lumission catalogus 2012

52
LIGHTING CATALOGUE 2012

Upload: norbert-vitha

Post on 29-Mar-2016

233 views

Category:

Documents


2 download

DESCRIPTION

Lumission catalogus 2012

TRANSCRIPT

Page 1: Lumission catalogus 2012

ligHting catalogue 2012

StationSplein 11K(perron 3a)

2011 lr HaarlempoStbuS 2321

2002 CH Haarlem nederland

t 023 3030 560F 023 3030 569

[email protected]

Page 2: Lumission catalogus 2012

51

Symbolsf looping. Suitable for connection in parallel

g Product suitable for direct mounting on normal flammable materials

h Product suitable for direct mounting on non -flamable materials

c class i Fixture insulated and provided with eart connection

d class ii Fixture double-insulated, not earthed

e class iii Fixture protection against electric shock dependent on connection

to SelV chain (Safe extra low Voltage)

kkkk comply with SelV (Safely extra low Voltage)

G Splash water proof

v pppProduct complies with ppp 650° c glow wire test

W Return on investment (in Years)

P electrical connection without tools

T Plug and Play

U Fixture mounting without tools

Q leD light source

R co2 reduction

S lumission optical System

Fotografie:chris Hoefsmit | Haarlempagina: 14-28-30 Wtc leeuwarden, centrum voor lichtarchitectuuralbert Brunsting | Ruinerwold

Note: the ‘lumission optical System’ idea and concept is recorded and filed by ‘lumission B.V.’ with the official body for intellectual Property under number 7593. We take action against infringement.all content is copyright protected and subject to technical alterations.

Page 3: Lumission catalogus 2012

3

LUMISSION luminaires with a mission Lumission is a new Dutch Lighting fixtures company founDeD by a team of experienceD Lighting professionaLs.we DeVeLop, proDuce anD Distribute high QuaLity energy saVing Lighting fixtures for the proffesionaL marKet. we are conVinceD that soLiD-state Lighting soLutions are mature now anD perfectLy reaDy to repLace traDitionaL energy consuming Light sources. saVing energy wiLL contribute to a sustainabLe enVironment. apart from soLiD-state Lighting configurations the improVeD, state of the art (compact) fLuorescent anD high intensity Discharge soLutions can aLso contribute to reaLize these targets.it is our mission to stimuLate anD proViDe these sustainabLe, energy efficient Lighting soLutions.by offering a transparent range of weLL-DesigneD high QuaLity proDucts that are easy to unDerstanD anD instaLL. we wiLL faciLitate the appLication of the new technoLogies by our main target group, the instaLLers.

It IS OUr gOaL tO be the INStaLLerS preferred eNergy SavINg chOIce.

Page 4: Lumission catalogus 2012
Page 5: Lumission catalogus 2012

INpact Led INpact Led IS a raNge Of dOwNLIghterS deSIgNed fOr geNeraL LIghtINg USINg the LateSt Led techNOLOgy. It IS extreMeLy eNergy effIcIeNt. the LIght IS controlled by loS (lumiSSion optical SyStem).thIS SySteM OfferS the pOSSIbILIty tO chaNge the LIght dIStrIbUtION frOM wIde fLOOd tO fLOOd Or SpOt by USINg exchaNgeabLe LeNSeS. by the deep pOSItIONINg Of the LOS aNd Led array IN the cONe a hIgh LeveL Of LIght cOMfOrt caN be ObtaINed.

5

Page 6: Lumission catalogus 2012

6

dimensions:• ceiling cut-out: 150mm• bezel diameter: 175mm• product hight: 100mm• product hight: 140mmMaterials:• Die-cast aluminium ceiling

trim with same design as other Lumission downlight ranges.

• pc vacuum metalized cone.• Die-cast aluminium heatsink.colors: • white (raL 9010) • silver (raL 9006) • anthracite (raL 7011)Lenses:• standard supplied with wide

flood lens (65°). flood lens (45°) available as accessorie

drivers:• constant current driver

included. • also dimmable 1-10V version

available.accessories:• opal front cover.• flood lens.• conversion ring.

140

(320

0lm

)

100

Ø150

Ø175

700/

1000

/150

0/21

00lm

&&dgkGxST* UWRQ

(3200lm)

(700-2100lm)

Gopal front cover

Page 7: Lumission catalogus 2012

7

circular recessed Led downlight for general lighting. With integrated, 3000K bridgelux® Led array and unique LOS lens system to create different beam-angles. the inpact 150 with 700 or 1000lumens is the solution for replacement of existing cFl fixtures with a diameter of 150mm (13w or 18w cfL)

• ceiling cut-out 150mm, allowing the product to be used in most common existing ceiling openings.

