NOTE: 1. FRONT & REAR DOOR MUST BE STAINLESS STEEL (4 LAYERS) FRONT & REAR DOOR MUST BE STAINLESS STEEL (4 LAYERS) 2. OUTDOOR TYPE BRASS HINGE (SCREW MUST BE MOUNTED FROM INSIDE PANEL) OUTDOOR TYPE BRASS HINGE (SCREW MUST BE MOUNTED FROM INSIDE PANEL) 3. ALL DIMENSION IS FOLLOW MBSP SPEC ALL DIMENSION IS FOLLOW MBSP SPEC 4. MBSP LOGO MUST BE PROTECTED BY ONE LAYER ANTI STICK PAINT MBSP LOGO MUST BE PROTECTED BY ONE LAYER ANTI STICK PAINT 5. THE FIRST LAYERS SHALL BE COATED WITH NON-STICK PAINT THE FIRST LAYERS SHALL BE COATED WITH NON-STICK PAINT 6. ANTI STICK PAINT SHOULD INCLUDED WITH WARRANTY FOR 2 YEARS ANTI STICK PAINT SHOULD INCLUDED WITH WARRANTY FOR 2 YEARS 7. ALL MATERIAL AND EQUIPMENT MUST BE LISTED UNDER JMAL / EMALALL MATERIAL AND EQUIPMENT MUST BE LISTED UNDER JMAL / EMAL
AutoCAD SHX Text
NOTA: PEMOHON DIKEHENDAKI MENGEMUKAKAN CADANGAN LENGKAP SISTEM PEMANTAU DAN KAWALAN JARAK JAUH (SCADA SYSTEM) YANG PERLU DIPASANG. PEMOHON JUGA PERLU MEMASTIKAN SISTEM YANG DIPASANG MESTILAH BOLEH DIINTEGRASI/BERINTRAKSI DENGAN SISTEM SEDIA ADA.
AutoCAD SHX Text
EXTERNAL BRACKET FOR PADLOCK
AutoCAD SHX Text
DETAIL `E' DETAIL BOX FOR PADLOCK TOP VIEW.
AutoCAD SHX Text
(NOT TO SCALE)
AutoCAD SHX Text
DETAIL BOX FOR PADLOCK FRONT VIEW
AutoCAD SHX Text
(NOT TO SCALE)
AutoCAD SHX Text
SPECIAL KEY
AutoCAD SHX Text
PROTECTION BOX FOR SPECIAL KEY.
AutoCAD SHX Text
3"
AutoCAD SHX Text
4"
AutoCAD SHX Text
4"
AutoCAD SHX Text
20
AutoCAD SHX Text
2
AutoCAD SHX Text
20
AutoCAD SHX Text
2
AutoCAD SHX Text
174
AutoCAD SHX Text
224
AutoCAD SHX Text
130
AutoCAD SHX Text
180
AutoCAD SHX Text
METAL NET
AutoCAD SHX Text
RUBBER
AutoCAD SHX Text
A
AutoCAD SHX Text
DETAIL `D'
AutoCAD SHX Text
(NOT TO SCALE)
AutoCAD SHX Text
MBSP STICKER & NO. FEEDER PILLAR (OUTDOOR TYPE)
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
(RANGE 0-40A)
AutoCAD SHX Text
STAINLESS STEEL SCREW MOUNTED INSIDE
AutoCAD SHX Text
TOOLS COMPARTMENT (INCLUDE BASIC TOOLS)
AutoCAD SHX Text
SCADA MBSP COMPARTMENT
AutoCAD SHX Text
LUKISAN PIAWAIAN FEEDER PILLAR DAN LAMPU JALAN MBSP NO.LUKISAN - MBSP/FPLJ/01/2020-01
HOT DIPPED GALVANIZED SPACING 12.5mm (VERTICAL MAINWIRE) x 75mm (HORIZONTAL CROSSWIRE) & 3.5mm - 4.0mm WIRE DIAMETER ANTI CLIMB FENCING SWING DOOR(FRONT & BACK) INCLUSIVE EXTERNAL BRACKET FOR PADLOCK
AutoCAD SHX Text
