Asbestos Register(Hazardous Materials and Risk Assessment)
School: Miller Technology High School (8394)
Region: South Western Sydney AMU
State Electorate: Liverpool
Local Government Area: Liverpool
Last Reviewed By: Greencap 26-AUG-2014
Last Revised By:
Historical Fibro In Grounds Investigations/Events No
No previous investigations have been recorded against the school. However, asbestos containing materialsmaybe present in grounds from time to time and caution must be exercised prior to any groundsdisturbance.
Miller Technology High School (8394) 9/09/2020 1/29
Preface to Asbestos RegisterLimitationsAsbestos Registers established (first surveyed 2007/08) and maintained for the Department of Education (DoE) are limited in extent, in that:
1. All inspections and surveys of materials and finishes in DoE facilities are non-disturbance, with2. Samples undertaken by hygienist to determine whether a sample is an Asbestos Containing Material (ACM),3. The hygienist may apply a single sample to like materials within a space and adjoining spaces, but not normally between buildings,4. Successive inspections have reduced any inconclusive records such as ‘assumed asbestos’ in difficult to access areas, by undertaking additional sampling
with lifting devices.5. In compliance with WHS Act 2011 and WHS Regulations 2017, additional inspections have been undertaken in ceiling spaces and sub-floor areas where
access is possible.Where the ground floor is slab on ground, no inspection is made beneath the slab.Where fibro fragments (ACM taken for sampling) are located in ceiling spaces or sub floor voids air monitoring is normally undertaken at time ofsampling, and clearance undertaken as soon as practicable.
6. No attempt has been made to identify any ACM that is hidden from view or encapsulated withinAny wall cavitySub floor area, particularly formwork for slabs in/on ground,Services (that may use ACM) such as: pipe lagging, asbestos cement pipes, flues.
7. All known ACM in Grounds (Fibro in Grounds) is made available in associated site specific asbestos management plans in DoE electronic files.Notwithstanding information provided, ACM may be present in grounds from time to time and caution must be exercised prior to any grounds disturbance.
Use of the Asbestos RegisterPrior to any disturbance works being undertaken in a building to which this asbestos register applies it will be necessary to confirm the extent of any ACM by adisturbance investigation:
If the building was built prior to 2003If any ACM has been identified in the Asbestos Register for the building.
Update of Asbestos RegistersAsbestos Register Data is updated regularly by the DoE Hygienist Panel via the Online Asbestos Register Tool (Managed by Business Systems, SchoolInfrastructure NSW). Internal users can view the latest edition of the Asbestos Register in the AMS.
Please note: The Department's external website may not contain the latest revision of the Asbestos Register.
Notes 1: VermiculiteDuring 2018/19, all vermiculite occurrences in DoE schools identified in 2007/08, were ‘composite tested’ in accordance with a safe work NSW agreedprocedure. This required multiple testing of all vermiculite occurrences.During the period 2007/08 to 2018/19, some vermiculite has been over sheeted and a warning is indicated for schools where this has happened.
Note 2: DoE website link for information is here:https://www.schoolinfrastructure.nsw.gov.au/about-us/workingwithus/schools-asbestos-register.html https://education.nsw.gov.au/about-us/strategies-and-reports/our-reports-and-reviews/schools-asbestos-register
Note 3: Material Condition AssessmentThe material condition assessment descriptors from Section 3 of the Asbestos Management Plan (AMP) is extracted below. Please read the AMP in its entirety forfurther information.
3.3.2.1 Material condition assessment
The OART records the material condition of identified ACM in the following format:
Rating Description
Good condition (1) For non-friable asbestos that is sealed and has no visible damage. This primarily related to asbestos cement (AC) sheet and vinyl tiles
Minimal damage (2) For non-friable asbestos that has a very small amount of damage, eg hairline cracks.
Some damage /unsealed (3)
For non-friable asbestos with significant breakage or several small areas where material has been damaged, revealing loose asbestosfibres. Non-friable asbestos that is unsealed.
