lindab marine catalogue

Upload: mobilebuffer

Post on 02-Jun-2018

245 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/10/2019 Lindab Marine Catalogue

    1/32

    Ventilation

    MarineVentilation

    Systems

    2001LindabSafe

  • 8/10/2019 Lindab Marine Catalogue

    2/32

  • 8/10/2019 Lindab Marine Catalogue

    3/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    Lindabisol

    LindabSafe

    LindabComfort

    CONTENTS

    GeneralLindab A/S

    General information

    Circular spiral-seamed ducts and fittings, double-jacketed and

    insulated with mineral wool.

    Complete programme in circular spiral-seamed ducts and fittings

    for industrial, comfort and home ventilation. Patented system for

    factory-assembled sealing strip. Type-approved. Conforms to

    leakage Class C.

    Air Distribution Terminals for supply and exhaust. A complete

    range of diffusers, grilles, plenum boxes and air valves.

  • 8/10/2019 Lindab Marine Catalogue

    4/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    Ducts SR

    Description

    SR duct is as standard galvanized steel.

    Alternative materials:

    Aluminium, thickness of plate, max. t = 0.9 mm

    Plastic coated, thickness of plate, max. t = 0.7 mm

    Stainless / Acid proof, thickness of plate, max. t = 0.9 mm

    Provided with external corrugation from diameter 400 andabove. Ducts can be manufactured in special gauges and with

    corrugation on ducts from diameter 250 and larger.

    Other lengths available on request.

    d t L d2

    nom std std.m d 4 kg/mmm mm L

    1 L

    2 L

    3 m m2

    80 0.50 5 3 0.251 0.005 1.2

    100 0.50 5 2 3 0.314 0.008 1.5

    125 0.50 5 2 3 0.393 0.012 1.8

    160 0.50 5 2 3 0.502 0.020 2.3

    180 0.50 5 0.565 0.025 2.6

    200 0.50 5 2 3 0.628 0.031 2.9

    250 0.50 5 2 3 0.785 0.049 3.6

    315 0.60 5 2 3 0.989 0.078 5.5

    400 0.60 5 2 3 1.256 0.126 7.0

    OrderingProduct code: SR aaa bbb

    Typed

    Length L

    L

    t

    d

    L

    td

    With external

    corrugation

    Dimensions

  • 8/10/2019 Lindab Marine Catalogue

    5/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    Ordering

    Product code: BU90 aaa

    Type

    d1

    Bends BU 90/45

    Dimensions

    Description

    Pressed, seam-welded and calibrated.

    rm= 1 x d

    1

    d1 L kgnom mm

    80 105 0.3

    100 100 0.4

    125 125 0.6

    160 160 1.0

    180 180 1.2

    200 200 1.5

    250 250 2.4

    315 315 3.7

    400 * 400 5.1

    L

    d1

    Lrm

    rm= 1 x d

    1

    * Segment bends

    BU 90

    BU 45

    d1

    L kgnom mm

    80 41 0.2

    100 41 0.3

    125 52 0.4

    160 66 0.6

    180 75 0.7

    200 83 0.9

    250 104 1.3

    315 130 2.8

    400 * 162 3.1

    rm= 1 x d

    1

    d1

    Lrm

    L

    * Segment bends

    BU 90

    BU 45

  • 8/10/2019 Lindab Marine Catalogue

    6/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    d1

    L kgnom mm

    80 13 0.2100 13 0.3

    125 16 0.3

    160 21 0.5

    180 24 0.6

    200 26 0.6

    250 * 45 0.8

    315 * 50 1.1

    400 * 53 1.7

    rm= 1 x d

    1

    d1

    L

    L

    rm

    * Segment bends

    Bends

    Dimensions

    Description

    BU 30/BU 15

    d1

    L kgnom mm

    80 27 0.2

    100 27 0.3

    125 33 0.3

    160 43 0.5

    180 48 0.6

    200 54 0.7

    250 67 1.4

    315 * 84 1.3

    400 * 107 2.0

    rm= 1 x d

    1

    d1

    L

    Lr

    m

    Ordering

    Product code: BU30 aaa

    Type

    d1

    Pressed, seam-welded and calibrated.

