niederspannungs- leistungsschalter compact merlin...
TRANSCRIPT
MERLIN GERIN
compact
NS
41
push
totrip
tripped
OOFF
reset
1 2 Nm
test k
it 43362/36701/29118
MERLIN
GERIN
1
2
3
4
Im
Ih(S
)
(T)
testbat
connection
connecting to
STR22...58
connection
connecting to
ST108...418
testS
T
select
push
totrip
5
4
ON
2
push
totrip
ex: In 160A
Io = In x .9 = 144A
Ir = Io x .95 = 136.8A
Im = Ir x 6 = 820.8A
OFF
1
tripped
43362
1,5 A
23
4
5
67
8
10
xIr
Im
.8.85
.88
.9
.93.95
.98
1
xIo
IrSTR 22 SE
alarm %
Ir90
105 test
ImIr
In=160A
64/160
A
.5.63
.7
.8
.91
xIn
Io
3
23
4
5
67
8
10
xIr
Im
.8.85
.88
.9
.93.95
.98
1
xIo
IrSTR 22 SE
alarm %
Ir90
105 test
ImIr
In=160A
64/160
A
.5.63
.7
.8
.91
xIn
Io
.8.85
.88
.9
.93.95
.98
1
xIo
IrSTR 22 SE
.5.63
.7
.8
.91
xIn
Io
TESTSTR22 SE / GE
push
totrip
ex: In 160A
OFF
1
.8.85
.88
.9
.93.95
.98
1
xIo
IrSTR 22 SE
al
ImIr
In=160A
64/16
.5.63
.7
.8
.91
xIn
Io
TESTSTR22 SE / GE
8
6 x M5
6 x .2 in
8 mm
.31 in
cat no 29283
M
4
MERLIN GERIN
compact
NS
41
push
totrip
3
tripped
OOFF
reset
ONI
Nm
2
OFF
PUSH TO TRIP
MERLIN GERINcompact
C 1001 HUi 750V. Uimp 8kV.
Ue(V)
220/240
380/415
440
500/525
660/690
100
70
65
40
35
IEC 947-2UTE VDE BS CEI
UNE NEMA
Icu(kA)
cat B
Ics = 100% IcuIcw 8kA / 0,25s.
OFF
60 70 80 90 105 %Ir
STR 55UE
TFR
Io
xIn
T tr tmth
Ir ImIhI
test
fault
t
i
1.5
2
3
4 5
6
8
10xIr
Im
.63
.7
.8
.85 .9
.95
.98
1xIn
IrSTR 22 SE90
105%Ir
alarm
ImIr
I n = 2 5 0 A
250N
P93083
OFF
MERLIN GERINcompact
NS250 NUi 750V. Uimp 8kV.
220/240380/415440500660/690250
853635308
50
cat A
IEC947-2UTE VDE BS CEI UNE NEMA
Ue(V)
Icu(kA)
Ics=100% Icu
160/250Apushto
trip
pushto
trip
Ic
µP
>Ir
>Im
test faultSTR 53 UE 60 75 90 105 %Ir
IImIrIo
tr tm(s)
x Inx Irx Iox In
on I2t off(s) at 1.5 Ir
test
R
tr
tm
ImIr I
MERLIN GERINcompact
NS400 HUi 750V. Uimp 8kV.
Ue(V)
220/240
380/415
440
500/525
660/690
100
70
65
40
35
IEC 947-2UTE VDE BS CEIUNE NEMA
Icu(kA)
cat B
Ics = 100% IcuIcw 6kA / 0,25s
In = 400A
.8
1
.63
.5
.9 .93.95
.98
.88
.85
.8 1
4 56
8
3
2
1.5 10
4 68
10
3
2
1.5 12
.3 .3.2
.1
.2
.1
0 0
120 24060
30
15 240
.9 .93.95
.98
.88
.85
.8 1
pushto
trip
pushto
trip400
ex:
IoI
Niederspannungs-leistungsschalterCompact Merlin Gerin
Benutzerhandbuch
1Merlin Gerin
Inhalt
Entdecken Sie Ihren Leistungsschalter .................................... 3
Ihren Leistungsschalter einstellen ............................................. 9
Zusätzliche Funktionen ................................................................. 31
Betrieb ................................................................................... 39
Merlin Gerin2
3Merlin Gerin
Entdecken Sie Ihren Leistungsschalter
Leistungsschalter mit Kipphebelantrieb .................................. 4
Leistungsschalter mit Motorantrieb ........................................... 5
Leistungsschalter mit Drehantrieb ............................................. 7
Elektrisches Zubehör ....................................................................... 8
Merlin Gerin4
pushto
trip
OFF "O"
ON "I" Einschalten
Rückstellen
Ausgelöst
MERLIN GERINcompactNS160 HUi 750V. Uimp 8kV.Ue(V)220/240380/415440500/525660/690250
Icu(kA)1007065501085
cat AIcs = 100% Icu
IEC 947.2UTE VDE BS CEI UNE NEMA
Baureihe
Typ (Bemessungsstrom und Strombegrenzungsver
Genormte Kenndaten:v Ui = Bemessungsisolationsspannungv Uimp = Bemessungsstoßspannungv Ue = Bemessungsbetriebsspannungv Icu = Bemessungsgrenzkurzschlußausschaltvermv Ics = Bemessungsbetriebskurzschlußausschaltver
Farbkennzeichnung des Schaltertyps:v Gelb = Ev Silber = Nv Rosa = Hv Blau = Lv Grün = Schalter
Hauptschaltereigenschaftengemäß IEC 947-2
Wichtigste Normen, denender Schalter entspricht
Leistungsschalter mitKipphebelantrieb
Leistungsschild EindeutigeStellungsanzeigeDie Compact NS-Leistungsschalterhaben Trennereigenschaften undeindeutige Stellungsanzeigen gemäßIEC 947-1 und 947-2.
Die Trennstellung entspricht derAUS-Stellung des Kipphebels (Hebelauf 0).In dieser Stellung kann abgangsseitigin den Stromkreis eingegriffen werden.Es wird empfohlen, den Leistungs-schalter in der AUS-Stellung zuverriegeln und die für Arbeiten an NS-Stromkreise geltenden Vorsichts-maßnahmen zu beachten.
E32
507
Kipphebelantrieb Rückstellung nach AuslösungWenn der Leistungsschalter sich in der"Ausgelöst"-Stellung befindet, muß derKipphebel zur Rückstellung in die AUS-Stellung bewegt werden, bevor Sie denSchalterwieder einschalten (ON) kön-nen.
E32
506
E32
505
I
O
pushto
trip
I
O
MERLIN GERINcompactNS160 HUi 750V. Uimp 8kV.Ue(V)220/240380/415440500/525660/690250
Icu(kA)1007065501085
cat AIcs = 100% Icu
IEC 947.2UTE VDE BS CEI UNE NEMA
40/10040/100
STR 22 SE
test
+
In=100A
ImIr
STR 22 SEIm
x Ir102
3
45 6
7
8
Ir
x Io1.8
.85
.88.9 .93
.95
.98
-
90105
alarm
Io
x In
.5.63
.7.8 .9
1
%Ir
Anschluß oben
Befestigungsbohrung
Leistungsschild (siehe oben)
SchaltstellungsanzeigeEIN (I/ON)
Kipphebel(in "Ausgelöst"-Stellung)
SchaltstellungsanzeigeAUS (O/OFF)
Bezeichnungsschild
Auslöser-BemessungsstromAuslösetaste"push to trip"
Teststecker (sieheSeite 11)
Befestigungsbohrung
Anschluß unten
5Merlin Gerin
Motorantriebe für Leistungsschalter NS100 bis 630 Der Motorantrieb ermöglicht dasfernbetätigte Ein- und Ausschaltensowie die Rückstellung desLeistungsschalters mittels elek-trischer Befehle.Seine Position und seine geringen Ab-messungen beeinträchtigen den Zugriffauf und die Lesbarkeit der Einstel-lungen nicht. Er kann nach vorne ge-kippt werden, so daß die Anschlüsseund Zubehörteile zugänglich sind (volt-metrische Auslöser u. Meldekontakte).
(1) Schaltstellungsanzeige derHauptkontakte
Funktionszyklus im Hand-Betrieb
I ON
O OFF
EIN/geschlossen
AUS/getrennt
Die Trennstellung entspricht der OFF-Stellung (0).
(2) Speicherzustandsmeldung
(3) Umschalten Hand/automatisch :c Im Hand-Betrieb werden keineelektrischen Befehle erfaßt.c Im Automatik-Betrieb werden nurelektrische Befehle ausgeführt.
Funktionszyklus im Automatik-Betrieb
Manuelle Rückstellung
E32
508
E32
509
E32
510
E32
511
Die Motorantriebe
90 105 %IrSTR 53 UE >7560
tr
Im
x Ir101.5
2
34 5
6
8
.3 .32
tm(s)
Ir
x Io1.8
.85
.88.9 .93
.95
.98
120 240tr
Io
x In1.5
.63 .8
-+
I
x In121.5
2
34 6
8
10
Ih
x In1.2
.3
.4.5 .6
.7
.8
.4 .4.3
th (s)
T faulttest
µ P
> Ir
> Im
I ON charged
push ON
Ipush OFF
O
2
1manu auto
MERLIN GERINcompactNS400 HUi 750V. Uimp 8kV.Ue(V)
220/240380/415440500/525600/690
10070654035
IEC 947-2UTE VDE BS CEIUNE NEMA
Icu(kA)
cat B
Ics = 100% IcuIcw 6kA / 0,25s.
In = 400A
Anschluß oben
Befestigungsschraube derMotorabdeckung
Bezeichnungsschild
Verriegelung der AUS-Stellungfür Zylinderschlösser(Option für NS400/630)
Handgriff"Spannen von Hand"
Leistungsschild (siehe Seite 4)
Schaltstellungsanzeigeder Hauptkontakte (1)
Abschließvorrichtung der AUS-Stellungfür Vorhängeschlösser (siehe Seite 40)
Speicherzustandsmeldung"Speicher leer/gespannt" (2)
Schaltspielzähler(Option für NS400/630)
EIN-Taster (I/ON)
AUS-Taster (O/OFF)
Umschalten Hand/Auto (3)
manu/auto
chargedO OFF discharged O OFF
manu/auto
Ipush ONO
push OFF
manu/auto
dischargedO OFF I ONcharged discharged O OFF
O
push OFF
I
push ON
discharged
O OFF I ONcharged discharged
O OFF
ON OFF
(Verriegelung möglich)manuelle Rückstellung
(Verriegelung möglich)
or fault
fault
automatische Rückstellung
manuelle Rückstellung
Fehler-ursachesuchen
(9mal)
charged
discharged
Speicher gespannt
Speicher leer
Merlin Gerin6
Die Motorantriebe
Motorantrieb Typ T für C801 bis C1251 Der Motorantrieb ermöglicht fern-betätigtes Ein- und Ausschalten desLeistungsschalters mittels elek-trischer Befehle.Seine Position und seine geringen Ab-messungen beeintrŠchtigen den Zugriffauf und die Lesbarkeit der Einstel-lungen nicht. Er kann nach vorne ge-kippt werden, so da§ die AnschlŸsseund Zubehšrteile zugŠnglich sind (volt-metrische Auslšser u. Meldekontakte).
Das …ffnen der TŸr zum Umschaltenauf Hand-Betrieb :c bewirkt das Trennen des Strom-kreises .c ermšglicht das BetŠtigen des Kipp-hebels (aus- / einschalten).c ermšglicht das Abschlie§en desSchalters mit bis zu 3 VorhŠnge-schlšssern.
EIN-Stellung
I
E33
379
E33
380
Verriegelt mit 3 Vorhängeschlössern
E33
382
AUS-Stellung
II
OO
60 70 80 90 % Ir105
fault
O
E33
381
II
OO O
II
OO
5
STR 55UE
.63 .8
.5 1
xIn
Io
60 70 80 90 % Ir
t Ir
tr
Im
i
tm
Ih
th
105
test Ir Im
S
T
+ –
– +tr tm
.9.95
.8 1xIo
.85
15 48030
24060
at 1.5Ir
4
6
1.5 10xIr
.3
0 0.1
.3.2
82
3
.2
.1
Ic1
.4
.1
.3
on I2t offon I2t off
TFR
5
120
I5
8
2
3
4
6
.9.95
.8 1xIr
.85
A
B1015
88
C 801 N•HC 1001 N•H
LL
10C 1251N•H
12
B
A
th
Ih
.2 .6
.4
.5
.3
xIn
Ic1
I
fault
.4.3
.1
.2.2
test
xIn
O
I
MERLIN GERIN
C801Ui 750V. Uimp 8kV.Ue(V)
220/240
380/415
440
500/525
660/690
100
70
65
50
20
IEC 947-2UTE VDE BS CEIUNE NEMA
Icu(kA)
cat B
Ics = 100% Icu
In = 400A
Icw 6kA / 0,25s.
compact
Anschlu§ oben
Zylinderschlo§ zurVerriegelung desHebels
TŸr zur Umschaltung aufHandbetrieb
Leistungsschild
Verriegelung inAUS-Stellung
Hebel fŸrHandbetrieb
Auslšser(siehe Seite 11)
Anschlu§ unten
7Merlin Gerin
Leistungsschalter mit Drehantrieb
Leistungsschalter mit Drehantrieb direkt Der Drehantrieb direkt gewährleistet:c den Zugriff auf sowie die Lesbarkeitder Auslšsereinstellungen,c die eindeutige Stellungsanzeige(geeignet als Trennschalter),c die Anzeige der 3 Positionen AUS-EIN-Ausgelšst (0,I, tripped),c die Testauslšsung durch BetŠtigungder Taste "push to trip".