Poor condition (4) For non-friable asbestos that has extensive damage. Visible asbestos debris
Friable asbestos (5) Any occurrence of friable asbestos
Miller Technology High School (8394) 9/09/2020 2/29
Product Material Description Extent Location MaterialCondition
RiskStatus
RemediationPriority
Result
B00A - Administration/General Learning - 1965 - Brick/BlockExterior
Underfloor Voids -Slab on Ground
Non Accessible Area
External WallStructure
Compressed AC Sheet 40 East & West GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos) , Amosite(brown asbestos) , Crocidolite (blueasbestos)
Ceiling Voids - FlatRoof
Non Accessible Area
Interior
B00A - R0001 - Public Reception - 26.26 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0002 - Administration - Clerical - 33.29 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0004 - Administration - Clerical - 15.42 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0006 - Cleaning Store - Distributed - 4.35 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0008 - Clinic - 8.36 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0009 - Office/Store - 8.35 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0010 - Staff - Toilet - 4.06 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0011 - Staff - Toilet - 4.06 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0012 - Administration - Clerical - 8.37 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0016 - Plant - .88 m2
No Asbestos
B00A - R0017 - Plant - .9 m2
No Asbestos
B00A - R0018 - Computer Learning Space - 59.48 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0019 - Printing/Photocopying - 24.05 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Miller Technology High School (8394) 9/09/2020 3/29
B00A - R0020 - Commonroom - 66.52 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0021 - Archive Store - 21.05 m2
CeilingStructures/Linings
Vermiculite
Floor CoveringsRes/Textile
Vinyl Sheet
B00A - R0024 - Principal Office - 19.75 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0025 - General Storeroom - 2.99 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0026 - Staff - Toilet - 3.16 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0027 - Toilets-Boys - 13.07 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0028 - Toilets-Girls - 18.48 m2
CeilingStructures/Linings
Vermiculite
B00A - R0029 - Cleaning Supplies Store - 16.13 m2
No Asbestos
B00A - R0030 - Handwashing Facilities - .22 m2
No Asbestos
B00A - R0031 - Coffee Kiosk - 54.76 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0032 - Deputy Principal Office - 19.25 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0033 - Tea Room - 2.94 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0034 - Movement - 15.42 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0035 - Student Waiting - 13.18 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0036 - Deputy Principal Office - 27.06 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0037 - Tea Room - 2.01 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Miller Technology High School (8394) 9/09/2020 4/29
B00A - R0038 - General Storeroom - 10.14 m2
No Asbestos
B00A - R0039 - Handwashing Facilities - .23 m2
No Asbestos
B00A - R0040 - External Stairs - 1.12 m2
No Asbestos
B00A - R0041 - External Stairs - 1.16 m2
No Asbestos
B00A - R0043 - External Movement - 241.19 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R0044 - Lift - 2.34 m2
No Asbestos
B00A - R0045 - Plant - 1.11 m2
No Asbestos
B00A - R1001 - General Learning Space - 53.89 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R1002 - Resources Store - 12.57 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 12m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00A - R1003 - Office/Store - 13.03 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 12m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00A - R1004 - Computer Learning Space - 73.4 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 74m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00A - R1005 - Staff Study - 9.06 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 10m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00A - R1006 - Staff Study - 9 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 9m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00A - R1007 - Resources Store - 7.26 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Miller Technology High School (8394) 9/09/2020 5/29
Note: No inspection of live electrical installation
Note: No inspection of live electrical installation
Floor CoveringsRes/Textile
Vinyl Tiles 8m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00A - R1008 - Interview/Office - Type 1 - 11.73 m2
Floor CoveringsRes/Textile
Vinyl Tiles 12m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R1009 - Student Lounge - 39.47 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 40m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00A - R1010 - Art Learning Space - 72.5 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 74m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00A - R1011 - General Storeroom - 39.4 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 37m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00A - R1012 - Staff Study - 40.27 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 37m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00A - R1013 - Distribution Board Cupboard - .91 m2
No Asbestos
B00A - R1014 - General Learning Space - 59.09 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles (Under FloorCovering/Carpet)
59.79m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00A - R1018 - Distribution Board Cupboard - .9 m2
No Asbestos
B00A - R1021 - Seminar - 106.71 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles (Under FloorCovering/Carpet)
