M B S P M B S P 415v BAHAYA DANGER 415v BAHAYA DANGER T1/S0010 (31) ADUAN KEROSAKAN 04-2696969 TOLL FREE : 1800-88-6777 T1/S0010 (31) ADUAN KEROSAKAN 04-2696969 TOLL FREE : 1800-88-6777

Upload: others

Post on 06-Nov-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: M B S PM B S P€¦ · to street lighting 12x32a 1p ac/g mcb. 18w fluorescent light %%uinternal front view . tnb meter. tools compartment \⠀䤀一䌀䰀唀䐀䔀 䈀䄀匀䤀䌀

M B S P M B S P

415v

BAHAYA

DANGER

415v

BAHAYA

DANGER

T1/S0010 (31)ADUAN KEROSAKAN

04-2696969TOLL FREE : 1800-88-6777

T1/S0010 (31)ADUAN KEROSAKAN

04-2696969TOLL FREE : 1800-88-6777

AutoCAD SHX Text
%%UINTERNAL VIEW
AutoCAD SHX Text
TNB METER
AutoCAD SHX Text
TNB INCOMING
AutoCAD SHX Text
63A MCCB
AutoCAD SHX Text
63A 4P 100mA
AutoCAD SHX Text
6A
AutoCAD SHX Text
16A
AutoCAD SHX Text
ON/OFF
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
3x60/5A CT'S
AutoCAD SHX Text
V/S
AutoCAD SHX Text
V
AutoCAD SHX Text
6A
AutoCAD SHX Text
B
AutoCAD SHX Text
Y
AutoCAD SHX Text
R
AutoCAD SHX Text
N
AutoCAD SHX Text
6A
AutoCAD SHX Text
BP1
AutoCAD SHX Text
C1
AutoCAD SHX Text
TS
AutoCAD SHX Text
6A
AutoCAD SHX Text
BP2
AutoCAD SHX Text
63A 4P (0.1A)
AutoCAD SHX Text
63A 4P (0.1A)
AutoCAD SHX Text
63A 4P (0.1A)
AutoCAD SHX Text
63A 4P (0.1A)
AutoCAD SHX Text
TO STREET LIGHTING 12x32A 1P AC/G MCB
AutoCAD SHX Text
18W FLUORESCENT LIGHT
AutoCAD SHX Text
%%UINTERNAL FRONT VIEW
AutoCAD SHX Text
TNB METER
AutoCAD SHX Text
TOOLS COMPARTMENT (INCLUDE BASIC TOOLS)
AutoCAD SHX Text
B/P
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
40A
AutoCAD SHX Text
40A
AutoCAD SHX Text
40A
AutoCAD SHX Text
V
AutoCAD SHX Text
R
AutoCAD SHX Text
Y
AutoCAD SHX Text
B
AutoCAD SHX Text
F/L
AutoCAD SHX Text
B/P SW1
AutoCAD SHX Text
B/P SW2
AutoCAD SHX Text
13A S/S/O
AutoCAD SHX Text
PHOTOCELL
AutoCAD SHX Text
%%UEXTERNAL FRONT VIEW
AutoCAD SHX Text
%%UEXTERNAL REAR VIEW
AutoCAD SHX Text
%%UEXTERNAL SIDE VIEW
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
%%U(STAINLESS STEEL TYPE)
AutoCAD SHX Text
%%U(STAINLESS STEEL TYPE)
AutoCAD SHX Text
%%U(STAINLESS STEEL TYPE)
AutoCAD SHX Text
BOX FOR PADLOCK
AutoCAD SHX Text
BRASS HINGE
AutoCAD SHX Text
STAINLESS STEEL
AutoCAD SHX Text
PHOTOCELL
AutoCAD SHX Text
VENTILATION C/W PROTECTION
