9 MidiHeat EHA MA45-32E ENGLISH Rating plate Overheating limit control Figure 1 On/Off Thermostat Technical data Max.pressure 2 bar (0.2 MPa) Max.flow 300 l/min Min.flow 170 l/min Ambient temperature +5°C to +40°C Product description Pahlén’s MidiHeat EHA is a compact electric heater for swimming pools. It is fitted with an analogue thermostat that controls the temperature of the pool water (max +45ºC). The heaters metal chassis contains a water reservoir made from glass fibre reinforced polypropylene, that has efficient corrosion resistant titanium immersion heaters. The immersion heaters can be supplied with ratings from 18–60kW at 230V (220-240V 3-phase) and from 18-72kW at 400V (380-415V 3-phase). Check the name plate on the back of the heater for applicable data. Safety The heater must be installed in accordance with applicable local regulations and directives and according to the stipulations of the electrical supply utility. The heater must not be covered, placed close to inflammable material or in direct sunlight. Safety devices fitted to the heater comprise a flow monitor and manually resettable overheating protection, double contactors for each immersion heater and an interlock function (connection block P2: 1, 2) via the circulation pump contactor. The immersion heaters are controlled to provide the desired water temperature via an analogue thermostat. Under no conditions may the heater be started if it is not completely filled with water. ”The device can be used by children from the age of 8 and upwards and persons (including children) with impaired physical, sensory or mental capacity or who have a lack of experience or knowledge, as long as they have been given instructions or information about how the device is used in a safe manner, and understand the risks that may occur. Children must not be allowed to play with the device. Cleaning and maintenance of the device must not be carried out by children with guidance.” according to EN 60335-1 section 7.12. General info Please follow these specifications for water quality: Free Chlorine: 0.5–1.5 mg/litre (ppm) Combined Chlorine: 0–0.5 mg/litre (ppm) Total Chlorine: 0.5–2.0 mg/litre (ppm) Chloride (salt) content: pH-value: 7,2–7,6 Alkalinity: 60–120 mg/litre (ppm) Calcium hardness: 100–300 mg/litre (ppm)

Upload: others

Post on 09-May-2022

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MidiHeat EHA ENGLISH

9

MidiHeat EHAMA45-32E

ENGLISH

Rating plate

Overheating limit control

Figure1

On/Off

Thermostat

Technical data

Max.pressure 2bar(0.2MPa)Max.flow 300l/minMin.flow 170l/minAmbienttemperature +5°Cto+40°C

Product descriptionPahlén’sMidiHeatEHAisacompactelectricheaterforswimmingpools.Itisfittedwithananaloguethermostatthatcontrolsthetemperatureofthepoolwater(max+45ºC).Theheatersmetalchassiscontainsawaterreservoirmadefromglassfibrereinforcedpolypropylene,thathasefficientcorrosionresistanttitaniumimmersionheaters.Theimmersionheaterscanbesuppliedwithratingsfrom18–60kWat230V(220-240V3-phase)andfrom18-72kWat400V(380-415V3-phase).Check the name plate on the back of the heater for applicable data.

Safety

Theheatermustbeinstalledinaccordancewithapplicablelocalregulationsanddirectivesandaccordingtothestipulationsoftheelectricalsupplyutility.Theheatermustnotbecovered,placedclosetoinflammablematerialorindirectsunlight.Safetydevicesfittedtotheheatercompriseaflowmonitorandmanuallyresettableoverheatingprotection,doublecontactorsforeachimmersionheaterandaninterlockfunction(connectionblockP2:1,2)viathecirculationpumpcontactor.Theimmersionheatersarecontrolledtoprovidethedesiredwatertemperatureviaananaloguethermostat.Under no conditions may the heater be started if it is not completely filled with water.”Thedevicecanbeusedbychildrenfromtheageof8andupwardsandpersons(includingchildren)withimpairedphysical,sensoryormentalcapacityorwhohavealackofexperienceorknowledge,aslongastheyhavebeengiveninstructionsorinformationabouthowthedeviceisusedinasafemanner,andunderstandtherisksthatmayoccur.Childrenmustnotbeallowedtoplaywiththedevice.Cleaningandmaintenanceofthedevicemustnotbecarriedoutbychildrenwithguidance.”accordingtoEN60335-1section7.12.

General infoPleasefollowthesespecificationsforwaterquality:FreeChlorine: 0.5–1.5mg/litre(ppm)CombinedChlorine: 0–0.5mg/litre(ppm)TotalChlorine: 0.5–2.0mg/litre(ppm)Chloride(salt)content: —pH-value: 7,2–7,6Alkalinity: 60–120mg/litre(ppm)Calciumhardness: 100–300mg/litre(ppm)

Page 2: MidiHeat EHA ENGLISH

10

MidiHeat EHAMA45-32E

ENGLISH

1

4

2

3

5 5

11

9

7

6

8

10

12

1310

1. Skimmer 2.Maindrain 3. Inlet 4.JetSwim 5. Light 6. Circulationpump 7. Filter 8.MidiHeat 9. Non-returnvalve10.Drain11. Bypass valve12.Shut-offvalve13. Draining valve

