operating instructions manual for “k” … pump/k_eng.pdf · operating instructions manual for...
TRANSCRIPT
1
Read Carefully ! ENGLISH Version
R1-04-08
O P E R A T I N G I N S T R U C T I O N S MANUAL FOR “K” DOSING PUMP
This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon.
Use of this pump with radioactive chemicals is for-bidden!
Keep the pump protected from sun and water. Avoid water splashes.
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
federico.renzi 21/05/2008
Progettato da Controllato da Approvato da Data
1 / 1 Edizione Foglio
Data
2
Danger!
GENERAL SAFETY GUIDELINES
In emergencies the pump should be switched off immediately! Disconnect the power cable from the power supply!
When using pump with aggressive chemicals observe the regulations concerning the transport and storage of aggressive fluids!
When installing always observe national regulations!
Manufacturer is not liable for any unauthorized use or misuse of this product that may cause injury, damage to persons or materials.
Caution!
“K” series solenoid dosing pumps comply with the following European regulations:
EN60335-1 : 1995, EN55014, EN50081-1/2, EN50082-1/2, EN6055-2, EN60555,3
Based on directive CEE 73/23 c 93/68 (DBT Low voltage directive) and directive 89/336/CEE (EMC Electromagnetic Compatibility)
Pump must be accessible at all times for both operating and servicing. Access must not be obstructed in any way!
Feeder should be interlocked with a no-flow protection device.
Pump and accessories must be serviced and repaired by qualified and authorized personnel only!
Always discharge the liquid end before servicing the pump!
Empty and rinse the liquid end before work on a pump which has been used with hazardous or unknown chemicals!
Always read chemical safety datasheet!
Always wear protective clothing when handling hazardous or unknown chemicals!
3
1. Introduction
Introduction: Metering Pumps “K” Series are the ideal solution for low / middle dosing of chemicals. All control and setup parameters are available through knobs and a visual system (led). Metering Pumps “K” Series have got an On/Off digital switch for ensure dosing activity (available only for some models).
Pump’s capacity
Flow rate is determined by the stroke length and by the stroke speed. The stroke length is adjustable from 0 to 100% using the stroke length adjustment knob. However dosing accuracy is guarantee within an adjustment range from 30% to 100%. The led on the frontal panel shows the activity status of the pump.
Models: KCO Constant pump with stroke speed (frequency) adjustment KCL Constant pump with level control, stroke speed (frequency) adjustment KIS Constant-proportional pump driven by external digital signal with level control: to each external pulse correspond one pump stroke KPV Constant-proportional pump driven by external digital signal with pulse divider mode (ratio 1 to 1000) and level control
KPVM Constant-proportional pump driven by external digital signal, level control , with pulse divider mode (ratio 1 to 100) and multiplier mode (ratio 1 to 10)
KIC Constant-proportional pump driven by current signal (0/4mA = 0 pulses; 20mA = max pulses) and level control
Capacity:
Pressure Flow bar l/h 20 01 18 02 15 04 10 05 08 08 05 10 02 18
Self venting capacity: Pressure Flow bar l/h 18 01 15 03 10 3.5 08 5.5 05 7.5 02 13
4
2. Unpacking
Included into package:
n.4 Dibbles ø6 n.4 Self tapping screws 4,5 x 40n.1 Fuse n.1 Foot filter with valve n.1 Injection valven.1 Level probe m 2 Delivery pipe* (PVDF) m 2 Suction pipe * (transparent PVC)m 2 Discharge pipe (transparent PVC)n.1 This installation manual
* If hose is 6x8 there is only a 4meters long hose. Cut to obtain suction and delivery hoses.
Remove the contents from the box.
PLEASE DO NOT TRASH PACKAGING. IT CAN BE USED TO RETURN THE PUMP.
5
3. Pump’s description
1 1
2 2
3 3
4 4
5 5
6 6
AA
BB
CC
DD
fede
rico.
renz
i21
/05/
2008
Prog
etta
to d
aCo
ntro
llato
da
Appr
ovat
o da
Dat
a
1 /
1 Ed
izio
neFo
glio
Dat
a
* S
trok
e le
ngth
Kno
b
Del
iver
y va
lve
to p
ower
sup
ply
Ext
erna
l Sig
nal i
nput
Leve
l pro
be in
put
Pum
p he
ad
* P
ress
to tu
rn.