AutoCAD SHX Text
BOX FOR PADLOCK
AutoCAD SHX Text
63A TP
AutoCAD SHX Text
MCCB
AutoCAD SHX Text
63A
AutoCAD SHX Text
4P (100mA)
AutoCAD SHX Text
MOTORISED AUTO RECLOSING SYSTEM (MARS)
AutoCAD SHX Text
RESETABLE SWITCH
AutoCAD SHX Text
MCB CONC. & FUSES COMPT.
AutoCAD SHX Text
VENTILATION C/W WIRE MESH AND PROTECTION
AutoCAD SHX Text
SEE DETAIL `D'
AutoCAD SHX Text
PHOTOCELL
AutoCAD SHX Text
C
AutoCAD SHX Text
PADLOCK BOX REFER DETAIL `E'
AutoCAD SHX Text
PROTECTION BOX
AutoCAD SHX Text
UMBRELLA HOLDER & SCREW (STAINLESS STEEL)
AutoCAD SHX Text
SCADA MBSP COMPARTMENT
AutoCAD SHX Text
CONCRETE PLINTH (H-600mm X L-1200mm X W-800mm)
AutoCAD SHX Text
= COLOUR (CONFEROUS GREEN) MP 338-13041
AutoCAD SHX Text
= COLOUR (GOLDEN YELLOW) P 396-456
AutoCAD SHX Text
= COLOUR (RIVIERA BLUE 38)
AutoCAD SHX Text
= 4.0mm THK PLATE
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
MATERIAL USED: PANEL : 1.5mm THICK STAINLESS STEEL SHEET COLOUR FINISHED : POWDER COATING MP7484T (GREY)
AutoCAD SHX Text
SPECIAL TOOLS
AutoCAD SHX Text
MPSP
AutoCAD SHX Text
SPECIAL KEY
AutoCAD SHX Text
SCREW HEAD SPECIAL FABRICATED FOR MPSP
AutoCAD SHX Text
M10x30 S/S SCREW
AutoCAD SHX Text
MTL : 1.5mm S/S
AutoCAD SHX Text
%%UBASE FRAME DETAIL
AutoCAD SHX Text
STAINLESS STEEL
AutoCAD SHX Text
14x4
AutoCAD SHX Text
%%USECTION A-A TOP VIEW
AutoCAD SHX Text
DOOR HOLDER
AutoCAD SHX Text
FILE HOLDER
AutoCAD SHX Text
VENTILATION DETAIL
AutoCAD SHX Text
NOTE: 1. FRONT & REAR DOOR MUST BE STAINLESS STEEL (4 LAYERS) FRONT & REAR DOOR MUST BE STAINLESS STEEL (4 LAYERS) 2. OUTDOOR TYPE BRASS HINGE (SCREW MUST BE MOUNTED FROM INSIDE PANEL) OUTDOOR TYPE BRASS HINGE (SCREW MUST BE MOUNTED FROM INSIDE PANEL) 3. ALL DIMENSION IS FOLLOW MBSP SPEC ALL DIMENSION IS FOLLOW MBSP SPEC 4. MBSP LOGO MUST BE PROTECTED BY ONE LAYER ANTI STICK PAINT MBSP LOGO MUST BE PROTECTED BY ONE LAYER ANTI STICK PAINT 5. THE FIRST LAYERS SHALL BE COATED WITH NON-STICK PAINT THE FIRST LAYERS SHALL BE COATED WITH NON-STICK PAINT 6. ANTI STICK PAINT SHOULD INCLUDED WITH WARRANTY FOR 2 YEARS ANTI STICK PAINT SHOULD INCLUDED WITH WARRANTY FOR 2 YEARS 7. ALL MATERIAL AND EQUIPMENT MUST BE LISTED UNDER JMAL / EMALALL MATERIAL AND EQUIPMENT MUST BE LISTED UNDER JMAL / EMAL
AutoCAD SHX Text