75mm X 75mm HOT DIPPED GALVANIZED POST INCLUSIVE FLAT BAR, STAINLESS STEEL BOLT, NUT, POST CAP & OTHER NECESSARY ACCESSORIES
AutoCAD SHX Text
BOX FOR PADLOCK (DETAIL 'F')
AutoCAD SHX Text
FENCE POST & SWING DOOR
AutoCAD SHX Text
DETAIL `F' BOX FOR PADLOCK TOP VIEW
AutoCAD SHX Text
(NOT TO SCALE)
AutoCAD SHX Text
DETAIL 'F' BOX FOR PADLOCK FRONT VIEW
AutoCAD SHX Text
(NOT TO SCALE)
AutoCAD SHX Text
NOTE: FENCE FOR FEEDER PILLAR ONLY APPLICABLE IN INDUSTRIAL AREA & HIGH RISK AREA FOR VANDALISM
AutoCAD SHX Text
OPENING SWING DOOR FOR TNB METER 300mm X 300mm OPENING SWING DOOR FOR PHOTOCELL 300mm X 300mm
AutoCAD SHX Text
LUKISAN PIAWAIAN FEEDER PILLAR DAN LAMPU JALAN MBSP NO.LUKISAN - MBSP/FPLJ/01/2020-02
AutoCAD SHX Text
RCCB
AutoCAD SHX Text
RCCB
AutoCAD SHX Text
RCCB
AutoCAD SHX Text
R2
AutoCAD SHX Text
Y2
AutoCAD SHX Text
B2
AutoCAD SHX Text
R3
AutoCAD SHX Text
Y3
AutoCAD SHX Text
B3
AutoCAD SHX Text
R4
AutoCAD SHX Text
Y4
AutoCAD SHX Text
B4
AutoCAD SHX Text
63A TPN
AutoCAD SHX Text
63A/0.1A
AutoCAD SHX Text
(TYPE AC/G)
AutoCAD SHX Text
M
AutoCAD SHX Text
ELCB
AutoCAD SHX Text
V
AutoCAD SHX Text
R
AutoCAD SHX Text
Y
AutoCAD SHX Text
B
AutoCAD SHX Text
MOTORISED AUTO
AutoCAD SHX Text
RECLOSING SYSTEM
AutoCAD SHX Text
c/w RESET BUTTON
AutoCAD SHX Text
DC
AutoCAD SHX Text
(DIGITAL COUNTER)
AutoCAD SHX Text
AMMETER(0-40A/0.1A)
AutoCAD SHX Text
4 CORE 25mm PVC/SWA/PVC ALU. CABLE IN
AutoCAD SHX Text
HDPE CORUGATED/G.I CLASS 'C' CROSSING PIPE (6")
AutoCAD SHX Text
RCCB
AutoCAD SHX Text
2
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
TNB METER
AutoCAD SHX Text
TNB CUT-OUT FUSE
AutoCAD SHX Text
CABLE BY TNB
AutoCAD SHX Text
DOOR SWITCH (FRONT)
AutoCAD SHX Text
DOOR SWITCH (BACK)
AutoCAD SHX Text
T1, T4, T7 (6 X 180W LED)
AutoCAD SHX Text
T2, T5, T8 (6 X 180W LED)
AutoCAD SHX Text
R1
AutoCAD SHX Text
Y1
AutoCAD SHX Text
B1
AutoCAD SHX Text
T10, T13 (2 X 180W LED)
AutoCAD SHX Text
T11, T14 (2 X 180W LED)
AutoCAD SHX Text
T12, T15 (2 X 180W LED)
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
32A SPN
AutoCAD SHX Text
25KA MCCB
AutoCAD SHX Text
63A TPN
AutoCAD SHX Text
63A TPN (TYPE S)
AutoCAD SHX Text
63A/0.1A
AutoCAD SHX Text
63A TPN
AutoCAD SHX Text
63A/0.1A
AutoCAD SHX Text
(TYPE AC/G)
AutoCAD SHX Text
63A TPN
AutoCAD SHX Text
63A/0.1A
AutoCAD SHX Text
(TYPE AC/G)
