Date: July 4, 2019 Daniel Kravcak, PMP | Project Manager | Performance Construction 604–628–9648 office | 604–999–7915 cell 1150–21331 Gordon Way, Richmond, BC V6W 1J9 From: Keith Bell LORE ELECTRIC INC Office: 604 940 4240 Email: [email protected] #8-7218 Progress Way Delta B.C V4G 1H2 Letter of Transmittal The Basalt – In Suite fixtures and Common Corridors for approval Note the following changes: Type AA changed to Grey and 3000K Alternate Type BB added to cut sheets which was previously approved Type EE custom colour “Umbra Grey” selection has been selected Type G has been confirmed acceptable with Pennyfarthing Type L has been revised as an alternate with a remote driver located in the electrical closets Type SA revised and confirmed acceptable to Pennyfarthing Type SC revised to be SMD6R in all laundry closets and an Alternate Galaxy L650900BN010A1 in all other SC locations, this has been confirmed acceptable to Pennyfarthing Type SD and SK have been deleted as the millworker will be supplying and stalling a different fixture SH revised as per ID request SJ and SL – Satin Nickel trim added Spec added for the LED tape light shown on the ID drawings around the mailboxes The information contained in this drawing has been reviewed and is: ACCEPTABLE TO LORE ELECTRIC NOT ACCEPTABLE TO LORE ELECTRIC ACCEPTABLE AS NOTED SUBJECT TO ACCEPTANCE BY DESIGN CONSULTANT Supplier is responsible for providing acceptable products in accordance with Specifications Per: Keith Bell Date: x x 7.4.2019 SUBMITTAL REVIEW Review is for general compliance with interior design contract documents. Sole responsibility for correctness of dimensions, details, quantities and safety during fabrica- tion and installation shall remain with the contractor. NO EXCEPTIONS TAKEN FURNISH WITH CHANGES NOTES AMEND AND RESUBMIT REJECTED portico design group By Christine Bauhaus on Jul 11, 2019 DKL ONLY REVIEWED THE STEP LIGHT. NG DKL. 2019.07.29 PF MK Aug, 1.19: Reviewed as per comments below SHIFT ARCHITECTURE INC. SHOP DRAWING REVIEW Reviewed Reviewed as Noted Revise and Resubmit Not Reviewed Project Date Reviewed By This review by Shift Architecture Inc. is for the sole purpose of ascertaining conformance with the general design concept. This review shall not mean that Shift Architecture Inc. approves the detailed design inherent in the shop drawings, responsibility for which shall remain with the Contractor submitting same, and such review shall not relieve the Contractor of the responsibility for errors or omissions in the shop drawings or of the responsibility of meeting all requirements of the contract documents. The Contractor is responsible for dimensions to be confirmed and correlated at the job site, for information that pertains solely to fabrication processes or to techniques of construction and installation, and for the coordination of the work of all trades. 8/1/2019 1505 HK REVISE & RESUBMIT SC FIXTURE AS PER PENNYFARTHING COMMENTS

Upload: others

Post on 24-Jan-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Date: July 4, 2019

Daniel Kravcak, PMP | Project Manager | Performance Construction 604–628–9648 office | 604–999–7915 cell 1150–21331 Gordon Way, Richmond, BC V6W 1J9

From: Keith Bell LORE ELECTRIC INC Office: 604 940 4240 Email: [email protected] #8-7218 Progress Way Delta B.C V4G 1H2

Letter of Transmittal

The Basalt – In Suite fixtures and Common Corridors for approval Note the following changes:

Type AA changed to Grey and 3000K

Alternate Type BB added to cut sheets which was previously approved

Type EE custom colour “Umbra Grey” selection has been selected

Type G has been confirmed acceptable with Pennyfarthing

Type L has been revised as an alternate with a remote driver located in the electrical closets

Type SA revised and confirmed acceptable to Pennyfarthing

Type SC revised to be SMD6R in all laundry closets and an Alternate Galaxy L650900BN010A1 in all other SC locations, this has been confirmed acceptable to Pennyfarthing

Type SD and SK have been deleted as the millworker will be supplying and stalling a different fixture

SH revised as per ID request

SJ and SL – Satin Nickel trim added

Spec added for the LED tape light shown on the ID drawings around the mailboxes

The information contained in this drawing has been

reviewed and is:

ACCEPTABLE TO LORE ELECTRIC

NOT ACCEPTABLE TO LORE ELECTRIC

ACCEPTABLE AS NOTED

SUBJECT TO ACCEPTANCE BY DESIGN CONSULTANT

Supplier is responsible for providing acceptable products in

accordance with Specifications

Per: Keith Bell Date:

xx

7.4.2019

SUBMITTAL REVIEWReview is for general compliance with interior design contract documents. Sole responsibility for correctness of dimensions, details, quantities and safety during fabrica-tion and installation shall remain with the

contractor.

