457 ISP ’12 Lightning Surge Protectors Protecting sensor, signal, power and communication lines Designed for the rugged industrial environment. Products range from the standard factory floor signals such as 4 – 20mA, thermocouple, RTD and strain gauge to filtering and protecting the AC Power and communication lines in instrument panels.

Upload: others

Post on 17-Feb-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

  • 457ISP ’12

    Lightning Surge Protectors

    Protecting sensor, signal, power and communication lines

    Designed for the rugged industrial environment. Products range from the standard factory floor signals such as 4 – 20mA, thermocouple, RTD and strain gauge to filtering and protecting the AC Power and communication lines in instrument panels.

  • Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

    J

    458

    458 Lightning Surge Protectors for Electronics Equipment M-RESTER

    What is Lightning? How to Protect Instruments?

    Entry pathway of lightning surgeDue to the online application of modern electronic systems, there are multiple interfacing parts to the outside for an instru-ment. One of such interface parts is signal cable and the other one is power cable. These cables pulled from the outside can be perfect entry pathways for the lightning surge.

    The effects of induced surge on a connected device will be more severe when the connected cable is longer and the device is located closer to the place where the actual lightning strikes. Even lightning rods with minimal cable length do not always protect as they are hoped.

    The effect of lightning surges depends upon the cable loca-tion and its environment. Surge protectors installed in those paths absorb and eliminate the high voltage impulse energy and protect the electric instrument from damage (Figure 1).

    Breaking mode of electrical instrumentSurge voltage generated between a cable and the ground might reach several tens of thousands of volt, however, lightning occurs at a voltage typically five thousand volts between the cable and the ground, while it induces several hundred volts between lines.

    When analyzing breaking condition of the instrument, it is often broken by this line voltage. We call it ‘interline breakdown’. Characteristics of interline breakdown is that semiconductor parts near the entry point of lightning surge breaks.

    Also, breaking mode between the cable and the ground is called ‘discharge breakdown’. Because the lightning surge voltage is very high against that of the ground, an arc discharge is generated between an electronic circuit and a grounded enclosure. Characteristics of discharge breakdown is that weak part of insulation between the circuit and enclosure breaks down.

    M-System’s surge protectors keep the surge voltage level at which instrument does not get damaged and prevent interline breakdown and discharge breakdown.

    Interline breakdown (V1)This occurs when the surge voltage between cables is directly applied to the electronic components in the instrument. Usually, only these components that are located near the termination of the cable where the surge entered are destroyed.

    Discharge breakdown (V2, V3)Lightning surges cause a very high potential (voltage) difference be-tween two conductors and the ground, and a discharge occurs between some part of an electronic circuit and those electrically connected to the ground, such as metal housings. Electronic components become damaged because some of the discharge current flows through the electronic circuit (Figure 2).

    GG G

    signalline system

    powerline

    surgeprotector

    Figure 1ground

    G

    ground

    instrumentlightning surge

    cable

    V2

    V1

    +

    V3

    Figure 2

    Signal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Standard Signal Line & Pulse Use

    Lightning Surge Protectors

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

  • Lightning Surge Protectors for Electronics Equipment M-RESTER

    Specifications are subject to change without notice.ISP ’12

    J

    459

    459

    What is Lightning? How to Protect Instruments?

    Fundamentals of surge absorbingInduced lightning is a current source which tries to flow the current. This current is the lightning surge current. When current does not flow smoothly, it generates high voltage and forces to let the current flow. The high voltage generated at that time is lightning surge voltage.

    Now, let us explain the fundamentals of lightning surge protector. Here we explain them with an example of a most commonly used model, the MDP-24-1. The diagram below is a simplified circuit of the MDP-24-1. On the cable, lightning surge voltage V1-V3 is generated to let the current flow. We call V1, interline surge voltage, and V2 and V3, line to ground surge voltage.

    The surge protector absorbs V1 at the discharge element SA1 and V2 and V3 in SA2 and SA3. SA1-SA3 can be considered as voltage-dependant switches. When the voltage is high, an arc is discharged and they suppress the arc discharge of V1-V3 around 30V. It is important to limit the surge voltage as low as possible. Especially, V1, which is applied directly to the protected instrument, is eliminated by the discharge element SA1 and the voltage limiting element D1.

    SA can bypass high current, however, its firing potential is high and the setting voltage varies widely. In order to compensate these disadvantages, it is combined with D1 of which firing potential is low and the setting voltage does not vary much and suppresses the surge voltage to a low level. D1, which does not tolerate high current, is also protected by R1 which limits the surge current (Figure 3).

    The discharge element and the voltage limiting element together are called the surge absorber element. Since there is no one ideal surge absorber element, i.e. small size, small setting voltage variation, fast response time, high discharge withstand current rating, no failure in shortcircuit mode, the surge absorber circuit is designed with combinations of components to bring out their good characteristics.

    Which surge protector do you choose?Surge protectors for signal lineM-System’s surge protectors are classified according to sensor/signal types, such as standard 4–20 mA signal, RTD, ther-mocouple, potentiometer, strain gauge and pulse generating device. We also have those specific for various field networks such as RS-485/RS-422, Ethernet, DeviceNet, PROFIBUS, LONWORKS and FOUNDATION Fieldbus.

    [Example]

    A two-wire transmitter in general transmits 4 to 20mA DC output signal, powered by 24V DC power source on the same loop.

    Choose the lightning surge protector for standard signal (ex. MDP-24-1). Both transmitter and control room instrument incorporate electric circuits. Therefore, surge protectors are needed at the both side.

    In case of RTD, choose the lightning surge protector for RTD use (ex. MDP-RB). Even though the sensor has no electric circuit, a surge protector should be connected at the detection side in order to prevent the platinum resistance probe from breaking, in addition to the transmitter side.

