mvi56e-mnet / mnetxt - prosoft technology mvi56e-mnet / mnetxt ♦ controllogix platform...

Download MVI56E-MNET / MNETXT - ProSoft Technology MVI56E-MNET / MNETXT ♦ ControlLogix Platform Contents Modbus

Post on 08-Apr-2020

1 views

Category:

Documents

0 download

Embed Size (px)

TRANSCRIPT

  • MVI56E-MNET / MNETXT ControlLogix™ Platform

    Modbus TCP/IP Interface Module

    March 3, 2020

    USER MANUAL

  • Start Here MVI56E-MNET / MNETXT ♦ ControlLogix™ Platform User Manual Modbus TCP/IP Interface Module

    Page 2 of 162 ProSoft Technology, Inc.

    Your Feedback Please

    We always want you to feel that you made the right decision to use our products. If you have suggestions, comments, compliments or complaints about our products, documentation, or support, please write or call us.

    How to Contact Us

    ProSoft Technology, Inc.

    +1 (661) 716-5100 +1 (661) 716-5101 (Fax) www.prosoft-technology.com support@prosoft-technology.com

    Copyright © 2019 ProSoft Technology, Inc. All rights reserved.

    MVI56E-MNET / MNETXT User Manual

    March 3, 2020

    ProSoft Technology ®, ProLinx ®, inRAx ®, ProTalk ®, and RadioLinx ® are Registered Trademarks of ProSoft Technology, Inc. All other brand or product names are or may be trademarks of, and are used to identify products and services of, their respective owners.

    ProSoft Technology® Product Documentation

    In an effort to conserve paper, ProSoft Technology no longer includes printed manuals with our product shipments. User Manuals, Datasheets, Sample Ladder Files, and Configuration Files are provided at: www.prosoft-technology.com

    For professional users in the European Union

    If you wish to discard electrical and electronic equipment (EEE), please contact your dealer or supplier for further information.

    Warning – Cancer and Reproductive Harm – www.P65Warnings.ca.gov

    https://www.prosoft-technology.com/

  • MVI56E-MNET / MNETXT ♦ ControlLogix™ Platform Start Here Modbus TCP/IP Interface Module User Manual

    ProSoft Technology, Inc. Page 3 of 162

    Warnings

    North America Warnings

    A Warning - Explosion Hazard - Substitution of components may impair suitability for Class I, Division 2.

    B Warning - Explosion Hazard - When in Hazardous Locations, turn off power before replacing or rewiring modules.

    C Warning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is known to be nonhazardous.

    D Class 2 Power

    ATEX Warnings and Conditions of Safe Usage:

    Power, Input, and Output (I/O) wiring must be in accordance with the authority having jurisdiction

    A Warning - Explosion Hazard - When in hazardous locations, turn off power before replacing or wiring modules.

    B Warning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous.

    C These products are intended to be mounted in an IP54 enclosure. The devices shall provide external means to prevent the rated voltage being exceeded by transient disturbances of more than 40%. This device must be used only with ATEX certified backplanes.

    D DO NOT OPEN WHEN ENERGIZED.

    Markings

    Hardware Ratings

     Backplane Current Load: 800 mA @ 5 VDC; 3 mA @ 24 VDC  Operating Temperature:

    For standard MVI56E modules: 0°C to 60°C (32°F to 140°F) For MVI56E XT (conformal coated): -25°C to 70°C (-13°F to 158°F)

     Storage Temperature: -40°C to 85°C (-40°F to 185°F)  Shock: 30 g operational; 50 g non-operational; Vibration: 5 g from 10 to 150 Hz  Relative Humidity: 5% to 95% (without condensation)  All phase conductor sizes must be at least 1.3 mm (squared) and all earth ground conductors

    must be at least 4mm (squared).  MVI56E XT module comes with conformal coating installed.

