metodología sugerida para uso de reactivos wiener lab. en: ccx … · 2014-01-06 · c1 x.x # 1...
TRANSCRIPT
Rev. Diciembre 2004
Acido Urico ( AA y AA líquida) ......................................... 1
Albúmina............................................................................ 3
Amilasa (AA y AA líquida) ................................................ 5
Bilirrubina Directa ............................................................ 7
Bilirrubina Directa (AA) ................................................... 9
Bilirrubina Total .............................................................. 12
Bilirrubina Total (AA) ..................................................... 15
Calcio (AA) ...................................................................... 18
Calcio (Arsenazo III AA) ................................................. 21
CK .................................................................................... 23
CK -MB DS ...................................................................... 25
Colesterol (AA y AA líquida) ........................................... 27
Colinesterasa ...................................................................29
Creatinina ........................................................................32
Fosfatasa Alcalina (cin. opt. y AA líquida) ..................... 34
Fosfatasa Alcalina (AA líquida rvos. separados)............ 36
Fósforo.............................................................................39
Fructosamina ...................................................................41
Gamma GT ...................................................................... 43
Glicemia (AA y AA líquida) ............................................. 45
GOT/ASAT (AA y AA líquida) ........................................ 47
GPT/ALAT ( AA y AA líquida) ........................................ 49
HDL - Colesterol (monofase AA) .................................... 51
HDL - Colesterol (FT) ..................................................... 54
Hierro .............................................................................. 56
LDH (AA y AA líquida) ................................................... 59
LDL - Colesterol (monofase AA) ..................................... 61
Magnesio .........................................................................64
Proteínas en orina o LCR ................................................ 66
ProteínasTotales .............................................................. 68
Triglicéridos (AA y AA líquida)....................................... 70
Urea (AA y AA líquida) ................................................... 72
ASO .................................................................................. 74
Metodología sugerida para uso de reactivosWiener lab. en:
CCX Spectrum
Wiener lab.
1Rev. Diciembre 2004
CCXACIDO URICO
TEST PARAMETERS Wiener lab.
ENTRY NAME URICO SAMPLE (uL) NORMAL 5.00
REPORT NAME ACIDO URICO LOW 10.0 HIGH 2.50 NEXT
RATIO REF URICO AA TEST
TEST NUMBER UNITS PRIM MG/DL SEC G/L
TEST TYPE CALIBRATED SEC. UNITS FACTOR 0.01 DELETE
MATH LIN REG END PT PRINT DIGITS 1 TEST
REACTION DIRECTION UP
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 2.50000 TO 6 .00000 SAVE
TEST BLANK TYPE REAGENT BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA ACIDO URICO
Uricostat Enzimático AAPresentación: 4 x 50 mlCód.: 1840105Presentación: 2 x 50 mlCód.: 1840106
Uricostat Enzimático AA líquidaPresentación: 2 x 100 ml R1 + 1 x 50 ml R2Cód.: 1840107Presentación: 4 x 100 ml R1 + 1 x 100 ml R2Cód.: 1840110
PREPARACION
Observar las instrucciones del manual queacompaña el equipo.
ESTABILIDAD DEL REACTIVO
Una vez preparado el Reactivo de Trabajo esestable 30 días en refrigerador (2 - 10°C).
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia del factor
es conveniente correr tres veces la calibración y
sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
M: 2,0 - 5,0 mg/dlH: 2,5 - 6,0 mg/dl
LINEALIDAD
18 mg/dl (180 mg/l)
Wiener lab.
2Rev. Diciembre 2004
TEST NAME URICO TEST TYPE CALIBRATED
COMB TEST MATH MODEL DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR 50.0 *
SAVE
% TOL OF CAL FACTOR 10 % TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.x # 1 DEFINE
C2 x.x # 1 REAGENT
C3 x.x # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST ACIDO URICO
REAGENT NAME URICO LINEARITY (C) 1.00000 TO 18.0000 CANCEL
LOT TD INITIAL Ad 0.350
ABS LIMIT (Ad) 2.00
REAGENT VOL (uL) NORM 236
LOW 236 HIGH 236 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 300 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 360 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.0005
500 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
# Valor asignado al calibrador
Wiener lab.
3Rev. Diciembre 2004
CCXALBUMINA
TEST PARAMETERS Wiener lab.
ENTRY NAME ALB SAMPLE (uL) NORMAL 3.000
REPORT NAME ALBUMINA LOW 0.000 HIGH 0.000 NEXT
RATIO REF ALB TEST
TEST NUMBER UNITS PRIM G/DL SEC G/L
TEST TYPE CALIBRATED SEC. UNITS FACTOR 10.000 DELETE
MATH LIN REG END PT PRINT DIGITS 1 TEST
REACTION DIRECTION UP
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 3,5 TO 4,8 SAVE
TEST BLANK TYPE REAGENT BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA ALBUMINA
Albúmina AAPresentación: 6 x 120 mlCód.: 1690008
PREPARACION
Listo para usar.
ESTABILIDAD DEL REACTIVO
El Reactivo Provisto es estable a temperaturaambiente hasta la fecha de vencimientoindicada en la caja.
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
3.5 - 4.8 g/dl
LINEALIDAD
6,0 g/dl
Wiener lab.
4Rev. Diciembre 2004
TEST NAME ALB TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG END PT DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR 15 * SAVE
% TOL OF CAL FACTOR 10% TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.x # 1 DEFINE
C2 x.x # 1 REAGENT
C3 x.x # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST ALBUMINA
REAGENT NAME ALB LINEARITY (C) 0.1000 TO 6.0 CANCEL
LOT TD INITIAL Ad 0.300
ABS LIMIT (Ad) 0.780
REAGENT VOL (uL) NORM 400
LOW 0.000 HIGH 400 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 60 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 120 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING NO
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
636 / 564 A 1.00 0.000 0.000 0.000
636 / 564 A 1.00 0.000 0.000 0.000
636 / 564 A 1.00 0.000 0.000 0.000
636 / 564 A 1.00 0.000 0.000 0.000
636 / 564 A 1.00 0.000 0.000 0.000
636 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
# Valor asignado al calibrador
Wiener lab.
5Rev. Diciembre 2004
CCXAMILASA
TEST PARAMETERS Wiener lab.
ENTRY NAME AMI SAMPLE (uL) NORMAL 6.00
REPORT NAME AMILASA LOW 0.000 HIGH 3.00 NEXT
RATIO REF AMI TEST
TEST NUMBER UNITS PRIM UI/L SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG RATE KIN BLNK PRINT DIGITS 0 TEST
REACTION DIRECTION UP
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 20 TO 125 SAVE
TEST BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
VALORES DE REFERENCIA
Suero, plasma: 37°C: hasta 125 U/lorina: 37°C: hasta 680 U/l
LINEALIDAD
37°C: 1500 U/l
REACTIVOS PARA AMILASA
Amilasa 405 Cinética AAPresentación: 3 x 10 mlCód.: 1021403Amilasa 405 AA líquidaPresentación: 3 x 10 mlCód.: 1021404
PREPARACION
AA: Preparar de acuerdo a las instruccionesdel manual que acompaña al equipo.AA líquida: reactivo listo para usar.
ESTABILIDAD DEL REACTIVO
Una vez preparado el Reactivo de Trabajoes estable durante:60 días en refrigerador (2 - 10°C)
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
Wiener lab.
6Rev. Diciembre 2004
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME AMI TEST TYPE CALIBRATED
COMB TEST MATH MODEL DELETE
CAL INTERVAL (HR) CALIB
TOLERANCE RANGE (ABS/MIN) -1.000.00 TO 1.000.00 SAVE
CALIB
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST AMILASA
REAGENT NAME AMI LINEARITY (C) 5 TO 1500 CANCEL
LOT ID INITIAL Ad 0.700
ABS LIMIT (Ad) 2.000
REAGENT VOL (uL) NORM 250
LOW 0.000 HIGH 250 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 60 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 180 MIX TIME (SEC) 1.00
NUMBER OF READS 3 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
404 / 660 A 1.00 (*)13 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
(*) VALOR APROXIMADO, DEPENDE DE CADA APARATO
Wiener lab.
7Rev. Diciembre 2004
CCXBILIRRUBINA DIRECTA
TEST PARAMETERS Wiener lab.
ENTRY NAME BIL D SAMPLE (uL) NORMAL 10.0
REPORT NAME BIL DIR LOW 0.000 HIGH 5.00 NEXT
RATIO REF BIL D TEST
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE AUX NON CALIB SEC. UNITS FACTOR 1.0000 DELETE
MATH USER LIN REG PRINT DIGITS 2 TEST
REACTION DIRECTION UP
REAGENTS 2 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 0.00000 TO 0.20000 SAVE
TEST BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
CAL FACTOR 37.6710 DEFINE
INTERCEPT (Ad) 0.00179 CALIB
DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARABILIRRUBINA DIRECTA
Bilirrubina WCód.: 1120001
PREPARACION
Reactivo 1: agua destilada.Reactivo 2 (Diazorreactivo):mezclar en la siguiente proporción:1 gota de Nitrito de sodio + 1,5 ml deReactivo Sulfanílico + 1,5 ml agua destilada.
ESTABILIDAD DEL REACTIVO
Una vez preparado el Diazorreactivo esestable durante 3 días a temp. ambiente y alabrigo de la luz.
CALIBRACION
Emplear Calibrador.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
0 - 0,20 mg/dl
LINEALIDAD
15 mg/dl (150 mg/l)
Wiener lab.
8Rev. Diciembre 2004
REAGENT NAME AGUA LINEARITY (C) 0.01000 TO 15.0000 CANCEL
LOT ID INITIAL Ad 0.100
ABS LIMIT (Ad) 0.800
REAGENT VOL (uL) NORM 175
LOW 0.000 HIGH 175 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 60 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 60 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 120 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST BIL DIR
REAGENT NAME DIAZO LINEARITY (C) 0.01000 TO 20.0000 CANCEL
LOT ID INITIAL Ad 0.300
ABS LIMIT (Ad) 1.00
REAGENT VOL (uL) NORM 25.0
LOW 0.000 HIGH 25.0 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 240 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 240 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
REAGENT NUMBER 2 FOR TEST BIL DIR
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
Wiener lab.
9Rev. Diciembre 2004
CCXBILIRRUBINA DIRECTA (DPD)
TEST PARAMETERS Wiener lab.