    Surge protectors for power lineMaximum load current up to 200 A is selectable. Single-phase/two-wire, single-phase/three-wire, three-phase/three-wire and DC power supply systems are selectable. Choose one based on the load current and the number of phase.

    surgeR1

    cable resistance

    SA1V1 V3

    V2 SA2 SA3

    D1

    G

    protecteddevice

    electriccircuitry

    +

    P

    P

    G

    S

    S

    Figure 3ground

    Signal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Lightning Surge Protectors

    Standard Signal Line & Pulse Use

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

  • Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

    J

    460

    460 Lightning Surge Protectors for Electronics EquipmentM-RESTERSignal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Standard Signal Line & Pulse Use

    Lightning Surge Protectors

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    M-System Lightning Surge Protectors absorb only the lightning surges with no interruption of the instrumentation signal.

    ◆ Protects sensor, signal and power lines

    ◆ Can be removed and tested without disconnecting wires (MDP series)

    ◆ Superior protection and selection across a wide range of applications including:

    Frequency generating devicesTelemetering devicesRS-485 / RS-422, Ethernet, DeviceNet, PROFIBUS, LONWORKS, FOUNDATION FieldbusAC/DC Power supply lines (1 amp up to 30 amps)

    4–20mA & pulse signalThermocoupleRTDPotentiometerStrain gauge

    ■ Standard Signal Line & Pulse Use

    Model Function Page

    MD7AST Lightning Surge Protector for Standard Signal Line (ultra-slim; life monitor) P.462

    MDPA-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (life monitor) P.462

    MDPA-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (life monitor) P.462

    MDM2A-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (life monitor) P.462

    MDM2A-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (life monitor) P.462

    MD7ST Lightning Surge Protector for Standard Signal Line (ultra-slim) P.462

    MDP-24-1 Lightning Surge Protector for Standard Signal Line & Pulse Use P.462

    MDP-65-1 Lightning Surge Protector for Standard Signal Line & Pulse Use P.462

    MDK-24 Lightning Surge Protector for Standard Signal Line Use P.463

    MDJST Lightning Surge Protector for Standard Signal Use (fast response: 3 nsec.) P.463

    MMDHLightning Surge Protector for Standard Signal Line Use (high speed/high discharge current capacity)

    P.463

    MMD Lightning Surge Protector for Standard Signal Line Use (high discharge current capacity) ***

    MD72W Lightning Surge Protector for Two-wire Signal Loop (ultra-slim) P.463

    MD72WD Lightning Surge Protector for Two-wire Signal Loop (ultra-slim; 2 channels) P.463

    MD73W Lightning Surge Protector for Three-wire Signal Loop (ultra-slim) P.463

    MD6N-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464

    MD6N-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464

    MD6T-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464

    MD6T-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464

    MD6P-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464

    MD6P-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464

    ■ Sensor Use

    Model Function Page

    MD7TC Lightning Surge Protector for Thermocouple (ultra-slim) P.465

    MDP-TC Lightning Surge Protector for Thermocouple Use P.465MD7RB Lightning Surge Protector for RTD (ultra-slim) P.465MDP-RB Lightning Surge Protector for RTD Use P.465

    MD7PM Lightning Surge Protector for Potentiometer (ultra-slim) P.465

    MDP-PM Lightning Surge Protector for Potentiometer Use P.465

    MD7LC Lightning Surge Protector for Strain Gauge Use (ultra-slim) P.466

    MDP-LC Lightning Surge Protector for Strain Gauge Use P.466MDK-LC Lightning Surge Protector for Strain gauge Use P.466

    MD-LC2 Lightning Surge Protector for Strain gauge Use (6-wire remote sensing) P.466

    MDK-LV Lightning Surge Protector for Signal Line with Excitation Use P.466

    MD7JS Lightning Surge Protector for Self-Synch Use (ultra-slim) P.467

    MDP-JS Lightning Surge Protector for Self-Synch Use P.467

    MD7PL Lightning Surge Protector for Pulse Signal (ultra-slim) P.467

    MDP-SP Lightning Surge Protector for Low Frequency Use P.467

    MDR2 Lightning Surge Protector for Multi-channel Use (high discharge current capacity) P.467

    ■ Transmission Line Use

    Model Function Page

    MD74R Lightning Surge Protector for RS-485/RS-422 (ultra-slim) P.468

    MDP-4R Lightning Surge Protector for RS-485/RS-422 P.468

    MDW5-4R Lightning Surge Protector for RS-485/RS-422 (full-duplex) P.468

    MDW2A-4R Lightning Surge Protector for RS-485/RS-422 (life monitor) P.468

    MDCAT Lightning Surge Protector for Ethernet (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) P.468

    MDM5E-A Lightning Surge Protector for Ethernet (100 BASE-TX / 10 BASE-T) P.468

    SHSP 8-Port Ethernet Switch (with surge protector) P.469

    MD7AST,MDPA-24,MDPA-65,MDM2A-24,MDM2A-65,MD7ST,MDP-24-1,MDP-65-1,MDK-24,MDJST,MMDH,MMD,MD72W,MD72WD,MD73W,MD6N-24,MD6N-65,MD6T-24,MD6T-65,MD6P-

    24,MD6P-65,MD7TC,MDP-TC,MD7RB,MDP-RB,MD7PM,MDP-PM,MD7LC,MDP-LC,MDK-LC,MD-LC2,MDK-LV,MD7JS,MDP-JS,MD7PL,MDP-SP,MDR2,MD74R,MDP-4R,MDW5-

    4R,MDW2A-4R,MDCAT,MDM5E-A,SHSP,MD7PA,MDP-PA,MD7LWA,MDP-LWA,MD-DNM,MD-DNS,MD7FB,MDP-DM3,MDP-EC,MDP-MFA,MDP-FT,MD-INS,MD-TL,MDP-TL,MDA-

    TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA,MAAC,MMAJ,MMA,MMAH,MAX,MAH,MMH,MH-105A,MH-110A,MH-130A,MH-205A,MH-210A,MH-230A,MH-1201,MH-2201,MH-

