note the instrument’s name & manufacturer

20
1 Note the instrument’s name & manufacturer Record these procedures in your notebook. You will be given a timed quiz over these procedures. Yes, you may use your notes when taking the quiz. The instrument is on if the two lights are flashing

Upload: nieve

Post on 05-Jan-2016

36 views

Category:

Documents


0 download

DESCRIPTION

The instrument is on if the two green lights are flashing. Note the instrument’s name & manufacturer. Record these procedures in your notebook. You will be given a timed quiz over these procedures. Yes, you may use your notes when taking the quiz. 2.click OK. 1. click easy OMNIC. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Note the instrument’s name & manufacturer

1

Note the instrument’s name & manufacturer

Record these procedures in your notebook.

You will be given a timed quiz over these procedures. Yes, you may use your notes when taking the quiz.

The instrument is on if the two greenlights are flashing

Page 2: Note the instrument’s name & manufacturer

2

2.click OK

1. clickeasy OMNIC

3.click later

0.A good place to start, “Is the instrument working today DrG?

Page 3: Note the instrument’s name & manufacturer

3

4. set the instrument default to “Smart Golden Gate”

Page 4: Note the instrument’s name & manufacturer

4

5. Have the ZnSe plate open & exposed to the atmosphere

Page 5: Note the instrument’s name & manufacturer

5

Clean with methylene chloride on a kimwipe and wipe instrument clean of sample if found like the figure on the left

Page 6: Note the instrument’s name & manufacturer

6

6.click “collect background”

7.confirm the ZnSe plate is open to the atmosphere, then ckick okay

Page 7: Note the instrument’s name & manufacturer

7

8.wait till all scans are complete, then click yes, “add background to window.”

Page 8: Note the instrument’s name & manufacturer

8

9.add the sample using a capillary tude and cover it with the glass plate.

Page 9: Note the instrument’s name & manufacturer

9

11.click collect sample

12.click okay

13.click okay

Page 10: Note the instrument’s name & manufacturer

10

14.click yes, “add spectrum to window.”

Page 11: Note the instrument’s name & manufacturer

1115.click “<-” selection tool

16. select the blue background

Page 12: Note the instrument’s name & manufacturer

12

17.click to clear the “red” highlighted background

Page 13: Note the instrument’s name & manufacturer

13

18.click Find Peaks and black threshold bar will appear

19.threshold bar moves where the cursor is clicked. Peaks are automatically selected.

Page 14: Note the instrument’s name & manufacturer

14

20.threshold bar moves where the cursor is clicked. Peaks are automatically selected.

Page 15: Note the instrument’s name & manufacturer

15

21.click REPLACE,Don’t forget to do this

Page 16: Note the instrument’s name & manufacturer

1622.click “T” for text

23.click

Type your name, sample name, unk# sample type, then click “enter”

24.click print

Page 17: Note the instrument’s name & manufacturer

17

25. click file, select file “Save As”

Page 18: Note the instrument’s name & manufacturer

18

26. select the location the file will be saved to. BRING A USB DRIVE

27. select file type as “windows metafile”28. Give the file a simple name like “FTIR69.wmf”

FTIR69.wmf

before saving.

Page 19: Note the instrument’s name & manufacturer

19

29.place methylene chloride on a kimwipe and wipe instrument clean of sample

Page 20: Note the instrument’s name & manufacturer

20

Review your notes because you may be given a timed quiz over the set-up and use of the instrument.

I am hope you took accurate notes.

Yes, may use your notes when taking the quiz.