New Drywall and Floor Systems Knauf alutop ® Access Panels Standard Access Panels – REVO for Ceilings, Drywall Partitions, and Furrings Fire-Resistant Access Panels – F-TEC for Ceilings, Installation Shaft Walls and Solid Walls – FIRE PROTECTION for Ceilings, Drywall Partitions and Shaft Walls Acess Door – ACESS DOOR for Walls and Jamb Walls Special Access Panels – AIRTIGHT and DUST-PROOF – DISINFECTANT-RESISTANT Knauf alutop ® REVO 12.5 / 18 Variant / 25 Variant Knauf alutop ® F-TEC Fire-Resistant Access Panels 2008-02

Upload: others

Post on 28-Jan-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

  • New

    Drywall and Floor Systems

    Knauf alutop® Access Panels Standard Access Panels – REVO for Ceilings, Drywall Partitions, and Furrings

    Fire-Resistant Access Panels – F-TEC for Ceilings, Installation Shaft Walls and Solid Walls

    – FIRE PROTECTION for Ceilings, Drywall Partitions and Shaft Walls

    Acess Door – ACESS DOOR for Walls and Jamb Walls

    Special Access Panels – AIRTIGHT and DUST-PROOF

    – DISINFECTANT-RESISTANT

    ■ Knauf alutop® REVO 12.5 / 18 Variant / 25 Variant■ Knauf alutop® F-TEC Fire-Resistant Access Panels

    2008-02

  • Ar-na-fett 12,6 mm

    Ar-na-fett 12 mmb b

    (Ar-na-light 11 mm

    Hinweis Auf Anfrage ist eine differenzierte Bemessung der Deckenunterkonstruktion möglich.

    Ar-na-fett 12 mm

    Ar-na-fett 12,6 mmAr-na-light 12 mm

    Ar-na-fett 12 mm Ar-na-light 12 mm

    *) Ar-na-light 11 mm

    *) Ar-na-light 11 mm

    Ar-na-light 11 mm

    Ar-na-light 11 mm

    Gerade Rundlochung 8/18 RDurchlaufende Lochungen

    Ar-na-light 11 mm

    Ar-na-fett 12 mm

    Ar-na-fett 12,6 mm

    c

    Frag

    en ?

    ?? F

    rage

    n ??

    ??

    Text Text TextText Text Text

    Text Text TextText Text Text

    Knauf alutop® Access PanelsContents

    Product Overview 3

    Surfaces are being subjected to ever more stringent demands. Knauf alutop® Standard Access Panels REVO satisfy requirements of this type for cladding thickness from 12.5 mm to 25 mm – in any location where there are no building physical requirements. The flush bonded Dia-mant board allows for flawless surfaces with minimal effort.

    REVO 4

    Fire-Resistant - one single type for all occasions Knauf alutop® Fire-Resistant Access Panels F-TEC One type of panel, universally usable for ceilings, shaft walls, or in solid walls and for cladding thickness up to 25 or 50 mm. Available for fire resistance classes F30 and F90, optionally in combination with airtightness, dust-proofness, and smoke-proofness. Installation at a later time is also easy due to the attachment fitting. The flush bonded Diamant board allows for flawless surfaces with minimal effort.

    F-TEC F30 / F-TEC F90 6

    Knauf alutop® Access Panel in the system with Knauf Free-Spanning Ceiling D131 Access Panel for Free-Spanning Ceiling D131 8

    Knauf alutop® Fire-Resistant Access Panel F-TEC F90 in the system with Knauf Free-Spanning Fireboard Ceiling K219 F-TEC F90 for Free-Spanning Fireboard Ceiling K219 9

    Fire–Resistance - cost-effectiveKnauf alutop® Access Panels FIRE PROTECTION CEILING, FIRE PROTECTION PARTITION, FIRE PROTECTION SHAFT WALL Particularly in large construction projects where requirements of cladding thickess, fire resistance, size, and installation loca-tions are fixed from the beginning, Knauf offers cost-effective so-lutions.

    FIRE PROTECTION CEILING 10

    FIRE PROTECTION PARTITION 11

    FIRE PROTECTION SHAFT WALL 12

    Knauf alutop® ACCESS DOOR for walls and jamb walls w/o fire resistance ACCESS DOOR 12

    The Knauf alutop® Access Panels AIRTIGHT and DUST-PROOF prevents penetration of air and dust in ceilings and walls without fire-resistance re-quirements with a cladding thickness of up to 25 mm, even with overpres-sure or low pressure.

    The Knauf alutop® Acess Panel DISINFECTANT-RESISTANT is special-ly designed for handling air-communicable diseases which are to be treated as per quarantine laws in infection quarantine stations in hospitals where the sealing of ventilation systems in ceilings or walls (without fire resistance re-quirements) must be guaranteed.

    AIRTIGHT and DUST-PROOF / DISINFECTANT-RESISTANT

    13

    Access Panels for Tiling 14

    Specifications 15

    Order Information, Construction 18

    Installation, Jointing, Surface treatment, Proofs 19

    Declarations of Compliance 20

    2

  • Ar-na-fett 12,6 mm

    Ar-na-fett 12 mmb b

    (Ar-na-light 11 mm

    Hinweis Auf Anfrage ist eine differenzierte Bemessung der Deckenunterkonstruktion möglich.

    Ar-na-fett 12 mm

    Ar-na-fett 12,6 mmAr-na-light 12 mm

    Ar-na-fett 12 mm Ar-na-light 12 mm

    *) Ar-na-light 11 mm

    *) Ar-na-light 11 mm

    Ar-na-light 11 mm

    Ar-na-light 11 mm

    Gerade Rundlochung 8/18 RDurchlaufende Lochungen

    Ar-na-light 11 mm

    Ar-na-fett 12 mm

    Ar-na-fett 12,6 mm

    c

    Frag

    en ?

    ?? F

    rage

    n ??

    ??

    Text Text TextText Text Text

    Text Text TextText Text Text

    Knauf alutop® Access PanelsProduct Overview

    REVO 12,5 REVO 18 Variant REVO 25 Variantfor 12.5 mm for 15 and 18 mm for 20 and 25 mm200 x 200 mm 200 x 200 mm 200 x 200 mm300 x 300 mm 300 x 300 mm 300 x 300 mm400 x 400 mm 400 x 400 mm 400 x 400 mm500 x 500 mm 500 x 500 mm 500 x 500 mm600 x 600 mm 600 x 600 mm 600 x 600 mm600 x 1200 mm 600 x 1200 mm 600 x 1200 mm700 x 700 mm 700 x 700 mm 700 x 700 mm800 x 800 mm 800 x 800 mm 800 x 800 mm900 x 900 mm 900 x 900 mm 900 x 900 mm1000 x 1000 mm 1000 x 1000 mm 1000 x 1000 mm1100 x 1100 mm 1100 x 1100 mm 1100 x 1100 mm1200 x 1200 mm 1200 x 1200 mm 1200 x 1200 mm≥ 1200 mm (multipart) ≥ 1200 mm (multipart) ≥ 1200 mm (multipart)Any intermediate size available