ENTRY NAME BIL D SAMPLE (uL) NORMAL 20.0
REPORT NAME BIL DIR LOW 25.000 HIGH 10.00 NEXT
RATIO REF BIL D TEST
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE AUX SEC. UNITS FACTOR 1.0000 DELETE
MATH LIN REG END PT PRINT DIGITS 2 TEST
REACTION DIRECTION UP
REAGENTS 2 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 0.00000 TO 0.20000 SAVE
TEST BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
DEFINE
CALIB
DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARABILIRRUBINA DIRECTA
Bilirrubina Directa AAPresentación: 200 mlCód.: 1120006
PREPARACION
R1: reactivo 1 provisto en el kitR2: reconstituir cada frasco de reactivo 2 con10 ml de reactivo 1
ESTABILIDAD DEL REACTIVO
Una vez preparado el R2 es estable 21 díasen refrigerador (2 - 10ºC).
CALIBRACION
Emplear Calibrador.* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
0 - 0,20 mg/dl
LINEALIDAD
10 mg/dl (100 mg/l)
Wiener lab.
10Rev. Diciembre 2004
TEST NAME BIL D TEST TYPE AUX
COMB TEST MATH MODEL LIN REG END PT DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) 720 CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR 33.00 *
SAVE
% TOL OF CAL FACTOR 10 % TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.x # 1 DEFINE
C2 x.x # 1 REAGENT
C3 x.x # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
# Valor asignado al calibrador
REAGENT NAME BIL D1 LINEARITY (C) 0.00000 TO 10.0000 CANCEL
LOT ID INITIAL Ad 0.100
ABS LIMIT (Ad) 1.100
REAGENT VOL (uL) NORM 200
LOW 200 HIGH 200 BEFORE WASH CYCLES 5
FIRST READ TIME (SEC) 0 AFTER WASH CYCLES 5
LAST READ TIME (SEC) 20 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 120 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST BIL DIR
Wiener lab.
11Rev. Diciembre 2004
REAGENT NAME BIL D2 LINEARITY (C) 0.00000 TO 10.0000 CANCEL
LOT ID INITIAL Ad 0.100
ABS LIMIT (Ad) 1.100
REAGENT VOL (uL) NORM 49.9
LOW 49.9 HIGH 49.9 BEFORE WASH CYCLES 5
FIRST READ TIME (SEC) 300 AFTER WASH CYCLES 5
LAST READ TIME (SEC) 300 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
REAGENT NUMBER 2 FOR TEST BIL DIR
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
Wiener lab.
12Rev. Diciembre 2004
CCXBILIRRUBINA TOTAL
TEST PARAMETERS Wiener lab.
ENTRY NAME BIL T SAMPLE uL NORMAL 10.0
REPORT NAME BILIRRUBINA TOTAL LOW 0.000 HIGH 5.00 NEXT
RATIO REF BIL T TEST
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE AUX SEC. UNITS FACTOR DELETE
MATH (LIN REG END PT) PRINT DIGITS 2 TEST
REACTION DIRECTION UP
REAGENTS 2 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 0.00000 TO 1.00000 SAVE
TEST BLANK TYPE (SERUM BLANK) TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA BILIRRUBINA TOTAL
Bilirrubina WCód.: 1120001
PREPARACION
Reactivo 1 (Desarrollador): listo para usar.Reactivo 2 (Diazorreactivo):mezclar en la siguiente proporción:1 gota de Nitrito de sodio + 1,5 ml deReactivo Sulfanílico + 1,5 ml agua destilada.
ESTABILIDAD DEL REACTIVO
Una vez preparado el Diazorreactivo esestable durante 3 días a temp. ambiente y alabrigo de la luz.
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
0 - 1,00 mg/dl
LINEALIDAD
15mg/dl (150 mg/l)
Wiener lab.
13Rev. Diciembre 2004
TEST NAME BIL T TEST TYPE AUX
COMB TEST MATH MODEL LIN REG END PT DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR 37.6700 *
SAVE
% TOL OF CAL FACTOR 10 % TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
BILI x.x # 1 DEFINE
BILI x.x # 1 REAGENT
BILI x.x # 1
BILI x.x # 1
0.00000 0
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST BILIRRUBINA TOTAL
REAGENT NAME DESARROLLADOR LINEARITY (C) 0.01000 TO 15.00 CANCEL
LOT TD INITIAL Ad 0.200
ABS LIMIT (Ad) 1.00
REAGENT VOL (uL) NORM 175
LOW 0.000 HIGH 175 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 60 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 60 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 120 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
# Valor asignado al calibrador
Wiener lab.
14Rev. Diciembre 2004
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 2 FOR TEST BILIRRUBINA TOTAL
REAGENT NAME DIAZO LINEARITY (C) 0.01000 TO 15.0000 CANCEL
LOT ID INITIAL Ad 0.300
ABS LIMIT (Ad) 1.00
REAGENT VOL (uL) NORM 25.0
LOW 0.000 HIGH 25.0 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 240 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 240 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
Wiener lab.
15Rev. Diciembre 2004
CCXBILIRRUBINA TOTAL (DPD)
TEST PARAMETERS Wiener lab.
ENTRY NAME BIL T SAMPLE (uL) NORMAL 20.0
REPORT NAME BIL TOT LOW 25.000 HIGH 10.00 NEXT
RATIO REF BIL T TEST
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE AUX SEC. UNITS FACTOR 1.0000 DELETE
MATH LIN REG END PT PRINT DIGITS 2 TEST
REACTION DIRECTION UP
REAGENTS 2 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 0.00000 TO 1.00000 SAVE
TEST BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
DEFINE
CALIB
DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARABILIRRUBINA TOTAL
Bilirrubina Total AAPresentación: 200 mlCód.: 1120005
PREPARACION
R1: reactivo 1 provisto en el kitR2: reconstituir cada frasco de reactivo 2 con10 ml de reactivo 1
ESTABILIDAD DEL REACTIVO
Una vez preparado el R2 es estable 21 díasen refrigerador (2 - 10ºC).
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
0 - 1,00 mg/dl
LINEALIDAD
12 mg/dl (120 mg/l)
Wiener lab.
16Rev. Diciembre 2004
TEST NAME BIL T TEST TYPE AUX
COMB TEST MATH MODEL LIN REG END PT DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) 720 CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR 33.00 *
SAVE
% TOL OF CAL FACTOR 10 % TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.x # 1 DEFINE
C2 x.x # 1 REAGENT
C3 x.x # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
# Valor asignado al calibrador
REAGENT NAME BIL T1 LINEARITY (C) 0.00000 TO 12.0000 CANCEL
LOT ID INITIAL Ad 0.100
ABS LIMIT (Ad) 1.100
REAGENT VOL (uL) NORM 200
LOW 200 HIGH 200 BEFORE WASH CYCLES 5
FIRST READ TIME (SEC) 0 AFTER WASH CYCLES 5
LAST READ TIME (SEC) 20 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 120 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST BIL TOT
Wiener lab.
17Rev. Diciembre 2004
REAGENT NAME BIL T2 LINEARITY (C) 0.00000 TO 12.0000 CANCEL
LOT ID INITIAL Ad 0.100
ABS LIMIT (Ad) 1.100
REAGENT VOL (uL) NORM 49.9
LOW 49.9 HIGH 49.9 BEFORE WASH CYCLES 5
FIRST READ TIME (SEC) 300 AFTER WASH CYCLES 5
LAST READ TIME (SEC) 300 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
REAGENT NUMBER 2 FOR TEST BIL TOT
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
Wiener lab.
18Rev. Diciembre 2004
CCXCALCIO (Cfx)
TEST PARAMETERS Wiener lab.
ENTRY NAME CA SAMPLE (uL) NORMAL 9.00
REPORT NAME CALCIO LOW 5.00 HIGH 4.50 NEXT
RATIO REF CALCIO TEST
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE AUX SEC. UNITS FACTOR DELETE
MATH LIN REG END PT PRINT DIGITS 1 TEST
REACTION DIRECTION UP
REAGENTS 2 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 8.5 TO 10.5 SAVE
TEST BLANK TYPE REAGENT BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA CALCIO
Ca Color AAPresentación: 4 x 50 mlCód.: 1152002
PREPARACION
Reactivos listos para usarR1: BufferR2: Reactivo de Color
ESTABILIDAD DEL REACTIVO
Los Reactivos Provistos son estables atemperatura ambiente hasta la fecha devencimiento indicada en la caja.
Nota: mantener el buffer muy bien tapadocuando no está en uso, la exposiciónprolongada al aire puede afectar suestabilidad
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia delfactor es conveniente correr tres veces lacalibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
8,5 - 10,5 mg/dl
LINEALIDAD
18 mg/dl
Wiener lab.
19Rev. Diciembre 2004
TEST NAME CA TEST TYPE AUX
COMB TEST MATH MODEL LIN REG END PT DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR *SAVE
% TOL OF CAL FACTOR 10 % TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.x # 1 DEFINE
C2 x.x # 1 REAGENT
C3 x.x # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST CALCIO
REAGENT NAME BUFFER LINEARITY (C) 1.00000 TO 18.0000 CANCEL
LOT TD INITIAL Ad 0.100
ABS LIMIT (Ad) 1.000
REAGENT VOL (uL) NORM 150
LOW 300 HIGH 150 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 0 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 60 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING
READ INTERVAL (SEC) 60 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 120 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
572 / 660 A 1.00 0.000 0.000 0.000
572 / 660 A 1.00 0.000 0.000 0.000
572 / 660 A 1.00 0.000 0.000 0.000
572 / 660 A 1.00 0.000 0.000 0.000
572 / 660 A 1.00 0.000 0.000 0.000
572 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
# Valor asignado al calibrador
Wiener lab.
20Rev. Diciembre 2004
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 2 FOR TEST CALCIO
REAGENT NAME CFX LINEARITY (C) 1.00000 TO 18.0000 CANCEL
LOT ID INITIAL Ad 0.100
ABS LIMIT (Ad) 1.00
REAGENT VOL (uL) NORM 150.0
LOW 0.000 HIGH 150.0 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 180 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 240 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
572 / 660 A 1.00 0.000 0.000 0.000
572 / 660 A 1.00 0.000 0.000 0.000
572 / 660 A 1.00 0.000 0.000 0.000
572 / 660 A 1.00 0.000 0.000 0.000
572 / 660 A 1.00 0.000 0.000 0.000
572 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
Wiener lab.
21Rev. Diciembre 2004
CCXCALCIO (Arsenazo III)
TEST PARAMETERS Wiener lab.
ENTRY NAME CA -AIII SAMPLE (uL) NORMAL 3.00
REPORT NAME CALCIO LOW 5.00 HIGH 1.50 NEXT
RATIO REF CA-AIII T E S T
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG END PT PRINT DIGITS 2 TEST
REACTION DIRECTION UP
R E A G E N T S 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 8.5 TO 10.5 SAVE
TEST BLANK TYPE REAGENT BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA CALCIO
Ca Color Arsenazo III AAPresentación: 4 x 50 mlCód.: 1152004
PREPARACION
Reactivo listo para usar
ESTABILIDAD DEL REACTIVO
El Reactivos Provisto es estable en refrigerador(2 - 10ºC) hasta la fecha de vencimientoindicada en la caja.
