_ku_ni_vodovod_1383807536218
DESCRIPTION
sasasasaTRANSCRIPT
-
KUNI VODOVOD
IV predavanje
KUNI VODOVOD
OBUHVATA SVE ELEMENTE VODOVODNE INSTALACIJE, OD PRIKLJUKA NA ULINOJ MREU DO POSLEDNJEG POTROAA U ZGRADI
SASTOJI SE OD :1.VODOVODA MOKRIH VOROVA2.VODOVODA VERTIKALNOG RAZVODA3. HORIZONTALNOG RAZVODA SA PRIKLJUKOM NA
UL.MREU
-
OZNAKE ZA VODOVOD U PROJEKTU
VODOVOD MOKROG VORA POINJE OD VERTIKALE HORIZONTALNIM ODVAJANJEM :
/na tri mogua naina/
1. NA 30cm IZNAD PODA
2. U VISINI TOEEG MESTA
3. U PODU
30 cm
-
...O EMU TREBA VODITI RAUNA KADA SE PROJEKTUJE-REAVA MOKRI VOR ?...
RAZVOD VODOVODNIH CEVI U MOKROM VORU IMA PAD OD 1% PREMA VERTIKALI
ZA VODOVE PO SPRATU KORISTITI CEVI PROFILA 15MM ili COLA
ISPRED SVAKOG TOEEG MESTA POSTAVITI ODGOVARAJUI VENTIL
-
...KAKO SE PRIKAZUJE RAZVOD VODOVA NA CRTEU?... IZOMETRIJSKIM CRTEOM
1. SVI HORIZONTALNI VODOVI U OSNOVI OSTAJU HORIZONTALNI NA CRTEU.SVE VERTIKALE I VERTIKALNI VODOVI SE PRIKAZUJU VERTIKALNO.2. LINIJE KOJE SU UPRAVNE NA HORIZONTALU U OSNOVI SE CRTAJU POD UGLOM OD 30 ili 45.3. DUINE VODOVA SE OBELEAVAJU U REALNIM MERNIM JEDINICAMA / cm,m /
...KAKO SE IZRAAVA KOLIINA UTRONE VODE NA TOEEM MESTU?...
SVAKO TOEE MESTO TROI ODREENU KOLIINU VODE, TO SE IZRAAVA KROZ MERUJEDINICA OPTEREENJA JO predstavlja koliinu vode koja protie kroz cev od 15mm pod pritiskom od 5 bara
1JO = 0.25 l/sec OD NJE ZAVISI I DIMENZIONISANJE CEVI KOJE SE
RADI PREMA BRIX-OVIM TABLICAMA
-
VERTIKALNI RAZVOD
ON SE SATOJI OD:
VERTIKALA i SPRATNIH OGRANAKA
VODOVODNE VERTIKALE:
PO POLOAJU PRATE KANALIZACIONE VERTIKALE
NJENA DUINA JE OD HORIZONTALNOG RAZVODA DO NAJVIEG IZLIVNOG MESTA /NIM-na slici./ U ZGRADI
U DNU SVAKE VERTIKALE TREBA POSTAVITI PROPUSNO ISPUSNE VENTILE
/PRANJENJE MREE I MOGUNOST INTERVENCIJE/
ONA NEMA ISTI PROFIL PO CELOJ VISINI, VE SE ON DIMENZIONIE PO BRIKSOVIM TABLICAMA
MOGUI POLOAJ NAINI CRTANJA VERTIKALA
OBELEAVA SE U PROJEKTIMA KAO, W
vodovodna vertikala
kanalizaciona vertikala
-
HORIZONTALNI RAZVOD
HORIZONTALNI RAZVOD POINJE OD ULINOG PRIKLJUKA /SPOJA/ IDE UPRAVNO NA OBJEKAT
VODOMER SE POSTAVLJA NA CEV KOJA IDE OD SPOJA NA 1-1,5 M OD REGULACIONE LINIJE PORED OBJEKTA ILI U SAMOM OBJEKTU