To a
void
pum
p’s
dam
age,
tur
n th
e kn
ob
whe
n th
e pu
mp
is o
n.
to d
isch
arge
hos
e
6
4. Before to Install warnings
Pump’s installation and operativity is made in 4 main steps:
Pump’s installation
Hydraulic Installation (hoses, level probe, injection valve)
Electrical Installation (main power connection, priming)
Programming the pump.
Before to start, please read carefully the following safety information.
Protective clothes
Wear always protective clothes as masks, gloves, safety glasses and qfurther security devices during ALL installation procedure and while handling chemicals.
Installation location
Pump must be installed in a safety place and fixed to the table / wall to avoid vibration problems!
Pump must be installed in a easy accessible place!
Pump must be installed in horizontal position!
Avoid water splashes and direct sun!
Hoses and Valves
Suction and delivery hoses must be installed in horizontal position! All hoses connections must be performed using only hands’ force! No tongs required!
Delivery hose must be firmly fixed to avoid suddenly movements that could damage near objects!
Suction hose must be shorter as possible and installed in vertical position to avoid air bubbles suction!
Use only hoses compatibles with product to dose! See Chemical Compatibility Table. If dosing product is not listed please consult full compatibility table or contact chemical’s manufacturer!
7
5. Installation Draw
Pump must be installed in a stable support (for example a table) at a maximum height (from tank’s bottom) of 1,5 meters.
1 - Dosing Pump2 - Suction Hose3 - Delivery Hose4 - Injection Valve5 - Air discharge6 - Level Probe7 - Foot Filter8 - Power Cable
1
2
3
4
5
6
7
8
8
6. Hydraulic Installation
Suction Hose
Tightening Nut
Holding Ring
Pipe Holder
O-ring
Valve
Hydraulic connections are:
Suction Hose with level probe and foot filterDelivery Hose with injection valve
Discharge Hose
Suction Hose.
Completely unscrew tightening nut from pump’s head and remove assembling components: tightening nut, holding ring and pipe holder.
Assembly as shown in fig. (A). Insert hose into pipe holder until it reaches the bottom.
Lock hose on pump’s head by screwing down the tightening nut. Use only hands to do it!
Connect other side of the hose to the foot filter using the same procedure.
fig. (A)
9
6. Hydraulic Installation
Assembling foot filter with level probe.
Level probe must be assembled with foot filter using the provided kit. Foot valve is made to be installed into tank’s bottom without sediments priming problem.
Connect BNC from level probe into pump’s level input (front side of the pump). Put level probe assembled with foot filter into tank’s bottom.
Warning: If there is a mixer installed into tank, install a suction lance instead of level probe / foot filter.
Delivery Hose.
Completely unscrew tightening nut from pump’s head and remove assembling components: tightening nut, holding ring and pipe holder.
Assembly as shown in fig. (A). Insert hose into pipe holder until it reaches the bottom.
Lock hose on pump’s head by screwing down the tightening nut. Use only hands to do it!
Connect other side of the hose to the injection valve using the same procedure.
Progettato da Controllato da Modificato da, il Data
Edizione Foglio
/
076.0147.1
Massimo_F 24/10/2003
00
Toll. Gen.0.05
Materiale:
STEP 5
FILTRO DI ASPIRAZIONE CON SONDA DI LIVELLO - CONTATTO N.O.
FP+CE+PVDF
1 1
STEP 2 INSERT FLOATER
STEP 1 INSERT RING AS SHOWN
STEP 4 INSERT RING AS SHOWN
STEP 3
INSERT PROBEWITH N.O. CONTACT
UNTIL TO HEARA CLICK
10
6. Hydraulic Installation
Dicharge hose.
Insert one side of discharge hose into discharge connector as shown in fig (C).
Insert other side of discharge hose into product’s tank. During priming procedure product exceeding will flow into tank.
For priming procedure see the paragraph “Priming”.
fig (C)
Injection Valve.
Injection valve must be installed on plant from water’s input. Injection valve will open at pressure greater than 0,3bar.
Discharge knob
to suction hose
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
federico.renzi 10/04/2008
Progettato da Controllato da Approvato da Data
1 / 1 Edizione Foglio
Data
to delivery hose
to discharge hose
11
6. Hydraulic Installation
Self-venting pump head.
Self-venting pump head must be used when using chemicals that produce gas (i.e. hydrogen peroxide, ammonium, sodium hypoclorite at particular conditions).
Hoses assembling procedure (including purge hose) is described in fig. (A).
