NORTH BRYAN BAPTIST ACRES 1st INSTALLMENT LOT 1, BLOCK 1 REMAINDER OF 3.657 ACRES VOL. 1123, PG. 675 PLATTED
AutoCAD SHX Text
NORTH EARL RUDDER FWY (HIGHWAY 6 SOUTH)
AutoCAD SHX Text
15' LANDSCAPE EASEMENT VOL. 14688, PG. 26
AutoCAD SHX Text
25' WIDE UTILITY EASEMENT VOL. 3995, PG. 222
AutoCAD SHX Text
20' PUBLIC UTILITY EASEMENT VOL. 14688, PG. 26
AutoCAD SHX Text
15' ELECTRICAL EASEMENT VOL. 741, PG. 412
AutoCAD SHX Text
BRYAN INDEPENDENT SCHOOL DISTRICT NORTHWOOD SUBDIVISION 10th INSTALLMENT LOT 1, BLOCK 1 22.95 ACRES VOL. 958, PG. 731 PLATTED CURRENT ZONING: RD-5, RESIDENTIAL DISTRICT 5000
AutoCAD SHX Text
BRYAN DPS DISTRICT OFFICE LOT 1, BLOCK 1 6.487 ACRES VOL. 8678, PG. 279 PLATTED CURRENT ZONING: C-3, COMMERCIAL
AutoCAD SHX Text
NORTH BRYAN BAPTIST ACRES REMAINDER OF CALLED 3.657 ACRES VOL. 7108, PG. 80 CURRENT ZONING: C-3, COMMERCIAL
ARLEDGE LOT 1, BLOCK 1 3.65 ACRES CURRENT ZONING: C-3, COMMERCIAL
AutoCAD SHX Text
FUTURE PHASE
AutoCAD SHX Text
PHASE 1
AutoCAD SHX Text
NORTHVIEW BAPTIST CHURCH OF BRYAN, TEXAS, GERALD KIRKLAND and wife, BETTY KIRKLAND ACCESS EASEMENT VOL. 2422, PG. 182 VOL. 951, PG. 598 VOL. 883, PG. 149
AutoCAD SHX Text
BUILDING B FF = 339.25'
AutoCAD SHX Text
BUILDING A FF = 339.25'
AutoCAD SHX Text
FUTURE FIRE HYDRANT
AutoCAD SHX Text
PROPOSED DETENTION POND
AutoCAD SHX Text
JOB NO.:
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
K:\data\BCS\Proj_2019\E0633100_ARLEDGE SUBD - LOT 1 BLK 1 - STORAGE FAC\cadd\Arledge Mini Storage_05-2019_Overall Site Plan.dwg - July 3, 2019 - July 3, 2019July 3, 2019
AutoCAD SHX Text
PHASE ONE
AutoCAD SHX Text
BRYAN, TEXAS, BRAZOS COUNTY
AutoCAD SHX Text
TERRY ARLEDGE
AutoCAD SHX Text
C1.0
AutoCAD SHX Text
ARLEDGE STORAGE FACILITY
AutoCAD SHX Text
OVERALL SITE PLAN
AutoCAD SHX Text
SJH
AutoCAD SHX Text
SJH
AutoCAD SHX Text
SJH
AutoCAD SHX Text
E0633100
AutoCAD SHX Text
SCALE: 1"=40' (24"x36")
AutoCAD SHX Text
PROJECT LOCATION
AutoCAD SHX Text
SITE SPECIFIC NOTES: 1. PROJECT IDENTIFICATION: PROJECT IDENTIFICATION: PROJECT NAME: ARLEDGE STORAGE FACILITY ARLEDGE STORAGE FACILITY LOCATION: 2513 N. EARL RUDDER FREEWAY BRYAN, TEXAS 77803 LEGAL DESCRIPTION: ARLEDGE SUBDIVISION, LOT 1, BLOCK 1, MOSES BAINE SURVEY, A-3, BRYAN, BRAZOS COUNTY, TEXAS. ARLEDGE SUBDIVISION, LOT 1, BLOCK 1, MOSES BAINE SURVEY, A-3, BRYAN, BRAZOS COUNTY, TEXAS. ARLEDGE SUBDIVISION, LOT 1, BLOCK 1, MOSES BAINE SURVEY, A-3, BRYAN, BRAZOS COUNTY, TEXAS. 