-1- ODEON / TOILET/SQUAT SENSOR K-744T-C05(AC/ ) INSTALLATION INSTRUCTIONS K-744T(DC/ ) · · · Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. Follow the sections that pertain to your particular installation. This will help you avoid costly mistakes. In addition to proper installation, read all operation and safety instructions. All information in these instructions is based upon the latest product information available at the time of publication. Kohler China reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. These instructions contain important care, cleaning, and warranty information - please leave instructions for the consumer. · · · - · · · · · · · · · · · · · · · Open end/adjustable wrenches Tape measure Basin wrench Pipe wrench Square Level Pliers Socket wrench with sockets Philips driver Seal tape Special wrenches Connection wire Wire cutter Insulation tape Bushing · · · · · · · · · · · · · · · / RECOMMENDED TOOLS AND MATERIALS RECOMMENDED TOOLS AND MATERIALS SENSOR SPECIFICATIONS SENSOR SPECIFICATIONS Model 744T(DC)/744T-C05(AC) Power AAA size alkaline batteries( 2) (744T) 220V AC 50/60Hz (744T-C05) 744T( )/744T-C05( ) 2 7 (AAA 2)(744T) 220V AC 50/60Hz (744T-C05) 0.10~0.55MPa 4 6 8 11 :1 ~55 1 ~45 0.05~0.86MPa 100cm ( ) 3~8 G1 G1-1/2 24 0.1~0.55MPa ( ) 25mm Liter per flushing Water pressure at 0.10~0.55 MPa: 4 L, 6 L, 8 L,11 L(adjustable) Temperature Environmental temperature: 1 ~55 Water temperature: 1 ~45 Starting pressure 0.05~0.86MPa Sensing distance Flushing delay Connect dimension Protective flushing Recommended working pressure 3~8 seconds after user leave Inlet pipe G 1 , Outlet pipe G 1-1/2 . Auto flush once every 24h if unused Sensor inlet dynamic pressure: 0.1~0.55MPa, recommended inner diameter of water supply ( including water meter, valve, etc. ) no less than 25 mm. Within 100cm from sensing window (along the direction of transmitting angle) , 2007 Copyright Kohler China Ltd., 2007 18 E 201206 1046837-T01-D

Upload: others

Post on 21-Feb-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

-1-

ODEON/

TOILET/SQUAT SENSOR

K-744T-C05(AC/ )

INSTALLATION INSTRUCTIONS

K-744T(DC/ )

Please read these instructions carefully to familiarizeyourself with the required tools, materials, and installationsequences. Follow the sections that pertain to yourparticular installation. This will help you avoid costlymistakes. In addition to proper installation, read alloperation and safety instructions.All information in these instructions is based upon thelatest product information available at the time ofpublication. Kohler China reserves the right to makechanges in product characteristics, packaging, oravailability at any time without notice.These instructions contain important care, cleaning, andwarranty information - please leave instructions for theconsumer.

� -

Open end/adjustable wrenchesTape measureBasin wrenchPipe wrenchSquareLevelPliersSocket wrench with socketsPhilips driverSeal tapeSpecial wrenchesConnection wireWire cutterInsulation tapeBushing

/

RECOMMENDED TOOLS AND MATERIALSRECOMMENDED TOOLS AND MATERIALS

SENSOR SPECIFICATIONSSENSOR SPECIFICATIONS

Model 744T(DC)/744T-C05(AC)

PowerAAA size alkaline batteries( 2)(744T)

220V AC 50/60Hz (744T-C05)

744T( )/744T-C05( )

2 7 (AAA 2)(744T)

220V AC 50/60Hz (744T-C05)

0.10~0.55MPa4 6 8 11

: 1 ~55 1 ~45

0.05~0.86MPa

100cm ( )

3~8

G1 G1-1/2

24

0.1~0.55MPa( )

25mm

Liter per flushingWater pressure at 0.10~0.55 MPa: 4 L,6 L, 8 L,11 L(adjustable)

TemperatureEnvironmental temperature: 1 ~55Water temperature: 1 ~45

Starting pressure 0.05~0.86MPa

Sensing distance

Flushing delay

Connect dimension

Protective flushing

Recommendedworking pressure

3~8 seconds after user leave

Inlet pipe G 1 , Outlet pipe G 1-1/2 .