• opal cover available as accessorie• optical system with integrated

bridgelux® LeD array• energy saving up to 40% compared

to cfL solutions (roi <2.5 years).• optical system placed in cone,. high

comfort no glare ugr <19. • LeD-array protected by lens against

damaging and dust • Lifetime of system 50.000h.• 1 fixture, 2 beam angles possible

with exchangeable lenses (acc.)• Lens creates a soft beam. excellent

for downlighting.• including (european supplied)

constant current driver • plug & play versions including cable

with europlug or gst 18i3 wieland connector.

• ceiling springs for easy and fast mounting without tools.

inpact 150 led 700 & 1000 lumen version

Led• high quality bridgelux® LeD array

3000K / cri 82. Lightoutput fixture 700lm. system power consumption 11w.

• high quality bridgelux® LeD array 3000K / cri 82. Lightoutput fixture 1000lm. system power consumption 17w.

• ip44 splash proof, suitable in indoor wet area’s

• fast and easy to install.

Page 8: Lumission catalogus 2012

8

circular recessed Led downlight for general lighting. With integrated 3000K bridgelux® Led array and unique LOS lens system to create different beam angles. replaces 2x18 or 2x26W cFl fixtures.

• optical system with integrated bridgelux® LeD array.

• energy saving up to 40% compared to cfL solutions (roi <2.5 years).

• optical system placed in cone, high comfort no glare ugr <19.

• LeD-array protected by lens against damaging and dust.

• Lifetime of system 50.000h.• 1 fixture, 2 beamangles possible

with exchangeable lenses (acc.).• Lens creates a soft beam.

excellent for downlighting.• including (european supplied)

constant current driver.• plug & play versions including

cable with europlug or gst 18i3 wieland connector.

• ceiling springs for easy and fast mounting without tools.

• ip44 splash proof, suitable in indoor wet area’s.

• fast and easy to install.

inpact 150 led 1500 & 2100 lumen version

Led• high quality bridgelux®

LeD array 3000K / cri 82. Lightoutput fixture 1500lm. system power consumption 27w.

• high quality bridgelux® LeD array 3000K / cri 82. Lightoutput fixture 2100lm.system power consumption 35w.

standard supplied with wideflood lens. flood lens available as accessorie.

Page 9: Lumission catalogus 2012

9

circular recessed Led downlight for general lighting. With integrated 3000K bridgelux® Led array and unique LOS lens system to create different beam angles. replaces 2x32W cFl fixtures or 35W Hit fixtures.

• Designed for area’s with high ceilings (e.g. shops, lobbies).

• energy saving up to 50% compared to cfL solutions (roi <2.5 years).

• advantages compared to hit: - instant start - hot restrike possible - dimmable - better color consistancy

• optical system with integrated bridgelux® LeD array

• extremely high lumen per watt ratio (75lumens per watt!!)

• optical system placed in cone, high comfort no glare ugr <19.

• LeD-array protected by lens against damaging and dust

• Lifetime of system 50.000h.• 1 fixture, 2 beam angles possible

with exchangeable lenses (acc.)• Lens creates a soft beam.

excellent for downlighting.• including 1-10V dimmable

(european supplied) constant current driver

inpact 150 led 3200 lumen version

Led• high quality LeD array 3000K /

cri 82. • Light output fixture 3200lm.

system power consumption 40w.

• plug & play versions including cable with europlug or gst 18i3 wieland connector.

• ceiling springs for easy and fast mounting without tools.

• ip44 splash proof, suitable in indoor wet area’s

• fast and easy to install.

Page 10: Lumission catalogus 2012

10

Page 11: Lumission catalogus 2012

11

*plug & play0000000 = stock article0000000 = lead time 3 weeks** 3200 lumen version available from april 2012

inpact 150 led

conversion ring; the solution for renovation projects as with the efficient led-arrays more compact fixtures can be built compared to compact fluorescent luminaires with a similar luminous flux, it can occur that in a renovation project the existing ceiling cut-out is too large for the intended led luminaire. lumiSSion offers conversion rings for the inpact 150. With this ring the luminaire can be used in ceiling openings of 160 to 240 mm (outer diameter 250 mm).

white silver anthracite700 lumen 4013200 4023200 4033200

4013250 europlug*4013260 wieland*4013400 1-10v dim

1000 lumen 4013201 4023201 40332014013251 europlug*4013261 wieland*4013401 1-10v dim

