npv - xylem.com

28
NPV VERTICALLY IMMERSED ALL STAINLESS STEEL END SUCTION PUMPS BOMBAS NPV DE ASPIRACIÓN AXIAL, TODAS DE ACERO INOXIDABLE, SUMERGIDAS VERTICALMENTE TECHNICAL BROCHURE BNPV R4

Upload: others

Post on 06-Feb-2022

22 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NPV - xylem.com

NPVVERTICALLY IMMERSED ALL STAINLESS STEEL END SUCTION PUMPSBOMBAS NPV DE ASPIRACIÓN AXIAL, TODAS DE ACERO INOXIDABLE, SUMERGIDAS VERTICALMENTE

TECHNICAL BROCHUREBNPV R4

Page 2: NPV - xylem.com

PAGE 2

Commercial WaterGoulds Water Technology

Optional: Hardened Shaft (Ceramic)

Shaft, Bearing and Elastomer OptionsStandard is Option 1Opciones de eje, cojinete y elastómeroOpción 1 es estándar

Impeller Option Code... No Adder RequiredFor optional impeller diameters modify catalog order no. with impeller code listed. Select optional impeller diameter from pump performance curve.Código del Impulsor Opcional... No necesita sumadorPara impulsores con diámetros opcionales modificar el número de orden del catálogo con el código del impulser anotado. Escoger el impulsor con diámetro opcional de la curva de rendimiento de la bomba.

Driver, Conductor01 = 1 PH, ODP 07 = 3 PH, XP02 = 3 PH, ODP 08 = 3 PH, XP 575V03 = 3 PH, ODP 575V 10 = 1 PH, XP04 = 1 PH, TEFC 15 = 3 PH, WD05 = 3 PH, TEFC 20 = 3PH, WD 575V06 = 3 PH, TEFC 575V E

HP Rating, Potencia en HPC = ½ HP E = 1 HP G = 2 HP J = 5 HPD = ¾ HP F = 1½ HP H = 3 HP K = 7.5 HP

Driver: Hertz/Pole/RPM, Condutor: Hercois/Polos/RPM1 = 60 Hz, 2 pole, 3500 RPM 4 = 50 Hz, 2 pole, 2900 RPM2 = 60 Hz, 4 pole, 1750 RPM 5 = 50 Hz, 4 pole, 1450 RPM3 = 60 Hz, 6 pole, 1150 RPM

Material, MaterialSL = Stainless Steel Closed ImpellerSR = Stainless Steel Open ImpellerSL = Impulsor cerrado, de acero inoxidableSR = Impulsor abierto, de acero inoxidable

Pump Size, Tamãno de la Bomba100 = 1 x 1¼ – 6 150 = 1½ x 2 – 6 125 = 1¼ x 1½ – 6

A FULL RANGE OF NPV PRODUCT FEATURES UNA GAMA TOTAL DE CARACTERÍSTICAS DEL PRODUCTO NPV

Superior Materials of Construction: Complete AISI 300 series stainless steel liquid handling components for corrosion resistance, quality appearance and improved strength.

High Efficiency Impeller: Enclosed impeller with unique floating O-ring design maintains maximum efficiencies over the life of the pump without adjustment.

Casing Features: Stainless steel construction with NPT threaded, centerline connections.

Motors: NEMA standard open drip-proof*, totally enclosed fan cooled* or explosion proof enclosures*. Rugged ball bearing design for continuous duty under all operating conditions.

* Premium efficiency where required by Department of Energy regulations.

Materiales Superiores de Construcción: Componentes completos para manejo de líquidos en acero inoxidable 300 AISI, resistencia a la corrosión, apariencia de calidad, y resistencia mejoradas.

Impulsor de Alta Eficiencia: El impulsor encerrado con un diseño único de anillo en O flotante, mantiene sin ajustes, la eficiencia máxima durante la vida de la bomba.

Características de la Carcasa: Construcción de acero inoxidable con rosca NPT, conexiones centrales.

Motores: Estándar NEMA en cubiertas abiertas a prueba de goteo*, totalmente cerradas y enfriadas con ventilador*, o en cubiertas a prueba de explosión*. Diseño robusto de cojinetes de bolas para trabajo continuo en todas las condiciones de funcionamiento.

* Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

The various versions of the NPV are identified by a product code number on the pump label. This number is also the catalog number for the pump. The meaning of each digit in the product code number is shown at left.

NPV PRODUCT LINE NUMBERING SYSTEM LÍNEA DE PRODUCTO NPV SISTEMA DE NUMERACIÓN

Materials, Materiales Shaft, Bearing, O-rings, Eje Cojinete Anillos en O 1 14" Viton, Viton Viton, Viton 2 14" Carb. graph., Graf. de Carb. Viton, Viton 3 14" EPR EPR 4 14" Carb. graph., Graf. de Carb. EPR 5 24" Viton, Viton Viton, Viton 6 24" Carb. graph., Graf. de Carb. Viton, Viton 7 24" EPR EPR 8 24" Carb. graph., Graf. de Carb. EPR

SR

SL

Example Product Code, Ejemplo Código del Producto

1 SL 2 C 01 A 1 H

Las diferentes versiones de la NPV se identifican con un número de código del producto en la etiqueta de la bomba. Este número es también el número del catálogo para la bomba. El significado de cada dígito en el número de código del producto se muestra a la izquierda.

