nanonics cryoview 2000™
DESCRIPTION
CryoView 2000™ Product Presentation. Nanonics CryoView 2000™. CryoView 2000™ Product Presentation. CryoView 2000 ™ Complete System. CryoView 2000™ Product Presentation. Modes of Operation. SPM modes: AFM contact AFM Intermittent contact mode Electrical Measurements NSOM - PowerPoint PPT PresentationTRANSCRIPT
SPM modes:• AFM contact• AFM Intermittent contact mode•Electrical Measurements•NSOM
Far Field Methods:• Standard Microscope Imaging• Fluorescence• Confocal
Modes of OperationCryoView 2000™
Product
Presentation
Schematic view of the CryoView 2000 ™ CryoView 2000™
Product
Presentation
1. Cryogenic Tip Scanner 2. Upper sapphire window3. Upper radiation screen4. Copper wire braids (heat changer)5. Cryostat6. Cold finger7. Radiation shield8. Bottom radiation screen9. Bottom sapphire window
10. XYZ positioner11. Transmission12. Stepper motor13. UHV Chamber14. UHV pump station15. Vacuum seal16. Removable chamber cover17. Cold sample mount18. Scanner hinge
CryoView 2000™
Product
Presentation
Easy Probe Placement
• probes pre mounted on a tuning fork• Easy magnetic placement of probe
Tuning Fork FeedbackCryoView 2000™
Product
Presentation
Unique tuning fork technology using a tapered and cantilevered NSOM or AFM probe.
Probes are premounted on the tuning fork.
Tuning fork Probe Glue
Standard NSOM/SPM Technology
Cylindrical Piezo
Probe
is not
Optical, microRaman or Electron/Ion Beam Friendly
neither from the top nor bottom
CryoView 2000™
Product
Presentation
The CryoView 2000 ™ Technology
Flat Scanner Probe
is
Optical, microRaman or Electron/Ion Beam Friendly
from the top and the bottom
CryoView 2000™
Product
Presentation
Nanonics 3D-Flatscan™
• Only 7 mm thick• 70 m X-Y-Z scan range • Central opening providing clear optical axis
CryoView 2000™
Product
Presentation
CryoView 2000™
Product
Presentation
High Vacuum System
Turbo pump system to reach high vacuum.
Ion pump system to maintain high vacuum without vibration.
CryoView 2000™
Product
Presentation
Cooling SystemLiquid Nitrogen or liquid Helium can be used for the cooling of the sample. The scanner is kept at a higher temperature, thus enabling a bigger scanrange.
1. Cryogenic Tip Scanner 4. Copper wire braids (heat changer)5. Cryostat6. Cold finger (arrows indicate coolant flow)7. Radiation shield8.Bottom radiation screen
CryoView 2000™
Product
Presentation
XYZ Sample Positioning System
The sample is mounted on a motorized XYZ-stage.
• Automated approach• Easy selection of imaged portion of the sample• Easy mounting of the sample on sample holder
CryoView 2000™
Product
Presentation
Illumination Sources
Illumination through the fiber using a Fiber Coupler• Nd-YAG Laser (532 nm)• Ar+-Laser (488 & 515 nm)• HeCd-Laser (325 nm)• Diode Laser (Vis – IR)• Femtosecond Laser
Fiber coupler and laser