Varianten für Compact NS100...630 :es gibt Zubehšr fŸr folgende Anwen-dungen :c MCC-SchaltschrŠnke(Motor Control Center),c Bedienung von Werkzeugmaschinen.
Leistungsschalter mit Dreh-antrieb mit Türkupplung
E32
513
Der Drehantrieb mit Türkupplungbesteht aus :c einem an Stelle des Schalterdeckelsmontierten Drehantrieb (1),c einer Kupplungsachse (2),c einem an der TŸr befestigten Teile-satz (Handschalter und Schalter-deckel) (3).
Varianten :Teleskopachse fŸr Schalter inEinschubtechnik.Mit Ausnahme des Leistungsschildesund der Taste "push to trip" verschafftder Drehantrieb mit TŸrkupplung diegleichen Informationen als der Dreh-antrieb direkt; die Bedienung ist beibeiden AusfŸhrungen gleich.Bei geöffneter Tür ist der Zugriff auf dieAuslösereinstellungen, sowie derZugriff auf die Testtaste "push to trip"möglich.
Variante für Compact C801...C1251 :Sie besteht aus denselben Teilen wieder Drehantrieb mit TŸrkupplung, dieKupplungsachse ist jedoch nur in kur-zer AusfŸhrung lieferbar.
CAM (voreilende Hilfsschalter)c Voreilender Hilfsschalter beimAusschalten, benutzt in Vorauslšsungs-mechanismen.c Doppelter voreilender Hilfsschalterbeim Einschalten.Beide Hilfsschalter befinden sichsowohl bei dem Drehantrieb direkt alsauch bei dem Drehantrieb mit TŸr-kupplung in dem GehŠuse.
E32
514
ONI
OOFF ON
I
OOFF
1
2
3
E32
512
MERLIN GERINcompact
pushto
trip
reset
ON
I
OFFO
tripped
test
+
In=100A
ImIr
STR 22 SEIm
x Ir102
3
45 6
7
8
Ir
x Io1.8
.85
.88.9 .93
.95
.98
-
90105
alarm
Io
x In
.5.63
.7.8 .9
1
%Ir
tŽmoin de position appareil fermŽ
tŽmoin de position appareil ouvert
verrouillage de position par cadenas
tŽmoin de position appareil dŽclenchŽ
poignŽe de manÏuvre
plaque de firme (voir page 4)
bouton de dŽclenchement"push to trip"
raccordement aval
dŽclencheur (voir page 11)
raccordement amont
verrouillage de positionpar serrure (option)
identification du circuit
ON
I
OFFO
tripped
reset
Einschalten
Ausgelöst
I/ON(EIN)
O/OFF(AUS/getrennt)
Rückstellen
Merlin Gerin8
MN/MX
SD
OF1
OF2
OF3
SDE
Alle elektrischen Zubehšrteile sind ineinem vom Hauptstromkreis getrenntenTeil hinter der GerŠtefrontseite, bzw.hinter dem Motor- oder Drehantriebuntergebracht.Funktion und Anschlu§markierungensind direkt auf das SchaltergehŠuseeingeprŠgt.Hilfsschalter und Auslšser sind fŸr alleBemessungsstromgrš§en identisch.
Compact C801/1001/1251
Ein einziger gemeinschaftlicher Hilfs-schaltertyp erfŸllt alle Meldefunktionen(OF, SD, SDE, SDV).Die jeweilige Funktion wird durch diePlazierung im Leistungsschalterbestimmt.Die Hilfsschalter werden einfach imSchaltergehŠuse eingerastet.
Der Anschluß erfolgt über integrierteSchraubklemmen.
(1) Platz fŸr :c einen MITOP-Auslöser wenn der Leistungs-schalter mit einem elektronischen AuslšsesystembestŸckt ist;c einen Adapter, der benštigt wird, wenn derLeistungsschalter mit einem thermomagnetischenAuslšser und einem SDE-Schalter bestŸckt ist.(2) Platz fŸr Hilfsschalter fŸr die Optionen desAuslšsesystems STR53UE.
OF1 SD SDE OF2
MN/MX (1)
SDV
MN/MX
OFSD
Compact NS80
E32
515
E32
516
E32
517
E32
518
Elektrisches Zubehör
Compact NS100/160/250+ Vigi (Option)
OF1 OF2 SDSDE
MN/MX
OF3
MITOP
(2)
SDV
Compact NS400/630+ Vigi (Option)
9Merlin Gerin
Voltmetrische Auslšser werden fŸr dieFernauslšsung des Leistungsschalterseingesetzt (z.B. NOT-AUS-Schaltung).
Unterspannungsauslöser MNDieser Auslšser bewirkt die Auslšsungdes Compact NS-Schalters, wenn dieSpannung des Steuerstromkreisesunterhalb von 70% der Bemessungs-spannung abfŠllt.Das Einschalten des Leistungs-schalters kann erst wieder erfolgen,wenn die Spannung mindestens 85%des Bemessungswertes betrŠgt
Arbeitsstromauslöser MXDieser Auslšser bewirkt die Auslšsungdes Compact NS-Schalters, sobald dieSteuerspannung an den Klemmen 70%der Bemessungssteuerspannung er-reicht.
Voltmetrische Auslöser
Hilfsschalter ermšglichen die elek-trische Meldung der SchaltzustŠndedes Leistungsschalters.
Schalter OFZeigt die Stellung der Hauptkontaktedes Schalters an (AUS oder EIN).
Fehlermeldeschalter SDEElektrische Fehlermeldung.Meldet die Auslšsung des Schaltersdurch einen elektrischen Fehler:c †berlast,c Kurzschlu§,c vom Vigi-Block erfa§ter Isolations-fehler.
Schalter SDAusgelšst-Meldung.Dieser Hilfsschalter meldet dieAuslšsung des Leistungsschaltersdurch:c †berlast,c Kurzschlu§,
Hilfsschalter c Erdschlu§,c MX- oder MN-Auslšsung,c BetŠtigung der Auslšsetaste "push totrip",c Einsetzen oder Heranziehen einessteckbaren Schalters,c HandbetŠtigtes Ausschalten amMotorantrieb
Schalter SDVIsolationsfehlermeldung. Meldet dieAuslšsung des Schalters durch einenIsolationsfehler.
Schalter CAMHilfsschalter mit Voreilung beim …ffnenoder Schlie§en, der in den Drehantriebeingebaut wird.
Option COM (DatenŸbertragung).Erlaubt DatenŸbertragung im Dialpact-Modus.
Elektrisches Zubehör
E18
608
E18
609
fŸr NS100 bis NS630
fŸr C801 bis C1251
E23
839
Merlin Gerin10
11Merlin Gerin
Auslösereinstellungen
Auslösereinstellungen - Allgemeines
EinfŸhrung .............................................................................................. 12Compact NS100-160-250 A ................................................................... 14Compact NS400-630 A........................................................................... 15Compact C801-1001-1251 A .................................................................. 16
Auslösereinstellungen - Details
thermomagnetisch :TM16D bis TM250D ............................................................................... 17
elektronisch :STR22SE - STR22GE ............................................................................ 18STR23SE................................................................................................ 20STR53UE ............................................................................................... 21STR25DE et STR25DE (*) (Feineinstellung) .......................................... 24STR35SE/GE ......................................................................................... 26STR45AE................................................................................................ 27STR45BE................................................................................................ 28STR55UE ............................................................................................... 29
Erweiterte Einstellungen mit150 und 250 A Stromwandlern .................................................... 22
Anzeigen und Zubehör für die elektronischen AuslöserSTR22SE, STR23SE, STR53UE ........................................................... 23STR45AE/BE, STR55UE........................................................................ 30
Test elektronischer AuslösesystemeSTR22SE, STR23SE, STR53UE ........................................................... 31STR25DE, STR35DE/GE ....................................................................... 31STR45AE/BE, STR55UE........................................................................ 31
Einstellungen elektronischer Auslöser für denMotorschutz
STR22ME ............................................................................................... 32STR43ME ............................................................................................... 33STR35ME ............................................................................................... 34
Merlin Gerin12
ÜberlastschutzDie Auslšsezeit hŠngt von der Hšheder †berlast ab :c Die Auslšsung erfolgt innerhalb von 2Stunden bei einer †berlast von :v 120% Ir fŸr elektronische Auslšser,v 130% Ir fŸr thermomagnetischeAuslšser.c Bei einer †berlast von unter 105% Irlšst der Leistungsschalter nicht aus.
KurzschlußschutzDie Auslšsung erfolgt :c zeitverzšgert, sobald der eingestellteIm-Wert Ÿberschritten wird.c unverzšgert, sobald der eingestellteI-Wert Ÿberschritten wird.Die ME-Auslšsesysteme entsprechender IEC-Norm 947-4.1 (Motorschutz).
90 105 %IrSTR 53 UE >7560
(s) at 1.5 Ir on I2 t offImIr I
tr
tm
Im
x Ir101.5
2
34 5
6
8
00.1
.2.3 .3
.2
.1
tm(s)
Ir
x Io1.8
.85
.88.9 .93
.95
.98
15 24030
60120 240tr
Io
x In
1.5
.63 .8
-test
+
I
x In111.5
2
34 6
8
10
on I2 t off
Ih
x In1.2
.3
.4.5 .6
.7
.8
.1.1
.2
.3.4 .4
.3
.2
th(s)
T faulttest
µ P
> Ir
> Im
> Ih
STR 53 UEIr
x Io1.8
.85
.88.9 .93
.95
.98
60120 240tr
Io
x In
1.5
.63 .8
-+
90 105 %I>7560
Im
x Ir101.5
2
34 5
6
8
.2.3 .3
.2
ms)
I
x In111.5
2
34 6
8
10
c Compact-Leistungsschalterkšnnen au§erdem mit einem Vigi-Block(Erdschlu§schutz) ausgerŸstet werden,der die Auslšsung des Schalters beiErfassen eines Isolationsfehlers bewirkt(Fehlerstrom der zu Stromschlag oderBrand fŸhren kann).
Alle Compact-Auslšsesysteme fŸr dieGerŠtegrš§en NS100 bis NS630verfŸgen Ÿber die Reflex-Auslšse-technik, eine exklusive Entwicklung vonMerlin Gerin. Sie gewŠhrleistet volleSelektivitŠt, sogar bei starken Kurz-schlŸssen.