    rm= 1 x d

    1

    * Segment bends

    BU 30

    BU 15

    BU 30

    BU 15

  • 8/10/2019 Lindab Marine Catalogue

    7/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    RCU

    Dimensions

    d1

    OrderingProduct code: RCU aaa bbb

    Type

    d1

    d2

    Description

    RCU = Centric/pressed

    d2

    L

    d1

    d2

    L kgnom mm

    100 80 20 0.2

    125 80 32 0.2

    100 22 0.2

    160 80 52 0.3

    100 42 0.3

    125 30 0.2

    200 100 64 0.4

    125 50 0.4

    160 30 0.3

    250 125 70 0.5

    160 54 0.5

    200 31 0.6

    315 160 88 0.8

    200 68 0.7

    250 46 0.7

    400 200 103 1.4

    250 78 1.3

    315 54 1.3

    Reducers

  • 8/10/2019 Lindab Marine Catalogue

    8/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    Reducers RCFU

    Dimensions

    Description

    RCFU = Centric - Female/male/pressedd

    1- connections fit externally on LindabSafe fittings.

    OrderingProduct code: RCFU aaa bbb

    Typed

    d2

    d1

    d2

    L

    d1

    d2

    L kgnom mm

    100 80 60 0.2

    125 80 73 0.2

    100 61 0.2

    160 80 95 0.3

    100 80 0.3

    125 67 0.2

    200 100 108 0.4

    125 90 0.4

    160 73 0.3

    250 125* 140 0.5

    160 120 0.5

    200 98 0.6

    315 160 148 0.8

    200 134 0.7

    250 113 0.7

    400 200 183 1.4

    250 158 1.3

    315 140 1.3

    * Built

  • 8/10/2019 Lindab Marine Catalogue

    9/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    Reducers RCLU/RLU

    RLU

    d1

    d2

    d1

    d2

    L kgnom mm

    100 80 58 0.2

    125 80 92 0.3

    100 64 0.3

    160 80 140 0.5

    100 112 0.5

    125 78 0.4

    180 80 167 0.5

    100 140 0.5

    125 106 0.5

    160 58 0.4

    200 80 195 0.6

    100 167 0.6

    125 133 0.6

    160 85 0.5

    180 58 0.4

    250 100 236 1.0

    125 202 0.9

    160 154 0.9

    180 126 0.8

    200 99 0.8

    315 125 291 1.4

    160 243 1.3

    180 216 1.3

    200 188 1.2

    250 119 1.1

    400 160 365 2.3

    180 337 2.2

    200 310 2.2

    250 241 2.1

    315 152 1.8

    Description

    RCLU = Centric. Male/male.

    RLU = Eccentric. Male/male.

    OrderingProduct code: RCLU aaa bbb

    Type

    d1

    d2

    RCLU

    Dimensions

    Dimensions

    d1

    d2

    L

    L

    RCLU

    RLU

  • 8/10/2019 Lindab Marine Catalogue

    10/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    OrderingProduct code: PSU aaa bbb

    Type

    d

    d3

    Collar saddle

    Dimensions

    Description

    PSU

    PSU = Pressed, with aerodynamic flow radius.

    r

    d

    H

    d3

    d d3

    r H kg

    nom mm mm

    80 80 12 52 0.1

    100 80 12 62 0.1

    100 15 65 0.2125 80 12 75 0.1

    100 15 78 0.2

    125 20 83 0.3

    160 80 12 92 0.1

    100 15 95 0.2

    125 20 100 0.3

    160 25 105 0.4

    180 80 12 102 0.1

    100 15 105 0.2

    125 20 110 0.3

    160 25 115 0.4

    180 25 115 0.5

    200 80 12 112 0.1

    100 15 115 0.2

    125 20 115 0.3

    160 25 125 0.4

    180 25 125 0.5

    200 25 125 0.6

    250 80 12 137 0.1

    100 15 140 0.2

    125 20 145 0.2

    160 25 150 0.4

    180 25 150 0.5

    200 25 150 0.5

    250 25 150 0.9315 80 12 170 0.2

    100 15 173 0.2

    125 20 178 0.2

    160 25 182 0.3

    180 25 182 0.5

    200 25 182 0.5

    250 25 182 0.7

    315 25 182 1.3

    400 100 15 215 0.2

    125 20 220 0.2

    160 25 225 0.3

    200 25 225 0.5

    250 25 225 0.7

    315 25 225 1.0

    400 25 225 2.0

  • 8/10/2019 Lindab Marine Catalogue

    11/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    T-pieces TCPU/XCPU

    Description

    XCPU: d4may vary from d

    3.