AutoCAD SHX Text
63A TPN
AutoCAD SHX Text
63A/0.1A
AutoCAD SHX Text
(TYPE AC/G)
AutoCAD SHX Text
(NOTE : MINIMUM 2 SPARE OUTGOING)
AutoCAD SHX Text
T3, T6, T9 (6 X 180W LED)
AutoCAD SHX Text
(NOTE : MAX 30 POLES FOR TOTAL CIRCUIT)
AutoCAD SHX Text
NOTE : 1. CONNECTION OF THE CONNECTION OF THE EARTHING CONDUCTOR TO THE ELECTRODE SHALL BE BY EXOTHERMIC WELDING CONNECTIONS 2. READING OF THE READING OF THE EARTH RESISTANCE MUST BE BELOW THAN 5 OHM (EARTH<5Ω)
AutoCAD SHX Text
NOTE : MINIMUM 16mm2 SIZE OF WIRING CABLE INSIDE THE FEEDER PILLAR
AutoCAD SHX Text
COPPER TAPE
AutoCAD SHX Text
2 SET EARTHING BAR 25mm X 3mm COPPER BAR
AutoCAD SHX Text
EARTH LOOP
AutoCAD SHX Text
TO MAIN
AutoCAD SHX Text
REMOVABLE CONCRETE COVER
AutoCAD SHX Text
GRD. LEVEL
AutoCAD SHX Text
EARTH CHAMBER
AutoCAD SHX Text
16mm%%C COPPER EARTH ROD
AutoCAD SHX Text
(Depth To 3600mm)
AutoCAD SHX Text
NOS. OF COPPER EARTH ROD
AutoCAD SHX Text
TO ARCHIEVE LESS THAN 5 OHM
AutoCAD SHX Text
135
AutoCAD SHX Text
210
AutoCAD SHX Text
160
AutoCAD SHX Text
320
AutoCAD SHX Text
245
AutoCAD SHX Text
40mm X 25mm HOT DIPPED GALVANIZED HOLLOW SECTION DOOR FRAME & OTHER NECESSARY ACCESSORIES
M B S P
0.0000
100/110mm PREMIX
300/450mm CRUSHER RUN
AutoCAD SHX Text
WALKWAY WITH CLEARANCE 1500mm FOR UNIVERSAL DESIGN
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
WALKWAY WITH CLEARANCE 1500mm FOR UNIVERSAL DESIGN
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
TYPICAL CROSS SECTION FOR WALKWAY, FEEDER PILLAR, POLE AND MAINHOLE POSITION
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
LUKISAN PIAWAIAN FEEDER PILLAR DAN LAMPU JALAN MBSP NO.LUKISAN - MBSP/FPLJ/01/2020-03
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
SECTION B-B
AutoCAD SHX Text
PRECAST MAINHOLE DETAIL
AutoCAD SHX Text
STEEL BAR FRAME
AutoCAD SHX Text
CONCRETE COVER (100mm THICKNESS)
AutoCAD SHX Text
HANDLE FOR CONCRETE COVER
AutoCAD SHX Text
B
AutoCAD SHX Text
B
AutoCAD SHX Text
SIZE: 600mm x 600mm x 900mm (INTERNAL)
AutoCAD SHX Text
(TO C&S ENGINEER DETAIL / APPROVAL)
AutoCAD SHX Text
HOLE TO 150mm DOUBLE LAYER HDPE CORRUGATED PIPE/150mm G.I. PIPE
AutoCAD SHX Text
SOCKET JOINT PCV TYPE FOR HDPE CORRUGATED PIPE (150mm. Diameter)
AutoCAD SHX Text
450mm
AutoCAD SHX Text
225mm
AutoCAD SHX Text
HOLE TO 150mm DOUBLE LAYER HDPE CORRUGATED PIPE/150mm G.I. PIPE
