meter mounting equipment commonwealth edison

36
Meter Mounting Equipment Commonwealth Edison

Upload: others

Post on 03-Feb-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Meter Mounting Equipment Commonwealth Edison

Meter Mounting Equipment

Commonwealth Edison

Page 2: Meter Mounting Equipment Commonwealth Edison

MIL

BA

NK

OV

ERV

IEW

MILBANK OVERVIEW2

2

Charles A. Milbank1879-1966

Bill Martin1916-1998

Robert F. Waldrop1922-2002

Robert F. Waldrop, IIChairman

Katrina Waldrop HenkeVice Chairman

Milbank–Quality Metering Products for 80 Yearsilbank ManufacturingCompany was estab-lished in 1927 byCharles A. Milbank.

Originally, the company manu-factured high voltage switches;however, by 1941 Milbank devot-ed itself primarily to the manufac-ture of sheet metal enclosuresand related equipment for theelectrical generation and distribu-tion industry. Today we are anindustry leader in the manufac-ture of electrical meter sockets.Through a national network ofmanufacturer’s representatives weprovide wholesale electrical dis-tributors with quality electricalproducts for the utility, contractor,industrial and OEM markets.

As the meter standards havechanged, Milbank has been suc-cessful in adapting its productline to these changes. Our fullscale engineering departmentdesigns products to meet cus-tomer specifications and satisfyall utility requirements.Milbank’s employee base of over1,000 workers, along with ourfive manufacturing facilities com-

prising almost 550,000 squarefeet give us the flexibility toschedule, produce, and shiporders quickly. Currently,Milbank manufactures over10,000 different catalog items,and this list continues to grow.Our unique product offeringincludes: Residential &Commercial Meter Sockets;Residential & Commercial MeterPedestals; RV/MH Power Outlets,S e r v i ce Pede s t a l s , andTransformers; Commercial &Industrial Electrical Enclosures;Circuit Breakers; Disconnects &Safety Switches; Safety Sockets;Utility & Residential SecondaryPedestals; Hubs, and relatedaccessories. If you don’t find aunit in this catalog to service yourneeds, send us your specificationsand we will be happy to workwith you.

Our success has come from aloyal customer base that can relyon us to build quality products ata fair price in a timely manner.Our willingness and ability todesign and produce new productsto meet our customer demands is

an important factor to remaincompetitive in today’s electricalmarket.

Milbank has been serving theelectric utility & wholesale distri-bution industries for 80 yearswith innovative, quality engi-neered products. So rememberus for all of your meter mountingand related requirements, andwe will be happy to serve you aswe have in the past–with depend-able service and quality products!

We take great pride in beingone of the few family-ownedbusinesses left in our industry.We are a third generation runbusiness and truly believe that...

FAMILY MAKES A DIFFERENCE!

M

Page 3: Meter Mounting Equipment Commonwealth Edison

3TA

BLE O

F CO

NTEN

TSTABLE OF CONTENTS

CATALOG NUMBER LOGIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

DISCONNECTSAIR CONDITIONER DISCONNECT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5AIR CONDITIONER DISCONNECT WITH GFCI RECEPTACLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6HOT TUB DISCONNECT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

SINGLE POSITION100 & 200 AMP—4 & 5 TERMINAL—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

SINGLE POSITION (LEVER BYPASS)200 AMP— 5 & 7 TERMINAL—JAW CLAMPING LEVER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8320 AMP—4 TERMINAL—JAW CLAMPING LEVER—HEAVY DUTY—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

MULTIPLE POSITION (HORIZONTAL GANGS)100 AMP / POSITION—4 TERMINAL—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14200 AMP / POSITION—4 TERMINAL—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14200 AMP / POSITION—7 TERMINAL—JAW CLAMPING LEVER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

CONDOMINIUM METERING BANKS125 & 200 AMP / POSITION—VERTICAL & RECTANGULAR—OVERHEAD/UNDERGROUND SERVICE . . . . . . . . . . . . . 16-17

METER MAINS100 AMP—4 TERMINAL—METER MAIN—PLUG-IN—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9200 AMP—4 TERMINAL— METER MAIN— RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9200 AMP—7 TERMINAL— METER MAIN— RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10100, 150 & 200—4 TERMINAL— METER MAIN— 22K AIC— RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-13100/200 AMP—4 TERMINAL—METER MAIN PEDESTAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19320 AMP—4 TERMINAL— MAIN PEDESTAL— LEVER BYPASS—W/ BREAKER—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . 22

PEDESTALS100 / 200 AMP—4 TERMINAL—SINGLE POSITION—RESIDENTIAL—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18100 / 200 AMP—4 TERMINAL—DOUBLE POSITION—RESIDENTIAL—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18100/200 AMP—5 & 7 TERMINAL—HEAVY DUTY—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23JOINT USE TERMINATION CABINET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24U5706 TEMP TO FINAL SERVICE PEDESTAL—RINGLESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21

TRANSFORMER RATED SOCKET20 AMP—6, 8 & 13 TERMINAL—INSTRUMENT TRANSFORMED RATED SOCKET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

COMMERCIAL METER PEDESTALCOMMERCIAL METER PEDESTAL OVERVIEW, APPLICATIONS & ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-27

MISCELLANEOUSACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-29CONDUIT AND AMPACITY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30ENERGIZATION OF ELECTRICAL EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31MATERIALS AND FINISHES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

ADDITIONAL MILBANK PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

3

Page 4: Meter Mounting Equipment Commonwealth Edison

CATALOG NUMBER LOGIC4C

ATA

LOG

NU

MB

ER L

OG

IC

4

Page 5: Meter Mounting Equipment Commonwealth Edison

530 &

60 AM

P–FUSIB

LE / NO

N-FU

SIBLE–A

IR C

ON

DITIO

NER

DISC

ON

NEC

TS30 & 60 AMP–FUSIBLE / NON-FUSIBLE–AIR CONDITIONER DISCONNECTS

5

U3800(No deadfront required)

Milbankʼs air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Ourcompact design meets all wire bending space requirements in the NEC and, also, complies with article440-14 in the NEC. To insure the safest conditions, we designed our disconnect pullers to be remov-able or they may be reinstalled in the off position. Another safety feature is the padlock provision on thefront cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel andfinished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxyand polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. Thisoffers a durable, nonfading finish.

TECHNICAL INFORMATION

AMP TYPE CATALOGNUMBER

MAXH.P.

WT.@#

30 FUSIBLE U3830 3 2.7

60 FUSIBLE U3860 10 3.3

60 NONFUSIBLE U3800 10 3.25

LINE & LOADWIRE RANGE

GROUNDWIRE RANGE DIMENSIONS WIRE RATING

CU AL CU/AL

#14-#3AWG

#14-#3AWG #14-3 AWG

#14-#3AWG

#14-#3AWG #14-3 AWG

#14-#2AWG

#12-#2AWG #14-3 AWG

D" W" H" CU °C AL °C

2-5/8 5 7 60°/75° 60°/75°

3 5 91⁄4 60°/75° 60°/75°

3 5 8 60°/75° 60°/75°

PROFILE

U/L listed as Enclosed Pullout Switch

1∅, 240 VAC

Type 3R Rainproof

Six one-inch concentric knockouts

U3801

U3860

60 NONFUSIBLE U3801 10 2.5 #14-#3AWG

#14-#3AWG #14-3 AWG 2-3/8 5 6-3/4 60°/75° 60°/75°

Page 6: Meter Mounting Equipment Commonwealth Edison

AC DISCONNECT / SPA BOX6A

C D

ISC

ON

NEC

T /

SPA

BO

X

6

• Meets NEC # 210.63 Requirements *• UL Listed as Power Outlet• Type 3R Enclosure• In-Use Cover**• Duplex Ground Connector• 1” Concentric Knockouts

AC DISCONNECT• 1∅, 240 Volt• 60 amp, Non-Fused

GFCI RECEPTACLE• 20 amp• Reset/Test Button• Padlock provision

Combination AC Disconnect / 20 Amp GFCI Receptacle–Together in 1 Box

To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position.All units are designed with a padlock provision on the cover for security.

**Note: U3822-20GR cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle).*Reprinted with permission from NFPA 70-2002, National Electrical Code®, Copyright 2001, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the completeand official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code® and NEC® are registered trademarks of theNational Fire Protection Association, Quincy, MA.

* NEC® #210.63 Heating, Air-Conditioning and RefrigerationEquipment Outlet. ...The receptacle shall be locat-ed on the same level and within7.5 m (25 ft.) of the heating, air-conditioning and refrigerationequipment.

* NEC® #210.08 Ground-FaultCircuit– Interruptor protectionfor personnel.

U4881-O-50GB

AMP TYPE CATALOGNUMBER

WT.@#

– BREAKERPROVISION U4881-O 7

LINE & LOAD CONNECTORWIRE RANGE

GROUND CONNECTORWIRE RANGE DIMENSIONS

CU AL CU/AL

#14-1/0 #14-1/0 #14-1/0

D″ W″ H″

3 3⁄4 71⁄2 81⁄2

50

60

BREAKER

BREAKER

U4881-O-50GB

U4881-O-60GB

8

8

#14-1/0

#14-1/0

#14-1/0

#14-1/0

#14-1/0

#14-1/0

3 3⁄4

3 3⁄4

71⁄2

71⁄2

81⁄2

81⁄2

• 240 Volt ground fault protection• UL listed, Type 3R rainproof• Milbank reliability• Easy installation• 2 pole, 50 or 60 amp GFCI breaker protection• Compact size:

8-1/2” H x 7-1/2” W x 3-3/4” D• 3 or 4 wire installation• 1∅, 120 / 240 VAC• Standard package of 12• 2 extra one-pole breaker spaces• 100 amp overall rating

Sub Panel Breaker Enclosure• Use as a 100 amp, 4 circuit sub panel

enclosure• U4881-O has provision for (2) 2-pole or

(4) 1-pole small frame breakers

Hot Tub Disconnect or Sub Panel Breaker Enclosure–Type 3RSpa Box with GFCI Protection

U3822-20GR

60 amp, Non-Fused AC Disconnect

Duplex 20 ampGFCI Receptacle

Type 3REnclosure withIn-Use Cover

AMP TYPE CATALOGNUMBER

MAXH.P.