Auto flush once every 24h if unused

Sensor inlet dynamic pressure:0.1~0.55MPa, recommended innerdiameter of water supply ( includingwater meter, valve, etc. ) no less than25 mm.

Within 100cm from sensing window(along the direction of transmitting angle)

, 2007

Copyright Kohler China Ltd., 2007

18 E 201206

1046837-T01-D

Page 2: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

1.

2.

3. 27

37

4. ( K-8750 )

5. K-4330 K-8750

L 70cm

6.

7.

8.

o

o

30cm 30cmNote: 1. The sensing distance in the table is measured with a

30 30cm white or black board as the reflectingsurface.

2. The user may set the amount of water per flushaccording to the specifications of the specific toilet.

4. To ensure an effective flushing preformame, pleaseturn the adjusting bolt properly according to actualusing conditions when the product is used with toilet( such as K-8750, etc.)

2

3 .The infrared transmiting angle is 27 downward , 37when used with angle-comerting piece.

.

o o

5 The angle-converting piece is used only with K-4330,K-8750 or for toilets with the length less than 70cm.

6. Do not discard the special wrench when theinstallation is complete. It will be helpful for qualifiedmaintenance personnel to repair the outletconnection assembly and the vacuum breaker.

7. Setup switch unit is used only during the setup offlash volume.

8. The slurry mold is used only when install the valvebox.

-2-1046837-T01-D

Page 3: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

-3-

PRODUCT PAGE

O-RingO

11Main ValveCore Assy.

Spring

Check Valve Cover

2Sensor Lens 8

Bracket, Button

Battery Box Assy.

744T Use Only744T

5*Angle-ConvertingPiece, Optional

Control BoxFixed Plate

3Control Box a Assy.W/Battery Box

9Fixed Plate Assy.

Manual Lever Assy. ManuallyOperated Line

Outlet Shield

Valve Body

Inlet Connection Assy.

*Special Wrench*

26*Switch Assy.*

SealingShield

Adjustment Nut

Filter Cover

10Main Filter

Filter Assy.

Screws

Pressing Board1

Cover

6Button

Bracket, Battery Box

*

19Manual ValveCover Assy. Driving Valve Assy.

15SolenoidValve Assy.

13Double HeadValve Cover

17Membrane Assy.

16Membrane Spring

Main CheckValve Spring

Stop Valve Assy.

Double Valve Core Assy.

Valve CoreCoverW/O-Ring

( O-Ring)

Outlet ConnectorAssy.

Angle

Screws

Screws

Screws

Screws

Screws

Valve CoreMembrane

Screws

Screws

12Valve CoreMembrane

Center Unit Assy.

Screws

Screws

Screws

7Spring, Button

20Sealing Bracket Assy.

Filter

18Membrane Bracket,W/ O-Ring

*Slurry Mold*

Valve Box

O-RingO

O-RingO

StraighteningDevice-1

-122

Turbine Assy.

21Hall Hook Assy.

23Hall Box Assy.

Speed DetectorConnector(Three-Pin)

( )

24VacuumBreaker Assy.

25

O-RingO

SpeedDetectorAssy.

Outlet Pipe

4

14

. 1046367-SC/CP 1046368 1046369 1046371 1046372 1046377-SC/CP 1046378 1046379 1046382

1 2 3 4 5 6 7 8 9

. 1046394 1346399 1046400 1046403 1045457 1045452 1046404 1046405 1046406

10 11 12 13 14 15 16 17 18

. 1046407 1046408 1046414 1046415 1046416 1046417 1046419 1046424

19 20 21 22 23 24 25 26

AC

16306T-NA744T-C05 Use Only744T-C05

Connector

1046837-T01-D

Page 4: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

-4-

ROUGHING-IN

UNIT: mm

Table of installation positions for toilets (Used with K-4350, K-4368, K-4349, K-4367)

( K-4350, K-4368, K-4349, K-4367)