Option,Opción

* Premium efficient where required by DOE

Impeller Code,

Código delImpulsor

Pump Size, Tamãno de la Bomba

1 x 1¼ – 6 1¼ x 1½ – 6 1½ x 2 – 6

Impeller Diameter (in.)

100SL 100SR 125SL 125SR 150SL 150SRA 6 1/8 5 3/8 6 1/8 5 5/16 5 1/8 5 7/16B 5 ¾ 5 5 15/16 5 1/16 5 5 ¼C 5 3/16 4 5/16 5 ¾ 4 5/8 4 ½ 4 15/16D 4 ¾ 4 5 11/32 4 5/16 4 ½ 4 5/8E 4 7/16 3 ¾ 5 1/16 4 1/16 4 3/8 4 7/16F — 3 ½ 4 7/8 3 ¾ 4 4 3/16G — 3 ¼ 4 5/8 3 7/16 3 5/8 3 ¾H — 3 4 ¼ — — —J — — 4 — — —

Page 3: NPV - xylem.com

PAGE 3

Commercial WaterGoulds Water Technology

NPV PERFORMANCE COVERAGE (60 HZ) COBERTURA DE RENDIMIENTO NPV (60 HZ)

METERSMETROS

FEETPIES

TOTA

L D

YN

AM

IC H

EAD

(CAR

GA

DIN

AMIC

A TO

TAL)

(H)

CAPACITY (CAPACIDAD) (Q)

0

160

140

120

100

80

60

40

20

50

40

30

20

10

00 20 40 60 80 100 120 140 160

0 5 10 15 20 25 30 35

3SL 1750 RPM

1 x 11⁄4-61⁄2-2 HP

3500 RPM1SL

2SL 1750 RPM

1SL1750 RPM

11⁄2 x 2-61-5 HP

3500 RPM3SL

11⁄4 x 11⁄2-63⁄4-5 HP

3500 RPM2SL

U.S. GPM

m3/hr

NOTES: 1. Not recommended for operation beyond printed H-Q

curve.

2. For critical application conditions consult factory.

3. Not all combinations of motor and impeller options are available for every pump model. Please check with G&L on non-cataloged numbers.

NOTAS: 1. No se recomienda para funcionamiento superior al impreso

en la curva H-Q.

2. Para condiciones de aplicaciones críticas consultar con la fábrica.

3. No todas las combinaciones de las opciones de motor e impulsor están disponibles para cada modelo de bomba. Por favor verifique con G&L los números no catalogados.

FEET

CAPACITY (CAPACIDAD) (Q)

METERS

TOTA

L D

YN

AM

IC H

EA

D (C

AR

GA

DIN

AM

ICA

TO

TAL)

(H)

100

0 100 125 150 U.S. GPM175

5 2015 m3/hr

30

10

20

80

60

40

20

025 50 75 200

35

5

120

225 250

3SR3500 RPM

2SR3500 RPM

1SR3500 RPM

1SR1750 RPM 2SR

1750 RPM

3SR1750 RPM

MODEL NPV “SR” PERFORMANCE COVERAGECOBERTURA DE RENDIMIENTO

DEL MODELO NPV “SR”

15

25

10 25 30 35 40 45 50 550

0* Premium efficient where required by DOE

Page 4: NPV - xylem.com

PAGE 4

Commercial WaterGoulds Water Technology

NPV SL/SR MAJOR COMPONENTS: MATERIALS OF CONSTRUCTION COMPONENTES PRINCIPALES NPV SL/SR: MATERIALES DE CONSTRUCCIÓN

23

10

9

8

1212A

11

141315A15B15C

176 7

54

16

DISCHARGEDESCARGA

2 22 (1SR ONLY)(1SR SOLAMENTE)

SUCCIÓN

DISCHARGEDESCARGA

3 1 21 SUCTIONSUCCIÓN

20

1819

SR SL

Page 5: NPV - xylem.com

PAGE 5

Commercial WaterGoulds Water Technology

20 1 Nut, impeller Tuerca, impulsor

Impeller (open), Impulsor (abierto)

Item No., Qty. Description, Materials, Parte No. Cant. Descripción Materiales

Casing, Pump SL; Carcasa, bomba SL

Casing, Pump SR; Carcasa, bomba SR

3 1 Guidevane, Aleta guiadora

4 1 O-ring, Casing; Viton/EPR, Anillo en 0, carcasa Viton/EPR

¼-20 NC-2A x .50 long socket head cap screw, 5 8 Tornillo de casquete de cabeza hueca de ¼-20 NC-2A x, 0,50 de largo

¼-20 NC hex nut, Tuerca hexagonal de ¼-20 NC

AISI 303 SS, 7 1 AISI Acero inoxidable 303

3⁄8-16 NC-2A x 1.0 long hex head bolt, Perno de cabeza hexagonal de 3⁄8-15 NC-2A x 1,0 de largo

Motor mounting plate, Cast iron, Placa de montaje del motor Hierro fundido

10 1 Motor, Motor Electrical, Eléctrico

11 1 Tube, support; Tubo, apoyo

12 1 Shaft, Eje

12A 1 Shaft, Ceramic Coated, Eje

Stainless steel, Acero inoxidable

Nitronic 60 stainless, Nitronic 60, inoxidable

15A 1 Bearing, Cojinete Viton, Viton

Carbon graphite, Grafito de carbono

15C 1 Bearing, Cojinete EPR

1 1

2 1

6 8

8 4 Plated steel, Acero enchapado

AISI 304 SS,AISI Acero inoxidable 304

AISI 316 SS,AISI Acero inoxidable 316

Pump mounting plate,Placa de montaje de la bomba

9 1

AISI 304 SS,AISI Acero inoxidable 304

13 1 Snap ring, Anillo de resorte

14 1 Bushing, Casquillo

15B 1 Bearing, Cojinete

Item No., Qty. Description, Materials, Parte No. Cant. Descripción Materiales

AISI 316 SS, 16 1 AISI Acero inoxidable 316

Impeller (closed), Impulsor (cerrado)