Ein Auslšsesystem Ÿberwacht dendurch den Leistungsschalter flie§endenStrom und bewirkt die Auslšsung desSchalters im Fehlerfalle.c Thermomagnetische undelektronische Auslösesystemeerfassen †berlast und Kurzschlu§;
E32
521
Auslösereinstellungen - Allgemeines
13Merlin Gerin
Terminologie der Überlast- und Kurzschlußschutzeinstellungen
E31
303
Langzeitverzögerter ÜberlastschutzIo = Grobeinstellung (Funktion
von In)Ir = Feineinstellung
tr = Langzeitverzšgerung,fest oder einstellbar, je nachAuslšsertyp
Kurzzeitverzögerter SchutzIm = kurzzeitverzšgerter
Kurzschlu§schutz, I2t-Kurve inON oder OFF-Stellung, jenach Auslšsertyp
tm = Kurzzeitverzšgerung,fest oder einstellbar,
Unverzögerter Schutz II = Unverzšgerter Kurzschlu§-
schutz, fest oder einstellbar,je nach Auslšsertyp
Ic1 = Einstellbare Last-Ÿberwachung fŸr STR45,STR53 und STR55
Ic2 = Einstellbare Last-Ÿberwachung fŸr STR45 undSTR55
ErdschlußschutzIh = Erdschlu§schutz,
I2t-Kurve in ON oder OFF-Stellung
th = AuslšseverzšgerungErdschlu§
7
82
1
3
5
4
6
Io x Ir
6
tr
Im
tmON
OFF
I
Ic1
7
8
Ih
th
2 fest auf : TM16D bis 250D STR22SE / 22GE / 22ME, STR23SE, STR25DE, STR35SE / GE / ME
einstellbar auf : STR43ME, STR53UE, STR45AE / BE, STR55UE
Ic2
6
fest auf : TM16D bis 250D STR22SE / GE / ME, STR23SE, STR25DE / GE
einstellbar auf : STR45AE / BE4 STR35SE / GE, STR43ME, STR53UE, STR55UE
5 fest auf : STR22SE / GE / ME, STR23SE / GE, STR35SE / GE / ME, STR43ME
einstellbar auf : STR53UE, STR55UE
3 fest auf : TM16D ≤ 160 / TM16G bis TM63G, STR22ME
einstellbar auf allen anderen Typen
OFF
ON
1 einstellbar auf allen Typen
Merlin Gerin14
Auslösereinstellungen - Allgemeines
für Compact NS100-160-250AZwei austauschbare Produktreihen
Thermomagnetische Auslöser
E32
522
Elektronische Auslöser TypkennzeichnungSTR 22 SE
E32
523
AusführungD : Standard-AusfŸhrungG : AusfŸhrung mit niedrigem Ansprech-
wert
Bemessungsstrom
BaureiheTM = thermomagnetischMA = magnetisch
TypkennzeichnungTM 250 D
E : IECP : UL
AusführungS : selektives AuslšsesystemG : AusfŸhrung fŸr den GeneratorschutzM : AusfŸhrung fŸr den Motorschutz
Baugröße2 : NS100/160/250
Anzahl Einstellungen
BaureiheSTR = elektronisch
O
pushto
trip
O
440500/525660/690250
65501085
cat AIcs = 100% Icu
IEC 947.2UTE VDE BS CEI UNE NEMA
200/250A
Ir
x In ImIr
In=160A Im
x Ir
90105 %Ir STR 22 SE
50/60Hzalarmtest
1.63.7
.8.85 .9
.95
.98101.5
2
34 5
6
8
ImIr
x 250A x 250A
1 .8.9
9
8 7
6
10 5
ImIr
TM 250 D250A / 40°C
Mindest-/Hšchstwert desthermischen Schutzes
GerŠteidentifizierung
Bemessungsstrom undUmgebungstemperatur
Ansprechwert des magnetischenAuslšsers (Kurzschlu§schutz)
Ansprechwert des thermischenAuslšsers (†berlastschutz)
O
pushto
trip
O
440500/525660/690250
65501085
cat AIcs = 100% Icu
IEC 947.2UTE VDE BS CEI UNE NEMA
Ir
x In ImIr
In=160A Im
x Ir
90105 %Ir STR 22 SE
50/60Hzalarmtest
1.63.7
.8.85 .9
.95
.98101.5
2
34 5
6
8
40/100
test
+
In=100A
ImIr
STR 22 SEIm
x Ir102
3
45 6
7
8
Ir
x Io1.8
.85
.88.9 .93
.95
.98
-
90105
alarm
Io
x In
.5.63
.7.8 .9
1
%Ir
GerŠteidentifizierung
KurzzeitverzšgerterKurzschlu§schutz (Im)
Teststecker (siehe Seite 31)
Lastanzeige/Vorwarnung(siehe Seite 23)
Langzeitverzšgerter†berlastschutz Io x Ir (LR)Io : GrobeinstellungIr : Feineinstellung
Bemessungsstrom des Auslšsers(Berechnungsgrundlage fŸr dieEinstellungen)
15Merlin Gerin
für Compact NS400-630 AElektronischer Auslöser STR53UE
E32
531
TypkennzeichnungSTR 53 UE
E : IECP : UL
AusführungS : selektives AuslšsesystemU : universelles AuslšsesystemM : AusfŸhrung fŸr den Motorschutz
Baugröße3 : NS400/630
Anzahl Einstellungen
BaureiheSTR = elektronisch
pushto
trip160/400A160/400A
90 105 %IrSTR 53 UE >7560 T
ImIr I
tr
tm
Im
x Ir101.5
2
34 5
6
8
Ir
x Io1.8
.85
.88.9 .93
.95
.98
test
+
I
x In111.5
2
34 6
8
10
Ih
x In1.2
.3
.4.5 .6
.7
.8
Io
x In
1.5
.63 .8
(s) at 1.5 Ir240
30
60120 240tr
00.1
.2.3 .3
.2
.1
tm(s)
on I2 t off on I2 t off.1.1
.2
.3.4 .4
.3
.2
th(s)
faulttest
µ P
> Ir
> Im
> Ih
GerŠteidentifizierung
Lastanzeige/Vorwarnung (siehe Seite 23)
KurzzeitverzšgerterKurzschlu§schutz (Im)
Einstellung des unverzšgertenKurzschlu§schutzes (I)
Platz fŸr die Option SD"Fehlermeldung"
Langzeitverzšgerter†berlastschutz (LR)Io : GrobeinstellungIr : Feineinstellung
Platz fŸr die Option "Erdschlußschutz"oder "Lastüberwachung"
Kurzzeitverzšgerung (tm)
Langzeitverzšgerung (tr)
Teststecker (siehe Seite 31)
Merlin Gerin16
für C801-1001-1251 Anur elektronisch
E32
868
Auslösereinstellungen - Allgemeines
NormE : IECP : UL
AusführungI : TrennerD : VerteilerS : selektivG : GeneratorschutzM : MotorschutzU : universellB : selim
Leistungsschalter5 : C801/1001/1251
Anzahl Einstellungen
BaureiheSTR = elektronisch
TypkennzeichnungSTR 5 5 U E
OO
5
STR 55UE
.63 .8
.5 1
xIn
Io
60 70 80 90 % Ir
t Ir
tr
Im
i
tm
Ih
th
105
test Ir Im
S
T
+ –
– +tr tm
.9.95
.8 1xIo
.85
15 48030
24060
at 1.5Ir
4
6
1.5 10xIr
.3
0 0.1
.3.2
82
3
.2
.1
Ic1
.4
.1
.3
on I2t offon I2t off
TFR
5
120
I5
8
2
3
4
6
.9.95
.8 1xIr
.85
A
B1015
88
C 801 N•HC 1001 N•H
LL
10C 1251N•H
12
B
A
th
Ih
.2 .6
.4
.5
.3
xIn
Ic1
I
fault
.4.3
.1
.2.2
test
xIn
GerŠteidentifizierung
Lastanzeige/Vorwarnung(siehe Seite 30)
Langzeitverzšgerter†berlastschutz (LR)Io : GrobeinstellungIr : Feineinstellung
KurzzeitverzšgerterKurzschlu§schutz (Im)
Einstellung desunverzšgertenKurzschlu§schutzes (I)
Einstellung des Ansprech-wertes fŸr den Erdschlu§-schutz (Ih)
Einstellung der Zeit-verzšgerung fŸr denErdschlu§schutz (th)
LastŸberwachung
Kurzzeitverzšgerung (tm)
Langzeitverzšgerung (tr)
Teststecker (siehe Seite 31)
17Merlin Gerin
Einstellungen der Thermo-magnetischen AuslöserTM16D bis TM250D
1 3
ImIr
x 250A x 250A
1 .8.9
9
8 7
6
10 5
ImIr
TM 250 D250A / 40°C
I
t
0
1
3
Ir Im
ImIr
x 250 A
1.9
.8
x 250 A
9
8 7
6
10 5
E33
456
E32
524
Ir Im
x 250 A
9
8 7
6
10 5
x 250 A
1.9
.8
E32
525
Überlastschutz (thermische Auslösung)
Bemessungsstrom des Auslösers (A)16 25 40 63 80 100 125 160 200 250
0.8 12.8 20 32 50.4 64 80 100 128 160 2000.9 14.4 22.5 36 56.7 72 90 112.5 144 180 2251 16 25 40 63 80 100 125 160 200 250
Ir = 250 A x 0.9 = 225 A
Kurzschlußschutz (magnetische Auslösung)
Bemessungsstrom des Auslösers (A)16 25 40 63 80 100 125 160 200 250
5 1000 12506 1200 15007 1400 17508 1600 20009 1800 225010 2000 2500
fest
Einstellung
Im = 250 A x 8 = 2000 A Die Auslšsung erfolgt unverzšgert,sobald der Strom > 2000 A.
Einstellung
Merlin Gerin18
Einstellungen der ElektronischenAuslöser STR22SE und STR22GE
E32
563
test
+
In=100A
1
ImIr
STR 22 SE
Im
x Ir
102
3
45 6
7
8
Ir
x Io
1.8.85
.88.9 .93
.95
.98
-
90105
alarm
Io
x In
.5.63
.7.8 .9
1
3
I
t
0
1
3
Ir Im
%Ir
Elektronischer Auslöser STR22SE, Bemessungsstrom 40, 100, 160, 250 A
Im
x Ir
Ir
x Io
Io
x In1.8
.85
.88.9 .93
.95
.98102
3
45 6
7
8.5
.63
.7.8 .9
1
E32
526
Langzeitverzögerter Überlastschutz
STR22SE 40 A Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 16 17 17,5 18 185 19 19,5 200.63 20 21 22 22,5 23 23,5 24,5 250.7 22,5 24 24,5 25 26 25,5 27,5 280.8 25,5 27 28 29 29,5 30 31 320.9 29 30,5 31,5 32 33,5 34 35 361 32 34 35 36 37 38 39 40
STR22SE 100 A Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 40 42,5 44 45 46,5 47,5 49 500.63 50,5 53,5 55,5 57 59 60 62 630.7 56 59,5 61,5 63 65 66,5 68,5 700.8 64 68 70,5 72 74,5 76 78,5 800.9 72 76,5 79 81 83,5 85,5 88 901 80 85 88 90 93 95 98 100
STR22SE 160 A Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 64 68 70,5 72 74,5 76 78,5 800.63 81 86 89 91 94 96 99 1010.7 89,5 95 98,5 101 104 106,5 110 1120.8 102,5 109 112,2 115 119 121,5 125,5 1280.9 115 122,5 127 129,5 134 137 141 1441 128 136 141 144 149 152 157 160
19Merlin Gerin
STR22SE 250 A Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 100 106 110 112,5 116 119 122,5 1250.63 126 134 138,5 142 146,5 150 154 157,50.7 140 149 154 157,5 163 166 171,5 1750.8 160 170 176 180 186 190 196 2000.9 180 191 198 202,5 209 214 220,5 2251 200 212,5 220 225 232,5 237,5 245 250
Io
Ir = 128 A x 0.9 = 115 A
Ir
0.5 0.63 0.7 0.8 0.9 1
0.8 0.850.88 0.9 0.930.950.98 1
160 AIn
Grobeinstellung 128 A
z.B. :
z.B. :
2 3 4 5 6 8 10
Ir
Ir = 128 A x 0.9 = 115 A
Im = 115 A x 5 = 575 A
Im
160 A
7
0.5 0.63 0.7 0.8 0.9 1
0.8 0.850.88 0.9 0.930.950.98 1
In
Io
Im
x Ir
Ir
x Io
Io
x In1.8
.85
.88.9 .93
.95
.98102
3
45 6
7
8.5
.63
.7.8 .9
1
E32
527 Bei einem elektronischen Auslšser
hŠngt der Ansprechwert des kurz-zeitverzšgerten Kurzschlu§schutzesvon der Einstellung des langzeit-verzšgerten Schutzes ab.
Die Auslšsung erfolgt unvezšgert,sobald der Strom > 575 A.
Kurzzeitverzögerter Kurzschluß-schutz
Merlin Gerin20
Einstellungen des elektronischenAuslösers STR23SE
I
t
0
1
3
Ir Im
ImIr
STR 23 SE
Ir
x Io
Io
-test
+
90105 %Iralarm
x In
1 3
.5
.63.7
.91
.8.85
.9.95
1
.88.93
.98
.8
234
5 678
10
Im
x Ir
E32
565
Der Bemessungsstrom der Auslöser STR23SE und STR53UE wird vomStromwandler des Leistungsschalters bestimmt.
.5.63
.78 9
1
Im
x Ir
Ir
x Io
Io
x In1.8
.85
.88.9 .93
.95
.98102
3
45 6
7
8
E32
529
Compact NS630 Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 252 268 277 284 293 299 309 3150.63 318 337 349 357 369 377 389 3970.7 352 374 388 396 410 418 432 4410.8 403 428 443 472 469 479 494 5040.9 453 481 498 510 527 538 555 5671 504 535 554 567 586 598 617 630
Langzeitverzögerter Überlastschutz
Compact NS400 Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 160 170 176 180 186 190 196 2000.63 202 214 222 227 234 239 247 2520.7 224 238 246 252 260 256 274 2800.8 256 272 282 300 298 304 314 3200.9 288 306 316 324 334 342 352 3601 320 340 352 360 372 380 392 400
Ir
Io
In
0.8 0.850.88 0.9 0.930.950.98 1
0.63 0.7 0.8 0.90.5 1
Ir = 320 A x 0.93 = 298 AIr = 320 A x 0.93 = 298 A
400 A
Grobeinstellung 320 A
Einstellung der Schutzfunktionen(Beispiel)
.5.63
.78 9
1
Im
x Ir
Ir
x Io
Io
x In1.8
.85
.88.9 .93
.95
.98102
3
45 6
7
8
E32
530 Kurzzeitverzögerter Kurzschluß-
schutzDer Ansprechwert des kurzzeit-verzšgerten Schutzes hŠngt von derEinstellung des langzeitverzšgertenSchutzes ab.
z.B. :
z.B. :
Io
Ir = 320 A x 0.93 = 298 A
Ir
Ir = 320 A x 0.93 = 298 A
Im
In 400 A
0.63 0.7 0.8 0.90.5 1
0.8 0.850.88 0.9 0.930.950.98 1
2 3 4 5 6 7 8 10
Im = 298 A x 7 = 2086 A
Bei einem NS400-Schalter mit 400 A-Strom-wandler ist der Bemessungsstrom des STR23SEauf 400 A eingestellt.