Notes:
- suction, delivery and purge valves are DIFFERENT! Do not exchange them!
- delivery and purge hoses are made of same material!
- it’s allowed to lightly bend discharge hose!
- during calibration procedure (“TEST”) insert discharge hose into BECKER test-tube!
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
federico.renzi 10/04/2008
Progettato da Controllato da Approvato da Data
1 / 1 Edizione Foglio
Data
to bleed hose
to suction hose
to delivery hose
12
7. Electrical Installation
All electrical connections must be performed by AUTHORIZED AND QUALIFIED personnel only. Before to proceed, please, verify the following steps:
- verify that pump’s label values are compatible with main power supply.
- pump must be connected to a plant with a differential switch (0,03A sensitivity) if there isn’t a good ground.
- to avoid damages to the pump do not install it in parallel with heavy inductance load (for example: engines). A relay switch must be used. See below picture.
P - Dosing Pump R - Relay
I - Switch or safety deviceE - Electrovalve or inductance load
A - Main Power
13
7. Electrical Installation
Once verified previous steps proceed as follows:
- check that “BNC” of level probe has been connected as described in “Hydraulic Installation” chapter.
- connect “BNC” and external signal to pump’s “INPUT” connectors.
1 Level probe input available on models: KIC, KIS, KPV, KPVM, KCL 2 External signal input available on models: KIC, KIS, KPV, KPVM
External Signal Input2
Level Probe Input1
14
LEVEL ALARM
CL, IS, IC, PV and PVM type pump are provided with a liquid level alarm to indicate product tank is empty. The level probe is connected to the right BNC plug on pump’s bottom panel. The level probe is made of a N.O. reed contact (10VA, 1A max., 230Vac max.) closed by a floating magnet housed in a (PP) plastic box. When the product level goes below the minimum the magnet closes the reed contact. The pump stops and the red LED on pump’s front panel indicates the alarm status.
PUMP TYPES
Pumps mod. “KCL” (12-24 Vac/Vdc), “KIC”, “KIS”, “KPV” and “KPVM” are equipped with a bicolour led.Led on, red colour: low level product alarm. Check product’s tank and restore the level.Led on, blinking green colour: pump normal operating mode.Led on, blinking green colour (one second on, one second off): power supply out of range. Check pump’s label and check the main power.
8. Models
15
KCO
Constant dosing pump with stroke speed adjustment between 0 and 100% of indicated capacity (see label on pump type). The % marked knob sets the pump capacity, changing linearly the magnet stroke number per minute. It is strongly suggested to not operate the pump in the range from 0 to 10%, since there is not a linear correlation with the pump stroke speed in that range. This pump is specially designed for constant dosing rates. KCO pump can be ON/OFF driven by a LPH or a LCD instrument. To set 2.5 l/h against 5 bar on a KCO 0505 the % marked knob should be set to 50%.
KCO has a divider (x- 0,1) to reduce by ten times the pump capacity by dividing the pump stroke speed. How to enable “divider mode”:- set the pump into OFF* mode;- keeping pressed the on/off button, wait 3 flashes from the status led. The pump will start the dosing activity with the stroke speed reduced ten times than the value set on stroke lenght knob. To disable the “divider mode”, power OFF the pump. Keeping pressed the on/off button, wait 3 flashes of the status led.
LEDThe led on the frontal panel shows the pump’s operating status through 5 flashing:
LED ACTIVITY PUMP’S STATUS
It flashes 3 times per second the pump is powered with a power supply lower than the label
It flashes 2 times per second the pump is powered with a power supply higher than the label
It flashes 1 time every 2 seconds the pump is in pause (OFF) and it is powered (OFF* mode)
led ON, it switches off when pump strokes
the pump is active and functioning (ON)
led ON, it switches off 1 time every 2 seconds
the pump is working into DIVIDE mode
ON/OFF button
status led
Stroke length adjustment knob
Stroke speed (frequency) adjustment knob
8. Models
16
kCL
Constant dosing pump with level alarm, provided with a floating magnetic sensor probe. A red led indicates that the pump stopped dosing because the product tank is empty. This pump has stroke speed adjustment between 0 and 100% of indicated capacity (see label on pump type). The % marked knob sets the pump capacity, changing linearly the magnet stroke number per minute. It is strongly suggested to not operate the pump in the range from 0 to 10%, since there is not a linear correlation with the pump stroke speed in that range.
kCL has a divider (x- 0,1) to reduce by ten times the pump capacity by dividing the pump stroke speed. How to enable “divider mode”:- set the pump into OFF* mode;- keeping pressed the on/off button, wait 3 flashes from the status led. The pump will start the dosing activity with the stroke speed reduced ten times than the value set on stroke lenght knob. To disable the “divider mode”, power OFF the pump. Keeping pressed the on/off button, wait 3 flashes of the status led.