    2203,MD7DP,MDP-D,MDHA,MDH,MAT2,MAKF,C-106A-1,A-33,MD7F,MD7G,MBS,CNB,BX-W1

  • Lightning Surge Protectors for Electronics Equipment M-RESTER

    Specifications are subject to change without notice.ISP ’12

    J

    461

    461Signal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Lightning Surge Protectors

    Standard Signal Line & Pulse Use

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    To find a product in the list with “***”, visit M-System Data Library.If you cannot find a product here, please contact: [email protected]

    Model Function Page

    MD7PA Lightning Surge Protector for PROFIBUS-PA (ultra-slim) P.469

    MDP-PA Lightning Surge Protector for PROFIBUS-PA P.469

    MD7LWA Lightning Surge Protector for LONWORKS (ultra-slim, FTT-10A) P.470

    MDP-LWA Lightning Surge Protector for LONWORKS (FTT-10A) P.470

    MD-DNM Lightning Surge Protector for DeviceNet (load capacity 8A) P.470

    MD-DNS Lightning Surge Protector for DeviceNet (load capacity 2A) P.470

    MD7FB Lightning Surge Protector for FOUNDATION Fieldbus (ultra-slim) P.470

    MDP-DM3 Lightning Surge Protector for MsysNet Use ***MDP-EC Lightning Surge Protector for EC-Cable Use ***

    MDP-MFA Lightning Surge Protector for Telemetering Use (50 bps) ***

    MDP-FT Lightning Surge Protector for Telemetering Use (3.4 kHz) ***

    MD-INS Lightning Surge Protector for ISDN Circuit Use ***

    MD-TL Lightning Surge Protector for Telecommunication Line Use ***

    MDP-TL Lightning Surge Protector for Telecommunication Line Use ***

    MDA-TL Lightning Surge Protector for Analog Telecom Line Use (life monitor) ***

    ■ Power Supply Use

    Model Function Page

    MD7AP Lightning Surge Protector for AC Power Supply (max. 3A; ultra-slim) P.470

    MDP-100 Lightning Surge Protector for AC/DC Power Supply Use (1A) P.470

    MDP-200 Lightning Surge Protector for AC/DC Power Supply Use (1A) P.470

    MA-100 Lightning Surge Protector for Power Supply (2A) P.471MA-200 Lightning Surge Protector for Power Supply (2A) P.471

    MAALightning Surge Protector for Power Supply Use (5A; high discharge current capacity; life monitor)

    P.471

    MAACLightning Surge Protector for Power Supply Use (5A; high discharge current capacity; life monitor/surge counter)

    P.471

    MMAJ Lightning Surge Protector for Power Supply Use (fast responce: 3 nsec.) P.471

    MMA Lightning Surge Protector for Power Supply Use (10A;high discharge current capacity) P.471

    MMAH Lightning Surge Protector for Power Supply Use (10A; high speed/high discharge current capacity) P.471

    MAX Lightning Surge Protector for Power Supply Use (5A; high discharge current capacity) P.472

    MAH Lightning Surge Protector for Power Supply Use (20A) ***

    MMH Lightning Surge Protector for Power Supply Use (10–30A; replaceable arrester module) P.472

    MH-105A Lightning Surge Protector for Power Supply Use (5A) ***

    MH-110A Lightning Surge Protector for Power Supply Use (10A) ***

    MH-130A Lightning Surge Protector for Power Supply Use (30A) ***

    Model Function Page

    MH-205A Lightning Surge Protector for Power Supply Use (5A) ***

    MH-210A Lightning Surge Protector for Power Supply Use (10A) ***

    MH-230A Lightning Surge Protector for Power Supply Use (30A) ***

    MH-1201 Lightning Surge Protector for Power Supply Use (200A) ***

    MH-2201 Lightning Surge Protector for Power Supply Use (200A) ***

    MH-2203 Lightning Surge Protector for Power Supply Use (200A) ***

    ■ DC Power Supply Use

    Model Function Page

    MD7DP Lightning Surge Protector for DC Power Supply (max. 1.2A; ultra-slim) P.472

    MDP-D Lightning Surge Protector for DC Power Supply Use P.472

    MDHA Lightning Surge Protector for Power Supply Use (DC power use; life monitor) P.472

    MDH Lightning Surge Protector for Power Supply Use (DC power use) P.472

    ■ One-port Surge Protector

    Model Function Page

    MAT2 Lightning Surge Protector for Three-phase Power Supply P.473

    MAKF One-port Surge Protector for Power Supply Use P.473

    ■ Accessories

    Model Function Page

    C-106A-1 M-RESTER Tester P.473A-33 DIN Rail Mounting Adaptor P.473MD7F Loop Disconnect Fuse ***MD7G Terminal Block For Grounding (ultra-slim) ***MBS Single Mount Adaptor ***CNB Wiring Bridge ***BX-W1 Outdoor Housing (weather-proof) P.473

  • Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

    J

    462

    462 Lightning Surge Protectors for Electronics Equipment M-RESTERSignal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Standard Signal Line & Pulse Use

    Lightning Surge Protectors

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    4–20mA & Pulse Signal, Ultra-slim Type

    Model MD7ST-24 MD7ST-60Max. Cont. Operat. Volt. (Uc) 30V 70V

    Voltage Protection Level (Up) 60V max. 115V max.

    Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)Nominal Current (IN) 250 mAInternal Resistance (Ω ±10%, per line)

    4.7 Ω w/o fuse7.5 Ω w/ fuse

    10 Ω w/o fuse12.5 Ω w/ fuse

    Test Standard IEC 61643-21 (Categories C1, C2, D1)

    4–20mA & Pulse Signal, Plug-in Type

    Model MDP-24-1 MDP-65-1Max. Cont. Operat. Volt. (Uc) 30V min. 70V min.

