mqc glycol dehydration unit - cdm > home · tomall aray te ouston tx cdmmcom mqc glycol...

6
20405 Tomball Parkway, Ste 700 | Houston, TX 77070 | www.CDMRM.com MQC Glycol Dehydration Unit Our stock MQC GDU size includes: 25 MMscfd Available in fleet on a limited basis include: A range of sizes between 1.5 MMscfd and 50 MMscfd CDM’s Modular Quik-Connect (MQC) design provides unparalleled value for producers by generating revenue sooner. Prefabricated in an ASME code shop, the CDM MQC design is complete with all piping, controls, instrumentation and electrical, and requires no concrete foundations. Reduced installation and demobilization time lessens total man hours per project thus decreasing total exposure to risk. This is why CDM has one of the best safety records in the industry. All CDM equipment is available for lease with full operation and maintenance service as well as bare rental, depending on customer needs. Value Through MQC Innovation More Efficient. Greater Flexibility. Higher Returns. Not all glycol dehydration units (GDU) are created equal. All remove unwanted water vapor from gas to prevent pipeline corrosion and line plugging (caused from hydrate formation), as well as reduce line capacity (caused from free water formation), but that’s where the similarities end. Ask us how the CDM Modular Quik-Connect (MQC) glycol dehydration unit design is superior to the competition. Safety CDM is committed to safety. We are proud to report our process & treating safety records. Year-end TRIR of zero since company inception in 2008 Zero recordable spills Zero recordable injuries Zero first aid injuries We Deliver What You Ask For! In-Stock Equipment Scalable Design Improved Project ROR 24/7 Service Availability Ease of Doing Business CDM’s Modular GDU design is Superior Innovation Our modular design allows for: Consistency in installation Quick response and rapid adjustments Adaptable to changing conditions Faster install and demobilization Increased safety and easier operation

Upload: dotu

Post on 10-May-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

20405 Tomball Parkway, Ste 700 | Houston, TX 77070 | www.CDMRM.com

MQC Glycol Dehydration Unit

Our stock MQC GDU size includes:25 MMscfd Available in fleet on a limited basis include: A range of sizes between 1.5 MMscfd and 50 MMscfd

CDM’s Modular Quik-Connect (MQC) design provides unparalleled value for producers by generating revenue sooner. Prefabricated in an ASME code shop, the CDM MQC design is complete with all piping, controls, instrumentation and electrical, and requires no concrete foundations. Reduced installation and demobilization time lessens total man hours per project thus decreasing total exposure to risk. This is why CDM has one of the best safety records in the industry.

All CDM equipment is available for lease with full operation and maintenance service as well as bare rental, depending on customer needs.

Value Through MQC InnovationMore Efficient. Greater Flexibility. Higher Returns. Not all glycol dehydration units (GDU) are created equal. All remove unwanted water vapor from gas to prevent pipeline corrosion and line plugging (caused from hydrate formation), as well as reduce line capacity (caused from free water formation), but that’s where the similarities end.

Ask us how the CDM Modular Quik-Connect (MQC) glycol dehydration unit design is superior to the competition.

Safety

CDM is committed to safety. We are proud to report our process & treating safety records. • Year-end TRIR of zero since company

inception in 2008• Zero recordable spills• Zero recordable injuries• Zero first aid injuries

We Deliver What You Ask For!

• In-Stock Equipment• Scalable Design• Improved Project ROR• 24/7 Service Availability

• Ease of Doing Business

CDM’s Modular GDU design is Superior Innovation Our modular design allows for: • Consistency in installation• Quick response and rapid adjustments• Adaptable to changing conditions• Faster install and demobilization• Increased safety and easier operation

CDM Resource Management LLC 20405 Tomball Parkway, Ste 700 Houston, TX 77070

281.376.2980 www.CDMRM.com

Glycol Solution 1200 Gallons Temporary Power (Generator)

N/A (fully pneumatic)

Glycol Make Up 500 gallon Regeneration Unit Skid

17,850 lb 20’-0” x 13’-3” x 12’-6”

Estimated Fuel Gas Consumption

30 MSCFD Glycol Contactor Skid

33,500 lb 32’-0” x 7’-0” x 10’-8”

Power Requirement: N/A (fully pneumatic) Glycol Contact Tower 29,172 lb 30’-0” x 4’-0” x 4’-0”

MQC Glycol Dehydration Unit

*Note: All items above are

At CDM, we believe time is money and safety is priceless.

MQC GDU consists of: Front End Skid

• Inlet Horizontal Coalescing Filter Separator

• Contact Tower• Horizontal After ScrubberBack End Skid

• Regeneration UnitBtEX Unit (optional; additional charge)

Pictured left: 50 MMscfd

20405 Tomball Parkway, Ste 700 | Houston, TX 77070 | www.CDMRM.com

BTEX Unit

BTEX Unit BTEX units are used to hold the toxic liquid elements (benzene, toluene, ethylbenzene, xylene) removed from natural gas.

BTEX are usually paired with a Dehydrator and should be considered additions to the treating final solution.

Safety

CDM is committed to safety. We are proud to report our process & treating safety records. • Year-end TRIR of zero since company

inception in 2008• Zero recordable spills• Zero recordable injuries• Zero first aid injuries

We Deliver What You Ask For!