Figure2

Electrical installation• Theelectricalinstallationmustbeperformedbyanauthorizedelectricianandinaccordancewiththeinstructionsincluded withtheheater.• Amainswitchmustbefittedbeforealloftheheater’selectricalconnections(L1,L2L3).Thismustbeamulti-poleswitch thatfulfilsthedemandsofIEC/EN60335-1sections7.12.2,22.2,24.3.• Werecommendtheinstallationofaresidualcurrentdevice.• Connecttheheaterinaccordancewiththeconnectiondrawing,seepages13and14.• ThecontrolvoltageisconnectedtoconnectionblockL1andNfromasinglephase230VsupplyortoL1andL2froma 3-phase230VsupplywithnoN(neutral). Notethatthecontrolvoltagemustbeequippedwithseparate5–10Afusesfortheelectricalconnections(L1,L2).• Theheatermustbeinstalledinsuchawaythatitcannotbeactivatedunlesscirculationpump(sufficientflow)isoperational, i.e.thecontrolvoltagetotheheater’scontactormustbeinterlockedviathepump’scontactor.• Donotconnecttheheatertoanincorrectpowersource.Contactthelocalelectricalutilityforthecorrectpowersource. Thevoltagetotheheatermaynotvarybymorethan+5%to-10%withrespecttothemodelandnameplatespecification.• Ondelivery,theheaterisconnectedfor400V3-phase,seefigure4+electricaldrawingpage13,butcanbereconnectedfor 230V3-phase,seefigure5+electricaldrawingpage14(appliestoallvariantsexcept72kW).• Theinputcablingforthecontrolcircuitmustalwaysbefusedfor5–10A.• Theinputcablingforthecontactorsshallbefusedinaccordancewiththetablefortheoperatingvoltageinquestion, seefigure4or5.

InstallationPiperoutingshallalwaysperformedbeforetheelectricalinstallation.Positiontheheatersothatthefrontandtopcanbeopened.Installtheconnectionssothattheheatercanbeeasilymovedforinspection, cleaning and service.Anon-returnvalvemustbeinstalledAFTERtheheaterandashut-offvalveBEFOREtheheatertoallowservicingtheheaterwithoutneedingtoemptythepool.Aby-passshouldbeinstalledandadjustedsothattherecommendedflowthroughtheheatercanbeattained.Mounttheheateronthefloor/foundationwithscrews/boltsthroughthefourØ9mmholesinthebottom.

Pipe installationConnecttheheatertothepoolsystemaccordingtotheflowdiagrambelow.Theoutletmustnotbeconnectedtoanyothertypeof tap or connection than those given.TheelectricheaterhasaG2¾”connectionforgluedattachmentofØ63mmouterdiameterPVCpiping.NOTE! Do not fit a shut-off valve between the heater and swimming pool (fit a non-return valve instead).Mixingofchlorine,acidorsimilarinthepoolwatermustalwaysbeperformedAFTERtheheater,toavoidcorrosion.

Page 3: MidiHeat EHA ENGLISH

11

MidiHeat EHAMA45-32E

ENGLISH

Figure5

3~ 220–240V Output FusesF1-4 min. cable area

2x9=18kW 32A 6mm2

2x12=24kW 50A 10mm2

2x15=30kW 50A 10mm2

3x12=36kW 50A 10mm2

3x15=45kW 50A 10mm2

4x15=60kW 50A 10mm2White Pink

Blue Blue

White Pink

Heatingelementconnectedfor220-240V3-phase

3~ 380–415V Output FusesF1-4 min. cable area

2x9=18kW 20A 2,5mm2

2x12=24kW 25A 4 mm2

2x15=30kW 32A 6mm2

3x12=36kW 25A 4 mm2

3x15=45kW 32A 6mm2

4x15=60kW 32A 6mm2

4x18=72kW 32A 6mm2White Pink

Blue Blue

White Pink

Heatingelementconnectedfor380-415V3-phase

Figure4

Figure3

NOTE!

Reconnection from 400V to 230VOndelivery,theheaterismarkedwithanameplateandconnectedfor400V3-phase(seefigure4)butcanbereconnectedfor230V3-phase.Theinputcablingtothecontactorsshouldthenbefusedaccordingtothetableabove,seefigure5+electricaldrawing.NOTE!Ifreconnectionisperformed,thesuppliedalternativeratingplatemustbefitted.

Theinputcablingforthecontactors(K1A-K4A)shallbeconnectedaccordingtotheelectricaldrawinginthewayshowninfigure3below.NOTE! It is important that the screwdriver has the correct dimensions, and is pushed into the correct hole in the correct way.

Page 4: MidiHeat EHA ENGLISH

12

MidiHeat EHAMA45-32E

ENGLISH

Starting upStart1. Checktheelectricalconnectionsandpiperouting.Turnonallexternalfuses.2. Openallthevalvesexceptthedrainvalveandfillthesystemwithwater. -Ifthewaterlevelinthepoolislowerthantheheater,fillthepoolwiththeheaterturnedoff(switchinpositionO)andstart thesystempumptofillthesystemwithwater. -Ifthesystemhasaby-pass,opentheby-passvalvehalfway.Makefinaladjustmentslater.3. Startthepump.

