nr. mts may 2006 innovations 2006 hmi innovations

96
‹Nr.› MTS May 2006 MTS May 2006 Innovations 2006 HMI innovations

Upload: adrian-blackburn

Post on 26-Mar-2015

223 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Nr. MTS May 2006 Innovations 2006 HMI innovations

‹Nr.›

MTS May 2006MTS May 2006

Innovations 2006

HMI innovations

Page 2: Nr. MTS May 2006 Innovations 2006 HMI innovations

‹Nr.›

MTS May 2006

Innovations 2006

SBU 1 Industrial enclosures

Page 3: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 3

Accessories

P. 8

Two-handed operating consoles

• Maximum safety categories are met

• Two safety buttons for each hand

• Thus, hands are on the safety button at all times

• No additional cover is required

Page 4: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 4

Plastic enclosures KS

• P. 15

• Colour changed to RAL 7035

• The colour of accessories has also changed

Page 5: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 5

CM accessories

P. 18

• CM gland plates• Optimised dimensions

• "Old" dimensions did not have the "best fit“

• CM and TS cable entry plate• "Only buy what you really need"

• Packs of 1

Page 6: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 6

CM accessories

P. 21• CM folding lever handle

• Prepared for padlocks• For KESO / KABA• For ASSA

• CM mounting plate slide block• Similar function as the one for TS8• May be reused several times "as a tool"

• CM door stay• Installation without drilling• Spring-mounted• Simply snap into position / snap out

Page 7: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 7

CM accessories

P. 23

• CM rain canopy / vented roof plate• Reliable protection for outdoor siting

• Water runs off to the rear

• Mounting via the existing holes (eyebolts)

• At the front, with integrated ventilation holes at the top

• May also be used when the enclosure is twisted

• Ventilation holes

Page 8: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 8

CM accessories

P. 23

• CM divider kits• For swing frame, large

• With and without trim panel

• For enclosure width mm: 600 and 800 mm

• For swing frame, large with trim panel, the 180° hinge may be used

Page 9: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 9

Comfort Panel

P. 24-34

• New panel / installation depth 113 mm

• Off the shelf:• Operating housing 19" x 7 U x 113 mm

• Keyboard housing 19“ x 3.5 U x 113 mm

• Keyboard housing 19“ x 4 U x 113 mm

• Accessories• USB extension

• Protection category IP 66 / 67

Page 10: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 10

Quickline panelP. 37

• Cut-out for commercially available Siemens panels

• Cost-efficient solution

• In order to open the door, release the hinge pins

• Interior installation with mounting bracket CP 6205.100

Page 11: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 11Compact Panel TFT holder

Surfaces

Niches

AccessoriesP. 39

• Pedestal, height-adjustable• Swivel area max. 180°

• Adjustment range 200 mm

• With integral gas pressurised spring for pressure relief during height adjustment

• Assembly:

• Rear: attachment using cage nuts

• Front: via mounting bracket (accessories).

Page 12: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 12

Accessories

P. 40

Support arm, height adjustable, compact

• For panels and TFTs with 2.5 – 8.5 kg• with VESA 75 cut-out at the top

• Bottom desk clamp for worktops (up to 75 mm thick)

• Adjustment options:• bottom, swivel and tilting

• top, vertically hinged and tilting

• Adaptor for VESA 100 as accessory

Page 13: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 13

Accessories

P. 46

Housing coupling

• Command panels from an installation depth of 150 mm and IW worktops

• Variant for support arm / pedestal

• 350° rotation range may be locked via clamping levers

Page 14: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 14

Industrial workstations

P. 49

IW logistic point

• Complete solution for accommodating:• PC

• Printer

• Monitor

• Supply includes:

Page 15: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 15

Industrial workstations

P. 49

IW logistic point printer cabinet 600 x 900 x 600 mm

• For accommodating • Commercially available printers and desktop PCs

• Designer door prepared for mounting installation modules

• Component shelf, pull-out

P. 49

Paper removal flap• Easy access through integral glazed door

• Installation module with custom-made cut-out as special order, e.g. for label printers

