kr-7016g manual 20130515

Upload: voinea-andrei

Post on 03-Jun-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/12/2019 KR-7016G Manual 20130515

    1/31

    GSM&PSTNDual-Network

    Burglar Alarm System

    (KR-7016)

    User Guider

  • 8/12/2019 KR-7016G Manual 20130515

    2/31

    Table of the content

    1 Summarize1.1 Introduce ----------------------------------------------------------------- 11.2 System Features ---------------------------------------------------------------- 1

    2 Alarm System Operation

    2.1 Arm ---------------------------------------------------------------- 12.2 Stay Arm -------------------------------------------------------------- 12.3 Disarm ----------------------------------------------------------- 22.4 Emergency ------------------------------------------------------------ 22.5 Alarm system Setup ------------------------------------------------------------- 22.6 SIM Card Installation ------------------------------------------------------- 42.7 Summary of Indicators ------------------------------------------------------- 42.8 After receiving the Panel Alert: ------------------------------------------------------- 52.9 Remote Dialing In Operation ------------------------------------------------------- 5

    3 system settings3.1 Alarm Panel Initial Setup -----------------------------------------------------------6

    3.2 Pre-record Voice Message ----------------------------------------------------------6

    3.3 Add Remote Control --------------------------------------------------------------63.4 Delete the remote control -------------------------------------------------------------6

    3.5 Add detector --------------------------------------------------------------------6

    3.6 Delete detector --------------------------------------------------------------------6

    3.7 Commands for Configuration --------------------------------------------------------- 73.7.1 Set up voice alarm phone number ---------------------------------------------------- 73.7.2 Delete voice alarm phone number ---------------------------------------------------- 7

    3.7.3 Set phone number to receive SMS message ----------------------------------------------------------------73.7.4 Delete SMS phone number --------------------------------- ---------------------------------------------8

    3.7.5 Password modification ----------------------------------------------------------------------------------------8

    3.7.6 Set delay for system arm -----------------------------------------------------------------------------------------8

    3.7.7 Set the time of delay for alarming ------------------------------------------------------------------------------8

    3.7.8 Set length of Siren sound -------------------------------------------------------------------------------------8

    3.7.9 Set the scope of control of alarm panel and remote control ---------------------------------------------------9

    3.7.10 Set audible confirmation for remote control operation ---------------------------------------------------9

    3.7.11 Set date and time settings ----------------------------------------------------------------------------------------9

    3.7.12 Scheduled arm and disarm time setting ----------------------------------------------------------------------9

    3.7.13 Scheduled arm and disarm zones settings ------------------------------------------------------------------10

    3.7.14 Set the type of defense zone -----------------------------------------------------------------------------10

    3.7.15 Set mode of wired alarm zone ------------------------------------ --------------------------------------------10

    3.7.16 Set Remote Operation on or off ------------------------------------------------------------------------11

    3.7.17 Assign specific phone number to certain zone ---------------------------------------------------------------11

    3.7.18 Set tamper device ON/OFF ---------------------------------------------------------------------------------------11

    3.7.19 set remote and keyboard for stay defense zones to control arming/disarming --------------------------11

    3.7.20 System voice volume adjustment ----------------------------------------------------------------11

    3.7.21 Power save mode ON /OFF -------------------------------------------------------------------------11

    3.7.22 Built-in Siren volume adjustment ---------------------------------------------------------------113.7.23 Set audible confirmation from panel to on or off ---------------------------------------------------11

    3.7.24 Enable or disable the SMS Messaging ----------------------------------------------------------------11

    3.7.25 Enable or disable of the anti-tampering of telephone cord ------------------------------------------12

  • 8/12/2019 KR-7016G Manual 20130515

    3/31

    3.7.26 External siren volume adjustment ------------------------------------------------------------12

    3.7.27 Forced disarm from panel keyboard ------------- --------------------------------------------12

    3.7.28 Turn on or off Interference Alert --------------------------------------------------------------------12

    3.7.29 Keyboard password protection feature -------------------------------------------------------------12

    3.7.30 Set number of ring tones before picking up --------------------------------------------------------------12

    3.7.31 Set integrated alarming -----------------------------------------------------------------------------12

    3.7.32 Restore factory setting ---------------------------------------------------------------------------133.7.33 Total System Reset -------------------------------------------------------------------------13

    3.8 Commands for Alarm center ------------------------------------------------------------------------------------13

    3.8.1 Set up alarm center number --------------------------------------------------------------------------------13

    3.8.2 Delete alarm center number ----------------------------------------------------------------------------------13

    3.8.3 Zone setting -------------------------------------------------------------------------------------------------13

    3.8.4 Set the mode of uploading arm/disarm message --------------------------------------------------------------14

    3.8.5 Set CID center account -------------------------------------------------------------------------------14

    3.8.6 Scheduled self-checking setting -----------------------------------------------------------------------------------14

    3.9 Commands of System Enquiries ------------------------------------------------------------------------14

    3.10 SMS Commands -------------------------------------------------------------------------------------------------17

    3.10.1 Remote SMS disarm -----------------------------------------------------------------------------------17

    3.10.2 Remote SMS NORMAL arm -------------------------------------------------------------------------17

    3.10.3 Remote SMS STAY arm ------------------------------------------------------------------------------------17

    3.10.4 Remote SMS turn on relay -----------------------------------------------------------------------------------17

    3.10.5 Remote SMS turn off relay ------------------------------------------------------------------------------------17

    3.10.6 query arming/disarming, power and relay status-------------------------------------------------------------------17

    3.10.7 Query the alarm panel general settings ---------------------------------------------------------------------17

    3.10.8 Query anti-tampering of phone cord and number of rings before pick-up --------------------------------18

    3.10.9 Query system setting ---------------------------------------------------------------------------------183.10.10 Query voice alarm phone number ---------------------------------------------------------------------18

    3.10.11 Query phone number for SMS message ------------------------------------------------------------------18

    3.10.12 Query assignment of remote control to defense zone -----------------------------------------------------18

    3.10.13 Querying alarm panel system time --------------------------------------------------------------------------18

    3.10.14 Check the status of scheduled arm/disarm ---------------------------------------------------------------------18

    3.10.15 Check the type and siren setting of wireless defense zone -----------------------------------------------------18

    3.10.16 Check the settings of wired defense areas ------------------------------------------------------------------19

    3.10.17 Query phone number assignment to zone -----------------------------------------------------------------19

    3.10.18 Customize the SMS message for certain zone ----------------------------------------------------------------19

    3.10.19 Query the customized SMS message content -----------------------------------------------------------------19

    3.11 Calling Function ------------------------------------------------------19

    3.12 Definitions of Zones ----------------------------------------------------------19

    3.13 Other System Default -------------------------------------------------------20

    3.14 Fitting parameters ----------------------------------------------------------------------------------20

    4 Guideline of Installation Sensors and Troubleshooting4.1 Guideline for Installing Door or Window Sensor ---------------------------------------------------20

    4.2 Guideline for Installing PIR Motion Sensor --------------------------------------------------------------------21

    4.3 Troubleshooting --------------------------------------------------------------------------------------21

  • 8/12/2019 KR-7016G Manual 20130515

    4/31

    1.Summarize

    1.1 Introduce

    This LCD English white back-light large-screen GSM &PSTN wireless burglar alarm system is used leadingmicroprocessor technology,high sensitivity superheterodyne receiver module, advanced GSM digital signalprocessing technology, combination with the traditional telecommunication network technology. It have many

    function as Digital voice, short message in English, learning to wireless code, remote control wireless homeappliance, message recognition, etc.

    It connect with wireless infrared detector, door sensor, smoke detectors, gas detectors, emergency buttonand other accessories. When the detector is trigger,the alarm system will notify the user by call and SMSmessage, and at the same time upload alarm information to alarm center.It is a choice of stability, reliability,security, and user friendliness security product. Features are very practical, cost-effective, completedconfiguration and ease of use. It has been widely used in homes, factories, schools, shops, conveniencestores, financial and banking workplace, community center and residential area to provide protection tovaluable assets.

