microwave measuring system, lb 356-456 micro-moist
DESCRIPTION
1. 2. 3. 4. Microwave Measuring System, LB 356-456 Micro-Moist. Moisture Content in Coal is an important parameter: Preparation-Regulate Moisture Content Handling-Dust-Ice Transport-Weight Trading-Weight Calorific Value. 5. Microwave Measuring System, LB 356-456 Micro-Moist. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/1.jpg)
1
![Page 2: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/2.jpg)
2
![Page 3: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/3.jpg)
3
![Page 4: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/4.jpg)
4
![Page 5: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/5.jpg)
Microwave Measuring System, LB 356-456 Micro-Moist
Moisture Content in Coal is an important parameter:
Preparation-Regulate Moisture Content
Handling-Dust-Ice
Transport-Weight
Trading-Weight
Calorific Value5
![Page 6: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/6.jpg)
Microwave Measuring System, LB 356-456 Micro-Moist
• Microwave Transmission Techniques are the most accurate method of determining moisture content of Coal
• Attenuation/Area Weight
• Phase Shift/Area Weight
• Phase Shift and or/Attenuation
6
![Page 7: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/7.jpg)
Microwave Measuring System, LB 356-456 Micro-Moist
Attenuation measurementcan provide accuracy up to 1wt% moisture
Temperature dependence error
Bulk Density dependence error
Particle size dependent error
Conductivity dependent error
7
![Page 8: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/8.jpg)
Microwave Measuring System, LB 456 Micro-Moist
Phase Shift Measurement:or (Combined Attenuation and Phase Shift)
Independent of Temperature of Coal
Independent of Particle Size variations
INTEGRAL Area Weight Compensation
Accuracy of 0.2 wt% moisture achievable
8
![Page 9: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/9.jpg)
Principle of Operation
Microwave Measuring System, LB 356-456 Micro-Moist
9
![Page 10: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/10.jpg)
Microwave Measuring System, LB 354-356-456 Micro-MoistThe choice of 2.7-3.4 GHz frequency range:
• Measurement of bulk, not surface. This provides a representative measurement
• The temperature coefficient of free water crosses zero at 3 GHz
• Attenuation due to ionic conductivity (salt content,…) is reduced at higher frequencies
• Frequency analysis over the frequency range provides phase measurement greater than 360 deg with plausibility control
10
![Page 11: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/11.jpg)
Microwave Measuring System, LB 356 Micro-Moist
11
![Page 12: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/12.jpg)
Microwave Measuring System, LB 356 Micro-Moist Coal Preparation Plant:
12
![Page 13: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/13.jpg)
Microwave Measuring System, LB 356 Micro-Moist
Coal Preparation Plant management reported precision of 0.4% moisture (one sigma RMS)13
![Page 14: Microwave Measuring System, LB 356-456 Micro-Moist](https://reader036.vdocuments.site/reader036/viewer/2022062410/568160ef550346895dd026a3/html5/thumbnails/14.jpg)
Microwave Measuring System, LB 456 Micro-Moist
Product Improvements:
• Reference cable can be replaced by short link if To constant
• PT-100 Temperature Compensation with direct connection
• Detector to Evaluation Unit uses FSK (Frequency Shift Keying)
14