Plug, drain and vent; Tapón, drenaje y ventilación

O-ring, drain and vent plug; 19 2 Anillo en 0, tapón de drenaje y ventilación

300 Series SS, Serie 300, AI

O-ring, impeller; Anillo en 0, impulsor

O-ring, internal casing; Anillo en 0, carcasa interna

23 1 Seal, U-cup; Sello, taza en U Teflon, Teflón

* Not required on 2SL & 3SL.

AISI 316 SS,AISI Acero inoxidable 316 18 2

17 1

Viton/EPRViton/EPR

21 1 Viton, Viton

22* 1 Viton, Viton

Page 6: NPV - xylem.com

PAGE 6

Commercial WaterGoulds Water Technology

NPV PERFORMANCE CURVES – 60 HZ, 3500 RPM CURVAS DE RENDIMIENTO NPV – 60 HZ, 3500 RPM

NPV/100SL 1x1 1/4 -6 3500 rpm ANSI/HI 14.6 - Grade 2B

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5

0 10 20 30 40 Q [Imp gpm]    

Q [l/s]

A

C

46.8

48.1

48.1

46.8

48

47

46

46

45

45

43

43

40

0 3 6 9 12

0

10

20

30

40

50

0

20

40

60

80

100

120

140

160

180Q [m3/h]

H [m]H[

ft]

6 1/8"

B

4 3/4"

4 7/16"

5 3/16"

5 3/4"

D

E

0

1

2

3

4

0

5

10

15

NPSH [m]NP

SH[ft]

AE C

A

B

C

E

0.0

0.5

1.0

1.5

2.0

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0 10 20 30 40 50 60

PP [kW

]

Pp[HP]

Q [US gpm]

D

NPV/10

0SL 1x1 1/4 ‐6_6

0Hz_2_

0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 7: NPV - xylem.com

PAGE 7

Commercial WaterGoulds Water Technology

Ordering Code, Imp. Código de Pedido Dia.

F 37/8"

E 41/4

D 45/8

C 47/8

B 51/16

A 51/4

G 515/16

H 51/2

K 61/8

NPV/125SL 1 1/4 x 1 1/2 - 6 3500 rpm ANSI/HI 14.6 - Grade 2B

0 1 2 3 4 5 6 7 8

0 20 40 60 80 100 Q [Imp gpm]      

Q [l/s]

A

C

E

60.4

64.0

65.0

64.4

63.8

63

63

57

57

544943

J

0 5 10 15 20 25 30

0

10

20

30

40

50

0

20

40

60

80

100

120

140

160

180Q [m3/h]

H [m]H[

ft]

6 1/8"

5 3/4"

5 1/16"

4 5/8"

4"

60

60

G

5 15/16"

B

D

66.0

5 11/32"

F

H

4 1/4"

4 7/8"

0

5

10

15

20

0

10

20

30

40

50

NPSH [m]NP

SH[ft]

A

C

E

G

J

0

1

2

3

4

0

1

2

3

4

5

6

0 20 40 60 80 100 120 140

PP [kW

]Pp[HP]

Q [US gpm]

B

D

F

H

NPV/12

5SL 1

 1/4 x 1 1/2 ‐6

_60H

z_2_

0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 8: NPV - xylem.com

PAGE 8

Commercial WaterGoulds Water Technology

NPV PERFORMANCE CURVES – 60 HZ, 3500 RPM CURVAS DE RENDIMIENTO NPV – 60 HZ, 3500 RPM

NPV/150SL 1 1/2 x 2 - 6 3500 rpm ANSI/HI 14.6 - Grade 2B

0 2 4 6 8 10

0 20 40 60 80 100 120 140Q [Imp gpm]    

Q [l/s]

AB

C

66.8

68.0

66.0

61.8

67

67

61

61

57

57

5145

G

0 5 10 15 20 25 30 35 40

0

20

40

60

80

100

120

0

20

40

60

80

100

120Q [m3/h]

H [m]H[

ft]

5 1/8"

5"

4 3/4"

4 3/8"

E

3 5/8"

65

65

D

F

4 1/2"

4"

0

2

4

6

0

5

10

15

20

25

NPSH [m]NP

SH[ft]

AB

C

E

G

0

1

2

3

4

0

1

2

3

4

5

6

0 20 40 60 80 100 120 140 160 180

PP [kW

]

Pp[HP]

Q [US gpm]

F

D

NPV/15

0SL 1

 1/2 x 2 ‐6

_60H

z_2_

0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 9: NPV - xylem.com

PAGE 9

Commercial WaterGoulds Water Technology

NPV PERFORMANCE CURVES – 60 HZ, 1750 RPMCURVAS DE RENDIMIENTO NPV – 60 HZ, 1750 RPM

NPV/100SL 1x1 1/4-6 1750 rpm ANSI/HI 14.6 - Grade 2B

0.0 0.5 1.0 1.5

0 5 10 15 20 Q [Imp gpm]    

Q [l/s]

