Page 1: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Lighting up the Middle East since 1991

www.misterlight.com

Cables & AccessoriesMRL_8

Head OfficeTel: +971 4 296 3636Fax: +971 4 296 3646Email: [email protected] Mamzar, Dubai, U.A.E

Showroom – DubaiTel: +971 4 227 6061 (10 lines)Off: +971 4 224 7482Fax: +971 4 227 5179Email: [email protected]. Box: 55331Deira, Dubai, U.A.E

WarehouseTel: +971 4 333 7686Fax: +971 4 333 7808Email: [email protected] Aweer, Dubai, U.A.E

Showroom – Abu DhabiTel: +971 2 550 8111Fax: +971 2 550 8108P.O. Box: 45937Musaffah, Abu Dhabi, U.A.E

Misterlight Electrical Trading LLC

Page 2: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

CONTENTSAbout US 05Vision, Mission & Quality Policy 07International Standards & Approvals 08Application Fields 09Product Index 10

Page 3: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Misterlight is an ISO 9001:2008 certified company, established in 1991, supplying specialized cables and electrical accessories to clients across the UAE, as well as the GCC. We offer our clients the widest range of products for applications in different industrial sectors, including high profile leisure, commercial, industrial and residential applications. We help create a safe, secure and energy efficient society by defining a unified business strategy that aligns our internal management and activities to meet our stakeholders’ expectations.

All our company personnel assist on customer calls and marketing activities, enabling us to become partners to our clients. We believe in creating customers for life. We’re proud to have retained a small business environment, with customer relationships being our top priority.

About us

04 05PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 4: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

06 07

VISIONTo be a market leader in the supply of specializedelectrical cables and accessories globally, thus ensuring long term customer relationships through operational excellence and excellent customer referral.

MISSIONTo ensure the longevity of our company through recurring and referral business achieved by customer satisfaction in all aspects including timeliness, customer attention to detail and service-minded attitudes, by maintaining the highest levels of professionalism, integrity, honesty and fairness in our relationships with our suppliers, subcontractors, professional associates and clients.

QUALITY POLICYWe are committed to delighting our customers by providing superior electrical products with the highest degree of punctuality, operational excellence and professional project management.

This we shall achieve by:

• Ensuring continual improvements in our business operations. • Providing a growth oriented work environment to our employees. • Establishing and maintaining a symbiotic relationship with all the stakeholders. • Complying with all applicable regulatory and statutory requirements.

PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 5: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

08

APPLICATION FIELDS

09

Defence Systems• Single and multi-core cables low fire hazard type (self-extinguishing, low smoke, hazardous and corrosive gases generation cables)• Data transmission cables

Off-Shore Plants• Underwater cables, watertight• Single cables for underwater use• Cables for cathodic protection plants

Lighting Systems• High temperature Single and multi-core cables for halogen lamps

Automotive Components• Single and multi-core cables, shielded, for high temperature, hydraulic liquid resistant type

Thermometry• Thermo couple and thermoresistance extension cables for high temperature and heavy duty

Engineering - Plants• Single and multi-core cableslow fire hazard type(self-extinguishing, low smoke,hazardous and corrosive gasesgeneration cables)• Data transmission cables

Motors• Miniaturized single - core cables for high temperature

Power GeneratingSystems• High temperature single and multi-core cables• Flexible high temperature watertight cables

Cranes & Lifts• Flexible multi-core remote cables for heavy duty• Spiral cables

Transport(Railway - underground)• Flexible cable - low hazard type• Data transmission cables

INTERNATIONALSTANDARDS & APPROVALS

FIRECEL SR114H CABLE

INSTRUMENTATIONCABLE

FIBRE OPTIC CABLE

FIRECEL MI CABLE

PVC FLEXIBLE CABLE

RUBBER FLEXIBLE CABLE

MARINE CABLE

SOLAR CABLE

“SILICONE INSULATEDHIGH TEMPERATUREFLEX CABLE”

“G.I CONDUITS &ACCESSORIES “COT””

“PVC COATEDG.I FLEXIBLE CONDUIT“DECOFLEX””

EMERGENCY LIGHTING

CABLE GLANDS“RUPAM”

CABLE LUGS “ACE”

PVC FLEXIBLE CABLE

BMS CABLES

SHIELDED CABLE

CAVICEL SPA –ITALY

CAVICEL SPA –ITALY

CAVICEL SPA –ITALY

CAVICEL SPA –ITALY

ITALIAN CABLECOMPANY – ITALY

ITALIAN CABLECOMPANY – ITALY

ITALIAN CABLECOMPANY – ITALY

ITALIAN CABLECOMPANY – ITALY

ITALIAN CABLECOMPANY – ITALY

“MANYFOLKSENTERPRISES– HONG KONG”

PERFECT TOOLS - INDIA

ROBUS - HONG KONG

RUPAM IMPEX

SUPER IMPEX – INDIA

SIECHEM - INDIA

PAIGE ELECTRIC - USA

IMC – ITALY

PRODUCT MANUFACTURER ISO/CSQ BSI ULIQ

NET TUV CIVILDEFENCE

Dubai AbuDhabi

IMQ Lloyd’sLPCB RINA MOPW ESMA BASEC

PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 6: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

PRODUCT INDEX

10

CABLES Page No.

INSTRUMENTATION CABLE300/500 V, BS5308 Part 1 Type 2

18

FIBRE OPTIC CABLE 19

EPR/LSZH FLEXIBLE300/500 V BS6500

20

HT 105Heat Resistant FlexibleCable 105oC

22

H07RN-F CABLERubber Flexible Cable 22

MARINE CABLE0.6/1KV Armoured Cable 24

SOLAR CABLESOLAR PV1-F ( 1800 V DC)

24

CABLES FORSPECIAL APPLICATION 25

SIHF CABLESilicone Insulated Cables 23

FIRECEL MIFire Resistant Cable300/500 V, IEC 60702-1 & 2

15

FIRECEL SR140Fire Resistant Armoured Cable0.6/1KV, BS 7846

14

FIRECEL SR114EFire Alarm Cable, Enhanced300/500 V, PH120

13

FIRECEL SR114HFire Alarm Cable, Standard300/500 V, PH60, PH120

12

NETWORK CABLES 30

27SHIELDED CABLE300/500V Flame Retardant PVC

28BMS CABLEBuilding Management Systems Cable ®

®

PRODUCTCATALOGUE 11

CABLES ACCESSORIES

Page No.

CABLE GLANDS 38

CABLE CLEATS 41

FLOOR BOX 43

PANEL WIRE 31

EBXL 1200 C SOLAR CABLE 32

FIBRE OPTIC CABLE 15G.I. CONDUITS & ACCESSORIESPVC/LSFH COATED G.I FLEX CONDUIT

34

INDUSTRIAL PLUGS & SOCKETS 33

WATER PROOF JUNCTION BOX 33

PVC COATED G.I FLEX CONDUIT 37

CABLE LUGS 39

PVC CONDUIT & ACCESSORIES 40

CABLE TIES 41

EMERGENCY LIGHTS 42

WATER PROOF ISOLATORALUMINIUM ENCLOSURE SWITCHES 43

CABLE REEL 43

PVC FLEXIBLE CABLE 31

PRODUCTCATALOGUE

Page 7: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Abu Dhabi & DubaiCivil Defence Approved

FIRE RESISTANT CABLESSR 114E solid conductor 300/500 VSR 114E-R stranded conductor 300/500 V

Cables up to 4 coresapproved by LPCB, Certificate N° 217g

Cable construction

ConductorsPlain annealed copper wire, solid class1 or stranded class 2 according to EN 60228.

InsulationHigh performance fire resistant siliconerubber type EI2 to BS EN 50363-1.

CablingInsulated cores are cabled together.

Overall ScreenAluminium/polyester tape.

Circuit Protective ConductorUninsulated tinned copper conductor of thesame section and class as the insulated conductorsin the 2-, 3- and 4-core cables. Drain wireof 0.5 mm2 tinned copper conductor is providedin cables with more than 4 conductors.

Outer SheathLSZH thermoplastic material type LTS3 toBS 7655-6.1. Colour red or white (other colours on request)

ApplicationsFIRECEL SR 114E are primarily intended for use in fire detection and fire alarm systems, emergency lighting circuits or if cables need to properly operate when fire resistance improvement is required.

Typical applications are:

• BS 5839-1 for enhanced fire resistant cables in fire detection and fire alarm systems for building• BS 5839-8 for voice alarm systems• BS 5839-9 for emergency voice communication systems.• BS 8519 for fire-resistant control cable systems for life safety and fire-fighting application – Category 2

Operating temperature-40°C to +90°C

Minimum bending radius6 times the outer diameter.