106.71m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00A - R1022 - General Storeroom - 9.89 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R1023 - Student Waiting - 23.6 m2
Miller Technology High School (8394) 9/09/2020 6/29
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R1024 - Deputy Principal Office - 10.95 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R1025 - Deputy Principal Office - 13.38 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00A - R1026 - Handwashing Facilities - .23 m2
No Asbestos
B00A - R1027 - External Stairs - 5.99 m2
No Asbestos
B00A - R1028 - Handwashing Facilities - .23 m2
No Asbestos
B00A - R1029 - External Stairs - 5.76 m2
No Asbestos
B00A - R1031 - External Movement - 128.46 m2
No Asbestos
B00B - Technological & Applied Studies/Music - 1965 - Brick/BlockExterior
Underfloor Voids -Slab on Ground
Non Accessible Area
Ceiling Voids - FlatRoof
Non Accessible Area
External WallStructure
Compressed AC Sheet 55 East & West GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos) , Amosite(brown asbestos) , Crocidolite (blueasbestos)
Interior
B00B - R0003 - Resources Store - 26.95 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00B - R0004 - Food Technology L.S. - 72.74 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 73m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R0005 - Preparation - Materials - 12.96 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 13m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R0006 - Pantry - 12.61 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 13m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R0011 - General Learning Space - 53.67 m2
Floor CoveringsRes/Textile
Vinyl Tiles 54m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
Miller Technology High School (8394) 9/09/2020 7/29
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00B - R0012 - Resources Store - 3.11 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00B - R0013 - Staff - Toilet - 3.58 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 4m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R0014 - Staff - Toilet - 3.7 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 4m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R0015 - Staff Study - 32.51 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 33m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R0016 - Resources Store - 15.87 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 16m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R0018 - External Movement - 148.31 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00B - R0019 - Laundry - 4.68 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00B - R0020 - Food Technology L.S. - 97.64 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 98m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R0021 - Materials Workshop - Type 3 - 52.51 m2
CeilingStructures/Linings
Vermiculite
B00B - R0022 - Wood Technology L.S. - 59.01 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00B - R0023 - Dust Extraction Space - 10.04 m2
No Asbestos
Miller Technology High School (8394) 9/09/2020 8/29
B00B - R0024 - General Storeroom - 7.01 m2
CeilingStructures/Linings
Vermiculite
B00B - R0025 - Resources Store - 22.35 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 10m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R0026 - Plant - .92 m2
No Asbestos
B00B - R0027 - Handwashing Facilities - .21 m2
No Asbestos
B00B - R0028 - Cleaning Store - Distributed - 7.58 m2
No Asbestos
B00B - R0029 - Plant - .9 m2
No Asbestos
B00B - R0030 - Handwashing Facilities - .2 m2
No Asbestos
B00B - R0031 - External Stairs - 3.48 m2
No Asbestos
B00B - R0032 - External Stairs - 3.46 m2
No Asbestos
B00B - R0033 - Kiln Space - 22.08 m2
No Asbestos
B00B - R0034 - Metal Technology L.S. - 88.75 m2
No Asbestos
B00B - R0035 - Welding Area - 3.76 m2
No Asbestos
B00B - R0036 - Welding Area - 3.74 m2
No Asbestos
B00B - R0037 - Welding Area - 3.82 m2
No Asbestos
B00B - R0038 - Outdoor Workshop - 69.67 m2
No Asbestos
B00B - R0039 - External Movement - 37.48 m2
No Asbestos
B00B - R0040 - Lift - 2.37 m2
No Asbestos
B00B - R0041 - Plant - 1.05 m2
No Asbestos
B00B - R0042 - External Movement - 22.76 m2
No Asbestos
B00B - R0043 - Covered Vehicle Area/Porte Cochere - 24.26 m2
No Asbestos
B00B - R1003 - Music Store - 6.11 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 6.46m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R1004 - Practice/Seminar - 6.28 m2
Miller Technology High School (8394) 9/09/2020 9/29
Note: No inspection of live electrical installation
Note: No inspection of live electrical installation
Floor CoveringsRes/Textile
Vinyl Tiles 7m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00B - R1005 - Music Learning Space - 67.06 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 67m2 West FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R1006 - Distribution Board Cupboard - .9 m2
No Asbestos
B00B - R1007 - Music Learning Space - 59.24 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 59.15m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R1008 - Staff Study - 26.07 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 26.24m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R1009 - Art Learning Space - 52.94 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 53m2 West FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R1011 - Resources Store - 10.26 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 11m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R1012 - Distribution Board Cupboard - .9 m2
No Asbestos
B00B - R1013 - Resources Store - 8.86 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 9m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R1014 - Resources Store - 4.46 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 5m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R1015 - Music Learning Space - 50.6 m2