L

H

700 L 730

640 H 670 670 H 700 700 H 730 730 H 760 760 H 790

730 L 760 760 L 790 790 L 820 820 L 850

K-4350K-4368

K-4349K-4367

105+300 158

H

15

8

L

CL OF OUTLET

G1-1/2 SPUDG1-1/2

G1-1/2

105+300

158

15

8

L

CL OF OUTLET

HG1-1/2

G1-1/2 SPUDG1-1/2

105+300 158

H

158

CL OF OUTLET

L

G1-1/2

G1-1/2 SPUDG1-1/2

K-4330 K-8750

Used with K-4330, K-8750, or when toilet installation length less than 70 cm, must install angle-converting piece.

K-4330, K-8750 L 70cm,

L

H

540 L 570

570 H 600 600 H 630 630 H 670 670 H 700 700 H 740

570 L 600 600 L 630 630 L 660 660 L 700

H

158

158

G1-1/2

CL OF OUTLET

L

105+300

1046837-T01-D

Page 5: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

+300105

H

L

a. L H

b. L H

e.

c. 540 L 850

2430T-NA

2429T-NA 2429T-

SA-NA

d. K-4330, K-8750

L 700mm (

H)

Notice: a. To ensure sensing effect, the dimensions

for L & H should be strictly observed.

b. Do not use if dimension for L and H is not

in table.

c. When toilet length between 540mm and

850mm, please use 2430T-NA as top inlet,

please use 2429T-NA as rear inlet; When

squat, please use 2429T-SA-NA as rear

inlet.

d. When used with K-4330, K-8750 or toilet

installation length less than 700mm, please

use angle-converting piece. (See step H)

e. To comply with above tables, you may cut

either end of the connecting pipe.

-5-

Table of installation positions for squats

CL OF OUTLET

L

H

700 L 730

640 H 670

730 L 760

670 H 700

760 L 790

700 H 730

790 L 820

730 H 760

820 L 850

760 H 790

1046837-T01-D

Page 6: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

-6-

INSTALLATION

1

Notice:

.

a.

See the figureright for rough-in dimension requirement.While installing 744T-C05(AC),chisel out the slot indicatedin the dot line area of figure right for installation of bushing.

Determine the installation location per rough-in dimensionsand the table of installation position. Chisel out a slot andinstall the supply tubes. Then flush the supply tubes. Thedepth of the slot is not less than 105 mm, see the figure tothe right for rough-in dimension requirement.

Installation that fails to accord with theinstallation position or rough-in dimensionsmay result in false operations or nooperations.

b. No light shall enter or be reflected into thesensing window.

c. reflectible objects in front of the sensingwindow (e.g., mirror, polishing stainlesssteel and some other polished plates).

d. trong ultraviolet radiation orelectromagnetic field nearby.

No

No s

1.

105mm

744T-C05( )

a.

b.

c. (

)

d.

Supply Tube (recommended innerdiameter is more than 25 mm)

( 25mm)

Battens

Nut

2. Remove the dust-proof cover from the inlet connection of

the flushing valve. Then place the flushing valve into the

slot, adjust its level and square with battens and connect

the inlet tubes. Screw down the nut at the outlet position.

Refer to the specific rough-in of different toilets/squats for

the connection of outlet fittings.(You need to flush the pipe

before connect to the toilet sensor.)

2.

/

(

)

58

Installation Side

100

100

100 100

130

130

Install bushing

Connector

Connect control box whileinstalling 744T-C05

744T-C05

Connect DC wiring terminal

Outer diameter of bushingis no more than 25mm

25mm

1046837-T01-D

Page 7: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

Please directly reference to Step 3 when installing 744T(DC).

Please match 16306T-NA AC power unit when installing744T-C05 (AC).

a. Outlet of AC power unit upward prohibited.b. Do not connect 220V AC power supply to DC wiring

terminal.c. Do not damage the covering of AC power unit or

remove screws to avoid leakage.

CAUTION:

744T( ) 3

744T-C05( ) 16306T-NA

a.

b. 220V

c.

A. 1

A. Fig. #1: AC power unit connected to electric control box by

connection wire.

B. When installing the power unit on the ceiling, please layout

bushing according to Fig. #2 and thread wire through the

bushing.

