The Aracve Alternave to Shingles ONDUVILLA ® Product Informaon Binder

Upload: others

Post on 05-Apr-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

The Attractive Alternative to ShinglesONDUVILLA®

Product Information Binder

Page 2: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

The Attractive Alternative to ShinglesONDUVILLA®

Table of Contents

Part 1Product Brochure

Part 2Color Samples

Part 3Installation Instructions

Part 4Additional Materials List

Part 5Sustainability

Part 6Test Results

Part 7Warranty Document

DIGITAL VERSION OF THIS DOCUMENT AVAILABLE AT:http://onduvilla-usa.com/onduvilla-documents.shtml

Page 3: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

The Attractive Alternative to ShinglesONDUVILLA®

Page 4: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA® is the perfect solution:n The premium look of tile at a cost similar to shingles

n A lifetime limited warranty

n Highest wind warranty in the industry. Material warrantied up to 150 mph winds

n Lightweight, time-tested design

n May be installed over shingles; no tear-off required

The Attractive Alternative to ShinglesONDUVILLA®

2

Developed by a world-wide company with 70 years of experience in the roofing materials industry.

Page 5: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA® delivers an attractive and distinctive appearance.

3

1

2

5

7

3

6

4

8

1 ONDUVILLA® Shingle

ONDUVILLA® System-Approved Fastener

Verge Piece

Slim Cap

2

3

4

Closure Cap

Foam Closure Strip (Eaves)

Foam Closure Strip (Ridge)

Apron (Option to #7)

5

6

7

8

ONDUVILLA® has a complete line of accessories

Page 6: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Elevate Roofing to New Dimensions™

4900 Ondura Drive, Fredericksburg, VA 22407Phone: 844.371.2345 FAX: 540.898.4991

onduvilla-usa.com©2016 Onduline North America, Inc. Printed in USA C-AF241C

Versatile Color Selection*

Beautify and protect your home with an ONDUVILLA® roofing system. Manufactured by Onduline, an established global leader in innovative residential roofing materials with 70 years of industry experience, ONDUVILLA® delivers superior weather protection and wind resistance compared to traditional shingles. When professionally installed, your ONDUVILLA® roofing system will withstand winds up to 150 miles per hour, guaranteed.

The Attractive Alternative to ShinglesONDUVILLA®

SLATE GRAY

FOREST GREEN

TERRACOTTA

EBONY BLACK

CLASSIC RED

SIENA BROWN

* Ask about availability of additional color options

4

Technology certified through laboratory and field tests.

Overlapping guides provide accuracy of nail zones during installation

Onduline®SealSmart™

SealSmart™ TechnologyONDUVILLA® protects your home from leaks with dual technology: Elastic composite material closes firmly around each nail to form a permanent seal, while two embossed ridges block rainwater from penetrating between shingles.

Eco ResponsibleONDUVILLA is committed to a small carbon footprint and supporting LEED construction requirements. All roofing materials are manufactured with recycled, organic fibers. These fibers form a strong but lightweight felt core, which means less energy consumption in transportation.

The ONDUVILLA manufacturing process is ISO 9001-certified and complies with the strictest standards and regulations.

Complete Accessory Line

Slim Cap Closure Cap Verge Piece Apron Piece

Ring-shanked Nail Fastener

Flashing Band Screw FastenerOndulair Slim

Standard Ridge ONDUVILLA® Flashing Adapter

Foam closure strips

Pipe Flashing

Page 7: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®The Attractive Alternative to Shingles

TERRACOTTA

Page 8: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®The Attractive Alternative to Shingles

CLASSIC RED

Page 9: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®The Attractive Alternative to Shingles

FOREST GREEN

Page 10: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®The Attractive Alternative to Shingles

SIENA BROWN

Page 11: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®The Attractive Alternative to Shingles

SLATE GRAY

Page 12: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®The Attractive Alternative to Shingles

EBONY BLACK

Page 13: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®The Attractive Alternative to Shingles

TUSCANY RED

Page 14: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

11

ONDUVILLA®

I N S T A L L A T I O N I N S T R U C T I O N S

The Attractive Alternative to Shingles

Page 15: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

2

Even though ONDUVILLA® is easy to install, it is important to read through these instructions to understand how they apply to your roof. ONDUVILLA®, like all roofing materials, should be carefully installed. Take your time and closely follow these installation guidelines. If you require additional assistance, please feel free to call our support team at 800.777.7663 and one of our associates will be happy to help.

INSTALLATION INSTRUCTIONS

Warranty protection is only applicable when ONDUVILLA® shingles have been installed using ONDUVILLA® specific installation guidelines.

GENERAL INSTRUCTIONS: This guide addresses basic roofing practice and commonly occurring roof details for the installation of ONDUVILLA®. For additional information and details please call 800.777.7663 to speak with a representative or refer to the website, onduvilla-usa.com.

Consult state and local code requirements prior to installation. Follow all OSHA and governmental safety requirements during installation.

ROOF DECKS: Use minimum 3/8” (10mm) plywood or OSB decking as recommended by APA-The Engineered Wood Assn. (Refer to local code on framing and sheathing minimum requirements).

SLOPE: 2:12 minimum. For 2:12 up to 4:12, a double layer of underlayment is required. For 4:12 or greater, a single layer is required.

UNDERLAYMENT (LEAK BARRIER): Install ice and water leak barrier at the eaves in localities where leaks may be caused by water backing up behind ice or debris dams. Consult state and local code for minimum requirements.

UNDERLAYMENT (ROOF DECK PROTEC-TION): Underlayment is primarily used to separate a roof covering from the roof deck, shed water, and provide secondary weather protection for the roof area of the building. Install a minimum of one layer of ASTM D226, Type I No. 15 asphalt-saturated felt applied horizontally in shingle fashion integrated with ice and water leak barrier as required by code. Refer to manufacturer’s installation guidelines and fastening requirements. Synthetic underlayment can be substituted for No. 15 asphalt-saturated felt. Consult manufacturer for suitability and installation requirements.

FASTENERS: Use only ONDUVILLA® approved fasteners to attach shingles and accessories. Over driving fasteners will damage the shingle as well as create alignment issues of corrugations. Raised fasteners will interfere with the sealing of the shingle. Unless otherwise noted, shingle fasteners should be placed at apex of each corrugation and centered between the two overlapping guides.

VENTILATION: For optimal shingle life and to help prevent moisture issues, all roof structures must have proper ventilation to prevent entrapment of moisture-laden

air behind roof sheathing. Ventilation must be designed to meet or exceed current state or local code minimum requirements.

FLASHING: Corrosion-resistant flashing must be installed at wall and roof intersections, at gutters, whereever there is a change in roof slope or direction, and around roof penetrations to help prevent leaks.

The darker shaded area of the shingle should be placed at the top.

For correct overlap take care that overlapping guides of upper and lower shingles are aligned.

Only use ONDUVILLA® fasteners for shingles and accessories.

Fasten between overlapping guides unless otherwise noted in guidelines.

When using Closure Strips, position so that fasteners penetrating the shingle also pass through the closure strip.

Please use extreme caution on the roof to insure your personal safety at all times. Be sure that ladders and other such devices are safely positioned and properly secured. OSHA recommends the use of a safety harness when applying roofing. Protective eyewear is recommended when applying fasteners or using power tools. When walking on ONDUVILLA®, wear soft-soled shoes and place your feet on the flat area of the shingle. All roofing is slippery when wet, dusty, frosty or oily...avoid working or walking on the roof if any of these conditions exist. Working on the roof if windy conditions exist can be dangerous and should be avoided. And, like any asphalt product, refrain from walking on in high heat.

IMPORTANT SAFETY INFORMATION

Page 16: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

3

TABLE OF CONTENTS

Supporting structure ............................................................... 4Minimum pitch ........................................................................ 4Materials checklist ................................................................... 4Installation principles .............................................................. 5Fastening ................................................................................. 5Eaves ........................................................................................ 6Ridge for pitch below 10/12 .................................................... 7Ridge for pitch above 10/12 .................................................... 7Hip ........................................................................................... 8Valley ....................................................................................... 9Hips to ridge .......................................................................... 10Verge ..................................................................................... 10Sidewall ................................................................................. 11Headwall ................................................................................ 11Mono ridge to wall ................................................................ 12Ventilation ............................................................................. 13SPECIAL APPLICATION: ONDUVILLA® Flashing adapter .........14ONDUVILLA® System Diagram ...............................................15Accessories ............................................................................ 16

Page 17: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

4

Detailed ONDUVILLA® installation guide

SUPPORTINg STRUCTURE

MINIMUM PITCh: 2/12 FOR SOLId dECk

ONDUVILLA® can be installed on all standard roof structures.

Wooden deck (for example OSB)

ONDUVILLA® Fasteners

n Hammern Screw gun/screw drivern Measuring tapen Saw

n Utility knife n Safety gogglesn Chalk line

MATERIALS ChECkLIST

For residential applications, ONDUVILLA® should be installed over solid decking—usually plywood, wood boards, OSB, or planks—with a proper underlayment (felt).

Slope = amount of rise per runExample: 3-in rise per 12-in run = 3:12

Minimum slope required: 2:12

Run

RiseSlope

Ridge

Eave

Page 18: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

5

INSTALLATION PRINCIPLES

FASTENINg

Start installation at eave. Overlap joints away from entrances and/or away from the point of greatest traffic. This will improve overall appearance.Position the dark strip “shadow line” at the top. Stagger each course at least one corrugation from previous piece. Different visual effects can be created by various staggers of 1, 2, or 3 corrugations. Ensure proper waterproofing by aligning the overlapping guides.

ONDUVILLA® is to be fastened at each overlap and corrugation with ONDUVILLA® Fasteners. Fasten the shingles following the order described, between the 2 overlapping guides. Do not fasten those corrugations that will be overlapped by the next shingle or Verge Piece until those pieces are in place.

Over fastened

Ok

Deformed

Overlappingguides

Half shingle6

Full shingle5

Half shingle3

Full shingle1

Full shingle4

Full shingle2

Dark strip positioned on the top 3D effect

X

1

X

1

3

1

3

4

2

4

5

X

2

2 X

X

1st Course-Start at either rake, shingle can be installed in either direction over properly prepared and installed sheathing, underlayment, ice and water leak barrier, and edge trim. Begin by installing first full shingle. Install shingle at rake positioning so that Verge Piece aligns with first corrugation on shingle. You may need to inset shingle 1/4” to 1/2” in order to align first corrugation with Verge Piece. If necessary overhang shingle no more than 1-1/2” over eave and drip edge trim. Closure Strips should be used to close corrugations. Fasten according to the fastening pattern in the fastening schedule. On first course, fasten above the upper alignment line to ensure penetration into the roof deck. Install additional shingles along eave by overlapping one corrugation and continue following fastener schedule to the opposite rake.

2nd course- Stagger each course a minimum of 1 corrugation from the previous course by cutting the shingle. Preferred method is to alternate full shingle first course and half shingle second course and continue alternating pattern. Align at the rake edge as before. Align the overlapping guide with the underlying shingle and fasten according to the fastener schedule. Continue installing to the rake edge. Continue up slope with additional courses as needed. Make sure that shingles are aligned correctly and running true following the desired stagger pattern. Make sure fasteners are not over driven as it will cause the shingle to deflect and not overlap correctly.

Page 19: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

6

Drive fasteners on top of the corrugations between the overlapping guides

At eaves drive fasteners on top of the corrugations above the overlapping

guides

Closure Strips

12.5”

To be

staggered

10.625”

EAvES

Leave a space of 1/4’’ between the first corrugation and the rake line in order to provide for the correct fastening of the Verge Piece. (See Verge section on page 10.)

Shingles can be temporarily fastened using blind nailing method with standard roofing nails. Nail top of shingle in flat area between alignment guides with roofing nails following alignment and overlap install guidelines. Make sure temporary fastener is flush with shingle. Install ONDUVILLA® Fasteners as recommended.

Underlayment

Roof Deck (OSB)

Shingle can overhang 1’’ to 1-1/2”

Page 20: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

7

RIdgE FOR PITCh BELOw 10/12

1 The Apron Piece is installed on both sides of the roof to secure watertightness. At the verge, the Apron Piece has to be cut on site parallel to the last corrugation of the shingle.