Colour code up to 4 cores to HD 3082 cores blue – brown3 cores brown – black – grey4 cores blue – brown – black – grey7 cores centre: brown 1st layer: brown – black – 4 cores white12 cores centre: brown – black – white 1st layer: brown – black – 7 cores white19 cores centre: brown 1st layer: brown – black – 4 cores white 2nd layer: brown – black – 10 cores white

Applicable StandardsBasic design BS 7629-1Fire resistant BS 6387 (cat. C-W-Z) EN 50200 (class PH120) BS 8434-2 (120 min)Flame retardant EN 60332-1-2Acid gas emission EN 50267-2-1Smoke density EN 61034-2

1312

Abu Dhabi & DubaiCivil Defence Approved

FIRE RESISTANT CABLESSR 114H Solid Conductor 300/500 VSR 114H-R Stranded Conductor 300/500 V

Cables up to 4 coresapproved by LPCB, Certificate N° 217f

Cable construction

ConductorsPlain annealed copper wire, solid class1 or stranded class 2 according to EN 60228.

InsulationHigh performance fire resistant siliconerubber type EI2 to BS EN 50363-1.

CablingInsulated cores are cabled together.

Overall ScreenAluminium/polyester tape.

Circuit Protective ConductorUninsulated tinned copper conductor of thesame section and class as the insulated conductorsin the 2-, 3- and 4-core cables. Drain wireof 0.5 mm2 tinned copper conductor is providedin cables with more than 4 conductors.

Outer SheathLSZH thermoplastic material type LTS3 toBS 7655-6.1. Colour red or white (other colours on request)

ApplicationsFIRECEL SR 114H are primarily intended for use in fire detection and fire alarm systems, emergency lighting circuits or if cables need to properly operate when fire resistance improvement is required.

Typical applications are:

• BS 5839-1 for enhanced fire resistant cables in fire detection and fire alarm systems for building• BS 5839-8 for voice alarm systems• BS 5839-9 for emergency voice communication systems.• BS 8519 for fire-resistant control cable systems for life safety and fire-fighting application - Category 2

Operating temperature-40°C to +90°C

Minimum bending radius6 times the outer diameter.

Colour code up to 4 cores to HD 3082 cores blue - brown3 cores brown - black - grey4 cores blue - brown - black - grey7 cores centre: brown 1st layer: brown - black - 4 cores white12 cores centre: brown - black - white 1st layer: brown - black - 7 cores white19 cores centre: brown 1st layer: brown - black - 4 cores white 2nd layer: brown - black - 10 cores white

Applicable StandardsBasic design BS 7629-1Fire resistant BS 6387 (cat. C-W-Z) EN 50200 (class PH120) BS 8434-2 (120 min)Flame retardant EN 60332-1-2Acid gas emission EN 50267-2-1Smoke density EN 61034-2

PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 8: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

1514

Abu Dhabi & DubaiCivil Defence Approved

FIRE RESISTANT ARMOURED CABLESFire Resistant CableMica/XLPE Insulation

Cable construction

ConductorsPlain annealed copper wire, stranded according to EN 60228 class 2.

InsulationMica/Glass fire resistant tape covered byextruded cross-linked XLPE compound.

CablingInsulated cores are cabled together.

BeddingLSZH thermoplastic material.

ArmourSingle layer of galvanized steel wires (SWA).

Outer SheathLSZH thermoplastic material.Colour black (other colours on request).tt

ApplicationsPower supply and signals transmission, indoors or outdoors even wet environment. For fixed laying in free air, in pipe or conduit, on masonry and metal structures or suspended. In places where in case of fire people are exposed to serious risks for emission of smoke, toxic and corrosive gases and where you want to avoid damage to facilities, equipment, goods. Suitable for feeding of: emergency exits, alarm signals, warning of smoke or gas, escalators. Suitable for laying underground direct or indirect.

Operating temperature-40°C to +90°C

Minimum bending radius12 times the outer diameter.

Colour code up to 4 cores to HD 3082 cores blue – brown

3 cores brown – black – grey

4 cores blue – brown – black – grey

7 cores cores and above white numbered

Applicable StandardsBasic design BS 7846

Fire resistant BS 7846 (cat. F2) / BS 6387 (cat. C-W-Z) /

EN 50200 (PH60)

Flame retardant EN 60332-1-2

Fire retardant EN 50266-2-4 (cat. C)

Acid gas emission EN 50267-2-1

Smoke density EN 61034-2

R-mXLPE/LSZH/SWA/LSZH 0.6/1 kVFirecel SR 140 Armoured

Abu Dhabi & DubaiCivil Defence Approved

Fire Resistant Cable

Mineral insulated copper cables show outstanding performance in case of fire. Due to the specific constructions, FIRECEL MI cables can exceed all tests according to international standards for fire resistance.

Compared to soft skin cables, they show unique resistance for long time to temperature, to mechanical shocks and water. The cable can be bent also after a fire, it can withstand further impacts and water immersions.

The disadvantages, compared to soft skin cables, are the installation, that requires much more time, the seals and the connection process, which require specific tools and care for mineral oxide humidity absorption, and higher cost of cable.

Firecel MI 900LLight Duty Cables [300/500V]

from 2 to 7 cores, from 1 to 4 sqmmLPCB Certificate Number 217h/01

Firecel MI 901HHeavy Duty Cables [450/750V]single core, up to 400 sqmmLPCB Certificate Number 217h/02

Firecel MI 900HHeavy Duty Cables [450/750V]

from 2 to 19 corners, from 1,5 to 25 sqmmLPCB Certificate Number 217h/03

PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 9: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Abu Dhabi & DubaiCivil Defence Approved

MI 900L Light Duty Cables (300/500V) – multicoreMI 901H Heavy Duty Cables (450/750V) – singlecoreMI 900H Heavy Duty Cables (450/750V) – multicore

approved by LPCB,Certificate N°

217h/01, 02, 03

Cable construction

ConductorsETP solid (not stranded) copper cores, from 1 to 400 mm2,melting point 1082°C Insulation

Mica/Glass fire resistant tape covered by high performancefire resistant silicone rubber type EI2 to BS EN 50363-1.

CablingMagnesium Oxide (MgO) as electrical insulation,high performance at high temperature (melting point 2600°C)

Metallic Outer SheathHigh quality DHP copper sheath, manufactured starting fromtubes extruded and drawn only (not welded),melting point 1082°C

Outer SheathLSZH additional outer covering. Such flame retardantpolyolefin is characterized by high performance in corrosion resistance and low smoke emission.

Production process foresee many steps of diameter reduction(both drawings and rollings) separated by high temperatureannealing. Strong compression of MgO powder (density about2 g/cm3) allows very high values of insulation resistance(also if burned, 180° bent or flattened) and thermal conductivity. Therefore current ratings are higher than soft skin cables, especially at high temperature.

ApplicationsFIRECEL MI are intended to be installed in critical safety circuits which are used to operate under fire conditions in severe applications where the mechanical cables performances are primarily required. Typical applications are:TunnelsIndustrial Plants Harsh EnvironmentsHazardous AreasHistorical Buildings

These cables comply with following standards:BS 5839 “Fire detection and fire alarm systems for buildings. Code of practice for system design, installation, commissioning and maintenance”BS 5266 “Emergency lighting. Code of practice for the emergency lighting of premises”

Operating temperature-40°C to +250°C

Minimum bending radius6 times the outer diameter.

Applicable StandardsBasic design IEC 60702-1 & 2

Fire resistant BS 6387 (cat. C-W-Z)

BS 8434-2

EN 50200 annex E

IEC 60331-21

Flame retardant EN 60332-1-2

Acid gas emission EN 50267-2-1

Smoke density EN 61034-2

SR SERIES - FIRE RESISTANT CABLESSR Series - Fire Resistant Cables

ApplicationsHotelsTheatres and cinemasMuseumsHospitalsShopping centresOfficesSchoolsAirportsUndergrounds and tunnelsRailway stationsHigh-rise buildingsData communication centresPublic address systemsTraffic control systemsFire fighting systems

StandardsCables can be designed, manufactured andtested according to:BSIECENDINNBNand others on request.

Fire Test LaboratoryCAVICEL has a well equipped laboratory to testcable performance under fire condition.We can certify following tests: Resistance to fire aloneResistance to fire with waterResistance to fire with mechanical shocksSmoke emissionGas evolved during combustionFire and flame propagationOxygen indexTemperature index

ApprovalsDepartment of Social Services Abu DhabiCivil Defence Directorate Abu DhabiADWEA Abu DhabiCivil Defence Directorate DubaiCivil Defence BahrainCivil Defence Department QatarFire Service Directorate KuwaitRoyal Oman Police Sultanate of OmanMinistry of Public Works UAEFire Service Dept. (Fire Protection Bureau)

Firecel SR cables are fire resistant cables designedto continuously operate under fire conditions.During the burning stage, the combustion gaseshave very low opacity, low toxicity and arehalogen free, for the safeguard of the human lifeand for protection of installations.