    1.2 System Features

    Large LCD English white back-light display, voice prompt, the voice volume is adjustable, full of referenceinformation.

    Support dual-network of both PSTN landline and GSM mobile network, provide redundancy for extrastability

    The host can be used as an normal mobile phones

    Built-in siren, 8 level volume is adjustable, can be connect with an external siren

    Compatible with the international alarm networking protocol CONTACT ID.

    Allow up to 16 wireless defense zones and 2 wired zones,each wireless zones can be defined as one of the8 zone types,wired zones can be choose the NC or NO alarm

    Four sets of scheduled arm/disarmed function, each timed arm/disarm you can select the period of timeand different defense zone

    Phone or SMS remote Settings Alarm system Host function is available

    Telephone (phone) long-distance control for arming, disarming, monitoring and speaking.

    6 group voice alarm phone number for alert calling, 6 group number for SMS messaging and two groupCID center number

    Support ISD automatic voice mailbox for playback message upon alert. Maximum length of voice messageis 10 seconds.

    1 group of NO relay signal output,closed when alarm,remote control electrical appliances in 1000w

    Wireless intelligent study coding, compatible with PT2262 normal encoding and a 1527 encoding

    Maximum support 150 remote control and 150 detectors.

    Each remote control can control arm/disarm the special zones

    Unique black box features, you can display most recent 72 disarmed records and 102 recent alarmrecording.

    Built-in Ni-MH rechargeable battery and automatically switchable upon power failure, and notification will be

    sent via SMS.Panel integrated with either dual-band, triple-band, quad-band GSM/GPRS industrial graded module,stable and reliable.

  • 8/12/2019 KR-7016G Manual 20130515

    5/31

    2.Alarm System Operation

    2.1 Arm

    The system is at a fully ready status where all detectors are activated in a working state, when the someevents ( burglar, fire, gas leak, etc ) happened and detected, alarm system alarm right away. In ARM status,

    the panel lcd screen is on,

    To activate using remote control: press key once.

    To activate using keyboard: on panel keyboard keys once.

    2.2 Stay Alarm

    This is for partial arming of the alarm system when there are people at home, only some of the selectedsensors are activated and could be triggered by events.

    In a STAY ARM status,the panel lcd screen is on,

    To activate using remote control: press S key once.

    To activate using keyboard: on panel keyboard keys once.

    2.3 Disarm

    All sensors are deactivated and will not be respond to any events.(expect the detector in Emergency zones

    and the Panic button in the remote control In a DISARM status, the panel is on.

    To activate using remote control: press key once.

    To activate using keyboard: on panel keyboard keys once.

    2.4 Emergency

    When an emergency occurs, press button on the remote or the button on panel to activate

    alarm.

    Remark:

    If password on keyboard is enabled, you need to enter password before other operations, the initialpassword is 1234.

  • 8/12/2019 KR-7016G Manual 20130515

    6/31

    2.5 Alarm System Setup

    Alarm panel should be installed at a central location with best transmission to all the wireless sensors andaccessories. Keep the panel well away from large metal objects or household appliances with high-frequencyinterference, and avoid barriers such as concrete walls with metal frame inside and fire doors.

  • 8/12/2019 KR-7016G Manual 20130515

    7/31

    2.6 SIM card installation

    SIM card installation is simple. Firstly remove the cover of SIM card slot at the back of the alarm panel andthen place the card according to direction indicated. Make sure the cover of SIM card slot is fixed suitably.

    2.7 Summary of Indicators

    Function Indications Description

    Built-in speaker short "beep" once KeyTip

    short "beep" twice Exit configuration or learnt succeed

    short "beep" three times Error indication

    Voice prompt The function and status of prompt voice

    wuwuwu alarm

    Power icon display on LCD

    Panel power is normal

    icon display on LCD Alarm panel external power disconnect, usingbattery

    LCD without anyinformation

    Alarm panel without power supply

    ARM icon display on LCD

    Alarm panel at ARM mode

    icon display on LCD Alarm panel at STAY ARM mode

    icon is flashing Alarm panel at DelayARM mode

    icon display on LCD Alarm panel at Disarm mode

    ALARM 1-16 display on LCD Alarming ,LCD display the zone number which isalarming

    1-16 is flashing Alarm panel at DelayARM state

    SET or Enquiry --is flashing Alarm panel at SET OR ENQUIRY state

    Display on LCD theGSM Signal, SIMcard Status andexternal telephone

    is OFF No singnal

    is ON GSM singnal good

  • 8/12/2019 KR-7016G Manual 20130515

    8/31

    line

    is OFF unload the SIM card

    icon display on LCD SIM Card loaded correctly

    is OFFNo connected the external telephone line

    icon display on LCDExternal phone line connected properly

    2.8 After receiving the Panel Alert

    After Panel alerts, it will automatically dial the preset telephone number for three times until connected. Whenthe user picks up the phone, a piece of pre-recorded voice message will be played back immediately and letthe receiver noted about the event. Upon receiving the call, it can also control the alarm panel remotely viathe phone (according to the command below). User will not be asked for password upon connected andalarm will automatically hang up call within receiving any instruction within 20 seconds.

    [1] key: arming [2] key: disarming

    [3] key: monitoring open [4] key: monitoring closed

    [5] key: turn on announcement [6] key: turn off announcement

    [7] key: siren ringing [8] key: stop siren sound

    [9] key: turn on relay [0] key: turn off relay

    [*] key: hang up, system will not dial the next number on list.

    Remark:If not hang up using [*] key or disarm using [2] key, the system will retry to call the next phone numbers on listuntil one connected.

    Panel will not ask for password when dialing out upon alarming.

    2.9 Remote Dialing In Operation:

    Remote-control operations can be done via any phone. You can just dial into the alarm panel and user will beasked for password upon connected and alarm will automatically hang up call within receiving any instructionwithin 20 seconds or password is incorrect three times. (original password 1234 )

    [1] key: arming [2] key: disarming

    [3] key: monitoring open [4] key: monitoring closed

    [5] key: turn on announcement [6] key: turn off announcement

    [7] key: siren ringing [8] key: stop siren sound

    [9] key: turn on relay [0] key: turn off relay

    [*] key: hang up,

    [#] key: Enter the system remote configuration mode, Without receiving no instruction, the panel willautomatically hang up after 20 seconds.

    3 system settings

    3.1Alarm Panel Initial Setup

  • 8/12/2019 KR-7016G Manual 20130515

    9/31

    Load the SIM Card, connect telephone line, fix the GSM Antenna, connect the power and other cables if any,

    then power up alarm panel. The alarm panel voice prompt "Welcome to use alarm system", and icon is

    display on LCD means searched GSM signals. icon is display on LCD too ,means GSM signals andSIM card are normal. LCD show "Phone line" indicates the external telephone line connection is good.

    icon is on means the external telephone line is well connected

    Upon everything working properly, the battery switch should be at the [ON] position for continuous charging.

    3.2 Pre-record Voice Message

    Alarm panel will play a pre-recorded voice message after the alarm call when a pre-set phone number uponalarm. To record customized message:

    Press "# "Key to enter the configuration mode:

    Then press 19# speak your message at the panel for recording

    System will record 10 Seconds and then automatically exit; or press any key to end whenever your messageend.

    Press *, then # exit setup status.

    3.3 Add Remote Control:

    Press "#" key to enter the configuration mode:

    Syntax: 07+(00~99)+# to configure remote control

    Example: 07 then press 01# , to configure the 1st group remote control. then press any key of the remotecontrol to send a signal to the alarm panel, panel beep twice means successful, beep only once means theremote control has been configured before. Alarm panel can configure up to 150 remote control of different

    addressing. Upon completion press # to exit the configuration mode, press * and then # exit the configurationmode.

    Remark: 01-99 means the group number of remote control ,one group can have one or more remotecontrol,Max can add 150pcs remote control to the alarm panel.