    F-TEC F30 F-TEC F90for 12.5 to 25 mm for 25 to 50 mm300 x 300 mm 300 x 300 mm400 x 400 mm 400 x 400 mm500 x 500 mm 500 x 500 mm600 x 600 mm 600 x 600 mm700 x 700 mm -800 x 800 mm -Intermediate sizes by request

    ● Standard equip-ment

    ◦ Optional— Not available

    REVO 12.5

    REVO 18 Variant

    REVO 25 Variant

    F-TEC F30

    F-TEC F90

    FIRE PROTECTIONF-TEC F90 for K219

    Access Panel for D131

    AIRTIGHT and DUST-PROOF

    DISINFEC-TANT-RESISTANT

    X-Ray radiation shielding

    CEILING PARTI-TION

    SHAFT WALL

    Face board flush bonded ● ● ● ● ● — — ● ● — ● ● ●

    Sealing ◦ ● ● ● ● ● ● ● ● — ● ● ●Intermediate sizes≥ 200 ≤ 600 mm ◦ ◦ ◦ ◦1) ◦1) ◦ ◦ ◦1) ◦1) ◦1) ◦1) — ◦1)Intermediate sizes > 600 ≤ 800 mm ◦ ◦ ◦ ◦ — ◦ ◦ ◦ — — ◦ — —Intermediate sizes > 800 ≤ 1200 mm ◦ ◦ ◦ — — — — — — — — — —Universally suitable for various cladding thicknesses

    — ● ● ● ● — — ● — — ● ● —

    Airtight and dust-proof — — — ◦ ◦ — — ◦ ◦ — ● ● —Smoke-proof — — — — ◦ — — ◦2) ◦ — — — —With factory-bonded perforated board ◦ — — — — — — — — — — — —Designed for on-site installation of perforated board

    ◦ — — — — — — — — — — — —Designed for on-site tiling ◦ ◦ ◦ ◦ ◦ — ◦ ◦ — — ◦ — ◦Four-square bolt or round cylinder lock ◦ ◦ ◦ ◦3) ◦3) ◦ ◦ ◦3) ◦3) — ◦3) — —Lock designed forprofile cylinder ◦ ◦ ◦ — — ◦ ◦ — — — — — —

    Standard access panels for ceilings, drywall partitions and furrings

    Fire-resistant access panels for ceilings, shaft walls and solid walls

    The Complete Program

    1) ≥ 300 mm 2) with F90 only 3) Four-square bolt not in combination with airtight, dust-proof, and smoke-proof options

    Five Types for Any Occasion

    3

  • Access Panel REVO 12.5

    Copyright by Knauf Gips KG N:\ATE\HOFMANN\Revisionsklappen\Aktuelle-Alle-Klappen Stand 01.08 Seite 4

    Examples - schematic drawingsInstallation in Knauf Ceiling Systems

    Installation in Knauf Partition/Furring Systems

    Size

    Opening dimension of cladding(= size + 2x 5 mm)

    Distance to the CD Channel 30 100

    5 5

    30 m

    m

    basic ceiling / installation

    REVO 18 Variant15 mm

    at least on two opposite sides 30 mm / 100 mm

    Distance to the

    Type 12.5 mm - with seal

    6

    30 100

    30 50

    Type 12.5 mm - with perforated board

    (= clearance)

    18 mm

    REVO 25 Variant20 mm 2x 12.5 / 25 mm

    Frame spacer or

    5

    30 100

    (= cl

    eara

    nce)

    Size

    Open

    ing

    dim

    ensio

    n of

    clad

    ding

    (= si

    ze +

    2x 5

    mm

    )5

    30 100

    if necessaryUW Profile as frame

    e.g. CW Stud

    Access Panel

    REVO 12.512.5 mm

    Installation of the ceiling, partition and furring systems

    Type 12.5 mm - without seal

    Type 12.5 mm - without seal

    Note

    spacer strip6

    Frame spacer orspacer strip

    2

    Size

    6Size

    Possible Cladding Thicknesses

    Size

    CD Channel

    Knauf Board

    according to Knauf Technical Data Sheets

    Exact size depends on perforation pattern

    REVO 12.5

    (frame)

    Access Panels REVOStandard Access Panels for Ceilings, Drywall Partitions and Furrings

    4

  • Examples - schematic drawings

    Seite 5

    Double metal grid (e.g. D112)

    a

    Trimming of the substructureDepending on type and installation situation of the access panels,trimmer profiles made of UW Profiles are necessary

    Stud spacing -a- continuous

    Flush metal grid (e.g. D113)

    Installation in Knauf Ceiling Systems Installation in Knauf Partition/Furring Systems

    Intermediate sizes

    Sizes

    200 x 200 300 x 300 400 x 400 500 x 500 600 x 600 600 x 1200 700 x 700 800 x 800 900 x 9001000 x 10001100 x 11001200 x 1200

    SealType "screwed" ( 625 mm)

    For on-site applic. of perforated boards ( 625 mm)Factory-bonded perforated boards ( 900 x 900 mm)

    For on-site tiling ( 600 x 800 mm)Prepared for surface quality Q4 (on-site)Four-square boltRound cylinder lockLock pre-designed for profile cylinder

    Additional options

    Multipart

    (= clearance)

    Claddingmm

    12.5

    1518

    202x 12,5 / 25

    Spac

    ing of

    carry

    ing ch

    anne

    ls

    Additional substructureIf supsended channels need to be cut and replaced by an additionalchannel, additional supensions are necessary

    Spacing of furring channels

    Spac

    ing of

    carry

    ing ch

    anne

    ls

    aa

    Stud spacing -a- with cut stud and trimmer profiles

    Spacing of furring channels

    aaa

    mm

    Standard equipment

    e.g. CW StudUW Profile

    e.g. CW Stud

    CD Channel

    REVO 12.5 REVO 18 VariantREVO 25 Variant

    REVO 12.5

    REVO 18 Variant

    REVO 25 Variant

    REVO

    REVO REVO

    REVO

    1)

    1) without seal ( 625 mm)

    Copyright by Knauf Gips KG N:\ATE\HOFMANN\Revisionsklappen\Aktuelle-Alle-Klappen Stand 01.08

    CD-Profil

    Access Panels REVOStandard Access Panels for Ceilings, Drywall Partitions, and Furrings

    5

  • Seite 6

    Examples - schematic drawingsInstallation in Knauf Ceiling Systems

    Installation in Knauf Shaft Wall Systems

    Ceiling and shaft wall systems with fire resistance

    F-TEC F30

    12.5 mm 15 mm

    18 mm 20 mm

    2x 12.5 / 25 mm

    Spacer strip

    F-TEC F90

    25 + 18 mm 2x 25 mm

    Opening dimension of cladding

    Access Panel F-TEC F30

    2x 20 mm

    Clearance(= size - 19 mm)

    (= size + 2x 55 mm)

    2x 12.5 / 25 mm

    Type F-TEC F30 (2x 12.5 mm)

    Type F-TEC F90

    Open

    ing

    dim

    ensio

    n of

    clad

    ding

    Clea

    ranc

    e(=

    Size

    - 19

    mm

    )

    (= si

    ze +

    2x 5

    5 m

    m)

    Access Panel

    UW Profile (trimmer)

    TypeF-TEC F90 (2x 20 mm)

