october 2018 · indore / raipur umesh bhatia 09589344318 [email protected] h.o. and service...

8
OCTOBER 2018 Automation Piyush Patel (Managing Director) Amtech Power Vision AN ISO 9001 : 2015 COMPANY Why Lord Krishna is called as Jagadguru? In the last month we celebrated Shri Krishnashtami, the birthday of our beloved God Shri Krishna. Why this God in particular is called as Jagadguru, the Guru of whole universe? Well there are many reasons for this, but we will consider one of them, in this article. It starts with his childhood. Lord Krishna and his friends used to catch hold of the Makhan, the white butter, which was kept in a pot, located at a height and was not accessible easily. So Krishna had found out a technique of reaching the height, by forming a kind of pyramid, which is famous as Dahi-handi-pyramid. We all Indians know about it. But what lessons does it give to the world? It gives very important corporate lessons: 1. All cannot be on the top. 2. As you rise to the top, the risk also rises. 3. Those who are at the bottom, bear the maximum load, so that someone can reach to the top. 4. If you want to eat Makhan (want to achieve your goal) you have to reach to the top. 5. If you arrange your internal team properly, believe in its strength, then you can achieve your goal with no dependence on any external resources. No doubt, Shri Krishna who was so visionary in his childhood, later became the Lord, who gave Bhagvad Geeta to the world, which is considered as the ultimate knowledge and universal guide for day to day life as well as for the ultimate well-being. Customer’s Voice Field Problem Case Study Motor Control OT-iB Series OT-iB Series Time is life. Wasting time is wasting one’s life. Customer’s Voice You question, we answer Energy saving in Pump AN ISO 9001 : 2015 COMPANY With Our NextGen Technology, Gain Total Control of Your Pulp & Paper Mill

Upload: others

Post on 30-Nov-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OCTOBER 2018 · Indore / Raipur Umesh Bhatia 09589344318 mp@amtechelectronics.com H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Shailesh

OCTOBER 2018

Automation

Piyush Patel (Managing Director)Amtech Power Vision

AN ISO 9001 : 2015 COMPANY

Why Lord Krishna is called as Jagadguru?In the last month we celebrated Shri Krishnashtami, the birthday of ourbeloved God Shri Krishna.Why this God in particular is called as Jagadguru, the Guru of wholeuniverse? Well there are many reasons for this, but we will consider oneof them, in this article. It starts with his childhood. Lord Krishna and hisfriends used to catch hold of the Makhan, the white butter, which waskept in a pot, located at a height and was not accessible easily. SoKrishna had found out a technique of reaching the height, by forming akind of pyramid, which is famous as Dahi-handi-pyramid. We all Indians

know about it. But what lessons does it give to the world? It gives very important corporate lessons:1.All cannot be on the top.2.As you rise to the top, the risk also rises.3. Those who are at the bottom, bear the maximum load, so that someone can reach to the top.4. If you want to eat Makhan (want to achieve your goal) you have to reach to the top.5. If you arrange your internal team properly, believe in its strength, then you can achieve your goalwith no dependence on any external resources.No doubt, Shri Krishna who was so visionary in his childhood, later became the Lord, who gaveBhagvad Geeta to the world, which is considered as the ultimate knowledge and universal guidefor day to day life as well as for the ultimate well-being.

Customer’s Voice

Field ProblemCase Study

Motor ControlElectronics Soft-Starter

MODENORM

ESC UP

DOWN ENTER

GROUP

STOP

RESET

FAULT

RUN

OT-iB Series

Electronics Soft-Starter

MODENORM

ESC UP

DOWN ENTER

GROUP

STOP

RESET

FAULT

RUN

OT-iB Series

Time is life.Wasting time

is wastingone’s life.

Customer’s Voice

You question,we answer

Energy saving in Pump

AN ISO 9001 : 2015 COMPANY

With OurNextGen Technology,

Gain Total Control of YourPulp & Paper Mill

Page 2: OCTOBER 2018 · Indore / Raipur Umesh Bhatia 09589344318 mp@amtechelectronics.com H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Shailesh

CUSTOMER’S VOICE

Page 3: OCTOBER 2018 · Indore / Raipur Umesh Bhatia 09589344318 mp@amtechelectronics.com H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Shailesh

3

FIELD PROBLEM CASE STUDY

Problem Faced:During Harmonic Study we take the readings at PCC (Point of Common Coupling), for Voltage Distortion and Current Distortion.As perIEEE 519-2014 standard, the I-THD, Total Harmonic Distortion for current is the responsibility of consumer and he needs to keep theTDD – Total Demand Current Distortion within the limits, as defined in Table-1 given below. Now to know this limit, we need to know theI /I ratio (Short circuit current to Demand current ratio) at PCC. Hence it is necessary to know the short circuit capacity of theSC L

transmission line, where PCC is connected. Many a times this information is not available with the consumer. Then how it can be foundout?Table-1: IEEE 519-2014 Standard Current distortion limits

The Solution:Let us see how we can find out short circuit capacity of the transmission line, then we can calculate short circuit current I at PCC.SC

Refer to Figure-1.