    TCPU

    Technical data

    d1

    d3

    L

    TCPU

    H

    L

    XCPU

    H

    d3

    d4

    d1

    OrderingProduct code: XCPU aaa bbb ccc

    Type

    d1

    d3

    d4

    Dimensions

    d1

    d3/d

    4 L H kg kg

    nom mm mm TCPU XCPU

    80 80 140 52 0.2 0.3

    100 80 126 65 0.4 0.5

    100 151 65 0.5 0.6125 80 146 75 0.5 0.6

    100 184 78 0.6 0.7

    125 184 83 0.7 0.8

    160 80 140 92 0.6 0.7

    100 184 95 0.7 0.8

    125 229 100 0.8 1.0

    160 229 105 1.2 1.4

    180 80 140 102 0.6 0.7

    100 175 105 0.8 0.9

    125 215 110 0.9 1.1

    160 260 115 1.2 1.4

    180 285 115 1.3 1.5

    200 80 140 112 0.8 0.9

    100 175 115 1.0 1.1

    125 215 115 1.0 1.2

    160 281 125 1.1 1.4

    180 285 125 1.3 1.5

    200 281 125 1.8 1.6

    250 80 156 137 0.9 1.0

    100 175 140 1.2 1.3

    125 220 145 1.3 1.5

    160 256 150 1.5 1.7

    180 306 150 1.7 1.9

    XCPU

  • 8/10/2019 Lindab Marine Catalogue

    12/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    T-pieces TCPU/XCPU

    Dimensions

    250 200 306 150 1.7 1.9

    250 307 150 2.2 2.6

    315 80 156 170 1.7 1.8

    100 175 173 1.7 1.8

    125 220 178 1.8 2.6

    160 256 182 2.0 2.2

    200 306 182 2.4 2.6

    250 350 182 2.9 3.3

    315 390 182 3.4 3.9

    400 100 175 215 2.4 2.5

    125 225 220 2.5 2.7

    160 266 225 2.8 3.0

    200 300 225 3.1 3.3

    250 350 225 3.6 4.1

    315 415 225 4.1 4.6

    400 500 225 5.4 6.0

    d1

    d3/d

    4 L H kg kg

    nom mm mm TCPU XCPU

  • 8/10/2019 Lindab Marine Catalogue

    13/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    T-pieces TCU

    TCU Dimensions

    Description

    OrderingProduct code: TCU aaa bbb

    Type

    d1

    d3

    d1

    H

    TCU

    L

    d3

    d1

    d3

    L H kgnom mm mm

    80 80 170 85 0.4

    100 190 85 0.4

    125 215 85 0.4

    100 80 170 95 0.5

    100 190 95 0.5

    125 215 95 0.6

    160 260 100 0.7

    125 80 170 110 0.6

    100 190 110 0.6

    125 215 110 0.7

    160 260 115 0.8

    180 280 115 0.8

    200 330 130 1.0

    160 80 170 125 0.7

    100 190 125 0.7

    125 215 125 0.8

    160 260 130 0.9

    180 280 130 1.0

    200 330 145 1.1

    250 380 145 1.6

    180 80 170 135 0.7

    100 190 135 0.8

    125 215 135 0.9

    160 260 140 1.0

    180 280 140 1.1

    200 330 155 1.3

    250 380 155 1.7

    200 80 170 145 0.9

    100 190 145 0.9

    125 215 145 1.1

    160 260 150 1.2

    180 280 150 1.3

    200 330 165 1.5

  • 8/10/2019 Lindab Marine Catalogue

    14/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    TCUT-pieces

    Dimensionsd

    1d

    3 L H kg

    nom mm mm

    200 250 380 165 1.8

    315 465 175 2.3

    250 80 170 170 1.2

    100 190 170 1.3

    125 215 170 1.4

    160 260 175 1.6

    180 280 175 1.7

    250 200 330 190 1.8

    250 380 190 2.3

    315 465 200 2.8

    400 570 210 3.5

    315 80 170 205 1.6

    100 190 205 1.7

    125 215 205 1.8

    160 260 210 2.0

    180 280 210 2.2

    200 330 225 2.3

    250 380 225 2.9

    315 465 235 3.5

    400 570 245 4.2

    400 100 190 245 2.4

    125 215 245 2.6

    160 260 250 2.8

    180 280 250 3.0

    200 330 265 3.2

    250 380 265 3.8

    315 465 275 4.3

    400 570 285 5.3

  • 8/10/2019 Lindab Marine Catalogue

    15/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    Connectors

    Dimensions