Miller Technology High School (8394) 9/09/2020 10/29
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00B - R1016 - Project Store - Type 1 - 16.26 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00B - R1019 - Wood Technology L.S. - 69.21 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 20m2 West FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R1020 - Wood Technology Bay - 52.36 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00B - R1021 - Wood Technology L.S. - 86.19 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00B - R1022 - Art Learning Space - 52.8 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 52.8m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R1023 - Project Store - Type 1 - 21.58 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 21.58m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R1024 - Handwashing Facilities - .23 m2
Wall LiningsInternal
Flat AC Sheeting 0.23m2 East GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R1025 - External Stairs - 5.67 m2
No Asbestos
B00B - R1026 - Handwashing Facilities - .24 m2
Wall LiningsInternal
Flat AC Sheeting 0.24m2 East GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00B - R1027 - External Stairs - 5.61 m2
No Asbestos
B00B - R1028 - External Movement - 140.34 m2
No Asbestos
B00B - R1029 - External Movement - 33.91 m2
No Asbestos
B00C - Pupil Facilities/Physical Education - 1965 - Brick/BlockExterior
Underfloor Voids -Slab on Ground
Non Accessible Area
Ceiling Voids - FlatRoof
Non Accessible Area
Interior
B00C - R0003 - Machine Storage - 7.14 m2Miller Technology High School (8394) 9/09/2020 11/29
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0004 - Cleaning Store - Distributed - 5.59 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0005 - Student Canteen - 54.14 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0006 - Staff - Toilet - 3.19 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0007 - Pantry - 3.66 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0008 - Sport Equipment Store - 14.42 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0009 - Sport Equipment Store - 18.53 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0010 - Sport Equipment Store - 2.02 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0011 - Sport Equipment Store - 15.82 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0012 - Cleaning Store - Distributed - 1.42 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0013 - Sport Equipment Store - 5.25 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0015 - General Storeroom - 6.71 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0017 - External Movement - 67.81 m2
No Asbestos
B00C - R0018 - Materials Store - 58.73 m2
No Asbestos
B00C - R0019 - Movement - 17.71 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0020 - External Movement - 7.24 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Miller Technology High School (8394) 9/09/2020 12/29
B00C - R0021 - Multi-Purpose Space - 317.75 m2
No Asbestos
B00C - R0022 - Movement - 8.83 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0023 - Sport Equipment Store - 8.86 m2
No Asbestos
B00C - R0024 - Stairs - 4.29 m2
No Asbestos
B00C - R0025 - Movement - 8.85 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00C - R0026 - General Storeroom - 9.2 m2
No Asbestos
B00C - R0027 - Stairs - 4.11 m2
No Asbestos
B00C - R0028 - General Assistants - 37.07 m2
No Asbestos
B00C - R0029 - General Assistants - 8.29 m2
No Asbestos
B00C - R1001 - Cleaning Store - Distributed - 7.09 m2
Wall LiningsInternal
Flat AC Sheeting
B00C - R1006 - Cleaning Store - Distributed - 7.05 m2
No Asbestos
B00C - R1007 - Movement - 8.56 m2
No Asbestos
B00C - R1008 - Movement - 8.59 m2
No Asbestos
B00C - R1009 - Stairs - 14.13 m2
No Asbestos
B00C - R1010 - Toilets-Boys - 32.98 m2
Partition Walls(Cubicles)
Compressed AC Sheet
B00C - R1011 - Plant - 2.33 m2
No Asbestos
B00C - R1012 - Plant - 2.38 m2
No Asbestos
B00C - R1013 - Change - 35.07 m2
No Asbestos
B00C - R1014 - Plant - 3.63 m2
No Asbestos
B00C - R1015 - Stairs - 14.06 m2
No Asbestos
B00C - R1016 - Toilets-Girls - 36 m2
Partition Walls(Cubicles)
Compressed AC Sheet
B00C - R1017 - Plant - 2.37 m2
No Asbestos
B00C - R1018 - Change - 36.02 m2
Partition Walls(Cubicles)
Compressed AC Sheet
Miller Technology High School (8394) 9/09/2020 13/29
B00C - R1019 - Plant - 2.38 m2
No Asbestos
B00D - Science Learning/General Learning - 1965 - Brick/BlockExterior
External WallStructure
Compressed AC Sheet 60 East & West GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos) , Amosite(brown asbestos) , Crocidolite (blueasbestos)
Underfloor Voids -Slab on Ground
Non Accessible Area
Ceiling Voids No Asbestos Found
Interior
B00D - R0001 - Laboratory L.S. - 92.78 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Furniture / Fixtures Flat AC Sheeting 2 North, Middle portion GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R0004 - Laboratory L.S. - 92.76 m2
Furniture / Fixtures Compressed AC Sheet 2 North, Middle portion GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00D - R0005 - Staff Study - 65.1 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00D - R0006 - General Storeroom - 11.37 m2
No Asbestos
B00D - R0008 - Staff - Toilet - 4.44 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 5m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R0009 - Cleaning Store - Distributed - 3.44 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 4m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R0010 - Staff - Toilet - 4.43 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 5m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R0012 - Preparation - Science - 19.11 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 20m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