    Note

    according to Knauf Technical Data Sheets

    70 m

    m

    basic ceiling / installationDistance to the

    Screw metal steel mountinglinks to CD Channel

    F30: 70 mmbasic wall / installationDistance to the

    Size

    Size

    Spacer strip Spacer strip

    Spacer strip

    CD- / CW- / UW Profile

    CD/CW/UW Profile Spacer strip

    Possible Cladding Thicknesses

    Spacer strip Spacer strip

    80 m

    m

    F90: 80 mm

    CD Channel

    Knauf Boards GKF

    CW Stud

    Copyright by Knauf Gips KG N:\ATE\HOFMANN\Revisionsklappen\Aktuelle-Alle-Klappen Stand 01.08

    F-TEC F90

    (frame)

    Also suitable for solid walls

    Access Panels F-TEC F30 / F-TEC F90Fire-Resistant Access Panels for Ceilings, Shaft Walls and Solid Walls

    6

  • Examples - schematic drawings

    Seite 7

    Double metal grid (e.g. D112)

    a

    Trimming of the substructureDepending on type and installation situation of the access panels,trimmer profiles or frames made of profiles are necessary

    Stud spacing -a- continuous studs

    Flush metal grid (e.g. D113)

    Installation in Knauf Ceiling Systems Installation in Knauf Shaft Wall Systems

    Intermediate sizes

    Sizes

    300 x 300400 x 400500 x 500600 x 600700 x 700800 x 800

    Airtight and dust-proof ( 600 x 600 mm)

    Four-square boltRound cylinder lock

    Additional options

    Fireboard face

    mmCladdingmm

    12.5

    Spac

    ing of

    carry

    ing ch

    anne

    ls

    Additional substructure

    If supsended channels need to be cut and replaced by additionalchannels, additional supensions are necessary

    Spacing of furring channels

    Spac

    ing of

    carry

    ing ch

    anne

    ls

    aa

    Stud spacing -a- with cut stud and trimmer profiles

    Spacing of furring channels

    aaa

    1518202x 12.5 / 25

    2x 2025 + 182x 25

    Smoke-proof ( 600 x 600 mm)

    (Size - 19 mm = clearance)

    On request

    Alternative suspension locations4 additional suspensions

    CW Stud

    UW Profile

    CW Stud

    UW Profile

    F-TEC F30 F-TEC F90

    F-TEC F30

    F-TEC F90

    F-TEC F30 F-TEC F90

    F-TEC

    F-TECF-TEC

    F-TEC F-TEC

    If the installation of the access panel is performed at a later time,the cladding is sawed out. Apply frame made of circumferential profilepieces (UW or CW) and screw attach (spacing of screws 150 mm).

    Subsequent installation in finished shaft walls is possible

    CW Stud

    Copyright by Knauf Gips KG N:\ATE\HOFMANN\Revisionsklappen\Aktuelle-Alle-Klappen Stand 01.08

    2x 12.5 / 25

    For on-site tiling

    CD Channel

    CD Channel

    Access Panels F-TEC F30 / F-TEC F90Fire-Resistant Access Panels for Ceilings, Shaft Walls and Solid Walls

    7

  • Access Panel

    UW Profile

    6 6Size (450 mm)

    CW Profile

    Seite 8

    Schematic drawings

    Sizes

    450 x 450mm

    Claddingmm

    18 mm

    Solely from below and from aboveF30

    450 x 600450 x 1500

    Notes

    Type A + Type B

    Circumferential board strips GKF

    Opening dimension of cladding(= size + 2x 6 mm)

    (= clearance)

    (= clearance)

    Longitudinal sections

    CW double profileas bearing profile

    5

    5

    Construction of free-spanning ceiling acc. to Knauf Technical Data Sheet D131 (consider fire

    Lateral sections

    for D131

    protection requirements).With free-spanning ceilings without fire resistance or with fire resistance from

    Access panel can be fully dismounted.

    Opening dimension of cladding(= size + 2x 6 mm)

    Diagram:

    Type A Type B

    LayoutsSpacing of furring channels 625 mm Spacing of furring channels 625 mm

    below: Installation of access panel according to Type A.

    Lateral section

    Long

    itudin

    al se

    ction

    CW double profilewith covering strip

    CW double profilewith covering strip

    Circumferential board strips GKF

    Slide UW Profile ontodouble profile

    CW Profile

    Lateral section

    Long

    itudin

    al se

    ction

    Intermediate sizes available on request (max. 450 x 1500 mm)

    for D131Access Panel

    for D131Access Panel

    Knauf Board GKF

    Copyright by Knauf Gips KG N:\ATE\HOFMANN\Revisionsklappen\Aktuelle-Alle-Klappen Stand 01.08

    Diagram is not showing upper covering

    Knauf Board GKF, applied loose

    Circumferential board strips GKFKnauf Board GKF, applied loose

    Access Panel for Free-Spanning Ceiling D131Fire Resistance Class F30

    8

  • Seite 9

    Schematic drawings

    Slide UW Profile onto double profileand connect

    Solely from below Solely from below and from aboveF90F90

    Lateral sections

    Opening dimension of cladding

    Clearance(= size - 19 mm)

    (= size + 2x 96 mm)

    Size (439 mm)

    Access Panel F-TEC

    Mineral wool as from ceiling

    Size

    439 x 619mm

    Claddingmm

    (Size - 19 mm

    2x 20 mm20 mm

    NoteConstruction of free-spanning ceiling acc. to

    Fireboard, applied looseca. 100 mm

    Opening dimension of cladding(= size + 2x 56 mm)

    Longitudinal sections

    Screw metal steel mounting links to UW Profile

    12.5 mm Fireboardcircumferential strips

    UW Profile

    CW double profileas bearing profile

    UW Profile

    Spacing of furring channels 625 mm Spacing of furring channels 625 mmLayouts

    for K219

    Long

    itudin

    al se

    ction

    Long

    itudin

    al se

    ction

    Lateral sectionBend UW at cornerand slide ontodouble profile12.5 mm Fireboardstrips - circumferential(apply after installation of access panel)

    Bend UW at cornerand connect withdouble profile

    CW double profilewith covering strips

    Lateral section

    CW double profile

    Access Panel F-TECfor K219

    Access Panel F-TECfor K219

    = clearance)

    Fireboard

    12.5 mm Fireboardcircumferential strips

    UW Profile

    Copyright by Knauf Gips KG N:\ATE\HOFMANN\Revisionsklappen\Aktuelle-Alle-Klappen Stand 01.08

    (20 + 20 mm)

    Fireboard, applied loose

    Intermediate sizes

    Smoke-proof

    Additional options

    Airtight and dust-proof Knauf Technical Data Sheet K219 (consider fire

    Four-square boltRound cylinder lock

    Diagram is not showing upper covering

    protection requirements)

    Access Panel F-TEC for Free-Spanning Fireboard Ceiling K219Fire Resistance Class F90

    9

  • Seite 10

    Examples - schematic drawings

    Double metal grid (e.g. D112) Flush metal grid (e.g. D113)

