L21–MagneticLevelIndicator
Floatmagneticlevelmeterforcontinuouslevelmeasurementofliquids
‐ Remote data transmission
‐ Use in potentially explosive atmospheres
‐ Robust and versatile design
‐ Reasonable price
Measurement and Regulation
www.emkometer.com
Page 2 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
ContentL21 – Magnetic Level Indicator ............................................................................................................................... 1
Description ......................................................................................................................................................... 4
Principle of operation ......................................................................................................................................... 5
A Basic configuration ............................................................................................................................................ 7
A1 L21 for applications up to PN63 .................................................................................................................. 8
A2 L21 for applications up to PN100 ................................................................................................................ 9
A3 L21 for applications up to PN160 .............................................................................................................. 10
A4 L21 for applications up to PN250 .............................................................................................................. 11
A5 L21 for applications up to PN400 .............................................................................................................. 12
A6 L21 with double connection ...................................................................................................................... 13
A7 L21 with polymeric coating (ETFE, PE, PFA, PTFE) ..................................................................................... 14
A8 L21 combined chamber for easier transport and installation ................................................................... 15
A9 L21 plastic version (PVDF / PP / PVC) up to PN16 ..................................................................................... 16
A10 L21 with bypass chamber for measurement and sampling .................................................................... 17
A11 L21 with chamber for independent transmitters and other level sensors ............................................. 18
A12 L21 with extended chamber for independent transmitters and other level sensors ............................. 19
A13 L21 with extended chamber for dirty fluid, sticky products or liquefied gases ...................................... 20
A14 L21 chamber for level switch located above ........................................................................................... 21
A15 L21 conductivity probes for level indication / float switches .................................................................. 22
A16 L21/C magnetic level indicator for containers ........................................................................................ 23
A17 L21 with optional mounting attachment ................................................................................................ 24
A18 L21 with an additional chamber for the compensator weight float ....................................................... 25
A19 L21/4 top‐mounted level indicator ......................................................................................................... 26
Example of use of level indicator ‐ connection options ................................................................................... 26
A19 L21/4 top‐mounted level indicator ......................................................................................................... 27
A20 L21/4 top‐mounted level indicator for low density / high pressure ....................................................... 28
A21 L21/3 with a float on a string .................................................................................................................. 29
A22 L21/5 buoyancy level indicator ............................................................................................................... 30
B Advanced configuration ................................................................................................................................... 31
B1 Float for bypass level indicator L21 ........................................................................................................... 32
Float dimensions and dependence on the density .......................................................................................... 32
B2 Standard options for top of chamber ........................................................................................................ 33
B3 Standard options for bottom of chamber ................................................................................................. 34
B4 Orientation of process connection ............................................................................................................ 35
Measurement and Regulation
www.emkometer.com
Page 3 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
B5 Process connection type............................................................................................................................ 36
B6 Magnetic roller indicator ........................................................................................................................... 37
B7 Stainless steel scale ................................................................................................................................... 38
B8 Connecting option ..................................................................................................................................... 39
C Accessories ....................................................................................................................................................... 40
C1 SPJ Limit switch.......................................................................................................................................... 41
C2 Potentiometric level sensor SP4 ................................................................................................................ 43
C3 Potentiometric level sensor SP4 in Ex d execution .................................................................................... 44
C4 Magnetostrictive level sensor SP4/M ........................................................................................................ 46
C5 EMKOTDR‐60 Radar level meters with guided wave ................................................................................. 48
C6 EMKOCAP‐25 Capacitive level meters ....................................................................................................... 49
EMKOCAP‐26 Capacitive level meters .............................................................................................................. 49
C7 Thermal insulation ..................................................................................................................................... 50
C8 Electrical heating with thermal insulation OE ........................................................................................... 51
C9 Heating jacket (steam, water) with insulation .......................................................................................... 52
C10 Signal transducers of level or temperature ............................................................................................. 53
L21 Manufacturer type number ..................................................................................................................... 54
Ordering ........................................................................................................................................................... 55
Appendix 1 ....................................................................................................................................................... 56
Appendix 2 ....................................................................................................................................................... 57
Appendix 3 ....................................................................................................................................................... 58
Appendix 4 ....................................................................................................................................................... 59
Appendix 5 ....................................................................................................................................................... 60
Appendix 6 ....................................................................................................................................................... 61
Measurement and Regulation
www.emkometer.com
Page 4 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
Description The sensor type L21 is used to measure l emkotdr evels or interface of fluids in both open and pressurized tanks.
It can also be used in applications with the formation of foam or aerosol, where contactless measurement
methods fail.
Body material of these level gauges is high quality stainless steel or chemically resistant materials. Local
measurement is independent from external electrical supply which allows measurement of flammable,
chemically corrosive and toxic substances also in very difficult conditions, such as high process temperatures and
pressures.
On the customer's request indicator can be equipped with limit switches that allow remote monitoring of
minimum or maximum level of liquid in the tank, control of pumps, opening or closing valves, etc.
It can also be equipped with a continuous sensor with 4 ‐ 20 mA current output for exact monitoring of the level
in the tank remotely. Several optional digital communication protocols are available such as HART, Foundation
FIELDBUS, PROFIBUS etc. There are several options of transmitters including reed chain, magnetostrictive,
capacitive and radar principles.
Mechanical local indication can be extended by a range of displays. All the devices are available for potentially
explosive atmospheres with ATEX certificates. For easy draining (venting) there is screwed plug optionally
accompanied by a valve.
Local indicator is available in the following two options:
Glass tube in which a level indicator moves tracking magnet
Rolling magnetic rollers in the bar, changing color according to the level (white ‐ red).