NO EXCEPTIONS TAKEN FURNISH WITH CHANGES NOTES AMEND AND RESUBMIT REJECTED

portico design group

By Christine Bauhaus on Jul 11, 2019

REVIEWED........................................(___)REVIEWED (MODIFIED)...................(___)REVISE AND RESUBMIT....................(___)NOT REVIEWED................................(___)

Reviewed only as to general conformity with thedesign concept and for general arrangement.The Consultant does not warrant or represent thatThe Consultant does not warrant or represent thatthe information contained on this shop drawing is either accurate or complete. Sole responsiblity for correct design, details and dimensions shall remain with the party submitting the drawing.

Durante Kreuk Ltd.

PER:_____________ DATE:______________

X DKL ONLY REVIEWED THE STEP LIGHT. NG DKL. 2019.07.29

PF MK Aug, 1.19: Reviewed as per comments below

SHIFT ARCHITECTURE INC.

SHOP DRAWING REVIEW

Reviewed

Reviewed as Noted

Revise and Resubmit

Not Reviewed

Project

Date

Reviewed By

This review by Shift Architecture Inc. is for the sole

purpose of ascertaining conformance with the

general design concept. This review shall not mean

that Shift Architecture Inc. approves the detailed

design inherent in the shop drawings, responsibility

for which shall remain with the Contractor

submitting same, and such review shall not relieve

the Contractor of the responsibility for errors or

omissions in the shop drawings or of the

responsibility of meeting all requirements of the

contract documents. The Contractor is responsible

for dimensions to be confirmed and correlated at the

job site, for information that pertains solely to

fabrication processes or to techniques of

construction and installation, and for the

coordination of the work of all trades.

8/1/2019

1505

HK

REVISE & RESUBMITSC FIXTURE AS PERPENNYFARTHINGCOMMENTS

Page 2: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

AA

Exterior Doors

Cooper Lighting - XTOR2B-Y

Cooper Lighting Page 1Grey Colour

Page 3: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

AA

Cooper Lighting - XTOR2B-Y pg2

Cooper Lighting Page 2

Page 4: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

BB

Galaxy Lighting - L223480BK-HSG

Galaxy Lighting Page 3

REVIEWED........................................(___)REVIEWED (MODIFIED)...................(___)REVISE AND RESUBMIT....................(___)NOT REVIEWED................................(___)

Reviewed only as to general conformity with thedesign concept and for general arrangement.The Consultant does not warrant or represent thatThe Consultant does not warrant or represent thatthe information contained on this shop drawing is either accurate or complete. Sole responsiblity for correct design, details and dimensions shall remain with the party submitting the drawing.

Durante Kreuk Ltd.

PER:_____________ DATE:______________

X

2019/07/29

Page 5: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

BB

Galaxy Lighting - L223481BK0830

Galaxy Lighting Page 4

REVIEWED........................................(___)REVIEWED (MODIFIED)...................(___)REVISE AND RESUBMIT....................(___)NOT REVIEWED................................(___)

Reviewed only as to general conformity with thedesign concept and for general arrangement.The Consultant does not warrant or represent thatThe Consultant does not warrant or represent thatthe information contained on this shop drawing is either accurate or complete. Sole responsiblity for correct design, details and dimensions shall remain with the party submitting the drawing.

Durante Kreuk Ltd.