Temperature setting4. TurntheswitchontheelectricalheaterON.5. Setthedesiredpooltemperature(°C)byturningthethermostatknob.6. Iftheflowofwateriscorrectandthepoolwatertemperatureislowerthanthesetting,immersionheaters1and2willstart withapprox20secondsdelaytoheatthewaterandthegreen“operating”lampwilllightup.Iftheelectricalheaterhasmore thantwoimmersionheaters,no.3willstartafteranadditional5secondsandno.4approx5secondsafterthat.Thisisto avoidoverloadingthepowersupply.7. Checkthatwatertemperatureinthepoolafterawhileandmakeanyfineadjustmentstothethermostat.

Water flow/Bypass adjustmentThewaterflowisadjustedusingavalve(item22,figure2)ontheby-pass.Adjusttheby-passvalvesothattheflowthroughtheelectricalheaterisbetween170–300l/min.Topreventunauthorizedadjustment,operatingproblemsordamagetotheelectricalheater,werecommendthatthehandleoftheby-passvalveisremovedoncefinaladjustmenthasbeenmade.

MaintenanceNotethattheelectricalheateronlyoperateswhenthewaterinthesystemiscirculating.Itshouldnotoperateifthecirculationpumpisturnedofforifthedesiredtemperaturehasbeenreached.Ifthewaterinthesystemisstationaryformorethanaweek,theelectricalheatershouldbedrainedofwater.Ifthereisariskoffreezing,thepowertotheelectricalheaterandcirkulationpumpmustbeturnedoffandtheelectricalheaterandremainderofthesystemdrainedofwater.Openthesystemdrainvalveandletitremainopenuntilitistimetostartupthepoolagain.Whenreverseflushingandcleaningthepoolsystem’sfilter,theelectricalheatermustbeturnedoff.Inareasofveryhardwater,theimmersionheaterscanaccumulateacoatingofcalciumafteralongtime,whichreducesthepoweroftheelectricalheaterandthelifeoftheimmersionheaters.Insuchcases,contactanauthorizedelectricianwhocanperformaregularinspectionoftheimmersionheatersandremoveanysuchcoatingwhennecessary.

Draining the heater1. Turnofftheelectricalheaterandturnoffthemainswitchbeforedraining.2. Closetheshut-offvalve(item12figure2).3. Openthedrainingvalve(item13figure2).4. Undotheelectricalheater’soutletconnection(markedwitharedarrow)alittletoletairin.Theelectricalheatercontains approx.15litresofwater.Makesurethatallwaterhasdrainedout.5. Re-tightentheelectricalheateroutletconnectionagainoncetheheaterisfullydrained.6. Closethedrainingvalve.

With reservation for printing errors. We reserve the right to alter the technical specification and product range. Colour deviations may occur due to printing techniques.

Page 5: MidiHeat EHA ENGLISH

13

MidiHeat EHAMA45-32E

ENGLISH

380–415V 3~380–415V 3N~

Thermostat

Flowswitch

LocationdrawingTank

Externalcontactor1-phase

Externalcontactor3-phases

Over-heatinglimit control

H1 Heating element

H2Heating element

H3 Heating element

H4 Heating element

**=Potentialfreefloatingcontact

*=fusesandpowercable

Effect FuseF1-4(A)

Min.cablearea

White Pink

Blue

White Pink

Blue

White Pink

Blue

White Pink

Blue

White Pink

Blue

WHite Pink

Blue

White Pink

Blue

White Pink

Blue

Page 6: MidiHeat EHA ENGLISH

14

MidiHeat EHAMA45-32E

ENGLISH

220–240V 3~

Thermostat

Flowswitch

LocationdrawingTank

Externalcontactor1-phase

Externalcontactor3-phases

Over-heatinglimit control

H1 Heating element

H2Heating element

H3 Heating element

H4 Heating element

**=Potentialfreefloatingcontact

*=fusesandpowercable

Effect FuseF1-4(A)

Min.cablearea

Blue

White

Blue

Pink

PinkWhite

Blue

White

Blue

Pink

PinkWhite

Blue

Vit

Blue

Pink

PinkWhite

Blue

White

Blue

Pink

PinkWhite

Page 7: MidiHeat EHA ENGLISH

11

MidiHeat EHD

MA45-33E

ENGLISH

Product descriptionPahlén’s Midi Heat EHD is a compact electric heater for swimming pools. It is equipped with a digital thermostat that controls thepoolwatertemperature(max+45ºC).Itsmetalchassisplateincludeswatercontainermadeofglass-fiberreinforced polypropylenewithefficientandcorrosion-proofheatingelementsoftitanium.Theelectricheaterisineffectfrom18–60kWfor230V(220–240V3-phase)andfrom18–72kWfor400V(380–415V3-phase).Check rating plate on the back of the heater for the applicable data.SeveralMidiHeatDigitalelectricheaterscanbeconnectedinparallel(2-10devices)andcontrolledbythe(Master)electricheater instead of adjusting individual temperature settings for every one of them.

Rating platet

Overheatingprotection

Fig. 1

On/Off

SafetyThe heater must be installed in accordance with local laws and regulations and with the energy company rules.Theheatermustnotbecoveredorplacednearflammablematerialsorindirectsunlight.Theheaterbuilt-insafetydevicesareaflowswitchandamanuallyresetoverheatingprotection,dualcontactorsforeachheaterandaninterlock(terminalsP2:1,2)ofthecirculationpumpcontactor.The immersion heaters are electronically controlled by a thermostat in order to provide the desired water temperature.