A

D

46.7

48.1

47.1

45.3

48

47

46

46

45

45

43

43

40

C

0 1 2 3 4 5 6

0

2

4

6

8

10

12

0

5

10

15

20

25

30

35

40

45Q [m3/h]

H [m]H[

ft]

6 1/8"

B

4 3/4"

4 7/16"

5 3/16"

5 3/4"

FE

4 1/16"

0

1

2

3

4

0

5

10

15

NPSH [m]NP

SH[ft]

AF C

A

B

D

F0.00

0.25

0.00

0.25

0.50

0 5 10 15 20 25 30

PP [kW

]

Pp[HP]

Q [US gpm]

C

E

NPV/10

0SL 1

x1 1/4‐6_6

0Hz_4_

0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 10: NPV - xylem.com

PAGE 10

Commercial WaterGoulds Water Technology

NPV/125SL 1 1/4 x 1 1/2 - 6 1750 rpm ANSI/HI 14.6 - Grade 2B

0 1 2 3 4 5

0 10 20 30 40 50 60Q [Imp gpm]    

Q [l/s]

AC

E

56.8

60.7

62.2

60.7

63.6

60

60

53

53

504640

J

0 2 4 6 8 10 12 14 16 18

0

5

10

15

20

25

30

35

40

45

0

5

10

15

20

25

30

35

40

45Q [m3/h]

H [m]H[

ft]

6 1/8"

5 15/16"

5 3/4"

5 11/32"

5 1/16"

4 7/8"4 5/8"

4 1/4"

4"

G

H

F

D

B

56

56

0

1

2

3

0

2

4

6

8

10

NPSH [m]NP

SH[ft]

A

C

E

G

J

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.00.10.20.30.40.50.60.70.80.91.0

0 10 20 30 40 50 60 70 80

PP [kW

]Pp[HP]

Q [US gpm]

B

D

F

H

NPV/12

5SL 1

 1/4 x 1 1/2 ‐6

_60H

z_4_

0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 11: NPV - xylem.com

PAGE 11

Commercial WaterGoulds Water Technology

NPV PERFORMANCE CURVES – 60 HZ, 1750 RPM CURVAS DE RENDIMIENTO NPV – 60 HZ, 1750 RPM

NPV/150SL 1 1/2 x 2 - 6 1750 rpm ANSI/HI 14.6 - Grade 2B

0 1 2 3 4 5

0 10 20 30 40 50 60 70Q [Imp gpm]    

Q [l/s]

AB

C

62.4

64.6

63.6

62.2

53.9

63

63

5959

55

55

5044

G

0 5 10 15 20

0

5

10

15

20

25

30

0

5

10

15

20

25

30Q [m3/h]

H [m]H[

ft]

5 1/8"

5"

4 3/4"

4 3/8"

4"

4 1/2"

3 5/8"

F

E

D

62

62

0

2

4

6

0

5

10

15

20

25

NPSH [m]NP

SH[ft]

A

CD

E

G

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.00.10.20.30.40.50.60.70.80.91.0

0 10 20 30 40 50 60 70 80 90

PP [kW

]Pp[HP]

Q [US gpm]

B

F

NPV/15

0SL 1

 1/2 x 2 ‐6

_60H

z_4_

0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 12: NPV - xylem.com

PAGE 12

Commercial WaterGoulds Water Technology

NPV PERFORMANCE CURVES – 50 HZ, 2900 RPM CURVAS DE RENDIMIENTO NPV – 50 HZ, 2900 RPM

NPV/100SL 1x1 1/4-6 2900 rpm ANSI/HI 14.6 - Grade 2B

0.0 0.5 1.0 1.5 2.0 2.5 3.0

0 10 20 30 40Q [Imp gpm]    

Q [l/s]

A

D

46.6

48.1

47.1

45.6

48

47

46

46

45

45

43

43

40

C

0 3 6 9

0

5

10

15

20

25

30

35

0

20

40

60

80

100

120Q [m3/h]

H [m]H[

ft]

6 1/8"

B

4 3/4"

4 7/16"

5 3/16"

5 3/4"

D

E

4 1/16"

F

0

1

2

3

4

0

5

10

15

NPSH [m]NP

SH[ft]

AF

C

A

B

D

F

0.0

0.5

1.0

0.0

0.5

1.0

1.5

2.0

0 10 20 30 40 50

PP [kW

]

Pp[HP]

Q [US gpm]

C

E

NPV/10

0SL 1

x1 1/4‐6_5

0Hz_2_

0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 13: NPV - xylem.com

PAGE 13

Commercial WaterGoulds Water Technology

NPV PERFORMANCE CURVES – 50 HZ, 2900 RPM CURVAS DE RENDIMIENTO NPV – 50 HZ, 2900 RPM

NPV/125SL 1 1/4 x 1 1/2 - 6 2900 rpm ANSI/HI 14.6 - Grade 2B

0 1 2 3 4 5 6 7

0 Q [Imp gpm]      

Q [l/s]

A

C

E

60.1

64.0

64.9

64.4

63.8

63

63

57

57

544943

J

0 5 10 15 20 25

0

5

10

15

20

25

30

0

20

40

60

80

100

120Q [m3/h]

H [m]H[

ft]

6 1/8"

5 3/4"

5 1/16"

4 5/8"

4"

60

60

G

5 15/16"

B

D

66.0

5 11/32"

F

H

4 1/4"

4 7/8"

0

5

10

0

10

20

30

40

NPSH [m]NP

SH[ft]