Fig. #2: Connection sketch while installing power unit on the

ceiling.

One AC power unit can supply two sensors

at most.

CAUTION:

B.

2

-7-

Outlet downwardsOutlet upwards

Connect tosensor

Connect to ACPower supply

Connect to ACPower supply

Connect tosensor

AC

16306T-NAAC Power Unit

Connector

Wire preparedby customer

Connect with the same color ,and protect connect area by insulation tape.

wire

Connector

Fig. #11

AC Power Unit Ceiling

Bushing

Fig. #22

1046837-T01-D

Page 8: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

Notice: a. Because the installation position of the

sensor will affect directly to the future

operation of the sensor, you are

recommended to confirm the correction

position of the sensor after its placement

and fix it.

b. Don't mistake the direction of inlet and

outlet.

c. Don't drop the O-rings.

d. Keep the wire plug-in away from water.

e. Align the center of the flushing valve with

the center of the toilets/squats, and ensure

it parallel with the wall, or will result in the

false operation of the sensor.

f. Do not use any sealant or grease on the

valve or connector and outlet pipe.

g. While more than 3 sets of sensor were

installed in one lavatory, the inner diameter

of main inlet pipe should not be less than

38mm.

h. Do not connect the DC output of AC Power

unit to AC power supply.

i. Do not connect to power supply while

installing. Connection line is not supplied.

AC connection wire with insulating sleeving

is recommended. Wire of which the nominal

section area of conductor is not less than

0.5mm is also recommended. DC

connection line use wire of which the

nominal section area is not less than

0.3mm . It is cut according to acted

installation requirements(The length of cut

wire is recommended less than 10m).

j. The head AC power supply must be

protected with appropriate fuse.

k. Please confirm the AC power supply and

water supply should be shut off before

maintaining the products with AC power

related.

2

2

a.

b.

c.

d.

e. /

,

f.

g. 3

38mm

h.

i.

0.5mm

0.3mm

( 10m)

j.

k.

2

2

-8-1046837-T01-D

Page 9: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

-9-

4. When the slurry turns solid, remove the short screws, pull

out slurry mold, mount the bracket assembly, and secure

with long screws.

4.

ScrewsM4 50

M4 50

3.

Notice:

Gently remove the manual device inside the plastic bag ofvalve box and drive the flushing unit with manual leverassembly. Once it is confirmed that there is no leakageafter the connection of supply tube, put the manual leverassembly to its original place. Mount the slurry mold ontothe valve box and apply slurry into the crevice around thevalve box and smooth the surface.

a. Please confirm the completion of the outletconnection or no leakage during theapplication of water supply.

b. Please avoid breaking the manual lever lineduring this procedure.

c. Avoid the plug-ins from wetting, or this willresult in false operations of the sensor.

Valve Box

Tiles

Slurry Mold

Push here to drive

Manual Lever Assy.

3.

a.

b.

c.

Slurry Mold

ScrewsM4 10

M4 10

105+300

35

1046837-T01-D

Page 10: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

-10-

5.

Notice: a. Don't twist, circle or pull the manual line to

avoid it from broken.

b. Don't adjust the screws on the manual

lever assembly, or it will affect the

operation of the assembly.

Mount the manual lever assembly onto the bracket with

screw.

Manual Lever Assy.Screws

5.

a.

b. ,

6.

Notice:

Don t connect to power supply while installing the cover.

Connect the solenoid valve connector and speed detector

on the control box with the corresponding cords

of the solenoid valve. Install the sensor cover with control

box as shown by the figure:

a. Buckle the sensor cover into the wall slightly above the

bracket assy.

b. Press the sensor cover down along the wall and fit

tightly into the bracket assy.

c. Push upward with basin wrench and rotate clockwise to

lock the sensor cover (rotate counterclockwise to

remove the sensor cover).

a.

b.

c. Prevent damage or drop of the cover or

break the cord during this procedure.

d. Please observe the indicator from the

bottom of the sensor cover upwards.

connector

connectorEnsure the tightness of the to

avoid them from wetting

Wear clean gloves when installing the

sensor cover to avoid surface injury by

cement or sand

.

