  • MVI56E-MNETC ControlLogix Platform

    Modbus TCP/IP Client Enhanced Communication Module

    February 3, 2013

    USER MANUAL

  • Your Feedback Please

    We always want you to feel that you made the right decision to use our products. If you have suggestions, comments, compliments or complaints about our products, documentation, or support, please write or call us.

    How to Contact Us

    ProSoft Technology

    5201 Truxtun Ave., 3rd Floor Bakersfield, CA 93309 +1 (661) 716-5100 +1 (661) 716-5101 (Fax) www.prosoft-technology.com support@prosoft-technology.com

    Copyright © 2013 ProSoft Technology, Inc., all rights reserved.

    MVI56E-MNETC User Manual

    February 3, 2013

    ProSoft Technology ® , ProLinx

    ® , inRAx

    ® , ProTalk

    ® , and RadioLinx

    ® are Registered Trademarks of ProSoft

    Technology, Inc. All other brand or product names are or may be trademarks of, and are used to identify products and services of, their respective owners.

    In an effort to conserve paper, ProSoft Technology no longer includes printed manuals with our product shipments. User Manuals, Datasheets, Sample Ladder Files, and Configuration Files are provided on the enclosed DVD, and are available at no charge from our web site: http://www.prosoft-technology.com/

    Content Disclaimer This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither ProSoft Technology nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Information in this document including illustrations, specifications and dimensions may contain technical inaccuracies or typographical errors. ProSoft Technology makes no warranty or representation as to its accuracy and assumes no liability for and reserves the right to correct such inaccuracies or errors at any time without notice. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us. No part of this document may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission of ProSoft Technology. All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to help ensure compliance with documented system data, only the manufacturer should perform repairs to components. When devices are used for applications with technical safety requirements, the relevant instructions must be followed. Failure to use ProSoft Technology software or approved software with our hardware products may result in injury, harm, or improper operating results. Failure to observe this information can result in injury or equipment damage. © 2013 ProSoft Technology. All rights reserved.

    http://www.prosoft-technology.com/

  • Important Safety Information

    North America Warnings

    A Warning - Explosion Hazard - Substitution of components may impair suitability for Class I, Division 2. B Warning - Explosion Hazard - When in hazardous locations, turn off power before replacing or rewiring modules.

    Warning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is known to be nonhazardous.

    C Suitable for use in Class I, Division 2 Groups A, B, C, and D, T5 Hazardous Locations or Non-Hazardous Locations.

    ATEX Warnings and Conditions of Safe Usage

    Power, Input, and Output (I/O) wiring must be in accordance with the authority having jurisdiction

    A Warning - Explosion Hazard - When in hazardous locations, turn off power before replacing or wiring modules. B Warning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is

    known to be non-hazardous. C These products are intended to be mounted in an IP54 enclosure. The devices shall provide external means to

    prevent the rated voltage being exceeded by transient disturbances of more than 40%. This device must be used only with ATEX certified backplanes.

    D DO NOT OPEN WHEN ENERGIZED.

    Electrical Ratings

     Backplane Current Load: 800 mA @ 5 Vdc; 3 mA @ 24 Vdc  Operating Temperature: 0°C to 60°C (32°F to 140°F)  Storage Temperature: -40°C to 85°C (-40°F to 185°F)  Shock: 30 g operational; 50 g non-operational; Vibration: 5 g from 10 Hz to 150 Hz  Relative Humidity 5% to 95% (without condensation)  All phase conductor sizes must be at least 1.3 mm (squared) and all earth ground conductors must be at least

    4mm (squared).

  • Agency Approvals and Certifications

    Agency

    RoHS

    CSA

    CE

    CSA CB Safety

    cULus

    GOST-R

    ATEX

    E183151 Class I Division 2 Groups A, B, C, and D

    Temp Code T5

    0°C to +60°C

    Atex

    Class I Division 2 Groups A, B, C, and D

    Temp Code T5

    0°C

  • MVI56E-MNETC ♦ ControlLogix Platform Contents Modbus TCP/IP Client Enhanced Communication Module User Manual

    ProSoft Technology, Inc. Page 5 of 183 February 3, 2013

    Contents

    Your Feedback Please ........................................................................................................................ 2 How to Contact Us .............................................................................................................................. 2 Important Safety Information ............................................................................................................... 3 Battery Life Advisory ........................................................................................................................... 4

    Guide to the MVI56E-MNETC User Manual 9

    1 Start Here 11

    1.1 What's New? ........................................................................................................... 12 1.2 System Requirements ............................................................................................. 13 1.3 Package Contents ................................................................................................... 14 1.4 Setting Jumpers ...................................................................................................... 15 1.5 Installing the Module in the Rack ............................................................................ 16 1.6 Importing the Sample Add-On Instruction ............................................................... 18 1.7 Creating a New RSLogix 5000 Project .................................................................... 19

    1.7.1 Creating the Module ................................................................................................ 20 1.7.2 Importing the Add-On Instruction ............................................................................ 23

    1.8 Connecting Your PC to the ControlLogix Processor ............................................... 34 1.9 Downloading the Sample Program to the Processor .............................................. 35

    2 Configuring the MVI56E-MNETC Module 37

    2.1 Installing ProSoft Configuration Builder .................................................................. 38 2.2 Using ProSoft Configuration Builder Software ........................................................ 39

    2.2.1 Upgrading from MVI56-MNETC in ProSoft Configuration Builder .......................... 39 2.2.2 Setting Up the Project ............................................................................................. 40 2.2.3 Setting Module Parameters ..................................................................................... 42 2.2.4 Module ..................................................................................................................... 43 2.2.5 MNET Servers ......................................................................................................... 46 2.2.6 MNET Client x ......................................................................................................... 48 2.2.7 MNET Client x Commands ...................................................................................... 51 2.2.8 Static ARP Table ..................................................................................................... 59 2.2.9 Ethernet Configuration ............................................................................................ 60

    2.3 Connecting Your PC to the Module ......................................................................... 61 2.3.1 Setting Up a Temporary IP Address ....................................................................... 61

    2.4 Downloading the Project to the Module .................................................................. 65 2.4.1 Using CIPconnect to Connect to the Module .......................................................... 66 2.4.2 Using RSWho to Connect to the Module ................................................................ 75

    3 Ladder Logic 77

    3.1 Controller Tags ........................................................................................................ 78 3.1.1 MVI56E-MNETC Controller Ta