8. Models
LED ACTIVITY PUMP’S STATUS
It flashes 3 times per second the pump is powered with a power supply lower than the label
It flashes 2 times per second the pump is powered with a power supply higher than the label
It flashes 1 time every 2 seconds the pump is in pause (OFF) and it is powered (OFF* mode)
led ON, it switches off when pump strokes
the pump is active and functioning (ON)
led ON, it switches off 1 time every 2 seconds
the pump is working into DIVIDE mode
LEDThe led on the frontal panel shows the pump’s operating status through 5 flashing:
ON/OFF button
status led
level alarm led
Stroke speed (frequency)
adjustment knob
Stroke length
adjustment knob
17
KIC
Proportional/constant pump driven by current signal. Setting the switch on the constant position the pump has stroke speed adjustment between 0 and 100% of indicated capacity (see label on pump type). The % marked knob sets the pump capacity, changing linearly the magnet stroke number per minute. It is strongly suggested to not operate the pump in the range from 0 to 10%, since there is not a linear correlation with the pump stroke speed in that range. Setting the switch on the proportional position the pump capacity is set proportionally to a given analog current signal; a given signal linear change will be followed by a linear change of capacity.The current signal accepted range is 0÷20 mA (it can be changed upon demand). The maximum pump capacity requested by the maximum input signal is set by the % marked knob. The IC pump can be driven by any electronic device (such as pH-meter, redox-meter, etc) that gives an analog current signal output. This signal must be applied to the bipolar cable provided with the pump, already internal connected, taking care of connections:
- red wire : positive (+)- black wire : negative (-)
8. Models
level alarm led
status led
Stroke length adjustment knob
Stroke speed (frequency)
adjustment knobON/OFF button
constant
proportional
18
8. Models
KIS
Proportional/constant pump driven by a digital signal.Setting the switch on the constant position, the pump has stroke speed adjustment between 0 and 100% of indicated capacity (see label on pump type). The % marked knob sets the pump capacity, changing linearly the magnet stroke number per minute. It is strongly suggested to not operate the pump in the range from 0 to 10%, since there is not a linear correlation with the pump stroke speed in that range. Setting the switch on the proportional position, to each external voltage free pulse correspond a magnet stroke. When proportional position is set, the % marked knob does NOT affect the pump capacity. IS proportional dosing pump can be driven by any external device (PCs, PLCs, etc) that produce a digital signal. The digital signal (N.O. contact) must be applied to the cable provided with the pump, already internal connected. If the digital signal is produced by an “Open Collector” transistor take care of connections:
- red wire : positive (+)- black wire : negative (-)
level alarm led
status led
Stroke length adjustment knob
Stroke speed (frequency)
adjustment knobON/OFF button
constant
proportional
19
KPV
Proportional/constant pump driven by a water meter digital signal. Setting the switch on the constant position, the pump has stroke speed adjustment between 0 and 100% of indicated capacity (see label on pump type). The % marked knob sets the pump capacity, changing linearly the magnet stroke number per minute. It is strongly suggested to not operate the pump in the range from 0 to 10%, since there is not a linear correlation with the pump stroke speed in that range. It is furthermore possible to divide the maximum magnet strokes per minute by 1, 10 and 100 using the switch on the front panel. Setting the switch on the proportional position, to each external pulse correspond one pump stroke. This pump can be driven by a CTFI or CWFI series water meters. This pump can also be driven by a digital signal coming from a voltage free contact. Driving signal is applied on the BNC plug on the left of the bottom pump cover. Dividing factor (N) value is obtained multiplying the indicated value on the adjustment knob by the multiplying switch (x1, x10, x100) value.
Capacity definition for “KPV” pump
Given the water m3 to be treated and the product amount to dose in p.p.m., the minimum pump capacity to be used can be obtained with the following formula:
ppm x K x m3
——————————————— = l/h1000
l/h - minimum pump capacity required ppm - product amount to dose in p.p.m. (gr/m3)
k - dosed product dilution factor (pure chemical k=1)m3 - maximum capacity of the system to be treated in m3 /h.