    Voltage Protection Level (Up) 40V max.@1kV (100A) 45V max.@2kV (1kA)80V max.@1kV (100A) 110V max.@2kV (1kA)

    Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mA

    Internal Resistance 20 Ω ±10% (incl. return)

    Test Standard IEC 61643-21 (Categories C1, C2)

    4–20mA & Pulse Signal, Ultra-slim Type, with Life Monitor

    Model MD7AST-24 MD7AST-60Max. Cont. Operat. Volt. (Uc) 30V 70V

    Voltage Protection Level (Up) 60V max. 115V max.

    Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)Nominal Current (IN) 250 mAInternal Resistance 4.7 Ω ±10% per line 10 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

    4–20mA & Pulse Signal, Plug-in Type, with Life Monitor

    Model MDPA-24 MDPA-65Max. Cont. Operat. Volt. (Uc) 30V min. 70V min.

    Voltage Protection Level (Up) 45V max.@1kV (100A) 50V max.@2kV (1kA)85V max.@1kV (100A) 100V max.@2kV (1kA)

    Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mAInternal Resistance 20 Ω ±10% (incl. return)Test Standard IEC 61643-21 (Categories C1, C2)

    4–20mA & Pulse Signal, Plug-in Type, with Life Monitor

    Model MDM2A-24 MDM2A-65Discharge Voltage 30V min. 70V min.Max. Surge Voltage 45V max. 85V max.Response Time 0.1 μsec. max.Discharge Current 5000A (8/20 μsec.)Max. Load Current 100 mAInternal Resistance Approx. 20 Ω (incl. return)Test Standard ----

    ■ Standard Signal Line & Pulse Use

    LIFEMONITOR

    MD7AST,MDPA-24,MDPA-65,MDM2A-24,MDM2A-65,MD7ST,MDP-24-1,MDP-65-1,

    LIFEMONITOR

    LIFEMONITOR

  • Lightning Surge Protectors for Electronics Equipment M-RESTER

    Specifications are subject to change without notice.ISP ’12

    J

    463

    463Signal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Lightning Surge Protectors

    Standard Signal Line & Pulse Use

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    Two-Wire Transmitter Loop, Ultra-slim Type

    Model MD72W-07 MD72W-16 MD72W-32 MD72W-55Max. Cont. Operat. Volt. (Uc) ±7V ±16V ±32V ±55VVoltage Protection Level (Up) 20V max. 30V max. 50V max. 80V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)Nominal Current (IN) 400 mA w/o fuse, 250 mA w/ fuseInternal Resistance (Ω ±20%, per line) 2.2 Ω w/o fuse, 4 Ω w/ fuse

    Test Standard IEC 61643-21 (Categories C1, C2, D1)

    Two-Wire Transmitter Loop, 2 channels, Ultra-slim Type

    Model MD72WD-07 MD72WD-16 MD72WD-32Max. Cont. Operat. Volt. (Uc) ±7V ±16V ±32VVoltage Protection Level (Up) 30V max. 45V max. 70V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)Nominal Current (IN) 250 mAInternal Resistance 4.7 Ω ±20% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

    4–20mA & Pulse Signal, High Speed, Plug-in Type

    Model MDJST-12 MDJST-24 MDJST-48Max. Cont. Operat. Volt. (Uc) ±18V ±36V ±60VVoltage Protection Level (Up) ±30V max. ±50V max. ±90V max.Response Time 3 nanosec. max.Max. Discharge Curr. (Imax) 20 kA (8/20 μs)Nominal Current (IN) 1AInternal Resistance 3Ω max.Test Standard IEC 61643-21 (Categories C1, C2)

    4–20mA & Pulse Signal, Low Profile Type

    Model MDK-24Discharge Voltage 30V min.Max. Surge Voltage 40V max.Response Time 0.1 μsec. max.Discharge Current 5000A (8/20 μsec.)Max. Load Current 100 mAInternal Resistance 20 Ω ±5%Test Standard ----

    4–20mA & Pulse Signal, High Speed, High Discharge Current Capacity

    Model MMDH-24Discharge Voltage ±40V min.Max. Surge Voltage ±50V max.Response Time 4 nanosec.Discharge Current 20000A (8/20 μsec.)Max. Load Current 0.1 A

    Internal Resistance ≤0.4 Ω (incl. return)

    Test Standard ----

    Three-Wire Transmitter Loop, Ultra-slim Type

    Model MD73WMax. Cont. Operat. Volt. (Uc) ±32VVoltage Protection Level (Up) ±60V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)Nominal Current (IN) 400 mAInternal Resistance ≤2.2 Ω ±20% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

    ■ Standard Signal Line & Pulse Use

    MDK-24,MDJST,MMDH,MD72W,MD72WD,MD73W,

  • Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

    J

    464

    464 Lightning Surge Protectors for Electronics Equipment M-RESTERSignal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Standard Signal Line & Pulse Use

    Lightning Surge Protectors

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    4–20mA & Pulse Signal, Conduit Mount, Weather-Proof (Terminal Block Connection Type)

    Model MD6T-24 MD6T-65Discharge Voltage 30V min. 70V min.Max. Surge Voltage 40V max. 100V max.Response Time 4 nanosec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 100 mAInternal Resistance Approx. 22 Ω (incl. return)

    Approvals

    • FM intrinsically safe• CENELEC intrinsically

    safe (ATEX)• CENELEC flameproof

    (ATEX)• FM nonincendive

    • CENELEC flameproof (ATEX)

    4–20mA & Pulse Signal, Conduit Mount, Weather-Proof (Leadwire Connection, Pipe Nipple Type)

    Model MD6N-24 MD6N-65Discharge Voltage 30V min. 70V min.Max. Surge Voltage 40V max. 100V max.Response Time 4 nanosec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 100 mAInternal Resistance Approx. 22 Ω (incl. return)