    3.4 Delete the remote control:

    Press "# "Key to enter the configuration mode:

    Syntax 1: 08+(00~99)+# to delete the remote control

    Syntax 2: 08+**+# to delete all remote controls

    Example: 08 then press 01# for deleting 1st remote control, then if you want to delete 8th remote control,press 08 instead of 01. Press # to exit the delete remote control, press * and then # to exit configurationmode.

    3.5 Add detector

    Press "# "Key to enter the configuration mode:

    Syntax: 09+(01~16)+# to add the detector

    Example: 09 then press 01# , to configure 1st sensor, then trigger the detector to send a signal to the alarmpanel. panel beep twice means successful, beep only once means the remote control has been configuredbefore. Alarm panel can configure up to 150 sensors of different addressing. Upon completion press # to exit

  • 8/12/2019 KR-7016G Manual 20130515

    10/31

    the configuration mode, press * and then # exit the configuration mode.

    Remark : 01-16 means the defence zone number

    3.6 Delete detector

    Press "# "Key to enter the configuration mode:

    Syntax 1: 10+(01~16)+# to delete the detector

    Syntax 1: 10+**+# to delete all detectors

    Example: 10 then 01#, to deleting sensor of 1st. If you want to delete the detectors of 6th, use 06 instead of 01. Upon completion press # to exit the configuration mode, press * and then # exit the configuration mode.

    3.7 Commands for Configuration

    This system supports three methods of configuration including the local keyboard, telephone set and SMSmessaging. Following are examples how instructions are given via one of the three methods of setting

    Example: you want to change the first phone number for voice calling to 13899998888:

    Method 1: At the KeyboardPress # to enter the configuration mode, and then press 3113899998888#, press the * then press # to exitconfiguration mode.

    Method 2: By telephone set

    Calling into the alarm panel, upon connected, alarm panel will ask for password, it is 1234 as the default,then press #, and then press 3113899998888# , press the * then press # to exit configuration mode.

    Method 3: Using SMS

    On your mobile phone, compose a SMS message as 12343113899998888# and send to your alarm panel.

    Below is a table of all commands supported.

    3.7.1 Set up voice alarmphone numbe r

    To set the 1st group to the 6th group of voice alarm phone number 1-6

    indicates that the first group to the Sixth group alarm number correspondingly.

    Example: If the user wants to set 13812345678 for the first set of voicealarm phone number

    Method one:

    After you press the # key to enter the configuration mode, press the

    3113812345678#, press * Then press # To exit Setup.Method two:

    Remote calling into the alarm panel put in password (initial password:1234 ) when being asked, then press the # key, hear the voice prompt andthen press 3113812345678#, press * then press # to exit the remotesetting status.

    Method three:

    Send SMS messages 12343113812345678# to a alarm panel (which at thebeginning of 1234 is the user password), the alarm panel will reply with

    SMS message "Group 1 phone number: 13812345678 to confirm the 1stgroup alarm phone number is set to13812345678 successfully.

    For users using the telephone line extension, you should dial a number

    Syntax:

    3 + 1-6 +Phone number + #

  • 8/12/2019 KR-7016G Manual 20130515

    11/31

    (such as "9") to pick up a dialing tone, then with your command you shouldadd to this number a " * ". So the completed command becomes9*13812345678#

    3.7.2 Delete voice alarmphone number

    Used to delete the first groups to the Sixth group alert phone numbers

    Example: If you want to delete the first set of telephone alarm number,

    Method one: After you press the # key to enter the configuration mode, press the 31#,then press * then press # to exit Setup.

    Method two:

    After entering the telephone remote setting status, press 31#.

    Method three:

    Send SMS message 123431# On the alarm panel, alarm panel reply "Group 1 phone number: to confirm the 1st group alarm phone number hasbeen removed.

    Syntax:

    3 + 1-6 + #

    3.7.3 Set phone number toreceive SMS message

    To set the first group to the sixth group of phone number for SMS message.When alarm panel is alert, it sends a SMS message to the six sets of numbers one by one.

    Example: If the user wants to set 13812345678 SMS for the first group of SMS message

    Method one:

    After press the # key to enter the configuration mode, press the4113812345678# , then press * then press # Exit Setup

    Method two:

    After calling and connected to the panel from remote, press4113812345678#

    Method three:

    Send SMS message 12344113812345678# to the panel.

    Syntax:

    4 + 1-6 + Phonenumber + #

    3.7.4 Delete SMS phonenumber

    Used to delete the first group to SMS of the Sixth group police number

    Example: If you want to delete the first set of SMS message phone number,

    Method one:

    After you press the # key to enter the configuration mode, press the 41# ,

    then press * then press # Exit Setup

    Method two:

    After calling and connected to the panel from remote, press41#

    Method three:

    Send SMS message123441#

    Syntax:

    4 + 1-6 + #

    3.7.5 Passwordmodification

    Used to modify the user password, the default user password is 1234

    Example: If you want to set up a new user password 4321

    Method one:

    Press # key to enter the configuration mode, press the 504321#, press the* then press # to exit setup.

    Method two:

    Syntax:

    50 + 4 digits newpassword 0000-9999 +

    #

  • 8/12/2019 KR-7016G Manual 20130515

    12/31

    After calling and connected to the panel from remote, press 504321#

    Method three:

    Send SMS message 1234504321#

    3.7.6 Set delay for systemarm

    Upon armed from the remote control or alarm panel, the alarm panel is setto delay 0 255 before at the ready status of ARM. The system default is

    000 seconds.Example: users need to set the delay time for 60 Seconds.

    Method one:

    Press # key to enter the configuration mode, press the 5160#, then press *then press # to exit setup.

    Method two:

    After calling and connected to the panel from remote, press 5160#

    Method three: Send SMS messages12345160#

    Notice: Set delay for system arm is in the 1-16zones.this only used when

    the zones change to Set delay for system arm zones, please check the(3.7.14) about the zones divided. Example, need change the 3 zones tothe delay alarm zone, set the delay time for 20 Seconds. Press # enter intosetting, press the 51020#, then press 600321#. Press the * then press # toexit setup.

    Syntax:

    51 + 000-255Second" + #

    3.7.7 Set the time of delayfor alarming

    Set the time of delay upon alarm, it can be set to 0-255 seconds; thesystem default is 000 seconds.

    Example: the user needs to set the alarm delay time to 60 Seconds.

    Method one:

    Press # Key to enter the configuration mode, press the 5260#, and press *then press # to exit setup.

    Method two:

    After calling and connected to the panel from remote, press 5260#.

    Method three:

    Send SMS message 12345260#

    Notice: Set delay for system arm is in the 1-16zones.this only used whenthe zones change to Set delay for system arm zones, please check the

    (3.7.14) about the zones partition. Example, want to change the 3 zones tothe delay alarm zone, set the delay time for 20 Seconds. Press # enter intosetting, press the 51020#, then press 600321#. Press the * then press # toexit setup.

    Syntax:52 + 000-255 Second

    + #

    3.7.8 Set length of Sirensound

    Set alarm length of sounding when panel alarm, could be set to 0-2default is 1 minute.Example: you want to make a siren sound 5 Minutes.Method one:# Key to enter the configuration mode, press the 5305#,* Then press # To exit Setup.Method two : After calling and connected to the panel from remote, press 5305#.Method three:

    Syntax:53 + 00-20 Minute " + #

  • 8/12/2019 KR-7016G Manual 20130515

    13/31

    Send SMS messages12345305#

    3.7.9 Set the scope of control of alarm panel andremote control

    Set which defense zone will be controlled by remote control and fromalarm panel keyboard. Factory default is all remote control andkeyboard can control all 01-16 zones.Remark:The 1 st remote control represented by number 01, ** represents the alarmpanel keyboard.Example: you want to set 01 remote control to control only 00-10 zone.Method one:# Key to enter the configuration mode, press 540111160#, and press * thenpress # to exit setup.

