Low Energy Building Design Strategy

Page 2: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Low Carbon Design Aim

• “minimizing the impact on the wider environment through consuming the minimum resources possible in the building’s construction and operation

• whilst providing a healthy comfortable building that meets the occupant’s requirements”

• we need a coherent design and evaluation strategy to help us achieve this!

Page 3: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Building & Systems Design

• meeting the needs of occupants (comfort, utility, etc.) whilst considering environmental impact and meeting a host of other sustainability and legal criteria means that building design is a complex process

• fundamentally a building a complex, integrated energy system

• it will not “work” unless properly designed and analysed

• the majority of buildings in the UK are poorly designed: poor occupant comfort, high energy consumption, reliant on systems to overcome basic design faults

• as a start we need to prioritise our design activities …

Page 4: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Design Hierarchy for Low Energy Performance

Form & Fabric

Efficient Systems & Operation

LZC Energy Supplies• Impact on final energy

performance

demand reduction

energy supplies

Page 5: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Design Hierarchy for Low Energy Performance• the point of the previous slide is that the 1st

priority in a low-energy building design should be:

- maximise the energy efficiency of the building by designing out the need for energy consuming systems (heating, cooling, lighting, etc.)

- maximise the energy efficiency of conventional energy consuming systems

- supply/offset energy demands using local zero-carbon sources

Page 6: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

New Build Design Hierarchy for Low Energy

• without radically reducing the demand of a building (in comparison to the present-day standards) it would be almost impossible to achieve zero carbon operation

Page 7: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction Example

Page 8: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction Example

Page 9: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction Example

Page 10: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction

• All buildings have up to 4 basic energy needs:

Page 11: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction

• before deciding on what demand reduction measures it is worth looking at the demands themselves

• enables reduction measures to be prioritised

• as new build regulations change so energy efficiency priorities will change

• thermal electrical

Page 12: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Heating

• in northern Europe the predominant load in buildings is space heating

• … also the load that can be most effectively tackled

• there are a range of options available depending upon whether a design project is new build or retrofit

• however the basic aims are: – minimise heat loss rate to the

environment (fabric and infiltration)– maximise useful ‘free’ heat gains

Page 13: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Heating

Qf - fabric

Qi - infiltration

Qs - solar

Q g -

gain

s

ifhgs

n

x xr QQQQQQ

dt

dC 1

Qh - heat

Page 14: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Heating

• insulation (walls, windows, doors)

• reduction of infiltration– high quality construction, draft

stripping– MVHR

• maximise useful solar gain– positioning of glazing (south

facing)

Page 15: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Heating

• overall demand reduction measures are one of the most cost-effective ways to reduce carbon emissions – particularly in older buildings/retrofit projects

• Source: EST

Page 16: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Heating

1

10

100

1000

Insulation PV

Savings ratio £/tonne (over 30-year life)

Page 17: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Cooling

• in warmer weather or climates or buildings with high internal heat gains we need space cooling not heating

• note we may have a building that has one set of requirements in winter (minimise heating) and another in summer (minimise cooling) – continental climate

• this tends to be an electrical load, electricity is used for compressors and pumps in the cooling system

• basic aims are:– minimise heat gains from the environment (fabric,

infiltration, solar)

– minimise internal heat gains

– make use of thermal inertia and ‘free’ cooling when available

Page 18: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Cooling

Qs - solar

Q g -

gain

s

ifcgs

n

x xr QQQQQQ

dt

dC 1

Qi - infiltration

Qf - fabric

Qc - cooling

Page 19: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Cooling

• shading (prevent solar radiation getting in)

• reflect solar (albedo)• bring in air from outside when T<Ti

• … otherwise prevent unwanted infiltration

• MVHR• insulation (prevent heat gains

through walls)• make use of thermal mass (plus

free cooling)• … or more exotic strategies

– ground cooling– evaporative cooling

Page 20: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Cooling

• the use of exposed thermal mass is typically employed in buildings (or spaces) likely to experience overheating:

– sunspaces

– areas of high occupancy

– areas with high equipment loads

• thermal mass acts like a sponge – absorbing surplus heat during the day and releasing the heat during the evening

• however to work effectively the release of heat in the evenings needs to be encouraged through flushing of the air inside the building

Page 21: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Cooling

insulation

exposed mass

daytime: Te > Tm

insulation

exposed mass

evening: Te < Tm

ventilation air

Qs - solar

Page 22: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Cooling

Thermal Mass Temps.

0

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Hours

Tem

per

atu

re (

C)

Ambient

Air Temp

Mass Temp

start of night flushend of night flushheat release from mass

heat gain by mass

Page 23: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Cooling

• useful in preventing overheating however:

– slow response to plant input

– more difficult to accurately control internal conditions (plant pre-heat required)

– risk of under-heating on colder mornings

– surface condensation risk

Page 24: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Cooling

• thermally massive buildings are highly dynamic thermal systems

• typically rely on thermal modelling to gauge the effects on performance

• … particularly when also dealing with night flush, etc.