NOTA: PEMOHON DIKEHENDAKI MENGEMUKAKAN CADANGAN LENGKAP SISTEM PEMANTAU DAN KAWALAN JARAK JAUH (SCADA SYSTEM) YANG PERLU DIPASANG. PEMOHON JUGA PERLU MEMASTIKAN SISTEM YANG DIPASANG MESTILAH BOLEH DIINTEGRASI/BERINTRAKSI DENGAN SISTEM SEDIA ADA.
AutoCAD SHX Text
EXTERNAL BRACKET FOR PADLOCK
AutoCAD SHX Text
DETAIL `E' DETAIL BOX FOR PADLOCK TOP VIEW.
AutoCAD SHX Text
(NOT TO SCALE)
AutoCAD SHX Text
DETAIL BOX FOR PADLOCK FRONT VIEW
AutoCAD SHX Text
(NOT TO SCALE)
AutoCAD SHX Text
SPECIAL KEY
AutoCAD SHX Text
PROTECTION BOX FOR SPECIAL KEY.
AutoCAD SHX Text
3"
AutoCAD SHX Text
4"
AutoCAD SHX Text
4"
AutoCAD SHX Text
20
AutoCAD SHX Text
2
AutoCAD SHX Text
20
AutoCAD SHX Text
2
AutoCAD SHX Text
174
AutoCAD SHX Text
224
AutoCAD SHX Text
130
AutoCAD SHX Text
180
AutoCAD SHX Text
METAL NET
AutoCAD SHX Text
RUBBER
AutoCAD SHX Text
A
AutoCAD SHX Text
DETAIL `D'
AutoCAD SHX Text
(NOT TO SCALE)
AutoCAD SHX Text
MBSP STICKER & NO. FEEDER PILLAR (OUTDOOR TYPE)
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
(RANGE 0-40A)
AutoCAD SHX Text
STAINLESS STEEL SCREW MOUNTED INSIDE
AutoCAD SHX Text
TOOLS COMPARTMENT (INCLUDE BASIC TOOLS)
AutoCAD SHX Text
SCADA MBSP COMPARTMENT
AutoCAD SHX Text
LUKISAN PIAWAIAN FEEDER PILLAR DAN LAMPU JALAN MBSP NO.LUKISAN - MBSP/FPLJ/01/2020-01
AutoCAD SHX Text
BERSIH
AutoCAD SHX Text
BER
AutoCAD SHX Text
A
AutoCAD SHX Text
AY
AutoCAD SHX Text
SE
AutoCAD SHX Text
ND
AutoCAD SHX Text
BA
AutoCAD SHX Text
AR
AutoCAD SHX Text
MAJLIS
AutoCAD SHX Text
PERAI
AutoCAD SHX Text
ANG
AutoCAD SHX Text
BERSIH
AutoCAD SHX Text
BER
AutoCAD SHX Text
A
AutoCAD SHX Text
AY
AutoCAD SHX Text
SE
AutoCAD SHX Text
ND
AutoCAD SHX Text
BA
AutoCAD SHX Text
AR
AutoCAD SHX Text
MAJLIS
AutoCAD SHX Text
PERAI
AutoCAD SHX Text
ANG
AutoCAD SHX Text
ANTI STICK PAINT (OUTSIDE)
AutoCAD SHX Text
STAINLESS STEEL SCREW
AutoCAD SHX Text
L = 1200 mm
AutoCAD SHX Text
W = 800 mm
AutoCAD SHX Text
H2 = 200 mm
AutoCAD SHX Text
4 NOS. STAINLESS STEEL BOLT & NUT
AutoCAD SHX Text
W
AutoCAD SHX Text
H1
AutoCAD SHX Text
H2
AutoCAD SHX Text
H1 = 600 mm
AutoCAD SHX Text
SIDE ELEVATION
AutoCAD SHX Text
SPECIFICATION
Page 2: M B S PM B S P€¦ · to street lighting 12x32a 1p ac/g mcb. 18w fluorescent light %%uinternal front view . tnb meter. tools compartment \⠀䤀一䌀䰀唀䐀䔀 䈀䄀匀䤀䌀