21Merlin Gerin
Einstellungen des elektronischenAuslösers STR53UE
E32
567
E32
532
90 105 %IrSTR 53 UE >7560
(s) at 1.5 Ir on I2 t offImIr I
tr
tm
Im
x Ir101.5
2
34 5
6
8
00.1
.2.3 .3
.2
.1
tm(s)
Ir
x Io1.8
.85
.88.9 .93
.95
.98
15 24030
60120 240tr
Io
x In
1.5
.63 .8
-test
+
I
x In111.5
2
34 6
8
10
on I2 t off
Ih
x In1.2
.3
.4.5 .6
.7
.8
.1.1
.2
.3.4 .4
.3
.2
th(s)
T faulttest
µ P
> Ir
> Im
> Ih
318 2 4 5 67
2
4
5
Ir Im
3
I I
t
0
1
Compact NS630 Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 252 268 277 284 293 299 309 3150.63 318 337 349 357 369 377 389 3970.8 403 428 443 472 469 479 494 5041 504 535 554 567 586 598 617 630
Der STR53UE-Auslšser ermšglichteine noch feinere Abstimmungzwischen Betriebssicherheit undBetriebskontinuitŠt fŸr spezifische An-wendungen, wie z.B. Induktionsšfen,Leuchtstofflampen, Lichtbogenschwei§-maschinen, Halbleiter-Regelsysteme,etc...
Kurzzeitverzögerung
E33
465
Langzeitverzögerung
E33
478
0...0,3 stm
I2t off tm
on I2t
0...0,3 s
4
tr 15...240 s
2
Langzeitverzögerter Überlastschutz
Compact NS400 Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 160 170 176 180 186 190 196 2000.63 202 214 222 227 234 239 247 2520.8 256 272 282 300 298 304 314 3201 320 340 352 360 372 380 392 400
AuslösereinstellungenSTR53UE
Im
x Ir
101.5
2
34 5
6
8
Ir
x Io
1.8.85
.88.9 .93
.95
.98
I
x In
111.5
2
34 6
8
10
x In
Io
1.5
.63 .8
Die Auslšsung erfolgt schneller alsbeim kurzzeitverzšgerten Kurzschlu§-schutz. Der Ansprechwert hŠngt vomBemessungsstrom des Schalters undder Einstellung ab.
Schutz gegen große Kurzschluß-ströme mit dem unverzögertenKurzschlußauslösesystem, I
1.5 2 3 4 6 8 10 11
I = 400 A x 6 = 2400 A
400 Az.B. :
I
In
Optionen : siehe Seite 23.
Der STR53UE verfŸgt Ÿber 3 zusŠtz-liche Einstellungen :c Unverzšgerte Kurzschlu§stromaus-lšsung (I),c Langzeitverzšgerung (tr),c Kurzzeitverzšgerung (tm).
Merlin Gerin22
Erweiterte Einstellungenmit 150 und 250 A Stromwandlern
Langzeitverzögerter Überlastschutz
NS400 (150 A) Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 60 63,76 66 67,5 69,75 71,25 73,5 750.63 75,6 80,32 83,16 85,05 87,88 89,77 92,61 94,50.7 84 89,25 92,4 94,5 97,65 99,75 102,9 1050.8 96 102 105,6 138 111,5 114 117,6 1200.9 108 114,75 118,8 121,5 125,55 128,55 132,5 1351 120 127,5 132 135 139,5 142,5 147 150
AuslösereinstellungSTR23SE
NS400 (250 A) Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 100 106,25 110 112,5 116,25 118,75 122,5 1250.63 126 133,87 138,6 141,75 146,57 149,62 154,35 157,60.7 140 148,75 154 157,5 162,75 166,25 171,5 1750.8 160 170 176 180 185 190 196 2000.9 180 191,25 198 202,5 209,25 213,75 220,5 2251 200 212,2 220 225 232,5 237,5 245 250
Langzeitverzögerter Überlastschutz
NS400 (150 A) Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 60 63,76 66 67,5 69,75 71,25 73,5 750.63 75,6 80,32 83,16 85,05 87,88 89,77 92,61 94,50.8 96 102 105,6 138 111,5 114 117,6 1201 120 127,5 132 135 139,5 142,5 147 150
AuslösereinstellungSTR53UE
NS400 (250 A) Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 100 106,25 110 112,5 116,25 118,75 122,5 1250.63 126 133,87 138,6 141,75 146,57 149,62 154,35 157,60.8 160 170 176 180 185 190 196 2001 200 212,2 220 225 232,5 237,5 245 250
23Merlin Gerin
Anzeigen und Zubehör für die elektronischenAuslöser STR22SE, STR23SE, STR53UE
LastanzeigenAlarm-LED
Für Compact NS100/160/250:STR22SE oder STR23SEDie LED leuchtet, wenn die Last 90%des Ansprechwertes Ir. Ÿbersteigt.
90 105 %IrSTR 53 UE >7560 90 105 %Ir>7560
Für Compact NS400/630 : STR53UEDie 4 LEDs zeigen die Last in % an:c 60 / 75 / 90 % : Die Last ist hoch. Esist darauf zu achten, da§ der Ansprech-wert von 105% nicht erreicht wird;
E32
533
E32
534
Die LED blinkt, wenn die Last 105 %des Ansprechwertes Ir Ÿbersteigt unddie Auslšsung des Leistungsschaltersunmittelbar bevorsteht.
c 105 % : Es liegt †berlast vor undeine Auslšsung steht bevor.Reduzieren Sie die Last, indem Sieminder wichtige Verbraucher ab-schalten.
90105 %IrSTR 23 SE alarm90105alarm %Ir
Option F, FehlermeldungDiese Option kann in den GerŠtenSTR53UE installiert werden(Compact NS400 oder NS630).Nach einer Auslšsung ist die Fehler-test-Taste zu betŠtigen, damit die
genaue Fehlerursache angezeigt wird:c µP : interner Prozessorfehler,c > Ir : †berlast (langzeitverzšgerterSchutz) oder †bertemperatur desLeistungsschalters,c > Im : Kurzschlu§ (kurzzeit-verzšgerter oder unverzšgerterSchutz),c > Ih : Erdschlu§.
Optionen für STR53UE
1.8
.85
.88.9 .93
.95
.98
R
Ic
E26
030
E32
693
0,8...1 IrIc16
Io
Ir = 320 A x 0.93 = 298 A
Ir
Ir = 320 A x 0.93 = 298 A
Ic
In 400 A
0.63 0.80.5 1
0.8 0.850.88 0.9 0.930.950.98 1
Ic = 298 A x 0.95 = 283 A
0.8 0.850.88 0.9 0.93 0.95 0.98 1
1
Grobeinstellung 320 A
Einstellung des Ansprechwertes(Beispiel) :
0,2...1 InIh
0,1...0,4 sON I2t
th
7
8
E32
691
th
0,1...0,4 sI2t OFF
Ih 0,2...1 In
7
8
E32
692
Erdschlußschutz - Option TDer Auslšser kann mit Option T fŸr denErdschlu§schutz in TN-S-Netzen aus-gerŸstet werden.
Lastüberwachung - Option RDiese Option zeigt extern an, ob dieLast unter oder Ÿber dem AnsprechwertIc liegt.
E26
031
faulttest
µ P
> Ir
> Im
> Ih
Einstellung derAuslšseverzšgerung
Einstellung desAnsprechwertesIh = 0,2...1 x In
E26
029
on I2 t off
Ih
x In1.2
.3
.4.5 .6
.7
.8
.1.1
.2
.3.4 .4
.3
.2
th (s)
T
Sie wird meistens eingesetzt, um imFalle einer †berlast einen minder wich-tigen Verbraucher abzuschalten (Last-abwurf).
Merlin Gerin24
Einstellungen des elektronischenAuslösers STR25DE
3
1
Ir I I
t
0
5
STR 25DE 60 70 80 90 % Ir
t Ir
I
i
105
test Ir I
+ –
.9.95
.8 1xIo
.85
4
6
1.5 10xIr
82
3
5
1 3
E32
679
Einstellung STR25DE
Compact C801N/H/L In = 800 A
Einstellung 1 0.95 0.9 0.8 0.7 0.63 0.5 0,4
Ir (A) 800 760 720 640 560 504 400 320Compact C1001N/H/L In = 1000 A
Einstellung 1 0.95 0.9 0.8 0.7 0.63 0.5 0,4
Ir (A) 1000 950 900 800 700 630 500 400Compact C1251N/H/L In = 1250 A
Einstellung 1 0.95 0.9 0.8 0.7 0.63 0.5 0,4
Ir (A) 1250 1187 1125 1000 875 787 625 500
1
1
1
I
x Ir
Ir
x Io101.5
2
34 5
6
81.8
.85
.9.95
E33
457
Beispiel :In = 1000 A,Ir = 800 AIm = 4000 A
In
Ir
Ir = 0,8 x 1000 = 800 A
Im
1000 A
0.4 0.5 0.63 0.8 0.9 0.95 1
Im = 5 x Ir = 4000 A
1
1.5 2 3 4 5 6 8 103
Ir
x Io1.8
.85
.9.95
I
x Ir101.5
2
463
5
8
E33
458
25Merlin Gerin
Io
Ir = 800 x 0,9 = 720 A
Im
1000 A
0.5 0.63 0.8 1
Im = 720 x 5 = 3600 A
1
1.5 2 3 4 5 6 8 103
0.8 0.850.875 0.9 0.925 0.95 0.975 1Ir2
In
E32
680
5
STR 25DE (*)
.63 .8
.5 1
xIn
Io
60 70 80 90 % Ir
t Ir
I
i
105
test Ir I
+ –
.9.95
.8 1xIo
.85
4
6
1.5 10xIr
82
3
5
11 3
3
1
Ir I I
t
0(*) Feineinstellung
Einstellungen des elektronischenAuslösers STR25DE(*) (Feineinstellung)
Io Ir
1
Io Ir
Io Ir
Einstellung STR25DE (*)
Compact C801N/H/L In = 800 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 400 390 380 370 360 350 340 3200,63 504 491 479 466 454 441 428 4030,8 640 624 608 592 576 560 544 5121 800 780 760 740 720 700 680 640
Compact C1001N/H/L In = 1000 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 500 488 475 463 450 438 425 4000,63 630 614 599 583 567 551 536 5040,8 800 780 760 740 720 700 680 6401 1000 975 950 925 900 875 850 800
Compact C1251N/H/L In = 1250 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 625 609 594 578 563 547 531 5000,63 788 768 748 728 709 689 669 6300,8 1000 975 950 925 900 875 850 8001 1250 1219 1188 1156 1125 1094 1063 1000
1
1
x Irx Iox In1.8
.5
.63
1
Io.8
Ir
.85
.9.95
I
101.5
2
34 5
6
8
E33
459
Beispiel :C1001N : In = 1000 A,
Ir = 720 A,Im = 3600 A,
Grobeinstellung 800 A
E33
460
x Io
Ir
1.8
.85
.9.95
x Ir
I
2
46
8
53
1.5 10
x In
.5
.63
1
Io.8
Merlin Gerin26
Io
Ir = 800 x 0,9 = 720 A
Im
1000 A
0.5 0.63 0.8 1
Im = 720 x 5 = 3600 A
1
1.5 2 3 4 5 6 8 103
0.8 0.850.875 0.9 0.925 0.95 0.975 1Ir2
In
Einstellungen des elektronischenAuslösers STR35SE/GE
E32
681
15 8
C 801 N•HC 1001 N•H
LL
12C 1251N•H
t
i
Ir
Im
tm
I
120s
A
A1,5 Ir
x In
5
STR 35SE
.63 .8
.5 1
xIn
Io
60 70 80 90 % Ir105
test Ir Im
+ –
tm
.9.95
.8 1.85
4
6
1.5 10xIr
.3
0 0.1
.3.2
82
3
.2
.1
on I2t off
5
1
xIo
1 3 4
Ir Im I I
t
0
4
Ir
Im
1
0,4...1In
1,5...10Ir
3
Grobeinstellung 800 A
x Io
Ir
1.8
.85
.9.95
x Ir
Im
2
46
8
53
1.5 10
x In
.5
.63
1
Io.8
Beispiel :C1001N : In = 1000 A,
Ir = 720 A,Im = 3600 A,
Kurzzeitverzögerung
0...0,3 stm
I2t off tm
on I2t
0...0,3 s
4
C801 N/H LC1001N/H L C1251N/H
A 10 8 10B 15 8 12
E32
690
E33
462
Einstellung STR35SE/GE
Compact C801N/H/L In = 800 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 400 390 380 370 360 350 340 3200,63 504 491 479 466 454 441 428 4030,8 640 624 608 592 576 560 544 5121 800 780 760 740 720 700 680 640
Compact C1001N/H/L In = 1000 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 500 488 475 463 450 438 425 4000,63 630 614 599 583 567 551 536 5040,8 800 780 760 740 720 700 680 6401 1000 975 950 925 900 875 850 800