Dividing factor (N) to be set on the adjustment knob is given by the following formula:
imp/l x cc ( ———————————— ) x 1000 = N
ppm x K
N - is the number the external pulses are divided by to be set on the adjustment knobimp/l- pulse per liter given by the water meter
cc - pump’s single stroke dosing quantity (in cc). Refer to following tablek - dosed product dilution factor (pure chemical k=1)
ppm* - product amount to dose in p.p.m. (gr/m3)* 10.000 ppm equals to 1%
8. Models
20
Modello cc 2001 0.1 1802 0.19 1504 0.371005 0.460808 0.760510 0.93 0218 0.5
If the dividing factor (N), obtained with the above formula, is <1, a pump with higher single stroke dosing quantity is required or the water meter needs to be changed with one that gives higher number of pulses per liter. In some application this issue can be solved reducing the dosed product dilution factor. If dosed amount is higher than the needed one, the set dividing factor (N) can be increased.
8. Models
level alarm led
status led
Stroke length adjustment knob
Stroke speed (frequency)
adjustment knob
ON/OFF button
constant
proportional
selector (1, 10, 100)
21
KPVM
Proportional/constant pump driven by a water meter digital signal. Setting the switch on the constant position, the pump has stroke speed adjustment between 0 and 100% of indicated capacity (see label on pump type). The % marked knob sets the pump capacity, changing linearly the magnet stroke number per minute. It is strongly suggested to not operate the pump in the range from 0 to 10%, since there is not a linear correlation with the pump stroke speed in that range. It is furthermore possible to divide the maximum magnet strokes per minute by 1 (÷1), 10 (÷10) and 100 (÷100) using the switch on the front panel. The electronic capacity adjustment sets the injection per minute. Setting the selector on the proportional position and the selector on “multiplier” (X1), the pump gives a stroke each 10 external pulses sent. Setting the selector on “divider” (÷1 or ÷10), the pump gives at maximum a stroke each external pulse sent and at minimum a stroke each 100 pulses sent. This pump can be driven by a CTFI or CWFI series water meters. This pump can also be driven by a digital signal coming from a voltage free contact. Driving signal is applied on the BNC plug on the left of the bottom pump cover.
8. Models
level alarm led
status led
Stroke length adjustment knob
Stroke speed (frequency)
adjustment knob
ON/OFF button
constant
proportional
selector (1, 10, 100)
22
9. Priming
PRIMING
On the pump head there is a discharge hose (left side).
To prime the pump without touching the chemical proceed as follow:
1. connect the transparent hose to the discharge hose and insert its end into the chemical tank;
2. open the discharge valve turning the knob;
3. turn on the pump and set the stroke lenght adjustment knob on 100% and the stroke speed (frequency) adjustment knob on 100% (between 50% and 70% for high viscosity chemicals).
4. All air inside the pump will exit through the discharge valve. When the chemical begin to flow into discharge hose, close immediately the discharge knob.
If the chemical is particularly dense, to facilitate the priming:
1. turn on the pump and open the discharge valve;
2. insert a 20cc syringe into the discharge hose and suck;
3. when the syringe is near to full, close the discharge valve.
23
10. Troubleshooting
Problem Possible Cause
Pump doesn’t turn on.
Pump isn’t powered. Connect it to main supply.
Pump’s protection fuse is broken. Replace it. See page 26 for replacement procedure.
Pump’s main board is broken. Replace it. See page 26 for replacement procedure.
Pump is not dosing and solenoid is operating.
The foot filter is obstructed. Clean it.
Suction hose is empty. Pump must be primed. Repeat priming procedure.
Air bubbles inside hydraulic circuit. Check valves - hoses - fittings.
Product to dose is generating gas. Turn discharge knob and let air flow away.
Use a self-venting pump head.
Pump is not dosing and solenoid isn’t operating or slightly operating.
Crystals presence inside valves. Check them and try to dose 2-3 liters of normal water.
Change valves.
Injection valve obstructed. Change it.
24
11. Fuse and main board replacement
Fuse or main board replacement is allowed to qualified personnel only. Before to operate disconnect the pump from main power and all hydraulic connections.
For fuse replacement is necessary to use a 3x16 and 3x15 screwdriver and a new fuse (same model of old one).
For main board replacement is necessary to use a 3x16 and 3x15 screwdriver and a new main board (same model of old one).