KADA PROBIJE FASADNI ZID, CEV SE DIE UPRAVNO DO 30 CM ISPOD PLAFONA PODRUMA GDE SE RAZVODI DO MESTA VODOV.VERTIKALA / W/
AKO OBJEKAT NEMA PODRUM CEVI SE VODE ISPOD PODA PRIZEMLJA, ALI ONDA SE CEVI DODATNO OBLAU I ZATIUJU OD KOROZIJE
PRIKAZ RAZVODA VODE U OBJEKTU
-
VODOMER
F-ja : MERI POTRONJU VODE POSTAVLJA SE U DVORITI U VODOMERNOM OKNU ili
U OBJEKTU-VODOMERSKO SANDUE. MESTO MU JE NA ZIDU, U NII ILI NA KONZOLNIM NOSAIMA NA 1-1,2 M OD PODA I MORA BITI ZAKLJUANO
SASTOJI SE IZ PROPUSNOG VENTILA /PREMA ULICI/ I PROPUSNO-ISPUSNOG VENTILA PREMA ZGRADI. PREKO DRUGOG VETILA MOE SE ISPRAZNITI INSTALACIJA SA VODOM ILI SNIAVATI PRITISAK U MREI I NJIM MOE RUKOVATI KORISNIK ILI VLASNIK OBJEKTA
VODOMER SE MORA POSTAVITI HORIZONTLNO U OKNU KROZ VODOMERNO OKNO SE NE SMEJU VODITI DRUGE INSTALACIJE NA DNU OKNA TREBA STAVITI SLIVNIK ZBOG VEZE SA KANALIZACIJOM DIMENZIJE OKNA I SANDUETA ODREUJU SE PRAVILNIKOM GRADSKOG
VODOVODA
VODOMERNA OKNA VAN ZGRADE
-
VODOMERNA OKNA U ZGRADI
TOPLA VODA
snabdevanje objekta toplom vodom:
LOKALNI UREAJI BOJLERI/akumulacioni, protoni//elektrini, plinski, solarni/
CENTRALNI UREAJI- KOTLARNICE
DALJINSKO ZAGREVANJE VODE i razvod do potroaa
-
PRIKAZ TOPLE I HLADNE VODE NA PROJEKTUVODOVODA
...SNABDEVANJE VODOM U VISOKIM ZGRADAMA...
1. DODATHNI REZERVOARI
MESTO REZERVOARA JE NA NAJVILJOJ ETAI ZGRADE
JEDAN DEO ZGRADE SE SNABDEVA DIREKTNO IZ ULINOG PRIKLJUKA, A DRUGI VILJI DEO VODOM KOJA TEE SLOBODNIM PADOM IZ REZERVOARA
VODA IZ ULINOG PRIKLJUKA SE VODENOM PUMPOM, PREKO VENTILA SA PLOVKOM, DOPREMA DO REZERVOARA
2. HIDROFOR
UREAJI ZA POVEANJE PRITISKA POMOU KOMPRIMOVANOG VAZDUHA U KUNOJ MREI
MESTO MU JE UZ OBJEKTE VELIKE SPRATNOSTI, GDE SE NE MOE OBEZBEDITI DOVOLJAN PRITISAK U MREI ZBOG VELIKE GEODETSKE RAZLIKE U VISINI NAJNIE I NAJVILJE TAKE TOEEG MESTA U OBJEKTU
OBEZBEUJE NORMALAN PRITISAK GRADSKE VODOVODNE MREE
-
HIDROFOR OMOGUAVA BOLJI PRITISAK U MREI POMOU KOMPRINOVANOG VAZDUHA
...SNABDEVANJE VODOM VISOKIH ZGRADA...a/DODATNI REZEROVAR b/HIDROFOR
-
...BITNI PARAMETRI ZA PRORAUN VODOVODA I DIMENZIONISANJE CEVI...