FIRECEL SR 125 E30Silicone InsulationOverall Screen300/500 V

FIRECEL SR 125RF1Silicone InsulationOverall Screen300/500 V

FIRECEL SR 125 HSilicone InsulationOverall Screen300/500 V

FIRECEL SR 225 HMica/XLPE InsulationOverall Screen300/500 V

FIRECEL SR 118Silicone Insulation300/500 V

FIRECEL SR 220Mica/XLPE Insulation300/500 V

FIRECEL SR 109Flexible-Silicone InsulationOverall Screen450/750 V

FIRECEL SR 116HSilicone Insulation450/750 V

FIRECEL SR 112Single/Twin Core Mica/XLPEInsulation450/750 V

FIRECEL SR 206Mica/XLPE Insulation0.6/1kV

FIRECEL SR 106HSilicone Insulation0.6/1kV

1716 PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 10: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Fire Resistant Fibre Optic Cables

ApplicationsTelecommunicationData TransmissionVideo ApplicationLocal Area NetworkSurveillance and Safety SystemsRailway ApplicationProcess Control

StandardsIEC 60793-2-50IEC 11801IEC 60793-2ITU-T EIA/TIA 455EIA/TIA 492EIA/TIA 568EN 50173FDDI

ConstructionStandard Fibres:Single mode 9/125NZDSFMultimode 50/125Multimode 62.5/125Multimode 200/230Special fibres available on request.

Fibre ProtectionsTightSemi-TightSingle-fibre loose tubeMulti-fibre loose tubeRibbon

Special ConstructionsFibre optic cables can be designed andmanufactured with materials and structures that allow high performances,such as:

Resistance to continuous bending (for mobile applications)Resistance to high temperatureResistance in harsh environment(Mud resistant jacket)Fire resistance, assuring performances evenduring a fire (standard IEC 60331-25)

SIMSimplex

DupDuplex

FDI-A5Multitight DistributionDielectric Armour

MTI-A1-AICIMultitight DistributionMetallic Armour

MLDMuitifibre Breakout

MLD-A1Multifibre BreakoutMetallic Armour

SLOSingle Tube

SLO-A1Single TubeMetallic Armour

SLO-A3Single TubeMetallic Armour

MLO-A3Multi TubeMetallic Armour

MLO-A7Multi TubeMetallic Armour

SLO-A5-FRSingle Tube

SLO-A3-FRSingle TubeMetallic Armour

SLO-A7-FRSingle TubeMetallic Armour

MLO-A1-FR-QFCIMulti TubeMetallic Armour

Fire Resistant

Fire Resistant

Fire Resistant

Fire Resistant

ProtectionsA1Galvanized SteelWire Braid

A1Aramid Yarns

A1Corrugated Steel Tape

A1Special Rodent ResistantExtruded Polyamide Jacket

A5Glass Yarns

A7Galvanized SteelWire armourA8Copolymer CoatedAluminium TapeA9Hi Pack-Special MultilayerProtection (Aluminium/PE/PA)

Cable construction

ConductorsPlain annealed electrolytic copper wire according to EN 60228class 1(U) solid, class 2 (R) stranded, class 5 (F) flexible.Mica/Glass fire resistant tape covered by high performancefire resistant silicone rubber type EI2 to BS EN 50363-1.

InsulationPVC, PE, XLPE or LSZH thermoplastic material.

TwistingThe insulated cores shall be twisted in pairs for a goodreduction of the electromagnetic noise.

Individual screenAluminium/polyester tape, coverage >100%, aluminium incontact with tinned copper drain wire.

CablingThe screened pairs are cabled with suitable non hygroscopicfillers (when necessary) and wrapped with polyester tapeif required.

Overall screenAluminium/polyester tape, coverage >100%, aluminium incontact with tinned copper drain wire.

Inner sheathPE, PVC or LSZH thermoplastic material.

ArmourSingle layer of galvanized steel wires (SWA).

Outer sheathPVC or LSZH thermoplastic material.

ApplicationsCan be used in cable tray or conduit to connect electrical instrumentation and communication circuits in industrial process controls, refineries, oil and gas plants.

Operating temperature-20 °C to +80 °C (for general use);-40 °C to +90 °C (on request).

Minimum bending radiusNot armoured type:12 times the outer diameter (for conductors class 1 and class 2);10 times the outer diameter (for conductors class 5).Armoured type: 15 times the outer diameter.

Applicable StandardsBS 5308 orEN 50288-7 Basic designIEC 60332-1 Flame retardantIEC 60332-3 Fire retardant (cat. C or A according to requirements)IEC 60754-1 Halogen free properties (only for LSZH cables)IEC 61034-2 Low smoke emission (only for LSZH cables)

Available on requestTinned conductors.Single triad or multitriads.Galvanized steel wire braid (GSWB) or galvanized steel tape armour (GSTA).Different insulation and sheath colours.Sheath materials can be provided for excellent water, oil, hydrocarbons,UV resistance or other special performance.

INSTRUMENTATION CABLESMultipair/Triad Overall Screen

Not ArmouredPE/OS/PVCXLPE/OS/LSZH

ArmouredPE/OS/PE/SWA/PVCXLPE/OS/LSZH/SWA/LSZH

1918 PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 11: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Cable constructionConductors : Flexible tinned annealed copper wiresInsulation : EPR, type GP6 to BS 6899Insulation Colours Without Earth- 2 cores : blue - brown- 5 cores : blue - brown – black – grey - blackWithout Earth - 3 cores : yellow/green - blue - brown- 4 cores : yellow/green – brown – black – grey Cabling : The insulated cores are cabled togetherBedding : LSZH thermoplastic compoundRipcord : LSZH thermoplastic compoundOuter sheath : LSZH thermoplastic compoundOuter sheath colour : WhitePrinted marking : CAVICEL ITALY – FIRECEL LS EPR/LSZH - FLEXIBLE - n° of cond. x size mm2 – 300/500 V – year of manufacture + Arabic marking + meter marking

EPR /LSZH - FLEXIBLE CABLE

NO OF CORESX Size [mm2]

P/N InsulationThickness [mm]

Nom. outer sheaththickness [mm]

Outer diameterMin. [mm]

Weight[kg/km]

Max pullingtension [mm]

Min. bending[mm]

Flame retardant special LSZH flexible cablesF(T)-EPR/LSZH - 300/500 V

Flame and fire retardant, low smoke and zero halogen

Cable construction

79389 2x0.75 0.6 0.9 6.5 60 6 45

79390 2x1.5 0.7 1.0 8.0 90 11 56

75023 3x1.5 0.7 1.0 8.5 103 18 60

75024 3x2.5 0.7 1.0 10.0 140 30 70

75281 3x4 0.7 1.1 11.1 215 45 78

75423 3x6 0.7 1.2 13.0 298 71 91

75282 4x1.5 0.7 1.0 9.00 135 22 63

75283 4x2.5 0.7 1.1 10.8 200 36 76

75284 4x4 0.7 1.1 12.2 290 61 85

75424 4x6 0.7 1.3 14.0 374 95 98

79014 5x2.5 0.7 1.1 11.8 250 44 83

Mechanical and installation characteristicsOperating temperature (after installation) -30°C ÷ +80°C

General standardsIn general for the construction BS 6500For the conductors EN 60228 / IEC 60228 (class 5)

Behaviour under fire conditionsFlame retardant (NPF) IEC 60332-1-2 EN 50265-2-1 CEI 20-35/1-1Fire retardant cat.C IEC 60332-3-24 EN 50266-2-4 CEI 20-22/3-4Corrosive acid gas (≤ 0.5% acid gas) IEC 60754-1 EN 50267-2-1 CEI 20-37/2-1Smoke density (Light transmittance min.60%) IEC 61034-2 EN 50268-2 CEI 20-37/3-1

Electrical characteristicsVoltage rating 300/500 V r.m.s.Spark test insulation 7000 V r.m.s. / H.F.Conductors resistance ≤ 13.7 Ohm/km (at 20°C in d.c.) for 1.5 mm2 ≤ 8.21 Ohm/km (at 20°C in d.c.) for 2.5 mm2 ≤ 5.09 Ohm/km (at 20°C in d.c.) for 4 mm2 ≤ 3.39 Ohm/km (at 20°C in d.c.) for 6 mm2Insulation resistance ≥ 1000 MOhmxkm (at 70°C in d.c.)

ST/0906/14 09/06/2009Rev.0

Special Cables

Market RequirementsThe on-going evolution of technology pushes the demand for special products to meet specific requirements.

ApplicationsOur Special Cables can be installed in the following fields:Power PlantRefineries and Petrochemical PlantsOff-shoreElectronic ApplicationsFire-fighting SystemsRailways-UndergroundIron and Steel PlantsContractors - EngineeringMobile ApplicationsSteel worksDesalination plants

MaterialsIn order to offer the best solution to every enquiry, CAVICEL can process following materials:PVCPolyethyleneHDPEXLPENylonPolyurethaneTPELSZHSilicone rubberTeflon*FEPTeflon*PFATeflon* PTFEHyflon* MFATefzel* ETFEHalar*Hytrel*Peek*Kapton*

Numbers of Success• 50 years’ experience in designing and producting cables. • Export sales in more than50 countries. • A laboratory in the forefrontfor fine tests. • 300 fire tests carried out every year. • Over 3000 new projects developed every year.