Miller Technology High School (8394) 9/09/2020 14/29
Plant / Equipment -Fume Cupboard
Flat AC Sheeting 10 East, West, Middleportion, Variablepositions
GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R0013 - Resources Store - 6.61 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 7m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R0014 - Laboratory L.S. - 86.16 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00D - R0015 - General Storeroom - 13.18 m2
No Asbestos
B00D - R0016 - Careers Advisers Office - 26.87 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00D - R0017 - General Learning Space - 50.67 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00D - R0019 - Preparation - Science - 39 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00D - R0020 - Plant - .88 m2
No Asbestos
B00D - R0021 - Handwashing Facilities - .23 m2
No Asbestos
B00D - R0022 - Toilets-Girls - 40.86 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Partition Walls(Cubicles)
Compressed AC Sheet 15m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos) , Amosite(brown asbestos) , Crocidolite (blueasbestos)
B00D - R0023 - Plant - 1.04 m2
No Asbestos
B00D - R0024 - Toilets-Boys - 31.39 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Partition Walls(Cubicles)
Compressed AC Sheet 15m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos) , Amosite(brown asbestos) , Crocidolite (blueasbestos)
B00D - R0025 - Plant - 2.38 m2
No Asbestos
B00D - R0026 - Plant - 2.38 m2
No Asbestos
B00D - R0027 - Plant - .89 m2
No Asbestos
B00D - R0028 - Handwashing Facilities - .23 m2
No Asbestos
B00D - R0029 - External Stairs - 3.4 m2
No Asbestos
B00D - R0030 - External Stairs - 3.54 m2Miller Technology High School (8394) 9/09/2020 15/29
Note: No inspection of live electrical installation
Note: No inspection of live electrical installation
No Asbestos
B00D - R0031 - External Movement - 139.57 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00D - R0032 - Lift - 2.57 m2
No Asbestos
B00D - R0033 - Plant - .94 m2
No Asbestos
B00D - R1001 - General Learning Space - 59.24 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 60m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R1002 - Resources Store - 12.44 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 13m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R1003 - Resources Store - 5.13 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00D - R1004 - General Learning Space - 53.6 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 54m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R1005 - General Learning Space - 59.09 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00D - R1008 - Computer Learning Space - 59.09 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00D - R1009 - Distribution Board Cupboard - .9 m2
No Asbestos
B00D - R1010 - Distribution Board Cupboard - .88 m2
No Asbestos
B00D - R1011 - General Learning Space - 53.6 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 54m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R1013 - Computer Learning Space - 59.09 m2
CeilingStructures/Linings
Vermiculite
Floor CoveringsRes/Textile
Vinyl Tiles 59m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R1014 - General Learning Space - 52.8 m2
Miller Technology High School (8394) 9/09/2020 16/29
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 53m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R1015 - General Learning Space - 52.8 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 53m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R1017 - General Learning Space - 53.24 m2
Floor CoveringsRes/Textile
Vinyl Tiles 53m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R1019 - Staff Study - 34.83 m2
Floor CoveringsRes/Textile
Vinyl Tiles 34.83m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00D - R1020 - Tea Room - 2.19 m2
No Asbestos
B00D - R1021 - Interview/Office - Type 1 - 20.04 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00D - R1022 - Tea Room - 2.56 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00D - R1023 - Handwashing Facilities - .23 m2
No Asbestos
B00D - R1024 - Handwashing Facilities - .24 m2
No Asbestos
B00D - R1025 - External Stairs - 5.69 m2
No Asbestos
B00D - R1026 - External Stairs - 5.75 m2
No Asbestos
B00D - R1028 - External Movement - 151.16 m2
No Asbestos
B00E - Library/General Learning/Science Learning - 1965 - Brick/BlockExterior
Ceiling Voids No Asbestos Found
Underfloor Voids -Slab on Ground
Non Accessible Area
External WallStructure
Compressed AC Sheet 50 East & West GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos) , Amosite(brown asbestos) , Crocidolite (blueasbestos)
Interior
B00E - R0001 - Staff Study - 12.82 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0002 - Resources Store - 6.36 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0003 - Resources Store - 6.13 m2Miller Technology High School (8394) 9/09/2020 17/29
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0004 - Staff Study - 39.32 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 40m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R0006 - Design L.S. - 52.7 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0007 - Resources Store - 11.55 m2
No Asbestos
B00E - R0009 - Resources Store - 32.37 m2
CeilingStructures/Linings
Vermiculite
Floor CoveringsRes/Textile
Vinyl Sheet