    Notice: 540111160# means close the 11-16zones that controlled bythe remote 1.as the remote 1 default 01-16 zones ,if let the 11-16 zones

    out off control, it can realize remote 1 only control the 1-10 zones.Method two:

    after calling and connected to the panel from remote, press 540111160#Method three:

    Send SMS message 1234540111160# Above is for continuous zones independent arm/disarm Function. To thediscontinuous zones to achieve remote control zones arm/disarm, thenaccording to the steps 2.Example: After set the remote 1 controlled the 1-10zones arm/disarm, butrequired 3zone and 7zone out of the remote 01 controlled .This time can

    close 01 remote for the 3zone and 7zone.Method one:# Key to enter the configuration mode, press 5401030#.then press5401070#.* Then press # To exit Setup.

    Method two: after calling and connected to the panel from remote, press5401030#, then press 5401070#.Method three: Send SMS message 12345401030# and 12345401070#.Notice: Reasonable use this remote control command can flexible to setthe remote control for the defense zones,Example: need the remote 1 to control the 1zones, press 540102160#,direct this command is ok. Also can press 540101160#, close all the zonesunder the remote 1 control, then press 5401011# to open the remote 1 tocontrol the zone 1.Example, need the remote 1 to control the 3zone and 8zone,press540101160# to close the 1-16 zones, then press 5401031#,5401081# toopen remote 1 to control the 3 and 8 defense zones. The command flexiblecollocation can set to the corresponding functions.

    Step 1 54 + Remote

    control number 01~99 + Starting defense area

    01~16 + End of defense zone 01~16 +

    arm/ disarm 0/1 + #

    Step 2:

    54 + Remotecontrol number 01~99 +

    defense area 01~16 ++ arm/ disarm 0/1 +

    #

    3.7.10 Set audibleconfirmation for remote

    control operation

    1 means on and 0 means closed, the default is on .Example: set panel without sound when remote control number 01 is

    sending signal.

  • 8/12/2019 KR-7016G Manual 20130515

    14/31

    Method one:Pressing # to entering the setup, and then press55010#, press * thenpress # to exit setup.Method two: After calling and connected to the panel from remote, press 55010#.Method three:

    Send SMS messages123455010#

    Syntax:55 + Remote control

    number 00~99 + 0/1

    + #

    3.7.11 Set date and timesettings

    Set the system date and timeExample: it is now 1 st of July of 2011 9 00 00 amMethod one:Press # to enter the configuration mode, press the 5620110701090000#

    press * then press # to exit Setup.Method two: After calling and connected to the panel from remote, press5620110701090000#.Method three:Send SMS message 12345620110701090000#

    Syntax:56 + 4-digits year +01-12 The Month +01-31 Day + 00-23

    Hour + 00-59 Minute + 00-59 Second " + #

    3.7.12 Scheduled arm anddisarm time setting

    To set the time for scheduled arm and disarm, it allows set at mostfour group of time for arm and disarm.Example: set up the first group scheduled time to arm at 22 00 pmand disarm at 07 00 am, this is valid for Monday, Tuesday, Wednesday,Thursday and Friday of each week.Method one:Press # enter the configuration mode, and then press57012200070012345#

    Example: set up the second group scheduled time to arm at 12 00and disarm at 13 00 pm, this is valid for all 7 days of each week.Method two:Press # enter the configuration mode, and then press5702120013001234567#, * then press # to exit Setup.Method three: After calling and connected to the panel from remote, press57012200070012345,then press5702120013001234567#Method forth:Send SMS message 123457012200070012345# and12345702120013001234567#Notice : If want to delete the first Scheduled arm and disarm time,Method one: Press # enter the configuration mode, press 5701**#,* thenpress # to exit SetupMethod two: After calling and connected to the panel from remote, press5701**#

    Method three: Send SMS message 12345701**#

    Syntax: 57 + Group number 01~04 + AAAA

    Scheduled time of arm + BBBB Scheduled

    disarmed time + Number week + #

    3.7.13 Scheduled arm and

    disarm zones settings

    Used to set when the four group of zone to be controlled by

    scheduled arm and disarm

  • 8/12/2019 KR-7016G Manual 20130515

    15/31

    Example: To set up the first group scheduled arm and disarm control 00-10defense zone.Method one:Press # enter the setup status and press 580111160#, press * then press# exit Setup

    Notice: 540111160# means close the 11-16zones that controlled

    by the remote 1.as the remote 1 default 01-16 zones, If let the 11-16 zonesout off control, that can realize remote 1 only control the 1-10 zones.Method two: After calling and connected to the panel from remote, press 580111160#Method three:

    Send SMS message 1234580111160# Above is for continuous zones independent arm/disarm function. To thediscontinuous zones to achieve remote control zones arm/disarm, thenaccording to the steps 2.Example: Already set the first group Scheduled arm and disarm

    1-10zones, but required 2 zones and 6 zones not be controlled. This timecan close the first group of the 2 zones and 6 zones.Method one:

    Press # enter the setup status, press 5801020# then press 5801060#,*then press # to exit Setup.Method two:

    After calling and connected to the panel from remote, press 5801020#then press 5801060#Method three: Send SMS message 12345801020# and 12345801060#

    Syntax: 58 + Group number

    01~04 + 01-16Defense zone begin the areacode + End of defensezone 01~16 + arm/

    disarm 0/1 + # Set mode of wired alarmzone

    3.7.14 Set the type of defense zone

    To set 16 zone type, 01-16 represents 1-16 zone number, 1-8represents one of the 8 zone type:

    1. NORMAL2. STAY ARM3. INTELLIGENT4. EMERGENCY5. CLOSED6. CHIME7. WELCOME8. HELP SENIOR

    The last 0/1 represents 0 siren of panel produce no sound upon alarmingwhile 1 is sounded.

    Notice; WELCOME and HELP SENIOR type siren not sound uponalarmingExample: Set zone number 8 as STAY EMERGENCY type, andsiren not sound upon alarming.

    Method one:Press # enter the configuration mode, press 600840#, press * then press #To exit Setup.Method two: After calling and connected to the panel from remote, press 600840#Method three:Send SMS message 1234600840#

  • 8/12/2019 KR-7016G Manual 20130515

    16/31

    3.7.15 Set mode of wiredalarm zone

    Set 2 wired alarm zone to NO or NC. The zone number of 11-12 arewired defense zones, system default is 11-12 are wired zones with NOmode.

    Syntax:61 + wired zone

    number 11-12 + 0/1

    + #

    0 means NO and 1 means NC NO means short-circuit to alarm NC means open-circuit to alarm

    Example: Set 11 zone to NC,Method one:# Key enters the configuration mode, press 61111#* Then press # To exit Setup.Method two:After calling and connected to the panel from remote, press 61111#Method three:Send SMS message 123461111#Remark: On the back pane of the alarm panel11 = Z1112 = Z12

    3.7.16 Set RemoteOperation on or off Syntax:

    62 + 0/1 + #

    These enable or disable the remote operation of alarm panel usingtelephone. System default is on.Example: turn off the remote setting function,Method one :#, and then press 620#, * then press # To exit Setup.Method two :After calling and connected to the panel from remote, press 620#Method three:

    Send SMS message 1234620# Notice: close the remote setting function, the host still can according tothe telephone remote answering ringing and input the correct password,you can press 1 on remote arming, press 2 disarming, just press # whenthe host wouldn't tell setting, and not enter the remote setting function.

    3.7.17 Assign specificphone number to certainzone

    System default is all 01-16 defense zone will make call from the firstto sixth group phone number upon alarming.Example: user needs 01-10 to call the first, second, third set of numbers.