For extreme temperature conditions it can be equipped with insulated tube, steam or electric heating of the measuring tube. Several insulation options are available according to the process conditions.
L21 is a very complex product and there are many choices that are not published here. Please contact your local distributor or factory in case of any specific requests or questions.
Productfeatures
Simple, robust and proven stainless steel design
Ability to make parts in contact with the medium of PP, PVDF, PVC, Hastelloy or other materials in case of corrosive substances
Stable local indication without need of power supply
Pressure resistant and gas‐tight separation of the medium and indicators
Easy installation of the accessories using the mounting rails (limit contacts, display outputs, scales)
Indicators including limit switches and continuous outputs can be replaced without draining the tank
Insulated, steam or electric heated options available. Interface measurement is possible as well
In comparison with direct gauges it has lower risk of leaks and clearer local indication
The device is approved for use in potentially explosive atmospheres of pressure vessels and boilers
Device is designed and pressure tested according to the customers’ needs including temperatures from ‐196°C up to 525°C
Device is manufactured with accordance to PED 97/23/ES and corresponding standards
Each device is pressure tested and verified. Calibration and strict functional tests are also performed on every device at the factory
Measurement and Regulation
www.emkometer.com
Page 5 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
Principleofoperation The sensor is connected via flanges or threaded connections in a vertical position to the side of the tank, in which
level or interface of the liquid should be monitored. It works on the principle of connected vessels. There is sealed
bypass chamber with a float inside. Float has a built‐in permanent magnet and follows the level of liquid in the
observed tank. Local indicator as well as additional sensors are magnetically coupled to the float. As the float
changes its position, magnetic rollers follow it changing their orientation and thus the color (from white to red)
indication current level directly. Similarly, shuttle follower indicates the level. If requested, device can be
equipped with stainless steel scale in chosen units of length, volume, percentage etc.
Float is specifically designed, manufactured and tested for requested conditions of use. Double pole magnetic
system is used to create uniform and strong 360° magnetic field. Magnetic system has a high gauss rating
providing large safety zone for long term service taking in count effects of ageing of the magnets over time.
Basic analogue output is based on the reed chain. Reed switches together with a network of resistors form three
wire potentiometric circuit. The resistance between one pole and the “wiper” (here represented by the magnet
in the float) is proportional to the level in the tank. Resistance is converted using the transducer to the standard
analog signal 4 (0) to 20 mA for further processing, or advanced transducers can be used for digital
communication such as HART, FOUNDATION FIELDBUS, PROFIBUS, Modbus, RS‐485 and others.
More advanced methods of position sensing include capacitive, guided radar and magnetostrictive principles.
Detailed information is available upon request in separated datasheets.
Similarly, it is possible to use a magnetic switch as a limit sensor to indicate the minimum, maximum or other
selected position level in the tank. Permanent magnet in the float in this case activates the reed contact (or
moves a cam that activates a micro switch in SPM version). Based on the rating of the switch it can be used
directly to perform some desired function or the signal can be amplified or processed in the control system.
This solution is fully comparable with the semiconductor sensing elements in the terms of reliability and
precision. SIL 2 certificate is available for selected configurations. Reliability indicators are available upon request.
Local indication Float
Medium
Measurement and Regulation
www.emkometer.com
Page 6 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
Plug G1/2”
Process connection (flange, thread, pipe
for welding, special) standardized or
custom
Scale, durable laser
marked high quality
stainless steel
Indication plate allowing
custom marking (TAG)
Shut‐off valve either welded or flanged
(on picture) allows maintenance without
need to empty tank
Level indication rail is always
made from durable glass and
aluminium with several types of
rollers
Drain plug / valve
Float chamber manufactured according to
the strict standards and codes including EN
13445, 12952, PED 97/23, ASME, NACE etc.
Level sensor type SP4 for continuous
level measurement (4‐20 mA, HART,
Foundation Fieldbus, Modbus,
resistance)
Limit switch type SPJ
Ground clamp for ex application
Upper flange enables easy
maintenance even in difficult
condition, e.g. limited space under
lower process connection
User friendly flanges with hex screws for
best weight / performance ratio and
easy maintenance
Measurement and Regulation
www.emkometer.com
Page 7 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
ABasicconfiguration
Measurement and Regulation
www.emkometer.com
Page 8 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A1L21forapplicationsuptoPN63
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 63 bar g
Density of the medium ≥365 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
60,3 х 2,6 mm
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 9 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A2L21forapplicationsuptoPN100
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 100 bar g
Density of the medium ≥500 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
63,5 х 3,5 mm
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type list C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 10 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A3L21forapplicationsuptoPN160
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 160 bar g
Density of the medium ≥500 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
73,03 х 5,16 mm
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 11 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A4L21forapplicationsuptoPN250
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 250 bar g
Density of the medium ≥500 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
71 х 7,5 mm
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 12 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A5L21forapplicationsuptoPN400
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 400 bar g
Density of the medium ≥500 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
76 х 10 mm
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 13 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A6L21withdoubleconnection
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 400 bar g
Density of the medium ≥365 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
According to pressure and temperature
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 14 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A7L21withpolymericcoating(ETFE,PE,PFA,PTFE)Standardspecifications
Medium temperature
From ‐100°C to +250°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 16 bar g
Density of the medium ≥590 kg/сm3
External material of the bypass chamber and flanges
Stainless steel Lining ETFE, PE, PFA, PTFE
Diameter of the external chamber
70 х 2 mm
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
We recommend ETFE. The most
advanced method of lining
Measurement and Regulation
www.emkometer.com
Page 15 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A8L21combinedchamberforeasiertransportandinstallation
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 400 bar g
Density of the medium ≥365 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
According to pressure and temperature
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 16 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A9L21plasticversion(PVDF/PP/PVC)uptoPN16
Standardspecifications
Medium temperature
PVDF from ‐10°C to +110°C PP from ‐10°C to +80°C PVC from ‐10°C to +80°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 16 bar g
Density of the medium ≥640 kg/сm3
External material of the bypass chamber and flanges
PVDF, PP, PVC
Diameter of the external chamber
63 х 3,5 mm
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 17 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A10L21withbypasschamberformeasurementandsampling