B00E - R0010 - General Learning Space - 52.72 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0011 - Chemical Store - 25.96 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0012 - Laboratory L.S. - 92.65 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Furniture / Fixtures Compressed AC Sheet 2 South, Middle portion GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R0013 - Resources Store - 10.16 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 11m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R0014 - Preparation - Science - 28.47 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 29m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
Plant / Equipment -Fume Cupboard
Flat AC Sheeting 2 East, West, Middleportion, Variablepositions
GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R0015 - Laboratory L.S. - 85.75 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 86m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
Miller Technology High School (8394) 9/09/2020 18/29
Furniture / Fixtures Compressed AC Sheet 2 South, Middle portion GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R0016 - General Storeroom - 4.17 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0019 - Seminar - 13.25 m2
No Asbestos
B00E - R0020 - Seminar - 13.25 m2
No Asbestos
B00E - R0021 - Resources Store - 13.56 m2
No Asbestos
B00E - R0022 - Library Administration - 36.13 m2
No Asbestos
B00E - R0023 - Audio Visual Workroom - 26.87 m2
No Asbestos
B00E - R0024 - Computer Room - 7 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0025 - Librarian - 12.31 m2
No Asbestos
B00E - R0027 - Plant - .59 m2
CeilingStructures/Linings
Flat AC Sheeting 1m2 Throughout GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R0028 - General Learning Space - 67.69 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 67.69m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R0029 - Resources Store - 4.26 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0030 - Cleaning Store - Distributed - 5.73 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0031 - Toilet - Lobby - 1.25 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0032 - Staff - Toilet - 3.65 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0033 - Handwashing Facilities - .19 m2
Wall LiningsInternal
Flat AC Sheeting 1.5m2 East GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R0034 - Handwashing Facilities - .18 m2
Wall LiningsInternal
Flat AC Sheeting 0.18m2 West GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R0035 - External Stairs - 2.76 m2
Miller Technology High School (8394) 9/09/2020 19/29
No Asbestos
B00E - R0036 - External Stairs - 1.23 m2
No Asbestos
B00E - R0037 - External Stairs - 2.25 m2
No Asbestos
B00E - R0038 - External Movement - 178.27 m2
Wall LiningsInternal - Infill
Flat AC Sheeting
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0039 - Main Entry - 16.24 m2
No Asbestos
B00E - R0040 - Main Area - 286.93 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R0041 - General Storeroom - 5.34 m2
CeilingStructures/Linings
Vermiculite
B00E - R0042 - Plant - .65 m2
No Asbestos
B00E - R1001 - General Learning Space - 53.75 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 55m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1002 - General Learning Space - 67.44 m2
Floor CoveringsRes/Textile
Vinyl Tiles 67.56m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
CeilingStructures/Linings
Vermiculite
B00E - R1003 - Resources Store - 8.88 m2
CeilingStructures/Linings
Vermiculite
Floor CoveringsRes/Textile
Vinyl Tiles 9m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1004 - Resources Store - 8.57 m2
CeilingStructures/Linings
Vermiculite
Floor CoveringsRes/Textile
Vinyl Tiles 9m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1005 - Staff Study - 26.07 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 27m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1006 - Staff Study - 38.27 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Miller Technology High School (8394) 9/09/2020 20/29
Note: No inspection of live electrical installation
Floor CoveringsRes/Textile
Vinyl Tiles 40m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1008 - General Learning Space - 59.01 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 60m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1009 - General Learning Space - 52.72 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 54m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1010 - General Learning Space - 52.65 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 54m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1011 - Resources Store - 12.8 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 13m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1012 - General Storeroom - 6.19 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 7m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1013 - Resources Store - 6.12 m2
Floor CoveringsRes/Textile
Vinyl Tiles 7m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R1015 - General Learning Space - 59.08 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 65m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1016 - Cleaning Store - Distributed - 4.17 m2
CeilingStructures/Linings
Vermiculite
B00E - R1017 - Distribution Board Cupboard - .6 m2
No Asbestos
B00E - R1018 - General Learning Space - 53.67 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Miller Technology High School (8394) 9/09/2020 21/29
Note: No inspection of live electrical installation
Floor CoveringsRes/Textile
Vinyl Tiles 55m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1019 - Resources Store - 6.13 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R1020 - Office/Store - 15.61 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 14m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1021 - General Learning Space - 58.92 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 60m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1022 - General Learning Space - 52.51 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 55m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1023 - General Learning Space - 53.53 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 55m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1025 - Distribution Board Cupboard - .62 m2