Clients that rely on CAVICEL know that they can count on a company that deeply knows cable problems and works hard, day by day, to understand customer’s need. A company that proposes new solutions, more sophisticated or endowed with the best Quality for the right price. That is the reason why CAVICEL has a global answer for every country, every standard, every need.

Cables for extreme temperatures

Composite CablesFibre Optics andcopper conductors

AccessoriesCAVICEL can supply LSZH P Clips and LSZH glands for fire resistant cables, splice closures for fibres, and give assistance forOn-field Installation.

Cables with Ballistic Protection

Pre-terminated Optical cables

Cable withcustomized design

HDCLinear HeatDetector Cable

Continuous heat detector: at the rated temperature the insulation melts, permitting the conductors to short circuit and generate alarm signal.Two temperature alarm levels are available: 68oC and 105oC

Cables can be designed to work - 60oC up to more than +260oC.Cables can be insulated by silicone rubber, Teflon, Tefzel, Kapton, PEEK, or Special heat resistant tapes.

These cables house either copper conductor or Fibre optics.Many constructions are available: cable in the picture, for example, shows a watertight construction with a central stainless tube for fibres, while copper conductors surround the core. A steel wire armour assures high mechanical protection.

Copper/fibre optic cables, with ballistic protection, able to resist shotguns pellets. Cables can be supplied with a self supporting construction.

Cables for special applications can be supplied with multiple connectors (quick coupling) properly installed and ready for an easy installation.

Many cables can be developed according to customers’ needs, by looking for the best solutions, the right materials and the proper design. And prototypes of cables can be manufactured and tested in order to get the full approval.

2120 PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 12: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

High Temperature Silicon Insulated CablesSIHF

1- Flexible copper class 5 IEC2282/3- Silicone rubberOPT: Available with high temperature or abrasion resistant silicone rubber

CharacteristicsWorking temperature: -60 to 1800 C Working voltage: 500 V Test voltage: 2000 V

ConductorAvailable in bare, tin or nickel plated copper

Applications

1- Flexible copper class 5 IEC228 2/3- Silicone rubber4- Fiberglass braid

CharacteristicsWorking temperature:-60 to 2000 C Working voltage: 500 VTest voltage: 2000 V

ConductorAvailable in bare, tin or nickel plated copper

Applications

300/500V, 850C - BS 6500

SpecificationsConductor Flexible copper conductor class 5 BS 6360Insulation Rubber insulation type GP1 BS 6899Sheath Rubber type RS3 BS 6899Rating voltage U0/U 300/500V

HIGH TEMPERATURESILICON INSULATED CABLES

SIHF/GL

EPR / HOFR Flexible CableEPR Insulated, HOFR Sheathed Flexible Cable

ApplicationIn domestic premises, kitchens, officesIn high ambient temperatures for household appliances, including in damp premisesFor medium duties (e.g washing machines, spin dryers, and refrigerators)Internally in equipment

1. Flexible copper class 5 CEI EN 602282. PVC TI33. PVC TM3

StandardsCEI 20-20/12 HD 21BS 6500Conductor Flexible class 5 copper conductors to BS6360Insulation PVC Type TI 3 to BS7655Sheath PVC Type TM 3 to BS7655Colour WhiteVoltage Rating 300/500VTemperature Rating 0 to +105°CMax. temperature ofshort circuit 150° C on the conductor (max. duration 5 seconds)Min. bending radius Mobile installation: 4 x outer diameterFixed installation 3 x outer diameter

Flexible cables epr rubber insulated, polychloroprene sheathed.1- Flexible copper class 5 CEI EN 602282- Rubber type EI43- Rubber type EM2

CharacteristicsOperating temperature: -25°C ÷ +60° C on the conductorRated voltage: 450/750 VMax temp. of short circuit: 200° C on the conductor (max duration 5 seconds)Min bending radius: Mobile installation: 4 x outer diam. Fixed installation: 3 x outer diam.

Applications

HT - 105OC - Heat Resistant Cable

H07RN-F Rubber Flexible Cables

2322 PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 13: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

ARMOURED, FIRE RETARDANT, HALOGENFREE AND LOW SMOKECONTROL AND POWER CABLES XLPE INSULATED, SHF1 SHEATHED.1 - Plain copper: Class 2 IEC 60228 // Class 5 IEC 602282 - Cross Linked Polyethylene HFXLPE3 - Extruded inner sheath4 - Plain copper wire braid5 - SHF1 LSOH thermoplastic compound

StandardsIEC 60092-350 IEC 60754-2IEC 60092-351 IEC 60228IEC 60092-352 IEC 60332-1IEC 60092-353 IEC 60332-3-22IEC 60092-359 IEC 61034-1IEC 60754-1 IEC 61034-2

Single Core Cables, for photovoltaic and Solar System use,Elastomeric Compound insulated and Sheathed.Flame retardant, halogenfree and low smokeFlexible Cables for fixed laying, lifetime testing 20.000 H/12OC 1- Flexible tin plated copper class 5 EN 602282- LSOH Rubber compound

ApplicationsCable suitable for the interconnection of the various elements of photovoltaic systemsSuitable for fixed installation outside and inside without protection orinside pipes, ducts or similar closed systems.High resistance against Ozone, U.V rays, oils, moisture and weather inclemenciesSuitable for use at an ambient temperature up to 90°C (120°C overload)and tested according to: TÜV-Rheinland 2 Pfg 1169/08.2007 Standard.The estimated lifetime of these cables is at least 25 years.

CharacteristicsSheath Colour: Black, RedOperating temperature: -40°C ÷ 90°C on the conductorOverload temperature: 120°C on the conductorExpected Lifetime: >25 yearsRated voltage: 1800 V DCMax. temperature in case of short circuit: 250° C on the conductor (max duration 5 seconds)Min. bending radius: 4 x outer diameter of the cableMin. installation temperature: -25°CMax laying stress during installation: 50 N/mm2

SXAM-HF Marine Cables

Solar CableSolar PV1-F

MARINE SOLAR CABLESCables for Special Applications

FG21M21Single core cables, for photovoltaic and solar system use, insulated in type G21 elastomeric compound and M21 elastomeric compound sheathed. Flame retardant, halogenfree and low smoke flexible cables for fixed laying, lifetime testing 20.000 h/120°C.

FG7R FG7ORFire retardant, LSF power, control and signalling cables, insulated in type G7 elastomeric compound and PVC sheathed with flexible conductors for fixed installation.

H05RN-FFlexible cables EPR rubber insulated, polychloroprene sheathed.

H05V2-K H07V2-KFlexible single core PVC insulated electric cables, sheathless, for internal wiring and for general use, with continuous operating temperature of 90°c.

H05VVH6-F H07VVH6-FFlexible flat cables PVC insulated, PVC sheathed.

NSGAFÖUFlexible power cables rubber insulated, polychloroprene sheathed.

SXAM331-HF 0,6/1 KVFire resistant, power cables for shipboard and offshore applications. Armoured, fire retardant, halogenfree and low smoke control and power cables XLPE insulated, SHF1 sheathed.

TRI-RATEDTri-rated switchgear & control panel wires.

2524 PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 14: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

These cables are employed for pulse operated or AC circuits in control, measuring and signalling technology as well as in data processing and office technology. Twisting in pairs provides optimum crosstalk attainability.

Temperature range-50C to +700Cstatic : -300C to +700C

Working Voltage0.14 - 0.25mm2 - 250V0.34 - 0.75mm2 - 300Vfrom 1.00mm2 - 500V

Liycy Paired - Flexible Data Transmission Cable

2 x 2 x 0.14 5.7 393 x 2 x 0.14 5.8 484 x 2 x 0.14 6.2 546 x 2 x 0.14 7.1 858 x 2 x 0.14 8.2 9710 x 2 x 0.14 8.7 11012 x 2 x 0.14 8.9 14216 x 2 x 0.14 10.2 15420 x 2 x 0.14 11.3 18425 x 2 x 0.14 12.5 23830 x 2 x 0.14 13.1 2702 x 2 x 0.25 7.0 543 x 2 x 0.25 7.1 664 x 2 x 0.25 7.6 816 x 2 x 0.25 8.5 1158 x 2 x 0.25 10.3 13010 x 2 x 0.25 11.0 15812 x 2 x 0.25 11.3 19016 x 2 x 0.25 12.5 23825 x 2 x 0.25 16.1 3442 x 2 x 0.5 8.6 933 x 2 x 0.5 8.7 1294 x 2 x 0.5 9.4 1466 x 2 x 0.5 11.1 1988 x 2 x 0.5 13.1 25912 x 2 x 0.5 14.9 35416 x 2 x 0.5 16.5 4592 x 2 x 0.75 9.3 1063 x 2 x 0.75 9.4 1404 x 2 x 0.75 10.7 1795 x 2 x 0.75 11.1 2156 x 2 x 0.75 12.1 2468 x 2 x 0.75 14.7 30512 x 2 x 0.75 16.2 4562 x 2 x 1.0 10.3 1423 x 2 x 1.0 10.4 1734 x 2 x 1.0 11.3 2125 x 2 x 1.0 11.8 266

No. of cores andmm2 per conductor

Approx.weight

Approx. outerdiameter in mm

ConstructionFine strands of bare copper conductorStranding acc. to VDE 0295, class 5 PVC core insulationCore marking acc. to DIN 471002 cores twisted in pairsPairs twisted in layersFilm wrappingoverall screen of tinned copper wiresPVC outer sheath grey, RAL 7001 or 7032

Shielded Cable

Eib Bus Cable2 Pair 0.8mm E.I.B Cable

ApplicationsData transmission cable, control and connecting cable predominantly for transmission of analog and digital signals in process controlled facilities in measurement and control technology for lossless transmission of data and signals. For fixed laying and flexible applications with undefined cable routing and without tensile stress. Suitable for use in dry and humid rooms. Outdoor use only with UV - protection, no laying underground.

