manual er under oversettelse til norsk. - id-kort · manual er under oversettelse suprema inc. 16f...
TRANSCRIPT
Manual er under oversettelse Suprema Inc.
16F Parkview Office Tower, Jeongja-dong, Bundang-gu, Seongnam, Gyeonggi, 463-863 Korea
til norsk.E-mail : [email protected]
Website : www.supremainc.com
Inntil videre bruk Engelsk manual t t å t id
Functions and Spesifikasjoner of the product are subject to changes without notice due to quality
som starter på neste side.
p j p j g q yenhancement or function update. For any inquiry on the product, please contact Suprema Inc.
www.supremainc.com
Innovative Fingerprint Terminal
Installation Guide(ver 1.1)
2
Copyright 2007 Suprema Inc.
Contents
Product Contents 3Connectors for External Interfaces 5Cable and Connector Pinout 6Installation Example 7Product Dimension 8Installation of Wall-mount Bracket 9Power Connection 10USB Cable Connection 11LAN Connection 12Wireless LAN Connection 13RS485 Network Connection 14USB Memory Connection 15Intercom Connection 16Relay Connection – Fail Safe Lock 17Relay Connection – Fail Secure Lock 18Relay Connection - Automatic Door 19TTL Input Port Connection – RTE Switches 20TTL Output Port Connection 21Wiegand Input Connection – External reader 22Wiegand Output Connection – Control Panel 23Ferrite Core Installation 24System Specification 25Electrical Specification 26FCC Rules 27
3
Copyright 2007 Suprema Inc.
Product Contents
Basic Contents
Product Contents
BioStation fingerprint terminal Wall mounting metal bracket
USB cable
Wall mounting screws and holders - 3 ea
Star-shape screw for fixing main body
Star-shape small wrench
5pin, 3pin, 6pin, 4pin, 7pin cable – 1 ea Software CD
4
Copyright 2007 Suprema Inc.
Product Contents
Optional accessories
Plastic stand type B USB fingerprint scanner for enrollment on PC
12V power adaptor Plastic stand type A
InterphoneUSB memory Wireless LAN Access Point
5
Copyright 2007 Suprema Inc.
Connectors for External Interfaces
Bottom
Rear
Slot for USB memory device : USB type A
Slot for PC USB connection : Mini USB
Ethernet cable connector : RJ45
3pin cable connector - Door
6pin cable connector – Input/Output or Wiegand
4pin cable connector - RS485
7pin cable connector - RS232 or BEACon
5pin cable connector – Power and doorphone
12V power adaptor
6
Copyright 2007 Suprema Inc.
Cable and Connector Pinout
PIN PIN DESCRIPTION WIRE1 POWER + (12Vdc) RED2 POWER - BLACK3 Doorphone AUDIO ORANGE4 Doorphone DATA BLUE5 SHIELD GND GRAY
Power & Doorphone
Relay
TTL I/O or Wiegand
RS485
RS232
PIN PIN DESCRIPTION WIRE1 NORMAL OPEN WHITE2 COMMON BLUE3 NORMAL CLOSE ORANGE
PIN PIN DESCRIPTION WIRE1 TTL or Wiegand IN0 BLUE2 TTL or Wiegand IN1 YELLOW3 TTL or Wiegand OUT0 GREEN4 TTL or Wiegand OUT1 WHITE5 GND BLACK6 SHIELD GND GRAY
PIN PIN DESCRIPTION WIRE1 TRX - YELLOW2 TRX + BLUE3 GND BLACK4 SHIELD GND GRAY
PIN PIN DESCRIPTION WIRE1 GND BLACK2 RS-232 TX BLUE3 RS-232 RX YELLOW4 TTL OUT1 WHITE7 SHIELD GND GRAY
Before Start
7
Copyright 2007 Suprema Inc.
Installation Example
Exit ButtonDoor Lock
PC Network hub
6pin cable
3pin cable
7pin cable
Ethernet
USBUSB
RS232
8
Copyright 2007 Suprema Inc.
Product Dimension
BracketFront Side
128
135
128
50
108
112
88
(unit : mm)
9
Copyright 2007 Suprema Inc.
Installation of Wall-mount Bracket
Fix wall mount bracket on a wall using wall mounting screws
Hook BioStation on the wall mount bracket.
Fix BioStation and wall mounting bracket using a star shape screw.
10
Copyright 2007 Suprema Inc.
Power Connection
Method 1
Method 2
Recommended power supply12V ± 10%, at least 1500mA for BioStation alone installation.Comply with standard IEC/EN 60950-1To share the power with other devices, use a power supply with higher current ratings.
11
Copyright 2007 Suprema Inc.
USB Cable Connection
Before Start
PC USB Port
USB A TypeUSB Mini Type
12
Copyright 2007 Suprema Inc.
LAN Connection
13
Copyright 2007 Suprema Inc.
Wireless LAN ConnectionU
SB W
ireless LA
N
USB
Wireless
LAN
Performance of wireless LAN is affected a lot by surrounding environments and the type of AP(Access Point).
The list of APs with compatibility tested with BioStation is as follows.