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 400 bar g
Density of the medium ≥640 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
Based on request
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 18 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A11 L21with chamber for independent transmitters andotherlevelsensors
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 400 bar g
Density of the medium ≥365 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
Based on request
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Transmitter / level sensor
Capacitive ‐ EMKOCAP‐25, 26 Guided radar wave – EMKOTDR‐60 For details see type lists C5, C6
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 19 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A12 L21 with extended chamber for independenttransmittersandotherlevelsensors
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 400 bar g
Density of the medium ≥365 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
According to pressure and temperature
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Transmitter / level sensor
Capacitive ‐ EMKOCAP‐25, 26 Guided radar wave – EMKOTDR‐60 For details see type lists C5, C6
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 20 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A13 L21 with extended chamber for dirty fluid, stickyproductsorliquefiedgases
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 400 bar g
Density of the medium ≥365 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
88,9 x 2,6; 100 x 10
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 21 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A14L21chamberforlevelswitchlocatedabove
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 400 bar g
Density of the medium ≥365 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
According to pressure and temperature
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M, L21/5 For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 22 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A15L21conductivityprobesforlevelindication/floatswitches
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 400 bar g
Density of the medium ≥320 kg/сm3
≥500 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
According to pressure and temperature
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 23 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A16L21/Cmagneticlevelindicatorforcontainers
Standardspecifications
Medium Liquids and liquefied gases Density ≥400 kg/сm3
Measurement range (one segment)
Stainless steel/plastic Standard 0.3 to 6.0 m On request 0.3 to 9.0 m
Accuracy Repeatability The maximum level change rate
± 5 mm ± 5 mm 1 m/s
Maximum pressure standard stainless steel 4 MPa, on request 40 MPa
Fluid temperature Standard stainless steel ‐30 to +200°C Optional stainless steel ‐196 to +525°C
Process connection
Flanges: EN 1092‐1 DN 15 to DN 50, PN 6 to PN 400, ASME B16.5, DIN, ГОСТ Thread: ½ "‐ ¾" NPT, G ½ "‐ ¾" Smooth pipe for welding (others on request)
Material (parts in contact with fluid)
DIN 1.4541 stainless steel (DIN 1.4571, 1.4301, 1.4404), Hastelloy, PVC, PP, PVDF, other on request
Mounting position Vertical (side, bottom, top)
Roller indicator without scale
Roller indicator with scale in selected units (m, m3, %...)
Local display Glass tube with a magnet without scale
Glass tube with a magnet with scale in selected units (m, m3, %...)
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 24 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A17L21withoptionalmountingattachment
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 400 bar g
Density of the medium ≥400 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
According to pressure and temperature
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 25 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A18 L21with an additional chamber for the compensatorweightfloat
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 400 bar g
Density of the medium ≥350 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
According to pressure and temperature
Measurement range Up to 9000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Bottom of chamber, drain
Flat, semi‐circular bottom, flange, plug, valve, fittings For details see type list B3
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 26 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A19L21/4top‐mountedlevelindicator
Exampleofuseoflevelindicator‐connectionoptions Some conditions make difficult to use the float inside of the chamber. These conditions are for example too viscous substances, low density or intense formation of deposits. In these cases it is possible to use the version with a float outside of the chamber, connected to the gauge either by the string or by the rod.
These variants are marked:
L21/3 ‐ with a float on a string
L21/4 ‐ with a float on a rod
L21
L21/4
L21/4
L21/3
Measurement and Regulation
www.emkometer.com
Page 27 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A19L21/4top‐mountedlevelindicator
Standardspecifications
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 40 bar g
Density of the medium ≥350 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel, PP, PVDF
Diameter of the external chamber
According to pressure and temperature
Measurement range From 3000 to 6000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 28 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A20L21/4top‐mountedlevelindicatorforlowdensity/highpressure
Standardspecification
Medium temperature
From ‐196°C to +500°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 16 … 100 bar g
Density of the medium ≥300 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
60,3 x 2,6 mm; 63,5 x 3,5 mm
Measurement range From 4000 to 6000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Magnetic roller indicator
Plastic, metal, custom rollers, indicator with traverse magnet, acrylic console For details see type list B6
Scale mm, cm, %, optional For details see type list B7
Limit switch SPJ ‐ NAMUR, SPDT, min, max For details see type list C1
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M For details see type lists C2, C3, C4
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI For details see type lists C7, C8, C9
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 29 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A21L21/3withafloatonastring
Standardspecification
Medium temperature
From ‐60°C to +450°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 300 bar g
Density of the medium ≥600 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
According to pressure and temperature
Measurement range From 100 to 10000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Magnetic roller indicator Local indication by pointer
Scale mm, cm, %, optional
Limit switch SPJ ‐ NAMUR, SPDT, min, max
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 30 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
A22L21/5buoyancylevelindicator
Standardspecification
Medium temperature
From ‐60°C to +450°C
Ambient temperature
From ‐60°C to +85°C
Nominal pressure From ‐1 to 300 bar g
Density of the medium ≥600 kg/сm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the external chamber
According to pressure and temperature
Measurement range From 100 to 10000 mm
Process connection
Flanges: EN 1092‐1, DIN 2526, ANSI/ASME B16.5, ГОСТ 12815‐80, ГОСТ Р 54432‐ 2011 Thread: metric, cylindrical tube (G), conical (NPT, R); tubes for welding For details see type lists B4, B5
Top of chamber, vent Flat, semi‐circular top, flange, plug, valve, fittings For details see type list B2
Magnetic roller indicator Local indication by pointer
Scale mm, cm, %, optional
Limit switch SPJ ‐ NAMUR, SPDT, min, max
Electrical output SP4 ‐ 4‐20 mA, HART, FIELDBUS, PROFIBUS, SP4/M
Insulation / heating OE, OP, OPTA, OPTB, AFI, SAI, SCI, PI
Other specifications on request
Measurement and Regulation
www.emkometer.com
Page 31 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
BAdvancedconfiguration
Measurement and Regulation
www.emkometer.com
Page 32 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
B1FloatforbypasslevelindicatorL21
Floatdimensionsanddependenceonthedensity
The float type, its length and diameter are chosen according to specific media parameters and operating conditions. The float has the same serial number as magnetic level indicator. For illustration we present a table of dimensions for selected densities in the most widely used type of float (stainless steel, Ø50 mm, PN16).