Special FeaturesTwisted pairsLargely resistant to acids, bases and usual oilsFree from lacquer damaging substances and silicone (during production)Recommended for EMC - application

RemarksConform to ROHSConform to 2006 / 95 / EC = Guideline CESpecial versions, other dimensions, core and jacket colours can be produced on request

Integration of Building Management Systems over one common system. Lighting, blinds, heating and ventilation can be automatically controlled through the E.I.B cable. This dramatically reduces the cabling required in a modern building.

ConstructionPlain copper conductors 0.8mm, Polyethylene insulation, cores twisted into pairs, pairs laid up, aluminium/polyester foil screen, stranded tinned copper drain wire

Core identification Red, black, yellow, whiteConductor 0.8mm tinned copperSheath colour Green Operating temperature -20°C to +70°C fixed -5°C to +50°C installation Voltage Working : 150VConductor resistance 37.0 Ω/km @ 20°CMutual capacitance 100nF/km maxUnbalanced capacitance 300pF/100m maxInsulation resistance 1000M Ωhms*km @ 20°C.

(European Installation Bus)

2726 PRODUCTCATALOGUE

PRODUCTCATALOGUE

SHIELDED CABLES

Page 15: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Country of Origin: United States of AmericaISO 9001:2008 CertifiedUL, CSA, NEC, NFPA, etc listed.PVC, LSF & LSZH available.ROHS complaintLON, BACNet, Modbus, M-bus, EIB, Profibus, Field bus compatible

ELV Cables

Sl. No. Paige Part # Cores AWG Shield Jacket mm Dia mm2 Area Type Application

1 454625 2 18 Yes PVC 1.02 0.82 -2 455300UE 2 18 No PVC 1.02 0.82 -3 455200FE 2 16 Yes PVC 1.29 1.31 -4 455200UE 2 16 No PVC 1.29 1.31 -5 454656 2 16 No PVC 1.29 1.31 -6 458760 2 18 Yes PVC 1.02 0.82 RS4857 458761 2 22 Yes PVC 1.65 0.33 RS4858 3781S 2 22 No PVC 1.65 0.33 RS485 BMS9 455301FE 3 18 Yes PVC 1.02 0.82 - Access Control10 3724 3 8 No PVC 1.02 0.82 - Lighting Control11 741803CMR 3 18 No PVC 1.02 0.82 - Central Battery Control12 455501FE 3 22 Yes PVC 0.65 0.33 - Home Automation13 455302FE 4 18 Yes PVC 1.02 0.82 - Guest Room Management14 455302UE 4 18 No PVC 1.02 0.82 - Chiller Management15 3726 5 18 No PVC 1.02 0.82 - Car Park Exhaust System16 455506FE 8 22 Yes PVC 0.65 0.33 - CO Monitoring System17 458471NH 2 16 No LSZH 1.29 1.31 - LON Communication18 444625LS 2 18 Yes LSF 1.02 0.82 - BACNet Communication19 444625LSZH 2 18 Yes LSZH 1.02 0.82 - Modbus Communication20 444640LSZH 2 18 No LSZH 1.02 0.82 -21 458760NH 2 18 Yes LSZH 1.02 0.82 RS48522 70C1254ZH 8 14 Yes LSZH 1.63 2.08 -23 458723NH 4 22 Yes LSZH 0.65 0.33 -24 459842NH 4 24 Yes LSZH 0.51 0.2 -25 70C1220BL 2 20 Yes LSZH 0.81 0.52 EIB EIB / KNX26 70C1220GY 2 20 Yes LSZH 0.81 0.52 EIB Communication27 70C1219 2 20 Yes PVC 0.81 0.52 EIB28 9X234C62B1 8 24 No PVC 0.51 0.2 CAT 6 Networking29 454609 4 22 No PVC 0.65 0.33 -30 454611 6 22 No PVC 0.65 0.33 - Access Control31 454613 8 22 No PVC 0.65 0.33 - Security System32 740160M 1 20 Yes PVC 0.81 0.52 RG5933 454802 1 18 Yes PVC 1.02 0.82 RG634 454807 1 14 Yes PVC 1.63 2.08 RG11 CCTV35 45RG59LSF 1 20 Yes LSF 0.81 0.52 RG59 CATV36 45RG6LSF 1 18 Yes LSF 1.02 0.82 RG6 MATV37 45RG11LSF 1 14 Yes LSF 1.63 2.08 RG1138 RG59+2P 1+4+3 18+24+16 Yes PVC - - COMP

®

WIRE & CABLES /APPLICATIONS

ADT

Keypad

Access Control

LAN, Data & Networking Solutions

Annunciator

Low Capacitance Cables

Armored Cables

Microphone

Audio Cables

Motion Detector

Card Reader Cable

Motorola

Category Cables

Network cables

CATV

Notifier

Circuit Integrity Cable

Nurse Call Cables

Coaxial Cable

Patch Cables

Communication Cable

Security Cables

Custom Cables

Sensormatic

Data Cables

Simplex Grinnell

Direct Burial, Power

Sound Cables

Distinguisher

Sounder Base Cables

Fiber optic cable & Accessories

Smoke Detectors

Honeywell

Speaker Cables

Horn / Strobe

Telephone Cables

Intercom

Thermostat Cable

Made in USA

®

®

28 29PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 16: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

PVC Flexible Cables

Panel Wires

Siechem APC Conductor, PVC Insulated,Unsheathed General Purpose 600/1000 V Singlecore 1050C Flexible Cables As Per BS 6231 Type CK

ApplicationUsed in indoor / outdoor as control cables in industriesExcellent UV - protectionUsed in dry, damp or wet interiorsFlexible

FeaturesHighly resistant against acids, dyes, certain oils at room temperatureImproved sliding effectFlexible conductors with soft PVC insulation sheath for flexibilityConforms to BS 6500

Product ConstructionConductor: Finely standard bare copper wires Insulation: PVC compoundFilling material: PVC compoundOuter sheath: PVC material and with white colour Coloured cores

Siechem, Annealed plain flexible (Class 5) Copper Conductor PVC insulated Unsheathed Single core 450/750 V rated cable as per BS 6004

ApplicationTri-rated Cable panel wiring is a high temperature, cable designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

Insulation ColourBlack, Red, Blue, Yellow, Green/Yellow, Grey.1- Flexible copper class 5 CEI EN 60228 2- PVC TI1

Electrical CharacteristicsOperating Temperature: +5°C ÷ +105° C on the conductorRated voltage: H07V-K: 450/750 VMax. temperature of short circuit: 160° C on the conductor (max. duration 5 seconds)Min. bending radius: Fixed installation: 4 x outer diameter

ApplicationSuitable for lighting circuits and building wiringUsed in closed installation ducts, embedded conduits, Shopping malls,High rise buildings & IndustriesInternal wiring of appliances and apparatus Power, Switchgear & control gear appliances

FeaturesFlame retardantFlexibilityMedium Mechanical Stress.