M B S P

415v

BAHAYA

DANGER

M B S P

415v

BAHAYA

DANGER

1 2 3 4

FP##

TNB INCOMING

A

30/5A CT'S

CT'S

AA

V/S6A

15A

6AS/W

ON OFF

LED FLUORESCENT

LIGHT

13A S/S/O

6A

BP SW 2

C1

TS

TIMER

PC

PHOTOCELL

N

SC

AD

A S

YS

TE

M

STANDARD FEEDER PILLAR SCHEMATIC

BP SW 1

SWITCH

EARTHING CHAMBER INSPECTION EARTH CHAMBER DETAILHEAVY DUTY PRECAST CONCRETE

AutoCAD SHX Text
%%UEXTERNAL FENCE FRONT VIEW
AutoCAD SHX Text
%%UEXTERNAL FENCE SIDE VIEW
AutoCAD SHX Text
%%UEXTERNAL FENCE BACK VIEW
AutoCAD SHX Text
HOT DIPPED GALVANIZED SPACING 12.5mm (VERTICAL MAINWIRE) x 75mm (HORIZONTAL CROSSWIRE) & 3.5mm - 4.0mm WIRE DIAMETER ANTI CLIMB FENCING SWING DOOR(FRONT & BACK) INCLUSIVE EXTERNAL BRACKET FOR PADLOCK
AutoCAD SHX Text
75mm X 75mm HOT DIPPED GALVANIZED POST INCLUSIVE FLAT BAR, STAINLESS STEEL BOLT, NUT, POST CAP & OTHER NECESSARY ACCESSORIES
AutoCAD SHX Text
BOX FOR PADLOCK (DETAIL 'F')
AutoCAD SHX Text
FENCE POST & SWING DOOR
AutoCAD SHX Text
DETAIL `F' BOX FOR PADLOCK TOP VIEW
AutoCAD SHX Text
(NOT TO SCALE)
AutoCAD SHX Text
DETAIL 'F' BOX FOR PADLOCK FRONT VIEW
AutoCAD SHX Text
(NOT TO SCALE)
AutoCAD SHX Text
NOTE: FENCE FOR FEEDER PILLAR ONLY APPLICABLE IN INDUSTRIAL AREA & HIGH RISK AREA FOR VANDALISM
AutoCAD SHX Text
OPENING SWING DOOR FOR TNB METER 300mm X 300mm OPENING SWING DOOR FOR PHOTOCELL 300mm X 300mm
AutoCAD SHX Text
LUKISAN PIAWAIAN FEEDER PILLAR DAN LAMPU JALAN MBSP NO.LUKISAN - MBSP/FPLJ/01/2020-02
AutoCAD SHX Text
RCCB
AutoCAD SHX Text
RCCB
AutoCAD SHX Text
RCCB
AutoCAD SHX Text
R2
AutoCAD SHX Text
Y2
AutoCAD SHX Text
B2
AutoCAD SHX Text
R3
AutoCAD SHX Text
Y3
AutoCAD SHX Text
B3
AutoCAD SHX Text
R4
AutoCAD SHX Text
Y4
AutoCAD SHX Text
B4
AutoCAD SHX Text
63A TPN
AutoCAD SHX Text
63A/0.1A
AutoCAD SHX Text
(TYPE AC/G)
AutoCAD SHX Text
M
AutoCAD SHX Text
ELCB
AutoCAD SHX Text
V
AutoCAD SHX Text
R
AutoCAD SHX Text
Y
AutoCAD SHX Text
B
AutoCAD SHX Text
MOTORISED AUTO
AutoCAD SHX Text
RECLOSING SYSTEM
AutoCAD SHX Text
c/w RESET BUTTON
AutoCAD SHX Text
DC
AutoCAD SHX Text
(DIGITAL COUNTER)
AutoCAD SHX Text
AMMETER(0-40A/0.1A)
AutoCAD SHX Text
4 CORE 25mm PVC/SWA/PVC ALU. CABLE IN
AutoCAD SHX Text