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia del factor
es conveniente correr tres veces la calibración y
sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
8,5 - 10,5 mg/dl
LINEALIDAD
14 mg/dl
Wiener lab.
22Rev. Diciembre 2004
TEST NAME CA -AIII TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG END PT DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR *SAVE
% TOL OF CAL FACTOR 10 % TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.x # 1 DEFINE
C2 x.x # 1 REAGENT
C3 x.x # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST CALCIO
REAGENT NAME CA-AIII LINEARITY (C) 1.00000 TO 14.0000 CANCEL
LOT TD INITIAL Ad 2.0000
ABS LIMIT (Ad) 3.0000
REAGENT VOL (uL) NORM300
LOW 300 HIGH 300 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 180 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 240 MIX TIME (SEC) 1.00
NUMBER OF READS 1 C O O L I N G Y E S
READ INTERVAL (SEC) 60 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE
RSM 0 SPECTRAL CORRECTION NEXT
REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
660 / MA A 1.00 0.000 0.000 0.000
660 / MA A 1.00 0.000 0.000 0.000
660 / MA A 1.00 0.000 0.000 0.000
660 / MA A 1.00 0.000 0.000 0.000
660 / MA A 1.00 0.000 0.000 0.000
660 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
# Valor asignado al calibrador
Wiener lab.
23Rev. Diciembre 2004
CCXCK
TEST PARAMETERS Wiener lab.
ENTRY NAME CK SAMPLE (uL) NORMAL 5.00
REPORT NAME CK LOW 0.000 HIGH 1.25 NEXT
RATIO REF CK TEST
TEST NUMBER UNITS PRIM UI/L SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG RATE KIN BLNK PRINT DIGITS 0 TEST
REACTION DIRECTION UP
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 24 TO 195 SAVE
TEST BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA CREATINA KINASA
CK-NAC UV AAPresentación: 3 x 20 mlCód.: 1271303Presentación: 10 x 20 mlCód.: 1271353
PREPARACION
Preparar de acuerdo a las instrucciones delmanual que acompaña al equipo
ESTABILIDAD DEL REACTIVO
Una vez preparado el Reactivo de Trabajo esestable 20 días en refrigerador (2 - 10°C)
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
37°C: 24 - 195 U/l
LINEALIDAD
37°C: 1500 U/l
Wiener lab.
24Rev. Diciembre 2004
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME CK TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG RATE KIN BLNK DELETE
CAL INTERVAL (HR) CALIB
TOLERANCE RANGE (ABS/MIN) - 1.000.00 TO 1.000.00 SAVE
CALIB
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1 DEFINE
AUTO PRINT OFF EXIT
REAGENT NAME CK LINEARITY (C) 6.00000 TO 1500 CANCEL
LOT ID INITIAL Ad 0.600
ABS LIMIT (Ad) 2.4
REAGENT VOL (uL) NORM 236
LOW 0.000 HIGH 236 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 180 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 360 MIX TIME (SEC) 1.00
NUMBER OF READS 3 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
340 / 380 A 1.00 4,89(*) 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
(*) VALOR APROXIMADO, DEPENDE DE CADA APARATO
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST CK
Wiener lab.
25Rev. Diciembre 2004
CCXCK-MB DS
TEST PARAMETERS Wiener lab.
ENTRY NAME MB DS SAMPLE (uL) NORMAL 10.00
REPORT NAME MB DS LOW 0.000 HIGH 5.00 NEXT
RATIO REF MB DS TEST
TEST NUMBER UNITS PRIM UI/L SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG RATE KIN BLNK PRINT DIGITS 0 TEST
REACTION DIRECTION UP
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 0 TO 25 SAVE
TEST BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA CREATINA KINASA
CK-MB DS UV UnitestPresentación: 28 x 2,5 mlCod.: 1271354
PREPARACION
Preparar de acuerdo a las instrucciones delmanual que acompaña al equipo
ESTABILIDAD DEL REACTIVO
Una vez preparado el Reactivo de Trabajo esestable durante:7 días en refrigerador (2 - 10°C)
CONTROL DE CALIDAD
Control incluído en el Kit
VALORES DE REFERENCIA
37°CHasta 25 U/l
LINEALIDAD
37°C: 600 U/l
Wiener lab.
26Rev. Diciembre 2004
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME MB DS TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG RATE KIN BLNK DELETE
CAL INTERVAL (HR) CALIB
TOLERANCE RANGE (ABS/MIN) - 1.000.00 TO 1.000.00 SAVE
CALIB
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1 DEFINE
AUTO PRINT OFF EXIT
REAGENT NAME MB DS LINEARITY (C) 0.00000 TO 600 CANCEL
LOT ID INITIAL Ad 0.600
ABS LIMIT (Ad) 2.4
REAGENT VOL (uL) NORM 250
LOW 0.000 HIGH 250 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 600 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 720 MIX TIME (SEC) 1.00
NUMBER OF READS 3 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
340 / 380 A 1.00 4,89(*) 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
(*) VALOR APROXIMADO, DEPENDE DE CADA APARATO
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST MBDS
Wiener lab.
27Rev. Diciembre 2004
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia
del factor es conveniente correr tres
veces la calibración y sacar el prome-
dio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
140 - 200 mg/dl
LINEALIDAD
450 mg/dl (4,5 g/l)
COLESTEROL
TEST PARAMETERS Wiener lab.
ENTRY NAME COL SAMPLE (uL) NORMAL 2.50
REPORT NAME COLESTEROL LOW 0.000 HIGH 1.25 NEXT
RATIO REF COL TEXT
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG END PT PRINT DIGITS 0 TEST
REACTION DIRECTION UP
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 140 TO 200 SAVE
TEST BLANK TYPE REAGENT BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME
DEFINE
RATE C. OF C. 0.00000 CALIB
DEFINE
AUTO PRINT OFF
RUNNING TEST DEFINITION STATUS
CCX
REACTIVOS PARA COLESTEROL
Colestat Enzimático AAPresentación: 4 x 100 mlCód.: 1220001Presentación: 1 x 100 mlCód.: 1220110
Colestat Enzimático AA líquidaPresentación: 4 x 100 mlCód.: 1220114Presentación: 2 x 500 mlCód.: 1220222
PREPARACION
AA: Observar las instrucciones del manualque acompaña al equipo.AA líquida: líquido listo para usar.
ESTABILIDAD DEL REACTIVO
AA: el reactivo de trabajoes estable 60 días refrigerado (2-10°C).AA líquida: estable en refrigerador (2-10°C)hasta fecha de vto. indicada en la caja.
Wiener lab.
28Rev. Diciembre 2004
REAGENT NAME COL LINEARITY (C) 1.00000 TO 450.000 CANCEL
LOT TD INITIAL Ad 0.300
ABS LIMIT (Ad) 0.840
REAGENT VOL (uL) NORM 236
LOW 0.0000 HIGH 236 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 300 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 360 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
D INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
REAGENT NUMBER 1 FOR TEST COLESTEROL
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME COL TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG END PT DELETE
CALIB
CAL MODE CAL ON CMD CAL INTERVAL (HR)
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR 850.0 *SAVE
% TOL OF CAL FACTOR 10 %TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.x. # 1 DEFINE
C2 x.x # 1 REAGENT
C3 x.x # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
# Valor asignado al calibrador
Wiener lab.
29Rev. Diciembre 2004
CCX
TEST PARAMETERS Wiener lab.
ENTRY NAME CHE SAMPLE (uL) NORMAL 3.00
REPORT NAME COLINESTERASA L O W 0.000 H I G H 2.00 N E X T
RATIO REF C H E T E S T
TEST NUMBER UNITS PRIM UI/L SEC
TEST TYPE AUX SEC. UNITS FACTOR DELETE
MATH LIN REG RATE KIN BLNK PRINT DIGITS 0 TEST
REACTION DIRECTION U P
R E A G E N T S 2 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL(C) 4400 TO 13400 SAVE
TEST BLANK TYPE SERUM BLANK T E S T
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME D E F I N E
CALIB
RATE C. OF. C. 0.00000 D E F I N E
AUTO PRINT OFF E X I T
RUNNING TEST DEFINITION STATUS
VALORES DE REFERENCIA
37°C: 4400 - 13400 U/l
LINEALIDAD
37°C: 15000 U/l
REACTIVOS PARA COLINESTERASA
COLINESTERASA AAPresentación: 3 x 20ml + 3 x 6mlCód.: 1241403
PREPARACION
Preparar de acuerdo a las instrucciones delmanual que acompaña al equipo.
ESTABILIDAD DEL REACTIVO
Una vez preparado los reactivos son establesestables 6 semanas en refrigerador (2 - 10°C).
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
COLINESTERASA
Wiener lab.
30Rev. Diciembre 2004
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME C H E TEST TYPE A U X
COMB TEST MATH MODEL LIN REG RATE KIN BLNK D E L E T E
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCP TOL(C) -1000.00 TO 1000.00 REF CAL FACTOR *
%TOL OF CAL FACTOR 10 %TOL OF CAL 10 SAVE
CALIB
CAL IBRATOR LEVEL (C) R E P L I C A T E S
W A T E R 0.00000 1 D E F I N E
AUTO PRINT OFF E X I T
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST COLINESTERASA
REAGENT NAME C H E 1 LINEARITY (C) 0 T O 15000.0 C A N C E L
LOT ID INITIAL A d 0.800
ABS LIMIT (Ad) 2.400
REAGENT VOL (uL) NORM 317
LOW 0.000 HIGH 317 BEFORE WASH CYCLES 6
FIRST READ TIME (SEC) 0 AFTER WASH CYCLES 6
LAST READ TIME (SEC) 60 MIX TIME (SEC) 1.00
NUMBER OF READS 1 C O O L I N G Y E S
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 S A V E
R S M 0 SPECTRAL CORRECTION N E X T
R E A G E N T
PRIM S E C USE IN C O N S T E . F . L O W H I G H
404 / 660 A 1.00 13(*) 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF(*) VALOR APROXIMADO, DEPENDE DE CADA APARATO
Wiener lab.