PER:_____________ DATE:______________

X

2019/07/29

Page 6: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

DD

Lobby Ext entry

Kirlin - LRR-04006-1500L-120-

30K-MFL

Kirlin Page 5

Page 7: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

DD

Kirlin - LRR-04006-1500L-120-

30K-MFL pg2

Kirlin Page 6

Page 8: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

EE

Parkade Entrance

US Architectural Lighting - 8630-

16LED-WW-120-RAL7004-T

US Architectural Lighting Page 7

Page 9: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

EE

US Architectural Lighting - 8630-

16LED-WW-120-RAL7004-T pg2

US Architectural Lighting Page 8

RAL-7022

Page 10: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

E

Stairwell

MAC'S II Agencies - STR12-D-30-

LED-40-1-S-MSW

MAC'S II Agencies Page 9

Page 11: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

E

MAC'S II Agencies - STR12-D-30-

LED-40-1-S-MSW pg.2

MAC'S II Agencies Page 10

Page 12: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

E

MAC'S II Agencies - STR12-D-30-

LED-40-1-S-MSW pg.3

MAC'S II Agencies Page 11

Page 13: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

G

Corridor

Halo - SMD6R6930WH

Halo Page 12

SUBMITTAL REVIEWReview is for general compliance with interior design contract documents. Sole responsibility for correctness of dimensions, details, quantities and safety during fabrica-tion and installation shall remain with the

contractor.

NO EXCEPTIONS TAKEN FURNISH WITH CHANGES NOTES AMEND AND RESUBMIT REJECTED

portico design group

By Christine Bauhaus on Jul 11, 2019

Page 14: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

G

Halo - SMD6R6930WH pg.2

Halo Page 13

Page 15: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

L

Suite Entry

DALS Lighting Inc. - 4001-SN

DALS Lighting Inc. Page 14

SUBMITTAL REVIEWReview is for general compliance with interior design contract documents. Sole responsibility for correctness of dimensions, details, quantities and safety during fabrica-tion and installation shall remain with the

contractor.

NO EXCEPTIONS TAKEN FURNISH WITH CHANGES NOTES AMEND AND RESUBMIT REJECTED

portico design group

By Christine Bauhaus on Jul 11, 2019

Page 16: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

L

DALS Lighting Inc. -

BT12DIMLED-IC

DALS Lighting Inc. Page 15

Page 17: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SB

Shower

Liteline - SLM4-30-WH

Liteline Page 19

& SA

& Thoughout

SUBMITTAL REVIEWReview is for general compliance with interior design contract documents. Sole responsibility for correctness of dimensions, details, quantities and safety during fabrica-tion and installation shall remain with the

contractor.

NO EXCEPTIONS TAKEN FURNISH WITH CHANGES NOTES AMEND AND RESUBMIT REJECTED

portico design group

By Christine Bauhaus on Jul 11, 2019

Page 18: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SB

Liteline - P-4020

Liteline Page 20

& SA

Page 19: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SC

Throughout

Halo - SMD6R12930WH

Halo Page 21

xxxxxxxxxx Laundry

in Laundry

Page 20: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SC

Halo - SMD6R12930WH pg.2

Halo Page 22

Laundry room only

Page 21: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

L650900BN010A1

12"D x 3-1/2"H

LED Flush Mount Ceiling Light - in Brushed Nickel finish with White Acrylic Lens

Specifications Model#: L650900BN010A1 UPC: 772775266805Finish: Brushed Nickel Location: DryGlass/Shade: White Acrylic Lens with Brushed

Nickel TrimsENERGY STAR: Yes

Fixture Material: Steel & Acrylic Lens Fluorescent: NoDimension: 12"D x 3-1/2"H Safety Listings: CSA or EquivalentLamping: 12W LED, Unit Gross Weight: 2.42 lbs.Color Temperature/CRI: 3000K / 80 Master Pack: 6Lamp Included: Included Master Gross Weight: 16.06 lbs.Dimming: Optional

Total Lumens: 1140 lumens Delivered Lumens: 912 lumensComments: For other color temperatures, dimming and voltage options, please consult factory.