    Description

    NPU

    NPU connectors are used for joining SR ducts.

    Ordering

    Product code: NPU aaa

    Type

    d1

    d1

    L kgnom mm

    80 8 0.1100 8 0.1

    125 8 0.2

    160 8 0.2

    180 8 0.3

    200 10 0.3

    250 10 0.5

    315 10 0.6

    400 10 1.3

    d1

    L

  • 8/10/2019 Lindab Marine Catalogue

    16/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    Couplings MF

    Dimensions

    Description

    MF is used for joining LindabSafefittings.

    L

    d L kgnom mm

    80 90 0.1

    100 90 0.1

    125 90 0.2

    160 90 0.2

    180 90 0.3

    200 90 0.3

    250 135 0.5

    315 135 0.6

    400 175 1.3

    Ordering

    Product code: MF aaa

    Type

    d

    d

  • 8/10/2019 Lindab Marine Catalogue

    17/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    Take-offs ILRU

    Dimensions

    Description

    ILRU with radius. Fits into SR ducts.

    d1

    r = L kgnom mm

    80 12 0.1

    100 15 0.2

    125 20 0.2

    160 25 0.3

    180 25 0.3

    200 25 0.3

    250 25 0.5

    315 25 0.6

    400 25 1.0

    Ordering

    Product code: ILRU aaa

    Type

    d1

    L

    r

    10

    -15

    d1

  • 8/10/2019 Lindab Marine Catalogue

    18/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    Take-offs ILU

    Dimensions

    Description

    ILU without radius. Fits into SR ducts.

    Ordering

    Product code: ILU aaaType

    d1

    d1

    kgnom

    80 0.1

    100 0.1

    125 0.1

    160 0.1

    180 0.1

    200 0.2

    250 0.3

    315 0.3

    400 0.6

    10

    -15

    d1

  • 8/10/2019 Lindab Marine Catalogue

    19/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    Take-offs ILM

    Dimensions

    Description

    ILM take-off without radius. With female connector, i.e. fits

    directly on LindabSafefittings.

    Ordering

    Product code: ILM aaaType

    d

    d kgnom

    80 0.1

    100 0.1

    125 0.1

    160 0.1

    180 0.1

    200 0.2

    250 0.3

    315 0.3

    400 0.6

    d

    10 - 15 mm

  • 8/10/2019 Lindab Marine Catalogue

    20/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    End caps ESU

    Dimensions

    Description

    ESU fits into SR ducts.

    Ordering

    Product code: ESU aaa

    Type

    d1

    d1

    L kgnom mm

    80 10 0.1

    100 10 0.1

    125 10 0.1

    160 10 0.2

    180 10 0.3

    200 10 0.3

    250 10 0.6

    315 10 0.9

    400 12 1.2

    L

    d1

  • 8/10/2019 Lindab Marine Catalogue

    21/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    Flexible hose TH

    Description

    Hose made of nylon loom mesh with iron welded into the mesh,

    standard length 6 meter, compressed to approx. 1.1 meter,

    available in dimension from 80 to 400 mm, withstands

    temperatures from -20C to 95C.

    Insulated hose is also available, type PSI.

    Dimensions

    d kg

    80 1.7

    100 2.1

    125 2.6160 3.3

    180 3.7

    d kg

    200 4.2

    250 5.2

    315 6.5400 8.4

    d

    L = 6000

    OrderingProduct code: TH aaa

    Type

    d

  • 8/10/2019 Lindab Marine Catalogue

    22/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    Description

    The material of the insulated hose is glass wool, with an

    attached aluminium foil. Inside has the hose PVC-coated

    glassfibre loom and armouring with PVC-covered metal spiral,

    withstands temperatures from -25C to 125C.