2

At low pitches (below 4/12), soft fastening is recommended in order to avoid the possible deformation of the Slim Cap.

5 Foam closures can be fastened below the ridge piece, in order to prevent birds or other animals from entering the roof space.

6Install Closure Strips. Install Slim Cap over Apron Piece maintaining proper overlap and fastening schedule.

4

For pitches above 8/12, it is necessary to cut the flat part above the corrugations.

3

RIdgE FOR PITCh ABOvE 10/12

The Slim Cap can be used for pitches up to 10/12. Above that limit, the Standard Ridge piece should be used.

Verge Piece

1 Install Closure Strips. Install ridge fastening through corrugations.

Closure Strips

Standard Ridge piece

2

Gap for ventilation

Gap for ventilation

Cut the Apron Piece

Verge PieceVerge Piece

Gap for ventilation

Overla

p

Overlap

Slim Cap

Apron Piece

Soft �xing

Closure Cap

Slim Cap

Run shingles to ridge. Leave gap for ventilation if desired.

Closure Strip

Page 21: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

8

hIP

Carefully cut shingles maintaining proper gap for ventilation.

Apply Flashing Band for the first 3’ of hips and then ONDULAIR SLIM membrane for rest of hip.

1 2

Fix the Slim Cap and Closure Cap always on top of the corrugations of ONDUVILLA® shingles. As per the ridge, soft fastening is recommended at low pitches.

3

Closure Cap

ONDULAIR SLIM Perforated aluminum self-adhesive tape, which provides additional water tightness and assists in the ventilation at hips and ridges.

Page 22: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

9

vALLEY

Fillers cut from Closure Strips

Underlayment

Metal valley

Roof deck (OSB) 10” 10”

Ice and water shield

Roof deck (OSB)

Center full width of ice and water leak barrier in valley directly over sheathing. Install a minimum of 20” wide metal valley over ice and water leak barrier in 8’ to 10’ sections in shingle fashion overlapping a minimum of 6”. Preformed “w” style valley is preferred. Secure every 24” o.c. with cleats or large head nails. Seal nail heads with compatible sealant and run shingle underlayment. Install shingles, trimming to leave open valley. Install closure pieces to close corrugations, carefully fastening shingles to minimize penetrating metal valley.

Page 23: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

10

hIPS TO RIdgE

Secure the watertightness of the detail by applying self adhesive flashing material (Flashing Band.)

Apply a module consisting of 2 Slim Cap portions (to be fastened together using Flashing Band), cutting them at the right angle in accordance with the slope of the roof.

At the beginning of the roof, the Verge Piece simply overlaps the first corrugation of ONDUVILLA®.

In addition to the usual fastening on top of the corrugation, side fastening is also necessary to ensure against wind uplift. Side fastening comes first, then finalize with top fastening.

On the opposite side, the roof may not end with a corrugation. Cut shingle and install a 1” x 1” batten. Bend shingle onto batten and fasten the Verge Piece through the batten.

Cut the Slim Cap with an angle of 45° and fasten it. The ridge piece has to overlap the hips.

Overlappingstripes

Top fastening

Side fastening

Verge Piece

Flashing Band

Apron PieceApprox. 15-3/4”

45°

vERgE

2.4”

Gable end

1 2 3

1 2

2

1

3

Slim Cap

Slim Cap

Page 24: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

11

Install ice and water leak barrier directly to sheathing and 4” up sidewall. Run shingle to the sidewall and trim to fit. Install metal flashing over last corrugation and onto ice and water leak barrier on sidewall. Fasten through metal and shingle corrugation and fasten flashing to sidewall. Flash top edge of metal on sidewall with self-adhesive flashing tape making sure to correctly shingle flashing, weather resistant barrier and cladding over metal flashing.

SIdEwALL METhOd 1

SIdEwALL METhOd 2

Install ice and water leak barrier to sheathing and 4” up sidewall. Install metal J channel a minimum of 4” up sidewall. Throat of metal J channel should be wide enough for last shingle corrugation to terminate into channel. Fasten through corrugation and ice and water leak barrier making sure not to fasten through metal J channel. Properly shingle metal J channel on side wall with weather resistant barrier and exterior cladding.

hEAdwALL

Run ONDUVILLA® shingles up slope to wall. Install Apron Piece on shingles at wall. Install Flashing Band and/or flashing metal, sealing top edge of Apron Piece to wall. Install wall covering over Flashing Band and top of Apron Piece.

Page 25: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

12

MONO RIdgE TO wALL

2 Apply a Standard Ridge piece and fasten it on both sides.

1 Install the Verge Piece. Install Closure Strips.

Verge Piece

Closure Strips Universal Ridge

Page 26: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

13

vENTILATION

Locate and position roof vent as recommended by manufacturer. Run shingles up slope to the desired location of vent.Position ONDUVILLA® Flashing Adapter with corrugations overlapping shingle. Use vent template to mark and cut out opening for vent in sheathing and the ONDUVILLA® Flashing Adapter. Make sure flange on the vent fits on the flat area of the adapter. Install vent per manufacturer’s recommendations setting vent flange in a continuous bead of compatible sealant.With vent in place, cut flat section of upper ONDUVILLA® Flashing Adapter to go around the throat of the vent. Where adapters overlap, run two parallel beads of sealant. Make sure to maintain proper overlap and alignment of adapter consistent with the shingles. Continue running shingles maintaining proper alignment and overlap.

All roofs require proper ventilation. This illustrates how to install a power vent.

Page 27: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

14

SPECIAL APPLICATION: ONdUvILLA® FLAShINg AdAPTER

Custom metal along bottom of curb and onto adapter. A: Bend metal flashing that will provide a minimum of 4’’ of coverage on the deck and 4’’ continuing up the wall of the curb/chimney. B: Install and seal corners and areas that will be overlapped as needed.

2

Placing adapter at base of curb, chimney, etc. A: Install shingles up to a maximum of 1 shingle height or 16’’ away from the curb base. B: Place adapter so that one full corrugation is on each side of the curb. C: Notch the flat portion of the adapter in order to keep it in line with the corresponding course of shingles. If curb is wider than 1 adapter, then a combination of 2 or more can be used. One adapter can be used on curb widths of up to 18’’; each additional adapter will add 24’’ of usable length.

1

Metal pan along sides of curb. A: Bend custom metal pan flashing to extend up the curb a minimum of 4’’ (if possible 6’’ is recommended). Metal should have a base that allows a 1/2’’ return to remain vertical under the first corrugation away from the curb. This pan will run from 6’’ beyond the top of the curb to 4’’ below the bottom corner. B: Cut and bend the metal at the corners to provide a water tight seal. C: At the overlaps, a seal should be applied to provide adequate protection. This should be repeated for each side of the curb.

3

Install back metal pan. A: Bend a metal pan that will correctly overlap aforementioned side pans and provide a minimum of 4’’ up the backside of the curb/chimney and a minimum of 12’’ on the deck. B: Install shingles and Closure Caps along back in such a way as to provide a minimum of 3’’ of non-covered flashing and a minimum of 6’’ clearance between fasteners and the backside of the curb/chimney.

4

The ONDUVILLA® Flashing Adapter can be used in a variety of locations on the roof in order to provide proper water tightness. This may include chimneys, ventilators, skylights or other roof penetrations.

Page 28: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

15

ONDUVILLA ® has everything you need all in one comprehensive solution! All visible accessories are designed with the same shingle material, including the ridge, hip and gable end. And you can benefit from a wide range of smart, functional accessories to deliver a professionally installed roof.

A complete system for a professionally installed roof

ONDUVILLA®, a complete roofing system

1

2

5

7

3

6

4

8

1 ONDUVILLA® Shingle

ONDUVILLA® System-Approved Fastener

Verge Piece

Slim Cap

2

3

4

Closure Cap

Foam Closure Strip (Eaves)

Foam Closure Strip (Ridge)

Apron (Option to #7)

5

6

7

8

Page 29: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

16

Elevate Roofing to New Dimensions™

4900 Ondura Drive, Fredericksburg, VA 22407Phone: 800.777.7663 FAX: 540.898.4991

www.onduline-usa.com©2015 Onduline North America, Inc. Printed in USA K-AE263

PROdUCT dESCRIPTION dIMENSIONSM

OLd

Ed A

CCES

SOR

IES

Slim Cap Cap for ridge and hips, for roofs with a pitch up to 10/12. 41-1/2 x 7’’

Closure Cap Designed for the finishing of ridge and hip lines (pitch up to 10/12. 42 x 7’’

Apron Piece

Designed to provide watertightness and ventilation to the ridge line (Residential), for roofs with a pitch up to 8/12. Can also be used to seal the gap between ONDUVILLA® shingles and vertical wall abutment.

40-1/2 x 5-1/2’’

Verge PieceDesigned to provide a neat weatherproof seal at the edge of the roof. Can be used for both sides right/left.

41 x 4 x 4-1/2’’

OTh

ER A

CCES

SOR

IES

Standard RidgeUniversal solution for ridge and hip. Does not require additional waterproofing device. (ONDULAIr SLIM or foam Closure Strips recommended.)

35-1/2 x 19-1/2’’

ONDULAIr SLIMPerforated aluminum self-adhesive tape, which provides additional water tightness and assists in the ventilation at hips and ridges.

6” x 16’

Flashing BandAluminum self-adhesive flashing band with butyl adhesive, used for waterproofing around chimneys, walls, skylights and other abutments or transitions. No special tools required.

98 x 11-3/4”

Pipe FlashingPipe Flashing accessory used for cold or hot pipes protruding through roof. Can be used for other roof penetrations.

19-1/2 x 25” and 26-1/2 x 33’’

ONDUVILLA® Flashing Adapter

The ONDUVILLA® Flashing Adapter can be used in a variety of locations on the roof in order to provide proper water tightness. This may include chimneys, ventilators, skylights or other roof penetrations.

16 x 42”

Closure StripsAvailable in two styles: Vented or solid. Solid closure strips should be used whenever a watertight seal is necessary.

38 x 1 x 1”

ONDUVILLA® Screws Zinc-plated steel, Phillips head screw with EPDM washer. Color matched with ONDUVILLA colors. 2-7/8”

ONDUVILLA® Nails Galvanized steel, ring-shank nail with EPDM washer. Color matched with ONDUVILLA colors. 3” and 4”

Available in 6 designer colors

SLATE gRAY

FOREST gREEN

TERRACOTTA

EBONY BLACk

CLASSIC REd

SIENA BROwN

For more assistance with how to install an ONDUVILLA® roof, go to onduvilla-usa.com.

