![Page 1: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/1.jpg)
Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs
Karthik Ramanathan University of Chicago Kavli Institute for Cosmological Physics SNOLAB Users Meeting 2016
1
![Page 2: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/2.jpg)
DAMIC in brief } DAMIC – Dark Matter In CCDs } Exploit properties of CCDs to detect & analyze particles } WIMP – Weakly Interacting Massive Particle
} Nuclear Recoil
} DAMIC-100 detector currently being deployed at SNOLAB
2
CAB, Fermilab, LPNHE, SNOLAB, U Chicago, U Michigan, UNA, UNAM, UFRJ, U Zürich
![Page 3: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/3.jpg)
Detector & CCD
3
![Page 4: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/4.jpg)
Low Noise
4
Ø Pixel read noise σ ≈ 2e-
Ø Single pixel energy threshold < 100 eV
![Page 5: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/5.jpg)
Latest Exclusion Plot
5 Aguilar-Arevalo et al. 2016, arXiv:1607.07410
![Page 6: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/6.jpg)
Testbed (UChicago)
6
cv
cv
cv
cv
![Page 7: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/7.jpg)
Motivation & Approach
7
} Characterize response of detector at low energy to dominant background – radiogenic γ-‐rays and demonstrate O(10ev) threshold
} Expose to γ-‐ray source } Compton features
![Page 8: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/8.jpg)
Data: NIST PhysRefData XCOM
Cobalt 57 122 KeV γ 6x Cross Section
CO-57 Selection
8
![Page 9: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/9.jpg)
9
Measured Spectrum in DAMIC (UC)
122 keV & 136 keV peaks
1st edge: 39.5 keV
2nd edge: 47.5 keV
Fluorescence peaks
![Page 10: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/10.jpg)
Expected Spectrum
10
} Visible Step features
} Silicon Binding Energies
![Page 11: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/11.jpg)
MCNP Simulation Model
11
![Page 12: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/12.jpg)
Data & Binning
12
charge of several pixels can be added together before moving it to the readout node
some loss of spatial resolution but improved signal to noise (same readout noise but more charge in a binned pixel)
![Page 13: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/13.jpg)
Results
13
60 eVee
![Page 14: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/14.jpg)
e- backscatter?
14
Excess events
e- backscatter?
![Page 15: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/15.jpg)
Takeaway
15
} These measurements demonstrate DAMIC's resolution down to ~60 eV and characterize the spectrum of the major background for the DAMIC WIMP search, low-energy signals from electrons Compton scattered by radiogenic γ-rays.
![Page 16: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/16.jpg)
Dark Current Data
16
} Dark Current: } Thermally generated electrons will contribute to overall signal
measured
} Accurate measurements of DC can not only aid calibration but can also help constrain more exotic DM models: } Hidden Photons, Axions, ALPs
![Page 17: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/17.jpg)
Measuring DC
17
![Page 18: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/18.jpg)
Results
18
Image Overscan
R ~ 1.4E-2 [e- /px/day]
• December 2015 • 9 images • 17 hr exposure/image
![Page 19: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/19.jpg)
Applications
19
• DC provides a floor for CCD interactions à Assume all DC were these exotic particles à Constraint on mixing parameter
![Page 20: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/20.jpg)
Preliminary Results
20
![Page 21: Measurement of Single-Scatter Compton Electrons … of...Measurement of Single-Scatter Compton Electrons and Dark Current in DAMIC CCDs Karthik Ramanathan University of Chicago Kavli](https://reader035.vdocuments.site/reader035/viewer/2022081611/5f0383fa7e708231d4097118/html5/thumbnails/21.jpg)
Questions?