j45537-1 nj full package final report

323
ANALYTICAL REPORT Job Number: 460-45537-1 Job Description: 17338-TO4-2012, RACER, GM Wilmington For: Conestoga-Rovers & Associates, Inc. 2055 Niagara Falls Blvd., Suite 3 Niagara Falls, NY 14304 Attention: Ms. Sue Scrocchi _____________________________________________ Approved for release. Janet Mosley Project Mgmt. Assistant 10/16/2012 2:43 PM Designee for Jamie Capaci Project Manager I [email protected] 10/16/2012 cc: Chris Barton The test results in this report meet all NELAP requirements unless specified within the case narrative. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory. All questions regarding this report should be directed to the TestAmerica Edison Project Manager. TestAmerica Edison Certifications and Approvals: Connecticut: CTDOH #PH-0200, New Jersey: NJDEP (NELAP) #12028, New York: NYDOH (NELAP) #11452, NYDOH (ELAP) #11452, Pennsylvania: PADEP (NELAP) 68-00522 and Rhode Island: RIDOH LAO00132 TestAmerica Laboratories, Inc. TestAmerica Edison 777 New Durham Road, Edison, NJ 08817 Tel (732) 549-3900 Fax (732) 549-3679 www.testamericainc.com 10/16/2012 Page 1 of 323

Upload: others

Post on 27-Feb-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: J45537-1 Nj Full Package Final Report

ANALYTICAL REPORT

Job Number 460-45537-1

Job Description 17338-TO4-2012 RACER GM Wilmington

ForConestoga-Rovers amp Associates Inc

2055 Niagara Falls Blvd Suite 3Niagara Falls NY 14304

Attention Ms Sue Scrocchi

_____________________________________________

Approved for releaseJanet MosleyProject Mgmt Assistant10162012 243 PM

Designee forJamie Capaci

Project Manager Ijamiecapacitestamericainccom

10162012

cc Chris Barton

The test results in this report meet all NELAP requirements unless specified within the case narrative Pursuant toNELAP this report may not be reproduced except in full without the written approval of the laboratory All questionsregarding this report should be directed to the TestAmerica Edison Project Manager

TestAmerica Edison Certifications and Approvals Connecticut CTDOH PH-0200 New Jersey NJDEP (NELAP)12028 New York NYDOH (NELAP) 11452 NYDOH (ELAP) 11452 Pennsylvania PADEP (NELAP) 68-00522 andRhode Island RIDOH LAO00132

TestAmerica Laboratories Inc

TestAmerica Edison 777 New Durham Road Edison NJ 08817

Tel (732) 549-3900 Fax (732) 549-3679 wwwtestamericainccom

10162012Page 1 of 323

Table of ContentsCover Title Page 1

Data Summaries 4

Report Narrative 4

Sample Summary 5

Executive Summary 6

Method Summary 7

Method Analyst Summary 8

Sample Datasheets 9

Surrogate Summary 22

QC Data Summary 24

Data Qualifiers 35

QC Association Summary 36

Lab Chronicle 37

Organic Sample Data 39

GCMS VOA 39

Method 8260 DEL 39Method 8260 DEL QC Summary 40Method 8260 DEL Sample Data 51Standards Data 72

Method 8260 DEL ICAL Data 72Method 8260 DEL CCAL Data 96

Raw QC Data 106Method 8260 DEL Tune Data 106Method 8260 DEL Blank Data 114Method 8260 DEL LCSLCSD Data 119Method 8260 DEL MSMSD Data 124

10162012Page 2 of 323

Table of ContentsMethod 8260 DEL Run Logs 134Method 8260 DEL Prep Data 136

GC Semi VOA 140

Method 8082 - Delaware 140Method 8082 - Delaware QC Summary 141Method 8082 - Delaware Sample Data 151Standards Data 163

Method 8082 - Delaware ICAL Data 163Method 8082 - Delaware CCAL Data 256

Raw QC Data 276Method 8082 - Delaware Blank Data 276Method 8082 - Delaware LCSLCSD Data 294

Method 8082 - Delaware Run Logs 314Method 8082 - Delaware Prep Data 316

Shipping and Receiving Documents 321

Client Chain of Custody 322

Sample Receipt Checklist 323

10162012Page 3 of 323

CASE NARRATIVE

Client Conestoga-Rovers amp Associates Inc

Project 17338-TO4-2012 RACER GM Wilmington

Report Number 460-45537-1

This case narrative is in the form of an exception report where only the anomalies related to this report method specific performance

andor QAQC issues are discussed If there are no issues to report this narrative will include a statement that documents that there are

no relevant data issues

It should be noted that samples with elevated Reporting Limits (RLs) as a result of a dilution may not be able to satisfy customer reporting

limits in some cases Such increases in the RLs are unavoidable but acceptable consequence of sample dilution that enables

quantification of target analytes or interferences which exceed the calibration range of the instrument

Calculations are performed before rounding to avoid round-off errors in calculated results

All holding times were met and proper preservation noted for the methods performed on these samples unless otherwise detailed in the

individual sections below

RECEIPT

The samples were received on 10052012 710 PM the samples arrived in good condition properly preserved and on ice The

temperature of the coolers at receipt was 32 C

Note All samples which require thermal preservation are considered acceptable if the arrival temperature is within 2C of the required

temperature or method specified range For samples with a specified temperature of 4C samples with a temperature ranging from just

above freezing temperature of water to 6C shall be acceptable Samples that are hand delivered immediately following collection may not

meet these criteria however they will be deemed acceptable according to NELAC standards if there is evidence that the chilling process

has begun such as arrival on ice etc

POLYCHLORINATED BIPHENYLS (PCBS)

Samples 460-45537-1 and 460-45537-2 were analyzed for polychlorinated biphenyls (PCBs) in accordance with EPA SW-846 Method

8082DEL The samples were prepared on 10082012 and analyzed on 10092012

No difficulties were encountered during the PCBs analyses

All quality control parameters were within the acceptance limits

VOLATILE ORGANIC COMPOUNDS (GC-MS)

Samples 460-45537-1 through 460-45537-3 were analyzed for volatile organic compounds (GC-MS) in accordance with EPA SW-846

Method 8260B The samples were analyzed on 10112012 and 10122012

The matrix spike matrix spike duplicate (MSMSD) recoveries for batch 131656 were outside control limits 12-Dibromo-3-chloropropane

The MSD recoveries were also outside control limits for trans-13-Dichloropropene and Methyl tert-butyl ether The associated laboratory

control sample (LCS) recoveries met acceptance criteria

12-Dibromo-3-Chloropropane failed the recovery criteria high for the MS of sample 460-45537-2 in batch 460-131656

12-Dibromo-3-Chloropropane Methyl tert-butyl ether and trans-13-Dichloropropene failed the recovery criteria high for the MSD of

sample 460-45537-2 in batch 460-131656

Refer to the QC report for details

No other difficulties were encountered during the volatiles analyses

All other quality control parameters were within the acceptance limits

10162012Page 4 of 323

SAMPLE SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample IDLab Sample ID Client Matrix Sampled Received

DateTime DateTime

460-45537-1 WC-17338-100512-MW14-MM-2

51

Water 10052012 1000 10052012 1910

460-45537-2 WC-17338-100512-MW101-MM-

252

Water 10052012 1230 10052012 1910

460-45537-3TB TB-17338-100512-253 Water 10052012 0000 10052012 1910

TestAmerica Edison 10162012Page 5 of 323

EXECUTIVE SUMMARY - Detections

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Analyte Result

Reporting

Limit Units Method

Lab Sample ID Client Sample ID

Qualifier

460-45537-1 WC-17338-100512-MW14-MM-251

10 ugL 8260B017 JMethyl tert-butyl ether

10 ugL 8260B017 JToluene

10 ugL 8260B028 JTetrachloroethene

460-45537-2 WC-17338-100512-MW101-MM-252

10 ugL 8260B020 JMethyl tert-butyl ether

460-45537-3TB TB-17338-100512-253

10 ugL 8260B074 JMethylene Chloride

10 ugL 8260B0096 JChloroform

TestAmerica Edison 10162012Page 6 of 323

METHOD SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Preparation MethodMethodLab LocationDescription

Matrix Water

Volatile Organics (GCMS) TAL EDI SW846 8260B

Purge and Trap TAL EDI SW846 5030B

Polychlorinated Biphenyls (PCBs) (GC) TAL EDI SW846 8082

Liquid-Liquid Extraction (Separatory Funnel) TAL EDI SW846 3510C

Lab References

TAL EDI = TestAmerica Edison

Method References

SW846 = Test Methods For Evaluating Solid Waste PhysicalChemical Methods Third Edition November 1986 And Its Updates

TestAmerica Edison 10162012Page 7 of 323

METHOD ANALYST SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Method Analyst Analyst ID

Boykin Kenneth KBSW846 8260B

Boykin Carol B CBBSW846 8082

TestAmerica Edison

10162012Page 8 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

017 J 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

017 J 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

028 J 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 9 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

99 70 - 1304-Bromofluorobenzene

96 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 10 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 11 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

020 J 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 12 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

98 70 - 1304-Bromofluorobenzene

97 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 13 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 14 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

074 J 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

014 U 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0096 J 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 15 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

99 70 - 1304-Bromofluorobenzene

97 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 16 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 17 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0029

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type PRIMARY

980 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

013 U 051013PCB-1016

029 U 051029PCB-1221

012 U 051012PCB-1232

012 U 051012PCB-1242

024 U 051024PCB-1248

017 U 051017PCB-1254

015 U 051015PCB-1260

Surrogate Rec Acceptance LimitsQualifier

83 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 18 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0029

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type SECONDARY

980 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Surrogate Rec Acceptance LimitsQualifier

82 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 19 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0045

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type PRIMARY

990 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

013 U 051013PCB-1016

028 U 051028PCB-1221

012 U 051012PCB-1232

012 U 051012PCB-1242

024 U 051024PCB-1248

017 U 051017PCB-1254

015 U 051015PCB-1260

Surrogate Rec Acceptance LimitsQualifier

52 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 20 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0045

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type SECONDARY

990 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Surrogate Rec Acceptance LimitsQualifier

50 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 21 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Surrogate Recovery Report

8260B Volatile Organics (GCMS)

Client Matrix Water

Lab Sample ID Client Sample ID

DCA TOL BFB

Rec Rec Rec

460-45537-1 WC-17338-100512-M

W14-MM-251

97 96 99

460-45537-2 WC-17338-100512-M

W101-MM-252

97 97 98

460-45537-3 TB-17338-100512-25

3

97 97 99

MB 460-1316564 99 96 95

LCS 460-1316563 96 99 97

460-45537-2 MS WC-17338-100512-M

W101-MM-252 MS

96 99 99

460-45537-2 MSD WC-17338-100512-M

W101-MM-252 MSD

96 99 97

Surrogate Acceptance Limits

DCA = 12-Dichloroethane-d4 (Surr) 70-130

TOL = Toluene-d8 (Surr) 70-130

BFB = 4-Bromofluorobenzene 70-130

TestAmerica Edison

10162012Page 22 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Surrogate Recovery Report

8082 Polychlorinated Biphenyls (PCBs) (GC)

Client Matrix Water

Lab Sample ID Client Sample ID

DCB1 DCB2

Rec Rec

460-45537-1 WC-17338-100512-M

W14-MM-251

82 83

460-45537-2 WC-17338-100512-M

W101-MM-252

52 50

MB 460-1309971-A 97 88

LCS 460-1309972-A 91 84

LCSD

460-1309973-A

108 99

Surrogate Acceptance Limits

DCB = DCB Decachlorobiphenyl 37-150

TestAmerica Edison

10162012Page 23 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-131656

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08981d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5MB 460-1316564

Analysis Date 10112012 2247

Analysis Batch

Prep Batch

Leach Batch

NA

NA

460-131656

Prep Date

Leach Date

10112012 2247

NA

Analyte RLMDLQualResult

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

014 U 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

TestAmerica Edison 10162012Page 24 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-131656

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08981d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5MB 460-1316564

Analysis Date 10112012 2247

Analysis Batch

Prep Batch

Leach Batch

NA

NA

460-131656

Prep Date

Leach Date

10112012 2247

NA

Analyte RLMDLQualResult

014 U 1001413-Dichlorobenzene

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance Limits

12-Dichloroethane-d4 (Surr) 99 70 - 130

4-Bromofluorobenzene 95 70 - 130

Toluene-d8 (Surr) 96 70 - 130

Method Blank TICs- Batch 460-131656

Cas Number Analyte RT Est Result Qual

Tentatively Identified Compound None

TestAmerica Edison 10162012Page 25 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10

Lab Control Sample - Batch 460-131656

Client Matrix

Lab Sample ID

Dilution

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08977d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5LCS 460-1316563

Analysis Date 10112012 2113

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Prep Date

Leach Date

10112012 2113

NA

Analyte QualLimit RecResultSpike Amount

200 210 105 74 - 128111-Trichloroethane

200 181 90 46 - 145Dichlorodifluoromethane

200 210 105 58 - 146Chloromethane

200 203 101 61 - 144Vinyl chloride

200 211 105 55 - 153Bromomethane

200 222 111 70 - 11612-Dibromo-3-Chloropropane

200 209 104 82 - 12212-Dichlorobenzene

200 190 95 69 - 147Trichlorofluoromethane

200 223 112 56 - 13911-Dichloroethene

200 211 106 80 - 12012-Dichloropropane

200 203 102 47 - 139112-Trichloro-122-trifluoroethane

200 250 125 45 - 156Acetone

200 218 109 58 - 139Carbon disulfide

200 220 110 50 - 151Methyl acetate

200 200 100 79 - 119Methylene Chloride

200 216 108 75 - 122trans-12-Dichloroethene

200 217 109 80 - 120Chlorodibromomethane

200 207 104 71 - 115Methyl tert-butyl ether

200 201 101 69 - 145Chloroethane

200 204 102 78 - 12211-Dichloroethane

200 211 106 80 - 120cis-12-Dichloroethene

200 214 107 65 - 1142-Butanone (MEK)

200 205 103 82 - 123Chloroform

200 206 103 79 - 126Ethylbenzene

200 208 104 58 - 133Cyclohexane

200 211 105 73 - 120Carbon tetrachloride

200 212 106 83 - 124Benzene

200 204 102 74 - 11812-Dichloroethane

200 212 106 78 - 119Trichloroethene

200 215 107 61 - 129Methylcyclohexane

200 214 107 79 - 119Dichlorobromomethane

200 216 108 80 - 120cis-13-Dichloropropene

200 214 107 53 - 1204-Methyl-2-pentanone (MIBK)

200 205 103 80 - 120Toluene

200 215 108 78 - 118trans-13-Dichloropropene

200 217 109 79 - 119112-Trichloroethane

200 210 105 68 - 139Tetrachloroethene

200 201 100 53 - 1212-Hexanone

200 215 107 78 - 11812-Dibromoethane

200 206 103 81 - 121Chlorobenzene

600 612 102 76 - 121Xylenes Total

200 207 104 69 - 112Styrene

200 217 109 73 - 123Bromoform

200 207 104 80 - 125Isopropylbenzene

200 210 105 74 - 1261122-Tetrachloroethane

200 204 102 81 - 12613-Dichlorobenzene

TestAmerica Edison 10162012Page 26 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10

Lab Control Sample - Batch 460-131656

Client Matrix

Lab Sample ID

Dilution

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08977d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5LCS 460-1316563

Analysis Date 10112012 2113

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Prep Date

Leach Date

10112012 2113

NA

Analyte QualLimit RecResultSpike Amount

200 204 102 83 - 12314-Dichlorobenzene

200 220 110 66 - 120124-Trichlorobenzene

Surrogate Rec Acceptance Limits

12-Dichloroethane-d4 (Surr) 96 70 - 130

4-Bromofluorobenzene 97 70 - 130

Toluene-d8 (Surr) 99 70 - 130

TestAmerica Edison 10162012Page 27 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Water

50

50

Client Matrix

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Client Matrix Water

e08985d

5 mL

5 mL

e08986d

5 mL

5 mL

Method 8260B

Preparation 5030B

VOAMS5

VOAMS5

460-45537-2

460-45537-2

MS Lab Sample ID

MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

10122012 0051

NA

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

10122012 0027

Analyte RPD LimitRPDLimit

Rec

MS MSD MS Qual MSD Qual

103 106 74 - 128 3 30111-Trichloroethane

87 90 46 - 145 4 30Dichlorodifluoromethane

102 101 58 - 146 0 30Chloromethane

104 105 61 - 144 0 30Vinyl chloride

107 105 55 - 153 2 30Bromomethane

121 121 70 - 116 0 30 F F12-Dibromo-3-Chloropropane

107 111 82 - 122 3 3012-Dichlorobenzene

121 100 69 - 147 19 30Trichlorofluoromethane

108 119 56 - 139 9 3011-Dichloroethene

111 110 80 - 120 0 3012-Dichloropropane

102 111 47 - 139 8 30112-Trichloro-122-trifluoroethane

99 101 45 - 156 2 30Acetone

113 119 58 - 139 5 30Carbon disulfide

100 101 50 - 151 1 30Methyl acetate

106 106 79 - 119 0 30Methylene Chloride

106 108 75 - 122 2 30trans-12-Dichloroethene

116 118 80 - 120 2 30Chlorodibromomethane

114 116 71 - 115 1 30 FMethyl tert-butyl ether

116 105 69 - 145 10 30Chloroethane

104 111 78 - 122 7 3011-Dichloroethane

105 109 80 - 120 4 30cis-12-Dichloroethene

111 114 65 - 114 3 302-Butanone (MEK)

108 113 82 - 123 4 30Chloroform

107 111 79 - 126 3 30Ethylbenzene

108 117 58 - 133 7 30Cyclohexane

105 110 73 - 120 5 30Carbon tetrachloride

106 114 83 - 124 7 30Benzene

107 109 74 - 118 2 3012-Dichloroethane

107 113 78 - 119 5 30Trichloroethene

115 121 61 - 129 5 30Methylcyclohexane

113 116 79 - 119 3 30Dichlorobromomethane

109 115 80 - 120 5 30cis-13-Dichloropropene

111 114 53 - 120 3 304-Methyl-2-pentanone (MIBK)

TestAmerica Edison 10162012Page 28 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Water

50

50

Client Matrix

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Client Matrix Water

e08985d

5 mL

5 mL

e08986d

5 mL

5 mL

Method 8260B

Preparation 5030B

VOAMS5

VOAMS5

460-45537-2

460-45537-2

MS Lab Sample ID

MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

10122012 0051

NA

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

10122012 0027

Analyte RPD LimitRPDLimit

Rec

MS MSD MS Qual MSD Qual

106 111 80 - 120 5 30Toluene

113 119 78 - 118 5 30 Ftrans-13-Dichloropropene

112 116 79 - 119 3 30112-Trichloroethane

110 116 68 - 139 5 30Tetrachloroethene

109 111 53 - 121 2 302-Hexanone

116 117 78 - 118 1 3012-Dibromoethane

107 111 81 - 121 3 30Chlorobenzene

106 110 76 - 121 3 30Xylenes Total

107 110 69 - 112 3 30Styrene

115 114 73 - 123 1 30Bromoform

107 111 80 - 125 4 30Isopropylbenzene

115 116 74 - 126 0 301122-Tetrachloroethane

106 110 81 - 126 4 3013-Dichlorobenzene

106 110 83 - 123 4 3014-Dichlorobenzene

110 119 66 - 120 8 30124-Trichlorobenzene

Surrogate Acceptance LimitsMS Rec MSD Rec

12-Dichloroethane-d4 (Surr) 96 96 70 - 130

4-Bromofluorobenzene 99 97 70 - 130

Toluene-d8 (Surr) 99 99 70 - 130

TestAmerica Edison 10162012Page 29 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10122012 0027 10122012 0051

Dilution Dilution50 50

Client Matrix Client Matrix Water

Method 8260B

Preparation 5030B

Units ugL460-45537-2 460-45537-2MS Lab Sample ID MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

Analysis Date

Prep Date

Leach Date

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

NA

Amount

Sample

Analyte ResultQual Amount ResultQual ResultQual

MS MSDMS Spike MSD Spike

0060 U 100 100 103 106111-Trichloroethane

022 U 100 100 865 896Dichlorodifluoromethane

010 U 100 100 102 101Chloromethane

014 U 100 100 104 105Vinyl chloride

018 U 100 100 107 105Bromomethane

040 U 100 100 121 121F F12-Dibromo-3-Chloropropane

021 U 100 100 107 11112-Dichlorobenzene

015 U 100 100 121 997Trichlorofluoromethane

0090 U 100 100 108 11911-Dichloroethene

0090 U 100 100 111 11012-Dichloropropane

0080 U 100 100 102 111112-Trichloro-122-trifluoroethane

27 U 100 100 986 101Acetone

013 U 100 100 113 119Carbon disulfide

034 U 100 100 100 101Methyl acetate

018 U 100 100 106 106Methylene Chloride

013 U 100 100 106 108trans-12-Dichloroethene

020 U 100 100 116 118Chlorodibromomethane

020 J 100 100 114 116 FMethyl tert-butyl ether

017 U 100 100 116 105Chloroethane

013 U 100 100 104 11111-Dichloroethane

018 U 100 100 105 109cis-12-Dichloroethene

23 U 100 100 111 1142-Butanone (MEK)

0080 U 100 100 108 113Chloroform

010 U 100 100 107 111Ethylbenzene

016 U 100 100 108 117Cyclohexane

0060 U 100 100 105 110Carbon tetrachloride

0080 U 100 100 106 114Benzene

019 U 100 100 107 10912-Dichloroethane

0090 U 100 100 107 113Trichloroethene

014 U 100 100 115 121Methylcyclohexane

012 U 100 100 113 116Dichlorobromomethane

018 U 100 100 109 115cis-13-Dichloropropene

099 U 100 100 111 1144-Methyl-2-pentanone (MIBK)

015 U 100 100 106 111Toluene

024 U 100 100 113 119 Ftrans-13-Dichloropropene

019 U 100 100 112 116112-Trichloroethane

010 U 100 100 110 116Tetrachloroethene

050 U 100 100 109 1112-Hexanone

028 U 100 100 116 11712-Dibromoethane

011 U 100 100 107 111Chlorobenzene

036 U 300 300 318 329Xylenes Total

012 U 100 100 107 110Styrene

019 U 100 100 115 114Bromoform

TestAmerica Edison 10162012Page 30 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10122012 0027 10122012 0051

Dilution Dilution50 50

Client Matrix Client Matrix Water

Method 8260B

Preparation 5030B

Units ugL460-45537-2 460-45537-2MS Lab Sample ID MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

Analysis Date

Prep Date

Leach Date

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

NA

Amount

Sample

Analyte ResultQual Amount ResultQual ResultQual

MS MSDMS Spike MSD Spike

0080 U 100 100 107 111Isopropylbenzene

016 U 100 100 115 1161122-Tetrachloroethane

014 U 100 100 106 11013-Dichlorobenzene

023 U 100 100 106 11014-Dichlorobenzene

034 U 100 100 110 119124-Trichlorobenzene

TestAmerica Edison 10162012Page 31 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-130997

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

vr479496d

1000 mL

5 mLUnits ugL

Method 8082

Preparation 3510C

PESTGC9MB 460-1309971-A

Analysis Date 10082012 2208

Analysis Batch

Prep Batch

Leach Batch NA

460-131137

460-130997

Prep Date Injection Volume

Leach Date

10082012 0755

NA PRIMARYColumn ID

Analyte RLMDLQualResult

013 U 050013PCB-1016

028 U 050028PCB-1221

012 U 050012PCB-1232

012 U 050012PCB-1242

024 U 050024PCB-1248

017 U 050017PCB-1254

015 U 050015PCB-1260

Surrogate Rec Acceptance Limits

DCB Decachlorobiphenyl 97 37 - 150

Surrogate Rec Acceptance Limits

DCB Decachlorobiphenyl 88 37 - 150

TestAmerica Edison 10162012Page 32 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Lab Control Sample

Lab Control Sample Duplicate Recovery Report - Batch 460-130997

10

10

Water

LCS Lab Sample ID

LCSD Lab Sample ID

Client Matrix

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

Client Matrix Water

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

ugL

vf479497d

1000 mL

5 mL

PRIMARY

vf479498d

1000 mL

5 mL

PRIMARY

ugL

Method 8082

Preparation 3510C

PESTGC9

PESTGC9

LCS 460-1309972-A

LCSD 460-1309973-A

Analysis Date

Prep Date

Leach Date

10082012 2224

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

Rec

103101 71 - 126 2 30PCB-1016

119115 73 - 130 4 30PCB-1260

Surrogate LCS Rec LCSD Rec Acceptance Limits

DCB Decachlorobiphenyl 91 108 37 - 150

Dilution

Dilution

Lab Control Sample

Lab Control Sample Duplicate Recovery Report - Batch 460-130997

10

10

Water

LCS Lab Sample ID

LCSD Lab Sample ID

Client Matrix

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

Client Matrix Water

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

ugL

vr479497d

1000 mL

5 mL

SECONDARY

vr479498d

1000 mL

5 mL

SECONDARY

ugL

Method 8082

Preparation 3510C

PESTGC9

PESTGC9

LCS 460-1309972-A

LCSD 460-1309973-A

Analysis Date

Prep Date

Leach Date

10082012 2224

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

Rec

9997 71 - 126 3 30PCB-1016

117111 73 - 130 5 30PCB-1260

Surrogate LCS Rec LCSD Rec Acceptance Limits

DCB Decachlorobiphenyl 84 99 37 - 150

TestAmerica Edison 10162012Page 33 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10082012 2224

Dilution Dilution10 10

Client Matrix

LCSD Lab Sample ID

Client Matrix Water

Laboratory Control

Laboratory Duplicate Data Report - Batch 460-130997

Method 8082

Preparation 3510C

Units ugLLCS 460-1309972-A LCSD 460-1309973-ALCS Lab Sample ID

Analysis Date

Prep Date

Leach Date

10082012 0755

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NANA

LCSD

ResultQual

LCS

ResultQual

LCSD Spike

Amount

LCS Spike

AmountAnalyte

516507500 500PCB-1016

595573500 500PCB-1260

Water

10082012 2224

Dilution Dilution10 10

Client Matrix

LCSD Lab Sample ID

Client Matrix Water

Laboratory Control

Laboratory Duplicate Data Report - Batch 460-130997

Method 8082

Preparation 3510C

Units ugLLCS 460-1309972-A LCSD 460-1309973-ALCS Lab Sample ID

Analysis Date

Prep Date

Leach Date

10082012 0755

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NANA

LCSD

ResultQual

LCS

ResultQual

LCSD Spike

Amount

LCS Spike

AmountAnalyte

497483500 500PCB-1016

583557500 500PCB-1260

TestAmerica Edison 10162012Page 34 of 323

DATA REPORTING QUALIFIERS

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Lab Section Qualifier Description

GCMS VOA

Indicates the analyte was analyzed for but not detectedU

MSMSD Recovery or RPD exceeds the control limitsF

Result is less than the RL but greater than or equal to the MDL and the

concentration is an approximate value

J

GC Semi VOA

Indicates the analyte was analyzed for but not detectedU

TestAmerica Edison 10162012Page 35 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

QC Association Summary

Lab Sample ID Client Sample ID Client Matrix Method Prep Batch

Report

Basis

GCMS VOA

Analysis Batch460-131656

Lab Control Sample Water 8260BLCS 460-1316563 T

Method Blank Water 8260BMB 460-1316564 T

WaterWC-17338-100512-MW14-MM-251 8260B460-45537-1 T

WaterWC-17338-100512-MW101-MM-252 8260B460-45537-2 T

Matrix Spike Water 8260B460-45537-2MS T

Matrix Spike Duplicate Water 8260B460-45537-2MSD T

WaterTB-17338-100512-253 8260B460-45537-3TB T

Report Basis

T = Total

GC Semi VOA

Prep Batch 460-130997

Lab Control Sample Water 3510CLCS 460-1309972-A T

Lab Control Sample Duplicate Water 3510CLCSD 460-1309973-A T

Method Blank Water 3510CMB 460-1309971-A T

WaterWC-17338-100512-MW14-MM-251 3510C460-45537-1 T

WaterWC-17338-100512-MW101-MM-252 3510C460-45537-2 T

Analysis Batch460-131137

Lab Control Sample Water 460-1309978082LCS 460-1309972-A T

Lab Control Sample Duplicate Water 460-1309978082LCSD 460-1309973-A T

Method Blank Water 460-1309978082MB 460-1309971-A T

Water 460-130997WC-17338-100512-MW14-MM-251 8082460-45537-1 T

Water 460-130997WC-17338-100512-MW101-MM-252 8082460-45537-2 T

Report Basis

T = Total

TestAmerica Edison

10162012Page 36 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Laboratory Chronicle

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1000

460-45537-1 WC-17338-100512-MW14-MM-251

P5030B 460-45537-A-1 460-131656 10112012 2341 KBTAL EDI1

A8260B 460-45537-A-1 460-131656 10112012 2341 KBTAL EDI1

P3510C 460-45537-E-1-B 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 460-45537-E-1-B 460-131137 460-130997 10092012 0029 CBBTAL EDI1

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 WC-17338-100512-MW101-MM-252

P5030B 460-45537-A-2 460-131656 10122012 0004 KBTAL EDI1

A8260B 460-45537-A-2 460-131656 10122012 0004 KBTAL EDI1

P3510C 460-45537-E-2-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 460-45537-E-2-A 460-131137 460-130997 10092012 0045 CBBTAL EDI1

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 MS WC-17338-100512-MW101-MM-252

P5030B 460-45537-C-2 MS 460-131656 10122012 0027 KBTAL EDI5

A8260B 460-45537-C-2 MS 460-131656 10122012 0027 KBTAL EDI5

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 MSD WC-17338-100512-MW101-MM-252

P5030B 460-45537-C-2 MSD 460-131656 10122012 0051 KBTAL EDI5

A8260B 460-45537-C-2 MSD 460-131656 10122012 0051 KBTAL EDI5

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 0000

460-45537-3 TB-17338-100512-253

P5030B 460-45537-A-3 460-131656 10112012 2317 KBTAL EDI1

A8260B 460-45537-A-3 460-131656 10112012 2317 KBTAL EDI1

A = Analytical Method P = Prep Method TestAmerica Edison

10162012Page 37 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Laboratory Chronicle

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

MB NA

P5030B MB 460-1316564 460-131656 10112012 2247 KBTAL EDI1

A8260B MB 460-1316564 460-131656 10112012 2247 KBTAL EDI1

P3510C MB 460-1309971-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 MB 460-1309971-A 460-131137 460-130997 10082012 2208 CBBTAL EDI1

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

LCS NA

P5030B LCS 460-1316563 460-131656 10112012 2113 KBTAL EDI1

A8260B LCS 460-1316563 460-131656 10112012 2113 KBTAL EDI1

P3510C LCS 460-1309972-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 LCS 460-1309972-A 460-131137 460-130997 10082012 2224 CBBTAL EDI1

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

LCSD NA

P3510C LCSD

460-1309973-A

460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 LCSD

460-1309973-A

460-131137 460-130997 10082012 2239 CBBTAL EDI1

Lab ReferencesTAL EDI = TestAmerica Edison

A = Analytical Method P = Prep Method TestAmerica Edison

10162012Page 38 of 323

Method 8260 DELVolatile Organics (GCMS) by Method

8260 (Delaware)

10162012Page 39 of 323

FORM II

GCMS VOA SURROGATE RECOVERY

Lab Name Job No 460-45537-1

SDG No

Matrix Water Level Low

TestAmerica Edison

GC Column (1) Rtx-VMS ID 018(mm)

Lab Sample IDClient Sample ID DCA TOL BFB

460-45537-1WC-17338-100512-MW14-MM-251

97 96 99

460-45537-2WC-17338-100512-MW101-MM-252

97 97 98

460-45537-3TB-17338-100512-253

97 97 99

MB 460-1316564 99 96 95

LCS 460-1316563 96 99 97

460-45537-2 MSWC-17338-100512-MW101-MM-252 MS

96 99 99

460-45537-2 MSDWC-17338-100512-MW101-MM-252 MSD

96 99 97

QC LIMITSQC LIMITSDCA = 12-Dichloroethane-d4 (Surr) 70-130

TOL = Toluene-d8 (Surr) 70-130

BFB = 4-Bromofluorobenzene 70-130

FORM II 8260B

Column to be used to flag recovery values

10162012Page 40 of 323

GCMS VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08977dWater

Lab ID LCS 460-1316563 Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

111-Trichloroethane 200 210 74-128105

Dichlorodifluoromethane 200 181 46-14590

Chloromethane 200 210 58-146105

Vinyl chloride 200 203 61-144101

Bromomethane 200 211 55-153105

12-Dibromo-3-Chloropropane 200 222 70-116111

12-Dichlorobenzene 200 209 82-122104

Trichlorofluoromethane 200 190 69-14795

11-Dichloroethene 200 223 56-139112

12-Dichloropropane 200 211 80-120106

112-Trichloro-122-trifluoroethane

200 203 47-139102

Acetone 200 250 45-156125

Carbon disulfide 200 218 58-139109

Methyl acetate 200 220 50-151110

Methylene Chloride 200 200 79-119100

trans-12-Dichloroethene 200 216 75-122108

Chlorodibromomethane 200 217 80-120109

Methyl tert-butyl ether 200 207 71-115104

Chloroethane 200 201 69-145101

11-Dichloroethane 200 204 78-122102

cis-12-Dichloroethene 200 211 80-120106

2-Butanone (MEK) 200 214 65-114107

Chloroform 200 205 82-123103

Ethylbenzene 200 206 79-126103

Cyclohexane 200 208 58-133104

Carbon tetrachloride 200 211 73-120105

Benzene 200 212 83-124106

12-Dichloroethane 200 204 74-118102

Trichloroethene 200 212 78-119106

Methylcyclohexane 200 215 61-129107

Dichlorobromomethane 200 214 79-119107

cis-13-Dichloropropene 200 216 80-120108

4-Methyl-2-pentanone (MIBK) 200 214 53-120107

Toluene 200 205 80-120103

trans-13-Dichloropropene 200 215 78-118108

112-Trichloroethane 200 217 79-119109

Tetrachloroethene 200 210 68-139105

2-Hexanone 200 201 53-121100

12-Dibromoethane 200 215 78-118107

Chlorobenzene 200 206 81-121103

Xylenes Total 600 612 76-121102

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 41 of 323

GCMS VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08977dWater

Lab ID LCS 460-1316563 Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

Styrene 200 207 69-112104

Bromoform 200 217 73-123109

Isopropylbenzene 200 207 80-125104

1122-Tetrachloroethane 200 210 74-126105

13-Dichlorobenzene 200 204 81-126102

14-Dichlorobenzene 200 204 83-123102

124-Trichlorobenzene 200 220 66-120110

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 42 of 323

GCMS VOA MATRIX SPIKE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08985dWater

Lab ID 460-45537-2 MS Client ID WC-17338-100512-MW101-MM-252 MS

TestAmerica Edison

LIMITS

COMPOUND

CONCENTRATION

REC

QC

REC

SAMPLE

CONCENTRATION

SPIKE

ADDED

(ugL) (ugL) (ugL)

MS MS

100 103 74-128111-Trichloroethane 1030060 U

100 865 46-145Dichlorodifluoromethane 87022 U

100 102 58-146Chloromethane 102010 U

100 104 61-144Vinyl chloride 104014 U

100 107 55-153Bromomethane 107018 U

100 121 70-11612-Dibromo-3-Chloropropane 121040 U F

100 107 82-12212-Dichlorobenzene 107021 U

100 121 69-147Trichlorofluoromethane 121015 U

100 108 56-13911-Dichloroethene 1080090 U

100 111 80-12012-Dichloropropane 1110090 U

100 102 47-139112-Trichloro-122-trifluoroethane

1020080 U

100 986 45-156Acetone 9927 U

100 113 58-139Carbon disulfide 113013 U

100 100 50-151Methyl acetate 100034 U

100 106 79-119Methylene Chloride 106018 U

100 106 75-122trans-12-Dichloroethene 106013 U

100 116 80-120Chlorodibromomethane 116020 U

100 114 71-115Methyl tert-butyl ether 114020 J

100 116 69-145Chloroethane 116017 U

100 104 78-12211-Dichloroethane 104013 U

100 105 80-120cis-12-Dichloroethene 105018 U

100 111 65-1142-Butanone (MEK) 11123 U

100 108 82-123Chloroform 1080080 U

100 107 79-126Ethylbenzene 107010 U

100 108 58-133Cyclohexane 108016 U

100 105 73-120Carbon tetrachloride 1050060 U

100 106 83-124Benzene 1060080 U

100 107 74-11812-Dichloroethane 107019 U

100 107 78-119Trichloroethene 1070090 U

100 115 61-129Methylcyclohexane 115014 U

100 113 79-119Dichlorobromomethane 113012 U

100 109 80-120cis-13-Dichloropropene 109018 U

100 111 53-1204-Methyl-2-pentanone (MIBK) 111099 U

100 106 80-120Toluene 106015 U

100 113 78-118trans-13-Dichloropropene 113024 U

100 112 79-119112-Trichloroethane 112019 U

100 110 68-139Tetrachloroethene 110010 U

100 109 53-1212-Hexanone 109050 U

100 116 78-11812-Dibromoethane 116028 U

100 107 81-121Chlorobenzene 107011 U

300 318 76-121Xylenes Total 106036 U

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 43 of 323

GCMS VOA MATRIX SPIKE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08985dWater

Lab ID 460-45537-2 MS Client ID WC-17338-100512-MW101-MM-252 MS

TestAmerica Edison

LIMITS

COMPOUND

CONCENTRATION

REC

QC

REC

SAMPLE

CONCENTRATION

SPIKE

ADDED

(ugL) (ugL) (ugL)

MS MS

100 107 69-112Styrene 107012 U

100 115 73-123Bromoform 115019 U

100 107 80-125Isopropylbenzene 1070080 U

100 115 74-1261122-Tetrachloroethane 115016 U

100 106 81-12613-Dichlorobenzene 106014 U

100 106 83-12314-Dichlorobenzene 106023 U

100 110 66-120124-Trichlorobenzene 110034 U

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 44 of 323

GCMS VOA MATRIX SPIKE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08986dWater

Lab ID 460-45537-2 MSD Client ID WC-17338-100512-MW101-MM-252

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

MSD MSD

100 106 30 74-128111-Trichloroethane 3106

100 896 30 46-145Dichlorodifluoromethane 490

100 101 30 58-146Chloromethane 0101

100 105 30 61-144Vinyl chloride 0105

100 105 30 55-153Bromomethane 2105

100 121 30 70-11612-Dibromo-3-Chloropropane 0121 F

100 111 30 82-12212-Dichlorobenzene 3111

100 997 30 69-147Trichlorofluoromethane 19100

100 119 30 56-13911-Dichloroethene 9119

100 110 30 80-12012-Dichloropropane 0110

100 111 30 47-139112-Trichloro-122-trifluoroethane

8111

100 101 30 45-156Acetone 2101

100 119 30 58-139Carbon disulfide 5119

100 101 30 50-151Methyl acetate 1101

100 106 30 79-119Methylene Chloride 0106

100 108 30 75-122trans-12-Dichloroethene 2108

100 118 30 80-120Chlorodibromomethane 2118

100 116 30 71-115Methyl tert-butyl ether 1116 F

100 105 30 69-145Chloroethane 10105

100 111 30 78-12211-Dichloroethane 7111

100 109 30 80-120cis-12-Dichloroethene 4109

100 114 30 65-1142-Butanone (MEK) 3114

100 113 30 82-123Chloroform 4113

100 111 30 79-126Ethylbenzene 3111

100 117 30 58-133Cyclohexane 7117

100 110 30 73-120Carbon tetrachloride 5110

100 114 30 83-124Benzene 7114

100 109 30 74-11812-Dichloroethane 2109

100 113 30 78-119Trichloroethene 5113

100 121 30 61-129Methylcyclohexane 5121

100 116 30 79-119Dichlorobromomethane 3116

100 115 30 80-120cis-13-Dichloropropene 5115

100 114 30 53-1204-Methyl-2-pentanone (MIBK) 3114

100 111 30 80-120Toluene 5111

100 119 30 78-118trans-13-Dichloropropene 5119 F

100 116 30 79-119112-Trichloroethane 3116

100 116 30 68-139Tetrachloroethene 5116

100 111 30 53-1212-Hexanone 2111

100 117 30 78-11812-Dibromoethane 1117

100 111 30 81-121Chlorobenzene 3111

300 329 30 76-121Xylenes Total 3110

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 45 of 323

GCMS VOA MATRIX SPIKE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08986dWater

Lab ID 460-45537-2 MSD Client ID WC-17338-100512-MW101-MM-252

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

MSD MSD

100 110 30 69-112Styrene 3110

100 114 30 73-123Bromoform 1114

100 111 30 80-125Isopropylbenzene 4111

100 116 30 74-1261122-Tetrachloroethane 0116

100 110 30 81-12613-Dichlorobenzene 4110

100 110 30 83-12314-Dichlorobenzene 4110

100 119 30 66-120124-Trichlorobenzene 8119

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 46 of 323

FORM IV

GCMS VOA METHOD BLANK SUMMARY

Lab Name

SDG No

Job No 460-45537-1TestAmerica Edison

Date Analyzed

GC Column ID

Instrument ID 10112012 2247

Rtx-VMS

NHeated Purge(YN)

VOAMS5

e08981dLab File ID Lab Sample ID MB 460-1316564

WaterMatrix

018(mm)

THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES

LAB SAMPLE ID

LAB

FILE ID DATE ANALYZEDCLIENT SAMPLE ID

10112012 2113e08977dLCS 460-1316563

10112012 2317e08982d460-45537-3TB-17338-100512-253

10112012 2341e08983d460-45537-1WC-17338-100512-MW14-MM-251

10122012 0004e08984d460-45537-2WC-17338-100512-MW101-MM-252

10122012 0027e08985d460-45537-2 MSWC-17338-100512-MW101-MM-252 MS

10122012 0051e08986d460-45537-2 MSDWC-17338-100512-MW101-MM-252 MSD

FORM IV 8260B

10162012Page 47 of 323

FORM V

BROMOFLUOROBENZENE (BFB)

Lab Name

SDG No

Job No 460-45537-1

Lab File ID

Instrument ID

e07834d

VOAMS5

09172012

0324

BFB Injection Date

BFB Injection Time

ME ION ABUNDANCE CRITERIA RELATIVEABUNDANCE

Analysis Batch No 128076

50 150 - 400 of mass 95 219

75 300 - 600 of mass 95 525

95 Base Peak 100 relative abundance 1000

96 50 - 90 of mass 95 64

173 Less than 20 of mass 174 00 (00)1

174 500 - 12000 of mass 95 796

175 50 - 90 of mass 174 66 (83)1

176 950 - 1010 of mass 174 761 (957)1

177 50 - 90 of mass 176 48 (63)2

1-Value is mass 174 2-Value is mass 176

THIS CHECK APPLIES TO THE FOLLOWING SAMPLES MS MSD BLANKS AND STANDARDS

GCMS VOA INSTRUMENT PERFORMANCE CHECK

TestAmerica Edison

CLIENT SAMPLE IDLAB

FILE IDLAB SAMPLE IDDATE

ANALYZEDTIME

ANALYZED

e07836d 09172012 0449IC 460-1280762

e07838d 09172012 0536IC 460-1280763

e07839d 09172012 0600ICIS 460-1280764

e07840d 09172012 0623IC 460-1280765

e07841d 09172012 0646IC 460-1280766

e07842d 09172012 0710IC 460-1280767

FORM V 8260B 10162012Page 48 of 323

FORM V

BROMOFLUOROBENZENE (BFB)

Lab Name

SDG No

Job No 460-45537-1

Lab File ID

Instrument ID

e08975d

VOAMS5

10112012

2008

BFB Injection Date

BFB Injection Time

ME ION ABUNDANCE CRITERIA RELATIVEABUNDANCE

Analysis Batch No 131656

50 150 - 400 of mass 95 218

75 300 - 600 of mass 95 518

95 Base Peak 100 relative abundance 1000

96 50 - 90 of mass 95 65

173 Less than 20 of mass 174 07 (07)1

174 500 - 12000 of mass 95 896

175 50 - 90 of mass 174 72 (80)1

176 950 - 1010 of mass 174 872 (973)1

177 50 - 90 of mass 176 53 (61)2

1-Value is mass 174 2-Value is mass 176

THIS CHECK APPLIES TO THE FOLLOWING SAMPLES MS MSD BLANKS AND STANDARDS

GCMS VOA INSTRUMENT PERFORMANCE CHECK

TestAmerica Edison

CLIENT SAMPLE IDLAB

FILE IDLAB SAMPLE IDDATE

ANALYZEDTIME

ANALYZED

e08976d 10112012 2050CCVIS 460-1316562

e08977d 10112012 2113LCS 460-1316563

e08981d 10112012 2247MB 460-1316564

TB-17338-100512-253 e08982d 10112012 2317460-45537-3

WC-17338-100512-MW14-MM-251

e08983d 10112012 2341460-45537-1

WC-17338-100512-MW101-MM-252

e08984d 10122012 0004460-45537-2

WC-17338-100512-MW101-MM-252 MS

e08985d 10122012 0027460-45537-2 MS

WC-17338-100512-MW101-MM-252 MSD

e08986d 10122012 0051460-45537-2 MSD

e08987d 10122012 0114CCV 460-13165610

FORM V 8260B 10162012Page 49 of 323

GCMS VOA INTERNAL STANDARD AREA AND RETENTION TIME SUMMARY

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVIS 460-1316562 Date Analyzed 10112012 2050

Lab File ID (Standard) e08976d

Instrument ID VOAMS5 GC Column Rtx-VMS ID 018(mm)

Heated Purge (YN) N

Calibration ID 17515

AREA RT AREA RT AREA RT

FB CBZ DCB

UPPER LIMIT

LOWER LIMIT

2625312

656328 578671

2314682

333917

1335668

360 695 10471224 HOUR STD

410

310

745

645

1097

997

1312656 1157341 667834

LAB SAMPLE ID CLIENT SAMPLE ID

LCS 460-1316563 1318918 1146590 683882 360 695 1047

MB 460-1316564 1238441 1084553 638826 360 695 1047

460-45537-3 TB-17338-100512-253 1280000 1135339 646856 359 695 1047

460-45537-1 WC-17338-100512-MW14-MM-251

1242225 1119807 641810 359 695 1047

460-45537-2 WC-17338-100512-MW101-MM-252

1247617 1105330 633816 360 695 1047

460-45537-2 MS WC-17338-100512-MW101-MM-252 MS

1234975 1102789 642491 359 695 1047

460-45537-2 MSD WC-17338-100512-MW101-MM-252 MSD

1296388 1119645 654839 360 695 1047

CCV 460-13165610 1274024 1125053 665092 359 695 1047

FB = Fluorobenzene

CBZ = Chlorobenzene-d5

DCB = 14-Dichlorobenzene-d4

Area Limit = 50-200 of internal standard area

RT Limit = plusmn 05 minutes of internal standard RT

Column used to flag values outside QC limits

FORM VIII 8260B

10162012Page 50 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014J1634-04-4 Methyl tert-butyl ether 017

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015J108-88-3 Toluene 017

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 51 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010J127-18-4 Tetrachloroethene 028

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

96 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 52 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 53 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08983d Report Date 12-Oct-2012 0041

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08983dLab Smp Id 460-45537-A-1 Client Smp ID WC-17338-100512-MW1Inj Date 11-OCT-2012 2341 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-1Misc Info 460-45537-A-1Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 8 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

28 MTBE 73 2016 2022 (0561) 2797 016909 017(a)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 375883 486598 49

52 Fluorobenzene 96 3595 3601 (1000) 1242225 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1240232 479413 48

66 Toluene 91 5162 5162 (0742) 4639 017041 017(a)

71 Tetrachloroethene 166 5582 5582 (0803) 1902 028047 028(a)

78 Chlorobenzene-d5 117 6954 6954 (1000) 1119807 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 516081 495668 50

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 641810 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 54 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

10162012Page 55 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

28 MTBE

10162012Page 56 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

66 Toluene

10162012Page 57 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

71 Tetrachloroethene

10162012Page 58 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014J1634-04-4 Methyl tert-butyl ether 020

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 59 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

98 70-130460-00-4 4-Bromofluorobenzene

97 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 60 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 61 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08984d Report Date 12-Oct-2012 1126

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08984dLab Smp Id 460-45537-A-2 Client Smp ID WC-17338-100512-MW1Inj Date 12-OCT-2012 0004 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-2Misc Info 460-45537-A-2Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 9 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

28 MTBE 73 2016 2022 (0561) 3378 020333 020(a)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 375158 483561 48

52 Fluorobenzene 96 3595 3601 (1000) 1247617 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1243750 487069 49

78 Chlorobenzene-d5 117 6954 6954 (1000) 1105330 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 506189 492299 49

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 633816 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 62 of 323

Data File e08984d

Date 12-OCT-2012 0004

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-2 Operator GCMS VOAMS5

10162012Page 63 of 323

Data File e08984d

Date 12-OCT-2012 0004

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-2 Operator GCMS VOAMS5

28 MTBE

10162012Page 64 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018J75-09-2 Methylene Chloride 074

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014U1634-04-4 Methyl tert-butyl ether 014

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080J67-66-3 Chloroform 0096

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 65 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

97 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 66 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 67 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08982d Report Date 12-Oct-2012 1126

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08982dLab Smp Id 460-45537-A-3 Client Smp ID TB-17338-100512-253Inj Date 11-OCT-2012 2317 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-3Misc Info 460-45537-A-3Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 7 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

22 Methylene Chloride 49 1864 1864 (0518) 6426 073512 074(a)

42 Chloroform 83 2839 2845 (0790) 973 009557 0096(aH)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 385354 484137 48

52 Fluorobenzene 96 3595 3601 (1000) 1280000 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1266759 482968 48

78 Chlorobenzene-d5 117 6954 6954 (1000) 1135339 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 518232 493851 49

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 646856 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

H - Operator selected an alternate compound hit

10162012Page 68 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

10162012Page 69 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

22 Methylene Chloride

10162012Page 70 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

42 Chloroform

10162012Page 71 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1280762 e07836d2Level IC 460-1280763 e07838d3Level ICIS 460-1280764 e07839d4Level IC 460-1280765 e07840d5Level IC 460-1280766 e07841d6Level IC 460-1280767 e07842d

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

Dichlorodifluoromethane 01877 01710 01761 01874 01774 Ave 6501572

01000 30001761

Chloromethane 04585 03624 03717 03896 03503 Ave 13403074

01000 30003733

Vinyl chloride 03440 02904 02965 03157 02914 Ave 10102532

01000 30002985

Bromomethane 01457 01433 01250 01279 01268 Ave 8301184

01000 30001312

Chloroethane 01177 01273 01133 01184 00992 Ave 14300838

01000 30001099

Trichlorofluoromethane 02861 02160 02403 02359 02461 Ave 9902285

01000 30002422

11-Dichloroethene 01607 01355 01549 01479 01528 Ave 5801456

01000 30001496

Carbon disulfide 07031 06470 06825 07347 07283 Ave 5906366

01000 30006887

112-Trichloro-122-trifluoroethane 01346 01631 01661 01849 01887 Ave 11601772

01000 30001691

Methylene Chloride 04479 03769 03581 03500 03182 Ave 14802947

01000 30003576

Acetone 00225 00193 00188 00182 00162 Ave 13800153

01000 30000184

trans-12-Dichloroethene 02047 01989 02141 02174 02016 Ave 4301946

01000 30002052

Methyl acetate 00482 00463 00420 00421 00402 Ave 9400371

01000 30000426

Methyl tert-butyl ether 07109 07281 06924 06817 06907 Ave 6505992

01000 30006838

11-Dichloroethane 04650 04524 04893 04673 04494 Ave 4604257

01000 30004582

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 72 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

cis-12-Dichloroethene 02536 02396 02453 02363 02237 Ave 5602184

01000 30002361

Cyclohexane 03116 04199 04030 04447 04640 Ave 13204438

01000 30004145

Chloroform 03895 04109 04030 04060 03948 Ave 2503851

01000 30003982

Carbon tetrachloride 02420 02373 02793 02813 02930 Ave 9102903

01000 30002705

111-Trichloroethane 03091 03114 03513 03424 03583 Ave 6403522

01000 30003375

2-Butanone (MEK) 00273 00279 00385 00372 00372 Ave 14900364

01000 30000341

Benzene 12012 12533 12592 12117 12284 Ave 8709836

01000 30011896

12-Dichloroethane 03398 03425 03293 03270 03193 Ave 3503124

01000 30003284

Methylcyclohexane 02272 03440 03287 03727 03690 Ave 16303532

01000 30003325

Trichloroethene 02571 02192 02414 02341 02365 Ave 5202426

01000 30002385

12-Dichloropropane 02758 02786 02804 02730 02724 Ave 1202733

01000 30002756

Dichlorobromomethane 03209 03160 03185 03141 03239 Ave 1303237

01000 30003195

cis-13-Dichloropropene 05043 05293 05370 05217 05393 Ave 3105530

01000 30005308

Toluene 13662 13454 14250 13844 13425 Ave 9510731

01000 30013228

Tetrachloroethene 02730 02844 03369 03253 03225 Ave 8303255

01000 30003113

4-Methyl-2-pentanone (MIBK) 03587 03603 03526 03550 03603 Ave 1603692

01000 30003593

trans-13-Dichloropropene 04563 04743 04806 04779 04910 Ave 3805114

01000 30004819

112-Trichloroethane 02303 02327 02287 02201 02185 Ave 2502280

01000 30002264

Chlorodibromomethane 03013 02986 03088 03052 03111 Ave 3003249

01000 30003083

12-Dibromoethane 02596 02708 02743 02671 02629 Ave 2002676

01000 30002670

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 73 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

2-Hexanone 02652 02737 02670 02679 02755 Ave 3202514

01000 30002668

Chlorobenzene 08958 08985 09292 09070 08727 Ave 4008261

01000 30008882

Ethylbenzene 04549 04523 04953 04866 04834 Ave 3704808

01000 30004756

m-Xylene amp p-Xylene 05967 05752 06297 06168 06094 Ave 6505224

01000 30005917

o-Xylene 05732 05675 06142 06014 05989 Ave 3205765

01000 30005886

Bromoform 02053 01991 02150 02194 02258 Ave 4902237

01000 30002147

Styrene 09657 09899 10525 10511 10477 Ave 6408917

01000 30009998

Isopropylbenzene 13314 13509 15606 15346 15340 Ave 10811764

01000 30014146

1122-Tetrachloroethane 06545 06405 06616 06489 06390 Ave 1706330

01000 30006462

13-Dichlorobenzene 12616 12687 13292 13133 12758 Ave 3012242

01000 30012788

14-Dichlorobenzene 13636 13114 13708 13534 13010 Ave 3412550

01000 30013259

12-Dichlorobenzene 12298 12143 12601 12232 11746 Ave 3211521

01000 30012090

12-Dibromo-3-Chloropropane 01290 01163 01082 01109 01042 Ave 7801095

01000 30001130

124-Trichlorobenzene 06538 06139 06311 06265 05725 Ave 5405732

01000 30006118

12-Dichloroethane-d4 (Surr) 02599 02736 02573 02553 02667 Ave 2802702

01000 30002638

Toluene-d8 (Surr) 11377 12027 11720 11573 11645 Ave 1811690

01000 30011672

4-Bromofluorobenzene 07799 08146 08086 08044 08193 Ave 1908206

01000 30008079

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 74 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1280762 e07836dLevel 2 IC 460-1280763 e07838dLevel 3 ICIS 460-1280764 e07839dLevel 4 IC 460-1280765 e07840dLevel 5 IC 460-1280766 e07841dLevel 6 IC 460-1280767 e07842d

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Dichlorodifluoromethane AveFB 8660 39416 167418 450014 17982634551928

100 500 200 500 200500

Chloromethane AveFB 21155 83523 353287 935453 35519068902969

100 500 200 500 200500

Vinyl chloride AveFB 15876 66919 281874 757876 29543837332518

100 500 200 500 200500

Bromomethane AveFB 6723 33032 118799 307121 12855673429373

100 500 200 500 200500

Chloroethane AveFB 5433 29332 107678 284219 10059762426216

100 500 200 500 200500

Trichlorofluoromethane AveFB 13203 49780 228376 566305 24953266618134

100 500 200 500 200500

11-Dichloroethene AveFB 7415 31234 147259 355088 15491024214942

100 500 200 500 200500

Carbon disulfide AveFB 32446 149121 648801 1763903 738404918433408

100 500 200 500 200500

112-Trichloro-122-trifluoroethane

AveFB 6213 37580 157867 443949 19130255130629

100 500 200 500 200500

Methylene Chloride AveFB 20667 86862 340378 840419 32256318533685

100 500 200 500 200500

Acetone AveFB 5188 13342 17849 43750 164598441742

500 150 200 500 200500

trans-12-Dichloroethene AveFB 9445 45844 203500 521911 20443355633771

100 500 200 500 200500

Methyl acetate AveFB 2222 10660 39926 101112 4077131074355

100 500 200 500 200500

Methyl tert-butyl ether AveFB 32806 167790 658123 1636664 700252217351574

100 500 200 500 200500

11-Dichloroethane AveFB 21457 104265 465144 1121930 455634112326764

100 500 200 500 200500

cis-12-Dichloroethene AveFB 11702 55218 233129 567238 22679686324299

100 500 200 500 200500

FORM VI 8260B 10162012Page 75 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Cyclohexane AveFB 14380 96765 383104 1067735 470410312852489

100 500 200 500 200500

Chloroform AveFB 17974 94697 383084 974788 400250611152231

100 500 200 500 200500

Carbon tetrachloride AveFB 11168 54679 265527 675330 29705928405131

100 500 200 500 200500

111-Trichloroethane AveFB 14264 71766 333961 821993 363312510199723

100 500 200 500 200500

2-Butanone (MEK) AveFB 6291 19260 36552 89217 3773171055008

500 150 200 500 200500

Benzene AveCBZ 45050 227079 968083 2380099 986355721876514

100 500 200 500 200500

12-Dichloroethane AveFB 15679 78926 312991 785178 32368389046377

100 500 200 500 200500

Methylcyclohexane AveFB 10486 79279 312424 894738 374094710227785

100 500 200 500 200500

Trichloroethene AveFB 11865 50527 229465 562086 23978387026524

100 500 200 500 200500

12-Dichloropropane AveFB 12728 64209 266559 655380 27621167913672

100 500 200 500 200500

Dichlorobromomethane AveFB 14807 72835 302742 754124 32836079374106

100 500 200 500 200500

cis-13-Dichloropropene AveCBZ 18914 95905 412847 1024782 433022112299317

100 500 200 500 200500

Toluene AveCBZ 51238 243768 1095520 2719268 1077972123868197

100 500 200 500 200500

Tetrachloroethene AveCBZ 10238 51530 258990 639002 25895417239654

100 500 200 500 200500

4-Methyl-2-pentanone (MIBK) AveCBZ 67258 195851 271059 697282 28927468212153

500 150 200 500 200500

trans-13-Dichloropropene AveCBZ 17115 85943 369516 938808 394242511373599

100 500 200 500 200500

112-Trichloroethane AveCBZ 8636 42154 175853 432262 17543015071317

100 500 200 500 200500

Chlorodibromomethane AveCBZ 11301 54107 237421 599464 24982697227226

100 500 200 500 200500

12-Dibromoethane AveCBZ 9735 49066 210900 524614 21107665952425

100 500 200 500 200500

2-Hexanone AveCBZ 49729 148758 205286 526223 22117155590902

500 150 200 500 200500

Chlorobenzene AveCBZ 33596 162793 714336 1781568 700752018374405

100 500 200 500 200500

FORM VI 8260B 10162012Page 76 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Ethylbenzene AveCBZ 17061 81955 380762 955894 388164310693410

100 500 200 500 200500

m-Xylene amp p-Xylene AveCBZ 44761 208423 968280 2423002 978688223238078

200 100 400 100 4001000

o-Xylene AveCBZ 21499 102832 472158 1181273 480921512821590

100 500 200 500 200500

Bromoform AveCBZ 7698 36074 165267 430943 18127954974461

100 500 200 500 200500

Styrene AveCBZ 36217 179367 809158 2064560 841264519831782

100 500 200 500 200500

Isopropylbenzene AveCBZ 49933 244766 1199765 3014281 1231710326165908

100 500 200 500 200500

1122-Tetrachloroethane AveDCB 13823 63947 277413 702309 28987687365342

100 500 200 500 200500

13-Dichlorobenzene AveDCB 26644 126663 557342 1421450 578731414243841

100 500 200 500 200500

14-Dichlorobenzene AveDCB 28798 130929 574816 1464915 590189114602396

100 500 200 500 200500

12-Dichlorobenzene AveDCB 25972 121236 528396 1324016 532862113405399

100 500 200 500 200500

12-Dibromo-3-Chloropropane AveDCB 2725 11615 45388 120062 4727441274610

100 500 200 500 200500

124-Trichlorobenzene AveDCB 13808 61295 264648 678119 25969596669727

100 500 200 500 200500

12-Dichloroethane-d4 (Surr) AveFB 599539 630441 611357 613057 676105782507

500 500 500 500 500500

Toluene-d8 (Surr) AveCBZ 2133452 2179204 2252606 2273339 23375152600040

500 500 500 500 500500

4-Bromofluorobenzene AveDCB 823604 813301 847619 870646 929176954872

500 500 500 500 500500

Curve Type LegendAve = Average ISTD

FORM VI 8260B 10162012Page 77 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07836d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07836dLab Smp Id IC-VMCAL1 Inj Date 17-SEP-2012 0449 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL1Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 2 Calibration Sample Level 1Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 8660 100000 11

3 Chloromethane 50 1004 1004 (0280) 21155 100000 12

4 Vinyl Chloride 62 1016 1016 (0283) 15876 100000 12

6 Bromomethane 94 1169 1169 (0326) 6723 100000 11

5 Chloroethane 64 1230 1230 (0343) 5433 100000 11

7 Trichlorofluoromethane 101 1291 1291 (0360) 13203 100000 12

14 Freon TF 101 1565 1565 (0436) 6213 100000 080(a)

15 11-Dichloroethene 96 1547 1547 (0431) 7415 100000 11

16 Acetone 58 1882 1882 (0524) 5188 500000 61

18 Carbon Disulfide 76 1559 1559 (0434) 32446 100000 10

27 Methyl Acetate 74 1955 1955 (0545) 2222 100000 11

22 Methylene Chloride 49 1851 1851 (0516) 20667 100000 12

28 MTBE 73 2016 2016 (0562) 32806 100000 10

25 trans-12-Dichloroethene 96 1937 1937 (0540) 9445 100000 100

30 11-Dichloroethane 63 2303 2303 (0642) 21457 100000 10

36 cis-12-Dichloroethene 96 2644 2644 (0737) 11702 100000 11

10162012Page 78 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07836d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0856) 6291 500000 40(a)

42 Chloroform 83 2839 2839 (0791) 17974 100000 098(a)

44 Cyclohexane 56 2778 2778 (0774) 14380 100000 075(a)

43 111-Trichloroethane 97 2973 2973 (0828) 14264 100000 092(a)

45 Carbon Tetrachloride 117 2924 2924 (0815) 11168 100000 089(a)

48 Benzene 78 3254 3254 (0468) 45050 100000 10

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 599539 500000 49

49 12-Dichloroethane 62 3412 3412 (0951) 15679 100000 10

52 Fluorobenzene 96 3589 3589 (1000) 2307227 500000

54 Trichloroethene 95 3735 3735 (1041) 11865 100000 11

56 Methyl cyclohexane 83 3723 3723 (1037) 10486 100000 068(a)

57 12-Dichloropropane 63 4192 4192 (1168) 12728 100000 10

68 Bromodichloromethane 83 4266 4266 (1189) 14807 100000 10

67 cis-13-Dichloropropene 75 4906 4906 (0706) 18914 100000 095(a)

70 4-Methyl-2-Pentanone 43 5625 5625 (0810) 67258 500000 50

$ 65 Toluene-d8 (SUR) 98 5101 5101 (0734) 2133452 500000 49

66 Toluene 91 5156 5156 (0742) 51238 100000 10

64 trans-13-Dichloropropene 75 5650 5650 (0813) 17115 100000 095(a)

69 112-Trichloroethane 83 5826 5826 (0839) 8636 100000 10

71 Tetrachloroethene 166 5582 5582 (0803) 10238 100000 088(a)

73 2-Hexanone 43 6674 6674 (0960) 49729 500000 50

74 Dibromochloromethane 129 6015 6015 (0866) 11301 100000 098(a)

77 12-Dibromoethane 107 6265 6265 (0902) 9735 100000 097(a)

78 Chlorobenzene-d5 117 6948 6948 (1000) 1875221 500000

79 Chlorobenzene 112 6972 6972 (1004) 33596 100000 10

81 Ethylbenzene 106 7064 7064 (1017) 17061 100000 096(a)

82 m+p-Xylene 106 7271 7271 (1046) 44761 200000 20

84 o-Xylene 106 7856 7856 (1131) 21499 100000 097(a)

85 Styrene 104 7942 7942 (1143) 36217 100000 096(a)

86 Bromoform 173 7911 7911 (1139) 7698 100000 096(a)

88 Isopropylbenzene 105 8344 8344 (1201) 49933 100000 094(a)

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 823604 500000 48

92 1122-Tetrachloroethane 83 9112 9112 (0871) 13823 100000 10

105 13-Dichlorobenzene 146 10332 10332 (0987) 26644 100000 099(a)

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1055978 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 28798 100000 10

111 12-Dichlorobenzene 146 11148 11148 (1065) 25972 100000 10(H)

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 2725 100000 11

114 124-Trichlorobenzene 180 12971 12971 (1239) 13808 100000 11

M 120 12-Dichloroethene (Total) 100 21147 200000 21

M 121 Xylene (Total) 100 66260 300000 30

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

H - Operator selected an alternate compound hit

10162012Page 79 of 323

Data File e07836d

Date 17-SEP-2012 0449

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL1 Operator GCMS VOAMS5

10162012Page 80 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07838d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07838dLab Smp Id IC-VMCAL2 Inj Date 17-SEP-2012 0536 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL2Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 4 Calibration Sample Level 2Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 39416 500000 48

3 Chloromethane 50 1016 1016 (0283) 83523 500000 48

4 Vinyl Chloride 62 1022 1022 (0285) 66919 500000 49

6 Bromomethane 94 1169 1169 (0326) 33032 500000 55

5 Chloroethane 64 1230 1230 (0343) 29332 500000 58

7 Trichlorofluoromethane 101 1291 1291 (0360) 49780 500000 45

14 Freon TF 101 1559 1559 (0434) 37580 500000 48

15 11-Dichloroethene 96 1541 1541 (0429) 31234 500000 45

16 Acetone 58 1894 1894 (0528) 13342 150000 16

18 Carbon Disulfide 76 1553 1553 (0433) 149121 500000 47

27 Methyl Acetate 74 1961 1961 (0546) 10660 500000 54

22 Methylene Chloride 49 1851 1851 (0516) 86862 500000 53

28 MTBE 73 2016 2016 (0562) 167790 500000 53

25 trans-12-Dichloroethene 96 1937 1937 (0540) 45844 500000 48

30 11-Dichloroethane 63 2296 2296 (0640) 104265 500000 49

36 cis-12-Dichloroethene 96 2644 2644 (0737) 55218 500000 51

10162012Page 81 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07838d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0857) 19260 150000 12

42 Chloroform 83 2839 2839 (0791) 94697 500000 52

44 Cyclohexane 56 2772 2772 (0772) 96765 500000 51

43 111-Trichloroethane 97 2973 2973 (0828) 71766 500000 46

45 Carbon Tetrachloride 117 2924 2924 (0815) 54679 500000 44

48 Benzene 78 3254 3254 (0468) 227079 500000 53

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 630441 500000 52

49 12-Dichloroethane 62 3412 3412 (0951) 78926 500000 52

52 Fluorobenzene 96 3589 3589 (1000) 2304638 500000

54 Trichloroethene 95 3735 3735 (1041) 50527 500000 46

56 Methyl cyclohexane 83 3717 3717 (1036) 79279 500000 52

57 12-Dichloropropane 63 4192 4192 (1168) 64209 500000 50

68 Bromodichloromethane 83 4272 4272 (1190) 72835 500000 49

67 cis-13-Dichloropropene 75 4906 4906 (0706) 95905 500000 50

70 4-Methyl-2-Pentanone 43 5625 5625 (0810) 195851 150000 15

$ 65 Toluene-d8 (SUR) 98 5101 5101 (0734) 2179204 500000 52

66 Toluene 91 5156 5156 (0742) 243768 500000 51

64 trans-13-Dichloropropene 75 5643 5643 (0812) 85943 500000 49

69 112-Trichloroethane 83 5820 5820 (0838) 42154 500000 51

71 Tetrachloroethene 166 5576 5576 (0803) 51530 500000 46

73 2-Hexanone 43 6680 6680 (0961) 148758 150000 15

74 Dibromochloromethane 129 6015 6015 (0866) 54107 500000 48

77 12-Dibromoethane 107 6259 6259 (0901) 49066 500000 51

78 Chlorobenzene-d5 117 6948 6948 (1000) 1811885 500000

79 Chlorobenzene 112 6972 6972 (1004) 162793 500000 50

81 Ethylbenzene 106 7058 7058 (1016) 81955 500000 48

82 m+p-Xylene 106 7271 7271 (1046) 208423 100000 97

84 o-Xylene 106 7856 7856 (1131) 102832 500000 48

85 Styrene 104 7942 7942 (1143) 179367 500000 50

86 Bromoform 173 7911 7911 (1139) 36074 500000 46

88 Isopropylbenzene 105 8344 8344 (1201) 244766 500000 48

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 813301 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 63947 500000 50

105 13-Dichlorobenzene 146 10325 10325 (0987) 126663 500000 50

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 998386 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 130929 500000 49

111 12-Dichlorobenzene 146 11148 11148 (1065) 121236 500000 50

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 11615 500000 51

114 124-Trichlorobenzene 180 12965 12965 (1239) 61295 500000 50

M 120 12-Dichloroethene (Total) 100 101062 100000 99

M 121 Xylene (Total) 100 311255 150000 14

10162012Page 82 of 323

Data File e07838d

Date 17-SEP-2012 0536

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL2 Operator GCMS VOAMS5

10162012Page 83 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07839d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07839dLab Smp Id ICIS-VMCAL3 Inj Date 17-SEP-2012 0600 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info ICIS-VMCAL3Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 5 Calibration Sample Level 3Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 167418 200000 20

