CURRENT TRANSFORMERS
VOLTAGETRANSFORMERS
OURCERTIFICATES& STANDARTS
SOME OF OURREFERENCES
INDEX
MV CURRENT & VOLTAGE TRANSFORMERS
84 18 19
Advanced technology since 1980.
Developed with Elimsan’s perfect engineering, innovative technology and vast knowledge of its field, Measurement Transformers have IEC 61869 production standard and certified its quality and reliability after successfully passing KEMA and ICMET Lab tests. Measurement norms are at DIN German standards.
Plus, production is also available with ANSI NORM standards that are valid in USA, Canada stadards, AS Australia Stan-dards and the British Standards.
The main insulation material for Elimsan measurement transformer is Epoxy Resin. Through professional practices of Elimsan, the surface gets clean and ready for the process. The material is highly cohesive so it will never unstick, won’t change in time and show no structural change over the years.
Silica based plate irons are especially developed for substations and used in Elimsan MV Transformers to minimize magnetic loss with oriented electrons and to maximize magnetic features. Thus, while magnetic features are kept at the top level, product efficiency increases. Elimsan Transformer’s primary winding material is purified electrolytic copper with increased conductivity up to 99.9%. H class enamel coated copper used for secondary winding provides perfect isolation. Metal locking plates are used for fixing the product and Secondary Terminal Caps are used or safety. Primary Busbars are brass or copper according to the current. Elimsan makes no compromise on material quality, professional labor and R&D investments. Quality only increases day by day and Elimsan maintains its righteous competitive position at global markets.
Expert Engineering Reliable Products
Elimsan outmatches its rivals by being able to produce every product and component under the same roof. Metal Enclosed Modular Cells, Metal Clads, Gas Insulated Cells and all the components within these products are produced at Elimsan and also put on the market. Elimsan MV Transformers were designed many years ago for Elimsan products and through new technologies and experience, it gained a righteous seat at global markets.
Supplying top quality materials for its products, practicing meticulously, working flawlessly, developing innovative technology; Elimsan’s Medium Voltage Transformers have superior electrical and mechanical durability. Elimsan engineering and technology brings the capability to produce transformers that fits different projects. This satisfies custo-mer demands perfectly.
Elimsan Measurement Transformers Through its high quality materials and meticulous practices, Elimsan Measurement Transformers flawlessly measures and assesses the incoming current. the assessment is reflected at the counter and directly effects the cost. Elimsan MV Transformers performs very precise measurements so it minimizes your expenditures and increases your profitability.
Elimsan Protective Transformers It is crucial for protective transformers to be efficient and operate on full capacity so Elimsan’s innovative technology, per-fect engineering and high quality practices provide maximum safety to your systems, eliminates the burden of possible power cut costs and supports the cost saving of your enterprise.
ELIMSAN MV MEASUREMENT TRANSFORMERS
OGN
Other specifications available on request.
210
A
B
C
D
E
GH F
4 w w w . e l i m s a n . c o m
TECHNICAL VALUES
Highest voltage for equipment Um (rms) (kV)
Rated frequency (Hz)
Rated Primary Voltage Un[max.] (kV)
Secondary Voltage (V)
Rated burden in class 0.2-0.5-1.0 (VA)
Maximum rated burder for protection purpose in class 3P/6P (VA)
Thermal limiting current for earth fault detection winding (A)
Rated voltage factor [8h]
Weight (kg)
Test voltages (kV)
DIMENSIONS (mm)
Type
OGN 24 210
255
319
374
300
345
150
172.5
425
440
250
250
300
300
225
225OGN 36
A B C D E F G H
3624
70 / 17024 / 50
50, 60
36 / √324 / √3
100 / √3 or 110 / √3 or 120 / √3
5-10-15-20-30-45-60
100
6
1.9Un
5540
OGN36OGN24
5
OGN24 - OGN36VOLTAGE TRANSFORMERSStandard: IEC 61869-3, IEC 61869-5
24kV 36kVOGN24 OGN36
Advanced technology since 1980.
VOLTAGE TRANSFORMERS
OGN
Other specifications available on request.
