Copper Silver Ionization
![Page 2: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/2.jpg)
Leading Waterborne Bacteria:Water is the Reservoir of Bacteria
ORGANISM SITE OF INFECTION SOURCES OF INFECTION
Pseudomonas Aeruginos
Blood, catheter site, lungs, urinary – high mortality
Potable water, contaminated liquid solutions & disinfectants
Stenotrophomonas maltophilia
Blood, pneumonia, UTI, wound infections, skin, stools, throat
Potable water, distilled water, contaminated liquid solutions & disinfectants
Acinetobacter baumannii
Skin, wound Room humidifiers, distilled water, moisture in mechanical ventilators
Chryseobacterium spp.
Blood Potable water, ice machines
Non-tuberculous Mycobacteria (NTM)
Abscesses and wound infections
Hot water system, shower
Legionella pneumophila
Lung (pneumonia) wound infection; high mortality
Hot water system
Aspergillus species Wound infection Hot water system
2
![Page 3: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/3.jpg)
LiquiTech InVitro Efficacy
3
![Page 4: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/4.jpg)
Water is the Reservoir of Bacteria:Pathogens Live & Proliferate in Biofilm
4
![Page 5: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/5.jpg)
What is Copper Silver Ionization?
Process that introduces (+) charged copper and silver ions into a water system
Ions bond with ( - ) sites on bacterial cell walls and denature proteins
Long term, ionization disperses and destroys biofilms and slimes that harbor Legionella
5
![Page 6: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/6.jpg)
Benefits of Copper Silver Ionization
Ability to penetrate the biofilm on pipe walls Eradicates Legionella in both hot and cold water Copper Silver Ions have a larger residual effect
than most other disinfectants Efficacy does not depend on water
temperature Low consumables cost compared to other
disinfection modalities Non-corrosive
6
![Page 7: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/7.jpg)
Components: Flow Cell
The flow cell chamber houses the copper silver alloy electrodes which release ions into the domestic water supply
7
![Page 8: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/8.jpg)
“Potable water is the most common source of healthcare-associated legionellosis…it was not
until a copper silver Ionization system was installed that we saw a decline in Legionella
numbers”-John Marx, MPH, Lead Infection Preventionist & Microbiologist
University of Wisconsin8
![Page 9: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/9.jpg)
COPPER (CU) SILVER (AG) ELECTRODES
WATER (H20)
H20+ H20+
H20+
H20+ H20+
CU+
CU+ CU+
CU+ CU+
AG+ AG+
AG+ AG+ AG+ COPPER SILVER IONS IN WATER
PASSES THROUGH…
TO CREATE…
Copper Silver Ionization: How It Works
9
![Page 10: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/10.jpg)
Copper Silver Ionization: How It Works
COPPER ION
SILVER ION
BACTERIA
The copper and silver ions disinfect synergistically. The positively charged copper ion will bond to the negative cell wall of the waterborne bacteria. The silver ion will the deconstruct the DNA of the bacteria causing cell death.
10
![Page 11: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/11.jpg)
Target Copper Silver Levels
11
![Page 12: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/12.jpg)
Components: Microprocessor Controller
The POWER SOURCE to the flow cell
Controls the release of the copper and silver ions
“Closed Loop Proportional Control” allowing the system to adjust itself based on water usage to ensure no over or under ionization
12
![Page 13: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/13.jpg)
Components: Ultrasonic Flow Meter
The ultrasonic flow meter communicates the flow rate to the microprocessor controller
Allows for the system to dose copper silver ions based on water demand at any given time achieving “closed loop proportional control” which is unique to the LiquiTech system
13
![Page 14: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/14.jpg)
Remote Engineer Monitoring System (REMS) Provides an outlet for continuous monitoring and trending of system
performance Remote communication & control to LiquiTech’s Engineering team Instant alarm notifications to facilitate immediate response via the
internet
14
![Page 15: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/15.jpg)
Single Flow Cell Hot Water Installation
15
![Page 16: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/16.jpg)
Single Flow Cell Hot Water Return Installation
16
![Page 17: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/17.jpg)
Single Flow Cell Hot Water Return Installation
17
![Page 18: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/18.jpg)
Dual Flow Cell Hot Water Installation
18
![Page 19: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/19.jpg)
Dual Flow Cell Hot Water Installation
19
![Page 20: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/20.jpg)
“Perhaps the most overlooked, important, and controllable source
of nosocomial pathogens is hospital water”
-American Medical Association, 2002
20
![Page 21: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/21.jpg)
Point of Entry Installation
21
![Page 22: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/22.jpg)
Point of Entry Installations
22
![Page 23: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/23.jpg)
Point of Entry Tank Recirculation Installation
23
![Page 24: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/24.jpg)
Point of Entry Installation
24
![Page 25: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/25.jpg)
System Maintenance Schedule
• Handheld Copper Testing• Targeted distal site flushingWeekly• Swapping Flow Cells With Spares• Clean Electrodes
Monthly
• Copper Silver ICP Testing• Legionella Testing
Quarterly
• Recalibration of Flow Cells• Electrode Replacement As-Needed
Annually
25
![Page 26: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/26.jpg)
“Of four disinfection systems investigated by hospital staff, St. Elizabeth choose LiquiTech Copper Silver Ionization.”-Matthew Greis, Director of Plant EngineeringSt. Elizabeth Healthcare
26
![Page 27: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/27.jpg)
Legionella Prevention Guidelines
ACTION LEVELSGUIDELINE 12-2000 & PROPOSED STANDARD
VHA DIRECTIVE & DOD UFC 2-510-01
ENVIRONMENT OF CARE 1.7
28
![Page 28: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/28.jpg)
Your Water Supply: The Myths of Prevention
29
![Page 29: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/29.jpg)
Best Practices of Secondary Disinfection
Non-Corrosive
Energy Efficiency
Residual Protection
Cost Effective
No harmful by-products Won’t erode water pipes Promotes Energy
savings by reducing hot water recirculation temp
Systemic approach for ongoing protection
On-going system maintenance and monitoring
27
![Page 30: LiquiTech Sales Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062316/58a6e37b1a28abef698b6c37/html5/thumbnails/30.jpg)
Contact Information:
Tony DiefenbachVP, WEST COAST & INTERNATIONAL OPERATIONS
Phone: (630) 396-7734Email: [email protected]
30