1500 lumen 4013402 4023402 4033402 1-10v dim4013252 1-10v europlug*4013262 wieland*

2100 lumen 4013203 4023203 40332034013253 europlug*4013263 wieland*4013403 1-10v dim

3200 lumen** 4013405 4023405 4033405 1-10v dim4013455 1-10v europlug*4013465 1-10v wieland*

accessories white silver anthraciteconversion ring 250160-240mm

4010020 4020020 4030020

front cover opal4050020

Lens flood1060023

Page 12: Lumission catalogus 2012

12

dimensions:• ceiling cut-out: 93mm• bezel diameter: 110mm• product hight: 97mmMaterials:• Die-cast aluminium ceiling

trim with same design as other Lumission downlight ranges.

• pc vacuum metalized cone.• Die-cast aluminium heatsink.colors: • white (raL 9010) • silver (raL 9006) • anthracite (raL 7011)Lenses:• standard supplied with

wideflood lens (50°). flood lens (30°) available as accessory.

drivers:• constant current driver

included. • also dimmable 1-10V version

available.accessories:• opal front cover.• flood lens.• conversion ring.

97

Ø93

Ø110

standaard met wide flood lens. flood lens als accessoire verkrijgbaar.

&&dgkGxST* UWRQ

Page 13: Lumission catalogus 2012

13

circular recessed Led downlight for general lighting. With integrated 3000K bridgelux® Led array and unique LOS lens system to create different beam angles. replaces 1x18W & 1x26W cFl fixtures or 50 & 75W halogen fixtures.

• optical system with integrated bridgelux® LeD array. energy saving up to 80% compared to halogen (roi <1,5year) and 40% compared to cfL (roi <2,5year).

• optical system placed in cone, high comfort, no glare ugr <19.

• LeD-array protected by lens against damaging and dust.

• Lifetime of system 50.000h.• 1 fixture, 2 beamangles possible

with exchangeable lens (acc.)• Lens creates a soft beam.

excellent for downlighting as sharp beams create to much contrast in the lightingscheme.

• including (european supplied)constant current driver.

• plug & play versions including cable with europlug or gst 18i3 wieland connector.

• ceiling springs for easy and fast mounting without tools.

• ip44 splash proof, suitable for indoor wet area’s.

inpact 90 led 700 & 1000 lumen version

Led• high quality bridgelux®

LeD array 3000K / cri 82. Lightoutput fixture 700lm. system power consumption 11w.

• high quality bridgelux® LeD array 3000K / cri 82. Lightoutput fixture 1000lm. system power consumption 17w.

Page 14: Lumission catalogus 2012

14

Page 15: Lumission catalogus 2012

15

inpact 90 led

*plug & play0000000 = stock article0000000 = lead time 3 weeks

G Gopen opal front cover

conversion ring; the solution for renovation projects as with the efficient led-arrays more compact fixtures can be built compared to compact fluorescent luminaires with a similar luminous flux, it can occur that in a renovation project the existing ceiling cut-out is too large for the intended led luminaire. lumiSSion offers conversion rings for the inpact 90. With this ring the luminaire can be used in ceiling openings of 100 to 150 mm (outer diameter 160 mm).

700 lumen white silver anthracite3013200 3023200 30332003013250 europlug*3013260 wieland*3013400 1-10v dim

1000 lumen 3013201 3023201 30332013013251 europlug*3013261 wieland*3013401 1-10v dim

accessoriesconversion ring 160100-150mm

3010020 3020020 3030020

opalfront cover 3050020

floodLens 1060023

Page 16: Lumission catalogus 2012
Page 17: Lumission catalogus 2012

INvarIO Ledinvario led (11W) iS a real retroFit For 50W haLOgeN fIxtUreS. wIth a 75MM ceILINg cUt OUt dIaMeter the prOdUct caN be pLaced IN MaNy Of the exIStINg ceILINg hOLeS. WitH tHe integrated led array and loS (lumiSSion optical SyStem) We Have created a SoFt Flood beaM whIch caN be repLaced by a SpOt beaM. the prOdUct IS 2x30° tILtabLe.

17

Page 18: Lumission catalogus 2012

18

dimensions:• ceiling cut-out: 75mm• bezel diameter: 95mm• product hight: 85mmMaterials:• Die-cast aluminium ceiling

trim with same design as other Lumission downlight ranges.