A

C

E

GJ

0

1

2

3

0.00.51.01.52.02.53.03.54.04.55.0

0 20 40 60 80 100 120

PP [kW

]Pp[HP]

Q [US gpm]

B

D

FH

NPV/12

5SL 1

 1/4 x 1 1/2 ‐6

_60H

z_2_

0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 14: NPV - xylem.com

PAGE 14

Commercial WaterGoulds Water Technology

NPV/150SL 1 1/2 x 2 - 6 2900 rpm ANSI/HI 14.6 - Grade 2B

0 1 2 3 4 5 6 7 8 9

0 25 50 75 100 Q [Imp gpm]    

Q [l/s]

AB

C

66.6

68.167.3

65.7

61.6

67

67

61

61

57

57

5145

G

0 5 10 15 20 25 30

0

5

10

15

20

0

10

20

30

40

50

60

70

80Q [m3/h]

H [m]H[

ft]

5 1/8"

5"

4 3/4"

4 3/8"

E

3 5/8"

65

65

D

F

4 1/2"

4 1/16"

0

2

4

6

0

5

10

15

20

NPSH [m]NP

SH[ft]

AB

C

E

G

0

1

2

0

1

2

3

4

0 25 50 75 100 125 150

PP [kW

]

Pp[HP]

Q [US gpm]

F

D

NPV/15

0SL 1

 1/2 x 2 ‐6

_50H

z_2_

0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 15: NPV - xylem.com

PAGE 15

Commercial WaterGoulds Water Technology

SR – OPEN IMPELLER VERSION, VERSIÓN DE IMPULSOR ABIERTONPV PERFORMANCE CURVES – 60 HZ, 3500 RPM, CURVAS DE RENDIMIENTO NPV – 60 HZ, 3500 RPM

NPV/100SR 1x1 1/4-6 3500 rpm ANSI/HI 14.6 - Grade 2B

0 1 2 3 4 5 6

0 10 20 30 40 50 60 70 80Q [Imp gpm]    

Q [l/s]

G

B

31.0

32.3

32.3

32.6

33.7

25

32

32

30

30

2520

0 3 6 9 12 15 18 21

0

5

10

15

20

25

30

0

10

20

30

40

50

60

70

80

90

100Q [m3/h]

H [m]H[

ft]

5 3/8"

C

4 "

3 1/2"

4 5/16"

5 "

A

E

3"

FD

H

3 3/4 "

3 1/4 "

0

2

4

6

8

0

10

20

30

NPSH [m]NP

SH[ft]

G

F

B

G

BB

F0

1

2

3

0

1

2

3

4

5

0 10 20 30 40 50 60 70 80 90 100

PP [kW

]

Pp[HP]

Q [US gpm]

C

D

CCCA

C

E

H

NPV/10

0SR 1x1 1/4‐6_

60Hz

_2_0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 16: NPV - xylem.com

PAGE 16

Commercial WaterGoulds Water Technology

NPV/125SR 1 1/4 x 1 1/2 - 6 3500 rpm ANSI/HI 14.6 - Grade 2B

0 2 4 6 8 10

0 20 40 60 80 100 120 140Q [Imp gpm]    

Q [l/s]

A

D

43.7

44.1

44.3

44.4

44.6

44

42

42

40

40

30

0 5 10 15 20 25 30 35 40

0

5

10

15

20

25

30

35

0

20

40

60

80

100

120Q [m3/h]

H [m]H[

ft]

5 5/16"

C

4 5/16"

3 3/4"

4 5/8"

5 1/16"

B

EFG

4 1/16 "

3 7/16 "

0

2

4

6

0

5

10

15

20

25

NPSH [m]NP

SH[ft]

GD

A

A

B

D

G

0

1

2

3

0

1

2

3

4

5

0 20 40 60 80 100 120 140 160 180

PP [kW

]

Pp[HP]

Q [US gpm]

F

C

E

NPV/12

5SR 1 1/4 x 1

 1/2 ‐6_

60Hz

_2_0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 17: NPV - xylem.com

PAGE 17

Commercial WaterGoulds Water Technology

SR – OPEN IMPELLER VERSION, VERSIÓN DE IMPULSOR ABIERTONPV PERFORMANCE CURVES – 60 HZ, 3500 RPM, CURVAS DE RENDIMIENTO NPV – 60 HZ, 3500 RPM

NPV/150SR 1 1/2 x 2 - 6 3500 rpm ANSI/HI 14.6 - Grade 2B

0 2 4 6 8 10 12 14 16 18

0 50 100 150 200 Q [Imp gpm]    

Q [l/s]

A

D

51.4

51.8

52.1

50.0

52

50

50

45

45

40

0 10 20 30 40 50 60

0

5

10

15

20

25

30

35

0

20

40

60

80

100

120Q [m3/h]

H [m]H[

ft]

5 7/16"

C

4 5/8"

4 3/16"

4 15/16"

5 1/4"

B

EF

G

4 7/16 "

3 3/4"

0

5

10

0

15

30

45

NPSH [m]NP

SH[ft]

GD

A

A

B

D

G

0

2

4

6

0

2

4

6

8

10

0 50 100 150 200 250 300

PP [kW

]

Pp[HP]

Q [US gpm]

F

C

E

NPV/15

0SR 1 1/2 x 2

 ‐6_

60Hz

_2_0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 18: NPV - xylem.com

PAGE 18

Commercial WaterGoulds Water Technology

SR – OPEN IMPELLER VERSION, VERSIÓN DE IMPULSOR ABIERTONPV PERFORMANCE CURVES – 60 HZ, 1750 RPM, CURVAS DE RENDIMIENTO NPV – 60 HZ, 1750 RPM