Product ConstructionConductor : Annealed copper conductor, class 5 flexible conductor as per BS 6360Insulation : HR PVC 1050C. (Green/Yellow, Blue or other colours)

Technical DataTemperature Range : -250C to +1050CRated Voltage : 600/1000VTest Voltage : 1.5 x rated voltageBending Radius : 5 x OD

NETWORK CABLES CAT 5E/6/6ACategory 5 E/6/6A

StandardsUL/ CSA Listed CM ,CMR, CMP, LSOH, UL/ AND ELT verified to ANSI/TIA,EIA- 568-B Category 5eISO/IEC-11801NEMA WC 63.1

ApplicationANSI x 3T9.5-PMD (FDDI)Proven support for GigabitEthernet / 1000 BASE-T/ IEEE 802.3ab 10 Base-T100 Base-T4100 Base –xIEEE 802.54/16 Mbps Token RingIEEE 802.12100 Base –VG

Electrical PropertiesISO/IEC 11801, TIA/EIA 568-A Impedance 100 Ω± 5%Max. d.c resistance 14.8 Ω/100m (26AWG)Max. resistance unbalance 3% (5% for TIA/EIA)Min. propagation velocity 0.65 CMax. Mutual capacitance 5.6nF/100mMax. capacitance unbalance 3400/3300pF/Km (ISO/IEC,TIA/EIA) Max. d.c resistance 9.38Ω/100m (24AWG)Max. d.c loop resistance 19.2Ω /100mMin. d.c insulation resistance 150MΩ/KmMax. Propagation delay skew 30 ns/100m

Construction

4 24AWG (0.49mm) 0.18 0.0071 4.8 0.193 PVC HDPE

No. ofpairs

Conductor

23AWG (0.575mm)

Insulation thickness

mm Inch

outer diametrejacket Insulation

mm Inch

4 0.25 0.0098 6.3 0.248 PVC HDPE

4 0.25 0.0098 6.3 0.248 PE HDPE

4 0.25 0.0098 6.3 0.248 LSPVC TEFLON

4 0.25 0.0098 6.3 0.248 LSZH HDPE

No. ofpairs Conductor

Insulation thickness

mm Inch

outer diametrejacket Insulation

mm Inch

®

3130 PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 17: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Industrial Plugs And Sockets IP44 / IP67

Water Proof Junction Boxes, with good quality, Manufactured as per IP65 by GEROS ELECTRICAL ENGINEERING, Italy. Geros products have CE certification in respect of rules CEI 23-48 CEI C. 538 and IEC 670, in harmony with 73-23 and 93-68 instructions.

Packing Qty./ minimum & multiple order

1 GR 17003 SURF. BOX SMOOTH WALLS IP65 83X83X43 2 GR 17004 SURF. BOX SMOOTH WALLS IP65 100X100X60 3 GR 17008 SURF. BOX 6 SMOOTH WALLS IP65 150 X110X75 4 GR 17010 SURF. BOX SMOOTH WALLS IP65 150X140X75 5 GR 17011 SURF. BOX SMOOTH WALLS IP65 190X140X75 6 GR 17012 SURF. BOX SMOOTH WALLS IP65 170X170X75 7 GR 17014 SURF. BOX SMOOTH WALLS IP65 240X190X90 8 GR 17016 SURF. BOX SMOOTH WALLS IP65 310X240X100 9 GR 17242 SURF. BOX SMOOTH WALLS IP65 310X240X120 10 GR 17246 SURF. BOX SMOOTH WALLS IP65 380X300X180 11 GR 17248 SURF. BOX SMOOTH WALLS IP65 460X380X120

SI.No DescriptionPart Number

DescriptionPart Number

GR30409 MOVABLE PLUG. 2P 16A+T 220V BLUE IP 67 10/10GR30410 MOVABLE PLUG 2P16A+T 220V BLUE IP44 10/10GR30415 MOVABLE PLUG 3P 16A+T 380V RED IP 67 10/10GR30416 MOVABLE PLUG 3P16A+T 380V RED IP44 10/10GR30417 MOVABLE PLUG 3P 16A+N+T 380V RED IP 67 10/10GR30418 MOVABLE PLUG 3P 16A+N+T 380V RED IP 44 10/10GR30419 MOVABLE PLUG 3P 32A+T 380V RED IP 67 5/5GR30420 MOVABLE PLUG 3P 32A+T 380V RED IP44 5/5GR30421 MOVABLE PLUG 3P 32A+N+T 380V RED IP 67 5/5GR30422 MOVABLE PLUG 3P 32A+N+T 380V RED IP 44 5/5GR30450 MOVABLE SOCKET 16A 2P+T 220V BLUE IP44 10/10GR30451 MOVABLE SOCKET 16A 2P+T 220V BLUE IP67 10/10GR30456 MOVABLE SOCKET 16A 3P+T 380V RED IP44 10/10GR30455 MOVABLE SOCKET 16A 3P+T 380V RED IP67 10/10GR30457 MOVABLE SOCKET 16A 3P+N+T 380V RED IP67 10/10GR30458 MOVABLE SOCKET 16A 3P+N+T 380V RED IP44 10/10GR30459 MOVABLE SOCKET 32A 3P+T 380V RED IP67 10/10GR30460 MOVABLE SOCKET 32A 3P+T 380V RED IP44 10/10GR30461 MOVABLE SOCKET 32A 3P+N+T 380V RED IP67 10/10GR30462 MOVABLE SOCKET 32A 3P+N+T 380V RED IP44 10/10GR30509 FL. MOUNT. SOCKET 16A 2P+T 220V BLUE IP 67 10/10GR30510 FL. MOUNT. SOCKET 16A 2P+T 220V BLUE IP 44 10/10GR30515 FL. MOUNT. SOCKET 16A 3P+T 380V RED IP 67 10/10GR30516 FL. MOUNT. SOCKET 16A 3P+T 380V RED IP 44 10/10GR30517 FL. MOUNT. SOCKET 16A 3P+N+T 380V RED IP 67 10/10GR30518 FL. MOUNT. SOCKET 16A 3P+N+T 380V RED IP 44 10/10GR30520 FL. MOUNT. SOCKET 32A 3P+T 380V RED IP 67 10/10GR30522 FL. MOUNT. SOCKET 32A 3P+N+T 380V RED IP 67 10/10GR30550 SURFACE SOCKET 16A 2P+T 220V BLUE IP 67 10/10GR30556 SURFACE SOCKET 16A 3P+T 380V RED IP 67 10/10

Water Proof IP 65 Junction Boxes

EBXL XLPE LT Power Cables

Multicore Electron Beam Cross Linked Solar Cable As Per TUV & Ul Specification

ConstructionConductor : Annealed Tinned Copper (APC Optional) according to IEC 60228, Class 5 or as per customer orderInsulation : XLPE 1200C (Color Red, Yellow, Blue, Black & Green) Jacket : XLPE Highly weather & UV Resistant (colour Black)

Type of Solar CablesTUV : Siechem Single & Multi Core and Screened Solar cables meets specn.2Pft 1169/08.2007UL : Siechem Single & Multicore and Screened Solar Cables meets UL 4703 Siechem Dual : Single & Multicore and Screened cables to meet both TUV & UL specn.

Siechem Solar Cable RangeSingle Core : 1.5 to 400 sq.mm or its equivalent size in AWGMulti Core : 2 to 4 cores x 1.5 to 400 sq. mm or its equivalent size in AWGMulti Core (EMC) : Up to 61 core screened cables (data sheet against specificrequest for EMC cables)

Siechem 145 Flexible Single And Multicore EBXL Cables

ConstructionConductor : Annealed Tinned Copper (APC Optional) according to IEC 60228, Class 5 or as per customer orderInsulation : XLPE 1200C (Color Red, Yellow, Blue, Black & Green) Jacket : XLPE Highly weather & UV Resistant (colour Black)

ConstructionOperating temperature -400c to +1250C (20,000 hours)(Briefly -550C to +1450C)Fire retardant and Halogen free Weather resistantHigh abrasion resistanceOzone & UV resistantOil & grease resistant High tracking resistanceEasily strippable & very flexible Hot pressure resistantSoldering iron resistantHigh current carrying capacity Short Circuit overload upto +2800C

Siechem offers Electron Beamed XLPE Cables guaranteeing enhanced electrical, Mechanical & Thermal Properties

3332 PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 18: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Available in 20 mm, 25 mm & 32 mm. tangent & Back-outlet also available.Material: Malleable Cast IronFinish: Hot dipped galvanised (BS4568 class 4)Tapped M4/2BA screw holes at 50.5 mm centre with a M4 tapped hole in base for earthing screw.

G.I. Conduit Fitting

1 way 2 way 2 way 3 way 4 way

BESA BOX BESA BOX BESA BOX BESA BOX BESA BOX

Supplied with earth terminal

Material: Steel PlateFinish: Hot dipped galv.

Material: Cast ironFinish: Hot dipped galv.

Material: Cast ironFinish: Hot dipped galv.

