nodebv100r008 operation and maintenance
DESCRIPTION
NSTTRANSCRIPT
www.huawei.com
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
NodeB Operation and Maintenance
Page2Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Objectivesl Upon completion of this course, you will be able to:
p Know the structure of operation and maintenance system
p Master routine operation and maintenance of NodeB
Page3Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Contents1. Operation and Maintenance System
2. NodeB Routine Operation
3. NodeB Routine Maintenance
Page4Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Operation and Maintenance System Structure
lTwo ways of NodeB operation and maintenance:[Near end[Far end
VLANLMT
LMT NodeB
NodeB
RNC
iManager M2000
LMT
IPoA
IPoE
IPoEIPoA
Page5Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Operation and Maintenance Software (LMT)l Summarize
p LMT: Local Maintenance Terminall Composition
p Local Maintenance Terminalp Trace Viewerp Monitor Viewer
l Mode of operationp GUI (Graphic User Interface)p MML (Man Machine Language) command
Page6Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Operation and Maintenance Interface
1-Menu bar 2-Tool bar 3-Navigation tree pane 4-Object pane 5-Output pane 6-Status bar
Page7Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Trace Viewer Interface
1-Menu bar 2-Toolbar
3-[Message Browse] pane
12
3
l In Local Maintenance Terminal, click [View/Trace Viewer] or
Page8Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Monitor Viewer Interface
1-Menu bar 2-Toolbar
3-Status pane
12
3
l In Local Maintenance Terminal, click [View/Monitor Viewer] or
Page9Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Contents1. Operation and Maintenance System
2. NodeB Routine Operation
3. NodeB Routine Maintenance
Page10Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Routine Operation Itemsl Authority managementl Alarm managementl Cell managementl Equipment managementl Iub interface managementl Tracing managementl System managementl Real-time state monitoring
Page11Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Authority managementl Login to NodeB through LMT
p Choose Start > All programs > HUAWEI Local Maintenance Terminal > Local Maintenance Terminal or click the icon of
LMTp Add or choose an office
p Input right password
l Change Login Passwordp Choose Authority > Change Password
l Lock LMT p Lock Now
p Lock by schedule
Page12Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Alarm ManagementAlarm TypesAlarm Types
l Classified by Naturep Fault alarmp Event alarm
l Classified by Alarm Statep Active alarmp Recovery alarm
l Classified by Network Managementp Power system alarmp Environment system alarmp Signaling system alarmp Trunk system alarmp Hardware system alarm p Software system alarmp Running system alarmp Communication system alarmp QoS alarmp Processing error alarm
Page13Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Alarm ManagementAlarm SeverityAlarm Severity
l Critical Alarmp The critical Alarm has an impact on the service provided by
the system. It requires timely handling
l Major Alarmp The major alarm affect QoS. It requires immediate handling
l Minor Alarmp The minor alarm does not affect QoS. It requires handling
at a proper time against potential faults
l Warningp The warning shows a potential error that may affect service.
It may require handling in some cases
Page14Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Alarm Managementl Alarm browse window
p Choose Fault Management/ Browse Alarm or click
Page15Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
l Querying Alarm Details p Double click an alarm record in the alarm browse window
p Click the button of “More” to query related information
Alarm Management
Page16Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
l Querying Alarm Logsp Choose Fault Management > Query Alarm Log or click the
shortcut icon
Alarm Management
Page17Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
l Querying Alarm Logsp Alarm log window
Alarm Management
l Saving Alarmsp Right click alarm records and choose “save… alarms”
Page18Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Cell Managementl Querying Cell Status
p Query the status of the local cell and the logical cell: DSP LOCELL
l Querying Cell Configurationp Query the local cell configuration: LST LOCELLp Query the logical cell configuration: DSP CELLCFG
l Modifying Local Cell Parametersp MOD LOCELL
l Blocking/Unblocking Local Cellp Block a local cell: BLK LOCELLp Unblock a local cell: UBL LOCELL
Page19Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Equipment ManagementBasic Operation on Device PanelBasic Operation on Device Panel
l Performing following operations on device panel:
p Querying the board status
p Querying the board version
p Resetting the board (the MAFU doesn’t support this function)
l Opening device panelp In the navigation pane, click the Maintenance tab.