    Approvals

    • FM intrinsically safe• CENELEC intrinsically

    safe (ATEX)• FM explosion-proof• CENELEC flameproof

    (ATEX)• FM nonincendive

    • FM explosion-proof• CENELEC flameproof

    (ATEX)

    4–20mA & Pulse Signal, Conduit Mount, Weather-Proof (Leadwire Connection, Stopping Plug Type)

    Model MD6P-24 MD6P-65Discharge Voltage 30V min. 70V min.Max. Surge Voltage 40V max. 100V max.Response Time 4 nanosec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 100 mAInternal Resistance Approx. 22 Ω (incl. return)

    Approvals

    • FM intrinsically safe• CENELEC intrinsically

    safe (ATEX)• FM explosion-proof• CENELEC flameproof

    (ATEX)• FM nonincendive

    • FM explosion-proof• CENELEC flameproof

    (ATEX)

    ■ Standard Signal Line & Pulse Use

    MD6N-24,MD6N-65,MD6T-24,MD6T-65,MD6P-24,MD6P-65,

  • Lightning Surge Protectors for Electronics Equipment M-RESTER

    Specifications are subject to change without notice.ISP ’12

    J

    465

    465Signal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Lightning Surge Protectors

    Standard Signal Line & Pulse Use

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    Thermocouple, Ultra-slim Type

    Model MD7TCMax. Cont. Operat. Volt. (Uc) 7.5VVoltage Protection Level (Up) 25V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 100 mAInternal Resistance 4.7 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

    Thermocouple, Plug-in Type

    Model MDP-TCMax. Cont. Operat. Volt. (Uc) 7.5V min.Voltage Protection Level (Up) 16V max.@1kV (100A), 20V max.@2kV (1kA)Response Time 0.1 μsec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mAInternal Resistance 20 Ω ±10% (incl. return)Test Standard IEC 61643-21 (Categories C1, C2)

    RTD, Ultra-slim Type

    Model MD7RBMax. Cont. Operat. Volt. (Uc) ±3V

    Voltage Protection Level (Up) ±25V max.

    Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 100 mAInternal Resistance 5.12 Ω ±0.3%, ±30 ppm/°C per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

    RTD, Plug-in Type

    Model MDP-RBMax. Cont. Operat. Volt. (Uc) ±6V min. (B to C), ±3V min. (B or C to A)

    Voltage Protection Level (Up) ±40V max.@2kV (1kA) (2 to 3), ±25V max.@2kV (1kA) (2 or 3 to 1)Response Time 0.1 μsec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mAInternal Resistance 10 Ω ±0.1%, 30 ppm/°CTest Standard IEC 61643-21 (Categories C1, C2)

    Potentiometer, Ultra-slim Type

    Model MD7PMMax. Cont. Operat. Volt. (Uc) 7.5VVoltage Protection Level (Up) 25V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 100 mAInternal Resistance 4.7 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

    Potentiometer, Plug-in Type

    Model MDP-PMMax. Cont. Operat. Volt. (Uc) 7.5V min.Voltage Protection Level (Up) 16V max.@1kV (100A), 25V max.@2kV (1kA)Response Time 0.1 μsec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mAInternal Resistance 10 Ω ±0.1%, 30 ppm/°CTest Standard IEC 61643-21 (Categories C1, C2)

    ■ Sensor Use

    MD7TC,MDP-TC,MD7RB,MDP-RB,MD7PM,MDP-PM,

  • Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

    J

    466

    466 Lightning Surge Protectors for Electronics Equipment M-RESTERSignal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Standard Signal Line & Pulse Use

    Lightning Surge Protectors

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    Strain Gauge, Ultra-slim Type

    Model MD7LC-0* MD7LC-1

    Max. Cont. Operat. Volt. (Uc)Line Side ±0.2VExc. Side 15V

    Voltage Protection Level (Up)Line Side ±15V max. @0.2kV (1.2 / 50 μs) ±40V max. @6kV (1.2 / 50 μs)Exc. Side 30V max. @0.2kV (1.2 / 50 μs) 50V max. @6kV (1.2 / 50 μs)

    Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 100A (8/20 μsec.) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) ---- 250 mAInternal Resistance ---- 1.5 Ω ±10% per lineTest Standard ---- IEC 61643-21 (Categories C1, C2, D1)

    Strain Gauge, Plug-in Type

    Model MDP-LCMax. Cont. Operat. Volt. (Uc)

    Line Side ±0.3V min.Exc. Side 15V min.

    Voltage Protection Level (Up)

    Line Side ±15V max.Exc. Side 30V max.

    Response Time 5 nanosec. max.Max. Discharge Curr. (Imax)

    Line Side 100A (8/20 μsec.), 25A (10/1000 μsec.)Exc. Side 50A (8/20 μsec.), 25A (10/1000 μsec.)

    Test Standard IEC 61643-21 (Category C3)

    Strain Gauge, 6-wire Remote Sensing

    Model MD-LC2

    Discharge VoltageLine Side ±0.3V min.Exc. Side 15V min.

    Max. Surge Voltage

    Line Side ±20V max.Exc. Side 40V max.

    Response Time 4 nanosec. max.Discharge Current 5000A (8/20 μsec.)Test Standard ----

    Strain Gauge, Low Profile Type

    Model MDK-LC

    Discharge VoltageLine Side ±0.3V min.Exc. Side 15V min.

    Max. Surge Voltage

    Line Side ±15V max.Exc. Side 30V max.

    Response Time 5 nanosec. max.

    Discharge CurrentLine Side 100A (8/20 μsec.)Exc. Side 50A (8/20 μsec.)

    Test Standard ----

    Signal Line with Excitation, Low Profile Type

    Model MDK-LV

    Discharge VoltageLine Side 10V min.Exc. Side 30V min.

    Max. Surge Voltage

    Line Side 20V max.Exc. Side 40V max.

    Response Time 0.1 μsec. max.Discharge Current 5000A (8/20 μsec.)Test Standard ----

    ■ Sensor Use

    * No CE marking.