    Spac

    ing of

    carry

    ing ch

    anne

    ls

    Additional substructure

    If supsended channels need to be cut and replaced by

    Spacing of furring channels

    Spac

    ing of

    carry

    ing ch

    anne

    ls

    Spacing of furring channels

    Size(= cleareance)

    6

    Opening dimension of cladding(= size + 2x 6 mm)

    26

    Screw metal steel mounting links Aditional suspenderto circumferential CW Profile Nonius Suspension

    Type F30 (2x 12.5 mm)

    Intermediate sizes

    Four-square boltRound cylinder lock

    Multipart

    Lock pre-designed for profile cylinder

    Note

    Sizes

    300 x 300mm

    400 x 400500 x 500600 x 600

    Cladding

    12.52x 12.5 / 25

    mmAdditional options

    (= clearance)

    2x 20

    Installation in Knauf Ceiling Systems

    CD Channel

    100 m

    m

    basic ceiling / installationsDistance to the

    Fireboard face

    Alternative suspension locations4 additional suspensions

    Access Panel

    Fire-resistant ceiling constructions according to Knauf Technical Data Sheets

    Mineral wool panel

    CD Profile

    F30 F90 F30 F90

    Access Panel Access PanelFIRE FIRE

    CEILING CEILING

    Knauf Boards GKF

    Copyright by Knauf Gips KG N:\ATE\HOFMANN\Revisionsklappen\Aktuelle-Alle-Klappen Stand 01.08

    1) max. size for F30: 800 x 800 mm; for F90: 600 x 600 mm

    1)

    FIRE PROTECTION CEILING

    CD Profile

    (included in scope of delivery)

    additional channels, additional supensions are necessary.

    PROTECTION PROTECTION

    Access Panel FIRE PROTECTION CEILINGFire Resistance Class F30 / F90

    10

  • Examples - schematic drawings

    Seite 11

    Sizes

    300 x 300mm

    400 x 400500 x 500600 x 600

    Cladding

    12.52x 12.5 / 25

    mm

    Intermediate sizes

    Four-square boltRound cylinder lock

    Additional options

    Lock pre-designed for profile cylinder

    a

    Trimming of the substructureDepending on type and installation situation of the access panels,trimmer profiles made of UW Profiles are necessary

    aa

    Stud spacing -a- with cut stud and trimmer profiles

    aaa

    Stud spacing -a- continuous stud

    Type F90 (2x 12.5 mm)

    Installation in Knauf Partition Systems6

    30 100

    6

    UW Profile as trimmer

    e.g. CW Stud

    FIRE PROTECTIONAccess Panel

    Fire-resistant partition constructions according to Knauf Technical Data Sheets

    Note

    (= cl

    eara

    nce)

    Size

    Open

    ing

    dim

    ensio

    n of

    clad

    ding

    (= si

    ze +

    2x 6

    mm

    )

    e.g. CW StudUW Profile

    e.g. CW StudUW Profile

    F30 F90 F30 F90

    PARTITION

    PARTITION

    Access Panel

    Access PanelFIRE

    FIRE

    (= clearance)

    Knauf Boards GKF

    Copyright by Knauf Gips KG N:\ATE\HOFMANN\Revisionsklappen\Aktuelle-Alle-Klappen Stand 01.08

    1)

    1) Max. tested size 510 x 810 mm

    30 100

    For on-site tiling

    PROTECTION

    PARTITION

    PROTECTION

    Access Panel FIRE PROTECTION PARTITIONFire Resistance Class F30 / F90

    11

  • Examples - schematic drawings

    Seite 12

    Sizes

    464 x 464mm

    464 x 964964 x 464

    Cladding

    2x 12.52x 20

    mm

    Intermediate sizes

    Four-square boltRound cylinder lock

    Additional options

    Installation in Knauf Installation Shaft Walls Systems F30 / F90

    25 + 182x 25

    UW Profile as trimmerCW Profile(frame / stud)

    ACCESS DOOR Installation in Knauf Partition or Furring Systems / Jamb Walls

    Fireboard faceAirtight and dust-proofSmoke-proof

    Sizes

    300 x 300mm

    400 x 600464 x 964

    Claddingmm

    Intermediate sizes

    Round cylinder lock

    Additional options

    12,52x 12.5 / 25

    Opening dimension of cladding

    Clearance(= size - 19 mm)

    (= size + 2x 82 mm)

    Size

    FIRE PROTECTION

    Type F90 (2x 25 mm)

    Type 2x 12.5 mm

    Access Panel

    Circumferential profiles are required

    Opening dimension of cladding

    Clearance(= size - 19 mm)

    (= size + 2x 55 mm)

    Size

    Horizontal section

    Horizontal section

    Access Panel for Shaft Walls

    F30 F90

    F30 F90

    e.g. CW Profile(frame / stud)

    ACCESS DOOR

    UW Profile as trimmer

    (Size - 19 mm= clearance)

    (Size - 19 mm= clearance)

    Knauf Boards GKF

    Knauf Boards

    Circumferential profiles are required

    Construction of shaft wall, partition or furring systems according to Knauf Technical Data Sheets.

    Note

    With side hinge usable for left-hinged or right-hinged door

    Copyright by Knauf Gips KG N:\ATE\HOFMANN\Revisionsklappen\Aktuelle-Alle-Klappen Stand 01.08

    1)

    1) Max. size 464 x 964 mm / 964 x 464 mm

    (F60)

    Also applicable for solid walls

    For on-site tiling

    Four-square bolt

    Lock pre-designed for profile cylinder

    SHAFT WALL

    Access Panel FIRE PROTECTION SHAFT WALL / ACCESS DOORAccess Panels for Shaft Walls Fire Resistance Class F30 / F90, Access Door for Walls and Jamb Walls

    12

  • Examples - schematic drawings

    Seite 13

    Airtight and Dust-Proof Installation in Knauf Ceiling, Partition and Furring Systems

    DISINFECTANT-RESISTANT, airtight and dust-proof

    Sizes

    300 x 300mm

    400 x 400500 x 500

    Claddingmm

    Intermediate sizes

    Round cylinder lock

    Additional options

    12.52x 12.5 / 25

    600 x 600

    Sizes

    400 x 400mm

    600 x 600

    Claddingmm

    Intermediate sizesLock

    Additional options

    12.52x 12.5 / 25

    Not availableNot available

    Type 2x 12.5 mm

    Opening dimension of cladding

    Clearance(= size - 19 mm)

    (= size + 2x 55 mm)

    Size

    Opening dimension of cladding

    Size(= clearance)

    (= size + 2x 65 mm)

    Type 2x 12.5 mm

    50 m

    m 50

    mm

    Vertical section ceiling

    CD Channel (frame)

    CD Channel (frame)

    AIRTIGHT and DUST-PROOFAccess Panel

    DISINFECTANT-RESISTANTAccess Panel

    (Size - 19 mm= clearance)

    (= clearance)

    Vertical section ceiling

    Knauf Boards

    Knauf Boards

    Circumferential profiles are required

    Circumferential profiles are required.

    Construction of ceiling, partition or furring systems according to Knauf Technical Data Sheets.

    Note

    Copyright by Knauf Gips KG N:\ATE\HOFMANN\Revisionsklappen\Aktuelle-Alle-Klappen Stand 01.08

    Tested for airtightness up to 750 pascal, over-pressure or low pressure

    For on-site tiling

    Installation in Knauf Ceiling, Partition and Furring Systems

    In case of installation in ceilings additional suspenders are required in the corners.