2. OWNER & DEVELOPED BY: OWNER & DEVELOPED BY: TERRY ARLEDGE P.O BOX 1460 ROCKDALE, TEXAS 77836 3. ARCHITECT INFORMATION: ARCHITECT INFORMATION: TO BE PROVIDED BY OWNER 4. TOTAL SITE AREA: 3.65 ACRES TOTAL SITE AREA: 3.65 ACRES 5. CURRENT USE: VACANT CURRENT USE: VACANT 6. PROPOSED USE & IMPROVEMENTS: COMMERCIAL, STORAGE FACILTIY PROPOSED USE & IMPROVEMENTS: COMMERCIAL, STORAGE FACILTIY 7. FLOODPLAIN: NO PORTION OF LOT 1, BLOCK 1 IS LOCATED WITHIN A FEMA DESIGNATED FLOODPLAIN PER FEMA FIRM PANEL NO FLOODPLAIN: NO PORTION OF LOT 1, BLOCK 1 IS LOCATED WITHIN A FEMA DESIGNATED FLOODPLAIN PER FEMA FIRM PANEL NO 48041C0185E EFFECTIVE 05-16-2012 8. BUILDING AREA: 10,500 SQ.FT (PER BUILDING) x 2 (PHASE 1 ONLY) BUILDING AREA: 10,500 SQ.FT (PER BUILDING) x 2 (PHASE 1 ONLY) 9. ALL PUBLIC AND PRIVATE UTILITY LINES & SERVICE LINES INCLUDING WATERLINES, SANITARY SEWER LINES, ELECTRIC LINES, ALL PUBLIC AND PRIVATE UTILITY LINES & SERVICE LINES INCLUDING WATERLINES, SANITARY SEWER LINES, ELECTRIC LINES, TV/CABLE, COMMUNICATIONS LINES, etc. SHALL BE UNDERGROUND INSTALLATIONS AND INSTALLED TO THE STANDARDS AND SPECIFICATIONS OF THE APPLICABLE GOVERNING AGENCY. 10. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING INSTALLATION OF ALL FRANCHISE & PRIVATE UTILITIES WITH THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING INSTALLATION OF ALL FRANCHISE & PRIVATE UTILITIES WITH EARTHWORK & PAVEMENT CONSTRUCTION. GENERAL CONTRACTOR IS RESPONSIBLE FOR FURNISHING & INSTALLING ANY NECESSARY UTILITY CONDUIT PRIOR TO SUBGRADE PREPARATION & PAVING OPERATION. GENERAL CONTRACTOR IS RESPONSIBLE FOR DETERMINATION OF UTILITY INSTALLATION ORDER. 11. ALL ELECTRIC & COMMUNICATIONS CONDUIT TO BE INSTALLED W/ PULL STRING AND END CAPS, WITH ENDS EXTENDING 2' BEYOND ALL ELECTRIC & COMMUNICATIONS CONDUIT TO BE INSTALLED W/ PULL STRING AND END CAPS, WITH ENDS EXTENDING 2' BEYOND PAVEMENT. MARK ENDS OF CONDUIT WITH PVC EXTENDING 3' ABOVE GROUND AS FOLLOWS: ELECTRIC-4" PAINTED RED; VERIZON/COMMUNICATIONS-3" PAINTED ORANGE; IRRIGATION-3" PAINTED BROWN, AND WATER-3" PAINTED BLUE. 12. ALL ROOF AND GROUND MOUNTED MECHANICAL EQUIPMENT SHALL BE SCREENED FROM VIEW FROM ANY PUBLIC RIGHT-OF-WAY OR ALL ROOF AND GROUND MOUNTED MECHANICAL EQUIPMENT SHALL BE SCREENED FROM VIEW FROM ANY PUBLIC RIGHT-OF-WAY OR RESIDENTIAL DISTRICT WITHIN 150' OF THE SUBJECT LOT. SUCH SCREENING SHALL BE COORDINATED WITH BUILDING ARCHITECTURE. 