NPV/100SR 1x1 1/4-6 1750 rpm ANSI/HI 14.6 - Grade 2B

0.0 0.5 1.0 1.5 2.0 2.5

0 5 10 15 20 25 30 35Q [Imp gpm]    

Q [l/s]

G

B

31.7

32.1

32.2

32.7

32.6

30

30

2520

0 2 4 6 8 10

0

1

2

3

4

5

6

7

0

5

10

15

20

25Q [m3/h]

H [m]H[

ft]

5 3/8"

C

4 "

3 1/2"

4 5/16"

5 "

A

E

3"

FD

H

3 3/4 "

3 1/4 "

25

0

2

4

6

0

10

20

NPSH [m]NP

SH[ft]

G

F

B

G

B

F0.0

0.2

0.4

0.0

0.2

0.4

0.6

0 5 10 15 20 25 30 35 40 45

PP [kW

]

Pp[HP]

Q [US gpm]

DC

A

E

H

NPV/10

0SR 1x1 1/4‐6_

60Hz

_4_0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 19: NPV - xylem.com

PAGE 19

Commercial WaterGoulds Water Technology

SR – OPEN IMPELLER VERSION, VERSIÓN DE IMPULSOR ABIERTONPV PERFORMANCE CURVES – 60 HZ, 1750 RPM, CURVAS DE RENDIMIENTO NPV – 60 HZ, 1750 RPM

NPV/125SR 1 1/4 x 1 1/2 -6 1750 rpm ANSI/HI 14.6 - Grade 2B

0 1 2 3 4 5

0 10 20 30 40 50 60 70Q [Imp gpm]    

Q [l/s]

A

D

41.6

42.3

42.5

42.6

42.8

42

40

40

38

40

30

0 5 10 15 20

0

1

2

3

4

5

6

7

8

9

0

5

10

15

20

25

30Q [m3/h]

H [m]H[

ft]

5 5/16"

C

4 5/16"

3 3/4"

4 5/8"

5 1/16"

B

EFG

4 1/16 "

3 7/16 "

0

1

2

3

0

5

10

NPSH [m]NP

SH[ft]

GD

A

A

B

D

G 0.0

0.2

0.4

0.0

0.2

0.4

0.6

0 10 20 30 40 50 60 70 80 90

PP [kW

]

Pp[HP]

Q [US gpm]

F

C

E

NPV/12

5SR 1 1/4 x 1

 1/2 ‐6

_60H

z_4_

0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 20: NPV - xylem.com

PAGE 20

Commercial WaterGoulds Water Technology

NPV/150SR 1 1/2 x 2 - 6 1750 rpm ANSI/HI 14.6 - Grade 2B

0 1 2 3 4 5 6 7 8

0 20 40 60 80 100 Q [Imp gpm]    

Q [l/s]

A

D

48.749.1

50.1

49.5

48.1

50

48

48

43

43

0 5 10 15 20 25 30

0

1

2

3

4

5

6

7

8

9

0

5

10

15

20

25

30Q [m3/h]

H [m]H[

ft]

5 7/16"

C

4 5/8"

4 3/16"

4 15/16"

5 1/4"

B

EF

G

4 7/16 "

3 3/4"

0

1

2

3

4

0

5

10

15

NPSH [m]NP

SH[ft] G

D A

A

B

D

G

0.00

0.25

0.50

0.00

0.25

0.50

0.75

1.00

0 20 40 60 80 100 120 140

PP [kW

]

Pp[HP]

Q [US gpm]

F

C

E

NPV/15

0SR 1 1/2 x 2

 ‐6_

60Hz

_4_0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 21: NPV - xylem.com

PAGE 21

Commercial WaterGoulds Water Technology

SR – OPEN IMPELLER VERSION, VERSIÓN DE IMPULSOR ABIERTONPV PERFORMANCE CURVES – 50 HZ, 2900 RPM, CURVAS DE RENDIMIENTO NPV – 50 HZ, 2900 RPM

NPV/100SR 1x1 1/4-6 2900 rpm ANSI/HI 14.6 - Grade 2B

0 1 2 3 4 5

0 10 20 30 40 50 60 Q [Imp gpm]    

Q [l/s]

G

B

31.6

31.7

32.2

32.6

32.832

32

30

30

2520

0 3 6 9 12 15 18

0

5

10

15

20

0

10

20

30

40

50

60

70

80Q [m3/h]

H [m]H[

ft]

5 3/8"

C

4 "

3 1/2"

4 5/16"

5 "

A

E

3"

FD

H

3 3/4 "

3 1/4 "

25

0

2

4

6

8

0

10

20

30

NPSH [m]NP

SH[ft] G

F

B

G

B

F

0

1

2

0

1

2

3

0 10 20 30 40 50 60 70 80

PP [kW

]

Pp[HP]

Q [US gpm]

DC

A

E

H

NPV/10

0SR 1x1 1/4‐6_

50Hz

_2_0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 22: NPV - xylem.com

PAGE 22

Commercial WaterGoulds Water Technology

NPV/125SR 1 1/4 x 1 1/2 - 6 2900 rpm ANSI/HI 14.6 - Grade 2B

0 1 2 3 4 5 6 7 8

0 20 40 60 80 100 Q [Imp gpm]    

Q [l/s]