31Rev. Diciembre 2004
REAGENT NUMBER 2 FOR COLINESTERASA
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NAME CHE2 LINEARITY (C) 0.0000 TO 15000.00 CANCEL
LOT TD INITIAL Ad 0.800
ABS LIMIT (Ad) 2.400
REAGENT VOL (uL) NORM 80
LOW 0.0000 HIGH 80 BEFORE WASH CYCLES 5
FIRST READ TIME (SEC) 60 AFTER WASH CYCLES 5
LAST READ TIME (SEC) 120 MIX TIME (SEC) 1.00
NUMBER OF READS 2 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE
R S M 0 SPECTRAL CORRECTION N E X T
R E A G E N T
PRIM S E C USE IN C O N S T E . F . L O W H I G H
404 / 660 A 1.00 13(*) 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
(*) VALOR APROXIMADO, DEPENDE DE CADA APARATO
Wiener lab.
32Rev. Diciembre 2004
TEST PARAMETERS Wiener lab.
ENTRY NAME CREA SAMPLE (uL) NORMAL 23.0
REPORT NAME CREATININA LOW 0.000 HIGH 12.0 NEXT
RATIO REF C R E A T E S T
TEST NUMBER UNITS PRIM MG/DL S E C
TEST TYPE CALIBRATED SEC. UNITS FACTOR D E L E T E
M A T H LIN REG END PT PRINT DIGITS 2 T E S T
REACTION DIRECTION U P
R E A G E N T S 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL(C) 0.8 T O 1.4 S A V E
TEST BLANK TYPE SERUM BLANK T E S T
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0 D E F I N E
EDIT TIME CALIB
RATE C. OF. C. 0.00000 D E F I N E
AUTO PRINT OFF E X I T
RUNNING TEST DEFINITION STATUS
CCXCREATININA
REACTIVOS PARA CREATININA
Creatinina cinética AAPresentación: 240 ml(120 ml Rvo. Alcalino / 120 ml Acido Pícrico)Cód.: 1260003
PREPARACIONReactivo de Trabajo: mezclar en partesiguales Reactivo Alcalino y Acido Pícrico.
ESTABILIDAD DEL REACTIVO
Los reactivos provistos son estables atemperatura ambiente hasta la fecha devencimiento indicada en la caja.El Reactivo de Trabajo es estable 5 horas"on board".
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
H: 0,70 - 1,30 mg/dlM: 0,60 - 1,10 mg/dl
LINEALIDAD
15 mg/dl (150 mg/l)
Wiener lab.
33Rev. Diciembre 2004
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST CREATININA
REAGENT NAME CREA LINEARITY (C) 0.30000 TO 15.00 CANCEL
LOT TD INITIAL Ad 0.400
ABS LIMIT (Ad) 1.20
REAGENT VOL (uL) NORM 236
LOW 0.000 HIGH 236 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 180 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 180 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING NO
READ INTERVAL (SEC) 60 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
516 / 604 A 1.00 0.000 0.000 0.000
516 / 604 A 1.00 0.000 0.000 0.000
516 / 604 A 1.00 0.000 0.000 0.000
516 / 604 A 1.00 0.000 0.000 0.000
516 / 604 A 1.00 0.000 0.000 0.000
516 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
TEST NAME CREA TEST TYPE CALIBRATED
COMB TEST MATH MODEL DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR *
SAVE
% TOL OF CAL FACTOR 25 %TOL OF CAL 15 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.xx # 1 DEFINE
C2 x.xx # 1 REAGENT
C3 x.xx # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
# Valor asignado al calibrador
Wiener lab.
34Rev. Diciembre 2004
CCXFOSFATASAS ALCALINA
TEST PARAMETERS Wiener lab.
ENTRY NAME ALP SAMPLE (uL) NORMAL 3.00
REPORT NAME FAL LOW 0.000 HIGH 1.50 NEXT
RATIO REF ALP TEST
TEST NUMBER UNITS PRIM UI/L SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG RATE KIN BLNK PRINT DIGITS 0 TEST
REACTION DIRECTION UP
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 65 TO 300 SAVE
TEST BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARAFOSFATASA ALCALINA
Técnica con un solo reactivo
ALP 405 cinética optimizadaPresentación: 50 x 2,5 mlCód.: 1361401ALP 405 AA líquidaPresentación: 4 x 20 ml + 1x20mlCód.: 1361402
PREPARACION
Preparar de acuerdo a las instrucciones delmanual que acompaña al equipo.
ESTABILIDAD DEL REACTIVO
cin. opt.: el Reactivo de Trabajo es estable5 días en refrigerador (2-10°C).AA líquida: el Reactivo de Trabajo es estable30 días en refrigerador (2-10°C).
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
37°C: 65 - 300 U/l
LINEALIDAD
(@) a 37°C:cin. opt.: 700 U/lAA líquida: 1500 U/l
Wiener lab.
35Rev. Diciembre 2004
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME ALP TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG RATE KIN BLNK
DELETE
CAL INTERVAL (HR) CALIB
TOLERANCE RANGE (ABS/MIN) -1000.00 TO 1000.00 SAVE
CALIB
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST FAL
REAGENT NAME ALP LINEARITY (C) 20.00000 TO (@) CANCEL
LOT ID INITIAL Ad 0.800
ABS LIMIT (Ad) 1.000
REAGENT VOL (uL) NORM 300
LOW 0.000 HIGH 300 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 60 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 300 MIX TIME (SEC) 1.00
NUMBER OF READS 4 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
412 / 452 A 1.00 15(*) 0.000 0.000
412 / 452 A 1.00 0.000 0.000 0.000
412 / 452 A 1.00 0.000 0.000 0.000
412 / 452 A 1.00 0.000 0.000 0.000
412 / 452 A 1.00 0.000 0.000 0.000
412 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
(*)VALOR APROXIMADO, DEPENDE DE CADA APARATO
(@) Ver según kit utilizado
Wiener lab.
36Rev. Diciembre 2004
CCXFOSFATASAS ALCALINA
TEST PARAMETERS Wiener lab.
ENTRY NAME ALP SAMPLE (uL) NORMAL 3.00
REPORT NAME FAL LOW 0.000 HIGH 1.50 NEXT
RATIO REF A L P T E S T
TEST NUMBER UNITS PRIM UI/L SEC
TEST TYPE AUX SEC. UNITS FACTOR DELETE
MATH LIN REG RATE KIN BLNK PRINT DIGITS 0 TEST
REACTION DIRECTION U P
R E A G E N T S 2 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL(C) 65 T O 300 S A V E
TEST BLANK TYPE REAGENT BLANK T E S T
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME D E F I N E
CALIB
RATE C. OF. C. 0.00000 D E F I N E
AUTO PRINT OFF E X I T
RUNNING TEST DEFINITION STATUS
REACTIVOS PARAFOSFATASA ALCALINA
Técnica con reactivos separados
ALP 405 AA líquidaPresentación: 4 x 20 ml + 1x20mlCód.: 1361402
PREPARACION
Reactivos líquidos listos para usar.
ESTABILIDAD DEL REACTIVO
Los reactivos son estables en refrigerador(2-10°C) hasta la fecha de vencimiento indicadaen la caja.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
37°C: 65 - 300 U/l
LINEALIDAD
37°C: 1500 U/l
Wiener lab.
37Rev. Diciembre 2004
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME ALP TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG RATE KIN BLNK
DELETE
CAL INTERVAL (HR) CALIB
TOLERANCE RANGE (ABS/MIN) -1000.00 TO 1000.00 SAVE
CALIB
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST FAL
REAGENT NAME ALP1 LINEARITY (C) 20.00000 TO 1500.00 CANCEL
LOT ID INITIAL A d 0.800
ABS LIMIT (Ad) 2.000
REAGENT VOL (uL) NORM 240
LOW 0.000 HIGH 240 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 60 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 300 MIX TIME (SEC) 1.00
NUMBER OF READS 4 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE
N E X T
R S M 0 SPECTRAL CORRECTION
R E A G E N T
PRIM S E C USE IN C O N S T E . F . L O W H I G H
412 / 452 A 1.00 15(*) 0.000 0.000
412 / 452 A 1.00 0.000 0.000 0.000
412 / 452 A 1.00 0.000 0.000 0.000
412 / 452 A 1.00 0.000 0.000 0.000
412 / 452 A 1.00 0.000 0.000 0.000
412 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
(*) VALOR APROXIMADO, DEPENDE DE CADA APARATO
Wiener lab.
38Rev. Diciembre 2004
REAGENT NUMBER 2 FOR FAL
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NAME ALP2 LINEARITY (C) 2.0000 TO 1500.00 CANCEL
LOT TD INITIAL Ad 0.800
ABS LIMIT (Ad) 2.000
REAGENT VOL (uL) NORM 60
LOW 0.0000 HIGH 60 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 240 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 240 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
D INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE
RSM 0 SPECTRAL CORRECTION NEXT
REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
412 / 452 A 1.00 15(*) 0.000 0.000
412 / 452 A 1.00 0.000 0.000 0.000
412 / 452 A 1.00 0.000 0.000 0.000
412 / 452 A 1.00 0.000 0.000 0.000
412 / 452 A 1.00 0.000 0.000 0.000
412 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFf
(*) VALOR APROXIMADO, DEPENDE DE CADA APARATO
Wiener lab.
39Rev. Diciembre 2004
CCXFOSFORO
TEST PARAMETERS Wiener lab.
ENTRY NAME FOS SAMPLE (uL) NORMAL 3.00
REPORT NAME FOSFORO LOW 0.000 HIGH 1.25 NEXT
RATIO REF F O S W T E S T
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR 1.000 0.32300
D E L E T E
M A T H LIN REG END PT PRINT DIGITS 1 T E S T
REACTION DIRECTION U P
R E A G E N T S 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 2.5 TO 5.6 SAVE
TES BLANK TYPE REAGENT BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME D E F I N E
CALIB
RATE C. OF. C. 0.00000 D E F I N E
AUTO PRINT OFF E X I T
RUNNING TEST DEFINITION STATUS
REACTIVOS PARAFOSFORO INORGANICO
Fosfatemia UV AAPresentación: 100 mlCód.: 1382321
PREPARACION
Reactivo líquido listo para usar.
ESTABILIDAD DEL REACTIVO
El Reactivo Provisto es estable atemperatura ambiente hasta la fecha devencimiento indicada en la caja.
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
2,5 - 5,6 mg/dl
LINEALIDAD
10 mg/dl
Wiener lab.