    Dimensions

    No Inside Outsidemm mm kg

    PSI 80 80 130 1.65

    PSI 100 102 152 2.25

    PSI 125 127 177 2.70

    PSI 160 160 210 3.60

    PSI 180 180 230 4.50

    PSI 200 203 253 5.40

    d

    L = 3000

    Flexible hose PSI

    OrderingProduct code: PSI aaa

    Type

    d

  • 8/10/2019 Lindab Marine Catalogue

    23/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    SRFC2

    Dimensions

    Description

    Flexible hose

    Flexible tube made of 2x0.07 mm aluminium sheet, standard

    length 5 meter, compressed to approx 1.2 meter, available in

    dimensions from80 mm to 315 mm, withstands temperatures

    up to 200C.

    Assemble with TKS clamp.

    d kg

    80 1.1

    100 1.4

    125 1.7

    160 2.1

    180 2.4

    200 2.7

    250 3.4

    315 4.3

    OrderingProduct code: SRFC2 aaa

    Type

    d

    d

    L = 5000

  • 8/10/2019 Lindab Marine Catalogue

    24/32

  • 8/10/2019 Lindab Marine Catalogue

    25/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    UV25

    UV25/UVH25/UVHGMSuspension clamp

    Dimensions

    25

    8.5

    t = 2.00

    D

    UV25

    Description

    UV-mounting brackets for ducts.

    UV 25 in 25 x 2 mm galvanized sheet.

    UVH 25 in two half parts galvanized sheets 25 x 2 mm.

    UVHGM

    Mounting brackets for ducts.

    UVHGM in two half parts galvanized sheets 25 x 2 mm, and

    with non-vibration rubber and M8 popnut.

    D

    t = 2.00

    UVH2525

    Ordering

    Product code: UV25 aaa

    Type

    D

    UVHGM

    D

    M 8 popnut

    9.5 mm

    25

    D kgnom

    80 0.2

    100 0.2112 * 0.2

    125 0.2

    132 * 0.2

    157 * 0.2

    160 0.2

    180 0.3

    192 * 0.3

    200 0.3

    232 * 0.3

    250 0.3

    315 0.4

    400 0.5

    *) For insulated ducts

    UVHGM

    9.5

  • 8/10/2019 Lindab Marine Catalogue

    26/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    DRU/DSU/DTUDamper

    All dampers are designed so that they also can be built into

    insulated duct systems.

    DRU is a inregulary damper. The damper cup has marks

    showing the position of the damper blade between 0 and 90C.

    The damper blade can also be locked in position with screws,

    and is prepared for reinsulation up to 50 mm.

    DSU is a stop damper for use where complete closure of the air

    flow is not required. The damper cup has marks which show the

    position of the damper blade from 0-90. The damper blade can

    also be locked in position with screws, and is prepared for

    reinsulation up to 50 mm.

    DTU is a closing damper for use where complete closure of the

    air flow is required. The damper blade is a double plate

    equipped with a sealing ring made of non-ageing EPDM rubber

    which makes an airtight seal against the side. The damper cup

    has marks which show the position of the damper blade from

    0-90. The damper blade can be locked in position with screws,

    and is prepared for reinsulation up to 50 mm.

    Dimensions

    Description

    d1

    100

    d1

    DRU DSU DTU

    nom kg kg kg

    80 0.4 0.4 0.4

    100 0.5 0.5 0.5

    125 0.6 0.6 0.7

    160 0.7 0.8 0.9

    180 0.9 1.0 1.1

    200 1.0 1.1 1.2

    250 1.4 1.5 1.8

    315 1.8 2.0 2.5

    400 2.7 2.7 3.6

    50

    OrderingProduct code: DRU aaa

    Type

    d1

    DRU

    50

    d1

    100

    d1

    50

    100

    DSU

    DTU

  • 8/10/2019 Lindab Marine Catalogue

    27/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5The iris damper type IBU is designed for regulation and mea-

    surement of the volume flow in ventilation systems. The special

    iris design provides accurate regulation, smooth flow and low

    noise level.

    IBU as a volume flowmeasuring deviceThe iris damper enables the user to measure the volume flow

    quickly and accurately. The accurate control mechanism gua-

    rantees precise opening of the damper in relation to the scale.