The heater should under no circumstances be started without being completely filled with water.

“The device can be used by children aged from 8 years and cannot be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given some supervision or information about how to use the device safely and understand the risks that may occur. Children should not play with the appliance.Cleaningandmaintenanceshallnotbeperformedbychildrenwithoutsupervision”,accordingtotheRegulationEN60335-1Section7.12.

Tekniska data

Max. load 2bar(0.2MPa)Max.flow 300 l/minMin.flow 170l/minAmbient temperature +5ºC till +40ºC

General informationFollow these instructions concerning water quality:Freechlorine: 0.5-1.5mg/liter(ppm)Combinedchlorine: 0-0.5mg/liter(ppm)Totalchlorine: 0.5-2.0mg/liter(ppm)Chloride(salt)content: —pH-value: 7.2-7.6Alkalinity: 60-120mg/liter(ppm)Calciumhardness: 100-300mg/liter(ppm)

Page 8: MidiHeat EHA ENGLISH

12

MidiHeat EHD

MA45-33E

ENGLISH

1

4

2

3

5 5

11

12

7

6

8

10 10

9

13

Art.no.

Rev.no.

Scale

Designed by: Approved by:

Revised by: Date

Drawn by: Date

Drawing number

Assembly drawing no.

Surface treatment

part of ISO 2768-1 The tolerance class in accordance with this

E

Box 728, SE-194 27 Upplands Väsby, SwedenPhone +46 8 59411050, Fax +46 8 59086880

ASA 2016-10-03

MidiHeat master/slave

M12589 0

This

doc

umen

t and

its

cont

ents

are

the

excl

usiv

e pr

oper

ty o

f Pah

léns

and

may

not

be

copi

ed,

repr

oduc

e d, t

rans

mitt

ed o

r com

mun

icat

ed to

a th

ird

party

, or u

sed

for a

ny p

urpo

se w

ithou

t writ

ten

perm

issi

on.

Art.no.

Rev.no.

Scale

Designed by: Approved by:

Revised by: Date

Drawn by: Date

Drawing number

Assembly drawing no.

Surface treatment

part of ISO 2768-1 The tolerance class in accordance with this

E

Box 728, SE-194 27 Upplands Väsby, SwedenPhone +46 8 59411050, Fax +46 8 59086880

ASA 2016-10-03

MidiHeat master/slave

M12589 0

This

doc

umen

t and

its

cont

ents

are

the

excl

usiv

e pr

oper

ty o

f Pah

léns

and

may

not

be

copi

ed,

repr

oduc

e d, t

rans

mitt

ed o

r com

mun

icat

ed to

a th

ird

party

, or u

sed

for a

ny p

urpo

se w

ithou

t writ

ten

perm

issi

on.

Electric installations• Electricinstallationsmustbeperformedbyaqualifiedelectricianaccordingtotheinstructionssuppliedwiththeheater.• Mainswitchshouldbeinstalledbeforetheheater,sameasallthefollowingelectricconnectionsL1,L2andL3(allpole

switchescomplyingwithIEC/EN60335-1par.7.12.2,22.2,24.3.)• Pahlén recommends to install circuit breakers.• Connecttheheateraccordingtothewiringdiagram,seepages6and7.• ThecontrolvoltageisconnectedtoterminalsL1andNat3-phase400VnetandtoterminalsL1andL2at3-phase230Vnet

withoutN(neutral).Notethatthecontrolvoltagemustbefittedwithaseparatefuse(F5)at5-10Amperesforelectricconnec-tions(L1,L2).

Installation Piping must be performed before wiring.Place the heater so that the front and top parts can be opened. Install connectors so that the heater can be easily moved for inspection, cleaning and servicingA check valve should be installed AFTER the heater and a shutoff valve BEFORE the heater, so that servicing of the heater can be performed without emptying the swimming pool.Abypassconnectionshouldbeinstalledandadjustedsothattherecommendedflowthroughtheheatercanbeachieved. Ifseveral(2-10)MidiHeatdevicesareconnectedinparallel,eachMidiHeatshouldhaveitsownby-passconnectionforeasyservicing.Fixtheheateronaflathorizontalfloor/foundationwithascrew/boltthroughfourØ9mmholesinthebottom.

Piping layoutPlugtheheaterintothepoolsystemaccordingtotheflowchartbelow.Theoutletmaynotbeconnectedtoanytypeofcraneorconnections otherthan those stated here.TheheaterisequippedwithconnectionsG2¾”forbindingPVCpipeswithoutsidediameterØ63mm.Note! Do not install a shutoff valve between the heater and the swimming pool (install check valve instead). Dosing of chlorine, acid or similar must always be done AFTER the heater.

1. Skimmer 2.Maindrain 3. Inlet 4. JetSwim 5. Light 6. Pump 7. Filter 8. MidiHeat 9. Checkvalve10. Drain outlet11. Valve-bypass12.Valve-suspension

Fig.2

Fig. 3.Example of severalMidi Heat devices

Drain Drain

Page 9: MidiHeat EHA ENGLISH

13

MidiHeat EHD

MA45-33E

ENGLISH

OBS!