3 Chloromethane 50 1016 1016 (0283) 353287 200000 20

4 Vinyl Chloride 62 1016 1016 (0283) 281874 200000 20

6 Bromomethane 94 1175 1175 (0327) 118799 200000 19

5 Chloroethane 64 1230 1230 (0343) 107678 200000 21

7 Trichlorofluoromethane 101 1291 1291 (0360) 228376 200000 20

14 Freon TF 101 1559 1559 (0434) 157867 200000 20

15 11-Dichloroethene 96 1540 1540 (0429) 147259 200000 21

16 Acetone 58 1888 1888 (0526) 17849 200000 20

18 Carbon Disulfide 76 1559 1559 (0434) 648801 200000 20

27 Methyl Acetate 74 1955 1955 (0545) 39926 200000 20

22 Methylene Chloride 49 1851 1851 (0516) 340378 200000 20

28 MTBE 73 2016 2016 (0562) 658123 200000 20

25 trans-12-Dichloroethene 96 1943 1943 (0541) 203500 200000 21

30 11-Dichloroethane 63 2303 2303 (0642) 465144 200000 21

36 cis-12-Dichloroethene 96 2644 2644 (0737) 233129 200000 21

10162012Page 84 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07839d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0856) 36552 200000 22

42 Chloroform 83 2839 2839 (0791) 383084 200000 20

44 Cyclohexane 56 2778 2778 (0774) 383104 200000 19

43 111-Trichloroethane 97 2973 2973 (0828) 333961 200000 21

45 Carbon Tetrachloride 117 2924 2924 (0815) 265527 200000 21

48 Benzene 78 3254 3254 (0468) 968083 200000 21

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 611357 500000 49

49 12-Dichloroethane 62 3412 3412 (0951) 312991 200000 20

52 Fluorobenzene 96 3589 3589 (1000) 2376396 500000

54 Trichloroethene 95 3735 3735 (1041) 229465 200000 20

56 Methyl cyclohexane 83 3723 3723 (1037) 312424 200000 20

57 12-Dichloropropane 63 4192 4192 (1168) 266559 200000 20

68 Bromodichloromethane 83 4266 4266 (1189) 302742 200000 20

67 cis-13-Dichloropropene 75 4906 4906 (0705) 412847 200000 20

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 271059 200000 20

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2252606 500000 50

66 Toluene 91 5156 5156 (0741) 1095520 200000 22

64 trans-13-Dichloropropene 75 5643 5643 (0812) 369516 200000 20

69 112-Trichloroethane 83 5820 5820 (0837) 175853 200000 20

71 Tetrachloroethene 166 5576 5576 (0802) 258990 200000 22

73 2-Hexanone 43 6680 6680 (0961) 205286 200000 20

74 Dibromochloromethane 129 6015 6015 (0865) 237421 200000 20

77 12-Dibromoethane 107 6259 6259 (0900) 210900 200000 20

78 Chlorobenzene-d5 117 6954 6954 (1000) 1921967 500000

79 Chlorobenzene 112 6972 6972 (1003) 714336 200000 21

81 Ethylbenzene 106 7064 7064 (1016) 380762 200000 21

82 m+p-Xylene 106 7277 7277 (1046) 968280 400000 42

84 o-Xylene 106 7856 7856 (1130) 472158 200000 21

85 Styrene 104 7942 7942 (1142) 809158 200000 21

86 Bromoform 173 7911 7911 (1138) 165267 200000 20

88 Isopropylbenzene 105 8344 8344 (1200) 1199765 200000 22

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 847619 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 277413 200000 20

105 13-Dichlorobenzene 146 10325 10325 (0987) 557342 200000 21

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1048295 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 574816 200000 21

111 12-Dichlorobenzene 146 11148 11148 (1065) 528396 200000 21

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 45388 200000 19

114 124-Trichlorobenzene 180 12965 12965 (1239) 264648 200000 21

M 120 12-Dichloroethene (Total) 100 436629 400000 42

M 121 Xylene (Total) 100 1440438 600000 63

10162012Page 85 of 323

Data File e07839d

Date 17-SEP-2012 0600

Client ID Instrument VOAMS5i

Sample Info ICIS-VMCAL3 Operator GCMS VOAMS5

10162012Page 86 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07840d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07840dLab Smp Id IC-VMCAL4 Inj Date 17-SEP-2012 0623 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL4Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 6 Calibration Sample Level 4Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 450014 500000 53

3 Chloromethane 50 1010 1010 (0281) 935453 500000 52

4 Vinyl Chloride 62 1016 1016 (0283) 757876 500000 53

6 Bromomethane 94 1175 1175 (0327) 307121 500000 49

5 Chloroethane 64 1230 1230 (0342) 284219 500000 54

7 Trichlorofluoromethane 101 1290 1290 (0359) 566305 500000 49

14 Freon TF 101 1565 1565 (0435) 443949 500000 55

15 11-Dichloroethene 96 1540 1540 (0428) 355088 500000 49

16 Acetone 58 1888 1888 (0525) 43750 500000 50

18 Carbon Disulfide 76 1559 1559 (0434) 1763903 500000 53

27 Methyl Acetate 74 1961 1961 (0546) 101112 500000 49

22 Methylene Chloride 49 1851 1851 (0515) 840419 500000 49

28 MTBE 73 2016 2016 (0561) 1636664 500000 50

25 trans-12-Dichloroethene 96 1943 1943 (0540) 521911 500000 53

30 11-Dichloroethane 63 2302 2302 (0640) 1121930 500000 51

36 cis-12-Dichloroethene 96 2644 2644 (0735) 567238 500000 50

10162012Page 87 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07840d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0854) 89217 500000 54

42 Chloroform 83 2839 2839 (0790) 974788 500000 51

44 Cyclohexane 56 2778 2778 (0773) 1067735 500000 54

43 111-Trichloroethane 97 2973 2973 (0827) 821993 500000 51

45 Carbon Tetrachloride 117 2924 2924 (0813) 675330 500000 52

48 Benzene 78 3254 3254 (0468) 2380099 500000 51

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0934) 613057 500000 48

49 12-Dichloroethane 62 3412 3412 (0949) 785178 500000 50

52 Fluorobenzene 96 3595 3595 (1000) 2400971 500000

54 Trichloroethene 95 3735 3735 (1039) 562086 500000 49

56 Methyl cyclohexane 83 3723 3723 (1036) 894738 500000 56

57 12-Dichloropropane 63 4192 4192 (1166) 655380 500000 50

68 Bromodichloromethane 83 4272 4272 (1188) 754124 500000 49

67 cis-13-Dichloropropene 75 4906 4906 (0705) 1024782 500000 49

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 697282 500000 49

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2273339 500000 50

66 Toluene 91 5162 5162 (0742) 2719268 500000 52

64 trans-13-Dichloropropene 75 5649 5649 (0812) 938808 500000 50

69 112-Trichloroethane 83 5820 5820 (0837) 432262 500000 49

71 Tetrachloroethene 166 5576 5576 (0802) 639002 500000 52

73 2-Hexanone 43 6680 6680 (0961) 526223 500000 50

74 Dibromochloromethane 129 6015 6015 (0865) 599464 500000 49

77 12-Dibromoethane 107 6259 6259 (0900) 524614 500000 50

78 Chlorobenzene-d5 117 6954 6954 (1000) 1964266 500000

79 Chlorobenzene 112 6972 6972 (1003) 1781568 500000 51

81 Ethylbenzene 106 7064 7064 (1016) 955894 500000 51

82 m+p-Xylene 106 7277 7277 (1046) 2423002 100000 100

84 o-Xylene 106 7862 7862 (1131) 1181273 500000 51

85 Styrene 104 7942 7942 (1142) 2064560 500000 52

86 Bromoform 173 7911 7911 (1138) 430943 500000 51

88 Isopropylbenzene 105 8350 8350 (1201) 3014281 500000 54

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 870646 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 702309 500000 50

105 13-Dichlorobenzene 146 10331 10331 (0987) 1421450 500000 51

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1082388 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 1464915 500000 51

111 12-Dichlorobenzene 146 11154 11154 (1066) 1324016 500000 50

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 120062 500000 49

114 124-Trichlorobenzene 180 12971 12971 (1239) 678119 500000 51

M 120 12-Dichloroethene (Total) 100 1089149 100000 100

M 121 Xylene (Total) 100 3604275 150000 160

10162012Page 88 of 323

Data File e07840d

Date 17-SEP-2012 0623

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL4 Operator GCMS VOAMS5

10162012Page 89 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07841d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07841dLab Smp Id IC-VMCAL5 Inj Date 17-SEP-2012 0646 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL5Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 7 Calibration Sample Level 5Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 1798263 200000 200

3 Chloromethane 50 1010 1010 (0281) 3551906 200000 190

4 Vinyl Chloride 62 1016 1016 (0283) 2954383 200000 200

6 Bromomethane 94 1175 1175 (0327) 1285567 200000 190

5 Chloroethane 64 1230 1230 (0342) 1005976 200000 180

7 Trichlorofluoromethane 101 1291 1291 (0359) 2495326 200000 200

14 Freon TF 101 1565 1565 (0435) 1913025 200000 220

15 11-Dichloroethene 96 1541 1541 (0429) 1549102 200000 200

16 Acetone 58 1894 1894 (0527) 164598 200000 180

18 Carbon Disulfide 76 1559 1559 (0434) 7384049 200000 210

27 Methyl Acetate 74 1961 1961 (0546) 407713 200000 190

22 Methylene Chloride 49 1851 1851 (0515) 3225631 200000 180

28 MTBE 73 2016 2016 (0561) 7002522 200000 200

25 trans-12-Dichloroethene 96 1943 1943 (0540) 2044335 200000 200

30 11-Dichloroethane 63 2303 2303 (0640) 4556341 200000 200

36 cis-12-Dichloroethene 96 2650 2650 (0737) 2267968 200000 190

10162012Page 90 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07841d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0854) 377317 200000 220

42 Chloroform 83 2839 2839 (0790) 4002506 200000 200

44 Cyclohexane 56 2784 2784 (0774) 4704103 200000 220

43 111-Trichloroethane 97 2979 2979 (0829) 3633125 200000 210

45 Carbon Tetrachloride 117 2930 2930 (0815) 2970592 200000 220

48 Benzene 78 3260 3260 (0468) 9863557 200000 210

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 676105 500000 50

49 12-Dichloroethane 62 3418 3418 (0951) 3236838 200000 190

52 Fluorobenzene 96 3595 3595 (1000) 2534623 500000

54 Trichloroethene 95 3741 3741 (1041) 2397838 200000 200

56 Methyl cyclohexane 83 3729 3729 (1037) 3740947 200000 220

57 12-Dichloropropane 63 4199 4199 (1168) 2762116 200000 200

68 Bromodichloromethane 83 4272 4272 (1188) 3283607 200000 200

67 cis-13-Dichloropropene 75 4912 4912 (0706) 4330221 200000 200

70 4-Methyl-2-Pentanone 43 5631 5631 (0809) 2892746 200000 200

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2337515 500000 50

66 Toluene 91 5162 5162 (0742) 10779721 200000 200

64 trans-13-Dichloropropene 75 5656 5656 (0813) 3942425 200000 200

69 112-Trichloroethane 83 5826 5826 (0837) 1754301 200000 190

71 Tetrachloroethene 166 5582 5582 (0802) 2589541 200000 210

73 2-Hexanone 43 6686 6686 (0961) 2211715 200000 210

74 Dibromochloromethane 129 6021 6021 (0865) 2498269 200000 200

77 12-Dibromoethane 107 6265 6265 (0900) 2110766 200000 200

78 Chlorobenzene-d5 117 6960 6960 (1000) 2007362 500000

79 Chlorobenzene 112 6978 6978 (1003) 7007520 200000 200

81 Ethylbenzene 106 7076 7076 (1017) 3881643 200000 200

82 m+p-Xylene 106 7289 7289 (1047) 9786882 400000 410

84 o-Xylene 106 7869 7869 (1131) 4809215 200000 200

85 Styrene 104 7954 7954 (1143) 8412645 200000 210

86 Bromoform 173 7923 7923 (1138) 1812795 200000 210

88 Isopropylbenzene 105 8356 8356 (1201) 12317103 200000 220(A)

$ 89 Bromofluorobenzene (SUR) 174 8716 8716 (0832) 929176 500000 51

92 1122-Tetrachloroethane 83 9124 9124 (0871) 2898768 200000 200

105 13-Dichlorobenzene 146 10344 10344 (0987) 5787314 200000 200

108 14-Dichlorobenzene-d4 152 10478 10478 (1000) 1134091 500000

109 14-Dichlorobenzene 146 10502 10502 (1002) 5901891 200000 200

111 12-Dichlorobenzene 146 11167 11167 (1066) 5328621 200000 190

112 12-Dibromo-3-chloropropane 75 12240 12240 (1168) 472744 200000 180

114 124-Trichlorobenzene 180 12971 12971 (1238) 2596959 200000 190

M 120 12-Dichloroethene (Total) 100 4312303 400000 380

M 121 Xylene (Total) 100 14596097 600000 620

QC Flag Legend

A - Target compound detected but quantitated amountexceeded maximum amount

10162012Page 91 of 323

Data File e07841d

Date 17-SEP-2012 0646

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL5 Operator GCMS VOAMS5

10162012Page 92 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07842d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07842dLab Smp Id IC-VMCAL6 Inj Date 17-SEP-2012 0710 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL6Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 8 Calibration Sample Level 6Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 4551928 500000 450

3 Chloromethane 50 1010 1010 (0280) 8902969 500000 410

4 Vinyl Chloride 62 1016 1016 (0282) 7332518 500000 420

6 Bromomethane 94 1175 1175 (0326) 3429373 500000 450

5 Chloroethane 64 1230 1230 (0341) 2426216 500000 380

7 Trichlorofluoromethane 101 1297 1297 (0360) 6618134 500000 470

14 Freon TF 101 1571 1571 (0436) 5130629 500000 520(A)

15 11-Dichloroethene 96 1547 1547 (0429) 4214942 500000 490

16 Acetone 58 1894 1894 (0526) 441742 500000 420

18 Carbon Disulfide 76 1559 1559 (0433) 18433408 500000 460

27 Methyl Acetate 74 1961 1961 (0545) 1074355 500000 440

22 Methylene Chloride 49 1851 1851 (0514) 8533685 500000 410

28 MTBE 73 2022 2022 (0562) 17351574 500000 440

25 trans-12-Dichloroethene 96 1943 1943 (0540) 5633771 500000 470

30 11-Dichloroethane 63 2302 2302 (0639) 12326764 500000 460

36 cis-12-Dichloroethene 96 2650 2650 (0736) 6324299 500000 460

10162012Page 93 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07842d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3083 3083 (0856) 1055008 500000 530(A)

42 Chloroform 83 2845 2845 (0790) 11152231 500000 480

44 Cyclohexane 56 2790 2790 (0775) 12852489 500000 540(A)

43 111-Trichloroethane 97 2985 2985 (0829) 10199723 500000 520(A)

45 Carbon Tetrachloride 117 2936 2936 (0815) 8405131 500000 540(A)

48 Benzene 78 3260 3260 (0468) 21876514 500000 410

$ 47 12-Dichloroethane-d4 (SUR) 65 3369 3369 (0936) 782507 500000 51

49 12-Dichloroethane 62 3424 3424 (0951) 9046377 500000 480

52 Fluorobenzene 96 3601 3601 (1000) 2895790 500000

54 Trichloroethene 95 3753 3753 (1042) 7026524 500000 510(A)

56 Methyl cyclohexane 83 3741 3741 (1039) 10227785 500000 530(A)

57 12-Dichloropropane 63 4205 4205 (1168) 7913672 500000 500

68 Bromodichloromethane 83 4284 4284 (1190) 9374106 500000 510(A)

67 cis-13-Dichloropropene 75 4924 4924 (0706) 12299317 500000 520(A)

70 4-Methyl-2-Pentanone 43 5649 5649 (0810) 8212153 500000 510(A)

$ 65 Toluene-d8 (SUR) 98 5113 5113 (0733) 2600040 500000 50

66 Toluene 91 5168 5168 (0741) 23868197 500000 400

64 trans-13-Dichloropropene 75 5668 5668 (0813) 11373599 500000 530(A)

69 112-Trichloroethane 83 5838 5838 (0837) 5071317 500000 500(A)

71 Tetrachloroethene 166 5594 5594 (0802) 7239654 500000 520(A)

73 2-Hexanone 43 6698 6698 (0961) 5590902 500000 470

74 Dibromochloromethane 129 6033 6033 (0865) 7227226 500000 530(A)

77 12-Dibromoethane 107 6277 6277 (0900) 5952425 500000 500(A)

78 Chlorobenzene-d5 117 6972 6972 (1000) 2224153 500000

79 Chlorobenzene 112 6997 6997 (1003) 18374405 500000 460

81 Ethylbenzene 106 7094 7094 (1017) 10693410 500000 500(A)

82 m+p-Xylene 106 7308 7308 (1048) 23238078 100000 880

84 o-Xylene 106 7887 7887 (1131) 12821590 500000 490

85 Styrene 104 7966 7966 (1143) 19831782 500000 440

86 Bromoform 173 7942 7942 (1139) 4974461 500000 520(A)

88 Isopropylbenzene 105 8368 8368 (1200) 26165908 500000 420(A)

$ 89 Bromofluorobenzene (SUR) 174 8728 8728 (0832) 954872 500000 51

92 1122-Tetrachloroethane 83 9143 9143 (0871) 7365342 500000 490

105 13-Dichlorobenzene 146 10362 10362 (0987) 14243841 500000 480

108 14-Dichlorobenzene-d4 152 10496 10496 (1000) 1163568 500000

109 14-Dichlorobenzene 146 10526 10526 (1003) 14602396 500000 470

111 12-Dichlorobenzene 146 11185 11185 (1066) 13405399 500000 480

112 12-Dibromo-3-chloropropane 75 12246 12246 (1167) 1274610 500000 480

114 124-Trichlorobenzene 180 12977 12977 (1236) 6669727 500000 470

M 120 12-Dichloroethene (Total) 100 11958070 100000 940

M 121 Xylene (Total) 100 36059668 150000 1400

QC Flag Legend

A - Target compound detected but quantitated amountexceeded maximum amount

10162012Page 94 of 323

Data File e07842d

Date 17-SEP-2012 0710

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL6 Operator GCMS VOAMS5

10162012Page 95 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10112012 2050

09172012 0449

09172012 0710

CCVIS 460-1316562

Rtx-VMS

TestAmerica Edison

Lab File ID e08976d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Dichlorodifluoromethane 0194701761 01000 221 200 105 250Ave

Chloromethane 0322303733 01000 173 200 -137 250Ave

Vinyl chloride 0274402985 01000 184 200 -81 250Ave

Bromomethane 0159401312 01000 243 200 215 250Ave

Chloroethane 0127501099 01000 232 200 160 250Ave

Trichlorofluoromethane 0296002422 01000 244 200 222 250Ave

11-Dichloroethene 0161001496 01000 215 200 76 250Ave

Carbon disulfide 0655806887 01000 190 200 -48 250Ave

112-Trichloro-122-trifluoroethane

0198901691 01000 235 200 176 250Ave

Methylene Chloride 0341503576 01000 191 200 -45 250Ave

Acetone 0021400184 01000 233 200 164 250Ave

trans-12-Dichloroethene 0208902052 01000 204 200 18 250Ave

Methyl acetate 0037700426 01000 177 200 -115 250Ave

Methyl tert-butyl ether 0665806838 01000 195 200 -26 250Ave

11-Dichloroethane 0443404582 01000 194 200 -32 250Ave

cis-12-Dichloroethene 0227602361 01000 193 200 -36 250Ave

Cyclohexane 0338904145 01000 163 200 -183 250Ave

Chloroform 0397703982 01000 200 200 -01 250Ave

Carbon tetrachloride 0281602705 01000 208 200 41 250Ave

111-Trichloroethane 0352303375 01000 209 200 44 250Ave

2-Butanone (MEK) 0035400341 01000 208 200 40 250Ave

Benzene 10301190 01000 173 200 -134 250Ave

12-Dichloroethane 0331603284 01000 202 200 10 250Ave

Methylcyclohexane 0280603325 01000 169 200 -156 250Ave

Trichloroethene 0228602385 01000 192 200 -41 250Ave

12-Dichloropropane 0242002756 01000 176 200 -122 250Ave

Dichlorobromomethane 0303603195 01000 190 200 -50 250Ave

cis-13-Dichloropropene 0438605308 01000 165 200 -174 250Ave

Toluene 12151323 01000 184 200 -81 250Ave

Tetrachloroethene 0302803113 01000 195 200 -27 250Ave

4-Methyl-2-pentanone (MIBK) 0273203593 01000 152 200 -240 250Ave

trans-13-Dichloropropene 0396604819 01000 165 200 -177 250Ave

112-Trichloroethane 0185102264 01000 164 200 -182 250Ave

Chlorodibromomethane 0265003083 01000 172 200 -141 250Ave

12-Dibromoethane 0231002670 01000 173 200 -135 250Ave

2-Hexanone 0209702668 01000 157 200 -214 250Ave

Chlorobenzene 0830208882 01000 187 200 -65 250Ave

Ethylbenzene 0437104756 01000 184 200 -81 250Ave

m-Xylene amp p-Xylene 0555805917 01000 376 400 -61 250Ave

o-Xylene 0545405886 01000 185 200 -73 250Ave

FORM VII 8260B

10162012Page 96 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10112012 2050

09172012 0449

09172012 0710

CCVIS 460-1316562

Rtx-VMS

TestAmerica Edison

Lab File ID e08976d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Bromoform 0188102147 01000 175 200 -124 250Ave

Styrene 092181000 01000 184 200 -78 250Ave

Isopropylbenzene 13421415 01000 190 200 -52 250Ave

1122-Tetrachloroethane 0512306462 01000 159 200 -207 250Ave

13-Dichlorobenzene 11861279 01000 186 200 -72 250Ave

14-Dichlorobenzene 12311326 01000 186 200 -72 250Ave

12-Dichlorobenzene 11211209 01000 185 200 -73 250Ave

12-Dibromo-3-Chloropropane 0086101130 01000 152 200 -238 250Ave

124-Trichlorobenzene 0630306118 01000 206 200 30 250Ave

12-Dichloroethane-d4 (Surr) 0310902638 01000 589 500 178 250Ave

Toluene-d8 (Surr) 11551167 01000 495 500 -11 250Ave

4-Bromofluorobenzene 0811108079 01000 502 500 04 250Ave

FORM VII 8260B

10162012Page 97 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08976d Report Date 11-Oct-2012 2130

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08976dLab Smp Id CCVIS Inj Date 11-OCT-2012 2050 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info CCVISMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 1 Continuing Calibration SampleDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0900 0900 (0250) 102235 200000 22

3 Chloromethane 50 1016 1016 (0282) 169224 200000 17

4 Vinyl Chloride 62 1028 1028 (0286) 144069 200000 18

6 Bromomethane 94 1181 1181 (0328) 83687 200000 24

5 Chloroethane 64 1242 1242 (0345) 66969 200000 23

7 Trichlorofluoromethane 101 1303 1303 (0362) 155393 200000 24

14 Freon TF 101 1577 1577 (0438) 104446 200000 24

15 11-Dichloroethene 96 1553 1553 (0431) 84531 200000 22

16 Acetone 58 1894 1894 (0526) 11228 200000 23

18 Carbon Disulfide 76 1571 1571 (0436) 344348 200000 19

27 Methyl Acetate 74 1967 1967 (0546) 19813 200000 18

22 Methylene Chloride 49 1864 1864 (0518) 179288 200000 19

28 MTBE 73 2022 2022 (0562) 349596 200000 19

25 trans-12-Dichloroethene 96 1949 1949 (0541) 109681 200000 20

30 11-Dichloroethane 63 2309 2309 (0641) 232818 200000 19

36 cis-12-Dichloroethene 96 2656 2656 (0738) 119502 200000 19

10162012Page 98 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08976d Report Date 11-Oct-2012 2130

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0854) 18598 200000 21

42 Chloroform 83 2845 2845 (0790) 208815 200000 20

44 Cyclohexane 56 2784 2784 (0773) 177923 200000 16

43 111-Trichloroethane 97 2985 2985 (0829) 185002 200000 21

45 Carbon Tetrachloride 117 2937 2937 (0815) 147853 200000 21

48 Benzene 78 3260 3260 (0469) 476925 200000 17

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0934) 408134 500000 59

49 12-Dichloroethane 62 3418 3418 (0949) 174132 200000 20

52 Fluorobenzene 96 3601 3601 (1000) 1312656 500000

54 Trichloroethene 95 3741 3741 (1039) 120041 200000 19

56 Methyl cyclohexane 83 3729 3729 (1036) 147336 200000 17

57 12-Dichloropropane 63 4199 4199 (1166) 127078 200000 18

68 Bromodichloromethane 83 4272 4272 (1186) 159386 200000 19

67 cis-13-Dichloropropene 75 4912 4912 (0706) 203059 200000 16

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 126467 200000 15

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1336847 500000 49

66 Toluene 91 5162 5162 (0742) 562689 200000 18

64 trans-13-Dichloropropene 75 5649 5649 (0812) 183587 200000 16

69 112-Trichloroethane 83 5820 5820 (0837) 85707 200000 16

71 Tetrachloroethene 166 5582 5582 (0803) 140177 200000 19

73 2-Hexanone 43 6680 6680 (0961) 97080 200000 16

74 Dibromochloromethane 129 6021 6021 (0866) 122657 200000 17

77 12-Dibromoethane 107 6265 6265 (0901) 106920 200000 17

78 Chlorobenzene-d5 117 6954 6954 (1000) 1157341 500000

79 Chlorobenzene 112 6972 6972 (1003) 384334 200000 19

81 Ethylbenzene 106 7064 7064 (1016) 202362 200000 18

82 m+p-Xylene 106 7277 7277 (1046) 514606 400000 38

84 o-Xylene 106 7862 7862 (1131) 252476 200000 18

85 Styrene 104 7942 7942 (1142) 426740 200000 18

86 Bromoform 173 7911 7911 (1138) 87078 200000 18

88 Isopropylbenzene 105 8350 8350 (1201) 621124 200000 19

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 541700 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 136860 200000 16

105 13-Dichlorobenzene 146 10331 10331 (0987) 316835 200000 18

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 667834 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 328709 200000 18

111 12-Dichlorobenzene 146 11148 11148 (1065) 299393 200000 18

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 23001 200000 15

114 124-Trichlorobenzene 180 12977 12977 (1240) 168371 200000 21

M 120 12-Dichloroethene (Total) 100 229183 400000 40

M 121 Xylene (Total) 100 767082 600000 56

10162012Page 99 of 323

Data File e08976d

Date 11-OCT-2012 2050

Client ID Instrument VOAMS5i

Sample Info CCVIS Operator GCMS VOAMS5

10162012Page 100 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10122012 0114

09172012 0449

09172012 0710

CCV 460-13165610

Rtx-VMS

TestAmerica Edison

Lab File ID e08987d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Dichlorodifluoromethane 0166601761 01000 189 200 -54 250Ave

Chloromethane 0311403733 01000 167 200 -166 250Ave

Vinyl chloride 0256002985 01000 172 200 -142 250Ave

Bromomethane 0162301312 01000 247 200 237 250Ave

Chloroethane 0127201099 01000 231 200 157 250Ave

Trichlorofluoromethane 0257102422 01000 212 200 62 250Ave

11-Dichloroethene 0184901496 01000 247 200 236 250Ave

112-Trichloro-122-trifluoroethane

0225501691 01000 267 200 334 250Ave

Carbon disulfide 0788506887 01000 229 200 145 250Ave

Methylene Chloride 0351303576 01000 196 200 -18 250Ave

Acetone 0022000184 01000 239 200 197 250Ave

trans-12-Dichloroethene 0232002052 01000 226 200 130 250Ave

Methyl acetate 0048700426 01000 228 200 141 250Ave

Methyl tert-butyl ether 0769506838 01000 225 200 125 250Ave

11-Dichloroethane 0469804582 01000 205 200 25 250Ave

cis-12-Dichloroethene 0240902361 01000 204 200 20 250Ave

Cyclohexane 0384004145 01000 185 200 -74 250Ave

Chloroform 0438203982 01000 220 200 100 250Ave

Carbon tetrachloride 0291802705 01000 216 200 79 250Ave

111-Trichloroethane 0362803375 01000 215 200 75 250Ave

2-Butanone (MEK) 0042500341 01000 250 200 248 250Ave

Benzene 11151190 01000 188 200 -62 250Ave

12-Dichloroethane 0359603284 01000 219 200 95 250Ave

Methylcyclohexane 0344803325 01000 207 200 37 250Ave

Trichloroethene 0248302385 01000 208 200 41 250Ave

12-Dichloropropane 0265202756 01000 192 200 -38 250Ave

Dichlorobromomethane 0339803195 01000 213 200 63 250Ave

cis-13-Dichloropropene 0490405308 01000 185 200 -76 250Ave

Toluene 12801323 01000 194 200 -32 250Ave

Tetrachloroethene 0323103113 01000 208 200 38 250Ave

4-Methyl-2-pentanone (MIBK) 0319703593 01000 178 200 -110 250Ave

trans-13-Dichloropropene 0454104819 01000 188 200 -58 250Ave

112-Trichloroethane 0212502264 01000 188 200 -61 250Ave

Chlorodibromomethane 0306403083 01000 199 200 -06 250Ave

12-Dibromoethane 0261302670 01000 196 200 -22 250Ave

2-Hexanone 0243802668 01000 183 200 -86 250Ave

Chlorobenzene 0879308882 01000 198 200 -10 250Ave

Ethylbenzene 0463104756 01000 195 200 -26 250Ave

m-Xylene amp p-Xylene 0587505917 01000 397 400 -07 250Ave

o-Xylene 0578505886 01000 197 200 -17 250Ave

FORM VII 8260B

10162012Page 101 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10122012 0114

09172012 0449

09172012 0710

CCV 460-13165610

Rtx-VMS

TestAmerica Edison

Lab File ID e08987d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Bromoform 0223102147 01000 208 200 39 250Ave

Styrene 099051000 01000 198 200 -09 250Ave

Isopropylbenzene 14391415 01000 203 200 17 250Ave

1122-Tetrachloroethane 0579606462 01000 179 200 -103 250Ave

13-Dichlorobenzene 12591279 01000 197 200 -15 250Ave

14-Dichlorobenzene 13061326 01000 197 200 -15 250Ave

12-Dichlorobenzene 12151209 01000 201 200 05 250Ave

12-Dibromo-3-Chloropropane 0102901130 01000 182 200 -90 250Ave

124-Trichlorobenzene 0743906118 01000 243 200 216 250Ave

12-Dichloroethane-d4 (Surr) 0320902638 01000 608 500 216 250Ave

Toluene-d8 (Surr) 11471167 01000 491 500 -18 250Ave

4-Bromofluorobenzene 0806308079 01000 499 500 -02 250Ave

FORM VII 8260B

10162012Page 102 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12abe08987d Report Date 12-Oct-2012 0132

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12abe08987dLab Smp Id CCV Inj Date 12-OCT-2012 0114 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info CCVMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12ab8260DE_09mMeth Date 12-Oct-2012 0132 ken Quant Type ISTDCal Date 12-OCT-2012 0114 Cal File e08987dAls bottle 12 Continuing Calibration SampleDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0894 (0249) 84911 200000 19

3 Chloromethane 50 1016 1016 (0283) 158694 200000 17

4 Vinyl Chloride 62 1022 1022 (0284) 130464 200000 17

6 Bromomethane 94 1181 1181 (0328) 82695 200000 25

5 Chloroethane 64 1236 1236 (0344) 64840 200000 23

7 Trichlorofluoromethane 101 1297 1297 (0361) 131020 200000 21

14 Freon TF 101 1565 1565 (0435) 114931 200000 27

15 11-Dichloroethene 96 1547 1547 (0430) 94244 200000 25

16 Acetone 58 1894 1894 (0527) 11208 200000 24

18 Carbon Disulfide 76 1565 1565 (0435) 401807 200000 23

27 Methyl Acetate 74 1961 1961 (0546) 24794 200000 23

22 Methylene Chloride 49 1857 1857 (0517) 179010 200000 20

28 MTBE 73 2022 2022 (0562) 392131 200000 22

25 trans-12-Dichloroethene 96 1943 1943 (0540) 118223 200000 23

30 11-Dichloroethane 63 2302 2302 (0640) 239419 200000 20

36 cis-12-Dichloroethene 96 2650 2650 (0737) 122782 200000 20

10162012Page 103 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12abe08987d Report Date 12-Oct-2012 0132

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0856) 21666 200000 25

42 Chloroform 83 2845 2845 (0791) 223324 200000 22

44 Cyclohexane 56 2784 2784 (0774) 195679 200000 18

43 111-Trichloroethane 97 2979 2979 (0829) 184861 200000 21

45 Carbon Tetrachloride 117 2930 2930 (0815) 148689 200000 22

48 Benzene 78 3260 3260 (0469) 501947 200000 19

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 408924 500000 61

49 12-Dichloroethane 62 3418 3418 (0951) 183231 200000 22

52 Fluorobenzene 96 3595 3595 (1000) 1274024 500000

54 Trichloroethene 95 3741 3741 (1041) 126518 200000 21

56 Methyl cyclohexane 83 3723 3723 (1036) 175700 200000 21

57 12-Dichloropropane 63 4192 4192 (1166) 135130 200000 19

68 Bromodichloromethane 83 4272 4272 (1188) 173147 200000 21

67 cis-13-Dichloropropene 75 4906 4906 (0705) 220680 200000 18

70 4-Methyl-2-Pentanone 43 5631 5631 (0810) 143892 200000 18

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1290179 500000 49

66 Toluene 91 5162 5162 (0742) 576151 200000 19

64 trans-13-Dichloropropene 75 5649 5649 (0812) 204342 200000 19

69 112-Trichloroethane 83 5820 5820 (0837) 95620 200000 19

71 Tetrachloroethene 166 5582 5582 (0803) 145404 200000 21

73 2-Hexanone 43 6680 6680 (0961) 109697 200000 18

74 Dibromochloromethane 129 6015 6015 (0865) 137888 200000 20

77 12-Dibromoethane 107 6265 6265 (0901) 117575 200000 20

78 Chlorobenzene-d5 117 6954 6954 (1000) 1125053 500000

79 Chlorobenzene 112 6972 6972 (1003) 395719 200000 20

81 Ethylbenzene 106 7064 7064 (1016) 208414 200000 19

82 m+p-Xylene 106 7277 7277 (1046) 528781 400000 40

84 o-Xylene 106 7856 7856 (1130) 260320 200000 20

85 Styrene 104 7942 7942 (1142) 445737 200000 20

86 Bromoform 173 7917 7917 (1139) 100375 200000 21

88 Isopropylbenzene 105 8344 8344 (1200) 647568 200000 20

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 536325 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 154190 200000 18

105 13-Dichlorobenzene 146 10331 10331 (0987) 335032 200000 20

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 665092 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 347387 200000 20

111 12-Dichlorobenzene 146 11148 11148 (1065) 323155 200000 20

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 27376 200000 18

114 124-Trichlorobenzene 180 12977 12977 (1240) 197894 200000 24

M 120 12-Dichloroethene (Total) 100 241005 400000 43

M 121 Xylene (Total) 100 789101 600000 59

10162012Page 104 of 323

Data File e08987d

Date 12-OCT-2012 0114

Client ID Instrument VOAMS5i

Sample Info CCV Operator GCMS VOAMS5

10162012Page 105 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07834d Report Date 17-Sep-2012 0605

TestAmerica

Data file chemVOAMS5i8260DE09-17-1217sep12be07834dLab Smp Id BFB Inj Date 17-SEP-2012 0324 Operator VOAMS 1 Inst ID VOAMS5iSmp Info BFBMisc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12bBFBDELmMeth Date 27-Feb-2012 1508 sylvanus Quant Type ISTDCal Date Cal File Als bottle 2 QC Sample BFBDil Factor 100000 Integrator HP RTE Compound Sublist allsubTarget Version 350 Sample Matrix WATERProcessing Host hpd2

Concentration Formula Amt DF Uf Vf VI CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorUf 100000 ng unit correction factorVf 100000 Volumetric correction factorVI 100000 Injection Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT (REL RT) MASS RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ==== ======== ======= ======= ============ =====

1 BFB CAS 460-00-4

2352 2600 (0000) 95 195072 000- 10000 10000

2352 2600 (0000) 50 42624 1500- 4000 2185

2352 2600 (0000) 75 102376 3000- 6000 5248

2352 2600 (0000) 96 12530 500- 900 642

2352 2600 (0000) 173 0 000- 200 000

2352 2600 (0000) 174 155200 5000- 10000 7956

2352 2600 (0000) 175 12902 500- 900 831

2352 2600 (0000) 176 148480 9500- 10100 9567

2352 2600 (0000) 177 9343 500- 900 629

-------------------------------------------------------------------------------

10162012Page 106 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

10162012Page 107 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

1 BFB

RELATIVE me ION ABUNDANCE CRITERIA ABUNDANCE

+-----+------------------------------------------+---------------------+| | | || 95 | Base Peak 100 relative abundance | 10000 || 50 | 1500 - 4000 of mass 95 | 2185 || 75 | 3000 - 6000 of mass 95 | 5248 || 96 | 500 - 900 of mass 95 | 642 || 173 | Less than 200 of mass 174 | 000 ( 000) || 174 | 5000 - 10000 of mass 95 | 7956 || 175 | 500 - 900 of mass 174 | 661 ( 831) || 176 | 9500 - 10100 of mass 174 | 7612 ( 9567) || 177 | 500 - 900 of mass 176 | 479 ( 629) |+-----+------------------------------------------+---------------------+

10162012Page 108 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

Data File chemVOAMS5i8260DE09-17-1217sep12be07834dSpectrum Avg Scans 50-52 ( 235) Background Scan 46

Location of Maximum 9500Number of points 151

mz Y mz Y mz Y mz Y+------------------+------------------+------------------+------------------+| 3500 53 | 7700 1350 | 12300 88 | 17700 9343 || 3600 1914 | 7800 695 | 12400 252 | 17800 381 || 3700 12535 | 7900 5782 | 12500 148 | 18000 35 || 3800 10760 | 8000 1455 | 12700 282 | 18300 181 || 3900 3962 | 8100 5745 | 12800 338 | 18600 248 |+------------------+------------------+------------------+------------------+| 4100 387 | 8200 905 | 12900 75 | 18700 80 || 4400 707 | 8300 42 | 13000 926 | 18800 162 || 4500 1464 | 8500 229 | 13100 166 | 18900 142 || 4600 281 | 8600 239 | 13200 7 | 19100 151 || 4700 3334 | 8700 7427 | 13400 27 | 19200 54 |+------------------+------------------+------------------+------------------+| 4800 1491 | 8800 7774 | 13700 332 | 19300 44 || 4900 8401 | 9100 1022 | 13800 172 | 19400 110 || 5000 42624 | 9200 5845 | 14000 185 | 19600 46 || 5100 13346 | 9300 8046 | 14100 1957 | 19800 171 || 5200 539 | 9400 21672 | 14200 53 | 20000 162 |+------------------+------------------+------------------+------------------+| 5300 13 | 9500 195072 | 14300 1698 | 20200 62 || 5400 14 | 9600 12530 | 14400 295 | 20300 48 || 5500 230 | 9700 551 | 14500 186 | 20400 104 || 5600 3600 | 9900 79 | 14600 115 | 20500 34 || 5700 5500 | 10000 36 | 14700 156 | 20700 223 |+------------------+------------------+------------------+------------------+| 5800 113 | 10100 136 | 14800 465 | 20900 81 || 5900 106 | 10200 36 | 14900 118 | 21500 80 || 6000 1861 | 10300 237 | 15000 105 | 21900 89 || 6100 10125 | 10400 905 | 15300 459 | 22000 60 || 6200 9219 | 10500 514 | 15400 192 | 22600 84 |+------------------+------------------+------------------+------------------+| 6300 7541 | 10600 1054 | 15700 390 | 23000 188 || 6400 270 | 10700 304 | 16000 378 | 23100 74 || 6500 625 | 11000 398 | 16100 530 | 23500 107 || 6600 51 | 11100 151 | 16400 54 | 23900 43 || 6700 378 | 11200 121 | 16700 172 | 24600 123 |+------------------+------------------+------------------+------------------+| 6800 20496 | 11300 247 | 16800 205 | 24700 37 || 6900 19976 | 11500 421 | 16900 243 | 25000 57 || 7000 1570 | 11600 358 | 17000 351 | 25200 33 || 7200 740 | 11700 1343 | 17100 439 | 25500 46 || 7300 9006 | 11800 855 | 17200 227 | 26200 43 |+------------------+------------------+------------------+------------------+| 7400 34320 | 11900 733 | 17400 155200 | 26400 63 || 7500 102376 | 12100 68 | 17500 12902 | 26500 45 || 7600 8204 | 12200 77 | 17600 148480 | |+------------------+------------------+------------------+------------------+

10162012Page 109 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08975d Report Date 11-Oct-2012 2012

TestAmerica

Data file chemVOAMS5i8260DE09-17-1211oct12be08975dLab Smp Id BFB Inj Date 11-OCT-2012 2008 Operator VOAMS 1 Inst ID VOAMS5iSmp Info BFBMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12bBFBDELmMeth Date 27-Feb-2012 1508 sylvanus Quant Type ISTDCal Date Cal File Als bottle 2 QC Sample BFBDil Factor 100000 Integrator HP RTE Compound Sublist allsubTarget Version 350 Sample Matrix WATERProcessing Host hpd2

Concentration Formula Amt DF Uf Vf VI CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorUf 100000 ng unit correction factorVf 100000 Volumetric correction factorVI 100000 Injection Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT (REL RT) MASS RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ==== ======== ======= ======= ============ =====

1 BFB CAS 460-00-4

2352 2600 (0000) 95 135522 000- 10000 10000

2352 2600 (0000) 50 29541 1500- 4000 2180

2352 2600 (0000) 75 70179 3000- 6000 5178

2352 2600 (0000) 96 8846 500- 900 653

2352 2600 (0000) 173 896 000- 200 074

2352 2600 (0000) 174 121433 5000- 10000 8960

2352 2600 (0000) 175 9704 500- 900 799

2352 2600 (0000) 176 118148 9500- 10100 9729

2352 2600 (0000) 177 7241 500- 900 613

-------------------------------------------------------------------------------

10162012Page 110 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

10162012Page 111 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

1 BFB

RELATIVE me ION ABUNDANCE CRITERIA ABUNDANCE

+-----+------------------------------------------+---------------------+| | | || 95 | Base Peak 100 relative abundance | 10000 || 50 | 1500 - 4000 of mass 95 | 2180 || 75 | 3000 - 6000 of mass 95 | 5178 || 96 | 500 - 900 of mass 95 | 653 || 173 | Less than 200 of mass 174 | 066 ( 074) || 174 | 5000 - 10000 of mass 95 | 8960 || 175 | 500 - 900 of mass 174 | 716 ( 799) || 176 | 9500 - 10100 of mass 174 | 8718 ( 9729) || 177 | 500 - 900 of mass 176 | 534 ( 613) |+-----+------------------------------------------+---------------------+

10162012Page 112 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

Data File chemVOAMS5i8260DE09-17-1211oct12be08975dSpectrum Avg Scans 50-52 ( 235) Background Scan 46

Location of Maximum 9500Number of points 149

mz Y mz Y mz Y mz Y+------------------+------------------+------------------+------------------+| 3600 1294 | 7800 45 | 13100 382 | 18200 69 || 3700 8431 | 7900 4274 | 13200 84 | 18300 115 || 3800 6991 | 8000 1313 | 13400 26 | 18600 116 || 3900 2548 | 8100 3602 | 13500 465 | 18700 340 || 4000 550 | 8200 868 | 13600 63 | 18800 34 |+------------------+------------------+------------------+------------------+| 4100 253 | 8300 128 | 13700 225 | 18900 18 || 4200 100 | 8400 171 | 13900 69 | 19900 265 || 4400 553 | 8500 53 | 14000 115 | 20100 29 || 4500 1283 | 8700 5211 | 14100 1442 | 20400 84 || 4700 1587 | 8800 4550 | 14200 269 | 20500 33 |+------------------+------------------+------------------+------------------+| 4800 651 | 9100 642 | 14300 1465 | 20600 138 || 4900 5880 | 9200 3657 | 14400 23 | 20700 20 || 5000 29536 | 9300 6715 | 14500 103 | 20900 79 || 5100 8612 | 9400 15687 | 14700 151 | 21000 74 || 5200 396 | 9500 135488 | 14800 365 | 21100 1 |+------------------+------------------+------------------+------------------+| 5300 107 | 9600 8846 | 14900 429 | 21200 140 || 5500 726 | 9700 271 | 15100 54 | 21300 52 || 5600 1691 | 9800 1 | 15300 430 | 21400 189 || 5700 4463 | 10000 110 | 15400 385 | 22100 72 || 5800 245 | 10300 207 | 15500 1021 | 22200 35 |+------------------+------------------+------------------+------------------+| 5900 116 | 10400 668 | 15600 236 | 22400 188 || 6000 1281 | 10600 562 | 15700 473 | 22600 79 || 6100 6975 | 10700 159 | 15800 3 | 22800 39 || 6200 7260 | 11000 145 | 15900 410 | 23000 95 || 6300 5465 | 11100 68 | 16100 441 | 23300 189 |+------------------+------------------+------------------+------------------+| 6400 672 | 11200 80 | 16400 208 | 23400 42 || 6500 144 | 11300 261 | 16500 57 | 23500 36 || 6600 201 | 11600 813 | 17000 641 | 23600 58 || 6700 729 | 11700 882 | 17100 38 | 24100 103 || 6800 14333 | 11800 446 | 17200 338 | 24700 36 |+------------------+------------------+------------------+------------------+| 6900 14506 | 11900 1049 | 17300 896 | 25100 40 || 7000 1361 | 12000 38 | 17400 121432 | 25500 61 || 7200 782 | 12100 249 | 17500 9704 | 25600 33 || 7300 6586 | 12400 108 | 17600 118144 | 26000 59 || 7400 24016 | 12600 138 | 17700 7241 | 26500 78 |+------------------+------------------+------------------+------------------+| 7500 70176 | 12700 39 | 17900 19 | || 7600 5444 | 12900 479 | 18000 29 | || 7700 507 | 13000 702 | 18100 322 | |+------------------+------------------+------------------+------------------+

10162012Page 113 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014U1634-04-4 Methyl tert-butyl ether 014

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 114 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

99 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

95 70-130460-00-4 4-Bromofluorobenzene

96 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 115 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 116 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08981d Report Date 12-Oct-2012 0041

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08981dLab Smp Id MB Inj Date 11-OCT-2012 2247 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info MBMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 6 QC Sample BLANKDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 381607 495518 50

52 Fluorobenzene 96 3595 3601 (1000) 1238441 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1209056 482553 48

78 Chlorobenzene-d5 117 6954 6954 (1000) 1084553 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 494380 477044 48

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 638826 500000

10162012Page 117 of 323

Data File e08981d

Date 11-OCT-2012 2247

Client ID Instrument VOAMS5i

Sample Info MB Operator GCMS VOAMS5

10162012Page 118 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1316563

Matrix e08977dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2113

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 006071-55-6 111-Trichloroethane 210

10 02275-71-8 Dichlorodifluoromethane 181

10 01074-87-3 Chloromethane 210

10 01475-01-4 Vinyl chloride 203

10 01874-83-9 Bromomethane 211

10 04096-12-8 12-Dibromo-3-Chloropropane 222

10 02195-50-1 12-Dichlorobenzene 209

10 01575-69-4 Trichlorofluoromethane 190

10 009075-35-4 11-Dichloroethene 223

10 009078-87-5 12-Dichloropropane 211

10 008076-13-1 112-Trichloro-122-trifluoroethane

203

50 2767-64-1 Acetone 250

10 01375-15-0 Carbon disulfide 218

20 03479-20-9 Methyl acetate 220

10 01875-09-2 Methylene Chloride 200

10 013156-60-5 trans-12-Dichloroethene 216

10 020124-48-1 Chlorodibromomethane 217

10 0141634-04-4 Methyl tert-butyl ether 207

10 01775-00-3 Chloroethane 201

10 01375-34-3 11-Dichloroethane 204

10 018156-59-2 cis-12-Dichloroethene 211

50 2378-93-3 2-Butanone (MEK) 214

10 008067-66-3 Chloroform 205

10 010100-41-4 Ethylbenzene 206

10 016110-82-7 Cyclohexane 208

10 006056-23-5 Carbon tetrachloride 211

10 008071-43-2 Benzene 212

10 019107-06-2 12-Dichloroethane 204

10 009079-01-6 Trichloroethene 212

10 014108-87-2 Methylcyclohexane 215

10 01275-27-4 Dichlorobromomethane 214

10 01810061-01-5 cis-13-Dichloropropene 216

50 099108-10-1 4-Methyl-2-pentanone (MIBK) 214

10 015108-88-3 Toluene 205

10 02410061-02-6 trans-13-Dichloropropene 215

FORM I 8260B

10162012Page 119 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1316563

Matrix e08977dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2113

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 01979-00-5 112-Trichloroethane 217

10 010127-18-4 Tetrachloroethene 210

50 050591-78-6 2-Hexanone 201

10 028106-93-4 12-Dibromoethane 215

10 011108-90-7 Chlorobenzene 206

30 0361330-20-7 Xylenes Total 612

10 012100-42-5 Styrene 207

10 01975-25-2 Bromoform 217

10 008098-82-8 Isopropylbenzene 207

10 01679-34-5 1122-Tetrachloroethane 210

10 014541-73-1 13-Dichlorobenzene 204

10 023106-46-7 14-Dichlorobenzene 204

10 034120-82-1 124-Trichlorobenzene 220

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

97 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 120 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08977d Report Date 11-Oct-2012 2301

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08977dLab Smp Id LCS Inj Date 11-OCT-2012 2113 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info LCSMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 2 QC Sample BSDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 92905 180886 18

3 Chloromethane 50 1016 1016 (0283) 178821 210339 21

4 Vinyl Chloride 62 1022 1028 (0284) 146748 202753 20

6 Bromomethane 94 1181 1181 (0328) 88580 210689 21

5 Chloroethane 64 1236 1242 (0344) 67759 201399 20

7 Trichlorofluoromethane 101 1297 1303 (0361) 148657 190423 19

14 Freon TF 101 1565 1577 (0435) 106548 203057 20

15 11-Dichloroethene 96 1547 1553 (0430) 94737 223085 22

16 Acetone 58 1900 1894 (0529) 14083 249674 25

18 Carbon Disulfide 76 1565 1571 (0435) 377236 218062 22

27 Methyl Acetate 74 1961 1967 (0546) 21873 219755 22

22 Methylene Chloride 49 1858 1864 (0517) 180593 200499 20

28 MTBE 73 2022 2022 (0562) 363998 207251 21

25 trans-12-Dichloroethene 96 1943 1949 (0540) 119022 216004 22

30 11-Dichloroethane 63 2303 2309 (0640) 238759 204130 20

36 cis-12-Dichloroethene 96 2650 2656 (0737) 126688 211021 21

10162012Page 121 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08977d Report Date 11-Oct-2012 2301

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 20020 214276 21

42 Chloroform 83 2845 2845 (0791) 215227 205163 20

44 Cyclohexane 56 2778 2784 (0773) 186275 208395 21

43 111-Trichloroethane 97 2979 2985 (0829) 195599 210453 21

45 Carbon Tetrachloride 117 2931 2937 (0815) 156464 210644 21

48 Benzene 78 3260 3260 (0469) 500200 211727 21

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 391700 477589 48

49 12-Dichloroethane 62 3412 3418 (0949) 178793 204379 20

52 Fluorobenzene 96 3595 3601 (1000) 1318918 500000

54 Trichloroethene 95 3735 3741 (1039) 127803 211922 21

56 Methyl cyclohexane 83 3723 3729 (1036) 159134 214991 21

57 12-Dichloropropane 63 4192 4199 (1166) 134808 211159 21

68 Bromodichloromethane 83 4272 4272 (1188) 171399 214054 21

67 cis-13-Dichloropropene 75 4906 4912 (0705) 217526 216258 22

70 4-Methyl-2-Pentanone 43 5631 5625 (0810) 134218 214248 21

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1312817 495616 50

66 Toluene 91 5162 5162 (0742) 572353 205343 20

64 trans-13-Dichloropropene 75 5650 5649 (0812) 195539 215018 22

69 112-Trichloroethane 83 5820 5820 (0837) 92220 217218 22

71 Tetrachloroethene 166 5582 5582 (0803) 145712 209847 21

73 2-Hexanone 43 6680 6680 (0961) 96649 200980 20

74 Dibromochloromethane 129 6015 6021 (0865) 132048 217333 22

77 12-Dibromoethane 107 6259 6265 (0900) 113742 214758 21

78 Chlorobenzene-d5 117 6954 6954 (1000) 1146590 500000

79 Chlorobenzene 112 6972 6972 (1003) 392243 206030 21

81 Ethylbenzene 106 7064 7064 (1016) 206211 205716 20

82 m+p-Xylene 106 7277 7277 (1046) 519872 407882 41

84 o-Xylene 106 7856 7862 (1130) 254939 203845 20

85 Styrene 104 7942 7942 (1142) 437977 207191 21

86 Bromoform 173 7911 7911 (1138) 93696 217219 22

88 Isopropylbenzene 105 8344 8350 (1200) 637526 207206 21

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 538047 484974 48

92 1122-Tetrachloroethane 83 9112 9112 (0871) 147339 210261 21

105 13-Dichlorobenzene 146 10325 10331 (0987) 330263 203584 20

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 683882 500000

109 14-Dichlorobenzene 146 10484 10490 (1002) 343961 204369 20

111 12-Dichlorobenzene 146 11148 11148 (1065) 320073 208797 21

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 26198 222454 22

114 124-Trichlorobenzene 180 12977 12977 (1240) 189475 219787 22

M 120 12-Dichloroethene (Total) 100 245711 427025 43

M 121 Xylene (Total) 100 774811 611727 61

10162012Page 122 of 323

Data File e08977d

Date 11-OCT-2012 2113

Client ID Instrument VOAMS5i

Sample Info LCS Operator GCMS VOAMS5

10162012Page 123 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MS

Matrix e08985dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0027

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 03071-55-6 111-Trichloroethane 103

50 1175-71-8 Dichlorodifluoromethane 865

50 05074-87-3 Chloromethane 102

50 07075-01-4 Vinyl chloride 104

50 09074-83-9 Bromomethane 107

50 2096-12-8 12-Dibromo-3-Chloropropane 121

50 1195-50-1 12-Dichlorobenzene 107

50 07575-69-4 Trichlorofluoromethane 121

50 04575-35-4 11-Dichloroethene 108

50 04578-87-5 12-Dichloropropane 111

50 04076-13-1 112-Trichloro-122-trifluoroethane

102

25 1367-64-1 Acetone 986

50 06575-15-0 Carbon disulfide 113

10 1779-20-9 Methyl acetate 100

50 09075-09-2 Methylene Chloride 106

50 065156-60-5 trans-12-Dichloroethene 106

50 10124-48-1 Chlorodibromomethane 116

50 0701634-04-4 Methyl tert-butyl ether 114

50 08575-00-3 Chloroethane 116

50 06575-34-3 11-Dichloroethane 104

50 090156-59-2 cis-12-Dichloroethene 105

25 1278-93-3 2-Butanone (MEK) 111

50 04067-66-3 Chloroform 108

50 050100-41-4 Ethylbenzene 107

50 080110-82-7 Cyclohexane 108

50 03056-23-5 Carbon tetrachloride 105

50 04071-43-2 Benzene 106

50 095107-06-2 12-Dichloroethane 107

50 04579-01-6 Trichloroethene 107

50 070108-87-2 Methylcyclohexane 115

50 06075-27-4 Dichlorobromomethane 113

50 09010061-01-5 cis-13-Dichloropropene 109

25 50108-10-1 4-Methyl-2-pentanone (MIBK) 111

50 075108-88-3 Toluene 106

50 1210061-02-6 trans-13-Dichloropropene 113

FORM I 8260B

10162012Page 124 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MS

Matrix e08985dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0027

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 09579-00-5 112-Trichloroethane 112

50 050127-18-4 Tetrachloroethene 110

25 25591-78-6 2-Hexanone 109

50 14106-93-4 12-Dibromoethane 116

50 055108-90-7 Chlorobenzene 107

15 181330-20-7 Xylenes Total 318

50 060100-42-5 Styrene 107

50 09575-25-2 Bromoform 115

50 04098-82-8 Isopropylbenzene 107

50 08079-34-5 1122-Tetrachloroethane 115

50 070541-73-1 13-Dichlorobenzene 106

50 12106-46-7 14-Dichlorobenzene 106

50 17120-82-1 124-Trichlorobenzene 110

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 125 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08985d Report Date 12-Oct-2012 0117

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08985dLab Smp Id 460-45537-C-2 MS Inj Date 12-OCT-2012 0027 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-C-2 MS5Misc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 10 QC Sample MSDil Factor 500000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 500000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 83204 173010 86

3 Chloromethane 50 1016 1016 (0283) 161645 203059 100

4 Vinyl Chloride 62 1022 1028 (0284) 141501 208792 100

6 Bromomethane 94 1181 1181 (0328) 84568 214819 110

5 Chloroethane 64 1236 1242 (0344) 73104 232055 120

7 Trichlorofluoromethane 101 1297 1303 (0361) 177163 242363 120

14 Freon TF 101 1571 1577 (0437) 100496 204542 100

15 11-Dichloroethene 96 1553 1553 (0432) 86070 216451 110

16 Acetone 58 1894 1894 (0527) 10416 197218 99

18 Carbon Disulfide 76 1565 1571 (0435) 366514 226264 110

27 Methyl Acetate 74 1961 1967 (0546) 18655 200164 100

22 Methylene Chloride 49 1857 1864 (0517) 178536 211689 100

28 MTBE 73 2016 2022 (0561) 376182 228747 110

25 trans-12-Dichloroethene 96 1949 1949 (0542) 109215 211677 100

30 11-Dichloroethane 63 2309 2309 (0642) 226749 207039 100

36 cis-12-Dichloroethene 96 2650 2656 (0737) 118569 210921 100

10162012Page 126 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08985d Report Date 12-Oct-2012 0117

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 19396 221710 110

42 Chloroform 83 2845 2845 (0791) 213034 216876 110

44 Cyclohexane 56 2784 2784 (0774) 180984 216238 110

43 111-Trichloroethane 97 2979 2985 (0829) 179996 206829 100

45 Carbon Tetrachloride 117 2930 2937 (0815) 145570 209299 100

48 Benzene 78 3260 3260 (0469) 482493 212344 110

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 369860 481613 48

49 12-Dichloroethane 62 3418 3418 (0951) 175178 213858 110

52 Fluorobenzene 96 3595 3601 (1000) 1234975 500000

54 Trichloroethene 95 3741 3741 (1041) 121196 214627 110

56 Methyl cyclohexane 83 3729 3729 (1037) 158792 229110 110

57 12-Dichloropropane 63 4192 4199 (1166) 132380 221450 110

68 Bromodichloromethane 83 4272 4272 (1188) 168703 225007 110

67 cis-13-Dichloropropene 75 4906 4912 (0705) 211819 218949 110

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 133223 221106 110

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1260222 494657 49

66 Toluene 91 5162 5162 (0742) 566751 211409 100

64 trans-13-Dichloropropene 75 5649 5649 (0812) 197737 226072 110

69 112-Trichloroethane 83 5820 5820 (0837) 91872 224994 110

71 Tetrachloroethene 166 5582 5582 (0803) 147320 220590 110

73 2-Hexanone 43 6674 6680 (0960) 100809 217957 110

74 Dibromochloromethane 129 6015 6021 (0865) 135240 231427 120

77 12-Dibromoethane 107 6259 6265 (0900) 117784 231222 120

78 Chlorobenzene-d5 117 6954 6954 (1000) 1102789 500000

79 Chlorobenzene 112 6972 6972 (1003) 391979 214069 110

81 Ethylbenzene 106 7064 7064 (1016) 207079 214786 110

82 m+p-Xylene 106 7277 7277 (1046) 521861 425705 210

84 o-Xylene 106 7856 7862 (1130) 254032 211187 100

85 Styrene 104 7942 7942 (1142) 433507 213222 110

86 Bromoform 173 7911 7911 (1138) 95433 230033 120

88 Isopropylbenzene 105 8350 8350 (1201) 635772 214844 110

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 518047 497030 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 151817 230609 120

105 13-Dichlorobenzene 146 10325 10331 (0987) 322106 211348 100

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 642491 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 334190 211356 100

111 12-Dichlorobenzene 146 11148 11148 (1065) 308704 214355 110

112 12-Dibromo-3-chloropropane 75 12233 12234 (1169) 26873 242889 120(R)

114 124-Trichlorobenzene 180 12977 12977 (1240) 177853 219597 110

M 120 12-Dichloroethene (Total) 100 227784 422599 210

M 121 Xylene (Total) 100 775893 636892 320

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 127 of 323

Data File e08985d

Date 12-OCT-2012 0027

Client ID Instrument VOAMS5i

Sample Info 460-45537-C-2 MS5 Operator GCMS VOAMS5

10162012Page 128 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MSD

Matrix e08986dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0051

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 03071-55-6 111-Trichloroethane 106

50 1175-71-8 Dichlorodifluoromethane 896

50 05074-87-3 Chloromethane 101

50 07075-01-4 Vinyl chloride 105

50 09074-83-9 Bromomethane 105

50 2096-12-8 12-Dibromo-3-Chloropropane 121

50 1195-50-1 12-Dichlorobenzene 111

50 07575-69-4 Trichlorofluoromethane 997

50 04575-35-4 11-Dichloroethene 119

50 04578-87-5 12-Dichloropropane 110

50 04076-13-1 112-Trichloro-122-trifluoroethane

111

25 1367-64-1 Acetone 101

50 06575-15-0 Carbon disulfide 119

10 1779-20-9 Methyl acetate 101

50 09075-09-2 Methylene Chloride 106

50 065156-60-5 trans-12-Dichloroethene 108

50 10124-48-1 Chlorodibromomethane 118

50 0701634-04-4 Methyl tert-butyl ether 116

50 08575-00-3 Chloroethane 105

50 06575-34-3 11-Dichloroethane 111

50 090156-59-2 cis-12-Dichloroethene 109

25 1278-93-3 2-Butanone (MEK) 114

50 04067-66-3 Chloroform 113

50 050100-41-4 Ethylbenzene 111

50 080110-82-7 Cyclohexane 117

50 03056-23-5 Carbon tetrachloride 110

50 04071-43-2 Benzene 114

50 095107-06-2 12-Dichloroethane 109

50 04579-01-6 Trichloroethene 113

50 070108-87-2 Methylcyclohexane 121

50 06075-27-4 Dichlorobromomethane 116

50 09010061-01-5 cis-13-Dichloropropene 115

25 50108-10-1 4-Methyl-2-pentanone (MIBK) 114

50 075108-88-3 Toluene 111

50 1210061-02-6 trans-13-Dichloropropene 119

FORM I 8260B

10162012Page 129 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MSD

Matrix e08986dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0051

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 09579-00-5 112-Trichloroethane 116

50 050127-18-4 Tetrachloroethene 116

25 25591-78-6 2-Hexanone 111

50 14106-93-4 12-Dibromoethane 117

50 055108-90-7 Chlorobenzene 111

15 181330-20-7 Xylenes Total 329

50 060100-42-5 Styrene 110

50 09575-25-2 Bromoform 114

50 04098-82-8 Isopropylbenzene 111

50 08079-34-5 1122-Tetrachloroethane 116

50 070541-73-1 13-Dichlorobenzene 110

50 12106-46-7 14-Dichlorobenzene 110

50 17120-82-1 124-Trichlorobenzene 119

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

97 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 130 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08986d Report Date 12-Oct-2012 0118

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08986dLab Smp Id 460-45537-C-2 MSD Inj Date 12-OCT-2012 0051 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-C-2 MSD5Misc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 11 QC Sample MSDDil Factor 500000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 500000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 90471 179208 90

3 Chloromethane 50 1016 1016 (0283) 169425 202751 100

4 Vinyl Chloride 62 1022 1028 (0284) 149176 209689 100

6 Bromomethane 94 1181 1181 (0328) 86595 209548 100

5 Chloroethane 64 1236 1242 (0344) 69668 210673 100

7 Trichlorofluoromethane 101 1297 1303 (0361) 152935 199307 100

14 Freon TF 101 1565 1577 (0435) 114134 221294 110

15 11-Dichloroethene 96 1547 1553 (0430) 98966 237094 120

16 Acetone 58 1900 1894 (0529) 11165 201386 100

18 Carbon Disulfide 76 1565 1571 (0435) 405349 238385 120

27 Methyl Acetate 74 1961 1967 (0546) 19684 201192 100

22 Methylene Chloride 49 1858 1864 (0517) 187993 212342 110

28 MTBE 73 2022 2022 (0562) 399850 231621 120(R)

25 trans-12-Dichloroethene 96 1943 1949 (0540) 117162 216323 110

30 11-Dichloroethane 63 2309 2309 (0642) 255983 222660 110

36 cis-12-Dichloroethene 96 2650 2656 (0737) 129220 218978 110

10162012Page 131 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08986d Report Date 12-Oct-2012 0118

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 20938 227991 110

42 Chloroform 83 2845 2845 (0791) 233404 226357 110

44 Cyclohexane 56 2778 2784 (0773) 204751 233046 120

43 111-Trichloroethane 97 2979 2985 (0829) 194508 212915 110

45 Carbon Tetrachloride 117 2931 2937 (0815) 161111 220670 110

48 Benzene 78 3260 3260 (0469) 525066 227601 110

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 386156 479012 48

49 12-Dichloroethane 62 3412 3418 (0949) 188223 218898 110

52 Fluorobenzene 96 3595 3601 (1000) 1296388 500000

54 Trichloroethene 95 3741 3741 (1041) 133629 225434 110

56 Methyl cyclohexane 83 3723 3729 (1036) 175741 241553 120

57 12-Dichloropropane 63 4192 4199 (1166) 138376 220515 110

68 Bromodichloromethane 83 4272 4272 (1188) 182026 231276 120

67 cis-13-Dichloropropene 75 4906 4912 (0705) 226245 230339 120

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 139423 227913 110

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1279885 494812 49

66 Toluene 91 5162 5162 (0742) 602122 221221 110

64 trans-13-Dichloropropene 75 5650 5649 (0812) 211878 238592 120(R)

69 112-Trichloroethane 83 5820 5820 (0837) 95786 231047 120

71 Tetrachloroethene 166 5582 5582 (0803) 157152 231769 120

73 2-Hexanone 43 6680 6680 (0961) 103997 221464 110

74 Dibromochloromethane 129 6015 6021 (0865) 140562 236912 120

77 12-Dibromoethane 107 6259 6265 (0900) 120913 233791 120

78 Chlorobenzene-d5 117 6954 6954 (1000) 1119645 500000

79 Chlorobenzene 112 6972 6972 (1003) 411739 221475 110

81 Ethylbenzene 106 7064 7064 (1016) 216984 221672 110

82 m+p-Xylene 106 7277 7277 (1046) 549474 441482 220

84 o-Xylene 106 7856 7862 (1130) 265488 217389 110

85 Styrene 104 7942 7942 (1142) 452927 219420 110

86 Bromoform 173 7911 7911 (1138) 96039 228008 110

88 Isopropylbenzene 105 8344 8350 (1200) 668990 222665 110

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 517679 487311 49

92 1122-Tetrachloroethane 83 9112 9112 (0871) 155509 231763 120

105 13-Dichlorobenzene 146 10325 10331 (0987) 342279 220349 110

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 654839 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 355256 220442 110

111 12-Dichlorobenzene 146 11148 11148 (1065) 324646 221173 110

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 27355 242581 120(R)

114 124-Trichlorobenzene 180 12977 12977 (1240) 196651 238228 120

M 120 12-Dichloroethene (Total) 100 246382 435302 220

M 121 Xylene (Total) 100 814963 658871 330

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 132 of 323

Data File e08986d

Date 12-OCT-2012 0051

Client ID Instrument VOAMS5i

Sample Info 460-45537-C-2 MSD5 Operator GCMS VOAMS5

10162012Page 133 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GCMS VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

VOAMS5

128076

Start Date

End Date 09172012 1616

09172012 0324

BFB 460-1280761 Rtx-VMS 018(mm)109172012 0324 e07834d

IC 460-1280762 Rtx-VMS 018(mm)109172012 0449 e07836d

IC 460-1280763 Rtx-VMS 018(mm)109172012 0536 e07838d

ICIS 460-1280764 Rtx-VMS 018(mm)109172012 0600 e07839d

IC 460-1280765 Rtx-VMS 018(mm)109172012 0623 e07840d

IC 460-1280766 Rtx-VMS 018(mm)109172012 0646 e07841d

IC 460-1280767 Rtx-VMS 018(mm)109172012 0710 e07842d

ZZZZZ Rtx-VMS 018(mm)109172012 0937

ZZZZZ Rtx-VMS 018(mm)109172012 1047

ZZZZZ Rtx-VMS 018(mm)109172012 1111

ZZZZZ Rtx-VMS 018(mm)109172012 1134

ZZZZZ Rtx-VMS 018(mm)109172012 1157

ZZZZZ Rtx-VMS 018(mm)509172012 1221

ZZZZZ Rtx-VMS 018(mm)509172012 1244

ZZZZZ Rtx-VMS 018(mm)109172012 1307

ZZZZZ Rtx-VMS 018(mm)109172012 1331

ZZZZZ Rtx-VMS 018(mm)109172012 1354

ZZZZZ Rtx-VMS 018(mm)109172012 1417

ZZZZZ Rtx-VMS 018(mm)109172012 1441

CCV 460-12807620 Rtx-VMS 018(mm)109172012 1616

8260B

10162012Page 134 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GCMS VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