Float length (mm) Medium density (kg/m3)
1010 400
515 500
361 600
287 700
243 800
213 900
191 1000
176 1100
164 1200
Changes of the operating conditions (temperature, pressure, density) causes shift of the measuring edge, depending on the density of the liquid. If we know the density we can correct it by moving the scale and sensors. Optionally it is possible the float for different densities supply with weight. Float material: Stainless steel DIN 1.4541, DIN 1.4571, titanium, PP, PVC, PTFE, full‐composite design. Materials magnetic coupling: samarium‐cobalt, neodymium‐boron. They are powerful magnetic materials. We use AlNiCo material for high temperature. Maximum float speed at which is a local indicator function is up to 1,5 m/s.
Medium temperature
From ‐196°C to +500°C
Nominal pressure From ‐1 to 400 bar g
Density of the medium 350 kg/cm3
External material of the bypass chamber and flanges
Stainless steel, Hastelloy, Monel
Diameter of the float
50 x 0,5 (1), 50,8 x 0,8 (1,27)
Float material Stainless steel, titanium, PP, PVC, PVDF, ETFE
Scale Local indication
Float
Indication level
Metal float Plastic float
Measurement and Regulation
www.emkometer.com
Page 33 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
B2Standardoptionsfortopofchamber
Cap Flat Flat with plug, hex screw
Flat with plug, hex wrench
T1 T2 T3 T4 Flat with tabular end for
welding Flat vent flange Flat with needle valve Flat top with doubled
valves
T5 T6 T7 T8 Flat with ball valve G /
NPT Flat with flange with
plug Flat with flange with
valve Flange
with vent flange
T9 T10 T11 T12 Flange with ball valve G / NPT
Flange with tabular end for welding
Compact flange PN63 Compact flange PN250
T13 T14 T15 T16
Measurement and Regulation
www.emkometer.com
Page 34 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
B3Standardoptionsforbottomofchamber
Cap Flat Flat with plug, hex screw
Flat with tabular end for welding
B1 B2 B3 B4
Flat with drain flange
Flat with needle valve
Flat with doubled valves
Flat with ball valve G / NPT
B5 B6 B7 B8
Flat with flange with valve
Flange with cylindrical plug
Flange with conical plug Flange with drain flange
B9 B10 B11 B12
Flange with drain valve Flange with tabular end for welding
Flange with ball valve G / NPT
Flange with needle valve
B13 B14 B15 B16
Flange with doubled valves
Compact flange PN63 Compact flange PN250
B17 B18 T19
Measurement and Regulation
www.emkometer.com
Page 35 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
B4Orientationofprocessconnection
SS side ‐ side
The most commonly
used option of joining,
characterized by simply
mounting. Maximal
possible range readings
/ measurements is total
distance between
connecting pipes (L).
TS top ‐ side
Under this option, the
installation in upper
range measurement
appears "dead zone ",
which is equal to the
length of the upper
pocket (T). Measurement
possible to produce by
lower connecting nozzle.
Ventilation chamber may
provide horizontal fitting.
SD side ‐ down
Under this option, the
installation in lower
range measurement
appears "dead zone",
which is equal to the
length float chamber
(U). Measurements
possible produce to the
top the connecting pipe.
For drainage chamber
may provide horizontal
fitting.
TD top ‐ down
Under this option, the
installation in lower range
measurement appears
"dead zone", which is
equal to the length float
chamber (U). The the top
of the "dead zone" will be
equal to the upper pocket
(T). For ventilation /
drainage chamber may
provide horizontal
fittings.
Measurement and Regulation
www.emkometer.com
Page 36 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
B5Processconnectiontype
S1 Flat flange
S2 Collar flange
S3 Collar flange transition diameter
S4 Welded pipe
S5 Adaptor with male thread
S6 Socket with internal thread
There are also other types of process connections, such as flanges freely rotatable, quick couplings, Tri‐Clamp
connections and others.
Measurement and Regulation
www.emkometer.com
Page 37 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
B6Magneticrollerindicator
Indicator bar with metal rollers that meet the requirements for outdoor use, resistance to sunlight, resistance to temperature fluctuations ‐ dimensional stability and resistance to vibration. Metal rollers have lower pivot friction and therefore display shows lower hysteresis and a bigger margin range (up to 40 mm). For less demanding applications, it is possible to use plastic rollers.