A

D

43.6

44.2

44.4

44.5

44.7

44

42

42

40

40

30

0 5 10 15 20 25 30

0

5

10

15

20

0

10

20

30

40

50

60

70

80Q [m3/h]

H [m]H[

ft]

5 5/16"

C

4 5/16"

3 3/4"

4 5/8"

5 1/16"

B

EFG

4 1/16 "

3 7/16 "

0

1

2

3

4

0

5

10

15

NPSH [m]NP

SH[ft]

G D

A

A

B

D

G

0

1

2

0

1

2

3

0 20 40 60 80 100 120 140

PP [kW

]

Pp[HP]

Q [US gpm]

F

C

E

NPV/12

5SR 1 1/4 x 1

 1/2 ‐6_

50Hz

_2_0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 23: NPV - xylem.com

PAGE 23

Commercial WaterGoulds Water Technology

SR – OPEN IMPELLER VERSION, VERSIÓN DE IMPULSOR ABIERTONPV PERFORMANCE CURVES – 50 HZ, 2900 RPM, CURVAS DE RENDIMIENTO NPV – 50 HZ, 2900 RPM

NPV/150SR 1 1/2 x 2 - 6 2900 rpm ANSI/HI 14.6 - Grade 2B

0 2 4 6 8 10 12 14

0 50 100 150 200Q [Imp gpm]    

Q [l/s]

A

D

50.951.3

51.6

50.0

52

50

50

45

45

40

0 10 20 30 40 50

0

5

10

15

20

0

10

20

30

40

50

60

70

80Q [m3/h]

H [m]H[

ft]

5 7/16"

C

4 5/8"

3/16"

4 15/16"

5 1/4"

B

EF

G

4 7/16 "

3 3/4"

0

2

4

6

8

0

10

20

30

NPSH [m]NP

SH[ft]

GD A

A

B

D

G

0

1

2

3

0

1

2

3

4

5

0 50 100 150 200 250

PP [kW

]

Pp[HP]

Q [US gpm]

F

C

E

NPV/15

0SR 1 1/2 x 2

 ‐6_

50Hz

_2_0

* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Page 24: NPV - xylem.com

PAGE 24

Commercial WaterGoulds Water Technology

NPV PUMP – DIMENSIONS, WEIGHTS AND SPECIFICATIONSBOMBA NPV – DIMENSIONES, PESOS Y ESPECIFICACIONES

Dimensions – Determined by Pump, Dimensiones – Determinadas por la Bomba

Max. Wt. Pump, Suction NPT, Discharge NPT, Pump only, Bomba Succión NPT Descarga NPT Peso máx., Bomba sola. 1SL/1SR 11/4 1 43/8 2 7.78 17.78 13.20 23.20 14.68 24.68 65 2SL/SR 11/2 11/4 41/2 21/8 7.78 17.78 13.20 23.20 14.68 24.68 70 3SL/SR 2 11/2 45/8 21/8 7.78 17.78 13.20 23.20 14.68 24.68 70

“X” “Y”

NOTES:

1. Motor dimensions may vary with motor manufacturers.

2. Dimensions in inches, weights in pounds.

3. For explosion proof motor dimensions consult factory for information.

4. Not to be used for construction purposes unless certified.

NOTAS:

1. Las dimensiones del motor puede que varíen con los fabricantes.

2. Dimensiones en pulgadas, pesos en libras.

3. Para las dimensiones de los motores a prueba de explosión consultar con la fábrica para información.

4. No usar para propósitos de construcción sin certificar.

1/2 16 21 47 19 18 27 103/16

3/4 19 24 41 21 21 30 107/16

1 22 26 49 23 21 30 111/16

11/2 28 35 56 27 27 37 1115/16

2 33 39 60 32 33 44 1211/16

3 40 43 — 41 37 — 139/16

5 50 — — 50 — — 139/16

71/2 — — — 49 — — 14

Available Motor Weights and Dimensions,Pesos y Dimensiones de Motores que se ofrecen

HPC Max. Length,(Longitud)

Dimensions in inches, weights in pounds., Dimensiones en pulgadas, pesos en libras.* Premium efficiency where required by Department of Energy regulations.

Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

ODP* TEFC*ODP* TEFC* EXP* EXP*1 Phase, Monofásicos 3 Phase, Trifásicos

Motor Weights, Pesos del Motor

SUCTIONSUCCIÓN

8.68“X”“Y”

DISC

HARG

ED

ESC

ARG

A

“R”

A

B B1.50REF.

C M

AX.

C M

ÁX.

6.50 DIA. MAX.7.00 DIA.

7,00 DIAM.6,50 DIAM. MÁX.

“N”

6.0"

MIN

IMUM

LIQ

UID

LEVE

L6,

0" M

ÍNIM

O N

IVEL

D

EL L

ÍQU

IDO

OPTIONAL MOUNTING ACCESSORIESACCESORIOS DE MONTAJE OPCIONALES

5.97

5.97

.56 DIA.TYPICAL

,56 DIAM.,TÍPICO

CLEARANCE HOLEAGUJERO DE PASO

.56 DIA.TYPICAL

,56 DIAM.,TÍPICO

VIEW “A-A”MOUNTING PLATE

VISTA A-APLACA DE MONTAJE

VIEW “B-B”MOUNTING CLAMP

VISTA B-B ABRAZADERA DE MONTAJE

MP1

MC1

.75TYPICAL

,75 TÍPICO

9.5 REF.9,5 REF.

14.0

REF

.14

,0 R

EF.