13. ITEMS CALLED AS "PROPOSED" OR "INSTALL" ARE TO BE FURNISHED AND INSTALLED BY THE CONTRACTOR INCLUSIVE OF ANY ITEMS CALLED AS "PROPOSED" OR "INSTALL" ARE TO BE FURNISHED AND INSTALLED BY THE CONTRACTOR INCLUSIVE OF ANY MATERIALS, LABOR, EQUIPMENT, AND OTHER REQUIREMENTS FOR A COMPLETE AND FUNCTIONING SITE ELEMENT. ALL ITEMS NECESSARY FOR PROPER COMPLETION OF THE WORK NOT SPECIFICALLY CALLED FOR OR SPECIFIED ON THE PLANS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND CONSIDERED SUBSIDIARY TO THE WORK. 14. ALL SIGNAGE IS TO BE PERMITTED SEPARATELY. ALL SIGNAGE IS TO BE PERMITTED SEPARATELY. 15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONTAINMENT AND PROPER DISPOSAL OF ALL LIQUID AND SOLID WASTE THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONTAINMENT AND PROPER DISPOSAL OF ALL LIQUID AND SOLID WASTE ASSOCIATED WITH THIS PROJECT. THE CONTRACTOR SHALL USE ALL MEANS NECESSARY TO PREVENT THE OCCURRENCE OF WIND BLOWN LITTER FROM THE PROJECT SITE. 16. DEMOLITION / CONSTRUCTION WASTE: SITE IS REQUIRED TO PROVIDE CONTAINMENT FOR WASTE PRIOR TO AND DURING DEMOLITION DEMOLITION / CONSTRUCTION WASTE: SITE IS REQUIRED TO PROVIDE CONTAINMENT FOR WASTE PRIOR TO AND DURING DEMOLITION / CONSTRUCTION. SOLID WASTE ROLL OFF BOXES AND/OR METAL DUMPSTERS SHALL BE PROVIDED BY CONTRACTOR WHEN NECESSARY. 17. CONCRETE WASHOUT AREA(S) TO BE OVER EXCAVATED AND WASTE MATERIAL REMOVED & DISPOSED OF OFF-SITE PRIOR TO CONCRETE WASHOUT AREA(S) TO BE OVER EXCAVATED AND WASTE MATERIAL REMOVED & DISPOSED OF OFF-SITE PRIOR TO PROJECT CLOSEOUT. FILL AREA BACK TO PLAN GRADE / EXISTING GROUND. 18. CONTRACTOR TO CONTACT TEXAS 811 48 HOURS PRIOR TO CONSTRUCTION. SPECIFIC ATTENTION SHOULD BE PAID TO FRANCHISE CONTRACTOR TO CONTACT TEXAS 811 48 HOURS PRIOR TO CONSTRUCTION. SPECIFIC ATTENTION SHOULD BE PAID TO FRANCHISE UTILITIES, VERIZON, GTE, ECT. SHOULD A CONFLICT ARISE BETWEEN THE PROPOSED CONSTRUCTION AND AN EXISTING UTILITY, CONTACT CEC 48 HOURS PRIOR TO CONSTRUCTION. 19. CONTRACTOR IS REQUIRED TO MAINTAIN AND RECORDS MUST BE KEPT WITH THE SWP3 AND MADE READILY AVAILABLE UPON CONTRACTOR IS REQUIRED TO MAINTAIN AND RECORDS MUST BE KEPT WITH THE SWP3 AND MADE READILY AVAILABLE UPON REQUEST TO THE PARTIES IN PART III.D.1 OF THE TPDES GENERAL PERMIT TXR150000. 20. ALL DISTURBED EARTH MUST BE 100% COVERED WITH ESTABLISHED GRASS OR GROUND COVER PRIOR TO CERTIFICATE OF ALL DISTURBED EARTH MUST BE 100% COVERED WITH ESTABLISHED GRASS OR GROUND COVER PRIOR TO CERTIFICATE OF OCCUPANCY.
