oil well potential test, completion or …
TRANSCRIPT
RAILROAD COMMISSION OF TEXAS1701 N. Congress
P.O. Box 12967Austin, Texas 78701-2967
OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG
Form W-2Status:Date:Tracking No.:
06/04/2015
Submitted
132374
OPERATOR INFORMATION
WELL INFORMATION
Operator Name:Operator Address:
Operator No.:
FILING INFORMATION
API No.:Well No.:Lease Name:RRC Lease No.:Location:
Latitude:This well is located
which is the nearest town in the county.
Longitude:
Field No.:Field Name:RRC District No.:County:
miles in adirection from
COMPLETION INFORMATION
Purpose of filing:Type of completion:
Type of PermitPermit to Drill, Plug Back, or DeepenRule 37 Exception
Fluid Injection PermitO&G Waste Disposal PermitOther:
Date Permit No.
Spud date:
Date plug back, deepening, recompletion, ordrilling operation commenced:
Number of producing wells on this lease inthis field (reservoir) including this well:
Total number of acres in lease:
Total depth TVD (ft.):
Plug back depth TVD (ft.):
Was directional survey made other thaninclination (Form W-12)?
Recompletion or reclass?Type(s) of electric or other log(s) run:
Multiple completion?
Is Cementing Affidavit (Form W-15) attached?Rotation time within surface casing (hours):
Plug back depth MD (ft.):
Total depth MD (ft.):
reservoir (ft.):Distance to nearest well in lease &
drilling operation ended:Date plug back, deepening, recompletion, or
Date of first production after rig released:
Elevation (ft.):
10/26/2014
OXY USA INC. 630591KELLEY MONTGOMERY 28TH FLOOR PO BOX 4294 HOUSTON, TX 77024-0000
42-003-46580 320LH
SAINT ANDREWS UNIT
45203 Section: 3, Block: 3, Survey: UL, Abstract: U50
ANDREWS08
SAINT WILMA (STRAWN)
79735500
7.5 NE
ANDREWS,
Initial Potential
New Well
79085409/24/2014
10/26/2014 11/24/2014
12/23/2014
130
6089.93
9528 16891
Yes
Neutron/Density logs (combo of tools)
299.0
3079 GL
87.0Yes
No No
Electric Log Other Description:
Well Type: Producing Completion or Recompletion Date: 12/23/2014
Location of well, relative to nearest lease boundaries Noof lease on which this well is located: 7783.0 Feet from the Line andNorth
1290.0 Feet from the West Line of the
Lease.ST ANDREWS UNIT
Off Lease :
Field & Reservoir Gas ID or Oil Lease No. Well No. Prior Service TypeFORMER FIELD (WITH RESERVOIR) & GAS ID OR OIL LEASE NO.
PACKET: N/A4Page 1 of
W2: N/A
GAU Groundwater Protection Determination
SWR 13 Exception
FOR NEW DRILL OR RE-ENTRY, SURFACE CASING DEPTH DETERMINED BY:Depth (ft.): Date:
Depth (ft.):
1700.0 09/30/2010
INITIAL POTENTIAL TEST DATA FOR NEW COMPLETION OR RECOMPLETIONDate of test:Number of hours tested:Was swab used during this test?
Oil (BBLS):Gas - Oil Ratio:
Gas (MCF):Oil (BBLS):
Flowing Tubing Pressure:
Gas (MCF):
Oil produced prior to test:Choke size:Production method:
Oil Gravity - API - 60.:Water (BBLS):
PRODUCTION DURING TEST PERIOD:
CALCULATED 24-HOUR RATE
Water (BBLS):
Casing Pressure:
03/06/2015 Pumping
24No 20000.00
642.00
270
242
642.0
42.5
270
242
376
CASING RECORD
Row
CasingSize(in.)
Type ofCasing
HoleSize(in.)
SettingDepth
(ft.)
Multi -Stage ToolDepth (ft.)
Multi -Stage ShoeDepth (ft.)
CementClass
CementAmount(sacks)
SlurryVolume(cu. ft.)
Top ofCement
(ft.)
TOCDetermined
By1 Surface 13 3/8 16 1765 C 910 1483.0 Circulated to Surface0
2 Intermediate 9 5/8 12 1/4 8687 C, H 1660 3762.0 Calculation1500
3 Conventional Production 5 1/2 7 7/8 16891 C 780 2061.0 Calculation7700
LINER RECORD
RowLiner
Size (in.)CementClass
CementAmount(sacks)
SlurryVolume(cu. ft.)
Top ofCement
(ft.)TOC
Determined ByHole
Size (in.)Liner
Top (ft.)Liner
Bottom (ft.)
N/A
TUBING RECORD
Row Size (in.) Depth Size (ft.) Packer Depth (ft.)/Type
1 2 7/8 8686 /
PRODUCING/INJECTION/DISPOSAL INTERVAL
Row Open hole? From (ft.) To (ft.)1 No 16635.0L1 10075
ACID, FRACTURE, CEMENT SQUEEZE, CAST IRON BRIDGE PLUG, RETAINER, ETC.
Row Type of Operation Amount and Kind of Material Used Depth Interval (ft.)
Was hydraulic fracturing treatment performed?
Is well equipped with a downhole actuation
Production casing test pressure (PSIG) prior to
Has the hydraulic fracturing fluid disclosure beenreported to FracFocus disclosure registry (SWR29)?
If yes, actuation pressure (PSIG):
Actual maximum pressure (PSIG) during hydraulic
Yes
Nosleeve?