PART-1

Transformer secondary impedance including reflectedimpedance from primary

= Z1 x (Vs / Vp) + Zs2

Now Y = Vs / Z22

Hence Z2 = Vs / Y2

Zs = Transformer per unit impedance x Z2

Hence Zs = Z x (Vs / Y)2

Short circuit capacity, at transformer secondary

= Vs / (Transformer secondary impedance)2

= Vs / (Z1 x (Vs / Vp) + Z x (Vs / Y)2 2 2

)

Dividing numerator and denominator by Vs2

= 1 / (Z1 / Vp + Z / Y)2

Now Vp / Z1 = X, hence substituting in above equation,2

= (1 / X + Z / Y)1

We multiply both numerator and denominator, by X (Y / Z)

Hence short circuit capacity, at transformer secondary,Ps = X (Y / Z) / (X + Y / Z) -----------(1)

Now we will express X in terms of Ps, Y and Z.

Ps = X (Y / Z) / (X + Y / Z)

Hence, Ps x (X + Y / Z) = XY / Z

Ps x X - XY / Z = - Ps Y / Z

X( Ps – Y / Z) = -PsY / Z

Hence, X = Ps Y / Z / (Y / Z – Ps)---------(2)

We know Y and Z. Hence if we know Ps, then we can find out X.

X can also be expressed in terms of Pt, transformer shortcircuit capacity, as follows:

From (2), X = Ps Y / Z / (Y / Z-Ps)

Y/Z = (Vs / Z2 ) / Z2

= (Vs /( Z x Zs) / Z2

= Pt , as Vs / Zs = Pt, transformer short circuit capacity2

Hence Y / Z = Pt -----------(3)

Hence, X = ---------(4)Pt Ps

Pt – Ps

We can prove this in another way: From figure-1,

Short circuit impedance on transformer secondary side,

Zsc = Zs + Z1(Vs / Vp )2 2

Hence Z1 = (Vp / Vs ) (Zsc - Zs)2 2

Vp / Z1 = Vp x Vs / (Vp ) (Zsc - Zs)2 2 2 2

=Vs / (Zsc – Zs)2

Dividing both numerator and denominator by Vs2

= 1 / (Zsc - Zs) / Vs2

= 1/ (Zsc / Vs – Zs / Vs )2 2

= 1/ (1 / Ps – 1 / Pt)

Hence X = ------- (5)Pt Ps

Pt – Ps

As Vp / Z1 = X, PCC short circuit capacity, in VA; Ps = Vs / Zsc,2 2

Short circuit capacity, at transformer secondary, in VA;

Pt=Vs / Zs, Transformer short circuit capacity .2

Hence once we know Ps, then we can find out X.

From X we can find out Isc = X / Vp

Now how to find out Ps, we will continue in Part-2 of thisField Problem Case Study, in newsletter.December 2018

Z1 = transmission line impedance on primary side oftransformer TR.Zs = transformer secondary winding impedance.Vp = transformer primary voltageZ2 = transformer output impedance as per it's rated capacityZsc = short circuit impedance on transformer secondary sideVs = transformer secondary voltage

Z = transformer per unit impedanceX = PCC short circuit capacity, in VAY = transformer rating, in VAPs = Short circuit capacity, at transformer secondary, in VAPt = Transformer short circuit capacity, in VAPCC = Point of Common Coupling

3≤h<11I /ISC L11≤h<17 17≤h<23 23≤h<35 35≤h≤50 TDD

Maximum harmonic current distortionin percent of IL

Individual harmonic order (odd harmonics) a,b

2.0<20c 1.0 0.75 0.3 0.15 2.5

3.520<50 1.75 1.25 0.5 0.25 4.0

5.050<100 2.25 2.0 0.75 0.35 6.0

6.0100<1000 2.75 2.5 1.0 0.5 7.5

7.5>1000 3.5 3.0 1.25 0.7 10.0

Page 4: OCTOBER 2018 · Indore / Raipur Umesh Bhatia 09589344318 mp@amtechelectronics.com H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Shailesh

DOC. NO. CS-270TITLE: ENERGY SAVING IN PUMP

Payback Period Approximately = 7-9 Months

Industry : Paper

Application : umpP

Motor rating : AC Induction Motor, 3 Phase-

75kW :

415V :olt

7014RPM :

50Hz :

130A :mp

Previous system : Motor was running on tar delta starter.s

Problem observed : 1) High maintenance cost.

.2) Energy losses due to flow control by valve

Present system : 5 kW7 AXPERT-EAZY Variable Frequency Drive used.

kW (Consumption) Valve Position

Previous system

(Without drive) : 71 3kW 9 % Open

Present system

(With drive ) : 4 kW 100 % Open6

System block diagram:

Merits of new system : 1. Easy & Smooth Operation.