    In case of installation in ceilings additional suspenders are required in the corners.

    AIRTIGHT and DUST-PROOF / DISINFECTANT-RESISTANTWithout Fire Resistance for Ceilings, Drywall Partitions and Furrings

    13

  • Copyright by Knauf Gips KG N:\ATE\HOFMANN\Revisionsklappen\Aktuelle-Alle-Klappen Stand 01.08 Seite 14

    Example: REVO - schematic drawings

    ViewNotes

    The access panel is configured based on the tile pattern. Information on the dimensionsof the tiles (W x H), width of joints and adhesive thickness are required.

    Laying of tile in thin-bed application only

    Exact size depends on format of tiles.

    Size(= clearance)

    Size

    (= cl

    eara

    nce)

    Fire resistance is optional

    = width of tiling joint= tile format FUFL

    Sections

    FLFU

    FUFU

    FL

    Size

    (= cl

    eara

    nce)

    Insert seal(included in scope of delivery)

    FL FUFU FUFL

    Size(= clearance)

    Horizontal section

    Vertical section

    Construction of ceiling, partition, shaft wall or furring systems according to

    TileW x H

    Fill outer frame after installation of access panel and apply tiles exactly along the outer frame.

    Tile adhesiveTile

    Knauf Technical Data Sheets.

    Knauf alutop® Access PanelsFor Tiling

    14

  • Knauf alutop® Access PanelsSpecifications

    Item Description No. of units Unit price Total price

    ......Standard access panel for ceiling / wall *, cladding thickness 12.5 mmDeliver and install access panel for suspended ceiling/non-load bearing, room-enclosing drywall partition/ independent furring *, configured for installation in 12.5 mm thick clad constructions, as standard configuration,with flush bonded/ screwed * Knauf Diamant hard gypsum board (GKFI) 12.5 mm/ perforated board face *, size (clearance): .......… x .......… mm,securing of the hatch using self-adjusting clasping springs, with a lock- and hinge mechanism that is integrated in the frame corners and concealed. Equipped with round cylinder lock / four-square bolt / lock, designed for profile cylinders *,*.Product / system: Knauf alutop® Standard Access Panel REVO 12.5 ......... pcs .......... € .......... €

    ......Standard access panel for ceiling / wall *, cladding thickness 15/ 18 * mmDeliver and install access panel for suspended ceiling/ non-load bearing, room-enclosing drywall partition/ independent furring *,configured for installation in 15/ 18 * mm thick clad constructions,as standard configuration, with flush bonded Knauf Diamant hard gypsum board (GKFI) 12.5 mm, size (clearance): .......… x .......… mm,securing of the hatch using self-adjusting clasping springs, with a lock- and hinge mechanism that is integrated in the frame corners and concealed.Equipped with round cylinder lock / four-square bolt / lock, designed for profile cylinders *.* Product / system: Knauf alutop® Standard Access Panel REVO 18 Variant ......... pcs .......... € .......... €

    ......Standard access panel for ceiling / wall *, cladding thickness 20/ 25 * mmDeliver and install access panel for suspended ceiling/ non-load bearing, room-enclosing drywall partition/ independent furring *,configured for installation in 20/ 25 * mm clad constructions,as standard configuration, with flush bonded Knauf Diamant hard gypsum board (GKFI) 12.5 mm, size (clearance): .......… x .......… mm,securing of the hatch using self-adjusting clasping springs, with a lock- and hinge mechanism that is integrated in the frame corners and concealed.Equipped with round cylinder lock / four-square bolt / lock, designed for profile cylinders *.* Product / system: Knauf alutop® Standard Access Panel REVO 25 Variant ......... pcs .......... € .......... €

    ......Fire–resistant access panel F30 for ceiling/ shaft wall/ solid wall *Deliver and install access panel for suspended ceiling/ shaft wall *,configured for installation in 12.5/ 15/ 18/ 20/ 25 * mm clad constructions/ solid wall *,as fire-resistant configuration, fire resistance class DIN 4102-2: F30,with flush bonded Knauf Diamant hard gypsum board (GKFI)/ Fireboard A1 *, size (clearance + 19 mm): .......… x .......… mm, securing of the hatch using self-adjusting clasping springs, with a concealed lock- and hinge mechanism.Airtight and dust-proof (class 4 to 5) acc. to DIN EN 1026 + DIN EN 12211,* Equipped with round cylinder lock / four-square bolt *.*Product / system: Knauf alutop® Fire-Resistant Access Panel F-TEC F30 ......... pcs .......... € .......... €

    ......Fire–resistant access panel F90 for ceiling/ shaft wall/ solid wall *Deliver and install access panel for suspended ceiling/ shaft wall *,configured for installation in 25/ 30/ 40/ 43/ 50 * mm clad constructions/ solid wall *,as fire-resistant configuration, fire resistance class DIN 4102-2: F90,with flush bonded Knauf Diamant hard gypsum board (GKFI)/ Fireboard A1 *, size (clearance + 19 mm): .......… x .......… mm, securing of the hatch using self-adjusting clasping springs, with a concealed lock- and hinge mechanism.Airtight and dust-proof (class 4 to 5) acc. to DIN EN 1026 + DIN EN 12211/ smoke proof following DIN 18095-2 *,* Equipped with round cylinder lock / four-square bolt *.*Product / system: Knauf alutop® Fire-Resistant Access Panel F-TEC F90 .......... pcs .......... € .......... €

    * Cancel not applicable items Sub-total ............... € 15

  • Knauf alutop® Access PanelsSpecifications

    Item Description No. of units Unit price Total price

    ......Access panel/ Fire-resistant access panel F30 * for Knauf Free-Spanning Ceiling D131Deliver and install access panel for free-spanning ceiling, configured for installation in 18 mm clad constructions,as fire-resistant configuration, fire resistance class DIN 4102-2: F30,*free-spanning ceiling construction type A/ B *,*with flush screwed Knauf GKF, size (clearance): .......… x .......… mm, hatch configured for inlay mounting.Product/ system: Knauf alutop® Access Panel// Fire-Resistant Access Panel F30 * for D131 ......... pcs .......... € .......... €

    ......Fire-resistant access panel F90 for Knauf Free-Spanning Fireboard Ceiling K219Deliver and install access panel for free-spanning ceiling,configured for installation in 20/ 2x20 * mm clad constructions,as fire-resistant configuration, fire resistance class DIN 4102-2: F90,with flush bonded Knauf Fireboard A1, size (clearance + 19 mm): .......… x .......… mm, securing of the hatch using self-adjusting clasping springs, with a concealed lock- and hinge mechanism.Airtight and dust-proof (class 4 to 5) acc. to DIN EN 1026 + DIN EN 12211/ smoke proof following DIN 18095-2 *,*Equipped with round cylinder lock / four-square bolt *.*Product/ system: Knauf alutop® Fire-Resistant Access Panel F-TEC F90 for Free-Spanning Fireboard Ceiling K219 ......... pcs .......... € .......... €