Fuse replacement procedure:
- Turn pump’s injection knob on 0%.
- Remove 6 screws from pump’s back.
- Pull pump’s back cover until it’s completed separated from pump’s front. Be careful of the knob’s spring.
- Locate the blown fuse and replace it.
- Reassemble the pump. Be careful to put back the knob’s spring.
- Reinsert screws.
Main board replacement procedure:
- Turn pump’s injection knob on 0%.
- Remove 6 screws from pump’s back.
- Pull pump’s back cover until it’s completed separated from pump’s front. Be careful of the knob’s spring.
- Remove board’s screws.
- Completely disconnect wires from main board and replace it. Reinsert screws.
- Reconnect wires to the main board (see enclosed picture).
- Reassemble the pump. Be careful to put back the knob’s spring.
- Reinsert screws.
Model Fuse (Power supply Fuse (Power supply Pump “K” 230 VAC) 115 VAC) Kxx 2001 1A T 500mA T Kxx 1802 1A T 500mA T Kxx 1504 1A T 500mA T Kxx 1005 1A T 500mA T Kxx 0808 1A T 500mA T Kxx 0510 1A T 500mA T Kxx 0218 1A T 500mA T
25
12. Main Board
Mod. KCLMod. KCO
Solenoid
Fusibile
N
L
Mod. KPV / KPVM
Water meter
Mod. KIC / KIS
+ LevelInput
- +
External Signal
+ -
+ LevelInput
Solenoid SolenoidN
L
N
L
Fusibile Fusibile
Power supply
Power supply
Power supply
- LevelInput
- LevelInput
Interference suppression capacitor
Level
Solenoid
Power supply
N L
Fuse
+
Power supply
Power supply
26
A Appendix. Maintenance.
During normal operating mode, pump must be checked once for month. Wear needed safety devices and check hoses and all hydraulic components for:
- product leak
- broken hoses
- corroded connections
All maintenance operations must be performed by authorized and trained personnel only. If pump needs factory assistance please use original package to return it.
Before to do it, please, remove all dosing product inside the pump and hoses.
Use only original spare parts!
27
B Appendix. Construction Materials and Technical info
TECHNICAL FEATURES
Power supply: 230 VAC (190-265 VAC)Power supply: 115 VAC (90-135 VAC)Power supply: 24 VAC (20-32 VAC)Power supply: 12 VDC (10-16 VDC)
Pump Strokes: 0 ÷ 180Suction Height: 1,5 metresEnvironment Temperature: 0 ÷ 45°C (32 ÷ 113°F)Chemical Temperature: 0 ÷ 50°C (32 ÷ 122°F)Installation Class: IIPollution Level: 2Audible Noise: 74dbAPackaging and Transporting Temperature: -10÷+50°C (14 ÷ 122°F)Protection degree: IP 65
MANUFACTURING MATERIALS
Case: PP Pump head: PVDF, Acrylic, SS *Diaphragm: PTFEBalls: CERAMIC, PTFE, SS *Suction Pipe PVCDelivery Pipe: PVDF Valve Body: PP, PVDF, SS *O-ring: FP, EP, PTFE *Injection connector PVDF (ceramic, HASTELLOY C276 spring)Level Probe: PVDF *Level probe cable: PEFoot Filter: PVDF *as ordered.
INFORMATION
Flow cc per strokemax pressure
Min cc/h Max l/h Min GPH Max GPH Min Max
2001 29.16 1 0.008 0.26 0.03 0.09 20 bar 290 PSI
1802 61.56 2 0.016 0.53 0.06 0.19 18 bar 261 PSI
1504 118.8 4 0.031 1.06 0.11 0.37 15 bar 217 PSI
1005 151.2 5 0.040 1.32 0.14 0.46 10 bar 145 PSI
0808 237.6 8 0.063 2.11 0.22 0.74 8 bar 116 PSI
0510 302.4 10 0.080 2.64 0.28 0.93 5 bar 72 PSI
0218 540 18 0.143 4.76 0.50 1.67 2 bar 29 PSI
INFORMATION SELF VENTING MODELS
1801 29.16 1 0.008 0.26 0.03 0.09 18 bar 261 PSI
1503 86.4 3 0.023 0.79 0.08 0.28 15 bar 217 PSI
103,5 108 3.5 0.029 0.92 0.10 0.32 10 bar 145 PSI
085,5 162 5,5 0.043 1.45 0.15 0.51 8 bar 116 PSI
057,5 226.8 7.5 0.060 1.98 0.21 0.69 5 bar 72 PSI
0213 399.6 13 0.106 3.43 0.37 1.20 2 bar 29 PSI
28
C Appendix. Delivery Curves
Flow rate indicated is for H2O at 20°C at the rated pressure. Dosing accuracy ± 2% at constant pressure ± 0,5 bar.