Page 16: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 16

Industrial workstations

P. 54IW stainless steel operating station• For use in

• Food industry• Pharmacy• Petro-chemistry

P. 55• Stainless steel enclosure for tower PC

• W x H x D: 760 x 760 x 300 mm• Roof with cut-out for:

• CP-S support arm• Keyboard cable• Worktop

Page 17: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 17

Accessories

P. 55

• Worktop, stainless steel

• WHD: 900 x 38 x 600 mm

• Laminated on both sides with cut-out for CP-S support arm

• Prepared for stainless steel keyboard or solid

P. 55

• Cross member, stainless steel

• To increase stability, the cross member protrudes 120 mm above and behind

Page 18: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 18

FP housings / enclosures

Available from 2007 on!!!

The regulations are being changed!!!

FP = Fire Protected

Fire-protected housings and enclosures

• Secure escape and rescue paths

• Maintaining the function of:• Elevators

• Emergency power supply

• Extinguishing water

• E.g. public institutions, airports, hospitals, schools, museums, libraries...

Page 19: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 19

FP housings / enclosures

P. 56 All dimensions without lining!!!• FP-TS8 (W x H x D):

• 800 x 2000 x 600 mm• 800 x 2000 x 500 mm• 800 x 1800 x 400 mm

• FP-CM (W x H x D):• 800 x 1000 x 300 mm• 800 x 1200 x 400 mm

• FP-AE (W x H x D): • 600 x 600 x 210 mm

• Other sizes available on request!

Page 20: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 20

FP housings / enclosures

P. 56

FP-PL terminal box with function retention

• Function retention: E 30/ E 60/ E 90

• Protection category: IP 54

• 100 x 100 x 50 mm and

• 115 x 115 x 66 mm

FP – KL

• Function retention: E 30

• Protection category: IP 66

• 115 x 115 x 93 mm with and without fused junction

Page 21: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 21

Stainless steel keyboard housing

P. 51

• 4 dimensions for 1 to 4 command and signalling units 22.5 mm

Page 22: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 22

AE enclosure

P. 52

Four new dimensions for:• AE stainless steel

• Stainless steel 1.4301 (V2A)

Stainless steel 1.4404 (V2A)• Now 5 dimensions available off the shelf

Accessories:

• Cam lock changed for 1.4404

• New wall bracket in stainless steel

Page 23: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 23

AE enclosure

P. 53

AE IP 69K stainless steel

• Same dimensions as stainless steel

• 10° roof tilt prevents liquids from accumulating on the roof

• Silicone seal• Temperature-resistant: -60°C to +180°C

Page 24: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 24

Stainless steel enclosures

Silicone seal for stainless steel enclosures

• Protects better against aggressive cleaning agents and disinfectants

• Seal absorbs almost no water

• Temperature-resistance: -60°C to +180°C

• Also available as special for:• AE stainless steel, single-door • BG stainless steel• KL stainless steel

Page 25: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 25

TS 8

Also available in WxHxD:

• 600 x 1200 x 500 mm

• 800 x 1200 x 500 mm

• 1200 x 1200 x 500 mm

• Suitable side panels as accessories

TS 8 stainless steel: brushed finish changed from 240 to 400 grain:• Enclosures

• Side panels

• Base/plinth components, front and rear

• Baying cover, top

Page 26: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 26

Accessories

P. 178

Pressure relief valve

• Protection category IP 66, 68, 69K

• Reduces the formation of condensation

P. 178

Universal key

• With bit adaptor and turning bit:

• Torx 25

• Recessed head (Ph 2)

Page 27: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 27

Accessories

P. 183• Support rail 65 x 42 mm, unslotted for

enclosure width /depth 400, 500, 600 and 800 mm

P. 183• Support rail for heavy-duty components (up

to 5,000 N / rail)• Suitable for 600 and 800 mm wide

enclosures

P. 182• Attachment for TS punched section with

mounting flange, 17 x 73 mm• when the screw-joint cannot be accessed

Page 28: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 28

Accessories

P. 50

• TS 180° for dynamic loads• Heavy, dynamic loads

• Heavy equipment installed on the door (up to 900 N)