Compact C1251N/H/L In = 1250 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 625 609 594 578 563 547 531 5000,63 788 768 748 728 709 689 669 6300,8 1000 975 950 925 900 875 850 8001 1250 1219 1188 1156 1125 1094 1063 1000
Io Ir
1Io Ir
Io Ir
1
1
x Irx Iox In1.8
.5
.63
1
Io.8
Ir
.85
.9.95
Im
101.5
2
34 5
6
8
E33
461
27Merlin Gerin
Io
Ir = 800 x 0,9 = 720 A
Im
1000 A
0.5 0.63 0.8 1
Im = 720 x 5 = 3600 A
1
1.5 2 3 4 5 6 8 103
0.8 0.850.875 0.9 0.925 0.95 0.975 1Ir2
In
E32
682
5
STR 45AE
.63 .8
.5 1
xIn
Io
90 % Ir
t Ir
tr
Im
i
tm
Ih
th
105
test Ir Im
S
T
+ –
– +tr tm
.9.95
.8 1xIo
.85
15 48030
24060
at 1.5Ir
4
6
1.5 10xIr
.3
0 0.1
.3.2
82
3
.2
.1
Ic1
.4
.1
.3
on I2t offon I2t off
TFR
5
120 .9.95
.8 1xIr
.85
60 70 80
th
Ih
.2 .6
.4
.5
.3
xIn
A 20
C 801N•H
Ic1
x In 23
C 1001N•H
18
C 1251N•H
A
I
.2.1
.2
.3
.4
fault
31 421
Ir Im I I
t
0
4
2
Ir
Im
10,4...1In
1,5...10Ir3
Einstellungen des elektronischenAuslösers STR45AE
x Io
Ir
1.8
.85
.9.95
x Ir
Im
2
46
8
53
1.5 10
x In
.5
.63
1
Io.8
Beispiel :C1001N : In = 1000 A,
Ir = 720 A,Im = 3600 A,
Grobeinstellung 800 A
E33
462
Io Ir
Io Ir
Io Ir
Einstellung STR45AE
Compact C801N/H/L In = 800 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 400 390 380 370 360 350 340 3200,63 504 491 479 466 454 441 428 4030,8 640 624 608 592 576 560 544 5121 800 780 760 740 720 700 680 640
Compact C1001N/H/L In = 1000 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 500 488 475 463 450 438 425 4000,63 630 614 599 583 567 551 536 5040,8 800 780 760 740 720 700 680 6401 1000 975 950 925 900 875 850 800
Compact C1251N/H/L In = 1250 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 625 609 594 578 563 547 531 5000,63 788 768 748 728 709 689 669 6300,8 1000 975 950 925 900 875 850 8001 1250 1219 1188 1156 1125 1094 1063 1000
1
1
1
x Irx Iox In1.8
.5
.63
1
Io.8
Ir
.85
.9.95
Im
101.5
2
34 5
6
8
E33
461
Kurzzeitverzögerung
0...0,3 stm
I2t off tm
on I2t
0...0,3 s
4E33
465
Langzeitverzögerung
E32
689
tr 15...480 s
2
Optionen : siehe Seite 30
Merlin Gerin28
Io
Ir = 800 x 0,9 = 720 A
Im
1000 A
0.5 0.63 0.8 1
Im = 720 x 5 = 3600 A
1
1.5 2 3 4 5 6 8 103
0.8 0.850.875 0.9 0.925 0.95 0.975 1Ir2
In
E32
683
Einstellungen des elektronischenAuslösers STR45BE
Io Ir
Io Ir
Io Ir
Einstellung STR45BE
Compact C801N/H/L In = 800 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 400 390 380 370 360 350 340 3200,63 504 491 479 466 454 441 428 4030,8 640 624 608 592 576 560 544 5121 800 780 760 740 720 700 680 640
Compact C1001N/H/L In = 1000 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 500 488 475 463 450 438 425 4000,63 630 614 599 583 567 551 536 5040,8 800 780 760 740 720 700 680 6401 1000 975 950 925 900 875 850 800
Compact C1251N/H/L In = 1250 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 625 609 594 578 563 547 531 5000,63 788 768 748 728 709 689 669 6300,8 1000 975 950 925 900 875 850 8001 1250 1219 1188 1156 1125 1094 1063 1000
1
1
1
x Irx Iox In1.8
.5
.63
1
Io.8
Ir
.85
.9.95
Im
101.5
2
34 5
6
8
x Io
Ir
1.8
.85
.9.95
x Ir
Im
2
46
8
53
1.5 10
x In
.5
.63
1
Io.8
Beispiel :C1001N : In = 1000 A,
Ir = 720 A,Im = 3600 A,
Grobeinstellung 800 A
E33
462
E33
461
5
STR 45BE
.63 .8
.5 1
xIn
Io
60 70 80 90 % Ir
t Ir
tr
Im
i
tm
Ih
th
105
test Ir Im Ih
S
T
+ –
– +tr tm th
.9.95
.8 1xIo
.85
120
15 48030
24060
at 1.5Ir
4
6
1.5 10xIr
.3
0 0.1
.3.2
82
3
.2
.1
.2 .6xIn
.4
.1 .1.2
.4.3
.4
.5
.3
.3
.2
on I2t offon I2t off
T
5
1 12 43
2
Ir Im I
t
0
4
Ir
Im
10,4...1In
1,5...10Ir3
Kurzzeitverzögerung
0...0,3 stm
I2t off
tm
on I2t
0...0,3 s
4E33
466
tr 15...480 s
2
Langzeitverzögerung
E33
479
Zubehör : siehe Seite 30
29Merlin Gerin
Io
Ir = 800 x 0,9 = 720 A
Im
1000 A
0.5 0.63 0.8 1
Im = 720 x 5 = 3600 A
1
1.5 2 3 4 5 6 8 103
0.8 0.850.875 0.9 0.925 0.95 0.975 1Ir
In
I = 6 x In = 6000 A
I 2 3 4 5 6 8 A B5
E32
684
5
STR 55UE
.63 .8
.5 1
xIn
Io
60 70 80 90 % Ir
t Ir
tr
Im
i
tm
Ih
th
105
test Ir Im
S
T
+ –
– +tr tm
.9.95
.8 1xIo
.85
15 48030
24060
at 1.5Ir
4
6
1.5 10xIr
.3
0 0.1
.3.2
82
3
.2
.1
Ic1
.4
.1
.3
on I2t offon I2t off
TFR
5
120
I5
8
2
3
4
6
.9.95
.8 1xIr
.85
A
B1015
88
C 801 N•HC 1001 N•H
LL
10C 1251N•H
12
B
A
th
Ih
.2 .6
.4
.5
.3
xIn
Ic1
I
fault
.4.3
.1
.2.2
test
xIn
3 51 421
Ir Im I I
t
0
4
2
Ir
Im
0,4...1In
1,5...10Ir
I 2...A/B x In
1
3
5
Einstellungen des elektronischenAuslösers STR55UE
Io Ir
Io Ir
Io Ir
1
1
1
x Irx Iox In
Io Ir Im
.5
.63
1
.8
101.5
2
34 5
6
8
1.8.85
.9.95
2
3
45 6
8
I
x In
A
B
E33
463
Langzeitverzögerung
E32
689
tr 15...480 s
2
Beispiel :C1001N : In = 1000 A,
Ir = 720 A,Im = 3600 A,I = 6000 A Grobeinstellung 800 A
x Irx Iox In
Io Ir Im
1.8
.85
.9.95
I
x In
.5
.63
1
.8
2
46
5
8
3
1.5 10 B
A3
58
64
2
E33
464
Kurzzeitverzögerung
0...0,3 stm
I2t off tm
on I2t
0...0,3 s
4
C801 N/H LC1001N/H L C1251N/H
A 10 8 10B 15 8 12
E32
690
Zubehör : siehe Seite 30
Einstellung STR55UE
Compact C801N/H/L In = 800 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 400 390 380 370 360 350 340 3200,63 504 491 479 466 454 441 428 4030,8 640 624 608 592 576 560 544 5121 800 780 760 740 720 700 680 640
Compact C1001N/H/L In = 1000 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 500 488 475 463 450 438 425 4000,63 630 614 599 583 567 551 536 5040,8 800 780 760 740 720 700 680 6401 1000 975 950 925 900 875 850 800
Compact C1251N/H/L In = 1250 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 625 609 594 578 563 547 531 5000,63 788 768 748 728 709 689 669 6300,8 1000 975 950 925 900 875 850 8001 1250 1219 1188 1156 1125 1094 1063 1000
Merlin Gerin30
Anzeigen und Zubehör für die elektronischenAuslösesysteme STR45AE/BE, STR55UE
90 105 %IrSTR 53 UE >7560 90 105 %Ir>7560
E23
534 Fehlermeldung - Option F
Option F ist fŸr den Auslšser STR45BEnicht verfŸgbar.
AnzeigeAlarm-LED
faulttest
µ P
> Ir
> Im
> Ih
Lastüberwachung - Option RIc1 = 0,8 bis 1Ic2 = 0,5 bis 16
0,8...1 IrIc16
E32
693
0,5...1 IrIc2
6
E32
694
0,2...0,6 InIh
0,1...0,4 sON I2t
th
7
8
E23
691
th
0,1...0,4 sI2t OFF
Ih 0,2...0,6 In
7
8
E32
692
on I2 t off
Ih
x In1.2
.3
.4.5 .6
.7
.8
.1.1
.2
.3.4 .4
.3
.2
th (s)
T
Erdschlußschutz - Option TErdschlu§schutzeinstellung fŸr Ihr Netz
Ih = von 0,2 bis 0,6 InI2t = konstant : ON oder OFF
th = 0,1 bis 0,4 s
7
8
STR45AE/BE STR55UEZubehör
E26
031
1.8
.85
.88.9 .93
.95
.98
R
Ic
E26
030
E26
029
31Merlin Gerin
Mit dem Testkoffer kann die Funktionder Auslšser ŸberprŸft werden durchMessen der tatsŠchlichen Auslšse-zeiten bei :c 1,5 x Ir (langzeitverzšgerter Schutz),c 1,5 x Ir (kurzzeitverzšgerter Schutz),c 0,8 x In (Erdschlu§schutz).Das GerŠt ŸberprŸft die Funktions-fŠhigkeit des Auslšsers und die Ab-schaltung des Leistungsschalters.
Testgerät
MERLIN GERIN
E23
858
E23
857
Testkoffer
Test elektronischerAuslösesysteme
Der Teststecker auf der Frontseite desLeistungsschalters ermšglicht denAnschlu§ eines TestgerŠtes oder einesTestkoffers.Das GerŠt ŸberprŸft die Funktions-fŠhigkeit des Auslšsers und die Ab-schaltung des Leistungsschalters.
Test elektronischer AuslösesystemeSTR22SE, STR23SE, STR53UE,STR25DE, STR35SE/GESTR45AE/BE, STR55UE
Merlin Gerin32
Einstellungen der elektronischenAuslöser STR22ME, STR35MEfür den Motorschutz
I
t
0
1
3
2
4
5
Ir 13Ir
E32
564
E26
985
Schutzeinstellungen (STR22ME)c Langzeitverzšgerter †berlastschutz,mit einstellbarem Ansprechwert Ir ,entspricht der TrŠgheitsklasse 10 nachIEC 947-4-1 ;c Schutz gegen einphasigen Betrieb :Auslšsung des Leistungsschalters in3,5 bis 6 s ;c Kurzzeitverzšgerter Kurzschlu§-schutz :v fester Ansprechwert, Im (13 x Ir) ,v fester Verzšgerung .c Unverzšgerter Kurzschlu§schutz, mitfestem Ansprechwert (13 x In) .
StandardanzeigenFrontseitige LED-Lastanzeige :c aus : I < 1,05 x In ;c blinkt : I u 1,05 x In.
Auslösesystem STR22MENennstrom(A) Ansprechwerte (A)40 24 25.5 27 28.5 30 32 34 36 38 4050 30 31.5 33.5 35.5 37.5 40 42.5 45 47.5 5080 48 51 54 57 60 64 68 72 76 80100 60 63 67 71 75 80 85 90 95 100150 90 95 101 107 113 120 127 135 142 150220 132 140 148 157 166 177 187 198 209 220
1
34
5
Ir ImIn=50A
IEC 947.4 / cl.10
Ir 13 Ir
7,2Ir
7,0s
Ir
u1,05 Ir
testA30 50
31.5 47.5
33.5 45
37.5 4035.5 42.5
STR 22 ME
1
2
33Merlin Gerin
Ir
Io
In
0.8 0.850.88 0.9 0.930.950.98 1
0.63 0.7 0.8 0.90.5 1
Ir = 320 A x 0.93 = 298 AIr = 320 A x 0.93 = 298 A
400 A
6 7 8 9 10 11 12 13Im
Ir = 320 A x 0.93 = 298 AIm = 298 A x10 = 2980 A
Einstellungen des elektronischenAuslösers STR43MEfür den Motorschutz
I
t
0
1
3
2
4
5
Ir
E32
566
E26
987
1
Schutzeinstellungen (STR43ME)c Langzeitverzšgerter †berlastschutz :v einstellbarer Ansprechwert Ir ,v einstellbare Reaktionszeit ,entsprechend TrŠgheitsklasse 5,10 und20 nach IEC 947-4.1 ;c Schutz gegen einphasigen Betrieb :Auslšsung in 4 s ± 10% ;c Kurzzeitverzšgerter Kurzschlu§-schutz :v einstellbarer Ansprechwert Im(6 bis 13 x Ir) ,v feste Verzšgerung ;c Unverzšgerter Kurzschlu§schutz, mitfestem Ansprechwert (13 x In) .