WT.@#

60 NONFUSIBLE U3822-20GR 10 6

LINE & LOAD CONNECTORWIRE RANGE

GROUND CONNECTORWIRE RANGE DIMENSIONS WIRE RATING

CU AL CU/AL

#14-#2AWG

#12-#2AWG #14-4 AWG

D″ W″ H″ CU °C AL °C

4.8 5.25 7.4 60°/75° 60°/75°

Page 7: Meter Mounting Equipment Commonwealth Edison

7100 / 200 AMP–4 & 5 TERMINAL–RINGLESS–600 VAC

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

7

1 2

544 3

AMP

100/200

SERVICE CATALOGNUMBER

HUB

OH U8949-RL-TG-KK H.O.

CONNECTORSCU/AL

LINE LOAD

BY-PASS

HORN

DIMENSIONS CONCENTRIC K.O.ʼS

1 2 3 4 5

21⁄2 21⁄2 21⁄2 11⁄4 1⁄4

D″ W″ H″

41⁄8 8 151⁄2#6-350 kcmil #6-350 kcmil

100 / 200 AMP—4 & 5 TERMINAL—RINGLESS—1∅—600 VAC

U8949-RL-TG-KK

HUBS: Order hubs separately–see accessory page for ordering information.FIFTH TERMINAL: For field mounted fifth terminal, order catalog number K5T to fit into square opening in the 9 oʼclock position.INSULATED NEUTRAL: For indoor service order as extra #BL1048-KK complete interior block assembly to be installed to provide

insulated neutral.

CECHAAPPROVED

100 / 200 AM

P–4 & 5 TER

MIN

AL–R

ING

LESS–600 VA

C

8949

Page 8: Meter Mounting Equipment Commonwealth Edison

200 & 320 AMP–4, 5 & 7 TERMINAL–LEVER BYPASS–RINGLESS–600 VAC820

0 &

320

AM

P–4,

5 &

7 T

ERM

INA

L–LE

VER

BY

PASS

–RIN

GLE

SS–6

00 V

AC

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

8

#OF

TERMS

5

PHASE CATALOGNUMBER

SERVICE

3∅3W U8624-RXL OH

CONNECTORSCU/AL

LINE & LOAD

BY-PASS

LEVER

DIMENSIONS CONCENTRIC K.O.ʼS

1 2 3 4 5

3 21⁄2 3 3 1⁄4

6

1⁄4, 1⁄2

D″ W″ H″

47⁄8 13 19#6-350 kcmil

7 3∅4W U8606-RXL OH

HUB

C.P.

C.P. LEVER 3 21⁄2 3 3 1⁄4 1⁄4, 1⁄247⁄8 13 19#6-350 kcmil

200 AMP—5 & 7 TERMINAL—RINGLESS—3∅—600 VAC

1 2

34 465

U8624-RXL

HUBS: Order hubs separately–see accessory page for ordering information.BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.CONNECTORS: Units supplied with extruded aluminum connectors and bonded triplex neutral.INSULATED NEUTRAL: For insulated neutral order catalog number K1047 (for the U8606 only). U8624 can be field converted

to isolated neutral by removing the bonding link.

BYPASS: Lever supplies clamping action and also operates bypass device. CONNECTORS: Supplied with 3/8″-16 hex head nuts with Belleville washers. For connector kits, order as extra: K1539

(350kcmil) or K1540 (600 kcmil). For twin lug connectors order as extra: K1350 (350 kcmil). Separate kits are required for bothline and load.

FIFTH TERMINAL: For factory installed fifth terminal in the 6 oʼclock position add the suffix -5T6 to the catalog number. Forfactory installed fifth terminal in the 9 oʼclock position at the suffix -5T9 to the catalog number. For field installed fifth terminalorder catalog number K3865.

862486064363

U4363-X-QG-CECHA

320 AMP CONTINUOUS (400 AMP MAX)—4 TERMINAL—HEAVY DUTY—RINGLESS—1∅—600 VAC

CECHAAPPROVED

PHASE CATALOGNUMBER

SERVICE HUB BY-PASS

DIMENSIONS CONCENTRIC K.O.ʼS

1 2 3 4 5 6D″ W″ H″

1∅

TERMS

4 U4363-X-QG-CECHA C.P. 3⁄8″ x 16 STUDS LEVER 3 3 3 3 1⁄4 1⁄4, 1⁄247⁄8 13 281⁄4OH

CONNECTORSCU/AL

Page 9: Meter Mounting Equipment Commonwealth Edison

9100 OR 200 AMP–CIRCUIT BREAKER MAIN DISCONNECTSINGLE POSITION–METER MAIN–240 VAC

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

9

U7375-RL-KK U7607-RL-200-KK(Supplied with 200 Amp circuit breaker)

CATALOGNUMBER

U7375-RL-KK

SERVICE

OH

HUB

H.O.

CONNECTORSCU/AL

LINE LOAD

#6-2/0 C.B.

BY-PASS

HORN

DIMENSIONS CONCENTRIC K.O.ʼS

1D″ W″ H″

11⁄433⁄4 81⁄8 22

2

11⁄4

3

11⁄4

4

1⁄4,1⁄2

5

100 AMP–4 TERMINAL—METER MAIN (PLUG-IN)—RINGLESS—1∅

CATALOGNUMBER

U7607-RL-200-KK

SERVICE

OH

HUB

H.O.

CONNECTORSCU/AL

LINE LOAD#6-350kcmil

#1-300kcmil

BY-PASS

HORN

DIMENSIONS CONCENTRIC K.O.ʼS

1D″ W″ H″

241⁄2 81⁄8 29

2

2

3

2

4

1⁄4,1⁄2

5

200 AMP–4 TERMINAL—METER MAIN—RINGLESS—1∅

CIRCUIT BREAKER: Main circuit breaker not supplied with unit. For 100 amp service order Milbank catalog numberQ2100 separately. See circuit breaker chart on accessory page for other compatible models.

CIRCUIT BREAKER: 200 amp main circuit breaker factory bussed. Order Milbank catalog number UQFB-200-X1 forreplacement. Other amperages available. See Milbank circuit breaker chart on accessory page.

HUBS: Order hubs separately–see accessory page for ordering information.FIFTH TERMINAL: For field mounted fifth terminal for U7375 order catalog number 5T8K2. For field mounted fifth

terminal for U7607 order catalog number K5T. Mount in the 9 oʼclock position only.

2

3

M I L B A N K

4

1

CECHAAPPROVED

100 OR

200 AM

P–CIR

CU

IT BR

EAK

ER M

AIN

DISC

ON

NEC

T–SING

LE POSITIO

N–M

ETER M

AIN

–240 VA

C

Page 10: Meter Mounting Equipment Commonwealth Edison

200 AMP–7 TERMINAL–RINGLESS–METER MAIN–3Ø10

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

10

CATALOGNUMBER

U5750-RXL-200-BL-CECHA

SERVICE

OH/UG

HUB

C.P.

CONNECTORSCU/AL

LINE LOAD

#6-350 C/B

BY-PASS

LEVER

DIMENSIONS CONCENTRIC K.O.ʼS

1D″ W″ H″

11⁄4-353⁄4 173⁄8 34

2

3-4

3

1⁄2-2

7 TERMINAL–METER MAIN–RINGLESS–3Ø4W–RINGLESS

BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.BREAKER: Factory installed 200 amp, 3-pole, 10,000 AIC.SIDE WIREWAY: Allows for overhead or underground installation.

200

AM

P–7

TER

MIN

AL–

RIN

GLE

SS–M

ETER

MA

IN–3

Ø

U5750-RXL-200-BL-CECHA

2

1

13

5750

CECHAAPPROVED

NEW

PRODUCT

Page 11: Meter Mounting Equipment Commonwealth Edison

11100, 150 & 200 AMP–4 TERMINAL–300 VAC–METER MAIN

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

11

100, 150 & 200 AMP–4 TERMINAL–METER MAIN–OVERHEAD/UNDERGROUND–22K AIC–1∅3W

AMPS CATALOGNUMBER

HUBCONNECTORS

LINE LOADBY-

PASS

DIMENSIONS CONCENTRIC K.O.ʼS

1 2 3 4 5 6D″ W″ H″

HUB: Supplied with (2) closing plates packed inside. Order hubs as a separate item. See accessory page for hub options.INTERIOR: U5168 units have 8 circuit interior.FIFTH TERMINAL: Order K5T and field install for 208Y/120 network systems. Installs in the 9 oʼclock position only. BREAKERS: Rated 22K AIC with Milbank QNR2200H main installed.INTERLOCK KIT: For generator auxiliary circuit breaker interlock, order K5815 for large QN with small frame Q; order K5820 for large

frame QN with large frame QN.*SUB-FEED LUGS: #6-350 kcmil sub-feed lugs provided on 8 circuit interior.

2

354

5

11

5

6

6

5

6

8100 U5168-XTL-100-KK-CECHA C.P. HORN 2 2 3 21⁄2 1⁄2,3⁄441⁄2 141⁄8 32#6-350 kcmil #1/0-300 kcmilBreaker*

1⁄2,3⁄4, 1

8150

200

U5168-XTL-150-KK-CECHA

U5168-XTL-200-KK-CECHA

C.P.

C.P.

HORN

HORN

2

2

2

2

3

3

21⁄2

21⁄2

1⁄2,3⁄41⁄2,3⁄4

41⁄2

41⁄2

141⁄8

141⁄8

32

32

#6-350 kcmil

#6-350 kcmil

#1/0-300 kcmilBreaker*

#1/0-300 kcmilBreaker*

1⁄2,3⁄4, 11⁄2,3⁄4, 1

U5168-XTL-200-KK

5168

NO. OFCIRCUITS

8

AMPS CUTLER-HAMMER(WESTINGHOUSE)

SIEMENS(ITE)

SIEMENSMURRAY /

CROUSE-HINDSG.E. SQ-D

125-200 HQP / BR / WBJ — MD THQ —

≤ 100 QP / BR / HQP QP MP THQ HOMELINE

Amperage

Catalog No.