P. 180

• Protective beam and holder• Alternative to a door in a switch room

• Prevents objects from falling into the open enclosure frame

Page 29: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 29

Accessories

P. 179

• Sealing frame for through-panel mounting in rear or side panels

• To suit enclosure widths of 600 mm and above

• In depths of 75 and 100 mm

• Mounting plate in a set forward position

• Protection category IP 54 subject to correct mounting

Page 30: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 30

Accessories

P. 181

Wiring plan pocket

• Sheet steel for TS, CM, ES, PC

• Depth 35 mm

• Plastic, self-adhesive

• Knockouts for optional screw joints

Page 31: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 31

Accessories

P. 190

Cable conduit

• Two sizes: SW 29 / 50• Connected straight or in a 90° angle

• Holder for correct laying

Page 32: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 32

Accessories

P. 195

Compact light

• Multifunctional fastening on both sides• Magnet, clip, screws or combinations thereof

• May be positioned flexibly

• Saves power whilst producing more light• 8 watts compare with 14 watts standard/courtesy lights

• 18 watts brighter than 14 watts standard/courtesy lights

• Integral connection cable, 3 m

• Pluggable door-operated switch as accessory

Page 33: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 33

Accessories

P. 186

Socket strip

• With three sockets, overvoltage protection and interference filter

• Socket inserts twisted by 45°

• Connection socket for front power supply

Page 34: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 34

Accessories

Flyer

Connector gland

• Sealing frame for connector cut-outs 16/24-pole for 8/10 cables

• No dismantling required when individual cables/leads must be installed/dismantled

• Seals are fastened safely to the cable

• Incl. strain relief

Page 35: Nr. MTS May 2006 Innovations 2006 HMI innovations

‹Nr.›

MTS May 2006

Innovations 2006

SBU 4 Power distribution

Page 36: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 36

RiLine60

• 60 mm busbar system

• Flat bar system with integral cross section adaptation: Now also available with base tray technology

• Top-mounting PLS systems: easier to assemble

• Connection adaptor with impressive connection system and a great number of versions

Page 37: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 37

RiLine60

• Type-tested to EN60439-1

• NEW: GL-approved

• System includes: approx. 130 articles

• Universal CB adaptor up to 630 A

• Innovative component adaptor system with support frame connector

• Protection category IP2x

Page 38: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 38

RiLine60

• Support frame with push-in trim• Important accessory for replacement

assemblies for RiLine60 Premium adaptors

• Incl. support rail and push-in trim

• New adaptor versions• OM adaptor, 45 mm wide, with AWG10

• OM adaptor, 75mm wide, with AWG6

• Connection angle for CB adaptors• Designed to suit 250 A CB adaptors

• Designed to suit 630 A CB adaptors

Page 39: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 39

RiLine60 UL design

• New busbar holder with greater creepage distances and clearance• Base tray is a must-have

• Short circuit data are similar to the IEC design

• Top-mounting components are identical with the IEC line• OM / OT adaptors with AWG leads only

• CB adaptor 160 A in specific design

• New connection adaptor for PLS

• Rated data differ sometimes from IEC

• To be approved by June 2006

Page 40: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 40

298 mm250 mm (250)NH3

298 mm210 mm (210)NH2

298mm184mm (186)NH1

194mm106 mm (115)NH00

HeightWidth (before)Size

RiLine60

• RiLine NH – the new generation of isolators

• Consistent design of all sizesfrom NH00 to NH3

• With tried-and-trusted clamping screw technique

• Simple reversal of the cable outlet at thetop or bottom by rotating the mounting hooks

• Perfectly integrated into the RiLine60 contact hazard concept: IP 2X

• Safe operation, thanks to contact hazard protection

• Lid may be locked

• Available from: 11/06 (NH00+1) and 01/07 (NH2+3)

Page 41: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 41

Maxi PLS

• Corner connector for Maxi-PLS • For 90° connection for busbar systems in

the roof area

• Available for 1600A / 2000A / 3200A

• Packaging: Packs of 1 set

• Corner bracket for Maxi-PLS• For 90° connection for busbar systems in

the rear area

• Versatile

• Available for 1600A / 2000A / 3200A

• Packaging: Packs of 1 set for each busbar

Page 42: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 42

Maxi PLS

Maxi PLS–vertical coupling sets 1600 A

• Vertical coupling sets for Maxi-PLS 1600 A for busbar systems in the roof and rear area