.

'

a

b

Solenoid Valve( )

Connector

Speed Detector( )Connector

Indicator

6. ,

a.

b.

c. (

)

a.

b.

c.

d.c

90o

1046837-T01-D

Page 11: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

7.

Notice:

After installing the sensor cover, observe the cover if it isupright and its centerline is aligned with that of the toiletand squat. If any deviation occurs, remove the cover andloosen the locking screws of the fixed bracket. Adjust thefixed bracket for correctness. Fasten the screws andreinstall the sensor cover after any adjustment.

The central position and correctness of thesensor will affect the proper operation of thesensor.

7. /

Screws

Angle-Coverting Piece

Screws

8.

Notice:

When used with K-4330, K-8750 or toilet length no more

than 70cm , the angle-converting piece is necessary to

ensure the best performance of sensor.

a.

a.

b.

Otherwise may

cause misaction of the sensor.

Remove the sensor cover (see Step F).

b. Unscrew the screws of fixed plate for control box.

c. Add an angle-converting piece in front of the sealing

shield as shown.

d. Reinstall the control box and its fixed plate.

When operating, tighten the screws after

the device is in its proper place.

Be careful not to miss or damage the

sponge pad of the angle-converting piece.

8. K-4330 K-8750 L

70cm

a. ( F)

b.

c.

d.

a.

b.

INSTALLATION IN OTHER METHODSINSTALLATION IN OTHER METHODS

Prefabricated Board Decorating Panel

a. Installation On Prefabricated Board b. Installation On Decorating Panel

105+300

35 35

105+300

Notice: For these two installation forms, the sensor must be installed according to rough-in.

-11-1046837-T01-D

Page 12: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

USER S GUIDEUSER S GUIDE

Automatic Adjustment of Sensing Distance

The accuracy of this section s steps will affect

the sensing performance.

The sensing distance of this product is set at within 100cm

away from the sensing window along the direction of

transmitting angle (with a 30cm x 30cm white board as the

reflecting surface) in the factory with an infrared transmitting

angle of about 27 (37 when an angle-converting piece

installed)downward. When the power is applied, the product

is in the status of automatically adjusting its sensing distance

during the first ten minutes, when the sensor is in an

environment of normal operations. Also during this period, all

the facilities have been installed in the toilet. Proceed with

this process so that you can correctly adjust its sensing

distance.

'

-12-

Toilet Cover

Toilet Seat

1. Preparations

a. Pull down the toilet seat, if there is a cover, please lift it asshown in picture above.

b. Remove any unwanted materials near the toilet bowl.c. Set up the flashing volume of the sensor via the switches of

the flushing volume (see the following setup of the flashingvolume).

2. Procedures (Please finish below

steps within 5 mins)

a.

b. Unplug 3-pin connector of speed detector, then connect

switch assy. and control box with 3-pin connector. Unplug

them after 10 seconds, and replug speed detector and

control box with 3-pin connector.(Please ignore this step if

the flush volume is the same as default setting.)

c. Install the sensor cover.

d. Close the door of the toilet.

e. Wait 5 mins, the auto adjustment of sensing distance will

complete.

Reomove the sensor cover. While installing 744T(DC), take

out the battery box from the back of the cover and put

batteries into the box. Connect battery box assy to control

box. While installing 744T-C05(AC),connect AC power unit

to control box, and then power on.

1.

a.

b.

c. (

)

2. ( a~e 5

)

a. 744T

744T-

C05

b.

10

(

)

c.

d.

e. 5

100cm ( 30cm 30cm )

27 ( 37 )

10

1046837-T01-D

Page 13: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

3. Setup of Flushing Volume

The default flushing volume of this product is followed (4L, 6L).

SW1 has set as ON, SW2 and SW3 as OFF. Users can set

the flushing volume as needed per the table below by turning

on the right switch of the setup switch assembly. However,

these operations should be completed within five minutes

after power on. Power on and ten seconds after the

connection of the setup switch assembly and control box, the

setup of the flushing volume is complete. After the setup,

keep safe the setup switch assembly.

3.