100 150 200

Q2100H QN2150RH QN2200RH

PLUG-IN BREAKER COMPATIBILITY CHARTMAIN CIRCUIT BREAKER CHART

100, 150 & 200 A

MP–4 TER

MIN

AL–300 V

AC

–METER

MA

IN

CECHAAPPROVED

Page 12: Meter Mounting Equipment Commonwealth Edison

200 AMP–4 TERMINAL–RINGLESS–METER MAIN1220

0 A

MP–

4 TE

RM

INA

L–R

ING

LESS

–MET

ER M

AIN

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

12

SPECIFICATIONS• Listed under UL 67 as “suitable only for use as service equipment” – file number E32628 Series 1800 MS.

• 200 amp continuous duty ringless meter socket. Accepts ANSI type C12.10 watt-hour meters. Overall ampere

rating limited to main circuit breaker rating.

• For use on 120/240 volt single phase applications.

• 22K AIC as standard.

• Type 3R enclosure constructed with G90 galvanized steel.

• Light gray polyester powder coat finish.

• Service entrance overhead or underground. OH has up to 2-1/2” hub opening and UG has up to 3” knockout

• Wire terminations accept copper or aluminum conductors:

Line & Neutral: # 1/0-350 kcmil Ground: #6-350

• Plug-on main circuit breaker: 60 and 100 amp type Q small frame, 150 and 200 amp type QN large frame.

• Lockable breaker reset cover.

U5842KO CONFIGURATIONS

A 1.0” 1.25” 1.5” 2.0” 2.5” CONC. B 0.25” 0.5” CONC.C 0.25” SOLID

CECHAAPPROVED

Page 13: Meter Mounting Equipment Commonwealth Edison

13U

5842 OR

DER

ING

INFO

RM

ATIO

NU5842 ORDERING INFORMATION

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

13

RINGLESS METER MAIN MODELS

Catalog Number Amp Main Term Service Wt (#)

◆ U5842-RL-KK 200 2p* 4 OH 25

*2 Pole provision.

AIC RATING: All models are rated 22K AIC.

FIFTH TERMINAL: For field installable 208Y/120 network service order K5T. Installs in the 9 oʼclock position.

MAIN CIRCUIT BREAKER CHART

Amperage 60 100 150 200

10KAIC Breaker Model Q260 Q2100 QN2150 QN2200

22KAIC Breaker Model Q260H Q2100H QN2150H QN2200H

OH-112993

OH-1132161 (100A)OH-1130010 (200A)

FIFTH TERMINALK5T

(New style block with square hole)

Page 14: Meter Mounting Equipment Commonwealth Edison

100 & 200 AMP / POSITION–4 TERMINAL–HORIZONTAL GANG–RINGLESS–300 VAC1410

0 &

200

AM

P /

POSI

TIO

N–4

TER

MIN

AL–

HO

RIZ

ON

TAL

GA

NG

–RIN

GLE

SS–3

00 V

AC

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

14

334 5 5

211

NO.OF

POS.

2

CATALOGNUMBER

L572-XL-KK

HUB

C.P.

CONNECTOR CU/AL BY-

PASS

HORN

DIMENSIONS CONCENTRIC K.O.ʼS

1

2 2 2 21⁄21⁄4,1⁄2

2 3 4 5D″

41⁄2

W″

205⁄16

H″

16

LINE

#2-350kcmil

LOAD

#6-2/0

3 L573-XL-KK C.P. HORN 2 2 2 21⁄21⁄4,1⁄241⁄2 281⁄2 16#2-350

kcmil #6-2/0

4 L574-XL-KK C.P. HORN 2 2 2 21⁄21⁄4,1⁄241⁄2 4011⁄16 16#2-350

kcmil #6-2/0

5 L575-XL-KK C.P. HORN 2 2 2 21⁄21⁄4,1⁄241⁄2 487⁄8 16#2-350

kcmil #6-2/0

6 L576-XL-KK C.P. HORN 2 2 2 21⁄21⁄4,1⁄241⁄2 571⁄16 16#2-350

kcmil #6-2/0

AMPS

100

100

100

100

100

100 AMP / POSITION— 4 TERMINAL—RINGLESS—1∅3W—OVERHEAD

4” SIDE WIREWAYOH SERVICE

FIFTH TERMINAL: For factory installed fifth terminal in the 9 oʼclock position for the U1252 series add the suffix -5T. Forfield mounted fifth terminal, order catalog number K5T, 9 oʼclock position only. For field installed fifth terminal for theL572 series order as extra 5T8K2 for 6 oʼclock position, and K9959 for 9 oʼclock position.

BUSSING: Bussing is 5/16″ x 1″ aluminum on U1252 & U1253, 3/8”x1” aluminum on U1254-1256. Refer to the conduit &ampacity information page for information on ampacity of bussing.

*UNDERGROUND PEDESTALS: (U1252-U1256 only) For underground service order S2291-TO pedestal raceway. A 12″pedestal extension kit is also available. Order catalog number S2571.

*FOR OVERHEAD SERVICE: The U1254-U1256 units are factory assembled for underground service. If overhead serv-ice is desired an extension kit is required. Order catalog number K3923 for the U1254 and U1255 units and K3955 for theU1256 unit.

200 AMP / POSITION—4 TERMINAL—RINGLESS—1∅3W—OVERHEAD / UNDERGROUND*

NO.OF

POS.

CATALOGNUMBER HUB

CONNECTOR CU/AL BY-

PASS

DIMENSIONS CONCENTRIC K.O.ʼS

1 2 3 4 5D″ W″ H″LINE LOAD

2 U1252-X-KK-K1-PED C.P. HORN 21⁄2 21⁄2 21⁄23⁄8 PED51⁄8 261⁄2 14#6-350

kcmil#6-350kcmil

3 U1253-X-KK-K3-PED C.P. HORN 21⁄2 21⁄2 21⁄23⁄8 PED51⁄8 3411⁄16 14#4-600

kcmil#6-350kcmil

4 U1254-X-KK-K3-PED C.P. HORN 21⁄2 21⁄2 21⁄23⁄8 PED51⁄8 427⁄8 16#4-600

kcmil#6-350kcmil

5 U1255-X-KK-K4-PED C.P. HORN 21⁄2 21⁄2 21⁄23⁄8 PED51⁄8 547⁄8 16(2)#2-600

kcmil#6-350kcmil

6

AMPS

200

200

200

200

200 U1256-X-KK-PED C.P. HORN 21⁄2 21⁄2 21⁄23⁄8 PED51⁄8 631⁄16 183/8″-16

STUD#6-350kcmil

1 1 2

34 453 1252-6L572-6

L572-XL-KKU1252-X-KK-K1(shown without

pedestal)

CECHAAPPROVED

Page 15: Meter Mounting Equipment Commonwealth Edison

15200 A

MP / PO

SITION

–7 TERM

INA

L–HO

RIZ

ON

TAL G

AN

GS–JA

W C

LAM

PING

LEVER

–RIN

GLESS–600 V

AC

200 AMP / POSITION–7 TERMINAL–HORIZONTAL GANGSJAW CLAMPING LEVER–RINGLESS–600 VAC

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

15

NO.OF

POS.

2

CATALOGNUMBER

U2732-XT-PED

HUB

(2)C.P.

CONNECTOR CU/AL BY-

PASS

LEVER

DIMENSIONS CONCENTRIC K.O.ʼS

1

21⁄2 21⁄2 PED 21⁄2 1⁄4,1⁄2

2 3 4 5D″

6

W″

321⁄8

H″

251⁄4

LINE

3/8″-16STUD

LOAD

#6-350kcmil

3 U2733-XT-PED (2)C.P. LEVER 21⁄2 21⁄2 PED 21⁄2 1⁄4,1⁄26 423⁄16 251⁄4

3/8″-16STUD

#6-350kcmil

4 U2734-XT-PED (2)C.P. LEVER 21⁄2 21⁄2 PED 21⁄2 1⁄4,1⁄26 521⁄4 251⁄4

3/8″-16STUD

#6-350kcmil

5 U2735-XT-PED (2)C.P. LEVER 21⁄2 21⁄2 PED 21⁄2 1⁄4,1⁄26 625⁄16 251⁄4

3/8″-16STUD

#6-350kcmil

6 U2736-XT-PED (2)C.P. LEVER 21⁄2 21⁄2 PED 21⁄2 1⁄4,1⁄26 723⁄8 311⁄4

3/8″-16STUD

#6-350kcmil

SERV.

OH/UG

OH/UG

OH/UG

OH/UG

OH/UG

AMPS

200

200

200

200

200

200 AMP —7 TERMINAL—RINGLESS—3∅4W—OVERHEAD/UNDERGROUND*

HUBS: Units supplied with two closing plates. To order hubs as extra refer to the hub suffix chart on the accessorypage.

BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.*CONNECTOR KITS: Line wire sections supplied with studs. For connector kits order K3082 (single-350 kcmil),

K3441 (single-600 kcmil), or twin K3442 (twin-350 kcmil) or K3083 (twin-600 kcmil). Line connectors can bereversed to change from “OH” to “UG” service.

*UNDERGROUND PEDESTALS: For underground service order S2291-TO pedestal raceway. A 12″ pedestal exten-sion kit is also available. Order catalog number S2571.

BUSSING: Bussing is 3/8″ x 1″ aluminum. Refer to the conduit & ampacity information page for information onampacity of bussing.

1 1 1 2

4 453

U2732-XT-PED(shown without pedestal)

CENTER WIREWAY

CECHAAPPROVED

Page 16: Meter Mounting Equipment Commonwealth Edison

CONDOMINIUM METERING BANKS–RINGLESS–OH/UG SERVICE–1∅3W–120/240 VAC16C

ON

DO

MIN

IUM

MET

ERIN

G B

AN

KS–

RIN

GLE

SS–O

H/U

G S

ERV

ICE–

1∅3W

–120

/240

VA

C

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

16

CATALOGNUMBER

NO.OF

POS.

2

3

MAIN BUSRATING

LINECONNECTOR

SIZE

U2852-X-KK-K1-PED 200 amp

U2853-X-KK-K1-PED 200 amp

#6-350 kcmil

#6-350 kcmil

CATALOGNUMBER

NO.OF

POS.