15.5

0

11.00

6.25

5.25

5/8" DIA.5⁄8" DIAM.

“M”

Dimensions Determined by Shaft, Dimensiones Determinadas por el Eje M N R 14" 24" 14" 24" 14" 24"

A

.50

Page 25: NPV - xylem.com

PAGE 25

Commercial WaterGoulds Water Technology

Specifically designed for Tank Mounted applications traditionally requiring various materials such as all iron, bronze fitted or all bronze construction.

• Machine coolant recirculation

• Part washer

• Liquid transfer

• Spray system

• Chillers

• Washing/cleaning systems

• OEM applications

• General purpose sump and tank draining

NPV TYPICAL APPLICATIONSAPLICACIONES TÍPICAS NPV

Diseñadas específicamente para aplicaciones de tanques montados, requiriendo tradicionalmente varios materiales, tales como todo de hierro, accesorios de bronce o toda la construcción de bronce.

• Recirculación del refrigerante de la máquina

• Lavador de pieza

• Transferencia de líquidos

• Sistemas de aspersión

• Enfriadores

• Sistemas de lavado/limpieza

• Aplicaciones del fabricante del equipo original

• Sumidero y tanque de desagüe para uso general

NPV SPECIFICATIONSESPECIFICACIONES NPV

Capacities to: 125 GPM (L/min) at 1750 RPM 245 GPM (L/min) at 3500 RPM

Heads to: 38 feet (11 m) at 1750 RPM 150 feet (50 m) at 3500 RPM

Working pressures to: 125 PSIG (9 bars)

Maximum temperatures to: 250°F (121°C)

Direction of rotation: Clockwise when viewed from motor end.

Especificaciones de motores: Armazón 56J NEMA, 1750 RPM

1⁄2 HP y 3⁄4 HP. 3500 RPM 1⁄2 a 71⁄2 HP CF. A prueba de goteo*, totalamente cerrados y enfriados con ventilador* o en cubiertas a prueba de explosión*. Eje de acero inoxidable con balineras de bolas.

Monofásicos: Voltaje 115/230 abiertos a prueba de goteo* y totalmente cerrados y enfriados con ventilador*. (modelo 3 HP – 230 voltios solamente) Se proporciona protección térmica contra sobrecarga construida con reseteo automático.

Trifásicos: Voltaje 208-230/460 abiertos a prueba de goteo*, totalmente cerrados y enfriados con ventilador* y a prueba de explosión.

NOTA: Para motores trifásicos se debe de proporcionar la protección térmica contra sobrecarga en la unidad de arranque. El arrancador y los calentadores se deben pedir por separado.

* Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Motor specifications: NEMA 56J frame, 1750 RPM, 1⁄2 HP and 3⁄4 HP. 3500 RPM 1⁄2 through 71⁄2 HP. Open drip-proof*, totally enclosed fan-cooled* or explosion proof enclosures*. Stainless steel shaft with ball bearings.

Single phase: Voltage 115/230 ODP* and TEFC*. (3 HP model – 230 V only) Built-in overload with auto-reset provided.

Three phase: Voltage 208-230/460 ODP*, TEFC* and EX PROOF.

NOTE: For three phase motors, overload protection must be provided in starter unit. Starter and heaters must be ordered separately.

* Premium efficiency where required by Department of Energy regulations.

Capacidades:125 GPM (L/min) a 1750 RPM 245 GPM (L/min) a 3500 RPM

Alturas de carga a: 39 pies (11 m) a 1750 RPM 150 pies (50 m) a 3500 RPM

Presión de trabajo:125 lib/pulg

2 (9 barias)

Temperatura máxima:250 °F (121°C)

Dirección de rotación: En dirección de las agujas del reloj visto desde el extremo final del motor.

Page 26: NPV - xylem.com

PAGE 26

Commercial WaterGoulds Water Technology

NOTESNOTAS

Page 27: NPV - xylem.com

PAGE 27

Commercial WaterGoulds Water Technology

NOTESNOTAS

Page 28: NPV - xylem.com

Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license. WaterGun is a trademark of Xylem Inc. or one of its subsidiaries. © April Xylem Inc. BNPV R4 April 2021

Xylem Inc.2881 East Bayard Street Ext., Suite ASeneca Falls, NY 13148Phone: (866) 325-4210 Fax: (888) 322-5877www.xylem.com/goulds

1) The tissue in plants that brings water upward from the roots;2) a leading global water technology company.

We’re a global team unified in a common purpose: creating innovative solutions to meet our world’s water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation.

For more information on how Xylem can help you, go to www.xylem.com

Xylem

1) El tejido en las plantas que hace que el agua suba desde las raíces;2) una compañía líder global en tecnología en agua.

Somos un equipo global unido por un propósito común: crear soluciones innovadoras para satisfacer las necesidades de agua de nuestro mundo. Desarrollar nuevas tecnologías que mejorarán la manera en que se usa, se conserva y se reutiliza el agua en el futuro es un aspecto crucial de nuestra labor. Transportamos, tratamos, analizamos y retornamos el agua al medio ambiente, y ayudamos a las personas a usar el agua de manera eficiente, en sus casas, edificios, fábricas y campos. Desde hace mucho tiempo y en más de 150 países, tenemos relaciones sólidas con clientes que nos conocen por nuestra potente combinación de marcas de producto líderes y conocimientos de aplicación, con el respaldo de nuestro legado de innovación.

Para obtener más información, visite xylem.com

Xylem