Available in 20,25 &32mm Material: Steel

Finish: Hot dipped galv.(BS4568 - class 4)

Available in 20,25 &32mm Material: Steel

Finish: Hot dipped galv.(BS4568 - class 4)

S.S. KNOCKOUT BOX ADAPTABLE BOX SURFACE SWITCH BOX SOLID COUPLER BAR SADDLE

Available in 20,25 &32mm Material: Brass

Available in 20,25 &32mm Material: Brass

Available in 20,25 &32mm Material: Brass

Available in 20,25 &32mm Material: Brass

Available in 20,25 &32mm Material: Brass

REDUCER FEMALE BUSH LONG MALE BUSH STOPPING PLUG ROUND LOCKING RING

British Standard Steel ConduitType Tested By PSB

Type of KnockoutDepth (mm) Size (mm)Dimensions Dimensions

Terminal Type CItem Code Item CodeItem Code

Terminal Type B Terminal Type A

Switch Boxes

Product details

Steel Conduit

Adaptable Box with Cover & Screws

Flexible Conduitwith PVC Sheath

Conduit Bender 20mm - 32mmOption: Light Weight

Pre-Galv. Switch & Socket Knock-Out Box

Standard 1 gang switch box

Standard 2 gang switch box

Cover for switch box

Circular Solid Dies withStock & guides

G.I CONDUIT & ACCESSORIES

Class 4 Steel ConduitManufactured to BS 4568 Part 1: 1970 Class 4Hot Dipped Galvanised Inside And Outside& Thread To Bs: 4568

Normal size Ref. No Outside diametre Wall Thickness No. of length Weights (kg/m)

20 COT-C20-S-HDG 19.7 20.0 1.6±0.15 10x20 0.682 0.86225 COT-C25-S-HDG 24.6 25.0 1.6±0.15 10x15 0.860 1.09532 COT-C32-S-HDG 31.6 32.0 1.6±0.15 10x10 1.133 1.432

(mm)max. max. per bundlemin. min.

• Threaded both ends: Option: One end fitted with coupling and the other protected by plastic end cap.• Standard length of 3.75m without coupler.• Material: High quality steel ensuring smooth & easy bending.

• Widely used in different local projects and overseas markets• Manufactured to BS 4662• Made with pre-galvanised steel plate (hot-dipped galv. steel plate) (Option: steel plate and then hot-dipped galv.)• With one adjustable lug & terminal• Standard terminal

16 mm 73 x 73 H73016CT H73016BT 1Oval hole and 4 Oval KO’s

25 mm 73 x 73 H73025CT H73025BT 12 x 20mm KO’s

25 mm 73 x 130 H73225CT H73225BT 16 x 20mm KO’s

35 mm 73 x 73 H73035CT H73035BT H73035AT 7 x 20mm and 5 x 25mm KO’s

35 mm 73 x 130 H73235CT H73235BT H73235AT 11 x 20mm and 3 x 25mm KO’s

47 mm 73 x 73 H73047CT H73047BT H73047AT 10 x 20mm and 6 x 25mm KO’s

47 mm 73 x 130 H73247CT H73247BT H73247AT 12 x 20mm and 4 x 25mm KO’s

25 mm 73 x 73 + 73 x 73 H73+73CT H73+73BT 16 x 20mm KO’s

3534

COT COT

COMPLYING TO BS4568 & IEC61386APPROVED BY TUV

Supplied to Abu Dhabi International Airport,Dubai World Trade Centre, Zayed University,Meydan Residence

PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 19: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Liquid Tight Flexible Conduit IP67 and AdaptorsKSPS-IP67 Series

Item CodeMetal Tube (Bore) (approx.)

Std. PackingWP Type Adaptor* WRHD Type Adaptor*

Male Female Male FemaleThread

Inner Dia. Outer Dia.

KSPS20-IP67 3/4” 20mm 26.5mm 30M/Roll BA20M-WP BA20F-WP 20mm BA20M-WRHD BA20F-WRHD

KSPS25-IP67 1” 25mm 33.0mm 30M/Roll BA25M-WP BA25F-WP 25mm BA25M-WRHD BA25F-WRHD

KSPS32-IP67 1 1/2” 32mm 40.0mm 15M/Roll BA32M-WP BA32F-WP 32mm BA32M-WRHD BA32F-WRHD

Remark:

* All Adaptors are made of Brass with Nickel Plated.Other sizes available by order.

MaterialPre-Galvanized (Hot-Dipped Galv. Steel Tape)-IP67 Rating-Highly Flexible-Tensile Resistance-Water Resistance

WP Type Adaptor

WRHD Type Adaptor

Remark:*All Adaptors are made of Brass with Nickel Plated.*Option:1. Locknut for male adaptor.2. Male Bush (Short) for WP type adaptor.3. Male Bush (Long or Short) for WRHD type adaptor.

Liquid Tight Flexible Conduits IP67 are manufactured to:BS EN 60529-1992 and IEC 60529-2013

Item No. Inner dia.KSPS20-IP67 3/4” (20mm)KSPS25-IP67 1” (25mm)KSPS32-IP67 1 1/4” (32mm)

*Other sizes available by order

Square-locked structure made by helically coilingformed of steel strip and IP67 Rating

Steps to assemble the WP type Adaptor to the IP67 Flexible Conduit:

1. Put the Locking Ring (with insulation rubber ring inside)through the IP67 Flexible Conduit at one end.2. Put the Inner Screw into the end of IP67 Flexible Conduit.3. Put the Adaptor Body to the IP67 Flexible Conduit fixed with Inner Screw.4. Screw both the Locking Ring and Adaptor Body together tightly with two spanners.

Steps to assemble the WRHD type Adaptor to the IP67 Flexible Conduit:

1. Put the Locking Ring (with bigger insulation rubber ring inside)through the IP67 Flexible Conduit at one end.2. Put the Inner Screw into the end of IP67 Flexible Conduit.3. Put the Adaptor Body (with smaller insulation rubber ring inside) to the IP67 Flexible Conduit fixed with Inner Screw.4. Screw both the Locking Ring and Adaptor Body together tightly with two spanners.

Standard Black. Other colour on request.

Construction

IP Rating

Working Temperatures

Colour

Galvanised Steel Flexible ConduitWith PVC Coated

The highly flame retardant, low toxicity, low smoke density and Halogen free properties of the outer sheath of this product make it ideal for use in those areas where fire is of particular concern. eg. underground, tunnels, hospitals, high rise office blocks and public buildings, Electrical engineers can now specify a flexible conduit which is compatible with low Smoke cable.

Galvanised steel strips have been formed and helically wound into a flexible conduit. It is then coated with a uniform thickness of low smoke and fume PVC.

IP 65 or IP 50 with standard fittings.

Min. -200C Max. +800C

DFC 10 7X10 18 25-30-50

DFC 12 0X14 20 5-30-50

DFC 16 13X17 25 25-30-50

DFC 20 17X21 30 25-30-50

DFC 25 21X26 35 25-30

DFC 32 28X33 52 15-25

DFC 40 38X43 72 15-25

DFC 50 48X54 82 10-25

Part No. Black IDxOD Bending Radius Reeled Length mm mm mm meters

PVC Coated GI Flexible Conduits

3736

COT

COMPLYING TO IEC 61386Approved & supplied toAbu Dhabi International Airport,DEWA - Dubai Electrical & Water Authority,Julfar Twin Tower - Ras Al Khaimah.

PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 20: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

BW Cable Gland E1W Cable GlandCW Cable Gland

Cable Glands - Brass

StandardB.S. 6121, Part - 1: 1989ApplicationIndoor, For Use With All Type Of SWA CablesFunctionProvides For Armour Clamp OnlyMechanicalProvides Retention Of Armour Or Brand Impact Resistant

StandardB.S. 6121, Part - 1: 1989ApplicationOutdoor Or Indoor, For Use With All Type Of SWA CablesFunctionProvides For Armour Clamp OnlyProvides Seal On Outer Sheath Of CableMechanicalProvides Retention Of Armour Or Brand Impact Resistant

StandardB.S. 6121, Part - 1: 1989ApplicationIndoor Or Outdoor, For Use With All TypeOf SWA Extruded Bending CablesFunctionProvides For Armour Clamp Provides Seal Inner & Outer Sheath Of CableMechanicalProvides Retention Of Armour Or Brand Impact Resistant

BW Kit

P.G Gland Locknut

Locknut P.V.C ShroudEarth Tag

CW Kit

Cable Glands Pack

Cable Gland Accessories

Kit includes Brass Cable Gland,Earth Tag, Steel Locknut /Brass Locknut and PVC Shroud Kitcontains Two Sets upto 32 mm Sizes &One set for 40mm and above sizes

Material: BRASS Finish: NICKEL PLATEDSize: PG 7 to PG 48

Material: BRASS Finish: SELF FINISHEDSize: 20mm, 25mm, 32mm, 11/2”, 2

PVC Shrouds available to suit each size of Cable Gland and denoted same Gland size reference number. LSF Shrouds are also available.

Locknuts are available in Brass & Steel (Galv.) In Metric, Inches, NPT, BSP & PG Threads

Earth Tags are available from 16mm to 90mm

Bi-Metallic Terminals / Lugs & Connectors

Single & Multiple Flat Braids Female Bush

Bi-Metallic Terminal / Lugs Bi-Metallic Connector

Bi-Metallic Line Tap

Cable Terminal Ends & Connectors

Material: Copper, Aluminium, Brass, Gun Metal, Phosphorous Bronze, Galvanized Steel etc.Stds: BS, DIN, ANSI, IEC, etc.

CABLE LUGS

Bi-Metallic Earthing Connector

38 39

COMPLIES TO BS6121Approved & Supplied for Abu Dhabi International Airport, Dubai Municipality, Zayed University, Abu Dhabi.

MADE IN INDIA

Approved & Supplied for Abu Dhabi International Airport, Dubai Municipality, Zayed University, Abu Dhabi.