• Rittal Maxi-PLS compact infeed• Flexible cable connection bar system,

whatever the enclosure width

• Several adjacent infeeds in one enclosure

• Direct mounting on the punched section without mounting flange or on the mounting plate

• For Maxi-PLS 1600 A / 2000 A busbars

Page 43: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 43

ISV

• Roof plate for cable entry gland • Roof plate with gland apertures

• In exchange for the standard TS8 roof plate

• Suitable for enclosures with Widths: 600, 850 and 1100 mmDepths: 400 and 600mm

• Solid cable entry gland.• For concealing unused openings

• Inexpensive alternative to the existing gland plates

Page 44: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 44

Power Engineering V2.0

• New (compared to V1.0)• Corner field• 2200 mm high enclosures• Parts lists can be exported directly into Excel• Automatic text configuration for special

connection kits• Flexible user tool "My Accessories"

• Optimised • PE and neutral conductor configuration• More accessories can be configured (divider

panels, covers, etc.)• Maxi-PLS and ISV can be configured as

separate enclosures in a project.

Page 45: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 45

Maxi-PLS

• Prototype system with internal division, design 4a • with form subdivision Form 2-4 according

to IEC 2 60439-1

• For rated currents up to 1600 A

• May be used as power distribution system (PCC) and control system (MCC).

• Modular interior installations with system components

• Flat bars or PLS bars may be selected from the RiLine60 program

• Available from October 2006

Page 46: Nr. MTS May 2006 Innovations 2006 HMI innovations

‹Nr.›

MTS May 2006

Innovations 2006

SBU 3 System climate control

Page 47: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 47

TopTherm & RiNano

PLUS • RiNano-coated condenser in all cooling units

• Electronic condensate evaporation integrated into all roof-mounted and wall-mounted units with cooling outputs of 1000 watts or greater

Page 48: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 48

Enclosure cooling during the production of disc brakes

Application: Audi Ingolstadt

Page 49: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 49

RiNano cooling unit

• SK 3305.100 / 1500 watts• Has been operated since June 2005

• No filter mat

• Has not been serviced so far

• Extreme condition:• Dust

• High ambient temperatures

• High power loss inside the enclosure

Page 50: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 50

Enclosure cooling during the production of disc brakesApplication: Audi Ingolstadt

• Existing units without RiNano have been used for 5 to 6 years

• The cooling units must serviced regularly to ensure that they operate continuously.

• Filter mats must be replaced every week!

• The picture shows a filter mat after 5 days!

Page 51: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 51

TopTherm & RiNano

Benefits:

• Clean heat exchangers

• Longer maintenance intervals

• No power drop

• Higher energy efficiency

• Easier to clean

• No filter mats (dry dust)

• Longer downtimes (metal filters for oil-bearing air)

Page 52: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 52

Condensate management

• Integrated condensate management• Requirements from the automobile industry

• Risk of accidents Puddles

• Specified by the US automotive industry

• RTT cooling unit series with integrated condensate evaporation• For all roof-mounted and wall-mounted units

from 1000 watts on

Page 53: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 53

Condensate management

Page 54: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 54

Air/water heat exchangers

New series

• 500 to 5000 watts

• 230 V, 115 V and 400 V, 2~,

• Optionally with basic or comfort controller

• Slimline design

• Comes with all water-carrying parts in V4A -1.4571

Page 55: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 55

Mounting cut-outs suitable for “mounting” on RTT wall-mounting cooling units

Air/water heat exchangers

Page 56: Nr. MTS May 2006 Innovations 2006 HMI innovations

‹Nr.›

MTS May 2006

Innovations 2006

SBU 3

Recooling systems

Page 57: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 57

Recooling systems

• Wall-mounted, 4,000 watts

• RiNano-coated as standard

• Controlled via Microcontroller Box (MCB) • Individual fault messages are processed by the

display and the diagnosis software

Page 58: Nr. MTS May 2006 Innovations 2006 HMI innovations

‹Nr.›

MTS May 2006

Innovations 2006

SBU 6

Outdoor & fuel cells

Page 59: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 60

Toptec CR

• 4 dimension variants• W: 600/800 x H:1,200/1,600 x D: 600 mm

• Welded vertical section with roof and bottom (base/plinth integrated) made of V2A stainless steel