Page 30: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®

The Attractive Alternative to Shingles

Additional Materials Required for Onduvilla Roof Installation

n Pipe Flashingswww.oatey.com/products/flashings/roof-flashings/retro-master-flash-roof-flashings or similar

n Valley Metal http://www.qualityedge.com/w-valley/ or similar with a minimum of 10 inches of flashing on each side of the valley.

n Flashing Metal (when not using Flashing Tape) The use of copper, 28 gauge clad steel, or a minimum of .019 coated aluminum is recommended. When using metal flashing it will have to be custom formed onsite.

n Self-Adhered Underlayments (for use along eaves, valleys or as local building code requires)https://grace.com/construction/en-us/roofing-underlayments/Grace-Ice-And-Water-Shield or similar is recommended

n UnderlaymentsMinimum of ASTM D226 Type II 30lb felt. Synthetic underlayments can be used but will void a class C fire rating.

n Drip Edge (Installed along the eaves or gutter line)http://www.qualityedge.com/perimeter-edge-flashing/ or something similar to the F8 or Asphalt Drip options shown is recommended.

n Sealant (for use at areas where Onduvilla meets metal)http://us.henry.com/roofing/mastics-and-cements/209-extreme-wet-patch-roof-leak-repair/

or similar

Page 31: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®

The Attractive Alternative to Shingles

A Real Commitment to Sustainability

Our group values completely integrate sustainability

Onduline is committed to sustainability from the beginning to the end of the value chain:

A sustainable solution...

n Light weight

n Integrates recycled materials

n Eco-responsible process

n Designed to be easily and quickly installed

...improves building sustainability...

n Light weight roof, thus lighter support structure for building

n Easier transport and manipulation

n Fast installation

n Shared knowledge through training of building professionals

...and owner well being

n Faster use of the building

n Safety and protection

n Thermal and acoustical comfort

Page 32: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®

The Attractive Alternative to Shingles

Our Objectives

n Provide well-being and comfort to end users for them to enjoy any weather

n Be recognized as a Green Solution by accredited organizations

Through the 3 dimensions of sustainability:

n Enable more business opportunities for our partners

n Support economic growth

n Keep improving our manufacturing process

n Offer environmentally- friendly solutions

n Contribute to people’s progress

n Share know how

n Provide comfort to end users

Environment Economy

People

Page 33: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®

The Attractive Alternative to Shingles

Onduline offers solutions to protect people from any environment, from any weather, but also returns the favor to the environment with sustainable processes and products:

n Onduline’s carbon footprint presents 4066 g CO2/m2, the lower rate for our category

n Eco-responsible production — Plants 14001 certified, with a clear environmental management system

— Clean production process: closed water circuit, low energy use, no dangerous waste, recycling systems for gaseous emissions

— Use of natural pigments for coloration

— About 200,000 tons of material recycled each year

n Sustainable solutions — Asbestos free solutions always

— Light weight solutions, easy to carry and install (saves energy, transport costs; enables lighter structures or less concrete)

— Solutions that are designed to be quickly built, offering fast & reliable protection from rain

— Re-roofing solutions to avoid additional waste

— Acoustical and thermal comfort for the well-being of the end users

Page 34: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®

The Attractive Alternative to Shingles

n Onduline plays an important role in economic development of more than 100 countries on the 5 continents

Onduline is a company that values its workers and respects the highest standards for the entire chain

n Cultural diversity: about 1600 people in 42 subsidiaries all around the world, 42 nationalities to be close to each market

n Shared knowledge and experience: training sessions to provide local people with necessary skills to install our systems and build their house or develop their business. 2016: more than 20,000 people trained in emerging countries

Page 35: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®

The Attractive Alternative to Shingles

Certifications and Awards

Environmental Product Declaration (EPD): We are the first company who applied for an EPD for our bitumen corrugated product family. We thus created a Product Category Rule for Roofing and Wall Cladding (PCR) that will be the basis for all future EPD’s for all suppliers.

IBU (Institut Bau und Umwelt) / PE International, February 2013

Positive recognition and endorsements from industry organizations

Onduline’s carbon footprint: 4066 g CO2/m2. Our products are least emissive products, compared to other roofing solutions.

Pur Projet, March 2011

Recycled content: Onduline has received a VAR Confirmation report (VAR 1016) to process the recycled content of its solutions.

ICC-ES, June 2011

Max Feffer Culture & Sustainability Center in Brazil, recognized worldwide as an example of sustainable building, covered with ONDULINE® and ONDUCLAIR® solutions

Anamaco Prize in Brazil. Anamaco (association of all construction material retailers of Brazil) organizes research to reveal the most well known brand in many categories. Onduline got first place in the category “ecological tiles.”

Page 36: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA®

The Attractive Alternative to Shingles

Green Seal of Falcão Bauer in Brazil, a well known Brazilian construction material laboratory. This seal attests that we use 50% of recycled material for our products.

Onduline, member of “Ponto Verde”, a green society that recycles packaging wastes.

Onduline, member of “GECORPA” (Building resoration association) and ICOMOS PORTUGAL, both defend the “green building” concept.

ISOLINE recognized as “Green Product” by Malaysia Green Building Confederation (MGBC).

Onduline is member of National Green Building Councils in India and Indonesia, and Russia

Launch of a Green Roofing Award in Indonesia, in partnership with the Green Building Council Indonesia and other local associations

Russia: Eco-houses: Houses built with wood, insulated with straw and covered with Onduline (official supplier)

http://www.i-freedom.ru/

Page 37: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report.

Copyright © 2013 Page 1 of 4 1000

ICC-ES Evaluation Report DRAFT ESR-1957 Reissued May 1, 2013 This report is subject to renewal June 1, 2015.

www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ®

DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION

Section: 07 41 00—Roof Panels REPORT HOLDER: OFIC NORTH AMERICA INC. 4900 ONDURA DRIVE FREDERICKSBURG, VIRGINIA 22407 (800) 777-7663 www.ondura.com EVALUATION SUBJECT: ONDURA®/DURACOR® CORRUGATED ASPHALT ROOFING SHEET AND ONDURA®/DURACOR®, ONDUVILLA®, AND ONDUVILLA® FR CORRUGATED ASPHALT ROOFING TILE 1.0 EVALUATION SCOPE

Compliance with the following codes: ! 2015, 2009 and 2006 International Building Code® (IBC)

! 2015, 2009 and 2006 International Residential Code® (IRC)

Properties evaluated: ! Weather protection

! Wind resistance

! Durability

! Fire classification

2.0 USES

Ondura®/Duracor®, Onduvilla®, and Onduvilla® FR Corrugated Asphalt Roofing Sheet and Tile are used as either Class A, Class C or as nonclassified roof coverings when installed in accordance with this report.

3.0 DESCRIPTION

3.1 Ondura®/Duracor® Corrugated Asphalt Roofing Sheet:

A corrugated asphalt roofing sheet consisting of corrugated sheeting made from processed mineral and organic fibers and impregnated with bitumen (asphalt). The sheets are nominally 49 inches wide by 783/4 inches long by 0.123 inch thick (1245 by 2000 by 3.1 mm) and have a nominal

finished weight of 0.68 pound per square foot (3.32 kg/m2). The sheets have 13/8-inch-deep (35 mm) corrugations spaced at 4 inches (102 mm) on center, continuous along the length. The exposed surface is factory-finished with a paint surface coating in one of eight colors - white, tan, blue, black, brown, gray, red or green. 3.2 Ondura®/Duracor® Corrugated Asphalt Roofing

Tile: A corrugated asphalt roofing tile that is identical to the sheet described in Section 3.1, with the exception that the tiles are 193/4 inches long (502 mm).

3.3 Onduvilla® and Onduvilla® FR Corrugated Asphalt Roofing Tile:

Onduvlla® and Onduvilla® FR corrugated asphalt roofing tiles consist of corrugated sheeting made from processed mineral and organic fibers and impregnated with bitumen (asphalt). The sheets are nominally 15 ¾ inches wide by 42 inches long by 0.114 inch thick (400 by 1070 by 2.8 mm) and have a nominal finished weight of 0.60 pound per square foot (2.93 kg/m2). The sheets have 1 ½ -inch-deep (38 mm) corrugations spaced at 7 ½ inches (191 mm) on center, continuous along the length. The exposed surface is factory-finished with or without a paint surface coating in one of six colors – terracotta 3D, classic red 3D, forest green 3D, siena brown, slate grey, or ebony black. 3.4 Fasteners: OFIC nails used for installation of OFIC Ondura®/Duracor® sheets, and Ondura®/Duracor®, Onduvilla® and Onduvilla® FR tiles are ring-shanked type, fabricated from ASTM A 510, Grade 1006 or 1008, steel wire, with mechanically deposited zinc coating to a thickness of 2.0 mils [0.002 inch (0.05 mm)]. The nails have a 0.135-inch (3.4 mm) shank diameter and a 7/16-inch (11.1 mm) head diameter.The nails have a 1/8-inch-thick-by-5/8-inch-diameter (3.2 by 15.9 mm) EPDM rubber washer attached below the nail head. Nails are a minimum of 2 ¾-inch-length (70 mm) for ½ inch (12.5 mm) penetration into code complying sheathing. Screws of minimum a 0.135-inch (3.4 mm) shank diameter and a 7/16-inch (11.1 mm) head diameter with greater than inch (12.5 mm) penetration into code complying sheathing are approved for use when installed in accordance with

Page 38: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ESR-1957 | Most Widely Accepted and Trusted Page 2 of 4

Section 2.1.3 of this report..

3.5 Ridge Caps: A wide ridge cap and a narrow ridge cap are manufactured from the same material as the sheet and tile, without the corrugations. Both ridge caps are 783/4 inches length (2000 mm), with the wide ridge cap having a width of 19 inches (483 mm) and the narrow ridge cap having a width of 121/2 inches (318 mm).

4.0 DESIGN AND INSTALLATION 4.1 General: Installation of the corrugated asphalt roofing sheets and Tiles must comply with this report and the manufacturer’s published installation instructions. The manufacturer’s published installation instructions must be available at the jobsite at all times during installation.

The roofing sheets and tiles must be installed on roofs with a minimum slope of 2:12 (17 percent). The sheets and tiles must be installed over solid or closely fitted, minimum 15/32-inch-thick (11.9 mm) exterior grade plywood complying with U.S. DOC PS-1 or PS-2, or 7/16-thick (11.1 mm) OSB sheathing complying with U.S. DOC PS-2, covered with a minimum of one layer of asphalt-saturated felt underlayment complying with ASTM D 226, Type II (No. 30), except where roof fire classification is required. This installation should be done in accordance with Section 4.2 of this report.

In areas where there has been a history of ice forming along the eaves, causing a backup of water, an ice barrier must be provided in accordance with 2009 IBC Section 1507.5.4, 2006 IBC Section 1507.5.3 or IRC Section R905.4.3.1. The ice barrier must extend from the eave to a distance of at least 24 inches (610 mm) inside the exterior wall line of the building.

The sheets and tiles must be installed with a minimum side lap of one corrugation. The minimum end (head) lap must be 7 inches (178 mm) for Ondura®/Duracor® sheets. The minimum end (head) lap must be 5 ¾ inches (146 mm) for Ondura®/Duracor® tiles. The minimum end (head) lap must be 3.5 inches (89 mm) for Onduvilla®, and Onduvilla® FR tiles. Ridge caps, hip covers and valley flashing must be installed in accordance with the manufacturer’s published installation instructions. Other flashing must be installed in accordance with IBC Section 1503.2 and IRC Section R903.2.

4.1.1 Ondura®/Duracor® Corrugated Asphalt Roofing Sheet: Starting at the eave, the sheets are fastened at the corrugation crowns through the underlayment to the roof sheathing with the Ondura®/Duracor® nails described in Section 3.3. The fasteners must be of sufficient length to penetrate a minimum of 3/4 inch (19 mm) into the sheathing or through the sheathing, whichever is less. See Figure 1 for nailing pattern and Table 1 for wind uplift resistance and nailing pattern.

4.1.2 Ondura®/Duracor® Corrugated Asphalt Roofing Tile: Starting at the eave, the tiles are fastened through the underlayment to the roof sheathing with fasteners of sufficient length to penetrate a minimum of 3/4 inch (19 mm) into the sheathing or through the sheathing, whichever is less. See Figures 2 and 3 for nailing pattern

and Table 2 for wind uplift resistance and nailing pattern. Nails placed at tile crowns must be the Ondura®/Duracor® nails described in Section 3.3. Nails placed in the tile valleys at the underlaps, when required, must be corrosion-resistant, with a 0.125-inch (3.2 mm) shank diameter and a 0.410-inch (10.4 mm) head diameter.

4.1.3 Onduvilla®, and Onduvilla® FR Corrugated Asphalt Roofing Tile: Starting at the eave, the tiles are fastened through the underlayment to the roof sheathing with fasteners of sufficient length to penetrate a minimum of of 3/4 inch (19 mm) into the sheathing or through the sheathing, whichever is less. See Figure 4 for nailing pattern and Table 2 for wind uplift resistance and nailing pattern. Nails placed at tile crowns must be as described in Section 3.4. Nails placed in the tile valleys at the underlaps, when required, must be corrosion-resistant, with a 0.125-inch (3.2 mm) shank diameter and a 0.410-inch (10.4 mm) head diameter.

