jetcomjetcom 82 hs 9 8 5 4 3 2 7 6 voltage 50 hz 1x220-240 v ∼ 3x230-400 v ∼ 0,85 0,86 0,6 0,6...

4
DAB PUMPS reserve the right to make modifications without prior notice 15 GENERAL DATA Applications Self-priming centrifugal pump with excellent suction capacity even when there are air bubbles and small particles of sand in the water. Used especially for supplying water to domestic installations. Ideal for use in small-scale agriculture and gardening, limited industrial services and wherever self-priming operation is necessary. Constructional features of the pump Technopolymer pump body and die-cast aluminium motor support. Technopolymer impeller, diffuser, Venturi tube and sand guard. Stainless steel pressure disc. Carbon/ceramic mechanical seal. Constructional features of the motor Induction motor, closed and cooled with external ventilation. Rotor mounted on oversized greased sealed-for-life ball bearings to ensure silent running and long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. Three-phase motors should be protected with a suitable overload protection complying with the regulations in force. Manufactured according to CEI 2-3 and CEI 61-69 standards (EN 60335-2-41). Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: single-phase 220-240 V/50 Hz three-phase 230-400 V/50 Hz JETCOM 1 4 28 7 3 16 160 N. 1 4 7 16 28 36 160 PARTS* PUMP BODY IMPELLER SHAFT WITH ROTOR MECHANICAL SEAL OR GASKET SEAL COVER NOZZLE-VENTURI DIFFUSER ASSEMBLY MATERIALS TECHNOPOLYMER A TECHNOPOLYMER A STAINLESS STEEL AISI 416 X12 CrS13 - UNI 6900/71 CARBON/CERAMIC NBR RUBBER STAINLESS STEEL AISI 304 X5 CRNi 1810 - UNI 6900/71 TECHNOPOLYMER A * In contact with the liquid. TECHNICAL DATA

Upload: others

Post on 07-Aug-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: JETCOMJETCOM 82 Hs 9 8 5 4 3 2 7 6 VOLTAGE 50 Hz 1x220-240 V ∼ 3x230-400 V ∼ 0,85 0,86 0,6 0,6 0,8 0,8 3,8 2,8-1,6 12,5 – 450 – H (m) P1 MAX kW In A P2 NOMINAL …

DAB PUMPS reserve the right to make modifications without prior notice 15

GENERAL DATA

ApplicationsSelf-priming centrifugal pump with excellent suction capacity even when there are air bubbles and smallparticles of sand in the water.Used especially for supplying water to domestic installations. Ideal for use in small-scale agriculture andgardening, limited industrial services and wherever self-priming operation is necessary.

Constructional features of the pumpTechnopolymer pump body and die-cast aluminium motor support.Technopolymer impeller, diffuser, Venturi tube and sand guard.Stainless steel pressure disc.Carbon/ceramic mechanical seal.

Constructional features of the motorInduction motor, closed and cooled with external ventilation.Rotor mounted on oversized greased sealed-for-life ball bearings to ensure silent running and long life.Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phaseversion.Three-phase motors should be protected with a suitable overload protection complying with theregulations in force.Manufactured according to CEI 2-3 and CEI 61-69 standards (EN 60335-2-41).Motor protection: IP 44Terminal box protection: IP 55Insulation class: FStandard voltage: single-phase 220-240 V/50 Hz

three-phase 230-400 V/50 Hz

JETCOM

1 4 28 7

316160

N.1

47

162836

160

PARTS*PUMP BODY

IMPELLERSHAFT WITH ROTOR

MECHANICAL SEALOR GASKETSEAL COVER

NOZZLE-VENTURIDIFFUSER ASSEMBLY

MATERIALSTECHNOPOLYMER A

TECHNOPOLYMER ASTAINLESS STEEL AISI 416X12 CrS13 - UNI 6900/71CARBON/CERAMICNBR RUBBERSTAINLESS STEEL AISI 304X5 CRNi 1810 - UNI 6900/71TECHNOPOLYMER A

* In contact with the liquid.

TECHNICAL DATA

Page 2: JETCOMJETCOM 82 Hs 9 8 5 4 3 2 7 6 VOLTAGE 50 Hz 1x220-240 V ∼ 3x230-400 V ∼ 0,85 0,86 0,6 0,6 0,8 0,8 3,8 2,8-1,6 12,5 – 450 – H (m) P1 MAX kW In A P2 NOMINAL …

A

C

EF

I

G

B

DNM

H2

DN

A

H

DAB PUMPS reserve the right to make modifications without prior notice 16

- Operating range: from 0.6 to 5.4 m3/h with head up to 54 metres- Liquid quality requirements: clean, free from solids or abrasive substances,

non viscous, non aggressive, non crystallized, chemicallyneutral, close to the characteristics of water.