HDPE CORUGATED/G.I CLASS 'C' CROSSING PIPE (6")
AutoCAD SHX Text
RCCB
AutoCAD SHX Text
2
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
TNB METER
AutoCAD SHX Text
TNB CUT-OUT FUSE
AutoCAD SHX Text
CABLE BY TNB
AutoCAD SHX Text
DOOR SWITCH (FRONT)
AutoCAD SHX Text
DOOR SWITCH (BACK)
AutoCAD SHX Text
T1, T4, T7 (6 X 180W LED)
AutoCAD SHX Text
T2, T5, T8 (6 X 180W LED)
AutoCAD SHX Text
R1
AutoCAD SHX Text
Y1
AutoCAD SHX Text
B1
AutoCAD SHX Text
T10, T13 (2 X 180W LED)
AutoCAD SHX Text
T11, T14 (2 X 180W LED)
AutoCAD SHX Text
T12, T15 (2 X 180W LED)
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
25KA MCCB
AutoCAD SHX Text
63A TPN
AutoCAD SHX Text
63A TPN (TYPE S)
AutoCAD SHX Text
63A/0.1A
AutoCAD SHX Text
63A TPN
AutoCAD SHX Text
63A/0.1A
AutoCAD SHX Text
(TYPE AC/G)
AutoCAD SHX Text
63A TPN
AutoCAD SHX Text
63A/0.1A
AutoCAD SHX Text
(TYPE AC/G)
AutoCAD SHX Text
63A TPN
AutoCAD SHX Text
63A/0.1A
AutoCAD SHX Text
(TYPE AC/G)
AutoCAD SHX Text
(NOTE : MINIMUM 2 SPARE OUTGOING)
AutoCAD SHX Text
T3, T6, T9 (6 X 180W LED)
AutoCAD SHX Text
(NOTE : MAX 30 POLES FOR TOTAL CIRCUIT)
AutoCAD SHX Text
NOTE : 1. CONNECTION OF THE CONNECTION OF THE EARTHING CONDUCTOR TO THE ELECTRODE SHALL BE BY EXOTHERMIC WELDING CONNECTIONS 2. READING OF THE READING OF THE EARTH RESISTANCE MUST BE BELOW THAN 5 OHM (EARTH<5Ω)
AutoCAD SHX Text
NOTE : MINIMUM 16mm2 SIZE OF WIRING CABLE INSIDE THE FEEDER PILLAR
AutoCAD SHX Text
COPPER TAPE
AutoCAD SHX Text
2 SET EARTHING BAR 25mm X 3mm COPPER BAR
AutoCAD SHX Text
EARTH LOOP
AutoCAD SHX Text
TO MAIN
AutoCAD SHX Text
REMOVABLE CONCRETE COVER
AutoCAD SHX Text
GRD. LEVEL
AutoCAD SHX Text
EARTH CHAMBER
AutoCAD SHX Text
16mm%%C COPPER EARTH ROD
AutoCAD SHX Text
(Depth To 3600mm)
AutoCAD SHX Text
NOS. OF COPPER EARTH ROD
AutoCAD SHX Text
TO ARCHIEVE LESS THAN 5 OHM
AutoCAD SHX Text
135
AutoCAD SHX Text
210
AutoCAD SHX Text
160
AutoCAD SHX Text
320
AutoCAD SHX Text
245
AutoCAD SHX Text
40mm X 25mm HOT DIPPED GALVANIZED HOLLOW SECTION DOOR FRAME & OTHER NECESSARY ACCESSORIES
Page 3: M B S PM B S P€¦ · to street lighting 12x32a 1p ac/g mcb. 18w fluorescent light %%uinternal front view . tnb meter. tools compartment \⠀䤀一䌀䰀唀䐀䔀 䈀䄀匀䤀䌀