    Agency Approvals and Certifications

    Please visit our website: www.prosoft-technology.com

    http://www.prosoft-technology.com/

  • Start Here MVI56E-MNET / MNETXT ♦ ControlLogix™ Platform User Manual Modbus TCP/IP Interface Module

    Page 4 of 162 ProSoft Technology, Inc.

    Contents

    Your Feedback Please ................................................................................................... 2 How to Contact Us .......................................................................................................... 2 ProSoft Technology® Product Documentation ............................................................... 2 Warnings ........................................................................................................................ 3 Markings ......................................................................................................................... 3

    1 Start Here 7

    1.1 What's New? ......................................................................................... 8 1.2 System Requirements .......................................................................... 9 1.3 Package Contents .............................................................................. 10 1.4 Setting Jumpers .................................................................................. 11 1.5 Installing the Module in the Rack ........................................................ 12 1.6 Importing the Sample Add-On Instruction .......................................... 14 1.7 Creating a New RSLogix 5000 Project ............................................... 15

    1.7.1 Creating the Module ........................................................................... 16 1.7.2 Importing the Add-On Instruction ........................................................ 18

    1.8 Downloading the Sample Program to the Processor.......................... 28

    2 Configuring the MVI56E-MNET Module 29

    2.1 Installing ProSoft Configuration Builder .............................................. 29 2.2 Using ProSoft Configuration Builder Software .................................... 29

    2.2.1 Upgrading from MVI56-MNET in ProSoft Configuration Builder ........ 30 2.2.2 Setting Up the Project ......................................................................... 31 2.2.3 Setting Module Parameters ................................................................ 32 2.2.4 Module ................................................................................................ 34 2.2.5 MNET Client x ..................................................................................... 37 2.2.6 MNET Client x Commands ................................................................. 39 2.2.7 MNET Servers .................................................................................... 46 2.2.8 Static ARP Table ................................................................................ 49 2.2.9 Ethernet Configuration ........................................................................ 50

    2.3 Connecting Your PC to the Module .................................................... 51 2.3.1 Setting Up a Temporary IP Address ................................................... 52

    2.4 Downloading the Project to the Module .............................................. 55 2.4.1 Using CIPconnect to Connect to the Module ...................................... 56 2.4.2 Using RSWho to Connect to the Module ............................................ 66

    3 Ladder Logic 67

    3.1 Controller Tags ................................................................................... 67 3.1.1 MVI56E-MNET Controller Tags .......................................................... 68

    3.2 User-Defined Data Types (UDTs)....................................................... 69 3.2.1 MVI56(E)-MNET User-Defined Data Types ....................................... 69

    3.3 Using Controller Tags ......................................................................... 70 3.4 Controller Tag Overview ..................................................................... 71

    3.4.1 MNET.DATA ....................................................................................... 71 3.4.2 MNET.STATUS................................................................................... 74 3.4.3 MNET.CONTROL ............................................................................... 75 3.4.4 MNET.UTIL ......................................................................................... 76

  • MVI56E-MNET / MNETXT ♦ ControlLogix™ Platform Start Here Modbus TCP/IP Interface Module User Manual

    ProSoft Technology, Inc. Page 5 of 162

    4 Diagnostics and Troubleshooting 77

    4.1 LED Status Indicators ......................................................................... 78 4.1.1 Scrolling LED Status Indicators .......................................................... 78 4.1.2 Ethernet LED Indicators ...................................................................... 79 4.1.3 Non-Scrolling LED Status Indicators .................................................. 79 4.1.4 Troubleshooting .................................................................................. 80 4.1.5 Clearing a Fault Condition .................................................................. 80

    4.2 Using the Diagnostics Menu in ProSoft Configuration Builder ........... 81 4.2.1 Connecting to the Module's Webpage ................................................ 84 4.2.2 The Diagnostics Menu ........................................................................ 85 4.2.3 Monitoring Module Information ........................................................... 85 4.2.4 Monitoring Backplane Information ...................................................... 86 4.2

Recommended

View more >