    Method one:# , and then press 630110123#Example: users need to 11-13 zone alarm the fourth, the fifth and thesixth group number.Method one:# , And then press 631113456#Example: User need the zone 14 call only the 5th group number.Method one:# , and then press 6314145#.Method two:

    After calling and connected to the panel from remote, press630110123# , then press 631113456# , then press 6314145# .Method three:

    Syntax:

    63 + 01-16Defense zone begin thearea code + 01-16Defense zone ends areacode + Police groupnumber 123456 +

    #

  • 8/12/2019 KR-7016G Manual 20130515

    17/31

    Send SMS message 1234630110123# , and 1234631113456# , and12346314145#

    3.7.18 Settamper device ON/OFF

    System default is 1 tamper device ONExample:Method one: press #, then press 720#.Method two: After calling and connected to the panel from remote,

    press 720#Method three: Send SMS message 1234720#

    Syntax:72 + 0/1 + #

    3.7.19 set remote andkeyboard for stay defensezones to controlarming/disarming

    Set stay defense zones.0 is disarming,1 is arming,.system default all theremote and keypoard arming to 01-16 defense zones.The 1st remote control represented by number 01, ** represents thealarm panel keyboard.

    Syntax one: 77 + Remote control

    number 01~99 + Starting defense area

    01~16 + End of defense zone 01~16 +

    arm/disarm 1/0 + #

    Syntax two: 77 + Remote control

    number 01~99 + defense area number

    01~16 + arm/disarm1/0 + #

    Example: to set stay of remote control of group 1 to disarm for 01~05 zones

    and arm for 6~16 zonesMethod one: Press #, then press 770101050#, press * then press # To exitSetup.Method two: After calling and connected to the panel from remot770101050#Method three: Send SMS message 1234770101050#The above is for continous zones,to set stay for discontinous zones.thenfollow the step 2.Example: if already set remote control number 01 to disarm zones 01~05and arm zones 6~16, Well, if aslo need arm zone 02 and zone 04, then canset No.1 remote to control zone 02 and 04 separately.Method one: Press #, then press 7701021#, and then press7701041#.press * then press # To exit Setup.Method two: After calling and connected to the panel from remote, press7701021#,and then press 7701041#Method three: Send SMS message 1234770101050#,and 12347701041#Remark: number of stay zones should less than the arm/disarm zones of the remote control, for example, if No.1 remote control arm and disarmzones 01~10, then stay zones should choose from zones 01~10.

    3.7.20 System voicevolume adjustment

    Valid value is from 1 to 7 as largest, system default is 5.Example: users need to set volume to 3

    Method one:# , and then press793# , press the * then press # Exit SetupMethod two : After calling and connected to the panel from remote, press 793#Method three:Send SMS message 1234793#

    Syntax:84 + 0/1 + #

    3.7.21 Power save modeON /OFF

    Used to control the energy saving mode on or off ,0 means off ,1means on

    ON means when alarm host in standby state ,it would be auto off the LCDdisplay after 20s,enter the power saving mode.

    OFF means when alarm host in standby state ,the LCD display would stay

    Syntax:84 + 0/1 + #

  • 8/12/2019 KR-7016G Manual 20130515

    18/31

    on with time display .Example: users want to close the LCD display .Method one :Press # enter the configuration mode, and press 840# * then

    press # To exit Setup.Method two: After calling and connected to the panel from remote, press840#Method three: Send SMS message 1234840#

    3.7.22 Built-in Siren volumeadjustment

    Valid value is from 0 to 7 as largest, system default is 5.Example: users need to set volume to 3

    Method one: press # , and then press 873# , press the * then press # ExitSetupMethod two : After calling and connected to the panel from remote, press873#Method three: Send SMS message 1234873#

    Syntax:87 + 0-7 + #

    3.7.23 Set audibleconfirmation from panel to

    on or off

    Alarm panel will produce audible confirmation beep upon receipt of signal from remote control. 1 is on, 0 is off, default is on.

    Example: users need to disable the audible confirmation.Method one:# then press 110# , press the * then press # Exit SetupMethod two: After calling and connected to the panel from remote, press 110#Method three:

    Send SMS messages1234110#

    Syntax:11 + 0/1 + #

    3.7.24 Enable or disable theSMS Messaging

    1 is on and 0 is off. Default is onExample: the user will need to turn off the text messaging feature

    Method one:# Then press 120# , press * then press # exit setup statusMethod two: After calling and connected to the panel from remote, press 120#Method three :Send SMS message 1234120#

    Syntax:12 + 0/1 + #

    3.7.25 Enable or disable of the anti-tampering of telephone cord

    Cut the phone cord will trigger the alert. 0 is off and 1 on, systemdefaults to closed.Example: user need to enable anti-tampering of telephone cord featureMethod one:

    Press # Then press 131#, * then press # to exit SetupMethod two: After calling and connected to the panel from remote, press 131#Method three:

    Send SMS message 1234131#

    Syntax:13 + 0/1 + #

    3.7.26 External sirenvolume adjustment

    Valid value is from 00 to 99 as largest, system default is the largest.Example: users need to set volume to 50

    Method one:# , and then press 1450# , press the * then press # Exit Setup

    Method two : After calling and connected to the panel from remote, press 1450#Method three:

    Send SMS message 12341450#

    Syntax:14 + 00-99 + #

  • 8/12/2019 KR-7016G Manual 20130515

    19/31

    3.7.27 Forced disarm frompanel keyboard

    Upon alarming, enforced to use only the panel keyboard to disarm(remote control is not allowed) for extra security. 1 is on and 0 is off ,the system default is off Example: user needs to enforce to use keyboard.Method one :# , and then 151# , press the * then press # Exit Setup

    Method two: After calling and connected to the panel from remote, press 151#Method three:

    Send SMS message 1234151#

    Syntax:15 + 0/1 +

    #

    3.7.28 Turn on or off Interference Alert

    This set the alarm panel to sound for 5 seconds upon a kind of malicious attach from un-authorized remote control or transmitter of same frequency, meanwhile, the alarm panel will display tP warning.Example: users need enable interference alertMethod one:# , and then press 161# , press the * then press # Exit SetupMethod two : After calling and connected to the panel from remote, press 161#Method three:

    Send SMS message 1234161#

    Syntax: 16 + 0/1

    + #

    3.7.29 Keyboard passwordprotection feature

    To enable the password protect of keyboard. System default

    password is 1234, defaultis set to off. Alarm panels will display " "

    when keyboard is lockedExample: keyboard users need to set the password protection.

    Method one:# , and then press 171# , press the * then press # Exit SetupMethod two: After calling and connected to the panel from remote, press 171#Method three:

    Send SMS message 1234171#

    Syntax: 17 + 0/1 +

    #

    3.7.30 Set number of ringtones before picking up

    The system default is 8. 00 means the remote operation is notallowed and disabledExample: the user needs to set up a number of rings before picking up to 6.

    Method one:# , and then press 1806#Example: the user needs to set off the remote number ring.Method one:# , and then press 1800# , press the * then press # Exit SetupMethod two: After calling and connected to the panel from remote, press 1800#.Method three:

    Send SMS message 12341800#

    Syntax:

    18 + 00 20 + #

    3.7.31 Set integratedalarming

    Enable or disable the integrated alarm upon alarm. 1 is enabled and 0 isdisabled, the system default is 1.Example: users need to set the integrated alarming off,Method one:

    Syntax: 20 + 0/1 + #

  • 8/12/2019 KR-7016G Manual 20130515

    20/31

    # , and then press 200# , press the * then press # Exit SetupMethod two: After calling and connected to the panel from remote, press 200#Method three:

    Send SMS message 1234200#

    3.7.32 Restore factory

    setting

    System restore factory setting

    Method one:# , and then press 9898#Method two: After calling and connected to the panel from remote, press 9898#Method three:Send SMS message 12349898#Remark:This feature will restore all settings to factory default apart from theconfiguration of sensors and remote control.

    Syntax: 9898 + #

    3.7.33 Total System Rese t Disconnect power to the alarm panel, turned off the battery switch alarmpanel, then press and hold the alarm panel of ARM button while power-on.The system will respond with short beep slowly for 5 seconds, then canrelease ARM button. The system is now totally reset. All configuration hasbeen cleared, all sensors and remote controlled are deleted and passwordis restored to original 1234.