The incoming cables to the contactors (K1A-K4A)mustbeconnectedaccordingtothe wiring diagram on the picture.NOTE!It is important that the screwdriver is of the right size, pressed into the right hole and in the right way.

Fig. 4

Theelectricheaterisfactorywiredfor400V3-phase,butcanbeswitchedto230V3-phase(appliestoallversionsexcept72kW).Seetablebelow+wiringdiagramonpages6and7.

• Ifamotorprotectionauxiliaryrelayforthepoolcirculationpumpisavailable,itmustbeconnectedtoterminalsP1andP2,seeattachedwiringdiagramforthevoltagesandnumberofphases.Whenmotorprotectionisswitchedon,thecircuitshouldbeclosed,potential-freechangeovercontact.

• Do not connect the heater to a faulty power supply. Contact your local power company for correct power supply. Voltage to theheatermustnotvarybymorethan+5%to-10%accordingtothemodelandnameplatespecification.

• Incomingcablestothecontrolcircuitmustalwaysbesecuredat5-10A.• Incoming cables to the contactors must be secured under the table for the current operating voltage, check the product

nameplateandseetherespectivewiringdiagramandtable(Fig.6or7).• At2-10devicesconnectedinparallel,theycanallbecontrolledfromanelectricheaterinsteadofindividualtemperature

adjustmentforallotherelectricheaters.Connectionsaremadebymeansofa2-wirecommunicationcable(min.0,25mm²)on terminal J4, between each circuit boards of the electrical heaters (daisy chain).

NOTE!

3~ 380–415V Effect FuseF1-4 Min. cable area* Heatingelementconnectedfor380-415V3-phase

2x9=18kW 20A 2,5mm2

2x12=24kW 25A 4 mm2

2x15=30kW 32A 6mm2

3x12=36kW 25A 4 mm2

3x15=45kW 32A 6mm2

4x15=60kW 32A 6mm2

4x18=72kW 32A 6mm2

White Pink

Blue Blue

White Pink

Fig. 5

3~ 220–240V Effect FuseF1-4 Min. cable area* Heatingelementconnectedfor220-240V3-phase

2x9=18kW 32A 6mm2

2x12=24kW 50A 10 mm2

2x15=30kW 50A 10 mm2

3x12=36kW 50A 10 mm2

3x15=45kW 50A 10 mm2

4x15=60kW 50A 10 mm2White Pink

Blue Blue

White Pink

Fig.6

Page 10: MidiHeat EHA ENGLISH

14

MidiHeat EHD

MA45-33E

ENGLISH

J4

RS

48

5

J2

NC

NOIN

J1

L1

K2

K1

L2

/N K4

K3

FU

SE

FU

SE

TRANSFORMER

J3

OV

ER

HE

AT

CIR

CU

LA

TIO

NP

UM

P

FL

OW

SW

ITC

H

TE

MP.S

EN

SO

R

{{ { {

Controlcircuit board

www.pahlen.com

Midi Heat Digital ( 3N~ 380-415V )Electric heater with electronic thermostat18-72kW

K1B

K2B

K3B

K4B

K1A

K2A

K3A

K4A

H2 (heater)

H3 (heater)

H4 (heater)

L1

L1

10m

10m

10m

10m

10m

10m

10m

10m

10m

10m

10m

10m

N

L2

/N

E10070-62017-05-09 ASA

3~ 380V- 415V

3~ 380V- 415V

3~ 380V- 415V

3~ 380V- 415V

~220-240V

P2:

P1:

1

2

L1

NM

A1

13 14

A1

A1

A1

A1

A1

A1

A1

A2

A2

A2

A2

A2

A2

A2

A2

L1

L2

L3

M

Flo

wsw

itch

+4

Tem

p.

sen

sor

po

ol

F1

F2

F3

F4

L1

L1

L1

L1

L2

L2

L2

L2

L3

L3

L3

L3

Assembly drawing(tank)

H3

H4

H2

H1

min.0,75mm²

0,75mm²

F55-10A

F1-4 (A)

20A

25A

32A

25A

32A

32A

32A

2.5mm²

4mm²

6mm²

4mm²

6mm²

6mm²

6mm²

Effect

Fuses and power cable

2x9=18kW

2x12=24kW

2x15=30kW

3x12=36kW

3x15=45kW

4x15=60kW

4x18=72kW

Fuse min.cable area

H1 (heater)

Pink

Pink

Pink

Pink

White

White

White

White

White

White

White

White

Blue

Blue

Blue

Blue

Blue

Blue

Blue

Blue

Pink

Pink

Pink

Pink

Overheatinglimit control

2 1

External contactor1-phase

Note: Just signal circuit (5VDC)

Note: Just signal circuit (5VDC)

External contactor3-phase

S1

L1

L1

L1

L1

L2

L2

L2

L2

L3

L3

L3

L3

Pump circulation

OR

BK

BK

OR

GY

BR

WH

GN

BU

BU

YL/GN

YL/GN YL/GN

10m

YL/G

N

4mm²

YL/G

N

YL/G

N

BK

BR

WH

BK

BR

WH

BK

BR

WH

BK

BR

WH

mm²*BK

BR

WH

mm²*

mm²*

mm²*BK

BR

WH

mm²*

mm²*

mm²*

YL/GN

mm²*

YL/GN

mm²*

mm²*BK

BR

WH

mm²*

mm²*

mm²*BK

BR

WH

mm²*

mm²*

GN BK

YL

YL

4mm²

4mm²

YL/GN

mm²*

BK

*

Cable coloursBU = blueBR = brownBK = blackGN = greenGY = grayOR = orangeYL = yellowWH = white