4

5

MAIN BUSRATING

LINECONNECTOR

SIZE

U2854-X-KK-PED 400 amp

U2855-X-KK-PED 400 amp

*3/8″-16 STUD

*3/8″-16 STUD

6 U2856-X-KK-PED 400 amp *3/8″-16 STUD

CATALOGNUMBER

NO.OF

POS.

4

5

MAIN BUSRATING

LINECONNECTOR

SIZE

U2864-X-KK-PED 400 amp

U2865-X-KK-PED 600 amp

*3/8″-16 STUD

*3/8″-16 STUD

6 U2866-X-KK-PED 600 amp *3/8″-16 STUD

CATALOGNUMBER

NO.OF

POS.

2

3

MAIN BUSRATING

LINECONNECTOR

SIZE

U2862-X-KK-K1-PED 250 amp

U2863-X-KK-K1-PED 300 amp

#6-350 kcmil

#6-350 kcmil

SIZE SUFFIX

SINGLE

TWIN

K1539-K1

-K3

-K2

-K4

K1540

K1350

K1541

U2852-56U2862-66

U2854-56U2864-66

U2854-56U2863-66

U2864-66

#6-350kcmil

#4-600kcmil

#6-350kcmil

#2-600kcmil

KITNUMBER

COMPATIBLEWITH

WIRERANGE

125 AMP/POSITION 200 AMP/POSITION

125 AMP/POSITION 200 AMP/POSITION

CONNECTOR KITS *

VERTICAL—1∅

RECTANGULAR—1∅

U2864-X-PED-KK(Order breakers and pedestal

raceway as extra)

U2866-X(Shown without pedestal)

CECHAAPPROVED

*CONNECTORS: For line wire connector kits, order separately.FIFTH TERMINALS: For field mounted fifth terminal order cata-

log number K2381. Order one per meter position (9 oʼclockposition only).

BREAKERS: Units have provision for one double pole main permeter position. Breakers not included, order as extra.

UNDERGROUND SERVICE: For underground service orderS2291-TO pedestal raceway. Order separately.

PEDESTAL EXTENSION KIT: A 12” pedestal extension kit isalso available. Order catalog number S2571.

PLUG-IN BREAKER COMPATIBILITY CHART

AMPS CUTLER-HAMMER(WESTINGHOUSE)

SIEMENS(ITE)

SIEMENSMURRAY /

CROUSE-HINDSG.E. SQ-D

125-200 HQP / BR / WBJ — MD THQ —

≤ 100 QP / BR / HQP QP MP THQ HOMELINE

Page 17: Meter Mounting Equipment Commonwealth Edison

17C

ON

DO

MIN

IUM

METER

ING

BA

NK

S–RIN

GLESS–O

H/U

G SER

VIC

E–1∅3W

–120/240 VA

CCONDOMINIUM METERING BANKS–RINGLESS–OH/UG SERVICE–1∅3W–120/240 VAC

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

17

29" or 41"

4-7/8"

25" or 37"

21"

E

A

18"

A A 4-7/8"

D D

E E

PED

PED

C

AA

25" or 37"

4-7/8"

31"

PED A AA A

C

29" or 41"

4-7/8"

36"

PEDE E E E EE

VERTICALwith pedestal option in bottom

RECTANGULARwith pedestal option in bottom

125 amp/pos.(2-3 position)

200 amp/pos.(2-3 position)

125 amp/pos.(4,5 & 6 position)

200 amp/pos.(4,5 & 6 position)

FIG.

A

B

C

D

E

DIMENSIONS

11⁄4 ″ CONCENTRIC K.O.

1⁄4,1⁄2″ CONCENTRIC K.O.

3″ CONCENTRIC K.O.

4″ HUB OPENING

2″ CONCENTRIC K.O.

PEDESTAL OPTIONPedestal Raceway

S2291-TO

PEDESTAL OPTIONPedestal Extension Unit

S2571

CECHAAPPROVED

CONDOMINIUM METERING BANKS

FIFTH TERMINAL # K2381(125-200 amp)

U2852-X

Page 18: Meter Mounting Equipment Commonwealth Edison

100 / 200 AMP–4 TERMINAL–RESIDENTIAL PEDESTALSINGLE OR DOUBLE POSITION–1∅3W–600 VAC18

100

/ 20

0 A

MP–

4 TE

RM

INA

L–R

ESID

ENTI

AL

PED

ESTA

L–SI

NG

LE O

R D

OU

BLE

PO

SITI

ON

–1∅

3W–6

00 V

AC

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

18

Extension UnitK5800

U8436-O

HANGING HOOK: Supplied with keyhole hanger for easy mounting.EXTENSION UNIT: For 24” burial applications, order extension unit S8988 for U8303-O. For 15” burial applications, order exten-

sion unit K5800 for U8436; for 30” applications, order (2) K5800 units.FIFTH TERMINAL: For field installed fifth terminal on U8436, order catalog number K5T (9 oʼclock position). For field installed

fifth terminal on U8303-O, order catalog number 5T8K2 (9 oʼclock position).BYPASS: Horn type bypass used on both units.BLOCK ASSEMBLY: For block assembly information for the U8436, see accessory section.

AMP

200

SERVICE CATALOGNUMBER

HUB

UG U8436-O BLANK

CONNECTORSCU/AL

LINE(COMPRESSION) LOAD

BY-PASS

HORN

DIMENSIONS CONCENTRIC K.O.ʼS

1 2 3 4 5

2 2 5⁄161⁄2 2

D″ W″ H″

41⁄8 9 624/0 (Line)2/0 (Neutral) #6-350 kcmil

6

200 2 POS-UG U8303-O BLANK HORN 11⁄4 5⁄16 21⁄2 21⁄2 21⁄241⁄2 83⁄16 744/0 (Line)2/0 (Neutral) #6-350 kcmil 1⁄4,

1⁄2

100 / 200 AMP—4 TERMINAL—CECHA APPROVED—RINGLESS—1∅3W—600 VAC

18"

Grade Line

3

Grade Line

CHECHAMILBANK

6

6

221

CHECHA

52

3

24 4

U8303-O

Extension UnitS8988

CECHAAPPROVED

GRADE LINE

1

2

2

5

32

3

4

18.00

Page 19: Meter Mounting Equipment Commonwealth Edison

19100 / 200 A

MP–1∅

–120 / 240 VA

C–4 TER

MIN

AL–M

ETER M

AIN

PEDESTA

L100 / 200 AMP–1∅–120 / 240 VAC–4 TERMINAL–METER MAIN PEDESTAL

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

100 / 200 AMP—1∅3W—RINGLESS–UNDERGROUND FEED

HUBCONNECTOR

CU/AL

LINE LOAD

BLANK #6-350KCMIL CB *

CATALOG NUMBER

NU8980-O-KK

NU8980-O-KK-LP BLANK #6-350KCMIL CB *

BLANK #6-350KCMIL #6-1/0NU8980-O-SF100-KK

NU8980-O-SF100-KK-LP

NU8980-O-200-KK

NU8980-O-200-KK-LP

22K10K

MAIN BREAKER

——

— —

UQFPHUQFP

Q2100HQ2100

UQFPHUQFP

UQFPHUQFP

BLANK

BLANK

BLANK

DIMENSIONS CONCENTRIC K.O.ʼS

1 2 3D″ W″ H″

21⁄2 21⁄2 —6 9 79

21⁄2 21⁄2 —6 9 70

21⁄2 21⁄2 —6 9 79

21⁄2

21⁄2

21⁄2

21⁄2

21⁄2

21⁄2

6

6

6

9

9

9

70

79

70

#6-350KCMIL

#6-350KCMIL

#6-350KCMIL

#6-1/0

1/0-300

1/0-300

MILBANK

1

2

Grade Line

STD = 79"-LP = 70"

STD = 36"-LP = 24"

* FIELD INSTALLED CIRCUIT BREAKER REQUIRED.MAIN CIRCUIT BREAKERS: For 10K AIC order with factory installed main. For 22K AIC order pedestal without main and order

circuit breaker separately. All main breakers are parallel connected. For series wired main order wire kit # K4714 and UQFP-Mtype circuit breaker. See Milbank circuit breaker chart on accessory page.

BRANCH CIRCUIT BREAKERS: Branch Interior accepts most manufacturers small frame plug-in type circuit breakers (Milbank,GE, Siemens, Cutler-Hammer, Murray).

SF in catalog number has small frame plug-in type circuit breaker installed on middle stabs of 4 circuit interior. Only two single polespaces available.

FIFTH TERMINAL: For field installed 5th terminal order kit # 5T8K2. Mounts in 9 o'clock position only.BYPASS: All pedestals have horn-type bypass installed for meter testing or replacement without interrupting customer service.EXTENSION KIT: Available for low profile (-LP) units only. Order kit # K4694. See accessory page.

NU8980-O-KK

CECHAAPPROVED

BY-PASS

HORN

HORN

HORN

HORN

HORN

HORN

19

Page 20: Meter Mounting Equipment Commonwealth Edison

U5706 TEMP TO FINAL SERVICE PEDESTAL–RINGLESS20

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

20

SPECIFICATIONS• 200 amp, 1∅, 120/240 volt, 22K AIC, underground service only.• U5706 has Ringless meter socket available with or without horn bypass (-KK). • Suitable for use as service equipment, mobile home service equipment and temporary power

service equipment.*• Provisions for up to two Type 3R in-use receptacle kits. *• Order receptacle and bridge kits separately. See ordering information.• Direct burial pedestal suitable for free standing or structure mounted installation.• Separate line and load wireways are removable, lockable and sealable for security.• Left side is for utility connection. Right side is for customer underground load exit.• Convenient knockouts in post for thru-wall load exit requirements.• Type 3R enclosure constructed with type G90 galvanized steel. • Repaintable light gray polyester powder coat finish.• Wire terminations accept copper or aluminum conductors: Line & Neutral: #6-350 Ground: (4) #14-1/0.• Main circuit breaker can be series or parallel connected. • Universal 4 circuit branch 125 amp interior (up to (2) 2-pole) accepts most manufacturers plug-in type

circuit breakers. See wiring diagram.

U5706-O-200S*(Shown with (2) K5400-520GR receptacles,

K5400-BRIDGE-2POS & line side conduc-tor installed.)