VOAMS5

131656

Start Date

End Date 10122012 0114

10112012 2008

BFB 460-1316561 Rtx-VMS 018(mm)110112012 2008 e08975d

CCVIS 460-1316562 Rtx-VMS 018(mm)110112012 2050 e08976d

LCS 460-1316563 Rtx-VMS 018(mm)110112012 2113 e08977d

MB 460-1316564 Rtx-VMS 018(mm)110112012 2247 e08981d

460-45537-3 TB-17338-100512-253 Rtx-VMS 018(mm)110112012 2317 e08982d

460-45537-1 WC-17338-100512-MW14-MM-251

Rtx-VMS 018(mm)110112012 2341 e08983d

460-45537-2 WC-17338-100512-MW101-MM-252

Rtx-VMS 018(mm)110122012 0004 e08984d

460-45537-2 MS WC-17338-100512-MW101-MM-252 MS

Rtx-VMS 018(mm)510122012 0027 e08985d

460-45537-2 MSD WC-17338-100512-MW101-MM-252 MSD

Rtx-VMS 018(mm)510122012 0051 e08986d

CCV 460-13165610 Rtx-VMS 018(mm)110122012 0114 e08987d

8260B

10162012Page 135 of 323

10162012Page 136 of 323

10162012Page 137 of 323

10162012Page 138 of 323

10162012Page 139 of 323

Method 8082 -

DelawarePolychlorinated Biphenyls (PCBs)

(GC) by Method 8082 (Delaware)

10162012Page 140 of 323

FORM II

GC SEMI VOA SURROGATE RECOVERY

Lab Name Job No 460-45537-1

SDG No

Matrix Water Level Low

TestAmerica Edison

GC Column (1) ID (mm) GC Column (2) ID (mm)CLP-1 053 CLP-2 053

Lab Sample IDClient Sample ID DCB1 DCB2

460-45537-1WC-17338-100512-MW14-MM-251

82 83

460-45537-2WC-17338-100512-MW101-MM-252

52 50

MB 460-1309971-A

97 88

LCS 460-1309972-A

91 84

LCSD 460-1309973-A

108 99

QC LIMITSQC LIMITSDCB = DCB Decachlorobiphenyl 37-150

FORM II 8082

Column to be used to flag recovery values

10162012Page 141 of 323

GC SEMI VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vf479497dWater

Lab ID LCS 460-1309972-A Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

PCB-1016 500 507 71-126101

PCB-1260 500 557 73-130111

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 142 of 323

GC SEMI VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vr479497dWater

Lab ID LCS 460-1309972-A Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

PCB-1016 500 483 71-12697

PCB-1260 500 573 73-130115

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 143 of 323

GC SEMI VOA LAB CONTROL SAMPLE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vf479498dWater

Lab ID LCSD 460-1309973-A Client ID

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

LCSD LCSD

500 516 30 71-126PCB-1016 2103

500 583 30 73-130PCB-1260 5117

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 144 of 323

GC SEMI VOA LAB CONTROL SAMPLE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vr479498dWater

Lab ID LCSD 460-1309973-A Client ID

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

LCSD LCSD

500 497 30 71-126PCB-1016 399

500 595 30 73-130PCB-1260 4119

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 145 of 323

FORM IV

GC SEMI VOA METHOD BLANK SUMMARY

Lab Name

SDG No

Job No 460-45537-1TestAmerica Edison

Date Analyzed(1)

Instrument ID(1)

GC Column(1) ID

Instrument ID(2)

Date Extracted 10082012 0755

Date Analyzed(2)

GC Column(2) IDCLP-2053(mm) 053(mm)

PESTGC9

10082012 2208

Lab File ID(1) Lab File ID(2)

Matrix Water

vf479496d

Lab Sample ID MB 460-1309971-A

vr479496d

10082012 2208

PESTGC9

CLP-1

THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES

ANALYZED 2

DATEDATE

ANALYZED 1LAB SAMPLE IDCLIENT SAMPLE ID

LCS 460-1309972-A 10082012 2224 10082012 2224

LCSD 460-1309973-A 10082012 2239 10082012 2239

460-45537-1WC-17338-100512-MW14-MM-251

10092012 0029 10092012 0029

460-45537-2WC-17338-100512-MW101-MM-252

10092012 0045 10092012 0045

FORM IV 8082

10162012Page 146 of 323

GC SEMI VOA ANALYTICAL SEQUENCE

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVRT 460-1311372 Date Analyzed 10082012 1830

Lab File ID (Standard) vf479493d

Instrument ID PESTGC9 GC Column CLP-2 ID 053(mm)

Heated Purge (YN) N

Calibration ID 17840

THE ANALYTICAL SEQUENCE OF BLANKS SAMPLES STANDARDS MSMSDs AND LCSs IS GIVEN BELOW

RT

DCB

UPPER LIMIT

LOWER LIMIT

1159

1139

CONTINUING CALIBRATION SURROGATE 1149

LAB SAMPLE ID DATE ANALYZEDCLIENT SAMPLE ID LAB FILE ID

CCVRT 460-1311372 10082012 1830 1149vf479493d

MB 460-1309971-A 10082012 2208 1148vf479496d

LCS 460-1309972-A 10082012 2224 1148vf479497d

LCSD 460-1309973-A 10082012 2239 1148vf479498d

460-45537-1 10092012 0029 1149WC-17338-100512-MW14-MM-251

vf479505d

460-45537-2 10092012 0045 1149WC-17338-100512-MW101-MM-252

vf479506d

PIBLK 460-13113718 10092012 0131 1149vf479509d

CCV 460-13113719 10092012 0147 1149vf479510d

DCB = DCB Decachlorobiphenyl

DCB RT Limit = plusmn 01 minutes of surrogate RT

Column used to flag values outside QC limits

FORM VIII 8082

10162012Page 147 of 323

GC SEMI VOA ANALYTICAL SEQUENCE

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVRT 460-1311372 Date Analyzed 10082012 1830

Lab File ID (Standard) vr479493d

Instrument ID PESTGC9 GC Column CLP-1 ID 053(mm)

Heated Purge (YN) N

Calibration ID 17839

THE ANALYTICAL SEQUENCE OF BLANKS SAMPLES STANDARDS MSMSDs AND LCSs IS GIVEN BELOW

RT

DCB

UPPER LIMIT

LOWER LIMIT

1071

1051

CONTINUING CALIBRATION SURROGATE 1061

LAB SAMPLE ID DATE ANALYZEDCLIENT SAMPLE ID LAB FILE ID

CCVRT 460-1311372 10082012 1830 1061vr479493d

MB 460-1309971-A 10082012 2208 1061vr479496d

LCS 460-1309972-A 10082012 2224 1061vr479497d

LCSD 460-1309973-A 10082012 2239 1061vr479498d

460-45537-1 10092012 0029 1061WC-17338-100512-MW14-MM-251

vr479505d

460-45537-2 10092012 0045 1061WC-17338-100512-MW101-MM-252

vr479506d

PIBLK 460-13113718 10092012 0131 1061vr479509d

CCV 460-13113719 10092012 0147 1061vr479510d

DCB = DCB Decachlorobiphenyl

DCB RT Limit = plusmn 01 minutes of surrogate RT

Column used to flag values outside QC limits

FORM VIII 8082

10162012Page 148 of 323

FORM XForm 1

Client Sample ID

Lab Name Job No

SDG No

Lab Sample ID LCS 460-1309972-A

Instrument ID (1) Instrument ID (2)

Date Analyzed (1) Date Analyzed (2)

GC Column (1) ID GC Column (2) ID

TestAmerica Edison 460-45537-1

IDENTIFICATION SUMMARYForm 1

053(mm) 053(mm)

10082012 2224 10082012 2224

PESTGC9 PESTGC9

CLP-1 CLP-2

ANALYTE COL PEAK RTRT WINDOW

FROM TO PEAK MEAN

CONCENTRATIONRPD

PCB-1016 1 1 206 201 215 473 483 47

2 250 246 260 494

3 275 271 285 530

4 310 306 320 501

5 330 326 340 520

6 369 361 375 302

7 401 397 411 541

8 419 412 426 505

2 1 293 289 303 525 507

2 360 357 371 562

3 404 401 415 567

4 444 441 455 558

5 468 465 479 594

6 518 509 523 402

7 557 547 561 259

8 571 568 582 584

PCB-1260 1 1 605 600 614 554 573 28

2 650 645 659 558

3 694 689 703 581

4 714 709 723 548

5 758 753 767 565

6 886 882 896 559

7 908 904 918 619

8 1014 1008 1022 600

2 1 771 769 783 600 557

2 817 814 828 594

3 903 901 915 625

4 928 926 940 622

5 941 938 952 643

6 986 983 997 612

7 1062 1055 1069 212

8 1106 1102 1116 550

FORM X 8082

10162012Page 149 of 323

FORM XForm 1

Client Sample ID

Lab Name Job No

SDG No

Lab Sample ID LCSD 460-1309973-A

Instrument ID (1) Instrument ID (2)

Date Analyzed (1) Date Analyzed (2)

GC Column (1) ID GC Column (2) ID

TestAmerica Edison 460-45537-1

IDENTIFICATION SUMMARYForm 1

053(mm) 053(mm)

10082012 2239 10082012 2239

PESTGC9 PESTGC9

CLP-1 CLP-2

ANALYTE COL PEAK RTRT WINDOW

FROM TO PEAK MEAN

CONCENTRATIONRPD

PCB-1016 1 1 206 201 215 483 497 38

2 250 246 260 505

3 275 271 285 542

4 310 306 320 510

5 330 326 340 529

6 368 361 375 369

7 401 397 411 549

8 419 412 426 491

2 1 292 289 303 535 516

2 359 357 371 574

3 404 401 415 572

4 443 441 455 572

5 468 465 479 606

6 518 509 523 407

7 557 547 561 267

8 571 568 582 599

PCB-1260 1 1 605 600 614 565 595 19

2 650 645 659 571

3 694 689 703 595

4 714 709 723 563

5 757 753 767 585

6 886 882 896 582

7 908 904 918 656

8 1014 1008 1022 639

2 1 771 769 783 615 583

2 816 814 828 610

3 902 901 915 645

4 928 926 940 648

5 940 938 952 669

6 986 983 997 637

7 1062 1055 1069 253

8 1106 1102 1116 590

FORM X 8082

10162012Page 150 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix vf479505dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1000

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0029

5(mL)

Sample wtvol 980(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

83 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 151 of 323

Data File vf479505d Report Date 09-Oct-2012 0313

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479505dLab Smp Id 460-45537-E-1-B Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0029 Operator Inst ID PESTGC9iSmp Info 460-45537-E-1-BMisc Info 460-45537-E-1-BComment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 35 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 98000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11489 11515 -0026 22061081 829479 042 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 152 of 323

Data File vf479505d

Date 09-OCT-2012 0029

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-1-B Operator

10162012Page 153 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix vr479505dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1000

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0029

5(mL)

Sample wtvol 980(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

051 013U12674-11-2 PCB-1016 013

051 029U11104-28-2 PCB-1221 029

051 012U11141-16-5 PCB-1232 012

051 012U53469-21-9 PCB-1242 012

051 024U12672-29-6 PCB-1248 024

051 017U11097-69-1 PCB-1254 017

051 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

82 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 154 of 323

Data File vr479505d Report Date 09-Oct-2012 0303

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479505dLab Smp Id 460-45537-E-1-B Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0029 Operator Inst ID PESTGC9iSmp Info 460-45537-E-1-BMisc Info 460-45537-E-1-BComment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 35 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 98000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 38407031 815954 042 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 155 of 323

Data File vr479505d

Date 09-OCT-2012 0029

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-1-B Operator

10162012Page 156 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix vf479506dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1230

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0045

5(mL)

Sample wtvol 990(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

50 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 157 of 323

Data File vf479506d Report Date 09-Oct-2012 0322

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479506dLab Smp Id 460-45537-E-2-A Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0045 Operator Inst ID PESTGC9iSmp Info 460-45537-E-2-AMisc Info 460-45537-E-2-AComment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 36 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 99000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11487 11515 -0028 13346591 501821 025 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 158 of 323

Data File vf479506d

Date 09-OCT-2012 0045

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-2-A Operator

10162012Page 159 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix vr479506dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1230

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0045

5(mL)

Sample wtvol 990(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

051 013U12674-11-2 PCB-1016 013

051 028U11104-28-2 PCB-1221 028

051 012U11141-16-5 PCB-1232 012

051 012U53469-21-9 PCB-1242 012

051 024U12672-29-6 PCB-1248 024

051 017U11097-69-1 PCB-1254 017

051 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

52 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 160 of 323

Data File vr479506d Page 1 Report Date 09-Oct-2012 0322

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479506dLab Smp Id 460-45537-E-2-A Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0045 Operator Inst ID PESTGC9iSmp Info 460-45537-E-2-AMisc Info 460-45537-E-2-AComment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 36 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 99000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 24675227 524223 026 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 161 of 323

Data File vr479506d

Date 09-OCT-2012 0045

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-2-A Operator

10162012Page 162 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vf479200dLevel 2 IC 460-1299268 vf479201dLevel 3 IC 460-1299269 vf479202dLevel 4 IC 460-12992610 vf479203dLevel 5 IC 460-12992611 vf479204d

ANALYTE LVL 1 LVL 2 LVL 3 LVL 4 LVL 5 AVG RTRT WINDOW

PCB-1016 Peak 1 29602891 - 30312960 2960 2961 2959 2959PCB-1016 Peak 2 36403571 - 37113640 3640 3641 3639 3640PCB-1016 Peak 3 40844015 - 41554084 4084 4085 4083 4083PCB-1016 Peak 4 44774409 - 45494477 4477 4479 4477 4476PCB-1016 Peak 5 47224652 - 47924722 4722 4722 4722 4722PCB-1016 Peak 6 51575088 - 52285157 5158 5158 5157 5157PCB-1016 Peak 7 55425472 - 56125542 5543 5542 5542 5542PCB-1016 Peak 8 57515682 - 58225751 5751 5752 5751 5751PCB-1260 Peak 1 77567686 - 78267756 7756 7756 7756 7755PCB-1260 Peak 2 82158145 - 82858216 8215 8215 8215 8215PCB-1260 Peak 3 90839014 - 91549084 9084 9084 9083 9082PCB-1260 Peak 4 93329262 - 94029332 9332 9332 9332 9331PCB-1260 Peak 5 94549384 - 95249454 9454 9454 9454 9453PCB-1260 Peak 6 99019831 - 99719901 9901 9901 9901 9901PCB-1260 Peak 7 1061710546 - 1068610617 10617 10616 10617 10616PCB-1260 Peak 8 1108611016 - 1115611087 11087 11086 11084 11085DCB Decachlorobiphenyl 1151511415 - 1161511518 11520 11515 11510 11512

FORM VI 8082 10162012Page 163 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1299267 vf479200d2Level IC 460-1299268 vf479201d3Level IC 460-1299269 vf479202d4Level IC 460-12992610 vf479203d5Level IC 460-12992611 vf479204d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1016 Peak 1 Ave 155 20012858 10484 96475 9762186122

102726535

PCB-1016 Peak 2 Ave 122 20025248 21181 20808 2014318185

211130015

PCB-1016 Peak 3 Ave 124 20010359 90007 83526 8441074163

871400841

PCB-1016 Peak 4 Ave 130 20045579 38951 35291 3591632814

377100165

PCB-1016 Peak 5 Ave 129 20019485 17677 14821 1595214340

164548979

PCB-1016 Peak 6 Ave 171 20012410 10306 89543 9039281426

977025128

PCB-1016 Peak 7 Ave 161 20015097 12427 11165 1121510046

119900052

PCB-1016 Peak 8 Ave 121 20014456 12522 11609 1161310532

121463746

PCB-1260 Peak 1 Ave 165 20028165 22320 20852 2059718598

221063931

PCB-1260 Peak 2 Ave 173 20032398 25230 23518 2315121164

250922627

PCB-1260 Peak 3 Ave 101 20042792 37584 35706 3549332757

368665853

PCB-1260 Peak 4 Ave 114 20019125 16727 15681 1547514194

162405856

PCB-1260 Peak 5 Ave 71 20097407 90339 86445 8609680436

881445133

PCB-1260 Peak 6 Ave 116 20020218 16837 16387 1620514980

169255417

PCB-1260 Peak 7 Ave 115 20025044 20516 20530 2080218426

210635761

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 164 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1260 Peak 8 Ave 114 20092729 80982 75320 7482969000

785718832

DCB Decachlorobiphenyl Ave 104 200306013 281530 257456 246481238335

265963086

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 165 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vf479200dLevel 2 IC 460-1299268 vf479201dLevel 3 IC 460-1299269 vf479202dLevel 4 IC 460-12992610 vf479203dLevel 5 IC 460-12992611 vf479204d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1LVL 2 LVL 2LVL 3 LVL 3LVL 4 LVL 4LVL 5 LVL 5

PCB-1016 Peak 1 Ave 1285777 5241842 9647477 14643185 21530533 100 500 1000 1500 2500PCB-1016 Peak 2 Ave 2524804 10590544 20808307 30213965 45462323 100 500 1000 1500 2500PCB-1016 Peak 3 Ave 1035943 4500373 8352607 12661468 18540701 100 500 1000 1500 2500PCB-1016 Peak 4 Ave 4557926 19475271 35290615 53874092 82034010 100 500 1000 1500 2500PCB-1016 Peak 5 Ave 1948484 8838480 14821328 23927783 35848765 100 500 1000 1500 2500PCB-1016 Peak 6 Ave 1240957 5152808 8954270 13558761 20356566 100 500 1000 1500 2500PCB-1016 Peak 7 Ave 1509707 6213265 11165134 16822458 25115800 100 500 1000 1500 2500PCB-1016 Peak 8 Ave 1445572 6260864 11609452 17418946 26330856 100 500 1000 1500 2500PCB-1260 Peak 1 Ave 2816529 11159859 20851674 30895442 46495806 100 500 1000 1500 2500PCB-1260 Peak 2 Ave 3239811 12615093 23518487 34726449 52908911 100 500 1000 1500 2500PCB-1260 Peak 3 Ave 4279245 18792136 35705636 53240044 81893015 100 500 1000 1500 2500PCB-1260 Peak 4 Ave 1912505 8363664 15681452 23213228 35484032 100 500 1000 1500 2500PCB-1260 Peak 5 Ave 974074 4516956 8644462 12914338 20108960 100 500 1000 1500 2500PCB-1260 Peak 6 Ave 2021814 8418625 16386843 24307809 37450674 100 500 1000 1500 2500PCB-1260 Peak 7 Ave 2504445 10257895 20530020 31202581 46064749 100 500 1000 1500 2500PCB-1260 Peak 8 Ave 927285 4049088 7531982 11224374 17250044 100 500 1000 1500 2500DCB Decachlorobiphenyl Ave 7650320 14076513 25745578 36972164 47667099 250 500 100 150 200

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 166 of 323

Data File vf479200d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479200dLab Smp Id IC-SG1660L1_00013 Inj Date 30-SEP-2012 1704 Operator Inst ID PESTGC9iSmp Info ic-SG1660L1_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1704 Cal File vf479200dAls bottle 7 Calibration Sample Level 1Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2960 2961 -0001 1285777 100000 120 8000- 12000 10000

3640 3641 -0001 2524804 100000 120 15709- 23564 19636

4084 4085 -0001 1035943 100000 120 6446- 9668 8057

4477 4479 -0002 4557926 100000 120 28359- 42539 35449

4722 4722 0000 1948484 100000 120 12123- 18185 15154

5157 5158 -0001 1240957 100000 130 7721- 11582 9651

5542 5542 0000 1509707 100000 120 9393- 14090 11742

5751 5752 -0001 1445572 100000 120 8994- 13491 11243

Average of Peak Amounts = 122

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 2816529 100000 130 8000- 12000 10000(M)

10162012Page 167 of 323

Data File vf479200d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8216 8215 0001 3239811 100000 130 9202- 13803 11503

9084 9084 0000 4279245 100000 120 12155- 18232 15193

9332 9332 0000 1912505 100000 120 5432- 8148 6790

9454 9454 0000 974074 100000 110 2767- 4150 3458

9901 9901 0000 2021814 100000 120 5743- 8614 7178

10617 10616 0001 2504445 100000 120 7114- 10670 8892

11087 11086 0001 927285 100000 120 2634- 3951 3292

Average of Peak Amounts = 120

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11518 11515 0003 7650320 250000 29 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 168 of 323

Data File vf479200d

Date 30-SEP-2012 1704

Client ID Instrument PESTGC9i

Sample Info ic-SG1660L1_00013 Operator

10162012Page 169 of 323

Data File vf479201d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479201dLab Smp Id IC-SG1660L2_00013 Inj Date 30-SEP-2012 1720 Operator Inst ID PESTGC9iSmp Info SG1660L2_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1720 Cal File vf479201dAls bottle 8 Calibration Sample Level 2Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2960 2961 -0001 5241842 500000 510 8000- 12000 10000

3640 3641 -0001 10590544 500000 500 16163- 24245 20204

4084 4085 -0001 4500373 500000 520 6868- 10303 8585

4477 4479 -0002 19475271 500000 520 29723- 44584 37153

4722 4722 0000 8838480 500000 540 13489- 20234 16861

5158 5158 0000 5152808 500000 530 7864- 11796 9830

5543 5542 0001 6213265 500000 520 9483- 14224 11853

5751 5752 -0001 6260864 500000 520 9555- 14333 11944

Average of Peak Amounts = 518

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 11159859 500000 500 8000- 12000 10000(M)

10162012Page 170 of 323

Data File vf479201d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 12615093 500000 500 9043- 13565 11304

9084 9084 0000 18792136 500000 510 13471- 20207 16839

9332 9332 0000 8363664 500000 510 5996- 8993 7494

9454 9454 0000 4516956 500000 510 3238- 4857 4048

9901 9901 0000 8418625 500000 500 6035- 9052 7544

10617 10616 0001 10257895 500000 490 7353- 11030 9192

11087 11086 0001 4049088 500000 520 2903- 4354 3628

Average of Peak Amounts = 506

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11520 11515 0005 14076513 500000 53 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 171 of 323

Data File vf479201d

Date 30-SEP-2012 1720

Client ID Instrument PESTGC9i

Sample Info SG1660L2_00013 Operator

10162012Page 172 of 323

Data File vf479202d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479202dLab Smp Id IC-SG1660L3_00019 Inj Date 30-SEP-2012 1735 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 9 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2961 2961 0000 9647477 100000 940 8000- 12000 10000

3641 3641 0000 20808307 100000 980 17255- 25882 21569

4085 4085 0000 8352607 100000 960 6926- 10389 8658

4479 4479 0000 35290615 100000 940 29264- 43896 36580

4722 4722 0000 14821328 100000 900 12290- 18435 15363

5158 5158 0000 8954270 100000 920 7425- 11138 9281

5542 5542 0000 11165134 100000 930 9258- 13888 11573

5752 5752 0000 11609452 100000 960 9627- 14440 12034

Average of Peak Amounts = 940

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 20851674 100000 940 8000- 12000 10000(M)

10162012Page 173 of 323

Data File vf479202d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 23518487 100000 940 9023- 13535 11279

9084 9084 0000 35705636 100000 970 13699- 20548 17124

9332 9332 0000 15681452 100000 960 6016- 9025 7520

9454 9454 0000 8644462 100000 980 3317- 4975 4146

9901 9901 0000 16386843 100000 970 6287- 9431 7859

10616 10616 0000 20530020 100000 970 7877- 11815 9846

11086 11086 0000 7531982 100000 960 2890- 4335 3612

Average of Peak Amounts = 962

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11515 11515 0000 25745578 100000 97 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 174 of 323

Data File vf479202d

Date 30-SEP-2012 1735

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 175 of 323

Data File vf479203d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479203dLab Smp Id IC-SG1660L4_00013 Inj Date 30-SEP-2012 1751 Operator Inst ID PESTGC9iSmp Info SG1660L4_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1751 Cal File vf479203dAls bottle 10 Calibration Sample Level 4Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2959 2961 -0002 14643185 150000 1400 8000- 12000 10000

3639 3641 -0002 30213965 150000 1400 16507- 24760 20633

4083 4085 -0002 12661468 150000 1400 6917- 10376 8647

4477 4479 -0002 53874092 150000 1400 29433- 44149 36791

4722 4722 0000 23927783 150000 1400 13072- 19609 16341

5157 5158 -0001 13558761 150000 1400 7408- 11111 9259

5542 5542 0000 16822458 150000 1400 9191- 13786 11488

5751 5752 -0001 17418946 150000 1400 9516- 14275 11896

Average of Peak Amounts = 143e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 30895442 150000 1400 8000- 12000 10000(M)

10162012Page 176 of 323

Data File vf479203d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 34726449 150000 1400 8992- 13488 11240

9083 9084 -0001 53240044 150000 1400 13786- 20679 17232

9332 9332 0000 23213228 150000 1400 6011- 9016 7513

9454 9454 0000 12914338 150000 1500 3344- 5016 4180

9901 9901 0000 24307809 150000 1400 6294- 9441 7868

10617 10616 0001 31202581 150000 1500 8080- 12119 10099

11084 11086 -0002 11224374 150000 1400 2906- 4360 3633

Average of Peak Amounts = 143e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11510 11515 -0005 36972164 150000 140 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 177 of 323

Data File vf479203d

Date 30-SEP-2012 1751

Client ID Instrument PESTGC9i

Sample Info SG1660L4_00013 Operator

10162012Page 178 of 323

Data File vf479204d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479204dLab Smp Id IC-SG1660L5_00013 Inj Date 30-SEP-2012 1807 Operator Inst ID PESTGC9iSmp Info SG1660L5_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1807 Cal File vf479204dAls bottle 11 Calibration Sample Level 5Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2959 2961 -0002 21530533 250000 2100 8000- 12000 10000

3640 3641 -0001 45462323 250000 2200 16892- 25338 21115

4083 4085 -0002 18540701 250000 2100 6889- 10334 8611

4476 4479 -0003 82034010 250000 2200 30481- 45721 38101

4722 4722 0000 35848765 250000 2200 13320- 19980 16650

5157 5158 -0001 20356566 250000 2100 7564- 11346 9455

5542 5542 0000 25115800 250000 2100 9332- 13998 11665

5751 5752 -0001 26330856 250000 2200 9784- 14675 12230

Average of Peak Amounts = 213e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7755 7756 -0001 46495806 250000 2100 8000- 12000 10000(M)

10162012Page 179 of 323

Data File vf479204d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 52908911 250000 2100 9103- 13655 11379

9082 9084 -0002 81893015 250000 2200 14090- 21136 17613

9331 9332 -0001 35484032 250000 2200 6105- 9158 7632

9453 9454 -0001 20108960 250000 2300 3460- 5190 4325

9901 9901 0000 37450674 250000 2200 6444- 9666 8055

10616 10616 0000 46064749 250000 2200 7926- 11889 9907

11085 11086 -0001 17250044 250000 2200 2968- 4452 3710

Average of Peak Amounts = 219e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11512 11515 -0003 47667099 200000 180 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 180 of 323

Data File vf479204d

Date 30-SEP-2012 1807

Client ID Instrument PESTGC9i

Sample Info SG1660L5_00013 Operator

10162012Page 181 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vr479200dLevel 2 IC 460-1299268 vr479201dLevel 3 IC 460-1299269 vr479202dLevel 4 IC 460-12992610 vr479203dLevel 5 IC 460-12992611 vr479204d

ANALYTE LVL 1 LVL 2 LVL 3 LVL 4 LVL 5 AVG RTRT WINDOW

PCB-1016 Peak 1 20842015 - 21552085 2084 2085 2083 2084PCB-1016 Peak 2 25272457 - 25972527 2526 2527 2527 2526PCB-1016 Peak 3 27762707 - 28472777 2776 2777 2775 2775PCB-1016 Peak 4 31283060 - 32003128 3128 3130 3128 3127PCB-1016 Peak 5 33293260 - 34003329 3329 3330 3328 3328PCB-1016 Peak 6 36823615 - 37553682 3682 3685 3683 3681PCB-1016 Peak 7 40433973 - 41134042 4043 4043 4042 4043PCB-1016 Peak 8 41904121 - 42614190 4190 4191 4188 4190PCB-1260 Peak 1 60716002 - 61426072 6072 6072 6071 6071PCB-1260 Peak 2 65226452 - 65926522 6523 6522 6522 6521PCB-1260 Peak 3 69646894 - 70346964 6965 6964 6963 6964PCB-1260 Peak 4 71647095 - 72357165 7165 7165 7164 7164PCB-1260 Peak 5 76027532 - 76727602 7603 7602 7602 7601PCB-1260 Peak 6 88938823 - 89638893 8894 8893 8893 8892PCB-1260 Peak 7 91159045 - 91859115 9115 9115 9115 9114PCB-1260 Peak 8 1015310083 - 1022310153 10154 10153 10153 10153DCB Decachlorobiphenyl 1062410524 - 1072410625 10625 10624 10624 10624

FORM VI 8082 10162012Page 182 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1299267 vr479200d2Level IC 460-1299268 vr479201d3Level IC 460-1299269 vr479202d4Level IC 460-12992610 vr479203d5Level IC 460-12992611 vr479204d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1016 Peak 1 Ave 197 20021391 15827 14690 1421213626

159493236

PCB-1016 Peak 2 Ave 165 20034434 28377 25503 2514722693

272309984

PCB-1016 Peak 3 Ave 77 20020149 18502 16986 1713716990

179529604

PCB-1016 Peak 4 Ave 163 20075334 61344 55787 5498850020

594947119

PCB-1016 Peak 5 Ave 111 20026774 23733 21963 2197020028

228936643

PCB-1016 Peak 6 Ave 186 20030865 24479 22517 2109919526

236972316

PCB-1016 Peak 7 Ave 97 20025842 23012 21540 2153920131

224127747

PCB-1016 Peak 8 Ave 151 20012619 94689 86303 1057294995

101578271

PCB-1260 Peak 1 Ave 163 20041532 33110 31025 3015327565

326771001

PCB-1260 Peak 2 Ave 177 20078411 60909 57128 5539650491

604671657

PCB-1260 Peak 3 Ave 138 20068452 55082 53236 5187948612

554520757

PCB-1260 Peak 4 Ave 154 20037971 30462 28586 2772626073

301638112

PCB-1260 Peak 5 Ave 148 20034082 26592 25567 2477624302

270637128

PCB-1260 Peak 6 Ave 81 20038982 34673 33173 3331131697

343672090

PCB-1260 Peak 7 Ave 66 20023297 21847 20031 2012320512

211620048

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 183 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1260 Peak 8 Ave 59 20018824 17382 16914 1709216013

172450198

DCB Decachlorobiphenyl Ave 109 200544588 499440 455074 438703415700

470701073

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 184 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vr479200dLevel 2 IC 460-1299268 vr479201dLevel 3 IC 460-1299269 vr479202dLevel 4 IC 460-12992610 vr479203dLevel 5 IC 460-12992611 vr479204d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1LVL 2 LVL 2LVL 3 LVL 3LVL 4 LVL 4LVL 5 LVL 5

PCB-1016 Peak 1 Ave 2139086 7913738 14690255 21317999 34065069 100 500 1000 1500 2500PCB-1016 Peak 2 Ave 3443416 14188692 25503333 37720095 56733462 100 500 1000 1500 2500PCB-1016 Peak 3 Ave 2014938 9251204 16986172 25705034 42475382 100 500 1000 1500 2500PCB-1016 Peak 4 Ave 7533379 30672168 55786970 82482485 125050351 100 500 1000 1500 2500PCB-1016 Peak 5 Ave 2677413 11866731 21962918 32955239 50069130 100 500 1000 1500 2500PCB-1016 Peak 6 Ave 3086462 12239557 22517485 31648230 48815297 100 500 1000 1500 2500PCB-1016 Peak 7 Ave 2584175 11505820 21540272 32309208 50326849 100 500 1000 1500 2500PCB-1016 Peak 8 Ave 1261883 4734436 8630325 15857466 23748661 100 500 1000 1500 2500PCB-1260 Peak 1 Ave 4153239 16554914 31025367 45229464 68912349 100 500 1000 1500 2500PCB-1260 Peak 2 Ave 7841143 30454619 57128111 83094008 126227611 100 500 1000 1500 2500PCB-1260 Peak 3 Ave 6845178 27541094 53235986 77818190 121529078 100 500 1000 1500 2500PCB-1260 Peak 4 Ave 3797116 15230911 28586487 41589423 65183263 100 500 1000 1500 2500PCB-1260 Peak 5 Ave 3408191 13295973 25567248 37163734 60754093 100 500 1000 1500 2500PCB-1260 Peak 6 Ave 3898216 17336408 33172625 49966572 79243490 100 500 1000 1500 2500PCB-1260 Peak 7 Ave 2329661 10923449 20031237 30184937 51279969 100 500 1000 1500 2500PCB-1260 Peak 8 Ave 1882356 8691093 16914378 25637846 40032694 100 500 1000 1500 2500DCB Decachlorobiphenyl Ave 13614701 24972013 45507407 65805444 83140007 250 500 100 150 200

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 185 of 323

Data File vr479200d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479200dLab Smp Id IC-SG1660L1_00013 Inj Date 30-SEP-2012 1704 Operator Inst ID PESTGC9iSmp Info ic-SG1660L1_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 7 Calibration Sample Level 1Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2085 2085 0000 2139086 100000 130 8000- 12000 10000(M)

2527 2527 0000 3443416 100000 130 13324- 19985 16098

2777 2777 0000 2014938 100000 110 9975- 14963 9420

3128 3130 -0002 7533379 100000 130 29367- 44051 35218

3329 3330 -0001 2677413 100000 120 11758- 17638 12517

3682 3685 -0003 3086462 100000 130 11464- 17196 14429

4042 4043 -0001 2584175 100000 120 11819- 17728 12081

4190 4191 -0001 1261883 100000 120 5577- 8366 5899

Average of Peak Amounts = 123

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 4153239 100000 130 8000- 12000 10000

10162012Page 186 of 323

Data File vr479200d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 7841143 100000 130 14654- 21981 18880

6964 6964 0000 6845178 100000 120 14108- 21162 16482

7165 7165 0000 3797116 100000 120 7567- 11351 9143

7602 7602 0000 3408191 100000 120 7053- 10579 8206

8893 8893 0000 3898216 100000 110 9199- 13799 9386

9115 9115 0000 2329661 100000 110 5953- 8930 5609

10153 10153 0000 1882356 100000 110 4647- 6971 4532

Average of Peak Amounts = 121

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10625 10624 0001 13614701 250000 29 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 187 of 323

Data File vr479200d

Date 30-SEP-2012 1704

Client ID Instrument PESTGC9i

Sample Info ic-SG1660L1_00013 Operator

10162012Page 188 of 323

Data File vr479201d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479201dLab Smp Id IC-SG1660L2_00013 Inj Date 30-SEP-2012 1720 Operator Inst ID PESTGC9iSmp Info SG1660L2_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 8 Calibration Sample Level 2Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2084 2085 -0001 7913738 500000 500 8000- 12000 10000(M)

2526 2527 -0001 14188692 500000 520 13324- 19985 17929

2776 2777 -0001 9251204 500000 520 9975- 14963 11690

3128 3130 -0002 30672168 500000 520 29367- 44051 38758

3329 3330 -0001 11866731 500000 520 11758- 17638 14995

3682 3685 -0003 12239557 500000 520 11464- 17196 15466

4043 4043 0000 11505820 500000 510 11819- 17728 14539

4190 4191 -0001 4734436 500000 470 5577- 8366 5983

Average of Peak Amounts = 508

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 16554914 500000 510 8000- 12000 10000

10162012Page 189 of 323

Data File vr479201d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6523 6522 0001 30454619 500000 500 14654- 21981 18396

6965 6964 0001 27541094 500000 500 14108- 21162 16636

7165 7165 0000 15230911 500000 500 7567- 11351 9200

7603 7602 0001 13295973 500000 490 7053- 10579 8031

8894 8893 0001 17336408 500000 500 9199- 13799 10472

9115 9115 0000 10923449 500000 520 5953- 8930 6598

10154 10153 0001 8691093 500000 500 4647- 6971 5250

Average of Peak Amounts = 503

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10625 10624 0001 24972013 500000 53 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 190 of 323

Data File vr479201d

Date 30-SEP-2012 1720

Client ID Instrument PESTGC9i

Sample Info SG1660L2_00013 Operator

10162012Page 191 of 323

Data File vr479202d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479202dLab Smp Id IC-SG1660L3_00019 Inj Date 30-SEP-2012 1735 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 9 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2085 2085 0000 14690255 100000 920 8000- 12000 10000(M)

2527 2527 0000 25503333 100000 940 13324- 19985 17361

2777 2777 0000 16986172 100000 950 9975- 14963 11563

3130 3130 0000 55786970 100000 940 29367- 44051 37975

3330 3330 0000 21962918 100000 960 11758- 17638 14951

3685 3685 0000 22517485 100000 950 11464- 17196 15328

4043 4043 0000 21540272 100000 960 11819- 17728 14663

4191 4191 0000 8630325 100000 850 5577- 8366 5875

Average of Peak Amounts = 933

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 31025367 100000 950 8000- 12000 10000

10162012Page 192 of 323

Data File vr479202d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 57128111 100000 940 14654- 21981 18413

6964 6964 0000 53235986 100000 960 14108- 21162 17159

7165 7165 0000 28586487 100000 950 7567- 11351 9214

7602 7602 0000 25567248 100000 940 7053- 10579 8241

8893 8893 0000 33172625 100000 960 9199- 13799 10692

9115 9115 0000 20031237 100000 950 5953- 8930 6456

10153 10153 0000 16914378 100000 980 4647- 6971 5452

Average of Peak Amounts = 955

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 45507407 100000 97 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 193 of 323

Data File vr479202d

Date 30-SEP-2012 1735

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 194 of 323

Data File vr479203d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479203dLab Smp Id IC-SG1660L4_00013 Inj Date 30-SEP-2012 1751 Operator Inst ID PESTGC9iSmp Info SG1660L4_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 10 Calibration Sample Level 4Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2083 2085 -0002 21317999 150000 1300 8000- 12000 10000(M)

2527 2527 0000 37720095 150000 1400 13324- 19985 17694

2775 2777 -0002 25705034 150000 1400 9975- 14963 12058

3128 3130 -0002 82482485 150000 1400 29367- 44051 38691

3328 3330 -0002 32955239 150000 1400 11758- 17638 15459

3683 3685 -0002 31648230 150000 1300 11464- 17196 14846

4042 4043 -0001 32309208 150000 1400 11819- 17728 15156

4188 4191 -0003 15857466 150000 1600 5577- 8366 7439

Average of Peak Amounts = 141e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6071 6072 -0001 45229464 150000 1400 8000- 12000 10000

10162012Page 195 of 323

Data File vr479203d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 83094008 150000 1400 14654- 21981 18372

6963 6964 -0001 77818190 150000 1400 14108- 21162 17205

7164 7165 -0001 41589423 150000 1400 7567- 11351 9195

7602 7602 0000 37163734 150000 1400 7053- 10579 8217

8893 8893 0000 49966572 150000 1400 9199- 13799 11047

9115 9115 0000 30184937 150000 1400 5953- 8930 6674

10153 10153 0000 25637846 150000 1500 4647- 6971 5668

Average of Peak Amounts = 141e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 65805444 150000 140 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 196 of 323

Data File vr479203d

Date 30-SEP-2012 1751

Client ID Instrument PESTGC9i

Sample Info SG1660L4_00013 Operator

10162012Page 197 of 323

Data File vr479204d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479204dLab Smp Id IC-SG1660L5_00013 Inj Date 30-SEP-2012 1807 Operator Inst ID PESTGC9iSmp Info SG1660L5_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 11 Calibration Sample Level 5Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2084 2085 -0001 34065069 250000 2100 8000- 12000 10000(M)

2526 2527 -0001 56733462 250000 2100 13324- 19985 16654

2775 2777 -0002 42475382 250000 2400 9975- 14963 12469

3127 3130 -0003 125050351 250000 2100 29367- 44051 36709

3328 3330 -0002 50069130 250000 2200 11758- 17638 14698

3681 3685 -0004 48815297 250000 2000 11464- 17196 14330

4043 4043 0000 50326849 250000 2200 11819- 17728 14774

4190 4191 -0001 23748661 250000 2300 5577- 8366 6972

Average of Peak Amounts = 219e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6071 6072 -0001 68912349 250000 2100 8000- 12000 10000

10162012Page 198 of 323

Data File vr479204d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6521 6522 -0001 126227611 250000 2100 14654- 21981 18317

6964 6964 0000 121529078 250000 2200 14108- 21162 17635

7164 7165 -0001 65183263 250000 2200 7567- 11351 9459

7601 7602 -0001 60754093 250000 2200 7053- 10579 8816

8892 8893 -0001 79243490 250000 2300 9199- 13799 11499

9114 9115 -0001 51279969 250000 2400 5953- 8930 7441

10153 10153 0000 40032694 250000 2300 4647- 6971 5809

Average of Peak Amounts = 223e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 83140007 200000 180 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 199 of 323

Data File vr479204d

Date 30-SEP-2012 1807

Client ID Instrument PESTGC9i

Sample Info SG1660L5_00013 Operator

10162012Page 200 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vf479205d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1221 Peak 1 16651595 - 17351665PCB-1221 Peak 2 21352065 - 22052135PCB-1221 Peak 3 26722602 - 27422672PCB-1221 Peak 4 28732803 - 29432873PCB-1221 Peak 5 29612891 - 30312961PCB-1221 Peak 6 37393669 - 38093739PCB-1221 Peak 7 40834013 - 41534083PCB-1221 Peak 8 44774407 - 45474477

FORM VI 8082 10162012Page 201 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992612 vf479205d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

47106PCB-1221 Peak 1 Ave 20047106130012961PCB-1221 Peak 2 Ave 20012960750058524PCB-1221 Peak 3 Ave 20058523710040015PCB-1221 Peak 4 Ave 20040015420013789PCB-1221 Peak 5 Ave 20013788908018488PCB-1221 Peak 6 Ave 20018488040061501PCB-1221 Peak 7 Ave 20061500800024165PCB-1221 Peak 8 Ave 200241652800

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 202 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vf479205d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1221 Peak 1 Ave 4710613 1000PCB-1221 Peak 2 Ave 1296075 1000PCB-1221 Peak 3 Ave 5852371 1000PCB-1221 Peak 4 Ave 4001542 1000PCB-1221 Peak 5 Ave 13788908 1000PCB-1221 Peak 6 Ave 1848804 1000PCB-1221 Peak 7 Ave 615008 1000PCB-1221 Peak 8 Ave 2416528 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 203 of 323

Data File vf479205d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479205dLab Smp Id IC-SG1221L3_00014 Inj Date 30-SEP-2012 1822 Operator Inst ID PESTGC9iSmp Info ic SG1221L3_00014Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 12 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12210subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

22 Aroclor-1221 CAS 11104-28-2

1665 1665 0000 4710613 100000 1000 8000- 12000 10000

2135 2135 0000 1296075 100000 1000 2201- 3302 2751

2672 2672 0000 5852371 100000 1000 9939- 14909 12424

2873 2873 0000 4001542 100000 1000 6796- 10194 8495

2961 2961 0000 13788908 100000 1000 23418- 35126 29272

3739 3739 0000 1848804 100000 1000 3140- 4710 3925

4083 4083 0000 615008 100000 1000 1044- 1567 1306

4477 4477 0000 2416528 100000 1000 4104- 6156 5130

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 204 of 323

Data File vf479205d

Date 30-SEP-2012 1822

Client ID Instrument PESTGC9i

Sample Info ic SG1221L3_00014 Operator

10162012Page 205 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vr479205d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1221 Peak 1 11111041 - 11811111PCB-1221 Peak 2 15111441 - 15811511PCB-1221 Peak 3 18601790 - 19301860PCB-1221 Peak 4 20822012 - 21522082PCB-1221 Peak 5 25282458 - 25982528PCB-1221 Peak 6 26022532 - 26722602PCB-1221 Peak 7 26852615 - 27552685PCB-1221 Peak 8 31303060 - 32003130

FORM VI 8082 10162012Page 206 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992612 vr479205d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

64024PCB-1221 Peak 1 Ave 20064024020030571PCB-1221 Peak 2 Ave 20030571000095270PCB-1221 Peak 3 Ave 20095269770024981PCB-1221 Peak 4 Ave 20024981158027336PCB-1221 Peak 5 Ave 20027336400022123PCB-1221 Peak 6 Ave 20022122590041633PCB-1221 Peak 7 Ave 20041632790048909PCB-1221 Peak 8 Ave 200489094700

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 207 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vr479205d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1221 Peak 1 Ave 6402402 1000PCB-1221 Peak 2 Ave 3057100 1000PCB-1221 Peak 3 Ave 9526977 1000PCB-1221 Peak 4 Ave 24981158 1000PCB-1221 Peak 5 Ave 2733640 1000PCB-1221 Peak 6 Ave 2212259 1000PCB-1221 Peak 7 Ave 4163279 1000PCB-1221 Peak 8 Ave 4890947 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 208 of 323

Data File vr479205d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479205dLab Smp Id IC-SG1221L3_00014 Inj Date 30-SEP-2012 1822 Operator Inst ID PESTGC9iSmp Info ic SG1221L3_00014Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 12 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12210subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

22 Aroclor-1221 CAS 11104-28-2

1111 1111 0000 6402402 100000 1000 8000- 12000 10000(M)

1511 1511 0000 3057100 100000 1000 3820- 5730 4775

1860 1860 0000 9526977 100000 1000 11904- 17856 14880

2082 2082 0000 24981158 100000 1000 31215- 46822 39018

2528 2528 0000 2733640 100000 1000 3416- 5124 4270

2602 2602 0000 2212259 100000 1000 2764- 4146 3455

2685 2685 0000 4163279 100000 1000 5202- 7803 6503

3130 3130 0000 4890947 100000 1000 6111- 9167 7639

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 209 of 323

Data File vr479205d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 210 of 323

Data File vr479205d

Date 30-SEP-2012 1822

Client ID Instrument PESTGC9i

Sample Info ic SG1221L3_00014 Operator

10162012Page 211 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vf479206d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1232 Peak 1 29612891 - 30312961PCB-1232 Peak 2 36403570 - 37103640PCB-1232 Peak 3 40854015 - 41554085PCB-1232 Peak 4 47224652 - 47924722PCB-1232 Peak 5 49024832 - 49724902PCB-1232 Peak 6 50875017 - 51575087PCB-1232 Peak 7 55425472 - 56125542PCB-1232 Peak 8 57515681 - 58215751

FORM VI 8082 10162012Page 212 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992613 vf479206d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

97711PCB-1232 Peak 1 Ave 20097710620094688PCB-1232 Peak 2 Ave 20094688030035761PCB-1232 Peak 3 Ave 20035761260066995PCB-1232 Peak 4 Ave 20066994820050607PCB-1232 Peak 5 Ave 20050607280041053PCB-1232 Peak 6 Ave 20041053380057396PCB-1232 Peak 7 Ave 20057395890062677PCB-1232 Peak 8 Ave 200626765000

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 213 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vf479206d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1232 Peak 1 Ave 9771062 1000PCB-1232 Peak 2 Ave 9468803 1000PCB-1232 Peak 3 Ave 3576126 1000PCB-1232 Peak 4 Ave 6699482 1000PCB-1232 Peak 5 Ave 5060728 1000PCB-1232 Peak 6 Ave 4105338 1000PCB-1232 Peak 7 Ave 5739589 1000PCB-1232 Peak 8 Ave 6267650 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 214 of 323

Data File vf479206d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479206dLab Smp Id ic SG1232L3_00013 Inj Date 30-SEP-2012 1838 Operator Inst ID PESTGC9iSmp Info ic SG1232L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 13 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12320subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

23 Aroclor-1232 CAS 11141-16-5

2961 2961 0000 9771062 100000 1000 8000- 12000 10000

3640 3640 0000 9468803 100000 1000 7753- 11629 9691

4085 4085 0000 3576126 100000 1000 2928- 4392 3660

4722 4722 0000 6699482 100000 1000 5485- 8228 6856

4902 4902 0000 5060728 100000 1000 4143- 6215 5179

5087 5087 0000 4105338 100000 1000 3361- 5042 4202

5542 5542 0000 5739589 100000 1000 4699- 7049 5874

5751 5751 0000 6267650 100000 1000 5132- 7697 6415

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 215 of 323

Data File vf479206d

Date 30-SEP-2012 1838

Client ID Instrument PESTGC9i

Sample Info ic SG1232L3_00013 Operator

10162012Page 216 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vr479206d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1232 Peak 1 20822012 - 21522082PCB-1232 Peak 2 25262456 - 25962526PCB-1232 Peak 3 27762706 - 28462776PCB-1232 Peak 4 31283058 - 31983128PCB-1232 Peak 5 33293259 - 33993329PCB-1232 Peak 6 34243354 - 34943424PCB-1232 Peak 7 40423972 - 41124042PCB-1232 Peak 8 46144544 - 46844614

FORM VI 8082 10162012Page 217 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992613 vr479206d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

18402PCB-1232 Peak 1 Ave 20018402354014182PCB-1232 Peak 2 Ave 20014181613010089PCB-1232 Peak 3 Ave 20010089309027669PCB-1232 Peak 4 Ave 20027669356010841PCB-1232 Peak 5 Ave 20010840936085833PCB-1232 Peak 6 Ave 20085833230011581PCB-1232 Peak 7 Ave 20011580551048393PCB-1232 Peak 8 Ave 200483934800

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 218 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vr479206d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1232 Peak 1 Ave 18402354 1000PCB-1232 Peak 2 Ave 14181613 1000PCB-1232 Peak 3 Ave 10089309 1000PCB-1232 Peak 4 Ave 27669356 1000PCB-1232 Peak 5 Ave 10840936 1000PCB-1232 Peak 6 Ave 8583323 1000PCB-1232 Peak 7 Ave 11580551 1000PCB-1232 Peak 8 Ave 4839348 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 219 of 323

Data File vr479206d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479206dLab Smp Id ic SG1232L3_00013 Inj Date 30-SEP-2012 1838 Operator Inst ID PESTGC9iSmp Info ic SG1232L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 13 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12320subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

23 Aroclor-1232 CAS 11141-16-5

2082 2082 0000 18402354 100000 1000 8000- 12000 10000

2526 2526 0000 14181613 100000 1000 6165- 9248 7706

2776 2776 0000 10089309 100000 1000 4386- 6579 5483

3128 3128 0000 27669356 100000 1000 12029- 18043 15036

3329 3329 0000 10840936 100000 1000 4713- 7069 5891

3424 3424 0000 8583323 100000 1000 3731- 5597 4664

4042 4042 0000 11580551 100000 1000 5034- 7552 6293

4614 4614 0000 4839348 100000 1000 2104- 3156 2630

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 220 of 323

Data File vr479206d

Date 30-SEP-2012 1838

Client ID Instrument PESTGC9i

Sample Info ic SG1232L3_00013 Operator

10162012Page 221 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vf479207d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1242 Peak 1 29612891 - 30312961PCB-1242 Peak 2 36413571 - 37113641PCB-1242 Peak 3 40864016 - 41564086PCB-1242 Peak 4 44794409 - 45494479PCB-1242 Peak 5 47234653 - 47934723PCB-1242 Peak 6 51585088 - 52285158PCB-1242 Peak 7 57525682 - 58225752PCB-1242 Peak 8 62656195 - 63356265

FORM VI 8082 10162012Page 222 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992614 vf479207d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

81414PCB-1242 Peak 1 Ave 20081414290015365PCB-1242 Peak 2 Ave 20015365311065982PCB-1242 Peak 3 Ave 20065981950028106PCB-1242 Peak 4 Ave 20028106459012209PCB-1242 Peak 5 Ave 20012208628069961PCB-1242 Peak 6 Ave 20069960990010615PCB-1242 Peak 7 Ave 20010615499010283PCB-1242 Peak 8 Ave 200102828980

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 223 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vf479207d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1242 Peak 1 Ave 8141429 1000PCB-1242 Peak 2 Ave 15365311 1000PCB-1242 Peak 3 Ave 6598195 1000PCB-1242 Peak 4 Ave 28106459 1000PCB-1242 Peak 5 Ave 12208628 1000PCB-1242 Peak 6 Ave 6996099 1000PCB-1242 Peak 7 Ave 10615499 1000PCB-1242 Peak 8 Ave 10282898 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 224 of 323

Data File vf479207d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479207dLab Smp Id ic SG1242L3_00013 Inj Date 30-SEP-2012 1854 Operator Inst ID PESTGC9iSmp Info ic SG1242L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 14 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12420subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

24 Aroclor-1242 CAS 53469-21-9

2961 2961 0000 8141429 100000 1000 8000- 12000 10000(M)

3641 3641 0000 15365311 100000 1000 15098- 22648 18873

4086 4086 0000 6598195 100000 1000 6484- 9725 8104

4479 4479 0000 28106459 100000 1000 27618- 41427 34523

4723 4723 0000 12208628 100000 1000 11997- 17995 14996

5158 5158 0000 6996099 100000 1000 6875- 10312 8593

5752 5752 0000 10615499 100000 1000 10431- 15647 13039

6265 6265 0000 10282898 100000 1000 10104- 15156 12630

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 225 of 323

Data File vf479207d Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 226 of 323

Data File vf479207d

Date 30-SEP-2012 1854

Client ID Instrument PESTGC9i

Sample Info ic SG1242L3_00013 Operator

10162012Page 227 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vr479207d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1242 Peak 1 20832013 - 21532083PCB-1242 Peak 2 25272457 - 25972527PCB-1242 Peak 3 27772707 - 28472777PCB-1242 Peak 4 31293059 - 31993129PCB-1242 Peak 5 33293259 - 33993329PCB-1242 Peak 6 36853615 - 37553685PCB-1242 Peak 7 40443974 - 41144044PCB-1242 Peak 8 51265056 - 51965126

FORM VI 8082 10162012Page 228 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992614 vr479207d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

13527PCB-1242 Peak 1 Ave 20013526845020219PCB-1242 Peak 2 Ave 20020218998014340PCB-1242 Peak 3 Ave 20014339987044262PCB-1242 Peak 4 Ave 20044261735017388PCB-1242 Peak 5 Ave 20017387684018314PCB-1242 Peak 6 Ave 20018314121017750PCB-1242 Peak 7 Ave 20017749733015393PCB-1242 Peak 8 Ave 200153932670

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 229 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vr479207d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1242 Peak 1 Ave 13526845 1000PCB-1242 Peak 2 Ave 20218998 1000PCB-1242 Peak 3 Ave 14339987 1000PCB-1242 Peak 4 Ave 44261735 1000PCB-1242 Peak 5 Ave 17387684 1000PCB-1242 Peak 6 Ave 18314121 1000PCB-1242 Peak 7 Ave 17749733 1000PCB-1242 Peak 8 Ave 15393267 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 230 of 323

Data File vr479207d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479207dLab Smp Id ic SG1242L3_00013 Inj Date 30-SEP-2012 1854 Operator Inst ID PESTGC9iSmp Info ic SG1242L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 14 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12420subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

24 Aroclor-1242 CAS 53469-21-9

2083 2083 0000 13526845 100000 1000 8000- 12000 10000(M)

2527 2527 0000 20218998 100000 1000 11958- 17937 14947

2777 2777 0000 14339987 100000 1000 8481- 12721 10601

3129 3129 0000 44261735 100000 1000 26177- 39266 32721

3329 3329 0000 17387684 100000 1000 10283- 15425 12854

3685 3685 0000 18314121 100000 1000 10831- 16247 13539

4044 4044 0000 17749733 100000 1000 10497- 15746 13122

5126 5126 0000 15393267 100000 1000 9104- 13656 11380

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 231 of 323

Data File vr479207d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 232 of 323

Data File vr479207d

Date 30-SEP-2012 1854

Client ID Instrument PESTGC9i

Sample Info ic SG1242L3_00013 Operator

10162012Page 233 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vf479208d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1248 Peak 1 36373567 - 37073637PCB-1248 Peak 2 44734403 - 45434473PCB-1248 Peak 3 49514881 - 50214951PCB-1248 Peak 4 50865016 - 51565086PCB-1248 Peak 5 55415471 - 56115541PCB-1248 Peak 6 57505680 - 58205750PCB-1248 Peak 7 61916121 - 62616191PCB-1248 Peak 8 62626192 - 63326262

FORM VI 8082 10162012Page 234 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992615 vf479208d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

89356PCB-1248 Peak 1 Ave 20089355610020760PCB-1248 Peak 2 Ave 20020759623031559PCB-1248 Peak 3 Ave 20031559070012341PCB-1248 Peak 4 Ave 20012341389015809PCB-1248 Peak 5 Ave 20015808884017466PCB-1248 Peak 6 Ave 20017465791016624PCB-1248 Peak 7 Ave 20016623508019431PCB-1248 Peak 8 Ave 200194311040

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 235 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vf479208d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1248 Peak 1 Ave 8935561 1000PCB-1248 Peak 2 Ave 20759623 1000PCB-1248 Peak 3 Ave 3155907 1000PCB-1248 Peak 4 Ave 12341389 1000PCB-1248 Peak 5 Ave 15808884 1000PCB-1248 Peak 6 Ave 17465791 1000PCB-1248 Peak 7 Ave 16623508 1000PCB-1248 Peak 8 Ave 19431104 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 236 of 323

Data File vf479208d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479208dLab Smp Id ic SG1248L3_00013 Inj Date 30-SEP-2012 1909 Operator Inst ID PESTGC9iSmp Info ic SG1248L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 15 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12480subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

25 Aroclor-1248 CAS 12672-29-6

3637 3637 0000 8935561 100000 1000 8000- 12000 10000

4473 4473 0000 20759623 100000 1000 18586- 27879 23233

4951 4951 0000 3155907 100000 1000 2825- 4238 3532

5086 5086 0000 12341389 100000 1000 11049- 16574 13812

5541 5541 0000 15808884 100000 1000 14154- 21231 17692

5750 5750 0000 17465791 100000 1000 15637- 23456 19546

6191 6191 0000 16623508 100000 1000 14883- 22325 18604

6262 6262 0000 19431104 100000 1000 17397- 26095 21746

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 237 of 323

Data File vf479208d

Date 30-SEP-2012 1909

Client ID Instrument PESTGC9i

Sample Info ic SG1248L3_00013 Operator

10162012Page 238 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vr479208d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1248 Peak 1 25252455 - 25952525PCB-1248 Peak 2 31243054 - 31943124PCB-1248 Peak 3 34233353 - 34933423PCB-1248 Peak 4 36783608 - 37483678PCB-1248 Peak 5 40413971 - 41114041PCB-1248 Peak 6 41864116 - 42564186PCB-1248 Peak 7 46154545 - 46854615PCB-1248 Peak 8 51245054 - 51945124

FORM VI 8082 10162012Page 239 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992615 vr479208d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

11417PCB-1248 Peak 1 Ave 20011416682034274PCB-1248 Peak 2 Ave 20034273988063635PCB-1248 Peak 3 Ave 20063635020034030PCB-1248 Peak 4 Ave 20034030097030220PCB-1248 Peak 5 Ave 20030220358018203PCB-1248 Peak 6 Ave 20018202681015611PCB-1248 Peak 7 Ave 20015610993034370PCB-1248 Peak 8 Ave 200343696460

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 240 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vr479208d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1248 Peak 1 Ave 11416682 1000PCB-1248 Peak 2 Ave 34273988 1000PCB-1248 Peak 3 Ave 6363502 1000PCB-1248 Peak 4 Ave 34030097 1000PCB-1248 Peak 5 Ave 30220358 1000PCB-1248 Peak 6 Ave 18202681 1000PCB-1248 Peak 7 Ave 15610993 1000PCB-1248 Peak 8 Ave 34369646 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 241 of 323

Data File vr479208d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479208dLab Smp Id ic SG1248L3_00013 Inj Date 30-SEP-2012 1909 Operator Inst ID PESTGC9iSmp Info ic SG1248L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 15 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12480subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

25 Aroclor-1248 CAS 12672-29-6

2525 2525 0000 11416682 100000 1000 8000- 12000 10000(M)

3124 3124 0000 34273988 100000 1000 24017- 36025 30021

3423 3423 0000 6363502 100000 1000 4459- 6689 5574

3678 3678 0000 34030097 100000 1000 23846- 35769 29807

4041 4041 0000 30220358 100000 1000 21176- 31764 26470

4186 4186 0000 18202681 100000 1000 12755- 19133 15944

4615 4615 0000 15610993 100000 1000 10939- 16409 13674

5124 5124 0000 34369646 100000 1000 24084- 36126 30105

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 242 of 323

Data File vr479208d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 243 of 323

Data File vr479208d

Date 30-SEP-2012 1909

Client ID Instrument PESTGC9i

Sample Info ic SG1248L3_00013 Operator

10162012Page 244 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vf479209d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1254 Peak 1 50855015 - 51555085PCB-1254 Peak 2 62536183 - 63236253PCB-1254 Peak 3 65806510 - 66506580PCB-1254 Peak 4 71577087 - 72277157PCB-1254 Peak 5 73717301 - 74417371PCB-1254 Peak 6 85968526 - 86668596PCB-1254 Peak 7 90869016 - 91569086PCB-1254 Peak 8 98439773 - 99139843

FORM VI 8082 10162012Page 245 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992616 vf479209d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

97124PCB-1254 Peak 1 Ave 20097124230016374PCB-1254 Peak 2 Ave 20016373834017590PCB-1254 Peak 3 Ave 20017589776013684PCB-1254 Peak 4 Ave 20013683949027505PCB-1254 Peak 5 Ave 20027504947017262PCB-1254 Peak 6 Ave 20017261880028714PCB-1254 Peak 7 Ave 20028713900074774PCB-1254 Peak 8 Ave 200747739500

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 246 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vf479209d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1254 Peak 1 Ave 9712423 1000PCB-1254 Peak 2 Ave 16373834 1000PCB-1254 Peak 3 Ave 17589776 1000PCB-1254 Peak 4 Ave 13683949 1000PCB-1254 Peak 5 Ave 27504947 1000PCB-1254 Peak 6 Ave 17261880 1000PCB-1254 Peak 7 Ave 28713900 1000PCB-1254 Peak 8 Ave 7477395 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 247 of 323

Data File vf479209d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479209dLab Smp Id ic SG1254L3_00013 Inj Date 30-SEP-2012 1925 Operator Inst ID PESTGC9iSmp Info ic SG1254L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 16 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12540subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

26 Aroclor-1254 CAS 11097-69-1

5085 5085 0000 9712423 100000 1000 8000- 12000 10000

6253 6253 0000 16373834 100000 1000 13487- 20230 16859

6580 6580 0000 17589776 100000 1000 14488- 21733 18111

7157 7157 0000 13683949 100000 1000 11271- 16907 14089

7371 7371 0000 27504947 100000 1000 22655- 33983 28319

8596 8596 0000 17261880 100000 1000 14218- 21328 17773

9086 9086 0000 28713900 100000 1000 23651- 35477 29564

9843 9843 0000 7477395 100000 1000 6159- 9239 7699

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 248 of 323

Data File vf479209d

Date 30-SEP-2012 1925

Client ID Instrument PESTGC9i

Sample Info ic SG1254L3_00013 Operator

10162012Page 249 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vr479209d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1254 Peak 1 46874617 - 47574687PCB-1254 Peak 2 47624692 - 48324762PCB-1254 Peak 3 51285058 - 51985128PCB-1254 Peak 4 55695499 - 56395569PCB-1254 Peak 5 57705700 - 58405770PCB-1254 Peak 6 62216151 - 62916221PCB-1254 Peak 7 65216451 - 65916521PCB-1254 Peak 8 69656895 - 70356965

FORM VI 8082 10162012Page 250 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992616 vr479209d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

24886PCB-1254 Peak 1 Ave 20024885981024126PCB-1254 Peak 2 Ave 20024125717033197PCB-1254 Peak 3 Ave 20033196979024470PCB-1254 Peak 4 Ave 20024470162043009PCB-1254 Peak 5 Ave 20043008616038112PCB-1254 Peak 6 Ave 20038111884031186PCB-1254 Peak 7 Ave 20031186488041987PCB-1254 Peak 8 Ave 200419870070

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 251 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vr479209d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1254 Peak 1 Ave 24885981 1000PCB-1254 Peak 2 Ave 24125717 1000PCB-1254 Peak 3 Ave 33196979 1000PCB-1254 Peak 4 Ave 24470162 1000PCB-1254 Peak 5 Ave 43008616 1000PCB-1254 Peak 6 Ave 38111884 1000PCB-1254 Peak 7 Ave 31186488 1000PCB-1254 Peak 8 Ave 41987007 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 252 of 323

Data File vr479209d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479209dLab Smp Id ic SG1254L3_00013 Inj Date 30-SEP-2012 1925 Operator Inst ID PESTGC9iSmp Info ic SG1254L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 16 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12540subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

26 Aroclor-1254 CAS 11097-69-1

4687 4687 0000 24885981 100000 1000 8000- 12000 10000(M)

4762 4762 0000 24125717 100000 1000 7756- 11633 9695

5128 5128 0000 33196979 100000 1000 10672- 16008 13340

5569 5569 0000 24470162 100000 1000 7866- 11799 9833

5770 5770 0000 43008616 100000 1000 13826- 20739 17282

6221 6221 0000 38111884 100000 1000 12252- 18378 15315

6521 6521 0000 31186488 100000 1000 10025- 15038 12532

6965 6965 0000 41987007 100000 1000 13497- 20246 16872

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 253 of 323

Data File vr479209d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 254 of 323

Data File vr479209d

Date 30-SEP-2012 1925

Client ID Instrument PESTGC9i

Sample Info ic SG1254L3_00013 Operator

10162012Page 255 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-2

TestAmerica Edison

Lab File ID vf479493d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1005610273 979 1000 -21 150Ave

PCB-1016 Peak 2 2214321113 1050 1000 49 150Ave

PCB-1016 Peak 3 96058714 1100 1000 102 150Ave

PCB-1016 Peak 4 4004137710 1060 1000 62 150Ave

PCB-1016 Peak 5 1906116455 1160 1000 158 150Ave

PCB-1016 Peak 6 104069770 1070 1000 65 150Ave

PCB-1016 Peak 7 1271211990 1060 1000 60 150Ave

PCB-1016 Peak 8 1381712146 1140 1000 138 150Ave

PCB-1260 Peak 1 2403322106 1090 1000 87 150Ave

PCB-1260 Peak 2 2694125092 1070 1000 74 150Ave

PCB-1260 Peak 3 4112136867 1120 1000 115 150Ave

PCB-1260 Peak 4 1829116241 1130 1000 126 150Ave

PCB-1260 Peak 5 102408814 1160 1000 162 150Ave

PCB-1260 Peak 6 1863416926 1100 1000 101 150Ave

PCB-1260 Peak 7 2108721064 1000 1000 01 150Ave

PCB-1260 Peak 8 80147857 1020 1000 20 150Ave

DCB Decachlorobiphenyl 267686265963 101 100 06 150Ave

FORM VII 8082

10162012Page 256 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-2

TestAmerica Edison

Lab File ID vf479493d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 292 289 303

PCB-1016 Peak 2 359 357 371

PCB-1016 Peak 3 404 401 415

PCB-1016 Peak 4 443 441 455

PCB-1016 Peak 5 468 465 479

PCB-1016 Peak 6 511 509 523

PCB-1016 Peak 7 550 547 561

PCB-1016 Peak 8 571 568 582

PCB-1260 Peak 1 771 769 783

PCB-1260 Peak 2 816 814 828

PCB-1260 Peak 3 902 901 915

PCB-1260 Peak 4 928 926 940

PCB-1260 Peak 5 940 938 952

PCB-1260 Peak 6 986 983 997

PCB-1260 Peak 7 1059 1055 1069

PCB-1260 Peak 8 1106 1102 1116

DCB Decachlorobiphenyl 1149 1141 1161

Form VII 8082

10162012Page 257 of 323

Data File vf479493d Report Date 09-Oct-2012 0318

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479493dLab Smp Id ccvrtsg1660l3_00019 Inj Date 08-OCT-2012 1830 Operator Inst ID PESTGC9iSmp Info ccvrt-sg1660l3_00019Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 21 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2923 2961 -0038 10055641 978875 650 8000- 12000 10000(M)

3593 3641 -0048 22143043 104879 700 16892- 25338 22021

4036 4085 -0049 9604932 110224 730 6889- 10334 9552

4432 4479 -0047 40041013 106181 710 30481- 45721 39819

4678 4722 -0044 19061275 115840 770 13320- 19980 18956

5114 5158 -0044 10405886 106506 710 7564- 11346 10348

5500 5542 -0042 12711848 106020 710 9332- 13998 12642

5709 5752 -0043 13817418 113758 760 9784- 14675 13741

Average of Peak Concentrations = 720

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7706 7756 -0050 24033075 108715 720 8000- 12000 10000(M)

10162012Page 258 of 323

Data File vf479493d Report Date 09-Oct-2012 0318

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8161 8215 -0054 26941342 107369 720 9103- 13655 11210

9020 9084 -0064 41121424 111541 740 14090- 21136 17110

9276 9332 -0056 18291174 112626 750 6105- 9158 7611

9401 9454 -0053 10239798 116171 770 3460- 5190 4261

9861 9901 -0040 18634445 110097 730 6444- 9666 7754

10594 10616 -0022 21087197 100112 670 7926- 11889 12194

11063 11086 -0023 8014273 101999 680 2968- 4452 3335

Average of Peak Concentrations = 720

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11488 11515 -0027 26768608 100648 67 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 259 of 323

Data File vf479493d

Date 08-OCT-2012 1830

Client ID Instrument PESTGC9i

Sample Info ccvrt-sg1660l3_00019 Operator

10162012Page 260 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-1

TestAmerica Edison

Lab File ID vr479493d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1317915949 826 1000 -174 150Ave

