naomi_digital_x-ray_brochure_2010

12

Upload: giss-marketing

Post on 07-Mar-2016

212 views

Category:

Documents


0 download

DESCRIPTION

naomi_digital_x-ray_brochure_2010

TRANSCRIPT

Page 1: naomi_digital_x-ray_brochure_2010
user
Stamp
Page 2: naomi_digital_x-ray_brochure_2010
user
Stamp
Page 3: naomi_digital_x-ray_brochure_2010

From CR to DR .................................. 02

No.1 Share in DR Market .................... 04

Features .............................................. 06

Operation ........................................... 08

Optional Items .................................... 10

Specifications ...................................... 12

Support / After-Service ....................... 13

Contents

Densely aligned CCD sensors with our own unique technology

user
Stamp
Page 4: naomi_digital_x-ray_brochure_2010

02

From CR to DRSince Dr. Roentgen discovered the x-ray in 1895, we used films to capture its light.As the market continues to move towards film-less radiology, the technology to detect x-ray has changed from film-base to CR and now to DR system.Densely aligned CCD sensors in NAOMI are now opening a new frontier in digital radiography to make the radiography process more effective and faster.

user
Stamp
Page 5: naomi_digital_x-ray_brochure_2010

Direct Digital Radiography CCD Imaging Sensor 03

user
Stamp
Page 6: naomi_digital_x-ray_brochure_2010

04

In 2007the No.1 Sharein DR Market* Researched by Yano Research Institute of Economy

Digital radiography system, NAOMI has honorably achieved the top share in DR market among private clinics in 2007. We are striving everyday to develop products to meet the customers' needs.

user
Stamp
Page 7: naomi_digital_x-ray_brochure_2010

Direct Digital Radiography CCD Imaging Sensor 05

192 CCD sensors in the digital radiography system, NAOMI

user
Stamp
Page 8: naomi_digital_x-ray_brochure_2010

Features

06

48 Megapixel High Image QualityNAOMI uses the maximum of 192 monochrome CCD sensors. By aligning them densely with our unique technology, NAOMI has achieved to capture the intense concentration of light and generates 48 megapixel image quality. The newly developed high-performance engine displays the image smoothly in 4096 gray scales (12 bit). A single image contains immense data information to be displayed, from soft tissue to osseous part in smoother and deeper levels of contrast.

From 5 seconds - Instant Image DisplaySince it is a retrofit system, it is not necessary to replace x-ray generators, modify the office or redo in-office wirings. It is not associated with any hassles such as developing films or scanning the imaging plate with CR system. It takes seconds from x-ray exposure to image display. There is no more waiting for doctors and patients. The captured images are automatically stored in the computer for easier management of the patients' records.

High ResolutionMonochrome CCD Sensor

Scintillator

Carbon Plate

CCD Board

PC

NAOMI

USB cable

user
Stamp
Page 9: naomi_digital_x-ray_brochure_2010

Direct Digital Radiography CCD Imaging Sensor 07

Simply Replace the Film CassetteThe necessary equipments are only NAOMI sensor and a computer. The setup is to replace the film cassette with NAOMI sensor, and the office x-ray environment becomes digitized immediately. The doctors can continue to use their current x-ray generators.

Cost and Space SavingsSince films and chemicals are no longer required, it drastically reduces the running cost of the x-ray. It also liberates the dark room and plumbing system for the extra space in the office.

Film-based

film

None

chemicals

maintenance

NAOMI

No cassette preparation or film development. *NAOMI only requires electricity fee

user
Stamp
Page 10: naomi_digital_x-ray_brochure_2010

08

Operation

Digital Image Manipulation As simple as a digital camera

The NAOMI software (DICOM 3.0) provides easier methods to digital image manipulation: from magnification on the area of interest, length and angle measurement, contrast adjustment, negative-positive switchover, horizontal/vertical rotation, and side-by-side image layout for comparison. It provides more information on a single image to support diagnosis from various angles.

1. Enter the patient information.Create a folder by the chart number or patient name.

2. IrradiateThe existing x-ray generator in your clinic works with NAOMI.

Through the USB cable, the image data will be downloaded automatically.

Smooth Workflow

DICOM (Digital Image and Communication in Medicine)A communication standard developed by American College of Radiology (ACR) and National Electrical Manufacturers Association (NEMA) for medical image format acquired from CT, MRI, or digital x-ray.

X-Ray GeneratorNAOMI

USB Cable

IDPatient

user
Stamp
Page 11: naomi_digital_x-ray_brochure_2010

Direct Digital Radiography CCD Imaging Sensor 09

3. Instant Image AcquisitionThe captured image is instantly displayed on the monitor and automatically saved into the computer.

Through the LAN connection, the different terminals can access and share the captured images.

Manipulating the image is with an easy single click operation on the mouse. A doctor can start diagnosis instantly.

PC

LAN

Exam Room 1

Exam Room 2

Operation Room

33.4cm 131.2 o

Side-by-side Layout

It allows to display 2, 4, 9 and 16 images on the screen.

Negative/Positive Switchover

The image is displayed in both  negative and positive.

Annotation Another window opens with the image to measure and create an annotation.

Inversion/Rotation

It inverts or rotates the direction of the image.

Length Measurement

2 images Negative Inversion

RotationPositive4 images

Angle Measurement

Text Insertion

The length can be measured directly on the image.

The angle can be measured directly on the image.

Create a text box on the image to insert a comment.

Comment

user
Stamp
Page 12: naomi_digital_x-ray_brochure_2010
user
Stamp