4.2 Roof Classification:

4.2.1 Ondura®/Duracor® Corrugated Asphalt Roofing Sheet and Tiles: When installed in accordance with this report, roof covering systems consisting of the Ondura®/Duracor® Corrugated Asphalt Roofing Sheet or Ondura®/Duracor® Corrugated Asphalt Roofing Tile, underlayment and solid or closely fitted plywood or OSB sheathing, have a Class C roof classification in accordance with IBC Sections 1505.1 and 1505.4 or IRC Section R902.1.. 4.2.2 Onduvilla® Corrugated Asphalt Roofing Tiles: When installed in accordance with this report, roof covering systems consisting of the Onduvilla® Corrugated Asphalt Tile, underlayment and solid or closely fitted plywood or OSB sheathing, have a Class C roof classification in accordance with IBC Sections 1505.1 and 1505.4 or IRC Section R902.1. 4.2.2 Onduvilla® FR Corrugated Asphalt Roofing Tiles: When installed in accordance with this report, roof covering systems consisting of the Onduvilla® FR Corrugated Asphalt Tile, two layers of mechanically secured GAF Versashield® Solo™ underlayment and solid or closely fitted plywood or OSB sheathing, have a Class A roof classification in accordance with IBC Sections 1505.1 and 1505.4 or IRC Section R902.1. 4.3 Wind Uplift Resistance:

See Tables 1 and 2 for allowable wind uplift resistance and corresponding nailing patterns. 4.4 Reroofing:

Reroofing must comply with the requirements in Section 4.4.1 (Replacement) or Section 4.4.2 (Recovering), as applicable. 4.4.1 Replacement: Prior to application of the sheets or tiles, the existing roof covering and underlayment must be completely removed. Any damaged sheathing must be replaced. The sheets or tiles, and underlayment, must be installed as described in Section 4.1 of this report.

4.4.2 Recovering: The sheets or tiles may be installed over existing asphalt shingle roofs, provided the requirements of IBC Section 1510 or IRC Section R907, as applicable, are met. When installed over an existing asphalt shingle roof with either a Class A or Class C roof

Page 39: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ESR-1957 | Most Widely Accepted and Trusted Page 3 of 4

classification, the composite assembly is considered a Class C roof covering.

5.0 CONDITIONS OF USE

The Ondura®/Duracor®, Onduvilla® and Onduvilla® FR

Corrugated Asphalt Sheet and Tile roofing products described in this report comply with, or are suitable alternatives to what is specified in those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with the applicable code, the

manufacturer’s published installation instructions and this report. The instructions within this report govern if there are conflicts between the manufacturer’s installation instructions and this report.

5.2 The roofing sheets and tiles are manufactured in under a quality control program with inspections by ICC-ES.

6.0 EVIDENCE SUBMITTED

6.1 Data in accordance with the ICC-ES Acceptance Criteria for Corrugated Asphalt Roofing Sheets and Tiles (AC330), dated April 2006 (editorially revised May 2011).

6.2 Report of fire classification testing in accordance with ASTM E 108.

7.0 IDENTIFICATION

The Ondura®/Duracor®, Onduvilla®, Onduvilla® FR Corrugated Asphalt Roofing Sheets and Tiles described in this report are identified by a label on each sheet or tile bearing the manufacturer’s name (OFIC North America Inc.), the product name, the manufacturing location, the roof fire classification (Class A, Class C), the name of the inspection agency (ICC-ES) and the evaluation report number (ESR-1957).

TABLE 1—MAXIMUM ALLOWABLE WIND DESIGN PRESSURES FOR ONDURA®/DURACOR® SHEETS

NAILING PATTERN1 PRODUCT SYSTEM

NUMBER SUBSTRATE Starter Row, End (Head) Laps

and End Row Field of Sheet

DESIGN WIND UPLIFT

PRESSURE (psf)

Ondura® / Duracor® 3

Min. 15/32-inch-thick exterior grade

plywood

One at each corrugation crown

One at each valley under lap,

41/2 inches from end of tile; one at

corrugation crowns marked X

as shown in Figure 2

47

Ondura® / Duracor® 4

Min. 15/32-inch-thick exterior grade

plywood

One at each corrugation crown

One at each corrugation crown

marked X as shown in Figure 3

54

For SI: 1 inch = 25.4 mm; 1 psf = 4.88 kg/m2. 1See Figure 1 for illustration.

Page 40: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ESR-1957 | Most Widely Accepted and Trusted Page 4 of 4

SYSTEM 1 SYSTEM 2

FIGURE 1―TYPICAL NAILING PATTERN FOR ONDURA®/DURACOR® SHEETS (SEE TABLE 1)

For SI: 1 inch = 25.4 mm.

Page 41: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ESR-1957 | Most Widely Accepted and Trusted Page 5 of 4

TABLE 2—MAXIMUM ALLOWABLE WIND DESIGN PRESSURE FOR ONDURA®/DURACOR®, ONDUVILLA® AND ONDUVILLA® FR

TILES

NAILING PATTERN1 PRODUCT SYSTEM

NUMBER SUBSTRATE Starter Row, End (Head) Laps

and End Row Field of Sheet

DESIGN WIND UPLIFT

PRESSURE (psf)

Ondura® / Duracor® 3

Min. 15/32-inch-thick exterior grade

plywood

One at each corrugation crown

One at each valley under lap,

41/2 inches from end of tile; one at

corrugation crowns marked X

as shown in Figure 2

47

Ondura® / Duracor® 4

Min. 15/32-inch-thick exterior grade

plywood

One at each corrugation crown

One at each corrugation crown

marked X as shown in Figure 3

54

Onduvilla® and Onduvilla® FR 5

Min. 15/32-inch-thick oriented strand

board or exterior grade plywood

One at each corrugation crown

1 ¾ inches from end of tile; one at

corrugation crowns marked X

as shown in Figure 4

70

For SI: 1 inch = 25.4 mm; 1 psf = 4.88 kg/m2. 1See Figure 2 for System No. 3 and Figure 3 for System No. 4.

For SI: 1 inch = 25.4 mm.

FIGURE 2―TYPICAL NAILING PATTERN FOR ONDURA®/DURACOR® TILES (SEE SYSTEM NO. 3, TABLE 2)

Page 42: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ESR-1957 | Most Widely Accepted and Trusted Page 6 of 4

For SI: 1 inch = 25.4 mm.

FIGURE 3―TYPICAL NAILING PATTERN FOR ONDURA®/DURACOR® TILES (SEE SYSTEM NO. 4, TABLE 2)

Page 43: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

8385 White Oak Avenue Rancho Cucamonga, CA 91730

909.483.0250 ph. | 909.483.0336 fx.

Page 1 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

CLIENT: OFIC North America Incorporated 4900 Ondura Drive Fredericksburg, Virginia 22407

Test Report No: RJ3539-1 Date: June 1, 2015 SUBJECT: Performance Testing on Corrugated Asphalt Roofing Tiles. SAMPLE ID: 1) Onduvilla Anthracite Black Tiles 2) Onduvilla Slate Grey Tiles 3) Onduvilla Florentino 3D Tiles Photographs of each of the three types of colored roof tiles are provided in the

appendix of this report. SAMPLING DETAIL: The samples were randomly selected by a QAI representative at the client’s

manufacturing facility located at Poligono Industrial El Campillo II, P12, APTDO 25, 48500 Gallarta, Spain on November 21, 2014. QAI documented the materials and manufacturing procedures in accordance with ICC-ES AC85, Section 3.1.

DATE OF RECEIPT: Samples were received at QAI Laboratories on December 1, 2014, 2015. TESTING PERIOD: May 18 thru 29, 2015. AUTHORIZATION: QAI Test Proposal FB-2014-091001-R1 dated September 22, 2014, signed by Paul

Nelson of OFIC North America Incorporated on September 23, 2014. TEST REQUESTED: Performance testing in accordance with ICC ES Acceptance Criteria for Corrugated

Asphalt Roofing Sheets and Tiles, AC330, Approved April 2006. Detailed test methods and procedures are provided on subsequent pages of this report.

TEST RESULTS: Detailed test results are provided on subsequent pages of this report. Prepared By Signed for and on behalf of

QAI Laboratories Inc.

Larry Burmer Matt Lansdowne Project Leader-Physical Testing Business Manager

Page 44: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 2 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

TABLE OF CONTENTS

Wind Resistance Test…………………………………………………………………………………….…Pages 3-4 Transverse Load Resistance Test...………………………………………………………………………Pages 5-11 Concentrated Load Resistance Test..…………………………………………………………………..Pages 12-15 Accelerated Weathering Test…………………………………………………………………………………Page 15 Wind Driven Rain Resistance Test.……………………………………………………………….……Pages 16-17 Fire Classification Test…………………..……………………………………………………………….……Page 17 Appendix..………..…………………..……………………………………………………………….……Pages 18-23

Page 45: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 3 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

WIND RESISTANCE TEST PER SECTION 3.1 OF ICC ES AC 330 Test Specimen Construction Detail One roof deck measuring approximately 10 feet high by 10 feet wide was constructed for the test. The roof deck consisted of 2 x 4 SPF wood rafters spaced 24 inches on center, 15/32 -inch thick Exposure 1 Oriented Strand Board (OSB), one layer of #30 roofing felt and Onduvilla Corrugated Asphalt Roofing Tiles. The 2 x 4 wood rafters were secured to 2 x 4 wooden end plates using four 16d common nails, two at each end of the rafter. The 15/32 -inch thick Exposure 1 OSB sheathing was secured to the rafters with 6d ring shank nails. The nails were spaced 6 inches on center around the perimeter of the roof deck and 12 inches on center in the field of deck. The Onduvilla Corrugated Asphalt Roofing Tiles were installed over the weather resistive barrier following the manufactures installation instructions. The Onduvilla Corrugated Asphalt Roofing Tiles were secured to the OSB sheathing with Onduvilla Fasteners measuring approximately 2¾” long by 0.125-inch in diameter with a 0.395-inch diameter Phillips Oval Head and 0.636-inch diameter plastic washer which allowed for a minimum ¾” penetration through the sheathing. The screws were located at each corrugation approximately 8” on center and 1¾” from the edge of the tile. In order to achieve a positive uniform load across the underside of the roof tiles, a 4 mil thick plastic sheet was placed between the roofing felt and OSB sheathing and sealed around the perimeter of the test deck. Holes were drilled in the OSB sheathing under each course and through each rafter to allow air to be applied uniformly to the plastic sheathing. The back of test assembly was sealed with ½-inch thick plywood to provide for an air tight test assembly. A photograph of the test assembly is provided in the appendix of this report.

Test Procedure Testing was conducted in accordance with UL 1897 Uplift Tests for Roof Covering Systems March 11, 2004. A positive (uplift) test pressure of 1-inch water column (5.2 psf) was applied to the underside of the roof panels for one minute and observations recorded. The test pressure was then increased in 1-inch water column (5.2 psf) increments until failure of roof assembly was observed. Test Requirements A) Fasteners shall maintain the securement of the fastened component. B) The roof panels shall show no evidence of progressive delamination or bubbling from within or between

any of the components of the assembly. C) The roof panels shall show no evidence of tearing, cracking, rupture or other evidence of opening of the

roofing system.

Page 46: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 4 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

WIND RESISTANCE TEST PER SECTION 3.1 OF ICC ES AC 330 (CONT.) Test Results At a test pressure of 14.4 inches of water column or 75 psf, the OSB sheathing, which was nailed to the wood framing, separated from the framing resulting in failure of the test assembly. The maximum pressure that the roof assembly withstood for 1 minute without failure was 13.5 inches of water column or 70 psf*. This would be considered the ultimate test load of the roof deck. A photograph of the mode of failure is provided in the appendix of this report. *Note: 70 psf would be equivalent to a basic wind speed of approximately 167 MPH. Observations The fasteners maintained the securement of the fastened component up to a test pressure of 13.5 inches of water column or 70 psf. The roof tiles showed no evidence of progressive delamination or bubbling from within or between any of the components of the assembly. The roof tiles showed no evidence of tearing, cracking, rupture or other evidence of opening of the roofing system. Conclusion The Onduvilla Corrugated Asphalt Roofing Tiles met the wind up-lift requirements of UL 1897 up to a test pressure of 70 psf.