NA DIMENZIJE CEVI UTIE :1.KOLIINA VODE NA MESTU IZLIVA2.PRITISAK VODE U MREI3.BRZINA VODE U CEVIMA
U GRADSKOJ MREI VODA TEE POD PRITISKOM OD 3-6 BARA
....KAKO SE RADI HIDRAULIKI PRORAUN VODOVODA....
ULAZNI PODACI SE DOBIJAJU OD KOMUNALNIH SLUBI, A TO JE MESTO PRIKLJUKA NA UL. MREU I RASPOLOIVI PRITISAK U MREI
U OSNOVAMA, U MOKRIM CVOROVIMA, UCRTATI HORIZONTALNI RAZVOD TOPLE I HLADNE VODE SA VERTIKALAMA, POTREBNIM DUINAMA I JEDINICAMA OPTEREENJA
NA OSNOVU CRTEA RADI SE IZOMETRIJA I RAZVODI VODE U CELOM OBJEKTUIZOMETRIJA SADRI SVE JEDINICE OPTEREENJA SA DUINAMA,TJ. TRASAMA CEVI I VERTIKALA
DIMENZIONISANJE CEVI SE RADI PO BRIX-OVIM TABLICAMA
GUBICI U MREI:
1.TRENJE PRI PROTOKU KROZ CEVI 2.GUBITAK NA SPOJU I VODOMERU /5M VODENOG STUBA/3.GUBITAK NA GEODETSKU VISINU ZGRADE/RAZLIKA U KOTI IZMEU NAJVIE TAKE I NAJNIE U MREI, A TO JE KOTA SPOJA/
SLOBODAN NADPRITISAK MREE se dobija kada se od raspoloivog pritiska mree oduzme zbir svi gubitaka na mrei
ISPITIVANJE INSTALACIJE VODOVODA
PO ZAVRETKU UGRADNJE VODOV.INSTALACIJA CELA MREA SE ISPITUJE NA VODONEPROPUSTLJIVOST I ISPRAVNOST, A TEK POTOM SE ROVOVI ZATRPAVAJU
IZVODI SE POSTAVLANJEM VAZDUNE PUMPE NA PROPUSNI VENTIL. CELA MREA SE PUMPA VAZDUHOM ILI VODOM I IZLAE SE ZA 50-100% VEEM PRITISKU OD RADNOG U TRAJANJU OD 3-6 SATI.
O CELOM POSTUPKU SE PRAVI ZAPISNIK U PRISUSTVU NADZORNOG ORGANA,IZVOAA I LJUDI IZ VODOVODA
-
SADRAJ ELABORATA VODOVODA I KANALIZACIJE
RADI SE NA OSNOVU ARHITEKTONSKOG PROJEKTA
PRVO SE RADI PROJEKAT KANALIZACIJE, PA ZATIM VODOVODA
ELABORAT SADI:1. PROJEKTNI ZADATAK2. TEH.OPIS3. USLOVE KOMUNALNOG
VODOVODA I KANALIZACIJE4. SAGLASNOST KOMUNALNOG
VODOVODA I KANALIZACIJE5. SITUACIJU R 1:100, R 1:2006. OSNOVE KANALIZACIONE I
VODOVODNE MREE R1:50, R 1:100
7. PRESEKE KANALIZACIONE I VODOVODNE MREE R1:50, R 1:100
8. IZOMETRIJSKA EMA VODOVODA
9. HIDRAULINI PRORAUN VODOVODNE MREE
10.PREDMER I PREDRAUNRADOVA
POLOAJ VERTIKALA U OBJEKTU
Kanalizacione vertikale van zidova u instalacim blokovima, ne sme setemovati AB konst.zid.Fekalne vert PVC 110,160,200Fek.vert kerm.100,150, 200Kuhinja vert PVC 75, 70 keramika
-
OZNAKE I SIMOBILI SANITARNOG PRIBORA U PROJEKTIMA
VEZA SANITARNOG PRIBORA SA KANALIZACIJOM
-
KUHINJE-VEZA SUDOPERE SA KANALIZACIJOM
REAVANJE KANALIZACIONOG RAZVODA KLOZETA