• Twin-walled doors and side panels made of zinc-plated sheet steel

• Rain canopy made of aluminium

• Fully spray-finished in RAL 7035

Page 60: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 61

Toptec CR

• Simple baying, since there is no side roof projection

• Toptec cooling modules may be used

• Lifting eyebolts are not included in the supply. Rain canopy must be dismantled if the unit is transported by crane

• Double side panel at the inside which means that the outer TS8 frame level can only be accessed with difficulty

Page 61: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 62

• Door stay • Made of round steel, opening range: 90°,

115° or 130°

• More robust than the old version

• Door handle • Swing lever with direct access to the semi-

cylinder

Toptec CR

Page 62: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 63

• Toptec concrete base/plinth• 600 / 800 mm wide

• 600 mm deep

• Depth stay for Toptec CR• For W: 800 mm D: 600 mm

• Mounted on the inner level

• Assembly kit• In the enclosure depth

• For attaching mounting plates / swing frames

Toptec CR accessories

Page 63: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 64

Small applications

up to 250 wattsOutdoor UPS

From 3 to 15 kW

Indoor UPS

From 10 to 200 kW

CatalogueProject solution Concept

Fuel cell technology

• 3 different applications and output categories

Page 64: Nr. MTS May 2006 Innovations 2006 HMI innovations

‹Nr.›

MTS May 2006

Innovations 2006

SBU 5

Rittal Smart Package, racks and accessories

Page 65: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 66

Rittal Smart Package

• Pre-configured TS8 server racks • 800 mm wide, 42 U, 1000 mm deep

• In different designs for small and medium-sized companies:• Integrated PSM busbar

• 2 kVA or 3 kVA UPS installed

• Different climate control concepts:

• Slotted doors

• Roof-mounted fan

• Wall-mounted cooling unit on the rear door

• With CMC-TC installed in some cases

Page 66: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 67

TS8/HPC network and server enclosures

Server enclosures, 1200 mm deep,

• 2000 + 2200 mm high

• RAL 7035 / 9005

• Standard mounting angles

HPC (High Power Cooling) enclosures, 1200 mm deep,

• WxH 600 / 800 x 2000 mm

• To be combined with LCP/LCP

• Protection category up to IP 55

• 482.6 mm (19") mounting frame

• Load capacity up to 1000 kg max.

Page 67: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 68

Accessories

• DK-TS side panels• May be screw-fastened / plugged

• 2000 / 2200 high

• TS roof plate• for cable entry, two-piece

• 600 / 800 mm wide

• Interior installation:• TS punched section with mounting

flange 17 x 73 mm, outer level (notched!)

• DK C rails

• TS cable clamp rails for TS and 482.6 mm (19") mounting frames

Page 68: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 69

Accessories

• DK stabiliser, pull-out• Load capacity up to 150 kg

• System supports for cable routes• For 800 - 1200 mm deep enclosures

• TS base/plinth in RAL 9005 and 7035• More dimensions

• TS punched section with mounting flange 17 x 73 mm• With slots• for 900, 1000, 1200 mm width /

depth

Page 69: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 70

Accessories

TS partition

• HxD 2000/2200 x 1000/1200 mm

• For sliding in and partitioning retrospectively, especially in conjunction with climate control components in enclosures suites

• With concealed cut-outs in all corners for routing cables and leads between the enclosures

Page 70: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 71

Accessories

TS IT glazed door• Aluminium frame section in a new

design• Integrated hinges• 180° opening even when bayed• New, flat handle system• It is possible to conceal the cable

routing to the handle and to the sensorics

• Dimensions• Width: 600 / 800 mm• Height: 800 - 2,200 mm

• Standard glazed door in IT Catalogue 2006!