AutoCAD SHX Text
100mm PVC/HDPE PIPE
AutoCAD SHX Text
FLOW HOLE 25mm
AutoCAD SHX Text
BRICK/PVC SLAB AND SAND LAYER (75mm)
AutoCAD SHX Text
450mm
AutoCAD SHX Text
225mm
AutoCAD SHX Text
SOCKET JOINT G.I. TYPE FOR G.I. PIPE (150mm. Diameter)
AutoCAD SHX Text
G.I. PIPE CLASS 'C' (150mm. Diameter)
AutoCAD SHX Text
TYPICAL SECTION OF G.I. ROAD CROSSING
AutoCAD SHX Text
TYPICAL SECTION OF HDPE CORRUGATED PATH
AutoCAD SHX Text
DOUBLE LAYER HDPE CORRUGATED PIPE 150mm
AutoCAD SHX Text
450mm
AutoCAD SHX Text
225mm
AutoCAD SHX Text
SOCKET JOINT G.I. TYPE FOR G.I. PIPE (150mm. Diameter)
AutoCAD SHX Text
G.I. PIPE CLASS 'C' (150mm. Diameter)
AutoCAD SHX Text
TYPICAL SECTION OF G.I. DRAIN CROSSING
AutoCAD SHX Text
DRAIN
AutoCAD SHX Text
CONCRETE SLAB BEHIND F/P
AutoCAD SHX Text
DRAIN
AutoCAD SHX Text
CONCRETE SLAB BEHIND F/P
AutoCAD SHX Text
WALKWAY WITH CLEARANCE 1500mm FOR UNIVERSAL DESIGN
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
DRAIN
AutoCAD SHX Text
CONCRETE SLAB BEHIND F/P
AutoCAD SHX Text
TYPICAL CROSS SECTION FOR UNIVERSAL DESIGN, FEEDER PILLAR, POLE AND MAINHOLE POSITION
AutoCAD SHX Text
TYPICAL CROSS SECTION FOR UNIVERSAL DESIGN, FEEDER PILLAR, POLE AND MAINHOLE POSITION
AutoCAD SHX Text
TYPICAL CROSS SECTION FOR UNIVERSAL DESIGN, FEEDER PILLAR, POLE AND MAINHOLE POSITION
AutoCAD SHX Text
TYPICAL CROSS SECTION FOR WALKWAY, FEEDER PILLAR, POLE AND MAINHOLE POSITION
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
FEEDER PILLAR & MAINHOLE POSITION
AutoCAD SHX Text
ROAD KERB
AutoCAD SHX Text
POLE & MAINHOLE POSITION
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
WALKWAY
'
R
'
DETACHABLE
BRACKET ARM
NOMINAL PROJECTION
'L'
SLIP JOINT FOR
MOUNTING HEIGHT
8m TO 12m ONLY
91
5
GL
2.5
m (A
NT
I S
TIC
K L
AY
ER
P
AIN
T)
14
50
5°
STANDARD MBSP SPEC - FLANGE MOUNTED TYPE POLE(SIDE VIEW)PROPOSED 'H'm METER HEIGHT LYSAGHT POLE & 'L'm ARM LENGTH
LANTERN AS PER
APPROVED BY JKR
(EMAL/JMAL) & MBSP
(HIGH SPEC & TOP
COVER), IP66 OR
ABOVE C/W SPD 15kA
& NEMA SOCKET
READY FOR SMART
H/DUTY PRECAST EARTH CHAMBER
(STANDARD PRECAST
MBSP MAINHOLE)
NOMINAL PROJECTION
'L'5°
LANTERN AS PER
APPROVED BY JKR
(EMAL/JMAL) & MBSP
(HIGH SPEC & TOP
COVER), IP66 OR
ABOVE C/W SPD 15kA
& NEMA SOCKET
READY FOR SMART
(LENGTH) EARTH ELECTROD16mmØ x 3600mm
EARTH <5Ω (CADWELL)