Page 47: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 5 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

TRANSVERSE LOAD RESISTANCE TEST PER SECTION 3.2 OF ICC ES AC 330 Test Specimen Construction Detail Three test assemblies measuring 48” wide by 96” long overall were prepared for the test. Each assembly consisted of nominal 2 x 4 SPF wood rafters spaced 24 inches on center, 15/32 -inch thick Exposure 1 Oriented Strand Board (OSB), one layer of #30 roofing felt and Onduvilla Corrugated Asphalt Roofing Tiles. The studs were nailed to the top and bottom plates parallel to the panel’s length dimension using two 16d nails at each end of the stud. The Onduvilla Corrugated Asphalt Roofing Tiles were installed over the weather resistive barrier following the manufactures installation instructions. The Onduvilla Corrugated Asphalt Roofing Tiles were secured to the OSB sheathing with Onduvilla Fasteners measuring approximately 2¾” long by 0.125-inch in diameter with a 0.395-inch diameter Phillips Oval Head and 0.636-inch diameter plastic washer which allowed for a minimum ¾” penetration through the sheathing. The screws were located at each corrugation approximately 8” on center and 1¾” from the edge of the tile. Test Procedure Testing was conducted in accordance with Section 20 of ASTM E72-02, Standard Test methods of Conducting Strength Tests of Panels for Building Construction and Section 12 of ASTM E2322-03, Standard Test Method for Conducting Traverse and Concentrated Load Tests on Panels used in Floor and Roof Construction. The test specimens were individually placed horizontally, tile side up, on a vacuum chamber and supported at each end as shown in Figure 2 of ASTM E 2322. The exterior side of the tiles was covered with a 2 mil. thick plastic film thus facilitating a positive load on roof tiles. The plastic film was then sealed around the perimeter of the test chamber. The clear span of the test assembly was 93”. Dial indicators were placed midspan, at each edge of the panel. After initial deflection readings were recorded, test loads were applied to the specimen in 15 psf increments until an ultimate load was reached. At each increment, deflection measurements were recorded upon initial application of the load and after 5 minutes. After the measurements were recorded, the load was released and initial set readings recorded. Set readings were again recorded after a 5 minute period. Once the ultimate load was reached, the load was reduced to zero and the mode of failure recorded. The loads were uniformly applied to the specimen using a reversible controllable blower system. A photograph of the test set-up is provided in the appendix of this report.

Page 48: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 6 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

TRANSVERSE LOAD RESISTANCE TEST PER SECTION 3.2 OF ICC ES AC 330 (CONT.) Test Results

Applied Load (lbs)

Initial Net Deflection Under Load (in)

Specimen No.1

Specimen No.2

Specimen No.3

0 0.000 0.000 0.000 15 0.187 0.159 0.130 30 0.426 0.355 0.303 45 0.642 0.552 0.500 60 0.879 0.746 0.616 75 1.144 0.909 0.842 90 1.447 1.141 0.988

Applied Load (lbs)

Initial Net Set After Removal of Load (in)

Specimen No.1

Specimen No.2

Specimen No.3

0 0.000 0.000 0.000 15 0.035 0.027 0.025 30 0.072 0.052 0.057 45 0.089 0.070 0.077 60 0.113 0.093 0.091 75 0.143 0.117 0.115 90 0.176 0.146 0.139

Test results are shown graphically on pages 7 thru 10 of this report.

Applied Load (lbs)

Net Deflection After 5 Minutes Under Load (in)

Specimen No.1

Specimen No.2

Specimen No.3

0 0.000 0.000 0.000 15 0.195 0.166 0.132 30 0.432 0.361 0.314 45 0.651 0.560 0.508 60 0.896 0.765 0.631 75 1.163 0.928 0.874 90 1.461 1.157 1.010

Applied Load (lbs)

Net Set 5 Minutes After Removal of Load (in)

Specimen No.1

Specimen No.2

Specimen No.3

0 0.000 0.000 0.000 15 0.032 0.024 0.023 30 0.068 0.046 0.049 45 0.080 0.064 0.073 60 0.102 0.083 0.088 75 0.126 0.105 0.108 90 0.155 0.128 0.129

Page 49: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 7 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

TRANSVERSE LOAD RESISTANCE TEST PER SECTION 3.2 OF ICC ES AC 330 (CONT.) Test Results (Cont.)

Initial Net Deflection Under Load

Page 50: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 8 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

TRANSVERSE LOAD RESISTANCE TEST PER SECTION 3.2 OF ICC ES AC 330 (CONT.) Test Results (Cont.)

Net Deflection After 5 Minutes Under Load

Page 51: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 9 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

TRANSVERSE LOAD RESISTANCE TEST PER SECTION 3.2 OF ICC ES AC 330 (CONT.) Test Results (Cont.)

Initial Net Set After Removal of Load

Page 52: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 10 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

TRANSVERSE LOAD RESISTANCE TEST PER SECTION 3.2 OF ICC ES AC 330 (CONT.) Test Results (Cont.)

Net Set 5 Minutes After Removal of Load

Net Set After 5 Minutes

Page 53: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 11 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

TRANSVERSE LOAD RESISTANCE TEST PER SECTION 3.2 OF ICC ES AC 330 (CONT.) Test Results (Cont.) Observations Specimen No.1 At an ultimate test load of 118 psf, the wood framing cracked. The maximum load maintained for the full 5 minute duration was 105 psf. Specimen No.2 At an ultimate test load of 127 psf, the wood framing cracked. The maximum load maintained for the full 5 minute duration was 120 psf. Specimen No.3 At an ultimate test load of 130 psf, the wood framing cracked. The maximum load maintained for the full 5 minute duration was 120 psf. The average maximum load sustained for 5 minutes for the three specimens was 115 psf. A photograph showing the mode of failure is provided in the appendix of this report.

Page 54: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 12 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

CONCENTRATED LOAD RESISTANCE TEST PER SECTION 3.3 OF ICC ES AC 330 Test Procedure Testing was conducted in accordance with Section 21 of ASTM E72-02, Standard Test methods of Conducting Strength Tests of Panels for Building Construction and Section 13 of ASTM E2322-03, Standard Test Method for Conducting Traverse and Concentrated Load Tests on Panels used in Floor and Roof Construction on the three transverse load specimens after the completion of the transverse load test. The test specimens were individually placed on a level surface and a 44.5 N (10 lb.) incremental load applied to the weakest (corrugation) area and a 445 N (100 lb) incremental load applied to the strongest (valley) area on the surface of the roof tile. The load was applied through a 25.4 mm (1”) diameter steel bar having a 1.3 mm (0.05”) radius loading edge. Deflection readings were recorded at each increment to failure or until a maximum load of 4.45 kN (1,000 lbs.) was reached. After reaching the maximum load, the load was removed and the depth of the indentation determined to the nearest 0.025 mm (0.001”). Test Results Applied

Load (lbs)

Deflection at Strongest Area (in) Specimen

No.1 Specimen

No.2 Specimen

No.3 0 0.000 0.000 0.000

100 0.126 0.119 0.122 200 0.201 0.198 0.200 300 0.273 0.254 0.266 400 0.342 0.323 0.328 500 0.411 0.398 0.405 600 0.499 0.485 0.488 700 0.803 0.795 0.799

Test results are shown graphically on pages 13 and 14 of this report.

Applied Load (lbs)

Deflection at Weakest Area (in) Specimen

No.1 Specimen

No.2 Specimen

No.3 0 0.000 0.000 0.000

10 0.039 0.035 0.036 20 0.046 0.044 0.045 30 0.113 0.112 0.113 40 0.262 0.260 0.259 50 0.463 0.460 0.458 60 0.696 0.688 0.690 70 0.850 0.844 0.865

Page 55: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 13 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

CONCENTRATED LOAD RESISTANCE TEST PER SECTION 3.3 OF ICC ES AC 330 (CONT.) Test Results (Cont.)

Specimen Deflection at Strongest Area

Page 56: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 14 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

CONCENTRATED LOAD RESISTANCE TEST PER SECTION 3.3 OF ICC ES AC 330 (CONT.) Test Results (Cont.)

Specimen Deflection at Weakest Area

Page 57: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 15 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

CONCENTRATED LOAD RESISTANCE TEST PER SECTION 3.3 OF ICC ES AC 330 (CONT.) Test Results

Specimen No.

Maximum load (lbs) Residual Indentation (in) Mode of Failure

Strongest Area

Weakest Area

Strongest Area

Weakest Area

Strongest Area

Weakest Area

1 723 100 0.205 0.490 Roof tile tore at steel bar

Roof tile tore at steel bar

2 745 96 0.211 0.495 Roof tile tore at steel bar

Roof tile tore at steel bar

3 730 98 0.208 0.483 Roof tile tore at steel bar

Roof tile tore at steel bar

Average 733 98 0.208 0.489 * * * * * * Photographs showing the results of the concentrated load test are provided in the appendix of this report. ACCELERATED WEATHERING TEST PER SECTION 3.4 OF ICC ES AC 330 Test Procedure Five 3” x 12” specimens were cut from each of the three sampled products and placed in a Q-Panel QUV machine and subjected to 2,000 hours of accelerated aging using Cycle 5 and UVB-313 lamps as described in ASTM G 154. The black panel temperature was maintained at 80ºC during the light portion of the test and 50°C during the condensation portion of test. The average irradiance level was 0.62w/m2 @ 310nm during the light portion of the test. Test Requirements No visible surface or structural changes, such as peeling, chipping, cracking flaking or pitting, shall be observed under minimum five-power magnification. Test Results No visible surface or structural changes, such as peeling, chipping, cracking flaking or pitting, was observed under minimum five-power magnification on any of the 15 specimens.

Page 58: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 16 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

WIND-DRIVEN RAIN RESISTANCE TEST PER SECTION 3.5 OF ICC ES AC 330 Test Specimen Construction Detail One roof deck measuring approximately 10 feet high by 10 feet wide was constructed for the test. The roof deck consisted of 2 x 4 SPF wood rafters spaced 24 inches on center, 15/32 -inch thick Exposure 1 Oriented Strand Board (OSB), one layer of #30 roofing felt and Onduvilla Corrugated Asphalt Roofing Tiles. The 2 x 4 wood rafters were secured to 2 x 4 wooden end plates using four 16d common nails, two at each end of the rafter. The 15/32 -inch thick Exposure 1 OSB sheathing was secured to the rafters with 6d ring shank nails. The nails were spaced 6 inches on center around the perimeter of the roof deck and 12 inches on center in the field of deck. The Onduvilla Corrugated Asphalt Roofing Tiles were installed over the weather resistive barrier following the manufactures installation instructions. The Onduvilla Corrugated Asphalt Roofing Tiles were secured to the OSB sheathing with Onduvilla Fasteners measuring approximately 2¾” long by 0.125-inch in diameter with a 0.395-inch diameter Phillips Oval Head and 0.636-inch diameter plastic washer which allowed for a minimum ¾” penetration through the sheathing. The screws were located at each corrugation approximately 8” on center and 1¾” from the edge of the tile. Test Procedure Testing was performed in accordance with Section 3.3 of ICC ES Evaluation Guideline for Asphalt Shingles Made with an Attached Interply, EG 270, Approved August 2004. The roof deck was adjusted to a 2:12 slope and the underside of the test specimen photographed. An air flow velocity between 35 and 40 miles per hour (56 and 64 km/h) along with a simulated rainfall rate of 6 inches per hour was applied across the surface of the test specimen. The test specimen was subjected to three 15 minute wind-driven rain cycles with a 5 minute off period after each cycle during which time the joints on the underside of the specimen was examined for water infiltration. Upon completion of the test, roofing components were dismantled and the condition of the lapped areas and the underside of the test specimen noted and photographed. Prior to testing, the air velocity and simulated rainfall was measured at random locations (see table below) to ensure that the wind-driven rain was distributed uniformly across the surface of the test specimen.

Measurement Locations

Measured Air Velocity1

(mph)

Measured Rainfall2

(in) Left lower edge 35 5½

Center lower edge 38 6 Right lower edge 35 5½ Middle left edge 38 6¼ Middle Center 40 6¼

Middle right edge 38 6¼ Left upper edge 38 6

Center upper edge 40 6¼ Right upper edge 40 6 Percent Variation 12.5 12.0

Page 59: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 17 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

WIND-DRIVEN RAIN RESISTANCE TEST PER SECTION 3.5 OF ICC ES AC 330 Test Procedure (Cont.) Note 1: The air flow velocity was measured at the locations noted in the table using a calibrated vane-type

velocimeter over a 24 square inch area. The air flow was delivered to the test specimen using dual gas powered wind machines and baffle system.