PCB-1016 Peak 2 2492127231 915 1000 -85 150Ave

PCB-1016 Peak 3 1751817953 976 1000 -24 150Ave

PCB-1016 Peak 4 5583559495 938 1000 -62 150Ave

PCB-1016 Peak 5 2224122894 971 1000 -29 150Ave

PCB-1016 Peak 6 2383923697 1010 1000 06 150Ave

PCB-1016 Peak 7 2233922413 997 1000 -03 150Ave

PCB-1016 Peak 8 1103010158 1090 1000 86 150Ave

PCB-1260 Peak 1 3241432677 992 1000 -08 150Ave

PCB-1260 Peak 2 6068660467 1000 1000 04 150Ave

PCB-1260 Peak 3 5752255452 1040 1000 37 150Ave

PCB-1260 Peak 4 2973730164 986 1000 -14 150Ave

PCB-1260 Peak 5 2720927064 1010 1000 05 150Ave

PCB-1260 Peak 6 3391634367 987 1000 -13 150Ave

PCB-1260 Peak 7 2498721162 1180 1000 181 150Ave

PCB-1260 Peak 8 1900217245 1100 1000 102 150Ave

DCB Decachlorobiphenyl 482177470701 102 100 24 150Ave

FORM VII 8082

10162012Page 261 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-1

TestAmerica Edison

Lab File ID vr479493d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 206 201 215

PCB-1016 Peak 2 250 246 260

PCB-1016 Peak 3 275 271 285

PCB-1016 Peak 4 310 306 320

PCB-1016 Peak 5 330 326 340

PCB-1016 Peak 6 365 361 375

PCB-1016 Peak 7 401 397 411

PCB-1016 Peak 8 416 412 426

PCB-1260 Peak 1 604 600 614

PCB-1260 Peak 2 650 645 659

PCB-1260 Peak 3 694 689 703

PCB-1260 Peak 4 714 709 723

PCB-1260 Peak 5 757 753 767

PCB-1260 Peak 6 886 882 896

PCB-1260 Peak 7 908 904 918

PCB-1260 Peak 8 1013 1008 1022

DCB Decachlorobiphenyl 1061 1052 1072

Form VII 8082

10162012Page 262 of 323

Data File vr479493d Page 1 Report Date 09-Oct-2012 0318

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479493dLab Smp Id ccvrtsg1660l3_00019 Inj Date 08-OCT-2012 1830 Operator Inst ID PESTGC9iSmp Info ccvrt-sg1660l3_00019Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 21 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2056 2085 -0029 13178629 826281 550 8000- 12000 10000(M)

2498 2527 -0029 24921299 915181 610 13324- 19985 18910

2746 2777 -0031 17517717 975756 650 9975- 14963 13293

3100 3130 -0030 55834574 938480 620 29367- 44051 42368

3297 3330 -0033 22240639 971476 650 11758- 17638 16876

3648 3685 -0037 23838665 100597 670 11464- 17196 18089

4011 4043 -0032 22339236 996719 660 11819- 17728 16951

4157 4191 -0034 11029779 108584 720 5577- 8366 8369

Average of Peak Concentrations = 640

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6045 6072 -0027 32414247 991956 660 8000- 12000 10000(M)

10162012Page 263 of 323

Data File vr479493d Page 2 Report Date 09-Oct-2012 0318

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6496 6522 -0026 60686283 100362 670 14654- 21981 18722

6938 6964 -0026 57521890 103733 690 14108- 21162 17746

7137 7165 -0028 29736966 985849 660 7567- 11351 9174

7572 7602 -0030 27208663 100536 670 7053- 10579 8394

8857 8893 -0036 33916486 986885 660 9199- 13799 10463

9076 9115 -0039 24987061 118075 790 5953- 8930 7709

10135 10153 -0018 19001807 110187 730 4647- 6971 5862

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 48217685 102438 68 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 264 of 323

Data File vr479493d

Date 08-OCT-2012 1830

Client ID Instrument PESTGC9i

Sample Info ccvrt-sg1660l3_00019 Operator

10162012Page 265 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-2

TestAmerica Edison

Lab File ID vf479510d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 998310273 972 1000 -28 150Ave

PCB-1016 Peak 2 2182221113 1030 1000 34 150Ave

PCB-1016 Peak 3 93438714 1070 1000 72 150Ave

PCB-1016 Peak 4 3888937710 1030 1000 31 150Ave

PCB-1016 Peak 5 1831616455 1110 1000 113 150Ave

PCB-1016 Peak 6 100909770 1030 1000 33 150Ave

PCB-1016 Peak 7 1211711990 1010 1000 11 150Ave

PCB-1016 Peak 8 1287812146 1060 1000 60 150Ave

PCB-1260 Peak 1 2305022106 1040 1000 43 150Ave

PCB-1260 Peak 2 2601125092 1040 1000 37 150Ave

PCB-1260 Peak 3 4009636867 1090 1000 88 150Ave

PCB-1260 Peak 4 1793216241 1100 1000 104 150Ave

PCB-1260 Peak 5 100168814 1140 1000 136 150Ave

PCB-1260 Peak 6 1799416926 1060 1000 63 150Ave

PCB-1260 Peak 7 2148621064 1020 1000 20 150Ave

PCB-1260 Peak 8 78557857 1000 1000 -00 150Ave

DCB Decachlorobiphenyl 262499265963 987 100 -13 150Ave

FORM VII 8082

10162012Page 266 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-2

TestAmerica Edison

Lab File ID vf479510d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 292 289 303

PCB-1016 Peak 2 359 357 371

PCB-1016 Peak 3 403 401 415

PCB-1016 Peak 4 443 441 455

PCB-1016 Peak 5 468 465 479

PCB-1016 Peak 6 511 509 523

PCB-1016 Peak 7 550 547 561

PCB-1016 Peak 8 571 568 582

PCB-1260 Peak 1 770 769 783

PCB-1260 Peak 2 816 814 828

PCB-1260 Peak 3 902 901 915

PCB-1260 Peak 4 927 926 940

PCB-1260 Peak 5 940 938 952

PCB-1260 Peak 6 986 983 997

PCB-1260 Peak 7 1059 1055 1069

PCB-1260 Peak 8 1106 1102 1116

DCB Decachlorobiphenyl 1149 1141 1161

Form VII 8082

10162012Page 267 of 323

Data File vf479510d Report Date 09-Oct-2012 0335

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479510dLab Smp Id ccv-SG1660L3_00019 Inj Date 09-OCT-2012 0147 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 40 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2922 2961 -0039 9983429 971845 650 8000- 12000 10000(M)

3591 3641 -0050 21822420 103360 690 16892- 25338 21859

4034 4085 -0051 9342806 107216 710 6889- 10334 9358

4431 4479 -0048 38888611 103125 690 30481- 45721 38953

4677 4722 -0045 18315559 111308 740 13320- 19980 18346

5112 5158 -0046 10089629 103269 690 7564- 11346 10106

5497 5542 -0045 12117410 101063 670 9332- 13998 12138

5706 5752 -0046 12878214 106025 710 9784- 14675 12900

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7703 7756 -0053 23050032 104269 700 8000- 12000 10000(M)

10162012Page 268 of 323

Data File vf479510d Report Date 09-Oct-2012 0335

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8159 8215 -0056 26011086 103662 690 9103- 13655 11285

9017 9084 -0067 40095841 108759 720 14090- 21136 17395

9273 9332 -0059 17931794 110413 740 6105- 9158 7780

9399 9454 -0055 10016237 113634 760 3460- 5190 4345

9858 9901 -0043 17994170 106314 710 6444- 9666 7807

10594 10616 -0022 21485546 102003 680 7926- 11889 12478

11061 11086 -0025 7855172 999743 670 2968- 4452 3408

Average of Peak Concentrations = 710

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11485 11515 -0030 26249946 986977 66 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 269 of 323

Data File vf479510d

Date 09-OCT-2012 0147

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 270 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-1

TestAmerica Edison

Lab File ID vr479510d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1577315949 989 1000 -11 150Ave

PCB-1016 Peak 2 2637627231 969 1000 -31 150Ave

PCB-1016 Peak 3 1911517953 1060 1000 65 150Ave

PCB-1016 Peak 4 5729159495 963 1000 -37 150Ave

PCB-1016 Peak 5 2290722894 1000 1000 00 150Ave

PCB-1016 Peak 6 2510823697 1060 1000 60 150Ave

PCB-1016 Peak 7 2349222413 1050 1000 48 150Ave

PCB-1016 Peak 8 1095310158 1080 1000 78 150Ave

PCB-1260 Peak 1 3177332677 972 1000 -28 150Ave

PCB-1260 Peak 2 5864160467 970 1000 -30 150Ave

PCB-1260 Peak 3 5561155452 1000 1000 03 150Ave

PCB-1260 Peak 4 2920530164 968 1000 -32 150Ave

PCB-1260 Peak 5 2692527064 995 1000 -05 150Ave

PCB-1260 Peak 6 3316834367 965 1000 -35 150Ave

PCB-1260 Peak 7 2309521162 1090 1000 91 150Ave

PCB-1260 Peak 8 1649517245 957 1000 -43 150Ave

DCB Decachlorobiphenyl 444399470701 944 100 -56 150Ave

FORM VII 8082

10162012Page 271 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-1

TestAmerica Edison

Lab File ID vr479510d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 206 201 215

PCB-1016 Peak 2 250 246 260

PCB-1016 Peak 3 275 271 285

PCB-1016 Peak 4 310 306 320

PCB-1016 Peak 5 330 326 340

PCB-1016 Peak 6 365 361 375

PCB-1016 Peak 7 401 397 411

PCB-1016 Peak 8 416 412 426

PCB-1260 Peak 1 604 600 614

PCB-1260 Peak 2 649 645 659

PCB-1260 Peak 3 694 689 703

PCB-1260 Peak 4 714 709 723

PCB-1260 Peak 5 757 753 767

PCB-1260 Peak 6 885 882 896

PCB-1260 Peak 7 907 904 918

PCB-1260 Peak 8 1013 1008 1022

DCB Decachlorobiphenyl 1061 1052 1072

Form VII 8082

10162012Page 272 of 323

Data File vr479510d Page 1 Report Date 09-Oct-2012 0335

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479510dLab Smp Id ccv-SG1660L3_00019 Inj Date 09-OCT-2012 0147 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 40 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2056 2085 -0029 15772630 988922 660 8000- 12000 10000(M)

2498 2527 -0029 26375750 968593 640 13324- 19985 16722

2747 2777 -0030 19114706 106471 710 9975- 14963 12119

3099 3130 -0031 57290957 962959 640 29367- 44051 36323

3296 3330 -0034 22907341 100060 670 11758- 17638 14523

3645 3685 -0040 25108132 105954 710 11464- 17196 15919

4009 4043 -0034 23491941 104815 700 11819- 17728 14894

4155 4191 -0036 10952986 107828 720 5577- 8366 6944

Average of Peak Concentrations = 680

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6043 6072 -0029 31772880 972329 650 8000- 12000 10000(M)

10162012Page 273 of 323

Data File vr479510d Page 2 Report Date 09-Oct-2012 0335

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6494 6522 -0028 58641225 969803 650 14654- 21981 18456

6936 6964 -0028 55611337 100287 670 14108- 21162 17503

7135 7165 -0030 29205460 968228 640 7567- 11351 9192

7570 7602 -0032 26925453 994891 660 7053- 10579 8474

8854 8893 -0039 33168029 965107 640 9199- 13799 10439

9072 9115 -0043 23094940 109134 730 5953- 8930 7269

10132 10153 -0021 16495029 956510 640 4647- 6971 5192

Average of Peak Concentrations = 660

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 44439946 944122 63 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 274 of 323

Data File vr479510d

Date 09-OCT-2012 0147

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 275 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1309971-A

Matrix vf479496dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2208

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

88 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 276 of 323

Data File vf479496d Report Date 09-Oct-2012 0319

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479496dLab Smp Id MB 460-1309971-a Inj Date 08-OCT-2012 2208 Operator Inst ID PESTGC9iSmp Info MB 460-1309971-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 24 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11484 11515 -0031 23517325 884233 59 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 277 of 323

Data File vf479496d

Date 08-OCT-2012 2208

Client ID Instrument PESTGC9i

Sample Info MB 460-1309971-a Operator

10162012Page 278 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1309971-A

Matrix vr479496dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2208

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

97 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 279 of 323

Data File vr479496d Page 1 Report Date 09-Oct-2012 0319

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479496dLab Smp Id MB 460-1309971-a Inj Date 08-OCT-2012 2208 Operator Inst ID PESTGC9iSmp Info MB 460-1309971-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 24 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 45589434 968543 64 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 280 of 323

Data File vr479496d

Date 08-OCT-2012 2208

Client ID Instrument PESTGC9i

Sample Info MB 460-1309971-a Operator

10162012Page 281 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-1311371

Matrix vf479492dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10082012 1814Sample wtvol

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

114 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 282 of 323

Data File vf479492d Page 1 Report Date 09-Oct-2012 0317

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479492dLab Smp Id piblk-sgpiblk_00013 Inj Date 08-OCT-2012 1814 Operator Inst ID PESTGC9iSmp Info sgpiblk_00013Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 20 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11496 11515 -0019 6086041 228830 15 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 283 of 323

Data File vf479492d

Date 08-OCT-2012 1814

Client ID Instrument PESTGC9i

Sample Info sgpiblk_00013 Operator

10162012Page 284 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-1311371

Matrix vr479492dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10082012 1814Sample wtvol

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

114 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 285 of 323

Data File vr479492d Report Date 09-Oct-2012 0317

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479492dLab Smp Id piblk-sgpiblk_00013 Inj Date 08-OCT-2012 1814 Operator Inst ID PESTGC9iSmp Info sgpiblk_00013Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 20 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 10738471 228138 15 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 286 of 323

Data File vr479492d

Date 08-OCT-2012 1814

Client ID Instrument PESTGC9i

Sample Info sgpiblk_00013 Operator

10162012Page 287 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-13113718

Matrix vf479509dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10092012 0131Sample wtvol

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

122 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 288 of 323

Data File vf479509d Report Date 09-Oct-2012 0313

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479509dLab Smp Id SGPIBLK_00013 Inj Date 09-OCT-2012 0131 Operator Inst ID PESTGC9iSmp Info SGPIBLK_00013Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 39 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11487 11515 -0028 6469383 243244 16 8000- 12000 10000(a)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 289 of 323

Data File vf479509d

Date 09-OCT-2012 0131

Client ID Instrument PESTGC9i

Sample Info SGPIBLK_00013 Operator

10162012Page 290 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-13113718

Matrix vr479509dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10092012 0131Sample wtvol

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

102 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 291 of 323

Data File vr479509d Report Date 09-Oct-2012 0306

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479509dLab Smp Id SGPIBLK_00013 Inj Date 09-OCT-2012 0131 Operator Inst ID PESTGC9iSmp Info SGPIBLK_00013Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 39 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 9634357 204681 14 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 292 of 323

Data File vr479509d

Date 09-OCT-2012 0131

Client ID Instrument PESTGC9i

Sample Info SGPIBLK_00013 Operator

10162012Page 293 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1309972-A

Matrix vf479497dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2224

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 507

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 557

RECCAS NO LIMITSQSURROGATE

84 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 294 of 323

Data File vf479497d Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479497dLab Smp Id LCS 460-1309972-a Inj Date 08-OCT-2012 2224 Operator Inst ID PESTGC9iSmp Info LCS 460-1309972-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 25 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2926 2961 -0035 10792080 105056 700 8000- 12000 10000

3596 3641 -0045 23726579 112379 750 16892- 25338 21985

4040 4085 -0045 9881475 113398 760 6889- 10334 9156

4437 4479 -0042 42082916 111596 740 30481- 45721 38994

4683 4722 -0039 19556228 118847 790 13320- 19980 18121

5181 5158 0023 7863050 804795 540 7564- 11346 7286

5572 5542 0030 6208245 517785 340 9332- 13998 5753

5713 5752 -0039 14198514 116895 780 9784- 14675 13156

Average of Peak Concentrations = 680

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7711 7756 -0045 26515963 119947 800 8000- 12000 10000(M)

10162012Page 295 of 323

Data File vf479497d Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8168 8215 -0047 29809525 118800 790 9103- 13655 11242

9026 9084 -0058 46049501 124909 830 14090- 21136 17367

9283 9332 -0049 20194161 124344 830 6105- 9158 7616

9408 9454 -0046 11340121 128654 860 3460- 5190 4277

9864 9901 -0037 20709127 122354 820 6444- 9666 7810

10623 10616 0007 8913638 423178 280 7926- 11889 3362

11063 11086 -0023 8650385 110095 730 2968- 4452 3262

Average of Peak Concentrations = 740

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11484 11515 -0031 22216113 835308 56 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 296 of 323

Data File vf479497d

Date 08-OCT-2012 2224

Client ID Instrument PESTGC9i

Sample Info LCS 460-1309972-a Operator

10162012Page 297 of 323

Manual Integration Report

Data File vf479497dInj Date and Time 08-OCT-2012 2224Instrument ID PESTGC9iClient ID Compound 27 Aroclor-1260CAS 11096-82-5Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 776

Manual Integration Results

RT 771

Response 26515963

Amount 111428

Conc 74000

Manually Integrated By diazcManual Integration Reason

10162012Page 298 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1309972-A

Matrix vr479497dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2224

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 483

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 573

RECCAS NO LIMITSQSURROGATE

91 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 299 of 323

Data File vr479497d Page 1 Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479497dLab Smp Id LCS 460-1309972-a Inj Date 08-OCT-2012 2224 Operator Inst ID PESTGC9iSmp Info LCS 460-1309972-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 25 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2058 2085 -0027 15080112 945502 630 8000- 12000 10000(M)

2502 2527 -0025 26928755 988901 660 13324- 19985 17857

2750 2777 -0027 19042665 106070 710 9975- 14963 12628

3103 3130 -0027 59594211 100167 670 29367- 44051 39518

3301 3330 -0029 23808984 103998 690 11758- 17638 15788

3694 3685 0009 14297782 603352 400 11464- 17196 9481

4013 4043 -0030 24245185 108176 720 11819- 17728 16078

4188 4191 -0003 10255607 100963 670 5577- 8366 6801

Average of Peak Concentrations = 640

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6048 6072 -0024 36196886 110771 740 8000- 12000 10000

10162012Page 300 of 323

Data File vr479497d Page 2 Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6500 6522 -0022 67525585 111673 740 14654- 21981 18655

6943 6964 -0021 64479188 116279 780 14108- 21162 17813

7142 7165 -0023 33072749 109644 730 7567- 11351 9137

7578 7602 -0024 30577540 112984 750 7053- 10579 8448

8864 8893 -0029 38421619 111797 740 9199- 13799 10615

9083 9115 -0032 26202367 123818 820 5953- 8930 7239

10138 10153 -0015 20706585 120073 800 4647- 6971 5721

Average of Peak Concentrations = 760

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 42991277 913346 61 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 301 of 323

Data File vr479497d

Date 08-OCT-2012 2224

Client ID Instrument PESTGC9i

Sample Info LCS 460-1309972-a Operator

10162012Page 302 of 323

Manual Integration Report

Data File vr479497dInj Date and Time 08-OCT-2012 2224Instrument ID PESTGC9iClient ID Compound 21 Aroclor-1016CAS 12674-11-2Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 208

Manual Integration Results

RT 206

Response 15080112

Amount 96644

Conc 64000

Manually Integrated By diazcManual Integration Reason

10162012Page 303 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCSD 460-1309973-A

Matrix vf479498dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2239

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 516

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 583

RECCAS NO LIMITSQSURROGATE

99 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 304 of 323

Data File vf479498d Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479498dLab Smp Id LCSd 460-1309973-a Inj Date 08-OCT-2012 2239 Operator Inst ID PESTGC9iSmp Info LCSd 460-1309973-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 26 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2925 2961 -0036 10994509 107027 710 8000- 12000 10000

3594 3641 -0047 24222192 114726 760 16892- 25338 22031

4039 4085 -0046 9969671 114410 760 6889- 10334 9068

4435 4479 -0044 43128755 114369 760 30481- 45721 39228

4680 4722 -0042 19946065 121217 810 13320- 19980 18142

5177 5158 0019 7960960 814816 540 7564- 11346 7241

5569 5542 0027 6392667 533166 360 9332- 13998 5814

5711 5752 -0041 14546887 119763 800 9784- 14675 13231

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7708 7756 -0048 27193660 123013 820 8000- 12000 10000(M)

10162012Page 305 of 323

Data File vf479498d Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8164 8215 -0051 30632211 122078 810 9103- 13655 11264

9022 9084 -0062 47541251 128955 860 14090- 21136 17482

9278 9332 -0054 21062846 129693 860 6105- 9158 7745

9404 9454 -0050 11787377 133728 890 3460- 5190 4335

9862 9901 -0039 21547760 127309 850 6444- 9666 7924

10618 10616 0002 10677528 506919 340 7926- 11889 3926

11062 11086 -0024 9277293 118074 790 2968- 4452 3412

Average of Peak Concentrations = 780

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11482 11515 -0033 26307958 989158 66 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 306 of 323

Data File vf479498d

Date 08-OCT-2012 2239

Client ID Instrument PESTGC9i

Sample Info LCSd 460-1309973-a Operator

10162012Page 307 of 323

Manual Integration Report

Data File vf479498dInj Date and Time 08-OCT-2012 2239Instrument ID PESTGC9iClient ID Compound 27 Aroclor-1260CAS 11096-82-5Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 776

Manual Integration Results

RT 771

Response 27193660

Amount 116693

Conc 78000

Manually Integrated By diazcManual Integration Reason

10162012Page 308 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCSD 460-1309973-A

Matrix vr479498dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2239

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 497

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 595

RECCAS NO LIMITSQSURROGATE

108 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 309 of 323

Data File vr479498d Page 1 Report Date 09-Oct-2012 0321

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479498dLab Smp Id LCSd 460-1309973-a Inj Date 08-OCT-2012 2239 Operator Inst ID PESTGC9iSmp Info LCSd 460-1309973-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 26 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2058 2085 -0027 15401465 965650 640 8000- 12000 10000(M)

2501 2527 -0026 27477458 100905 670 13324- 19985 17841

2750 2777 -0027 19458638 108387 720 9975- 14963 12634

3102 3130 -0028 60672366 101979 680 29367- 44051 39394

3299 3330 -0031 24206974 105737 700 11758- 17638 15717

3679 3685 -0006 17478185 737562 490 11464- 17196 11348

4012 4043 -0031 24592091 109724 730 11819- 17728 15967

4189 4191 -0002 9970290 981538 650 5577- 8366 6474

Average of Peak Concentrations = 660

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6047 6072 -0025 36957605 113099 750 8000- 12000 10000

10162012Page 310 of 323

Data File vr479498d Page 2 Report Date 09-Oct-2012 0321

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6498 6522 -0024 69036402 114172 760 14654- 21981 18680

6940 6964 -0024 66037968 119090 790 14108- 21162 17869

7140 7165 -0025 33956993 112575 750 7567- 11351 9188

7575 7602 -0027 31643763 116923 780 7053- 10579 8562

8861 8893 -0032 40016219 116437 780 9199- 13799 10828

9080 9115 -0035 27744305 131104 870 5953- 8930 7507

10136 10153 -0017 22040150 127806 850 4647- 6971 5964

Average of Peak Concentrations = 790

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10612 10624 -0012 50942327 108226 72 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 311 of 323

Data File vr479498d

Date 08-OCT-2012 2239

Client ID Instrument PESTGC9i

Sample Info LCSd 460-1309973-a Operator

10162012Page 312 of 323

Manual Integration Report

Data File vr479498dInj Date and Time 08-OCT-2012 2239Instrument ID PESTGC9iClient ID Compound 21 Aroclor-1016CAS 12674-11-2Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 208

Manual Integration Results

RT 206

Response 15401465

Amount 99401

Conc 66000

Manually Integrated By diazcManual Integration Reason

10162012Page 313 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GC SEMI VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

PESTGC9

129926

Start Date

End Date 09302012 2043

09302012 1530

RINSE 460-1299261 CLP-2 053(mm)109302012 1530

RINSE 460-1299261 CLP-1 053(mm)109302012 1530

RINSE 460-1299262 CLP-2 053(mm)109302012 1546

RINSE 460-1299262 CLP-1 053(mm)109302012 1546

ZZZZZ CLP-2 053(mm)109302012 1602

ZZZZZ CLP-1 053(mm)109302012 1602

ZZZZZ CLP-2 053(mm)109302012 1617

ZZZZZ CLP-1 053(mm)109302012 1617

ZZZZZ CLP-2 053(mm)109302012 1633

ZZZZZ CLP-1 053(mm)109302012 1633

ZZZZZ CLP-2 053(mm)109302012 1649

ZZZZZ CLP-1 053(mm)109302012 1649

IC 460-1299267 CLP-2 053(mm)109302012 1704 vf479200d

IC 460-1299267 CLP-1 053(mm)109302012 1704 vr479200d

IC 460-1299268 CLP-2 053(mm)109302012 1720 vf479201d

IC 460-1299268 CLP-1 053(mm)109302012 1720 vr479201d

IC 460-1299269 CLP-2 053(mm)109302012 1735 vf479202d

IC 460-1299269 CLP-1 053(mm)109302012 1735 vr479202d

IC 460-12992610 CLP-2 053(mm)109302012 1751 vf479203d

IC 460-12992610 CLP-1 053(mm)109302012 1751 vr479203d

IC 460-12992611 CLP-2 053(mm)109302012 1807 vf479204d

IC 460-12992611 CLP-1 053(mm)109302012 1807 vr479204d

IC 460-12992612 CLP-2 053(mm)109302012 1822 vf479205d

IC 460-12992612 CLP-1 053(mm)109302012 1822 vr479205d

IC 460-12992613 CLP-2 053(mm)109302012 1838 vf479206d

IC 460-12992613 CLP-1 053(mm)109302012 1838 vr479206d

IC 460-12992614 CLP-2 053(mm)109302012 1854 vf479207d

IC 460-12992614 CLP-1 053(mm)109302012 1854 vr479207d

IC 460-12992615 CLP-2 053(mm)109302012 1909 vf479208d

IC 460-12992615 CLP-1 053(mm)109302012 1909 vr479208d

IC 460-12992616 CLP-2 053(mm)109302012 1925 vf479209d

IC 460-12992616 CLP-1 053(mm)109302012 1925 vr479209d

IC 460-12992617 CLP-2 053(mm)109302012 1940

IC 460-12992617 CLP-1 053(mm)109302012 1940

IC 460-12992618 CLP-2 053(mm)109302012 1956

IC 460-12992618 CLP-1 053(mm)109302012 1956

ZZZZZ CLP-2 053(mm)109302012 2011

ZZZZZ CLP-1 053(mm)109302012 2011

ZZZZZ CLP-2 053(mm)109302012 2027

ZZZZZ CLP-1 053(mm)109302012 2027

ZZZZZ CLP-2 053(mm)109302012 2043

ZZZZZ CLP-1 053(mm)109302012 2043

8082

10162012Page 314 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GC SEMI VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

PESTGC9

131137

Start Date

End Date 10092012 0147

10082012 1814

PIBLK 460-1311371 CLP-2 053(mm)110082012 1814 vf479492d

PIBLK 460-1311371 CLP-1 053(mm)110082012 1814 vr479492d

CCVRT 460-1311372 CLP-2 053(mm)110082012 1830 vf479493d

CCVRT 460-1311372 CLP-1 053(mm)110082012 1830 vr479493d

ZZZZZ CLP-2 053(mm)110082012 2137

ZZZZZ CLP-1 053(mm)110082012 2137

ZZZZZ CLP-2 053(mm)110082012 2152

ZZZZZ CLP-1 053(mm)110082012 2152

MB 460-1309971-A CLP-2 053(mm)110082012 2208 vf479496d

MB 460-1309971-A CLP-1 053(mm)110082012 2208 vr479496d

LCS 460-1309972-A CLP-2 053(mm)110082012 2224 vf479497d

LCS 460-1309972-A CLP-1 053(mm)110082012 2224 vr479497d

LCSD 460-1309973-A CLP-2 053(mm)110082012 2239 vf479498d

LCSD 460-1309973-A CLP-1 053(mm)110082012 2239 vr479498d

ZZZZZ CLP-2 053(mm)110082012 2255

ZZZZZ CLP-1 053(mm)110082012 2255

ZZZZZ CLP-2 053(mm)110082012 2311

ZZZZZ CLP-1 053(mm)110082012 2311

ZZZZZ CLP-2 053(mm)110082012 2326

ZZZZZ CLP-1 053(mm)110082012 2326

ZZZZZ CLP-2 053(mm)110082012 2342

ZZZZZ CLP-1 053(mm)110082012 2342

ZZZZZ CLP-2 053(mm)110082012 2358

ZZZZZ CLP-1 053(mm)110082012 2358

ZZZZZ CLP-2 053(mm)110092012 0013

ZZZZZ CLP-1 053(mm)110092012 0013

460-45537-1 WC-17338-100512-MW14-MM-251

CLP-2 053(mm)110092012 0029 vf479505d

460-45537-1 WC-17338-100512-MW14-MM-251

CLP-1 053(mm)110092012 0029 vr479505d

460-45537-2 WC-17338-100512-MW101-MM-252

CLP-2 053(mm)110092012 0045 vf479506d

460-45537-2 WC-17338-100512-MW101-MM-252

CLP-1 053(mm)110092012 0045 vr479506d

ZZZZZ CLP-2 053(mm)110092012 0100

ZZZZZ CLP-1 053(mm)110092012 0100

ZZZZZ CLP-2 053(mm)110092012 0116

ZZZZZ CLP-1 053(mm)110092012 0116

PIBLK 460-13113718 CLP-2 053(mm)110092012 0131 vf479509d

PIBLK 460-13113718 CLP-1 053(mm)110092012 0131 vr479509d

CCV 460-13113719 CLP-2 053(mm)110092012 0147 vf479510d

CCV 460-13113719 CLP-1 053(mm)110092012 0147 vr479510d

8082

10162012Page 315 of 323

10162012Page 316 of 323

10162012Page 317 of 323

10162012Page 318 of 323

10162012Page 319 of 323

Lab Name Job No

SDG No

GC SEMI VOA BATCH WORKSHEET

460-45537-1

Batch Number Batch AnalystBatch Start Date

Batch End Date

Wu Huachi

100812 1800

100812 0754130997

Batch Method

TestAmerica Edison

3510C

Lab Sample ID Client Sample ID Method Chain Basis ReceivedpH InitialAmount FinalAmount OP_PCBSP 00024 OPPSTPCBSU 00021

AnalysisComment

7 1000 mL 5 mL 50 uL Acid Cleaning_UP

MB 460-1309971 3510C 8082

7 1000 mL 5 mL 50 uL 50 uL Acid Cleaning_UP

LCS 460-1309972

3510C 8082

7 1000 mL 5 mL 50 uL 50 uL Acid Cleaning_UP

LCSD 460-1309973

3510C 8082

WC-17338-100512-MW14-MM-251

7 980 mL 5 mL 50 uL Acid Cleaning_UP

460-45537-E-1 3510C 8082 T

WC-17338-100512-MW101-MM-252

7 990 mL 5 mL 50 uL Acid Cleaning_UP

460-45537-E-2 3510C 8082 T

Batch Notes

Batch Comment 8082Acid Cleaning_up Lot 20042

Persons name who did the concentration Wuh

Exchange Solvent Lot 6383

Exchange Solvent Name Hexane

Final Concentrator Volume 5 mL

N-evap temperature 35 Degrees C

Na2SO4 Lot Number 213204

Prep Solvent Lot 14764

Prep Solvent Name Mecl2

Prep Solvent Volume Used 180 ml mL

Persons name who did the prep Wuh

Persons name who witnessed reagent drop HCP

Basis Basis Description

T TotalNA

Page 1 of 18082

10162012Page 320 of 323

Shipping and

Receiving

Documents

10162012Page 321 of 323

10162012Page 322 of 323

Login Sample Receipt Checklist

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Login Number 45537

Question Answer Comment

Creator Hall Alonzo

List Source TestAmerica Edison

List Number 1

NARadioactivity wasnt checked or is lt= background as measured by a survey

meter

NAThe coolers custody seal if present is intact Not present

TrueSample custody seals if present are intact

TrueThe cooler or samples do not appear to have been compromised or

tampered with

TrueSamples were received on ice

TrueCooler Temperature is acceptable

TrueCooler Temperature is recorded 32deg C IR 2

TrueCOC is present

TrueCOC is filled out in ink and legible

TrueCOC is filled out with all pertinent information

TrueIs the Field Samplers name present on COC

TrueThere are no discrepancies between the containers received and the COC

TrueSamples are received within Holding Time

TrueSample containers have legible labels

TrueContainers are not broken or leaking

TrueSample collection datetimes are provided

TrueAppropriate sample containers are used

TrueSample bottles are completely filled

TrueSample Preservation Verified

TrueThere is sufficient vol for all requested analyses incl any requested

MSMSDs

TrueContainers requiring zero headspace have no headspace or bubble is

lt6mm (14)

NAMultiphasic samples are not present

NASamples do not require splitting or compositing

NAResidual Chlorine Checked No analysis requiring residual chlorine check

assigned

TestAmerica Edison 10162012Page 323 of 323

  • Cover Title Page
  • Table of Contents
  • Data Summaries
    • Report Narrative
    • Sample Summary
    • Executive Summary
    • Method Summary
    • Method Analyst Summary
    • Sample Datasheets
    • Surrogate Summary
    • QC Data Summary
    • Data Qualifiers
    • QC Association Summary
    • Lab Chronicle
      • Organic Sample Data
        • GCMS VOA
          • Method 8260 DEL
            • Method 8260 DEL QC Summary
            • Method 8260 DEL Sample Data
            • Standards Data
              • Method 8260 DEL ICAL Data
              • Method 8260 DEL CCAL Data
                • Raw QC Data
                  • Method 8260 DEL Tune Data
                  • Method 8260 DEL Blank Data
                  • Method 8260 DEL LCSLCSD Data
                  • Method 8260 DEL MSMSD Data
                    • Method 8260 DEL Run Logs
                    • Method 8260 DEL Prep Data
                        • GC Semi VOA
                          • Method 8082 - Delaware
                            • Method 8082 - Delaware QC Summary
                            • Method 8082 - Delaware Sample Data
                            • Standards Data
                              • Method 8082 - Delaware ICAL Data
                              • Method 8082 - Delaware CCAL Data
                                • Raw QC Data
                                  • Method 8082 - Delaware Blank Data
                                  • Method 8082 - Delaware LCSLCSD Data
                                    • Method 8082 - Delaware Run Logs
                                    • Method 8082 - Delaware Prep Data
                                      • Shipping and Receiving Documents
                                        • Client Chain of Custody
                                        • Sample Receipt Checklist
Page 2: J45537-1 Nj Full Package Final Report

Table of ContentsCover Title Page 1

Data Summaries 4

Report Narrative 4

Sample Summary 5

Executive Summary 6

Method Summary 7

Method Analyst Summary 8

Sample Datasheets 9

Surrogate Summary 22

QC Data Summary 24

Data Qualifiers 35

QC Association Summary 36

Lab Chronicle 37

Organic Sample Data 39

GCMS VOA 39

Method 8260 DEL 39Method 8260 DEL QC Summary 40Method 8260 DEL Sample Data 51Standards Data 72

Method 8260 DEL ICAL Data 72Method 8260 DEL CCAL Data 96

Raw QC Data 106Method 8260 DEL Tune Data 106Method 8260 DEL Blank Data 114Method 8260 DEL LCSLCSD Data 119Method 8260 DEL MSMSD Data 124

10162012Page 2 of 323

Table of ContentsMethod 8260 DEL Run Logs 134Method 8260 DEL Prep Data 136

GC Semi VOA 140

Method 8082 - Delaware 140Method 8082 - Delaware QC Summary 141Method 8082 - Delaware Sample Data 151Standards Data 163

Method 8082 - Delaware ICAL Data 163Method 8082 - Delaware CCAL Data 256

Raw QC Data 276Method 8082 - Delaware Blank Data 276Method 8082 - Delaware LCSLCSD Data 294

Method 8082 - Delaware Run Logs 314Method 8082 - Delaware Prep Data 316

Shipping and Receiving Documents 321

Client Chain of Custody 322

Sample Receipt Checklist 323

10162012Page 3 of 323

CASE NARRATIVE

Client Conestoga-Rovers amp Associates Inc

Project 17338-TO4-2012 RACER GM Wilmington

Report Number 460-45537-1

This case narrative is in the form of an exception report where only the anomalies related to this report method specific performance

andor QAQC issues are discussed If there are no issues to report this narrative will include a statement that documents that there are

no relevant data issues

It should be noted that samples with elevated Reporting Limits (RLs) as a result of a dilution may not be able to satisfy customer reporting

limits in some cases Such increases in the RLs are unavoidable but acceptable consequence of sample dilution that enables

quantification of target analytes or interferences which exceed the calibration range of the instrument

Calculations are performed before rounding to avoid round-off errors in calculated results

All holding times were met and proper preservation noted for the methods performed on these samples unless otherwise detailed in the

individual sections below

RECEIPT

The samples were received on 10052012 710 PM the samples arrived in good condition properly preserved and on ice The

temperature of the coolers at receipt was 32 C

Note All samples which require thermal preservation are considered acceptable if the arrival temperature is within 2C of the required

temperature or method specified range For samples with a specified temperature of 4C samples with a temperature ranging from just

above freezing temperature of water to 6C shall be acceptable Samples that are hand delivered immediately following collection may not

meet these criteria however they will be deemed acceptable according to NELAC standards if there is evidence that the chilling process

has begun such as arrival on ice etc

POLYCHLORINATED BIPHENYLS (PCBS)

Samples 460-45537-1 and 460-45537-2 were analyzed for polychlorinated biphenyls (PCBs) in accordance with EPA SW-846 Method

8082DEL The samples were prepared on 10082012 and analyzed on 10092012

No difficulties were encountered during the PCBs analyses

All quality control parameters were within the acceptance limits

VOLATILE ORGANIC COMPOUNDS (GC-MS)

Samples 460-45537-1 through 460-45537-3 were analyzed for volatile organic compounds (GC-MS) in accordance with EPA SW-846

Method 8260B The samples were analyzed on 10112012 and 10122012

The matrix spike matrix spike duplicate (MSMSD) recoveries for batch 131656 were outside control limits 12-Dibromo-3-chloropropane

The MSD recoveries were also outside control limits for trans-13-Dichloropropene and Methyl tert-butyl ether The associated laboratory

control sample (LCS) recoveries met acceptance criteria

12-Dibromo-3-Chloropropane failed the recovery criteria high for the MS of sample 460-45537-2 in batch 460-131656

12-Dibromo-3-Chloropropane Methyl tert-butyl ether and trans-13-Dichloropropene failed the recovery criteria high for the MSD of

sample 460-45537-2 in batch 460-131656

Refer to the QC report for details

No other difficulties were encountered during the volatiles analyses

All other quality control parameters were within the acceptance limits

10162012Page 4 of 323

SAMPLE SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample IDLab Sample ID Client Matrix Sampled Received

DateTime DateTime

460-45537-1 WC-17338-100512-MW14-MM-2

51

Water 10052012 1000 10052012 1910

460-45537-2 WC-17338-100512-MW101-MM-

252

Water 10052012 1230 10052012 1910

460-45537-3TB TB-17338-100512-253 Water 10052012 0000 10052012 1910

TestAmerica Edison 10162012Page 5 of 323

EXECUTIVE SUMMARY - Detections

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Analyte Result

Reporting

Limit Units Method

Lab Sample ID Client Sample ID

Qualifier

460-45537-1 WC-17338-100512-MW14-MM-251

10 ugL 8260B017 JMethyl tert-butyl ether

10 ugL 8260B017 JToluene

10 ugL 8260B028 JTetrachloroethene

460-45537-2 WC-17338-100512-MW101-MM-252

10 ugL 8260B020 JMethyl tert-butyl ether

460-45537-3TB TB-17338-100512-253

10 ugL 8260B074 JMethylene Chloride

10 ugL 8260B0096 JChloroform

TestAmerica Edison 10162012Page 6 of 323

METHOD SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Preparation MethodMethodLab LocationDescription

Matrix Water

Volatile Organics (GCMS) TAL EDI SW846 8260B

Purge and Trap TAL EDI SW846 5030B

Polychlorinated Biphenyls (PCBs) (GC) TAL EDI SW846 8082

Liquid-Liquid Extraction (Separatory Funnel) TAL EDI SW846 3510C

Lab References

TAL EDI = TestAmerica Edison

Method References

SW846 = Test Methods For Evaluating Solid Waste PhysicalChemical Methods Third Edition November 1986 And Its Updates

TestAmerica Edison 10162012Page 7 of 323

METHOD ANALYST SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Method Analyst Analyst ID

Boykin Kenneth KBSW846 8260B

Boykin Carol B CBBSW846 8082

TestAmerica Edison

10162012Page 8 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

017 J 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

017 J 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

028 J 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 9 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

99 70 - 1304-Bromofluorobenzene

96 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 10 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 11 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

020 J 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 12 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

98 70 - 1304-Bromofluorobenzene

97 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 13 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 14 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

074 J 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

014 U 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0096 J 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 15 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

99 70 - 1304-Bromofluorobenzene

97 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 16 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 17 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0029

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type PRIMARY

980 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

013 U 051013PCB-1016

029 U 051029PCB-1221

012 U 051012PCB-1232

012 U 051012PCB-1242

024 U 051024PCB-1248

017 U 051017PCB-1254

015 U 051015PCB-1260

Surrogate Rec Acceptance LimitsQualifier

83 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 18 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0029

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type SECONDARY

980 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Surrogate Rec Acceptance LimitsQualifier

82 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 19 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0045

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type PRIMARY

990 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

013 U 051013PCB-1016

028 U 051028PCB-1221

012 U 051012PCB-1232

012 U 051012PCB-1242

024 U 051024PCB-1248

017 U 051017PCB-1254

015 U 051015PCB-1260

Surrogate Rec Acceptance LimitsQualifier

52 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 20 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0045

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type SECONDARY

990 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Surrogate Rec Acceptance LimitsQualifier

50 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 21 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Surrogate Recovery Report

8260B Volatile Organics (GCMS)

Client Matrix Water

Lab Sample ID Client Sample ID

DCA TOL BFB

Rec Rec Rec

460-45537-1 WC-17338-100512-M

W14-MM-251

97 96 99

460-45537-2 WC-17338-100512-M

W101-MM-252

97 97 98

460-45537-3 TB-17338-100512-25

3

97 97 99

MB 460-1316564 99 96 95

LCS 460-1316563 96 99 97

460-45537-2 MS WC-17338-100512-M

W101-MM-252 MS

96 99 99

460-45537-2 MSD WC-17338-100512-M

W101-MM-252 MSD

96 99 97

Surrogate Acceptance Limits

DCA = 12-Dichloroethane-d4 (Surr) 70-130

TOL = Toluene-d8 (Surr) 70-130

BFB = 4-Bromofluorobenzene 70-130

TestAmerica Edison

10162012Page 22 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Surrogate Recovery Report

8082 Polychlorinated Biphenyls (PCBs) (GC)

Client Matrix Water

Lab Sample ID Client Sample ID

DCB1 DCB2

Rec Rec

460-45537-1 WC-17338-100512-M

W14-MM-251

82 83

460-45537-2 WC-17338-100512-M

W101-MM-252

52 50

MB 460-1309971-A 97 88

LCS 460-1309972-A 91 84

LCSD

460-1309973-A

108 99

Surrogate Acceptance Limits

DCB = DCB Decachlorobiphenyl 37-150

TestAmerica Edison

10162012Page 23 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-131656

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08981d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5MB 460-1316564

Analysis Date 10112012 2247

Analysis Batch

Prep Batch

Leach Batch

NA

NA

460-131656

Prep Date

Leach Date

10112012 2247

NA

Analyte RLMDLQualResult

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

014 U 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

TestAmerica Edison 10162012Page 24 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-131656

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08981d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5MB 460-1316564

Analysis Date 10112012 2247

Analysis Batch

Prep Batch

Leach Batch

NA

NA

460-131656

Prep Date

Leach Date

10112012 2247

NA

Analyte RLMDLQualResult

014 U 1001413-Dichlorobenzene

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance Limits

12-Dichloroethane-d4 (Surr) 99 70 - 130

4-Bromofluorobenzene 95 70 - 130

Toluene-d8 (Surr) 96 70 - 130

Method Blank TICs- Batch 460-131656

Cas Number Analyte RT Est Result Qual

Tentatively Identified Compound None

TestAmerica Edison 10162012Page 25 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10

Lab Control Sample - Batch 460-131656

Client Matrix

Lab Sample ID

Dilution

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08977d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5LCS 460-1316563

Analysis Date 10112012 2113

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Prep Date

Leach Date

10112012 2113

NA

Analyte QualLimit RecResultSpike Amount

200 210 105 74 - 128111-Trichloroethane

200 181 90 46 - 145Dichlorodifluoromethane

200 210 105 58 - 146Chloromethane

200 203 101 61 - 144Vinyl chloride

200 211 105 55 - 153Bromomethane

200 222 111 70 - 11612-Dibromo-3-Chloropropane

200 209 104 82 - 12212-Dichlorobenzene

200 190 95 69 - 147Trichlorofluoromethane

200 223 112 56 - 13911-Dichloroethene

200 211 106 80 - 12012-Dichloropropane

200 203 102 47 - 139112-Trichloro-122-trifluoroethane

200 250 125 45 - 156Acetone

200 218 109 58 - 139Carbon disulfide

200 220 110 50 - 151Methyl acetate

200 200 100 79 - 119Methylene Chloride

200 216 108 75 - 122trans-12-Dichloroethene

200 217 109 80 - 120Chlorodibromomethane

200 207 104 71 - 115Methyl tert-butyl ether

200 201 101 69 - 145Chloroethane

200 204 102 78 - 12211-Dichloroethane

200 211 106 80 - 120cis-12-Dichloroethene

200 214 107 65 - 1142-Butanone (MEK)

200 205 103 82 - 123Chloroform

200 206 103 79 - 126Ethylbenzene

200 208 104 58 - 133Cyclohexane

200 211 105 73 - 120Carbon tetrachloride

200 212 106 83 - 124Benzene

200 204 102 74 - 11812-Dichloroethane

200 212 106 78 - 119Trichloroethene

200 215 107 61 - 129Methylcyclohexane

200 214 107 79 - 119Dichlorobromomethane

200 216 108 80 - 120cis-13-Dichloropropene

200 214 107 53 - 1204-Methyl-2-pentanone (MIBK)

200 205 103 80 - 120Toluene

200 215 108 78 - 118trans-13-Dichloropropene

200 217 109 79 - 119112-Trichloroethane

200 210 105 68 - 139Tetrachloroethene

200 201 100 53 - 1212-Hexanone

200 215 107 78 - 11812-Dibromoethane

200 206 103 81 - 121Chlorobenzene

600 612 102 76 - 121Xylenes Total

200 207 104 69 - 112Styrene

200 217 109 73 - 123Bromoform

200 207 104 80 - 125Isopropylbenzene

200 210 105 74 - 1261122-Tetrachloroethane

200 204 102 81 - 12613-Dichlorobenzene

TestAmerica Edison 10162012Page 26 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10

Lab Control Sample - Batch 460-131656

Client Matrix

Lab Sample ID

Dilution

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08977d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5LCS 460-1316563

Analysis Date 10112012 2113

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Prep Date

Leach Date

10112012 2113

NA

Analyte QualLimit RecResultSpike Amount

200 204 102 83 - 12314-Dichlorobenzene

200 220 110 66 - 120124-Trichlorobenzene

Surrogate Rec Acceptance Limits

12-Dichloroethane-d4 (Surr) 96 70 - 130

4-Bromofluorobenzene 97 70 - 130

Toluene-d8 (Surr) 99 70 - 130

TestAmerica Edison 10162012Page 27 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Water

50

50

Client Matrix

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Client Matrix Water

e08985d

5 mL

5 mL

e08986d

5 mL

5 mL

Method 8260B

Preparation 5030B

VOAMS5

VOAMS5

460-45537-2

460-45537-2

MS Lab Sample ID

MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

10122012 0051

NA

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

10122012 0027

Analyte RPD LimitRPDLimit

Rec

MS MSD MS Qual MSD Qual

103 106 74 - 128 3 30111-Trichloroethane

87 90 46 - 145 4 30Dichlorodifluoromethane

102 101 58 - 146 0 30Chloromethane

104 105 61 - 144 0 30Vinyl chloride

107 105 55 - 153 2 30Bromomethane

121 121 70 - 116 0 30 F F12-Dibromo-3-Chloropropane

107 111 82 - 122 3 3012-Dichlorobenzene

121 100 69 - 147 19 30Trichlorofluoromethane

108 119 56 - 139 9 3011-Dichloroethene

111 110 80 - 120 0 3012-Dichloropropane

102 111 47 - 139 8 30112-Trichloro-122-trifluoroethane

99 101 45 - 156 2 30Acetone

113 119 58 - 139 5 30Carbon disulfide

100 101 50 - 151 1 30Methyl acetate

106 106 79 - 119 0 30Methylene Chloride

106 108 75 - 122 2 30trans-12-Dichloroethene

116 118 80 - 120 2 30Chlorodibromomethane

114 116 71 - 115 1 30 FMethyl tert-butyl ether

116 105 69 - 145 10 30Chloroethane

104 111 78 - 122 7 3011-Dichloroethane

105 109 80 - 120 4 30cis-12-Dichloroethene

111 114 65 - 114 3 302-Butanone (MEK)

108 113 82 - 123 4 30Chloroform

107 111 79 - 126 3 30Ethylbenzene

108 117 58 - 133 7 30Cyclohexane

105 110 73 - 120 5 30Carbon tetrachloride

106 114 83 - 124 7 30Benzene

107 109 74 - 118 2 3012-Dichloroethane

107 113 78 - 119 5 30Trichloroethene

115 121 61 - 129 5 30Methylcyclohexane

113 116 79 - 119 3 30Dichlorobromomethane

109 115 80 - 120 5 30cis-13-Dichloropropene

111 114 53 - 120 3 304-Methyl-2-pentanone (MIBK)

TestAmerica Edison 10162012Page 28 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Water

50

50

Client Matrix

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Client Matrix Water

e08985d

5 mL

5 mL

e08986d

5 mL

5 mL

Method 8260B

Preparation 5030B

VOAMS5

VOAMS5

460-45537-2

460-45537-2

MS Lab Sample ID

MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

10122012 0051

NA

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

10122012 0027

Analyte RPD LimitRPDLimit

Rec

MS MSD MS Qual MSD Qual

106 111 80 - 120 5 30Toluene

113 119 78 - 118 5 30 Ftrans-13-Dichloropropene

112 116 79 - 119 3 30112-Trichloroethane

110 116 68 - 139 5 30Tetrachloroethene

109 111 53 - 121 2 302-Hexanone

116 117 78 - 118 1 3012-Dibromoethane

107 111 81 - 121 3 30Chlorobenzene

106 110 76 - 121 3 30Xylenes Total

107 110 69 - 112 3 30Styrene

115 114 73 - 123 1 30Bromoform

107 111 80 - 125 4 30Isopropylbenzene

115 116 74 - 126 0 301122-Tetrachloroethane

106 110 81 - 126 4 3013-Dichlorobenzene

106 110 83 - 123 4 3014-Dichlorobenzene

110 119 66 - 120 8 30124-Trichlorobenzene

Surrogate Acceptance LimitsMS Rec MSD Rec

12-Dichloroethane-d4 (Surr) 96 96 70 - 130

4-Bromofluorobenzene 99 97 70 - 130

Toluene-d8 (Surr) 99 99 70 - 130

TestAmerica Edison 10162012Page 29 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10122012 0027 10122012 0051

Dilution Dilution50 50

Client Matrix Client Matrix Water

Method 8260B

Preparation 5030B

Units ugL460-45537-2 460-45537-2MS Lab Sample ID MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

Analysis Date

Prep Date

Leach Date

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

NA

Amount

Sample

Analyte ResultQual Amount ResultQual ResultQual

MS MSDMS Spike MSD Spike

0060 U 100 100 103 106111-Trichloroethane

022 U 100 100 865 896Dichlorodifluoromethane

010 U 100 100 102 101Chloromethane

014 U 100 100 104 105Vinyl chloride

018 U 100 100 107 105Bromomethane

040 U 100 100 121 121F F12-Dibromo-3-Chloropropane

021 U 100 100 107 11112-Dichlorobenzene

015 U 100 100 121 997Trichlorofluoromethane

0090 U 100 100 108 11911-Dichloroethene

0090 U 100 100 111 11012-Dichloropropane

0080 U 100 100 102 111112-Trichloro-122-trifluoroethane

27 U 100 100 986 101Acetone

013 U 100 100 113 119Carbon disulfide

034 U 100 100 100 101Methyl acetate

018 U 100 100 106 106Methylene Chloride

013 U 100 100 106 108trans-12-Dichloroethene

020 U 100 100 116 118Chlorodibromomethane

020 J 100 100 114 116 FMethyl tert-butyl ether

017 U 100 100 116 105Chloroethane

013 U 100 100 104 11111-Dichloroethane

018 U 100 100 105 109cis-12-Dichloroethene

23 U 100 100 111 1142-Butanone (MEK)

0080 U 100 100 108 113Chloroform

010 U 100 100 107 111Ethylbenzene

016 U 100 100 108 117Cyclohexane

0060 U 100 100 105 110Carbon tetrachloride

0080 U 100 100 106 114Benzene

019 U 100 100 107 10912-Dichloroethane

0090 U 100 100 107 113Trichloroethene

014 U 100 100 115 121Methylcyclohexane

012 U 100 100 113 116Dichlorobromomethane

018 U 100 100 109 115cis-13-Dichloropropene

099 U 100 100 111 1144-Methyl-2-pentanone (MIBK)

015 U 100 100 106 111Toluene

024 U 100 100 113 119 Ftrans-13-Dichloropropene

019 U 100 100 112 116112-Trichloroethane

010 U 100 100 110 116Tetrachloroethene

050 U 100 100 109 1112-Hexanone

028 U 100 100 116 11712-Dibromoethane

011 U 100 100 107 111Chlorobenzene

036 U 300 300 318 329Xylenes Total

012 U 100 100 107 110Styrene

019 U 100 100 115 114Bromoform

TestAmerica Edison 10162012Page 30 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10122012 0027 10122012 0051

Dilution Dilution50 50

Client Matrix Client Matrix Water

Method 8260B

Preparation 5030B

Units ugL460-45537-2 460-45537-2MS Lab Sample ID MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

Analysis Date

Prep Date

Leach Date

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

NA

Amount

Sample

Analyte ResultQual Amount ResultQual ResultQual

MS MSDMS Spike MSD Spike

0080 U 100 100 107 111Isopropylbenzene

016 U 100 100 115 1161122-Tetrachloroethane

014 U 100 100 106 11013-Dichlorobenzene

023 U 100 100 106 11014-Dichlorobenzene

034 U 100 100 110 119124-Trichlorobenzene

TestAmerica Edison 10162012Page 31 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-130997

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

vr479496d

1000 mL

5 mLUnits ugL

Method 8082

Preparation 3510C

PESTGC9MB 460-1309971-A

Analysis Date 10082012 2208

Analysis Batch

Prep Batch

Leach Batch NA

460-131137

460-130997

Prep Date Injection Volume

Leach Date

10082012 0755

NA PRIMARYColumn ID

Analyte RLMDLQualResult

013 U 050013PCB-1016

028 U 050028PCB-1221

012 U 050012PCB-1232

012 U 050012PCB-1242

024 U 050024PCB-1248

017 U 050017PCB-1254

015 U 050015PCB-1260

Surrogate Rec Acceptance Limits

DCB Decachlorobiphenyl 97 37 - 150

Surrogate Rec Acceptance Limits

DCB Decachlorobiphenyl 88 37 - 150

TestAmerica Edison 10162012Page 32 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Lab Control Sample

Lab Control Sample Duplicate Recovery Report - Batch 460-130997

10

10

Water

LCS Lab Sample ID

LCSD Lab Sample ID

Client Matrix

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

Client Matrix Water

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

ugL

vf479497d

1000 mL

5 mL

PRIMARY

vf479498d

1000 mL

5 mL

PRIMARY

ugL

Method 8082

Preparation 3510C

PESTGC9

PESTGC9

LCS 460-1309972-A

LCSD 460-1309973-A

Analysis Date

Prep Date

Leach Date

10082012 2224

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

Rec

103101 71 - 126 2 30PCB-1016

119115 73 - 130 4 30PCB-1260

Surrogate LCS Rec LCSD Rec Acceptance Limits

DCB Decachlorobiphenyl 91 108 37 - 150

Dilution

Dilution

Lab Control Sample

Lab Control Sample Duplicate Recovery Report - Batch 460-130997

10

10

Water

LCS Lab Sample ID

LCSD Lab Sample ID

Client Matrix

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

Client Matrix Water

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

ugL

vr479497d

1000 mL

5 mL

SECONDARY

vr479498d

1000 mL

5 mL

SECONDARY

ugL

Method 8082

Preparation 3510C

PESTGC9

PESTGC9

LCS 460-1309972-A

LCSD 460-1309973-A

Analysis Date

Prep Date

Leach Date

10082012 2224

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

Rec

9997 71 - 126 3 30PCB-1016

117111 73 - 130 5 30PCB-1260

Surrogate LCS Rec LCSD Rec Acceptance Limits

DCB Decachlorobiphenyl 84 99 37 - 150

TestAmerica Edison 10162012Page 33 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10082012 2224

Dilution Dilution10 10

Client Matrix

LCSD Lab Sample ID

Client Matrix Water

Laboratory Control

Laboratory Duplicate Data Report - Batch 460-130997

Method 8082

Preparation 3510C

Units ugLLCS 460-1309972-A LCSD 460-1309973-ALCS Lab Sample ID

Analysis Date

Prep Date

Leach Date

10082012 0755

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NANA

LCSD

ResultQual

LCS

ResultQual

LCSD Spike

Amount

LCS Spike

AmountAnalyte

516507500 500PCB-1016

595573500 500PCB-1260

Water

10082012 2224

Dilution Dilution10 10

Client Matrix

LCSD Lab Sample ID

Client Matrix Water

Laboratory Control

Laboratory Duplicate Data Report - Batch 460-130997

Method 8082

Preparation 3510C

Units ugLLCS 460-1309972-A LCSD 460-1309973-ALCS Lab Sample ID

Analysis Date

Prep Date

Leach Date

10082012 0755

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NANA

LCSD

ResultQual

LCS

ResultQual

LCSD Spike

Amount

LCS Spike

AmountAnalyte

497483500 500PCB-1016

583557500 500PCB-1260

TestAmerica Edison 10162012Page 34 of 323

DATA REPORTING QUALIFIERS

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Lab Section Qualifier Description

GCMS VOA

Indicates the analyte was analyzed for but not detectedU

MSMSD Recovery or RPD exceeds the control limitsF

Result is less than the RL but greater than or equal to the MDL and the

concentration is an approximate value

J

GC Semi VOA

Indicates the analyte was analyzed for but not detectedU

TestAmerica Edison 10162012Page 35 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

QC Association Summary

Lab Sample ID Client Sample ID Client Matrix Method Prep Batch

Report

Basis

GCMS VOA

Analysis Batch460-131656

Lab Control Sample Water 8260BLCS 460-1316563 T

Method Blank Water 8260BMB 460-1316564 T

WaterWC-17338-100512-MW14-MM-251 8260B460-45537-1 T

WaterWC-17338-100512-MW101-MM-252 8260B460-45537-2 T

Matrix Spike Water 8260B460-45537-2MS T

Matrix Spike Duplicate Water 8260B460-45537-2MSD T

WaterTB-17338-100512-253 8260B460-45537-3TB T

Report Basis

T = Total

GC Semi VOA

Prep Batch 460-130997

Lab Control Sample Water 3510CLCS 460-1309972-A T

Lab Control Sample Duplicate Water 3510CLCSD 460-1309973-A T

Method Blank Water 3510CMB 460-1309971-A T

WaterWC-17338-100512-MW14-MM-251 3510C460-45537-1 T

WaterWC-17338-100512-MW101-MM-252 3510C460-45537-2 T

Analysis Batch460-131137

Lab Control Sample Water 460-1309978082LCS 460-1309972-A T

Lab Control Sample Duplicate Water 460-1309978082LCSD 460-1309973-A T

Method Blank Water 460-1309978082MB 460-1309971-A T

Water 460-130997WC-17338-100512-MW14-MM-251 8082460-45537-1 T

Water 460-130997WC-17338-100512-MW101-MM-252 8082460-45537-2 T

Report Basis

T = Total

TestAmerica Edison

10162012Page 36 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Laboratory Chronicle

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1000

460-45537-1 WC-17338-100512-MW14-MM-251

P5030B 460-45537-A-1 460-131656 10112012 2341 KBTAL EDI1

A8260B 460-45537-A-1 460-131656 10112012 2341 KBTAL EDI1

P3510C 460-45537-E-1-B 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 460-45537-E-1-B 460-131137 460-130997 10092012 0029 CBBTAL EDI1

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 WC-17338-100512-MW101-MM-252

P5030B 460-45537-A-2 460-131656 10122012 0004 KBTAL EDI1

A8260B 460-45537-A-2 460-131656 10122012 0004 KBTAL EDI1

P3510C 460-45537-E-2-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 460-45537-E-2-A 460-131137 460-130997 10092012 0045 CBBTAL EDI1

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 MS WC-17338-100512-MW101-MM-252

P5030B 460-45537-C-2 MS 460-131656 10122012 0027 KBTAL EDI5

A8260B 460-45537-C-2 MS 460-131656 10122012 0027 KBTAL EDI5

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 MSD WC-17338-100512-MW101-MM-252

P5030B 460-45537-C-2 MSD 460-131656 10122012 0051 KBTAL EDI5

A8260B 460-45537-C-2 MSD 460-131656 10122012 0051 KBTAL EDI5

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 0000

460-45537-3 TB-17338-100512-253

P5030B 460-45537-A-3 460-131656 10112012 2317 KBTAL EDI1

A8260B 460-45537-A-3 460-131656 10112012 2317 KBTAL EDI1

A = Analytical Method P = Prep Method TestAmerica Edison

10162012Page 37 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Laboratory Chronicle

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

MB NA

P5030B MB 460-1316564 460-131656 10112012 2247 KBTAL EDI1

A8260B MB 460-1316564 460-131656 10112012 2247 KBTAL EDI1

P3510C MB 460-1309971-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 MB 460-1309971-A 460-131137 460-130997 10082012 2208 CBBTAL EDI1

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

LCS NA

P5030B LCS 460-1316563 460-131656 10112012 2113 KBTAL EDI1

A8260B LCS 460-1316563 460-131656 10112012 2113 KBTAL EDI1

P3510C LCS 460-1309972-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 LCS 460-1309972-A 460-131137 460-130997 10082012 2224 CBBTAL EDI1

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

LCSD NA

P3510C LCSD

460-1309973-A

460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 LCSD

460-1309973-A

460-131137 460-130997 10082012 2239 CBBTAL EDI1

Lab ReferencesTAL EDI = TestAmerica Edison

A = Analytical Method P = Prep Method TestAmerica Edison

10162012Page 38 of 323

Method 8260 DELVolatile Organics (GCMS) by Method

8260 (Delaware)

10162012Page 39 of 323

FORM II

GCMS VOA SURROGATE RECOVERY

Lab Name Job No 460-45537-1

SDG No

Matrix Water Level Low

TestAmerica Edison

GC Column (1) Rtx-VMS ID 018(mm)

Lab Sample IDClient Sample ID DCA TOL BFB

460-45537-1WC-17338-100512-MW14-MM-251

97 96 99

460-45537-2WC-17338-100512-MW101-MM-252

97 97 98

460-45537-3TB-17338-100512-253

97 97 99

MB 460-1316564 99 96 95

LCS 460-1316563 96 99 97

460-45537-2 MSWC-17338-100512-MW101-MM-252 MS

96 99 99

460-45537-2 MSDWC-17338-100512-MW101-MM-252 MSD

96 99 97

QC LIMITSQC LIMITSDCA = 12-Dichloroethane-d4 (Surr) 70-130

TOL = Toluene-d8 (Surr) 70-130

BFB = 4-Bromofluorobenzene 70-130

FORM II 8260B

Column to be used to flag recovery values

10162012Page 40 of 323

GCMS VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08977dWater

Lab ID LCS 460-1316563 Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

111-Trichloroethane 200 210 74-128105

Dichlorodifluoromethane 200 181 46-14590

Chloromethane 200 210 58-146105

Vinyl chloride 200 203 61-144101

Bromomethane 200 211 55-153105

12-Dibromo-3-Chloropropane 200 222 70-116111

12-Dichlorobenzene 200 209 82-122104

Trichlorofluoromethane 200 190 69-14795

11-Dichloroethene 200 223 56-139112

12-Dichloropropane 200 211 80-120106

112-Trichloro-122-trifluoroethane

200 203 47-139102

Acetone 200 250 45-156125

Carbon disulfide 200 218 58-139109

Methyl acetate 200 220 50-151110

Methylene Chloride 200 200 79-119100

trans-12-Dichloroethene 200 216 75-122108

Chlorodibromomethane 200 217 80-120109

Methyl tert-butyl ether 200 207 71-115104

Chloroethane 200 201 69-145101

11-Dichloroethane 200 204 78-122102

cis-12-Dichloroethene 200 211 80-120106

2-Butanone (MEK) 200 214 65-114107

Chloroform 200 205 82-123103

Ethylbenzene 200 206 79-126103

Cyclohexane 200 208 58-133104

Carbon tetrachloride 200 211 73-120105

Benzene 200 212 83-124106

12-Dichloroethane 200 204 74-118102

Trichloroethene 200 212 78-119106

Methylcyclohexane 200 215 61-129107

Dichlorobromomethane 200 214 79-119107

cis-13-Dichloropropene 200 216 80-120108

4-Methyl-2-pentanone (MIBK) 200 214 53-120107

Toluene 200 205 80-120103

trans-13-Dichloropropene 200 215 78-118108

112-Trichloroethane 200 217 79-119109

Tetrachloroethene 200 210 68-139105

2-Hexanone 200 201 53-121100

12-Dibromoethane 200 215 78-118107

Chlorobenzene 200 206 81-121103

Xylenes Total 600 612 76-121102

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 41 of 323

GCMS VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08977dWater

Lab ID LCS 460-1316563 Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

Styrene 200 207 69-112104

Bromoform 200 217 73-123109

Isopropylbenzene 200 207 80-125104

1122-Tetrachloroethane 200 210 74-126105

13-Dichlorobenzene 200 204 81-126102

14-Dichlorobenzene 200 204 83-123102

124-Trichlorobenzene 200 220 66-120110

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 42 of 323

GCMS VOA MATRIX SPIKE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08985dWater

Lab ID 460-45537-2 MS Client ID WC-17338-100512-MW101-MM-252 MS

TestAmerica Edison

LIMITS

COMPOUND

CONCENTRATION

REC

QC

REC

SAMPLE

CONCENTRATION

SPIKE

ADDED

(ugL) (ugL) (ugL)

MS MS

100 103 74-128111-Trichloroethane 1030060 U

100 865 46-145Dichlorodifluoromethane 87022 U

100 102 58-146Chloromethane 102010 U

100 104 61-144Vinyl chloride 104014 U

100 107 55-153Bromomethane 107018 U

100 121 70-11612-Dibromo-3-Chloropropane 121040 U F

100 107 82-12212-Dichlorobenzene 107021 U

100 121 69-147Trichlorofluoromethane 121015 U

100 108 56-13911-Dichloroethene 1080090 U

100 111 80-12012-Dichloropropane 1110090 U

100 102 47-139112-Trichloro-122-trifluoroethane

1020080 U

100 986 45-156Acetone 9927 U

100 113 58-139Carbon disulfide 113013 U

100 100 50-151Methyl acetate 100034 U

100 106 79-119Methylene Chloride 106018 U

100 106 75-122trans-12-Dichloroethene 106013 U

100 116 80-120Chlorodibromomethane 116020 U

100 114 71-115Methyl tert-butyl ether 114020 J

100 116 69-145Chloroethane 116017 U

100 104 78-12211-Dichloroethane 104013 U

100 105 80-120cis-12-Dichloroethene 105018 U

100 111 65-1142-Butanone (MEK) 11123 U

100 108 82-123Chloroform 1080080 U

100 107 79-126Ethylbenzene 107010 U

100 108 58-133Cyclohexane 108016 U

100 105 73-120Carbon tetrachloride 1050060 U

100 106 83-124Benzene 1060080 U

100 107 74-11812-Dichloroethane 107019 U

100 107 78-119Trichloroethene 1070090 U

100 115 61-129Methylcyclohexane 115014 U

100 113 79-119Dichlorobromomethane 113012 U

100 109 80-120cis-13-Dichloropropene 109018 U

100 111 53-1204-Methyl-2-pentanone (MIBK) 111099 U

100 106 80-120Toluene 106015 U

100 113 78-118trans-13-Dichloropropene 113024 U

100 112 79-119112-Trichloroethane 112019 U

100 110 68-139Tetrachloroethene 110010 U

100 109 53-1212-Hexanone 109050 U

100 116 78-11812-Dibromoethane 116028 U

100 107 81-121Chlorobenzene 107011 U

300 318 76-121Xylenes Total 106036 U

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 43 of 323

GCMS VOA MATRIX SPIKE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08985dWater

Lab ID 460-45537-2 MS Client ID WC-17338-100512-MW101-MM-252 MS

TestAmerica Edison

LIMITS

COMPOUND

CONCENTRATION

REC

QC

REC

SAMPLE

CONCENTRATION

SPIKE

ADDED

(ugL) (ugL) (ugL)

MS MS

100 107 69-112Styrene 107012 U

100 115 73-123Bromoform 115019 U

100 107 80-125Isopropylbenzene 1070080 U

100 115 74-1261122-Tetrachloroethane 115016 U

100 106 81-12613-Dichlorobenzene 106014 U

100 106 83-12314-Dichlorobenzene 106023 U

100 110 66-120124-Trichlorobenzene 110034 U

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 44 of 323

GCMS VOA MATRIX SPIKE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08986dWater