STANDARD MBSP SLIDINGSERVICE DOOR
C C
DO
OR
S
LID
E D
OW
N
TO
O
PE
N
2 ~ BASE BOARD
MOUNTING LUGS
BASE BOARD
NON-HYGROSCOPIC
MATERIAL
(BY BUYER)
2 ~ BASE BOARD
MOUNTING LUGS
DOOR
STIFFENERS
EARTHING
LUG
SECT C-CPROTECTION
BOX
DOOR COVER w/
'MBSP'
3M STICKER
(BLUE COLOUR)
EARTHING
TERMINATIONS
STANDARD INTERNAL CABLE TERMINATION
2x2.5mm sq. PVC
CABLE TO LANTERN C/W EARTHING
2 NOS 16mmØ 3600mm LENGTH COPPER JACKETED
(MIN. RADIAL THK. 0.25mm) STEEL CORE
FIBER BOARD
40A 2P RCCB (100mA)
SURGE PROTECTION DEVICE
FOR STREET LIGHTING (SERIES SPD)
10A HRC
FIUS
EARTH TERMINAL AT POLE
1C 2.5sq. mm PVC COPPER CABLE
1C 16sq. mm PVC COPPER CABLE/
3mm x 25mm COPPER TAPE
1.CONNECTION OF THE EARTING CONDUCTOR TO THE EARTH
ELECTRODE SHALL BE BY EXOTHERMIC WELDING CONNECTORS
EARTH ELECTRODE C/W PRECAST H/DUTY CONC.
EARTH CHAMBER & REMOVABLE CONC. COVER
(BELOW 5 OHM)
CABLE OUT TAG
CABLE IN TAG
4C
2
5m
m2
A
LU
MIN
IU
M C
AB
LE
4C
2
5m
m2
A
LU
MIN
IU
M C
AB
LE
DETAIL FOR CABLE TERMINATION
INSIDE THE STREET LIGHTING POLE
ALUMINIUM
NEUTRAL LINK
3 BIL. 20A
1P MCB
180W-190W
L.E.D. STREET
LANTERN
NOTE:
GL
SAND FILLING
PVC/SWA/PVC
2 X 4C 25mm2 AL.
1C 16sq. mm PVC COPPER CABLE/
3mm x 25mm COPPER TAPE
FOOTING STRUCTURE AS PER
CIVIL ENGINEER ENDORSEMENT
15
0
10
10
DETAIL AGUSSET
W
4~
1"Ø x NUTS
& WASHERS
RAG BOLT
1"Ø
x 5
80
L
G
BASE FLANGE
C C
DO
OR
S
LID
E D
OW
N
TO
O
PE
N
D
D
STANDARD MBSP SLIDINGSERVICE DOOR (SHARING TYPE)
ENLARGED VIEWSECT D-D
PROTECTION
BOX
POLE
DOOR COVER
STAINLESS STEEL
ANTI-VANDALISM
LOCKING BOLT
LOCK
CLIP
LOCK CLIP STOPPER TACK
WELDED AFTER GALVANIZING
STANDARD MBSP YELLOW REFLECTIVESTICKER ( BAHAYA - 415V )
STANDARD MBSP NUMBERINGPOLE STIKER (OUTDOOR TYPE)NOTE : NUMBERING POLES WILL BEREARRANGE FOR ADDITIONAL POLE
BRACKET ARM
SPIGOT END OF BRACKET ARM
DIAMETER TO SUIT SPIGOT
100
ENTRY OF LUMINAIRE
5°
(INSIDE PVC PIPE / CANNOT BE EXPOSED)
D
D
TECHNICAL INFORMATION
'D'mm
'W'mm
STANDARD BLACK & YELLOWRAILING (G.I. CLASS 'C')
'W'mm
'L'mm
TWIN FLAG HOLDER
AutoCAD SHX Text
LUKISAN PIAWAIAN FEEDER PILLAR DAN LAMPU JALAN MBSP NO.LUKISAN - MBSP/FPLJ/01/2020-04
AutoCAD SHX Text
MOUNTING HEIGHT 'H'm
AutoCAD SHX Text
100
AutoCAD SHX Text
FUSE
AutoCAD SHX Text
IN
AutoCAD SHX Text
IN
AutoCAD SHX Text
OUT
AutoCAD SHX Text
OUT
AutoCAD SHX Text
4 ~ GUSSETS
AutoCAD SHX Text
4 ~ 30Ø x 52 LG. SLOT HOLES