Excel Lighting & Manufacturing13611 Maycrest Way, Richmond, BC Canada V6V 2J4 | Tel:604-278-8881 or 604-278-1919 | Fax:604-278-2551 | e-mail:[email protected]

55 East Beaver Creek Road, Unit A, Richmond Hill, ON Canada L4B 1E5 | Tel:905-889-8787 | Fax:905-763-8778 | e-mail:[email protected]

TYPE - SC Location - ALL SC locations other then the Laundry room Part Number - L650900BN010A1

original fixture was all fabric. There is no brushed nickel in the space. Plumbing and other lighting is Chrome - PDG

PF MK: Revise to L613532CH016A1 as discussed

Page 22: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SF

Dining

Arlington Industries Inc - CP3540

Arlington Industries Inc Page 26

SUBMITTAL REVIEWReview is for general compliance with interior design contract documents. Sole responsibility for correctness of dimensions, details, quantities and safety during fabrica-tion and installation shall remain with the

contractor.

NO EXCEPTIONS TAKEN FURNISH WITH CHANGES NOTES AMEND AND RESUBMIT REJECTED

portico design group

By Christine Bauhaus on Jul 11, 2019

Page 23: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SH

Vanity

Kuzco - WS8424-CH

Kuzco Page 27

SUBMITTAL REVIEWReview is for general compliance with interior design contract documents. Sole responsibility for correctness of dimensions, details, quantities and safety during fabrica-tion and installation shall remain with the

contractor.

NO EXCEPTIONS TAKEN FURNISH WITH CHANGES NOTES AMEND AND RESUBMIT REJECTED

portico design group

By Christine Bauhaus on Jul 11, 2019

Page 24: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SJ

Exterior Deck

Halo - SMD6R12930WH

Halo Page 28

Page 25: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SJ

Halo - SMD6R12930WH pg.2

Halo Page 29

Page 26: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SJ

Halo - SMD6R12930WH pg.3

Halo Page 30

Page 27: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SJ

Halo - SMD6R12930WH pg.4

Halo Page 31

Page 28: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SL

Exterior Deck

Halo - SMD6R12930WH

Halo Page 32

Page 29: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SL

Halo - SMD6R12930WH pg.2

Halo Page 33

Page 30: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SL

Halo - SMD6R12930WH pg.3

Halo Page 34

Page 31: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Project: Basalt

Type:

Location:

Fixture:

Lamping:

SL

Halo - SMD6R12930WH pg.4

Halo Page 35

Page 32: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

Conforms to ANSI/UL Standard 2108Certified to CAN/CSA Standard C22.2 No. 250.0

ULLISTED

C USR

24O

PRODUCT FEATURES• 90+ CRI

• Dimmable

• 50,000 hour life

• 5-year warranty

• UL-listed for indoor and outdoor use

• 3M™ industrial adhesive backing

• For use with 24V power supplies

TOTAL WATTAGE USED AT EACH LENGTH1ft 2ft 3ft 4ft 5ft 6ft 7ft 8ft 9ft 10ft 11ft 12ft 13ft 14ft 15ft2.1 5.2 8.2 9.6 12.4 14.4 17.2 18.7 21.6 23 25.8 26.9 29.7 31.5 33.8

16ft 17ft 18ft 19ft 20ft 21ft 22ft 23ft 24ft 25ft 26ft 27ft 28ft 29ft 30ft35.1 37.1 38 40.7 41.9 43.9 46.6 47.7 49.9 50.7 52.4 54.2 55.6 57.5 57.8

SPECIFICATIONS

Series PL - Performance 200 (Outdoor)

Input Voltage 24V DC / Constant Voltage

Watts per Foot 1.9W/ft @ Maximum Run Length

Max Run Length Unlimited, power every 30ft

Production Intervals 2-5/8" (66.7mm)

End Cap Dimensions 1/2" (12.2mm) x 3/8" (9mm)

Tape Dimensions 7/16" (11.2mm) x 1/4"(6mm)

CRI 90+

Diode Epistar 2835

Dimming Options PWM, Triac, 0-10V, DMX, Hi-lume

Temp Range -40°F (-40°C) to 149°F (65°C)

Beam Spread 120°

PL27K-WR-24V

2700K148 lm/ft

IP67

PL3K-WR-24V

3000K169 lm/ft

IP67

PL35K-WR-24V

3500K176 lm/ft

IP67

PL41K-WR-24V

4100K184 lm/ft

IP67

PL5K-WR-24V

5000K195 lm/ft

IP67

KELVIN COLOR TEMPERATURE SCALE

2,00

0K

2,40

0K

2,70

0K

5,00

0K

6,00

0K

3,00

0K

3,50

0K

4,10

0K

Cut Intervals: 66.7mm (2-5/8")