Lab ID 460-45537-2 MSD Client ID WC-17338-100512-MW101-MM-252

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

MSD MSD

100 106 30 74-128111-Trichloroethane 3106

100 896 30 46-145Dichlorodifluoromethane 490

100 101 30 58-146Chloromethane 0101

100 105 30 61-144Vinyl chloride 0105

100 105 30 55-153Bromomethane 2105

100 121 30 70-11612-Dibromo-3-Chloropropane 0121 F

100 111 30 82-12212-Dichlorobenzene 3111

100 997 30 69-147Trichlorofluoromethane 19100

100 119 30 56-13911-Dichloroethene 9119

100 110 30 80-12012-Dichloropropane 0110

100 111 30 47-139112-Trichloro-122-trifluoroethane

8111

100 101 30 45-156Acetone 2101

100 119 30 58-139Carbon disulfide 5119

100 101 30 50-151Methyl acetate 1101

100 106 30 79-119Methylene Chloride 0106

100 108 30 75-122trans-12-Dichloroethene 2108

100 118 30 80-120Chlorodibromomethane 2118

100 116 30 71-115Methyl tert-butyl ether 1116 F

100 105 30 69-145Chloroethane 10105

100 111 30 78-12211-Dichloroethane 7111

100 109 30 80-120cis-12-Dichloroethene 4109

100 114 30 65-1142-Butanone (MEK) 3114

100 113 30 82-123Chloroform 4113

100 111 30 79-126Ethylbenzene 3111

100 117 30 58-133Cyclohexane 7117

100 110 30 73-120Carbon tetrachloride 5110

100 114 30 83-124Benzene 7114

100 109 30 74-11812-Dichloroethane 2109

100 113 30 78-119Trichloroethene 5113

100 121 30 61-129Methylcyclohexane 5121

100 116 30 79-119Dichlorobromomethane 3116

100 115 30 80-120cis-13-Dichloropropene 5115

100 114 30 53-1204-Methyl-2-pentanone (MIBK) 3114

100 111 30 80-120Toluene 5111

100 119 30 78-118trans-13-Dichloropropene 5119 F

100 116 30 79-119112-Trichloroethane 3116

100 116 30 68-139Tetrachloroethene 5116

100 111 30 53-1212-Hexanone 2111

100 117 30 78-11812-Dibromoethane 1117

100 111 30 81-121Chlorobenzene 3111

300 329 30 76-121Xylenes Total 3110

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 45 of 323

GCMS VOA MATRIX SPIKE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08986dWater

Lab ID 460-45537-2 MSD Client ID WC-17338-100512-MW101-MM-252

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

MSD MSD

100 110 30 69-112Styrene 3110

100 114 30 73-123Bromoform 1114

100 111 30 80-125Isopropylbenzene 4111

100 116 30 74-1261122-Tetrachloroethane 0116

100 110 30 81-12613-Dichlorobenzene 4110

100 110 30 83-12314-Dichlorobenzene 4110

100 119 30 66-120124-Trichlorobenzene 8119

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 46 of 323

FORM IV

GCMS VOA METHOD BLANK SUMMARY

Lab Name

SDG No

Job No 460-45537-1TestAmerica Edison

Date Analyzed

GC Column ID

Instrument ID 10112012 2247

Rtx-VMS

NHeated Purge(YN)

VOAMS5

e08981dLab File ID Lab Sample ID MB 460-1316564

WaterMatrix

018(mm)

THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES

LAB SAMPLE ID

LAB

FILE ID DATE ANALYZEDCLIENT SAMPLE ID

10112012 2113e08977dLCS 460-1316563

10112012 2317e08982d460-45537-3TB-17338-100512-253

10112012 2341e08983d460-45537-1WC-17338-100512-MW14-MM-251

10122012 0004e08984d460-45537-2WC-17338-100512-MW101-MM-252

10122012 0027e08985d460-45537-2 MSWC-17338-100512-MW101-MM-252 MS

10122012 0051e08986d460-45537-2 MSDWC-17338-100512-MW101-MM-252 MSD

FORM IV 8260B

10162012Page 47 of 323

FORM V

BROMOFLUOROBENZENE (BFB)

Lab Name

SDG No

Job No 460-45537-1

Lab File ID

Instrument ID

e07834d

VOAMS5

09172012

0324

BFB Injection Date

BFB Injection Time

ME ION ABUNDANCE CRITERIA RELATIVEABUNDANCE

Analysis Batch No 128076

50 150 - 400 of mass 95 219

75 300 - 600 of mass 95 525

95 Base Peak 100 relative abundance 1000

96 50 - 90 of mass 95 64

173 Less than 20 of mass 174 00 (00)1

174 500 - 12000 of mass 95 796

175 50 - 90 of mass 174 66 (83)1

176 950 - 1010 of mass 174 761 (957)1

177 50 - 90 of mass 176 48 (63)2

1-Value is mass 174 2-Value is mass 176

THIS CHECK APPLIES TO THE FOLLOWING SAMPLES MS MSD BLANKS AND STANDARDS

GCMS VOA INSTRUMENT PERFORMANCE CHECK

TestAmerica Edison

CLIENT SAMPLE IDLAB

FILE IDLAB SAMPLE IDDATE

ANALYZEDTIME

ANALYZED

e07836d 09172012 0449IC 460-1280762

e07838d 09172012 0536IC 460-1280763

e07839d 09172012 0600ICIS 460-1280764

e07840d 09172012 0623IC 460-1280765

e07841d 09172012 0646IC 460-1280766

e07842d 09172012 0710IC 460-1280767

FORM V 8260B 10162012Page 48 of 323

FORM V

BROMOFLUOROBENZENE (BFB)

Lab Name

SDG No

Job No 460-45537-1

Lab File ID

Instrument ID

e08975d

VOAMS5

10112012

2008

BFB Injection Date

BFB Injection Time

ME ION ABUNDANCE CRITERIA RELATIVEABUNDANCE

Analysis Batch No 131656

50 150 - 400 of mass 95 218

75 300 - 600 of mass 95 518

95 Base Peak 100 relative abundance 1000

96 50 - 90 of mass 95 65

173 Less than 20 of mass 174 07 (07)1

174 500 - 12000 of mass 95 896

175 50 - 90 of mass 174 72 (80)1

176 950 - 1010 of mass 174 872 (973)1

177 50 - 90 of mass 176 53 (61)2

1-Value is mass 174 2-Value is mass 176

THIS CHECK APPLIES TO THE FOLLOWING SAMPLES MS MSD BLANKS AND STANDARDS

GCMS VOA INSTRUMENT PERFORMANCE CHECK

TestAmerica Edison

CLIENT SAMPLE IDLAB

FILE IDLAB SAMPLE IDDATE

ANALYZEDTIME

ANALYZED

e08976d 10112012 2050CCVIS 460-1316562

e08977d 10112012 2113LCS 460-1316563

e08981d 10112012 2247MB 460-1316564

TB-17338-100512-253 e08982d 10112012 2317460-45537-3

WC-17338-100512-MW14-MM-251

e08983d 10112012 2341460-45537-1

WC-17338-100512-MW101-MM-252

e08984d 10122012 0004460-45537-2

WC-17338-100512-MW101-MM-252 MS

e08985d 10122012 0027460-45537-2 MS

WC-17338-100512-MW101-MM-252 MSD

e08986d 10122012 0051460-45537-2 MSD

e08987d 10122012 0114CCV 460-13165610

FORM V 8260B 10162012Page 49 of 323

GCMS VOA INTERNAL STANDARD AREA AND RETENTION TIME SUMMARY

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVIS 460-1316562 Date Analyzed 10112012 2050

Lab File ID (Standard) e08976d

Instrument ID VOAMS5 GC Column Rtx-VMS ID 018(mm)

Heated Purge (YN) N

Calibration ID 17515

AREA RT AREA RT AREA RT

FB CBZ DCB

UPPER LIMIT

LOWER LIMIT

2625312

656328 578671

2314682

333917

1335668

360 695 10471224 HOUR STD

410

310

745

645

1097

997

1312656 1157341 667834

LAB SAMPLE ID CLIENT SAMPLE ID

LCS 460-1316563 1318918 1146590 683882 360 695 1047

MB 460-1316564 1238441 1084553 638826 360 695 1047

460-45537-3 TB-17338-100512-253 1280000 1135339 646856 359 695 1047

460-45537-1 WC-17338-100512-MW14-MM-251

1242225 1119807 641810 359 695 1047

460-45537-2 WC-17338-100512-MW101-MM-252

1247617 1105330 633816 360 695 1047

460-45537-2 MS WC-17338-100512-MW101-MM-252 MS

1234975 1102789 642491 359 695 1047

460-45537-2 MSD WC-17338-100512-MW101-MM-252 MSD

1296388 1119645 654839 360 695 1047

CCV 460-13165610 1274024 1125053 665092 359 695 1047

FB = Fluorobenzene

CBZ = Chlorobenzene-d5

DCB = 14-Dichlorobenzene-d4

Area Limit = 50-200 of internal standard area

RT Limit = plusmn 05 minutes of internal standard RT

Column used to flag values outside QC limits

FORM VIII 8260B

10162012Page 50 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014J1634-04-4 Methyl tert-butyl ether 017

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015J108-88-3 Toluene 017

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 51 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010J127-18-4 Tetrachloroethene 028

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

96 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 52 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 53 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08983d Report Date 12-Oct-2012 0041

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08983dLab Smp Id 460-45537-A-1 Client Smp ID WC-17338-100512-MW1Inj Date 11-OCT-2012 2341 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-1Misc Info 460-45537-A-1Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 8 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

28 MTBE 73 2016 2022 (0561) 2797 016909 017(a)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 375883 486598 49

52 Fluorobenzene 96 3595 3601 (1000) 1242225 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1240232 479413 48

66 Toluene 91 5162 5162 (0742) 4639 017041 017(a)

71 Tetrachloroethene 166 5582 5582 (0803) 1902 028047 028(a)

78 Chlorobenzene-d5 117 6954 6954 (1000) 1119807 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 516081 495668 50

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 641810 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 54 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

10162012Page 55 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

28 MTBE

10162012Page 56 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

66 Toluene

10162012Page 57 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

71 Tetrachloroethene

10162012Page 58 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014J1634-04-4 Methyl tert-butyl ether 020

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 59 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

98 70-130460-00-4 4-Bromofluorobenzene

97 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 60 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 61 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08984d Report Date 12-Oct-2012 1126

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08984dLab Smp Id 460-45537-A-2 Client Smp ID WC-17338-100512-MW1Inj Date 12-OCT-2012 0004 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-2Misc Info 460-45537-A-2Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 9 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

28 MTBE 73 2016 2022 (0561) 3378 020333 020(a)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 375158 483561 48

52 Fluorobenzene 96 3595 3601 (1000) 1247617 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1243750 487069 49

78 Chlorobenzene-d5 117 6954 6954 (1000) 1105330 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 506189 492299 49

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 633816 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 62 of 323

Data File e08984d

Date 12-OCT-2012 0004

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-2 Operator GCMS VOAMS5

10162012Page 63 of 323

Data File e08984d

Date 12-OCT-2012 0004

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-2 Operator GCMS VOAMS5

28 MTBE

10162012Page 64 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018J75-09-2 Methylene Chloride 074

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014U1634-04-4 Methyl tert-butyl ether 014

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080J67-66-3 Chloroform 0096

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 65 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

97 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 66 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 67 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08982d Report Date 12-Oct-2012 1126

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08982dLab Smp Id 460-45537-A-3 Client Smp ID TB-17338-100512-253Inj Date 11-OCT-2012 2317 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-3Misc Info 460-45537-A-3Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 7 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

22 Methylene Chloride 49 1864 1864 (0518) 6426 073512 074(a)

42 Chloroform 83 2839 2845 (0790) 973 009557 0096(aH)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 385354 484137 48

52 Fluorobenzene 96 3595 3601 (1000) 1280000 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1266759 482968 48

78 Chlorobenzene-d5 117 6954 6954 (1000) 1135339 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 518232 493851 49

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 646856 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

H - Operator selected an alternate compound hit

10162012Page 68 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

10162012Page 69 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

22 Methylene Chloride

10162012Page 70 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

42 Chloroform

10162012Page 71 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1280762 e07836d2Level IC 460-1280763 e07838d3Level ICIS 460-1280764 e07839d4Level IC 460-1280765 e07840d5Level IC 460-1280766 e07841d6Level IC 460-1280767 e07842d

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

Dichlorodifluoromethane 01877 01710 01761 01874 01774 Ave 6501572

01000 30001761

Chloromethane 04585 03624 03717 03896 03503 Ave 13403074

01000 30003733

Vinyl chloride 03440 02904 02965 03157 02914 Ave 10102532

01000 30002985

Bromomethane 01457 01433 01250 01279 01268 Ave 8301184

01000 30001312

Chloroethane 01177 01273 01133 01184 00992 Ave 14300838

01000 30001099

Trichlorofluoromethane 02861 02160 02403 02359 02461 Ave 9902285

01000 30002422

11-Dichloroethene 01607 01355 01549 01479 01528 Ave 5801456

01000 30001496

Carbon disulfide 07031 06470 06825 07347 07283 Ave 5906366

01000 30006887

112-Trichloro-122-trifluoroethane 01346 01631 01661 01849 01887 Ave 11601772

01000 30001691

Methylene Chloride 04479 03769 03581 03500 03182 Ave 14802947

01000 30003576

Acetone 00225 00193 00188 00182 00162 Ave 13800153

01000 30000184

trans-12-Dichloroethene 02047 01989 02141 02174 02016 Ave 4301946

01000 30002052

Methyl acetate 00482 00463 00420 00421 00402 Ave 9400371

01000 30000426

Methyl tert-butyl ether 07109 07281 06924 06817 06907 Ave 6505992

01000 30006838

11-Dichloroethane 04650 04524 04893 04673 04494 Ave 4604257

01000 30004582

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 72 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

cis-12-Dichloroethene 02536 02396 02453 02363 02237 Ave 5602184

01000 30002361

Cyclohexane 03116 04199 04030 04447 04640 Ave 13204438

01000 30004145

Chloroform 03895 04109 04030 04060 03948 Ave 2503851

01000 30003982

Carbon tetrachloride 02420 02373 02793 02813 02930 Ave 9102903

01000 30002705

111-Trichloroethane 03091 03114 03513 03424 03583 Ave 6403522

01000 30003375

2-Butanone (MEK) 00273 00279 00385 00372 00372 Ave 14900364

01000 30000341

Benzene 12012 12533 12592 12117 12284 Ave 8709836

01000 30011896

12-Dichloroethane 03398 03425 03293 03270 03193 Ave 3503124

01000 30003284

Methylcyclohexane 02272 03440 03287 03727 03690 Ave 16303532

01000 30003325

Trichloroethene 02571 02192 02414 02341 02365 Ave 5202426

01000 30002385

12-Dichloropropane 02758 02786 02804 02730 02724 Ave 1202733

01000 30002756

Dichlorobromomethane 03209 03160 03185 03141 03239 Ave 1303237

01000 30003195

cis-13-Dichloropropene 05043 05293 05370 05217 05393 Ave 3105530

01000 30005308

Toluene 13662 13454 14250 13844 13425 Ave 9510731

01000 30013228

Tetrachloroethene 02730 02844 03369 03253 03225 Ave 8303255

01000 30003113

4-Methyl-2-pentanone (MIBK) 03587 03603 03526 03550 03603 Ave 1603692

01000 30003593

trans-13-Dichloropropene 04563 04743 04806 04779 04910 Ave 3805114

01000 30004819

112-Trichloroethane 02303 02327 02287 02201 02185 Ave 2502280

01000 30002264

Chlorodibromomethane 03013 02986 03088 03052 03111 Ave 3003249

01000 30003083

12-Dibromoethane 02596 02708 02743 02671 02629 Ave 2002676

01000 30002670

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 73 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

2-Hexanone 02652 02737 02670 02679 02755 Ave 3202514

01000 30002668

Chlorobenzene 08958 08985 09292 09070 08727 Ave 4008261

01000 30008882

Ethylbenzene 04549 04523 04953 04866 04834 Ave 3704808

01000 30004756

m-Xylene amp p-Xylene 05967 05752 06297 06168 06094 Ave 6505224

01000 30005917

o-Xylene 05732 05675 06142 06014 05989 Ave 3205765

01000 30005886

Bromoform 02053 01991 02150 02194 02258 Ave 4902237

01000 30002147

Styrene 09657 09899 10525 10511 10477 Ave 6408917

01000 30009998

Isopropylbenzene 13314 13509 15606 15346 15340 Ave 10811764

01000 30014146

1122-Tetrachloroethane 06545 06405 06616 06489 06390 Ave 1706330

01000 30006462

13-Dichlorobenzene 12616 12687 13292 13133 12758 Ave 3012242

01000 30012788

14-Dichlorobenzene 13636 13114 13708 13534 13010 Ave 3412550

01000 30013259

12-Dichlorobenzene 12298 12143 12601 12232 11746 Ave 3211521

01000 30012090

12-Dibromo-3-Chloropropane 01290 01163 01082 01109 01042 Ave 7801095

01000 30001130

124-Trichlorobenzene 06538 06139 06311 06265 05725 Ave 5405732

01000 30006118

12-Dichloroethane-d4 (Surr) 02599 02736 02573 02553 02667 Ave 2802702

01000 30002638

Toluene-d8 (Surr) 11377 12027 11720 11573 11645 Ave 1811690

01000 30011672

4-Bromofluorobenzene 07799 08146 08086 08044 08193 Ave 1908206

01000 30008079

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 74 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1280762 e07836dLevel 2 IC 460-1280763 e07838dLevel 3 ICIS 460-1280764 e07839dLevel 4 IC 460-1280765 e07840dLevel 5 IC 460-1280766 e07841dLevel 6 IC 460-1280767 e07842d

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Dichlorodifluoromethane AveFB 8660 39416 167418 450014 17982634551928

100 500 200 500 200500

Chloromethane AveFB 21155 83523 353287 935453 35519068902969

100 500 200 500 200500

Vinyl chloride AveFB 15876 66919 281874 757876 29543837332518

100 500 200 500 200500

Bromomethane AveFB 6723 33032 118799 307121 12855673429373

100 500 200 500 200500

Chloroethane AveFB 5433 29332 107678 284219 10059762426216

100 500 200 500 200500

Trichlorofluoromethane AveFB 13203 49780 228376 566305 24953266618134

100 500 200 500 200500

11-Dichloroethene AveFB 7415 31234 147259 355088 15491024214942

100 500 200 500 200500

Carbon disulfide AveFB 32446 149121 648801 1763903 738404918433408

100 500 200 500 200500

112-Trichloro-122-trifluoroethane

AveFB 6213 37580 157867 443949 19130255130629

100 500 200 500 200500

Methylene Chloride AveFB 20667 86862 340378 840419 32256318533685

100 500 200 500 200500

Acetone AveFB 5188 13342 17849 43750 164598441742

500 150 200 500 200500

trans-12-Dichloroethene AveFB 9445 45844 203500 521911 20443355633771

100 500 200 500 200500

Methyl acetate AveFB 2222 10660 39926 101112 4077131074355

100 500 200 500 200500

Methyl tert-butyl ether AveFB 32806 167790 658123 1636664 700252217351574

100 500 200 500 200500

11-Dichloroethane AveFB 21457 104265 465144 1121930 455634112326764

100 500 200 500 200500

cis-12-Dichloroethene AveFB 11702 55218 233129 567238 22679686324299

100 500 200 500 200500

FORM VI 8260B 10162012Page 75 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Cyclohexane AveFB 14380 96765 383104 1067735 470410312852489

100 500 200 500 200500

Chloroform AveFB 17974 94697 383084 974788 400250611152231

100 500 200 500 200500

Carbon tetrachloride AveFB 11168 54679 265527 675330 29705928405131

100 500 200 500 200500

111-Trichloroethane AveFB 14264 71766 333961 821993 363312510199723

100 500 200 500 200500

2-Butanone (MEK) AveFB 6291 19260 36552 89217 3773171055008

500 150 200 500 200500

Benzene AveCBZ 45050 227079 968083 2380099 986355721876514

100 500 200 500 200500

12-Dichloroethane AveFB 15679 78926 312991 785178 32368389046377

100 500 200 500 200500

Methylcyclohexane AveFB 10486 79279 312424 894738 374094710227785

100 500 200 500 200500

Trichloroethene AveFB 11865 50527 229465 562086 23978387026524

100 500 200 500 200500

12-Dichloropropane AveFB 12728 64209 266559 655380 27621167913672

100 500 200 500 200500

Dichlorobromomethane AveFB 14807 72835 302742 754124 32836079374106

100 500 200 500 200500

cis-13-Dichloropropene AveCBZ 18914 95905 412847 1024782 433022112299317

100 500 200 500 200500

Toluene AveCBZ 51238 243768 1095520 2719268 1077972123868197

100 500 200 500 200500

Tetrachloroethene AveCBZ 10238 51530 258990 639002 25895417239654

100 500 200 500 200500

4-Methyl-2-pentanone (MIBK) AveCBZ 67258 195851 271059 697282 28927468212153

500 150 200 500 200500

trans-13-Dichloropropene AveCBZ 17115 85943 369516 938808 394242511373599

100 500 200 500 200500

112-Trichloroethane AveCBZ 8636 42154 175853 432262 17543015071317

100 500 200 500 200500

Chlorodibromomethane AveCBZ 11301 54107 237421 599464 24982697227226

100 500 200 500 200500

12-Dibromoethane AveCBZ 9735 49066 210900 524614 21107665952425

100 500 200 500 200500

2-Hexanone AveCBZ 49729 148758 205286 526223 22117155590902

500 150 200 500 200500

Chlorobenzene AveCBZ 33596 162793 714336 1781568 700752018374405

100 500 200 500 200500

FORM VI 8260B 10162012Page 76 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Ethylbenzene AveCBZ 17061 81955 380762 955894 388164310693410

100 500 200 500 200500

m-Xylene amp p-Xylene AveCBZ 44761 208423 968280 2423002 978688223238078

200 100 400 100 4001000

o-Xylene AveCBZ 21499 102832 472158 1181273 480921512821590

100 500 200 500 200500

Bromoform AveCBZ 7698 36074 165267 430943 18127954974461

100 500 200 500 200500

Styrene AveCBZ 36217 179367 809158 2064560 841264519831782

100 500 200 500 200500

Isopropylbenzene AveCBZ 49933 244766 1199765 3014281 1231710326165908

100 500 200 500 200500

1122-Tetrachloroethane AveDCB 13823 63947 277413 702309 28987687365342

100 500 200 500 200500

13-Dichlorobenzene AveDCB 26644 126663 557342 1421450 578731414243841

100 500 200 500 200500

14-Dichlorobenzene AveDCB 28798 130929 574816 1464915 590189114602396

100 500 200 500 200500

12-Dichlorobenzene AveDCB 25972 121236 528396 1324016 532862113405399

100 500 200 500 200500

12-Dibromo-3-Chloropropane AveDCB 2725 11615 45388 120062 4727441274610

100 500 200 500 200500

124-Trichlorobenzene AveDCB 13808 61295 264648 678119 25969596669727

100 500 200 500 200500

12-Dichloroethane-d4 (Surr) AveFB 599539 630441 611357 613057 676105782507

500 500 500 500 500500

Toluene-d8 (Surr) AveCBZ 2133452 2179204 2252606 2273339 23375152600040

500 500 500 500 500500

4-Bromofluorobenzene AveDCB 823604 813301 847619 870646 929176954872

500 500 500 500 500500

Curve Type LegendAve = Average ISTD

FORM VI 8260B 10162012Page 77 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07836d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07836dLab Smp Id IC-VMCAL1 Inj Date 17-SEP-2012 0449 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL1Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 2 Calibration Sample Level 1Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 8660 100000 11

3 Chloromethane 50 1004 1004 (0280) 21155 100000 12

4 Vinyl Chloride 62 1016 1016 (0283) 15876 100000 12

6 Bromomethane 94 1169 1169 (0326) 6723 100000 11

5 Chloroethane 64 1230 1230 (0343) 5433 100000 11

7 Trichlorofluoromethane 101 1291 1291 (0360) 13203 100000 12

14 Freon TF 101 1565 1565 (0436) 6213 100000 080(a)

15 11-Dichloroethene 96 1547 1547 (0431) 7415 100000 11

16 Acetone 58 1882 1882 (0524) 5188 500000 61

18 Carbon Disulfide 76 1559 1559 (0434) 32446 100000 10

27 Methyl Acetate 74 1955 1955 (0545) 2222 100000 11

22 Methylene Chloride 49 1851 1851 (0516) 20667 100000 12

28 MTBE 73 2016 2016 (0562) 32806 100000 10

25 trans-12-Dichloroethene 96 1937 1937 (0540) 9445 100000 100

30 11-Dichloroethane 63 2303 2303 (0642) 21457 100000 10

36 cis-12-Dichloroethene 96 2644 2644 (0737) 11702 100000 11

10162012Page 78 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07836d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0856) 6291 500000 40(a)

42 Chloroform 83 2839 2839 (0791) 17974 100000 098(a)

44 Cyclohexane 56 2778 2778 (0774) 14380 100000 075(a)

43 111-Trichloroethane 97 2973 2973 (0828) 14264 100000 092(a)

45 Carbon Tetrachloride 117 2924 2924 (0815) 11168 100000 089(a)

48 Benzene 78 3254 3254 (0468) 45050 100000 10

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 599539 500000 49

49 12-Dichloroethane 62 3412 3412 (0951) 15679 100000 10

52 Fluorobenzene 96 3589 3589 (1000) 2307227 500000

54 Trichloroethene 95 3735 3735 (1041) 11865 100000 11

56 Methyl cyclohexane 83 3723 3723 (1037) 10486 100000 068(a)

57 12-Dichloropropane 63 4192 4192 (1168) 12728 100000 10

68 Bromodichloromethane 83 4266 4266 (1189) 14807 100000 10

67 cis-13-Dichloropropene 75 4906 4906 (0706) 18914 100000 095(a)

70 4-Methyl-2-Pentanone 43 5625 5625 (0810) 67258 500000 50

$ 65 Toluene-d8 (SUR) 98 5101 5101 (0734) 2133452 500000 49

66 Toluene 91 5156 5156 (0742) 51238 100000 10

64 trans-13-Dichloropropene 75 5650 5650 (0813) 17115 100000 095(a)

69 112-Trichloroethane 83 5826 5826 (0839) 8636 100000 10

71 Tetrachloroethene 166 5582 5582 (0803) 10238 100000 088(a)

73 2-Hexanone 43 6674 6674 (0960) 49729 500000 50

74 Dibromochloromethane 129 6015 6015 (0866) 11301 100000 098(a)

77 12-Dibromoethane 107 6265 6265 (0902) 9735 100000 097(a)

78 Chlorobenzene-d5 117 6948 6948 (1000) 1875221 500000

79 Chlorobenzene 112 6972 6972 (1004) 33596 100000 10

81 Ethylbenzene 106 7064 7064 (1017) 17061 100000 096(a)

82 m+p-Xylene 106 7271 7271 (1046) 44761 200000 20

84 o-Xylene 106 7856 7856 (1131) 21499 100000 097(a)

85 Styrene 104 7942 7942 (1143) 36217 100000 096(a)

86 Bromoform 173 7911 7911 (1139) 7698 100000 096(a)

88 Isopropylbenzene 105 8344 8344 (1201) 49933 100000 094(a)

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 823604 500000 48

92 1122-Tetrachloroethane 83 9112 9112 (0871) 13823 100000 10

105 13-Dichlorobenzene 146 10332 10332 (0987) 26644 100000 099(a)

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1055978 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 28798 100000 10

111 12-Dichlorobenzene 146 11148 11148 (1065) 25972 100000 10(H)

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 2725 100000 11

114 124-Trichlorobenzene 180 12971 12971 (1239) 13808 100000 11

M 120 12-Dichloroethene (Total) 100 21147 200000 21

M 121 Xylene (Total) 100 66260 300000 30

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

H - Operator selected an alternate compound hit

10162012Page 79 of 323

Data File e07836d

Date 17-SEP-2012 0449

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL1 Operator GCMS VOAMS5

10162012Page 80 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07838d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07838dLab Smp Id IC-VMCAL2 Inj Date 17-SEP-2012 0536 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL2Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 4 Calibration Sample Level 2Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 39416 500000 48

3 Chloromethane 50 1016 1016 (0283) 83523 500000 48

4 Vinyl Chloride 62 1022 1022 (0285) 66919 500000 49

6 Bromomethane 94 1169 1169 (0326) 33032 500000 55

5 Chloroethane 64 1230 1230 (0343) 29332 500000 58

7 Trichlorofluoromethane 101 1291 1291 (0360) 49780 500000 45

14 Freon TF 101 1559 1559 (0434) 37580 500000 48

15 11-Dichloroethene 96 1541 1541 (0429) 31234 500000 45

16 Acetone 58 1894 1894 (0528) 13342 150000 16

18 Carbon Disulfide 76 1553 1553 (0433) 149121 500000 47

27 Methyl Acetate 74 1961 1961 (0546) 10660 500000 54

22 Methylene Chloride 49 1851 1851 (0516) 86862 500000 53

28 MTBE 73 2016 2016 (0562) 167790 500000 53

25 trans-12-Dichloroethene 96 1937 1937 (0540) 45844 500000 48

30 11-Dichloroethane 63 2296 2296 (0640) 104265 500000 49

36 cis-12-Dichloroethene 96 2644 2644 (0737) 55218 500000 51

10162012Page 81 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07838d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0857) 19260 150000 12

42 Chloroform 83 2839 2839 (0791) 94697 500000 52

44 Cyclohexane 56 2772 2772 (0772) 96765 500000 51

43 111-Trichloroethane 97 2973 2973 (0828) 71766 500000 46

45 Carbon Tetrachloride 117 2924 2924 (0815) 54679 500000 44

48 Benzene 78 3254 3254 (0468) 227079 500000 53

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 630441 500000 52

49 12-Dichloroethane 62 3412 3412 (0951) 78926 500000 52

52 Fluorobenzene 96 3589 3589 (1000) 2304638 500000

54 Trichloroethene 95 3735 3735 (1041) 50527 500000 46

56 Methyl cyclohexane 83 3717 3717 (1036) 79279 500000 52

57 12-Dichloropropane 63 4192 4192 (1168) 64209 500000 50

68 Bromodichloromethane 83 4272 4272 (1190) 72835 500000 49

67 cis-13-Dichloropropene 75 4906 4906 (0706) 95905 500000 50

70 4-Methyl-2-Pentanone 43 5625 5625 (0810) 195851 150000 15

$ 65 Toluene-d8 (SUR) 98 5101 5101 (0734) 2179204 500000 52

66 Toluene 91 5156 5156 (0742) 243768 500000 51

64 trans-13-Dichloropropene 75 5643 5643 (0812) 85943 500000 49

69 112-Trichloroethane 83 5820 5820 (0838) 42154 500000 51

71 Tetrachloroethene 166 5576 5576 (0803) 51530 500000 46

73 2-Hexanone 43 6680 6680 (0961) 148758 150000 15

74 Dibromochloromethane 129 6015 6015 (0866) 54107 500000 48

77 12-Dibromoethane 107 6259 6259 (0901) 49066 500000 51

78 Chlorobenzene-d5 117 6948 6948 (1000) 1811885 500000

79 Chlorobenzene 112 6972 6972 (1004) 162793 500000 50

81 Ethylbenzene 106 7058 7058 (1016) 81955 500000 48

82 m+p-Xylene 106 7271 7271 (1046) 208423 100000 97

84 o-Xylene 106 7856 7856 (1131) 102832 500000 48

85 Styrene 104 7942 7942 (1143) 179367 500000 50

86 Bromoform 173 7911 7911 (1139) 36074 500000 46

88 Isopropylbenzene 105 8344 8344 (1201) 244766 500000 48

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 813301 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 63947 500000 50

105 13-Dichlorobenzene 146 10325 10325 (0987) 126663 500000 50

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 998386 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 130929 500000 49

111 12-Dichlorobenzene 146 11148 11148 (1065) 121236 500000 50

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 11615 500000 51

114 124-Trichlorobenzene 180 12965 12965 (1239) 61295 500000 50

M 120 12-Dichloroethene (Total) 100 101062 100000 99

M 121 Xylene (Total) 100 311255 150000 14

10162012Page 82 of 323

Data File e07838d

Date 17-SEP-2012 0536

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL2 Operator GCMS VOAMS5

10162012Page 83 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07839d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07839dLab Smp Id ICIS-VMCAL3 Inj Date 17-SEP-2012 0600 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info ICIS-VMCAL3Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 5 Calibration Sample Level 3Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 167418 200000 20

3 Chloromethane 50 1016 1016 (0283) 353287 200000 20

4 Vinyl Chloride 62 1016 1016 (0283) 281874 200000 20

6 Bromomethane 94 1175 1175 (0327) 118799 200000 19

5 Chloroethane 64 1230 1230 (0343) 107678 200000 21

7 Trichlorofluoromethane 101 1291 1291 (0360) 228376 200000 20

14 Freon TF 101 1559 1559 (0434) 157867 200000 20

15 11-Dichloroethene 96 1540 1540 (0429) 147259 200000 21

16 Acetone 58 1888 1888 (0526) 17849 200000 20

18 Carbon Disulfide 76 1559 1559 (0434) 648801 200000 20

27 Methyl Acetate 74 1955 1955 (0545) 39926 200000 20

22 Methylene Chloride 49 1851 1851 (0516) 340378 200000 20

28 MTBE 73 2016 2016 (0562) 658123 200000 20

25 trans-12-Dichloroethene 96 1943 1943 (0541) 203500 200000 21

30 11-Dichloroethane 63 2303 2303 (0642) 465144 200000 21

36 cis-12-Dichloroethene 96 2644 2644 (0737) 233129 200000 21

10162012Page 84 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07839d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0856) 36552 200000 22

42 Chloroform 83 2839 2839 (0791) 383084 200000 20

44 Cyclohexane 56 2778 2778 (0774) 383104 200000 19

43 111-Trichloroethane 97 2973 2973 (0828) 333961 200000 21

45 Carbon Tetrachloride 117 2924 2924 (0815) 265527 200000 21

48 Benzene 78 3254 3254 (0468) 968083 200000 21

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 611357 500000 49

49 12-Dichloroethane 62 3412 3412 (0951) 312991 200000 20

52 Fluorobenzene 96 3589 3589 (1000) 2376396 500000

54 Trichloroethene 95 3735 3735 (1041) 229465 200000 20

56 Methyl cyclohexane 83 3723 3723 (1037) 312424 200000 20

57 12-Dichloropropane 63 4192 4192 (1168) 266559 200000 20

68 Bromodichloromethane 83 4266 4266 (1189) 302742 200000 20

67 cis-13-Dichloropropene 75 4906 4906 (0705) 412847 200000 20

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 271059 200000 20

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2252606 500000 50

66 Toluene 91 5156 5156 (0741) 1095520 200000 22

64 trans-13-Dichloropropene 75 5643 5643 (0812) 369516 200000 20

69 112-Trichloroethane 83 5820 5820 (0837) 175853 200000 20

71 Tetrachloroethene 166 5576 5576 (0802) 258990 200000 22

73 2-Hexanone 43 6680 6680 (0961) 205286 200000 20

74 Dibromochloromethane 129 6015 6015 (0865) 237421 200000 20

77 12-Dibromoethane 107 6259 6259 (0900) 210900 200000 20

78 Chlorobenzene-d5 117 6954 6954 (1000) 1921967 500000

79 Chlorobenzene 112 6972 6972 (1003) 714336 200000 21

81 Ethylbenzene 106 7064 7064 (1016) 380762 200000 21

82 m+p-Xylene 106 7277 7277 (1046) 968280 400000 42

84 o-Xylene 106 7856 7856 (1130) 472158 200000 21

85 Styrene 104 7942 7942 (1142) 809158 200000 21

86 Bromoform 173 7911 7911 (1138) 165267 200000 20

88 Isopropylbenzene 105 8344 8344 (1200) 1199765 200000 22

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 847619 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 277413 200000 20

105 13-Dichlorobenzene 146 10325 10325 (0987) 557342 200000 21

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1048295 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 574816 200000 21

111 12-Dichlorobenzene 146 11148 11148 (1065) 528396 200000 21

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 45388 200000 19

114 124-Trichlorobenzene 180 12965 12965 (1239) 264648 200000 21

M 120 12-Dichloroethene (Total) 100 436629 400000 42

M 121 Xylene (Total) 100 1440438 600000 63

10162012Page 85 of 323

Data File e07839d

Date 17-SEP-2012 0600

Client ID Instrument VOAMS5i

Sample Info ICIS-VMCAL3 Operator GCMS VOAMS5

10162012Page 86 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07840d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07840dLab Smp Id IC-VMCAL4 Inj Date 17-SEP-2012 0623 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL4Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 6 Calibration Sample Level 4Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 450014 500000 53

3 Chloromethane 50 1010 1010 (0281) 935453 500000 52

4 Vinyl Chloride 62 1016 1016 (0283) 757876 500000 53

6 Bromomethane 94 1175 1175 (0327) 307121 500000 49

5 Chloroethane 64 1230 1230 (0342) 284219 500000 54

7 Trichlorofluoromethane 101 1290 1290 (0359) 566305 500000 49

14 Freon TF 101 1565 1565 (0435) 443949 500000 55

15 11-Dichloroethene 96 1540 1540 (0428) 355088 500000 49

16 Acetone 58 1888 1888 (0525) 43750 500000 50

18 Carbon Disulfide 76 1559 1559 (0434) 1763903 500000 53

27 Methyl Acetate 74 1961 1961 (0546) 101112 500000 49

22 Methylene Chloride 49 1851 1851 (0515) 840419 500000 49

28 MTBE 73 2016 2016 (0561) 1636664 500000 50

25 trans-12-Dichloroethene 96 1943 1943 (0540) 521911 500000 53

30 11-Dichloroethane 63 2302 2302 (0640) 1121930 500000 51

36 cis-12-Dichloroethene 96 2644 2644 (0735) 567238 500000 50

10162012Page 87 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07840d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0854) 89217 500000 54

42 Chloroform 83 2839 2839 (0790) 974788 500000 51

44 Cyclohexane 56 2778 2778 (0773) 1067735 500000 54

43 111-Trichloroethane 97 2973 2973 (0827) 821993 500000 51

45 Carbon Tetrachloride 117 2924 2924 (0813) 675330 500000 52

48 Benzene 78 3254 3254 (0468) 2380099 500000 51

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0934) 613057 500000 48

49 12-Dichloroethane 62 3412 3412 (0949) 785178 500000 50

52 Fluorobenzene 96 3595 3595 (1000) 2400971 500000

54 Trichloroethene 95 3735 3735 (1039) 562086 500000 49

56 Methyl cyclohexane 83 3723 3723 (1036) 894738 500000 56

57 12-Dichloropropane 63 4192 4192 (1166) 655380 500000 50

68 Bromodichloromethane 83 4272 4272 (1188) 754124 500000 49

67 cis-13-Dichloropropene 75 4906 4906 (0705) 1024782 500000 49

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 697282 500000 49

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2273339 500000 50

66 Toluene 91 5162 5162 (0742) 2719268 500000 52

64 trans-13-Dichloropropene 75 5649 5649 (0812) 938808 500000 50

69 112-Trichloroethane 83 5820 5820 (0837) 432262 500000 49

71 Tetrachloroethene 166 5576 5576 (0802) 639002 500000 52

73 2-Hexanone 43 6680 6680 (0961) 526223 500000 50

74 Dibromochloromethane 129 6015 6015 (0865) 599464 500000 49

77 12-Dibromoethane 107 6259 6259 (0900) 524614 500000 50

78 Chlorobenzene-d5 117 6954 6954 (1000) 1964266 500000

79 Chlorobenzene 112 6972 6972 (1003) 1781568 500000 51

81 Ethylbenzene 106 7064 7064 (1016) 955894 500000 51

82 m+p-Xylene 106 7277 7277 (1046) 2423002 100000 100

84 o-Xylene 106 7862 7862 (1131) 1181273 500000 51

85 Styrene 104 7942 7942 (1142) 2064560 500000 52

86 Bromoform 173 7911 7911 (1138) 430943 500000 51

88 Isopropylbenzene 105 8350 8350 (1201) 3014281 500000 54

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 870646 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 702309 500000 50

105 13-Dichlorobenzene 146 10331 10331 (0987) 1421450 500000 51

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1082388 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 1464915 500000 51

111 12-Dichlorobenzene 146 11154 11154 (1066) 1324016 500000 50

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 120062 500000 49

114 124-Trichlorobenzene 180 12971 12971 (1239) 678119 500000 51

M 120 12-Dichloroethene (Total) 100 1089149 100000 100

M 121 Xylene (Total) 100 3604275 150000 160

10162012Page 88 of 323

Data File e07840d

Date 17-SEP-2012 0623

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL4 Operator GCMS VOAMS5

10162012Page 89 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07841d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07841dLab Smp Id IC-VMCAL5 Inj Date 17-SEP-2012 0646 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL5Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 7 Calibration Sample Level 5Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 1798263 200000 200

3 Chloromethane 50 1010 1010 (0281) 3551906 200000 190

4 Vinyl Chloride 62 1016 1016 (0283) 2954383 200000 200

6 Bromomethane 94 1175 1175 (0327) 1285567 200000 190

5 Chloroethane 64 1230 1230 (0342) 1005976 200000 180

7 Trichlorofluoromethane 101 1291 1291 (0359) 2495326 200000 200

14 Freon TF 101 1565 1565 (0435) 1913025 200000 220

15 11-Dichloroethene 96 1541 1541 (0429) 1549102 200000 200

16 Acetone 58 1894 1894 (0527) 164598 200000 180

18 Carbon Disulfide 76 1559 1559 (0434) 7384049 200000 210

27 Methyl Acetate 74 1961 1961 (0546) 407713 200000 190

22 Methylene Chloride 49 1851 1851 (0515) 3225631 200000 180

28 MTBE 73 2016 2016 (0561) 7002522 200000 200

25 trans-12-Dichloroethene 96 1943 1943 (0540) 2044335 200000 200

30 11-Dichloroethane 63 2303 2303 (0640) 4556341 200000 200

36 cis-12-Dichloroethene 96 2650 2650 (0737) 2267968 200000 190

10162012Page 90 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07841d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0854) 377317 200000 220

42 Chloroform 83 2839 2839 (0790) 4002506 200000 200

44 Cyclohexane 56 2784 2784 (0774) 4704103 200000 220

43 111-Trichloroethane 97 2979 2979 (0829) 3633125 200000 210

45 Carbon Tetrachloride 117 2930 2930 (0815) 2970592 200000 220

48 Benzene 78 3260 3260 (0468) 9863557 200000 210

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 676105 500000 50

49 12-Dichloroethane 62 3418 3418 (0951) 3236838 200000 190

52 Fluorobenzene 96 3595 3595 (1000) 2534623 500000

54 Trichloroethene 95 3741 3741 (1041) 2397838 200000 200

56 Methyl cyclohexane 83 3729 3729 (1037) 3740947 200000 220

57 12-Dichloropropane 63 4199 4199 (1168) 2762116 200000 200

68 Bromodichloromethane 83 4272 4272 (1188) 3283607 200000 200

67 cis-13-Dichloropropene 75 4912 4912 (0706) 4330221 200000 200

70 4-Methyl-2-Pentanone 43 5631 5631 (0809) 2892746 200000 200

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2337515 500000 50

66 Toluene 91 5162 5162 (0742) 10779721 200000 200

64 trans-13-Dichloropropene 75 5656 5656 (0813) 3942425 200000 200

69 112-Trichloroethane 83 5826 5826 (0837) 1754301 200000 190

71 Tetrachloroethene 166 5582 5582 (0802) 2589541 200000 210

73 2-Hexanone 43 6686 6686 (0961) 2211715 200000 210

74 Dibromochloromethane 129 6021 6021 (0865) 2498269 200000 200

77 12-Dibromoethane 107 6265 6265 (0900) 2110766 200000 200

78 Chlorobenzene-d5 117 6960 6960 (1000) 2007362 500000

79 Chlorobenzene 112 6978 6978 (1003) 7007520 200000 200

81 Ethylbenzene 106 7076 7076 (1017) 3881643 200000 200

82 m+p-Xylene 106 7289 7289 (1047) 9786882 400000 410

84 o-Xylene 106 7869 7869 (1131) 4809215 200000 200

85 Styrene 104 7954 7954 (1143) 8412645 200000 210

86 Bromoform 173 7923 7923 (1138) 1812795 200000 210

88 Isopropylbenzene 105 8356 8356 (1201) 12317103 200000 220(A)

$ 89 Bromofluorobenzene (SUR) 174 8716 8716 (0832) 929176 500000 51

92 1122-Tetrachloroethane 83 9124 9124 (0871) 2898768 200000 200

105 13-Dichlorobenzene 146 10344 10344 (0987) 5787314 200000 200

108 14-Dichlorobenzene-d4 152 10478 10478 (1000) 1134091 500000

109 14-Dichlorobenzene 146 10502 10502 (1002) 5901891 200000 200

111 12-Dichlorobenzene 146 11167 11167 (1066) 5328621 200000 190

112 12-Dibromo-3-chloropropane 75 12240 12240 (1168) 472744 200000 180

114 124-Trichlorobenzene 180 12971 12971 (1238) 2596959 200000 190

M 120 12-Dichloroethene (Total) 100 4312303 400000 380

M 121 Xylene (Total) 100 14596097 600000 620

QC Flag Legend

A - Target compound detected but quantitated amountexceeded maximum amount

10162012Page 91 of 323

Data File e07841d

Date 17-SEP-2012 0646

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL5 Operator GCMS VOAMS5

10162012Page 92 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07842d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07842dLab Smp Id IC-VMCAL6 Inj Date 17-SEP-2012 0710 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL6Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 8 Calibration Sample Level 6Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 4551928 500000 450

3 Chloromethane 50 1010 1010 (0280) 8902969 500000 410

4 Vinyl Chloride 62 1016 1016 (0282) 7332518 500000 420

6 Bromomethane 94 1175 1175 (0326) 3429373 500000 450

5 Chloroethane 64 1230 1230 (0341) 2426216 500000 380

7 Trichlorofluoromethane 101 1297 1297 (0360) 6618134 500000 470

14 Freon TF 101 1571 1571 (0436) 5130629 500000 520(A)

15 11-Dichloroethene 96 1547 1547 (0429) 4214942 500000 490

16 Acetone 58 1894 1894 (0526) 441742 500000 420

18 Carbon Disulfide 76 1559 1559 (0433) 18433408 500000 460

27 Methyl Acetate 74 1961 1961 (0545) 1074355 500000 440

22 Methylene Chloride 49 1851 1851 (0514) 8533685 500000 410

28 MTBE 73 2022 2022 (0562) 17351574 500000 440

25 trans-12-Dichloroethene 96 1943 1943 (0540) 5633771 500000 470

30 11-Dichloroethane 63 2302 2302 (0639) 12326764 500000 460

36 cis-12-Dichloroethene 96 2650 2650 (0736) 6324299 500000 460

10162012Page 93 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07842d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3083 3083 (0856) 1055008 500000 530(A)

42 Chloroform 83 2845 2845 (0790) 11152231 500000 480

44 Cyclohexane 56 2790 2790 (0775) 12852489 500000 540(A)

43 111-Trichloroethane 97 2985 2985 (0829) 10199723 500000 520(A)

45 Carbon Tetrachloride 117 2936 2936 (0815) 8405131 500000 540(A)

48 Benzene 78 3260 3260 (0468) 21876514 500000 410

$ 47 12-Dichloroethane-d4 (SUR) 65 3369 3369 (0936) 782507 500000 51

49 12-Dichloroethane 62 3424 3424 (0951) 9046377 500000 480

52 Fluorobenzene 96 3601 3601 (1000) 2895790 500000

54 Trichloroethene 95 3753 3753 (1042) 7026524 500000 510(A)

56 Methyl cyclohexane 83 3741 3741 (1039) 10227785 500000 530(A)

57 12-Dichloropropane 63 4205 4205 (1168) 7913672 500000 500

68 Bromodichloromethane 83 4284 4284 (1190) 9374106 500000 510(A)

67 cis-13-Dichloropropene 75 4924 4924 (0706) 12299317 500000 520(A)

70 4-Methyl-2-Pentanone 43 5649 5649 (0810) 8212153 500000 510(A)

$ 65 Toluene-d8 (SUR) 98 5113 5113 (0733) 2600040 500000 50

66 Toluene 91 5168 5168 (0741) 23868197 500000 400

64 trans-13-Dichloropropene 75 5668 5668 (0813) 11373599 500000 530(A)

69 112-Trichloroethane 83 5838 5838 (0837) 5071317 500000 500(A)

71 Tetrachloroethene 166 5594 5594 (0802) 7239654 500000 520(A)

73 2-Hexanone 43 6698 6698 (0961) 5590902 500000 470

74 Dibromochloromethane 129 6033 6033 (0865) 7227226 500000 530(A)

77 12-Dibromoethane 107 6277 6277 (0900) 5952425 500000 500(A)

78 Chlorobenzene-d5 117 6972 6972 (1000) 2224153 500000

79 Chlorobenzene 112 6997 6997 (1003) 18374405 500000 460

81 Ethylbenzene 106 7094 7094 (1017) 10693410 500000 500(A)

82 m+p-Xylene 106 7308 7308 (1048) 23238078 100000 880

84 o-Xylene 106 7887 7887 (1131) 12821590 500000 490

85 Styrene 104 7966 7966 (1143) 19831782 500000 440

86 Bromoform 173 7942 7942 (1139) 4974461 500000 520(A)

88 Isopropylbenzene 105 8368 8368 (1200) 26165908 500000 420(A)

$ 89 Bromofluorobenzene (SUR) 174 8728 8728 (0832) 954872 500000 51

92 1122-Tetrachloroethane 83 9143 9143 (0871) 7365342 500000 490

105 13-Dichlorobenzene 146 10362 10362 (0987) 14243841 500000 480

108 14-Dichlorobenzene-d4 152 10496 10496 (1000) 1163568 500000

109 14-Dichlorobenzene 146 10526 10526 (1003) 14602396 500000 470

111 12-Dichlorobenzene 146 11185 11185 (1066) 13405399 500000 480

112 12-Dibromo-3-chloropropane 75 12246 12246 (1167) 1274610 500000 480

114 124-Trichlorobenzene 180 12977 12977 (1236) 6669727 500000 470

M 120 12-Dichloroethene (Total) 100 11958070 100000 940

M 121 Xylene (Total) 100 36059668 150000 1400

QC Flag Legend

A - Target compound detected but quantitated amountexceeded maximum amount

10162012Page 94 of 323

Data File e07842d

Date 17-SEP-2012 0710

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL6 Operator GCMS VOAMS5

10162012Page 95 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10112012 2050

09172012 0449

09172012 0710

CCVIS 460-1316562

Rtx-VMS

TestAmerica Edison

Lab File ID e08976d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Dichlorodifluoromethane 0194701761 01000 221 200 105 250Ave

Chloromethane 0322303733 01000 173 200 -137 250Ave

Vinyl chloride 0274402985 01000 184 200 -81 250Ave

Bromomethane 0159401312 01000 243 200 215 250Ave

Chloroethane 0127501099 01000 232 200 160 250Ave

Trichlorofluoromethane 0296002422 01000 244 200 222 250Ave

11-Dichloroethene 0161001496 01000 215 200 76 250Ave

Carbon disulfide 0655806887 01000 190 200 -48 250Ave

112-Trichloro-122-trifluoroethane

0198901691 01000 235 200 176 250Ave

Methylene Chloride 0341503576 01000 191 200 -45 250Ave

Acetone 0021400184 01000 233 200 164 250Ave

trans-12-Dichloroethene 0208902052 01000 204 200 18 250Ave

Methyl acetate 0037700426 01000 177 200 -115 250Ave

Methyl tert-butyl ether 0665806838 01000 195 200 -26 250Ave

11-Dichloroethane 0443404582 01000 194 200 -32 250Ave

cis-12-Dichloroethene 0227602361 01000 193 200 -36 250Ave

Cyclohexane 0338904145 01000 163 200 -183 250Ave

Chloroform 0397703982 01000 200 200 -01 250Ave

Carbon tetrachloride 0281602705 01000 208 200 41 250Ave

111-Trichloroethane 0352303375 01000 209 200 44 250Ave

2-Butanone (MEK) 0035400341 01000 208 200 40 250Ave

Benzene 10301190 01000 173 200 -134 250Ave

12-Dichloroethane 0331603284 01000 202 200 10 250Ave

Methylcyclohexane 0280603325 01000 169 200 -156 250Ave

Trichloroethene 0228602385 01000 192 200 -41 250Ave

12-Dichloropropane 0242002756 01000 176 200 -122 250Ave

Dichlorobromomethane 0303603195 01000 190 200 -50 250Ave

cis-13-Dichloropropene 0438605308 01000 165 200 -174 250Ave

Toluene 12151323 01000 184 200 -81 250Ave

Tetrachloroethene 0302803113 01000 195 200 -27 250Ave

4-Methyl-2-pentanone (MIBK) 0273203593 01000 152 200 -240 250Ave

trans-13-Dichloropropene 0396604819 01000 165 200 -177 250Ave

112-Trichloroethane 0185102264 01000 164 200 -182 250Ave

Chlorodibromomethane 0265003083 01000 172 200 -141 250Ave

12-Dibromoethane 0231002670 01000 173 200 -135 250Ave

2-Hexanone 0209702668 01000 157 200 -214 250Ave

Chlorobenzene 0830208882 01000 187 200 -65 250Ave

Ethylbenzene 0437104756 01000 184 200 -81 250Ave

m-Xylene amp p-Xylene 0555805917 01000 376 400 -61 250Ave

o-Xylene 0545405886 01000 185 200 -73 250Ave

FORM VII 8260B

10162012Page 96 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10112012 2050

09172012 0449

09172012 0710

CCVIS 460-1316562

Rtx-VMS

TestAmerica Edison

Lab File ID e08976d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Bromoform 0188102147 01000 175 200 -124 250Ave

Styrene 092181000 01000 184 200 -78 250Ave

Isopropylbenzene 13421415 01000 190 200 -52 250Ave

1122-Tetrachloroethane 0512306462 01000 159 200 -207 250Ave

13-Dichlorobenzene 11861279 01000 186 200 -72 250Ave

14-Dichlorobenzene 12311326 01000 186 200 -72 250Ave

12-Dichlorobenzene 11211209 01000 185 200 -73 250Ave

12-Dibromo-3-Chloropropane 0086101130 01000 152 200 -238 250Ave

124-Trichlorobenzene 0630306118 01000 206 200 30 250Ave

12-Dichloroethane-d4 (Surr) 0310902638 01000 589 500 178 250Ave

Toluene-d8 (Surr) 11551167 01000 495 500 -11 250Ave

4-Bromofluorobenzene 0811108079 01000 502 500 04 250Ave

FORM VII 8260B

10162012Page 97 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08976d Report Date 11-Oct-2012 2130

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08976dLab Smp Id CCVIS Inj Date 11-OCT-2012 2050 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info CCVISMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 1 Continuing Calibration SampleDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0900 0900 (0250) 102235 200000 22

3 Chloromethane 50 1016 1016 (0282) 169224 200000 17

4 Vinyl Chloride 62 1028 1028 (0286) 144069 200000 18

6 Bromomethane 94 1181 1181 (0328) 83687 200000 24

5 Chloroethane 64 1242 1242 (0345) 66969 200000 23

7 Trichlorofluoromethane 101 1303 1303 (0362) 155393 200000 24

14 Freon TF 101 1577 1577 (0438) 104446 200000 24

15 11-Dichloroethene 96 1553 1553 (0431) 84531 200000 22

16 Acetone 58 1894 1894 (0526) 11228 200000 23

18 Carbon Disulfide 76 1571 1571 (0436) 344348 200000 19

27 Methyl Acetate 74 1967 1967 (0546) 19813 200000 18

22 Methylene Chloride 49 1864 1864 (0518) 179288 200000 19

28 MTBE 73 2022 2022 (0562) 349596 200000 19

25 trans-12-Dichloroethene 96 1949 1949 (0541) 109681 200000 20

30 11-Dichloroethane 63 2309 2309 (0641) 232818 200000 19

36 cis-12-Dichloroethene 96 2656 2656 (0738) 119502 200000 19

10162012Page 98 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08976d Report Date 11-Oct-2012 2130

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0854) 18598 200000 21

42 Chloroform 83 2845 2845 (0790) 208815 200000 20

44 Cyclohexane 56 2784 2784 (0773) 177923 200000 16

43 111-Trichloroethane 97 2985 2985 (0829) 185002 200000 21

45 Carbon Tetrachloride 117 2937 2937 (0815) 147853 200000 21

48 Benzene 78 3260 3260 (0469) 476925 200000 17

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0934) 408134 500000 59

49 12-Dichloroethane 62 3418 3418 (0949) 174132 200000 20

52 Fluorobenzene 96 3601 3601 (1000) 1312656 500000

54 Trichloroethene 95 3741 3741 (1039) 120041 200000 19

56 Methyl cyclohexane 83 3729 3729 (1036) 147336 200000 17

57 12-Dichloropropane 63 4199 4199 (1166) 127078 200000 18

68 Bromodichloromethane 83 4272 4272 (1186) 159386 200000 19

67 cis-13-Dichloropropene 75 4912 4912 (0706) 203059 200000 16

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 126467 200000 15

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1336847 500000 49

66 Toluene 91 5162 5162 (0742) 562689 200000 18

64 trans-13-Dichloropropene 75 5649 5649 (0812) 183587 200000 16

69 112-Trichloroethane 83 5820 5820 (0837) 85707 200000 16

71 Tetrachloroethene 166 5582 5582 (0803) 140177 200000 19

73 2-Hexanone 43 6680 6680 (0961) 97080 200000 16

74 Dibromochloromethane 129 6021 6021 (0866) 122657 200000 17

77 12-Dibromoethane 107 6265 6265 (0901) 106920 200000 17

78 Chlorobenzene-d5 117 6954 6954 (1000) 1157341 500000

79 Chlorobenzene 112 6972 6972 (1003) 384334 200000 19

81 Ethylbenzene 106 7064 7064 (1016) 202362 200000 18

82 m+p-Xylene 106 7277 7277 (1046) 514606 400000 38

84 o-Xylene 106 7862 7862 (1131) 252476 200000 18

85 Styrene 104 7942 7942 (1142) 426740 200000 18

86 Bromoform 173 7911 7911 (1138) 87078 200000 18

88 Isopropylbenzene 105 8350 8350 (1201) 621124 200000 19

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 541700 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 136860 200000 16

105 13-Dichlorobenzene 146 10331 10331 (0987) 316835 200000 18

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 667834 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 328709 200000 18

111 12-Dichlorobenzene 146 11148 11148 (1065) 299393 200000 18

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 23001 200000 15

114 124-Trichlorobenzene 180 12977 12977 (1240) 168371 200000 21

M 120 12-Dichloroethene (Total) 100 229183 400000 40

M 121 Xylene (Total) 100 767082 600000 56

10162012Page 99 of 323

Data File e08976d

Date 11-OCT-2012 2050

Client ID Instrument VOAMS5i

Sample Info CCVIS Operator GCMS VOAMS5

10162012Page 100 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10122012 0114

09172012 0449

09172012 0710

CCV 460-13165610

Rtx-VMS

TestAmerica Edison

Lab File ID e08987d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Dichlorodifluoromethane 0166601761 01000 189 200 -54 250Ave

Chloromethane 0311403733 01000 167 200 -166 250Ave

Vinyl chloride 0256002985 01000 172 200 -142 250Ave

Bromomethane 0162301312 01000 247 200 237 250Ave

Chloroethane 0127201099 01000 231 200 157 250Ave

Trichlorofluoromethane 0257102422 01000 212 200 62 250Ave

11-Dichloroethene 0184901496 01000 247 200 236 250Ave

112-Trichloro-122-trifluoroethane

0225501691 01000 267 200 334 250Ave

Carbon disulfide 0788506887 01000 229 200 145 250Ave

Methylene Chloride 0351303576 01000 196 200 -18 250Ave

Acetone 0022000184 01000 239 200 197 250Ave

trans-12-Dichloroethene 0232002052 01000 226 200 130 250Ave

Methyl acetate 0048700426 01000 228 200 141 250Ave

Methyl tert-butyl ether 0769506838 01000 225 200 125 250Ave

11-Dichloroethane 0469804582 01000 205 200 25 250Ave

cis-12-Dichloroethene 0240902361 01000 204 200 20 250Ave

Cyclohexane 0384004145 01000 185 200 -74 250Ave

Chloroform 0438203982 01000 220 200 100 250Ave

Carbon tetrachloride 0291802705 01000 216 200 79 250Ave

111-Trichloroethane 0362803375 01000 215 200 75 250Ave

2-Butanone (MEK) 0042500341 01000 250 200 248 250Ave

Benzene 11151190 01000 188 200 -62 250Ave

12-Dichloroethane 0359603284 01000 219 200 95 250Ave

Methylcyclohexane 0344803325 01000 207 200 37 250Ave

Trichloroethene 0248302385 01000 208 200 41 250Ave

12-Dichloropropane 0265202756 01000 192 200 -38 250Ave

Dichlorobromomethane 0339803195 01000 213 200 63 250Ave

cis-13-Dichloropropene 0490405308 01000 185 200 -76 250Ave

Toluene 12801323 01000 194 200 -32 250Ave

Tetrachloroethene 0323103113 01000 208 200 38 250Ave

4-Methyl-2-pentanone (MIBK) 0319703593 01000 178 200 -110 250Ave

trans-13-Dichloropropene 0454104819 01000 188 200 -58 250Ave

112-Trichloroethane 0212502264 01000 188 200 -61 250Ave

Chlorodibromomethane 0306403083 01000 199 200 -06 250Ave

12-Dibromoethane 0261302670 01000 196 200 -22 250Ave

2-Hexanone 0243802668 01000 183 200 -86 250Ave

Chlorobenzene 0879308882 01000 198 200 -10 250Ave

Ethylbenzene 0463104756 01000 195 200 -26 250Ave

m-Xylene amp p-Xylene 0587505917 01000 397 400 -07 250Ave

o-Xylene 0578505886 01000 197 200 -17 250Ave

FORM VII 8260B

10162012Page 101 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10122012 0114

09172012 0449

09172012 0710

CCV 460-13165610

Rtx-VMS

TestAmerica Edison

Lab File ID e08987d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Bromoform 0223102147 01000 208 200 39 250Ave

Styrene 099051000 01000 198 200 -09 250Ave

Isopropylbenzene 14391415 01000 203 200 17 250Ave

1122-Tetrachloroethane 0579606462 01000 179 200 -103 250Ave

13-Dichlorobenzene 12591279 01000 197 200 -15 250Ave

14-Dichlorobenzene 13061326 01000 197 200 -15 250Ave

12-Dichlorobenzene 12151209 01000 201 200 05 250Ave

12-Dibromo-3-Chloropropane 0102901130 01000 182 200 -90 250Ave

124-Trichlorobenzene 0743906118 01000 243 200 216 250Ave

12-Dichloroethane-d4 (Surr) 0320902638 01000 608 500 216 250Ave

Toluene-d8 (Surr) 11471167 01000 491 500 -18 250Ave

4-Bromofluorobenzene 0806308079 01000 499 500 -02 250Ave

FORM VII 8260B

10162012Page 102 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12abe08987d Report Date 12-Oct-2012 0132

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12abe08987dLab Smp Id CCV Inj Date 12-OCT-2012 0114 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info CCVMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12ab8260DE_09mMeth Date 12-Oct-2012 0132 ken Quant Type ISTDCal Date 12-OCT-2012 0114 Cal File e08987dAls bottle 12 Continuing Calibration SampleDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0894 (0249) 84911 200000 19

3 Chloromethane 50 1016 1016 (0283) 158694 200000 17

4 Vinyl Chloride 62 1022 1022 (0284) 130464 200000 17

6 Bromomethane 94 1181 1181 (0328) 82695 200000 25

5 Chloroethane 64 1236 1236 (0344) 64840 200000 23

7 Trichlorofluoromethane 101 1297 1297 (0361) 131020 200000 21

14 Freon TF 101 1565 1565 (0435) 114931 200000 27

15 11-Dichloroethene 96 1547 1547 (0430) 94244 200000 25

16 Acetone 58 1894 1894 (0527) 11208 200000 24

18 Carbon Disulfide 76 1565 1565 (0435) 401807 200000 23

27 Methyl Acetate 74 1961 1961 (0546) 24794 200000 23

22 Methylene Chloride 49 1857 1857 (0517) 179010 200000 20

28 MTBE 73 2022 2022 (0562) 392131 200000 22

25 trans-12-Dichloroethene 96 1943 1943 (0540) 118223 200000 23

30 11-Dichloroethane 63 2302 2302 (0640) 239419 200000 20

36 cis-12-Dichloroethene 96 2650 2650 (0737) 122782 200000 20

10162012Page 103 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12abe08987d Report Date 12-Oct-2012 0132

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0856) 21666 200000 25

42 Chloroform 83 2845 2845 (0791) 223324 200000 22

44 Cyclohexane 56 2784 2784 (0774) 195679 200000 18

43 111-Trichloroethane 97 2979 2979 (0829) 184861 200000 21

45 Carbon Tetrachloride 117 2930 2930 (0815) 148689 200000 22

48 Benzene 78 3260 3260 (0469) 501947 200000 19

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 408924 500000 61

49 12-Dichloroethane 62 3418 3418 (0951) 183231 200000 22

52 Fluorobenzene 96 3595 3595 (1000) 1274024 500000

54 Trichloroethene 95 3741 3741 (1041) 126518 200000 21

56 Methyl cyclohexane 83 3723 3723 (1036) 175700 200000 21

57 12-Dichloropropane 63 4192 4192 (1166) 135130 200000 19

68 Bromodichloromethane 83 4272 4272 (1188) 173147 200000 21

67 cis-13-Dichloropropene 75 4906 4906 (0705) 220680 200000 18

70 4-Methyl-2-Pentanone 43 5631 5631 (0810) 143892 200000 18

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1290179 500000 49

66 Toluene 91 5162 5162 (0742) 576151 200000 19

64 trans-13-Dichloropropene 75 5649 5649 (0812) 204342 200000 19

69 112-Trichloroethane 83 5820 5820 (0837) 95620 200000 19

71 Tetrachloroethene 166 5582 5582 (0803) 145404 200000 21

73 2-Hexanone 43 6680 6680 (0961) 109697 200000 18

74 Dibromochloromethane 129 6015 6015 (0865) 137888 200000 20

77 12-Dibromoethane 107 6265 6265 (0901) 117575 200000 20

78 Chlorobenzene-d5 117 6954 6954 (1000) 1125053 500000

79 Chlorobenzene 112 6972 6972 (1003) 395719 200000 20

81 Ethylbenzene 106 7064 7064 (1016) 208414 200000 19

82 m+p-Xylene 106 7277 7277 (1046) 528781 400000 40

84 o-Xylene 106 7856 7856 (1130) 260320 200000 20

85 Styrene 104 7942 7942 (1142) 445737 200000 20

86 Bromoform 173 7917 7917 (1139) 100375 200000 21

88 Isopropylbenzene 105 8344 8344 (1200) 647568 200000 20

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 536325 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 154190 200000 18

105 13-Dichlorobenzene 146 10331 10331 (0987) 335032 200000 20

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 665092 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 347387 200000 20

111 12-Dichlorobenzene 146 11148 11148 (1065) 323155 200000 20

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 27376 200000 18

114 124-Trichlorobenzene 180 12977 12977 (1240) 197894 200000 24

M 120 12-Dichloroethene (Total) 100 241005 400000 43

M 121 Xylene (Total) 100 789101 600000 59

10162012Page 104 of 323

Data File e08987d

Date 12-OCT-2012 0114

Client ID Instrument VOAMS5i

Sample Info CCV Operator GCMS VOAMS5

10162012Page 105 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07834d Report Date 17-Sep-2012 0605

TestAmerica

Data file chemVOAMS5i8260DE09-17-1217sep12be07834dLab Smp Id BFB Inj Date 17-SEP-2012 0324 Operator VOAMS 1 Inst ID VOAMS5iSmp Info BFBMisc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12bBFBDELmMeth Date 27-Feb-2012 1508 sylvanus Quant Type ISTDCal Date Cal File Als bottle 2 QC Sample BFBDil Factor 100000 Integrator HP RTE Compound Sublist allsubTarget Version 350 Sample Matrix WATERProcessing Host hpd2

Concentration Formula Amt DF Uf Vf VI CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorUf 100000 ng unit correction factorVf 100000 Volumetric correction factorVI 100000 Injection Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT (REL RT) MASS RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ==== ======== ======= ======= ============ =====

1 BFB CAS 460-00-4

2352 2600 (0000) 95 195072 000- 10000 10000

2352 2600 (0000) 50 42624 1500- 4000 2185

2352 2600 (0000) 75 102376 3000- 6000 5248

2352 2600 (0000) 96 12530 500- 900 642

2352 2600 (0000) 173 0 000- 200 000

2352 2600 (0000) 174 155200 5000- 10000 7956

2352 2600 (0000) 175 12902 500- 900 831

2352 2600 (0000) 176 148480 9500- 10100 9567

2352 2600 (0000) 177 9343 500- 900 629

-------------------------------------------------------------------------------

10162012Page 106 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

10162012Page 107 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

1 BFB

RELATIVE me ION ABUNDANCE CRITERIA ABUNDANCE

+-----+------------------------------------------+---------------------+| | | || 95 | Base Peak 100 relative abundance | 10000 || 50 | 1500 - 4000 of mass 95 | 2185 || 75 | 3000 - 6000 of mass 95 | 5248 || 96 | 500 - 900 of mass 95 | 642 || 173 | Less than 200 of mass 174 | 000 ( 000) || 174 | 5000 - 10000 of mass 95 | 7956 || 175 | 500 - 900 of mass 174 | 661 ( 831) || 176 | 9500 - 10100 of mass 174 | 7612 ( 9567) || 177 | 500 - 900 of mass 176 | 479 ( 629) |+-----+------------------------------------------+---------------------+

10162012Page 108 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

Data File chemVOAMS5i8260DE09-17-1217sep12be07834dSpectrum Avg Scans 50-52 ( 235) Background Scan 46