MADE IN INDIA

PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 21: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Conduit System

PVC CONDUIT & ACCESSORIES

Decoduct conduits are manufactured from super high impact uPVC compound suitable to withstandharsh environments. Conduits can be bent with the use of a bending spring.

DECODUCT Super high impact uPVC conduitDECODUCT uPVC conduit is available in five main typesDECODUCT Conduit FittingsDECODUCT Circular Junction BoxesDECODUCT Conduit Switch & Socket BoxesDECODUCT Conduit Fixing AccessoriesDECODUCT Conduit Cable CapacitiesDECODUCT Mini TrunkingDECODUCT Mini Trunking Switch & Socket BoxesDECODUCT Mini Trunking Cable CapacitiesDECODUCT Maxi TrunkingDECODUCT Maxi Trunking FittingsDECODUCT Maxi Trunking Cable Capacities

Heavy Gauge Round Conduit

Code Size mm Standard pcs Packs mm Mtrs DCV1 16x1.6 50 145 DCV2 20x1.8 20 58 DCV3 5x1.9 20 58 DCV4 32x2.5 10 29 DCV5 38x2.5 10 29DCV6 50X3.2 10 29

Medium Gauge Round Conduit

Code Size mm Standard pcs Packs mm Mtrs DCV1 16x1.4 50 145 DCV2 20x1.55 20 58 DCV3 5x1.8 20 58 DCV4 32x2.1 10 29 DCV5 38x2.2 10 29 DCV6 50X2.5 10 29

Light Gauge Round Conduit

Code Size mm Standard pcs Packs mm Mtrs DCV1 16x1.1 50 145 DCV2 20x1.2 20 58 DCV3 5x1.4 20 58 DCV4 32x1.5 10 29 DCV5 38x1.5 10 29 DCV6 50X1.9 10 29

Cable Terminal Ends & ConnectorsCable Tie & Marker

Cable Cleats

TWO HOLE FIXING CLEATS

TC Two Hole Cable Clamp.

The TC Two Hole Cable Clamps are a range of two hole fixing, two part cleats designed to fit cables 50 to 135mms diameter. Manufactured from high strength polypropylene and designed to be easily stacked to save time and space.Material Polypropylene / LS Zero Halogen PolypropyleneFeatures High level of UV resistance, Working temperature -35 to +1050C

ONE HOLE FIXING CLEATS

Clingstrap Cable Cleat

The Clingstrap Cable Cleat is a comprehensive range of single fixingcable cleats to provide a simple, but means of securing cables.Suitable for use with cables or pipes up to 50.8 mm in diameter.Material Polypropylene / LS Zero Halogen PolypropyleneFeatures High level of UV resistance, Working temperature -35 to +1050C

Size Cable Range Stud Hole FixingHole Cleat LSCleat Min Max Size Centers Code Code

8 46 51 M10 76 TC8 TC8LS8

9 50 57 M10 76 TC9 TC9LS

10 57 64 M10 76 TC10 TC10LS

11 64 70 M10 114 TC11 TC11LS

12 70 76 M10 114 TC12 TC12LS

14 76 85 M10 114 TC14 TC14LS

15 75 105 M10 147 TC15 TC15LS

16 105 112 M10 141 TC16 TC16LS

17 112 120 M10 141 TC17 TC17LS

18 120 128 M10 160 TC18 TC18LS

19 128 135 M10 160 TC19 TC19LS

Size Cable Range Stud Hole Cleat LS Cleat Min Max Size Centers Code

5 10.1 12.7 M6 C5 C5LS

6 12.6 15.2 M6 C6 C6LS

7 15.1 17.8 M6 C7 C7LS

8 17.7 20.3 M6 C8 C8LS

9 20.2 22.8 M6 C9 C9LS

10 22.7 25.4 M6 C10 C10LS

11 25.3 27.77 M10 C11 C11LS

12 27.6 30.5 M10 C12 C12LS

14 30.4 40.6 M10 C14 C14LS

16 35.4 40.6 M10 C16 C16LS

18 40.5 45.7 M10 C18 C18LS

20 45.6 50.8 M10 C20 C20LS

4140

Approved & Supplied toEmirates Airlines-Facilities Contracts,Abu Dhabi International Airport

PIO CABLE TIES P12 ROUND HEAD P13 RELEASABLE TIES P15 IN LINE CABLE TIESP14 IN LINE CABLE TIES P14-2 EXTRA HEAVY

P16-1 MUTABLE HEAD TIES

P16-2 STOP TIE P17-1 DOUBLE LOOPCABLE TIES

P17-2-P19 MARKERTIES

P20-1 CARD BAND P20-2PE TIES

PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 22: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Floor Boxes

Weather Protected Series - Products Floor Box

Raised Floor Access Outlet Floor Box Cross Over Bracket for Mounting

Underfloor Aluminium Trunking

SKSE-25A 3AU COVER

SKSE-40A 3PAU COVER

SBW-25A 3PPA 66 COVER

SBW-40A 3PPA66 COVER

SKSE-100A MPPA66 COVER

Water proof surface mounting accessories IP56 Cable reel series

SBW, KSE Series Aluminium Alloy Enclosure Switches

Enclosure : Aluminium AlloyCable Entries : Metric-threaded holes with membrane gland/sealing Pluge (IP54) included. When IP65 degree of protection is required compression glands must be used. Sealing plugs (IP54) are included.

Lockable : YesDegree of Protection : IP 65Negree of Protection : IncludedAuxiliary Contacts : Not includedColourEnclosure : GreyHandle : Black

Item Code: SKP 110Description: 1 Gang 1 Way SwitchStd. Pack: 1 pc

Item Code: SKP 120 Description: 1 Gang 2 Way SwitchStd. Pack: 1 pc

Item Code: SKP 210Description: 2 Gang 1 Way SwitchStd. Pack: 1 pc

Wire Specifications Length

H05VV-F 3G1.0mm2 25mm

H05VV-F 3G1.5mm2 25mm

Q/Size 61x45x39.5

Qty/Qn 4 PCS

Qty/20o 1000 PCS

Qty/40o 2000 PCS

Qty/40M 2500 PCS

SK-DXW09Overload Protection

RE430-01LED BLADE LIGHT EXIT SIGN [WHITE]

Emergency Lighting LED

R8NMLED-01 / R8MLED-01IP65 8W NON-MAINTAINED C/W LAMP, WHITEIP65 8W MAINTAINED C/W LAMP, WHITE

R8EMLED-018W LED MAINTAINED EXIT BOX

LED CHROIC10 W MODULE

4WLED LAMPS RANGE

6WLED LAMPS

T8LED TUBES

RBULKLEG R8MULK-15 R8MU-01 R8MUST-01 R8MLEDDE

RE220-012X20W HALOGEN TWIN SPOTEMERGENCY LIGHT [WHITE]

R8MTSIP65 MAINTAINED 8W BULKHEADWITH TEST SWITCH

Lamps New

R8MLED3-01+138W LED MAINTAINED EMERGENCY - RECESSED

4342 PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 23: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Rechargeable Emergency Light

RECHARGEABLEEMERGENCY LIGHT

Prestigious Clients

4544 PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 24: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Infrastructure Projects

Dubai Airport Terminal 3 & Concourse 2

New Doha International Airport

Dubai Metro

Queen Alia International Airport - Jordan

Khalifa Port Abu Dhabi

Dubai Tram

Dubai Airport Terminal 2

DWC ATC Tower

Atlantis Dubai

Burjside Boulevard

NBD

St. Regis Sadiyat

Park Hyatt Abu Dhabi

Deerfields Town Square

Crowne Plaza Dubai Festival City

The Palm JumeirahThe Old Town IslandMadinat Jumeirah

Habtoor Resorts & Spa The Address Dubai Mall

Yas MallRose Rotana Hotel

Zayed University NYU Abu Dhabi

Commercial Projects

4746 PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 25: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Viceroy Hotel Lotus Tower

Mohammed Bin Rashid City

Dream Tower

Duja Tower

Nakheel MallAl Zorah Resort

Dubai-mall-Fashion Avenue Expansion

Burj Vista

Commercial Projects

Masdar Siemens HQ

JW-Mariott-Marquis Hotel, DubaiDaman Towers

Al Badar Towers Gold & Silver Towers

EK Cargo Mega Terminal

DWTC Residence

Park Towers

Al Zenia

Abu Dhabi Financial Centre

Office & Residential Projects

4948 PRODUCTCATALOGUE

PRODUCTCATALOGUE

Page 26: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646

Jewel Of The Creek 84 Town Houses At Jumeirah Islands

Madinat-jumeirah - Phase 4

Etihad Museum

Lego Land - Dubai

Office & Residential Projects Infrastructure

50 PRODUCTCATALOGUE

Page 27: Lighting up the Middle East since 1991 - misterlight.com · Lighting up the Middle East since 1991 Cables & Accessories MRL_8 Head Office Tel: +971 4 296 3636 Fax: +971 4 296 3646