210
A
B
CD
U/A
E
G
FH
6 w w w . e l i m s a n . c o m
TECHNICAL VALUES
Highest voltage for equipment Um (rms) (kV)
Rated frequency (Hz)
Rated Primary Voltage Un[max.] (kV)
Secondary Voltage (V)
Rated burden in class 0.2-0.5-1.0 (VA)
Maximum rated burder for protection purpose in class 3P/6P (VA)
Thermal limiting current for earth fault detection winding (A)
Rated voltage factor [8h]
Weight (kg)
Test voltages (kV)
2412 - 17,5
50 / 12528/75 - 38/95
50, 60
24 / √312 / √3 - 15 / √3
100 / √3 or 110 / √3 or 120 / √3
5-10-15-20-30-45-60
100
6
1.9Un
3425
EG24EG12
DIMENSIONS (mm)
Type
EG 12 148
178
220
280
280
300
140
150
350
360
148
178
270
280
125
150EG 24
A B C D E F G H
7
EG12 - EG24VOLTAGE TRANSFORMERSStandard: IEC 61869-3, IEC 61869-5
12kV 24kVEG12 EG24
Advanced technology since 1980.
VOLTAGE TRANSFORMERS
OGN
Other specifications available on request.
210
B
A CD
E
H F
G
62
120
4090
80 40
M12 M12120
M12
40
40
M12
8 w w w . e l i m s a n . c o m
TECHNICAL VALUES
Highest voltage for equipment Um (rms) (kV)
Rated frequency [Hz]
Maximum rated primary current [A]
Secondary rated current [A]
Rated short-time thermal current lth [kA]
Rated dynamic current ldyn
Weight (approx.) [kg]
Test voltages [kV]
3612 - 17,5
70/17028/75 - 38/95
50, 60
3000
1 or 5
60 (max. 1000xln)
2,5xlth
20 30
OAN36OAN12
DIMENSIONS (mm)
Type
OAN 12-2
OAN 36-1
OAN 36-3
190
220
230
184
200
245
262
361
366
256
360
391
238
245
280
238
240
315
119
122.5
140
119
120
157.5
365
390
390
365
390
390
148
250
250
148
250
250
270
300
300
270
300
300
125
225
225
128
225
225
OAN 12-3
OAN 36-2
OAN 36-4
A B C D E F G H
9
OAN12 - OAN36CURRENT TRANSFORMERSStandard: IEC 61869-2
12kV 36kVOAN12 OAN36
Advanced technology since 1980.
CURRENT TRANSFORMERS
OGN
Other specifications available on request.
210
A
B
DC
EG
FH
4062
=120
40
80 40
M12 =
90
M12=
120M12
40
= M12
10 w w w . e l i m s a n . c o m
TECHNICAL VALUES
Highest voltage for equipment Um (rms) (kV)
Rated frequency [Hz]
Maximum rated primary current [A]
Secondary rated current [A]
Rated short-time thermal current lth [kA]
Rated dynamic current ldyn
Weight (approx.) [kg]
Test voltages [kV]
50, 60
70/170
36
3000
1 or 5
60 (max. 1000xln)
2,5xlth
5242 46 56
OANB 36-2 OANB 36-3 OANB 36-7 OANB 36-9
DIMENSIONS (mm)
Type
OANB 36-2
OANB 36-7
255
255
239
255
384
386
386
386
320
450
290
370
160
225
145
185
430
430
430
430
250
250
250
250
300
300
300
300
225
225
225
225
OANB 36-3
OANB 36-9
A B C D E F G H
1 1
OANB36 SERIESCURRENT TRANSFORMERSStandard: IEC 61869-2
36kVOANB36 SERIES
Advanced technology since 1980.
CURRENT TRANSFORMERS
OGN
Other specifications available on request.
210
A
B
200
CD
P2P
1
EG
H F
40
3255
68
6832
32
60
M12
40
M12 M12
M12=
800A > In <= 1500A
=
> 1500A to 2500A
120
M12 M12= =120
=
In <= 800A CuIn <= 600A Pirinç
=120
12 w w w . e l i m s a n . c o m
TECHNICAL VALUES
Highest voltage for equipment Um (rms) (kV)
Rated frequency [Hz]
Maximum rated primary current [A]
Secondary rated current [A]
Rated short-time thermal current lth [kA]
Rated dynamic current ldyn
Weight (approx.) [kg]
Test voltages [kV]
50, 60
70/17028/75 - 38/95
12 - 17,5 24
3000
1 or 5
60 (max. 1000xln)
2,5xlth
3522 33 48
EA12, EA12-2 EA12-3 EA24, EA24-2 EA24-3
DIMENSIONS (mm)
Type
EA12
EA12-3
EA24-2
148
148
178
148
178
178
220
220
280
220
280
280
280
380
350
280
290
400
140
140
140
140
140
140
350
450
410
390
350
460
148
148
178
148
178
178
270
370
330
310
270
380
125
125
150
125
150
150
EA12-2
EA24
EA24-3
A B C D E F G H
13
EA12 - EA24 SERIESCURRENT TRANSFORMERSStandard: IEC 61869-2
Advanced technology since 1980.