• In-Stock Equipment• Scalable Design• Improved Project ROR• 24/7 Service Availability

• Ease of Doing Business

Emissions Controls are Growing.

The Clean Air Act limits the amounts of heavy hydrocarbons (a.k.a. Volatile Organic Compounds) which may be emitted from a facility to 250 tons per year. Aromatic compounds such as benzene are further classified as Hazardous AirPollutants and are limited to 25 tons per year total aromatics and 10 tons per year of any individual aromatic.

Eventually BTEX units will become mandatory.

20405 Tomball Parkway, Ste 700 | Houston, TX 77070 | www.CDMRM.com

MQC T-Ox (Thermal Oxidizer)

Our stock MQC Thermal Oxidzer sizes include:T-Ox 500 MSCFD (paired with our 100 GPM Amine plant)T-Ox 3000 MSCFD (paired with our 400 GPM Amine plant)

CDM’s Modular Quik-Connect (MQC) design is skid mountd and provides unparalleled value for producers by generating revenue sooner. Prefabricated in an ASME code shop, the CDM MQC design is complete with all piping, controls, instrumentation and electrical, and requires no concrete foundations. Reduced installation and demobilization time lessens total man hours per project thus decreasing total exposure to risk. This is why CDM has one of the best safety records in the industry.

Value Through MQC InnovationMore Efficient. Greater Flexibility. Higher Returns. Not all Thermal Oxidizers are created equal. Ours are a robust heavy duty system that enable 99.9% (DRE) destruction removal efficiency of unwanted chemicals in our Amine Plant Vent Gas.

Ask us how the CDM Modular Quik-Connect (MQC) Thermal Oxidizer design is superior to the competition. Safety

CDM is committed to safety. We are proud to report our process & treating safety records. • Year-end TRIR of zero since company

inception in 2008• Zero recordable spills• Zero recordable injuries• Zero first aid injuries

We Deliver What You Ask For!

• In-Stock Equipment• Scalable Design• Improved Project ROR• 24/7 Service Availability

• Ease of Doing Business

1DAY

INSTALL

CDM’s Modular T-Ox design is Superior Innovation Our modular design allows for: • Consistency in installation• Quick response and rapid adjustments• Adaptable to changing conditions• Faster install and demobilization• Increased safety and easier operation

All CDM equipment is available for lease with full operation and maintenance service as well as bare rental, depending on customer needs.

What We Need To Know To Quote: • Vent Gas Composition• Vent Gas Flow Rate• Temperature• Pressure

CDM Resource Management LLC 20405 Tomball Parkway, Ste 700 Houston, TX 77070

281.376.2980 www.CDMRM.com

MQC T-Ox (Thermal Oxidizer)

*Note: All items above are estimates

MRW design

Weight 16,550 lbDimensions (foot print)

30-0” x 8-0” x 7’-0”

MQC T-Ox consists of: • Vertical Self Supported Stack• Carbon Steel Firebox• Flanged Sight Port• UV Flame Scanner Port• Flanged Waste Gas Inlet• Thermocouple connections com-

plete with thermocouples• Special Alloy Rain Cap/Refrac-

tory Protector• Pilot Burner• Auxiliary Gas Burner • Waste Gas Injector – Control/Ignition System – Pilot Monitoring Device

At CDM, we believe time is money and safety is priceless.

T-Ox

500

QTI design

Weight 13,500 lbDimensions (foot print)

8-0” x 8’-0” x 31-0”

Weight 33,550 lbT-Ox

3000

T-Ox

500

MRW design QTI design

20405 Tomball Parkway, Ste 700 | Houston, TX 77070 | www.CDMRM.com

Natural Gas Driven Generator

Our stock NGD Generator size includes:350 KW (Est. weight: 35,000 lb; Est. Dimensions: 20’-4” x 8’-0”)

CDM Resource Management LLC provide an electrical backup solution to power Amine Plants. Designed with speed to market advantage, all solutions are built for greater flexibility in the field to customize and adapt to the customer’s changing needs, including quicker demobilization and reduced cost. Reduced time and personnel on location also increases safety. This is why CDM has one of the best safety records in the industry.

All CDM equipment is available for lease with full operation and maintenance service as well as bare rental, depending on customer needs.

CDM’s Superior Innovation.More Efficient. Greater Flexibility. Higher Returns. Not all natural gas driven generators (NGD) are created equal. All offer our customers in remote areas a cheaper alternative to the diesel powered generators.

Ask us how the CDM Natural Gas driven generator is superior to the competition.

Safety

CDM is committed to safety. We are proud to report our process & treating safety records. • Year-end TRIR of zero since company

inception in 2008• Zero recordable spills• Zero recordable injuries• Zero first aid injuries

We Deliver What You Ask For!

• In-Stock Equipment• Scalable Design• Improved Project ROR• 24/7 Service Availability

• Ease of Doing Business

Components Include:

• Engine Driver• Generator• Control Panel• Steel Enclosure• Fuel Filter

• Catalytic Converter/

Air Fuel Ratio Controller

• Radiator and Fan