    ......Fire-resistant access panel F30/ F90 * for ceilingDeliver and install access panel for suspended ceiling,configured for installation in 12.5/ 25/ 40 * mm clad constructions,as fire-resistant configuration, fire resistance class DIN 4102-2: F30/ F90 *,with flush bonded Knauf GKF/ Fireboard A1 *, size (clearance): .......… x .......… mm, securing of the hatch using self-adjusting clasping springs, with a concealed lock- and hinge mechanism.Equipped with round cylinder lock / four-square bolt/ lock, designed for profile cylinders *,* multipart.*Product/ system: Knauf alutop® Access Panel FIRE PROTECTION CEILING“ F30/ F90 * ......... pcs .......... € .......... €

    ......Fire-resistant access panel F30/ F90 * for drywall partitionDeliver and install access panel for non-load bearing, room-enclosing drywall partition configured for installation in 12.5/ 25 * mm clad constructions,as fire-resistant configuration, fire resistance class DIN 4102-2: F30/ F90 *,with flush screwed Knauf GKF/ Fireboard A1 *, size (clearance): .......… x .......… mm, securing of the hatch using self-adjusting clasping springs, with a concealed lock- and hinge mechanism.Equipped with round cylinder lock / four-square bolt/ lock, designed for profile cylinders *.*Product/ system: Knauf alutop® Access Panel FIRE PROTECTION PARTITION“ F30/ F90 * ......... pcs .......... € .......... €

    ......Fire-resistant access panel F30 for shaft wall/ solid wallDeliver and install access panel for shaft wall,configured for installation in 25 mm clad constructions/ solid wall *,as fire-resistant configuration, fire resistance class DIN 4102-2: F30,with flush bonded Knauf Diamant hard gypsum board (GKFI)/ Fireboard A1 *, size (clearance + 19 mm): .......… x .......… mm, securing of the hatch using self-adjusting clasping springs, with a concealed lock- and hinge mechanism.Airtight and dust-proof (class 4 to 5) Acc. to DIN EN 1026 + DIN EN 12211,* Equipped with round cylinder lock / four-square bolt *.*Product/ system: Knauf alutop® Access Panel FIRE PROTECTION SHAFT WALL F30 .......... pcs .......... € .......... €

    * Cancel not applicable items Sub-total ............... €16

  • Knauf alutop® Access PanelsSpecifications

    Item Description No. of units Unit price Total price

    ......Fire-resistant access panel F60/ F90 * for shaft wall/ solid wallDeliver and install access panel for shaft wall,configured for installation in 30/ 40/ 43/ 50 * mm clad constructions/ solid wall *,as fire-resistant configuration, fire resistance class DIN 4102-2: F60/ F90 *,with flush bonded Knauf Diamant hard gypsum board (GKFI)/ Fireboard A1 *, size (clearance+19 mm): .......… x .......… mm, securing of the hatch using self-adjusting clasping springs, with a concealed lock- and hinge mechanism.Airtight and dust-proof (class 4 to 5) Acc. to DIN EN 1026 + DIN EN 12211/ smoke proof following DIN 18095-2 *,*Equipped with round cylinder lock / four-square bolt *.*Product/ system: Knauf alutop® Access Panel FIRE PROTECTION SHAFT WALL F60/ F90 * ......... pcs .......... € .......... €

    ......Airtight and dust-proof access panel for ceiling/ wall *, cladding thickness 12.5/ 25 * mmDeliver and install access panel for suspended ceiling/ non-load bearing, room-enclosing drywall partition/ furring *,configured for installation in 12.5/ 25 * mm clad constructions, as airtight and dust-proof configuration (class 4 to 5) DIN EN 1026 + DIN EN 12211, *, with flush bonded Knauf Diamant hard gypsum board (GKFI), size (clearance + 19 mm): .......… x .......… mm, securing of the hatch using self-adjusting clasping springs, with a concealed lock- and hinge mechanism.Equipped with round cylinder lock.* Product/ system: Knauf alutop® Access Panel AIRTIGHT and DUST-PROOF ......... pcs .......... € .......... €

    ......

    Disinfectant-resistant access panel for ceiling / wall *, cladding thickness 12.5/ 25 * mmand install access panel for suspended ceiling/non-load-bearing, room-enclosing drywall partition/ independent furring *,configured for installation in 12.5/ 25 * mm clad constructions,as disinfectant-resistant configuration (acc. to TRGS 522), with bonded plastic panel and anodized aluminium face plate, size (clearance): 400 x 400 / 600 x 600 * mm, securing of the hatch using self-adjusting clasping springs, with a concealed lock- and hinge mechanism.Product/ system: Knauf alutop® Access Panel DISINFECTANT-RESISTANT ......... pcs .......... € .......... €

    ...... Cutout section as upgrade for ceiling/drywall partition/ shaft wall *,rectangular, dimensions in mm................ . ......... pcs .......... € .......... €

    ...... Reinforce substructure at opening,CD Profile/ CW Profile/ UW Profile * DIN 18182-1, metal gauge 0.6 mm,as upgrade for ceiling lining/ceiling/drywall partition/shaft wall *,rectangular, dimensions in mm................ . ......... pcs .......... € .......... €

    ...... Upgrade for specified access panel, for round design,Securing chain for hatch, clearance dimension Ø 250 mm/ 400 mm/ in mm ............ *. ......... pcs .......... € .......... €

    ...... Upgrade for specified access panel,configuration with face panel made of perforated boards/ slotted boards *,Perforation/ slotting * pattern................................... . ......... pcs .......... € .......... €

    ...... Upgrade for specified access panel, bent for concave/ convex * design,Radius in mm ..................... . ......... pcs .......... € .......... €

    ...... Upgrade for specified access panel,for design and layout as trapezoid/ segmental arch *,Dimensions in mm ..................... . ......... pcs .......... € .......... €

    ...... Subsequent filling of access panel joint. .......... pcs .......... € .......... €

    * Cancel not applicable items Sub-total ............... € 17

  • Knauf alutop® Access PanelsOrder Information, Construction

    ConstructionSelect access panels considering cladding thick-ness of the Knauf systems.Knauf alutop® panels consist of a firm outer alu-minum frame, and an openable and fully detach-able hatch. REVO and F-TEC are equipped with flush bonded or screwed face board made of Knauf Diamant or Fireboard A1, applied either at the factory or on-site. Outer frame and hatch of the access panels are reinforced on the rear side using corner connectors. The hatch is fixed flush with the outer frame using special Knauf alutop® locks and hinge brackets. A joint width of only ap-prox. 1.5 mm is visible between the outer frame and the hatch when fully mounted. With rectangular ceiling access panels, the lock and hinge system is always mounted on the long side.

    REVOStandard access panels for installation in ceil-ings, drywall partitions and furrings without spe-cific building physical requirements. ■ REVO 12.5 for 12.5 mm cladding thickness■ REVO 18 Variant for 15 and 18 mm cladding

    thickness■ REVO 25 Variant for 20 and 25 mm cladding

    thickness Installation with trimmer profiles, if necessary. Suitable for subsequent installation in finished walls/ceilings.Use of round cylinder or profile cylinder locks and four-square bolting is also optional.