• Die-cast aluminium heatsink.colors: • white (raL 9010)• silver (raL 9006)• anthracite (raL 7011)Lenses:• standard supplied with flood

lens (40°). spot lens (20°) available as accessorie.

drivers:• standard including constant

current driver. • also available including

1-10V dimable driver.

85

30° 30°

Ø75

Ø95 dgkGxST* UVRQ

Page 19: Lumission catalogus 2012

19

adjustable circular led downlight for accent- and general lighting.with integrated bridgelux® Led array and unique LOS lens system to create different beam angles. the Invario Led is the true replacement for the 50W mr16.

• 2x30° tiltable • ceiling cut-out of 75mm. can be

used in existing ceiling cut-outs as many halogen fixtures have a ceiling cut out of 75mm.

• integrated bridgelux® LeD array. energy saving up to 80% compared to halogen 50w mr16, (roi <1,5year).

• Lifetime of system 50.000h• 1 fixture, 2 beamangles possible

with exchangeable lens (acc.)• LeD-array protected by lens

against damaging and dust.• Lens creates a soft beam.• including (european supplied)

constant current driver.• plug & play versions including

cable with europlug or gst 18i2 wieland connector.

• ceiling springs for easy and fast mounting without tools.

• ip44 splash proof, suitable in indoor wet area’s.

Invario 75 Led

Led• high quality bridgelux®

LeD array 3000K / cri 82. Lightoutput fixture 700lm. system power consumption 11w.

standard supplied with flood lens. spot lensavailable as accessorie.

Page 20: Lumission catalogus 2012
Page 21: Lumission catalogus 2012

21

Invario 75 Led 700 lumen white silver anthracite

1013200 1023200 10332001013250 1023250 1033250 europlug*1013260 1023260 1033260 wieland*1013240 1023240 1033240 1-10v dim

accessoriesLens spot

1060021

*plug & play0000000 = stock article0000000 = lead time 3 weeks

Page 22: Lumission catalogus 2012

22

Page 23: Lumission catalogus 2012

INverSO LedinverSo led (14W) iS deSigned aS an alternative to fIxed 50w haLOgeN receSSed fIxtUreS. the paybacK tIMe cOMpared tO 12v 50w haLOgeN IS ShOrter thaN 1 year! by INtegratION Of hOUSINg aNd heatSINK the fIxtUre iS very compact and FitS in eXiSting ceiling cut-outS frOM 70 MM. dUe tO the Large fLaNge the LUMINaIre alSo coverS eXiSting ceiling cut-outS up to 75 mm. tHe combination oF led-array and loS (lumiSSion optical SyStem) createS a diFFuSe Flood beam WHicH can be adJUSted tO a SpOt beaM by repLacINg the LeNS.

23

Page 24: Lumission catalogus 2012

24

dimensions:• ceiling cut-out: 70-75mm• bezel diameter: 85mm• product hight: 85mmMaterials:• Die-cast aluminium ceiling

trim / heatsink with same design as other Lumission downlight ranges.

colors: • white (raL 9010) • silver (raL 9006) • brushed aluminium• anthracite (raL 7011)Lenses:• standard supplied with flood

lens (40°). spot lens (20°) available as accessorie.

drivers:• standard including constant

current driver. • also available including

1-10V dimable driver.

dgkGxST* UVRQ 8

5

Ø70

Ø85

Page 25: Lumission catalogus 2012

25

circular led downlight for accent- and general lighting.with integrated bridgelux® Led array and unique LOS lens system to create different beam angles. the Invario Led with the bridgelux® led array is the true replacement for the 12v 50w halogen.

• ceiling cut-out 70-75mm. Due to this dimension the inverso 70 LeD fits in many existing halogen applications.

• integrated bridgelux® LeD array. energy saving up to 80% compared to 12V 50w mr16 (roi <1year).

• Lifetime of system 50.000h• 1 fixture, 2 beamangles possible

with exchangeable lens (acc.)• LeD-array protected by lens

against damaging and dust.• Lens creates a soft beam.• including (european supplied)

constant current driver.• plug & play versions including

cable with europlug or gst 18i3 wieland connector.

• ceiling springs for easy and fast mounting without tools.

• ip44 splash proof, suitable in indoor wet area’s.

Inverso 70 Led

Led• high quality bridgelux® LeD array

3000K / cri 82. Lightoutput fixture 700lm. system power consumption 11w.

standard supplied with flood lens. spot lensavailable as accessorie.