- Liquid temperature range: from 0°C to +35°C for domestic use (EN 60335-2-41)from 0°C to +40°C for other uses

- Maximum suction depth: 8 metres- Maximum ambient temperature: +40°C- Maximum operating pressure: 6 bar (600 kPa)- Installation: fixed or portable in a horizontal position- Special executions on request: other voltages and/or frequencies

t (sec) Tempo di adescamento

0 10 20 30 40 50 60 70 80 90 1000 0

1

2

3

4

5

6

7

8

9

10

Hs

(m) A

ltezz

a di

asp

irazi

one

5

10

15

20

25

30

H(ft)

G 1DN 25

t (sec) Tempo di adescamento

0 10 20 30 40 50 60 70 80 90 1000 0

1

2

3

4

5

6

7

8

9

10

Hs

(m) A

ltezz

a di

asp

irazi

one

5

10

15

20

25

30

H(ft)

Self priming capacity

A B C E F G H H1 H2 I L DNA DNM

406 170 122 208 14 111 198 – 144 9 – 1” G 1” G 470 240 240 0,027 7,5

MODEL

JETCOM 62

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

WEIGHTKg

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

0,72

0,67

0,44

0,44

0,6

0,6

3,12

2,1-1,2

12,5

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

µF Vc

Qm3/hl/min

42

Q00

35

Q0,610

29,2

Q1,220

25,6

Q1,830

22,9

Q2,440

21,1

Q2,745

Q3,660

MODEL

JETCOM 62 M

JETCOM 62 T

ELECTRICAL DATA HYDRAULIC DATA (n ∼ 2800 1/min)

The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

Liquid temperature range: from 0 °C to +35°C Maximum ambient temperature: +40°C

JETCOM 62

Q m3/h0 0,5 1 1,5 2 2,5 30

10

20

30

40

0

20

40

60

80

100

120

0

0

0

Q l/s

Q l/min

Q IMP gpm

Q US gpm

0

0

0,2 0,4 0,6 0,8

10 20 30 40 50

Hm

Hft

PkPa

100

200

300

400

2 4 6 8 10 12

2 4 6 8 10

JETCOM 62

8

6 5 4

2

Hs 9

7

3

Hs

(m) S

uctio

n he

ight

t (sec) Priming time

Hs

(m) S

uctio

n he

ight

t (sec) Priming time

Page 3: JETCOMJETCOM 82 Hs 9 8 5 4 3 2 7 6 VOLTAGE 50 Hz 1x220-240 V ∼ 3x230-400 V ∼ 0,85 0,86 0,6 0,6 0,8 0,8 3,8 2,8-1,6 12,5 – 450 – H (m) P1 MAX kW In A P2 NOMINAL …

A

C

EF

I

G

B

DNM

H2

DN

A

H

A

C

EF

I

G

B

DNM

H2

DN

A

H

DAB PUMPS reserve the right to make modifications without prior notice 17

The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

Liquid temperature range: from 0 °C to +35°C Maximum ambient temperature: +40°C

JETCOM 82

A B C E F G H H1 H2 I L DNA DNM

406 170 122 208 14 111 198 – 144 9 – 1” G 1” G 470 240 240 0,027 7,7

MODEL

JETCOM 82

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

WEIGHTKg

Q m3/h0 0,5 1 1,5 2 2,5 3 3,5 40

10

20

30

40

50

0

20

40

60

80

100

120

160

0

0

0

Q l/s

Q l/min

Q IMP gpm

Q US gpm

0

0

0,2 0,4 0,6 0,8 1

10 20 30 40 50 60

Hm H

ft

PkPa

100

200

300

400

2 4 6 8 10 12 14 16

2 4 6 8 10 12 14

JETCOM 82

Hs 9

8

5 43 2

7 6

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

0,85

0,86

0,6

0,6

0,8

0,8

3,8

2,8-1,6

12,5

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

µF Vc

Qm3/hl/min

47

Q00

40

Q0,610

34

Q1,220

30

Q1,830

26,2

Q2,440

23,5

Q350

20,3

Q3,660

MODEL

JETCOM 82 M

JETCOM 82 T

ELECTRICAL DATA HYDRAULIC DATA (n ∼ 2800 1/min)