Location of Maximum 9500Number of points 151

mz Y mz Y mz Y mz Y+------------------+------------------+------------------+------------------+| 3500 53 | 7700 1350 | 12300 88 | 17700 9343 || 3600 1914 | 7800 695 | 12400 252 | 17800 381 || 3700 12535 | 7900 5782 | 12500 148 | 18000 35 || 3800 10760 | 8000 1455 | 12700 282 | 18300 181 || 3900 3962 | 8100 5745 | 12800 338 | 18600 248 |+------------------+------------------+------------------+------------------+| 4100 387 | 8200 905 | 12900 75 | 18700 80 || 4400 707 | 8300 42 | 13000 926 | 18800 162 || 4500 1464 | 8500 229 | 13100 166 | 18900 142 || 4600 281 | 8600 239 | 13200 7 | 19100 151 || 4700 3334 | 8700 7427 | 13400 27 | 19200 54 |+------------------+------------------+------------------+------------------+| 4800 1491 | 8800 7774 | 13700 332 | 19300 44 || 4900 8401 | 9100 1022 | 13800 172 | 19400 110 || 5000 42624 | 9200 5845 | 14000 185 | 19600 46 || 5100 13346 | 9300 8046 | 14100 1957 | 19800 171 || 5200 539 | 9400 21672 | 14200 53 | 20000 162 |+------------------+------------------+------------------+------------------+| 5300 13 | 9500 195072 | 14300 1698 | 20200 62 || 5400 14 | 9600 12530 | 14400 295 | 20300 48 || 5500 230 | 9700 551 | 14500 186 | 20400 104 || 5600 3600 | 9900 79 | 14600 115 | 20500 34 || 5700 5500 | 10000 36 | 14700 156 | 20700 223 |+------------------+------------------+------------------+------------------+| 5800 113 | 10100 136 | 14800 465 | 20900 81 || 5900 106 | 10200 36 | 14900 118 | 21500 80 || 6000 1861 | 10300 237 | 15000 105 | 21900 89 || 6100 10125 | 10400 905 | 15300 459 | 22000 60 || 6200 9219 | 10500 514 | 15400 192 | 22600 84 |+------------------+------------------+------------------+------------------+| 6300 7541 | 10600 1054 | 15700 390 | 23000 188 || 6400 270 | 10700 304 | 16000 378 | 23100 74 || 6500 625 | 11000 398 | 16100 530 | 23500 107 || 6600 51 | 11100 151 | 16400 54 | 23900 43 || 6700 378 | 11200 121 | 16700 172 | 24600 123 |+------------------+------------------+------------------+------------------+| 6800 20496 | 11300 247 | 16800 205 | 24700 37 || 6900 19976 | 11500 421 | 16900 243 | 25000 57 || 7000 1570 | 11600 358 | 17000 351 | 25200 33 || 7200 740 | 11700 1343 | 17100 439 | 25500 46 || 7300 9006 | 11800 855 | 17200 227 | 26200 43 |+------------------+------------------+------------------+------------------+| 7400 34320 | 11900 733 | 17400 155200 | 26400 63 || 7500 102376 | 12100 68 | 17500 12902 | 26500 45 || 7600 8204 | 12200 77 | 17600 148480 | |+------------------+------------------+------------------+------------------+

10162012Page 109 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08975d Report Date 11-Oct-2012 2012

TestAmerica

Data file chemVOAMS5i8260DE09-17-1211oct12be08975dLab Smp Id BFB Inj Date 11-OCT-2012 2008 Operator VOAMS 1 Inst ID VOAMS5iSmp Info BFBMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12bBFBDELmMeth Date 27-Feb-2012 1508 sylvanus Quant Type ISTDCal Date Cal File Als bottle 2 QC Sample BFBDil Factor 100000 Integrator HP RTE Compound Sublist allsubTarget Version 350 Sample Matrix WATERProcessing Host hpd2

Concentration Formula Amt DF Uf Vf VI CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorUf 100000 ng unit correction factorVf 100000 Volumetric correction factorVI 100000 Injection Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT (REL RT) MASS RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ==== ======== ======= ======= ============ =====

1 BFB CAS 460-00-4

2352 2600 (0000) 95 135522 000- 10000 10000

2352 2600 (0000) 50 29541 1500- 4000 2180

2352 2600 (0000) 75 70179 3000- 6000 5178

2352 2600 (0000) 96 8846 500- 900 653

2352 2600 (0000) 173 896 000- 200 074

2352 2600 (0000) 174 121433 5000- 10000 8960

2352 2600 (0000) 175 9704 500- 900 799

2352 2600 (0000) 176 118148 9500- 10100 9729

2352 2600 (0000) 177 7241 500- 900 613

-------------------------------------------------------------------------------

10162012Page 110 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

10162012Page 111 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

1 BFB

RELATIVE me ION ABUNDANCE CRITERIA ABUNDANCE

+-----+------------------------------------------+---------------------+| | | || 95 | Base Peak 100 relative abundance | 10000 || 50 | 1500 - 4000 of mass 95 | 2180 || 75 | 3000 - 6000 of mass 95 | 5178 || 96 | 500 - 900 of mass 95 | 653 || 173 | Less than 200 of mass 174 | 066 ( 074) || 174 | 5000 - 10000 of mass 95 | 8960 || 175 | 500 - 900 of mass 174 | 716 ( 799) || 176 | 9500 - 10100 of mass 174 | 8718 ( 9729) || 177 | 500 - 900 of mass 176 | 534 ( 613) |+-----+------------------------------------------+---------------------+

10162012Page 112 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

Data File chemVOAMS5i8260DE09-17-1211oct12be08975dSpectrum Avg Scans 50-52 ( 235) Background Scan 46

Location of Maximum 9500Number of points 149

mz Y mz Y mz Y mz Y+------------------+------------------+------------------+------------------+| 3600 1294 | 7800 45 | 13100 382 | 18200 69 || 3700 8431 | 7900 4274 | 13200 84 | 18300 115 || 3800 6991 | 8000 1313 | 13400 26 | 18600 116 || 3900 2548 | 8100 3602 | 13500 465 | 18700 340 || 4000 550 | 8200 868 | 13600 63 | 18800 34 |+------------------+------------------+------------------+------------------+| 4100 253 | 8300 128 | 13700 225 | 18900 18 || 4200 100 | 8400 171 | 13900 69 | 19900 265 || 4400 553 | 8500 53 | 14000 115 | 20100 29 || 4500 1283 | 8700 5211 | 14100 1442 | 20400 84 || 4700 1587 | 8800 4550 | 14200 269 | 20500 33 |+------------------+------------------+------------------+------------------+| 4800 651 | 9100 642 | 14300 1465 | 20600 138 || 4900 5880 | 9200 3657 | 14400 23 | 20700 20 || 5000 29536 | 9300 6715 | 14500 103 | 20900 79 || 5100 8612 | 9400 15687 | 14700 151 | 21000 74 || 5200 396 | 9500 135488 | 14800 365 | 21100 1 |+------------------+------------------+------------------+------------------+| 5300 107 | 9600 8846 | 14900 429 | 21200 140 || 5500 726 | 9700 271 | 15100 54 | 21300 52 || 5600 1691 | 9800 1 | 15300 430 | 21400 189 || 5700 4463 | 10000 110 | 15400 385 | 22100 72 || 5800 245 | 10300 207 | 15500 1021 | 22200 35 |+------------------+------------------+------------------+------------------+| 5900 116 | 10400 668 | 15600 236 | 22400 188 || 6000 1281 | 10600 562 | 15700 473 | 22600 79 || 6100 6975 | 10700 159 | 15800 3 | 22800 39 || 6200 7260 | 11000 145 | 15900 410 | 23000 95 || 6300 5465 | 11100 68 | 16100 441 | 23300 189 |+------------------+------------------+------------------+------------------+| 6400 672 | 11200 80 | 16400 208 | 23400 42 || 6500 144 | 11300 261 | 16500 57 | 23500 36 || 6600 201 | 11600 813 | 17000 641 | 23600 58 || 6700 729 | 11700 882 | 17100 38 | 24100 103 || 6800 14333 | 11800 446 | 17200 338 | 24700 36 |+------------------+------------------+------------------+------------------+| 6900 14506 | 11900 1049 | 17300 896 | 25100 40 || 7000 1361 | 12000 38 | 17400 121432 | 25500 61 || 7200 782 | 12100 249 | 17500 9704 | 25600 33 || 7300 6586 | 12400 108 | 17600 118144 | 26000 59 || 7400 24016 | 12600 138 | 17700 7241 | 26500 78 |+------------------+------------------+------------------+------------------+| 7500 70176 | 12700 39 | 17900 19 | || 7600 5444 | 12900 479 | 18000 29 | || 7700 507 | 13000 702 | 18100 322 | |+------------------+------------------+------------------+------------------+

10162012Page 113 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014U1634-04-4 Methyl tert-butyl ether 014

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 114 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

99 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

95 70-130460-00-4 4-Bromofluorobenzene

96 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 115 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 116 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08981d Report Date 12-Oct-2012 0041

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08981dLab Smp Id MB Inj Date 11-OCT-2012 2247 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info MBMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 6 QC Sample BLANKDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 381607 495518 50

52 Fluorobenzene 96 3595 3601 (1000) 1238441 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1209056 482553 48

78 Chlorobenzene-d5 117 6954 6954 (1000) 1084553 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 494380 477044 48

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 638826 500000

10162012Page 117 of 323

Data File e08981d

Date 11-OCT-2012 2247

Client ID Instrument VOAMS5i

Sample Info MB Operator GCMS VOAMS5

10162012Page 118 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1316563

Matrix e08977dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2113

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 006071-55-6 111-Trichloroethane 210

10 02275-71-8 Dichlorodifluoromethane 181

10 01074-87-3 Chloromethane 210

10 01475-01-4 Vinyl chloride 203

10 01874-83-9 Bromomethane 211

10 04096-12-8 12-Dibromo-3-Chloropropane 222

10 02195-50-1 12-Dichlorobenzene 209

10 01575-69-4 Trichlorofluoromethane 190

10 009075-35-4 11-Dichloroethene 223

10 009078-87-5 12-Dichloropropane 211

10 008076-13-1 112-Trichloro-122-trifluoroethane

203

50 2767-64-1 Acetone 250

10 01375-15-0 Carbon disulfide 218

20 03479-20-9 Methyl acetate 220

10 01875-09-2 Methylene Chloride 200

10 013156-60-5 trans-12-Dichloroethene 216

10 020124-48-1 Chlorodibromomethane 217

10 0141634-04-4 Methyl tert-butyl ether 207

10 01775-00-3 Chloroethane 201

10 01375-34-3 11-Dichloroethane 204

10 018156-59-2 cis-12-Dichloroethene 211

50 2378-93-3 2-Butanone (MEK) 214

10 008067-66-3 Chloroform 205

10 010100-41-4 Ethylbenzene 206

10 016110-82-7 Cyclohexane 208

10 006056-23-5 Carbon tetrachloride 211

10 008071-43-2 Benzene 212

10 019107-06-2 12-Dichloroethane 204

10 009079-01-6 Trichloroethene 212

10 014108-87-2 Methylcyclohexane 215

10 01275-27-4 Dichlorobromomethane 214

10 01810061-01-5 cis-13-Dichloropropene 216

50 099108-10-1 4-Methyl-2-pentanone (MIBK) 214

10 015108-88-3 Toluene 205

10 02410061-02-6 trans-13-Dichloropropene 215

FORM I 8260B

10162012Page 119 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1316563

Matrix e08977dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2113

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 01979-00-5 112-Trichloroethane 217

10 010127-18-4 Tetrachloroethene 210

50 050591-78-6 2-Hexanone 201

10 028106-93-4 12-Dibromoethane 215

10 011108-90-7 Chlorobenzene 206

30 0361330-20-7 Xylenes Total 612

10 012100-42-5 Styrene 207

10 01975-25-2 Bromoform 217

10 008098-82-8 Isopropylbenzene 207

10 01679-34-5 1122-Tetrachloroethane 210

10 014541-73-1 13-Dichlorobenzene 204

10 023106-46-7 14-Dichlorobenzene 204

10 034120-82-1 124-Trichlorobenzene 220

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

97 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 120 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08977d Report Date 11-Oct-2012 2301

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08977dLab Smp Id LCS Inj Date 11-OCT-2012 2113 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info LCSMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 2 QC Sample BSDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 92905 180886 18

3 Chloromethane 50 1016 1016 (0283) 178821 210339 21

4 Vinyl Chloride 62 1022 1028 (0284) 146748 202753 20

6 Bromomethane 94 1181 1181 (0328) 88580 210689 21

5 Chloroethane 64 1236 1242 (0344) 67759 201399 20

7 Trichlorofluoromethane 101 1297 1303 (0361) 148657 190423 19

14 Freon TF 101 1565 1577 (0435) 106548 203057 20

15 11-Dichloroethene 96 1547 1553 (0430) 94737 223085 22

16 Acetone 58 1900 1894 (0529) 14083 249674 25

18 Carbon Disulfide 76 1565 1571 (0435) 377236 218062 22

27 Methyl Acetate 74 1961 1967 (0546) 21873 219755 22

22 Methylene Chloride 49 1858 1864 (0517) 180593 200499 20

28 MTBE 73 2022 2022 (0562) 363998 207251 21

25 trans-12-Dichloroethene 96 1943 1949 (0540) 119022 216004 22

30 11-Dichloroethane 63 2303 2309 (0640) 238759 204130 20

36 cis-12-Dichloroethene 96 2650 2656 (0737) 126688 211021 21

10162012Page 121 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08977d Report Date 11-Oct-2012 2301

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 20020 214276 21

42 Chloroform 83 2845 2845 (0791) 215227 205163 20

44 Cyclohexane 56 2778 2784 (0773) 186275 208395 21

43 111-Trichloroethane 97 2979 2985 (0829) 195599 210453 21

45 Carbon Tetrachloride 117 2931 2937 (0815) 156464 210644 21

48 Benzene 78 3260 3260 (0469) 500200 211727 21

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 391700 477589 48

49 12-Dichloroethane 62 3412 3418 (0949) 178793 204379 20

52 Fluorobenzene 96 3595 3601 (1000) 1318918 500000

54 Trichloroethene 95 3735 3741 (1039) 127803 211922 21

56 Methyl cyclohexane 83 3723 3729 (1036) 159134 214991 21

57 12-Dichloropropane 63 4192 4199 (1166) 134808 211159 21

68 Bromodichloromethane 83 4272 4272 (1188) 171399 214054 21

67 cis-13-Dichloropropene 75 4906 4912 (0705) 217526 216258 22

70 4-Methyl-2-Pentanone 43 5631 5625 (0810) 134218 214248 21

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1312817 495616 50

66 Toluene 91 5162 5162 (0742) 572353 205343 20

64 trans-13-Dichloropropene 75 5650 5649 (0812) 195539 215018 22

69 112-Trichloroethane 83 5820 5820 (0837) 92220 217218 22

71 Tetrachloroethene 166 5582 5582 (0803) 145712 209847 21

73 2-Hexanone 43 6680 6680 (0961) 96649 200980 20

74 Dibromochloromethane 129 6015 6021 (0865) 132048 217333 22

77 12-Dibromoethane 107 6259 6265 (0900) 113742 214758 21

78 Chlorobenzene-d5 117 6954 6954 (1000) 1146590 500000

79 Chlorobenzene 112 6972 6972 (1003) 392243 206030 21

81 Ethylbenzene 106 7064 7064 (1016) 206211 205716 20

82 m+p-Xylene 106 7277 7277 (1046) 519872 407882 41

84 o-Xylene 106 7856 7862 (1130) 254939 203845 20

85 Styrene 104 7942 7942 (1142) 437977 207191 21

86 Bromoform 173 7911 7911 (1138) 93696 217219 22

88 Isopropylbenzene 105 8344 8350 (1200) 637526 207206 21

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 538047 484974 48

92 1122-Tetrachloroethane 83 9112 9112 (0871) 147339 210261 21

105 13-Dichlorobenzene 146 10325 10331 (0987) 330263 203584 20

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 683882 500000

109 14-Dichlorobenzene 146 10484 10490 (1002) 343961 204369 20

111 12-Dichlorobenzene 146 11148 11148 (1065) 320073 208797 21

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 26198 222454 22

114 124-Trichlorobenzene 180 12977 12977 (1240) 189475 219787 22

M 120 12-Dichloroethene (Total) 100 245711 427025 43

M 121 Xylene (Total) 100 774811 611727 61

10162012Page 122 of 323

Data File e08977d

Date 11-OCT-2012 2113

Client ID Instrument VOAMS5i

Sample Info LCS Operator GCMS VOAMS5

10162012Page 123 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MS

Matrix e08985dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0027

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 03071-55-6 111-Trichloroethane 103

50 1175-71-8 Dichlorodifluoromethane 865

50 05074-87-3 Chloromethane 102

50 07075-01-4 Vinyl chloride 104

50 09074-83-9 Bromomethane 107

50 2096-12-8 12-Dibromo-3-Chloropropane 121

50 1195-50-1 12-Dichlorobenzene 107

50 07575-69-4 Trichlorofluoromethane 121

50 04575-35-4 11-Dichloroethene 108

50 04578-87-5 12-Dichloropropane 111

50 04076-13-1 112-Trichloro-122-trifluoroethane

102

25 1367-64-1 Acetone 986

50 06575-15-0 Carbon disulfide 113

10 1779-20-9 Methyl acetate 100

50 09075-09-2 Methylene Chloride 106

50 065156-60-5 trans-12-Dichloroethene 106

50 10124-48-1 Chlorodibromomethane 116

50 0701634-04-4 Methyl tert-butyl ether 114

50 08575-00-3 Chloroethane 116

50 06575-34-3 11-Dichloroethane 104

50 090156-59-2 cis-12-Dichloroethene 105

25 1278-93-3 2-Butanone (MEK) 111

50 04067-66-3 Chloroform 108

50 050100-41-4 Ethylbenzene 107

50 080110-82-7 Cyclohexane 108

50 03056-23-5 Carbon tetrachloride 105

50 04071-43-2 Benzene 106

50 095107-06-2 12-Dichloroethane 107

50 04579-01-6 Trichloroethene 107

50 070108-87-2 Methylcyclohexane 115

50 06075-27-4 Dichlorobromomethane 113

50 09010061-01-5 cis-13-Dichloropropene 109

25 50108-10-1 4-Methyl-2-pentanone (MIBK) 111

50 075108-88-3 Toluene 106

50 1210061-02-6 trans-13-Dichloropropene 113

FORM I 8260B

10162012Page 124 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MS

Matrix e08985dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0027

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 09579-00-5 112-Trichloroethane 112

50 050127-18-4 Tetrachloroethene 110

25 25591-78-6 2-Hexanone 109

50 14106-93-4 12-Dibromoethane 116

50 055108-90-7 Chlorobenzene 107

15 181330-20-7 Xylenes Total 318

50 060100-42-5 Styrene 107

50 09575-25-2 Bromoform 115

50 04098-82-8 Isopropylbenzene 107

50 08079-34-5 1122-Tetrachloroethane 115

50 070541-73-1 13-Dichlorobenzene 106

50 12106-46-7 14-Dichlorobenzene 106

50 17120-82-1 124-Trichlorobenzene 110

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 125 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08985d Report Date 12-Oct-2012 0117

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08985dLab Smp Id 460-45537-C-2 MS Inj Date 12-OCT-2012 0027 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-C-2 MS5Misc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 10 QC Sample MSDil Factor 500000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 500000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 83204 173010 86

3 Chloromethane 50 1016 1016 (0283) 161645 203059 100

4 Vinyl Chloride 62 1022 1028 (0284) 141501 208792 100

6 Bromomethane 94 1181 1181 (0328) 84568 214819 110

5 Chloroethane 64 1236 1242 (0344) 73104 232055 120

7 Trichlorofluoromethane 101 1297 1303 (0361) 177163 242363 120

14 Freon TF 101 1571 1577 (0437) 100496 204542 100

15 11-Dichloroethene 96 1553 1553 (0432) 86070 216451 110

16 Acetone 58 1894 1894 (0527) 10416 197218 99

18 Carbon Disulfide 76 1565 1571 (0435) 366514 226264 110

27 Methyl Acetate 74 1961 1967 (0546) 18655 200164 100

22 Methylene Chloride 49 1857 1864 (0517) 178536 211689 100

28 MTBE 73 2016 2022 (0561) 376182 228747 110

25 trans-12-Dichloroethene 96 1949 1949 (0542) 109215 211677 100

30 11-Dichloroethane 63 2309 2309 (0642) 226749 207039 100

36 cis-12-Dichloroethene 96 2650 2656 (0737) 118569 210921 100

10162012Page 126 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08985d Report Date 12-Oct-2012 0117

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 19396 221710 110

42 Chloroform 83 2845 2845 (0791) 213034 216876 110

44 Cyclohexane 56 2784 2784 (0774) 180984 216238 110

43 111-Trichloroethane 97 2979 2985 (0829) 179996 206829 100

45 Carbon Tetrachloride 117 2930 2937 (0815) 145570 209299 100

48 Benzene 78 3260 3260 (0469) 482493 212344 110

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 369860 481613 48

49 12-Dichloroethane 62 3418 3418 (0951) 175178 213858 110

52 Fluorobenzene 96 3595 3601 (1000) 1234975 500000

54 Trichloroethene 95 3741 3741 (1041) 121196 214627 110

56 Methyl cyclohexane 83 3729 3729 (1037) 158792 229110 110

57 12-Dichloropropane 63 4192 4199 (1166) 132380 221450 110

68 Bromodichloromethane 83 4272 4272 (1188) 168703 225007 110

67 cis-13-Dichloropropene 75 4906 4912 (0705) 211819 218949 110

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 133223 221106 110

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1260222 494657 49

66 Toluene 91 5162 5162 (0742) 566751 211409 100

64 trans-13-Dichloropropene 75 5649 5649 (0812) 197737 226072 110

69 112-Trichloroethane 83 5820 5820 (0837) 91872 224994 110

71 Tetrachloroethene 166 5582 5582 (0803) 147320 220590 110

73 2-Hexanone 43 6674 6680 (0960) 100809 217957 110

74 Dibromochloromethane 129 6015 6021 (0865) 135240 231427 120

77 12-Dibromoethane 107 6259 6265 (0900) 117784 231222 120

78 Chlorobenzene-d5 117 6954 6954 (1000) 1102789 500000

79 Chlorobenzene 112 6972 6972 (1003) 391979 214069 110

81 Ethylbenzene 106 7064 7064 (1016) 207079 214786 110

82 m+p-Xylene 106 7277 7277 (1046) 521861 425705 210

84 o-Xylene 106 7856 7862 (1130) 254032 211187 100

85 Styrene 104 7942 7942 (1142) 433507 213222 110

86 Bromoform 173 7911 7911 (1138) 95433 230033 120

88 Isopropylbenzene 105 8350 8350 (1201) 635772 214844 110

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 518047 497030 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 151817 230609 120

105 13-Dichlorobenzene 146 10325 10331 (0987) 322106 211348 100

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 642491 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 334190 211356 100

111 12-Dichlorobenzene 146 11148 11148 (1065) 308704 214355 110

112 12-Dibromo-3-chloropropane 75 12233 12234 (1169) 26873 242889 120(R)

114 124-Trichlorobenzene 180 12977 12977 (1240) 177853 219597 110

M 120 12-Dichloroethene (Total) 100 227784 422599 210

M 121 Xylene (Total) 100 775893 636892 320

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 127 of 323

Data File e08985d

Date 12-OCT-2012 0027

Client ID Instrument VOAMS5i

Sample Info 460-45537-C-2 MS5 Operator GCMS VOAMS5

10162012Page 128 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MSD

Matrix e08986dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0051

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 03071-55-6 111-Trichloroethane 106

50 1175-71-8 Dichlorodifluoromethane 896

50 05074-87-3 Chloromethane 101

50 07075-01-4 Vinyl chloride 105

50 09074-83-9 Bromomethane 105

50 2096-12-8 12-Dibromo-3-Chloropropane 121

50 1195-50-1 12-Dichlorobenzene 111

50 07575-69-4 Trichlorofluoromethane 997

50 04575-35-4 11-Dichloroethene 119

50 04578-87-5 12-Dichloropropane 110

50 04076-13-1 112-Trichloro-122-trifluoroethane

111

25 1367-64-1 Acetone 101

50 06575-15-0 Carbon disulfide 119

10 1779-20-9 Methyl acetate 101

50 09075-09-2 Methylene Chloride 106

50 065156-60-5 trans-12-Dichloroethene 108

50 10124-48-1 Chlorodibromomethane 118

50 0701634-04-4 Methyl tert-butyl ether 116

50 08575-00-3 Chloroethane 105

50 06575-34-3 11-Dichloroethane 111

50 090156-59-2 cis-12-Dichloroethene 109

25 1278-93-3 2-Butanone (MEK) 114

50 04067-66-3 Chloroform 113

50 050100-41-4 Ethylbenzene 111

50 080110-82-7 Cyclohexane 117

50 03056-23-5 Carbon tetrachloride 110

50 04071-43-2 Benzene 114

50 095107-06-2 12-Dichloroethane 109

50 04579-01-6 Trichloroethene 113

50 070108-87-2 Methylcyclohexane 121

50 06075-27-4 Dichlorobromomethane 116

50 09010061-01-5 cis-13-Dichloropropene 115

25 50108-10-1 4-Methyl-2-pentanone (MIBK) 114

50 075108-88-3 Toluene 111

50 1210061-02-6 trans-13-Dichloropropene 119

FORM I 8260B

10162012Page 129 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MSD

Matrix e08986dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0051

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 09579-00-5 112-Trichloroethane 116

50 050127-18-4 Tetrachloroethene 116

25 25591-78-6 2-Hexanone 111

50 14106-93-4 12-Dibromoethane 117

50 055108-90-7 Chlorobenzene 111

15 181330-20-7 Xylenes Total 329

50 060100-42-5 Styrene 110

50 09575-25-2 Bromoform 114

50 04098-82-8 Isopropylbenzene 111

50 08079-34-5 1122-Tetrachloroethane 116

50 070541-73-1 13-Dichlorobenzene 110

50 12106-46-7 14-Dichlorobenzene 110

50 17120-82-1 124-Trichlorobenzene 119

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

97 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 130 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08986d Report Date 12-Oct-2012 0118

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08986dLab Smp Id 460-45537-C-2 MSD Inj Date 12-OCT-2012 0051 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-C-2 MSD5Misc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 11 QC Sample MSDDil Factor 500000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 500000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 90471 179208 90

3 Chloromethane 50 1016 1016 (0283) 169425 202751 100

4 Vinyl Chloride 62 1022 1028 (0284) 149176 209689 100

6 Bromomethane 94 1181 1181 (0328) 86595 209548 100

5 Chloroethane 64 1236 1242 (0344) 69668 210673 100

7 Trichlorofluoromethane 101 1297 1303 (0361) 152935 199307 100

14 Freon TF 101 1565 1577 (0435) 114134 221294 110

15 11-Dichloroethene 96 1547 1553 (0430) 98966 237094 120

16 Acetone 58 1900 1894 (0529) 11165 201386 100

18 Carbon Disulfide 76 1565 1571 (0435) 405349 238385 120

27 Methyl Acetate 74 1961 1967 (0546) 19684 201192 100

22 Methylene Chloride 49 1858 1864 (0517) 187993 212342 110

28 MTBE 73 2022 2022 (0562) 399850 231621 120(R)

25 trans-12-Dichloroethene 96 1943 1949 (0540) 117162 216323 110

30 11-Dichloroethane 63 2309 2309 (0642) 255983 222660 110

36 cis-12-Dichloroethene 96 2650 2656 (0737) 129220 218978 110

10162012Page 131 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08986d Report Date 12-Oct-2012 0118

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 20938 227991 110

42 Chloroform 83 2845 2845 (0791) 233404 226357 110

44 Cyclohexane 56 2778 2784 (0773) 204751 233046 120

43 111-Trichloroethane 97 2979 2985 (0829) 194508 212915 110

45 Carbon Tetrachloride 117 2931 2937 (0815) 161111 220670 110

48 Benzene 78 3260 3260 (0469) 525066 227601 110

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 386156 479012 48

49 12-Dichloroethane 62 3412 3418 (0949) 188223 218898 110

52 Fluorobenzene 96 3595 3601 (1000) 1296388 500000

54 Trichloroethene 95 3741 3741 (1041) 133629 225434 110

56 Methyl cyclohexane 83 3723 3729 (1036) 175741 241553 120

57 12-Dichloropropane 63 4192 4199 (1166) 138376 220515 110

68 Bromodichloromethane 83 4272 4272 (1188) 182026 231276 120

67 cis-13-Dichloropropene 75 4906 4912 (0705) 226245 230339 120

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 139423 227913 110

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1279885 494812 49

66 Toluene 91 5162 5162 (0742) 602122 221221 110

64 trans-13-Dichloropropene 75 5650 5649 (0812) 211878 238592 120(R)

69 112-Trichloroethane 83 5820 5820 (0837) 95786 231047 120

71 Tetrachloroethene 166 5582 5582 (0803) 157152 231769 120

73 2-Hexanone 43 6680 6680 (0961) 103997 221464 110

74 Dibromochloromethane 129 6015 6021 (0865) 140562 236912 120

77 12-Dibromoethane 107 6259 6265 (0900) 120913 233791 120

78 Chlorobenzene-d5 117 6954 6954 (1000) 1119645 500000

79 Chlorobenzene 112 6972 6972 (1003) 411739 221475 110

81 Ethylbenzene 106 7064 7064 (1016) 216984 221672 110

82 m+p-Xylene 106 7277 7277 (1046) 549474 441482 220

84 o-Xylene 106 7856 7862 (1130) 265488 217389 110

85 Styrene 104 7942 7942 (1142) 452927 219420 110

86 Bromoform 173 7911 7911 (1138) 96039 228008 110

88 Isopropylbenzene 105 8344 8350 (1200) 668990 222665 110

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 517679 487311 49

92 1122-Tetrachloroethane 83 9112 9112 (0871) 155509 231763 120

105 13-Dichlorobenzene 146 10325 10331 (0987) 342279 220349 110

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 654839 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 355256 220442 110

111 12-Dichlorobenzene 146 11148 11148 (1065) 324646 221173 110

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 27355 242581 120(R)

114 124-Trichlorobenzene 180 12977 12977 (1240) 196651 238228 120

M 120 12-Dichloroethene (Total) 100 246382 435302 220

M 121 Xylene (Total) 100 814963 658871 330

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 132 of 323

Data File e08986d

Date 12-OCT-2012 0051

Client ID Instrument VOAMS5i

Sample Info 460-45537-C-2 MSD5 Operator GCMS VOAMS5

10162012Page 133 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GCMS VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

VOAMS5

128076

Start Date

End Date 09172012 1616

09172012 0324

BFB 460-1280761 Rtx-VMS 018(mm)109172012 0324 e07834d

IC 460-1280762 Rtx-VMS 018(mm)109172012 0449 e07836d

IC 460-1280763 Rtx-VMS 018(mm)109172012 0536 e07838d

ICIS 460-1280764 Rtx-VMS 018(mm)109172012 0600 e07839d

IC 460-1280765 Rtx-VMS 018(mm)109172012 0623 e07840d

IC 460-1280766 Rtx-VMS 018(mm)109172012 0646 e07841d

IC 460-1280767 Rtx-VMS 018(mm)109172012 0710 e07842d

ZZZZZ Rtx-VMS 018(mm)109172012 0937

ZZZZZ Rtx-VMS 018(mm)109172012 1047

ZZZZZ Rtx-VMS 018(mm)109172012 1111

ZZZZZ Rtx-VMS 018(mm)109172012 1134

ZZZZZ Rtx-VMS 018(mm)109172012 1157

ZZZZZ Rtx-VMS 018(mm)509172012 1221

ZZZZZ Rtx-VMS 018(mm)509172012 1244

ZZZZZ Rtx-VMS 018(mm)109172012 1307

ZZZZZ Rtx-VMS 018(mm)109172012 1331

ZZZZZ Rtx-VMS 018(mm)109172012 1354

ZZZZZ Rtx-VMS 018(mm)109172012 1417

ZZZZZ Rtx-VMS 018(mm)109172012 1441

CCV 460-12807620 Rtx-VMS 018(mm)109172012 1616

8260B

10162012Page 134 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GCMS VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

VOAMS5

131656

Start Date

End Date 10122012 0114

10112012 2008

BFB 460-1316561 Rtx-VMS 018(mm)110112012 2008 e08975d

CCVIS 460-1316562 Rtx-VMS 018(mm)110112012 2050 e08976d

LCS 460-1316563 Rtx-VMS 018(mm)110112012 2113 e08977d

MB 460-1316564 Rtx-VMS 018(mm)110112012 2247 e08981d

460-45537-3 TB-17338-100512-253 Rtx-VMS 018(mm)110112012 2317 e08982d

460-45537-1 WC-17338-100512-MW14-MM-251

Rtx-VMS 018(mm)110112012 2341 e08983d

460-45537-2 WC-17338-100512-MW101-MM-252

Rtx-VMS 018(mm)110122012 0004 e08984d

460-45537-2 MS WC-17338-100512-MW101-MM-252 MS

Rtx-VMS 018(mm)510122012 0027 e08985d

460-45537-2 MSD WC-17338-100512-MW101-MM-252 MSD

Rtx-VMS 018(mm)510122012 0051 e08986d

CCV 460-13165610 Rtx-VMS 018(mm)110122012 0114 e08987d

8260B

10162012Page 135 of 323

10162012Page 136 of 323

10162012Page 137 of 323

10162012Page 138 of 323

10162012Page 139 of 323

Method 8082 -

DelawarePolychlorinated Biphenyls (PCBs)

(GC) by Method 8082 (Delaware)

10162012Page 140 of 323

FORM II

GC SEMI VOA SURROGATE RECOVERY

Lab Name Job No 460-45537-1

SDG No

Matrix Water Level Low

TestAmerica Edison

GC Column (1) ID (mm) GC Column (2) ID (mm)CLP-1 053 CLP-2 053

Lab Sample IDClient Sample ID DCB1 DCB2

460-45537-1WC-17338-100512-MW14-MM-251

82 83

460-45537-2WC-17338-100512-MW101-MM-252

52 50

MB 460-1309971-A

97 88

LCS 460-1309972-A

91 84

LCSD 460-1309973-A

108 99

QC LIMITSQC LIMITSDCB = DCB Decachlorobiphenyl 37-150

FORM II 8082

Column to be used to flag recovery values

10162012Page 141 of 323

GC SEMI VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vf479497dWater

Lab ID LCS 460-1309972-A Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

PCB-1016 500 507 71-126101

PCB-1260 500 557 73-130111

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 142 of 323

GC SEMI VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vr479497dWater

Lab ID LCS 460-1309972-A Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

PCB-1016 500 483 71-12697

PCB-1260 500 573 73-130115

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 143 of 323

GC SEMI VOA LAB CONTROL SAMPLE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vf479498dWater

Lab ID LCSD 460-1309973-A Client ID

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

LCSD LCSD

500 516 30 71-126PCB-1016 2103

500 583 30 73-130PCB-1260 5117

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 144 of 323

GC SEMI VOA LAB CONTROL SAMPLE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vr479498dWater

Lab ID LCSD 460-1309973-A Client ID

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

LCSD LCSD

500 497 30 71-126PCB-1016 399

500 595 30 73-130PCB-1260 4119

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 145 of 323

FORM IV

GC SEMI VOA METHOD BLANK SUMMARY

Lab Name

SDG No

Job No 460-45537-1TestAmerica Edison

Date Analyzed(1)

Instrument ID(1)

GC Column(1) ID

Instrument ID(2)

Date Extracted 10082012 0755

Date Analyzed(2)

GC Column(2) IDCLP-2053(mm) 053(mm)

PESTGC9

10082012 2208

Lab File ID(1) Lab File ID(2)

Matrix Water

vf479496d

Lab Sample ID MB 460-1309971-A

vr479496d

10082012 2208

PESTGC9

CLP-1

THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES

ANALYZED 2

DATEDATE

ANALYZED 1LAB SAMPLE IDCLIENT SAMPLE ID

LCS 460-1309972-A 10082012 2224 10082012 2224

LCSD 460-1309973-A 10082012 2239 10082012 2239

460-45537-1WC-17338-100512-MW14-MM-251

10092012 0029 10092012 0029

460-45537-2WC-17338-100512-MW101-MM-252

10092012 0045 10092012 0045

FORM IV 8082

10162012Page 146 of 323

GC SEMI VOA ANALYTICAL SEQUENCE

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVRT 460-1311372 Date Analyzed 10082012 1830

Lab File ID (Standard) vf479493d

Instrument ID PESTGC9 GC Column CLP-2 ID 053(mm)

Heated Purge (YN) N

Calibration ID 17840

THE ANALYTICAL SEQUENCE OF BLANKS SAMPLES STANDARDS MSMSDs AND LCSs IS GIVEN BELOW

RT

DCB

UPPER LIMIT

LOWER LIMIT

1159

1139

CONTINUING CALIBRATION SURROGATE 1149

LAB SAMPLE ID DATE ANALYZEDCLIENT SAMPLE ID LAB FILE ID

CCVRT 460-1311372 10082012 1830 1149vf479493d

MB 460-1309971-A 10082012 2208 1148vf479496d

LCS 460-1309972-A 10082012 2224 1148vf479497d

LCSD 460-1309973-A 10082012 2239 1148vf479498d

460-45537-1 10092012 0029 1149WC-17338-100512-MW14-MM-251

vf479505d

460-45537-2 10092012 0045 1149WC-17338-100512-MW101-MM-252

vf479506d

PIBLK 460-13113718 10092012 0131 1149vf479509d

CCV 460-13113719 10092012 0147 1149vf479510d

DCB = DCB Decachlorobiphenyl

DCB RT Limit = plusmn 01 minutes of surrogate RT

Column used to flag values outside QC limits

FORM VIII 8082

10162012Page 147 of 323

GC SEMI VOA ANALYTICAL SEQUENCE

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVRT 460-1311372 Date Analyzed 10082012 1830

Lab File ID (Standard) vr479493d

Instrument ID PESTGC9 GC Column CLP-1 ID 053(mm)

Heated Purge (YN) N

Calibration ID 17839

THE ANALYTICAL SEQUENCE OF BLANKS SAMPLES STANDARDS MSMSDs AND LCSs IS GIVEN BELOW

RT

DCB

UPPER LIMIT

LOWER LIMIT

1071

1051

CONTINUING CALIBRATION SURROGATE 1061

LAB SAMPLE ID DATE ANALYZEDCLIENT SAMPLE ID LAB FILE ID

CCVRT 460-1311372 10082012 1830 1061vr479493d

MB 460-1309971-A 10082012 2208 1061vr479496d

LCS 460-1309972-A 10082012 2224 1061vr479497d

LCSD 460-1309973-A 10082012 2239 1061vr479498d

460-45537-1 10092012 0029 1061WC-17338-100512-MW14-MM-251

vr479505d

460-45537-2 10092012 0045 1061WC-17338-100512-MW101-MM-252

vr479506d

PIBLK 460-13113718 10092012 0131 1061vr479509d

CCV 460-13113719 10092012 0147 1061vr479510d

DCB = DCB Decachlorobiphenyl

DCB RT Limit = plusmn 01 minutes of surrogate RT

Column used to flag values outside QC limits

FORM VIII 8082

10162012Page 148 of 323

FORM XForm 1

Client Sample ID

Lab Name Job No

SDG No

Lab Sample ID LCS 460-1309972-A

Instrument ID (1) Instrument ID (2)

Date Analyzed (1) Date Analyzed (2)

GC Column (1) ID GC Column (2) ID

TestAmerica Edison 460-45537-1

IDENTIFICATION SUMMARYForm 1

053(mm) 053(mm)

10082012 2224 10082012 2224

PESTGC9 PESTGC9

CLP-1 CLP-2

ANALYTE COL PEAK RTRT WINDOW

FROM TO PEAK MEAN

CONCENTRATIONRPD

PCB-1016 1 1 206 201 215 473 483 47

2 250 246 260 494

3 275 271 285 530

4 310 306 320 501

5 330 326 340 520

6 369 361 375 302

7 401 397 411 541

8 419 412 426 505

2 1 293 289 303 525 507

2 360 357 371 562

3 404 401 415 567

4 444 441 455 558

5 468 465 479 594

6 518 509 523 402

7 557 547 561 259

8 571 568 582 584

PCB-1260 1 1 605 600 614 554 573 28

2 650 645 659 558

3 694 689 703 581

4 714 709 723 548

5 758 753 767 565

6 886 882 896 559

7 908 904 918 619

8 1014 1008 1022 600

2 1 771 769 783 600 557

2 817 814 828 594

3 903 901 915 625

4 928 926 940 622

5 941 938 952 643

6 986 983 997 612

7 1062 1055 1069 212

8 1106 1102 1116 550

FORM X 8082

10162012Page 149 of 323

FORM XForm 1

Client Sample ID

Lab Name Job No

SDG No

Lab Sample ID LCSD 460-1309973-A

Instrument ID (1) Instrument ID (2)

Date Analyzed (1) Date Analyzed (2)

GC Column (1) ID GC Column (2) ID

TestAmerica Edison 460-45537-1

IDENTIFICATION SUMMARYForm 1

053(mm) 053(mm)

10082012 2239 10082012 2239

PESTGC9 PESTGC9

CLP-1 CLP-2

ANALYTE COL PEAK RTRT WINDOW

FROM TO PEAK MEAN

CONCENTRATIONRPD

PCB-1016 1 1 206 201 215 483 497 38

2 250 246 260 505

3 275 271 285 542

4 310 306 320 510

5 330 326 340 529

6 368 361 375 369

7 401 397 411 549

8 419 412 426 491

2 1 292 289 303 535 516

2 359 357 371 574

3 404 401 415 572

4 443 441 455 572

5 468 465 479 606

6 518 509 523 407

7 557 547 561 267

8 571 568 582 599

PCB-1260 1 1 605 600 614 565 595 19

2 650 645 659 571

3 694 689 703 595

4 714 709 723 563

5 757 753 767 585

6 886 882 896 582

7 908 904 918 656

8 1014 1008 1022 639

2 1 771 769 783 615 583

2 816 814 828 610

3 902 901 915 645

4 928 926 940 648

5 940 938 952 669

6 986 983 997 637

7 1062 1055 1069 253

8 1106 1102 1116 590

FORM X 8082

10162012Page 150 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix vf479505dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1000

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0029

5(mL)

Sample wtvol 980(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

83 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 151 of 323

Data File vf479505d Report Date 09-Oct-2012 0313

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479505dLab Smp Id 460-45537-E-1-B Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0029 Operator Inst ID PESTGC9iSmp Info 460-45537-E-1-BMisc Info 460-45537-E-1-BComment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 35 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 98000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11489 11515 -0026 22061081 829479 042 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 152 of 323

Data File vf479505d

Date 09-OCT-2012 0029

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-1-B Operator

10162012Page 153 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix vr479505dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1000

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0029

5(mL)

Sample wtvol 980(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

051 013U12674-11-2 PCB-1016 013

051 029U11104-28-2 PCB-1221 029

051 012U11141-16-5 PCB-1232 012

051 012U53469-21-9 PCB-1242 012

051 024U12672-29-6 PCB-1248 024

051 017U11097-69-1 PCB-1254 017

051 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

82 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 154 of 323

Data File vr479505d Report Date 09-Oct-2012 0303

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479505dLab Smp Id 460-45537-E-1-B Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0029 Operator Inst ID PESTGC9iSmp Info 460-45537-E-1-BMisc Info 460-45537-E-1-BComment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 35 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 98000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 38407031 815954 042 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 155 of 323

Data File vr479505d

Date 09-OCT-2012 0029

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-1-B Operator

10162012Page 156 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix vf479506dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1230

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0045

5(mL)

Sample wtvol 990(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

50 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 157 of 323

Data File vf479506d Report Date 09-Oct-2012 0322

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479506dLab Smp Id 460-45537-E-2-A Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0045 Operator Inst ID PESTGC9iSmp Info 460-45537-E-2-AMisc Info 460-45537-E-2-AComment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 36 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 99000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11487 11515 -0028 13346591 501821 025 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 158 of 323

Data File vf479506d

Date 09-OCT-2012 0045

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-2-A Operator

10162012Page 159 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix vr479506dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1230

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0045

5(mL)

Sample wtvol 990(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

051 013U12674-11-2 PCB-1016 013

051 028U11104-28-2 PCB-1221 028

051 012U11141-16-5 PCB-1232 012

051 012U53469-21-9 PCB-1242 012

051 024U12672-29-6 PCB-1248 024

051 017U11097-69-1 PCB-1254 017

051 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

52 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 160 of 323

Data File vr479506d Page 1 Report Date 09-Oct-2012 0322

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479506dLab Smp Id 460-45537-E-2-A Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0045 Operator Inst ID PESTGC9iSmp Info 460-45537-E-2-AMisc Info 460-45537-E-2-AComment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 36 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 99000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 24675227 524223 026 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 161 of 323

Data File vr479506d

Date 09-OCT-2012 0045

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-2-A Operator

10162012Page 162 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vf479200dLevel 2 IC 460-1299268 vf479201dLevel 3 IC 460-1299269 vf479202dLevel 4 IC 460-12992610 vf479203dLevel 5 IC 460-12992611 vf479204d

ANALYTE LVL 1 LVL 2 LVL 3 LVL 4 LVL 5 AVG RTRT WINDOW

PCB-1016 Peak 1 29602891 - 30312960 2960 2961 2959 2959PCB-1016 Peak 2 36403571 - 37113640 3640 3641 3639 3640PCB-1016 Peak 3 40844015 - 41554084 4084 4085 4083 4083PCB-1016 Peak 4 44774409 - 45494477 4477 4479 4477 4476PCB-1016 Peak 5 47224652 - 47924722 4722 4722 4722 4722PCB-1016 Peak 6 51575088 - 52285157 5158 5158 5157 5157PCB-1016 Peak 7 55425472 - 56125542 5543 5542 5542 5542PCB-1016 Peak 8 57515682 - 58225751 5751 5752 5751 5751PCB-1260 Peak 1 77567686 - 78267756 7756 7756 7756 7755PCB-1260 Peak 2 82158145 - 82858216 8215 8215 8215 8215PCB-1260 Peak 3 90839014 - 91549084 9084 9084 9083 9082PCB-1260 Peak 4 93329262 - 94029332 9332 9332 9332 9331PCB-1260 Peak 5 94549384 - 95249454 9454 9454 9454 9453PCB-1260 Peak 6 99019831 - 99719901 9901 9901 9901 9901PCB-1260 Peak 7 1061710546 - 1068610617 10617 10616 10617 10616PCB-1260 Peak 8 1108611016 - 1115611087 11087 11086 11084 11085DCB Decachlorobiphenyl 1151511415 - 1161511518 11520 11515 11510 11512

FORM VI 8082 10162012Page 163 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1299267 vf479200d2Level IC 460-1299268 vf479201d3Level IC 460-1299269 vf479202d4Level IC 460-12992610 vf479203d5Level IC 460-12992611 vf479204d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1016 Peak 1 Ave 155 20012858 10484 96475 9762186122

102726535

PCB-1016 Peak 2 Ave 122 20025248 21181 20808 2014318185

211130015

PCB-1016 Peak 3 Ave 124 20010359 90007 83526 8441074163

871400841

PCB-1016 Peak 4 Ave 130 20045579 38951 35291 3591632814

377100165

PCB-1016 Peak 5 Ave 129 20019485 17677 14821 1595214340

164548979

PCB-1016 Peak 6 Ave 171 20012410 10306 89543 9039281426

977025128

PCB-1016 Peak 7 Ave 161 20015097 12427 11165 1121510046

119900052

PCB-1016 Peak 8 Ave 121 20014456 12522 11609 1161310532

121463746

PCB-1260 Peak 1 Ave 165 20028165 22320 20852 2059718598

221063931

PCB-1260 Peak 2 Ave 173 20032398 25230 23518 2315121164

250922627

PCB-1260 Peak 3 Ave 101 20042792 37584 35706 3549332757

368665853

PCB-1260 Peak 4 Ave 114 20019125 16727 15681 1547514194

162405856

PCB-1260 Peak 5 Ave 71 20097407 90339 86445 8609680436

881445133

PCB-1260 Peak 6 Ave 116 20020218 16837 16387 1620514980

169255417

PCB-1260 Peak 7 Ave 115 20025044 20516 20530 2080218426

210635761

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 164 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1260 Peak 8 Ave 114 20092729 80982 75320 7482969000

785718832

DCB Decachlorobiphenyl Ave 104 200306013 281530 257456 246481238335

265963086

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 165 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vf479200dLevel 2 IC 460-1299268 vf479201dLevel 3 IC 460-1299269 vf479202dLevel 4 IC 460-12992610 vf479203dLevel 5 IC 460-12992611 vf479204d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1LVL 2 LVL 2LVL 3 LVL 3LVL 4 LVL 4LVL 5 LVL 5

PCB-1016 Peak 1 Ave 1285777 5241842 9647477 14643185 21530533 100 500 1000 1500 2500PCB-1016 Peak 2 Ave 2524804 10590544 20808307 30213965 45462323 100 500 1000 1500 2500PCB-1016 Peak 3 Ave 1035943 4500373 8352607 12661468 18540701 100 500 1000 1500 2500PCB-1016 Peak 4 Ave 4557926 19475271 35290615 53874092 82034010 100 500 1000 1500 2500PCB-1016 Peak 5 Ave 1948484 8838480 14821328 23927783 35848765 100 500 1000 1500 2500PCB-1016 Peak 6 Ave 1240957 5152808 8954270 13558761 20356566 100 500 1000 1500 2500PCB-1016 Peak 7 Ave 1509707 6213265 11165134 16822458 25115800 100 500 1000 1500 2500PCB-1016 Peak 8 Ave 1445572 6260864 11609452 17418946 26330856 100 500 1000 1500 2500PCB-1260 Peak 1 Ave 2816529 11159859 20851674 30895442 46495806 100 500 1000 1500 2500PCB-1260 Peak 2 Ave 3239811 12615093 23518487 34726449 52908911 100 500 1000 1500 2500PCB-1260 Peak 3 Ave 4279245 18792136 35705636 53240044 81893015 100 500 1000 1500 2500PCB-1260 Peak 4 Ave 1912505 8363664 15681452 23213228 35484032 100 500 1000 1500 2500PCB-1260 Peak 5 Ave 974074 4516956 8644462 12914338 20108960 100 500 1000 1500 2500PCB-1260 Peak 6 Ave 2021814 8418625 16386843 24307809 37450674 100 500 1000 1500 2500PCB-1260 Peak 7 Ave 2504445 10257895 20530020 31202581 46064749 100 500 1000 1500 2500PCB-1260 Peak 8 Ave 927285 4049088 7531982 11224374 17250044 100 500 1000 1500 2500DCB Decachlorobiphenyl Ave 7650320 14076513 25745578 36972164 47667099 250 500 100 150 200

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 166 of 323

Data File vf479200d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479200dLab Smp Id IC-SG1660L1_00013 Inj Date 30-SEP-2012 1704 Operator Inst ID PESTGC9iSmp Info ic-SG1660L1_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1704 Cal File vf479200dAls bottle 7 Calibration Sample Level 1Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2960 2961 -0001 1285777 100000 120 8000- 12000 10000

3640 3641 -0001 2524804 100000 120 15709- 23564 19636

4084 4085 -0001 1035943 100000 120 6446- 9668 8057

4477 4479 -0002 4557926 100000 120 28359- 42539 35449

4722 4722 0000 1948484 100000 120 12123- 18185 15154

5157 5158 -0001 1240957 100000 130 7721- 11582 9651

5542 5542 0000 1509707 100000 120 9393- 14090 11742

5751 5752 -0001 1445572 100000 120 8994- 13491 11243

Average of Peak Amounts = 122

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 2816529 100000 130 8000- 12000 10000(M)

10162012Page 167 of 323

Data File vf479200d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8216 8215 0001 3239811 100000 130 9202- 13803 11503

9084 9084 0000 4279245 100000 120 12155- 18232 15193

9332 9332 0000 1912505 100000 120 5432- 8148 6790

9454 9454 0000 974074 100000 110 2767- 4150 3458

9901 9901 0000 2021814 100000 120 5743- 8614 7178

10617 10616 0001 2504445 100000 120 7114- 10670 8892

11087 11086 0001 927285 100000 120 2634- 3951 3292

Average of Peak Amounts = 120

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11518 11515 0003 7650320 250000 29 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 168 of 323

Data File vf479200d

Date 30-SEP-2012 1704

Client ID Instrument PESTGC9i

Sample Info ic-SG1660L1_00013 Operator

10162012Page 169 of 323

Data File vf479201d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479201dLab Smp Id IC-SG1660L2_00013 Inj Date 30-SEP-2012 1720 Operator Inst ID PESTGC9iSmp Info SG1660L2_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1720 Cal File vf479201dAls bottle 8 Calibration Sample Level 2Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2960 2961 -0001 5241842 500000 510 8000- 12000 10000

3640 3641 -0001 10590544 500000 500 16163- 24245 20204

4084 4085 -0001 4500373 500000 520 6868- 10303 8585

4477 4479 -0002 19475271 500000 520 29723- 44584 37153

4722 4722 0000 8838480 500000 540 13489- 20234 16861

5158 5158 0000 5152808 500000 530 7864- 11796 9830

5543 5542 0001 6213265 500000 520 9483- 14224 11853

5751 5752 -0001 6260864 500000 520 9555- 14333 11944

Average of Peak Amounts = 518

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 11159859 500000 500 8000- 12000 10000(M)

10162012Page 170 of 323

Data File vf479201d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 12615093 500000 500 9043- 13565 11304

9084 9084 0000 18792136 500000 510 13471- 20207 16839

9332 9332 0000 8363664 500000 510 5996- 8993 7494

9454 9454 0000 4516956 500000 510 3238- 4857 4048

9901 9901 0000 8418625 500000 500 6035- 9052 7544

10617 10616 0001 10257895 500000 490 7353- 11030 9192

11087 11086 0001 4049088 500000 520 2903- 4354 3628

Average of Peak Amounts = 506

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11520 11515 0005 14076513 500000 53 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 171 of 323

Data File vf479201d

Date 30-SEP-2012 1720

Client ID Instrument PESTGC9i

Sample Info SG1660L2_00013 Operator

10162012Page 172 of 323

Data File vf479202d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479202dLab Smp Id IC-SG1660L3_00019 Inj Date 30-SEP-2012 1735 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 9 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2961 2961 0000 9647477 100000 940 8000- 12000 10000

3641 3641 0000 20808307 100000 980 17255- 25882 21569

4085 4085 0000 8352607 100000 960 6926- 10389 8658

4479 4479 0000 35290615 100000 940 29264- 43896 36580

4722 4722 0000 14821328 100000 900 12290- 18435 15363

5158 5158 0000 8954270 100000 920 7425- 11138 9281

5542 5542 0000 11165134 100000 930 9258- 13888 11573

5752 5752 0000 11609452 100000 960 9627- 14440 12034

Average of Peak Amounts = 940

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 20851674 100000 940 8000- 12000 10000(M)

10162012Page 173 of 323

Data File vf479202d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 23518487 100000 940 9023- 13535 11279

9084 9084 0000 35705636 100000 970 13699- 20548 17124

9332 9332 0000 15681452 100000 960 6016- 9025 7520

9454 9454 0000 8644462 100000 980 3317- 4975 4146

9901 9901 0000 16386843 100000 970 6287- 9431 7859

10616 10616 0000 20530020 100000 970 7877- 11815 9846

11086 11086 0000 7531982 100000 960 2890- 4335 3612

Average of Peak Amounts = 962

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11515 11515 0000 25745578 100000 97 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 174 of 323

Data File vf479202d

Date 30-SEP-2012 1735

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 175 of 323

Data File vf479203d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479203dLab Smp Id IC-SG1660L4_00013 Inj Date 30-SEP-2012 1751 Operator Inst ID PESTGC9iSmp Info SG1660L4_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1751 Cal File vf479203dAls bottle 10 Calibration Sample Level 4Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2959 2961 -0002 14643185 150000 1400 8000- 12000 10000

3639 3641 -0002 30213965 150000 1400 16507- 24760 20633

4083 4085 -0002 12661468 150000 1400 6917- 10376 8647

4477 4479 -0002 53874092 150000 1400 29433- 44149 36791

4722 4722 0000 23927783 150000 1400 13072- 19609 16341

5157 5158 -0001 13558761 150000 1400 7408- 11111 9259

5542 5542 0000 16822458 150000 1400 9191- 13786 11488

5751 5752 -0001 17418946 150000 1400 9516- 14275 11896

Average of Peak Amounts = 143e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 30895442 150000 1400 8000- 12000 10000(M)

10162012Page 176 of 323

Data File vf479203d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 34726449 150000 1400 8992- 13488 11240

9083 9084 -0001 53240044 150000 1400 13786- 20679 17232

9332 9332 0000 23213228 150000 1400 6011- 9016 7513

9454 9454 0000 12914338 150000 1500 3344- 5016 4180

9901 9901 0000 24307809 150000 1400 6294- 9441 7868

10617 10616 0001 31202581 150000 1500 8080- 12119 10099

11084 11086 -0002 11224374 150000 1400 2906- 4360 3633

Average of Peak Amounts = 143e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11510 11515 -0005 36972164 150000 140 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 177 of 323

Data File vf479203d

Date 30-SEP-2012 1751

Client ID Instrument PESTGC9i

Sample Info SG1660L4_00013 Operator

10162012Page 178 of 323

Data File vf479204d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479204dLab Smp Id IC-SG1660L5_00013 Inj Date 30-SEP-2012 1807 Operator Inst ID PESTGC9iSmp Info SG1660L5_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1807 Cal File vf479204dAls bottle 11 Calibration Sample Level 5Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2959 2961 -0002 21530533 250000 2100 8000- 12000 10000

3640 3641 -0001 45462323 250000 2200 16892- 25338 21115

4083 4085 -0002 18540701 250000 2100 6889- 10334 8611

4476 4479 -0003 82034010 250000 2200 30481- 45721 38101

4722 4722 0000 35848765 250000 2200 13320- 19980 16650

5157 5158 -0001 20356566 250000 2100 7564- 11346 9455

5542 5542 0000 25115800 250000 2100 9332- 13998 11665

5751 5752 -0001 26330856 250000 2200 9784- 14675 12230

Average of Peak Amounts = 213e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7755 7756 -0001 46495806 250000 2100 8000- 12000 10000(M)

10162012Page 179 of 323

Data File vf479204d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 52908911 250000 2100 9103- 13655 11379

9082 9084 -0002 81893015 250000 2200 14090- 21136 17613

9331 9332 -0001 35484032 250000 2200 6105- 9158 7632

9453 9454 -0001 20108960 250000 2300 3460- 5190 4325

9901 9901 0000 37450674 250000 2200 6444- 9666 8055

10616 10616 0000 46064749 250000 2200 7926- 11889 9907

11085 11086 -0001 17250044 250000 2200 2968- 4452 3710

Average of Peak Amounts = 219e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11512 11515 -0003 47667099 200000 180 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 180 of 323

Data File vf479204d

Date 30-SEP-2012 1807

Client ID Instrument PESTGC9i

Sample Info SG1660L5_00013 Operator

10162012Page 181 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vr479200dLevel 2 IC 460-1299268 vr479201dLevel 3 IC 460-1299269 vr479202dLevel 4 IC 460-12992610 vr479203dLevel 5 IC 460-12992611 vr479204d

ANALYTE LVL 1 LVL 2 LVL 3 LVL 4 LVL 5 AVG RTRT WINDOW

PCB-1016 Peak 1 20842015 - 21552085 2084 2085 2083 2084PCB-1016 Peak 2 25272457 - 25972527 2526 2527 2527 2526PCB-1016 Peak 3 27762707 - 28472777 2776 2777 2775 2775PCB-1016 Peak 4 31283060 - 32003128 3128 3130 3128 3127PCB-1016 Peak 5 33293260 - 34003329 3329 3330 3328 3328PCB-1016 Peak 6 36823615 - 37553682 3682 3685 3683 3681PCB-1016 Peak 7 40433973 - 41134042 4043 4043 4042 4043PCB-1016 Peak 8 41904121 - 42614190 4190 4191 4188 4190PCB-1260 Peak 1 60716002 - 61426072 6072 6072 6071 6071PCB-1260 Peak 2 65226452 - 65926522 6523 6522 6522 6521PCB-1260 Peak 3 69646894 - 70346964 6965 6964 6963 6964PCB-1260 Peak 4 71647095 - 72357165 7165 7165 7164 7164PCB-1260 Peak 5 76027532 - 76727602 7603 7602 7602 7601PCB-1260 Peak 6 88938823 - 89638893 8894 8893 8893 8892PCB-1260 Peak 7 91159045 - 91859115 9115 9115 9115 9114PCB-1260 Peak 8 1015310083 - 1022310153 10154 10153 10153 10153DCB Decachlorobiphenyl 1062410524 - 1072410625 10625 10624 10624 10624

FORM VI 8082 10162012Page 182 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1299267 vr479200d2Level IC 460-1299268 vr479201d3Level IC 460-1299269 vr479202d4Level IC 460-12992610 vr479203d5Level IC 460-12992611 vr479204d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1016 Peak 1 Ave 197 20021391 15827 14690 1421213626

159493236

PCB-1016 Peak 2 Ave 165 20034434 28377 25503 2514722693

272309984

PCB-1016 Peak 3 Ave 77 20020149 18502 16986 1713716990

179529604

PCB-1016 Peak 4 Ave 163 20075334 61344 55787 5498850020

594947119

PCB-1016 Peak 5 Ave 111 20026774 23733 21963 2197020028

228936643

PCB-1016 Peak 6 Ave 186 20030865 24479 22517 2109919526

236972316

PCB-1016 Peak 7 Ave 97 20025842 23012 21540 2153920131

224127747

PCB-1016 Peak 8 Ave 151 20012619 94689 86303 1057294995

101578271

PCB-1260 Peak 1 Ave 163 20041532 33110 31025 3015327565

326771001

PCB-1260 Peak 2 Ave 177 20078411 60909 57128 5539650491

604671657

PCB-1260 Peak 3 Ave 138 20068452 55082 53236 5187948612

554520757

PCB-1260 Peak 4 Ave 154 20037971 30462 28586 2772626073

301638112

PCB-1260 Peak 5 Ave 148 20034082 26592 25567 2477624302

270637128

PCB-1260 Peak 6 Ave 81 20038982 34673 33173 3331131697

343672090

PCB-1260 Peak 7 Ave 66 20023297 21847 20031 2012320512

211620048

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 183 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1260 Peak 8 Ave 59 20018824 17382 16914 1709216013

172450198

DCB Decachlorobiphenyl Ave 109 200544588 499440 455074 438703415700

470701073

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 184 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vr479200dLevel 2 IC 460-1299268 vr479201dLevel 3 IC 460-1299269 vr479202dLevel 4 IC 460-12992610 vr479203dLevel 5 IC 460-12992611 vr479204d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1LVL 2 LVL 2LVL 3 LVL 3LVL 4 LVL 4LVL 5 LVL 5

PCB-1016 Peak 1 Ave 2139086 7913738 14690255 21317999 34065069 100 500 1000 1500 2500PCB-1016 Peak 2 Ave 3443416 14188692 25503333 37720095 56733462 100 500 1000 1500 2500PCB-1016 Peak 3 Ave 2014938 9251204 16986172 25705034 42475382 100 500 1000 1500 2500PCB-1016 Peak 4 Ave 7533379 30672168 55786970 82482485 125050351 100 500 1000 1500 2500PCB-1016 Peak 5 Ave 2677413 11866731 21962918 32955239 50069130 100 500 1000 1500 2500PCB-1016 Peak 6 Ave 3086462 12239557 22517485 31648230 48815297 100 500 1000 1500 2500PCB-1016 Peak 7 Ave 2584175 11505820 21540272 32309208 50326849 100 500 1000 1500 2500PCB-1016 Peak 8 Ave 1261883 4734436 8630325 15857466 23748661 100 500 1000 1500 2500PCB-1260 Peak 1 Ave 4153239 16554914 31025367 45229464 68912349 100 500 1000 1500 2500PCB-1260 Peak 2 Ave 7841143 30454619 57128111 83094008 126227611 100 500 1000 1500 2500PCB-1260 Peak 3 Ave 6845178 27541094 53235986 77818190 121529078 100 500 1000 1500 2500PCB-1260 Peak 4 Ave 3797116 15230911 28586487 41589423 65183263 100 500 1000 1500 2500PCB-1260 Peak 5 Ave 3408191 13295973 25567248 37163734 60754093 100 500 1000 1500 2500PCB-1260 Peak 6 Ave 3898216 17336408 33172625 49966572 79243490 100 500 1000 1500 2500PCB-1260 Peak 7 Ave 2329661 10923449 20031237 30184937 51279969 100 500 1000 1500 2500PCB-1260 Peak 8 Ave 1882356 8691093 16914378 25637846 40032694 100 500 1000 1500 2500DCB Decachlorobiphenyl Ave 13614701 24972013 45507407 65805444 83140007 250 500 100 150 200

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 185 of 323

Data File vr479200d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479200dLab Smp Id IC-SG1660L1_00013 Inj Date 30-SEP-2012 1704 Operator Inst ID PESTGC9iSmp Info ic-SG1660L1_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 7 Calibration Sample Level 1Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2085 2085 0000 2139086 100000 130 8000- 12000 10000(M)

2527 2527 0000 3443416 100000 130 13324- 19985 16098

2777 2777 0000 2014938 100000 110 9975- 14963 9420

3128 3130 -0002 7533379 100000 130 29367- 44051 35218

3329 3330 -0001 2677413 100000 120 11758- 17638 12517

3682 3685 -0003 3086462 100000 130 11464- 17196 14429

4042 4043 -0001 2584175 100000 120 11819- 17728 12081

4190 4191 -0001 1261883 100000 120 5577- 8366 5899

Average of Peak Amounts = 123

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 4153239 100000 130 8000- 12000 10000

10162012Page 186 of 323

Data File vr479200d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 7841143 100000 130 14654- 21981 18880

6964 6964 0000 6845178 100000 120 14108- 21162 16482

7165 7165 0000 3797116 100000 120 7567- 11351 9143

7602 7602 0000 3408191 100000 120 7053- 10579 8206

8893 8893 0000 3898216 100000 110 9199- 13799 9386

9115 9115 0000 2329661 100000 110 5953- 8930 5609

10153 10153 0000 1882356 100000 110 4647- 6971 4532

Average of Peak Amounts = 121

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10625 10624 0001 13614701 250000 29 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 187 of 323

Data File vr479200d

Date 30-SEP-2012 1704

Client ID Instrument PESTGC9i

Sample Info ic-SG1660L1_00013 Operator

10162012Page 188 of 323

Data File vr479201d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479201dLab Smp Id IC-SG1660L2_00013 Inj Date 30-SEP-2012 1720 Operator Inst ID PESTGC9iSmp Info SG1660L2_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 8 Calibration Sample Level 2Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2084 2085 -0001 7913738 500000 500 8000- 12000 10000(M)

2526 2527 -0001 14188692 500000 520 13324- 19985 17929

2776 2777 -0001 9251204 500000 520 9975- 14963 11690

3128 3130 -0002 30672168 500000 520 29367- 44051 38758

3329 3330 -0001 11866731 500000 520 11758- 17638 14995

3682 3685 -0003 12239557 500000 520 11464- 17196 15466

4043 4043 0000 11505820 500000 510 11819- 17728 14539

4190 4191 -0001 4734436 500000 470 5577- 8366 5983

Average of Peak Amounts = 508

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 16554914 500000 510 8000- 12000 10000

10162012Page 189 of 323

Data File vr479201d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6523 6522 0001 30454619 500000 500 14654- 21981 18396

6965 6964 0001 27541094 500000 500 14108- 21162 16636

7165 7165 0000 15230911 500000 500 7567- 11351 9200

7603 7602 0001 13295973 500000 490 7053- 10579 8031

8894 8893 0001 17336408 500000 500 9199- 13799 10472

9115 9115 0000 10923449 500000 520 5953- 8930 6598

10154 10153 0001 8691093 500000 500 4647- 6971 5250

Average of Peak Amounts = 503

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10625 10624 0001 24972013 500000 53 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 190 of 323

Data File vr479201d

Date 30-SEP-2012 1720

Client ID Instrument PESTGC9i

Sample Info SG1660L2_00013 Operator

10162012Page 191 of 323

Data File vr479202d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479202dLab Smp Id IC-SG1660L3_00019 Inj Date 30-SEP-2012 1735 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 9 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2085 2085 0000 14690255 100000 920 8000- 12000 10000(M)

2527 2527 0000 25503333 100000 940 13324- 19985 17361

2777 2777 0000 16986172 100000 950 9975- 14963 11563

3130 3130 0000 55786970 100000 940 29367- 44051 37975

3330 3330 0000 21962918 100000 960 11758- 17638 14951

3685 3685 0000 22517485 100000 950 11464- 17196 15328

4043 4043 0000 21540272 100000 960 11819- 17728 14663

4191 4191 0000 8630325 100000 850 5577- 8366 5875

Average of Peak Amounts = 933

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 31025367 100000 950 8000- 12000 10000

10162012Page 192 of 323

Data File vr479202d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 57128111 100000 940 14654- 21981 18413

6964 6964 0000 53235986 100000 960 14108- 21162 17159

7165 7165 0000 28586487 100000 950 7567- 11351 9214

7602 7602 0000 25567248 100000 940 7053- 10579 8241

8893 8893 0000 33172625 100000 960 9199- 13799 10692

9115 9115 0000 20031237 100000 950 5953- 8930 6456

10153 10153 0000 16914378 100000 980 4647- 6971 5452

Average of Peak Amounts = 955

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 45507407 100000 97 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 193 of 323

Data File vr479202d

Date 30-SEP-2012 1735

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 194 of 323

Data File vr479203d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479203dLab Smp Id IC-SG1660L4_00013 Inj Date 30-SEP-2012 1751 Operator Inst ID PESTGC9iSmp Info SG1660L4_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 10 Calibration Sample Level 4Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2083 2085 -0002 21317999 150000 1300 8000- 12000 10000(M)

2527 2527 0000 37720095 150000 1400 13324- 19985 17694

2775 2777 -0002 25705034 150000 1400 9975- 14963 12058

3128 3130 -0002 82482485 150000 1400 29367- 44051 38691

3328 3330 -0002 32955239 150000 1400 11758- 17638 15459

3683 3685 -0002 31648230 150000 1300 11464- 17196 14846

4042 4043 -0001 32309208 150000 1400 11819- 17728 15156

4188 4191 -0003 15857466 150000 1600 5577- 8366 7439

Average of Peak Amounts = 141e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6071 6072 -0001 45229464 150000 1400 8000- 12000 10000

10162012Page 195 of 323

Data File vr479203d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 83094008 150000 1400 14654- 21981 18372

