  • JOB NO:

    DRAWING ABBREVIATIONS AND LEGENDS: A.B. ANCHOR BOLT ADD'L ADDITIONAL AD.TH. ADJUSTABLE THRESHOLD A.F.F. ABOVE FINISHED FLOOR ALUM. ALUMINUM ANOD. ANODIZED ARCH. ARCHITECTURAL A.C.P. ALUMINUM COMPOSITE PANEL ACT. ACOUSTICAL TILE B/ BOTTOM OF BLDG. BUILDING BLK. BLOCK BM. BEAM BOT. BOTTOM BRG. BEARING CPT. CARPET C.J. CONSTRUCTION OR CONTROL JOINT CL. CENTERLINE CLR. CLEAR FINISH COL. COLUMN CONC. CONCRETE CONN. CONNECTION CNST. CONSTRUCTION CONT. CONTINUOUS CRT. CARPET TILE C.S. CONCRETE SEALER C.T. CERAMIC TILE C.W.C. CLOTH WALL COVERING DET. DETAIL DIA. DIAMETER DIM. DIMENSION DO. DITTO DWG. DRAWING D.W. DRY WALL EA. EACH E.B. EXPANSION BOLT E.J. EXPANSION JOINT EL. ELEVATION E.S. EXPOSED STRUCTURE EXIST. EXISTING EXT. EXTERIOR

    F.D. FLOOR DRAIN FDN. FOUNDATION F.F. FINISH FLOOR FTG. FOOTING GA. GAGE OR GAUGE GALV. GALVANIZED GP. BD.GYPSUM BOARD GL. GLASS G.S.F. GROOS SQUARE FOOT HT. HEIGHT H.P. HIGH POINT H.S.B. HIGH STRENGTH BOLTS H.C. HOLLOW CORE H.M. HOLLOW METAL HOR. HORIZONTAL HR. HOUR I.D. INSIDE DIAMETER INT. INTERIOR LAV. LAVATORY LG. LONG L.L.H. LONG LEG HORIZONTAL L.L.V. LONG LEG VERTICAL L.P. LOW POINT MAS. MASONRY MAX. MAXIMUM MECH. MECHANICAL MFR. MANUFACTURER MIN. MINIMUM MTL. METAL N.A. NOT AVAILABLE N.T.S. NOT TO SCALE O.C. ON CENTER O.D. OUTSIDE DIAMETER OPNG. OPENING OPP. OPPOSITE P.T. PAINT P.B.D. PARTICLE BOARD PL. PLATE P.LAM. PLASTIC LAMINATE PLWD PLYWOOD P.S.F. POUNDS PER SQUARE FOOT P.S.I. POUNDS PER SQUARE INCH

    Q.T. QUARRY TILE R. RADIUS REBAR REINFORCEMENT BAR REINF. REINFORCEMENT REQ'D. REQUIRED RI. RISER S.C. SOLID CORE SECT. SECTION SHT. SHEET SIM. SIMILAR S.O.G. SLAB ON GRADE ST. STAIN STD. STANDARD STIFF. STIFFENER STL. STEEL STRUCT. STRUCTURAL ST/V STAIN AND VARNISH S.V.T. SHEET VINYL TILE T/ TOP OF T&B TOP AND BOTTOM TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE V. VINYL VERT. VERTICAL VCT. VINYL TILE V.W.C. VINYL WALL COVERING V.W.O. VERIFY WITH OWNER W/ WITH W/O WITH OUT WD. WOOD WDW. WINDOW W.P. WORK POINT W.PNL. WAINSCOT PANELING W.R. WATER RESISTANT GYPSUM BOARD W.W.R. WELDED WIRE REINFORCEMENT