2
STR 43 ME
ImIr I
tr
tm10A
10
20
tr-
test
+
32
Io
1
µP >Ir >Im
.8
A
1
.7
.6
.90.93.95
.98
1
.88
.85
.8
9 1011
12
13
8
7
6x Io
Ir Im
x Ir
class 7.2 tr
3
E32
529
Compact NS630 Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 252 268 277 284 293 299 309 3150.63 318 337 349 357 369 377 389 3970.7 352 374 388 396 410 418 432 4410.8 403 428 443 472 469 479 494 504
Langzeitverzögerter Überlastschutz
Compact NS400 Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 160 170 176 180 186 190 196 2000.63 202 214 222 227 234 239 247 2520.7 224 238 246 252 260 256 274 2800.8 256 272 282 300 298 304 314 320
Grobeinstellung 320 A
Einstellungen der Schutzfunktionen(Beispiel)z.B. :
Erweiterte Einstellungen mit 150-250 A Stromwandlern
NS400 (150 A) Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 60 63,76 66 67,5 69,75 71,25 73,5 750.63 75,6 80,32 83,16 85,05 87,88 89,77 92,61 94,50.7 84 89,25 92,4 94,5 97,65 99,75 102,9 1050.8 96 102 105,6 138 111,5 114 117,6 120
NS400 (250 A) Ir (Feineinstellung)Io (Grobeinstellung) 0.8 0.85 0.88 0.9 0.93 0.95 0.98 10.5 100 106,25 110 112,5 116,25 118,75 122,5 1250.63 126 133,87 138,6 141,75 146,57 149,62 154,35 157,60.7 140 148,75 154 157,5 162,75 166,25 171,5 1750.8 160 170 176 180 185 190 196 200
5
4
E33
816
Im
x Ir
Ir
x Io
Io
x In136
3
45 6
7
81.8
.85
.88.9 .93
.95
.98.5
.63
.78 9
1
.5.63
.78 9
1
Im
x Ir
Ir
x Io
Io
x In1.8
.85
.88.9 .93
.95
.98136
3
45 6
7
8
1
Merlin Gerin34
Einstellungen des elektronischenAuslösers STR35MEfür den Motorschutz
E32
685
Io Ir
Io Ir
Io Ir
Einstellungen STR35ME
Compact C801N/H/L In = 800 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 400 390 380 370 360 350 340 3200,63 504 491 479 466 454 441 428 4030,8 640 624 608 592 576 560 544 5121 800 780 760 740 720 700 680 640
Compact C1001N/H/L In = 1000 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 500 488 475 463 450 438 425 4000,63 630 614 599 583 567 551 536 5040,8 800 780 760 740 720 700 680 6401 1000 975 950 925 900 875 850 800
Compact C1251N/H/L In = 1250 A
1 0.975 0.95 0.925 0.9 0.875 0.85 0,80,5 625 609 594 578 563 547 531 5000,63 788 768 748 728 709 689 669 6300,8 1000 975 950 925 900 875 850 8001 1250 1219 1188 1156 1125 1094 1063 1000
1
1
1
x Irx Iox In1.8.5
.8
Io1
Ir
.85
.9.95
Im
101.5
2
34 5
6
8.63off
E33
467
Beispiel :C1001N : In = 1000 A,
Im = 6000 A,
In
Io
Im
1000 A
0.4 0.5 0.63 0.8 1
Im = 6 x In = 6000 A
1
1.5 2 3 4 5 6 8 103
OFF
protection LR inopŽrante
précalibrage 1000 A
Irx Irx Iox In.5
.8
Io1
Ir Im
.63off
2
46
1.5 108
35
1.8.85
.9.95
Kurzzeitverzögerung
0...0,3 stm
I2t off tm
on I2t
0...0,3 s
4
C801 N/H LC1001N/H L C1251N/H
A 10 8 10B 15 8 12
E32
690
E33
468
15 8
C 801 N•HC 1001 N•H
LL
12C 1251N•H
t
i
Ir
Im
tm
I
120s
A
A1,5 Ir
x In
5
STR 35ME
.81
.5xIn
Io
60 70 80 90 % Ir105
test Ir Im
+ –
tm
.9.95
.8 1.85
4
6
1.5 10xIr
.3
0 0.1
.3.2
82
3
.2
.1
on I2t off
5
1 1 3 4
xIo
on off
off
LR inaktivLT nicht in FunktionIr = In
off
.63
Ir Im
3
I I
t
0
1
4
OFF
35Merlin Gerin
Zusätzliche Funktionen
Vigi-Block und Visu-Block ............................................................ 36
Stecksockel ........................................................................................ 37
Einschubchassis für Compact NS100 bis 630 ..................... 38
Multifunktionschassis für Compact C801 bis 1251 ........... 39
Abschließvorrichtungen ............................................................... 40
Abschließvorrichtungen und Plombiersätze ........................ 41
Merlin Gerin36
Vigi-Block und Visu-Block
Der Vigi-Block ist ein Differenzstrom-schutz-Auslšser. Er schŸtzt Personenvor indirektem Kontakt und Anlagen vorder Gefahr der Zerstšrung oder vorBrand aufgrund von ErdschlŸssen. DieAuslšsung des Schalters erfolgt direktauf mechanischem Wege.Der Vigi-Block kann mit einemFehlermeldeschalter (SDV) aus-gerüstet werden, der extern die Aus-lšsung des Leistungsschalters aufgrundeines Erdschlusses meldet.Die Test-Taste erlaubt eine regel-mŠ§ige FunktionsŸberprŸfung des Vigi-Blocks durch die Simulation eines Dif-ferenzstromfehlers. Vor der Durch-fŸhrung des Tests mu§ der Leistungs-schalter eingeschaltet werden.Die Reset-Taste :nach jeder Erdschlu§-Auslšsung mu§die Reset-Taste zur RŸckstellung desGerŠtes betŠtigt werden.
(1) Die Zwischenklemmenabdeckung ist zumBetrieb des Vigi-Blocks erforderlich.(2) Wird eine Ansprechempfindlichkeit von 30 mAeingestellt, wird die eingestellte Auslšse-verzšgerung nicht berŸcksichtigt.
Vigi-Block
E32
869
Leistungsschild
Visu-BlockDie Compact-Leistungsschalter fŸr denFesteinbau sind fŸr Stršme von 100 Abis 1250 A lieferbar. Sie kšnnen miteinem Visu-Block bestŸckt werden, dergemŠ§ der franzšsischen Norm NFC13.100 die Sichtbarkeit des Trenn-vorgangs gewŠhrleistet : die Kontaktesind durch eine transparente Adeckungsichtbar. Das Ein-und Ausschalten er-folgt Ÿber einen Hebel.Der Visu-Block kann mit VorhŠnge-schlšssern (Standard) oder mit einemZylinderschlo§ (Option) abgeschlossenwerden. Es gibt fŸr den Visu-Block spe-zielles Zubehšr : Hilfsschalter, Klem-menabdeckungen usw.Die Compact NS100/630 und C801/
1251 kšnnen mit einem Sicherheits-auslšser (Option) bestŸckt werden, derdas …ffnen des Blocks bei eingeschal-tetem Leistungsschalter verhindert.Der Visu-Block mu§ mit einem CAM-Schalter, der Leistungsschalter miteinem voltmetrischen Auslšser aus-gestattet sein.
Anschlußc fest vorderseitig : die Compact-Schalter mit Visu-Block sind fŸr den An-schlu§ von Stromschienen oder Kabelnmit Kabelschuhen vorbereitet ;c mit Kabeln ohne Kabelschuhe :einspeiseseitig mit Klemmen fŸr denVisu-Block, abgangsseitig mit KlemmenfŸr Compact NS-Schalter ;v Zubehšr : der Visu-Block kann mitAnschlu§verbreiterungen, (winkligen)
Anschlu§verlŠngerungen und Kabel-schuhen ausgestattet werden.c fest rŸckseitig : mit speziellen An-schlu§stŸcken fŸr Compact-Schaltermit Visu-Block, lieferbar pro Pol.Compact-Schalter mit Visu-Block kšn-nen mit speziellen, kurzen (rŸckseitigerAnschlu§) oder langen (vorderseitigerAnschlu§), plombierbaren Klemmen-abdeckungen ausgestattet werden.
ZubehörCompact NS100/630-Schalter mit Visu-Block kšnnen ausgestattet werden mit:c Im Visu-Block : Hilfsschaltern (OF,CAM), Ronis- oder Profalux-Zylinder-schlšssern, einem Kontakt fŸr die Er-dung des Nullpunktes (verpflichtet,wenn der Nullpunkt des Stromwandlersabgangsseitig des Compact-Schaltersmit Visu-block geerdet ist), usw.c Im Compact NS-GehŠuse : sŠmtlich-em Zubehšr fŸr Compact NS-Schalter.
E32
870
O
pushto
trip
O
380/415440500/525660/690250
7065501085
cat AIcs = 100% Icu
IEC 947.2UTE VDE BS CEI UNE NEMA
40/10040/100
R310
150
600
∆t(ms)
31
0.3
10
I∆n(A)
HS
avant test diŽlectriqueenlever ce couvercle
before dielectric testremove this cover
vigi
200/440 V - 50/60 Hz
-25
2 4 6
531N
T
0.03 (∆t = 0)
vigi MHNS 100/160 NHL
test
+
In=100A
ImIr
STR 22 SEIm
x Ir102
3
45 6
7
8
Ir
x Io1.8
.85
.88.9 .93
.95
.98
-
90105
alarm
Io
x In
.5.63
.7.8 .9
1
%Ir
Zwischenklemmenabdeckung (1)Plombierbare Schraube fŸr dieZwischenklemmenabdeckungPlombiermšglichkeit der Abdeckung derEinstellungenAbdeckplatte der EinstellungenTest-Taste
RŸckstelltaste (Reset)
Leistungschild
Platz fŸr SDV-Hilfsschalter (Option)
Einstellung der Auslšseverzšgerung (2)
Ansprechempfindlichkeit
avant test diŽlectriqueenlever ce couvercle
before dielectric testremove this cover
vigi
200/525 V - 50/60 Hz
-25
2 4 6
531N
T
NS 100/160 NHL
-25
Typ des Vigi-Blocks
Betriebsspannung und -frequenz
Normsymbole: (siehe Seite 4):
Unempfindlichkeit gegen Welle 8/20 und elektromagnetische Beeinflussungen
Klasse A. Unempfindlich fŸrGleichstromanteile bis 6 mAMinimale Betriebstemperatur gemŠ§ VDE 664
Schaltschema
37Merlin Gerin
Stecktechnik
Ausbau
pushto
trippush
totrip
3 - Den Leistungsschalter waagerechtherausziehen.
Die Hilfsstromkreise werden Ÿber denHilfsstromstecker auf der GerŠte-rŸckseite automatisch getrennt.
SicherheitsvorrichtungSollte der Leistungsschalter beimHerausziehen eingeschaltet sein (I/ON-Stellung), werden die Hauptpole auto-matisch gešffnet, bevor die Haupt-stromkreisstecker getrennt werden.
Einbau 1 - Leistungsschalter ausschalten.
2 - In den Stecksockel stecken.3 - Mit den Schrauben befestigen.4 - Der Schalter ist einsatzbereit.
Schutz gegen direkten Kontaktmit den Hauptstrombahnen
c Betriebsstellung : IP40(mit Klemmenabdeckungen),c Trennstellung : IP20,c Trennstellung, Stecksockel mitShutter : IP40.
1 - Den Leistungsschalter ausschalten.
pushto
trip
2 - Die 2 Befestigungsschraubenentfernen.
E32
519 E
3252
0
E32
541
Stecksockel
Merlin Gerin38
Einschubtechnik
Trennstellung
Einschubchassisfür Compact NS100 bis 630
Ausbau 1 - Den Leistungsschalter in Trenn-stellung bringen (siehe oben).2 - Gegebenenfalls den getrenntenHilfsstromkreisstecker ziehen.3 - Die beiden Verschlu§hebel wieoben drehen (Entriegeln).
4 - Die beiden Handgriffe nach untendrŸcken.5 - Den Leistungsschalter nach vorneherausziehen.
Hilfsschalter (Wechsler) :c Trennstellung,c Betriebsstellung.
Betriebsstellungsanzeige(Option)
Überprüfung derHilfsstromkreise
Diese Funktion steht zur VerfŸgung,wenn der Leistungsschalter mit einemgetrennten Hilfsstromkreisstecker aus-gerŸstet ist. In der Trennstellung kannder Leistungsschalter zur †berprŸfungder noch angeschlossenen Hilfsstrom-kreise betŠtigt werden. (Kipphebel,"push to trip"-taste).