8-1/2”

13-1/4”

19”

A

A

A

A

A

30-3/16”

E

Bridge Kit(4) .173” Extr. Holes

3-1/2”

B

C

D

OPEN

Concentric KnockoutsA (4) = 1, 1-1/2, 2, 2-1/2”

B (1) = 1-1/4, 1-1/2, 2”

C (1) = 3/4”, 1”

D (1) = 1/4”, 1/2”

E (1) = 1” Solid

U57

06 T

EMP

TO F

INA

L SE

RV

ICE

PED

ESTA

L–R

ING

LESS

Page 21: Meter Mounting Equipment Commonwealth Edison

21U5706 TEMP TO FINAL SERVICE PEDESTAL ORDERING INFORMATION

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

21

U5706 Ringless PedestalMain Main Replacement Branch Weight

Catalog Number Amps Service By-Pass Circuit Breaker Wired Main Type* Circuits LBS.

◆ U5706-O-200S-CECHA 200 120/240 None 200a 2p Series UQFPH-M 4 79

Up to two receptacle/circuit breaker kits can be field or factory installed. See below for ordering information. Contact factory for factory installed kits.

To increase pedestal height, order field-installed post extension kit K5708.For field installed fifth terminal in the 9 oʼclock position, order kit 5T9.For field converting from parallel to series wired, order kit K5194. For field converting from series to parallel wired, order kit K5193.

Receptacle / Circuit Breaker Kits & Receptacle Bridge Kits

Catalog Number Amps/ Volts NEMA Config Circuit Breaker Conductor Configuration

◆ K5400-520GR 20a 120v 5-20R Duplex GFI 20a 1p 12 awg Fig. 1

◆ K5400-620 20a 240v 6-20R Simplex 20a 2p 12 awg Fig. 2

◆ K5400-620GB 20a 240v 6-20R Simplex 20a 240v GFI 12 awg Fig. 3

◆ K5400-1450 50a 120/240v 14-50R 50a 120/240v 8 awg Fig. 4

◆ K5400-1450GB 50a 120/240v 14-50R 50a 120/240v GFI 8 awg Fig. 4

◆ K5400-BRIDGE-1POS Self-grounded ONE position bridge with hardware and instructions. Fig. 5

◆ K5400-BRIDGE-2POS Self-grounded TWO position bridge with hardware and instructions. Fig. 6

Receptacle kits include: receptacle, circuit breaker, connected wire, cover plate, mounting screws and instructions. Contact factory for other kits.

NOTE: Receptacle grounding is provided by metal contact with bridge and pedestal. Be sure to torque all fasteners per torque requirements.

◆ Stock item – availability subject to prior sale.

Non-stock items – minimum order quantity required.

Fig. 1 Fig. 2 Fig. 3 Fig. 4K5400-520GR K5400-620 K5400-620GB K5400-1450

Fig. 5 Fig. 6 Fig. 7K5400-BRIDGE-1POS K5400-BRIDGE-2POS UQFPH-M-200

U5706 TEM

P TO FIN

AL SER

VIC

E PEDESTA

L OR

DER

ING

INFO

RM

ATIO

N

Page 22: Meter Mounting Equipment Commonwealth Edison

320 AMP–4 TERMINAL–METER PEDESTAL WITH LEVER BYPASS2232

0 A

MP–

4 TE

RM

INA

L–M

ETER

PED

ESTA

L W

ITH

LEV

ER B

YPA

SS

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

22

CATALOGNUMBER

U3849-O-2/200

SERVICE

UG

HUB

NONE

CONNECTORSCU/AL

LINE LOAD3/8″ X 16STUDS

C.B. #1- 300kcmil

BY-PASS

LEVER

DIMENSIONS CONCENTRIC K.O.ʼS

1D″ W″ H″

21⁄247⁄8 13 58

2

21⁄2

3

5⁄16

4

5

320 AMP–4 TERMINAL—METER MAIN WITH BREAKERS—RINGLESS—240 VAC

CATALOGNUMBER

U1748-O

SERVICE

UG

HUB

NONE

CONNECTORSCU/AL

LINE LOAD3/8″ X 16STUDS

TWIN#6-350 kcmil

BY-PASS

LEVER

DIMENSIONS CONCENTRIC K.O.ʼS

1D″ W″ H″

21⁄247⁄8 13 64

2

21⁄2

3

21⁄2

4

5⁄16

5

320 AMP–4 TERMINAL—WITHOUT BREAKER—RINGLESS—600 VAC

CONNECTORS: The line wire section is supplied with 3⁄8″–16 studs with hex head nuts and captive Belleville washers. Theline side connectors are to be supplied by the Utility, load side is furnished.

BYPASS: The lever supplies clamping action on the meter spade and also operates the bypass device.FIFTH TERMINAL: For field installed fifth terminal order kit #K3865.PEDESTAL EXTENSION KIT: If extension kit is required, order as extra kit # S1848. See accessory page.

BREAKERS: The U3849 is furnished with (2) 200 amp Milbank type UQFBH-200 circuit breakers.PEDESTAL EXTENSION KIT: If extension kit is required, order as extra kit # S1848. See accessory page.THIS UNIT IS RATED 22,000 AIC—SHORT CIRCUIT CURRENT RATING WITH MILBANK UQFBH SERIES CIRCUIT

BREAKER.

U3849-O-2/200U1748-O

Grade Line

1 2

3

M I L B A N K

3

3 3

Grade Line

18"

Grade Line

1

2 3

1

2

4 4

4 4

Grade Line

18"

320 AMP CONTINUOUS400 AMP MAX

4-27/32"I.D.13"

O.D.

16-15/16"15"

S1848Pedestal Extension Unit

CECHAAPPROVED

Page 23: Meter Mounting Equipment Commonwealth Edison

23100 / 200 A

MP–5 &

7 TERM

INA

L–LEVER

BY

PASS–H

EAV

Y D

UTY

PEDESTA

L–600 VA

C100 / 200 AMP–5 & 7 TERMINAL–LEVER BYPASS–HEAVY DUTY PEDESTAL–600 VAC

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

23

1 2 3

44

MILBANK

4 4

4 4

CATALOGNUMBER

U9108-O

SERVICE

UG

HUB

BLANK

CONNECTORSCU/AL

LINE LOAD

3/0-4/0 #6-350kcmil

BY-PASS

LEVER

DIMENSIONS CONCENTRIC K.O.ʼS

1D″ W″ H″

21⁄26 11 58

2

21⁄2

3

21⁄2

4

5⁄16

5

#OF

TERMS

5

100 / 200 AMP—5 TERMINAL—HEAVY DUTY—1∅-3W OR 3∅-3W

CATALOGNUMBER

U9107-O

SERVICE

UG

HUB

BLANK

CONNECTORSCU/AL

LINE LOAD

3/0-4/0 #6-350kcmil

BY-PASS

LEVER

DIMENSIONS CONCENTRIC K.O.ʼS

1D″ W″ H″

21⁄26 11 58

2

21⁄2

3

21⁄2

4

5⁄16

5

#OF

TERMS

7

100 / 200 AMP—7 TERMINAL—HEAVY DUTY—3∅4W

BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.BOTTOM PLATE: Bottom plate is not furnished with this unit. However, plates are required on all installations within the

city of Chicago. Order catalog number S9157 as extra.NEUTRAL: The U9108-O is supplied with a center disconnect neutral. EXTENSION KIT: For direct burial applications, order kit S3488 as separate item.

U9107-O

91089107

PEDESTAL EXTENSION UNITS3488

CECHAAPPROVED

Page 24: Meter Mounting Equipment Commonwealth Edison

JOINT USE TERMINATION CABINET24JO

INT

USE

TER

MIN

ATI

ON

CA

BIN

ET

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

24

Grade Line

12"

58"

13" 13"

37 5/16" 33 5/16" 39"

1

3

21"2

4 6"

JOINT USE TERMINATION CABINET

CATALOGNUMBER HUB

CONNECTOR CU/AL BY-

PASS

DIMENSIONS CONCENTRIC K.O.ʼS

1 2 3 4D″ W″ H″LINE LOAD

U4329-O BLANK NONE (6)1″ (1)1⁄2″ (1)1″ (2)7⁄16″41⁄2 13 58NONE NONE

COMMUNICATION COMPARTMENT: Easily attaches to Milbank meter pedestals for use in newconstruction.

TELEPHONE AND CABLE CONDUCTORS: This unit will accommodate both telephone and cable con-ductors, eliminating the use of multiple, unsightly network interface devices on the outer structure of thehome, while providing tamper resistance to the communication modules.

SINGLE LOCATION POINT OF SERVICE: The S4329 combined with the Milbank meter pedestalprovides a single location point of service making access for utility service personnel convenient andefficient.

APPROVED: The U4329 is approved by COMMONWEALTH EDISON COMPANY and all majorWISCONSIN UTILITIES.

U4329

CECHAAPPROVED

Page 25: Meter Mounting Equipment Commonwealth Edison

2520 A

MP–6, 8 &

13 TERM

INA

L–INSTR

UM

ENT TR

AN

SFOR

MER

RA

TED SO

CK

ET20 AMP–6, 8 & 13 TERMINAL–INSTRUMENT TRANSFORMER RATED SOCKET

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

25

1

3 4 56

2

# OFTERMS

6

PHASE CATALOGNUMBER

1∅3W CE136

SERVICEDIMENSIONS CONCENTRIC K.O.ʼS

1 2 3 4 5

11⁄4 11⁄4 11⁄4 11⁄4 11⁄4

6

1⁄4,1⁄2

D″ W″ H″

41⁄8 12 20Bottom Feed

8 3∅3W CE138 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 1⁄4,1⁄241⁄8 12 20Bottom Feed

13 3∅4W CE1313 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 1⁄4,1⁄241⁄8 12 20Bottom Feed

20AMP—6, 8 & 13 TERMINAL—TRANSFORMER RATED SOCKET

CE1313CE136

CECHAAPPROVED

• Type 3R enclosure• One-piece sealable cover, padlock provision• Approved by COMMONWEALTH EDISON COMPANY and all major WISCONSIN UTILITIES.