AutoCAD SHX Text
*
AutoCAD SHX Text
M
AutoCAD SHX Text
B
AutoCAD SHX Text
S
AutoCAD SHX Text
P
AutoCAD SHX Text
BERSIH
AutoCAD SHX Text
BER
AutoCAD SHX Text
A
AutoCAD SHX Text
AY
AutoCAD SHX Text
SE
AutoCAD SHX Text
ND
AutoCAD SHX Text
BA
AutoCAD SHX Text
AR
AutoCAD SHX Text
MAJLIS
AutoCAD SHX Text
PERAI
AutoCAD SHX Text
ANG
AutoCAD SHX Text
BERSIH
AutoCAD SHX Text
BER
AutoCAD SHX Text
A
AutoCAD SHX Text
AY
AutoCAD SHX Text
SE
AutoCAD SHX Text
ND
AutoCAD SHX Text
BA
AutoCAD SHX Text
AR
AutoCAD SHX Text
MAJLIS
AutoCAD SHX Text
PERAI
AutoCAD SHX Text
ANG
AutoCAD SHX Text
BAHAYA 415 VOLTS
AutoCAD SHX Text
1. COLUMNS MANUFACTURED IN COMPLIANCE BS EN 40 COLUMNS MANUFACTURED IN COMPLIANCE BS EN 40 2. COLUMNS DESIGN TO WITHSTAND SPEED OF 35M PER SECOND COLUMNS DESIGN TO WITHSTAND SPEED OF 35M PER SECOND 3. MATERIALS USED FOR COLUMNS ARE COMPLIANCE TO BS EN 10025 S275 MATERIALS USED FOR COLUMNS ARE COMPLIANCE TO BS EN 10025 S275 4. COLUMNS SEAM WELDING CONFORMS TO BS 5135 / BS EN 1011-2 COLUMNS SEAM WELDING CONFORMS TO BS 5135 / BS EN 1011-2 5. COLUMNS ARE ANTI-CORRODED BY HOT-DIP GALVANIZED, COMPLIANCE TO COLUMNS ARE ANTI-CORRODED BY HOT-DIP GALVANIZED, COMPLIANCE TO GALVANIZING STANDARD BS EN ISO 1461 / BS 729 6. QUALITY CONTROL PROCEDURE: THE SUPPLIER / MANUFACTURER AND GALVANIZER QUALITY CONTROL PROCEDURE: THE SUPPLIER / MANUFACTURER AND GALVANIZER THE SUPPLIER / MANUFACTURER AND GALVANIZER SHALL BE ISO 9001:2015 ACCREDITED 7. CERTIFIED BY SIRIM QAS INTERNATINAL AND APPROVED BY JKR (EMAL/JMAL)CERTIFIED BY SIRIM QAS INTERNATINAL AND APPROVED BY JKR (EMAL/JMAL)
AutoCAD SHX Text
TANDATANGAN DAN COP JURUTERA PERUNDING CIVIL & STRUCTURE: ................................................................................................................. "SAYA (PERUNDING C&S) MENGESAHKAN BAHAWA PELAN REKABENTUK STRUKTUR KONKRIT TAPAK TIANG LAMPU JALAN INI DISEDIAKAN MENGIKUT JABATAN STANDARD MALAYSIA SERTA AKTA/PERATURAN YANG BERKAITAN DAN BERTANGGUNGJAWAB SEPENUHNYA DI ATAS REKABENTUK DAN PEMASANGAN STRUKTUR TERSEBUT"
AutoCAD SHX Text
NOTE: 1. DETAIL OF FOOTING DIMENSION DETAIL OF FOOTING DIMENSION 2. DETAIL OF FOOTING MATERIALS DETAIL OF FOOTING MATERIALS 3. ALL THE ABOVE MAYBE DIFFERENT ALL THE ABOVE MAYBE DIFFERENT ACCORDING TO THE SIZE OF THE POLE AND SITE CONDITIONS