    MD7LC,MDP-LC,MDK-LC,MD-LC2,MDK-LV,

  • Lightning Surge Protectors for Electronics Equipment M-RESTER

    Specifications are subject to change without notice.ISP ’12

    J

    467

    467Signal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Lightning Surge Protectors

    Standard Signal Line & Pulse Use

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    Self-Synch, Ultra-slim Type

    Model MD7JSMax. Cont. Operat. Volt. (Uc) ±130V

    Voltage Protection Level (Up) ±450V max.

    Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 500 mAInternal Resistance 2 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

    Self-Synch, Plug-in Type

    Model MDP-JSMax. Cont. Operat. Volt. (Uc) ±170V min. (A to B to C)

    Voltage Protection Level (Up) ±350V max.@1kV (100A) (1 to 2 to 3), ±450V max.@2kV (1kA) (1 to 2 to 3)Response Time 0.1 μsec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 500 mAInternal Resistance Approx. 2 Ω per wireTest Standard IEC 61643-21 (Categories C1, C2)

    2-Point Pulse with Common Negative, Ultra-slim Type

    Model MD7PL-P Positive (PNP)

    MD7PL-N Negative (NPN)

    Max. Cont. Operat. Volt. (Uc) -30V +30VVoltage Protection Level (Up) -50V max. +50V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 100 mAInternal Resistance 11 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

    Low Frequency Pulse, Plug-in Type

    Model MDP-SP

    Max. Cont. Operat. Volt. (Uc) 14V min.Voltage Protection Level (Up) 30V max.@1kV (100A), 30V max.@2kV (1kA)Response Time 0.1 μsec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 50 mAInternal Resistance 10 Ω ±10%Test Standard IEC 61643-21 (Categories C1, C2)

    High Discharge, 8-point Pulse Signal, Terminal Board Type

    Model MDR2-8NY Negative (NPN)

    MDR2-8NA Negative (NPN) with

    Leakage current Indicator

    MDR2-8PY Positive (PNP)

    MDR2-8PA Positive (PNP) with

    Leakage current IndicatorMax. Cont. Operat. Volt. (Uc) +30V -30VVoltage Protection Level (Up) @4kV / 2kA (1.2 / 50 μsec.) +50V +60V -50V -60VResponse Time 4 nanosec. max.Max. Discharge Curr. (Imax) 10kANominal Current (IN) 150 mAInternal Resistance 22 Ω ±20%Test Standard IEC 61643-21 (Categories C1, C2)

    ■ Sensor Use

    MD7JS,MDP-JS,MD7PL,MDP-SP,MDR2,

  • Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

    J

    468

    468 Lightning Surge Protectors for Electronics Equipment M-RESTERSignal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Standard Signal Line & Pulse Use

    Lightning Surge Protectors

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    RS-485/RS-422, Ultra-slim Type

    Model MD74RMax. Cont. Operat. Volt. (Uc) ±5VVoltage Protection Level (Up) ±25V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 100 mAInternal Resistance 2 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

    RS-485/RS-422, Plug-in Type

    Model MDP-4RMax. Cont. Operat. Volt. (Uc) ±5V min. (B to C)Voltage Protection Level (Up) ±20V max. (2 to 3)Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mAInternal Resistance Approx. 4.5 Ω (incl. return)Test Standard IEC 61643-21 (Categories C1, C2)

    RS-485/RS-422, Plug-in Type with Life Monitor

    Model MDW2A-4RDischarge Voltage ±5V min. (7 to 8)Max. Surge Voltage ±25V max. (4 to 5)Response Time 4 nanosec. max.Discharge Current 5000A (8/20 μsec.)Max. Load Current 100 mAInternal Resistance Approx. 5 Ω (incl. return)Test Standard ----

    RS-485/RS-422, Full-duplex

    Model MDW5-4RDischarge Voltage ±5V min. (6 to 7, 8 to 9)Max. Surge Voltage ±25V max. (1 to 2, 3 to 4)Response Time 4 nanosec. max.Discharge Current 10kA (8/20 μsec.)Max. Load Current 100 mAInternal Resistance Approx. 4 Ω (incl. return)Test Standard ----

    Ethernet, 100 BASE-TX / 10 BASE-T

    Model MDM5E-ADischarge Voltage ±6V min.Max. Surge Voltage 38V max.Response Time 4 nanosec. max.Discharge Current 500A (8/20 μsec.)Series Resistance Approx. 0 ΩImpulse durability Category c1Test Standard IEC 61643-21 : 2000

    Ethernet, PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T

    Model MDCAT-5E (CAT5e) MDCAT-6 (CAT6)Max. Cont. Operat. Volt. (Uc) ±6V ±3.3VVoltage Protection Level (Up) ±15V max. @2kV ±10V max. @2kVResponse Time 4 nanosec. max.Max. Discharge Curr. (Imax) 100ANominal Current (IN) 1AInternal Resistance Approx. 0 ΩTest Standard IEC 61643-21 (Categories C1, C2)

    ■ Transmission Line Use

    MD74R,MDP-4R,MDW5-4R,MDW2A-4R,MDCAT,MDM5E-A,

    LIFEMONITOR

  • Lightning Surge Protectors for Electronics Equipment M-RESTER

    Specifications are subject to change without notice.ISP ’12

    J

    469

    469Signal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Lightning Surge Protectors

    Standard Signal Line & Pulse Use

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    PROFIBUS-PA, Ultra-slim Type

    Model MD7PAMax. Cont. Operat. Volt. (Uc) ±32VVoltage Protection Level (Up) ±60V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 400 mAInternal Resistance 1.5 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

    PROFIBUS-PA, Plug-in Type

    Model MDP-PAMax. Cont. Operat. Volt. (Uc) 27V min.Voltage Protection Level (Up) ±60V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 500 mAInternal Resistance ≤3.3 Ω (incl. return)Test Standard IEC 61643-21 (Categories C1, C2)