    ORLAND PARK, IL

    ORLAND FIRE PROTECTION DISTRICT

    7208.07 APRIL 30, 2020 ISSUE FOR PRECAST BID

    NEW MAINTENANCE FACILITY

    10704 W. 163RD PLACE

    DRAWING SHEET INDEX

    CS COVER SHEET

    A-0.1 GENERAL SPECIFICATIONS

    A-0.2 CODE ANALYSIS

    A-1.0 FLOOR PLANS

    A-1.1 REFLECTED CEILING PLAN

    A-1.2 ROOF PLAN

    A-1.3 ENLARGED PLANS

    A-1.4 INTERIOR ELEVATIONS

    A-2.0 EXTERIOR ELEVATIONS

    A-2.1 EXTERIOR ELEVATIONS

    A-3.0 BUILDING SECTIONS

    A-3.1 WALL SECTIONS

    A-3.2 WALL SECTIONS

    A-4.0 CANOPY DETAILS

    A-5.0 DOOR SCHEDULE

    A-5.1 DETAILS

    A-6.0 STAIR DETAILS

    A-7.0 ROOM FINISH SCHEDULE AND WALL TYPES

    S-0.1 STRUCTURAL SPECIFICATIONS

    S-1.0 FOUNDATION PLAN

    S-1.1 FOUNDATION DETAILS

    S-2.0 FRAMING PLANS

    S-2.1 CANOPY FRAMING

    S-2.2 FRAMING DETAILS

    M-1.1 MECHANICAL FLOOR PLANS

    M-1.2 MECHANICAL PIPING PLANS

    M-1.3 MECHANICAL ROOF PLAN

    M-2.1 MECHANICAL SCHEDULES

    M-2.2 MECHANICAL SCHEDULES

    M-2.3 MECHANICAL DETAILS

    M-2.4 MECHANICAL DETAILS

    M-2.5 MECHANICAL NOTES & LEGENDS

    M-3.1 ALTERNATE RADIANT HEAT - FIRST FLOOR PLAN

    M-3.2 ALTERNATE RADIANT HEAT - GAS PIPING PLAN

    M-3.3 ALTERNATE RADIANT HEAT - DETAILS

    E-1.1 FIRST FLOOR POWER PLAN

    E-1.2 FIRST FLOOR LIGHTING PLAN & MEZZANINE POWER PLAN

    E-2.1 FIRST FLOOR LIGHTING PLAN & MEZZANINE LIGHTING PLAN

    E-3.1 FIRST FLOOR FIRE ALARM PLAN

    E-3.2 MEZZANINE FIRE ALARM PLAN

    E-4.1 ELECTRICAL SYMBOLS & SPECIFICATIONS

    E-4.2 ELECTRICAL SCHEDULES

    E-5.1 ELECTRICAL RISER DIAGRAM

    E-5.2 PANEL SCHEDULES

    E-6.1 DETAILS

    E-7.1 ELECTRICAL SITE PLAN

    P-1.1 UNDERGROUND PLUMBING PLAN

    P-1.2 ABOVE GROUND PLUMBING

    P-1.3 ROOF PLUMBING

    P-1.4 PLUMBING DIAGRAMS

    P-1.5 PLUMBING DIAGRAMS

    P-2.1 PLUMBING NOTES, SYMBOLS, & SPECIFICATIONS

    BUILDING DATA CONSTRUCTION TYPE: IIB (NON-COMBUSTIBLE)

    NON-SEPARATED USE

    BUILDING USE GROUP: B (BUSINESS) S-1 (STORAGE)

    FULLY SPRINKLERED WITH FIRE ALARM

    ACTUAL BUILDING AREA: 16,567 S.F.