Page 26: Lumission catalogus 2012

26

Page 27: Lumission catalogus 2012

27

Inverso 70 Led*

*plug & play0000000 = stock article0000000 = lead time 3 weeks* available from april 2012

700 lumen white silver br. alum. anthracite2013200 2023200 2043200 20332002013250 2023250 2043250 2033250 europlug*2013260 2023260 2043260 2033260 wieland*2013240 2023240 2043240 2033240 1-10v dim

accessoriesLens spot

1060021

Page 28: Lumission catalogus 2012
Page 29: Lumission catalogus 2012

INpact 230

29

INpact is a range of DownLighters DesigneD for generaL Lighting using compact fLuorescent Lamps.it combines a high efficient refLector system with a high LeVeL of VisuaL comfort whiLe maintaining a Low recess Depth.INpact can be instaLLeD without any tooLs, resuLting in extremeLy QuicK instaLLation times.

Page 30: Lumission catalogus 2012

30

dimensions:• ceiling cut-out: 230mm• bezel diameter: 250mm• product hight: 125mmMaterials:• pc reflector high gloss

facetted, scratch resistant aluminium vacuum metalized.

• pc gear tray.• Die-cast aluminium ceiling

trim with same design as other Lumission downlight ranges.

colors: • white (raL 9010) • silver (raL 9006) • anthracite (raL 7011)accessories:• opal front cover.• transparant front cover.• ceiling plate.

Ø 230

125

Ø 250

283

TP

&&cgfBGxUTP

Page 31: Lumission catalogus 2012

31

tc-teL 18w gx24-q2tc-teL 26w gx24-q3tc-teL 32w gx24-q3

tc-DeL 18w g24-q2tc-DeL 26w g24-q3

circular recessed downlight for general lighting for compact fluorecent lamps 1x26 up to 2x32w.

• ceiling springs for easy and fast mounting without tools.

• suitable for ceiling thickness up to 30mm.

• easy and fast electrical installation without any tools.

• plug & play versions with integrated gst18i3 wieland ʻin and outʼ connectors.

• integrated european ʻclass aʼ electronic ballast.

• Low glare. • high Lor ( ≥ 70%)• high lightcomfort.

inpact 230 tc-del / tc-tel tc-DeL tc-teL

B G Gopen opal front cover transparant front cover

Page 32: Lumission catalogus 2012

32

Page 33: Lumission catalogus 2012

33

inpact 230

*plug & play0000000 = stock article0000000 = lead time 3 weeks

tc-del tc-tel white silver anthracite1x26/32w 5011202 5021202 50312022x18w 5012201 5022201 50322012x18w 5012271 wieland2x18w 5012301 emerg2x18w 5012401 1-10v dim2x18w 5012601 dali dim2x26/32w 5012202 5022202 50322022x26/32w 5012272 wieland2x26/32w 5012302 emerg2x26/32w 5012402 1-10v dim2x26/32w 5012602 dali dim

accessoriesfront cover opal transparant

5050020 5060020ceiling plate for soft ceilings.

5000020

Page 34: Lumission catalogus 2012
Page 35: Lumission catalogus 2012

INvarIOinvario iS a range oF tiltable (2X30°) aluminium die caSted doWnligHterS deSigned to take energy-SavINg retrOfIt gx5.3 aNd gU10 Led aNd cfL LaMpS. the prOdUctS caN be INStaLLed faSt aNd eaSILy WitHout tHe need oF any toolS. SplaSH prooF (ip44) verSIONS avaILabLe fOr appLIcatION IN wet areaS.

35

Page 36: Lumission catalogus 2012

36

dimensions:• ceiling cut-out: 75mm• bezel diameter: 95mm• product hight: 85mmMaterials:• Die-cast aluminium ceiling

trim, with same design as other Lumission downlight ranges.

• Die-cast aluminium front ring and tilt ring.

• pc connection bracket.colors: • white (raL 9010) • silver (raL 9006) • anthracite (raL 7011)

85

Ø75

Ø95

30° 30°

85

Ø75

Ø95

30° 30°

dgu10 egu5.3 gfgu10 AGx P** U

Page 37: Lumission catalogus 2012

37

adjustable circular downlight for accent and general lighting. designed for retrofit led and cFl lamps. the products are also suitable for (eco) halogen lamps.

• 2x30° tiltable. • ceiling cut-out of 75mm. can be

used in existing ceiling cut-outs.• ceiling springs for easy and fast

mounting without tools. • suitable for ceiling thickness up to

25mm.• easy and fast electrical installation

without any tools (push-in cable clamps and piano key terminal block).

• gu10 version suitable for connection in parallel (looping).

• ip44 versions, splash proof, suitable in wet indoor area’s.