40Rev. Diciembre 2004
TEST NAME FOS TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG END PT D E L E T E
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR 17.000 *
S A V E
% TOL OF CAL FACTOR 10 %TOL OF CAL 10 CALIB
CAL LEVEL 0
CAL IBRATOR LEVEL (C) R E P L I C A T E S
W A T E R 0.00000 2
C 1 x.xx # 2 D E F I N E
C 2 x.xx # 2 R E A G E N
C 3 x.xx # 2
0.00000 0
0.00000 0
AUTO PRINT OFF E X I T
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST FOSFOROREAGENT NAME FOS LINEARITY (C) 0.50000 TO 10.0000 CANCEL
LOT TD INITIAL A d 0.500
ABS LIMIT (Ad) 1.16
REAGENT VOL (uL) NORM 300
LOW 0.000 HIGH 300 BEFORE WASH CYCLES 6
FIRST READ TIME (SEC) 360 AFTER WASH CYCLES 6
LAST READ TIME (SEC) 520 MIX TIME (SEC) 1.00
NUMBER OF READS 1 C O O L I N G Y E S
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 S A V E
N E X T
R S M 0 SPECTRAL CORRECTION R E A G E N T
PRIM S E C USE IN C O N S T E . F . L O W H I G H
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / MA L E 1.00 0.000 0.000 0.000
AUTO PRINT OFF
# Valor asignado al calibrador
Wiener lab.
41Rev. Diciembre 2004
CCXFRUCTOSAMINA
TEST PARAMETERS Wiener lab.
ENTRY NAME FRU SAMPLE (uL) NORMAL 25.00
REPORT NAME FRUCTOSAMINA L O W 0.000 H I G H 15.0 N E X T
RATIO REF F R U T E S T
TEST NUMBER UNITS PRIM uMOL/L SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH CAL LIN RATE PRINT DIGITS 0 TEST
REACTION DIRECTION U P
R E A G E N T S 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL(C) 205 TO 285 SAVE
TES BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME D E F I N E
CALIB
RATE C. OF. C. 0.00000 D E F I N E
AUTO PRINT OFF E X I T
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA FRUCTOSAMINA
Fructosamina AA líquidaPresentación: 2 x 50 mlCód.: 1400050
PREPARACION
Reactivo líquido listo para usar.
ESTABILIDAD DEL REACTIVO
El Reactivo es estable en refrigerador (2 - 10°C)hasta la fecha de vencimiento indicada en la caja.
CALIBRACION
Emplear Calibrador provisto en el kit.
* Para obtener el valor de referencia del factor es
conveniente correr tres veces la calibración y sacar el
promedio.
CONTROL DE CALIDAD
Control Fructosamina 2 nivelesWiener lab.
VALORES DE REFERENCIA
205- 285 umol/l
LINEALIDAD
800 umol/l
Wiener lab.
42Rev. Diciembre 2004
TEST NAME F R U TEST TYPE CALIBRATED
COMB TEST MATH MODEL CAL LIN RATE D E L E T E
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR *
S A V E
% TOL OF CAL FACTOR 10 % TOL OF CAL 10 CALIB
CAL LEVEL 0
CAL IBRATOR LEVEL (C) R E P L I C A T E S
W A T E R 0.00000 2
C 1 x.x # 2 D E F I N E
0.00000 0 R E A G
0.00000 0
AUTO PRINT OFF E X I T
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST FRUCTOSAMINA
REAGENT NAME F R U LINEARITY (C) 00.00000 T O 800.000 C A N C E L
LOT TD INITIAL A d 1.000
ABS LIMIT (Ad) 2.000
REAGENT VOL (uL) NORM 300
LOW 300 HIGH 300 BEFORE WASH CYCLES 6
FIRST READ TIME (SEC) 600 AFTER WASH CYCLES 6
LAST READ TIME (SEC) 900 MIX TIME (SEC) 1.00
NUMBER OF READS 6 C O O L I N G Y E S
READ INTERVAL (SEC) 60 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 S A V E
RSM 0 SPECTRAL CORRECTION NEXT
REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / 660 A 1.00 0.000 0.000 0.000
548 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
# Valor asignado al calibrador
Wiener lab.
43Rev. Diciembre 2004
CCX
TEST PARAMETERS Wiener lab.
ENTRY NAME GGT SAMPLE (uL) NORMAL 12.00
REPORT NAME GAMMA GT LOW 0.000 HIGH 5.00 NEXT
RATIO REF GGT TEST
TEST NUMBER UNITS PRIM IU/L SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG RATE KIN BLNK PRINT DIGITS 0 TEST
REACTION DIRECTION UP
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 12 TO 54 SAVE
TEST BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
VALORES DE REFERENCIA
37°C: 12 - 54 U/l
LINEALIDAD
37°C: 500 U/l
REACTIVOS PARA GAMMA GLUTAMILTRANSFERASA
γγγγγ-G-Test cinética AAPresentación: 3 x 20 mlCód.: 1421402
PREPARACION
Preparar de acuerdo a las instrucciones delmanual que acompaña al equipo
ESTABILIDAD DEL REACTIVO
Una vez preparado el Reactivo de Trabajo esestable 21 días en refrigerador (2 - 10°C)
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
γ γ γ γ γ GT
Wiener lab.
44Rev. Diciembre 2004
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME GGT TEST TYPE CALIBRATED
COMB TEST MATH MODEL DELETE
CAL INTERVAL (HR) CALIB
TOLERANCE RANGE (ABS/MIN) -1.000.00 TO 1.000.00 SAVE
CALIB
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST GAMMA GT
REAGENT NAME GGT LINEARITY (C) 5 TO 500 CANCEL
LOT ID INITIAL A d 0.500
ABS LIMIT (Ad) 1.700
REAGENT VOL (uL) NORM 236
LOW 0.000 HIGH 236 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 120 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 360 MIX TIME (SEC) 1.00
NUMBER OF READS 3 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE
R S M 0 SPECTRAL CORRECTION N E X T
R E A G E N T
PRIM S E C USE IN C O N S T E . F . L O W H I G H
404 / 660 A 1.00 (*)7,9 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / 660 A 1.00 0.000 0.000 0.000
404 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
(*)VALOR APROXIMADO, DEPENDE DE CADA APARATO
Wiener lab.
45Rev. Diciembre 2004
CCXGLICEMIA
TEST PARAMETERS Wiener lab.
ENTRY NAME GLU SAMPLE (uL) NORMAL 3.00
REPORT NAME GLUCOSA LOW 5.00 HIGH 1.50 NEXT
RATIO REF GLU TEST
TEST NUMBER UNITS PRIM MG/DL SEC G/L
TEST TYPE CALIBRATED SEC. UNITS FACTOR 0.01 DELETE
MATH LIN REG END PT PRINT DIGITS 0 TEST
REACTION DIRECTION UP
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 70 TO 110 SAVE
TEST BLANK TYPE REAGENT BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA GLUCOSA
Glicemia enzimática AAPresentación: 4 x 250 mlCód.: 1400107Presentación: 1 x 250 mlCód.: 1400106
Glicemia enzimática AA líquidaPresentación: 4 x 250 mlCód.: 1400060
PREPARACION
AA: Observar las instrucciones del manualque acompaña al equipo.AA líquida: líquido listo para usar.
ESTABILIDAD DEL REACTIVO
AA: el reactivo de trabajoes estable 60 días refrigerado (2-10°C).AA líquida: estable en refrigerador (2-10°C)hasta fecha de vto. indicada en la caja.
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
70 - 110 mg/dl
LINEALIDAD
400 mg/dl (4 g/l)
Wiener lab.
46Rev. Diciembre 2004
TEST NAME GLU TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG END PT DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR 850 *
SAVE
% TOL OF CAL FACTOR 10 % TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.x # 1 DEFINE
C2 x.x # 1 REAGENT
C3 x.x # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST GLUCOSA
REAGENT NAME GLU LINEARITY (C) 20.00000 TO 400.000 CANCEL
LOT TD INITIAL Ad 0.300
ABS LIMIT (Ad) 1.50
REAGENT VOL (uL) NORM 300
LOW 300 HIGH 300 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 300 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 360 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
# Valor asignado al calibrador
Wiener lab.
47Rev. Diciembre 2004
CCXGOT/AST
TEST PARAMETERS Wiener lab.
ENTRY NAME GOT SAMPLE (uL) NORMAL 10.0
REPORT NAME GOT LOW 0.000 HIGH 2.5 NEXT
RATIO REF GOT TEST
TEST NUMBER UNITS PRIM IU/L SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG RATE KIN BLNK PRINT DIGITS 0 TEST
REACTION DIRECTION DOWN
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 0 TO 38 SAVE
TEST BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.90000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA TRANSAMINASAGLUTAMICO OXALACETICA
GOT (AST) UV AAPresentación: 10 x 20 mlCód.: 1751302
GOT (AST) UV AA líquidaPresentación: 4x40 ml + 1x40mlCód.: 1752360
PREPARACION
AA: Reconstituir cada vial de liofilizado con20ml de bufferAA líquida: mezclar 4 partes de buffer con 1parte de sustrato.
ESTABILIDAD DEL REACTIVO
Una vez preparado el Reactivo de Trabajoes estable durante:AA: 30 días en refrigerador (2 - 10°C)AA líquida: 60 días en refrigerador (2 - 10°C)
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
37°C:H: 0 - 38 U/lM: 0 - 32 U/l
LINEALIDAD
37°C: 500 U/l
Wiener lab.
48Rev. Diciembre 2004
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME GOT TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG RATE KIN BLNK DELETE
CAL INTERVAL (HR) CALIB
TOLERANCE RANGE (ABS/MIN) TO SAVE
CALIB
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1 DEFINE
AUTO PRINT OFF EXIT
REAGENT NAME GOT LINEARITY (C) 5.00000 TO 500 CANCEL
LOT ID INITIAL Ad 0.900
ABS LIMIT (Ad) 0.500
REAGENT VOL (uL) NORM 236
LOW 0.000 HIGH 236 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 60 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 480 MIX TIME (SEC) 1.00
NUMBER OF READS 4 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
340 / 380 A 1.00 4,89(*) 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
(*) VALOR APROXIMADO, DEPENDE DE CADA APARATO
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST GOT
Wiener lab.
49Rev. Diciembre 2004
CCXGPT/ALAT
TEST PARAMETERS Wiener lab.
ENTRY NAME GPT SAMPLE (uL) NORMAL 10.0
REPORT NAME GPT LOW 0.000 HIGH 2.5 NEXT
RATIO REF GPT TEST
TEST NUMBER UNITS PRIM IU/L SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG RATE KIN BLNK PRINT DIGITS 0 TEST
REACTION DIRECTION DOWN
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 0 TO 41 SAVE
TEST BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.90000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA TRANSAMINASAGLUTAMICO PIRUVICA
GPT (ALT) UV AAPresentación: 10 x 20 mlCód.: 1761302
GPT (ALT) UV AA líquidaPresentación: 10 x 20 mlCód.: 1762360
PREPARACION
AA: Reconstituir cada vial de liofilizado con20ml de bufferAA líquida: mezclar 4 partes de buffer con 1parte de sustrato.