M B S P

0.0000

100/110mm PREMIX

300/450mm CRUSHER RUN

AutoCAD SHX Text
WALKWAY WITH CLEARANCE 1500mm FOR UNIVERSAL DESIGN
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
WALKWAY WITH CLEARANCE 1500mm FOR UNIVERSAL DESIGN
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
TYPICAL CROSS SECTION FOR WALKWAY, FEEDER PILLAR, POLE AND MAINHOLE POSITION
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
LUKISAN PIAWAIAN FEEDER PILLAR DAN LAMPU JALAN MBSP NO.LUKISAN - MBSP/FPLJ/01/2020-03
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
SECTION B-B
AutoCAD SHX Text
PRECAST MAINHOLE DETAIL
AutoCAD SHX Text
STEEL BAR FRAME
AutoCAD SHX Text
CONCRETE COVER (100mm THICKNESS)
AutoCAD SHX Text
HANDLE FOR CONCRETE COVER
AutoCAD SHX Text
B
AutoCAD SHX Text
B
AutoCAD SHX Text
SIZE: 600mm x 600mm x 900mm (INTERNAL)
AutoCAD SHX Text
(TO C&S ENGINEER DETAIL / APPROVAL)
AutoCAD SHX Text
HOLE TO 150mm DOUBLE LAYER HDPE CORRUGATED PIPE/150mm G.I. PIPE
AutoCAD SHX Text
SOCKET JOINT PCV TYPE FOR HDPE CORRUGATED PIPE (150mm. Diameter)
AutoCAD SHX Text
450mm
AutoCAD SHX Text
225mm
AutoCAD SHX Text
HOLE TO 150mm DOUBLE LAYER HDPE CORRUGATED PIPE/150mm G.I. PIPE
AutoCAD SHX Text
100mm PVC/HDPE PIPE
AutoCAD SHX Text
FLOW HOLE 25mm
AutoCAD SHX Text
BRICK/PVC SLAB AND SAND LAYER (75mm)
AutoCAD SHX Text
450mm
AutoCAD SHX Text
225mm
AutoCAD SHX Text
SOCKET JOINT G.I. TYPE FOR G.I. PIPE (150mm. Diameter)
AutoCAD SHX Text
G.I. PIPE CLASS 'C' (150mm. Diameter)
AutoCAD SHX Text
TYPICAL SECTION OF G.I. ROAD CROSSING
AutoCAD SHX Text
TYPICAL SECTION OF HDPE CORRUGATED PATH
AutoCAD SHX Text
DOUBLE LAYER HDPE CORRUGATED PIPE 150mm
AutoCAD SHX Text
450mm
AutoCAD SHX Text
225mm
AutoCAD SHX Text
SOCKET JOINT G.I. TYPE FOR G.I. PIPE (150mm. Diameter)
AutoCAD SHX Text
G.I. PIPE CLASS 'C' (150mm. Diameter)
AutoCAD SHX Text
TYPICAL SECTION OF G.I. DRAIN CROSSING
AutoCAD SHX Text
DRAIN
AutoCAD SHX Text
CONCRETE SLAB BEHIND F/P
AutoCAD SHX Text
DRAIN
AutoCAD SHX Text
CONCRETE SLAB BEHIND F/P
AutoCAD SHX Text
WALKWAY WITH CLEARANCE 1500mm FOR UNIVERSAL DESIGN
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
DRAIN
AutoCAD SHX Text
CONCRETE SLAB BEHIND F/P
AutoCAD SHX Text
TYPICAL CROSS SECTION FOR UNIVERSAL DESIGN, FEEDER PILLAR, POLE AND MAINHOLE POSITION
AutoCAD SHX Text
TYPICAL CROSS SECTION FOR UNIVERSAL DESIGN, FEEDER PILLAR, POLE AND MAINHOLE POSITION
AutoCAD SHX Text
TYPICAL CROSS SECTION FOR UNIVERSAL DESIGN, FEEDER PILLAR, POLE AND MAINHOLE POSITION
AutoCAD SHX Text
TYPICAL CROSS SECTION FOR WALKWAY, FEEDER PILLAR, POLE AND MAINHOLE POSITION
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
WALKWAY
Page 4: M B S PM B S P€¦ · to street lighting 12x32a 1p ac/g mcb. 18w fluorescent light %%uinternal front view . tnb meter. tools compartment \⠀䤀一䌀䰀唀䐀䔀 䈀䄀匀䤀䌀

'

R

'

DETACHABLE

BRACKET ARM

NOMINAL PROJECTION

'L'

SLIP JOINT FOR

MOUNTING HEIGHT

8m TO 12m ONLY

91

5

GL

2.5

m (A

NT

I S

TIC

K L

AY

ER

P

AIN

T)

14

50

STANDARD MBSP SPEC - FLANGE MOUNTED TYPE POLE(SIDE VIEW)PROPOSED 'H'm METER HEIGHT LYSAGHT POLE & 'L'm ARM LENGTH

LANTERN AS PER

APPROVED BY JKR

(EMAL/JMAL) & MBSP

(HIGH SPEC & TOP

COVER), IP66 OR

ABOVE C/W SPD 15kA

& NEMA SOCKET

READY FOR SMART

H/DUTY PRECAST EARTH CHAMBER

(STANDARD PRECAST

MBSP MAINHOLE)

NOMINAL PROJECTION

'L'5°

LANTERN AS PER

APPROVED BY JKR

(EMAL/JMAL) & MBSP

(HIGH SPEC & TOP

COVER), IP66 OR

ABOVE C/W SPD 15kA

& NEMA SOCKET

READY FOR SMART

(LENGTH) EARTH ELECTROD16mmØ x 3600mm

EARTH <5Ω (CADWELL)

STANDARD MBSP SLIDINGSERVICE DOOR

C C

DO

OR

S

LID

E D

OW

N

TO

O

PE

N

2 ~ BASE BOARD

MOUNTING LUGS

BASE BOARD

NON-HYGROSCOPIC

MATERIAL

(BY BUYER)