IP Standard magnetic roller indicator with plastic rollers red / white up to +100°C With thermal shield PI up to +250°C (other code IP/PI)
IM Standard magnetic roller indicator with metal rollers red / white up to +300°C Increased protection degree IP68 With thermal shield PI up to +500°C (other code IM/PI)
IC Custom magnetic roller indicator with different colours of rollers e.g. black / yellow (plastic or metal rollers, thermal shield)
Other option
IS Indicator with traverse magnet
AC Acrylic console for cryogenic applications
Measurement and Regulation
www.emkometer.com
Page 38 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
B7Stainlesssteelscale
SM
Stainless steel scale
laser engraved in
millimeters
SC
Stainless steel scale
laser engraved in
centimeters
SP
Stainless steel scale
laser engraved in
percent
SX
Stainless steel scale
laser engraved on
agreement (for
example ‐250 ...
+250)
Measurement and Regulation
www.emkometer.com
Page 39 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
B8Connectingoption
DS Upper and lower damper spring
OV Shut‐off valves MB Mounting bracket
Measurement and Regulation
www.emkometer.com
Page 40 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
CAccessories
Measurement and Regulation
www.emkometer.com
Page 41 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
C1SPJLimitswitch
Standardspecification
Flameproof sensor allows monitoring of any level.
Its location is user adjustable. Sensor has marked switching point. Cable gland must be facing down. Sensor range is up to 45 mm from float chamber allowing placement outside the insulation.
Switch is also available in Ex d version.
II 2G Ex d IIC T4 ‐ T6 Gb II 1G Ex ia IIC T1 ‐ T6 Gb
Cable 4G x 0,75 ‐ external diameter 7,6 mm Standard cable length is 3 m and the cable cannot be shortened in Ex d variant.
Medium temperature From ‐40°C up to +450°C
Ambient temperature From ‐60°C up to +85°C
Accuracy, mm ±5 /±10 / ±15
Protection IP 68
Maximum current 3 A
Maximum voltage 400 V
Maximum power 100 W
Weight 0,4 kg
Explosion protection General‐Purpose 1/2G/A Ex ia IIC T6 ... T1 Ga/Gb
44
Measurement and Regulation
www.emkometer.com
Page 42 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
Manufacturertypenumber
Code
1 Basic type
SPJ SPJ ‐ Limit swich
2 Sensor placement (if ordered with level indicator)
3 Approval
NO NO
EXIA Ex ia
EXD Ex d
4 Parameter
LV LV ‐ to 175 V DC; 0,5 A; 10 W SPDT
HV HV ‐ to 400 V DC; 3 A; 100 W SPDT
NAM NAMUR
NAML NAMUR LED
SP1 Switching – max, to 250 V DC; 1 A; 60 W SPST
SP2 Switching – min, to 250 V DC; 1 A; 60 W SPST
Ordering example
Basic type Sensor
placement Approval Parameter
Code 1 2 3 4
SPJ / 500 / EXIA / LV
Measurement and Regulation
www.emkometer.com
Page 43 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
C2PotentiometriclevelsensorSP4
Standardspecification
Medium temperature From ‐40°C up to +450°C
Ambient temperature From ‐60°C up to +85°C
Accuracy, mm ±5 /±10 / ±15
Material probe Stainless steel
The diameter of the probe
14; 20,3 mm
Measurement range Up to 6000 mm
The output of sensor Potentiometer
Output built‐in converter
4‐20 mA 4‐20 mA HART® / SIL 2 PROFIBUS PA Foundation FIELDBUS
Availability display option
Optional
Explosion protection General‐Purpose 1/2G/A Ex ia IIC T6 ... T1 Ga/Gb
Measurement and Regulation
www.emkometer.com
Page 44 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
C3PotentiometriclevelsensorSP4inExdexecution
Standardspecification
Medium temperature From ‐40°C up to +250°C
Ambient temperature From ‐60°C up to +85°C
Accuracy, mm ±5 /±10 / ±15
Material probe Stainless steel
The diameter of the probe
14; 20,3 mm
Measurement range Up to 6000 mm
The output of sensor Potentiometer
Output built‐in converter
4‐20 mA 4‐20 mA HART® / SIL 2 PROFIBUS PA Foundation FIELDBUS
Availability display option Optional
Explosion protection General‐Purpose 1/2G/D Ex d IIC T6 … T1 Ga/Gb
Measurement and Regulation
www.emkometer.com
Page 45 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
Manufacturertypenumber
Code 1 Basic type
SP4 SP4 ‐ Electric output
2 Measurement range in mm
3 Resolution
5 5 mm
10 10 mm
15 15 mm
4 Approval
NO NO
EXIA Ex ia
EXD Ex d
5 Display
DL Local
DR Remote
6 Option
4‐20mA 4‐20 mA
HART 4‐20 mA HART
PB PROFIBUS
FF FOUNDATION FIELDBUS
Ordering example
Basic type Measurement
range Resolution Approval Display Option
Code 1 2 3 4 5 6
SP4 / 500 / 5 / NO / DL / HART
Measurement and Regulation
www.emkometer.com
Page 46 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
C4MagnetostrictivelevelsensorSP4/M
Standardspecification
Probe head
Protection class IP68
Material Stainless steel 303
Cable terminal M16 x 1.5 cable gland for cable diameter 5 to 10 mm ½” NPT threads for conduit cabling; M12 Connector
Ambient temperature ‐40°C to + 85°C
Probe tube
Material Stainless steel 316 Ti; Hastelloy® C4/C22
Accuracy
Filling level Up to ±0.3 mm or ±0.01 %
Resolution (HART®) 0.1 mm
Electrical connection
Connection 2‐wire
Voltage 8 to 30 V DC, Ex version 10 to 30 V DC
Signal Power output: 4 to 20 mA/HART®; Failure mode confirmed with NAMUR NE43 Serial Protocol to connect to LOGI‐X
HART® functions
Float position in mm, cm, m, inches or feet; positioning of second float; separation layer (difference between floats); sensor status information; remote configuration