(4L 6L)

SW1 ON SW2 SW3 OFF

5

10 , (

)

1 2 3 4ON

Sw4 is emptySw4

*Setup Switch Unit*

ON(dual flushing mode)

For liquidwastes only

For solidwastes

Flushvolume

Flushvolume

OFF(single flushing mode)

Water per flush (L)

SW3 SW2

SW1

OFF

OFF

ON

ON

OFF

ON

OFF

ON

4

6

6

8

6

6

8

11

4

6

8

11

SW3 SW2

SW1

OFF

OFF

ON

ON

OFF

ON

OFF

ON

4

6

6

8

6

6

8

11

4

6

8

11

ON( )

( ) ( )

OFF( )

( )

-13-

Notice: a. After finishing these steps, the toilet sensor

is ready for use.

b. The sensor cover installing must be

finished within five minutes after power on.

If this is not accomplished within 5 minutes,

shut off the power. When the indicator

stops flashing, power on again and repeat

the above steps.

c. Don't mistake the polarity of the batteries

and don't mix the new and used batteries

together.

d. Tighten the screws of the battery box to

avoid the batteries from wetting.

a.

b.

5 5

c.

d.

1046837-T01-D

Page 14: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

Notice: a. If it is necessary to set up again, you mustcut off the power supply. Repeat the abovesteps after the indicator goes out.

b. If sensinng time is less than 1 min, thesensor will flush at liquid wastes onlyvolume automatically.

c. When used with K-4330, the dual flushingmode 4L/6L and single flushing mode 4Lare not recommende

d.When used with squat ,the dual flushingmode 6L/8L and single flushing mode 8Lare recommended.

a.

b. 1

c. K-4330 4L/6L4L

d. 6L/8L8L

4. Manual Flushing

This system can have a good sense toward most of the

clothes. However, it may have abnormal sense to a very small

number of clothes. If this occurs, you may use the mode of

manual flushing. Press the button with your hand to flush the

toilet bowl with water, or loosen the button to stop flushing.

a. The button is a standby device that will be

used when the sensor cannot perform

correctly or the toilet is being repaired. It is

not recommended to use when the sensor

is normally functional.

b. When the sensor cannot function properly,

please refer to the list of troubleshooting on

Page 17.

c. Do not exert too much force to avoid the

manual unit from damaged.

Notice:

Button

4.

: a.

b. (P17)

c .

-14-1046837-T01-D

Page 15: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

-15-

5.

0.10~0.55MPa

5. Adjustment of Flushing Volume

When the water pressure is 0.10 ~ 0.55 MPa, the device may

normally automatically control the flushing volume. If

sometimes splashs, you can reduce the water flow. And if the

flushing peformance is not good, you can enlarge the water

flow. When adjusting, remove the sensor cover and turn the

adjusting bolt for water flow till good flushing and no splash.

Adjusting Bolt

6. Replacement of Batteries(only for 744T)

When the power in the batteries will be exhausted and theindicator in the sensing window continues flashing, thesystem reminds you of replacing the old batteries with newones. When out of power, the indicator will flash every 2seconds and the sensor will not work until new batteries aresupplied. When changing, remove the battery cover and putin new batteries. If the system has been powered off for along time, you must reset the procedure after the replacementof batteries and the system will readjust automatically itssensing distance (refer to the section of automatic adjustmentof sensing distance).

the flash direction of the indicator is downward,so you need to observe along the direction.

Note:

Screws

Batteries Battery Box Cover

Battery Box

6. ( 744T)

2

(

)

1046837-T01-D

Page 16: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

7. Protective Flushing

When the toilet has not been used for a long time, the sensor

will drive the solenoid valve to flush every 24 hours to avoid

the deodorizer and the sewer pipe from drying up.

7.

24

-16-

Toilet & Squat Repair

When repairing, you don t have to dismount the sensor.Cover the sensing window with tape and work with ease.

: use very adhesive tape in case the scarwill be hard to remove and result in falseoperations of the sensor.