Pump head I
bar
L/h
Pump head L
bar
L/h
Pump head L
bar
L/h
Pump head L
bar
L/h
Pump head L
bar
L/h
Pump head M
L/hbar
Pump head L
bar
L/h
29
C Appendix. Delivery Curves for self-purge pump head
Pump head LA
L/h
bar
Pump head LA
3.
3.
Pump head MA
3
3
Pump head LA
7.
7.
Pump head LA
3
3
L/h
bar
L/h
bar
L/h
bar
L/h
bar
Flow rate indicated is for H2O at 20°C at the rated pressure. Dosing accuracy ± 2% at constant pressure ± 0,5 bar.
30
D Appendix. Dimensions
bold
: m
m(
) :
inch
es
Dim
ensi
on
s1 1
2 2
3 3
4 4
5 5
6 6
AA
BB
CC
DD
222,
20 [
8,74
8]
138,00 [5.43]
61,0
0 [2
,402
]
157,60 [6.200]
96,2
8 [3
,791
]
91,0
0 [3
,583
]
46,65 [1.830]
31
Solenoid driven metering pumps are widely used to dose chemical fluids and it is important that the most suitable material in contact with fluid is selected for each application. This compatibility table serves as a useful help in this respect. All the informations in this list are verified periodically and believed to be correct on the date of issuance. All the informations in this list are based on manufacturer’s data and its own experience but since the resistance of any material depends by several factors this list is supplied only as an initial guide, in no way ATA makes warranties of any matter respect to the informations provided in this list.
Resistance rating Resistant 1 Fairly resistant 2
Not resistant 3
Materials Polyvinyldene fluoride PVDF Pump Heads, valves, fitting, tubing Polypropylene PP Pump Heads, valves, fitting, level floater PVC PVC Pump Heads Stainless steel SS 316 Pump Heads, valves Polymethyl Metacrilate (Acrylic) PMMA Pump Heads Hastelloy C-276 Hastelloy Injection valve spring Polytetrafluoroethylene PTFE Diaphragm Fluorocarbon (Viton® B) FPM Sealings Ethylene propylene EPDM Sealings Nitrile NBR Sealings Polyethylene PE Tubing
E Appendix. Chemical Compatibility Table
Product Formula Ceram. PVDF PP PVC SS 316 PMMA Hastel. PTFE FPM EPDM NBR PE
Acetic Acid, Max 75% CH3COOH 2 1 1 1 1 3 1 1 3 1 3 1
Hydrochloric Acid, Concentrate HCl 1 1 1 1 3 1 1 1 1 3 3 1
Hydrofluoric Acid 40% H2F2 3 1 1 2 3 3 2 1 1 3 3 1
Phosphoric Acid, 50% H3PO4 1 1 1 1 2 1 1 1 1 1 3 1
Nitric Acid, 65% HNO3 1 1 2 3 2 3 1 1 1 3 3 2
Sulphuric Acid, 85% H2SO4 1 1 1 1 2 3 1 1 1 3 3 1
Sulphuric Acid, 98.5% H2SO4 1 1 3 3 3 3 1 1 1 3 3 3
Amines R-NH2 1 2 1 3 1 - 1 1 3 2 3 1
Sodium Bisulphite NaHSO3 1 1 1 1 2 1 1 1 1 1 1 1
Sodium Carbonate (Soda) Na2CO3 2 1 1 1 1 1 1 1 2 1 1 1
Ferric Chloride FeCl3 1 1 1 1 3 1 1 1 1 1 1 1
Calcium Hydroxide (Slaked Lime) Ca(OH)2 1 1 1 1 1 1 1 1 1 1 1 1
Sodium Hydroxide (Caustic Soda) NaOH 2 1 1 1 1 1 1 1 2 1 2 1
Calcium Hypochlor.(Chlor.ted Lime) Ca(OCl)2 1 1 1 1 3 1 1 1 1 1 3 1
Sodium Hypochlorite, 12.5% NaOCl + NaCl 1 1 2 1 3 1 1 1 1 1 2 2
Potassium Permanganate, 10% KMnO4 1 1 1 1 1 1 1 1 1 1 3 1
Hydrogen Peroxide, 30% (Perydrol) H2O2 1 1 1 1 1 3 1 1 1 2 3 1
Aluminium Sulphate Al2(SO4)3 1 1 1 1 1 1 1 1 1 1 1 1
Copper-II-Sulphate (Roman Vitriol) CuSO4 1 1 1 1 1 1 1 1 1 1 1 1
32
F Appendix. Hoses resistance table
Hose features are very important for a reliable dosage. Every pump’s model is made to work in the best way using selected hoses according to pump’s capacity / model. Information reported here are intended for standard use only. For extended information ask to hose’s manufacturer.