Process conditions
Temperature Up to 450°C
Pressure Up to 200 bar
Options Vibration‐resistant design (to OIML D11) ATEX and IECEx approval Qualified for SIL 2 (IEC 61508)
Measurement and Regulation
www.emkometer.com
Page 47 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
Manufacturertypenumber
Code 1 Basic type
SP4/M SP4/M ‐ Magnetostrictive
2 Measurement range in mm
3 Resolution
02 0,2 mm
05 0,5 mm
4 Approval
NO NO
EXIA Ex ia
5 Display
DL Local
DR Remote
6 Option
4‐20mA 4‐20 mA
HART 4‐20 mA HART
Ordering example
Basic type Measurement
range Resolution Approval Display Option
Code 1 2 3 4 5 6
SP4/M / 1000 / 02 / NO / DR / HART
Measurement and Regulation
www.emkometer.com
Page 48 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
C5EMKOTDR‐60Radarlevelmeterswithguidedwave
Standardspecification
Supply voltage
EMKOTDR‐60N (NT) 18 … 36 V DC
EMKOTDR‐60Xi (XiT) 18 … 30 V DC
EMKOTDR‐60Xd (XdT) 18 … 36 V DC
Output type (var. "I") 4 … 20 mA (2‐wire),
HART
Output type RS‐485 (var. "M") protocol Modbus RTU
Basic error for range 2,0 ‐ 40 m ±2 mm
Resolution 1 mm
Ambient temperature ‐30°C … +70°C
Process temperature ‐40°C … +200°C
Process connection thread G1
Process pressure (for temparature +85°C)
for EMKOTDR‐60N‐10 (20, 30, 33) 0 … 100 bar
for EMKOTDR‐60N‐11 (12) 0 … 15 bar
for EMKOTDR‐60N‐32 0 … 5 bar
Protection class IP67
Device clarification
EMKOTDR‐60N performance for non‐explosive area
EMKOTDR‐60NT high temperature performance for non‐Ex / Ex areas
EMKOTDR‐60Xi (XiT) II 1/2 G Ex ia IIB T5 Ga/Gb
EMKOTDR‐60Xd (XdT) current output II 1 D Ex ta IIIC T85°…T300°C Da
output RS‐485 II 1 D Ex ta IIIC T100°…T300°C Da
Guided wave radar level measurement
The function principle of the impulse radar (microwave) level meter is TDR (Time Domain Reflectometry). The electronics transmits very short electrical pulses (0 .5 ns), which are linked to a one‐wire transmission line (measuring electrode). Measuring electrode can be created of rod or rope. The pulse propagates along the electrode in the form of electromagnetic wave toward the level surface, where it is partly reflected and the reflected component is returned to the receiving module of the electronics. The electronics measures the time of flight of electromagnetic wave and appropriately sets the value of the output signal.
The method is resistant against changes in the atmosphere (pressure, temperature, dust, steam) and to changes in medium parameters (change in dielectric constant, conductivity).
Suited to continuous level measurement of various liquids, mush and bulk‐solid materials.
Radar level meter with guided wave (TDR)
Universal use, direct mounting into containers, silos, vessels, reservoirs, etc.
Stainless steel rod or rope electrode
Measurement range up to 40 m
Xi, XiT versions for usage in explosive areas, or Xd, XdT versions for usage in flamable dusts areas
Linear measurement also in non‐conductive and in variously shaped tanks
Immediate view measured values on the display
Simple installation and settings
Current output (4 ... 20 mA) with HART® protocol or output RS–485 Modbus
Measurement and Regulation
www.emkometer.com
Page 49 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
C6EMKOCAP‐25Capacitivelevelmeters
Standardspecification
Supply voltage current output (var. „I“) 9 ... 34 V DC
voltage output (var. „U“) 12 ... 34 V DC
Output type (var. “I”) 4 ... 20 mA (2‐wire)
Output type (var. “U”) 0 ... 10 V (3‐wire)
Accuracy (from full measured range)
1%
Ambient temperature ‐40°C ... +85°C
Temperature range on electrode
‐40°C ... +200°C
Process connection thread M27x2 ; M30x1,5 ; G ¾“;
NPT ¾; TriClamp
Protection class IP67
For continuous level measurement of liquid and bulk‐solid materials.
Direct mounting into containers, vessels, basins, reservoirs, etc.
Possibility of linear measurements even in non‐conductive and differently shaped containers
Simple sensitivity setting by means of magnetic pen
LED state and function indication
Wide choice of electric connection via connectors, cable glands, or protective conductor
Material of housing and rod electrodes from stainless steel
EMKOCAP‐26Capacitivelevelmeters
Standardspecification
For continuous level measurement of liquid and bulk‐solid
Direct mounting into containers, silos, vessels, basins, reservoirs, etc.
Possibility of linear measurements even in non‐conductive and differently shaped containers
Selectable measurement ranges
Easy and quick connecting by connector
Continuous adjustment of initial capacity
Xi version for usage in explosive areas
Material of housing and rod electrodes from stainless steel
Supply voltage current output (var. „I“) 9 ... 36 V DC
voltage output (var. „U“) 11 ... 36 V DC
Output type (var. “I”) 4 ... 20 mA (2‐wire)
Output type (var. “U”) 0 ... 10 V (3‐wire)
Accuracy (from full measured range) 1%
Ambient temperature ‐40°C ... +85°C
Temperature on electrode ‐40°C ... +200°C
Process connection thread M36×2; G 1"; TriClamp
Protection class IP65 / IP67
Measurement and Regulation
www.emkometer.com
Page 50 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
C7Thermalinsulation
Standardspecifications
Medium temperature Up to +130°C for Armaflex foam Up to +500°C for basalt wool Up to +1100°C for Sibrex ceramic ins.