2. Energy Saving due to flow control by VFD.

Economical analysis :

�Energy consumption without VFD - P1 = kW71

�Energy consumption with VFD - P2 = kW64

�Energy aving er ay ((P - P2) 24) = Unitss p d 1 x 168

�Saving er ay @ Rs. 4/- Unit = Rs. /-p d 672

�Saving er ear (Approx. 300 Days) = Rs. /-p y 2,01,600

75 kW, 3-PHASEINDUCTION MOTOR

AXPERT-EAZY

3-PHASE,

415 V,

AC SUPPLY

75 kW

PUMP

Page 5: OCTOBER 2018 · Indore / Raipur Umesh Bhatia 09589344318 mp@amtechelectronics.com H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Shailesh

FROM AMTECH POWER

5

CUSTOMER’S VOICE

Page 6: OCTOBER 2018 · Indore / Raipur Umesh Bhatia 09589344318 mp@amtechelectronics.com H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Shailesh

6

PRODUCT OVERVIEW

“Amtech - Your Trusted Partner for Technology and Service”

Energy and Cost Reduction

Enhancing Production Efficiencyand Profitability to The Next Level

Even and Highest Product Quality

Optimizing use of Resources

Maximum Up Time

Wish to get more...

...Use NextGen Solutions

� Smart Drives

� Optimized Processes

� Energy Management

� Integrated Solutions

� Smart Plant Monitoring andControlling

� All data available-Anywhere….Anytime

� Predictive Maintenance Schedule

� Intralogistic Solutions

� Asset Management

� Tailored Service Solutions

With NextGen you get,

Next Generation Technology

Integrated Automation, Drives &Power Quality

Unrivalled Expertise

Wide Experience

Unmatched Customer Support

Take the full Advantage of Amtech’s,

With Our ,NextGen TechnologyGain Total Control of Your Pulp & Paper Mill

Page 7: OCTOBER 2018 · Indore / Raipur Umesh Bhatia 09589344318 mp@amtechelectronics.com H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Shailesh

Name: Designation: E-mail address: Contact Number:

- Whether you will like to receive hard copy or soft copy of our newsletter?

- Your feedback about our newsletter, as mentioned in our newsletter

- Similar details about any of your colleagues, who will like to receive our newsletter

YOU QUESTION, WE ANSWER

Question:

Why the efficiency of an equipment drops when it is not loaded up to its rated capacity?

Any equipment has two types of losses: Fixed losses and variable losses. Fixed losses are same whether theequipment is giving output as per rated capacity or it is loaded partially and its output is a fraction of its ratedcapacity. Variable losses vary in proportion to the loading of the system. For example in Variable FrequencyDrive the power consumed by cooling fan is a fixed loss, whereas the conduction loss in IGBTs is a variable loss.At partial loads the losses are relatively large in relation to the output delivered as compared with those when theoutput is at its rated capacity.

This is clear from the following calculation. If the fixed losses in the system are 5% of its rated capacity and thevariable losses are 0.03% per percent of output delivered, then its efficiency at rated output:

OutputEfficiency (%) = ---------------------

Output + Losses100

= ------------------------ x 100100 + 5 + 0.03 x 100( )

= 92.6%

50Efficiency at 50% output = ----------------------

50 + 5 + 0.03 x 50( )= 88.5%

Page 8: OCTOBER 2018 · Indore / Raipur Umesh Bhatia 09589344318 mp@amtechelectronics.com H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Shailesh

Gandhinagar

Atlanta

GandhinagarAhmedabad

Mumbai

Surat

MuzaffarnagarDelhi(Gurgaon)

Vadodara

Indore

Jamnagar

Udaipur

Kolkata

Nagpur

Pune

Hyderabad

Vapi Raipur

Bhopal

Jamshedpur

JaipurLucknow

Vizag

Bangalore

Chennai

Belgaum

PondicherryTrichy

AurangabadNasik

Chandigarh

Veraval

M. D. Kamath

Paresh Patel

Regional Offices

Contact Person Phone No. (O) Mobile No. E-mail

022-28846083Vrajesh Yadav 09819900501

09108051977

09825042458

[email protected]

[email protected]

[email protected]

Mumbai

Bangalore

Chennai

Delhi

T. S. Sridhar 09840618533 09940229955

.

[email protected]

Umesh Bhatia 09589344318Indore / Raipur [email protected]

H.O. and Service Center

Contact Person Phone No. (O) Mobile No. E-mail

Shailesh Patel 09879208780H.O. Gandhinagar [email protected]

Rajesh Moradiya 09909973780Amtech Service CenterGandhinagar

[email protected]

G. Sateesh Kumar 09573900222Hyderabad [email protected]

Kaushik C. 09932820680Kolkata [email protected]

09825042458

09589344318

09573900222

09932820680

09108051977

Pankaj Gulati 09888748620Chandigarh [email protected]