Invario 75

Suitable for following lamptypes (lamps not included):

• gu10 compact fluorescent 230V/7-9-11w

• gu10 es50 230V LeD• gx 5,3 mr16 LeD• also suitable for gu10 max.

50w and gx 5,3 (eco) halogen max. 50w (ip20) max. 35w (ip44)

A

G

Page 38: Lumission catalogus 2012
Page 39: Lumission catalogus 2012

39

Invario 75

0000000 = stock article0000000 = lead time 3 weeks

white silver anthracitegU10 Ip20 1010200 1020200 1030200gx5.3 Ip20 1010100 1020100 1030100

gu10 ip44 1010210 1020210 1030210gX5.3 ip44 1010110 1020110 1030110

Page 40: Lumission catalogus 2012

40

soLutions for energy saVing, Light comfort anD serViceabiLity

relighting is the word that lighting companies use for renovating an existing lighting installation. the first reason to consider a relighting is also

often the most decisive: the cost savings it can bring. a relighting program reduces the total cost of ownership, the total cost you, spread over the scheduled lifetime, will spend on your lighting installation. so purchase, installation, maintenance, power consumption and disposal.

moreover, not only the company itself, but also its employees benefit from a relighting. many old lighting installations are no longer able to meet the new european standard for lightng workplaces this standard states that light conttibutes to the comfort of a stimulating working environment, where productivity, safety and welfare of workers go together.

the past decades efficacy of lamps and luminaires greatly improved. at the same time introduction of electronics in the lighting sector created new opportunities for a better energy efficiency.

religHting & renovation:

Page 41: Lumission catalogus 2012

41

now, with the latest developments in LeD-technology, replacement of conventional luminaires by fixtures with the latest technology is worth considering. that is why we see in the current market that more and more outdated fixtures are replaced by energy efficient and comfortable LeD luminaires.the chart below shows which Lumission luminaire can be used as an alternative for your existing fixture.

cfl lamps hit lamp lowvoltagehalogen lamps

lumissioN led alternative 2x32w 2x26w 2x18w 1x32w 1x26w 1x18w 1x13w 20w cmi 35w cmi 75w 50winpact 150 led 3200lm P Pinpact 150 led 2100lm P Pinpact 150 led 1500lm P Pinpact 150 led 1000lm Pinpact 150 led 700lm P Pinpact 90 led 1000lm P P Pinpact 90 led 700lm P P Pinvario 75 led 700lm Pinverso 70 led 700lm P

Lamptype / Lumission fixtures

Page 42: Lumission catalogus 2012

42

Page 43: Lumission catalogus 2012

43

if you replace an existing fixture by a new luminaire it may occur that the existing ceiling opening does not match with the opening of the new fixture. Lumission offers a solution for every ceiling opening between 70 and 240 mm!! the Lumission luminaires are designed for common ceiling apertures. if the ceiling opening is yet too large a conversion ring can be applied. we

offer a conversion ring for an opening between 100 and 150 mm (for the inpact 90) and for an opening between the 160 and 240 mm (for the inpact 150). the overview below shows which fixtures suits the current ceiling cut-out

for a first indication of the savings, we refer to the paragraph total cost of ownership on the

following pages. on request we can do a tco calculation,for your specific situation.

cutout

lumissioN led alternative 70 – 75mm 75 – 85mm 93 – 100mm 100 – 150mm 150 – 160mm 160 – 240mminpact 150 led 3200lm P P+ ring 250inpact 150 led 2100lm P P+ ring 250inpact 150 led 1500lm P P+ ring 250inpact 150 led 1000lm P P+ ring 250inpact 150 led 700lm P P+ ring 250inpact 90 led 1000lm P P+ ring 160inpact 90 led 700lm P P+ ring 160invario 75 led 700lm Pinverso 70 led 700lm P

cutouts / Lumission fixtures

Page 44: Lumission catalogus 2012

44

LUMISSION’s led philosophy Lumission uses LeD-arrays that are abLe to repLace traDitionaL technoLogies (LiKe haLogen anD fLuorescent Lighting) by integraL soLiD-state Lighting soLutions enabLing high performance anD energy efficient Lighting proDucts.

the use of LeD arrays in combination with the uniQue Lumission opticaL system (LOS) enabLes us to create exceLLent Light Distribution anD proViDe 70% energy saVing compareD with conVentionaL Lamp-fixture combinations of the same output.