    Syntax:Press and hold the ARMbutton on the keyboardand power on.

    Note: Other than the SMS commands for assigning specific phone number for certain zone, alarm panel willrespond to all other SMS commands by replying confirmation of setting by SMS.

    3.8 Commands for Alarm center

    3.8.1 Set up alarm cennumber

    To set the 2 group of alarm center number 1-2 indicates that the first gr to the second group alarm center number correspondingly.Example: If the user wants to set 075588556688 for the first set of voice alphone number Method one:Press # key to enter the configuration mode, press the 4107558855668then * then press # to exit setup.Method two:

    After calling and connected to the panel from remote, pr 41075588556688#Method three:Send SMS message 123437075588556688#

    Syntax: 3 + 7-8 + phone numb

    + #

    3.8.2 Delete alarm cennumber

    Used to delete the first groups to the second group alert phone numbExample: If you want to delete the first set of telephone alarm number,Method one: After you press the # key to enter the configuration mode, press the 37#, tpress * then press # to exit Setup.

    Method two: After entering the telephone remote setting status, press 37#Method three:

    Syntax: 3 + 7-8 + #

  • 8/12/2019 KR-7016G Manual 20130515

    21/31

    Send SMS message 123437#

    3.8.3 Zone settingTo set the CID feature codes of 1-16 defence zone ,the default 130 is stealin01-16 means 1-16 defence zone. AAA means CID feature codes

    100 is medical aid

    110 is fire alarm

    121 is robbery alarm

    122 is mute robbery alarm

    130 is burglary alarm

    131 is peripheral burglary alarm151 is gas alarmExample: users need to set the sent fire alarm message to alarm center wsecond defence zone alarming.Method one: Press # then 6402110# ,press the * then press # Exit SetupMethod two: After calling and connected to the panel from remote, pr 6402110#Method three: Send SMS message 12346402110#

    Syntax: 64 + 01-16 zone numbe

    AAA CID feature codes +

    3.8.4 Set the mode of uploadiarm/disarm message

    When alarm panel connect with the alarm center ,to set whether needupload the arm /disarm status or not ,the default is not .1-4 represent 1 Upload the arm message

    2 Upload the disarm message3 Upload the arm and disarm message4 Don't upload any message

    Example :Don't upload any message of arm //disarm to the alarm center ,Method one : # ,and then press 194# ,press the * then press # Exit SetupMethod two: After calling and connected to the panel from remote, pr 914#Method three:Send SMS message 1234914#

    Syntax:

    91

    +

    1-4

    +

    #

    3.8.5 Set CID center account

    CID center account setting ,the center account is 4digital ,can be0000-99999.The default is 0000Example :want to set the CID center account as 1234.Method one : # ,and then press 921234# ,press the * then press # ExitSetupMethod two: After calling and connected to the panel from remote, press 921234#Method three:Send SMS message 1234921234#

    Syntax: 92 + 0000-9999 + #

    3.8.6 Scheduledself-checking setting

    Enable or disable the scheduled networking self-checking function ,thisalarm system need to self-checking at regular intervals ,to confirm thealarm panel and the alarm center connection properly.Default is disable .

  • 8/12/2019 KR-7016G Manual 20130515

    22/31

    0/1 represent 0 closed ,1 self-checking at actual timeRemark: Actual time is your setting ,you can set two groups of scheduledself-checking . 57 + 07 + AAAA the first group self-checking time+ AAAA the second group self-checking time + number week + #Example: open the self-checking function ,self-checking once time at03:00am every day.

    Method one: # ,and then press 931#,and press 5707030024001234567# .Remark : Here 2400means closed the second group self-checking time.

    Example:open the self-checking function ,self-checking once time at02:00am every Wednesday .

    Method one :# ,and then press 931# and 5707020024003#Method two :After calling and connected to the panel from remote,press931# and 5707030024001234567# /5707020024003#

    Method three:

    Send SMS message 1234931#,and then send SMS message12345707030024001234567#/12345707020024003#

    Syntax: 93 + 0/1 + #

    3.9 Commands of System EnquiriesPress Query button on panel to enter the query mode Then put in commands as detailed in table below, whenfinished, Press *, and then press #, to exit the query mode.Note: In case keyboard password protection is enabled, please enter tne password to unlock before other commands.

    Query for CID voice alarmphone number

    To query the alarm panel currently saved to the first set to the Eighthgroup CID voice alarm phone number.

    Press alarm panel query key of your keyboard, and then press 31#, thealarm panel LCD show 13812345678 means alarm panel's first set of alarm numbers are 13812345678

    Syntax3+ 1-8 + #

    Query SMS messagealarm phone number

    To query the alarm panel currently saved to the first set to the sixth groupphone number on the alarm panel for SMS messages.Press alarm panel query key of your keyboard, then press 41#, the alarmpanel LCD show 13812345678 means the first set of SMS message is13812345678

    Syntax4+ 1-6 + #

    Query passwordUsed to query the current password of the alarm panel , Press alarmpanel query key of your keyboard, then blinking status LED on and thenpress 50#, the alarm panel LCD show 1234. alarm panel your currentpassword is 1234 . Press # to clear the screen, press * then press # to exitthe query mode.

    Syntax50 + #

    Query the time for delayarm

    Query delay time for arm (000-255) SecondsPress alarm panel query key of your keyboard, then blinking status LED

    on and then press 51#, the alarm panel LCD show 000 mean time for delay is 0 second.

    Syntax51 + #

    Query the time for delay (000-255)

  • 8/12/2019 KR-7016G Manual 20130515

    23/31

    arm 52# LCD 000.

    0 To query the alarm delay time (000-255) SecondsPress alarm panel query key of your keyboard, then blinking status LEDon and then press press 52#, the alarm panel LCD show 00 mean time for delay is 0 second.

    Syntax52+ #

    Query siren sounding time

    for alarming

    To query the siren sounding time (00-20) minutes when the alarming.

    Press alarm panel query key of your keyboard, then blinking status LEDon and then press 53#, the alarm panel LCD show 01 mean time for delayis 1 minute.

    Syntax53+ #

    Query remote control andkeyboard assignments to zone

    For query of specific remote control and keyboard assignments to zone00-99Press alarm panel query key of your keyboard, then blinking status LEDon and then press 5401#, the alarm panel LCD show 00-99 and remotecontrol 1 means remote control 1 is controlling zone 00-16, press # clear screen, using 5402# for query remote control 2 and so on.

    Syntax54+ 01-99 + #

    Query remote control audibleconfirmation

    For query the setting of remote control 00-99 for the audible confirmationto command.Press alarm panel query key of your keyboard, then blinking status LEDon and then press 5501#, the alarm panel LCD show ON means remotecontrol 1 is set to sound upon receipt of command.

    Syntax55+ 01-99 + #

    Query the scheduled time for arm and disarm

    Used to query first to fourth set of scheduled time for arm and disarm.Press alarm panel query key of your keyboard, then blinking status LEDon and then press 5701# to query the first of scheduled arm and disarm,the alarm panel LCD show Mon, Tue, 22-00 07-00 means schedule set

    as Monday and Tuesday 22:00 pm arm and 07:00 am disarm.

    Syntax57+ 01 04 + #

    Query the zone number withscheduled arm and disarm

    For query the first to the fourth group scheduled arm and disarm.Press alarm panel query key of your keyboard, then blinking status LEDon and then press 5801# for zones with the first group of zone, the alarmpanel LCD show 00-16 means 0-16 zone are with 1 st number group.

    Syntax58+ 01 04 + #

    Query type wireless defensezone

    For query the zone types of 00-16.The alarm panel LCD show the name of type of zone, detail about zonetypes can be referred to another section of manual, the word ON or OFF next to the zone type represents whether siren will sound uponalarming.