The material of the outer shell insulation
Stainless steel / Armaflex foam
Diameter of the external chamber
No restriction
Operating range pointer
No restriction
Vent Removable box for ventilation / plug
Drain Removable box for drainage
Range of regulated temperature
From ‐196 to +400°C
Scale On two scales can be applied different
units
Order code AFI, SAI, SCI, PI
AFI – Armaflex foam insulation SAI – stainless steel angular insulation
PI – preparation for insulation
SCI – stainless steel circular
insulation full cover
Measurement and Regulation
www.emkometer.com
Page 51 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
C8ElectricalheatingwiththermalinsulationOE
Standardspecifications
Self‐regulating heating cable
supporting electrical heating
freeze protection, temperature maintenance (tempering)
safe and reliable, without overheating or burn,
simple design, no complex calculations
flexible, extendable on site
in potentially explosive atmospheres (Ex)
QTRV Outputs from 38 to 64 W/m (at 10°C) Max. temperature: 110°C (always on) without overheating or burnout
KTV Outputs from 16 to 65 W/m (at 10°C)
Max. temperature: 150°C (always on)
suitable for steam flushing
VPL Outputs from 15 to 61 W/m (at 10°C)
Max. temperature: 230°C (always on)
suitable for steam flushing
Medium temperature Up to +130°C for the foam rubber Up to +500°C for basalt wool
The material of the outer shell insulation
Stainless steel
Diameter of the external chamber
No restriction
Operating range pointer
No restriction
Vent Removable box for ventilation / plug
Drain Removable box for drainage
Range of regulated temperature
From +5 to +250°C
Scale On two scales can be applied different
units
Insulation code AFI, SCI, SAI, PI
Order code OE
OE / SCI
Measurement and Regulation
www.emkometer.com
Page 52 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
C9Heatingjacket(steam,water)withinsulation
Standardspecifications
Medium temperature Up to +130°C for the foam rubber Up to +500°C for basalt wool
The material of the outer shell insulation
Stainless steel
Diameter of the external chamber
No restriction
Operating range pointer
No restriction
Vent Removable box for ventilation / plug
Drain Removable box for drainage
Range of regulated temperature
Depending on the type of coolant
Scale On two scales can be applied different
units
Insulation code AFI, SCI, SAI, PI
Order code OP, OPTA, OPTB
OP
OPTA / SCI OPTB / SCI
Measurement and Regulation
www.emkometer.com
Page 53 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
C10Signaltransducersoflevelortemperature
Ambient temperature From ‐40°C tо +85°C
Input range 0…100 kΩ
Accuracy ≤ ±0,1% of the measurement range
Output signal 4…20 mА
Display no
Explosion protection General‐Purpose 0 Ex ia IIC T6…T1 Ga
Measurement and Regulation
www.emkometer.com
Page 54 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
L21ManufacturertypenumberCode 1 Basic type
L21 Magnetic Level Indicator L21/3 Magnetic Level Indicator top‐mounted with a float on a string L21/4 Magnetic Level Indicator top‐mounted with a float on a rod L21/5 Buoyancy Level Indicator L21/C Magnetic Level Indicator for containers 2 Distance centre‐to‐centre in mm 3 Orientation of process connection
SS Side‐side TS Top‐side SD Side‐down TD Top‐down 4 Process connection
S1 Flat flange DN.. PN.. S4 Welded pipe Do (outer diameter) x S (wall thickness) S2 Collar flange DN.. PN.. S5 Adaptor with male thread G, M, NPT dimension S3 Collar flange transition diameter DN.. PN.. S6 Socket with internal thread 5 Facing types
A, B, C, D, E, F, G, H (EN‐1092‐1) RF, SF, FF, RTJ, SG, LG, SM, SF (ASME B16.5) 1, 2, 3, 4, 5, 6, 7, 8, 9 (GOST 12815‐80) A, B, C, D, E, F, J, K, L, M (GOST P 54432‐2011) 6 Top of chamber / vent
T1 Cap T7 Flat with needle valve T13 Flange with ball valve G / NPT
T2 Flat T8 Flat with doubled valves T14 Flange with with tabular end for welding
T3 Flat with plug, hex screw T9 Flat with ball valve G / NPT T15 Compact flange PN63
T4 Flat with plug, hex wrench T10 Flat with flange with plug T16 Compact flange PN250
T5 Flat with tabular end for welding T11 Flat with flange with valve T6 Flat vent flange T12 Flange with vent flange 7 Bottom of chamber / drain
B1 Cap B8 Flat with ball valve G / NPT B15 Flange with ball valve G / NPT
B2 Flat B9 Flat with flange with valve B16 Flange with needle valve B3 Flat with plug, hex screw B10 Flange with cylindrical plug B17 Flange with doubled valves B4 Flat with tabular end for welding B11 Flange with conical plug B18 Compact flange PN63
B5 Flat with drain flange B12 Flange with drain flange B19 Compact flange PN250
B6 Flat with needle valve B13 Flange with drain valve B7 Flat with doubled valves B14 Flange with tabular end for weld. 8 Material of chamber
N Stainless steel PE Polyethylene PP Polypropylene ETFE Ethylene tetrafluoroethylene PVDF Polyvinylidene fluoride Other material 9 Approval
NO Normal environment
EX Explosive environment 10 Magnetic roller indicator
IP Standard magnetic roller indicator with plastic rollers
IM Standard magnetic roller indicator with metal rollers
IC Custom magnetic roller indicator
IS Indicator with traverse magnet AC Acrylic console for cryogenic applications 11 Scale