    ACTUAL BUILDING HEIGHT: 36'-4"

    BUILDING CODES 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL MECHANICAL CODE 2014 ILLINOIS PLUMBING CODE 2017 NATIONAL ELECTRICAL CODE 2012 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL ENERGY CONSERVATION CODE 2018 STATE OF ILLINOIS ACCESSIBILITY CODE

    LOCATION MAP:

    STATEMENT OF COMPLIANCE I HAVE PREPARED, OR CAUSED TO BE PREPARED UNDER MY DIRECT SUPERVISION, THE ATTACHED DRAWINGS AS LISTED ON THIS COVER SHEET AND STATE THAT THEY, TO THE BEST OF MY KNOWLEDGE AND BELIEF, ARE IN COMPLIANCE WITH THE ENVIRONMENTAL BARRIERS ACT ( 410 ILCS 25), THE ILLINOIS ACCESSIBILITY CODE (71 ILL. ADM. CODE 400.), AND THEY COMPLY WITH THE ORDINANCES AND BUILDING CODES OF THE MUNICIPALITY OF CAROL STREAM SIGNED:

    DATE: 4-30-2020

    JON S. DITTER, ARCHITECT ILLINOIS LICENSE NUMBER: 001-018777 DATE OF EXPIRATION: 11-30-2020

    KNIGHT E/A, INC. PROFESSIONAL DESIGN FIRM ILLINOIS LICENSE NUMBER: 184-002141 DATE OF EXPIRATION: 4-30-2021

    FOR:

  • ALL MATERIALS USED AND WORK PERFORMED WILL BE IN COMPLIANCE WITH ALL CURRENT LAWS OF THE STATE OF ILLINOIS, CITY / VILLAGE, OR OTHER AUTHORITIES HAVING LAWFUL JURISDICTION. ALL REQUIRED BUILDING PERMITS ARE INCLUDED.

    PRIOR TO CONSTRUCTION, LOCATE AND DO NOT DISTURB UTILITY LINES (INCLUDING GAS, WATER, SEWER, TELEPHONE) OR DISCONNECT SAME, UNLESS PROPER PRECAUTIONS ARE TAKEN TO PROVIDE THE SAME UTILITIES ON A TEMPORARY OR PERMANENT BASIS, WITHOUT LOSS OF CONTINUITY.

    THE CONTRACTOR SHALL ARRANGE FOR A TEMPORARY WATER SUPPLY AND ELECTRICAL SERVICE TO THE PROJECT.

    PROVIDE ALL BARRICADES OR OTHER TEMPORARY PROTECTION AS MAY BE REQUIRED FOR GENERAL SAFETY AROUND ALL OPEN PITS OR TRENCHES IN PROJECT VICINITY. IN ADDITION, CONTRACTOR IS RESPONSIBLE TO COMPLY WITH ALL O.S.H.A. REQUIREMENTS FOR ALL APPLICABLE SAFETY STANDARDS.

    PROVIDE ONE YEAR GUARANTEE ON ALL MATERIALS AND WORKMANSHIP, UNLESS OTHERWISE NOTED.

    THE CONTRACTOR AND SUBCONTRACTOR SHALL MAINTAIN SUCH INSURANCE AS WILL PROTECT HIM FROM CLAIMS UNDER WORKMEN'S COMPENSATION ACTS AND OTHER EMPLOYEE BENEFIT ACTS, FROM CLAIMS FOR DAMAGES BECAUSE OF BODILY INURIES, INCLUDING DEATH TO HIS EMPLOYEES AND ALL OTHERS, FROM CLAIMS FOR DAMAGES TO PROPERTY ANY OR ALL OF WHICH MAY ARISE OUT OF OR RESULT FROM THE CONTRACTOR'S OPERATIONS UNDER THIS CONTRACT.

    KEEP SITE OF OPERATIONS FREE FROM ACCUMULATIONS OF RUBBISH AND WASTE MATERIALS AT ALL TIMES. SUBCONTRACTORS ARE TO REMOVE AND DISPOSE OF THEIR RUBBISH. ON A DAILY BASIS

    EACH CONTRACTOR AND SUBCONTRACTOR SHALL REMOVE AND/OR DISPOSE OF ALL TOOLS, EQUIPMENT, SURPLUS MATERIALS, AND RUBBISH PERTAINING TO HIS WORK, AND COOPERATE WITH THE OWNER IN FINAL CLEANING OF THE SITE.