Notice Don't

/

Clean the Filter Screen

If the flushing volume reclines sharply after installation orused for a long time with no cause from water pressure, thefilter may need a wash. Turn off the fixed cap with filter-key,take out the filter, clean with a brush and reinstall it.

a. Turn off the water supply or tighten theadjusting bolt before cleaning.

b. Carefully take out the filter when cleaning toavoid foreign materials entering the insideof the valve body.

Notice:

MAINTENANCE

Care & Clean

Keep the sensing window clean. Wipe with soft cloth and mild

cleaner.

a. Do not use dust-removing powder, abrasive

powder or cleaner containing oil, acid or

alkaline ingredient.

b. Do not spray air-refresher, disinfector, or

other deodorizing, cleaning solvent directly

into the sensing window.

c. Keep wire away from water.

d. Don t attack the sensor window.

Notice:

'

a.

b.

c.

d.

Filter

Fixed Cap

1021430Filter-keya.

b.

1046837-T01-D

Page 17: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

-17-

TROUBLESHOOTING

No flushing(Indicator not flashing)

1.2. There is an object within the sensing distance.3. The sensing window needs cleaning.4. The toilet seat is loose.5. The toilet cover (if applicable) is closed.6. Around squat is dirty.

No power or mistake connected.

1.2. Remove the object or reduce the sensing

distance.3. Clean the window.4. Fasten the toilet seat, and follow the

steps for automatic adjustment of thesensing distance again.

5. Open the toilet cover.6. Clean the squat.

Check the power connect.

No flushing or poorflushing while the indicatorcan flash

1. Still in the waiting status2. Adjusting bolt not fully open3. Low water pressure4. Filter is obstructed.

1. Wait for 10 minutes.2. Open the adjusting bolt.3. Improve water supply.4. Clean the filter.

Keep flushing indicator notflashing

Battery indicating lightkeeps flashing and noflushing

1. There are some dirty materials inside the valvebody.

2. The manual unit is damaged.

Out of electricity(Only for 744T)

1. After cleaning the filter, activate the sensorseveral times.

2. Check the manual unit.

Replace batteries(Only for 744T)

Please make following checks before repair:

Symptoms Probable causes Corrective actions

If the trouble remains after above-mentioned actions are taken, please contact with us via distributor.

( )

1.2.3.4.5. ( )6.

1.2.3.4.5.6.

1.2.3.4.

1.2.

( 744T )

1. 102.3.4.

1.

2.

( 744T )

1046837-T01-D

Page 18: ODEON - Kohler Co.resources.kohler.com/plumbing/kohlerindia/pdf/k744cp.pdfc. When toilet length between 540mm and 850mm, please use 2430T-NA as top inlet, please use 2429T-NA as rear

IMPORTANTCONSUMER INFORMATION

-18-

Consumer Responsibilities

1. Do not attack the sensor.

2. Do not directly flush the sensor with water. The sensor isan electronic instrument.

3. Do not let sunlight or other light source enter or bereflected into Sensor Window.

4. Do not hang on the opposite wall any reflective items orinstall light/electronic sensor such as toilet flushing sensor.

5. Do not make Sensor Window near strong ultraviolet orelectromagnetic field.

6. Keep the sensor window clean.The sensor cover can be cleaned by soft rag with neutralliquid detergent.Do not use eradicator, abrasive powder or oil, acid or alkaliliquid detergent.Do not spray air freshener, disinfectant or other kinds ofodious removing, cleaning organic liquid to the sensordirectly.

7. Urinal is designed for use with potable water. Avoid waterthat includes a lot of contaminants or acid/alkali water andimpure water.

8. When AC power unit is connected to 220V AC powersupply, corresponding protective measures should betaken.

9. Please confirm no water penetration at the connectionarea of AC wire, and the connection area is not easy to beaffected by damp.

10. Don t connect power unit to AC power supply until thesensor installation is finished.

11. The head AC power supply must be protected withappropriate fuse.

12. Please confirm the AC power supply and water supplyshould be shut off before maintaining the products withAC power related.

13. All electrical connection must be compliance with relatedregulation and codes.

14. All installation staff should be well familiar with installationinstruction.

1.

2.

3.

4.( )

5.

6.

7.

8. 220V

9.

10.

11.

12.

13.

14.

1046837-T01-D