ESTABILIDAD DEL REACTIVO
Una vez preparado el Reactivo de Trabajoes estable durante:AA: 30 días en refrigerador (2 - 10°C).AA líquida: 60 días en refrigerador (2 - 10°C).
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
37°C:H: 0 - 41 U/lM: 0 - 31 U/l
LINEALIDAD
37°C: 500 U/l
Wiener lab.
50Rev. Diciembre 2004
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME GPT TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG RATE KIN BLNK DELETE
CAL INTERVAL (HR) CALIB
TOLERANCE RANGE (ABS/MIN) -1.000.00 TO 1000.00 SAVE
CALIB
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1 DEFINE
AUTO PRINT OFF EXIT
REAGENT NAME GPT LINEARITY (C) 5.00000 TO 500 CANCEL
LOT ID INITIAL Ad 0.900
ABS LIMIT (Ad) 0.500
REAGENT VOL (uL) NORM 236
LOW 0.000 HIGH 236 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 60 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 480 MIX TIME (SEC) 1.00
NUMBER OF READS 4 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
340 / 380 A 1.00 4,89(*) 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / MA LE 1.00 0.000 0.000 0.000
(*) VALOR APROXIMADO, DEPENDE DE CADA APARATO
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST GPT
Wiener lab.
51Rev. Diciembre 2004
TEST PARAMETERS Wiener lab.
ENTRY NAME HDL SAMPLE (uL) NORMAL 3.00
REPORT NAME HDL LOW 0.000 HIGH 1.50 NEXT
RATIO REF HDL TEXT
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE AUX SEC. UNITS FACTOR 1.00000 DELETE
MATH LIN REG END PT PRINT DIGITS 0 TEST
REACTION DIRECTION U P
R E A G E N T S 2 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL(C) 40 TO 60.0 SAVE
TEST BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME
D E F I N E
RATE C. OF C. 0.00000 CALIB
D E F I N E
AUTO PRINT OFF
RUNNING TEST DEFINITION STATUS
CCXHDL COLESTEROL
REACTIVOS PARA HDL COLESTEROL
HDL Colesterol monofase AAPresentación: 60 ml R1 + 20 ml R2Cód.: 1220112 (s/calibrador)Cód.: 1220113 (c/calibrador)
PREPARACION
Reactivos listos para usar.
ESTABILIDAD DEL REACTIVO
Una vez abiertos los Reactivos son estables21 días en refrigerador (2-10°C).
CALIBRACION
Emplear Calibrador provisto en el kit.* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
40 - 60 mg/dlValores mayores a 60 mg/dl se consideranprotectivos.
LINEALIDAD
200 mg/dl (2 g/l)
Wiener lab.
52Rev. Diciembre 2004
REAGENT NUMBER 1 FOR TEST HDL
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME HDL TEST TYPE AUX
COMB TEST MATH MODEL LIN REG END PT DELETE
CALIB
CAL MODE CAL ON CMD CAL INTERVAL (HR)
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR *
SAVE
% TOL OF CAL FACTOR 10 %TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
CAL HDL XX # 1
0.00000 1 DEFINE
0.00000 0 REAGENT
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
# Valor asignado al calibrador
REAGENT NAME HDL 1 LINEARITY (C) 30.0000 TO 200.000 CANCEL
LOT TD INITIAL Ad 0.300
ABS LIMIT (Ad) 2.00
REAGENT VOL (uL) NORM 300
LOW 0.0000 HIGH 300 BEFORE WASH CYCLES 5
FIRST READ TIME (SEC) 0 AFTER WASH CYCLES 5
LAST READ TIME (SEC) 0 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
D INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 300 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
Wiener lab.
53Rev. Diciembre 2004
REAGENT NUMBER 2 FOR TEST HDL
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NAME HDL 2 LINEARITY (C) 30.0000 TO 200.000 CANCEL
LOT TD INITIAL Ad 0.300
ABS LIMIT (Ad) 2.00
REAGENT VOL (uL) NORM 99.8
LOW 0.0000 HIGH 99.8 BEFORE WASH CYCLES 5
FIRST READ TIME (SEC) 300 AFTER WASH CYCLES 5
LAST READ TIME (SEC) 300 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
D INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
Wiener lab.
54Rev. Diciembre 2004
CCXHDL (Fosfotungstico)
TEST PARAMETERS Wiener lab.
ENTRY NAME HDL SAMPLE (uL) NORMAL 10.00
REPORT NAME HDL LOW 0.00 HIGH 3.00 NEXT
RATIO REF HDL TEST
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG END PT PRINT DIGITS 0 TEST
REACTION DIRECTION U P
R E A G E N T S 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL(C) 40 T O 60 S A V E
TEST BLANK TYPE REAGENT BLANK T E S T
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME D E F I N E
CALIB
RATE C. OF. C. 0.00000 D E F I N E
AUTO PRINT OFF E X I T
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA HDL
HDL Colesterol FTPresentación: 4 x 250 mlCód.: 1400060
Colestat Enzimático AAPresentación: 4 x 100 mlCód.: 1220001Presentación: 1 x 100 mlCód.: 1220110Colestat Enzimático AA líquidaPresentación: 4 x 100 mlCód.: 1220114Presentación: 2 x 500 mlCód.: 1220222
PREPARACION
Observar las instrucciones del manual queacompaña al equipo.
ESTABILIDAD DEL REACTIVO
El reactivo es estable en refrigerador(2-10°C) hasta la fecha de vencimientoindicada en la caja.
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
40 - 60 mg/dl
LINEALIDAD
300 mg/dl (3 g/l)
Wiener lab.
55Rev. Diciembre 2004
REAGENT NAME HDL LINEARITY (C) 0.00000 TO 300.000 CANCEL
LOT TD INITIAL A d 0.300
ABS LIMIT (Ad) 0.840
REAGENT VOL (uL) NORM 300
LOW 0.0000 HIGH 300 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 300 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 360 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/
R S M 0 SPECTRAL CORRECTION N E X T
PRIM S E C USE IN C O N S T E . F . L O W H I G H R E A G E N T
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / MA L E 1.00 0.000 0.000 0.000
AUTO PRINT OFF
REAGENT NUMBER 1 FOR TEST HDL
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME HDL TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG END PT D E L E T E
CALIB
CAL MODE CAL ON CMD CAL INTERVAL (HR)
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR *S A V E
% TOL OF CAL FACTOR 10 %TOL OF CAL 10 CALIB
CAL LEVEL 0
CAL IBRATOR LEVEL (C) R E P L I C A T E S
WATER 0.00000 1
C1 x.x # DEF
C2 x.x # 1 REAG
C3 x.x # 1
AUTO PRINT OFF E X I T
# Valor asignado al calibrador
Wiener lab.
56Rev. Diciembre 2004
CCX
TEST PARAMETERS Wiener lab.
ENTRY NAME FER SAMPLE (uL) NORMAL 25.00
REPORT NAME HIERRO LOW 0.000 HIGH 25.00 NEXT
RATIO REF FER TEST
TEST NUMBER UNITS PRIM ug/dl SEC
TEST TYPE AUX SEC. UNITS FACTOR DELETE
MATH LIN REG END POINT PRINT DIGITS 1 TEST
REACTION DIRECTION UP
R E A G E N T S 2 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 60.0000 TO 160.0000 SAVE
TEST BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
30 - 160 ug/dl
LINEALIDAD
1000 ug/dl
REACTIVOS PARA HIERRO
Fer - Color AAPresentación: 5 x 20 mlCód.: 1492003
PREPARACION
Observar las instrucciones del manual queacompaña al equipo.R1:Buffer/ReductorR2: Reactivo de color
ESTABILIDAD DEL REACTIVO
El Reactivo Provisto es estable a temperaturaambiente hasta la fecha de vencimientoindicada en la caja.Buffer/Reductor: una vez preparado esestable 3 meses refrigerado (2-10ºC)
CALIBRACION
Emplear Calibrador.
HIERRO
Wiener lab.
57Rev. Diciembre 2004
TEST NAME FER TEST TYPE AUX
COMB TEST MATH MODEL DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR *SAVE
% TOL OF CAL FACTOR 10 % TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.x # 1 DEFINE
C2 x.x # 1 REAGENT
C3 x.x # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST HIERRO
REAGENT NAME BUFFER LINEARITY (C) 20.00000 TO 700.000 CANCEL
LOT TD INITIAL Ad 0.010
ABS LIMIT (Ad) 0.500
REAGENT VOL (uL) NORM 200
LOW 0 HIGH 200 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 0 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 60 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 40 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
572 / MA A 1.00 0.000 0.000 0.000
572 / MA A 1.00 0.000 0.000 0.000
572 / MA A 1.00 0.000 0.000 0.000
572 / MA A 1.00 0.000 0.000 0.000
572 / MA A 1.00 0.000 0.000 0.000
572 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
# Valor asignado al calibrador
Wiener lab.
58Rev. Diciembre 2004
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 2 FOR TEST HIERRO
REAGENT NAME RVO.COLOR LINEARITY (C) 20.00000 TO 700.000 CANCEL
LOT TD INITIAL Ad 0.100
ABS LIMIT (Ad) 0.500
REAGENT VOL (uL) NORM 40.0
LOW 0 HIGH 40.0 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 300 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 300 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
572 / MA A 1.00 0.000 0.000 0.000
572 / MA A 1.00 0.000 0.000 0.000
572 / MA A 1.00 0.000 0.000 0.000
572 / MA A 1.00 0.000 0.000 0.000
572 / MA A 1.00 0.000 0.000 0.000
572 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
Wiener lab.
59Rev. Diciembre 2004
CCXLDH
TEST PARAMETERS Wiener lab.
ENTRY NAME LDH SAMPLE (uL) NORMAL 5.0
REPORT NAME LDH LOW 5.00 HIGH 2.50 NEXT
RATIO REF LDH TEST
TEST NUMBER UNITS PRIM IU/L SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG RATE KIN BLNK PRINT DIGITS 0 TEST
REACTION DIRECTION DOWN
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 230.000 TO 460.000 SAVE
TEST BLANK TYPE SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA LACTATO DEHIDROGENASA
LDH-P UV AAPresentación: 3 x 20 mlCód.: 1521303
LDH-P UV AA líquidaPresentación: 4 x 20 ml buffer + 1 x 20 ml sustratoCód.: 1521304
PREPARACION
Preparar de acuerdo a las instruccionesdel manual que acompaña al equipo.
ESTABILIDAD DEL REACTIVO
Una vez preparado el Reactivo de Trabajoes estable durante:AA: 21 días en refrigerador (2-10°C).AA líquida: 30 días en refrigerador (2-10°C).