12kV 24kVEA12 EA24
CURRENT TRANSFORMERS
OGN
Other specifications available on request.
210
ØA±1
F±1
G±1
ØB±1
5
E±1.
5C±1
.5
H±1
D±1
Ø11
SeconderTerminaller M5
Terminaller M8
S1 S2
P1
14 w w w . e l i m s a n . c o m
TECHNICAL VALUES
Rated primary current lpr [A]
Rated frequency [Hz]
Class rated burden [VA]
Accuracy class
Rated short-time thermal current (lth)
Insulation class
Rated secondary current ls [A]
40.......8000A
1A, 5A
50, 60
Acc. to customer requirement
Acc. to customer requirement
min. 100*lpr
E
DIMENSIONS (mm)
Type
EKAT-60/190-55
EKAT-60/190-115
EKAT-80/190-150
EKAT-80/190-95
EKAT-100/190-95
60
60
80
80
100
60
80
100
80
100
190
190
190
190
190
190
190
190
190
190
240
240
240
240
240
240
240
240
240
240
55
115
150
95
95
95
55
55
115
115
120
120
120
120
120
120
120
120
120
120
150
170
150
150
150
150
150
150
170
170
130
150
130
130
130
130
130
130
150
150
25
40
40
40
40
40
25
25
40
40
EKAT-60/190-95
EKAT-80/190-55
EKAT-100/190-55
EKAT-80/190-115
EKAT-100/190-115
A B C D E F G H
15
EKAT SERIESCURRENT TRANSFORMERSStandard: IEC 61869-2
Advanced technology since 1980.
CURRENT TRANSFORMERS
OGN
Other specifications available on request.
210
16 w w w . e l i m s a n . c o m
TECHNICAL VALUES
Highest voltage for equipment Um (rms) (kV)
Rated frequency [Hz]
Primary rated current [A]
Insulation class
Secondary rated current [A]
Rated short-time thermal current lth
Rated power-frequency withstand voltage [kV]
0.72
3
50, 60
3000
E
1 - 5
min. 100 x ln
INSTALLATION
CURRENT TRANSFORMERS 1 7
BUSHINGCURRENT TRANSFORMERSStandard: IEC 61869-2
Advanced technology since 1980.
S1
S2
min.
max.
max.
Etiket
QUALITY FOCUSED PRODUCTION
18 W w w . e l i m s a n . c o m
KEMATesting, Inspections & Certification organisation
ICMETResearch-Development and Testing National Institute for Electrical Engineering
CESIConsulting and testing services for elec- tricity sector playersEngineering
OHSASOccupational Health and Safety
IECInternational Standards and Con-formity Assessment for all electrical, electronic and related technologies
ISOTS EN ISO 9001 2008 TS EN ISO 17020 2012 TS EN ISO 17025 2010TS EN ISO 14001
19
Advanced technology since 1980
SOME OF OUR REFERENCES
TURKEY
GLOBAL
İnönü University Solar Power Plant
Enerjisa
Edaş
Asyaport
Myanmar
Azerbaijan
Kosovo
Vietnam
Colombia
Thailand
Sedaş
İçtaş
Teiaş projects
Qatar KAHRAMAA
Nigeria
Russia
Taiwan
Romania
Turkmenistan
Palestine
Metal Clad Switchgears
Metal Enclosed Switchgears
Metal Enclosed Switchgears
Metal Enclosed Switchgears & Gas Insulated Switchgears
Metal Clad Switchgears
Metal Clad Switchgears
Metal Enclosed Switchgears
Metal Enclosed Switchgears
Metal Enclosed Switchgears
Metal Enclosed Switchgears
Metal Enclosed Switchgears
Metal Clad Switchgears
Metal Clad Switchgears
Metal Clad Switchgears & Metal Enclosed Switchgears
Metal Enclosed Switchgears
Measurement Transformers
Measurement Transformers
Measurement Transformers
Measurement Transformers
Measurement Transformers
PARTNER
PARTNER
www. e l im s a n . c om
Bagdat Mahallesi. D100 Karayolu Cd. No:368 Kartepe - Kocaeli / TURKEYPhone : +90 262 375 2360Fax : +90 262 375 2322 / 30 21Email : [email protected]
Switchgear Equipment and Electromechanical Industry and Trade Inc.