madur - gas analysers - kopia zapasowa madir-en-v01.00...madur rich offer of gas analysers is...

6
CHARACTERISTICS FEATURES TECHNICAL DATA madur rich offer of gas analysers is supplemented by sensors for single gases. Sensors are available in OEM form - perfect solution as a suplement for customer’s larger installation. Measurement results are available as analogue (voltage / current) signal. Sensors are also available in standalone version, with housing, display, data-logger. Ideal when measurement of only one gas component is required, and when measurement environment does not force to use gas conditioner. The second division of sensors concerns measurement method. madur offers NDIR and electrochemical single gas sensors. IR sensor system madIR-D 1 www.madur.com madIR-D-EN-v01.00 [email protected] madur Polska Sp. z o.o. DISCONTINUED

Upload: others

Post on 24-Mar-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: madur - Gas Analysers - Kopia zapasowa madIR-EN-v01.00...madur rich offer of gas analysers is supplemented by sensors for single gases. Sensors are available in OEM form - perfect

CHARACTERISTICS FEATURES TECHNICAL DATA

madur rich offer of gas analysers is supplemented by sensors for single gases.

Sensors are available in OEM form - perfect solution as a suplement for customer’s larger installation. Measurement

results are available as analogue (voltage / current) signal.

Sensors are also available in standalone version, with housing, display, data-logger. Ideal when measurement of

only one gas component is required, and when measurement environment does not force to use gas conditioner.

The second division of sensors concerns measurement method. madur offers NDIR and electrochemical single gas

sensors.

IR sensor system

madIR-D

1

www.madur.com

[email protected] madur Polska Sp. z o.o.

DISCONTINUED

Page 2: madur - Gas Analysers - Kopia zapasowa madIR-EN-v01.00...madur rich offer of gas analysers is supplemented by sensors for single gases. Sensors are available in OEM form - perfect

CHARACTERISTICS FEATURES TECHNICAL DATA

A CO , CH , CO, N O, CHF2 4 2 3vailable for gases: (R23 cooling agent), acetone

2x analogue outputs - one current (0mA ÷ 20mA or 4mA ÷ 20mA) and one voltage (0V ÷ 5V or 0V ÷ 10V)

RS-232C interface for communication with PC computer

Powerful PC programme for administrating sensor

Housing made of ABS

4,5 digit display

Data-logger with SD card for results collection

Aluminium chassis for sensor and its equipment

Modular construction - each aforesaid piece of equipment may be selected independently

Miniature solenoid valve for automatic ventilation and zeroing

Miniature diaphragm pump

NDIR GAS SENSOR WITH OPTIONAL EQUIPMENT

NDIR SENSOR UNIT

LCD DISPLAY 4,5 DIGIT MINIATURE GAS FILTER

DATA - LOGGER MODULEWITH SD CARD

MEMBRANE GAS PUMP

SOLENOID VALVE FOR AUTOMATIC VENTILATION

SOFTWARE & DOCUMENTS CD(NOT IN SCALE)

madIR-D

2 [email protected] madur Polska Sp. z o.o.

DISCONTINUED

Page 3: madur - Gas Analysers - Kopia zapasowa madIR-EN-v01.00...madur rich offer of gas analysers is supplemented by sensors for single gases. Sensors are available in OEM form - perfect

CHARACTERISTICS TECHNICAL DATA

OEM SENSOR

PUMP SOCKET

madIR-D

RS232C SOCKET

DATA-LOGGERSOCKET

OTHER EQUIPMENT (E.G. VALVE) SOCKET

POWER SUPPLY & ANALOGUE OUTPUTS SOCKETS

DISPLAY SOCKET IOUT

GND

UOUT

VDD

GND

RS232C CABLE HYDROPHOBIC FILTER

PROG

RXD

TXD

GND

FEATURES

3 [email protected] madur Polska Sp. z o.o.

DISCONTINUED

Page 4: madur - Gas Analysers - Kopia zapasowa madIR-EN-v01.00...madur rich offer of gas analysers is supplemented by sensors for single gases. Sensors are available in OEM form - perfect

TECHNICAL DATA

NDIR SENSOR IN STANDALONE VERISON INSTALLED IN ABS HOUSING (TWO SIZES OF HOUSING)

LCD DISPLAY POWER LED DATA-LOGGER BAY(UNOCCUPIED)

PG-7 CABLE PASSRS232C CONNECTOR GAS INLET & OUTLET

RS232CCABLE

madIR-D

CHARACTERISTICS FEATURES

4 [email protected] madur Polska Sp. z o.o.

DISCONTINUED

Page 5: madur - Gas Analysers - Kopia zapasowa madIR-EN-v01.00...madur rich offer of gas analysers is supplemented by sensors for single gases. Sensors are available in OEM form - perfect

OEM SENSOR AND ITS EQUIPMENT INSTALLED ON ALUMINIUM CHASSIS (TWO SIZES OF CHASSIS)

TECHNICAL DATA

GAS PUMP(OPTIONAL)

SOLENOID VALVE(OPTIONAL)

NDIR SENSORUNIT

CHASSIS

madIR-D

CHARACTERISTICS FEATURES

5 [email protected] madur Polska Sp. z o.o.

DISCONTINUED

Page 6: madur - Gas Analysers - Kopia zapasowa madIR-EN-v01.00...madur rich offer of gas analysers is supplemented by sensors for single gases. Sensors are available in OEM form - perfect

TECHNICAL DATA

Dimensions (W * H * D)

Storing temperature

Operating conditions

Power supply: input | maximal power consumption

Communication interface with PC computer

Analogue outputs: current | voltage

Ventilation valve (optional): type | maximal pressure

13 V ÷ 30 V DC or 12 V ÷ 24 V AC | 15 W

RS-232C

0/4 mA ÷ 20 mA | 0 V÷ 10 V

2-way | 2 bar

55 mm * 120 mm * 70 mm÷ 224

Weight

T: 10°C ÷ 50°C, RH: 5% ÷ 90% (non-condensing)

0°C ÷ 60°C

60 ÷ 300 g

GENERAL PARAMETERS - OEM VERSION

Chassis material Aluminium, powder coated

Dimensions (W * H * D)

Casing’s material

Display

Gas pump (optional) Diaphragm, ma 0,6l/min. ÷ 0,9l/min.

80 mm * 120 mm * 80 mm

Weight

4,5 digit

ABS

150 g ÷ 450 g

GENERAL PARAMETERS - BOX

Data-logger (optional): type | size | number of results SD flash card | max 4GB | practically unlimited

SHORT VERSION

80 mm * 240 mm * 80 mm

LONG VERSION

200 g ÷ 500 g

madIR-D

CHARACTERISTICS FEATURES

6 [email protected] madur Polska Sp. z o.o.

DISCONTINUED