    The damper is equipped with two outputs (to be connected to

    a manometer) for measuring the differential pressure, which

    can be directly converted to volume flow by means of the dia-

    grams.

    The iris damper is a permanent measuring station and the

    control measurements can be taken very quickly at all times.

    Each damper is calibrated individually, giving accurate mea-

    suring results, with the method error being 7%.

    IBU as a regulation damperThe round, adjustable aperture in the iris damper allows re-

    gulation of the volume flow with a smooth flow profile and a

    relatively low noise level. Regulation is easy and fast, and the

    effect of the regulation is immediate.

    Design and materialsIBU is designed in galvanised steel and equipped with a scale

    and measurement output. The connections are fitted with

    LindabSafesealing strips.

    Iris damper IBU

    Description

    OrderingProduct code: IBU aaa

    Type

    d1

    Dimensions

    6

    20

    d1

    D

    L

    d1

    D L kgnom

    80 125 50 0.5

    100 165 60 0.6

    125 188 60 0.9

    160 230 60 1.2

    200 285 60 1.7

    250 335 60 2.3

    315 410 70 3.7

    400 525 70 6.7

    Technical specifications available on request.

  • 8/10/2019 Lindab Marine Catalogue

    28/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    Ordering:

    Product code: FMDU aaa

    Type

    d1

    Flow meter

    Dimension

    Description

    FMDU

    FMDU is a compact flow meter of short length combining the

    damper and the volume flow measurement. It is used for

    regulation of the volume of air and is equipped with a measure

    terminal for attaching a monometer. It is avaiable is sizes from80 to 315 mm and is prepared for reinsulation up to 50 mm.

    d1 L kgnom

    80 165 0.7

    100 165 0.8

    125 165 0.9

    160 165 1.1

    200 230 1.5

    250 275 2.1

    315 275 2.7

    Technical specifications available on request.

    L

    d

    1

  • 8/10/2019 Lindab Marine Catalogue

    29/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5OrderingProduct code: SLU aaa bbb

    Type

    d1

    L

    SLU/SLGUCircular silencers

    L D

    d1

    Dimensions

    DescriptionDiameters315 mm are supplied with 2 loose connecters type

    NPU, which must be fitted before the silencer is installed.

  • 8/10/2019 Lindab Marine Catalogue

    30/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    SLUCircular silencers

    Dimensions

    Damping in (dB)d

    1D for medium

    Product code nom nom L frequency (Hz)mm mm mm 125 250 500 1000 2000 4000 kg

    SLU 80- 300 80 180 300 5 11 15 25 28 23 2

    80- 600 80 180 600 7 18 26 29 29 24 3

    80- 900 80 180 900 9 26 38 33 30 26 5

    80-1200 80 180 1200 11 30 36 37 31 27 7

    SLU 100- 300 100 200 300 5 9 12 20 25 17 2

    100- 600 100 200 600 7 15 25 33 29 24 3

    100- 900 100 200 900 9 22 32 36 33 31 5100-1200 100 200 1200 11 25 36 39 37 38 7

    SLU 125- 300 125 224 300 3 7 14 19 16 19 3

    125- 600 125 224 600 5 13 21 37 37 31 4

    125- 900 125 224 900 7 16 28 38 38 35 7

    125-1200 125 224 1200 9 20 34 39 39 36 9

    SLU 160- 300 160 260 300 2 8 12 15 15 14 3

    160- 600 160 260 600 3 11 22 33 42 29 6

    160- 900 160 260 900 8 14 23 39 37 25 8

    160-1200 160 260 1200 11 19 35 38 47 41 10

    SLU 200- 300 200 315 300 2 4 8 15 18 13 4

    200- 600 200 315 600 4 8 15 31 28 20 7

    200- 900 200 315 900 8 9 20 32 35 23 10

    200-1200 200 315 1200 11 17 26 34 40 26 12

    SLU 250- 600 250 355 600 6 9 13 24 15 15 9

    250- 900 250 355 900 8 11 20 33 24 18 12

    250-1200 250 355 1200 10 13 25 38 29 24 15

    SLU 315- 600 315 500 600 5 5 11 19 12 10 12

    315- 900 315 500 900 7 9 16 30 18 14 18

    315-1200 315 500 1200 9 12 21 36 18 17 24

    SLU 400- 600 400 600 600 5 6 9 13 10 7 16

    400- 900 400 600 900 7 7 14 22 15 13 22

    400-1200 400 600 1200 7 10 14 22 18 13 32

    Max. outer diameter = D + 25 mmInsulation with Rockwool.