Page 26: Meter Mounting Equipment Commonwealth Edison

COMMERCIAL METER PEDESTALS OVERVIEW26C

OM

MER

CIA

L M

ETER

PED

ESTA

LS O

VER

VIE

W

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

26

ilbank Commercial Pedestals are pad-mounted, weatherproof electricalenclosures consisting of a utility pull section with optional meter socket, anda customer section containing distribution and control equipment. Milbank

Commercial Pedestalsare an attractive, secure,easy to install and cost-effective solution whenunderground remotesite power distributionand control equipmentis required, replacingunsightly and inefficientstrut and backboardstructures.

Un-Strut

Your

Stuff...

Commercial Pedestals • Attractive • Easy to install • Secure • Cost effective

STANDARD FEATURES –COMMERCIAL PEDESTALS

• Type 3R rainproof, vandal-resistant cabinet ofpolyurethane powder-coated steel (aluminum orstainless steel also available)

• UL listed as enclosed industrial control equip-ment (UL508)

• Isolated, lockable & sealable utility metering &lug landing sections

• Lockable customer section for distribution &control equipment with internal deadfront

• Print pocket inside customer section doorcontains wiring schematicsand installation instructions

• Most load centers are UL listed for use with variousmanufacturers’ circuit breakers

• All stainless steel externalhardware (screws, bolts,hinges, handles, hasps andsealing screws)

• Meets EUSERC 308 and otherutility standards.

Ringless Socket Ring-type Socket

Utility Lug Landing Customer Interior

UL Listed as Industrial Control Equipment (File E113855).

Strut and backboard design Commercial Pedestal

Page 27: Meter Mounting Equipment Commonwealth Edison

27APPLICATIONS & ACCESSORIES

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

27

CP-16PDMNT-CALTPedestal mounting base for 16" pedestal CP-24PDMNT-CALTPedestal mounting base for 24" pedestal (includes mounting hardware)CP-32PDMNTPedestal mounting base for 32" pedestal (includes mounting hardware)

CP-ABK5/8Anchor bolt kit (includes four 5/8 -13 x 18" anchor bolts) CP-PE-HOA-3POS

HOA switch – for fieldinstallation

ACCESSORIES

CP-TC7D 7-day time clock kit

CP-TC24H 24-hour time clock kit

CP-TCWIRE Male four-pin connector and wiring harness for use with time clocks other than shown

K3865Fifth terminal kit foruse with ringlessmeter sockets

• Meter sockets – ring type or ringless, to 400 amp (unmeteredand dual-metered pedestals also available)

• Main and branch breakers or T fuses• Distribution – copper load centers & panel boards • Clocks / timers / relays• Photoelectric cells and controls• Power receptacles – pin & sleeve, twist lock or straight blade • Contactors – definite purpose, electrical or mechanically

held, IEC and mercury types• Surge protection & lightning arrestors• Reserve inlet generator receptacle with interlocked circuit

breakers

• Motor starters, relays • Push button controls• Thermostat controls, fans and heating strips• Power blocks and terminal blocks• Steel, aluminum and plywood back boards• Transformers• Interlock devices for circuit breakers• Available in steel, aluminum (raw painted or anodized) or

stainless steel construction with powder-coated finish avail-able in 8 standard colors or special ordered RAL colors.

• Available for applications up to 400 amp, 120V, 208V,240V, 277V, 480V – 1Ø or 3Ø.

APPLICATIONSThese units are ideal for controlling and metering:• Traffic signals• Street lighting• Irrigation / sprinkler systems• Cell towers / telephone vaults• Pump stations• Temporary power for fairgrounds, swap meets, outdoor

markets, portable offices, holiday lights, etc.• Outdoor lighting for athletic fields, tennis and basketball courts, parking lots, land-

scaping and subdivision entrances, etc.

AVAILABLE FACTORY-INSTALLED OPTIONS

105JFifth terminalkit for usewith ring-typemeter sockets

CP-16FPADFiberglass pedestal mounting basefor 16" pedestal (direct buried)

APPLIC

ATIO

NS &

AC

CESSO

RIES

Page 28: Meter Mounting Equipment Commonwealth Edison

DISCONNECT SLEEVE*

M5-144

ACCESSORIES28A

CC

ESSO

RIE

S

4 1⁄2 8 3⁄16 15S8988

CATALOGNUMBER

D″ W″ H″

S3488S2571S1848

6 11 15

4 1⁄8

4 7⁄8

10

13

12

15

K4694K5800

6

4 1⁄89

9

24

15

INTERCHANGEABLE UNIT HUBS

CLOSING COVERS

METAL CLOSING PLATE(for ringless sockets)

CP-21

METER CLOSING PLATE(Gray Plastic)

6003

HUBADAPTER PLATE

(Converts 4″ opening to21⁄2″ opening.)

S8324

FIFTH TERMINALS

100-200 amp “PLUG-IN” FIFTH TERMINAL

5T8K2

200 ampFIFTH TERMINAL

K5T(New style block with square hole)

HEAVY DUTY JAWCLAMPING

K3865

FOR CONDO METERING BANKS

(125-200 amp) K2381

PEDESTAL EXTENSION UNITS

HUB SUFFIX CHART

O Plain Top WL 1″ For -RL OpeningYL 11⁄4″ For -RL OpeningZL 11⁄2″ For -RL OpeningDL 2″ For -RL OpeningELF

G

H

21⁄2″ For -RL Opening

3″ For -R Opening

31⁄2″ For -R Opening

4″ For -R Opening

RL Small Hub OpeningR Large Hub OpeningXL Small Closing PlateX

RXL Large Hub Openingadapted to small Closing Plate

RRL Large Hub Openingadapted to small Hub Opening

Large Closing Plate

REMOVABLE HUBCLOSING PLATE

DESCRIPTION SUFFIX CAT. #

-XL A7551

LARGE(for -R opening)

-X A9064

1″WL

SIZESUFFIX MILBANKNO.

YLZLDLEL

A751411⁄4″ A751511⁄2″ A75162″ A7517

21⁄2″ A7518

3″F

SIZESUFFIX MILBANKNO.

GH

A811031⁄2″ A81114″ A8112

SMALL “RL"OPENING(STANDARD)

LARGE “R” OPENING(HEAVY DUTY)

STANDARD(for -RL opening)

*NOT TO BE USED WITH LEVERBYPASS SOCKETS

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

28

Page 29: Meter Mounting Equipment Commonwealth Edison

29ACCESSORIES

29

PLUG-IN BREAKER COMPATIBILITY CHART

AMPS MILBANK CUTLER-HAMMER(WESTINGHOUSE)

SIEMENS(ITE)

SIEMENSMURRAY /

CROUSE-HINDSG.E. SQ-D

125-200 Q / QN HQP / BR / WBJ Q / QN MD THQ —

≤ 100 Q QP / BR / HQP QP MP THQ HOMELINE

MILBANK2-POLE—LARGE FRAME—10K AIC & 22K AIC

AMPS

100 UQFP-100

125 UQFP-125

150 UQFP-150

175 UQFP-175

200 UQFP-200

10,000 AICPLUG-IN

UQFPH-100

UQFPH-125

UQFPH-150

UQFPH-175

UQFPH-200

UQFB-100

UQFB-125

UQFP-150

UQFB-175

UQFB-200

10,000 AICBOLT-ON

22,000 AICPLUG-IN

UQFP-M-100

UQFP-M-125

UQFP-M-150

UQFP-M-175

UQFP-M-200

10,000 AICPLUG-IN

UQFPH-M-100

UQFPH-M-125

UQFPH-M-150

UQFPH-M-175

UQFPH-M-200

22,000 AICPLUG-IN

UQFB-100-X1

UQFB-125-X1

UQFP-150-X1

UQFB-175-X1

UQFB-200-X1

10,000 AICBOLT-ON

UQFBH-100

UQFBH-125

UQFBH-150

UQFBH-175

UQFBH-200

22,000 AICBOLT-ON

BLOCK ASSEMBLIESCONNECTOR KITS

For use with 3/8”-16stud type units only

SINGLETWIN

K1350K2 6-350 kcmil

K1350L

K1541

K2L

K4

6-350 kcmil Non-rotating

4-600 kcmil

CATALOG #SUFFIX (3 per set) – 1 ∅

K3442K6 6-350 kcmil K3083K8 4-600 kcmil

CATALOG #SUFFIX (4 per set) – 3 ∅

K3082K5 6-350 kcmil

K3441K74-600 kcmil or

(2) 1/0-250 kcmil

CATALOG #SUFFIX (4 per set) – 3 ∅

K1539K1 6-350 kcmil

K1540

K1540L

K3

K3L

4-600 kcmil or(2) 1/0-250 kcmil

4-600 kcmil or(2) 1/0-250 kcmil

Non-rotating

CATALOG #SUFFIX (3 per set) – 1 ∅

Replaces the load side slide-in nut assembly onMilbank 200 amp sockets. Allows for a 100 amp taplocation in addition to the #6-350 kcmil load-sideconnector. K5022 Includes Safety BarrierExtensions–for applications over 300 VAC.

K4977-INT INTERNAL HEX

K5022-INT INTERNAL HEX

PERFECT FOR 100 AMP FEEDS TO:• Outdoor Lighting• Water Well Pumps• Hot Tubs and Swimming Pools• Outbuildings• Whole House Surge Suppressors

LOAD TAP CONNECTORS (3 per set)

STD.BLOCKASSEMBLY(200 amp)

K4529

LEFT & RIGHT BLOCKASSEMBLY FOR U8436

(200 amp) Z917525-AC Left

Z917526-AC Right

Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.

AC

CESSO

RIES

Page 30: Meter Mounting Equipment Commonwealth Edison

CONDUIT AND AMPACITY INFORMATION30C

ON

DU

IT A

ND

AM

PAC

ITY

IN

FOR

MA

TIO

N

30

TYPE

RHW & RHH(without outer covering)

THW

CONDUCTORSIZE

AWG,MCM1412108

CONDUIT TRADE SIZES (INCHES)1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 46441

10863

1613115

29241910

40322613

65534322

93766132

1431179549

19215712766

16385

6 1 2 3 7 10 16 23 36 48 62

3 1 1 2 4 6 10 15 23 31 40

1/02/03/04/0

250300350400500

600700750

111

1111

2111

3321

5543

8765

121097

16141210

21181513

11

11111

11111

22111

43321

65443

87654

109876

111

111

111

322

433

544

TWTHW

FEPB (6 thru 2),RHW and

RHH(without outer covering)

RH, THHW

*This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C.