lumiSSion optical System (loS)the technology of using lenses in combination with the LeD array and a high quality reflector results in a high optical efficiency of up to 85% and a superb light distribution. in the Lumission optical system the light of the LeD array is concentrated by the internal reflector and then directed by the lens in the required beam angle (spot, flood, wide flood).the exchangeable lenses that are available for creating different beam angles create flexibility to optimize your lighting scheme.Luminaire efficiency is an important issue, but even more important is to have the light directed to the place where you need it.

by our unique LOS we significantly reduce light spillage, thus resulting in a superior high efficiency in the total lighting scheme. the LeD-array is a high-tech component. by positioning the LeD behind the lens it is protected against mechanical damaging (e.g by touching) and dust, which can negatively influence the lumen output.

thermal controlthe LeD arrays used in the Lumission products make use of the metal bond technology (mbt). this technique has proved to give a reduction in thermal resistance by 30-50 percent as compared to LeD solutions available on the market today. furthermore lower thermal resistance is advantageous for the lighting system as it increases the light output and reduces the need for heat sink requirements.Lumission uses optimized passive cooling to dissipate the heat of the LeD efficiently via the heat sink which prevents deterioration of the LeD and other components. by using this reliable thermal control we have an expected lifetime of 50,000 hours with high lumen maintenance resulting in up to 70% of initial lumens available at the end of lifetime (L70). thanks to this reliable thermal control in the Lumission fixtures, the bridgelux® LeD-array has a warranty period of 5 years.

Page 45: Lumission catalogus 2012

45

total cost of ownwershipalthough in general the initial cost for a LeD fixture is higher than for halogen and fluorescent fixtures, the cost over life is much lower thanks to lower energy consumption and the lack of lamp replacement.the average pay-back period for a Lumission LeD fixture compared with a halogen equivalent is 1 to 1.5 years (based on 12 hours usage per day). the average payback period for a Lumission LeD fixture compared to a compact fluorescent equivalent is 2.5 years (based on 12 hours usage per day).

Unique features:• up to 80% energy savings.• exchangeable lenses to create spot, and flood

beam angles. • excellent glare control ugr <19.• good colour rendering, up to ra82..• system lifetime 50.000h, thus no maintenance • offers linear dimming from 20% - 100% with the

designated driver.

0 1 2 3 4 5 6 7 8 9 10� 0

� 100

� 200

� 300

� 400

� 500

� 600

� 700

� 800

Halogen 12V

Halogen 230V

Compact fluorescent

LUMISSION LED

years

TOTAL COST OF OWNERSHIPbased on 12 burning hours/day

Page 46: Lumission catalogus 2012

46

additional benefits• mercury-free• wider range of operating temperatures

(-30°c to +60°c) • no uV and ir radiation• instant start-up• Low maintenance cost• robustness• no heating of illuminated products• not sensitive to frequent switching

colour rendering the colour rendering index indicates to what degree the colour rendering of a light source deviates from that of an incandescent lamp.the colour rendering of Lumission LeD products is cri 82 for the 3000K fixtures.

photobiological safety aspectsunder normal conditions of usage LeD do not give any particular sanitary risk.however, it is in all cases recommended not to look at the light source, whatever it is, from the front. in Lumission LeD fixtures the LeD arrays are positioned deep into the luminaire for additional glare control and visual comfort, thus limiting luminance.

driversfor all LeD fixtures Lumission offers high quality constant current drivers.main specs:• Life 50.000h• ambient temperature range -30°c to + 60°c• high powerfactor 0,9 to 0,97• protection class ii

• enec certified• both standard and 1-10V dimmable versions

available

dimmingthe Lumission LeD fixtures with dimmable drivers are suitable for analog 1-10V dimming.the dimming range is 20%-100%

higher harmonics higher harmonic frequencies are whole multiples of the fundamental frequency (50 hz). higher harmonics are numbered with an integer. so is the third harmonic of our 50 hz fundamental frequency 150 hz and the seventh harmonic 350 hz. figure 1 shows a sine wave with fundamental frequency with the third and the seventh harmonic. the harmonics are added to the ground frequency resulting in the deviation in the form in figure 3.

HOGERE HARMONISCHEN

figure 1: fundamental frequen-cy (red) with third (green) and seventh (yellow) harmonic.

Page 47: Lumission catalogus 2012

when harmonics occur in electrical installations, we are dealing with non-linear changes of voltage and current. the original sine shape is sometimes no longer even recognizable. the harmonics are caused by non-linear electrical components in the installation, for example bad drivers. these components do not follow the voltage but generate current pulses by itself.

this changes the shape of the current and can lead to failures in some devices and high current through the neutral conductor

harmonics can be reduced by means of filters. Lumission uses only drivers that meet the standards with respect to harmonics. below, as an example, the harmonics for inpact 2100lm and the maximum allowed values.

the inrush current the inrush current for the high power Lumission drivers (from 25w) have no surge, meaning that the drivers do not use higher current when switched on than during normal use.