Buffalo WHR-HP-G54Cisco-Linksys WRTH54GS3COM OfficeConnect 3CRWE554G72T
Using an AP other than these lists, wireless LAN communication may not work propeprly.
Warning If you installed USB Wirless LAN and closed rubber cap,there might be communication error or a fire due tothe overheating.
14
Copyright 2007 Suprema Inc.
RS485 Network Connection
Before Start
15
Copyright 2007 Suprema Inc.
USB Memory Connection
Because of hardware compatibility issue, some USB memory devices may not work properly.
The following is a list of USB memory devices already tested with BioStation.
SanDisk cruzer micro 512MBTranscend JF110 512MBTranscend JF150 512MBSamsung PLEOMAX SPUB-S50 1GBSony Microvault USM512JImation iFLASH Slim 512MBImation Swivel Pro 512MBPQI Intelligent Stick 1GB
16
Copyright 2007 Suprema Inc.
Intercom Connection
Before Start
12345
INTERCOM BIOSTATION
REAR VIEW
(1) Power+(Red)
(2) GND(Black)
(3) Audio(Orange)
(4) Data(Blue)
(5) Shield(Gray)
Cable Shield (Optional)
DC12V POWER
Connect to Intercom Port
5
1
17
Copyright 2007 Suprema Inc.
Relay Connection – Fail Safe Lock
18
Copyright 2007 Suprema Inc.
Relay Connection – Fail Secure Lock
19
Copyright 2007 Suprema Inc.
Relay Connection - Automatic Door
20
Copyright 2007 Suprema Inc.
TTL Input Port Connection – RTE Switches
Request To Exit #2
Request To Exit #1
BioStation
(1) TTL IN0/ Wiegand In 0 (Blue)(2) TTL IN1/ Wiegand In 1 (Yellow)
(5) GND (Black)(6) Shield (Gray)
Cable shield(optional)
21
Copyright 2007 Suprema Inc.
TTL Output Port Connection
22
Copyright 2007 Suprema Inc.
Wiegand Input Connection – External reader
BioStation
GND
Wiegand Data 0 (Green)
Wiegand Data 1 (White)
(1) TTL IN0/ Wiegand In 0 (Blue)(2) TTL IN1/ Wiegand In 1 (Yellow)
(5) GND (Black)
Cable shield(optional)
(6) Shield (Gray)Wiegand reader
GND
Wiegand Input, Data 0Wiegand Input, Data 1
23
Copyright 2007 Suprema Inc.
Wiegand Output Connection – Control Panel
24
Copyright 2007 Suprema Inc.
Ferrite Core Installation
25
Copyright 2007 Suprema Inc.
System Specifications
CPU : Dual CPU (32 bit RISC + 400MHz DSP)Memory : 72MB flash + 34MB RAM Display : 2.5 inch QVGA 16 million color LCD Identification speed : 3,000 fingerprints in 1 secondFingerprint capacity : 50,000 fingerprint templatesLog capacity : 500,000 events Host interface : Wireless LAN (optional), TCP/IP, RS485 PC interface : USB, RS232USB memory slot : USB host 1 relay for deadbolt, EM lock, door strike, or automatic door Wiegand input/output, 4 TTL input/output Built-in microphone and speaker supporting door phone Convenient menu navigation key4 function keys for user defined functions Operation mode : Fingerprint, PIN, PIN+Fingerprint,
Card only*, Card+Fingerprint*, Card+PIN* (*RF model only)RF Card : 125KHz proximity (RF model only)RTC with backup battery (CR2032)**Product size : 135 x 128 x 50 mm (width x length x depth)
Appendix
** CAUTION : RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERY ACCORDING TO THE INSTRUCTIONS
26
Copyright 2007 Suprema Inc.
Electrical Specification
Min. Typ. Max. Notes
Power
Voltage (V) 10.8 12 13.2
Current (mA) - 500 800
TTL/Wiegand Input
VIH (V) 2 - -
VIL (V) - - 0.8
Pull-up resistance (Ω) - 10k -
TTL/Wiegand Output
VOH (V) 4 - - @ IOH = -5mA
VOL (V) - - 1 @ IOL = 5mA
Output resistance (Ω) - 100 -
Relay
Switching capacity (A) - -1
0.330V DC125V AC
Switching power (resistive) - -
30W37.5VA
DCAC
Switching voltage (V) - -110125
DCAC
27
Copyright 2007 Suprema Inc.
FCC Rules
Caution
Warning
Information to User
Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user's authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, user and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guaranteee that interference will not occur in a particular installation; if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1. Reorient / Relocate the receiving antenna.2. Increase the separation between the equipment and receiver.3. Connect the equipment into an outlet on a circuit difference from that
to which the receiver is connected.4. Consult the dealer or an experienced radio/TV technician for help
Suprema Inc.16F Parkview Office Tower, Jeongja-dong, Bundang-gu,
Seongnam, Gyeonggi, 463-863 KoreaE-mail : [email protected]
Website : www.supremainc.com
Functions and specifications of the product are subject to changes without notice due to quality enhancement or function update. For any inquiry on the product, please contact Suprema Inc.