BR

2

Pressostat1

P

3

380–415V 3N~18-72kW

Flow

sw

itch

Location drawingTank

External contactor1-phase

External contactor3-phase

Over heatinglimit control

H1 (heating element)

H2(heating element)

H3 (heating element)

H4 (heating element)

Pool

tem

p.se

nsor

Circulation pump

Only the signal circuit (5VDC)

NOTE!Only the signal circuit (5VDC)

Transformer

Fuse

Fuse

Control circuit board

Fuses & power cablesEffect Fuse

F1-4* = Min.cable area

Blue

White Pink

White PinkBlue

Blue

White Pink

White Pink

Blue

Blue

White Pink

White Pink

Blue

Blue

White Pink

White Pink

Blue

Cable colours

BK =BlackBR=BrownBU=BlueGN=GreenGY=GrayOR=OrangeWH=WhiteYL =Yellow

NOTE!

Pressure guard

Page 11: MidiHeat EHA ENGLISH

15

MidiHeat EHD

MA45-33E

ENGLISH

J4

RS

48

5

J2

NC

NOIN

J1

L1

K2

K1

L2

/N K4

K3

FU

SE

FU

SE

TRANSFORMER

J3

OV

ER

HE

AT

CIR

CU

LA

TIO

NP

UM

P

FL

OW

SW

ITC

H

TE

MP.S

EN

SO

R

{{ { {

Controlcircuit board

www.pahlen.com

Midi Heat Digital ( 3~ 220-240V )Electric heater with electronic thermostat18-60kW

K1B

K2B

K3B

K4B

K1A

K2A

K3A

K4A

H2 (heater)

H3 (heater)

H4 (heater)

L1

10m

10m

10m

10m

10m

10m

10m

10m

10m

10m

10m

10m

L2/N

E10071-62017-05-09 ASA

3~ 220V- 230V

3~ 220V- 230V

3~ 220V-230V

3~ 220V-230V

P2:

P1

:

1

2

L1

NM

A1

13 14

A1

A1

A1

A1

A1

A1

A1

A2

A2

A2

A2

A2

A2

A2

A2

L1

L2

L3

M

Flo

wsw

itch

+45°

Tem

p.se

nso

rpool

F1

F2

F3

F4

L1

L1

L1

L1

L2

L2

L2

L2

L3

L3

L3

L3

Assembly drawing(tank)

H3

H4

H2

H1

min.0,75mm²

0,75mm²

H1 (heater)

PinkWhite

White

BlueBlue

Pink

Overheatinglimit control

2 1

External contactor1-phase

Note: Just signal circuit (5VDC)

Note: Just signal circuit (5VDC)

External contactor3-phase

L1

L1

L1

L1

L2

L2

L2

L2

L3

L3

L3

L3

Pump circulation

OR

BK

BK

OR

GY

BR

WH

GN

BU

YL/GN

YL/GN YL/GN

10m

YL/G

N

4mm²

YL/G

N

YL/G

N

BK

BR

WH

BK

BR

WH

BK

BR

WH

BK

BR

WH

mm²*BK

BR

WH

mm²*

mm²*

mm²*BK

BR

WH

mm²*

mm²*

mm²*

YL/GN

mm²*

YL/GN

mm²*

mm²*BK

BR

WH

mm²*

mm²*

mm²*BK

BR

WH

mm²*

mm²*

GN BK

YL

YL

4mm²

4mm²

YL/GN

mm²*

BK

L1

F55-10AS1

L2

~220-240V

PinkWhite

White

BlueBlue

Pink

PinkWhite

White

BlueBlue

Pink

PinkWhite

White

BlueBlue

Pink

F1-4 (A)

32A

50A

50A

50A

50A

50A

6mm²

10mm²

10mm²

10mm²

10mm²

10mm²

Effect

Fuses and power cable

2x9=18kW

2x12=24kW

2x15=30kW

3x12=36kW

3x15=45kW

4x15=60kW

Fuse min.cable area*

Cable coloursBU = blueBR = brownBK = blackGN = greenGY = gråOR = orangeYL = yellowWH = white

BR

3 Pressostat1

P2

220–240V 3N~18-60kW

Flow

sw

itch

Location drawingTank

External contactor1-phase

External contactor3-phase

Over heating limit control

H1 (heating element)

H2(heating element)

H3 (heating element)

H4 (heating element)

Pool

tem

p.se

nsor

Circulation pump

Only the signal circuit (5VDC)

NOTE!Only the signal circuit (5VDC)

Transformer

Fuse

Fuse

Control circuit board

Fuses & power cablesEffect Fuse

F1-4* = Min.cable area

Blue

White

Pink

Blue

Blue

White

Pink

Blue

Blue

Pink

White

Blue

Blue

WhitePink

Blue

Cable colours

BK =BlackBR=BrownBU=BlueGN=GreenGY=GrayOR=OrangeWH=WhiteYL =Yellow

NOTE!