    Syntax60+ 01-16 + #

    Query the type of wired zones For query the zone type of 11-12.Example: Press alarm panel query key of your keyboard, then blinkingstatus LED on and then press 6111# to query 11 zone alarm type, showON means short-circuit to alarm while show NC means open circuit toalarm.

    Syntax61+ 11-12 + #

    Query remote operation on/off To query if the remote operation is allowed, it should show either ON or OFF.Syntax

    62+ #

    Query phone number for specific zone

    To query the phone number assigned to zone 00-16 for alert.Example: Press alarm panel query key of your keyboard, then blinking

  • 8/12/2019 KR-7016G Manual 20130515

    24/31

    status LED on and then press 6301# for zone 1, the alarm panel LCDshow 123456 means these 6 group of phone numbers are assigned to 01zone. If shows 34, means 3 and 4 group

    Syntax63+ 01-16 + #

    Query anti-forced openon/off

    Query anti-forced open on/off ON means enable OFF meansdisable

    Syntax 72+ #

    Query the voice alarmvolume of system

    Query the voice alarm volume of system. Press query on keyboard,press 79#, display 7 means max volume, 1 menas min volume

    79+ #

    Query the volume of built-insiren

    Press query on keyboard, press 87#, display 7 means max volume,0 menas silent

    87+ #

    Query for the setting of alarmaudible confirmation

    ON OFFFor query whether the alarm will play audible confirmation upon receipt of commands. It shows either ON or OFF.Syntax

    11+ #

    Query the setting of anti-tampering of telephoneline

    ON OFFFor query whether the anti-tampering of telephone line is set, it showseither ON or OFF.

    Syntax13+ #

    Query sound volume of siren Query for the volume level of siren, it shows between 00-99 representingthe 00 as lowest and 99 as highest volume.

    Syntax14+ #

    Query for the setting of enforced keyboard disarm

    ON OFFTo query whether enforcing the disarm from keyboard upon alarming. Itshows either ON or OFF.

    Syntax15+ #

    Query of the setting of interference alert

    To query whether interference alert is set, it shows either ON or OFF.

    Syntax16+ #

    Query keyboard passwordprotection

    To query if the password protection feature is enabled, it shows either ONor OFF.

    Syntax17+ #

    Query of number of ringsbefore panel pick-up incomingcall

    To query the number of ringing before the panel will pick up incoming callsfrom remote. (0-20 times)Example: Press alarm panel query key of your keyboard, then blinkingstatus LED on and then press 18#, it shows 08 means 8 rings, 11 means11 rings and so forth.

    Syntax18+ #

    Query the setting of integrated To query whether the integrated alarming of the alarm panel is set. It

  • 8/12/2019 KR-7016G Manual 20130515

    25/31

    alarming shows either ON or OFF.

    Syntax20+ #

    Query if GSM Module isenabled

    Query if GSM Module is enabled or disabled, ON is enabled and OFF isdisabled.

    Syntax21+ #

    Query alarm panel arm/disarmrecords

    The system can save up to the most recent 72 disarmed records.Press alarm panel query key of your keyboard, then blinking status LEDon and then press 9901#, press 8 to scroll up and 0 to scroll down for records. Other indications as:JP = arm/disarm from keyboardYC = arm/disarm from remotetP = interference alert01 = remote control number 1

    Syntax9901+ #

    Query alarm panel alarmingrecords

    The system can save up to the most recent 102 alarming records.Press alarm panel query key of your keyboard, then blinking status LEDon and then press 9901#, press 8 to scroll up and 0 to scroll down for records.Example: Screen shows 01-01 22-02 02 alarm, which means alarmhappened on 1 st January 22:02pm at zone 2.

    Syntax:9901+ #

    3.10 SMS Commands

    following instructions are only for SMS command to control panel remotely:1234

    3.10.1 Remote SMS disarm Send SMS message 12340# into alarm panelNote: 1234 is the password0#

    3.10.2 Remote SMSNORMAL arm

    Send SMS messages 12341# to set the alarm panel to ARM

    1#

    3.10.3 Remote SMS STAYarm

    Send SMS message 12342# to set alarm panel to STAY ARM.

    2#

    3.10.4 Remote SMS turn onrelay

    Send SMS message 12343# to turn on the relay of the alarm panel

    3#

    3.10.5 Remote SMS turn off relay

    Send SMS messages 12344# to turn off the relay of the alarm panel

    4#

    3.10.6

    queryarming/disarming, power and relay status

    send SMS 12345# to panel panel reply:

    Disarmingarming zonedisarming zone 1 2 3 4 5 6 7 8 9 10 11 12 13 1415 165#

  • 8/12/2019 KR-7016G Manual 20130515

    26/31

    AC power onRelay output off

    3.10.7 Query the alarm panelgeneral settings

    Send SMS message 123411# to the alarm panel, the alarm panel replieswith a list of related setting:

    11 voice on12 SMS messaging on

    15 Forbid disalarming off 16 Interference checking off 17 keyboard not lock20 Integrated Alarming on62 Remote setting on72 anti-forced open on84 Power saving on

    11+ #

    3.10.8 Query anti-tamperingof phone cord and number of

    rings before pick-up

    Send SMS message 123413# to the alarm panel, the alarm panel replieswith a list of related setting:

    Telephone line disconnection detection off Phone ring:08

    Means: Telephone detection off, and the number of rings before pick-up is8

    13+ #

    3.10.9 Query system setting Send 123414# to panel, panel reply:14 Siren Volume 9950 password123451 arming delay 00052 alarming delay 00053 siren alarming 0179 system volume 0587 built-in siren volume 05

    14+ #

    3.10.10 Query voice alarmphone number

    Return a list of 1 st to 8 th phone number group for voice alarm.Example: Send 12343001# to the alarm panel, the alarm panel replies "(31)Group 1 phone number: 13712345678 means the (30)first voicealarm phone number is 13712345678, CID means alarm centersnumber

    30+ 01-08 + #

    3.10.11 Query phone number for SMS message

    Query first to sixth group of phone number for SMS message.Example: Send 12344001# to the alarm panel, the alarm panel replies

    "Group 1 SMS number: 13888889999 means alarm the 1 st phone number for SMS message is 13888889999.

    40+ 01-06 + #

    3.10.12 Query assignment of remote control to defensezone

    Query the assignment of remote control to specific defense zoneExample: Send 12345401# to the alarm panel, the alarm panel replies: 01remote control zone range:00-16,Keyboard zone range:00-16 means 01remote control is assigned to control zone 00-16. and keyboard isassigned to control zone 00-16.

    54+ 00-99 + #

    3.10.13 Querying alarm panelsystem time

    Query alarm panel system timeExample: Send 123456# to the alarm panel, the alarm panel repliesSystem clock :2011-07-01 12:00. Means the system is now 1 st of July of 2011 12 00 00 am.

    56+ #

  • 8/12/2019 KR-7016G Manual 20130515

    27/31

    3.10.14 Check the status of scheduled arm/disarm

    Query the four group of the scheduled arm and disarmExample: 12345701# to the alarm panel, the alarm panel replies:Group 1 timing: Arm time:22:00Disarm time:07:00 Arm/Disarm week:12345

    Zone range:00-16Means: the first group scheduled time to arm at 22 00 pm and disarmat 07 00 am, this is valid for Monday, Tuesday, Wednesday, Thursdayand Friday of each week. control 00-16 defense zone

    57+ 01-04 + #

    3.10.15 Check the type andsiren setting of wirelessdefense zone

    01 99 12346001# 01

    CID 130 1

    Query the type and siren setting of certain wireless defense zoneExample: Send message 12346001# to the alarm panel, the alarm panelreplies01 zone is wireless zone, zone type: normal; siren ON

    60+ 00-99 + #

    3.10.16 Check the settings of wired defense areas

    Query the alarm panel for settings of zone 11 12 wired zone.Example: send text message 12346111# to the alarm panel, thealarm panel replies11 zone is wired zone, zone type : normal;siren ON; alarm type: NO

    61+ 11-12 + #

    3.10.17 Query phone number assignment to zone

    Query the alarm panel the phone number assigned to zone 00-16.Example: send message 12346301# to the alarm panel, the alarm panelreplies01 zone dialing group number:123456 means zone 1 will dial

    phone group 123456.63+ 01-16 + #

    3.10.18 Customize the SMSmessage for certain zone

    Used to customize the SMS message for zone 00-16 to 1-6 groups SMSphone number number.Example: Send message 12348001 Front Door Alarm# to the alarmpanel will set alarm panel to send SMS message Front Door Alarm uponzone 01 alarm being triggered to 6 groups SMS number.Note: Maximum length of message is 25 characters.