    F-TECFire-resistant access panels for universal instal-lation in ceilings, shaft walls (single-side clad dry-wall partitions) and solid walls (DIN 4102-4) with fire protection requirements for fire resistance classes F30 and F90, for all common cladding thicknesses in Knauf Systems. Installation with additional substrucure/trimmer profiles/frames. Fire-resistant F-TEC access panels can also, op-tionally, be designed in combination with airtight, dust-proof and smoke-proof options. Suitable for subsequent installation in finished walls/ceil-ings. Installation of round cylinder locks and four-square bolt is also optional.

    Free-Spanning Ceilings D131/K219System D131: Free-Spanning Ceilings: ■ Without fire resistance: Access panel as inlay

    mounting■ Fire resistance class F30, ceiling construction Type A: Access panel as inlay mounting with

    fixed fire protection insulation; apply insulation layer lying on top of the ceiling along circumfer-ence of access panel outer frame.

    ■ Fire protection class F30, ceiling construction Type B: Access panel as inlay mounting with fixed fire protection insulation, additonal instal-lation of circumferential board strips fastened on CW/UW Profile frame

    System K219: Free-Spanning Fireboard Ceilings F90: Access panels with fixed fire protection in-sulation, installation with circumferential UW Pro-file frame; with fire protection, in case of fire resis-tance from above with circumferential Fireboard strips; also position upper covering of free-span-ning ceiling across the opening of the access panel. Optionally, with airtight and dust-proof or smoke-proof option as well as round cylinder lock and four-square bolt.

    FIRE PROTECTION CEILINGFire-resistant access panel for ceilings with fire protection requirements F30 and F90 for cladding thicknesses 12.5, 25, and 40 mm. Installation with additional metal grid/trimmer profiles. Op-tionally, fire-resistant access panels with round cylinder locks, locks designed for profile cylinders or equipped with four-square bolt. A multipart de-sign of the hatch is also permissible.

    FIRE PROTECTION PARTITIONFire-resistant access panels for drywall partitions with fire protection requirements F30 and F90, for cladding thicknesses 12.5 and 25 mm. Installa-tion with additional metal frame/trimmer profiles. Optionally, fire-resistant access panels with round cylinder locks, locks designed for profile cylinders or equipped with four-square bolt.

    FIRE PROTECTION SHAFT WALLFire-resistant access panels for shaft walls (dry-wall partitions with single-side cladding) with fire protection requirements F30, F60, and F90, for cladding thicknesses 2x12.5 mm (F30), 18+25 mm (F60), 2x20, and 2x25 mm (F90). Installation with additional metal frame/trimmer profiles. Op-tionally, with airtightness and dust-proofness or smoke-proofness (F90 only) as well as round cyl-inder lock or four-square bolt.

    ACCESS DOORUsable for left-hinged or right-hinged installation, for cladding thickness up to 25 mm. Installation with additional metal frame/trimmer profiles.

    AIRTIGHT and DUST-PROOFAccess panels for universal installation in ceil-ings, drywall partitions and furrings. Airtight and dust-proof according to DIN EN 1026 and DIN EN 12211 (for combination with fire resistance, see F-TEC or FIRE PROTECTION SHAFT WALL) for all common cladding thicknesses in Knauf Sys-tems. Installation with additional metal frame/grid//trimmer profiles.

    DISINFECTANT-RESISTANTAccess panels for universal installation in cei-lings, walls, and furrings. Disinfectant resistancefollowing TRGS 522, for cladding thicknesses 12.5 / 2x12.5 and 25 mm. Seals are to be re-placed after one year maximum, after max. 15 gassing procedures, or after reaching a specified level of leakage. Installation with additional metal frame/grid/trimmer profiles.

    Order InformationRequired specifications for ordering: ■ Size of the installed access panel■ Mounting component (e. g, ceiling, shaft wall...)■ Cladding thickness■ Type of cladding ■ Fire resistance class, if necessary

    Special details/additional options■ Access panels for tiling: Specify tile dimensions, joint width, adhesive

    thickness, tile thickness and cladding thick-ness;

    The exact clearance is determined through the tile format.

    ■ Access panels for perforated board ceilings: Specify perforation pattern and the color of

    the fleece. The exact clearance is determined through the perforation pattern.

    Either on-site application of perforated board or perforated board is bonded at the factory.

    ■ Special configurations (e.g., access panels with lead sheet lamination, splash water proof etc.) on request

    ■ Airtight and dust-proof■ Smoke-proof■ Designed for on-site applied surface quality Q4

    on request■ Multipart configuration ■ Round cylinder lock, lock designed for profile

    cylinder or four-square bolt

    18

  • Knauf alutop® Access PanelsInstallation, Jointing, Surface Treatment, Proofs

    ProofsFire resistance (ABP)■ Suspended ceilings: P 3400/4965 (F30/F90 solely) P-3935/4719 (F30/F90 with basic ceiling)■ Free-Spanning Ceiling K219: P-3085/3824 (F90 from below and from above) P-3935/4719 (F90 from below)■ Free-Spanning Ceiling D131: P-3964/2172 (F30)

    ■Drywall partitions W11: P-3310/563/07 (F30/F90)■ Installation shaft walls: W628: P-3077/0679 (F30) P-3078/0689 (F90) W629: P-3079/0699 (F30/F90) W630: P-3969/2222 (F30/F90)■ Solid walls: P-3295/2366

    Disinfectant resistanceTÜV report BB-NEG2-LEI/RiF Nr. 552397/001

    Airthigtness and dust-proofness acc. to DIN EN 1026:200-09 + DIN EN 12211:2000-12Test report 104 24358

    Smoke proofness following DIN EN 18095-2:1991-03Test report 281 24570

    Surface TreatmentSurface treatment of the access panels with gyp-sum board face following Knauf Technical Data Sheet for the respective system. For tile covering observe instructions on page 14.

    Note to the painterGenerally remove the access panel hatch before coating and paint separately so that no paint pen-etrates the narrow joint between the hatch and the outer frame. Thoroughly clean outer frame, hatch, and particularly the seal.

    InstallationGeneralInstallation of access panels as per accompany-ing application instructions, installation of Knauf Systems in accordance with relevant current Knauf Technical Data Sheets. Cladding screwed to frame using Drywall Screws TB or TN (see de-tail pages). CAUTION: Length of screw deter-mined by cladding. Minimum 3 pieces per frame side. Distance between screws maximum 150 mm. Predrilling only necessary with access pan-els FIRE PROTECTION CEILING. No board joints of the cladding are allowed near the ac-cess panel.With wall access panels, a clearance of ≥ 40 mm (DISINFECTANT-RESISTANT: 50 mm) must be ensured in the upper third of the rear side of the hatch for opening the panel.

    REVO and FIRE PROTECTION PARTITIONCut out opening 12 mm (with REVO 12.5 without seal 10 mm) larger than the access panel size (= clearance).If necessary, install additional trimmer profiles made of CD- or CW profiles based on the dimen-sions of the access panel, maintain distances be-tween the cutout section and CD- or UW profiles of 30 mm minimum and 100 mm maximum (with walls for the trimmer profiles, with ceilings on at least two opposite sides). Additional suspenders are required for replacing suspended ceiling pro-files.Place the outer frame of the access panel in the opening, lay it on the cladding, align and screw

    attach. Subsequently insert hatch and check lock for proper functioning. If the distance to the in-stallations in the wall or ceiling is less than 200 mm, it is necessary to perform the installation of the the outer frame in the gypsum board before the cladding.