    ■ Transmission Line Use

    8-Port Ethernet Switch (with surge protector)

    Surge protector function for each port ◆ Protects Ethernet devices from surges

    entering through LAN cables

    ◆ Surge protector life monitor function with LED and contact output alarm

    ◆ Data transfer rate can be fixedModel: SHSP

    ■ LAN PORT SPECIFICATIONSStandards IEEE 802.3, IEEE 802.3u, IEEE 802.3xNumber of ports 8; All ports support AUTO-MDIX*

    Data transfer rate10 Mbps (10 BASE-T), 100 Mbps (100 BASE-TX); Supports Auto-Negotiation

    Cable 10 BASE-T (STP cable, category 5)100 BASE-TX (STP cable, category 5e)Maximum segment length 100 metersSwitching Store & Forward

    Flow controlFull duplex PAUSE FramesHalf duplex Back pressure

    Buffer 64 KBMAC address table 1024

    ■ SURGE PROTECTOR PERFORMANCECompliant standard EN61000-4-5 level X Between ports 1kV (combination waveform)** Port to G 10kV (combination waveform) FG (shield) to G 15kV (combination waveform)***

    Voltage protection level

    Port to FG or G 160V min.Between each port 160V min.

    FG to G 160V min. (with the shortcircuit bar removed)

    SHSP,MD7PA,MDP-PA,

    LIFEMONITOR

    * Automatically sensing cable type, straight-through or cross-over.** RJ-45 connector contact is out of the scope of this protection. Using twisted-pair (STP) LAN cable is effective to reduce risk of fusing contact.*** With the shortcircuit bar

  • Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

    J

    470

    470 Lightning Surge Protectors for Electronics Equipment M-RESTERSignal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Standard Signal Line & Pulse Use

    Lightning Surge Protectors

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    1A Load Rating, Plug-in Type

    Model MDP-100 MDP-200Max. Line Volt. (Uc) 120V AC 250V ACVoltage Protection Level (Up) 400V max. 800V max.Response Time 0.1 μsec. max.Max. Discharge Curr. (Imax) 1000A (8/20 μsec.)Nominal Current (IN) 1AInternal Resistance ≤0.4 Ω (incl. return)Test Standard IEC 61643-1 (Class III)

    3A Load Rating, Ultra-slim Type

    Model MD7AP-100 MD7AP-200Max. Cont. Operat. Volt. (Uc) 140V AC 275V ACVoltage Protection Level (Up) ±550V max. ±850V max.Response Time 20 nanosec. max.Max. Discharge Curr. (Imax) 10kA (8/20 μsec.)Nominal Current (IN) 3ATest Standard IEC 61643-21 (Categories C1, C2)

    ■ Power Supply Use

    ■ Transmission Line Use

    DeviceNet

    Model MD-DNM MD-DNS

    Discharge VoltageLine Side ±5V min.Exc. Side 26V min.

    Max. Surge Voltage

    Line Side ±15V max.Exc. Side 120V max.

    Response Time 0.1 μsec. max.

    Discharge CurrentLine Side

    1500A Exc. Side

    Load Capacity 8A 2ATest Standard ----

    FOUNDATION Fieldbus, Ultra-slim Type

    Model MD7FBMax. Cont. Operat. Volt. (Uc) ±32VVoltage Protection Level (Up) ±60V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 400 mAInternal Resistance 1.5 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

    LONWORKS (FTT-10A), Ultra-slim Type

    Model MD7LWAMax. Cont. Operat. Volt. (Uc) ±1.5V min.Voltage Protection Level (Up) ±30V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 100 mAInternal Resistance ≤3.3 Ω (incl. return)Test Standard IEC 61643-21 (Categories C1, C2, D1)

    LONWORKS (FTT-10A), Plug-in Type

    Model MDP-LWAMax. Cont. Operat. Volt. (Uc) ±1.5V min.Voltage Protection Level (Up) ±40V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mAInternal Resistance ≤3.3 Ω (incl. return)Test Standard IEC 61643-21 (Categories C1, C2)

    MD7LWA,MDP-LWA,MD-DNM,MD-DNS,MD7FB,MD7AP,MDP-100,MDP-200,

  • Lightning Surge Protectors for Electronics Equipment M-RESTER

    Specifications are subject to change without notice.ISP ’12

    J

    471

    471Signal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Lightning Surge Protectors

    Standard Signal Line & Pulse Use

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    2A Load Rating, Plug-in Type

    Model MA-100 MA-200Discharge Voltage 190V min. 410V min.Max. Surge Voltage 350V max. 700V max.Response Time 0.1 μsec. max.Discharge Current 1000A (8/20 μsec.)Max. Load Current 2AVoltage Drop ≤2V (50/60Hz)Test Standard ----

    5A Load Rating, with Life Monitor

    Model MAA-100 MAA-200Discharge Voltage 190V min. 410V min.Max. Surge Voltage 380V max. 700V max.Response Time 0.01 μsec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 5AInternal Resistance ≤0.5 Ω (incl. return)Test Standard ----

    5A Load Rating, with Life Monitor / Surge Counter

    Model MAAC-100 MAAC-200Discharge Voltage 190V min. 410V min.Max. Surge Voltage 400V max. 750V max.Response Time 0.01 μsec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 5AInternal Resistance ≤0.5 Ω (incl. return)Test Standard ----

    10A/20A/30A Load Rating, Wall-mounted, High Speed, High Discharge Current Capacity

    Model MMAJ-100 MMAJ-200Max. Cont. Operat. Volt. (Uc) 132V AC 264V ACVoltage Protection Level (Up) 900V max. 1500V max.Response Time 3 nanosec.Max. Discharge Curr. (Imax) 10kA, 20kAMax. Load Current 10A, 20A, 30ATest Standard IEC 61643-1 (Class II, III)