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
37°C: 230-460 U/l
LINEALIDAD
37°C: 1000 U/l
Wiener lab.
60Rev. Diciembre 2004
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME LDH TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG RATE KIN BLNK DELETE
CAL INTERVAL (HR) CALIB
TOLERANCE RANGE (ABS/MIN) -1000 TO 1000 SAVE
CALIB
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1 DEFINE
AUTO PRINT OFF EXIT
REAGENT NAME LDH LINEARITY (C) 20.000 TO 1000 CANCEL
LOT ID INITIAL Ad 0.800
ABS LIMIT (Ad) 0.100
REAGENT VOL (uL) NORM 300
LOW 0.000 HIGH 300 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 60 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 300 MIX TIME (SEC) 1.00
NUMBER OF READS 3 COOLING YES
READ INTERVAL (SEC) 60 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
340 / 380 A 1.00 4,89(*) 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
(*) VALOR APROXIMADO, DEPENDE DEL APARATO
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST LDH
Wiener lab.
61Rev. Diciembre 2004
TEST PARAMETERS Wiener lab.
ENTRY NAME LDL SAMPLE (uL) NORMAL 3.00
REPORT NAME LDL LOW 0.000 HIGH 1.50 NEXT
RATIO REF LDL TEXT
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE AUX SEC. UNITS FACTOR DELETE
MATH LIN REG END PT PRINT DIGITS 0 TEST
REACTION DIRECTION U P
R E A G E N T S 2 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL(C) 0 TO 129 SAVE
TEST BLANK TYPE SERUM BLANK T E S T
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME
D E F I N E
RATE C. OF C. 0.00000 CALIB
D E F I N E
AUTO PRINT OFF
RUNNING TEST DEFINITION STATUS
CCXLDL COLESTEROL
REACTIVOS PARA LDL COLESTEROL
LDL Colesterol monofase AAPresentación: 60 ml R1 + 20 ml R2Cód.: 1220220 (c/calibrador)
PREPARACION
Reactivos listos para usar.
ESTABILIDAD DEL REACTIVO
Una vez abiertos los Reactivos son estables28 días en refrigerador (2-10°C).
CALIBRACION
Emplear Calibrador provisto en el kit.
* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
hasta 129 mg/dl
LINEALIDAD
800 mg/dl (8 g/l)
Wiener lab.
62Rev. Diciembre 2004
REAGENT NUMBER 1 FOR TEST LDL
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME LDL TEST TYPE AUX
COMB TEST MATH MODEL LIN REG END PT D E L E T E
CALIB
CAL MODE CAL ON CMD CAL INTERVAL (HR)
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR *
S A V E
% TOL OF CAL FACTOR 10 %TOL OF CAL 10 CALIB
CAL LEVEL 0
CAL IBRATOR LEVEL (C) R E P L I C A T E S
W A T E R 0.00000 1
CAL LDL XX # 1
0.00000 1 D E F I N E
0.00000 0
R E A G E N T
0.00000 0
0.00000 0
AUTO PRINT OFF E X I T
# Valor asignado al calibrador
REAGENT NAME LDL 1 LINEARITY (C) 0.0000 T O 800.000 C A N C E L
LOT TD INITIAL A d 0.300
ABS LIMIT (Ad) 2.00
REAGENT VOL (uL) NORM 300
LOW 0.0000 HIGH 300 BEFORE WASH CYCLES 5
FIRST READ TIME (SEC) 0 AFTER WASH CYCLES 5
LAST READ TIME (SEC) 0 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 300 CORRECTION LIMIT 0.00000 SAVE/
R S M 0 SPECTRAL CORRECTION N E X T
PRIM S E C USE IN C O N S T E . F . L O W H I G H R E A G E N T
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / MA L E 1.00 0.000 0.000 0.000
AUTO PRINT OFF
Wiener lab.
63Rev. Diciembre 2004
REAGENT NUMBER 2 FOR TEST LDL
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NAME LDL 2 LINEARITY (C) 0.0000 T O 800.00 C A N C E L
LOT TD INITIAL A d 0.300
ABS LIMIT (Ad) 2.00
REAGENT VOL (uL) NORM 99.8
LOW 0.0000 HIGH 99.8 BEFORE WASH CYCLES 5
FIRST READ TIME (SEC) 300 AFTER WASH CYCLES 5
LAST READ TIME (SEC) 300 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/
R S M 0 SPECTRAL CORRECTION N E X T
PRIM S E C USE IN C O N S T E . F . L O W H I G H R E A G E N T
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / 660 A 1.00 0.000 0.000 0.000
604 / MA L E 1.00 0.000 0.000 0.000
AUTO PRINT OFF
Wiener lab.
64Rev. Diciembre 2004
CCXMAGNESIO
TEST PARAMETERS Wiener lab.
ENTRY NAME MG SAMPLE (uL) NORMAL 3.00
REPORT NAME MG LOW 5.00 HIGH 2.00 NEXT
RATIO REF MG TEST
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG END PT PRINT DIGITS 1 TEST
REACTION DIRECTION UP
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 1.90000 TO 2.50000 SAVE
TEST BLANK TYPE REAGENT BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA MAGNESIO
Mg-Color AAPresentación: 2 x 50 mlCód.: 1580001
PREPARACION
Observar las instrucciones del manualque acompaña al equipo.
ESTABILIDAD DEL REACTIVO
El Reactivo es estable a Temperatura am-biente hasta la fecha de vencimiento indicadaen la caja.NOTA: mantener el Reactivo muy bientapado cuando no está en uso, la exposiciónprolongada al aire puede afectar su estabili-dad
CALIBRACION
Emplear Calibrador
* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
1.9 - 2.5 mg/dl.
LINEALIDAD
6 mg/dl
Wiener lab.
65Rev. Diciembre 2004
TEST NAME MG TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG END PT DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR *SAVE
% TOL OF CAL FACTOR 10 % TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.x # 1 DEFINE
C2 x.x # 1 REAGENT
C3 x.x # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST MG
REAGENT NAME MG LINEARITY (C) 1.00000 TO 6.0000 CANCEL
LOT TD INITIAL Ad 0.100
ABS LIMIT (Ad) 1.300
REAGENT VOL (uL) NORM 300
LOW 300 HIGH 300 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 180 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 180 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
516 / 660 A 1.00 0.000 0.000 0.000
516 / 660 A 1.00 0.000 0.000 0.000
516 / 660 A 1.00 0.000 0.000 0.000
516 / 660 A 1.00 0.000 0.000 0.000
516 / 660 A 1.00 0.000 0.000 0.000
516 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
# Valor asignado al calibrador
Wiener lab.
66Rev. Diciembre 2004
TEST PARAMETERS Wiener lab.
ENTRY NAME PROT/U SAMPLE (uL) NORMAL 5
REPORT NAME PROT/U LOW 0.000 HIGH 2.5 NEXT
RATIO REF TEST
TEST NUMBER UNITS PRIM MG/DL SEC G/L
TEST TYPE CALIBRATED SEC. UNITS FACTOR 0.01 DELETE
MATH LIN REG END PT PRINT DIGITS 0 TEST
REACTION DIRECTION UP
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) TO SAVE
TEST BLANK TYPE REAGENT BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
CCX
* Para obtener el valor de referencia delfactor es conveniente correr tres veces lacalibración y sacar el promedio.
VALORES DE REFERENCIA
Orina ocasional: 0 - 25 mg/dlOrina 24 hs.: 30 - 140 mg/24 hs.LCR: 15 - 45 mg/dl
CONTROL DE CALIDAD
ProtiU/LCR Control 2 nivelesWiener lab.
LINEALIDAD
200 mg/dl (2g/l)
REACTIVOS PARAPROTEINAS EN ORINA o LCR
PROTI U/LCRPresentación: 1 x 100 mlCód.: 1690007
PREPARACION
Listo para usar.
ESTABILIDAD DEL REACTIVO
El Reactivo Provisto es estable enrefrigerador (2-10°C) y al abrigo de la luzhasta la fecha de vencimiento indicada en lacaja.
CALIBRACION
Emplear el Standard provisto en el kit(100 mg/dl).
PROTEINAS EN ORINA O LCR
Wiener lab.
67Rev. Diciembre 2004
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST PROT/U
REAGENT NAME PROT/U LINEARITY (C) 0.0000 TO 200 CANCEL
LOT TD INITIAL Ad 0.030
ABS LIMIT (Ad) 0.250
REAGENT VOL (uL) NORM 300
LOW 0.000 HIGH 300 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 300 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 420 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/
R S M 0 SPECTRAL CORRECTION N E X T
R E A G E N T
PRIM S E C USE IN C O N S T E . F . L O W H I G H
604 / MA A 1.00 0.000 0.000 0.000
604 / MA A 1.00 0.000 0.000 0.000
604 / MA A 1.00 0.000 0.000 0.000
604 / MA A 1.00 0.000 0.000 0.000
604 / MA A 1.00 0.000 0.000 0.000
604 / MA L E 1.00 0.000 0.000 0.000
AUTO PRINT OFF
TEST NAME PROT/U TEST TYPE CALIBRATED
COMB TEST MATH MODEL DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR *
SAVE
% TOL OF CAL FACTOR 25 %TOL OF CAL 15 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.xx # 1 DEFINE
C2 x.xx # 1 REAGENT
C3 x.xx # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
# Valor asignado al calibrador
Wiener lab.
68Rev. Diciembre 2004
CCXPROTEINAS TOTALES
TEST PARAMETERS Wiener lab.
ENTRY NAME T PRO SAMPLE (uL) NORMAL 5.00
REPORT NAME PROT TOT LOW 0.000 HIGH 0.000 NEXT
RATIO REF T PRO TEST
TEST NUMBER UNITS PRIM G/DL SEC G/L
TEST TYPE CALIBRATED SEC. UNITS FACTOR 10.00 DELETE
MATH LIN REG END PT PRINT DIGITS 1 TEST
REACTION DIRECTION UP
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 6.1 TO 7.9 SAVE
TEST BLANK TYPE REAGENT BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA PROTEINASTOTALES
Proteínas Totales AAPresentación: 6 x 120 mlCód.: 1690009
PREPARACION
Listo para usar.
ESTABILIDAD DEL REACTIVO
El Reactivo Provisto es estable atemperatura ambiente hasta la fechade vencimiento indicada en la caja.
NOTA: mantener el Reactivo muy bientapado cuando no está en uso, la exposiciónprolongada al aire puede afectar suestabilidad
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia delfactor es conveniente correr tres veces lacalibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
6,1 - 7,9 g/dl
LINEALIDAD
10 g/dl
Wiener lab.