*CU

A

18161412108

64321

1/02/03/04/0

250300350400500

600700750

255285310335380

420460475

——

20✝25✝35✝50

6585100115130

150175200230

B

250300350400500

600700750

———12108

64321

1/02/03/04/0

A

AL or Cu-Clad AL

205230250270310

340375385

———

20✝30✝40

50657590100

120135155180

C

AMBIENTTEMP.C°

CORRECTIONFACTOR

AMBIENTTEMP.F°

21 - 25 1.05 70 - 7726 - 30 1.00 79 - 8631 - 35 .94 88 - 9536 - 40 .88 97 - 10441 - 45 .82 106 - 11346 - 50 .75 115 - 12251 - 55 .67 124 - 13156 - 60 .58 133 - 14061 - 65 .33 142 - 15866 - 70 — 160 - 176

* ALLOWABLE AMPACITIES OF INSULATED COPPER &ALUMINUM CONDUCTORS (3W IN CONDUIT) 75°C (167°F)

AMPACITY CORRECTION FACTORS

Overall ampere ratings of UL Listed Milbank multiple position meter sockets are based on 1993N.E.C. Manual article 220-32 and ANSI / UL-414 (except where restricted by line connector size).These requirements provide for a diversity factor / demand factor being utilized in determining the over-all (main bus / lug) rating of a gang socket. All Milbank UL Listed gang sockets meet or exceed thesediversity factor/demand factor requirements. Standard overall ampacity ratings for UL Listed and nonUL Listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are basedon the meter socket being wired with 75° C insulated wire conductor, sized in accordance with Table310-16 of the National Electric Code.

NO. OF METERPOSITIONS

100A / POS.AMPACITY

125A / POS.AMPACITY

150A / POS.AMPACITY

200A / POS.AMPACITY

23456

200A200A200A225A270A

200A225A250A285A330A

200A225A270A338A396A

200A270A360A450A528A

MAXIMUM NUMBER OF CONDUCTORS IN CONDUIT*

A = Size: AWG/MCMB = Ampere Rating forInsulation Types:

FEPW, RH, RHW,THW, THWN, XHHW,

USE, 2W.C = Ampere Rating forInsulation Types:

RH, RHW, THW,THWN, XHHW, USE

(Per NEC table 310-16)

✝ Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk (✝) shall not exceed 15amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG copper: or 15 amps for 12 AWG and 25 amps for 10 AWG aluminum andcopper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied.

All meter sockets are 600 Volt rated unless otherwise noted.All meter socket ampacity ratings are continuous duty unless otherwise noted.

GANG SOCKET OVERALL AMPACITIES

Page 31: Meter Mounting Equipment Commonwealth Edison

31ENERGIZATION OF ELECTRICAL EQUIPMENT

31

ENER

GIZ

ATIO

N O

F ELECTR

ICA

L EQU

IPMEN

T

BEFORE ENERGIZING

IMPORTANT NOTE

WHEN ENERGIZING

AFTER ENERGIZING

A. Give equipment a thorough visual examination to determine that:1) No shipping or installation damage exists.2) Proper clearances have been maintained.3) All connections have been made.4) Equipment is clean and dry.

B. Make a thorough examination to verify:1) Tightness of all bolted connections (see table below).2) Manually operate all circuit breakers, switches, relays, etc.3) Check rigidity of all mountings, bus bars and components.4) Use test equipment to check continuity of circuitry and integrity of insulation.

C. All switches and circuit breakers should be in the “off” position.D. Verify that manual meter bypass (if applicable) is in non-bypass position.E. Install cover and/or close doors.F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These

steps will secure the installation in case of accidental energization.

A. Use caution and follow established safety procedures:1) Wear safety apparel.2) Use safety equipment.3) Take action to prevent injury to yourself and others in the event of failure of the installation.4) Take action to prevent/decrease damage to property in the event of failure of the installation.5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it.

A. Secure the installation:1) To prevent accidental contact with energized parts, cover all openings with approved filler devices.2) To prevent unauthorized access, secure all covers and/or doors with approved security devices.3) Attach/post information to advise others of potential hazards associated with the installation.

NOMINALSIZE

10

10

10

12

12

1/4

1/4

5/16

JOINT DESCRIPTION

SCREW NUTBRASS

STEEL

STEEL

STEEL

STEEL

STEEL

STEEL

STEEL

Brass Nut or Extruded Hole

CU or AL Busbar <1/8″Steel Nut or EH; CU or AL Busbar >1/8″

Aluminum Extruded Hole

Steel Nut or Extruded Hole

Aluminum Extruded Hole

Steel Nut or EH; CU or AL Busbar

Aluminum Extruded Hole

ALL

ALL

ALL

ALL

ALL

ALL

ALL

HEX

20-25 in. lbs.

25-30 in. lbs

30-35 in. lbs

30-35 in. lbs

40-50 in. lbs.

40-50 in. lbs.

50-60 in. lbs.

60-70 in. lbs.

5/16 STEEL Steel Nut or EH; CU or AL Busbar HEX 100-150 in. lbs.

3/8 STEEL Steel Nut HEX 150-200 in. lbs.

1/2 STEEL Steel Nut HEX 200-250 in. lbs.

HEAD TYPE TORQUE( INCH LBS. )

*Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first.EH: Extruded HoleCU: CopperAL: Aluminum

RECOMMENDED TORQUE FOR GENERAL APPLICATIONS*

In addition to national and local electrical codes, many utilities have specific requirements for metering equip-ment. Always consult the serving utility for their specifications and requirements prior to ordering or installingMilbank meter mounting equipment.

Page 32: Meter Mounting Equipment Commonwealth Edison

MATERIALS AND FINISHES32M

ATE

RIA

LS A

ND

FIN

ISH

ES

32

MATERIALS

STEEL SHEET

STEEL QUALITY

ALUMINUM EXTRUSION

ALUMINUM SHEET

COPPER SHEET & BUS

INSULATING MATERIALS

PROCESS

METAL FASTENERS

The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford thebest possible weather proofing. *American Iron and Steel Institute.

Light gray “state of the art” electrostatically applied powder paint offers a durable, non-fadingfinish. For further information concerning the chemical analysis of the weather resistant finish,please contact the factory.

Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire.Bus Bar: Alloy; 6101-o & 6063-O

3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thick-nesses range from .064 — .125

Electrolytic copper with tin plating in most applications.

Zinc-coated with a chromate dip.

• In most units, support bases for current-carrying components are molded from fiberglass rein-forced high-strength, track resistant, thermoset polyester molding compounds.

• Clear or black safety shields and polarity barriers are molded from high-strength, track resistant,polycarbonate molding compounds.

• Various sheet insulating materials, as appropriate for the application are utilized in the fabrica-tion of flat, formed and punched component parts and barriers.

16 gauge, galvanized, sheet: 0.90 oz./ sq.ft. class zinc-coated.(AISI G90)14 gauge, galvanized, sheet: 0.90 oz./ sq.ft. class zinc-coated.

FINISH

NEMA RATING

All Milbank meter sockets, CT cans and meter socket / breaker units have a NEMA 3R rating.

RATING

Page 33: Meter Mounting Equipment Commonwealth Edison

33ADDITIONAL MILBANK PRODUCTS

33

COMMERCIAL / INDUSTRIALELECTRICAL ENCLOSURES

2008 PRICE LISTEffective June 2, 2008

Supercedes and cancels all previous Milbank lists.All prices listed within are subject to change without notice.

MILBANK MFG. CO.

Kansas City, MO 64141-6028Tel: 816.483.5314

www.milbankmfg.com

In addition to your local utility’s meter mountingequipment, Milbank also manufactures

supporting products, such as...

Air Conditioner DisconnectsHot Tub Disconnects

RV/Mobile Home Power OutletsTerminal Boxes

Temporary Power OutletsCommercial PedestalsCommercial Enclosures

CT EnclosuresCircuit Breakers

Distribution Unit SubstationsEnclosed Circuit Breakers

Safety SwitchesTest Switches

Contact your local distributor or go towww.milbankmfg.com

to find additional product literature.