Schutzgrad (Schalter in Trenn-stellung oder herausgezogen)
c Ohne spezielle AusrŸstung : IP20,c Stecksockel mit Shutter: IP40.
Einbau 1 - Die Beiden Verschlu§hebel drehen.2 - Die beiden Handgriffe gleichzeitignach oben drŸcken.
Die Sicherheitsvorrichtung funktioniertwie beim Trennen.
3 - Die beiden Handgriffe gleichzeitigherunterziehen, bis die Verschlu§hebel"klacken".
Hauptstrom- und Hilfsstromkreisewerden gleichzeitig getrennt, sofernkein getrennter Hilfsstromkreissteckerverwendet wird (siehe unten).Die Sicherheitsvorrichtung funktioniertwie bei den Leistungsschaltern inStecktechnik; die Hauptpole werdengešffnet, bevor die Hauptstromkreis-stecker getrennt werden.
1 - Den Leistungsschalter ausschalten.
2 - Die beiden Verschlu§hebel drehen.(Entriegeln).
pushto
trip
pushto
trip
E32
538
E32
539
E32
540
E23
894
CLACK
pushto
trip
CLACK
39Merlin Gerin
Das Multifunktionschassis fŸr dieCompact C801 bis C1251-Schalter istspeziell fŸr Hauptschalter geeignet :c BetŠtigung bei geschlossener TŸr miteiner im Chassis verstauten Kurbel ;c Anzeige der beiden Schaltstellungen(Betriebs- und Trennstellung) :v vor Ort durch eine Schaltstellungs-anzeige,v Fernanzeige Ÿber Hilfsschalter(jeweils 2 Schalter fŸr Betriebs- undTrennstellung) ;c Frontseitiges Ein- und Ausschaltendes Leistungsschalters.
AbschließvorrichtungenEine Reihe von Mšglichkeiten :c Abschlie§en des Chassis in Betriebs-oder Trennstellung mit 3 VorhŠnge-und 2 Zylinderschlšssern (frontseitigerZugang) ;c Abschlie§en der TŸr; verhindert das…ffnen wenn der Leistungsschalter sichin Betriebsstellung befindet ;c Kurbelverriegelung; verhindert Ein-fŸhren der Kurbel bei gešffneter TŸr.
TürausschnitteEin Satz Ausschnittblenden ermšglicht :c optimale Nutzung der Ausschnitte:Nur 1 Ausschnitt fŸr jeden Schalter ;v mit 3 oder 4 Polen,v mit Kipphebel- oder direktem Dreh-antrieb ;c die Schutzart IP 40.Der Satz beinhaltet :c eine TŸrausschnittblende fŸr die Vor-derseite des Chassis, die den Zugriffauf die Abschlie§vorrichtungen sowiedas Aus- und Einfahren ermšglicht.c eine TŸrausschnittblende zur Be-tŠtigung des Leistungsschalters, mitFenster fŸr die Auslšsereinstellungen.
Montagec rŸckseitige Befestigung auf einerMontageplatte oder Profilschienen ;c bodenseitige Befestigung auf einerMontageplatte oder Profilschienen ;NetzanschlŸssec Ÿber Kabel mit Kabelschuhen ;c Ÿber Flach- und HochkantanschlŸsseAnschlu§ von ZusatzausrŸstungen†ber den standard Compact C Zusatz-klemmenblock.
Leistungsschalter inMultifunktionschassis
1 2 3 4 5 6
7
8
9
10
11E32
687
Multifunktionschassisfür Compact C801 bis 1251
1 TŸrverriegelung (Option)
2 2 Hilfsschalter fŸr die Betriebsstellung(Option)
3 Schaltstellungsanzeige Betriebs-/Trennstellung
4 Verriegelung in der Trennstellung(Betriebsstellung) mit bis zu dreiVorhŠngeschlšssern
5 Aufnahme fŸr Kurbel
6 Verriegelung in der Trennstellung(Betriebsstellung) (Option)
7 Kurbelverriegelung (Option)
8 2 Hilfsschalter zur Anzeige derBetriebsstellung (Option)
9 Schlo§ als Ausfahrsperre fŸr denLeistungsschalter (1)
10 Shutter fŸr den Zusatzklemmenblock(Option)
11 Shutter IP 40 (Option)
E33
469
Ausschnittblenden fŸr Chassisfrontseiteund Kipphebel. bzw. Drehantrieb
TŸrausschnittblende fŸrdie Chassisvorderseite
TŸrausschnittblende fŸr den Kipp-hebelantrieb, mit Sichtfenster fŸrdie Auslšsereinstellungen
TŸrausschnittblende fŸr den Dreh-antrieb, mit Sichtfenster fŸr dieAuslšsereinstellungen
Merlin Gerin40
Welche Abschlie§vorrichtung auchbenutzt wird, das Auslösen im Fehler-falle ist immer vorrangig.c Vorrichtungen fŸr VorhŠngeschlšsserermšglichen die Verwendungen vonmaximal 3 VorhŠngeschlšssern miteinem Durchmesser von 5 bis 8 mm.
Drehantrieb direkttyp MCC
Funktion mittels Abschließ- für Leistungsschaltervorrichtung NS100É630 C801ÉC1251
Abschlie§en des Schalters VorhŠngeschlo§ Ð cin AUS-StellungSchalter in EIN-Stellung : Drehantrieb Ð cTŸr šffnen nicht mšglich (integriert)TŸr gešffnet : Schlie§en desSchalters nicht mšglich
Drehantrieb mit Türkupplung Funktion mittels Abschließ- für Leistungsschaltervorrichtung NS100É630 C801ÉC1251
Abschlie§en des Schalters VorhŠngeschlo§ Ð c cin AUS-StellungTŸr šffnen nicht mšglich SchlŸssel cSchalter in EIN-Stellung : Drehantrieb ÐTŸr šffnen nicht mšglich (integriert)TŸr gešffnet : Schlie§en desSchalters nicht mšglich
Drehantrieb direktstandard
Kipphebelantrieb Funktion mittels Abschließ- für Leistungsschaltervorrichtung NS100É630 C801ÉC1251
Abschlie§en des Schalters VorhŠngeschlo§ abnehmbar c cin AUS-StellungAbschlie§en des Schalters VorhŠngeschlo§ fest montiert cin AUS- oder EIN-Stellung
ONI
profalux
OOFF
profalux
profalux
Motorantrieb Funktion mittels Abschließ- für Leistungsschaltervorrichtung NS100É630 C801ÉC1251
Abschlie§en des Schalters VorhŠngeschlo§ Ð c cin AUS-StellungFernbetŠtigung nicht SchlŸssel 1 Zylinder- c cmšglich schlo§
pushto
trip
pushto
trip
2
1
Ipush ONO
push OFFmanuauto
pushto
trip
pushto
trip
E23
895
E32
537
E23
899
1 - Den frontseitigen Wahlschalter auf"Hand" setzen.2 - Den Verriegelungshebel ziehen3 - Das oder die VorhŠngeschlšsseranbringen.
In dieser Stellung ist es nicht mšglich,den Handgriff "Spannen von Hand",den EIN-Taster und den Wahltaster"Hand/Automatisch" zu betŠtigen.
Abschließvorrichtungen
E23
896
cDas Abschlie§en in der AUS-StellunggewŠhrleistet die sichere TrennunggemŠ§ IEC 947-2.
Funktion mittels Abschließ- für Leistungsschaltervorrichtung NS100É630 C801ÉC1251
Abschlie§en des Schalters VorhŠngeschlo§ Ð c cin AUS-Stellung SchlŸssel + Zylinder- c c
schlo§
41Merlin Gerin
Die unterschiedlichenPlombiersätze
Funktion mittels AbschließvorrichtungKein Einfahren des Schalters VorhŠngeschlo§ ÐAbschlie§en des Leistungsschalters SchlŸssel + Zylinderschlo§in Betriebs- oder Trennstellung
Plombiersatz für verhindert
Befestigungsschraube des c Entfernen des GehŠusdeckels
GehŠusedeckels c Zugriff auf das Zubehšr
c Entfernen des Auslšsers
Befestigungsschraube des c Demontage des Drehantriebs
Drehantriebs c Zugriff auf das Zubehšr
c Entfernen des Auslšsers
Verschlu§schraube der c Entfernen des Motorantriebs
Motorantriebshaube c Zugriff auf das Zubehšr
c Entfernen des Auslšsers
Transparente Schutzabdeckung VerŠnderung der Einstellungen : der Auslšsereinstellungen c des †berlastschutzes
c des Kurzschlu§schutzes
Transparente Schutzabdeckung VerŠnderung der Erdschlu§schutz-der Vigi-Block-Einstellungen einstellungen
Zwischenklemmen- c Ausschalten der Erdschlu§schutz-abdeckung des Vigi-Blocks funktion
c Zugang zu den HauptstromanschlŸssen(Schutz gegen direktes BerŸhren)
Befestigungsschraube der Zugang zu den StromanschlŸssenKlemmenabdeckung (Schutz gegen direktes BerŸhren)
Mechanische VerriegelungVerhindert, da§ sich zwei Schaltergleichzeitig in der EIN-Stellungbefinden.
Funktion mittelsVerriegelung von 2 Leistungsschaltern Mechanischer Doppelverriegelungmit KipphebelantriebVerriegelung von 2 Leistungsschaltern Mechanischer Verriegelungmit Drehantrieb 2 Schlšsser (1 SchlŸssel)
Einschubtechnik
pushto
trip
E23
900
E23
905
E23
906
E23
907
E23
905
E23
909
E23
908
E23
910
E23
911
Abschließvorrichtungen undPlombiersätze
Merlin Gerin42
43Merlin Gerin
Einsatz und Betrieb
Umgebungsbedingungen .................................................... 44
Inbetriebnahme und Betrieb ........................................................ 46
Fehlerdiagnose ................................................................................. 48
Praktische Hinweise ....................................................................... 49
Merlin Gerin44
Umgebungsbedingungen
Umgebungstemperatur
Compact NS-Leistungsschalter ent-sprechen den Anforderungen anmechanische oder elektromagnetischeVibrationsfestigkeit gemŠ§ folgenderNormen :c IEC 68-2-6,c Veritas NI122E,c Lloyd's Register of Shipping,c JIS 8370.
Vibrationen †bermŠ§ige Vibrationen kšnnen jedocheine Fehlauslšsung des Schalters, dasLšsen von Verbindungen oder sogarden Bruch von GerŠteteilen verursa-chen.
Die Compact NS-Leistungsschaltergarantieren die angegebenen Leis-tungsdaten bei Einsatz unter normalenKlimabedingungen. Sie haben die inden folgenden Normen definiertenTests ohne Leistungsreduzierungenbestanden :c IEC 68-2-2: Trockene WŠrme +85°C,c IEC 68-2-1: Trockene KŠlte Ð55°C,c IEC 68-2-30: Temperatur und Luft-feuchte (Temperatur + 55°C, relativeLuftfeuchtigkeit 95 %),c CE 68-2-11: Salznebel.
Besondere Umgebungs-bedingungen
Compact NS-Leistungsschalter sind fŸrden Betrieb unter industriellen Einsatz-bedingungen gemŠ§ IEC 947 (Ver-schmutzungsgrad i3) ausgelegt.
Es wird jedoch empfohlen, denLeistungsschalter in einem belŸftetenund relativ staubdichten Schaltschrankeinzusetzen.
BetriebUmgebungstemperaturen zwischen–25°C und +40 °C :Die angegebenen Leistungsdatenwerden garantiert, wenn die Luft-temperatur in unmittelbarer NŠhe desCompact NS-Leistungsschalters inner-halb dieses Bereiches liegt.
Umgebungstemperaturen zwischen+40°C und +70°C :Tragen Sie mit den in der technischenUnterlagen angegebenen Redu-zierungskoeffizienten Rechnung :c Bei Leistungsschaltern mit thermo-magnetischen Auslšsern wird derAuslšsestrom Ir temperaturabhŠngigreduziert (†berlastschutz),c FŸr Leistungsschalter mit elektroni-schen Auslšsern ist die maximalzulŠssige Einstellung des †berlast-schutzes zu beachten.
Umgebungstemperaturen über+70°C :Verschiedene Systeme lšsen denLeistungsschalter aus, als Schutz vorden Auswirkungen einer †bertem-
peratur. Daraus folgt, da§ die Betriebs-kontinuitŠt der elektrischen Anlagenicht garantiert werden kann, wenn derLeistungsschalter bei TemperaturenŸber 70°C eingesetzt wird.In diesem Fall sollte durch Eigen- oderFremdbelŸftung dafŸr gesorgt werden,da§ die Temperatur im Schaltschrankdie 70°C nicht Ÿbersteigt.
Lagerung und InbetriebnahmeOriginal verpackte Compact NS-Leistungsschalter kšnnen bei Tem-peraturen zwischen –55°C und +85°Cgelagert werden.