SM SST laser engraved in millimeters SC SST laser engraved in centimeters SP SST laser engraved in percent SX SST laser engraved on agreement 12 Heating
OE Electrical heating OP Heating jacket (water, steam) OPTA Heating jacket (water, steam), U shaped tube OPTB Heating jacket (water, steam), simple tube 13 Insulation
AFI Armaflex foam SAI Stainless steel angular SCI Stainless steel circular PI Preparation for insulation (thermal shield) 14 Option
DS Upper and lower damper spring OV Shut‐off valves
Measurement and Regulation
www.emkometer.com
Page 55 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
MB Mounting bracket ZO Special design ‐ pollutant, sediment and crystallizing liquids
Ordering example
Basic type
Distance centre‐to‐
centre
Orientation of process connection
Process connection
Facing
Top of chamber / vent
Bottom of
chamber / drain
Material of
chamber
Approval
Magnetic roller
indicator Scale Heating Insulation Option
Code 1 2 3 4 5 6 7 8 9 10 11 12 13 14
L21 / 2500 / SS / S1DN25 PN16
/ B1 / T2 / B2 / N / NO / IM / SM / OE / SCI / MB
Ordering
When ordering please specify:
Type of medium, concentration in %, the content of mechanical and ferromagnetic impurities
Density and viscosity
Temperature and pressure (operating and maximal)
Measurement range
Units
Requirements for the electrical outputs
Installation
Before you install the device, check that the measuring body doesn’t contain any impurities
Careful when inserting the float into its proper position, the upper part has two indentations at a
distance of 6 mm from each other
Sealing must be centered in the flanges and threads
Fittings can be tighten by torque specified for the operating pressure in the tanks
Each unit is pressure tested 1.5 times of the operating pressure, which is specified in the order, the float
is only tested 1.3 times of the pressure
Check the operating data on level meter label if that correspond to the measured liquid
Before commissioning, make sure the drain and air plugs, drain and air valves are closed
Open the shut‐off valve at the meter connecting flanges, first upper valve
Now it’s ready for measurement
Avoid pressure surges and abrupt changes in level ‐ risk of float damage
During handling with the level indicator it’s necessary to avoid abrupt changes in position so
that the float chamber due to the acceleration of gravity moved as slowly as possible in order to prevent
impact damage.
It’s recommended to separate level meter from the vessel by valves
Maintenance
During normal operation device does not require special maintenance. Operation focuses only on checking for
leaks, or contaminated liquids in measuring the periodic draining or flushing the measuring tube, or cleaning
float. During this activity follow appropriate safety, fire and environmental measures.
Electrical connection may only be performed by an authorized person.
Measurement and Regulation
www.emkometer.com
Page 56 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
Appendix1
EN‐1092‐1facingtypes
Measurement and Regulation
www.emkometer.com
Page 57 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
Appendix2
ASMEB16.5facingtypes
Raised face Lap joint
Large male and female Small male and female
Large tongue and groove Small tongue and groove
Flat face Flange with welding pipe
Ring joint Small male and female
Measurement and Regulation
www.emkometer.com
Page 58 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
Appendix3
GOST12815‐80,GOSTP54432‐2011facingtypes
Measurement and Regulation
www.emkometer.com
Page 59 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
Appendix4
Table pressure ‐ temperature ANSI
ASME / ANSI B16.5 – 1988
Maximum pressure in MPa
Temperature in °C 150 lbs 300 lbs 600 lbs 900 lbs 1,500 lbs 2,500 lbs
37 1,89 4,96 9,92 14,89 24,82 41,36
93 1,65 4,27 8,54 12,82 21,33 35,57
148 1,48 3,86 7,72 11,58 19,27 32,12
204 1,34 3,55 7,10 10,61 17,71 29,50
260 1,17 3,30 6,58 9,89 16,47 27,44
315 0,96 3,10 6,23 9,34 15,54 25,92
343 0,86 3,06 6,13 9,17 15,30 25,51
371 0,75 2,96 5,96 8,92 14,89 24,82
398 0,65 2,93 5,82 8,75 14,54 24,26
0,00
5,00
10,00
15,00
20,00
25,00
30,00
35,00
40,00
45,00
37 93 148 204 260 315 343 371 398
150 lbs
300 lbs
600 lbs
900 lbs
1500 lbs
2500 lbs
Teplota ve °C
Tlak v MPaPressure in MPa
Temperature in °C
Measurement and Regulation
www.emkometer.com
Page 60 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
Appendix5
Commonly used flanges
Dimensions in mm
CSN EN 1092
PN 40 D0 D1 D2 D3 D4 a f h V
DN 25 34,5 115 85 68 33,7 18 2 6 40
DN 40 49,5 150 110 88 48,3 18 2 7 45
DN 50 61,5 165 125 102 60,3 20 2 8 48
ANSI B 16.5
150 lbs D0 D1 D2 D3 D4 a f h V
1" 26,7 108 79,2 50,8 33,5 14,2 1,6 ‐ 55,6
1 1/2" 40,9 127 98,6 73,2 48,3 17,5 1,6 ‐ 62
2" 52,6 152,4 120,7 91,9 60,5 19,1 1,6 ‐ 63,5
Measurement and Regulation
www.emkometer.com
Page 61 of 61
L21 Magnetic Level Indicator | Emkometer s.r.o., Na Žižkově 1245, Ledeč n/S., 58401, CZ
tel/fax: 569 721 622 | tel: 569 720 539, 569 721 549 | [email protected]
Appendix6
Example design of the terminal box:
Just for illustration, actual connection may vary depending on your configuration. Connection schematics is
supplied with each device.
Example of electrical connection:
Terminal box 2x4 terminals from each side
for conductor 1,5mm2
Cable gland for cable Ø 8mm
Gland with plug
Cable gland M20 x 1,5 for