Page 71: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 72

Accessories

TS infill panel

• for network enclosure, 800 mm wide

• Installation height: 33, 38, 42, 47 U

• Large cable storing space

• May be combined with large shunting ring

• May be fastened on the vertical frame section, at the inside

• Depth-variable, on the punched section, inside

• Hinged version

• Open/closed action point

Page 72: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 73

Accessories

• Cable anchor (black)• Size of the shunting ring 1 U / 4 U

• Cranked for mounting angles and mounting frames

• Especially for mounting on all panels such as punched sections, cable channels, frames

• Distributor ring (chrome-plated)• For cascaded cable routing

• to mounting angles and mounting frames

• to all panels

Page 73: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 74

Accessories

• Slide rail, 740 mm, stationary installation• Matches HP standard dimensions, 740

mm distance between the levels

• 100 kg static load

• Depth-variable slide rail, 1 U• 80 kg static load

• 390-600 / 590-930 mm long

• Particularly slimline design

• Potential equalisation point• Star point for earthing bolt

• Contacts up to 5 earthing straps with 6.3 mm flat-pin connectors

Page 74: Nr. MTS May 2006 Innovations 2006 HMI innovations

‹Nr.›

MTS May 2006

Innovations 2006

SBU 5 PSM and UPS

(uninterrupted power supply)

Page 75: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 76

PSM Plus busbar and modules

• Power System Module PSM Plus with four infeeds

• 3-phase / redundant design

• Different module versions, sometimes with double infeed

• Can distribute twice as much power as the latest PSM, i.e. 192 A/busbar

Page 76: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 77

PSM system

• PSM with 3-phase voltage monitoring• Displays and monitors the connection current and

the active power / phase• For 2000 mm high enclosures with 6 slots• Remote monitoring via CMC-TC

• PSM accessories• Cable lock: connection cable• For all modules with IEC320 C13 jack

• PSM light module• For use as a portable lamp with a NiMH battery• 3 hours illumination time and magnetic

attachment

Page 77: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 78

Static transfer switch (STS)

Available upon request:

• 482.6 mm (19") design, 2 U

• Switches automatically between two infeeds

• Increases availability through redundancy

• Single-phase switching load: 16 A

• Networking capability (SNMP)

• May be applied in the IT business• Server racks

• Network racks

• Data centres

• Networks in general

Page 78: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 79

UPS PMC 200, 2nd generation

• UPS modules 10/20 kW• 600 mm wide racks

• UPS modules 30/40 kW• 800 mm wide racks

• Improved efficiency (96%)

• Redundant n+1 system architecture in modules and batteries

• See IT News 2006, p. 20-26

Page 79: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 80

UPS PMC 200, 2nd generation

• Benefits• Flexible, simple expansion with the

system operational• The fact that modules can be

replaced easily make servicing fast and cost-effective

• May be applied in the IT business• Data centres, IP telephony• Networks in general

• May be applied in the IE business• Mechanical engineering in general• Automotive

Page 80: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 81

N+1 redundancy in an example with 40 kW

1+1, 40kW modules 2 + 1, 20kW modules 4 + 1, 10kW modules

UPS PMC 200, 2nd generation

Page 81: Nr. MTS May 2006 Innovations 2006 HMI innovations

‹Nr.›

MTS May 2006

Innovations 2006

SBU 5 Security / monitoring

Page 82: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 83

CMC-TC

• New CMC-TC software functions• New web design

• Network Time Protocol NTP

• SSL and SSH

• DHCP

• Applications• Large network systems

• RimatriX5 data centre

Customer benefits: More comfort, more security, more transparency

Page 83: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 84

CMC-TC accessories

• Display Unit II • Graphical, illuminated LED display

• Displays temperature, humidity, access, climate control units, LCP, ActivePSM and PCU