    EACH AND EVERY CONTRACTOR AND SUBCONTRACTOR PERFORMING WORK AT THE SITE OF THE PROJECT TO WHICH THIS CONTRACT RELATES, SHALL COMPLY WITH APPLICABLE PROVISIONS OF ALL PERTINENT FEDERAL AND STATE LABOR LAWS.

    EACH CONTRACTOR, PRIOR TO SUBMITTING HIS BID, SHALL THOROUGHLY EXAMINE THE DRAWINGS AND SPECIFICATIONS OF THE CONTRACT DOCUMENTS, AND VISIT THE SITE TO BECOME FULLY AWARE AND KNOWLEDGEABLE OF ALL WORK AND CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. THE SUBCONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY ERRORS, DISCREPANCIES, OR AMBIGUITIES FOUND IN THE CONTRACT DOCUMENTS AT LEAST THREE WORKING DAYS PRIOR TO THE BID DUE DATE. THE ARCHITECT SHALL ISSUE WRITTEN ADDENDA PRIOR TO THE BID DUE DATE TO RESOLVE THE ERROR, DISCREPANCY, OR AMBIGUITY. THE SUBCONTRACTOR, IN SUBMITTING HIS BID, ASSUMES RESPONSIBILITY FOR DISCREPANCIES FOR WHICH HE DID NOT NOTIFY THE ARCHITECT.

    EACH CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY DIMENSIONS AT SITE FOR ALL WORK AND/OR WORK ADJOINING THAT OF OTHER TRADES AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING OF WORK.

    1. GENERAL REQUIREMENTS

    A. LAW COMPLIANCE:

    B. UTILITIES:

    C. TEMPORARY WATER AND ELECTRICAL SERVICE:

    D. PROTECTION:

    E. GUARANTEE:

    F. INSURANCE:

    G. HOUSEKEEPING:

    H. FINAL CLEANING:

    I. LABOR LAW:

    J. CORRELATION AND INTENT:

    K. DIMENSIONS:

    DIVISION 03 CONCRTE

    FURNISH ALL LABOR, EQUIPMENT, AND MATERIAL NECESSARY TO PROVIDE ALL COLD FORMED METAL FRAMING SYSTEMS SHOWN ON THE DRAWINGS. WORK SHALL MEET THE REQUIREMENTS OF THE LATEST EDITION OF THE FOLLOWING STANDARDS:

    1. AMERICAN IRON AND STEEL INSTITUTE (A.I.S.I.) DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS

    2. AMERICAN WELDING SOCIETY (A.W.S.) D13 STRUCTURAL WELDING CODE - SHEET STEEL

    3. AMERICAN SOCIETY FOR TESTING AND MATERIALS (A.S.T.M.)

    4. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (A.I.S.C.) MANUAL OF STEEL CONSTRUCTION

    5. ALL PERTINENT FEDERAL, STATE AND LOCAL CODES

    6. LIGHT GAUGE FRAMING CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND VERIFICATION OF ALL WALLS, HEADERS, JOIST, BRACING, CONNECTIONS, ETC.

    A. STEEL: SEE STRUCTURAL DRAWINGS

    B. COLD FORMED FRAMING:

    1. ALL INTERIOR DOORS AND FRAMES 2. HOLLOW METAL DOOR FRAMES 3. ALL FINISH HARDWARE AND SIGNS 4. PLASTIC LAMINATE TOPS 5. WOOD/ PLASTIC LAMINATE CABINETRY 6. FIRE EXTINGUISHERS AND CABINETS 7. MIRRORS AND TOILET ACCESSORIES 8. TOILET PARTITIONS AND URINAL SCREENS 9. SOLID SURFACE TOPS

    ALL ROUGH LUMBER SHALL CONFORM TO 'VOLUNTARY PRODUCTS STANDARD PS-20-70 AMERICAN