Double-click Topology Management > Main Cabinet
Page20Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Equipment ManagementOperation on Device PanelOperation on Device Panel
Page21Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Equipment ManagementNodeBNodeB--Level OperationLevel Operation
l Operations on the NodeBp Querying the NodeB Running Version
LST VERp Querying the NodeB Software Version
LST SOFTWARE p Resetting the NodeB
RST SYS
Page22Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Equipment ManagementBoardBoard--Level OperationLevel Operation
l Operations on the Board p Querying Board Status
DSP BRDp Querying Board Version
DSP BRDVERp Blocking Board
BLK BRD p Unblocking Borad
UBL BRD
Page23Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Equipment ManagementBoardBoard--Level OperationLevel Operation
l Operations on the Board p Resetting Board
RST BRD p Adding board
ADD BRD p Removing board
RMV BRD
Page24Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Equipment Management
l Querying NodeB Present Timep DSP TM
l Modifying NodeB Present Timep MOD TM
l Displaying Current Clock Status of NodeBp DSP CLKSTAT
l Modifying the reference clock source of NodeBp SET CLKMODE
Time and Clock MaintenanceTime and Clock Maintenance
Page25Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Iub Interface managementl Querying Physical Layer Status
p Querying E1T1 Status
DSP E1T1p Querying E1/T1 work mode
DSP E1T1WORKMODEp Querying STM-1 Status
DSP STM1p Querying STM-1 Work Mode
DSP STM1WORKMODE
Page26Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Iub Interface managementl Querying Transport Layer Status
p Display AAL2 node statusDSP AAL2NODE
p Display AAL2 path statusDSP AAL2PATH
p Display the status of all NCP/CCP portsDSP IUBCP
p Display IMA group statusDSP IMAGRP
p Display IMA link statusDSP IMALNK
Page27Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
l Creating a Tracing Taskp In the navigation pane, click the Maintenance tab.
Choose Trace Management > Interface Trace Task.
Then double-click Standard Signaling Interface Tracing
Tracing Management
Page28Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
l Standard Signaling Interface Tracing window
Tracing Management
l Browsing a NodeB Traced Message Online p Double click a message in tracing window
Page29Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
l NodeB Iub Interface Signaling Tracingp Saving NodeB Traced Messages Automatically
Open Standard Interface Tracing dialog box,
select Auto Savep Saving NodeB Traced Messages Manually
Select the messages to be saved, right-click on the
messages and select Save Selected Messages on
the shortcut menu
Tracing Management
l Browsing NodeB Message Files Offlinep In Local Maintenance Terminal, click [View/Trace Viewer]
or
Page30Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
System Management
l Download NodeB Softwarep DLD SOFTWARE
l Activate Software Version p ACT SOFTWARE
l Synchronize Software Version p SYN SOFTWARE
Software Management Software Management
Page31Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
System ManagementFile Management File Management
l Device Archivep Export Device File (Generated in NodeB)
EXP DEVFILEp Upload Device File (NodeB to FTP)
ULD DEVFILE
Page32Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
System ManagementFile Management File Management
l Operation & Maintenance Log Filep ULD FILE (NodeB to FTP)
n Operation Log
n Main Board Log Files
n Board Log Files
n RTWP Routine Test Log File
Page33Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
System ManagementFile Management File Management
l Data Configuration Filep GUI Mode
p In the navigation pane, click the Maintenance tab. Double-
click Software Management > Data Config File Transfer
Page34Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
System ManagementFile Management File Management
l Data Configuration Filep MML Mode-Download Data File (FTP to NodeB)
DLD CFGFILE
-Upload Data File (NodeB to FTP)
ULD CFGFILE
Page35Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Real-time State Monitoringl Classification of Monitoring task
p CPU/DSP Occupancy
p Cell Service Resource
p Board Service Resource
p NodeB Output Power
p NodeB RTWP
l Create a Monitoring taskp Choose Maintenance > Realtime Specific Monitoringp Choose a sub-node to create a monitor task
Page36Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Contents1. Operation and Maintenance System
2. NodeB Routine Operation
3. NodeB Routine Maintenance
Page37Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Basic Mission of Maintenance
The state are normalDSP CLKSTATClock
The value is within normal rangeReal-time state monitoringRTWP
Transmit power between the NodeB and the RNC is consistent
Real-time state monitoringTx power
The states are availableDSP AAL2NODE, DSP AAL2PATH,DSP IUBCP
Transport layer
The states are availableDSP E1T1, DSP STM1DSP IMAGRP, DSP IMALNKPhysical layer
Cell is setup and enabledDSP LOCELLCell state
No event alarms that affect system servicesAlarm management systemEvent alarm
No fault alarmsAlarm management systemFault alarm
ALM is offBoards or device panelIndicator state
Reference standardOperation guideItem
Thank youwww.huawei.com