Pressure guard

Pink

White

White

Pink

White Pink

White

Pink

Page 12: MidiHeat EHA ENGLISH

16

MidiHeat EHD

MA45-33E

ENGLISH

29.5

A B

J4

RS

485

J2

NC

NOIN

J1

L1

K2

K1

L2/N K

4

K3

FU

SE

FU

SE

TRANSFORMER

J3

OV

ER

HE

AT

CIR

CU

LA

TIO

NP

UM

P

FLO

WS

WIT

CH

TE

MP.S

EN

SO

R

{{ { {

Controlcircuit board

www.pahlen.com

Kretskort MidiHeat summalarm

vid felnormalt läge

IN NO NC IN

Temperature adjustmentMidiHeatisfactorysetat28°Cupondelivery.The electric heater remembers the last set of desired temperatures in the event of power failure.

Set/change the required temperature:1. Press the standby button (A) on the panel.2. Setthedesiredpooltemperature(°C)bypressingblueorredarrow.Red=temp.up,blue=temp.down.3. “Heating elements” diodes on the panel indicate that the cartridges are being switched. The cartridges are sequentially

activatedwithadelay.Whenthedesiredpooltemperatureisreached,theel.Cartridgesareclosedsequentially.4. Check the pool temperature for some time and adjust if necessary any temperature offset (may be due to energy losses in

the system), see “System Settings”.

Water/Bypass adjustmentWaterflowcanbeadjustedusinganexternalvalveinby-passconnection.Adjustbypassvalvesothattheflowthroughtheelectricheaterisbetween170–300l/min.Inordertopreventtheunauthorizedhandling, operational problems or damage to the electrical heater, it is recommended that the handle of the bypass valve is removed after the adjustment is made.Atlowflowinthepoolcirculation,theelectricheaterwillbreakthewarminganddisplayerrorcodeE1.Whenthecorrectflowhasbeenachieved,theelectricalheaterrestartswithatimedelayofapproximately20seconds.

StartupStart1. Check electric connections and piping. Turn on all external fuses and circuit breakers.2. OpenallvalvestoandfromMidiHeat(exceptdrainage)andfillthesystemwithwater.- Ifthepoolwaterlevelislowerthantheheater,fillthepoolwiththeheateroffandrestartthepumpsysteminordertofill the system with water.- Ifthesystemhasabypassswitch,opentheby-passvalvehalfway(makingfinaladjustmentslater).3. Start the pump.

Alarm outputTheelectricheaterhasbuilt-inalarmoutputJ2.Therelayoutputisapotential-freechangeovercontactandisactiveatfault codes and blackouts.In the master/slave control system the alarm signal is picked only from the master.Maximumload: 8Aat250VAC 5A at 30VDC

at errornormal mode

Page 13: MidiHeat EHA ENGLISH

17

MidiHeat EHD

MA45-33E

ENGLISH

J4

RS

48

5

J2

NC

NOIN

J1

L1

K2

K1

L2

/N K4

K3

FU

SE

FU

SE

TRANSFORMER

J3

OV

ER

HE

AT

CIR

CU

LA

TIO

NP

UM

P

FL

OW

SW

ITC

H

TE

MP.S

EN

SO

R

{{ { {

Controlcircuit board

www.pahlen.com

Kretskort MidiHeat Master/Slave

MasterMaster

J4

RS

48

5

J2

NC

NOIN

J1

L1

K2

K1

L2

/N K4

K3

FU

SE

FU

SE

TRANSFORMER

J3

OV

ER

HE

AT

CIR

CU

LA

TIO

NP

UM

P

FL

OW

SW

ITC

H

TE

MP.S

EN

SO

R

{{ { {

Controlcircuit board

www.pahlen.com

Slave 1

J4

RS

48

5

J2

NC

NOIN

J1

L1

K2

K1

L2

/N K4

K3

FU

SE

FU

SE

TRANSFORMER

J3

OV

ER

HE

AT

CIR

CU

LA

TIO

NP

UM

P

FL

OW

SW

ITC

H

TE

MP.S

EN

SO

R

{{ { {

Controlcircuit board

www.pahlen.com

Slave 2

Master/slave-controlSeveralMidiHeatDigitaldevicescanbeconnectedinparallel(2-10devices)andcontrolledfroma(Master)electricheaterinstead of adjusting individual temperature settings for every one of them.Theelectricheatersconnectedtoashielded,paired2-wirecable0,25-2,5mm2.Thepartofthesignalcablethatisontheout-sideoftwoelectricheatersshouldnotbelongerthan2m.Whenyouhave[Mode]onthedisplay,pressagaintheMODEbuttonforaddressingadevicemaster(theonewhodecides)andotherdevicesasslaves(followingthemaster).Notethatyoucannotconfiguremorethan1stmaster,onlyslavesorslaveswiththe same address number (leading to communication error).

Activation delay

Temp offset

Restorefactorysettings

Error Codes

SWVer1.02

EXIT

Master

5s

0.5

Yes

1.E2

Master/ Slave no.