AutoCAD SHX Text
THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF REVIEW ONLY UNDER THE AUTHORITY OF SHAUN HANSON P.E., LICENSE NO. 132894, ON 7/3/2019 IT IS NOT TO IT IS NOT TO BE USED FOR BIDDING OR CONSTRUCTION PURPOSES.
AutoCAD SHX Text
N EARL RUDDER FREEWAY (HWY 6)
AutoCAD SHX Text
N. TEXAS AVE.
AutoCAD SHX Text
N. F.M. 2818
AutoCAD SHX Text
MUMFORD RD.
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
###
AutoCAD SHX Text
PROPOSED
AutoCAD SHX Text
CONTOUR
AutoCAD SHX Text
BACK OF CURB/CONC.
AutoCAD SHX Text
ELECTRIC OVERHEAD
AutoCAD SHX Text
WATER LINE
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
WATER SERVICE
AutoCAD SHX Text
SANITARY SEWER LINE
AutoCAD SHX Text
FIRE HYDRANT ASSEMBLY
AutoCAD SHX Text
WATER METER
AutoCAD SHX Text
SETBACK LINE
AutoCAD SHX Text
FIRE LANE STRIPING
AutoCAD SHX Text
###
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
SANITARY SEWER CLEANOUT
AutoCAD SHX Text
ACCESS EASEMENT
AutoCAD SHX Text
PUBLIC UTILITY EASEMENT
AutoCAD SHX Text
PROPERTY LINE
AutoCAD SHX Text
LAY OF HOSE
AutoCAD SHX Text
FIRE COVERAGE RADII
AutoCAD SHX Text
SECURITY FENCE
AutoCAD SHX Text
PHASE 1 BOUNDARY
AutoCAD SHX Text
WOODVILLE RD.
AutoCAD SHX Text
SANITARY SEWER MANHOLE
AutoCAD SHX Text
SS
AutoCAD SHX Text
PUBLIC UTILITY EASEMENT
CALL BEFORE YOU DIG!
TEXAS ONE CALL PARTICIPANTS REQUEST
48 HOURS NOTICE BEFORE YOU DIG
DRILL, OR BLAST - STOP, CALL!
TEXAS ONE CALL SYSTEM
811
Feet
0 20 40
15
55
G
RE
EN
S P
RA
IR
IE
R
OA
D W
ES
T
CO
LL
EG
E S
TA
TIO
N, T
EX
AS
7
78
45
TE
L: (9
79
) 8
46
-6
21
2
FA
X: (9
79
) 8
46
-8
25
2
RE
GIS
TR
AT
IO
N #
F-2
21
4
DO
N D
UR
DE
N, IN
C
d.b
.a
. C
IV
IL
E
NG
IN
EE
RIN
G C
ON
SU
LT
AN
TS
SA
N A
NT
ON
IO
/ L
AR
ED
O
BR
YA
N / C
OL
LE
GE
S
TA
TIO
N
N
UTILITY DEPARTMENTS
BRYAN, TEXAS
DEVELOPMENT SERVICES
CITY OF BRYAN
KEVIN RUSSELL
(979) 209-5130
COMMUNICATIONS COMPANY
FRONTIER "VERIZON"
BRENDA VAJDAK
(979) 821-4770
GAS COMPANY
ATMOS GAS
LUIS CISNEROS
(979) 774-2542
COMMUNICATIONS COMPANY
SUDDENLINK
DAN AUGSBURGER
(979) 204-8263
ELECTRIC COMPANY
BTU
MEGAN CARLSON
(979) 821-5770
KEY NOTES
SITE
1 INSTALL 4" WIDE PARKING STRIPE (WHITE) - 9' X 20' TYPICAL SPACE DIMENSIONS UNLESSOTHERWISE NOTED ON C1.2.
2 RESERVED
3 INSTALL ADA PARKING SPACE SYMBOL PER ADA/TAS SPECIFICATIONS (TYPICAL).
4 INSTALL ADA LOADING ZONE STRIPING PER ADA/TAS SPECIFICATIONS (TYPICAL).
5 INSTALL POLE MOUNTED HANDICAP SIGN. LABEL WITH VAN ACCESSIBLE AS APPLICABLE. SEESHEET C5.0 FOR DETAIL.
6 INSTALL 6" CONCRETE WHEEL STOP AT ALL ADA SPACES (FACE OF WHEEL STOP TO BE 2' FROMEND OF STALL). SEE SHEET C5.0 FOR DETAIL.