2 ~ BASE BOARD

MOUNTING LUGS

DOOR

STIFFENERS

EARTHING

LUG

SECT C-CPROTECTION

BOX

DOOR COVER w/

'MBSP'

3M STICKER

(BLUE COLOUR)

EARTHING

TERMINATIONS

STANDARD INTERNAL CABLE TERMINATION

2x2.5mm sq. PVC

CABLE TO LANTERN C/W EARTHING

2 NOS 16mmØ 3600mm LENGTH COPPER JACKETED

(MIN. RADIAL THK. 0.25mm) STEEL CORE

FIBER BOARD

40A 2P RCCB (100mA)

SURGE PROTECTION DEVICE

FOR STREET LIGHTING (SERIES SPD)

10A HRC

FIUS

EARTH TERMINAL AT POLE

1C 2.5sq. mm PVC COPPER CABLE

1C 16sq. mm PVC COPPER CABLE/

3mm x 25mm COPPER TAPE

1.CONNECTION OF THE EARTING CONDUCTOR TO THE EARTH

ELECTRODE SHALL BE BY EXOTHERMIC WELDING CONNECTORS

EARTH ELECTRODE C/W PRECAST H/DUTY CONC.

EARTH CHAMBER & REMOVABLE CONC. COVER

(BELOW 5 OHM)

CABLE OUT TAG

CABLE IN TAG

4C

2

5m

m2

A

LU

MIN

IU

M C

AB

LE

4C

2

5m

m2

A

LU

MIN

IU

M C

AB

LE

DETAIL FOR CABLE TERMINATION

INSIDE THE STREET LIGHTING POLE

ALUMINIUM

NEUTRAL LINK

3 BIL. 20A

1P MCB

180W-190W

L.E.D. STREET

LANTERN

NOTE:

GL

SAND FILLING

PVC/SWA/PVC

2 X 4C 25mm2 AL.

1C 16sq. mm PVC COPPER CABLE/

3mm x 25mm COPPER TAPE

FOOTING STRUCTURE AS PER

CIVIL ENGINEER ENDORSEMENT

15

0

10

10

DETAIL AGUSSET

W

4~

1"Ø x NUTS

& WASHERS

RAG BOLT

1"Ø

x 5

80

L

G

BASE FLANGE

C C

DO

OR

S

LID

E D

OW

N

TO

O

PE

N

D

D

STANDARD MBSP SLIDINGSERVICE DOOR (SHARING TYPE)

ENLARGED VIEWSECT D-D

PROTECTION

BOX

POLE

DOOR COVER

STAINLESS STEEL

ANTI-VANDALISM

LOCKING BOLT

LOCK

CLIP

LOCK CLIP STOPPER TACK

WELDED AFTER GALVANIZING

STANDARD MBSP YELLOW REFLECTIVESTICKER ( BAHAYA - 415V )

T1 / S0010ADUAN KEROSAKAN

04-2696969TOLL FREE : 1800-88-6777

T1 / S0010ADUAN KEROSAKAN

04-2696969TOLL FREE : 1800-88-6777

STANDARDMBSP 3 LINECOLOURS POLESTICKERREFLECTIVETYPE - 3M

STANDARD MBSP NUMBERINGPOLE STIKER (OUTDOOR TYPE)NOTE : NUMBERING POLES WILL BEREARRANGE FOR ADDITIONAL POLE

BRACKET ARM

SPIGOT END OF BRACKET ARM

DIAMETER TO SUIT SPIGOT

100

ENTRY OF LUMINAIRE

(INSIDE PVC PIPE / CANNOT BE EXPOSED)

D

D

TECHNICAL INFORMATION

'D'mm

'W'mm

STANDARD BLACK & YELLOWRAILING (G.I. CLASS 'C')