System configurationModebutton(B)providesaccesstosystemsettingsandwillbeshownondisplayas[Mode].DOWNarrowallowsaccessandmaking changes to the general system parameters.Mode button provides access to the resp. parameter changes by means of arrow keys. Changes to the system parameters are saved with the Mode button.Return to the start menu is automatic after 5 seconds, or when selecting [Exit] in the display + Mode button.

The last 20 error codes are stored, where 1 is the most recent.

Yes/No. Yes = Restores factory defaults and removes stored error codes,

No = lets to abandon them.

Allows, if necessary, to add a compensation value for the poss. temperature loss in

the system, so that the display shows the actual temperature of the pool water.

When you interconnect 2-10 MidiHeat devices, you decide which will be the Master

and the others are Slave 1, Slave 2... etc.

Time delay is factory set at 5 seconds. Can be changed to between 5-60 seconds.

Page 14: MidiHeat EHA ENGLISH

18

MidiHeat EHD

MA45-33E

ENGLISH

A ( 1 : 1 )

Art.no.

Rev.no.

Scale

Designed by: Approved by:

Revised by: Date

Drawn by: Date

Drawing number

Assembly drawing no.

Surface treatment

part of ISO 2768-1 The tolerance class in accordance with this

E

Box 728, SE-194 27 Upplands Väsby, SwedenPhone +46 8 59411050, Fax +46 8 59086880

TS 2012-06-21

överhettningsskyddDemontering lock

M11668 0

A

This

doc

umen

t and

its

cont

ents

are

the

excl

usiv

e pr

oper

ty o

f Pah

léns

and

may

not

be

copi

ed,

repr

oduc

e d, t

rans

mitt

ed o

r com

mun

icat

ed to

a th

ird

party

, or u

sed

for a

ny p

urpo

se w

ithou

t writ

ten

perm

issi

on.

Cap

A ( 1 : 1 )

This

doc

umen

t and

its

cont

ents

are

the

excl

usiv

e pr

oper

ty o

f Pah

léns

and

may

not

be

copi

ed,

repr

oduc

e d, t

rans

mitt

ed o

r com

mun

icat

ed to

a th

ird

party

, or u

sed

for a

ny p

urpo

se w

ithou

t writ

ten

perm

issi

on.

Art.no.

Rev.no.

Scale

Designed by: Approved by:

Revised by: Date

Drawn by: Date

Drawing number

Assembly drawing no.

Surface treatment

part of ISO 2768-1 The tolerance class in accordance with this

E

Box 728, SE-194 27 Upplands Väsby, SwedenPhone +46 8 59411050, Fax +46 8 59086880

TS 2012-06-21

överhettningsskyddDemontering lock

M11668 0

A

Cap

Reset button

In case of any errorThedisplayshowsanerrorcode,seebelow.Contactyourinstallertofixtheerror.

Error codes

Code Cause ActionE1 Flowswitchindicateslowflow Check/increasewaterflowE2 Pool water temp. sensor is not con-

nected, or is shorted/brokenCheck that the temp sensor is connected. Replace the broken temp. sensor.

E6

The overheating protection has tripped Warning!Theunitisenergizeduntilthefirstcontactoralthoughoverheating protection has been triggered.Reactivate thermal protection manually by removing a smallprotective cap and pressing the reset button

Iftheoverheatingprotectioncontinuestobetripped:contactyourinstallerorotherqualifiedservicetechnician.

E10 Circulation pump is inactive Turn on the circulation pump.E12 Communication error Check settings for Master/Slave communications. Check the communica-

tion cableHC For high temperature on the circuit

boardCheck that the ambient temperature is not higher than 40°C.

HP Watertemperatureishigherthan45°C Check that other heat sources are not enabled

In Master/slave control system, an error code and a number in parenthesis will be seen. It indicates which of the connected devices have actually failed.Example:E1(2)=indicatesthatSlaveunit2hasanerror

A reservation for possible misprints. The right to change technical specifications and assortment is reserved.Color deviations may occur due to technical reasons.

MaintenanceNote that the electric heater is working only when water circulates in the system. It will not be heated if the circulation pump is switched off or if the desired pool temperature has been reached.If the electric heater does not heat the pool water for a long period it is recommended to turn off all main power switches. If the water in the system is still for more than a week, the electrical heater must be emptied of water.Attheriskoffreezing,thepowertotheelectricheaterandthepumpshouldbeturnedoffandboththeelectricheaterandthewhole system drained of water. Open the system drain valve and leave it open until it is time to start up the pool again.Whenbackwashingandcleaningthepoolsystemfilter,theelectricheatermustbeturnedoff.In areas with hard water, the electrical heater cartridges have a lime coating that reduces the electric heater power and the cartridgesservicelifeContactanauthorizedelectricianinordertoinspecttheimmersionheatersofthetankperiodicallyandremove this coating when necessary.

Emptying the electric heater1. Turn off the electric heater and turn off all main power before emptying.2. Closeshutoffvalve(pos.12,fig.2).3. Openshutoffvalve(pos.13,fig.2).4. Disconnect the electric heater outlet connection (marked with red arrow) a little to let air in.

The electric heater holds around 15 liters of water. Take care that all water comes out.5. Tighten the electric heater outlet connection when the electric heater is completely empty.6. Let drain valve stay open (water from the rest of the system may remain).

Recovery button

Protective capProtective cap