    80+ 01-16 + zonemessage + #

    3.10.19 Query the customizedSMS message content

    Query zone 00-99 the content of SMS message customized.Example: Send 12348101# to the alarm panel to query for zone 01

    message content.81+ 01-16 + #

    3.11 Calling Function:

    1. Through SIM card.When Using China mobile SIM Card, on the keyboard, put in #00 10086# where 10086 is the phone number youre going to connect. Can press the related number key to operate when heard voice option, At the end of your call, press DISARM key, press *, then press # to exit.When Using China Unicom SIM card, on the keyboard, put in #00 10010# where 10010 is the phone number youre going to connect. Can press the related number key to operate when heard voice option, At the end of your call, press DISARM key, press *, then press # to exit.

    2 Through Landline 1 phone number+#

  • 8/12/2019 KR-7016G Manual 20130515

    28/31

    On the keyboard, put in #00 1000# where 1000 is the phone number youre going to connect. Can press therelated number key to operate when heard voice option, At the end of your call, press DISARM key, press *,then press # to exit.

    3.12 Definitions of Zones

    The alarm supports 16 distinguishable defense zones and they can be classified into one of the 8 Zone

    Types with their respective characteristics.

    Type ID Zone Type Interpretation

    1 NORMAL DefenseZone

    the Panel only works on the arming status. When disarming, there is noresponse.

    2 STAY Defense zone(AT-HOME Defensezone)

    can be shut off solely through the remote control (keyboard) to avoidthe Infrared Detectors and other in-room detectors from misinformationwhen master is resting at home.

    3 INTELLIGENT

    Defense zone:

    if the detector in the Defense zone is triggered only once, it will not

    immediately alarm. But if being triggered once again within 30 secondsafter the first triggering, it will alarm immediately.

    4 EMERGENCYDefense zone:

    no matter on arming or disarming status, if detector is triggered it willalert. Usually used in connecting with Smoke Detectors, Gas Detectorsand emergency button, etc.

    5 CLOSED Defensezone:

    no matter arming or disarming status, detectors will not alert evenbeing triggered.

    6 CHIME Zone No matter in what status, when sensor with this zone is triggered, awelcome door bell will be ring as notification.

    7 WELCOME Zone Only work on the arming status, when sensor with this zone istriggered, a welcome voice message will be played.

    8 HELP SENIORDefense Zone

    This type of zone is for elderly safety, no matter in what status, thepanel will alarm once sensor with this zone type is triggered.

    System default zone types are:

    Normal Intelligent Help Senior Chime Welcome Emergency

    01-08 11~12 09 10 13 14 15-16

    3.13 Other System DefaultOperationpassword

    1234 Forced disarm from panel keyboard off

    Remote Control Enable Integarted alarming Enable

    Siren sound 1 minuteNumber of ring tones before picking

    up8 times

    Delay ARM 0 s Audible confirmation for remote

    operationEnable

    Cut-line detect Off Delay alarming 0s

    11-12 wiredzones

    Short circuitalarming on

    1-16 zone alarming Siren sound

    SMS message Enable 1-16 Zone SMS message content Zone alarm

  • 8/12/2019 KR-7016G Manual 20130515

    29/31

    3.14 Fitting parameters:

    - Input voltage: DC9V-12V- Standby currents: < 25 mA- Alarm current: 450 mA

    Wireless frequency: 315/433/868/915MHZ 2262/1.5-4.7M EV1527/150K-470K- GSM Format: Support GSM850/900/1800/1900MHz (option)

    Backup battery: NI-HI AAA*6 DC7.24V Alarm loudness: 110dB

    - Detailed parameters: The alarm should be compatible with PT2262, PT2240 and EV1527. Using PT2262encoding, the resistance is recommended 1.5M-4.7M; using with EV1527 encoding, the resistance by300K, data recommended 1010.

    4. Guideline of Installation Sensors and Troubleshooting

    4. 1 Guideline for Installing Door or Window Sensor

    1. The surface for door sensor installation should be clean so door sensor can be attached to the door andframe firmly with double faced adhesive.

    2. Each door sensor is a pair of sensor and magnet. The sensor (A as in diagram) should be installed on thefixed door frame and the magnet (B as in diagram) should be placed on the movable door with a distance

    not exceeding 1 cm.3. Upon installed, door sensor should be tested by open the door and check if the indicator on door sensor

    flashes for 1 second.4. In case the door sensor is running out of battery, the indicator should be kept lit as a low-voltage

    notification.

  • 8/12/2019 KR-7016G Manual 20130515

    30/31

    4.2 Guideline for Installing PIR Motion Sensor

    1. Before use, make sure the power switch of PIR motion sensors is at the ON position.2. Installation height is about 2.2 meters above ground and the optimized detection angle for most motion

    sensor is 90 degree. The sensor should face the detected area with this consideration for best coverage.

    It is advised to install with the face of motion sensor perpendicular to the most probable moving detectionof people for the highest effective detection.

    3. Within coverage of detection, there should be no any objects for obstruction.4. There should be no two infrared detectors in the same as they will possibly intervene with each other.5. Avoid the detector facing window, cooling or warming machines, or other appliances that cause the

    temperature changing sharply and thus cause false alarm.6. Most infra-red detector needs about 5 minutes to heat up before READY for normal operation.7. Regular PIR motion sensor is for indoor use unless the specification stated otherwise.

    Unless specifies otherwise, most infra-red detector are indoor use and not reliable to use outdoor.

    4.3 Troubleshooting

    Troubleshooting Reasons Methods

    Host don't read SIMcard or GSM alarmdon't dial the phoneor don't textmessages

    1. SIM card unloaded2. SIM card is setting PIN code3. GSM signal weak4.does not have a voice alarmnumber

    5. did not set SMS messagesreceiving alarm number 6. mobile phone card balanceshave insufficient or validity7.no open SMS messagesfunction

    1.load SIM card2.cancel PIN code3.change to place with strong signal or addingoutdoor GSM antenna4. set the voice alarm number 5.set the SMS messages receiving alarmnumber 6. mobile phone card prepaid phone callcharges7.enable SMS messages function

    Cant long-distanceoperation

    password input wronglypassword input or changed to new password Or forced always clear factory set back

    no record indicationwhen alerting

    alert record un-recordedrecord alerting re-record according to the

    specification

    remote controller outof order

    1. coding unmatched with thehost2. insufficient power

    1. re-coding2. change battery in the same type3. eliminating the dirt on the pieces caused by

  • 8/12/2019 KR-7016G Manual 20130515

    31/31

    3. battery pieces poor contact or corroded4. unmatched with host

    corrosion4. contact the local dealer to change the

    matched remote controller

    infrared detector outof order

    low power change to the same type battery

    siren without sound

    1. siren plug or jack in short

    circuit or broken-line2. plug line in short circuit3. siren closed

    1. repair or change plug or jack2. change the jack line3. set siren ringing time on the host

    The distance for hostto receive theinfrared detector,door status switchand remotecontroller isshortened

    1.a nearby emitter is sendingcode2. host receiver stoppage3.standby battery of the hostinsufficient

    1.find the interfering source and eliminate it2.post back to the factory for amendment3.check host power whether plugged well

    Buttons failureOpen password keyboardprotection function

    Closed password keyboard protection function

    Host no voice promptShut down voice promptfunctions

    Open voice prompt functions