6963 6964 -0001 77818190 150000 1400 14108- 21162 17205

7164 7165 -0001 41589423 150000 1400 7567- 11351 9195

7602 7602 0000 37163734 150000 1400 7053- 10579 8217

8893 8893 0000 49966572 150000 1400 9199- 13799 11047

9115 9115 0000 30184937 150000 1400 5953- 8930 6674

10153 10153 0000 25637846 150000 1500 4647- 6971 5668

Average of Peak Amounts = 141e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 65805444 150000 140 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 196 of 323

Data File vr479203d

Date 30-SEP-2012 1751

Client ID Instrument PESTGC9i

Sample Info SG1660L4_00013 Operator

10162012Page 197 of 323

Data File vr479204d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479204dLab Smp Id IC-SG1660L5_00013 Inj Date 30-SEP-2012 1807 Operator Inst ID PESTGC9iSmp Info SG1660L5_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 11 Calibration Sample Level 5Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2084 2085 -0001 34065069 250000 2100 8000- 12000 10000(M)

2526 2527 -0001 56733462 250000 2100 13324- 19985 16654

2775 2777 -0002 42475382 250000 2400 9975- 14963 12469

3127 3130 -0003 125050351 250000 2100 29367- 44051 36709

3328 3330 -0002 50069130 250000 2200 11758- 17638 14698

3681 3685 -0004 48815297 250000 2000 11464- 17196 14330

4043 4043 0000 50326849 250000 2200 11819- 17728 14774

4190 4191 -0001 23748661 250000 2300 5577- 8366 6972

Average of Peak Amounts = 219e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6071 6072 -0001 68912349 250000 2100 8000- 12000 10000

10162012Page 198 of 323

Data File vr479204d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6521 6522 -0001 126227611 250000 2100 14654- 21981 18317

6964 6964 0000 121529078 250000 2200 14108- 21162 17635

7164 7165 -0001 65183263 250000 2200 7567- 11351 9459

7601 7602 -0001 60754093 250000 2200 7053- 10579 8816

8892 8893 -0001 79243490 250000 2300 9199- 13799 11499

9114 9115 -0001 51279969 250000 2400 5953- 8930 7441

10153 10153 0000 40032694 250000 2300 4647- 6971 5809

Average of Peak Amounts = 223e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 83140007 200000 180 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 199 of 323

Data File vr479204d

Date 30-SEP-2012 1807

Client ID Instrument PESTGC9i

Sample Info SG1660L5_00013 Operator

10162012Page 200 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vf479205d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1221 Peak 1 16651595 - 17351665PCB-1221 Peak 2 21352065 - 22052135PCB-1221 Peak 3 26722602 - 27422672PCB-1221 Peak 4 28732803 - 29432873PCB-1221 Peak 5 29612891 - 30312961PCB-1221 Peak 6 37393669 - 38093739PCB-1221 Peak 7 40834013 - 41534083PCB-1221 Peak 8 44774407 - 45474477

FORM VI 8082 10162012Page 201 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992612 vf479205d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

47106PCB-1221 Peak 1 Ave 20047106130012961PCB-1221 Peak 2 Ave 20012960750058524PCB-1221 Peak 3 Ave 20058523710040015PCB-1221 Peak 4 Ave 20040015420013789PCB-1221 Peak 5 Ave 20013788908018488PCB-1221 Peak 6 Ave 20018488040061501PCB-1221 Peak 7 Ave 20061500800024165PCB-1221 Peak 8 Ave 200241652800

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 202 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vf479205d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1221 Peak 1 Ave 4710613 1000PCB-1221 Peak 2 Ave 1296075 1000PCB-1221 Peak 3 Ave 5852371 1000PCB-1221 Peak 4 Ave 4001542 1000PCB-1221 Peak 5 Ave 13788908 1000PCB-1221 Peak 6 Ave 1848804 1000PCB-1221 Peak 7 Ave 615008 1000PCB-1221 Peak 8 Ave 2416528 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 203 of 323

Data File vf479205d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479205dLab Smp Id IC-SG1221L3_00014 Inj Date 30-SEP-2012 1822 Operator Inst ID PESTGC9iSmp Info ic SG1221L3_00014Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 12 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12210subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

22 Aroclor-1221 CAS 11104-28-2

1665 1665 0000 4710613 100000 1000 8000- 12000 10000

2135 2135 0000 1296075 100000 1000 2201- 3302 2751

2672 2672 0000 5852371 100000 1000 9939- 14909 12424

2873 2873 0000 4001542 100000 1000 6796- 10194 8495

2961 2961 0000 13788908 100000 1000 23418- 35126 29272

3739 3739 0000 1848804 100000 1000 3140- 4710 3925

4083 4083 0000 615008 100000 1000 1044- 1567 1306

4477 4477 0000 2416528 100000 1000 4104- 6156 5130

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 204 of 323

Data File vf479205d

Date 30-SEP-2012 1822

Client ID Instrument PESTGC9i

Sample Info ic SG1221L3_00014 Operator

10162012Page 205 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vr479205d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1221 Peak 1 11111041 - 11811111PCB-1221 Peak 2 15111441 - 15811511PCB-1221 Peak 3 18601790 - 19301860PCB-1221 Peak 4 20822012 - 21522082PCB-1221 Peak 5 25282458 - 25982528PCB-1221 Peak 6 26022532 - 26722602PCB-1221 Peak 7 26852615 - 27552685PCB-1221 Peak 8 31303060 - 32003130

FORM VI 8082 10162012Page 206 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992612 vr479205d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

64024PCB-1221 Peak 1 Ave 20064024020030571PCB-1221 Peak 2 Ave 20030571000095270PCB-1221 Peak 3 Ave 20095269770024981PCB-1221 Peak 4 Ave 20024981158027336PCB-1221 Peak 5 Ave 20027336400022123PCB-1221 Peak 6 Ave 20022122590041633PCB-1221 Peak 7 Ave 20041632790048909PCB-1221 Peak 8 Ave 200489094700

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 207 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vr479205d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1221 Peak 1 Ave 6402402 1000PCB-1221 Peak 2 Ave 3057100 1000PCB-1221 Peak 3 Ave 9526977 1000PCB-1221 Peak 4 Ave 24981158 1000PCB-1221 Peak 5 Ave 2733640 1000PCB-1221 Peak 6 Ave 2212259 1000PCB-1221 Peak 7 Ave 4163279 1000PCB-1221 Peak 8 Ave 4890947 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 208 of 323

Data File vr479205d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479205dLab Smp Id IC-SG1221L3_00014 Inj Date 30-SEP-2012 1822 Operator Inst ID PESTGC9iSmp Info ic SG1221L3_00014Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 12 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12210subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

22 Aroclor-1221 CAS 11104-28-2

1111 1111 0000 6402402 100000 1000 8000- 12000 10000(M)

1511 1511 0000 3057100 100000 1000 3820- 5730 4775

1860 1860 0000 9526977 100000 1000 11904- 17856 14880

2082 2082 0000 24981158 100000 1000 31215- 46822 39018

2528 2528 0000 2733640 100000 1000 3416- 5124 4270

2602 2602 0000 2212259 100000 1000 2764- 4146 3455

2685 2685 0000 4163279 100000 1000 5202- 7803 6503

3130 3130 0000 4890947 100000 1000 6111- 9167 7639

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 209 of 323

Data File vr479205d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 210 of 323

Data File vr479205d

Date 30-SEP-2012 1822

Client ID Instrument PESTGC9i

Sample Info ic SG1221L3_00014 Operator

10162012Page 211 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vf479206d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1232 Peak 1 29612891 - 30312961PCB-1232 Peak 2 36403570 - 37103640PCB-1232 Peak 3 40854015 - 41554085PCB-1232 Peak 4 47224652 - 47924722PCB-1232 Peak 5 49024832 - 49724902PCB-1232 Peak 6 50875017 - 51575087PCB-1232 Peak 7 55425472 - 56125542PCB-1232 Peak 8 57515681 - 58215751

FORM VI 8082 10162012Page 212 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992613 vf479206d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

97711PCB-1232 Peak 1 Ave 20097710620094688PCB-1232 Peak 2 Ave 20094688030035761PCB-1232 Peak 3 Ave 20035761260066995PCB-1232 Peak 4 Ave 20066994820050607PCB-1232 Peak 5 Ave 20050607280041053PCB-1232 Peak 6 Ave 20041053380057396PCB-1232 Peak 7 Ave 20057395890062677PCB-1232 Peak 8 Ave 200626765000

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 213 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vf479206d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1232 Peak 1 Ave 9771062 1000PCB-1232 Peak 2 Ave 9468803 1000PCB-1232 Peak 3 Ave 3576126 1000PCB-1232 Peak 4 Ave 6699482 1000PCB-1232 Peak 5 Ave 5060728 1000PCB-1232 Peak 6 Ave 4105338 1000PCB-1232 Peak 7 Ave 5739589 1000PCB-1232 Peak 8 Ave 6267650 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 214 of 323

Data File vf479206d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479206dLab Smp Id ic SG1232L3_00013 Inj Date 30-SEP-2012 1838 Operator Inst ID PESTGC9iSmp Info ic SG1232L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 13 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12320subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

23 Aroclor-1232 CAS 11141-16-5

2961 2961 0000 9771062 100000 1000 8000- 12000 10000

3640 3640 0000 9468803 100000 1000 7753- 11629 9691

4085 4085 0000 3576126 100000 1000 2928- 4392 3660

4722 4722 0000 6699482 100000 1000 5485- 8228 6856

4902 4902 0000 5060728 100000 1000 4143- 6215 5179

5087 5087 0000 4105338 100000 1000 3361- 5042 4202

5542 5542 0000 5739589 100000 1000 4699- 7049 5874

5751 5751 0000 6267650 100000 1000 5132- 7697 6415

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 215 of 323

Data File vf479206d

Date 30-SEP-2012 1838

Client ID Instrument PESTGC9i

Sample Info ic SG1232L3_00013 Operator

10162012Page 216 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vr479206d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1232 Peak 1 20822012 - 21522082PCB-1232 Peak 2 25262456 - 25962526PCB-1232 Peak 3 27762706 - 28462776PCB-1232 Peak 4 31283058 - 31983128PCB-1232 Peak 5 33293259 - 33993329PCB-1232 Peak 6 34243354 - 34943424PCB-1232 Peak 7 40423972 - 41124042PCB-1232 Peak 8 46144544 - 46844614

FORM VI 8082 10162012Page 217 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992613 vr479206d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

18402PCB-1232 Peak 1 Ave 20018402354014182PCB-1232 Peak 2 Ave 20014181613010089PCB-1232 Peak 3 Ave 20010089309027669PCB-1232 Peak 4 Ave 20027669356010841PCB-1232 Peak 5 Ave 20010840936085833PCB-1232 Peak 6 Ave 20085833230011581PCB-1232 Peak 7 Ave 20011580551048393PCB-1232 Peak 8 Ave 200483934800

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 218 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vr479206d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1232 Peak 1 Ave 18402354 1000PCB-1232 Peak 2 Ave 14181613 1000PCB-1232 Peak 3 Ave 10089309 1000PCB-1232 Peak 4 Ave 27669356 1000PCB-1232 Peak 5 Ave 10840936 1000PCB-1232 Peak 6 Ave 8583323 1000PCB-1232 Peak 7 Ave 11580551 1000PCB-1232 Peak 8 Ave 4839348 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 219 of 323

Data File vr479206d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479206dLab Smp Id ic SG1232L3_00013 Inj Date 30-SEP-2012 1838 Operator Inst ID PESTGC9iSmp Info ic SG1232L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 13 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12320subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

23 Aroclor-1232 CAS 11141-16-5

2082 2082 0000 18402354 100000 1000 8000- 12000 10000

2526 2526 0000 14181613 100000 1000 6165- 9248 7706

2776 2776 0000 10089309 100000 1000 4386- 6579 5483

3128 3128 0000 27669356 100000 1000 12029- 18043 15036

3329 3329 0000 10840936 100000 1000 4713- 7069 5891

3424 3424 0000 8583323 100000 1000 3731- 5597 4664

4042 4042 0000 11580551 100000 1000 5034- 7552 6293

4614 4614 0000 4839348 100000 1000 2104- 3156 2630

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 220 of 323

Data File vr479206d

Date 30-SEP-2012 1838

Client ID Instrument PESTGC9i

Sample Info ic SG1232L3_00013 Operator

10162012Page 221 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vf479207d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1242 Peak 1 29612891 - 30312961PCB-1242 Peak 2 36413571 - 37113641PCB-1242 Peak 3 40864016 - 41564086PCB-1242 Peak 4 44794409 - 45494479PCB-1242 Peak 5 47234653 - 47934723PCB-1242 Peak 6 51585088 - 52285158PCB-1242 Peak 7 57525682 - 58225752PCB-1242 Peak 8 62656195 - 63356265

FORM VI 8082 10162012Page 222 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992614 vf479207d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

81414PCB-1242 Peak 1 Ave 20081414290015365PCB-1242 Peak 2 Ave 20015365311065982PCB-1242 Peak 3 Ave 20065981950028106PCB-1242 Peak 4 Ave 20028106459012209PCB-1242 Peak 5 Ave 20012208628069961PCB-1242 Peak 6 Ave 20069960990010615PCB-1242 Peak 7 Ave 20010615499010283PCB-1242 Peak 8 Ave 200102828980

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 223 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vf479207d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1242 Peak 1 Ave 8141429 1000PCB-1242 Peak 2 Ave 15365311 1000PCB-1242 Peak 3 Ave 6598195 1000PCB-1242 Peak 4 Ave 28106459 1000PCB-1242 Peak 5 Ave 12208628 1000PCB-1242 Peak 6 Ave 6996099 1000PCB-1242 Peak 7 Ave 10615499 1000PCB-1242 Peak 8 Ave 10282898 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 224 of 323

Data File vf479207d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479207dLab Smp Id ic SG1242L3_00013 Inj Date 30-SEP-2012 1854 Operator Inst ID PESTGC9iSmp Info ic SG1242L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 14 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12420subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

24 Aroclor-1242 CAS 53469-21-9

2961 2961 0000 8141429 100000 1000 8000- 12000 10000(M)

3641 3641 0000 15365311 100000 1000 15098- 22648 18873

4086 4086 0000 6598195 100000 1000 6484- 9725 8104

4479 4479 0000 28106459 100000 1000 27618- 41427 34523

4723 4723 0000 12208628 100000 1000 11997- 17995 14996

5158 5158 0000 6996099 100000 1000 6875- 10312 8593

5752 5752 0000 10615499 100000 1000 10431- 15647 13039

6265 6265 0000 10282898 100000 1000 10104- 15156 12630

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 225 of 323

Data File vf479207d Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 226 of 323

Data File vf479207d

Date 30-SEP-2012 1854

Client ID Instrument PESTGC9i

Sample Info ic SG1242L3_00013 Operator

10162012Page 227 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vr479207d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1242 Peak 1 20832013 - 21532083PCB-1242 Peak 2 25272457 - 25972527PCB-1242 Peak 3 27772707 - 28472777PCB-1242 Peak 4 31293059 - 31993129PCB-1242 Peak 5 33293259 - 33993329PCB-1242 Peak 6 36853615 - 37553685PCB-1242 Peak 7 40443974 - 41144044PCB-1242 Peak 8 51265056 - 51965126

FORM VI 8082 10162012Page 228 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992614 vr479207d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

13527PCB-1242 Peak 1 Ave 20013526845020219PCB-1242 Peak 2 Ave 20020218998014340PCB-1242 Peak 3 Ave 20014339987044262PCB-1242 Peak 4 Ave 20044261735017388PCB-1242 Peak 5 Ave 20017387684018314PCB-1242 Peak 6 Ave 20018314121017750PCB-1242 Peak 7 Ave 20017749733015393PCB-1242 Peak 8 Ave 200153932670

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 229 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vr479207d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1242 Peak 1 Ave 13526845 1000PCB-1242 Peak 2 Ave 20218998 1000PCB-1242 Peak 3 Ave 14339987 1000PCB-1242 Peak 4 Ave 44261735 1000PCB-1242 Peak 5 Ave 17387684 1000PCB-1242 Peak 6 Ave 18314121 1000PCB-1242 Peak 7 Ave 17749733 1000PCB-1242 Peak 8 Ave 15393267 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 230 of 323

Data File vr479207d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479207dLab Smp Id ic SG1242L3_00013 Inj Date 30-SEP-2012 1854 Operator Inst ID PESTGC9iSmp Info ic SG1242L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 14 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12420subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

24 Aroclor-1242 CAS 53469-21-9

2083 2083 0000 13526845 100000 1000 8000- 12000 10000(M)

2527 2527 0000 20218998 100000 1000 11958- 17937 14947

2777 2777 0000 14339987 100000 1000 8481- 12721 10601

3129 3129 0000 44261735 100000 1000 26177- 39266 32721

3329 3329 0000 17387684 100000 1000 10283- 15425 12854

3685 3685 0000 18314121 100000 1000 10831- 16247 13539

4044 4044 0000 17749733 100000 1000 10497- 15746 13122

5126 5126 0000 15393267 100000 1000 9104- 13656 11380

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 231 of 323

Data File vr479207d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 232 of 323

Data File vr479207d

Date 30-SEP-2012 1854

Client ID Instrument PESTGC9i

Sample Info ic SG1242L3_00013 Operator

10162012Page 233 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vf479208d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1248 Peak 1 36373567 - 37073637PCB-1248 Peak 2 44734403 - 45434473PCB-1248 Peak 3 49514881 - 50214951PCB-1248 Peak 4 50865016 - 51565086PCB-1248 Peak 5 55415471 - 56115541PCB-1248 Peak 6 57505680 - 58205750PCB-1248 Peak 7 61916121 - 62616191PCB-1248 Peak 8 62626192 - 63326262

FORM VI 8082 10162012Page 234 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992615 vf479208d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

89356PCB-1248 Peak 1 Ave 20089355610020760PCB-1248 Peak 2 Ave 20020759623031559PCB-1248 Peak 3 Ave 20031559070012341PCB-1248 Peak 4 Ave 20012341389015809PCB-1248 Peak 5 Ave 20015808884017466PCB-1248 Peak 6 Ave 20017465791016624PCB-1248 Peak 7 Ave 20016623508019431PCB-1248 Peak 8 Ave 200194311040

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 235 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vf479208d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1248 Peak 1 Ave 8935561 1000PCB-1248 Peak 2 Ave 20759623 1000PCB-1248 Peak 3 Ave 3155907 1000PCB-1248 Peak 4 Ave 12341389 1000PCB-1248 Peak 5 Ave 15808884 1000PCB-1248 Peak 6 Ave 17465791 1000PCB-1248 Peak 7 Ave 16623508 1000PCB-1248 Peak 8 Ave 19431104 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 236 of 323

Data File vf479208d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479208dLab Smp Id ic SG1248L3_00013 Inj Date 30-SEP-2012 1909 Operator Inst ID PESTGC9iSmp Info ic SG1248L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 15 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12480subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

25 Aroclor-1248 CAS 12672-29-6

3637 3637 0000 8935561 100000 1000 8000- 12000 10000

4473 4473 0000 20759623 100000 1000 18586- 27879 23233

4951 4951 0000 3155907 100000 1000 2825- 4238 3532

5086 5086 0000 12341389 100000 1000 11049- 16574 13812

5541 5541 0000 15808884 100000 1000 14154- 21231 17692

5750 5750 0000 17465791 100000 1000 15637- 23456 19546

6191 6191 0000 16623508 100000 1000 14883- 22325 18604

6262 6262 0000 19431104 100000 1000 17397- 26095 21746

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 237 of 323

Data File vf479208d

Date 30-SEP-2012 1909

Client ID Instrument PESTGC9i

Sample Info ic SG1248L3_00013 Operator

10162012Page 238 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vr479208d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1248 Peak 1 25252455 - 25952525PCB-1248 Peak 2 31243054 - 31943124PCB-1248 Peak 3 34233353 - 34933423PCB-1248 Peak 4 36783608 - 37483678PCB-1248 Peak 5 40413971 - 41114041PCB-1248 Peak 6 41864116 - 42564186PCB-1248 Peak 7 46154545 - 46854615PCB-1248 Peak 8 51245054 - 51945124

FORM VI 8082 10162012Page 239 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992615 vr479208d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

11417PCB-1248 Peak 1 Ave 20011416682034274PCB-1248 Peak 2 Ave 20034273988063635PCB-1248 Peak 3 Ave 20063635020034030PCB-1248 Peak 4 Ave 20034030097030220PCB-1248 Peak 5 Ave 20030220358018203PCB-1248 Peak 6 Ave 20018202681015611PCB-1248 Peak 7 Ave 20015610993034370PCB-1248 Peak 8 Ave 200343696460

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 240 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vr479208d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1248 Peak 1 Ave 11416682 1000PCB-1248 Peak 2 Ave 34273988 1000PCB-1248 Peak 3 Ave 6363502 1000PCB-1248 Peak 4 Ave 34030097 1000PCB-1248 Peak 5 Ave 30220358 1000PCB-1248 Peak 6 Ave 18202681 1000PCB-1248 Peak 7 Ave 15610993 1000PCB-1248 Peak 8 Ave 34369646 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 241 of 323

Data File vr479208d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479208dLab Smp Id ic SG1248L3_00013 Inj Date 30-SEP-2012 1909 Operator Inst ID PESTGC9iSmp Info ic SG1248L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 15 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12480subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

25 Aroclor-1248 CAS 12672-29-6

2525 2525 0000 11416682 100000 1000 8000- 12000 10000(M)

3124 3124 0000 34273988 100000 1000 24017- 36025 30021

3423 3423 0000 6363502 100000 1000 4459- 6689 5574

3678 3678 0000 34030097 100000 1000 23846- 35769 29807

4041 4041 0000 30220358 100000 1000 21176- 31764 26470

4186 4186 0000 18202681 100000 1000 12755- 19133 15944

4615 4615 0000 15610993 100000 1000 10939- 16409 13674

5124 5124 0000 34369646 100000 1000 24084- 36126 30105

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 242 of 323

Data File vr479208d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 243 of 323

Data File vr479208d

Date 30-SEP-2012 1909

Client ID Instrument PESTGC9i

Sample Info ic SG1248L3_00013 Operator

10162012Page 244 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vf479209d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1254 Peak 1 50855015 - 51555085PCB-1254 Peak 2 62536183 - 63236253PCB-1254 Peak 3 65806510 - 66506580PCB-1254 Peak 4 71577087 - 72277157PCB-1254 Peak 5 73717301 - 74417371PCB-1254 Peak 6 85968526 - 86668596PCB-1254 Peak 7 90869016 - 91569086PCB-1254 Peak 8 98439773 - 99139843

FORM VI 8082 10162012Page 245 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992616 vf479209d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

97124PCB-1254 Peak 1 Ave 20097124230016374PCB-1254 Peak 2 Ave 20016373834017590PCB-1254 Peak 3 Ave 20017589776013684PCB-1254 Peak 4 Ave 20013683949027505PCB-1254 Peak 5 Ave 20027504947017262PCB-1254 Peak 6 Ave 20017261880028714PCB-1254 Peak 7 Ave 20028713900074774PCB-1254 Peak 8 Ave 200747739500

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 246 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vf479209d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1254 Peak 1 Ave 9712423 1000PCB-1254 Peak 2 Ave 16373834 1000PCB-1254 Peak 3 Ave 17589776 1000PCB-1254 Peak 4 Ave 13683949 1000PCB-1254 Peak 5 Ave 27504947 1000PCB-1254 Peak 6 Ave 17261880 1000PCB-1254 Peak 7 Ave 28713900 1000PCB-1254 Peak 8 Ave 7477395 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 247 of 323

Data File vf479209d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479209dLab Smp Id ic SG1254L3_00013 Inj Date 30-SEP-2012 1925 Operator Inst ID PESTGC9iSmp Info ic SG1254L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 16 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12540subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

26 Aroclor-1254 CAS 11097-69-1

5085 5085 0000 9712423 100000 1000 8000- 12000 10000

6253 6253 0000 16373834 100000 1000 13487- 20230 16859

6580 6580 0000 17589776 100000 1000 14488- 21733 18111

7157 7157 0000 13683949 100000 1000 11271- 16907 14089

7371 7371 0000 27504947 100000 1000 22655- 33983 28319

8596 8596 0000 17261880 100000 1000 14218- 21328 17773

9086 9086 0000 28713900 100000 1000 23651- 35477 29564

9843 9843 0000 7477395 100000 1000 6159- 9239 7699

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 248 of 323

Data File vf479209d

Date 30-SEP-2012 1925

Client ID Instrument PESTGC9i

Sample Info ic SG1254L3_00013 Operator

10162012Page 249 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vr479209d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1254 Peak 1 46874617 - 47574687PCB-1254 Peak 2 47624692 - 48324762PCB-1254 Peak 3 51285058 - 51985128PCB-1254 Peak 4 55695499 - 56395569PCB-1254 Peak 5 57705700 - 58405770PCB-1254 Peak 6 62216151 - 62916221PCB-1254 Peak 7 65216451 - 65916521PCB-1254 Peak 8 69656895 - 70356965

FORM VI 8082 10162012Page 250 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992616 vr479209d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

24886PCB-1254 Peak 1 Ave 20024885981024126PCB-1254 Peak 2 Ave 20024125717033197PCB-1254 Peak 3 Ave 20033196979024470PCB-1254 Peak 4 Ave 20024470162043009PCB-1254 Peak 5 Ave 20043008616038112PCB-1254 Peak 6 Ave 20038111884031186PCB-1254 Peak 7 Ave 20031186488041987PCB-1254 Peak 8 Ave 200419870070

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 251 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vr479209d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1254 Peak 1 Ave 24885981 1000PCB-1254 Peak 2 Ave 24125717 1000PCB-1254 Peak 3 Ave 33196979 1000PCB-1254 Peak 4 Ave 24470162 1000PCB-1254 Peak 5 Ave 43008616 1000PCB-1254 Peak 6 Ave 38111884 1000PCB-1254 Peak 7 Ave 31186488 1000PCB-1254 Peak 8 Ave 41987007 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 252 of 323

Data File vr479209d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479209dLab Smp Id ic SG1254L3_00013 Inj Date 30-SEP-2012 1925 Operator Inst ID PESTGC9iSmp Info ic SG1254L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 16 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12540subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

26 Aroclor-1254 CAS 11097-69-1

4687 4687 0000 24885981 100000 1000 8000- 12000 10000(M)

4762 4762 0000 24125717 100000 1000 7756- 11633 9695

5128 5128 0000 33196979 100000 1000 10672- 16008 13340

5569 5569 0000 24470162 100000 1000 7866- 11799 9833

5770 5770 0000 43008616 100000 1000 13826- 20739 17282

6221 6221 0000 38111884 100000 1000 12252- 18378 15315

6521 6521 0000 31186488 100000 1000 10025- 15038 12532

6965 6965 0000 41987007 100000 1000 13497- 20246 16872

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 253 of 323

Data File vr479209d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 254 of 323

Data File vr479209d

Date 30-SEP-2012 1925

Client ID Instrument PESTGC9i

Sample Info ic SG1254L3_00013 Operator

10162012Page 255 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-2

TestAmerica Edison

Lab File ID vf479493d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1005610273 979 1000 -21 150Ave

PCB-1016 Peak 2 2214321113 1050 1000 49 150Ave

PCB-1016 Peak 3 96058714 1100 1000 102 150Ave

PCB-1016 Peak 4 4004137710 1060 1000 62 150Ave

PCB-1016 Peak 5 1906116455 1160 1000 158 150Ave

PCB-1016 Peak 6 104069770 1070 1000 65 150Ave

PCB-1016 Peak 7 1271211990 1060 1000 60 150Ave

PCB-1016 Peak 8 1381712146 1140 1000 138 150Ave

PCB-1260 Peak 1 2403322106 1090 1000 87 150Ave

PCB-1260 Peak 2 2694125092 1070 1000 74 150Ave

PCB-1260 Peak 3 4112136867 1120 1000 115 150Ave

PCB-1260 Peak 4 1829116241 1130 1000 126 150Ave

PCB-1260 Peak 5 102408814 1160 1000 162 150Ave

PCB-1260 Peak 6 1863416926 1100 1000 101 150Ave

PCB-1260 Peak 7 2108721064 1000 1000 01 150Ave

PCB-1260 Peak 8 80147857 1020 1000 20 150Ave

DCB Decachlorobiphenyl 267686265963 101 100 06 150Ave

FORM VII 8082

10162012Page 256 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-2

TestAmerica Edison

Lab File ID vf479493d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 292 289 303

PCB-1016 Peak 2 359 357 371

PCB-1016 Peak 3 404 401 415

PCB-1016 Peak 4 443 441 455

PCB-1016 Peak 5 468 465 479

PCB-1016 Peak 6 511 509 523

PCB-1016 Peak 7 550 547 561

PCB-1016 Peak 8 571 568 582

PCB-1260 Peak 1 771 769 783

PCB-1260 Peak 2 816 814 828

PCB-1260 Peak 3 902 901 915

PCB-1260 Peak 4 928 926 940

PCB-1260 Peak 5 940 938 952

PCB-1260 Peak 6 986 983 997

PCB-1260 Peak 7 1059 1055 1069

PCB-1260 Peak 8 1106 1102 1116

DCB Decachlorobiphenyl 1149 1141 1161

Form VII 8082

10162012Page 257 of 323

Data File vf479493d Report Date 09-Oct-2012 0318

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479493dLab Smp Id ccvrtsg1660l3_00019 Inj Date 08-OCT-2012 1830 Operator Inst ID PESTGC9iSmp Info ccvrt-sg1660l3_00019Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 21 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2923 2961 -0038 10055641 978875 650 8000- 12000 10000(M)

3593 3641 -0048 22143043 104879 700 16892- 25338 22021

4036 4085 -0049 9604932 110224 730 6889- 10334 9552

4432 4479 -0047 40041013 106181 710 30481- 45721 39819

4678 4722 -0044 19061275 115840 770 13320- 19980 18956

5114 5158 -0044 10405886 106506 710 7564- 11346 10348

5500 5542 -0042 12711848 106020 710 9332- 13998 12642

5709 5752 -0043 13817418 113758 760 9784- 14675 13741

Average of Peak Concentrations = 720

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7706 7756 -0050 24033075 108715 720 8000- 12000 10000(M)

10162012Page 258 of 323

Data File vf479493d Report Date 09-Oct-2012 0318

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8161 8215 -0054 26941342 107369 720 9103- 13655 11210

9020 9084 -0064 41121424 111541 740 14090- 21136 17110

9276 9332 -0056 18291174 112626 750 6105- 9158 7611

9401 9454 -0053 10239798 116171 770 3460- 5190 4261

9861 9901 -0040 18634445 110097 730 6444- 9666 7754

10594 10616 -0022 21087197 100112 670 7926- 11889 12194

11063 11086 -0023 8014273 101999 680 2968- 4452 3335

Average of Peak Concentrations = 720

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11488 11515 -0027 26768608 100648 67 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 259 of 323

Data File vf479493d

Date 08-OCT-2012 1830

Client ID Instrument PESTGC9i

Sample Info ccvrt-sg1660l3_00019 Operator

10162012Page 260 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-1

TestAmerica Edison

Lab File ID vr479493d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1317915949 826 1000 -174 150Ave

PCB-1016 Peak 2 2492127231 915 1000 -85 150Ave

PCB-1016 Peak 3 1751817953 976 1000 -24 150Ave

PCB-1016 Peak 4 5583559495 938 1000 -62 150Ave

PCB-1016 Peak 5 2224122894 971 1000 -29 150Ave

PCB-1016 Peak 6 2383923697 1010 1000 06 150Ave

PCB-1016 Peak 7 2233922413 997 1000 -03 150Ave

PCB-1016 Peak 8 1103010158 1090 1000 86 150Ave

PCB-1260 Peak 1 3241432677 992 1000 -08 150Ave

PCB-1260 Peak 2 6068660467 1000 1000 04 150Ave

PCB-1260 Peak 3 5752255452 1040 1000 37 150Ave

PCB-1260 Peak 4 2973730164 986 1000 -14 150Ave

PCB-1260 Peak 5 2720927064 1010 1000 05 150Ave

PCB-1260 Peak 6 3391634367 987 1000 -13 150Ave

PCB-1260 Peak 7 2498721162 1180 1000 181 150Ave

PCB-1260 Peak 8 1900217245 1100 1000 102 150Ave

DCB Decachlorobiphenyl 482177470701 102 100 24 150Ave

FORM VII 8082

10162012Page 261 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-1

TestAmerica Edison

Lab File ID vr479493d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 206 201 215

PCB-1016 Peak 2 250 246 260

PCB-1016 Peak 3 275 271 285

PCB-1016 Peak 4 310 306 320

PCB-1016 Peak 5 330 326 340

PCB-1016 Peak 6 365 361 375

PCB-1016 Peak 7 401 397 411

PCB-1016 Peak 8 416 412 426

PCB-1260 Peak 1 604 600 614

PCB-1260 Peak 2 650 645 659

PCB-1260 Peak 3 694 689 703

PCB-1260 Peak 4 714 709 723

PCB-1260 Peak 5 757 753 767

PCB-1260 Peak 6 886 882 896

PCB-1260 Peak 7 908 904 918

PCB-1260 Peak 8 1013 1008 1022

DCB Decachlorobiphenyl 1061 1052 1072

Form VII 8082

10162012Page 262 of 323

Data File vr479493d Page 1 Report Date 09-Oct-2012 0318

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479493dLab Smp Id ccvrtsg1660l3_00019 Inj Date 08-OCT-2012 1830 Operator Inst ID PESTGC9iSmp Info ccvrt-sg1660l3_00019Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 21 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2056 2085 -0029 13178629 826281 550 8000- 12000 10000(M)

2498 2527 -0029 24921299 915181 610 13324- 19985 18910

2746 2777 -0031 17517717 975756 650 9975- 14963 13293

3100 3130 -0030 55834574 938480 620 29367- 44051 42368

3297 3330 -0033 22240639 971476 650 11758- 17638 16876

3648 3685 -0037 23838665 100597 670 11464- 17196 18089

4011 4043 -0032 22339236 996719 660 11819- 17728 16951

4157 4191 -0034 11029779 108584 720 5577- 8366 8369

Average of Peak Concentrations = 640

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6045 6072 -0027 32414247 991956 660 8000- 12000 10000(M)

10162012Page 263 of 323

Data File vr479493d Page 2 Report Date 09-Oct-2012 0318

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6496 6522 -0026 60686283 100362 670 14654- 21981 18722

6938 6964 -0026 57521890 103733 690 14108- 21162 17746

7137 7165 -0028 29736966 985849 660 7567- 11351 9174

7572 7602 -0030 27208663 100536 670 7053- 10579 8394

8857 8893 -0036 33916486 986885 660 9199- 13799 10463

9076 9115 -0039 24987061 118075 790 5953- 8930 7709

10135 10153 -0018 19001807 110187 730 4647- 6971 5862

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 48217685 102438 68 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 264 of 323

Data File vr479493d

Date 08-OCT-2012 1830

Client ID Instrument PESTGC9i

Sample Info ccvrt-sg1660l3_00019 Operator

10162012Page 265 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-2

TestAmerica Edison

Lab File ID vf479510d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 998310273 972 1000 -28 150Ave

PCB-1016 Peak 2 2182221113 1030 1000 34 150Ave

PCB-1016 Peak 3 93438714 1070 1000 72 150Ave

PCB-1016 Peak 4 3888937710 1030 1000 31 150Ave

PCB-1016 Peak 5 1831616455 1110 1000 113 150Ave

PCB-1016 Peak 6 100909770 1030 1000 33 150Ave

PCB-1016 Peak 7 1211711990 1010 1000 11 150Ave

PCB-1016 Peak 8 1287812146 1060 1000 60 150Ave

PCB-1260 Peak 1 2305022106 1040 1000 43 150Ave

PCB-1260 Peak 2 2601125092 1040 1000 37 150Ave

PCB-1260 Peak 3 4009636867 1090 1000 88 150Ave

PCB-1260 Peak 4 1793216241 1100 1000 104 150Ave

PCB-1260 Peak 5 100168814 1140 1000 136 150Ave

PCB-1260 Peak 6 1799416926 1060 1000 63 150Ave

PCB-1260 Peak 7 2148621064 1020 1000 20 150Ave

PCB-1260 Peak 8 78557857 1000 1000 -00 150Ave

DCB Decachlorobiphenyl 262499265963 987 100 -13 150Ave

FORM VII 8082

10162012Page 266 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-2

TestAmerica Edison

Lab File ID vf479510d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 292 289 303

PCB-1016 Peak 2 359 357 371

PCB-1016 Peak 3 403 401 415

PCB-1016 Peak 4 443 441 455

PCB-1016 Peak 5 468 465 479

PCB-1016 Peak 6 511 509 523

PCB-1016 Peak 7 550 547 561

PCB-1016 Peak 8 571 568 582

PCB-1260 Peak 1 770 769 783

PCB-1260 Peak 2 816 814 828

PCB-1260 Peak 3 902 901 915

PCB-1260 Peak 4 927 926 940

PCB-1260 Peak 5 940 938 952

PCB-1260 Peak 6 986 983 997

PCB-1260 Peak 7 1059 1055 1069

PCB-1260 Peak 8 1106 1102 1116

DCB Decachlorobiphenyl 1149 1141 1161

Form VII 8082

10162012Page 267 of 323

Data File vf479510d Report Date 09-Oct-2012 0335

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479510dLab Smp Id ccv-SG1660L3_00019 Inj Date 09-OCT-2012 0147 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 40 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2922 2961 -0039 9983429 971845 650 8000- 12000 10000(M)

3591 3641 -0050 21822420 103360 690 16892- 25338 21859

4034 4085 -0051 9342806 107216 710 6889- 10334 9358

4431 4479 -0048 38888611 103125 690 30481- 45721 38953

4677 4722 -0045 18315559 111308 740 13320- 19980 18346

5112 5158 -0046 10089629 103269 690 7564- 11346 10106

5497 5542 -0045 12117410 101063 670 9332- 13998 12138

5706 5752 -0046 12878214 106025 710 9784- 14675 12900

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7703 7756 -0053 23050032 104269 700 8000- 12000 10000(M)

10162012Page 268 of 323

Data File vf479510d Report Date 09-Oct-2012 0335

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8159 8215 -0056 26011086 103662 690 9103- 13655 11285

9017 9084 -0067 40095841 108759 720 14090- 21136 17395

9273 9332 -0059 17931794 110413 740 6105- 9158 7780

9399 9454 -0055 10016237 113634 760 3460- 5190 4345

9858 9901 -0043 17994170 106314 710 6444- 9666 7807

10594 10616 -0022 21485546 102003 680 7926- 11889 12478

11061 11086 -0025 7855172 999743 670 2968- 4452 3408

Average of Peak Concentrations = 710

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11485 11515 -0030 26249946 986977 66 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 269 of 323

Data File vf479510d

Date 09-OCT-2012 0147

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 270 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-1

TestAmerica Edison

Lab File ID vr479510d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1577315949 989 1000 -11 150Ave

PCB-1016 Peak 2 2637627231 969 1000 -31 150Ave

PCB-1016 Peak 3 1911517953 1060 1000 65 150Ave

PCB-1016 Peak 4 5729159495 963 1000 -37 150Ave

PCB-1016 Peak 5 2290722894 1000 1000 00 150Ave

PCB-1016 Peak 6 2510823697 1060 1000 60 150Ave

PCB-1016 Peak 7 2349222413 1050 1000 48 150Ave

PCB-1016 Peak 8 1095310158 1080 1000 78 150Ave

PCB-1260 Peak 1 3177332677 972 1000 -28 150Ave

PCB-1260 Peak 2 5864160467 970 1000 -30 150Ave

PCB-1260 Peak 3 5561155452 1000 1000 03 150Ave

PCB-1260 Peak 4 2920530164 968 1000 -32 150Ave

PCB-1260 Peak 5 2692527064 995 1000 -05 150Ave

PCB-1260 Peak 6 3316834367 965 1000 -35 150Ave

PCB-1260 Peak 7 2309521162 1090 1000 91 150Ave

PCB-1260 Peak 8 1649517245 957 1000 -43 150Ave

DCB Decachlorobiphenyl 444399470701 944 100 -56 150Ave

FORM VII 8082

10162012Page 271 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-1

TestAmerica Edison

Lab File ID vr479510d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 206 201 215

PCB-1016 Peak 2 250 246 260

PCB-1016 Peak 3 275 271 285

PCB-1016 Peak 4 310 306 320

PCB-1016 Peak 5 330 326 340

PCB-1016 Peak 6 365 361 375

PCB-1016 Peak 7 401 397 411

PCB-1016 Peak 8 416 412 426

PCB-1260 Peak 1 604 600 614

PCB-1260 Peak 2 649 645 659

PCB-1260 Peak 3 694 689 703

PCB-1260 Peak 4 714 709 723

PCB-1260 Peak 5 757 753 767

PCB-1260 Peak 6 885 882 896

PCB-1260 Peak 7 907 904 918

PCB-1260 Peak 8 1013 1008 1022

DCB Decachlorobiphenyl 1061 1052 1072

Form VII 8082

10162012Page 272 of 323

Data File vr479510d Page 1 Report Date 09-Oct-2012 0335

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479510dLab Smp Id ccv-SG1660L3_00019 Inj Date 09-OCT-2012 0147 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 40 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2056 2085 -0029 15772630 988922 660 8000- 12000 10000(M)

2498 2527 -0029 26375750 968593 640 13324- 19985 16722

2747 2777 -0030 19114706 106471 710 9975- 14963 12119

3099 3130 -0031 57290957 962959 640 29367- 44051 36323

3296 3330 -0034 22907341 100060 670 11758- 17638 14523

3645 3685 -0040 25108132 105954 710 11464- 17196 15919

4009 4043 -0034 23491941 104815 700 11819- 17728 14894

4155 4191 -0036 10952986 107828 720 5577- 8366 6944

Average of Peak Concentrations = 680

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6043 6072 -0029 31772880 972329 650 8000- 12000 10000(M)

10162012Page 273 of 323

Data File vr479510d Page 2 Report Date 09-Oct-2012 0335

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6494 6522 -0028 58641225 969803 650 14654- 21981 18456

6936 6964 -0028 55611337 100287 670 14108- 21162 17503

7135 7165 -0030 29205460 968228 640 7567- 11351 9192

7570 7602 -0032 26925453 994891 660 7053- 10579 8474

8854 8893 -0039 33168029 965107 640 9199- 13799 10439

9072 9115 -0043 23094940 109134 730 5953- 8930 7269

10132 10153 -0021 16495029 956510 640 4647- 6971 5192

Average of Peak Concentrations = 660

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 44439946 944122 63 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 274 of 323

Data File vr479510d

Date 09-OCT-2012 0147

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 275 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1309971-A

Matrix vf479496dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2208

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

88 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 276 of 323

Data File vf479496d Report Date 09-Oct-2012 0319

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479496dLab Smp Id MB 460-1309971-a Inj Date 08-OCT-2012 2208 Operator Inst ID PESTGC9iSmp Info MB 460-1309971-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 24 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11484 11515 -0031 23517325 884233 59 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 277 of 323

Data File vf479496d

Date 08-OCT-2012 2208

Client ID Instrument PESTGC9i

Sample Info MB 460-1309971-a Operator

10162012Page 278 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1309971-A

Matrix vr479496dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2208

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

97 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 279 of 323

Data File vr479496d Page 1 Report Date 09-Oct-2012 0319

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479496dLab Smp Id MB 460-1309971-a Inj Date 08-OCT-2012 2208 Operator Inst ID PESTGC9iSmp Info MB 460-1309971-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 24 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 45589434 968543 64 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 280 of 323

Data File vr479496d

Date 08-OCT-2012 2208

Client ID Instrument PESTGC9i

Sample Info MB 460-1309971-a Operator

10162012Page 281 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-1311371

Matrix vf479492dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10082012 1814Sample wtvol

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

114 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 282 of 323

Data File vf479492d Page 1 Report Date 09-Oct-2012 0317

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479492dLab Smp Id piblk-sgpiblk_00013 Inj Date 08-OCT-2012 1814 Operator Inst ID PESTGC9iSmp Info sgpiblk_00013Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 20 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11496 11515 -0019 6086041 228830 15 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 283 of 323

Data File vf479492d

Date 08-OCT-2012 1814

Client ID Instrument PESTGC9i

Sample Info sgpiblk_00013 Operator

10162012Page 284 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-1311371

Matrix vr479492dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10082012 1814Sample wtvol

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

114 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 285 of 323

Data File vr479492d Report Date 09-Oct-2012 0317

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479492dLab Smp Id piblk-sgpiblk_00013 Inj Date 08-OCT-2012 1814 Operator Inst ID PESTGC9iSmp Info sgpiblk_00013Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 20 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 10738471 228138 15 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 286 of 323

Data File vr479492d

Date 08-OCT-2012 1814

Client ID Instrument PESTGC9i

Sample Info sgpiblk_00013 Operator

10162012Page 287 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-13113718

Matrix vf479509dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10092012 0131Sample wtvol

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

122 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 288 of 323

Data File vf479509d Report Date 09-Oct-2012 0313

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479509dLab Smp Id SGPIBLK_00013 Inj Date 09-OCT-2012 0131 Operator Inst ID PESTGC9iSmp Info SGPIBLK_00013Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 39 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11487 11515 -0028 6469383 243244 16 8000- 12000 10000(a)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 289 of 323

Data File vf479509d

Date 09-OCT-2012 0131

Client ID Instrument PESTGC9i

Sample Info SGPIBLK_00013 Operator

10162012Page 290 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-13113718

Matrix vr479509dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10092012 0131Sample wtvol

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

102 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 291 of 323

Data File vr479509d Report Date 09-Oct-2012 0306

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479509dLab Smp Id SGPIBLK_00013 Inj Date 09-OCT-2012 0131 Operator Inst ID PESTGC9iSmp Info SGPIBLK_00013Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 39 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 9634357 204681 14 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 292 of 323

Data File vr479509d

Date 09-OCT-2012 0131

Client ID Instrument PESTGC9i

Sample Info SGPIBLK_00013 Operator

10162012Page 293 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1309972-A

Matrix vf479497dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2224

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 507

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 557

RECCAS NO LIMITSQSURROGATE

84 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 294 of 323

Data File vf479497d Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479497dLab Smp Id LCS 460-1309972-a Inj Date 08-OCT-2012 2224 Operator Inst ID PESTGC9iSmp Info LCS 460-1309972-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 25 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2926 2961 -0035 10792080 105056 700 8000- 12000 10000

3596 3641 -0045 23726579 112379 750 16892- 25338 21985

4040 4085 -0045 9881475 113398 760 6889- 10334 9156

4437 4479 -0042 42082916 111596 740 30481- 45721 38994

4683 4722 -0039 19556228 118847 790 13320- 19980 18121

5181 5158 0023 7863050 804795 540 7564- 11346 7286

5572 5542 0030 6208245 517785 340 9332- 13998 5753

5713 5752 -0039 14198514 116895 780 9784- 14675 13156

Average of Peak Concentrations = 680

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7711 7756 -0045 26515963 119947 800 8000- 12000 10000(M)

10162012Page 295 of 323

Data File vf479497d Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8168 8215 -0047 29809525 118800 790 9103- 13655 11242

9026 9084 -0058 46049501 124909 830 14090- 21136 17367

9283 9332 -0049 20194161 124344 830 6105- 9158 7616

9408 9454 -0046 11340121 128654 860 3460- 5190 4277

9864 9901 -0037 20709127 122354 820 6444- 9666 7810

10623 10616 0007 8913638 423178 280 7926- 11889 3362

11063 11086 -0023 8650385 110095 730 2968- 4452 3262

Average of Peak Concentrations = 740

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11484 11515 -0031 22216113 835308 56 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 296 of 323

Data File vf479497d

Date 08-OCT-2012 2224

Client ID Instrument PESTGC9i

Sample Info LCS 460-1309972-a Operator

10162012Page 297 of 323

Manual Integration Report

Data File vf479497dInj Date and Time 08-OCT-2012 2224Instrument ID PESTGC9iClient ID Compound 27 Aroclor-1260CAS 11096-82-5Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 776

Manual Integration Results

RT 771

Response 26515963

Amount 111428

Conc 74000

Manually Integrated By diazcManual Integration Reason

10162012Page 298 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1309972-A

Matrix vr479497dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2224

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 483

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 573

RECCAS NO LIMITSQSURROGATE

91 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 299 of 323

Data File vr479497d Page 1 Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479497dLab Smp Id LCS 460-1309972-a Inj Date 08-OCT-2012 2224 Operator Inst ID PESTGC9iSmp Info LCS 460-1309972-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 25 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2058 2085 -0027 15080112 945502 630 8000- 12000 10000(M)

2502 2527 -0025 26928755 988901 660 13324- 19985 17857

2750 2777 -0027 19042665 106070 710 9975- 14963 12628

3103 3130 -0027 59594211 100167 670 29367- 44051 39518

3301 3330 -0029 23808984 103998 690 11758- 17638 15788

3694 3685 0009 14297782 603352 400 11464- 17196 9481

4013 4043 -0030 24245185 108176 720 11819- 17728 16078

4188 4191 -0003 10255607 100963 670 5577- 8366 6801

Average of Peak Concentrations = 640

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6048 6072 -0024 36196886 110771 740 8000- 12000 10000

10162012Page 300 of 323

Data File vr479497d Page 2 Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6500 6522 -0022 67525585 111673 740 14654- 21981 18655

6943 6964 -0021 64479188 116279 780 14108- 21162 17813

7142 7165 -0023 33072749 109644 730 7567- 11351 9137

7578 7602 -0024 30577540 112984 750 7053- 10579 8448

8864 8893 -0029 38421619 111797 740 9199- 13799 10615

9083 9115 -0032 26202367 123818 820 5953- 8930 7239

10138 10153 -0015 20706585 120073 800 4647- 6971 5721

Average of Peak Concentrations = 760

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 42991277 913346 61 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 301 of 323

Data File vr479497d

Date 08-OCT-2012 2224

Client ID Instrument PESTGC9i

Sample Info LCS 460-1309972-a Operator

10162012Page 302 of 323

Manual Integration Report

Data File vr479497dInj Date and Time 08-OCT-2012 2224Instrument ID PESTGC9iClient ID Compound 21 Aroclor-1016CAS 12674-11-2Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 208

Manual Integration Results

RT 206

Response 15080112

Amount 96644

Conc 64000

Manually Integrated By diazcManual Integration Reason

10162012Page 303 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCSD 460-1309973-A

Matrix vf479498dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2239

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 516

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 583

RECCAS NO LIMITSQSURROGATE

99 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 304 of 323

Data File vf479498d Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479498dLab Smp Id LCSd 460-1309973-a Inj Date 08-OCT-2012 2239 Operator Inst ID PESTGC9iSmp Info LCSd 460-1309973-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 26 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2925 2961 -0036 10994509 107027 710 8000- 12000 10000

3594 3641 -0047 24222192 114726 760 16892- 25338 22031

4039 4085 -0046 9969671 114410 760 6889- 10334 9068

4435 4479 -0044 43128755 114369 760 30481- 45721 39228

4680 4722 -0042 19946065 121217 810 13320- 19980 18142

5177 5158 0019 7960960 814816 540 7564- 11346 7241

5569 5542 0027 6392667 533166 360 9332- 13998 5814

5711 5752 -0041 14546887 119763 800 9784- 14675 13231

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7708 7756 -0048 27193660 123013 820 8000- 12000 10000(M)

10162012Page 305 of 323

Data File vf479498d Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8164 8215 -0051 30632211 122078 810 9103- 13655 11264

9022 9084 -0062 47541251 128955 860 14090- 21136 17482

9278 9332 -0054 21062846 129693 860 6105- 9158 7745

9404 9454 -0050 11787377 133728 890 3460- 5190 4335

9862 9901 -0039 21547760 127309 850 6444- 9666 7924

10618 10616 0002 10677528 506919 340 7926- 11889 3926

11062 11086 -0024 9277293 118074 790 2968- 4452 3412

Average of Peak Concentrations = 780

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11482 11515 -0033 26307958 989158 66 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 306 of 323

Data File vf479498d

Date 08-OCT-2012 2239

Client ID Instrument PESTGC9i

Sample Info LCSd 460-1309973-a Operator

10162012Page 307 of 323

Manual Integration Report

Data File vf479498dInj Date and Time 08-OCT-2012 2239Instrument ID PESTGC9iClient ID Compound 27 Aroclor-1260CAS 11096-82-5Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 776

Manual Integration Results

RT 771

Response 27193660

Amount 116693

Conc 78000

Manually Integrated By diazcManual Integration Reason

10162012Page 308 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCSD 460-1309973-A

Matrix vr479498dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2239

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 497

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 595

RECCAS NO LIMITSQSURROGATE

108 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 309 of 323

Data File vr479498d Page 1 Report Date 09-Oct-2012 0321

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479498dLab Smp Id LCSd 460-1309973-a Inj Date 08-OCT-2012 2239 Operator Inst ID PESTGC9iSmp Info LCSd 460-1309973-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 26 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2058 2085 -0027 15401465 965650 640 8000- 12000 10000(M)

2501 2527 -0026 27477458 100905 670 13324- 19985 17841

2750 2777 -0027 19458638 108387 720 9975- 14963 12634

3102 3130 -0028 60672366 101979 680 29367- 44051 39394

3299 3330 -0031 24206974 105737 700 11758- 17638 15717

3679 3685 -0006 17478185 737562 490 11464- 17196 11348

4012 4043 -0031 24592091 109724 730 11819- 17728 15967

4189 4191 -0002 9970290 981538 650 5577- 8366 6474

Average of Peak Concentrations = 660

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6047 6072 -0025 36957605 113099 750 8000- 12000 10000

10162012Page 310 of 323

Data File vr479498d Page 2 Report Date 09-Oct-2012 0321

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6498 6522 -0024 69036402 114172 760 14654- 21981 18680

6940 6964 -0024 66037968 119090 790 14108- 21162 17869

7140 7165 -0025 33956993 112575 750 7567- 11351 9188

7575 7602 -0027 31643763 116923 780 7053- 10579 8562

8861 8893 -0032 40016219 116437 780 9199- 13799 10828

9080 9115 -0035 27744305 131104 870 5953- 8930 7507

10136 10153 -0017 22040150 127806 850 4647- 6971 5964

Average of Peak Concentrations = 790

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10612 10624 -0012 50942327 108226 72 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 311 of 323

Data File vr479498d

Date 08-OCT-2012 2239

Client ID Instrument PESTGC9i

Sample Info LCSd 460-1309973-a Operator

10162012Page 312 of 323

Manual Integration Report

Data File vr479498dInj Date and Time 08-OCT-2012 2239Instrument ID PESTGC9iClient ID Compound 21 Aroclor-1016CAS 12674-11-2Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 208

Manual Integration Results

RT 206

Response 15401465

Amount 99401

Conc 66000

Manually Integrated By diazcManual Integration Reason

10162012Page 313 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GC SEMI VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

PESTGC9

129926

Start Date

End Date 09302012 2043

09302012 1530

RINSE 460-1299261 CLP-2 053(mm)109302012 1530

RINSE 460-1299261 CLP-1 053(mm)109302012 1530

RINSE 460-1299262 CLP-2 053(mm)109302012 1546

RINSE 460-1299262 CLP-1 053(mm)109302012 1546

ZZZZZ CLP-2 053(mm)109302012 1602

ZZZZZ CLP-1 053(mm)109302012 1602

ZZZZZ CLP-2 053(mm)109302012 1617

ZZZZZ CLP-1 053(mm)109302012 1617

ZZZZZ CLP-2 053(mm)109302012 1633

ZZZZZ CLP-1 053(mm)109302012 1633

ZZZZZ CLP-2 053(mm)109302012 1649

ZZZZZ CLP-1 053(mm)109302012 1649

IC 460-1299267 CLP-2 053(mm)109302012 1704 vf479200d

IC 460-1299267 CLP-1 053(mm)109302012 1704 vr479200d

IC 460-1299268 CLP-2 053(mm)109302012 1720 vf479201d

IC 460-1299268 CLP-1 053(mm)109302012 1720 vr479201d

IC 460-1299269 CLP-2 053(mm)109302012 1735 vf479202d

IC 460-1299269 CLP-1 053(mm)109302012 1735 vr479202d

IC 460-12992610 CLP-2 053(mm)109302012 1751 vf479203d

IC 460-12992610 CLP-1 053(mm)109302012 1751 vr479203d

IC 460-12992611 CLP-2 053(mm)109302012 1807 vf479204d

IC 460-12992611 CLP-1 053(mm)109302012 1807 vr479204d

IC 460-12992612 CLP-2 053(mm)109302012 1822 vf479205d

IC 460-12992612 CLP-1 053(mm)109302012 1822 vr479205d

IC 460-12992613 CLP-2 053(mm)109302012 1838 vf479206d

IC 460-12992613 CLP-1 053(mm)109302012 1838 vr479206d

IC 460-12992614 CLP-2 053(mm)109302012 1854 vf479207d

IC 460-12992614 CLP-1 053(mm)109302012 1854 vr479207d

IC 460-12992615 CLP-2 053(mm)109302012 1909 vf479208d

IC 460-12992615 CLP-1 053(mm)109302012 1909 vr479208d

IC 460-12992616 CLP-2 053(mm)109302012 1925 vf479209d

IC 460-12992616 CLP-1 053(mm)109302012 1925 vr479209d

IC 460-12992617 CLP-2 053(mm)109302012 1940

IC 460-12992617 CLP-1 053(mm)109302012 1940

IC 460-12992618 CLP-2 053(mm)109302012 1956

IC 460-12992618 CLP-1 053(mm)109302012 1956

ZZZZZ CLP-2 053(mm)109302012 2011

ZZZZZ CLP-1 053(mm)109302012 2011

ZZZZZ CLP-2 053(mm)109302012 2027

ZZZZZ CLP-1 053(mm)109302012 2027

ZZZZZ CLP-2 053(mm)109302012 2043

ZZZZZ CLP-1 053(mm)109302012 2043

8082

10162012Page 314 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GC SEMI VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

PESTGC9

131137

Start Date

End Date 10092012 0147

10082012 1814

PIBLK 460-1311371 CLP-2 053(mm)110082012 1814 vf479492d

PIBLK 460-1311371 CLP-1 053(mm)110082012 1814 vr479492d

CCVRT 460-1311372 CLP-2 053(mm)110082012 1830 vf479493d

CCVRT 460-1311372 CLP-1 053(mm)110082012 1830 vr479493d

ZZZZZ CLP-2 053(mm)110082012 2137

ZZZZZ CLP-1 053(mm)110082012 2137

ZZZZZ CLP-2 053(mm)110082012 2152

ZZZZZ CLP-1 053(mm)110082012 2152

MB 460-1309971-A CLP-2 053(mm)110082012 2208 vf479496d

MB 460-1309971-A CLP-1 053(mm)110082012 2208 vr479496d

LCS 460-1309972-A CLP-2 053(mm)110082012 2224 vf479497d

LCS 460-1309972-A CLP-1 053(mm)110082012 2224 vr479497d

LCSD 460-1309973-A CLP-2 053(mm)110082012 2239 vf479498d

LCSD 460-1309973-A CLP-1 053(mm)110082012 2239 vr479498d

ZZZZZ CLP-2 053(mm)110082012 2255

ZZZZZ CLP-1 053(mm)110082012 2255

ZZZZZ CLP-2 053(mm)110082012 2311

ZZZZZ CLP-1 053(mm)110082012 2311

ZZZZZ CLP-2 053(mm)110082012 2326

ZZZZZ CLP-1 053(mm)110082012 2326

ZZZZZ CLP-2 053(mm)110082012 2342

ZZZZZ CLP-1 053(mm)110082012 2342

ZZZZZ CLP-2 053(mm)110082012 2358

ZZZZZ CLP-1 053(mm)110082012 2358

ZZZZZ CLP-2 053(mm)110092012 0013

ZZZZZ CLP-1 053(mm)110092012 0013

460-45537-1 WC-17338-100512-MW14-MM-251

CLP-2 053(mm)110092012 0029 vf479505d

460-45537-1 WC-17338-100512-MW14-MM-251

CLP-1 053(mm)110092012 0029 vr479505d

460-45537-2 WC-17338-100512-MW101-MM-252

CLP-2 053(mm)110092012 0045 vf479506d

460-45537-2 WC-17338-100512-MW101-MM-252

CLP-1 053(mm)110092012 0045 vr479506d

ZZZZZ CLP-2 053(mm)110092012 0100

ZZZZZ CLP-1 053(mm)110092012 0100

ZZZZZ CLP-2 053(mm)110092012 0116

ZZZZZ CLP-1 053(mm)110092012 0116

PIBLK 460-13113718 CLP-2 053(mm)110092012 0131 vf479509d

PIBLK 460-13113718 CLP-1 053(mm)110092012 0131 vr479509d

CCV 460-13113719 CLP-2 053(mm)110092012 0147 vf479510d

CCV 460-13113719 CLP-1 053(mm)110092012 0147 vr479510d

8082

10162012Page 315 of 323

10162012Page 316 of 323

10162012Page 317 of 323

10162012Page 318 of 323

10162012Page 319 of 323

Lab Name Job No

SDG No

GC SEMI VOA BATCH WORKSHEET

460-45537-1

Batch Number Batch AnalystBatch Start Date

Batch End Date

Wu Huachi

100812 1800

100812 0754130997

Batch Method

TestAmerica Edison

3510C

Lab Sample ID Client Sample ID Method Chain Basis ReceivedpH InitialAmount FinalAmount OP_PCBSP 00024 OPPSTPCBSU 00021

AnalysisComment

7 1000 mL 5 mL 50 uL Acid Cleaning_UP

MB 460-1309971 3510C 8082

7 1000 mL 5 mL 50 uL 50 uL Acid Cleaning_UP

LCS 460-1309972

3510C 8082

7 1000 mL 5 mL 50 uL 50 uL Acid Cleaning_UP

LCSD 460-1309973

3510C 8082

WC-17338-100512-MW14-MM-251

7 980 mL 5 mL 50 uL Acid Cleaning_UP

460-45537-E-1 3510C 8082 T

WC-17338-100512-MW101-MM-252

7 990 mL 5 mL 50 uL Acid Cleaning_UP

460-45537-E-2 3510C 8082 T

Batch Notes

Batch Comment 8082Acid Cleaning_up Lot 20042

Persons name who did the concentration Wuh

Exchange Solvent Lot 6383

Exchange Solvent Name Hexane

Final Concentrator Volume 5 mL

N-evap temperature 35 Degrees C

Na2SO4 Lot Number 213204

Prep Solvent Lot 14764

Prep Solvent Name Mecl2

Prep Solvent Volume Used 180 ml mL

Persons name who did the prep Wuh

Persons name who witnessed reagent drop HCP

Basis Basis Description

T TotalNA

Page 1 of 18082

10162012Page 320 of 323

Shipping and

Receiving

Documents

10162012Page 321 of 323

10162012Page 322 of 323

Login Sample Receipt Checklist

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Login Number 45537

Question Answer Comment

Creator Hall Alonzo

List Source TestAmerica Edison

List Number 1

NARadioactivity wasnt checked or is lt= background as measured by a survey

meter

NAThe coolers custody seal if present is intact Not present

TrueSample custody seals if present are intact

TrueThe cooler or samples do not appear to have been compromised or

tampered with

TrueSamples were received on ice

TrueCooler Temperature is acceptable

TrueCooler Temperature is recorded 32deg C IR 2

TrueCOC is present

TrueCOC is filled out in ink and legible

TrueCOC is filled out with all pertinent information

TrueIs the Field Samplers name present on COC

TrueThere are no discrepancies between the containers received and the COC

TrueSamples are received within Holding Time

TrueSample containers have legible labels

TrueContainers are not broken or leaking

TrueSample collection datetimes are provided

TrueAppropriate sample containers are used

TrueSample bottles are completely filled

TrueSample Preservation Verified

TrueThere is sufficient vol for all requested analyses incl any requested

MSMSDs

TrueContainers requiring zero headspace have no headspace or bubble is

lt6mm (14)

NAMultiphasic samples are not present

NASamples do not require splitting or compositing

NAResidual Chlorine Checked No analysis requiring residual chlorine check

assigned

TestAmerica Edison 10162012Page 323 of 323

  • Cover Title Page
  • Table of Contents
  • Data Summaries
    • Report Narrative
    • Sample Summary
    • Executive Summary
    • Method Summary
    • Method Analyst Summary
    • Sample Datasheets
    • Surrogate Summary
    • QC Data Summary
    • Data Qualifiers
    • QC Association Summary
    • Lab Chronicle
      • Organic Sample Data
        • GCMS VOA
          • Method 8260 DEL
            • Method 8260 DEL QC Summary
            • Method 8260 DEL Sample Data
            • Standards Data
              • Method 8260 DEL ICAL Data
              • Method 8260 DEL CCAL Data
                • Raw QC Data
                  • Method 8260 DEL Tune Data
                  • Method 8260 DEL Blank Data
                  • Method 8260 DEL LCSLCSD Data
                  • Method 8260 DEL MSMSD Data
                    • Method 8260 DEL Run Logs
                    • Method 8260 DEL Prep Data
                        • GC Semi VOA
                          • Method 8082 - Delaware
                            • Method 8082 - Delaware QC Summary
                            • Method 8082 - Delaware Sample Data
                            • Standards Data
                              • Method 8082 - Delaware ICAL Data
                              • Method 8082 - Delaware CCAL Data
                                • Raw QC Data
                                  • Method 8082 - Delaware Blank Data
                                  • Method 8082 - Delaware LCSLCSD Data
                                    • Method 8082 - Delaware Run Logs
                                    • Method 8082 - Delaware Prep Data
                                      • Shipping and Receiving Documents
                                        • Client Chain of Custody
                                        • Sample Receipt Checklist
Page 3: J45537-1 Nj Full Package Final Report

Table of ContentsMethod 8260 DEL Run Logs 134Method 8260 DEL Prep Data 136

GC Semi VOA 140

Method 8082 - Delaware 140Method 8082 - Delaware QC Summary 141Method 8082 - Delaware Sample Data 151Standards Data 163

Method 8082 - Delaware ICAL Data 163Method 8082 - Delaware CCAL Data 256

Raw QC Data 276Method 8082 - Delaware Blank Data 276Method 8082 - Delaware LCSLCSD Data 294

Method 8082 - Delaware Run Logs 314Method 8082 - Delaware Prep Data 316

Shipping and Receiving Documents 321

Client Chain of Custody 322

Sample Receipt Checklist 323

10162012Page 3 of 323

CASE NARRATIVE

Client Conestoga-Rovers amp Associates Inc

Project 17338-TO4-2012 RACER GM Wilmington

Report Number 460-45537-1

This case narrative is in the form of an exception report where only the anomalies related to this report method specific performance

andor QAQC issues are discussed If there are no issues to report this narrative will include a statement that documents that there are

no relevant data issues

It should be noted that samples with elevated Reporting Limits (RLs) as a result of a dilution may not be able to satisfy customer reporting

limits in some cases Such increases in the RLs are unavoidable but acceptable consequence of sample dilution that enables

quantification of target analytes or interferences which exceed the calibration range of the instrument

Calculations are performed before rounding to avoid round-off errors in calculated results

All holding times were met and proper preservation noted for the methods performed on these samples unless otherwise detailed in the

individual sections below

RECEIPT

The samples were received on 10052012 710 PM the samples arrived in good condition properly preserved and on ice The

temperature of the coolers at receipt was 32 C

Note All samples which require thermal preservation are considered acceptable if the arrival temperature is within 2C of the required

temperature or method specified range For samples with a specified temperature of 4C samples with a temperature ranging from just

above freezing temperature of water to 6C shall be acceptable Samples that are hand delivered immediately following collection may not

meet these criteria however they will be deemed acceptable according to NELAC standards if there is evidence that the chilling process

has begun such as arrival on ice etc

POLYCHLORINATED BIPHENYLS (PCBS)

Samples 460-45537-1 and 460-45537-2 were analyzed for polychlorinated biphenyls (PCBs) in accordance with EPA SW-846 Method

8082DEL The samples were prepared on 10082012 and analyzed on 10092012

No difficulties were encountered during the PCBs analyses

All quality control parameters were within the acceptance limits

VOLATILE ORGANIC COMPOUNDS (GC-MS)

Samples 460-45537-1 through 460-45537-3 were analyzed for volatile organic compounds (GC-MS) in accordance with EPA SW-846

Method 8260B The samples were analyzed on 10112012 and 10122012

The matrix spike matrix spike duplicate (MSMSD) recoveries for batch 131656 were outside control limits 12-Dibromo-3-chloropropane

The MSD recoveries were also outside control limits for trans-13-Dichloropropene and Methyl tert-butyl ether The associated laboratory

control sample (LCS) recoveries met acceptance criteria

12-Dibromo-3-Chloropropane failed the recovery criteria high for the MS of sample 460-45537-2 in batch 460-131656

12-Dibromo-3-Chloropropane Methyl tert-butyl ether and trans-13-Dichloropropene failed the recovery criteria high for the MSD of

sample 460-45537-2 in batch 460-131656

Refer to the QC report for details

No other difficulties were encountered during the volatiles analyses

All other quality control parameters were within the acceptance limits

10162012Page 4 of 323

SAMPLE SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample IDLab Sample ID Client Matrix Sampled Received

DateTime DateTime

460-45537-1 WC-17338-100512-MW14-MM-2

51

Water 10052012 1000 10052012 1910

460-45537-2 WC-17338-100512-MW101-MM-

252

Water 10052012 1230 10052012 1910

460-45537-3TB TB-17338-100512-253 Water 10052012 0000 10052012 1910

TestAmerica Edison 10162012Page 5 of 323

EXECUTIVE SUMMARY - Detections

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Analyte Result

Reporting

Limit Units Method

Lab Sample ID Client Sample ID

Qualifier

460-45537-1 WC-17338-100512-MW14-MM-251

10 ugL 8260B017 JMethyl tert-butyl ether

10 ugL 8260B017 JToluene

10 ugL 8260B028 JTetrachloroethene

460-45537-2 WC-17338-100512-MW101-MM-252

10 ugL 8260B020 JMethyl tert-butyl ether

460-45537-3TB TB-17338-100512-253

10 ugL 8260B074 JMethylene Chloride

10 ugL 8260B0096 JChloroform

TestAmerica Edison 10162012Page 6 of 323

METHOD SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Preparation MethodMethodLab LocationDescription