'W'mm

'L'mm

TWIN FLAG HOLDER

AutoCAD SHX Text
LUKISAN PIAWAIAN FEEDER PILLAR DAN LAMPU JALAN MBSP NO.LUKISAN - MBSP/FPLJ/01/2020-04
AutoCAD SHX Text
MOUNTING HEIGHT 'H'm
AutoCAD SHX Text
100
AutoCAD SHX Text
FUSE
AutoCAD SHX Text
IN
AutoCAD SHX Text
IN
AutoCAD SHX Text
OUT
AutoCAD SHX Text
OUT
AutoCAD SHX Text
4 ~ GUSSETS
AutoCAD SHX Text
4 ~ 30Ø x 52 LG. SLOT HOLES
AutoCAD SHX Text
*
AutoCAD SHX Text
M
AutoCAD SHX Text
B
AutoCAD SHX Text
S
AutoCAD SHX Text
P
AutoCAD SHX Text
BERSIH
AutoCAD SHX Text
BER
AutoCAD SHX Text
A
AutoCAD SHX Text
AY
AutoCAD SHX Text
SE
AutoCAD SHX Text
ND
AutoCAD SHX Text
BA
AutoCAD SHX Text
AR
AutoCAD SHX Text
MAJLIS
AutoCAD SHX Text
PERAI
AutoCAD SHX Text
ANG
AutoCAD SHX Text
BERSIH
AutoCAD SHX Text
BER
AutoCAD SHX Text
A
AutoCAD SHX Text
AY
AutoCAD SHX Text
SE
AutoCAD SHX Text
ND
AutoCAD SHX Text
BA
AutoCAD SHX Text
AR
AutoCAD SHX Text
MAJLIS
AutoCAD SHX Text
PERAI
AutoCAD SHX Text
ANG
AutoCAD SHX Text
BAHAYA 415 VOLTS
AutoCAD SHX Text
1. COLUMNS MANUFACTURED IN COMPLIANCE BS EN 40 COLUMNS MANUFACTURED IN COMPLIANCE BS EN 40 2. COLUMNS DESIGN TO WITHSTAND SPEED OF 35M PER SECOND COLUMNS DESIGN TO WITHSTAND SPEED OF 35M PER SECOND 3. MATERIALS USED FOR COLUMNS ARE COMPLIANCE TO BS EN 10025 S275 MATERIALS USED FOR COLUMNS ARE COMPLIANCE TO BS EN 10025 S275 4. COLUMNS SEAM WELDING CONFORMS TO BS 5135 / BS EN 1011-2 COLUMNS SEAM WELDING CONFORMS TO BS 5135 / BS EN 1011-2 5. COLUMNS ARE ANTI-CORRODED BY HOT-DIP GALVANIZED, COMPLIANCE TO COLUMNS ARE ANTI-CORRODED BY HOT-DIP GALVANIZED, COMPLIANCE TO GALVANIZING STANDARD BS EN ISO 1461 / BS 729 6. QUALITY CONTROL PROCEDURE: THE SUPPLIER / MANUFACTURER AND GALVANIZER QUALITY CONTROL PROCEDURE: THE SUPPLIER / MANUFACTURER AND GALVANIZER THE SUPPLIER / MANUFACTURER AND GALVANIZER SHALL BE ISO 9001:2015 ACCREDITED 7. CERTIFIED BY SIRIM QAS INTERNATINAL AND APPROVED BY JKR (EMAL/JMAL)CERTIFIED BY SIRIM QAS INTERNATINAL AND APPROVED BY JKR (EMAL/JMAL)
AutoCAD SHX Text
TANDATANGAN DAN COP JURUTERA PERUNDING CIVIL & STRUCTURE: ................................................................................................................. "SAYA (PERUNDING C&S) MENGESAHKAN BAHAWA PELAN REKABENTUK STRUKTUR KONKRIT TAPAK TIANG LAMPU JALAN INI DISEDIAKAN MENGIKUT JABATAN STANDARD MALAYSIA SERTA AKTA/PERATURAN YANG BERKAITAN DAN BERTANGGUNGJAWAB SEPENUHNYA DI ATAS REKABENTUK DAN PEMASANGAN STRUKTUR TERSEBUT"
AutoCAD SHX Text
NOTE: 1. DETAIL OF FOOTING DIMENSION DETAIL OF FOOTING DIMENSION 2. DETAIL OF FOOTING MATERIALS DETAIL OF FOOTING MATERIALS 3. ALL THE ABOVE MAYBE DIFFERENT ALL THE ABOVE MAYBE DIFFERENT ACCORDING TO THE SIZE OF THE POLE AND SITE CONDITIONS