  • 8/10/2019 Lindab Marine Catalogue

    31/32

    All Lindabs products are registered according to IPR. Right to alteration reserved

    LindabSafe

    1

    2

    3

    4

    5

    SLGUCircular silencers

    DimensionsSLGU, 150 mm insulation

    Damping in (dB)d

    1D for medium

    Product code nom nom L frequency (Hz)mm mm mm 125 250 500 1000 2000 4000 kg

    SLGU 80-1000 80 400 1000 26 22 27 50 55 47 19

    SLGU 100-1000 100 400 1000 25 36 42 59 53 47 21

    SLGU 125-1000 125 450 1000 22 34 38 51 50 40 22

    125-1200 125 450 1200 21 36 40 62 55 46 25

    SLGU 160-1000 160 450 1000 16 28 40 51 52 28 22

    160-1200 160 450 1200 17 33 44 58 56 32 25

    SLGU 200-1000 200 500 1000 14 24 32 45 36 24 26

    200-1200 200 500 1200 15 25 36 49 42 26 31

    SLGU 250-1000 250 560 1000 12 22 31 37 31 18 30

    250-1200 250 560 1200 15 26 36 41 34 20 35

    Max. outer diameter = D + 25 mmInsulation with Isover.

    SLGU, 100 mm insulationDamping in (dB)

    d1

    D for mediumProduct code nom nom L frequency (Hz)

    mm mm mm 125 250 500 1000 2000 4000 kg

    SLGU 80- 300 80 280 300 8 13 19 27 33 29 4

    80- 600 80 280 600 17 26 29 53 53 45 6

    80- 900 80 280 900 25 23 32 55 56 46 9

    80-1000 80 280 1000 24 27 33 55 58 47 10

    SLGU 100- 300 100 315 300 6 12 18 23 28 23 5

    100- 600 100 315 600 13 23 34 46 52 40 8

    100- 900 100 315 900 17 30 39 54 55 46 10

    100-1000 100 315 1000 19 36 39 56 51 40 11

    SLGU 125- 300 125 315 300 6 10 15 19 23 18 5

    125- 600 125 315 600 11 20 30 40 45 30 8

    125- 900 125 315 900 15 27 38 56 62 39 11

    125-1000 125 315 1000 16 31 35 48 51 30 11

    125-1200 125 315 1200 15 34 38 56 59 45 13

    SLGU 160- 300 160 355 300 4 8 12 16 21 14 6

    160- 600 160 355 600 9 16 28 33 37 21 9

    160- 900 160 355 900 11 24 35 49 51 27 12

    160-1000 160 355 1000 12 25 38 54 54 29 14

    160-1200 160 355 1200 12 29 41 56 57 33 16

    SLGU 200- 600 200 400 600 6 12 22 28 28 18 12

    200- 900 200 400 900 8 18 28 40 37 23 17

    200-1000 200 400 1000 9 21 29 44 38 25 19

    200-1200 200 400 1200 10 25 33 50 42 27 23

    SLGU 250- 600 250 450 600 5 12 20 24 23 14 14

    250- 900 250 450 900 6 17 30 34 28 17 20

    250-1000 250 450 1000 7 18 31 36 30 18 20

    250-1200 250 450 1200 9 22 35 39 33 20 26

    SLGU 315- 600 315 500 600 4 8 14 17 14 12 16

    315- 900 315 500 900 4 12 21 26 19 15 22

    315-1000 315 500 1000 5 13 23 29 20 16 26

    315-1200 315 500 1200 7 15 28 35 24 18 29

    SLGU 400- 900 400 600 900 5 12 19 22 18 13 29

    400-1000 400 600 1000 5 13 22 24 20 14 31

    400-1200 400 600 1200 7 16 22 29 22 15 36

    400-1500 400 600 1500 9 20 32 35 24 17 43

  • 8/10/2019 Lindab Marine Catalogue