Note 2: The simulated rainfall was measured at the locations noted in the table using a sealed container

covering a 24 square inch area. The water was delivered to the test specimen using a water spray system connected in line with a calibrated flow meter.

A photograph of the test set-up is provided in the appendix of this report. Test Requirements There shall be no leaks. The extent of shingle or panel fluttering during the test periods shall be noted and whether the fluttering was due to oversized nail holes or loosening fasteners. Test Results

Cycle No. Observations

1 No leaks were observed on the underside of the test specimen. No fluttering of the roof tiles was observed.

2 No leaks were observed on the underside of the test specimen. No fluttering of the roof tiles was observed.

3 No leaks were observed on the underside of the test specimen. No fluttering of the roof tiles was observed.

Upon dismantling of the roof components, lapped areas were intact with no damage noted. A photograph of the underside of the test specimen after the conclusion of the test is provided in the appendix of this report. FIRE CLASSIFICATION TEST PER SECTION 3.6 OF ICC ES AC330 Results of fire testing are provided in QAI Test Report Number RJ3539-2 and RJ3539-3 dated June 18, 2015.

Page 60: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 18 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

APPENDIX

Photograph No.1

Anthracite Black Roof Tile

Photograph No.2

Slate Gray Roof Tile

Photograph No.3

Florentino Roof Tile

Page 61: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 19 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

APPENDIX

Photograph No.4

Wind Up-lift Test Assembly

Photograph No.5

Failure of Wind Up-lift Test Assembly The OSB sheathing, which was nailed to the wood framing, separated from the framing

Page 62: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 20 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

APPENDIX

Photograph No.6

Transverse Load Test Set-up

Photograph No.7

Typical Results of Transverse Load Test The wood framing cracked

Page 63: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 21 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

APPENDIX

Photograph No.8

Typical Results of Concentrated Load Test on Strongest Area Roof tile tore at steel bar

Photograph No.9

Typical Results of Concentrated Load Test on Weakest Area Roof tile tore at steel bar

Page 64: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 22 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

APPENDIX

Photograph No.10

Wind Driven Rain Test Set-up

Page 65: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Client: OFIC North America Incorporated Report No: RJ3539-1

Date: June 1, 2015 Page 23 of 23

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

APPENDIX

Photograph No.11

Underside of Wind Driven Rain Test Specimen before the Test

Photograph No.12

Underside of Wind Driven Rain Test Specimen after the Test

****End of Report****

Page 66: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

8385 White Oak AvenueRancho Cucamonga, CA 91730909.483.0250 ph. | 909.483.0336 fx.

Page 1 of 6 THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG [email protected]

CLIENT: OFIC NORTH AMERICA INCORPORATED 4900 Ondura Drive Fredericksburg, Virginia 22407

Test Report No: RJ3539-2 Date: June 18, 2015

SUBJECT: Fire Classification Testing on Corrugated Asphalt Roofing Tiles.

SAMPLE ID: Onduvilla FR Red. A photograph of the roof tile is provided in the appendix of this report.

SAMPLING DETAIL: The samples were randomly selected by a QAI representative at the client’s manufacturing facility located at P.K. 2 Sapanca, 54600, Sakarya, Turkey on March 12, 2014. The sampled products were forwarded to the client’s facility at 4900 Ondura Drive, Fredericksburg, Virginia for application where a red acrylic paint was applied to the tiles exterior surface. The application of the red paint was witnessed by a QAI representative on March 27, 2015. QAI documented the materials and manufacturing procedures in accordance with ICC-ES AC85, Section 3.1.

DATE OF RECEIPT: Samples were received on April 8, 2015.

TESTING PERIOD: May 19, 2015.

AUTHORIZATION: Testing authorized by Paul Nelson under QAI Test Proposal # FB-2014-091001-R1 dated September 22, 2014.

TEST REQUESTED: Conduct a series of Class A Intermittent Flame, Spread of Flame, and Burning Brand roof fire tests on the sampled material in accordance with the methods and procedures outlined in ASTM Test Method E108-11, "Standard Test Methods for Fire Tests of Roof Coverings"(E108).

TEST RESULTS: Detailed test results are provided on subsequent pages of this report.

CONCLUSION: The Sampled Onduvilla FR Corrugated Asphalt Roofing met the requirements of ASTM E108-11 for Class A Burning Brand, Intermittent Flame and Spread of Flame.

Prepared By Signed for and on behalf of QAI Laboratories

David Royer Brian Ortega Laboratory Technician Fire Analyst Fire Technology Dept. Fire Technology Dept.

Page 67: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

CLIENT: OFIC NORTH AMERICA INCORPORATED Report No.: RJ3539-2

June 18, 2015 Page 2 of 6

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG

[email protected]

FIRE CLASSIFICATION TEST PER ASTM E 108-11 Storage of Assembled Test Decks All test deck assemblies were stored indoors at temperatures not lower than 60ºF (16ºC) nor higher than 90ºF (32ºC) for the period of time necessary to cure the assembly components prior to testing. The test decks were stored in such a manner to assure that each deck was surrounded by free circulating air. Roof System and Test Deck Assembly Construction Details

The test decks were constructed by QAI personnel following the construction details outlined in ASTM E108-11 specification standard for deck construction.

Lumber: Nominal 2” x 4” Douglas Fir, having a moisture content between 8 and 12%. Deck: 15/32” AC Exterior grade plywood, having a moisture content not greater than 8%. Caulking: 3M Fire Barrier Sealant CP 25WB+ intumescent Red caulking was used to seal all

seams and joints on the plywood test decks. Underlayment: Two layers of Versashield ® Solo™ Fire Resistant slip sheet made by GAF Materials

Corporation. The roof underlayment was fastened to the substrate using T50 flat head staples at 18” intervals and incorporated a 2” overlap.

Roof Covering: Onduvilla FR Corrugated Fire Retardant Asphalt roofing shingles fastened to the deck

with Onduvilla Fasteners measuring approximately 2¾” long by 0.125-inch in diameter with a 0.395-inch diameter Phillips Oval Head and 0.636-inch diameter plastic washer allowing a minimum ¾” penetration through the sheathing. The fasteners were placed at the apex of each corrugation and centered between the two overlapping guides. Each course was overlapped to leave 12” exposure and fastened at 14” above the leading edge of the shingle.

Page 68: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

CLIENT: OFIC NORTH AMERICA INCORPORATED Report No.: RJ3539-2

June 18, 2015 Page 3 of 6

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG

[email protected]

FIRE CLASSIFICATION TEST PER ASTM E 108-11 (CONT.)

Burning Brand Test – Class A (Four Test Decks) Test Parameters Wind Velocity: 1056 ft/min ± 44 ft/min Test Deck Slope: 5" per Horizontal Foot Class A Brands: Size: 12" x 12" x 2" (one per test deck) The brands were placed on the deck following the flame application schedule as outlined in Section 10.4.2. of ASTM E 108-11. Brands were placed at the location considered most vulnerable which was determined to be centered over the horizontal joint.

Test Results

Burning Brand Details

Test Deck Assembly

Ignition (MM:SS)

Brand Extinguished (MM:SS)

Test Terminated (MM:SS)

Pass/Fail

1 00:27 24:56 50:30 Pass

2 00:26 23:00 65:00 Pass

3 00:29 23:00 54:00 Pass

4 00:28 25:35 63:00 Pass

Observations All four test decks performed in a similar manner. At no time during the test was there any evidence of flaming on the underside of the test decks, neither did any glowing embers fall from the deck assembly.

Page 69: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

CLIENT: OFIC NORTH AMERICA INCORPORATED Report No.: RJ3539-2

June 18, 2015 Page 4 of 6

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG

[email protected]

FIRE CLASSIFICATION TEST PER ASTM E 108-11 (CONT.) Intermittent Flame Test – Class A (Two Test Decks)

Test Parameters Wind Velocity: 1056 ft/min ± 44 ft/min Flame Temperature: 1400 ± 50º F Test Deck Slope: 5" per Horizontal Foot Cycling Periods: 15 cycles: 2-minute Flame-On, 2-minute Flame-Off

Test Results Test Deck Assembly #1: The deck assembly ignited at 1 minute and 18 seconds then self-extinguished 3 seconds during the following flame-off cycle. The test was terminated at 60 minutes with no evidence of flaming on the underside of the deck, neither was there any glowing embers or displacement of any portion of the deck.

Test Deck Assembly #2: The deck assembly ignited at 52 seconds then self-extinguished during the following flame-off cycle. On the 2nd flame on cycle the slight surface ignition occurred at 5 minutes and 20 seconds then self extinguished on the off cycle. The test was terminated at 60 minutes with no evidence of flaming on the underside of the desk, neither was any glowing embers or displacement of any portion of the desk.

Page 70: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

CLIENT: OFIC NORTH AMERICA INCORPORATED Report No.: RJ3539-2

June 18, 2015 Page 5 of 6

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG

[email protected]

FIRE CLASSIFICATION TEST PER ASTM E 108-11 (CONT.) Spread of Flame Test – Class A (Two Test Deck)

Test Parameters

Wind Velocity: 1056 ft/min ± 44 ft/min Flame Temperature: 1400 ± 50º F Test Deck Slope: 5” per Horizontal Foot Flame Application: 10 Minutes Test Results

Spread of Flame Details

Test Deck Assembly

Ignition Time (MM/SS)

Maximum Spread of

Flame (ft)

Lateral Spread

of Flame (ft)

Flame Front Recession (MM/SS)

Pass/Fail

1 01:17 3.5 None 06:10 Pass

2 01:10 3.0 None 06:00 Pass

Observations Both decks performed in a similar manner. After the ignition of the test sample surface the flame front progressed steadily to the maximum spread distance and then receded back to the test flame impingement area. CONDITIONS OF ACCEPTANCE FOR CLASSIFICATION BY ASTM E108 At no time during or after the intermittent flame, spread of flame or burning brand tests shall: 1. Any portion of the roof covering material be blown or fall off the test deck in the form of flaming or glowing

brands that continue to glow after reaching the floor, or 2. The roof deck be exposed, or 3. Portions of the roof deck fall away in the form of particles that continue to glow after reaching the floor. 4. At no time during the Class A intermittent flame or burning brand tests shall there be sustained flaming of

the underside of the deck. 5. At the conclusion of the spread of flame tests, the flaming shall not have spread beyond 6 feet for Class A,

and there shall have been no significant lateral spread of flame from the path directly exposed to the test flame.

Page 71: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

CLIENT: OFIC NORTH AMERICA INCORPORATED Report No.: RJ3539-2

June 18, 2015 Page 6 of 6

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG

[email protected]

APPENDIX

Photograph No.1

Onduvilla FR Red Corrugated Asphalt Roof Tile

********** End of Report

Page 72: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

8385 White Oak Avenue

Rancho Cucamonga, CA 91730

909.483.0250 ph. | 909.483.0336 fx.

Page 1 of 6

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG

[email protected]

CLIENT: OFIC NORTH AMERICA INCORPORATED

4900 Ondura Drive Fredericksburg, Virginia 22407

Test Report No: RJ3539-3 Date: June 18, 2015

SUBJECT: Fire Classification Testing on Corrugated Asphalt Roofing Tiles. SAMPLE ID: 1) Onduvilla Anthracite Black Tiles 2) Onduvilla Slate Grey Tiles 3) Onduvilla Florentino 3D Tiles SAMPLING DETAIL: The samples were randomly selected by a QAI representative at the client’s

manufacturing facility located at Poligono Industrial El Campillo II, P12, APTDO 25, 48500 Gallarta, Spain on November 21, 2014. QAI documented the materials and manufacturing procedures in accordance with ICC-ES AC85, Section 3.1.