7 INSTALL SECURITY FENCE. FENCE TO BE APPROVED BY OWNER PRIOR TO INSTALLATION. TYPICAL.
8 INSTALL ENTRANCE GATE. GATE TO BE APPROVED BY OWNER PRIOR TO INSTALLATION. TYPICAL.
9 INSTALL FLAG POLE AND FLAG POLE BASE. FLAG POLE TO BE APPROVED BY OWNER PRIOR TOINSTALLATION.
10 PROPOSED DUMPSTER ENCLOSURE. SEE DETAIL SHEET C5.0.
11 INSTALL CONSTRUCTION ENTRANCE PER BCS STANDARD DETAIL SWPP1-02 (25'X50')
12 CONCRETE WASH-OUT AREA
13 INSTALL TMUTCD STANDARD THROUGH LANE-USE ARROW PER TMUTCD FIGURE 3B-24A. TYPICAL.
14-18 RESERVED
PAVING
19 INSTALL 315LF OF 6" MONOLITHIC REINFORCED CURB AND GUTTER. SEE SHEET C5.0 FOR DETAIL.
31 FUTURE 12" X 6" TAPPING SLEEVE. SLEEVE TO BE FORD S70/S90.
32 FUTURE 6" PVC WATER LINE.
33 FUTURE 6" X 45DEG PVC BEND.
34 FUTURE 6" GATE VALVE.
35 FUTURE FIRE HYDRANT ASSEMBLY. SEE SHEET C5.1 FOR DETAIL.
36 INSTALL 12" X 1" TAPPING SLEEVE. SLEEVE TO BE FORD S70/S90. SEE BCS STANDARD DETAILW7-02 FOR METER CONNECTION DETAILS.
37 PROPOSED 1" WATER SERVICE METER TO BE SET BY BRYAN TEXAS UTILITIES. CONTRACTOR TOCOORDINATE METER INSTALLATION WITH CITY.
38 INSTALL 1" PVC WATER SERVICE LINE FROM NEW METER. COORDINATE WITH MEP PLANS FOREXACT CONNECTION AT BUILDING. OWNER TO PROVIDE MEP PLANS.
39 INSTALL 1" X 3/4" PVC TEE.
40 INSTALL 5LF OF 3/4" PVC IRRIGATION SERVICE LINE.
41 INSTALL 3/4" IRRIGATION METER TO BE SET BY BRYAN TEXAS UTILITIES. CONTRACTOR TOCOORDINATE METER INSTALLATION WITH CITY.
42 INSTALL BACKFLOW PREVENTOR ON IRRIGATION SERVICE LINE WITH 2' PVC STUB-OUT. CAP ANDMARK END WITH 4" PVC PIPE PAINTED BROWN AND EXTEND 4' ABOVE GROUND
45 225 LF VEHICLE LAY OF HOSE; CORRESPONDING R150' FIRE PROTECTION COVERAGE DEPICTEDFROM END OF LAY OF HOSE.
46 300 LF VEHICLE LAY OF HOSE; CORRESPONDING R150' FIRE PROTECTION COVERAGE DEPICTEDFROM END OF LAY OF HOSE.
47-52 RESERVED
SANITARY SEWER
53 EXISTING 8" PVC SANITARY SEWER LINE TO REMAIN.
54 INSTALL 8" X 6" PVC TAP SADDLE WYE.
55 INSTALL 6" X 45DEG PVC BEND.
56 INSTALL 6" PVC SANITARY SEWER SERVICE. COORDINATE WITH MEP PLANS FOR EXACTCONNECTION AT BUILDING. OWNER TO PROVIDE MEP PLANS.
