Kiev Conference March 2 , 2013Ken Kopp, FCLSA

Paragon Vision SciencesMesa, Arizona USA

Translation : Dr. Andrey Kovalev

Page 2: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Paragon Vision SciencesWorldwide distributor of gas permeable materials since

1975Over 400 authorized laboratory customers in all

continents.Entered the finished lens market with overnight Corneal

Refractive Therapy (CRT) lens in June of 2002.Added the RG-4 traditional Ortho K design for the US

market in 2008CRT Dual Axis design launched in 2009CRT Software offered in 2012Large diameter GP materials and finished lenses in 2012SilOWet, silicone hydrogel material , introduced in 2013

Page 3: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Core Products/HDS Family

Large diameter GP blanks up to 21.8 mm – HDS100 only

Page 4: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Core Products/Fluoroperm Family

UV available in all FluoroPerm materials

Page 5: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Core Products/Other GP MaterialsOptacryl – Dk 14

FSA 38 – Dk 38

FSA 52 - Dk 52

Paraperm O2/EW O2 – Dk 16 EW – Dk 50

UV absorber is available in some materials. Check with your laboratory.

Page 6: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Core Products/Silicone HydrogelSilOWet™ – a premium soft lens material that

has the following properties;

60 Dk at 35○ C

Lucifilcon A (non-ionic)

Water content 69% @ 20○ C

Modulus – 0.13

Page 7: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Paragon Corneal Reshaping Products

*Currently available in North America only

*

Page 8: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Introducing the CRT Software Package

Page 9: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

CRT Initial Lens Selector

Page 10: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Software Design Assist for Initial Lens Selection Accuracy

Page 11: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

CRT Software FeaturesImport patient files from the topographer Candidate selection for a specific design

Ability to manipulate parameters for optimum tear patterns

Electronic ordering (international distributors pending)

Page 12: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Compatibility LinksKeratron Scout/Piccalo

Medmont Studio 4/5

Oculus EasyGraph/Keratograph

Humphrey Atlas 900 Series, CZM Atlas Model 9000, Tomey versions 1-4, and Pentacam files can be imported to the CRT software but not linked directly to the unit.

Page 13: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

CRT Design Choice

Page 14: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Simulated Tear Pattern With Initial Lens Parameters - CRT

Page 15: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Simulated Tear Pattern With Initial Lens Parameters – CRT DA

Page 16: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Freedom to Alter Tear Pattern for Optimum Appearance

Change all parameters – BC/RZD/LZA/Diameter

Rotate Dual Axis design to observe tear pattern changes

Reset button to return to original settings and/or click OK to begin ordering sequence or return to the home page

Page 17: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Large Diameter GP Lens Designs

Page 18: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

ICD 16.5 is a lens design created by Dr. John Mountford, Patrick Caroline, and Randy Kojima. Paragon recently licensed the product to offer the marketplace to their distributors for manufacture.

NormalEyes 15.5 is a lens design created by Dr. Jerry Legerton and Dr. Bill Meyers for Paragon Vision. The nomenclature is the same as the Paragon CRT lens. (BC/RZD/LZA). This product is manufactured by Paragon

Both lens designs; vault the cornea and the limbus while resting on the sclera.incorporate the use of an tangent periphery to match the

angle of the limbal/scleral junction.are manufactured from Paragon HDS100 material.

Page 19: Ken Kopp, FCLSA Paragon Vision Sciences Mesa, Arizona USA Translation : Dr. Andrey Kovalev

Thank you for your