    Access Panel for D131Cut out opening 12 mm larger than the access panel size (= clearance). Place access panel in the opening, lay it on the cladding, align and screw attach. For an installation with fire protec-tion and ceiling construction Type B, install the CW/UW Profile frame based on the size of the access panel and attach circumferential board strips GKF to CW/UW Profile frame. Subsequent-ly insert hatch.

    Fire-Resistant Access Panel for K219The application is performed while installing the metal grid or at a later time. Make cutout section 5 mm larger than the gypsum frame of the ac-cess panel. Install UW Profile frame based on the size of the access panel. Fasten Fireboard strips along circumference of UW profile frame. Put gypsum board frame of the access panel on the profile frame, align and screw attach. Screw met-al sheet mounting links to UW profile frame. Sub-sequently insert hatch and check lock for prop-er functioning.

    FIRE PROTECTION CEILINGCut out opening 12 mm larger than the access panel size (= clearance). Install trimmer profile frame made of CD Profiles based on the size of the access panel. The Universal or Flush Con-nectors (4 pcs.) which are required are included as part of the delivery scope. In addition, fasten 4 suspenders in the corner areas of the access panel. Insert outer frame of the access panel in the opening, place on the cladding, install mount-ing brackets, align and screw attach. ubsequently apply mineral wool board (incl. in scope of deliv-ery), insert hatch and check lock for proper func-tioning.

    Access panels F-TEC, FIRE PROTECTION SHAFT WALL, AIRTIGHT and DUST-PROOF, and DISINFECTANT-RESISTANTApplication can either be performed while instal-ling the metal grid or at a later time. Cut out ope-ning 5 mm larger than the gypsum frame of the access panel. Install trimmer profile frame made of CD or CW/UW Profiles according to the size of the access panel In case of installation in ceilings, also attach 4 additional suspenders in the corner areas of the access panel. Lay gypsum board fra-mes of the access panel on the trimmer profiles, align and screw attach. With F- TEC F90 in cei-ling, screw metal sheet mounting links to CD Pro-file trimmer frame. Subsequently insert hatch and check lock for proper functioning.

    JointingFill outer frame of access panel and the ceiling-/wall surface with Uniflott or Fireboard Filler.Recommended: With access panels F-TEC, FIRE PROTECTION SHAFT WALL, AIRTIGHT and DUST-PROOF, as well as DISINFECTANT-RESISTANT fill joint between ceiling/wall surface and gypsum board frame with Knauf Joint Tape KURT, or with Fireboard using Glass Fiber Joint Tape.

    It is not necessary to fill or skim the joint be-tween hatch frame and hatch face when using flush bonded gypsum boards (REVO/F-TEC) up to Q2; otherwise skim coat panel on the entire surface with Uniflott; use Fireboard Filler if using fire-resistant access panels with Fireboard face.For surface qualilty level Q3 with REVO/F-TEC: Scrape skim hatch face.Configuration for quality level Q4 on request. Af-ter filling, thoroughly clean outer frame, hatch, and particularly seal.

    19

  • A declaration of compliance specifi ed for your project is available from Knauf Direct Technical Advisory Service.

    s aee

    All technical changes reserved. Only the current printed instructions are valid. Our warranty is expressly limited to our products in flawless condition. All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areas. The stated information represents current state-of-the-art Knauf technology. The entire state of approved en-gineering rules, appropriate standards, guidelines, and rules of craftsmanship are not included herewith. These and all application instructions have to be adhered to separately by the installer. All rights reserved. All amendments, reprints and photocopies, including those of excerpts, require the express permission of Knauf Gips KG, Am Bahnhof 7, 97346 Iphofen, Germany. Delivery via professional building material distributors only, in accordance with our current business, delivery and payment terms.

    The constructional and structural properties, and characteristic building physics of Knauf systems can solely be en-sured with the exclusive use of Knauf system components, or other products expressly recommended by Knauf.

    Knauf Drywall and Floor Systems Am Bahnhof 7, 97346 Iphofen, Germany

    Phone.: +49 9001 31-1000 *

    Knauf DirectTechnical Advisory Service:

    Fax: +49 1805 31-4000 **

    * A rate of 0.39 € per minute will be charged for calls from within the German landline network. Callers whose phone numbers are not registered in the address database of Knauf Gips KG, i.e. private builders or non-patrons, will be charged a rate of 1.69 € per minute. Calls from mobile phones will be charged 1.48 € per minute.

    ** 0,14 €/Min.

    www.knauf.de

    Knauf alutop® Access PanelsDeclarations of Compliance

    Declaration of compliance by the installer of the building component

    Installer: .................................................................................................................................................................................................(name, address) .................................................................................................................................................................................................

    Site / building: .................................................................................................................................................................................................

    Date of installation: .................................................................................................................................................................................................

    Building Component / .................................................................................................................................................................................................requirements: .................................................................................................................................................................................................

    It is certifi ed herewith that the Knauf Access alutop® Panel(s) as stated above has/have been built and installed in accordance with

    Knauf Technical Data Sheet TRO50 Knauf alutop® Access Panels, edition 2008-02

    with the system components specified there, and has/have therefore been built regarding the declaration of compliance by the system manufacturer below in accordance with the valid building supervisory proofs concerning statics, sound insulation and fire protection.

    .............................................................................................................. ..........................................................................................................Place, date Stamp and signature

    Declaration of compliance by the system manufacturer

    Knauf Gips KGAm Bahnhof 797346 Iphofen, Germany

    It is certifi ed herewith that the construction variants, application details and specifi ed products included iniKnauf Technical Data Sheet TRO50 Knauf alu-top® Access Panels, edition 2008-02 are fully in accordance with the specified valid building supervisory proofs respectively.

    As far as specified for the respective system / detail, this applies particularly to ■ the fire resistance acc. to ABP P-3400/4965-MPA BS, ABP P-3935/4719-MPA BS, ABP P-3964/2172-MPA BS, ABP P-3085/3824-MPA BS, ABP P-3310/563/07-

    MPA BS, ABP P-3077/0679-MPA BS, ABP P-3078/0689-MPA BS, ABP P-3079/0699-MPA BS, ABP P-3969/2222-MPA BS, ABP P-3295/2366-MPA BS

    To fullfill the building supervisory requirements specified above in the installation of Knauf ceiling systems, building and application have to be done accord-ing to the valid edition of Knauf Technical Data Sheet TRO50 with system components specified there. This has to be certified by the installer of the compo-nent with the declaration of compliance (see above) towards the contractor.

    Iphofen, February 2008

    Prof. Dr. Hummel Dr. Ruf

    TRO50/engl./D/02.08/FB/D

    Ss

    Dry

    SSasSamanufacture

    Samruction variants, application d

    -02 are fully in accordance with the

    system / detail, this applies particuesistance acc. PA BS, ABP P-3935/

    A BS, ABP P-3077/0679-MPA BS, ABP P-3078/0689-MPA BS