Page 25: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Space Cooling

• testing thermal mass + night flush strategy with ESP-r

Page 26: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Hot Water

• hot water use is very building dependent– very little in offices/shops– medium sized load in dwellings– big load in hotels/hospitals

• there are a variety of measures to reduce the associate energy load

• ‘good housekeeping’:– reducing hot water temperature 60→45oC– Why do we need to supply hot water at 60oC?!

(scalding risk)– to eliminate legionella, just occasionally raise

tank temp to 60oC or use chemical or UV dosing

Page 27: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Hot Water

• technology “fixes”: – storage tank and pipe insulation – more efficient heating devices

(heat pumps, condensing gas boilers)

– aerating taps and nozzles (reduce flow of water)

– time limited taps/shower valves (prevent waste)

– ‘grey water’ heat recovery

Page 28: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Electricity

• as with hot water there are two main strategies for the reduction in use of electricity

• ‘good housekeeping’:– switching appliances off when

not used (better control– avoiding ‘standby’ mode– awareness of energy use ‘smart

meters’

Page 29: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Demand Reduction: Electricity

• Technology “fixes”:– low-energy appliances

(lighting, entertainment, heating, cooling ….)

– low energy fans and pumps (motors)

– daylight responsive lighting– occupancy sensors in

rooms– ‘active’ smart metering

(demand management)

Page 30: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Energy Supplies

• there are two main needs – heat and electricity (electricity could also supply heating/cooling needs)

• as with demands – available resources need to be analysed before deciding on appropriate supply measures

• … these should be appropriate for the demand of the building!

Page 31: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Energy Supplies

• available ‘renewable’ resources are entirely location dependent

Page 32: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Zero Carbon Electricity

• photovoltaics (PV) (solar resource)

• biomass CHP (biomass resource)

• SWECS (wind resource)

Page 33: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Low Carbon Electricity

• CHP (usually gas powered)– to achieve ‘zero carbon’ operation, resulting CO2 emissions

need to be offset by a zero carbon source

Page 34: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Zero Carbon Heat

• solar thermal (solar resource)

• biomass boiler (biomass resource)

Page 35: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Low Carbon Heat

• CHP (gas powered)• Heat pumps (electricity)• … energy consumption

needs to be offset by zero carbon sources

Page 36: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Evaluating Options...

• there is a wide range of options for demand reduction and energy supplies

• how to choose between them?

• this requires performance evaluation

• this is an integral, iterative part of the evolution of a building design

• this type of design model requires feedback (data) on the likely performance of a system ….

Page 37: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Selecting/designing a system

design team

design process

support environment

selection

implications

Page 38: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Performance Evaluation

• an appropriate support environment for the building design process is building environmental simulation

• simulation is the mathematical modelling of a building operating in realistic dynamic conditions

• allows the design team to assess environmental performance (human comfort, energy consumption, emissions, etc.)

Page 39: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Technical Assessment

• simulation enables a design team to make informed choices on a likely system’s performance accounting for the complex interactions

between the fabric-occupants and systems

Page 40: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Technical Assessment

Mathematical model Performance assessment

Page 41: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Exercise – James Weir Building

Page 42: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Exercise – James Weir Building

• develop a “strategy” that would improve the James Weir Building

• this is one of the main teaching buildings in the University – yet is also one of the poorest energy performers, with exceptionally high electricity and space heating demand

• in addition – certain areas of the building (computer labs, lecture spaces in summer) over heat!!

Page 43: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Exercise – James Weir Building

• What could we do to improve this building?

• think about – • the characteristics of the building• uses of the building• constraints on improving energy

performance• feasible improvement measures• costs of improvement measures• ranking improvement measures

Page 44: Low Energy Building Design Strategy. Low Carbon Design Aim “minimizing the impact on the wider environment through consuming the minimum resources possible

Group 1 ANDERSON CRAIG Group 5 BURNS NICHOLAS FARGE YANNICK CHARTON AURELIE CORALIE LOWE GRAEME KENNETH LAINE PIERRE SERRI GAUTHIER MCDAID MORNA

Group 2 ARMOUR CRAIG ALEXANDER Group 6 BERGE MAXIME BRESLIN MARC COCHRANE NEIL FLATMAN ROSS LAMBOT HELENE PASCALINE ANDREE LUNDBERG EBBA MENSAH CLAUDE TOSELLI ALESSANDRA

Group 7 WILSON TOM Group 3 ARTHUR SAMUEL DEMANGE SIMON

BELTAGUI HODA LAVIER BERTRAND GAUDISSART SIMON MICHEL MAURICE RAIHAN HASHIR MACDONALD MICHAEL BICEGO MATHIEU Group 8 BONEY ADAM

DENOMME CHARLOTTE MARIE STEPHANIE Group 4 BARTON ROSS LLAMBIAS SEGOLENE

CASSELS FRASER RUTNOWSKI BENOIT HANROT ASTRID MACGREGOR GRAEME ZAMBEAUX AMELIE