47

0 2 4 6 8 10 12

5

10

15

20

25

30

35Harmonics 32W (limit according to IEC 61000-3-2 table 2)

Harmonic order

Harm

onic

cur

rent

(%)

1

20

40

60

80

100

2 3 4 5 6 7 8 9

figure 2: frequency diagram with relative presence per higher harmonics.

figure 3: result of the sum of ground fequency plus third and seventh harmonics.

Page 48: Lumission catalogus 2012

48

power factorthe power factor is the ratio between the actual power and apparent power (or blind power) in a ac installation.

apparent power: p (s) = u. i (Va) → expressed in volts amps.

actual power: p (w) = u. i (w) → expressed in watts.

the actual power is the actual amount of energy transferred per unit of time, in watts. as a result of a phase shift between voltage and current, or by not sine shaped voltage or current there is a deviation. this deviation is called the phase difference or "cos phi". cos phi = p (w)/p (s)

the above only applies when current and voltage are exactly sine shaped. another cause of a non-ideal power factor is the distortion of a signal. when current or voltage do not have exactly the same shape, the power factor will be less than 1. in that case the signal contains a harmonic distortion. this kind of distortion occurs whith rectifiers and inverters. the result of a power factor less than 1 is that more electric power is transported than there is usefully consumed. this leads to transport losses on the mains.

unlike traditional light sources LeDs do not work on ac power, but on Dc. this Dc is produced by rectifiers, also known as driver. this causes a shift of the signals. the degree of pollution as a result

of this conversion of alternating current to direct current is displayed in the cos phi. cos phi and power factor are often used interchangeably. the power factor gives a more complete picture in case of LeD lamps. the cos phi is only the phase difference between the voltage and current. in the power factor the degree of distortion is included. a sinusoidal voltage and block-shaped current can be in phase and cos phi = 1 while the power factor is smaller than 1.

Page 49: Lumission catalogus 2012

49

Index

Janu

ari 2

012

3013201 15

3013251 15

3013261 15

3013401 15

3023201 15

3033201 15

3050020 15

3060020 15

4010020 11

4013200 11

4013201 11

4013203 11

4013250 11

4013251 11

4013252 11

4013253 11

4013260 11

4013261 11

4013262 11

4013263 11

4013400 11

4013401 11

4013402 11

4013403 11

4013405 11

4013455 11

4013465 11

4020020 11

4023200 11

4023201 11

4023203 11

4023402 11

4023405 11

4030020 11

4033200 11

4033201 11

4033203 11

4033402 11

4033405 11

4050020 11

4060020 11

5000020 33

5011202 33

5012201 33

5012202 33

5012271 33

5012272 33

5012301 33

5012302 33

5012401 33

5012402 33

5012601 33

5012602 33

5021202 33

5022201 33

5022202 33

5031202 33

5032201 33

5032202 33

5050020 33

5060020 33

Page 50: Lumission catalogus 2012
Page 51: Lumission catalogus 2012

51

Symbolsf looping. Suitable for connection in parallel

g Product suitable for direct mounting on normal flammable materials

h Product suitable for direct mounting on non -flamable materials

c class i Fixture insulated and provided with eart connection

d class ii Fixture double-insulated, not earthed

e class iii Fixture protection against electric shock dependent on connection

to SelV chain (Safe extra low Voltage)

kkkk comply with SelV (Safely extra low Voltage)

G Splash water proof

v pppProduct complies with ppp 650° c glow wire test

W Return on investment (in Years)

P electrical connection without tools

T Plug and Play

U Fixture mounting without tools

Q leD light source

R co2 reduction

S lumission optical System

Fotografie:chris Hoefsmit | Haarlempagina: 14-28-30 Wtc leeuwarden, centrum voor lichtarchitectuuralbert Brunsting | Ruinerwold

Note: the ‘lumission optical System’ idea and concept is recorded and filed by ‘lumission B.V.’ with the official body for intellectual Property under number 7593. We take action against infringement.all content is copyright protected and subject to technical alterations.

Page 52: Lumission catalogus 2012

ligHting catalogue 2012

StationSplein 11K(perron 3a)

2011 lr HaarlempoStbuS 2321

2002 CH Haarlem nederland

t 023 3030 560F 023 3030 569

[email protected]