No Asbestos
B00E - R1027 - General Learning Space - 52.58 m2
Floor CoveringsRes/Textile
Vinyl Tiles 52.58m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R1028 - External Stairs - 4.65 m2
No Asbestos
B00E - R1029 - Handwashing Facilities - .2 m2
Wall LiningsInternal
Flat AC Sheeting 0.2m2 East GoodCondition(1)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1030 - External Stairs - 4.42 m2
No Asbestos
B00E - R1031 - Toilet - Lobby - 1.31 m2
No Asbestos
B00E - R1032 - Staff - Toilet - 3.69 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
B00E - R1033 - Handwashing Facilities - .19 m2
No Asbestos
Miller Technology High School (8394) 9/09/2020 22/29
B00E - R1034 - External Stairs - 4.39 m2
No Asbestos
B00E - R1035 - Resources Store - 26.03 m2
CeilingStructures/Linings
Vermiculite - CompositeSample - ( 40 - 70 m2) - ( X5)
Floor CoveringsRes/Textile
Vinyl Tiles 26.03m2 Throughout FriableAsbestos(5)
Low(1)
Low Priority(2-3)
Chrysotile (white asbestos)
B00E - R1036 - External Movement - 209.29 m2
No Asbestos
B00F - Multi Purpose Facilities - 1997 - Brick/BlockExterior
Ceiling Voids No Asbestos Found
Underfloor Voids No Asbestos Found
Interior
B00F - R0003 - Toilets-Disabled - 7.51 m2
No Asbestos
B00F - R0004 - Plant - .65 m2
No Asbestos
B00F - R0006 - Sport Equipment Store - 26.49 m2
No Asbestos
B00F - R0007 - Performance Store - 16.18 m2
No Asbestos
B00F - R0008 - Toilets-Boys - 10.55 m2
No Asbestos
B00F - R0009 - Other-Community Use - 16.18 m2
No Asbestos
B00F - R0010 - Other-Community Use - 10.55 m2
No Asbestos
B00F - R0011 - Control Room - 3.14 m2
No Asbestos
B00F - R0012 - Chair Store - 33.17 m2
No Asbestos
B00F - R0013 - External Movement - 7.53 m2
No Asbestos
B00F - R0014 - Movement - 41.29 m2
No Asbestos
B00F - R0015 - Staff Kitchen - 20.92 m2
No Asbestos
B00F - R0016 - Staff Kitchen - 7.94 m2
No Asbestos
B00F - R0017 - Toilets-Girls - 15.24 m2
Partition Walls(Cubicles)
Flat AC Sheeting
Wall LiningsInternal
Flat AC Sheeting
B00F - R0018 - Toilets-Boys - 12.42 m2
Wall LiningsInternal
Flat AC Sheeting
Partition Walls(Cubicles)
Flat AC Sheeting
B00F - R0019 - Multi-Purpose Space - 497.71 m2
Miller Technology High School (8394) 9/09/2020 23/29
No Asbestos
B00F - R0020 - Movement - 1.48 m2
No Asbestos
B00F - R0021 - Stairs - 1.25 m2
No Asbestos
B00F - R0022 - Stage - 121.35 m2
No Asbestos
B00F - R0023 - Stairs - 1.27 m2
No Asbestos
B00F - R0024 - Movement - 2.61 m2
No Asbestos
B00F - R0025 - Ramp - 18.78 m2
No Asbestos
B00F - R0026 - Garden Store Room - 5.86 m2
No Asbestos
B00F - R0027 - Garden Store Room - 14.17 m2
No Asbestos
B00G - Physical Education - 2004 - SteelExterior
Ceiling Voids No Asbestos Found
Underfloor Voids -Slab on Ground
Non Accessible Area
Interior
B00G - M0001 - Fitness Laboratory - 22.54 m2
No Asbestos
B00G - M0002 - Stairs - 3.76 m2
No Asbestos
B00G - R0001 - Fitness Laboratory - 121.65 m2
No Asbestos
B00G - R0002 - Stairs - .66 m2
No Asbestos
B00H - Mechanical Services - 2010 - SteelExterior
Underfloor Voids -Slab on Ground
Non Accessible Area
Ceiling Voids No Asbestos Found
Interior
B00H - R0001 - Workshop - 174.76 m2
No Asbestos
B00H - R0002 - General Learning Space - 30.77 m2
No Asbestos
B00H - R0003 - Outdoor Workshop - 70.18 m2
No Asbestos
B00H - R0004 - External Movement - 35.83 m2
No Asbestos
B00I - Other - 2011 - Brick/BlockExterior
Underfloor Voids No Asbestos Found
Ceiling Voids No Asbestos Found
Interior
B00I - R0001 - Toilets-Disabled - 11.09 m2
Miller Technology High School (8394) 9/09/2020 24/29
No Asbestos
B00Y - Electrical Services - 1965 - Brick/BlockExterior
Ceiling Voids No Asbestos Found
Underfloor Voids -Slab on Ground
Non Accessible Area
Interior
B00Y - R0001 - Main Switchroom - 8.2 m2
No Asbestos
B00Y - R0002 - Stairs - 3.13 m2
No Asbestos
B00Y - R0003 - External Movement - 1 m2
No Asbestos
B00Y - R9001 - Stairs - 3.13 m2
No Asbestos
B00Y - R9002 - Other-Vacant - 11.56 m2
No Asbestos
B00Z - Building Services - 1965 - Brick/BlockExterior
Eaves Linings Flat AC Sheeting
Underfloor Voids Requires Inspection
Ceiling Voids Requires Inspection
Interior
B00Z - R0001 - Plant - 6.46 m2
Material - Stored /Debris Material
Flat AC Sheeting
Miller Technology High School (8394) 9/09/2020 25/29
Demountables
OS 600 11690 - Learning Unit - Small - Placement Date : 06-JAN-2000Exterior
Eaves Linings Flat AC Sheeting 8.64m2 Assumed Asbestos
Landing Compressed AC Sheet 1.2m2 Assumed Asbestos
Step Treads Compressed AC Sheet 1.08m2 Assumed Asbestos
Interior
R1- General Learning Space
End Wall Panel Flat AC Sheeting 50m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 55m2 Assumed Asbestos
OS 521 11770 - Staff Study - Placement Date : 09-OCT-1996Exterior
Eaves Linings Flat AC Sheeting 11.52m2 Assumed Asbestos
Landing Compressed AC Sheet 1.2m2 Assumed Asbestos
Step Treads Compressed AC Sheet 1.08m2 Assumed Asbestos
Interior
R1- Staff Room
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 55m2 Assumed Asbestos
R2- Staff Toilet
Toilet Partitions Compressed AC Sheet 6m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 4m2 Assumed Asbestos
R3- Staff Toilet
Toilet Partitions Compressed AC Sheet 6m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 4m2 Assumed Asbestos
R4- Lobby
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 10m2 Assumed Asbestos
OS 601 11774 - Learning Unit - Standard/Withdrawal - Placement Date : 30-JUN-1995Exterior
Eaves Linings Flat AC Sheeting 11.52m2 Assumed Asbestos
Landing Compressed AC Sheet 1.2m2 Assumed Asbestos
Step Treads Compressed AC Sheet 1.08m2 Assumed Asbestos
Interior
R1- Entry
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 8m2 Assumed Asbestos
