naomi_digital_x-ray_brochure_2010
DESCRIPTION
naomi_digital_x-ray_brochure_2010TRANSCRIPT
From CR to DR .................................. 02
No.1 Share in DR Market .................... 04
Features .............................................. 06
Operation ........................................... 08
Optional Items .................................... 10
Specifications ...................................... 12
Support / After-Service ....................... 13
Contents
Densely aligned CCD sensors with our own unique technology
02
From CR to DRSince Dr. Roentgen discovered the x-ray in 1895, we used films to capture its light.As the market continues to move towards film-less radiology, the technology to detect x-ray has changed from film-base to CR and now to DR system.Densely aligned CCD sensors in NAOMI are now opening a new frontier in digital radiography to make the radiography process more effective and faster.
Direct Digital Radiography CCD Imaging Sensor 03
04
In 2007the No.1 Sharein DR Market* Researched by Yano Research Institute of Economy
Digital radiography system, NAOMI has honorably achieved the top share in DR market among private clinics in 2007. We are striving everyday to develop products to meet the customers' needs.
Direct Digital Radiography CCD Imaging Sensor 05
192 CCD sensors in the digital radiography system, NAOMI
Features
06
48 Megapixel High Image QualityNAOMI uses the maximum of 192 monochrome CCD sensors. By aligning them densely with our unique technology, NAOMI has achieved to capture the intense concentration of light and generates 48 megapixel image quality. The newly developed high-performance engine displays the image smoothly in 4096 gray scales (12 bit). A single image contains immense data information to be displayed, from soft tissue to osseous part in smoother and deeper levels of contrast.
From 5 seconds - Instant Image DisplaySince it is a retrofit system, it is not necessary to replace x-ray generators, modify the office or redo in-office wirings. It is not associated with any hassles such as developing films or scanning the imaging plate with CR system. It takes seconds from x-ray exposure to image display. There is no more waiting for doctors and patients. The captured images are automatically stored in the computer for easier management of the patients' records.
High ResolutionMonochrome CCD Sensor
Scintillator
Carbon Plate
CCD Board
PC
NAOMI
USB cable
Direct Digital Radiography CCD Imaging Sensor 07
Simply Replace the Film CassetteThe necessary equipments are only NAOMI sensor and a computer. The setup is to replace the film cassette with NAOMI sensor, and the office x-ray environment becomes digitized immediately. The doctors can continue to use their current x-ray generators.
Cost and Space SavingsSince films and chemicals are no longer required, it drastically reduces the running cost of the x-ray. It also liberates the dark room and plumbing system for the extra space in the office.
Film-based
film
None
chemicals
maintenance
NAOMI
No cassette preparation or film development. *NAOMI only requires electricity fee
08
Operation
Digital Image Manipulation As simple as a digital camera
The NAOMI software (DICOM 3.0) provides easier methods to digital image manipulation: from magnification on the area of interest, length and angle measurement, contrast adjustment, negative-positive switchover, horizontal/vertical rotation, and side-by-side image layout for comparison. It provides more information on a single image to support diagnosis from various angles.
1. Enter the patient information.Create a folder by the chart number or patient name.
2. IrradiateThe existing x-ray generator in your clinic works with NAOMI.
Through the USB cable, the image data will be downloaded automatically.
Smooth Workflow
DICOM (Digital Image and Communication in Medicine)A communication standard developed by American College of Radiology (ACR) and National Electrical Manufacturers Association (NEMA) for medical image format acquired from CT, MRI, or digital x-ray.
X-Ray GeneratorNAOMI
USB Cable
IDPatient
Direct Digital Radiography CCD Imaging Sensor 09
3. Instant Image AcquisitionThe captured image is instantly displayed on the monitor and automatically saved into the computer.
Through the LAN connection, the different terminals can access and share the captured images.
Manipulating the image is with an easy single click operation on the mouse. A doctor can start diagnosis instantly.
PC
LAN
Exam Room 1
Exam Room 2
Operation Room
33.4cm 131.2 o
Side-by-side Layout
It allows to display 2, 4, 9 and 16 images on the screen.
Negative/Positive Switchover
The image is displayed in both negative and positive.
Annotation Another window opens with the image to measure and create an annotation.
Inversion/Rotation
It inverts or rotates the direction of the image.
Length Measurement
2 images Negative Inversion
RotationPositive4 images
Angle Measurement
Text Insertion
The length can be measured directly on the image.
The angle can be measured directly on the image.
Create a text box on the image to insert a comment.