Other quality products available from Milbank

AD

DITIO

NA

L MILB

AN

K PR

OD

UC

TS

Page 34: Meter Mounting Equipment Commonwealth Edison

INDEX34IN

DEX

34

105J . . . . . . . . . . . . . . . . . . . . . . . . . 27

6003 . . . . . . . . . . . . . . . . . . . . . . . . . 28

5T8K2 . . . . . . . . . . . . . . . . . . . . . . . 28

A7514 . . . . . . . . . . . . . . . . . . . . . . . . 28

A7515 . . . . . . . . . . . . . . . . . . . . . . . . 28

A7516 . . . . . . . . . . . . . . . . . . . . . . . . 28

A7517 . . . . . . . . . . . . . . . . . . . . . . . . 28

A7518 . . . . . . . . . . . . . . . . . . . . . . . . 28

A7551 . . . . . . . . . . . . . . . . . . . . . . . . 28

A8110 . . . . . . . . . . . . . . . . . . . . . . . . 28

A8111 . . . . . . . . . . . . . . . . . . . . . . . . 28

A8112 . . . . . . . . . . . . . . . . . . . . . . . . 28

A9064 . . . . . . . . . . . . . . . . . . . . . . . . 28

CE1313 . . . . . . . . . . . . . . . . . . . . . . 25

CE136 . . . . . . . . . . . . . . . . . . . . . . . 25

CE138 . . . . . . . . . . . . . . . . . . . . . . . 25

CP-16FPAD . . . . . . . . . . . . . . . . . . . 27

CP-16PDMNT-CALT . . . . . . . . . . . . 27

CP-21 . . . . . . . . . . . . . . . . . . . . . . . . 28

CP-24PDMNT-CALT . . . . . . . . . . . . 27

CP-32PDMNT . . . . . . . . . . . . . . . . . 27

CP-ABK5/8 . . . . . . . . . . . . . . . . . . . . 27

CP-PE-HOA-3POS . . . . . . . . . . . . . 27

CP-TC24H . . . . . . . . . . . . . . . . . . . . 28

CP-TC7D . . . . . . . . . . . . . . . . . . . . . 28

CP-TCWIRE . . . . . . . . . . . . . . . . . . . 28

K1350 . . . . . . . . . . . . . . . . . . . . . 16, 29

K1350L . . . . . . . . . . . . . . . . . . . . . . . 29

K1539 . . . . . . . . . . . . . . . . . . . . . 16, 29

K1540 . . . . . . . . . . . . . . . . . . . . . 16, 29

K1540L . . . . . . . . . . . . . . . . . . . . . . . 29

K1541 . . . . . . . . . . . . . . . . . . . . . 16, 29

K2381 . . . . . . . . . . . . . . . . . . . . . . . . 28

K3082 . . . . . . . . . . . . . . . . . . . . . . . . 29

K3083 . . . . . . . . . . . . . . . . . . . . . . . . 29

K3441 . . . . . . . . . . . . . . . . . . . . . . . . 29

K3442 . . . . . . . . . . . . . . . . . . . . . . . . 29

K3865 . . . . . . . . . . . . . . . . . . . . . . . . 28

K4529 . . . . . . . . . . . . . . . . . . . . . . . . 29

K4694 . . . . . . . . . . . . . . . . . . . . . . . . 28

K4977-INT . . . . . . . . . . . . . . . . . . . . 29

K5022-INT . . . . . . . . . . . . . . . . . . . . 29

K5800 . . . . . . . . . . . . . . . . . . . . . . . . 28

K5T . . . . . . . . . . . . . . . . . . . . . . . . . 28

L572-XL-KK . . . . . . . . . . . . . . . . . . . 14

L573-XL-KK . . . . . . . . . . . . . . . . . . . 14

L574-XL-KK . . . . . . . . . . . . . . . . . . . 14

L575-XL-KK . . . . . . . . . . . . . . . . . . . 14

L576-XL-KK . . . . . . . . . . . . . . . . . . . 14

M5-144 . . . . . . . . . . . . . . . . . . . . . . . 28

NU8980-O-200-KK . . . . . . . . . . . . . . 19

NU8980-O-200-KK-LP . . . . . . . . . . . 19

NU8980-O-KK . . . . . . . . . . . . . . . . . 19

NU8980-O-KK-LP . . . . . . . . . . . . . . 19

NU8980-O-SF100-KK . . . . . . . . . . . 19

NU8980-O-SF100-KK-LP . . . . . . . . 19

Q2100 . . . . . . . . . . . . . . . . . . . . . . . 19

Q2100H . . . . . . . . . . . . . . . . . . . . . . 19

S1848 . . . . . . . . . . . . . . . . . . . . . . . . 28

S2571 . . . . . . . . . . . . . . . . . . . . . . . . 28

S3488 . . . . . . . . . . . . . . . . . . . . . . . . 28

S8324 . . . . . . . . . . . . . . . . . . . . . . . . 28

S8988 . . . . . . . . . . . . . . . . . . . . . . . . 28

U1252-X-KK-K1-PED . . . . . . . . . . . . 14

U1253-X-KK-K3-PED . . . . . . . . . . . . 14

U1254-X-KK-K3-PED . . . . . . . . . . . . 14

U1255-X-KK-K4-PED . . . . . . . . . . . . 14

U1256-X-KK-PED . . . . . . . . . . . . . . 14

U1748-O . . . . . . . . . . . . . . . . . . . . . 22

U2732-XT-PED . . . . . . . . . . . . . . . . 15

U2733-XT-PED . . . . . . . . . . . . . . . . 15

U2734-XT-PED . . . . . . . . . . . . . . . . 15

U2735-XT-PED . . . . . . . . . . . . . . . . 15

U2736-XT-PED . . . . . . . . . . . . . . . . 15

U2852-X-KK-K1-PED . . . . . . . . . . . . 16

U2853-X-KK-K1-PED . . . . . . . . . . . . 16

U2854-X-KK-PED . . . . . . . . . . . . . . 16

U2855-X-KK-PED . . . . . . . . . . . . . . 16

U2856-X-KK-PED . . . . . . . . . . . . . . 16

U2862-X-KK-K1-PED . . . . . . . . . . . . 16

U2863-X-KK-K1-PED . . . . . . . . . . . . 16

U2864-X-KK-PED . . . . . . . . . . . . . . 16

U2865-X-KK-PED . . . . . . . . . . . . . . 16

U2866-X-KK-PED . . . . . . . . . . . . . . 16

U3800 . . . . . . . . . . . . . . . . . . . . . . . . 5

U3801 . . . . . . . . . . . . . . . . . . . . . . . . 5

U3830 . . . . . . . . . . . . . . . . . . . . . . . . 5

U3860 . . . . . . . . . . . . . . . . . . . . . . . . 5

U3822-20GR . . . . . . . . . . . . . . . . . . . 6

U3849-O-2/200 . . . . . . . . . . . . . . . . 22

U4329-O . . . . . . . . . . . . . . . . . . . . . 24

U4363-X-QG-CECHA . . . . . . . . . . . . 8

U4881-O . . . . . . . . . . . . . . . . . . . . . . 6

U4881-O-50GB . . . . . . . . . . . . . . . . . 6

U4881-O-60GB . . . . . . . . . . . . . . . . . 6

U5168-XTL-100-KK-CECHA . . . . . . 11

U5168-XTL-150-KK-CECHA . . . . . . 11

U5168-XTL-200-KK-CECHA . . . . . . 11

U5706-O-200S-CECHA . . . . . . . 20-21

U5750-RXL-200-BL-CECHA . . . . . . 10

U5842-RL-KK . . . . . . . . . . . . . . . . . . 10

U7375-RL-KK . . . . . . . . . . . . . . . . . . . 9

U7607-RL-200-KK . . . . . . . . . . . . . . . 9

U8303-O . . . . . . . . . . . . . . . . . . . . . 18

U8436-O . . . . . . . . . . . . . . . . . . . . . 18

U8606-RXL . . . . . . . . . . . . . . . . . . . . 8

U8624-RXL . . . . . . . . . . . . . . . . . . . . 8

U8949-RL-TG-KK . . . . . . . . . . . . . . . 7

U9107-O . . . . . . . . . . . . . . . . . . . . . 23

U9108-O . . . . . . . . . . . . . . . . . . . . . 23

UQFB-100 . . . . . . . . . . . . . . . . . . . . 29

UQFB-100-X1 . . . . . . . . . . . . . . . . . 29

UQFB-125 . . . . . . . . . . . . . . . . . . . . 29

UQFB-125-X1 . . . . . . . . . . . . . . . . . 29

UQFB-150 . . . . . . . . . . . . . . . . . . . . 29

UQFB-150-X1 . . . . . . . . . . . . . . . . . 29

UQFB-175 . . . . . . . . . . . . . . . . . . . . 29

UQFB-175-X1 . . . . . . . . . . . . . . . . . 29

UQFB-200 . . . . . . . . . . . . . . . . . . . . 29

UQFB-200-X1 . . . . . . . . . . . . . . . . . 29

UQFBH-100 . . . . . . . . . . . . . . . . . . . 29

UQFBH-125 . . . . . . . . . . . . . . . . . . . 29

UQFBH-150 . . . . . . . . . . . . . . . . . . . 29

UQFBH-175 . . . . . . . . . . . . . . . . . . . 29

UQFBH-200 . . . . . . . . . . . . . . . . . . . 29

UQFP-100 . . . . . . . . . . . . . . . . . . . . 29

UQFP-125 . . . . . . . . . . . . . . . . . . . . 29

UQFP-150 . . . . . . . . . . . . . . . . . . . . 29

UQFP-175 . . . . . . . . . . . . . . . . . . . . 29

UQFP-200 . . . . . . . . . . . . . . . . . . . . 29

UQFPH-100 . . . . . . . . . . . . . . . . . . . 29

UQFPH-125 . . . . . . . . . . . . . . . . . . . 29

UQFPH-150 . . . . . . . . . . . . . . . . . . . 29

UQFPH-175 . . . . . . . . . . . . . . . . . . . 29

UQFPH-200 . . . . . . . . . . . . . . . . . . . 29

UQFPH-M-100 . . . . . . . . . . . . . . . . . 29

UQFPH-M-125 . . . . . . . . . . . . . . . . . 29

UQFPH-M-150 . . . . . . . . . . . . . . . . . 29

UQFPH-M-175 . . . . . . . . . . . . . . . . . 29

UQFPH-M-200 . . . . . . . . . . . . . . . . . 29

UQFP-M-100 . . . . . . . . . . . . . . . . . . 29

UQFP-M-125 . . . . . . . . . . . . . . . . . . 29

UQFP-M-150 . . . . . . . . . . . . . . . . . . 29

UQFP-M-175 . . . . . . . . . . . . . . . . . . 29

UQFP-M-200 . . . . . . . . . . . . . . . . . . 29

Z917525-AC . . . . . . . . . . . . . . . . . . . 29

Z917526-AC . . . . . . . . . . . . . . . . . . . 29

CATALOG NO. PG NO. CATALOG NO. PG NO. CATALOG NO. PG NO.

Page 35: Meter Mounting Equipment Commonwealth Edison

35N

OTES

NOTES

35

Page 36: Meter Mounting Equipment Commonwealth Edison

Meter Mounting Equipment & More!Commercial Electrical Enclosures

Residential & Commercial Metering

Commercial Meter Pedestals

Disconnect Devices

Current Transformer Enclosures

RV/MH Pedestals

Temporary Power Outlets

Circuit Breakers

Distribution Unit Substations

Enclosed Circuit Breakers

Safety Switches

Test Switches

REPRESENTATIVECallas/Kingsley845 Lively BoulevardWood Dale, IL 60191Tel: 630-595-7887 Fax: 630-595-6922www.ckelectricalsales.com

ComEd 3/09 (1K)

www.milbankmfg.com

MILBANK MFG. CO.PO Box 419028Kansas City, MO 64141-0028Tel: 816-483-5314 Fax: 816-483-6357Toll Free: 877-483-5314www.milbankmfg.com