151

+

_DC24V

++

__DC24V

151DC24V

++

__DC24V

131

131

131

131

Kelvin Lumens Rating

MODEL:

Questions/Support | 800-789-3810 | [email protected] 042219DM

Fixture Type:

Project:

Location:

Width: 11.2mm(12.2mm end cap)

Depth: 6mm(9 mm endcap)

PL-SERIES | RUBBER COATED | LINEAR LED LIGHTING

PERFORMANCE 200 (OUTDOOR)

TITLE 24JA8-2016

Supports

Compliance

Page 33: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

092818DMQuestions/Support | 800-789-3810 | [email protected]

Fixture Type:

Project:

Location:

ULV3636 WATT —24 VOLT | CLASS 2 SUPPLY

SPECIFICATIONSModel ULV36

Input Voltage 100 – 277 VAC

Output Voltage 24 VDC / Constant Voltage

Max. Wattage 36 W

Temp Range -20 °F – 158 °F

Dimensions W × H × D 4-1/2" × 2-5/16" × 1-3/8"

Classification Class 2

PRODUCT FEATURES

• 431 Hz / Flicker-free Dimming Down to 5%

• Incandescent, ELV, MLV, or 0-10 V Dimming

• Protections: Short Circuit / Over Current / Over Voltage

• Free Air Convection Cooling

• Suitable for Dry / Damp Location

• UL-Listed Class 2

Conforms to ANSI/UL Standard 2108

Certified tp CAN/CSA Standard C22.2 No. 250.0

CLASS2

1-3/8"

2-5/16"

4-1/2"

7/8"

3-1/16"1-5/8"

Mailbox ID tape Light

BASALT

Mailbox ID tape light

Page 34: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

092818DMQuestions/Support | 800-789-3810 | [email protected]

ULV3636 WATT —24 VOLT | CLASS 2 SUPPLY

SPECIFICATION Parameters Symbols Test Conditions / Comment Min Typ Max Units

INPUTInput Voltage VIN 108 305 VAC

Rated Input Voltage VIN RATEDPhase Cut Dimming 120 VAC

No Phase Cut Dimming 120 277 VACInput Frequency fline 47 50 / 60 63 Hz

Input Current IIN

Full Load,VIN = 120 VAC 0.40 AFull Load,VIN = 230 VAC 0.20 AFull Load,VIN = 277 VAC 0.18 A

GENERAL CHARACTERISTICS

Power Factor PF30% – 100% Load, VIN = 120 VAC 0.95 PF50% – 100% Load, VIN = 230 VAC 0.9 PF70% – 100% Load, VIN = 277 VAC 0.9 PF

Total Harmonic Distortion THD

30% – 100% Load, VIN = 120 VAC 20 %50% – 100% Load, VIN = 230 VAC 20 %

70% – 100% Load, VIN = 277 VAC 20 %

Efficiency ηFull Load, VIN = 120 VAC 82 83 %Full Load, VIN = 230 VAC 83 83.5 %Full Load, VIN = 277 VAC 83 83.5 %

Turn On Delay Time Ton_delay Cold Start, No Dimmer 0.3 0.5 S

Leakage Current ILeakage VIN = 277 VAC / 60Hz 0.5 mAOUTPUT

Output Voltage VOUT No Dimming 22.8 24 24.7 VOutput Current IOUT 0 1500 mALine Regulation IOUT-LINE 1 %Load Regulation IOUT-LOAD 1 %Ripple Voltage IOUT-RIPPLE Full Load, (pk-to-pk) / (2 × Average) 10 %Output Voltage

Overshoot IOVERSHOOT Power ON 5 %

0-10V OR RESISTOR DIMMINGThe 0-10 V or resistor dimming is a dimming manner that can be used to dim the output voltage via a standard commercial wall dimmer (0-10 VDC) or an external control voltage source (0-10 VDC) or external resistor.