69Rev. Diciembre 2004
TEST NAME T PRO TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG END PT DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR 25*
SAVE
% TOL OF CAL FACTOR 10 % TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.x # 1 DEFINE
C2 x.x # 1 REAGENT
C3 x.x # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
REUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST T PROT TOT
REAGENT NAME T PRO LINEARITY (C) 0.40000 TO 10.00000 CANCEL
LOT TD INITIAL Ad 0.400
ABS LIMIT (Ad) 0.800
REAGENT VOL (uL) NORM 300
LOW 0.000 HIGH 0.00 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 240 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 300 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING NO
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
564 / 660 A 1.00 0.000 0.000 0.000
564 / 660 A 1.00 0.000 0.000 0.000
564 / 660 A 1.00 0.000 0.000 0.000
564 / 660 A 1.00 0.000 0.000 0.000
564 / 660 A 1.00 0.000 0.000 0.000
564 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
# Valor asignado al calibrador
Wiener lab.
70Rev. Diciembre 2004
CCXTRIGLICERIDOS
TEST PARAMETERS Wiener lab.
ENTRY NAME TRIG SAMPLE (uL) NORMAL 2.50
REPORT NAME TRIGLICERIDOS LOW 0.000 HIGH 1.25 NEXT
RATIO REF TRIG TEST
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG END PT PRINT DIGITS 0 TEST
REACTION DIRECTION UP
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 0 TO 150 SAVE
TEST BLANK TYPE REAGENT BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
REACTIVOS PARA TRIGLICERIDOS
TG Color GPO/PAP AAPresentación: 4 x 50 mlCódigo: 1780105Presentación: 10 x 20 mlCódigo: 1780101Presentación: 5 x 20 mlCódigo: 1780107TG Color GPO/PAP AA líquidaPresentación: 1 x 100 mlCódigo: 1780111TG Color GPO/PAP AA líquidaPresentación: 4 x 100 mlCódigo: 1780112
PREPARACION
AA: Observar las instrucciones del manualque acompaña al equipo.AA líquida: líquido listo para usar
ESTABILIDAD DEL REACTIVO
AA: el reactivo de trabajo es estable30 días en refrigerador (2-10°C)AA líquida: estable en refrigerador (2-10°C)hasta fecha de vto. indicada en la caja.
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
0 - 150 mg/dl
LINEALIDAD
1000 mg/dl (10 g/l)
Wiener lab.
71Rev. Diciembre 2004
TEST NAME TRIG TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG END PT DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR 1.000 *
SAVE
% TOL OF CAL FACTOR 10 % TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
C1 x.x # 1 DEFINE
C2 x.x # 1 REAGENT
C3 x.x # 1
0.00000 0
0.00000 0
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST TRIGLICERIDOS
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NAME TRIG LINEARITY (C) 5.00000 TO 1000.0 CANCEL
LOT TD INITIAL Ad 0.300
ABS LIMIT (Ad) 1.00
REAGENT VOL (uL) NORM 236
LOW 0.000 HIGH 236 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 300 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 360 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / 604 A 1.00 0.000 0.000 0.000
500 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
# Valor asignado al calibrador
Wiener lab.
72Rev. Diciembre 2004
CCXUREA
TEST PARAMETERS Wiener lab.
ENTRY NAME UREA SAMPLE (uL) NORMAL 3
REPORT NAME UREA LOW 0.000 HIGH 1.50 NEXT
RATIO REF UREA TEST
TEST NUMBER UNITS PRIM MG/DL SEC
TEST TYPE CALIBRATED SEC. UNITS FACTOR DELETE
MATH LIN REG END PT PRINT DIGITS 0 TEST
REACTION DIRECTION DOWN
REAGENTS 1 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL (C) 10 TO 50 SAVE
TEST BLANK TYPE REAGENT BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME DEFINE
CALIB
RATE C. OF. C. 0.00000 DEFINE
AUTO PRINT OFF EXIT
RUNNING TEST DEFINITION STATUS
CALIBRACION
Emplear Calibrador.
* Para obtener el valor de referencia del factor es
conveniente correr tres veces la calibración y sacar el
promedio.
CONTROL DE CALIDAD
Standatrol SE 2 nivelesWiener lab.
VALORES DE REFERENCIA
10 - 50 mg/dl
LINEALIDAD
250 mg/dl (2,5 g/l).
REACTIVOS PARA UREA
Urea UV AAPresentación: 10 x 20 mlCód.: 1810322Presentación: 4 x 50 mlCód.: 1810323Urea UV AA líquidaPresentación: 4 x 100 ml R1 + 4 x 25 ml R2Cód.: 1810324Presentación: 4 x 200 ml R1 + 1 x 200 ml R2Cód.: 1810328
PREPARACION
Observar las instrucciones del manual queacompaña al equipo.
ESTABILIDAD DEL REACTIVO
Una vez preparado el Reactivo de Trabajo,es estable 30 días en refrigerador (2-10°C)
Wiener lab.
73Rev. Diciembre 2004
TEST NAME UREA TEST TYPE CALIBRATED
COMB TEST MATH MODEL LIN REG END PT DELETE
CAL MODE CAL ON CMD CAL INTERVAL (HR) CALIB
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR - 300.000 *
SAVE
% TOL OF CAL FACTOR 10 % TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
MCC1 x.xxx' # 1 DEFINE
MCC2 x.xxx' # 1 REAGENT
MCC3 x.xxx' # 1
AUTO PRINT OFF EXIT
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NUMBER 1 FOR TEST UREA
REAGENT NAME UREA LINEARITY (C) 6.00000 TO 250.00 CANCEL
LOT TD INITIAL Ad 0.900
ABS LIMIT (Ad) 0.200
REAGENT VOL (uL) NORM 300
LOW 0.000 HIGH 300 BEFORE WASH CYCLES 18
FIRST READ TIME (SEC) 300 AFTER WASH CYCLES 18
LAST READ TIME (SEC) 360 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
READ INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / 380 A 1.00 0.000 0.000 0.000
340 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
# Valor asignado al calibrador
Wiener lab.
74Rev. Diciembre 2004
TEST PARAMETERS Wiener lab.
ENTRY NAME ASO SAMPLE (uL) NORMAL 3.00
REPORT NAME ASO LOW 0.000 HIGH 2.00 NEXT
RATIO REF ASO TEXT
TEST NUMBER UNITS PRIM UI/ML SEC
TEST TYPE AUX SEC. UNITS FACTOR DELETE
MATH 1 PT CAL FACT END PT PRINT DIGITS 0 TEST
REACTION DIRECTION U P
R E A G E N T S 2 INST MUL 1.00000 INT 0.00000
TEMPERATURE (C) 37 NORMAL(C) 0 TO 200 SAVE
TEST BLANK TYPE AUX SERUM BLANK TEST
COMB TEST NAME SAMPLE DISP DELAY (SEC) 0
EDIT TIME
D E F I N E
RATE C. OF C. 0.00000 CALIB
D E F I N E
AUTO PRINT OFF
RUNNING TEST DEFINITION STATUS
CCXASO
REACTIVOS PARA ASO
ASO latex turbitest AAPresentación: 12 ml buffer + 15 ml látexCód.: 1073261
PREPARACION
Reactivos listos para usar.
ESTABILIDAD DEL REACTIVO
Los Reactivos son estables en refrigerador(2-10°C) hasta la fecha de vto. indicada en lacaja.
CALIBRACION
Emplear Calibrador ASO turbitest AA
* Para obtener el valor de referencia del
factor es conveniente correr tres veces la
calibración y sacar el promedio.
CONTROL DE CALIDAD
Control Inmunológico Nivel 1Wiener lab.
VALORES DE REFERENCIA
0 - 200 UI/ml
LINEALIDAD
1000 UI/ml
Wiener lab.
75Rev. Diciembre 2004
REAGENT NUMBER 1 FOR TEST ASO
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
RUNNING LINEAR MODEL CALIBRATION DEFINITION STATUS
TEST NAME ASO TEST TYPE AUX
COMB TEST MATH MODEL 1PT CAL FACT END PT DELETE
CALIB
CAL MODE CAL ON CMD CAL INTERVAL (HR)
INTCPT TOL (C) -1000.00 TO 1000.00 REF CAL FACTOR *
SAVE
% TOL OF CAL FACTOR 10 %TOL OF CAL 10 CALIB
CAL LEVEL 0
CALIBRATOR LEVEL (C) REPLICATES
WATER 0.00000 1
CAL ASO XX # 1
0 DEFINE
0 REAGENT
0
AUTO PRINT OFF EXIT
# Valor asignado al calibrador
REAGENT NAME ASO 1 LINEARITY (C) 20 TO 1000.0 CANCEL
LOT TD INITIAL Ad 1.700
ABS LIMIT (Ad) 3.000
REAGENT VOL (uL) NORM 110
LOW 0.0000 HIGH 110 BEFORE WASH CYCLES 5
FIRST READ TIME (SEC) 0 AFTER WASH CYCLES 5
LAST READ TIME (SEC) 0 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
D INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 60.0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
604 / MA A 1.00 0.000 0.000 0.000
604 / MA A 1.00 0.000 0.000 0.000
604 / MA A 1.00 0.000 0.000 0.000
604 / MA A 1.00 0.000 0.000 0.000
604 / MA A 1.00 0.000 0.000 0.000
604 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF
Wiener lab.
76Rev. Diciembre 2004
REAGENT NUMBER 2 FOR TEST ASO
RUNNING TEST PARAMETER FILE: REAGENT DEFINITION STATUS
REAGENT NAME ASO 2 LINEARITY (C) 20 TO 1000.0 CANCEL
LOT TD INITIAL Ad 1.700
ABS LIMIT (Ad) 3.00
REAGENT VOL (uL) NORM 170
LOW 0.0000 HIGH 170 BEFORE WASH CYCLES 5
FIRST READ TIME (SEC) 300 AFTER WASH CYCLES 5
LAST READ TIME (SEC) 300 MIX TIME (SEC) 1.00
NUMBER OF READS 1 COOLING YES
D INTERVAL (SEC) 60.0 CONSTANT INTERCEPT 0.00000
AUX REAG DISP (SEC) 0 CORRECTION LIMIT 0.00000 SAVE/NEXT
RSM 0 SPECTRAL CORRECTION REAGENT
PRIM SEC USE IN CONST E.F. LOW HIGH
604 / MA A 1.00 0.000 0.000 0.000
604 / MA A 1.00 0.000 0.000 0.000
604 / MA A 1.00 0.000 0.000 0.000
604 / MA A 1.00 0.000 0.000 0.000
604 / MA A 1.00 0.000 0.000 0.000
604 / MA LE 1.00 0.000 0.000 0.000
AUTO PRINT OFF