DATE OF RECEIPT: Samples were received at QAI Laboratories on December 1, 2014. TESTING PERIOD: May 31- June 3, 2015. AUTHORIZATION: Testing authorized by Paul Nelson under QAI Test Proposal # FB-2014-091001-R1

dated September 22, 2014. TEST REQUESTED: Conduct a series of Class C Intermittent Flame, Spread of Flame, and Burning Brand

roof fire tests on the sampled material in accordance with the methods and procedures outlined in ASTM Test Method E108-11, "Standard Test Methods for Fire Tests of Roof Coverings"(E108).

TEST RESULTS: Detailed test results are provided on subsequent pages of this report. CONCLUSION: The Sampled Onduvilla Corrugated Asphalt Roofing Tiles met the requirements of

ASTM E108-11 for Class C Burning Brand, Intermittent Flame and Spread of Flame. Prepared By Signed for and on behalf of QAI Laboratories

David Royer Brian Ortega Laboratory Technician Fire Analyst Fire Technology Dept. Fire Technology Dept.

Page 73: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

CLIENT: OFIC NORTH AMERICA INCORPORATED Report No.: RJ3539-3

June 18, 2015 Page 2 of 6

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG

[email protected]

FIRE CLASSIFICATION TEST PER ASTM E 108-11 Storage of Assembled Test Decks All test deck assemblies were stored indoors at temperatures not lower than 60ºF (16ºC) nor higher than 90ºF (32ºC) for the period of time necessary to cure the assembly components prior to testing. The test decks were stored in such a manner to assure that each deck was surrounded by free circulating air. Roof System and Test Deck Assembly Construction Details

The test decks were constructed by QAI personnel following the construction details outlined in ASTM E108-11 specification standard for deck construction.

Lumber: Nominal 2” x 4” Douglas Fir, having a moisture content between 8 and 12%. Deck: 15/32” AC Exterior grade plywood, having a moisture content not greater than 8%. Underlayment: One layer of ASTM D226 30# felt asphalt roof underlayment was fastened to the

substrate using T50 flat head staples at 18” intervals and incorporated a 2” overlap. Roof Covering: Onduvilla Corrugated Fire Retardant Asphalt roofing shingles fastened to the deck with

Onduvilla Fasteners measuring approximately 2¾” long by 0.125-inch in diameter with a 0.395-inch diameter Phillips Oval Head and 0.636-inch diameter plastic washer allowing a minimum ¾” penetration through the sheathing. The fasteners were placed at the apex of each corrugation and centered between the two overlapping guides. Each course was overlapped to leave 12” exposure and fastened at 14” above the leading edge of the shingle.

Page 74: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

CLIENT: OFIC NORTH AMERICA INCORPORATED Report No.: RJ3539-3

June 18, 2015 Page 3 of 6

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG

[email protected]

FIRE CLASSIFICATION TEST PER ASTM E 108-11 (CONT.)

Burning Brand Test – Class C (Two Test Decks) Test Parameters Wind Velocity: 1056 ft/min ± 44 ft/min Test Deck Slope: 5" per Horizontal Foot Class C Brands: Size: 1½" x 1½" x 25/32" (20 per test deck) The brands were placed on the deck following the flame application schedule as outlined in Section 10.4.3 of ASTM E 108-11. Brands were placed at the locations considered most vulnerable which was determined to be in the valleys of the corrugations centered over panel joints in the test deck

Test Results

Burning Brand Details

Test Deck Assembly

Ignition (MM:SS)

Last Brand Extinguished

(MM:SS)

Test Terminated (MM:SS)

Pass/Fail

1 03:15 28:10 29:30 Pass

2 06:26 24:42 26:50 Pass

Observations Both test decks performed in a similar manner. At no time during the test was there any evidence of flaming on the underside of the test decks, neither did any glowing embers fall from the deck assembly.

Page 75: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

CLIENT: OFIC NORTH AMERICA INCORPORATED Report No.: RJ3539-3

June 18, 2015 Page 4 of 6

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG

[email protected]

FIRE CLASSIFICATION TEST PER ASTM E 108-11 (CONT.) Intermittent Flame Test – Class C (Two Test Decks)

Test Parameters Wind Velocity: 1056 ft/min ± 44 ft/min Flame Temperature: 1300 ± 50º F Test Deck Slope: 5" per Horizontal Foot Cycling Periods: 3 cycles: 1-minute Flame-On, 2-minute Flame-Off

Test Results Test Deck Assembly #1: The deck assembly ignited at 56 seconds then self-extinguished during the following flame-off cycle. The test deck continued to ignite and self-extinguish during the following cycles. The test was terminated at 8 minutes with no evidence of flaming on the underside of the deck, neither was there any glowing embers or displacement of any portion of the deck.

Test Deck Assembly #2: The deck assembly ignited at 3 minutes 36 seconds then self-extinguished during the following flame-off cycle. The test deck continued to ignite and self-extinguish during the following cycles. The test was terminated at 8 minutes 30 seconds with no evidence of flaming on the underside of the desk, neither was any glowing embers or displacement of any portion of the desk.

Page 76: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

CLIENT: OFIC NORTH AMERICA INCORPORATED Report No.: RJ3539-3

June 18, 2015 Page 5 of 6

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG

[email protected]

FIRE CLASSIFICATION TEST PER ASTM E 108-11 (CONT.) Spread of Flame Test – Class C (Two Test Deck)

Test Parameters

Wind Velocity: 1056 ft/min ± 44 ft/min Flame Temperature: 1300 ± 50º F Test Deck Slope: 5” per Horizontal Foot Flame Application: 4 Minutes Test Results

Spread of Flame Details

Test Deck Assembly

Ignition Time (MM/SS)

Maximum Spread of

Flame (ft)

Lateral Spread

of Flame (ft)

Flame Front Recession (MM/SS)

Pass/Fail

1 01:07 3.5 None 04:00 Pass

2 01:08 12.5 None 04:00 Pass

Observations Both decks performed in a similar manner. After the ignition of the test sample surface the flame front progressed steadily to the maximum spread distance until the test was terminated at 4 minutes. CONDITIONS OF ACCEPTANCE FOR CLASSIFICATION BY ASTM E108 At no time during or after the intermittent flame, spread of flame or burning brand tests shall: 1. Any portion of the roof covering material be blown or fall off the test deck in the form of flaming or glowing

brands that continue to glow after reaching the floor, or 2. The roof deck be exposed, or 3. Portions of the roof deck fall away in the form of particles that continue to glow after reaching the floor. 4. At no time during the Class C intermittent flame or burning brand tests shall there be sustained flaming of

the underside of the deck. 5. At the conclusion of the spread of flame tests, the flaming shall not have spread beyond 13 feet for Class

C, and there shall have been no significant lateral spread of flame from the path directly exposed to the test flame.

Page 77: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

CLIENT: OFIC NORTH AMERICA INCORPORATED Report No.: RJ3539-3

June 18, 2015 Page 6 of 6

THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.

THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.

WWW.QAI.ORG

[email protected]

APPENDIX

Photograph No.1

Anthracite Black Roof Tile

Photograph No.2

Slate Gray Roof Tile

Photograph No.3

Florentino Roof Tile

******End of Report******

Page 78: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Seite 6/6

Peter Flüeler, dipl. Ing. ETH/ Sia usic

Überlandstr. 129, 8600 Dübendorf Tel. 044 932 1983 /Fax 044 972 1723

[email protected] [email protected] www.fluelerpolymer.ch Spin-off EMPA

OFITECH SASU

Monsieur Laurent Lainé

Zone Industrielle B.P. 17

F-76480 Yainville France

Test report No. 346-14/1.2e

Order:

Exploratory determination of hail impact resistance following the

protocol no. 1 ed. 1.03 and no. 12 ed. 1.03, 1.06.2014 “Association

of Public Building Insurance Companies APBIC” Bern Switzerland

Application: roof tiles and bitumen plates (impact angle 90°):

Customer: OFITECH SASU, Zone Industrielle B.P. 17, F-76480 Yainville, France

Test objects: Corrugated bituminous tile, type ONDUVILLA PPHR, cover width 1.0

m, cover length 0.32 m, weight 4 kg/m2, colour brown flamed,

tested as an assembly of 3 rows of 5 tiles, mounted on tiling

battens of 7x5 cm and plywood plate, support distance 32 cm

Reference: L. Lainé

Date of order: September 15, 2014, order quality 14-065

Delivery of test samples: October 15, 2014

Test date: October 22, 2014

Number of pages: 4 including annex

Results:

Remarks:

Achieved *HIR-class: undamaged by 2 cm ice balls

Water tightness: HIR 2

Appearance: HIR 2

Mounting according to customer instructions

*HIR: Hail Impact Resistance provisional classification

Dübendorf / Aathal, October 27, 2014

Flüeler Polymer Consulting GmbH

P. Flüeler

Page 79: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Customer: OFITECH SASU, Zone Industrielle B.P. 17, F-76480 Yainville

Order: Determination of hail impact resistance following APBIC-protocol, test report No. 346-14/1.2e page 2/4

1. Summary

Impact tests using ice balls of Ø 2 cm at a velocity of 21 m/s caused a maximum kinetic energy of

0.8 Joule:

Property Ice ball diameter (mm) Dim.

20

Number of impacts 10 -

HIR-class level (minimum) 0.7 Joule

Achieved kin. energy 0.75±0.04 Joule

Assessments of functions: -

Water tightness n.d.

Appearance n.d.

n.d. no damage details see table of test data on page 4

2. Material description

The test samples and tiling battens were delivered on October 15, 2014 by French postal services

and then stored in the test laboratory. The description of test object is as follows:

Aspect Description

Objects: Roofing sheets

Designation: ONDUVILLA PPHR

Origin: Onduline, F-76480 Yainville France

Material base: Wooden fibers in bitumen, pressed

Size:

Wave height:

Covering surface:

Covering size:

Width minimal:

1070 x 400 mm

40 mm

0.32 m2

1.0 m

~ 3 mm

Weight: 4 kg/m2

Cross section: See data sheet

Appearance top: Matt, pressed fine texture

Appearance bottom: Raw

Markings: None

Colour: Brown, flamed

Status: New

Size of test sample:

Test field:

Construction:

3 sheets, 6 waves

Middle sheet

Tiling batten 70x50 mm on plywood plate

Supporting plate: Plywood plate 26 mm, 9-times laminated

Fixation: Original screwing, 2 screws on overlapped wave tops

Test mounting: Test plate on tilting steel frame

Page 80: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Customer: OFITECH SASU, Zone Industrielle B.P. 17, F-76480 Yainville

Order: Determination of hail impact resistance following APBIC-protocol, test report No. 346-14/1.2e page 3/4

4. Photos

Photo 1: Zone with 2 cm-ice ball target, tiles remained undamaged

Page 81: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

Se

ite 4

/4

Pe

ter Flü

ele

r, dip

l. Ing

. ETH

/ Sia u

sic

Üb

erla

nd

str. 129

, 860

0 D

üb

en

do

rf Tel. 0

44 9

32 1

983 /Fa

x 044

823

44

96

p.flu

ele

r@h

ispe

ed

.ch in

fo@

flue

lerp

oly

me

r.ch

ww

w.flu

ele

rpo

lym

er.c

h Sp

in-o

ff EM

PA

Page 82: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA  by  ONDULINE  NORTH  AMERICA,  INC.  Corrugated  Shingle  and  Accessory  Lifetime  Limited  Warranty    

  Page  1  of  3  

 

Thank  you  for  choosing  the  ONDUVILLA  Roofing  System.    This  document  summarizes  the  terms  applicable  to  ONDUVILLA’s  Standard  Lifetime  Limited  Warranty  (the  “Warranty”).    DEFINITIONS    Corrugated  shingles  and  roofing  accessories  sold  under  the  product  name  ONDUVILLA  (the  “Product”)  are  warranted  by  Onduline  North  America,  Inc.  (“Onduline”)  to  the  Owner  (as  defined  below)  to  be  free  from  manufacturing  defects  in  workmanship  or  material  that  adversely  affects  the  performance  of  the  Product  or  results  in  leaks  impacting  the  building  or  substructure  to  which  the  Product  is  attached  (the  “Property”)  during  the  Warranty  Period  (as  defined  below).        “Owner”  shall  mean  the  person  or  entity  owning  the  Property  when  the  Product  is  installed  or  the  next  subsequent  purchaser  if  the  owner  at  the  time  of  installation  of  the  Product  merely  holds  the  Property  for  sale  and  the  property  changes  ownership  within  2  years  of  Product  installation  and  the  warranty  is  transferred  properly.    See  Transferability  section  below.    “Installer”  shall  mean  the  person  or  company  that  installed  the  Product  on  the  Property.    “Lifetime”  shall  mean  the  time  that  the  Owner  owns  the  single  family  detached  residence  on  which  the  Product  was  installed.    For  any  other  type  of  building  or  structure  that  is  not  a  single  family  detached  residence,  Lifetime  means  a  period  of  30  years  from  the  date  of  Product  installation  on  the  Property.    “Warranty  Period”  shall  begin  on  the  date  the  Product  was  purchased,  and  shall  end  when  the  Lifetime  ends.    TRANSFERABILITY    Other  than  the  transfer  to  the  purchaser  of  the  Property  within  2  years  of  Product  installation  on  the  Property,  no  Warranty  may  be  assigned  or  transferred  in  any  way,  directly  or  indirectly.  The  Owner  at  the  time  the  Product  is  installed  on  the  Property  must  provide  proof  of  purchase  of  the  Product  and  proof  of  the  installation  date  to  the  purchaser  of  the  Property  in  order  to  transfer  the  Warranty.    