The dimming range is 100 % VOUT to 5 % VOUT. When VDIM is 8-10 VDC, the output voltage maintains 100% VOUT, and when VDIM is below 0.6 V, the output voltage is 5% VOUT.Absolute Maximum

Voltage on 0-10 V Pin

VDIM -2 15 V

Source Current on 0-10 V

Dimming PinIDIM 100 uA

VDIM Voltage for Full Bright VDIM-MAX 8 V

Output Duty Cycle D0-10V PWM Output 5 100 %

MODEL LIST Model Name Rated Input Voltage Rated Output Power Rated Output Voltage Output Current Note

ULV36120–277 VAC

36 W 24 VDC 0-1500 mA × 2120 VAC (Phase Cut Dimming)

Mailbox ID drawing Tape light

Page 35: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

092818DMQuestions/Support | 800-789-3810 | [email protected]

SPECIFICATION (CONT.) Parameters Symbols Test Conditions / Comment Min Typ Max Units

PWM DIMMINGThe PWM dimming is a dimming manner that can be used to dim the output voltage via the duty cycle of PWM signal.

The dimming range is 100 % VOUT to 5 % VOUT. When the duty cycle is 80 % to 100 %, the output voltage reaches 100 % VOUT, and the output voltage maintains 5 % VOUT when the duty cycle below 6 %.

PWM Frequency fPWM 0.1 1 KHzHigh Level Voltage

of PWM Signal VPWM-High 8 10 12 V

Lower Level Voltage of

PWM SignalVPWM-Low 0 1 V

Output Duty Cycle DPWM PWM Output 5 100 %TRIAC DIMMINGThe unit is compatible with leading-edge and trailing-edge dimmer.

Input Voltage VIN-TRIAC DIM 120 VACOutput Duty Cycle DTRIAC PWM Output 0 - 100 %

Suggest Load Range PSuggest VIN = 120 VAC 5 36 W

PROTECTIONOver Voltage Protection VOVP Latch Off Mode 30 V

Over Temperature Protection TOTP

If the case temperature exceeds OTP point, the output voltage of the driver is

automatically reduced.100 105 110 ℃

Short Circuit Protection It will recover automatically after fault conditions is removed.

ENVIRONMENTStorage

Temperature TStorage Humidity: 5 % RH to 95 % RH -40 - +85 ℃

Operating Relative Humidity Ha Non Condensing 10 90 %

OTHERSLife Time TLife Full Load, 120 VAC Input, 50 ℃

Case Temperature50 kHrs

MTBF TMTBF 200 kHrsDimension L × W × H 68 mm × 40 mm × 26 mm (2.68" × 1.57" × 1.02")

SAFETY COMPLIANCEUL Listed UL8750 Compliance to UL1310 Class 2, CSA-C22.2 No. 107.1

EMC COMPLIANCEFCC Part 15B Conducted Emission Test and Radiated Emission Test

Note: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 ℃ and VIN = 100 – 277 VAC.

ULV3636 WATT —24 VOLT | CLASS 2 SUPPLY

Mailbox ID Drawing Tape light

Page 36: Letter of Transmittalperfcon.net/drawings/1296basalt/Shop Drawings/190801 1505... · 2019-08-01 · 1150–21331 Gordon Way, Richmond, BC V6W 1J9 #8 From: Keith Bell LORE ELECTRIC

092818DMQuestions/Support | 800-789-3810 | [email protected]

TYPICAL APPLICATIONPRIMARY SIDE DIMMING (120V ONLY)

SECONDARY SIDE DIMMING (120–277V)

SECONDARY SIDE DIMMING (0–10V)

SECONDARY SIDE DIMMING (DMX)

DIM + (VLT)DIM - (GRY)

OUTPUT

LED - (RED)

LED + (BLU)

INPUT

ACL (BLK)

ACL (WHI)

VIOLET (DIM+)

GRAY (DIM+)

DIM + (VLT)DIM - (GRY)

OUTPUT

LED - (RED)

LED + (BLU)

INPUT

ACL (BLK)

ACL (WHI)

VIOLET (DIM+)

GRAY (DIM+)

DIM + (VLT)DIM - (GRY)

OUTPUT

LED - (RED)

LED + (BLU)

INPUT

ACL (BLK)

ACL (WHI)

VIOLET (DIM+)

GRAY (DIM+)

DIM + (VLT)DIM - (GRY)

OUTPUT

LED - (RED)

LED + (BLU)

INPUT

ACL (BLK)

ACL (WHI)

VIOLET (DIM+)

GRAY (DIM+)

ULV3636 WATT —24 VOLT | CLASS 2 SUPPLY