Die Inbetriebnahme sollte bei normalenUmgebungstemperaturen erfolgen(siehe oben). In AusnahmefŠllen kannsie auch bei Temperaturen zwischen Ð35°C und Ð25°C durchgefŸhrt wer-den.
45Merlin Gerin
Höhenlagen
Compact NS-Leistungsschalter miteinem elektronischen Auslšser undeinem Vigi-Block sind geschŸtzt gegen:c †berspannung durch elektroma-gnetische SchaltgerŠte,c †berspannung durch atmosphŠrischeStšrungen, die im elektrischen Netzweitergeleitet werden (z.B. : Blitz-einschlag),c hochfrequente Stšrungen (Funk-gerŠte, Walkie-Talkies, Radaranlagen,usw ...),c Entladungen statischer ElektrizitŠt,direkt durch die Bediener.
ElektromagnetischeBeeinflussung
Sie haben die EMV-PrŸfungen derfolgenden internationalen Normenbestanden :ccccc IEC 255-22-1 SchŠrfegrad 3 :v 10 kV 1,2 / 50 µs †berspannungs-welle,v 2,5 kV 1 MHz gedŠmpfteSchwingungswelle,ccccc IEC 1000-4-2 SchŠrfegrad 4 :Entladung statischer ElektrizitŠt 15 kV,ccccc IEC 1000-4-3 SchŠrfegrad 3 :10 V/m elektromagnetische Strahlungs-felder ,ccccc IEC 1000-4-4 SchŠrfegrad 4 :4kV schnelle transiente Stšrgrš§en,ccccc IEC 1000-4-5 SchŠrfegrad 4 :v 4kV 1,2 / 50 µs Spannungswellen,v 2 kA 8 / 20 µs Stromwellen,ccccc EN 50081-1 Klasse B :Leitungs- und Strahlungsemissionen inSchaltanlagen,c IEC 947-2 Anhang F.
Diese Tests gewŠhrleisten :c Betrieb ohne Fehlauslšsungen,c †berlast-Auslšsezeiten.
Die Compact NS-LeistungsschaltergewŠhrleisten die angegebenenLeistungsdaten bei Einsatzhšhen bis2000m.
Hšhe (m) i 2000 3000 4000Maximale Betriebsspannung (V) 690 600 480Bemessungsstrom (A) bei 40°C In 0,96 x In 0,93 x In
†ber 2000m mu§ wegen abnehmenderdielektrischen Festigkeit und geringererKŸhlwirkung der Luft mit folgenden Kor-rekturfaktoren gerechnet werden:
Merlin Gerin46
Inbetriebnahme und Betrieb
Vor Inbetriebnahme neuerLeistungsschalter odernach einer längerenStillegung
Eine allgemeine †berprŸfung kostet nurwenige Minuten. Sie verhindert aberBetriebsstšrungen aufgrund von Feh-lern oder FahrlŠssigkeit.
Bei allen Überprüfungen muß dieSchaltanlage abgeschaltet sein. Beigeteilten Schaltanlagen genügt eineSpannungsfreiheit des jeweils zu-gänglichen Teils.
†berprŸfungen der Isolation und derdielektrischen Festigkeit werden vorLieferung der Schaltanlage durchge-fŸhrt. Sie unterliegen den einschlŠgigenVorschriften und dŸrfen nur von hierzuausgebildetem Fachpersonal durchge-fŸhrt werden.
A B C D E F GVor Inbetriebnahme c c c c c c cPeriodisch Ÿber die gesamte Lebensdauer c c cNach Wartungsarbeit an der Schaltanlage c c c c cPeriodisch wŠhrend einer lŠngeren Stillegung c c cNach einer lŠngeren Stillegung (1) c (2) c c c c
Elektrische Überprüfungen
Inspektion der Schaltanlage Die Leistungsschalter sind in einersauberen, staubfreien Umgebung zuinstallieren. Alle nicht mehr benštigtenWerkzeuge und Materialien (Kabel,Splitter, Metallpartikel, uswÉ) sindnach der Installation zu entfernen.
Übereinstimmung mit demSchaltplan
Die †bereinstimmung der GerŠte mitdem Schaltplan ŸberprŸfen :v Bemessungsdaten und Schalt-vermšgen gemŠ§ Leistungsschild,v Typ und Grš§e der Auslšser,v Vorhandensein zusŠtzlicherFunktionen (Differenzstrom-AuslšserVigi-Block, Motorantrieb, Drehantrieb,Zubehšr, Melde- und Me§module),
v Schutzeinstellungen (†berlast, Kurz-schlu§, Erdschlu§),v Abgangsseitige Stromkreiskenn-zeichung auf der GerŠtefrontseite,v FŸr Vigicompact-Schalter: sicher-stellen, da§ die Zwischenklemmen-abdeckung installiert ist, sonst ist derDifferenzstromschutz nicht aktiv.
Montage des Gerätes -Zustand der Anschlüsse und desZubehörs
Den Einbau des Gerätes in der Schalt-anlage und die StromanschlŸsse Ÿber-prŸfen.
Sicherstellen, da§ die ZubehörteileordnungsgemŠ§ auf den GerŠteninstalliert sind :v Drehantrieb und Motorantrieb,v Zubehšr (Klemmenabdeckungen,TŸrausschnittblenden, etcÉ),v Anschlu§ der Hilfsstromkreise.
Mechanischer Betrieb Den mechanischen Betrieb der GerŠteŸberprŸfen :v …ffnen der Kontakte,v Schlie§en der Kontakte,v Testauslšsung mit der Auslšsetaste"push-to-trip".
Betrieb der elektronischenAuslöser und des Vigi-Blocks
Die Vigi-Blöcke durch BetŠtigen derfrontseitigen Test-Taste ŸberprŸfen.Dieser Test gewŠhrleistet dieAuslšsung des Leistungsschalters imErdschlu§falle.
Den elektronischen Auslöser mittelseines TestgerŠtes oder TestkoffersŸberprŸfen (siehe Seite 13).
A Elektrische †berprŸfungenB Inspektion der SchaltanlageC Übereinstimmung mit dem SchaltplanD Montage des GerŠtes - Zustand derAnschlŸsseE Zustand des Zubehšrs
F Mechanischer BetriebG Betrieb der elektronischen Auslšserund des Vigi-Blocks.
(1) Im Falle einer lŠngeren Stillegung oder €nder-ungen der Schaltanlage.(2) Im Falle von €nderungen der Schaltanlage.
47Merlin Gerin
Nach einer Auslösung
Ursache der Auslösung Es gibt verschiedene Ursachen :c Je nach Ausstattung des Leistungs-schalters, kšnnen bestimmte Hilfs-schalter (SD, SDE, SDV,É) oder LED-Anzeigen auf der Leistungsschalter-frontseite die Identifizierung der Aus-lšsungsursache erleichtern.(siehe Tabelle Seite ??),
c Je nach Ursache der Auslšsung sindvor der Wiederinbetriebnahme derAnlage bestimmte Vorsichtsma§-nahmen zu beachten. Es betrifft hierdie †berprŸfung der Isolation und derdielektrischen Festigkeit eines Teilesoder der gesamten Anlage. Die †ber-prŸfungen dŸrfen nur von Fachkun-digem Personal durchgefŸhrt werden.
Rückstellung des SchaltersBefindet sich der Leistungsschatler inder "Ausgelšst"-Stellung, mu§ er zuerstzur RŸckstellung in die AUS-Stellung(O/OFF) und erst danach in die EIN-Stellung (ON) gebracht werden.
DrehantriebKipphebelantrieb
Ausgelöst-AnzeigeDie Auslšsung wird auf derGerŠtefrontseite angezeigt :
mit Drehantrieb mit Motorantriebmit Kipphebelantrieb
Der Leistungsschalter darf NIErückgestellt werden, bevor die Ur-sache der Auslösung identifiziertund behoben ist.
pushto
trip
2
1I
push ONOpush OFF
manu/auto
O OFF discharged
E32
881
E32
882
E32
883
E32
506
E32
884
MotorantriebSiehe Vorgehen auf Seite ??.
pushto
trip
ON (EIN)
Ausgelöst
OFF (AUS/getrennt)
pushto
trip
ONI
OOFF
ON (EIN)
OFF (AUS/getrennt)
Ausgelöst
pushto
trip
ONI
OOFF
ON
OFF
einschalten
rückstellen
ausgelöstpush
totrip
OFF "O"
ON "I" Einschalten
Rückstellen
Ausgelöst
Merlin Gerin48
Fehlerdiagnose
Die nachfolgende Tabelle enthŠlt nichtalle mšglichen Fehlerursachen. Sieerleichtert jedoch die Fehlerdiagnoseund bietet geeignete AbhilfevorschlŠge.
Sollten Sie das Problem nicht lšsenkšnnen, wenden Sie sich bitte an dieService-Abteilung von Merlin Gerin.
SDSDESDV
SDSDE
SDSDE"Alarm"am elektron.Auslšser
SDSDE
SDESD
Problem Anzeige Mögliche Ursachen Abhilfe
Wiederholte Auslösung
c Schutzeinstellungen sind nicht korrekt oder Bemessungsstrom des Versorgungsnetzesgeeignet. ŸberprŸfen und den richtigen Wert ein-.
stellen.Einstellung des †berlastschutzes Ÿber-prŸfen.
SD c Versorgungsspannung des Unterspannungs- Wert der Spannungsversorgung Ÿber-auslšsers MN ist zu niedrig oder gro§en prŸfen und anpassen.Schwankungen unterworfen.
(DC-Netze unterliegen bei Lastzuschalt-ung gro§en Spannungsschwankungen.SpannungseinbrŸche kšnnen das Aus-lšsen des Schalters durch den MN-Auslšser bewirken).
SD c Unbeabsichtigte Spannungsversorgung des Ursache herausfinden und beheben.Arbeitsstromauslšsers MX.
c Umgebungstemperatur zu hoch. Raum oder GerŠt belŸften.
c Vigi-Block-Einstellungen inkorrekt.
c Isolationsfehler. Isolation des Stromkreises ŸberprŸfen.
Die Hauptkontakte schließen nicht
Handbetrieb c Versorgungsnetzfehler. Fehler identifizieren und beheben.
SD c Arbeitsstromauslšser MX liegt Ursache herausfinden und beheben.an Spannung.
c Keine Spannungsversorgung des Spannungsversorgung Ÿber die KlemmenUnterspannungsauslšsers MN. und AnschlŸsse ŸberprŸfen.
OF c Verriegelung des Leistungsschalters. Installationsplan und Verriegelungssystem(mechanisch oder elektrisch) der 2Leistungsschalter ŸberprŸfen.
Motorantrieb OF c Einschaltbefehl nicht aktiv. c AUTO-Stellung des Schalters Ÿber-prŸfen.c Spannungsversorgung des Motorantriebs,des Motors und der Steuerstromkreise Ÿber-prŸfen.
c Die Auslšsung erfolgt aufgrund eines c Fehler identifizieren und beheben.elektrischen Fehlers. c Federkraftspeicher von Hand spannen.
49Merlin Gerin
Erhöhte Sicherheit
Mehr Bedienungskomfort
Folgendes Zubehšr ist erhŠltlich:c Lange oder kurze Klemmenab-deckungen, die Schutzart IP 403 ge-wŠhrleisten,c plombierbare Abdeckung derSchutzeinstellungen(thermomagnetische Auslšser),c flexible Phasentrenner sichern dieIsolierung im Bereich der Strom-anschlŸsse,c Kipphebelblende, die SchutzartIP435 gewŠhrleistet.
c eine komplette Baureihe elektri-scher Meldeschalter (OF, SD, SDE,SDV),c Spannungsmelder an den Klem-menanschlŸssen,c Strommeßmodul mit integriertemAmperemeter oder externer Anzeigeder Me§werte,c Bezeichnungsschilder (sieheTelemecanique Katalog Typ. AB1),c Alarmanzeige (standardmŠ§ig anGerŠten mit elektronischen Auslšsern).
c Meldeoptionen fŸr den elektro-nischen Auslšser STR53UE (sieheSeite 12),c Dialpact-Module fŸr Melde-, Me§-und Steuerungsfunktionen.
Praktische Hinweise
Leistungsfähigkeit aufDauer
Konstruktionsbedingt benötigen dieCompact NS-Leistungsschalterkeine Wartung.Es sollte jedoch darauf geachtet wer-den, da§ die GerŠte unter den imKatalog angegebenen Betriebs-bedingungen eingesetzt werden:
c elektrische und mechanischeBedingungen,c Umbegungsbedingungen.(siehe Seite 44 und 45).
Bei Schaltern in Stecktechnik kann derStecksockel ausgerŸstet werden mit :c Shutter, die den Zugang zuspannungsfŸhrenden Teilen verhindern(Schutzart IP40).
Ästhetisches Design c gro§e Auswahl an Türausschnitt-blenden, fŸr unterschiedliche Schutz-arten (IP) fŸr GerŠte fŸr Festeinbau, inSteck- oder Einschubtechnik, Motor-antrieb und Drehantrieb.
E32
885
E32
886
E32
887
pushto
trip
pushto
trip
pushto
trip
Merlin Gerin50
Notizen
51Merlin Gerin
Merlin Gerin52
Notizen