33
G Appendix. “KCL” Installation drawing
5
6
7
8
9
4
2
1
3
1) Injection valve2) Delivery hose3) Safety breaker4) control panel
5) Power supply cable6) Outgassing hose
7) Suction hose8) Level probe
9) Foot filter
34
5
6
7
4
2
1
3
G Appendix. “KCO” Installation drawing
1) Injection valve2) Delivery hose3) Safety breaker4) control panel
5) Power supply cable6) Outgassing hose
7) Suction hose8) Foot filter
35
5
6
7
8 9
4
2
3
10
1
11
G Appendix. “KIC” Installation drawing
1) Injection valve2) Delivery hose3) Safety breaker4) Control panel
5) Power supply cable6) Outgassing hose
7) Suction hose8) Level probe
9) Foot filter10) pH-meter
11) Input signal (0-20mA)
36
7
8
9
4
2
1
3
10
5
6
G Appendix. “KPV” Installation drawing
1) Injection valve2) Delivery hose3) Safety breaker4) Control panel
5) Power supply cable6) Outgassing hose
7) Suction hose8) Level probe
9) Foot filter10) Pulse water meter
37
7
8
9
6
3
5
4
1
210
G appendix. “KIS” Installation drawing
1) Injection valve2) Delivery hose3) Safety breaker4) Control panel
5) Power supply cable6) Outgassing hose
7) Suction hose8) Level probe
9) Foot filter10) CCS or PLC instrument
38
NO
TIC
E: a
lway
s sp
ecify
the
pum
p’s
labe
l whe
n or
derin
g sp
are
part
s.
H appendix. Exploded view
1
2 5
4 3
10
13
27
30 29
14 15 16
17
18 19 20 32 25
26
31
28
21
39
L Appendix. Summary
Summary1. Introduction ........................................................................................................................................... 3
2. Unpacking ............................................................................................................................................. 4
3. Pump’s description ............................................................................................................................... 5
4. Before to Install warnings ..................................................................................................................... 6
5. Installation Draw .................................................................................................................................... 7
6. Hydraulic Installation ............................................................................................................................. 8
7. Electrical Installation ........................................................................................................................... 12
8. Models ................................................................................................................................................. 14
9. Priming ................................................................................................................................................ 23
10. Troubleshooting ................................................................................................................................ 24
11. Fuse and main board replacement .................................................................................................. 25
12. Main Board ........................................................................................................................................ 26
A Appendix. Maintenance. ...................................................................................................................... 27
B Appendix. Construction Materials and Technical info ......................................................................... 28
C Appendix. Delivery Curves .................................................................................................................. 29
C Appendix. Delivery Curves for self-purge pump head ........................................................................ 30
D Appendix. Dimensions ........................................................................................................................ 31
E Appendix. Chemical Compatibility Table ............................................................................................ 32
F Appendix. Hoses resistance table ...................................................................................................... 33
G Appendix. “KCL” Installation drawing .................................................................................................. 34
G Appendix. “KCO” Installation drawing ................................................................................................ 35
G Appendix. “KIC” Installation drawing .................................................................................................. 36
G Appendix. “KPV” Installation drawing ................................................................................................. 37
G appendix. “KIS” Installation drawing .................................................................................................. 38
H appendix. Exploded view .................................................................................................................... 39
L Appendix. Summary ............................................................................................................................ 41
40
When dismantling a pump please separate material types and send them according to local recycling disposal requirements.We appreciate your efforts in supporting your local Recycle Environmental Program.
Working together we’ll form an active union to assure the world’s invaluable resources are conserved.
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
federico.renzi 21/05/2008
Progettato da Controllato da Approvato da Data
1 / 1 Edizione Foglio
Data