Liquid temperature range: from 0 °C to +35°C Maximum ambient temperature: +40°C

JETCOM 102

A B C E F G H H1 H2 I L DNA DNM

425 170 122 208 14 111 203 – 144 9 – 1” G 1” G 470 240 240 0,027 9,5

MODEL

JETCOM 102

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

WEIGHTKg

Q m3/h0 0,5 1 1,5 2 2,5 3 3,5 40

10

20

30

40

50

0

20

40

60

80

100

120

160

0

0

0

Q l/s

Q l/min

Q IMP gpm

Q US gpm

0

0

0,2 0,4 0,6 0,8 1

10 20 30 40 50 60

Hm H

ft

PkPa

100

200

300

400

2 4 6 8 10 12 14 16

2 4 6 8 10 12 14

JETCOM 102

Hs 98

7

42

65

3

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

1,13

1,04

0,75

0,75

1

1

5,1

3,3-1,9

16

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

µF Vc

Qm3/hl/min

53,8

Q00

47

Q0,610

41

Q1,220

36,3

Q1,830

32,4

Q2,440

28,8

Q350

25,8

Q3,660

MODEL

JETCOM 102 M

JETCOM 102 T

ELECTRICAL DATA HYDRAULIC DATA (n ∼ 2800 1/min)

Page 4: JETCOMJETCOM 82 Hs 9 8 5 4 3 2 7 6 VOLTAGE 50 Hz 1x220-240 V ∼ 3x230-400 V ∼ 0,85 0,86 0,6 0,6 0,8 0,8 3,8 2,8-1,6 12,5 – 450 – H (m) P1 MAX kW In A P2 NOMINAL …

A

C

EF

I

G

B

DNM

H2

DN

A

H

A

C

EF

I

G

B

DNM

H2

DN

A

H

DAB PUMPS reserve the right to make modifications without prior notice 18

Liquid temperature range: from 0 °C to +35°C Maximum ambient temperature: +40°C

JETCOM 132

A B C E F G H H1 H2 I L DNA DNM

425 170 122 208 14 111 203 – 144 9 – 1” G 1” G 470 240 240 0,027 8,7

MODEL

JETCOM 92

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

WEIGHTKg

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

0,94

0,93

0,75

0,75

1

1

4,2

3,3-1,9

14

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

µF Vc

Qm3/hl/min

36,2

Q00

33,5

Q0,610

31

Q1,220

28,4

Q1,830

26

Q2,440

24

Q350

21,8 19,6 17

Q3,660

Q4,270

Q4,880

MODEL

JETCOM 92 M

JETCOM 92 T

ELECTRICAL DATA HYDRAULIC DATA (n ∼ 2800 1/min)

The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

Liquid temperature range: from 0 °C to +35°C Maximum ambient temperature: +40°C

JETCOM 92

Q m3/h0 1 2 3 4 50 0

20

40

60

80

100

120

140

0

00

Q l/sQ l/min

Q IMP gpmQ US gpm

0

0

0,2 0,4 0,6 0,8 1 1,2 1,4

10 20 30 40 50 60 70 80 90

Hm

Hft

PkPa

10100

20200

30300

40400

2 4 6 8 10 12 14 16 18 20 22 242 4 6 8 10 12 14 16 18 20

Hs8

2

75 4

3

JETCOM 92

9

6

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

1,49

1,43

1

1

1,36

1,36

6,6

4,7-2,7

25

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

µF Vc

Qm3/hl/min

48

Q00

45,6

Q0,610

42,8

Q1,220

40

Q1,830

37,6

Q2,440

35

Q350

32,5 30 27

Q3,660

Q4,270

Q4,880

MODEL

JETCOM 132 M

JETCOM 132 T

ELECTRICAL DATA HYDRAULIC DATA (n ∼ 2800 1/min)

A B C E F G H H1 H2 I L DNA DNM

425 170 122 208 14 111 203 – 144 9 – 1” G 1” G 470 240 240 0,027 10,5

MODEL

JETCOM 132

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

WEIGHTKg

Q m3/h0 1 2 3 4 50 0

20

40

60

80

100

120

140

0

00

Q l/sQ l/min

Q IMP gpmQ US gpm

0

0

0,2 0,4 0,6 0,8 1 1,2 1,4

10 20 30 40 50 60 70 80 90

Hm

Hft

PkPa

10100

20200

30300

40400

2 4 6 8 10 12 14 16 18 20 22 242 4 6 8 10 12 14 16 18 20

Hs8

6

2

7

54

3

JETCOM 132

9