Yes
fracturing: 7342hydraulic fracturing treatment: 7200
4Page 2 of
1 Fracture 51,000 GAL 15% HCL 1663510075
FORMATION RECORD
Formations Depth TVD (ft.) Depth MD (ft.)Is formation
isolated?Encountered Remarks
YATES 3362.0 Yes3362.0Yes
SEVEN RIVERS Yes TOC=0No
QUEEN 4434.0 Yes4434.0Yes
GRAYBURG 5044.0 Yes5044.0Yes
SAN ANDRES - CO2 FLOOD, HIGHFLOWS, H2S, CORROSIVE
5234.0 Yes5238.0Yes
HOLT Yes TOC=0No
GLORIETA Yes TOC=0No
TUBB Yes TOC=0No
CLEARFORK 7105.0 Yes7109.0Yes
PERMIAN DETRITAL Yes TOC=0No
LEON Yes TOC=0No
WICHITA ALBANY Yes TOC=0No
SPRABERRY 8441.0 Yes8535.0Yes
DEAN No NOT DRILLEDNo
WOLFCAMP No NOT DRILLEDNo
CANYON No NOT DRILLEDNo
PENNSYLVANIAN No NOT DRILLEDNo
MCKEE No NOT DRILLEDNo
STRAWN No NOT DRILLEDNo
FUSSELMAN No NOT DRILLEDNo
DEVONIAN No NOT DRILLEDNo
SILURIAN No NOT DRILLEDNo
ELLENBURGER No NOT DRILLEDNo
Do the producing interval of this well produce H2S with a concentration in excess of 100 ppm (SWR 36)?
Is the completion being downhole commingled (SWR 10)?
No
No
REMARKS
4Page 3 of
RRC REMARKSPUBLIC COMMENTS:
CASING RECORD :
TUBING RECORD:
PRODUCING/INJECTION/DISPOSAL INTERVAL :
ACID, FRACTURE, CEMENT SQUEEZE, CAST IRON BRIDGE PLUG, RETAINER, ETC. :
POTENTIAL TEST DATA:
OPERATOR'S CERTIFICATIONPrinted Name:Telephone No.: Date Certified:
Title:Amanda Maxian Regulatory Coordinator
(713) 840-3036 04/08/2015
4Page 4 of
STATEMENT OF PRODUCTIVITY OF ACREAGE ASSIGNED TO PRORATION UNITS Form P-15
The undersigned states that he is authorized to make this statement; that he has knowledge of the
OPERATOR
LEASE
,
, No.WELL
facts concerning the
; that such well is
completed in the Field, County,
Texas and that the acreage claimed, and assigned to such well for proration purposes as
authorized by special rule and as shown on the attached certified plat embraces
acres which can reasonably be considered to be productive of hydrocarbons.
- CERTIFICATE -
I declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I am autho-
rized to make this report, that this report was prepared by me or under my supervision and direction,
Date 04/08/2015 Signature Amanda Maxian
Telephone (713) 840-3036
AREA CODETitle Regulatory Coordinator
OXY USA INC.
SAINT ANDREWS UNIT 320LH
ANDREWS
160.0
SAINT WILMA (STRAWN)
This facsimile P-15 was generated electronically from data submitted to the RRC.
Tracking No.: 132374
RAILROAD COMMISSION OF TEXASOil and Gas Division
FORM L-1 ELECTRIC LOGSTATUS REPORT
Instructions
When to File Form L-1: Where to File Form L-1:� with the appropriate Commission district office� with Forms G-1, W-2, and GT-1 for new and deepened gas, oil, and
geothermal wells
� with Form W-3 for plugged dry holes� when sending in a log which was held under a request for confidentiality and the period for confidentiality has not yet expired.
Filling out Form L-1:� Section I and the signature section must be filled out for all wells� complete only the appropriate part of Section II
Type of log required:When is Form L-1 NOT required:
� with Forms W-2, G-1, and GT-1 filed for injection wells, disposal wells, water supply wells, service wells, re-test wells, re- classifications, and plugbacks of oil, gas or geothermal wells� with Form W-3 for plugging of other than a dry hole
� any wireline survey run for the purpose of obtaining lithology, porosity, or resistivity information� no more than one such log is required but it must be of the subject well� if such log is NOT run on the subject well, do NOT substitute any other type of log; just select Section II, Part A below
This facsimile L-1 was generated electronically from data submitted to the RRC.
SECTION I. IDENTIFICATION
OperatorName:
District No.
CompletionDate:
Drilling PermitNo.
FieldName
LeaseName
County
Lease/IDNo.
WellNo.
APINo. 42-
SECTION II. LOG STATUS (Complete either A or B)
08 12/23/2014
ANDREWS
790854SAINT WILMA (STRAWN)
OXY USA INC.
SAINT ANDREWS UNIT 45203 320LH
003-46580
A. BASIC ELECTRIC LOG NOT RUN
B. BASIC ELECTRIC LOG RUN. (Select one)
1. Confidentiality is requested and a copy of the header for each log that has been run on the well is attached.
2. Confidentiality already granted on basic electric log covering this interval (applicable to deepened wells only).
3. Basic electric log covering this interval already on file with Commission (applicable to deepened wells only).
4. Log attached to (select one):
(a) Form L-1 (this form). If the company/lease name on log is different from that shown in Section I, please enter name on log here:
Check here if attached log is being submitted after being held confidential.
(b) Form P-7, Application for Discovery Allowable and New Field Designation.
(c) Form W-4, Application for Multiple Completion:
Well No(s).
Signature Title
Name (print) Phone Date
-FOR RAILROAD COMMISSION USE ONLY-
X
X
04/08/2015
Lease or ID No(s).
Regulatory Coordinator
(713) 840-3036
Amanda Maxian
OXY USA INC.
Tracking No.: 132374