• The network interface of PU II may be set via keys

• Power supply via PU II

• Applications• Applications without network

• Informs locally

Page 84: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 85

CMC-TC accessories

Redundant power supply for CMC-TC

• Two voltage inputs, one voltage output

• Switches without interruption

• With power pack for 90-230 VAC or 48VDC

• For 24 V DC

• Alarm interface with the I/O unit

• Optical alarm display

7200.210

7200

.210

7320.425

7320.425

24 V DC

AlarmU1 / U2

U1 U2

Page 85: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 86

CMC-TC accessories

• Voltage monitor with 16 A C19/C20 switched output• Switches high currents 16 A

• In de-energised state: ON

• Switches high-performance IT/server components up to 16 A

• 1 U fixture for CMC-TC sensors• Accommodates up to 22 CMC-TC

sensors

• Cable clamping

Page 86: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 87

CMC-TC accessories

• Comfort handle for TS8 Legic (WO)• Legic transponder technology

• Receiver aerial in the handle

• Acoustic/optical signal in the handle

• Electronics in the CMC-TC housing• Carrier frequency: 13.56 MHz

• Biometric access system (WO)• Thermal sensor

• Compatible with the CMC access system

• Up to 99 users / 10 fingers for each user

• May be used outdoors

Page 87: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 88

SSC Rittal KVM technology

• SSC compact 8 • Inexpensive KVM switch based

on standard PC interfaces, 1 U• Compatible with VGA & PS/2• Compatible with other servers

via adaptors• May be combined with SSC

multi (without OSD transfer)

• SSC compact 32 Cat• 32 server ports in 1 U• For SSC: converters for PS/2,

USB & SUN-USB• May be cascaded to up to three

more SSCs; max. 125 servers on one user (with OSD transfer)

Page 88: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 89

SSC Rittal KVM technology

SSC compact

• Password-protected OSD menu for configuration and server selection

• Selection may also be made via hotkeys

• Convenient function such as autoscan and autoskip

• May be installed in 482.6 mm (19") levels

• Integral wide-range power pack, IEC 320 connection (EN 60320, C14, 100 V-240 V AC 50/60 Hz)

Page 89: Nr. MTS May 2006 Innovations 2006 HMI innovations

‹Nr.›

MTS May 2006

Innovations 2006

Cooling

Page 90: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 91

LCP Liquid Cooling Package

• LCP Standard

• Additional dimensions• WxHxD: 300 x 2000 x 1,200 mm

• Connector system replaces the hose clamps

• Solid base tray designed as condensate tray

• Condensate is drained off either via return to to the outside

• Main connection is at the rear or bottom

Page 91: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 92

LCP Liquid Cooling Package

LCP Extend

• Extends existing room air-conditioning

• Cooling output about 10 kW per rack

• May be retrofitted on rear doors of vented enclosures

• Bayable, door opening max. 90°

• Water connection from below or above

• May be connected to CMC / RiWatchIT

• Compatible with Rittal IT cooling unit line

Page 92: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 93

LCP Liquid Cooling Package

LCP +

• Same as standard LCP, but with higher output

• Cooling output 30 kW

• WxHxD: 300 x 2000 x 1,200 mm

• Easy servicing for important components(e.g. fans can be replaced without tools)

• Active condensate management

• Cooling even with the server rack doors open

• May be connected to CMC / RiWatchIT

Page 93: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 94

LCP accessories

• Vertical shielding• May be used HPC server racks

• Prevents "air short circuits"

• Horizontal shielding

• Air inlet/outlet of the cover plate• May be used in the LCP rack

• Top-mounted cover for LCP (200 mm)• May be adapted to 2200 high server racks

Page 94: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 95

LCP accessories

• LCP ventilation for maintenance works and retrofitting

• Connection hose

• Quick-release couplings for configuring water connections

Page 95: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 96

IT recooling systems

• Requirements specific to Rimatrix

• Pressure-sealed systems

• Field of application: -20°C to +45°C (outdoor siting)

• May be connected to CMC and collective fault signal

• Increased safety through twin pump and redundant cooling circuits

Page 96: Nr. MTS May 2006 Innovations 2006 HMI innovations

Thema oder Anlass des Vortrags Autor / Abteilung / Datum 97

4 8 10 12 20 24 30 36 40 48 50 60 70 80 84 90 100 110 120 130 140 150SK 3301.900

SK 3301.901

SK 3301.902

SK 3301.905

SK 3301.910

SK 3301.912

SK 3301.915

SK 3301.920

SK 3301.925

SK 3301.930

Recooling systems Power range of RiMatrix recooling systems in kW

Project business:

Example AWE

Cooling output 4x280 kW

Example

Recooling systems SK 3300.902Cooling output12,000 wattsat Tw = 15°C and Ta = 32°C

IT recooling systems