57 INSTALL SANITARY SEWER LINE CLEAN-OUT. IF INSTALLED IN PAVEMENT, CLEANOUT TO BETRAFFIC RATED AND FLUSH IN NEW PAVEMENT.
58-63 RESERVED
DRAINAGE
64 PROPOSED DETENTION POND. SEE SHEET C3.0 FOR SPECIFIC GRADING INFORMATION.
65 INSTALL DETENTION OUTFALL STRUCTURE. SEE SHEET C5.1 FOR CONSTRUCTION DETAILS. SEESHEET C3.0 FOR GRADING INFORMATION.
66 INSTALL CONCRETE FLUME. SEE SHEET C5.1 FOR FLUME DETAIL. CONNECT FLUME AT DETENTIONOUTFALL.
67 INSTALL 4' WIDE CURB CUT.
68-74 RESERVED
ELECTRICAL
75 EXISTING OVERHEAD ELECTRICAL LINE TO REMAIN
76 EXISTING POWER POLE TO REMAIN.
77 RESERVED
78 RESERVED
79 RESERVED
80 INSTALL REINFORCED CONCRETE TRANSFORMER PAD, 10' X 10' MIN.
81 INSTALL TRANSFORMER, 1000KVA. SEE ELECTRICAL PLANS FOR MORE INFORMATION. OWNER TOPROVIDE MEP PLANS.
AutoCAD SHX Text
15' LANDSCAPE EASEMENT VOL. 14688, PG. 26
AutoCAD SHX Text
20' PUBLIC UTILITY EASEMENT VOL. 14688, PG. 26
AutoCAD SHX Text
15' ELECTRICAL EASEMENT VOL. 741, PG. 412
AutoCAD SHX Text
BRYAN INDEPENDENT SCHOOL DISTRICT NORTHWOOD SUBDIVISION 10th INSTALLMENT LOT 1, BLOCK 1 22.95 ACRES VOL. 958, PG. 731 PLATTED CURRENT ZONING: RD-5, RESIDENTIAL DISTRICT 5000
AutoCAD SHX Text
ARLEDGE LOT 1, BLOCK 1 3.65 ACRES CURRENT ZONING: C-3, COMMERCIAL
AutoCAD SHX Text
FUTURE PHASE
AutoCAD SHX Text
PHASE 1
AutoCAD SHX Text
BUILDING B FF = 339.25'
AutoCAD SHX Text
BUILDING A FF = 339.25'
AutoCAD SHX Text
FUTURE PHASE
AutoCAD SHX Text
NORTHVIEW BAPTIST CHURCH OF BRYAN, TEXAS, GERALD KIRKLAND and wife, BETTY KIRKLAND ACCESS EASEMENT VOL. 2422, PG. 182 VOL. 951, PG. 598 VOL. 883, PG. 149
AutoCAD SHX Text
SCALE: 1"=20' (24"x36")
AutoCAD SHX Text
JOB NO.:
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
K:\data\BCS\Proj_2019\E0633100_ARLEDGE SUBD - LOT 1 BLK 1 - STORAGE FAC\cadd\Arledge Mini Storage_05-2019_Site Plan.dwg - July 3, 2019 - July 3, 2019July 3, 2019
AutoCAD SHX Text
PHASE ONE
AutoCAD SHX Text
BRYAN, TEXAS, BRAZOS COUNTY
AutoCAD SHX Text
TERRY ARLEDGE
AutoCAD SHX Text
C1.1
AutoCAD SHX Text
ARLEDGE STORAGE FACILITY
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text
SJH
AutoCAD SHX Text
SJH
AutoCAD SHX Text
SJH
AutoCAD SHX Text
E0633100
AutoCAD SHX Text
THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF REVIEW ONLY UNDER THE AUTHORITY OF SHAUN HANSON P.E., LICENSE NO. 132894, ON 7/3/2019 IT IS NOT TO IT IS NOT TO BE USED FOR BIDDING OR CONSTRUCTION PURPOSES.