R2- General Learning Space
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 55m2 Assumed Asbestos
R3- Store
Ceiling Structures/Linings Flat AC Sheeting 10m2 Assumed Asbestos
OS 601 12320 - Learning Unit - Standard/Withdrawal - Placement Date : 07-JAN-2000Exterior
Eaves Linings Flat AC Sheeting 11.52m2 Assumed Asbestos
Landing Compressed AC Sheet 1.2m2 Assumed Asbestos
Step Treads Compressed AC Sheet 1.08m2 Assumed Asbestos
Interior
R1- Entry
Miller Technology High School (8394) 9/09/2020 26/29
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 8m2 Assumed Asbestos
R2- General Learning Space
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 55m2 Assumed Asbestos
R3- Store
Ceiling Structures/Linings Flat AC Sheeting 10m2 Assumed Asbestos
OS 601 12346 - Learning Unit - Standard/Withdrawal - Placement Date : 05-JAN-1999Exterior
Eaves Linings Flat AC Sheeting 11.52m2 Assumed Asbestos
Landing Compressed AC Sheet 1.2m2 Assumed Asbestos
Step Treads Compressed AC Sheet 1.08m2 Assumed Asbestos
Interior
R1- Entry
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 8m2 Assumed Asbestos
R2- General Learning Space
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 55m2 Assumed Asbestos
R3- Store
Ceiling Structures/Linings Flat AC Sheeting 10m2 Assumed Asbestos
OS 601 12347 - Learning Unit - Standard/Withdrawal - Placement Date : 05-JAN-1999Exterior
Eaves Linings Flat AC Sheeting 11.52m2 Assumed Asbestos
Landing Compressed AC Sheet 1.2m2 Assumed Asbestos
Step Treads Compressed AC Sheet 1.08m2 Assumed Asbestos
Interior
R1- Entry
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 8m2 Assumed Asbestos
R2- General Learning Space
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 55m2 Assumed Asbestos
R3- Store
Ceiling Structures/Linings Flat AC Sheeting 10m2 Assumed Asbestos
OS 501 12715 - Admin Staff/Principal/Deputy/Dup/Clinic - Placement Date : 16-FEB-2007Exterior
Eaves Linings Flat AC Sheeting 31.68m2 Assumed Asbestos
Landing Compressed AC Sheet 1.2m2 Assumed Asbestos
Step Treads Compressed AC Sheet 1.08m2 Assumed Asbestos
Interior
R1- Entry
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 25m2 Assumed Asbestos
R10- Staff Toilet
Toilet Partitions Compressed AC Sheet 4m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 2m2 Assumed Asbestos
R11- Cleaning Supplies
Ceiling Structures/Linings Flat AC Sheeting 2m2 Assumed Asbestos
R12- Handicap toilet
Miller Technology High School (8394) 9/09/2020 27/29
Ceiling Structures/Linings Flat AC Sheeting 2m2 Assumed Asbestos
R13- Clerk
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 16m2 Assumed Asbestos
R2- Clinic-Waiting
Ceiling Structures/Linings Flat AC Sheeting 16m2 Assumed Asbestos
R3- Security Store
Ceiling Structures/Linings Flat AC Sheeting 12m2 Assumed Asbestos
R4- Duplicating Wookroom
Ceiling Structures/Linings Flat AC Sheeting 12m2 Assumed Asbestos
R5- Clerical Office
Ceiling Structures/Linings Flat AC Sheeting 16m2 Assumed Asbestos
R6- Staff Room
Ceiling Structures/Linings Flat AC Sheeting 58m2 Assumed Asbestos
R7- Deputy Principal
Ceiling Structures/Linings Flat AC Sheeting 16m2 Assumed Asbestos
R8- Principal
Ceiling Structures/Linings Flat AC Sheeting 20m2 Assumed Asbestos
R9- Staff Toilet
Toilet Partitions Compressed AC Sheet 4m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 2m2 Assumed Asbestos
OS 600 13409 - Learning Unit - Small - Placement Date : 17-JAN-2000Exterior
Eaves Linings Flat AC Sheeting 8.64m2 Assumed Asbestos
Landing Compressed AC Sheet 1.2m2 Assumed Asbestos
Step Treads Compressed AC Sheet 1.08m2 Assumed Asbestos
Interior
R1- General Learning Space
End Wall Panel Flat AC Sheeting 50m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 55m2 Assumed Asbestos
OS 601 13526 - Learning Unit - Standard/Withdrawal - Placement Date : 22-SEP-1999Exterior
Eaves Linings Flat AC Sheeting 11.52m2 Assumed Asbestos
Landing Compressed AC Sheet 1.2m2 Assumed Asbestos
Step Treads Compressed AC Sheet 1.08m2 Assumed Asbestos
Interior
R1- Entry
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 8m2 Assumed Asbestos
R2- General Learning Space
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 55m2 Assumed Asbestos
R3- Store
Ceiling Structures/Linings Flat AC Sheeting 10m2 Assumed Asbestos
OS 601 13669 - Learning Unit - Standard/Withdrawal - Placement Date : 21-SEP-1999Exterior
Eaves Linings Flat AC Sheeting 11.52m2 Assumed Asbestos
Landing Compressed AC Sheet 1.2m2 Assumed Asbestos
Step Treads Compressed AC Sheet 1.08m2 Assumed Asbestos
InteriorMiller Technology High School (8394) 9/09/2020 28/29
R1- Entry
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 8m2 Assumed Asbestos
R2- General Learning Space
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 55m2 Assumed Asbestos
R3- Store
Ceiling Structures/Linings Flat AC Sheeting 10m2 Assumed Asbestos
OS 601 13690 - Learning Unit - Standard/Withdrawal - Placement Date : 22-SEP-1999Exterior
Eaves Linings Flat AC Sheeting 11.52m2 Assumed Asbestos
Landing Compressed AC Sheet 1.2m2 Assumed Asbestos
Step Treads Compressed AC Sheet 1.08m2 Assumed Asbestos
Interior
R1- Entry
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 8m2 Assumed Asbestos
R2- General Learning Space
End Wall Panel Flat AC Sheeting 18m2 Assumed Asbestos
Ceiling Structures/Linings Flat AC Sheeting 55m2 Assumed Asbestos
R3- Store
Ceiling Structures/Linings Flat AC Sheeting 10m2 Assumed Asbestos
NS 020 13909 - Staff Study/Store - Placement Date : 04-NOV-2009
Note: This refurbished demountable may have asbestos present in remnant mastic in window frames.
No Asbestos Found
OS 600 14301 - Learning Unit - Small - Placement Date : 05-JUL-2007No Asbestos Found
OS 600 14686 - Learning Unit - Small - Placement Date : 05-JUL-2007No Asbestos Found
Miller Technology High School (8394) 9/09/2020 29/29