light pole base safety tower · pdf file•issues: •1-how to keep light pole base...
TRANSCRIPT
• Issues:
• 1-How to keep light pole base forms safely
secured during and after pour?
• 2-How to pour safely without standing on
top of a ladder?
• 3-How to accurately pour, to proper level,
tall forms?
ANSWER Light pole base safety tower. Five foot tall by 48” manhole base.
Flat slap top. (Obviously don’t put a block out in it). Safety railing.
Steps. Chains for securing forms.
Larger footing area compared to top of ladder. Increased efficiency
in pour times due to not having to reposition ladder for every form.
Simply just move in a circle.
Ability to see down into form and pour to proper height. Also safer
now for QC technician to do pre and post pour inspections.
Materials List
12ea 5/8x8” eye bolts
30’ 3/8 cable and 10ea 3/8 clamps
14ea 3/8 safety hooks
48’ 3/8 chain
30’ 1 ¾” steel pipe
6’ 2” steel pipe
1ea 5’x48”diameter manhole (or larger)
1ea flat slab top (no blockout), with the 2” pipe cast into top.
4-5ea steps