PRODUCT  REPLACEMENT    Subject  to  the  conditions  set  forth  below,  in  the  event  that  the  Product  or  any  portion  thereof  is  found  to  be  defective  in  workmanship  or  materials,  upon  presentation  of  the  Warranty  Certificate  or  proof  of  purchase,  as  applicable,  Onduline  will  exchange  new  Product  for  defective  Product  in  accordance  with  the  terms  of  the  applicable  Warranty.    Any  such  replacement  Product  shall  be  warranted  only  for  the  balance  of  any  period  applicable  to  the  Product  originally  purchased.        COLOR  CHANGE  Fading,  discoloration  or  any  variations  in  color  caused  by  Product  exposure  to  sunlight  does  not  constitute  a  failure  of  the  Product  or  a  warranty  claim,  as  it  does  not  affect  the  performance  of  the  Product.    WIND  SPEED  WARRANTY  Included  in  the  Standard  Lifetime  Limited  Warranty  is  a  Wind  Speed  Warranty  that  is  effective  immediately  upon  installation  of  Product  on  Property  when  Product  is  installed  according  to  Onduline’s  published  installation  instructions  for  Product.  When  Product  is  installed  with  ONDUVILLA  brand  nails  (minimum  3-­‐inch  length),  the  Product  is  warranted  to  withstand  110  miles-­‐per-­‐hour  winds  with  no  material  damage  to  Product.  When  Product  is  installed  with  ONDUVILLA  brand  screws  (minimum  2.7-­‐inch  length),  the  Product  is  warranted  to  withstand  150  miles-­‐per-­‐hour  winds  with  no  material  damage  to  Product.  The  Wind  Speed  Warranty  remains  in  effect  for  the  Warranty  Period  and  is  prorated  on  the  same  schedule  as  the  Standard  Lifetime  Limited  Warranty.    STANDARD  LIFETIME  LIMITED  WARRANTY    For  the  first  ten  years  from  the  date  of  Product  installation  on  the  Property,  Onduline  will  furnish  replacement  material  for  100%  of  the  defective  Product.    After  ten  years,  (i)  Onduline  will  either  provide  Owner  with  replacement  Product  or  reimburse  the  reasonable  cost  of  replacement  products  at  Onduline’s  discretion,  and  (ii)  the  amount  of  replacement  Product  or  the  reimbursement  will  be  reduced  to  reflect  the  use  already  received  from  the  original  Product  according  to  the  

Amortization  Schedule.    If  the  Property  is  a  single  family  detached  residence  and  the  Lifetime  for  the  Owner  exceeds  30  years,  Onduline’s  responsibility  will  be  20%  for  the  remainder  of  the  Lifetime.    Onduline  will  not  pay  for  tear  off  or  disposal  of  Product  under  the  Standard  Lifetime  Limited  Warranty.        AMORTIZATION  SCHEDULE    

Warranty  Months  

Coverage  

0  –  120   100%  121  –  156   90%  157  –  192   80%  193  –  228   70%  229  –  264   60%  265  –  300   50%  301  –  336   40%  337  –  360   30%  361+   20%  

 VOIDING  OF  THE  WARRANTY    The  Standard  Lifetime  Limited  Warranty  and  the  Wind  Speed  Warranty  shall  be  void  if  any  of  the  following  conditions  exist:      1)    The  Product  is  installed  outside  North  America.  2)    Any  defect  in  the  Product  resulted  from:    (a)    any  failure  or  defect  in  the  building  or  substructure  to  which  the  Product  is  attached  including  but  not  limited  to  (i)  improper  design  of  the  structure,  (ii)  construction  error,  (iii)  settling,  shifting,  distorting,  or  movement  of  the  walls  or  foundation  of  the  structure.    (b)    extraordinary  wear  and  tear  including  but  not  limited  to  (i)  acts  of  god  such  as  lightning,  hurricane,  or  tornado  that  affect  the  building  or  substructure;  (ii)  damage  from  hail,  mold,  moss,  algae,  fungus,  lichen,  acid  rain,  contaminants  both  organic  and  synthetic;  (iii)  misuse,  neglect  or  improper  storage  or  handling  of  the  Product  before,  during  or  after  the  installation.    (c)    moisture  accumulation  caused  by  contact  with  damp  or  wet  insulation  or  other  absorbent  materials.    (d)    improper  or  insufficient  ventilation  of  the  roof.    (e)    deterioration  of  ONDUVILLA’s  painted  surface  caused  by  organic  or  inorganic  materials  on  the  roof.    (f)    foot  traffic  on  the  roof  or  damage  caused  by  objects  such  as  tree  branches,  etc.  falling  on  the  roof.    (g)    alteration  of  the  Product  without  the  prior  written  consent  of  Onduline.  

Page 83: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA  by  ONDULINE  NORTH  AMERICA,  INC.  Corrugated  Shingle  and  Accessory  Lifetime  Limited  Warranty    

  Page  2  of  3  

 

(h)    failure  to  install  in  accordance  with  Onduline’s  published  installation  instructions.    3)    The  Product  surface  coating  is  not  maintained  so  as  to  completely  cover  the  Product  throughout  the  Warranty  Period.    4)    The  Owner  fails  to  supply  Onduline  with  samples  and  photographs  of  the  allegedly  defective  Product,  which  Onduline  deems  sufficient  to  illustrate  the  failure,  or  the  Owner  removes  the  Product  before  giving  Onduline  a  reasonable  opportunity  to  examine  the  Product.        HOW  TO  MAKE  A  WARRANTY  CLAIM    Owner  must  submit  any  claims  under  the  applicable  warranty  in  writing  prior  to  the  expiration  of  the  Warranty  Period  together  with  proof  of  purchase  to:  Onduline  North  America,  Inc.    Customer  Services    4900  Ondura  Drive  Fredericksburg,  VA  22407  Phone  1-­‐800-­‐777-­‐7663.    DISCLAIMER    Under  the  Warranty,  the  Product  is  only  warranted  (i)  to  be  free  from  defects  in  workmanship  and  material  and  (ii)  to  withstand  wind.    ONDULINE  MAKES  NO  OTHER  WARRANTY  OF  ANY  KIND  EXPRESS  OR  IMPLIED.    ANY  IMPLIED  WARRANTIES  OF  MERCHANTIBILITY  OR  FITNESS  FOR  A  PARTICULAR  PURPOSE  WHICH  EXCEED  THE  OBLIGATIONS  SET  FORTH  IN  THIS  WARRANTY  ARE  HEREBY  DISCLAIMED  BY  ONDULINE.    The  Product  is  provided  by  Onduline  only  on  the  terms  set  forth  herein  and  any  alternative  or  conflicting  term  in  any  purchase  order,  confirmation  or  other  acceptance  delivered  by  an  Owner  or  Installer  are  hereby  rejected.    No  representative,  employee,  distributor  or  dealer  of  Onduline  has  the  authority  to  make  or  imply  any  representation,  promise  or  agreement  which  in  any  way  varies  the  terms  of  this  Warranty.    Some  states  do  not  allow  limitations  on  how  long  an  implied  warranty  lasts,  so  the  Warranty  Period  limitation  may  not  apply  to  you.    SOLE  REMEDY    Onduline’s  only  liability  under  this  Warranty  or  in  any  action  based  upon  this  Warranty,  contract,  negligence  (of  Onduline,  its  agents  or  employees),  strict  product  liability  or  otherwise,  is  limited  to  the  repair  or  replacement,  at  

Onduline’s  option,  of  Product  that  Onduline  deems  defective.    The  Owner  and  Onduline  expressly  agree  that  the  remedy  of  repair  or  replacement  of  the  defective  Product  is  the  exclusive  and  sole  remedy  available  from  Onduline.    COMPLIANCE  The  Owner  is  responsible  for  verification  that  the  Product  is  compliant  with  state  and  local  regulations  and  standards  that  are  relevant  to  the  Property  including  but  not  limited  to  building  codes  and  building  permit  requirements.  Onduline  will  provide  at  Owner’s  request  all  certification  information  available  for  the  Product.    NO  CONSEQUENTIAL  DAMAGES  ONDULINE’S  LIABILITY  TO  AN  OWNER  TO  WHOM  THIS  WARRANTY  EXTENDS  SHALL  NOT  EXCEED  ONDULINE’S  SALE  PRICE  FOR  THE  PRODUCT  AND  ALLOWANCES  AS  SET  OUT  ABOVE.    ONDULINE  SHALL  NOT  BE  LIABLE  FOR  INCIDENTAL,  SPECIAL,  PUNITIVE  OR  CONSEQUENTIAL  DAMAGES  RESULTING  FROM  ANY  FAILURE  OR  DEFECT  IN  THE  PRODUCT,  INCLUDING  BUT  NOT  LIMITED  TO  LOSS  OF  ANY  REVENUE  OR  OTHER  ECONOMIC  LOSS.    Some  states  do  not  allow  the  exclusion  or  limitation  of  incidental  or  consequential  damages,  so  the  above  limitation  may  not  apply  to  you.    If  any  portion  of  this  document  shall  be  held  ineffective  or  void,  for  any  reason,  the  remainder  shall  remain  in  effect.    GOVERNING  LAW      This  Warranty  shall  be  interpreted  under  Virginia  law  and  any  legal  action  relating  to  the  warranty  shall  be  brought  only  in  Virginia  courts.    This  Warranty  gives  you  specific  legal  rights,  and  you  may  also  have  other  rights  which  vary  from  state  to  state.        

Page 84: ONDUVILLA · between the overlapping guides At eaves drive fasteners on top of the corrugations above the overlapping guides Closure Strips 12.5” d o be 10.625” EAvES Leave a

ONDUVILLA  by  ONDULINE  NORTH  AMERICA,  INC.  Corrugated  Shingle  and  Accessory  Lifetime  Limited  Warranty    

  Page  3  of  3  

 

 

ONDUVILLA  by  Onduline  North  America,  Inc.  

REGISTRATION  FORM  

PROPERTY  OWNER  

Owner  Name:  ________________________________________________________________  

Address:  ________________________________________________________________  

City:                  State:  __________  Zip:  ____________________  

Phone  Number:              

E-­‐mail:                  

 

PROPERTY  ADDRESS  

Address:                      

City:                  State:  __________  Zip:  ____________________  

Type  of  Structure  (circle  one)        Home        Commercial        Other  :______________________________  

New  or  Re-­‐Roof:  ______________    Building  Use  :  ____________________________  

 

PRODUCT  INFORMATION  

Date  of  Purchase:  _______________________      Date  of  Install  :              

Number  of  Shingles  Installed:  ______________      Color  :  ___________________________  

 

CONTRACTOR  INFORMATION  

Company  Name:  ________________________________________________________________  

Address:                      

City:                  State:  __________  Zip:  ____________________  

Phone  Number:            

E-­‐mail:                  

 

Comments:  ________________________________________________________________________________________