    10A Load Rating, Wall-mounted, High Speed, High Discharge Current Capacity

    Model MMAH-100 MMAH-200Discharge Voltage 190V min. 410V min.Max. Surge Voltage 400V max 750V max.Response Time 4 nanosec.Discharge Current 20000A (8/20 μsec.)Max. Load Current 10AInternal Resistance ≤0.5 Ω (incl. return)Test Standard ----

    10A Load Rating, Wall-mounted

    Model MMA-100 MMA-200Discharge Voltage 190V min. 410V min.Max. Surge Voltage 350V max 700V max.Response Time 0.01 μsec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 10AInternal Resistance ≤0.5 Ω (incl. return)Test Standard ----

    ■ Power Supply Use

    LIFEMONITOR

    MA-100,MA-200,MAA,MAAC,MMAJ,MMA,MMAH,

    LIFEMONITOR

  • Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

    J

    472

    472 Lightning Surge Protectors for Electronics Equipment M-RESTERSignal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Standard Signal Line & Pulse Use

    Lightning Surge Protectors

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    DC Power Supply Line, 1.2A Load Rating, Ultra-slim Type

    Model MD7DP-12 MD7DP-24Max. Cont. Operat. Volt. (Uc) 14V 27VVoltage Protection Level (Up) ±150V max. ±170V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 1.2AInternal Resistance ≤0.8 Ω (incl. return)Test Standard IEC 61643-21 (Categories C1, C2, D1)

    DC Power Supply Line, 1A Load Rating, Plug-in Type

    Model MDP-D12 MDP-D24Max. Cont. Operat. Volt. (Uc) 14V min. 30V min.Voltage Protection Level (Up) 20V max. 40V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 1AInternal Resistance ≤0.6 Ω (incl. return)Test Standard IEC 61643-1 (Class III)

    DC Power Supply Line, 5A Load Rating, Plug-in Type

    Model MDH-12 MDH-24 MDH-48Discharge Voltage 24V min. 50V min. 88V min.Max. Surge Voltage 70V max. 140V max. 210V max.Response Time 0.1 μsec. max.Discharge Current 2000A (8/20 μsec.)Max. Load Current 5AInternal Voltage Drop ≤1VTest Standard ----

    DC Power Supply Line, 5A Load Rating, with Life Monitor

    Model MDHA-12 MDHA-24Discharge Voltage ±15V min. ±30V min.Max. Surge Voltage ±80V max. ±120V max.Response Time 4 nanosec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 5AInternal Resistance ≤0.2 Ω (incl. return)Test Standard ----

    LIFEMONITOR

    5A Load Rating, Replaceable Surge Absorber

    Model MAX-100 MAX-200Discharge Voltage 190V min. 410V min.Max. Surge Voltage 350V max. 700V max.Response Time 0.01 μsec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 5AInternal Resistance ≤0.5 Ω (incl. return)Test Standard ----

    Medium Capacity 10A, 30A, Replaceable Surge Absorber

    Model MMH-110 MMH-130 MMH-210 MMH-230Discharge Voltage 130V min. 285V min.Max. Surge Voltage 350V max. 700V max.Response Time 0.01 μsec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 10A 30A 10A 30AVoltage Drop ≤1V (50/60Hz)Test Standard ----

    ■ Power Supply Use

    ■ DC Power Supply Use

    MAX,MMH,MD7DP,MDP-D,MDHA,MDH,

  • Lightning Surge Protectors for Electronics Equipment M-RESTER

    Specifications are subject to change without notice.ISP ’12

    J

    473

    473Signal Conditioners

    Two-wire Signal Conditioners

    Power Transducers

    Indicators

    Limit Alarms

    Gateway,Remote I/O

    Paperless RecordingSystem

    PC Recorder

    Electric Actuators& Position Sensors

    Lightning Surge Protectors

    Lightning Surge ProtectorsM-RESTER

    Lightning Surge Protectors

    Standard Signal Line & Pulse Use

    Sensor Use

    Transmission Line Use

    Power Supply Use

    DC Power Supply UseOne-port Surge Protector

    Accessories

    Three-phase Power Supply

    Model MAT2-240 MAT2-440Max. Cont. Operat. Volt. (Uc) 240V AC 440V ACVoltage Protection Level (Up) 1500V 2500VResponse Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 40kA (8/20 μsec.)Nominal Current (IN) 10kA (8/20 μsec.), 20kA (8/20 μsec.)Test Standard IEC 61643-1 (Class II)

    One-port Surge Protector

    Model MAKF-120 MAKF-240 MAKF-280 MAKF-400 MAKF-480Uc (AC) 150V 275V 320V 440V 530VDischarge Voltage 250V min. 420V min. 460V min. 670V min. 820V min.

    [email protected] (8/20ms) 600V max. 1000V max. 1100V max. 1500V max. 1800V [email protected] (8/20ms) 650V max. 1100V max. 1200V max. 1700V max. 2100V max.

    Response Time 20 nanosec. max.Max. Discharge Curr. 20kA × twice (8/20 μsec.)Test Standard ----

    ■ One-port Surge Protector

    ■ Accessories

    M-RESTER Testermodel: C-106A-1

    DIN Rail Mounting Adaptormodel: A-33

    Outdoor Housing (weather-proof) model: BX-W1

    Connected in parallel between the power and ground lines regardless of load current

    Connected in parallel between the power and ground lines regardless of load current

    MAT2,MAKF,C-106A-1,A-33,BX-W1

    ◆ Applicable to single phase 2/3-wire and three-phase 3/4- wire system.

    ◆ Degraded head element is automatically sepa-rated from the power lines by the incorporated thermal breaker, and the LED lamp (turns off) and the relay contact alerts the failure status.

    ◆ Thermal breaker ensures degraded head element to be automatically separated from the power lines to prevent overheating.

    ◆ Head-base connection is keyed so that only a head element of correct line voltage can be mounted.