Matrix Water

Volatile Organics (GCMS) TAL EDI SW846 8260B

Purge and Trap TAL EDI SW846 5030B

Polychlorinated Biphenyls (PCBs) (GC) TAL EDI SW846 8082

Liquid-Liquid Extraction (Separatory Funnel) TAL EDI SW846 3510C

Lab References

TAL EDI = TestAmerica Edison

Method References

SW846 = Test Methods For Evaluating Solid Waste PhysicalChemical Methods Third Edition November 1986 And Its Updates

TestAmerica Edison 10162012Page 7 of 323

METHOD ANALYST SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Method Analyst Analyst ID

Boykin Kenneth KBSW846 8260B

Boykin Carol B CBBSW846 8082

TestAmerica Edison

10162012Page 8 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

017 J 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

017 J 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

028 J 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 9 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

99 70 - 1304-Bromofluorobenzene

96 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 10 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 11 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

020 J 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 12 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

98 70 - 1304-Bromofluorobenzene

97 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 13 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 14 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

074 J 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

014 U 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0096 J 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 15 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

99 70 - 1304-Bromofluorobenzene

97 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 16 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 17 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0029

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type PRIMARY

980 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

013 U 051013PCB-1016

029 U 051029PCB-1221

012 U 051012PCB-1232

012 U 051012PCB-1242

024 U 051024PCB-1248

017 U 051017PCB-1254

015 U 051015PCB-1260

Surrogate Rec Acceptance LimitsQualifier

83 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 18 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0029

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type SECONDARY

980 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Surrogate Rec Acceptance LimitsQualifier

82 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 19 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0045

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type PRIMARY

990 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

013 U 051013PCB-1016

028 U 051028PCB-1221

012 U 051012PCB-1232

012 U 051012PCB-1242

024 U 051024PCB-1248

017 U 051017PCB-1254

015 U 051015PCB-1260

Surrogate Rec Acceptance LimitsQualifier

52 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 20 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0045

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type SECONDARY

990 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Surrogate Rec Acceptance LimitsQualifier

50 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 21 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Surrogate Recovery Report

8260B Volatile Organics (GCMS)

Client Matrix Water

Lab Sample ID Client Sample ID

DCA TOL BFB

Rec Rec Rec

460-45537-1 WC-17338-100512-M

W14-MM-251

97 96 99

460-45537-2 WC-17338-100512-M

W101-MM-252

97 97 98

460-45537-3 TB-17338-100512-25

3

97 97 99

MB 460-1316564 99 96 95

LCS 460-1316563 96 99 97

460-45537-2 MS WC-17338-100512-M

W101-MM-252 MS

96 99 99

460-45537-2 MSD WC-17338-100512-M

W101-MM-252 MSD

96 99 97

Surrogate Acceptance Limits

DCA = 12-Dichloroethane-d4 (Surr) 70-130

TOL = Toluene-d8 (Surr) 70-130

BFB = 4-Bromofluorobenzene 70-130

TestAmerica Edison

10162012Page 22 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Surrogate Recovery Report

8082 Polychlorinated Biphenyls (PCBs) (GC)

Client Matrix Water

Lab Sample ID Client Sample ID

DCB1 DCB2

Rec Rec

460-45537-1 WC-17338-100512-M

W14-MM-251

82 83

460-45537-2 WC-17338-100512-M

W101-MM-252

52 50

MB 460-1309971-A 97 88

LCS 460-1309972-A 91 84

LCSD

460-1309973-A

108 99

Surrogate Acceptance Limits

DCB = DCB Decachlorobiphenyl 37-150

TestAmerica Edison

10162012Page 23 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-131656

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08981d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5MB 460-1316564

Analysis Date 10112012 2247

Analysis Batch

Prep Batch

Leach Batch

NA

NA

460-131656

Prep Date

Leach Date

10112012 2247

NA

Analyte RLMDLQualResult

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

014 U 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

TestAmerica Edison 10162012Page 24 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-131656

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08981d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5MB 460-1316564

Analysis Date 10112012 2247

Analysis Batch

Prep Batch

Leach Batch

NA

NA

460-131656

Prep Date

Leach Date

10112012 2247

NA

Analyte RLMDLQualResult

014 U 1001413-Dichlorobenzene

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance Limits

12-Dichloroethane-d4 (Surr) 99 70 - 130

4-Bromofluorobenzene 95 70 - 130

Toluene-d8 (Surr) 96 70 - 130

Method Blank TICs- Batch 460-131656

Cas Number Analyte RT Est Result Qual

Tentatively Identified Compound None

TestAmerica Edison 10162012Page 25 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10

Lab Control Sample - Batch 460-131656

Client Matrix

Lab Sample ID

Dilution

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08977d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5LCS 460-1316563

Analysis Date 10112012 2113

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Prep Date

Leach Date

10112012 2113

NA

Analyte QualLimit RecResultSpike Amount

200 210 105 74 - 128111-Trichloroethane

200 181 90 46 - 145Dichlorodifluoromethane

200 210 105 58 - 146Chloromethane

200 203 101 61 - 144Vinyl chloride

200 211 105 55 - 153Bromomethane

200 222 111 70 - 11612-Dibromo-3-Chloropropane

200 209 104 82 - 12212-Dichlorobenzene

200 190 95 69 - 147Trichlorofluoromethane

200 223 112 56 - 13911-Dichloroethene

200 211 106 80 - 12012-Dichloropropane

200 203 102 47 - 139112-Trichloro-122-trifluoroethane

200 250 125 45 - 156Acetone

200 218 109 58 - 139Carbon disulfide

200 220 110 50 - 151Methyl acetate

200 200 100 79 - 119Methylene Chloride

200 216 108 75 - 122trans-12-Dichloroethene

200 217 109 80 - 120Chlorodibromomethane

200 207 104 71 - 115Methyl tert-butyl ether

200 201 101 69 - 145Chloroethane

200 204 102 78 - 12211-Dichloroethane

200 211 106 80 - 120cis-12-Dichloroethene

200 214 107 65 - 1142-Butanone (MEK)

200 205 103 82 - 123Chloroform

200 206 103 79 - 126Ethylbenzene

200 208 104 58 - 133Cyclohexane

200 211 105 73 - 120Carbon tetrachloride

200 212 106 83 - 124Benzene

200 204 102 74 - 11812-Dichloroethane

200 212 106 78 - 119Trichloroethene

200 215 107 61 - 129Methylcyclohexane

200 214 107 79 - 119Dichlorobromomethane

200 216 108 80 - 120cis-13-Dichloropropene

200 214 107 53 - 1204-Methyl-2-pentanone (MIBK)

200 205 103 80 - 120Toluene

200 215 108 78 - 118trans-13-Dichloropropene

200 217 109 79 - 119112-Trichloroethane

200 210 105 68 - 139Tetrachloroethene

200 201 100 53 - 1212-Hexanone

200 215 107 78 - 11812-Dibromoethane

200 206 103 81 - 121Chlorobenzene

600 612 102 76 - 121Xylenes Total

200 207 104 69 - 112Styrene

200 217 109 73 - 123Bromoform

200 207 104 80 - 125Isopropylbenzene

200 210 105 74 - 1261122-Tetrachloroethane

200 204 102 81 - 12613-Dichlorobenzene

TestAmerica Edison 10162012Page 26 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10

Lab Control Sample - Batch 460-131656

Client Matrix

Lab Sample ID

Dilution

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08977d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5LCS 460-1316563

Analysis Date 10112012 2113

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Prep Date

Leach Date

10112012 2113

NA

Analyte QualLimit RecResultSpike Amount

200 204 102 83 - 12314-Dichlorobenzene

200 220 110 66 - 120124-Trichlorobenzene

Surrogate Rec Acceptance Limits

12-Dichloroethane-d4 (Surr) 96 70 - 130

4-Bromofluorobenzene 97 70 - 130

Toluene-d8 (Surr) 99 70 - 130

TestAmerica Edison 10162012Page 27 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Water

50

50

Client Matrix

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Client Matrix Water

e08985d

5 mL

5 mL

e08986d

5 mL

5 mL

Method 8260B

Preparation 5030B

VOAMS5

VOAMS5

460-45537-2

460-45537-2

MS Lab Sample ID

MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

10122012 0051

NA

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

10122012 0027

Analyte RPD LimitRPDLimit

Rec

MS MSD MS Qual MSD Qual

103 106 74 - 128 3 30111-Trichloroethane

87 90 46 - 145 4 30Dichlorodifluoromethane

102 101 58 - 146 0 30Chloromethane

104 105 61 - 144 0 30Vinyl chloride

107 105 55 - 153 2 30Bromomethane

121 121 70 - 116 0 30 F F12-Dibromo-3-Chloropropane

107 111 82 - 122 3 3012-Dichlorobenzene

121 100 69 - 147 19 30Trichlorofluoromethane

108 119 56 - 139 9 3011-Dichloroethene

111 110 80 - 120 0 3012-Dichloropropane

102 111 47 - 139 8 30112-Trichloro-122-trifluoroethane

99 101 45 - 156 2 30Acetone

113 119 58 - 139 5 30Carbon disulfide

100 101 50 - 151 1 30Methyl acetate

106 106 79 - 119 0 30Methylene Chloride

106 108 75 - 122 2 30trans-12-Dichloroethene

116 118 80 - 120 2 30Chlorodibromomethane

114 116 71 - 115 1 30 FMethyl tert-butyl ether

116 105 69 - 145 10 30Chloroethane

104 111 78 - 122 7 3011-Dichloroethane

105 109 80 - 120 4 30cis-12-Dichloroethene

111 114 65 - 114 3 302-Butanone (MEK)

108 113 82 - 123 4 30Chloroform

107 111 79 - 126 3 30Ethylbenzene

108 117 58 - 133 7 30Cyclohexane

105 110 73 - 120 5 30Carbon tetrachloride

106 114 83 - 124 7 30Benzene

107 109 74 - 118 2 3012-Dichloroethane

107 113 78 - 119 5 30Trichloroethene

115 121 61 - 129 5 30Methylcyclohexane

113 116 79 - 119 3 30Dichlorobromomethane

109 115 80 - 120 5 30cis-13-Dichloropropene

111 114 53 - 120 3 304-Methyl-2-pentanone (MIBK)

TestAmerica Edison 10162012Page 28 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Water

50

50

Client Matrix

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Client Matrix Water

e08985d

5 mL

5 mL

e08986d

5 mL

5 mL

Method 8260B

Preparation 5030B

VOAMS5

VOAMS5

460-45537-2

460-45537-2

MS Lab Sample ID

MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

10122012 0051

NA

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

10122012 0027

Analyte RPD LimitRPDLimit

Rec

MS MSD MS Qual MSD Qual

106 111 80 - 120 5 30Toluene

113 119 78 - 118 5 30 Ftrans-13-Dichloropropene

112 116 79 - 119 3 30112-Trichloroethane

110 116 68 - 139 5 30Tetrachloroethene

109 111 53 - 121 2 302-Hexanone

116 117 78 - 118 1 3012-Dibromoethane

107 111 81 - 121 3 30Chlorobenzene

106 110 76 - 121 3 30Xylenes Total

107 110 69 - 112 3 30Styrene

115 114 73 - 123 1 30Bromoform

107 111 80 - 125 4 30Isopropylbenzene

115 116 74 - 126 0 301122-Tetrachloroethane

106 110 81 - 126 4 3013-Dichlorobenzene

106 110 83 - 123 4 3014-Dichlorobenzene

110 119 66 - 120 8 30124-Trichlorobenzene

Surrogate Acceptance LimitsMS Rec MSD Rec

12-Dichloroethane-d4 (Surr) 96 96 70 - 130

4-Bromofluorobenzene 99 97 70 - 130

Toluene-d8 (Surr) 99 99 70 - 130

TestAmerica Edison 10162012Page 29 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10122012 0027 10122012 0051

Dilution Dilution50 50

Client Matrix Client Matrix Water

Method 8260B

Preparation 5030B

Units ugL460-45537-2 460-45537-2MS Lab Sample ID MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

Analysis Date

Prep Date

Leach Date

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

NA

Amount

Sample

Analyte ResultQual Amount ResultQual ResultQual

MS MSDMS Spike MSD Spike

0060 U 100 100 103 106111-Trichloroethane

022 U 100 100 865 896Dichlorodifluoromethane

010 U 100 100 102 101Chloromethane

014 U 100 100 104 105Vinyl chloride

018 U 100 100 107 105Bromomethane

040 U 100 100 121 121F F12-Dibromo-3-Chloropropane

021 U 100 100 107 11112-Dichlorobenzene

015 U 100 100 121 997Trichlorofluoromethane

0090 U 100 100 108 11911-Dichloroethene

0090 U 100 100 111 11012-Dichloropropane

0080 U 100 100 102 111112-Trichloro-122-trifluoroethane

27 U 100 100 986 101Acetone

013 U 100 100 113 119Carbon disulfide

034 U 100 100 100 101Methyl acetate

018 U 100 100 106 106Methylene Chloride

013 U 100 100 106 108trans-12-Dichloroethene

020 U 100 100 116 118Chlorodibromomethane

020 J 100 100 114 116 FMethyl tert-butyl ether

017 U 100 100 116 105Chloroethane

013 U 100 100 104 11111-Dichloroethane

018 U 100 100 105 109cis-12-Dichloroethene

23 U 100 100 111 1142-Butanone (MEK)

0080 U 100 100 108 113Chloroform

010 U 100 100 107 111Ethylbenzene

016 U 100 100 108 117Cyclohexane

0060 U 100 100 105 110Carbon tetrachloride

0080 U 100 100 106 114Benzene

019 U 100 100 107 10912-Dichloroethane

0090 U 100 100 107 113Trichloroethene

014 U 100 100 115 121Methylcyclohexane

012 U 100 100 113 116Dichlorobromomethane

018 U 100 100 109 115cis-13-Dichloropropene

099 U 100 100 111 1144-Methyl-2-pentanone (MIBK)

015 U 100 100 106 111Toluene

024 U 100 100 113 119 Ftrans-13-Dichloropropene

019 U 100 100 112 116112-Trichloroethane

010 U 100 100 110 116Tetrachloroethene

050 U 100 100 109 1112-Hexanone

028 U 100 100 116 11712-Dibromoethane

011 U 100 100 107 111Chlorobenzene

036 U 300 300 318 329Xylenes Total

012 U 100 100 107 110Styrene

019 U 100 100 115 114Bromoform

TestAmerica Edison 10162012Page 30 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10122012 0027 10122012 0051

Dilution Dilution50 50

Client Matrix Client Matrix Water

Method 8260B

Preparation 5030B

Units ugL460-45537-2 460-45537-2MS Lab Sample ID MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

Analysis Date

Prep Date

Leach Date

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

NA

Amount

Sample

Analyte ResultQual Amount ResultQual ResultQual

MS MSDMS Spike MSD Spike

0080 U 100 100 107 111Isopropylbenzene

016 U 100 100 115 1161122-Tetrachloroethane

014 U 100 100 106 11013-Dichlorobenzene

023 U 100 100 106 11014-Dichlorobenzene

034 U 100 100 110 119124-Trichlorobenzene

TestAmerica Edison 10162012Page 31 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-130997

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

vr479496d

1000 mL

5 mLUnits ugL

Method 8082

Preparation 3510C

PESTGC9MB 460-1309971-A

Analysis Date 10082012 2208

Analysis Batch

Prep Batch

Leach Batch NA

460-131137

460-130997

Prep Date Injection Volume

Leach Date

10082012 0755

NA PRIMARYColumn ID

Analyte RLMDLQualResult

013 U 050013PCB-1016

028 U 050028PCB-1221

012 U 050012PCB-1232

012 U 050012PCB-1242

024 U 050024PCB-1248

017 U 050017PCB-1254

015 U 050015PCB-1260

Surrogate Rec Acceptance Limits

DCB Decachlorobiphenyl 97 37 - 150

Surrogate Rec Acceptance Limits

DCB Decachlorobiphenyl 88 37 - 150

TestAmerica Edison 10162012Page 32 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Lab Control Sample

Lab Control Sample Duplicate Recovery Report - Batch 460-130997

10

10

Water

LCS Lab Sample ID

LCSD Lab Sample ID

Client Matrix

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

Client Matrix Water

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

ugL

vf479497d

1000 mL

5 mL

PRIMARY

vf479498d

1000 mL

5 mL

PRIMARY

ugL

Method 8082

Preparation 3510C

PESTGC9

PESTGC9

LCS 460-1309972-A

LCSD 460-1309973-A

Analysis Date

Prep Date

Leach Date

10082012 2224

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

Rec

103101 71 - 126 2 30PCB-1016

119115 73 - 130 4 30PCB-1260

Surrogate LCS Rec LCSD Rec Acceptance Limits

DCB Decachlorobiphenyl 91 108 37 - 150

Dilution

Dilution

Lab Control Sample

Lab Control Sample Duplicate Recovery Report - Batch 460-130997

10

10

Water

LCS Lab Sample ID

LCSD Lab Sample ID

Client Matrix

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

Client Matrix Water

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

ugL

vr479497d

1000 mL

5 mL

SECONDARY

vr479498d

1000 mL

5 mL

SECONDARY

ugL

Method 8082

Preparation 3510C

PESTGC9

PESTGC9

LCS 460-1309972-A

LCSD 460-1309973-A

Analysis Date

Prep Date

Leach Date

10082012 2224

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

Rec

9997 71 - 126 3 30PCB-1016

117111 73 - 130 5 30PCB-1260

Surrogate LCS Rec LCSD Rec Acceptance Limits

DCB Decachlorobiphenyl 84 99 37 - 150

TestAmerica Edison 10162012Page 33 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10082012 2224

Dilution Dilution10 10

Client Matrix

LCSD Lab Sample ID

Client Matrix Water

Laboratory Control

Laboratory Duplicate Data Report - Batch 460-130997

Method 8082

Preparation 3510C

Units ugLLCS 460-1309972-A LCSD 460-1309973-ALCS Lab Sample ID

Analysis Date

Prep Date

Leach Date

10082012 0755

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NANA

LCSD

ResultQual

LCS

ResultQual

LCSD Spike

Amount

LCS Spike

AmountAnalyte

516507500 500PCB-1016

595573500 500PCB-1260

Water

10082012 2224

Dilution Dilution10 10

Client Matrix

LCSD Lab Sample ID

Client Matrix Water

Laboratory Control

Laboratory Duplicate Data Report - Batch 460-130997

Method 8082

Preparation 3510C

Units ugLLCS 460-1309972-A LCSD 460-1309973-ALCS Lab Sample ID

Analysis Date

Prep Date

Leach Date

10082012 0755

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NANA

LCSD

ResultQual

LCS

ResultQual

LCSD Spike

Amount

LCS Spike

AmountAnalyte

497483500 500PCB-1016

583557500 500PCB-1260

TestAmerica Edison 10162012Page 34 of 323

DATA REPORTING QUALIFIERS

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Lab Section Qualifier Description

GCMS VOA

Indicates the analyte was analyzed for but not detectedU

MSMSD Recovery or RPD exceeds the control limitsF

Result is less than the RL but greater than or equal to the MDL and the

concentration is an approximate value

J

GC Semi VOA

Indicates the analyte was analyzed for but not detectedU

TestAmerica Edison 10162012Page 35 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

QC Association Summary

Lab Sample ID Client Sample ID Client Matrix Method Prep Batch

Report

Basis

GCMS VOA

Analysis Batch460-131656

Lab Control Sample Water 8260BLCS 460-1316563 T

Method Blank Water 8260BMB 460-1316564 T

WaterWC-17338-100512-MW14-MM-251 8260B460-45537-1 T

WaterWC-17338-100512-MW101-MM-252 8260B460-45537-2 T

Matrix Spike Water 8260B460-45537-2MS T

Matrix Spike Duplicate Water 8260B460-45537-2MSD T

WaterTB-17338-100512-253 8260B460-45537-3TB T

Report Basis

T = Total

GC Semi VOA

Prep Batch 460-130997

Lab Control Sample Water 3510CLCS 460-1309972-A T

Lab Control Sample Duplicate Water 3510CLCSD 460-1309973-A T

Method Blank Water 3510CMB 460-1309971-A T

WaterWC-17338-100512-MW14-MM-251 3510C460-45537-1 T

WaterWC-17338-100512-MW101-MM-252 3510C460-45537-2 T

Analysis Batch460-131137

Lab Control Sample Water 460-1309978082LCS 460-1309972-A T

Lab Control Sample Duplicate Water 460-1309978082LCSD 460-1309973-A T

Method Blank Water 460-1309978082MB 460-1309971-A T

Water 460-130997WC-17338-100512-MW14-MM-251 8082460-45537-1 T

Water 460-130997WC-17338-100512-MW101-MM-252 8082460-45537-2 T

Report Basis

T = Total

TestAmerica Edison

10162012Page 36 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Laboratory Chronicle

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1000

460-45537-1 WC-17338-100512-MW14-MM-251

P5030B 460-45537-A-1 460-131656 10112012 2341 KBTAL EDI1

A8260B 460-45537-A-1 460-131656 10112012 2341 KBTAL EDI1

P3510C 460-45537-E-1-B 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 460-45537-E-1-B 460-131137 460-130997 10092012 0029 CBBTAL EDI1

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 WC-17338-100512-MW101-MM-252

P5030B 460-45537-A-2 460-131656 10122012 0004 KBTAL EDI1

A8260B 460-45537-A-2 460-131656 10122012 0004 KBTAL EDI1

P3510C 460-45537-E-2-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 460-45537-E-2-A 460-131137 460-130997 10092012 0045 CBBTAL EDI1

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 MS WC-17338-100512-MW101-MM-252

P5030B 460-45537-C-2 MS 460-131656 10122012 0027 KBTAL EDI5

A8260B 460-45537-C-2 MS 460-131656 10122012 0027 KBTAL EDI5

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 MSD WC-17338-100512-MW101-MM-252

P5030B 460-45537-C-2 MSD 460-131656 10122012 0051 KBTAL EDI5

A8260B 460-45537-C-2 MSD 460-131656 10122012 0051 KBTAL EDI5

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 0000

460-45537-3 TB-17338-100512-253

P5030B 460-45537-A-3 460-131656 10112012 2317 KBTAL EDI1

A8260B 460-45537-A-3 460-131656 10112012 2317 KBTAL EDI1

A = Analytical Method P = Prep Method TestAmerica Edison

10162012Page 37 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Laboratory Chronicle

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

MB NA

P5030B MB 460-1316564 460-131656 10112012 2247 KBTAL EDI1

A8260B MB 460-1316564 460-131656 10112012 2247 KBTAL EDI1

P3510C MB 460-1309971-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 MB 460-1309971-A 460-131137 460-130997 10082012 2208 CBBTAL EDI1

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

LCS NA

P5030B LCS 460-1316563 460-131656 10112012 2113 KBTAL EDI1

A8260B LCS 460-1316563 460-131656 10112012 2113 KBTAL EDI1

P3510C LCS 460-1309972-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 LCS 460-1309972-A 460-131137 460-130997 10082012 2224 CBBTAL EDI1

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

LCSD NA

P3510C LCSD

460-1309973-A

460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 LCSD

460-1309973-A

460-131137 460-130997 10082012 2239 CBBTAL EDI1

Lab ReferencesTAL EDI = TestAmerica Edison

A = Analytical Method P = Prep Method TestAmerica Edison

10162012Page 38 of 323

Method 8260 DELVolatile Organics (GCMS) by Method

8260 (Delaware)

10162012Page 39 of 323

FORM II

GCMS VOA SURROGATE RECOVERY

Lab Name Job No 460-45537-1

SDG No

Matrix Water Level Low

TestAmerica Edison

GC Column (1) Rtx-VMS ID 018(mm)

Lab Sample IDClient Sample ID DCA TOL BFB

460-45537-1WC-17338-100512-MW14-MM-251

97 96 99

460-45537-2WC-17338-100512-MW101-MM-252

97 97 98

460-45537-3TB-17338-100512-253

97 97 99

MB 460-1316564 99 96 95

LCS 460-1316563 96 99 97

460-45537-2 MSWC-17338-100512-MW101-MM-252 MS

96 99 99

460-45537-2 MSDWC-17338-100512-MW101-MM-252 MSD

96 99 97

QC LIMITSQC LIMITSDCA = 12-Dichloroethane-d4 (Surr) 70-130

TOL = Toluene-d8 (Surr) 70-130

BFB = 4-Bromofluorobenzene 70-130

FORM II 8260B

Column to be used to flag recovery values

10162012Page 40 of 323

GCMS VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08977dWater

Lab ID LCS 460-1316563 Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

111-Trichloroethane 200 210 74-128105

Dichlorodifluoromethane 200 181 46-14590

Chloromethane 200 210 58-146105

Vinyl chloride 200 203 61-144101

Bromomethane 200 211 55-153105

12-Dibromo-3-Chloropropane 200 222 70-116111

12-Dichlorobenzene 200 209 82-122104

Trichlorofluoromethane 200 190 69-14795

11-Dichloroethene 200 223 56-139112

12-Dichloropropane 200 211 80-120106

112-Trichloro-122-trifluoroethane

200 203 47-139102

Acetone 200 250 45-156125

Carbon disulfide 200 218 58-139109

Methyl acetate 200 220 50-151110

Methylene Chloride 200 200 79-119100

trans-12-Dichloroethene 200 216 75-122108

Chlorodibromomethane 200 217 80-120109

Methyl tert-butyl ether 200 207 71-115104

Chloroethane 200 201 69-145101

11-Dichloroethane 200 204 78-122102

cis-12-Dichloroethene 200 211 80-120106

2-Butanone (MEK) 200 214 65-114107

Chloroform 200 205 82-123103

Ethylbenzene 200 206 79-126103

Cyclohexane 200 208 58-133104

Carbon tetrachloride 200 211 73-120105

Benzene 200 212 83-124106

12-Dichloroethane 200 204 74-118102

Trichloroethene 200 212 78-119106

Methylcyclohexane 200 215 61-129107

Dichlorobromomethane 200 214 79-119107

cis-13-Dichloropropene 200 216 80-120108

4-Methyl-2-pentanone (MIBK) 200 214 53-120107

Toluene 200 205 80-120103

trans-13-Dichloropropene 200 215 78-118108

112-Trichloroethane 200 217 79-119109

Tetrachloroethene 200 210 68-139105

2-Hexanone 200 201 53-121100

12-Dibromoethane 200 215 78-118107

Chlorobenzene 200 206 81-121103

Xylenes Total 600 612 76-121102

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 41 of 323

GCMS VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08977dWater

Lab ID LCS 460-1316563 Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

Styrene 200 207 69-112104

Bromoform 200 217 73-123109

Isopropylbenzene 200 207 80-125104

1122-Tetrachloroethane 200 210 74-126105

13-Dichlorobenzene 200 204 81-126102

14-Dichlorobenzene 200 204 83-123102

124-Trichlorobenzene 200 220 66-120110

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 42 of 323

GCMS VOA MATRIX SPIKE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08985dWater

Lab ID 460-45537-2 MS Client ID WC-17338-100512-MW101-MM-252 MS

TestAmerica Edison

LIMITS

COMPOUND

CONCENTRATION

REC

QC

REC

SAMPLE

CONCENTRATION

SPIKE

ADDED

(ugL) (ugL) (ugL)

MS MS

100 103 74-128111-Trichloroethane 1030060 U

100 865 46-145Dichlorodifluoromethane 87022 U

100 102 58-146Chloromethane 102010 U

100 104 61-144Vinyl chloride 104014 U

100 107 55-153Bromomethane 107018 U

100 121 70-11612-Dibromo-3-Chloropropane 121040 U F

100 107 82-12212-Dichlorobenzene 107021 U

100 121 69-147Trichlorofluoromethane 121015 U

100 108 56-13911-Dichloroethene 1080090 U

100 111 80-12012-Dichloropropane 1110090 U

100 102 47-139112-Trichloro-122-trifluoroethane

1020080 U

100 986 45-156Acetone 9927 U

100 113 58-139Carbon disulfide 113013 U

100 100 50-151Methyl acetate 100034 U

100 106 79-119Methylene Chloride 106018 U

100 106 75-122trans-12-Dichloroethene 106013 U

100 116 80-120Chlorodibromomethane 116020 U

100 114 71-115Methyl tert-butyl ether 114020 J

100 116 69-145Chloroethane 116017 U

100 104 78-12211-Dichloroethane 104013 U

100 105 80-120cis-12-Dichloroethene 105018 U

100 111 65-1142-Butanone (MEK) 11123 U

100 108 82-123Chloroform 1080080 U

100 107 79-126Ethylbenzene 107010 U

100 108 58-133Cyclohexane 108016 U

100 105 73-120Carbon tetrachloride 1050060 U

100 106 83-124Benzene 1060080 U

100 107 74-11812-Dichloroethane 107019 U

100 107 78-119Trichloroethene 1070090 U

100 115 61-129Methylcyclohexane 115014 U

100 113 79-119Dichlorobromomethane 113012 U

100 109 80-120cis-13-Dichloropropene 109018 U

100 111 53-1204-Methyl-2-pentanone (MIBK) 111099 U

100 106 80-120Toluene 106015 U

100 113 78-118trans-13-Dichloropropene 113024 U

100 112 79-119112-Trichloroethane 112019 U

100 110 68-139Tetrachloroethene 110010 U

100 109 53-1212-Hexanone 109050 U

100 116 78-11812-Dibromoethane 116028 U

100 107 81-121Chlorobenzene 107011 U

300 318 76-121Xylenes Total 106036 U

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 43 of 323

GCMS VOA MATRIX SPIKE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08985dWater

Lab ID 460-45537-2 MS Client ID WC-17338-100512-MW101-MM-252 MS

TestAmerica Edison

LIMITS

COMPOUND

CONCENTRATION

REC

QC

REC

SAMPLE

CONCENTRATION

SPIKE

ADDED

(ugL) (ugL) (ugL)

MS MS

100 107 69-112Styrene 107012 U

100 115 73-123Bromoform 115019 U

100 107 80-125Isopropylbenzene 1070080 U

100 115 74-1261122-Tetrachloroethane 115016 U

100 106 81-12613-Dichlorobenzene 106014 U

100 106 83-12314-Dichlorobenzene 106023 U

100 110 66-120124-Trichlorobenzene 110034 U

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 44 of 323

GCMS VOA MATRIX SPIKE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08986dWater

Lab ID 460-45537-2 MSD Client ID WC-17338-100512-MW101-MM-252

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

MSD MSD

100 106 30 74-128111-Trichloroethane 3106

100 896 30 46-145Dichlorodifluoromethane 490

100 101 30 58-146Chloromethane 0101

100 105 30 61-144Vinyl chloride 0105

100 105 30 55-153Bromomethane 2105

100 121 30 70-11612-Dibromo-3-Chloropropane 0121 F

100 111 30 82-12212-Dichlorobenzene 3111

100 997 30 69-147Trichlorofluoromethane 19100

100 119 30 56-13911-Dichloroethene 9119

100 110 30 80-12012-Dichloropropane 0110

100 111 30 47-139112-Trichloro-122-trifluoroethane

8111

100 101 30 45-156Acetone 2101

100 119 30 58-139Carbon disulfide 5119

100 101 30 50-151Methyl acetate 1101

100 106 30 79-119Methylene Chloride 0106

100 108 30 75-122trans-12-Dichloroethene 2108

100 118 30 80-120Chlorodibromomethane 2118

100 116 30 71-115Methyl tert-butyl ether 1116 F

100 105 30 69-145Chloroethane 10105

100 111 30 78-12211-Dichloroethane 7111

100 109 30 80-120cis-12-Dichloroethene 4109

100 114 30 65-1142-Butanone (MEK) 3114

100 113 30 82-123Chloroform 4113

100 111 30 79-126Ethylbenzene 3111

100 117 30 58-133Cyclohexane 7117

100 110 30 73-120Carbon tetrachloride 5110

100 114 30 83-124Benzene 7114

100 109 30 74-11812-Dichloroethane 2109

100 113 30 78-119Trichloroethene 5113

100 121 30 61-129Methylcyclohexane 5121

100 116 30 79-119Dichlorobromomethane 3116

100 115 30 80-120cis-13-Dichloropropene 5115

100 114 30 53-1204-Methyl-2-pentanone (MIBK) 3114

100 111 30 80-120Toluene 5111

100 119 30 78-118trans-13-Dichloropropene 5119 F

100 116 30 79-119112-Trichloroethane 3116

100 116 30 68-139Tetrachloroethene 5116

100 111 30 53-1212-Hexanone 2111

100 117 30 78-11812-Dibromoethane 1117

100 111 30 81-121Chlorobenzene 3111

300 329 30 76-121Xylenes Total 3110

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 45 of 323

GCMS VOA MATRIX SPIKE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08986dWater

Lab ID 460-45537-2 MSD Client ID WC-17338-100512-MW101-MM-252

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

MSD MSD

100 110 30 69-112Styrene 3110

100 114 30 73-123Bromoform 1114

100 111 30 80-125Isopropylbenzene 4111

100 116 30 74-1261122-Tetrachloroethane 0116

100 110 30 81-12613-Dichlorobenzene 4110

100 110 30 83-12314-Dichlorobenzene 4110

100 119 30 66-120124-Trichlorobenzene 8119

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 46 of 323

FORM IV

GCMS VOA METHOD BLANK SUMMARY

Lab Name

SDG No

Job No 460-45537-1TestAmerica Edison

Date Analyzed

GC Column ID

Instrument ID 10112012 2247

Rtx-VMS

NHeated Purge(YN)

VOAMS5

e08981dLab File ID Lab Sample ID MB 460-1316564

WaterMatrix

018(mm)

THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES

LAB SAMPLE ID

LAB

FILE ID DATE ANALYZEDCLIENT SAMPLE ID

10112012 2113e08977dLCS 460-1316563

10112012 2317e08982d460-45537-3TB-17338-100512-253

10112012 2341e08983d460-45537-1WC-17338-100512-MW14-MM-251

10122012 0004e08984d460-45537-2WC-17338-100512-MW101-MM-252

10122012 0027e08985d460-45537-2 MSWC-17338-100512-MW101-MM-252 MS

10122012 0051e08986d460-45537-2 MSDWC-17338-100512-MW101-MM-252 MSD

FORM IV 8260B

10162012Page 47 of 323

FORM V

BROMOFLUOROBENZENE (BFB)

Lab Name

SDG No

Job No 460-45537-1

Lab File ID

Instrument ID

e07834d

VOAMS5

09172012

0324

BFB Injection Date

BFB Injection Time

ME ION ABUNDANCE CRITERIA RELATIVEABUNDANCE

Analysis Batch No 128076

50 150 - 400 of mass 95 219

75 300 - 600 of mass 95 525

95 Base Peak 100 relative abundance 1000

96 50 - 90 of mass 95 64

173 Less than 20 of mass 174 00 (00)1

174 500 - 12000 of mass 95 796

175 50 - 90 of mass 174 66 (83)1

176 950 - 1010 of mass 174 761 (957)1

177 50 - 90 of mass 176 48 (63)2

1-Value is mass 174 2-Value is mass 176

THIS CHECK APPLIES TO THE FOLLOWING SAMPLES MS MSD BLANKS AND STANDARDS

GCMS VOA INSTRUMENT PERFORMANCE CHECK

TestAmerica Edison

CLIENT SAMPLE IDLAB

FILE IDLAB SAMPLE IDDATE

ANALYZEDTIME

ANALYZED

e07836d 09172012 0449IC 460-1280762

e07838d 09172012 0536IC 460-1280763

e07839d 09172012 0600ICIS 460-1280764

e07840d 09172012 0623IC 460-1280765

e07841d 09172012 0646IC 460-1280766

e07842d 09172012 0710IC 460-1280767

FORM V 8260B 10162012Page 48 of 323

FORM V

BROMOFLUOROBENZENE (BFB)

Lab Name

SDG No

Job No 460-45537-1

Lab File ID

Instrument ID

e08975d

VOAMS5

10112012

2008

BFB Injection Date

BFB Injection Time

ME ION ABUNDANCE CRITERIA RELATIVEABUNDANCE

Analysis Batch No 131656

50 150 - 400 of mass 95 218

75 300 - 600 of mass 95 518

95 Base Peak 100 relative abundance 1000

96 50 - 90 of mass 95 65

173 Less than 20 of mass 174 07 (07)1

174 500 - 12000 of mass 95 896

175 50 - 90 of mass 174 72 (80)1

176 950 - 1010 of mass 174 872 (973)1

177 50 - 90 of mass 176 53 (61)2

1-Value is mass 174 2-Value is mass 176

THIS CHECK APPLIES TO THE FOLLOWING SAMPLES MS MSD BLANKS AND STANDARDS

GCMS VOA INSTRUMENT PERFORMANCE CHECK

TestAmerica Edison

CLIENT SAMPLE IDLAB

FILE IDLAB SAMPLE IDDATE

ANALYZEDTIME

ANALYZED

e08976d 10112012 2050CCVIS 460-1316562

e08977d 10112012 2113LCS 460-1316563

e08981d 10112012 2247MB 460-1316564

TB-17338-100512-253 e08982d 10112012 2317460-45537-3

WC-17338-100512-MW14-MM-251

e08983d 10112012 2341460-45537-1

WC-17338-100512-MW101-MM-252

e08984d 10122012 0004460-45537-2

WC-17338-100512-MW101-MM-252 MS

e08985d 10122012 0027460-45537-2 MS

WC-17338-100512-MW101-MM-252 MSD

e08986d 10122012 0051460-45537-2 MSD

e08987d 10122012 0114CCV 460-13165610

FORM V 8260B 10162012Page 49 of 323

GCMS VOA INTERNAL STANDARD AREA AND RETENTION TIME SUMMARY

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVIS 460-1316562 Date Analyzed 10112012 2050

Lab File ID (Standard) e08976d

Instrument ID VOAMS5 GC Column Rtx-VMS ID 018(mm)

Heated Purge (YN) N

Calibration ID 17515

AREA RT AREA RT AREA RT

FB CBZ DCB

UPPER LIMIT

LOWER LIMIT

2625312

656328 578671

2314682

333917

1335668

360 695 10471224 HOUR STD

410

310

745

645

1097

997

1312656 1157341 667834

LAB SAMPLE ID CLIENT SAMPLE ID

LCS 460-1316563 1318918 1146590 683882 360 695 1047

MB 460-1316564 1238441 1084553 638826 360 695 1047

460-45537-3 TB-17338-100512-253 1280000 1135339 646856 359 695 1047

460-45537-1 WC-17338-100512-MW14-MM-251

1242225 1119807 641810 359 695 1047

460-45537-2 WC-17338-100512-MW101-MM-252

1247617 1105330 633816 360 695 1047

460-45537-2 MS WC-17338-100512-MW101-MM-252 MS

1234975 1102789 642491 359 695 1047

460-45537-2 MSD WC-17338-100512-MW101-MM-252 MSD

1296388 1119645 654839 360 695 1047

CCV 460-13165610 1274024 1125053 665092 359 695 1047

FB = Fluorobenzene

CBZ = Chlorobenzene-d5

DCB = 14-Dichlorobenzene-d4

Area Limit = 50-200 of internal standard area

RT Limit = plusmn 05 minutes of internal standard RT

Column used to flag values outside QC limits

FORM VIII 8260B

10162012Page 50 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014J1634-04-4 Methyl tert-butyl ether 017

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015J108-88-3 Toluene 017

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 51 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010J127-18-4 Tetrachloroethene 028

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

96 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 52 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 53 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08983d Report Date 12-Oct-2012 0041

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08983dLab Smp Id 460-45537-A-1 Client Smp ID WC-17338-100512-MW1Inj Date 11-OCT-2012 2341 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-1Misc Info 460-45537-A-1Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 8 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

28 MTBE 73 2016 2022 (0561) 2797 016909 017(a)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 375883 486598 49

52 Fluorobenzene 96 3595 3601 (1000) 1242225 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1240232 479413 48

66 Toluene 91 5162 5162 (0742) 4639 017041 017(a)

71 Tetrachloroethene 166 5582 5582 (0803) 1902 028047 028(a)

78 Chlorobenzene-d5 117 6954 6954 (1000) 1119807 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 516081 495668 50

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 641810 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 54 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

10162012Page 55 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

28 MTBE

10162012Page 56 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

66 Toluene

10162012Page 57 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

71 Tetrachloroethene

10162012Page 58 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014J1634-04-4 Methyl tert-butyl ether 020

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 59 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

98 70-130460-00-4 4-Bromofluorobenzene

97 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 60 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 61 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08984d Report Date 12-Oct-2012 1126

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08984dLab Smp Id 460-45537-A-2 Client Smp ID WC-17338-100512-MW1Inj Date 12-OCT-2012 0004 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-2Misc Info 460-45537-A-2Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 9 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

28 MTBE 73 2016 2022 (0561) 3378 020333 020(a)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 375158 483561 48

52 Fluorobenzene 96 3595 3601 (1000) 1247617 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1243750 487069 49

78 Chlorobenzene-d5 117 6954 6954 (1000) 1105330 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 506189 492299 49

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 633816 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 62 of 323

Data File e08984d

Date 12-OCT-2012 0004

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-2 Operator GCMS VOAMS5

10162012Page 63 of 323

Data File e08984d

Date 12-OCT-2012 0004

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-2 Operator GCMS VOAMS5

28 MTBE

10162012Page 64 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018J75-09-2 Methylene Chloride 074

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014U1634-04-4 Methyl tert-butyl ether 014

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080J67-66-3 Chloroform 0096

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 65 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

97 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 66 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 67 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08982d Report Date 12-Oct-2012 1126

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08982dLab Smp Id 460-45537-A-3 Client Smp ID TB-17338-100512-253Inj Date 11-OCT-2012 2317 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-3Misc Info 460-45537-A-3Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 7 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

22 Methylene Chloride 49 1864 1864 (0518) 6426 073512 074(a)

42 Chloroform 83 2839 2845 (0790) 973 009557 0096(aH)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 385354 484137 48

52 Fluorobenzene 96 3595 3601 (1000) 1280000 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1266759 482968 48

78 Chlorobenzene-d5 117 6954 6954 (1000) 1135339 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 518232 493851 49

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 646856 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

H - Operator selected an alternate compound hit

10162012Page 68 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

10162012Page 69 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

22 Methylene Chloride

10162012Page 70 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

42 Chloroform

10162012Page 71 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1280762 e07836d2Level IC 460-1280763 e07838d3Level ICIS 460-1280764 e07839d4Level IC 460-1280765 e07840d5Level IC 460-1280766 e07841d6Level IC 460-1280767 e07842d

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

Dichlorodifluoromethane 01877 01710 01761 01874 01774 Ave 6501572

01000 30001761

Chloromethane 04585 03624 03717 03896 03503 Ave 13403074

01000 30003733

Vinyl chloride 03440 02904 02965 03157 02914 Ave 10102532

01000 30002985

Bromomethane 01457 01433 01250 01279 01268 Ave 8301184

01000 30001312

Chloroethane 01177 01273 01133 01184 00992 Ave 14300838

01000 30001099

Trichlorofluoromethane 02861 02160 02403 02359 02461 Ave 9902285

01000 30002422

11-Dichloroethene 01607 01355 01549 01479 01528 Ave 5801456

01000 30001496

Carbon disulfide 07031 06470 06825 07347 07283 Ave 5906366

01000 30006887

112-Trichloro-122-trifluoroethane 01346 01631 01661 01849 01887 Ave 11601772

01000 30001691

Methylene Chloride 04479 03769 03581 03500 03182 Ave 14802947

01000 30003576

Acetone 00225 00193 00188 00182 00162 Ave 13800153

01000 30000184

trans-12-Dichloroethene 02047 01989 02141 02174 02016 Ave 4301946

01000 30002052

Methyl acetate 00482 00463 00420 00421 00402 Ave 9400371

01000 30000426

Methyl tert-butyl ether 07109 07281 06924 06817 06907 Ave 6505992

01000 30006838

11-Dichloroethane 04650 04524 04893 04673 04494 Ave 4604257

01000 30004582

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 72 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

cis-12-Dichloroethene 02536 02396 02453 02363 02237 Ave 5602184

01000 30002361

Cyclohexane 03116 04199 04030 04447 04640 Ave 13204438

01000 30004145

Chloroform 03895 04109 04030 04060 03948 Ave 2503851

01000 30003982

Carbon tetrachloride 02420 02373 02793 02813 02930 Ave 9102903

01000 30002705

111-Trichloroethane 03091 03114 03513 03424 03583 Ave 6403522

01000 30003375

2-Butanone (MEK) 00273 00279 00385 00372 00372 Ave 14900364

01000 30000341

Benzene 12012 12533 12592 12117 12284 Ave 8709836

01000 30011896

12-Dichloroethane 03398 03425 03293 03270 03193 Ave 3503124

01000 30003284

Methylcyclohexane 02272 03440 03287 03727 03690 Ave 16303532

01000 30003325

Trichloroethene 02571 02192 02414 02341 02365 Ave 5202426

01000 30002385

12-Dichloropropane 02758 02786 02804 02730 02724 Ave 1202733

01000 30002756

Dichlorobromomethane 03209 03160 03185 03141 03239 Ave 1303237

01000 30003195

cis-13-Dichloropropene 05043 05293 05370 05217 05393 Ave 3105530

01000 30005308

Toluene 13662 13454 14250 13844 13425 Ave 9510731

01000 30013228

Tetrachloroethene 02730 02844 03369 03253 03225 Ave 8303255

01000 30003113

4-Methyl-2-pentanone (MIBK) 03587 03603 03526 03550 03603 Ave 1603692

01000 30003593

trans-13-Dichloropropene 04563 04743 04806 04779 04910 Ave 3805114

01000 30004819

112-Trichloroethane 02303 02327 02287 02201 02185 Ave 2502280

01000 30002264

Chlorodibromomethane 03013 02986 03088 03052 03111 Ave 3003249

01000 30003083

12-Dibromoethane 02596 02708 02743 02671 02629 Ave 2002676

01000 30002670

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 73 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

2-Hexanone 02652 02737 02670 02679 02755 Ave 3202514

01000 30002668

Chlorobenzene 08958 08985 09292 09070 08727 Ave 4008261

01000 30008882

Ethylbenzene 04549 04523 04953 04866 04834 Ave 3704808

01000 30004756

m-Xylene amp p-Xylene 05967 05752 06297 06168 06094 Ave 6505224

01000 30005917

o-Xylene 05732 05675 06142 06014 05989 Ave 3205765

01000 30005886

Bromoform 02053 01991 02150 02194 02258 Ave 4902237

01000 30002147

Styrene 09657 09899 10525 10511 10477 Ave 6408917

01000 30009998

Isopropylbenzene 13314 13509 15606 15346 15340 Ave 10811764

01000 30014146

1122-Tetrachloroethane 06545 06405 06616 06489 06390 Ave 1706330

01000 30006462

13-Dichlorobenzene 12616 12687 13292 13133 12758 Ave 3012242

01000 30012788

14-Dichlorobenzene 13636 13114 13708 13534 13010 Ave 3412550

01000 30013259

12-Dichlorobenzene 12298 12143 12601 12232 11746 Ave 3211521

01000 30012090

12-Dibromo-3-Chloropropane 01290 01163 01082 01109 01042 Ave 7801095

01000 30001130

124-Trichlorobenzene 06538 06139 06311 06265 05725 Ave 5405732

01000 30006118

12-Dichloroethane-d4 (Surr) 02599 02736 02573 02553 02667 Ave 2802702

01000 30002638

Toluene-d8 (Surr) 11377 12027 11720 11573 11645 Ave 1811690

01000 30011672

4-Bromofluorobenzene 07799 08146 08086 08044 08193 Ave 1908206

01000 30008079

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 74 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1280762 e07836dLevel 2 IC 460-1280763 e07838dLevel 3 ICIS 460-1280764 e07839dLevel 4 IC 460-1280765 e07840dLevel 5 IC 460-1280766 e07841dLevel 6 IC 460-1280767 e07842d

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Dichlorodifluoromethane AveFB 8660 39416 167418 450014 17982634551928

100 500 200 500 200500

Chloromethane AveFB 21155 83523 353287 935453 35519068902969

100 500 200 500 200500

Vinyl chloride AveFB 15876 66919 281874 757876 29543837332518

100 500 200 500 200500

Bromomethane AveFB 6723 33032 118799 307121 12855673429373

100 500 200 500 200500

Chloroethane AveFB 5433 29332 107678 284219 10059762426216

100 500 200 500 200500

Trichlorofluoromethane AveFB 13203 49780 228376 566305 24953266618134

100 500 200 500 200500

11-Dichloroethene AveFB 7415 31234 147259 355088 15491024214942

100 500 200 500 200500

Carbon disulfide AveFB 32446 149121 648801 1763903 738404918433408

100 500 200 500 200500

112-Trichloro-122-trifluoroethane

AveFB 6213 37580 157867 443949 19130255130629

100 500 200 500 200500

Methylene Chloride AveFB 20667 86862 340378 840419 32256318533685

100 500 200 500 200500

Acetone AveFB 5188 13342 17849 43750 164598441742

500 150 200 500 200500

trans-12-Dichloroethene AveFB 9445 45844 203500 521911 20443355633771

100 500 200 500 200500

Methyl acetate AveFB 2222 10660 39926 101112 4077131074355

100 500 200 500 200500

Methyl tert-butyl ether AveFB 32806 167790 658123 1636664 700252217351574

100 500 200 500 200500

11-Dichloroethane AveFB 21457 104265 465144 1121930 455634112326764

100 500 200 500 200500

cis-12-Dichloroethene AveFB 11702 55218 233129 567238 22679686324299

100 500 200 500 200500

FORM VI 8260B 10162012Page 75 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Cyclohexane AveFB 14380 96765 383104 1067735 470410312852489

100 500 200 500 200500

Chloroform AveFB 17974 94697 383084 974788 400250611152231

100 500 200 500 200500

Carbon tetrachloride AveFB 11168 54679 265527 675330 29705928405131

100 500 200 500 200500

111-Trichloroethane AveFB 14264 71766 333961 821993 363312510199723

100 500 200 500 200500

2-Butanone (MEK) AveFB 6291 19260 36552 89217 3773171055008

500 150 200 500 200500

Benzene AveCBZ 45050 227079 968083 2380099 986355721876514

100 500 200 500 200500

12-Dichloroethane AveFB 15679 78926 312991 785178 32368389046377

100 500 200 500 200500

Methylcyclohexane AveFB 10486 79279 312424 894738 374094710227785

100 500 200 500 200500

Trichloroethene AveFB 11865 50527 229465 562086 23978387026524

100 500 200 500 200500

12-Dichloropropane AveFB 12728 64209 266559 655380 27621167913672

100 500 200 500 200500

Dichlorobromomethane AveFB 14807 72835 302742 754124 32836079374106

100 500 200 500 200500

cis-13-Dichloropropene AveCBZ 18914 95905 412847 1024782 433022112299317

100 500 200 500 200500

Toluene AveCBZ 51238 243768 1095520 2719268 1077972123868197

100 500 200 500 200500

Tetrachloroethene AveCBZ 10238 51530 258990 639002 25895417239654

100 500 200 500 200500

4-Methyl-2-pentanone (MIBK) AveCBZ 67258 195851 271059 697282 28927468212153

500 150 200 500 200500

trans-13-Dichloropropene AveCBZ 17115 85943 369516 938808 394242511373599

100 500 200 500 200500

112-Trichloroethane AveCBZ 8636 42154 175853 432262 17543015071317

100 500 200 500 200500

Chlorodibromomethane AveCBZ 11301 54107 237421 599464 24982697227226

100 500 200 500 200500

12-Dibromoethane AveCBZ 9735 49066 210900 524614 21107665952425

100 500 200 500 200500

2-Hexanone AveCBZ 49729 148758 205286 526223 22117155590902

500 150 200 500 200500

Chlorobenzene AveCBZ 33596 162793 714336 1781568 700752018374405

100 500 200 500 200500

FORM VI 8260B 10162012Page 76 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Ethylbenzene AveCBZ 17061 81955 380762 955894 388164310693410

100 500 200 500 200500

m-Xylene amp p-Xylene AveCBZ 44761 208423 968280 2423002 978688223238078

200 100 400 100 4001000

o-Xylene AveCBZ 21499 102832 472158 1181273 480921512821590

100 500 200 500 200500

Bromoform AveCBZ 7698 36074 165267 430943 18127954974461

100 500 200 500 200500

Styrene AveCBZ 36217 179367 809158 2064560 841264519831782

100 500 200 500 200500

Isopropylbenzene AveCBZ 49933 244766 1199765 3014281 1231710326165908

100 500 200 500 200500

1122-Tetrachloroethane AveDCB 13823 63947 277413 702309 28987687365342

100 500 200 500 200500

13-Dichlorobenzene AveDCB 26644 126663 557342 1421450 578731414243841

100 500 200 500 200500

14-Dichlorobenzene AveDCB 28798 130929 574816 1464915 590189114602396

100 500 200 500 200500

12-Dichlorobenzene AveDCB 25972 121236 528396 1324016 532862113405399

100 500 200 500 200500

12-Dibromo-3-Chloropropane AveDCB 2725 11615 45388 120062 4727441274610

100 500 200 500 200500

124-Trichlorobenzene AveDCB 13808 61295 264648 678119 25969596669727

100 500 200 500 200500

12-Dichloroethane-d4 (Surr) AveFB 599539 630441 611357 613057 676105782507

500 500 500 500 500500

Toluene-d8 (Surr) AveCBZ 2133452 2179204 2252606 2273339 23375152600040

500 500 500 500 500500

4-Bromofluorobenzene AveDCB 823604 813301 847619 870646 929176954872

500 500 500 500 500500

Curve Type LegendAve = Average ISTD

FORM VI 8260B 10162012Page 77 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07836d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07836dLab Smp Id IC-VMCAL1 Inj Date 17-SEP-2012 0449 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL1Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 2 Calibration Sample Level 1Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 8660 100000 11

3 Chloromethane 50 1004 1004 (0280) 21155 100000 12

4 Vinyl Chloride 62 1016 1016 (0283) 15876 100000 12

6 Bromomethane 94 1169 1169 (0326) 6723 100000 11

5 Chloroethane 64 1230 1230 (0343) 5433 100000 11

7 Trichlorofluoromethane 101 1291 1291 (0360) 13203 100000 12

14 Freon TF 101 1565 1565 (0436) 6213 100000 080(a)

15 11-Dichloroethene 96 1547 1547 (0431) 7415 100000 11

16 Acetone 58 1882 1882 (0524) 5188 500000 61

18 Carbon Disulfide 76 1559 1559 (0434) 32446 100000 10

27 Methyl Acetate 74 1955 1955 (0545) 2222 100000 11

22 Methylene Chloride 49 1851 1851 (0516) 20667 100000 12

28 MTBE 73 2016 2016 (0562) 32806 100000 10

25 trans-12-Dichloroethene 96 1937 1937 (0540) 9445 100000 100

30 11-Dichloroethane 63 2303 2303 (0642) 21457 100000 10

36 cis-12-Dichloroethene 96 2644 2644 (0737) 11702 100000 11

10162012Page 78 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07836d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0856) 6291 500000 40(a)

42 Chloroform 83 2839 2839 (0791) 17974 100000 098(a)

44 Cyclohexane 56 2778 2778 (0774) 14380 100000 075(a)

43 111-Trichloroethane 97 2973 2973 (0828) 14264 100000 092(a)

45 Carbon Tetrachloride 117 2924 2924 (0815) 11168 100000 089(a)

48 Benzene 78 3254 3254 (0468) 45050 100000 10

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 599539 500000 49

49 12-Dichloroethane 62 3412 3412 (0951) 15679 100000 10

52 Fluorobenzene 96 3589 3589 (1000) 2307227 500000

54 Trichloroethene 95 3735 3735 (1041) 11865 100000 11

56 Methyl cyclohexane 83 3723 3723 (1037) 10486 100000 068(a)

57 12-Dichloropropane 63 4192 4192 (1168) 12728 100000 10

68 Bromodichloromethane 83 4266 4266 (1189) 14807 100000 10

67 cis-13-Dichloropropene 75 4906 4906 (0706) 18914 100000 095(a)

70 4-Methyl-2-Pentanone 43 5625 5625 (0810) 67258 500000 50

$ 65 Toluene-d8 (SUR) 98 5101 5101 (0734) 2133452 500000 49

66 Toluene 91 5156 5156 (0742) 51238 100000 10

64 trans-13-Dichloropropene 75 5650 5650 (0813) 17115 100000 095(a)

69 112-Trichloroethane 83 5826 5826 (0839) 8636 100000 10

71 Tetrachloroethene 166 5582 5582 (0803) 10238 100000 088(a)

73 2-Hexanone 43 6674 6674 (0960) 49729 500000 50

74 Dibromochloromethane 129 6015 6015 (0866) 11301 100000 098(a)

77 12-Dibromoethane 107 6265 6265 (0902) 9735 100000 097(a)

78 Chlorobenzene-d5 117 6948 6948 (1000) 1875221 500000

79 Chlorobenzene 112 6972 6972 (1004) 33596 100000 10

81 Ethylbenzene 106 7064 7064 (1017) 17061 100000 096(a)

82 m+p-Xylene 106 7271 7271 (1046) 44761 200000 20

84 o-Xylene 106 7856 7856 (1131) 21499 100000 097(a)

85 Styrene 104 7942 7942 (1143) 36217 100000 096(a)

86 Bromoform 173 7911 7911 (1139) 7698 100000 096(a)

88 Isopropylbenzene 105 8344 8344 (1201) 49933 100000 094(a)

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 823604 500000 48

92 1122-Tetrachloroethane 83 9112 9112 (0871) 13823 100000 10

105 13-Dichlorobenzene 146 10332 10332 (0987) 26644 100000 099(a)

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1055978 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 28798 100000 10

111 12-Dichlorobenzene 146 11148 11148 (1065) 25972 100000 10(H)

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 2725 100000 11

114 124-Trichlorobenzene 180 12971 12971 (1239) 13808 100000 11

M 120 12-Dichloroethene (Total) 100 21147 200000 21

M 121 Xylene (Total) 100 66260 300000 30

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

H - Operator selected an alternate compound hit

10162012Page 79 of 323

Data File e07836d

Date 17-SEP-2012 0449

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL1 Operator GCMS VOAMS5

10162012Page 80 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07838d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07838dLab Smp Id IC-VMCAL2 Inj Date 17-SEP-2012 0536 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL2Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 4 Calibration Sample Level 2Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 39416 500000 48

3 Chloromethane 50 1016 1016 (0283) 83523 500000 48

4 Vinyl Chloride 62 1022 1022 (0285) 66919 500000 49

6 Bromomethane 94 1169 1169 (0326) 33032 500000 55

5 Chloroethane 64 1230 1230 (0343) 29332 500000 58

7 Trichlorofluoromethane 101 1291 1291 (0360) 49780 500000 45

14 Freon TF 101 1559 1559 (0434) 37580 500000 48

15 11-Dichloroethene 96 1541 1541 (0429) 31234 500000 45

16 Acetone 58 1894 1894 (0528) 13342 150000 16

18 Carbon Disulfide 76 1553 1553 (0433) 149121 500000 47

27 Methyl Acetate 74 1961 1961 (0546) 10660 500000 54

22 Methylene Chloride 49 1851 1851 (0516) 86862 500000 53

28 MTBE 73 2016 2016 (0562) 167790 500000 53

25 trans-12-Dichloroethene 96 1937 1937 (0540) 45844 500000 48

30 11-Dichloroethane 63 2296 2296 (0640) 104265 500000 49

36 cis-12-Dichloroethene 96 2644 2644 (0737) 55218 500000 51

10162012Page 81 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07838d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0857) 19260 150000 12

42 Chloroform 83 2839 2839 (0791) 94697 500000 52

44 Cyclohexane 56 2772 2772 (0772) 96765 500000 51

43 111-Trichloroethane 97 2973 2973 (0828) 71766 500000 46

45 Carbon Tetrachloride 117 2924 2924 (0815) 54679 500000 44

48 Benzene 78 3254 3254 (0468) 227079 500000 53

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 630441 500000 52

49 12-Dichloroethane 62 3412 3412 (0951) 78926 500000 52

52 Fluorobenzene 96 3589 3589 (1000) 2304638 500000

54 Trichloroethene 95 3735 3735 (1041) 50527 500000 46

56 Methyl cyclohexane 83 3717 3717 (1036) 79279 500000 52

57 12-Dichloropropane 63 4192 4192 (1168) 64209 500000 50

68 Bromodichloromethane 83 4272 4272 (1190) 72835 500000 49

67 cis-13-Dichloropropene 75 4906 4906 (0706) 95905 500000 50

70 4-Methyl-2-Pentanone 43 5625 5625 (0810) 195851 150000 15

$ 65 Toluene-d8 (SUR) 98 5101 5101 (0734) 2179204 500000 52

66 Toluene 91 5156 5156 (0742) 243768 500000 51

64 trans-13-Dichloropropene 75 5643 5643 (0812) 85943 500000 49

69 112-Trichloroethane 83 5820 5820 (0838) 42154 500000 51

71 Tetrachloroethene 166 5576 5576 (0803) 51530 500000 46

73 2-Hexanone 43 6680 6680 (0961) 148758 150000 15

74 Dibromochloromethane 129 6015 6015 (0866) 54107 500000 48

77 12-Dibromoethane 107 6259 6259 (0901) 49066 500000 51

78 Chlorobenzene-d5 117 6948 6948 (1000) 1811885 500000

79 Chlorobenzene 112 6972 6972 (1004) 162793 500000 50

81 Ethylbenzene 106 7058 7058 (1016) 81955 500000 48

82 m+p-Xylene 106 7271 7271 (1046) 208423 100000 97

84 o-Xylene 106 7856 7856 (1131) 102832 500000 48

85 Styrene 104 7942 7942 (1143) 179367 500000 50

86 Bromoform 173 7911 7911 (1139) 36074 500000 46

88 Isopropylbenzene 105 8344 8344 (1201) 244766 500000 48

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 813301 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 63947 500000 50

105 13-Dichlorobenzene 146 10325 10325 (0987) 126663 500000 50

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 998386 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 130929 500000 49

111 12-Dichlorobenzene 146 11148 11148 (1065) 121236 500000 50

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 11615 500000 51

114 124-Trichlorobenzene 180 12965 12965 (1239) 61295 500000 50

M 120 12-Dichloroethene (Total) 100 101062 100000 99

M 121 Xylene (Total) 100 311255 150000 14

10162012Page 82 of 323

Data File e07838d

Date 17-SEP-2012 0536

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL2 Operator GCMS VOAMS5

10162012Page 83 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07839d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07839dLab Smp Id ICIS-VMCAL3 Inj Date 17-SEP-2012 0600 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info ICIS-VMCAL3Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 5 Calibration Sample Level 3Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 167418 200000 20

3 Chloromethane 50 1016 1016 (0283) 353287 200000 20

4 Vinyl Chloride 62 1016 1016 (0283) 281874 200000 20

6 Bromomethane 94 1175 1175 (0327) 118799 200000 19

5 Chloroethane 64 1230 1230 (0343) 107678 200000 21

7 Trichlorofluoromethane 101 1291 1291 (0360) 228376 200000 20

14 Freon TF 101 1559 1559 (0434) 157867 200000 20

15 11-Dichloroethene 96 1540 1540 (0429) 147259 200000 21

16 Acetone 58 1888 1888 (0526) 17849 200000 20

18 Carbon Disulfide 76 1559 1559 (0434) 648801 200000 20

27 Methyl Acetate 74 1955 1955 (0545) 39926 200000 20

22 Methylene Chloride 49 1851 1851 (0516) 340378 200000 20

28 MTBE 73 2016 2016 (0562) 658123 200000 20

25 trans-12-Dichloroethene 96 1943 1943 (0541) 203500 200000 21

30 11-Dichloroethane 63 2303 2303 (0642) 465144 200000 21

36 cis-12-Dichloroethene 96 2644 2644 (0737) 233129 200000 21

10162012Page 84 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07839d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0856) 36552 200000 22

42 Chloroform 83 2839 2839 (0791) 383084 200000 20

44 Cyclohexane 56 2778 2778 (0774) 383104 200000 19

43 111-Trichloroethane 97 2973 2973 (0828) 333961 200000 21

45 Carbon Tetrachloride 117 2924 2924 (0815) 265527 200000 21

48 Benzene 78 3254 3254 (0468) 968083 200000 21

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 611357 500000 49

49 12-Dichloroethane 62 3412 3412 (0951) 312991 200000 20

52 Fluorobenzene 96 3589 3589 (1000) 2376396 500000

54 Trichloroethene 95 3735 3735 (1041) 229465 200000 20

56 Methyl cyclohexane 83 3723 3723 (1037) 312424 200000 20

57 12-Dichloropropane 63 4192 4192 (1168) 266559 200000 20

68 Bromodichloromethane 83 4266 4266 (1189) 302742 200000 20

67 cis-13-Dichloropropene 75 4906 4906 (0705) 412847 200000 20

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 271059 200000 20

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2252606 500000 50

66 Toluene 91 5156 5156 (0741) 1095520 200000 22

64 trans-13-Dichloropropene 75 5643 5643 (0812) 369516 200000 20

69 112-Trichloroethane 83 5820 5820 (0837) 175853 200000 20

71 Tetrachloroethene 166 5576 5576 (0802) 258990 200000 22

73 2-Hexanone 43 6680 6680 (0961) 205286 200000 20

74 Dibromochloromethane 129 6015 6015 (0865) 237421 200000 20

77 12-Dibromoethane 107 6259 6259 (0900) 210900 200000 20

78 Chlorobenzene-d5 117 6954 6954 (1000) 1921967 500000

79 Chlorobenzene 112 6972 6972 (1003) 714336 200000 21

81 Ethylbenzene 106 7064 7064 (1016) 380762 200000 21

82 m+p-Xylene 106 7277 7277 (1046) 968280 400000 42

84 o-Xylene 106 7856 7856 (1130) 472158 200000 21

85 Styrene 104 7942 7942 (1142) 809158 200000 21

86 Bromoform 173 7911 7911 (1138) 165267 200000 20

88 Isopropylbenzene 105 8344 8344 (1200) 1199765 200000 22

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 847619 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 277413 200000 20

105 13-Dichlorobenzene 146 10325 10325 (0987) 557342 200000 21

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1048295 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 574816 200000 21

111 12-Dichlorobenzene 146 11148 11148 (1065) 528396 200000 21

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 45388 200000 19

114 124-Trichlorobenzene 180 12965 12965 (1239) 264648 200000 21

M 120 12-Dichloroethene (Total) 100 436629 400000 42

M 121 Xylene (Total) 100 1440438 600000 63

10162012Page 85 of 323

Data File e07839d

Date 17-SEP-2012 0600

Client ID Instrument VOAMS5i

Sample Info ICIS-VMCAL3 Operator GCMS VOAMS5

10162012Page 86 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07840d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07840dLab Smp Id IC-VMCAL4 Inj Date 17-SEP-2012 0623 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL4Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 6 Calibration Sample Level 4Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 450014 500000 53

3 Chloromethane 50 1010 1010 (0281) 935453 500000 52

4 Vinyl Chloride 62 1016 1016 (0283) 757876 500000 53

6 Bromomethane 94 1175 1175 (0327) 307121 500000 49

5 Chloroethane 64 1230 1230 (0342) 284219 500000 54

7 Trichlorofluoromethane 101 1290 1290 (0359) 566305 500000 49

14 Freon TF 101 1565 1565 (0435) 443949 500000 55

15 11-Dichloroethene 96 1540 1540 (0428) 355088 500000 49

16 Acetone 58 1888 1888 (0525) 43750 500000 50

18 Carbon Disulfide 76 1559 1559 (0434) 1763903 500000 53

27 Methyl Acetate 74 1961 1961 (0546) 101112 500000 49

22 Methylene Chloride 49 1851 1851 (0515) 840419 500000 49

28 MTBE 73 2016 2016 (0561) 1636664 500000 50

25 trans-12-Dichloroethene 96 1943 1943 (0540) 521911 500000 53

30 11-Dichloroethane 63 2302 2302 (0640) 1121930 500000 51

36 cis-12-Dichloroethene 96 2644 2644 (0735) 567238 500000 50

10162012Page 87 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07840d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0854) 89217 500000 54

42 Chloroform 83 2839 2839 (0790) 974788 500000 51

44 Cyclohexane 56 2778 2778 (0773) 1067735 500000 54

43 111-Trichloroethane 97 2973 2973 (0827) 821993 500000 51

45 Carbon Tetrachloride 117 2924 2924 (0813) 675330 500000 52

48 Benzene 78 3254 3254 (0468) 2380099 500000 51

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0934) 613057 500000 48

49 12-Dichloroethane 62 3412 3412 (0949) 785178 500000 50

52 Fluorobenzene 96 3595 3595 (1000) 2400971 500000

54 Trichloroethene 95 3735 3735 (1039) 562086 500000 49

56 Methyl cyclohexane 83 3723 3723 (1036) 894738 500000 56

57 12-Dichloropropane 63 4192 4192 (1166) 655380 500000 50

68 Bromodichloromethane 83 4272 4272 (1188) 754124 500000 49

67 cis-13-Dichloropropene 75 4906 4906 (0705) 1024782 500000 49

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 697282 500000 49

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2273339 500000 50

66 Toluene 91 5162 5162 (0742) 2719268 500000 52

64 trans-13-Dichloropropene 75 5649 5649 (0812) 938808 500000 50

69 112-Trichloroethane 83 5820 5820 (0837) 432262 500000 49

71 Tetrachloroethene 166 5576 5576 (0802) 639002 500000 52

73 2-Hexanone 43 6680 6680 (0961) 526223 500000 50

74 Dibromochloromethane 129 6015 6015 (0865) 599464 500000 49

77 12-Dibromoethane 107 6259 6259 (0900) 524614 500000 50

78 Chlorobenzene-d5 117 6954 6954 (1000) 1964266 500000

79 Chlorobenzene 112 6972 6972 (1003) 1781568 500000 51

81 Ethylbenzene 106 7064 7064 (1016) 955894 500000 51

82 m+p-Xylene 106 7277 7277 (1046) 2423002 100000 100

84 o-Xylene 106 7862 7862 (1131) 1181273 500000 51

85 Styrene 104 7942 7942 (1142) 2064560 500000 52

86 Bromoform 173 7911 7911 (1138) 430943 500000 51

88 Isopropylbenzene 105 8350 8350 (1201) 3014281 500000 54

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 870646 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 702309 500000 50

105 13-Dichlorobenzene 146 10331 10331 (0987) 1421450 500000 51

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1082388 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 1464915 500000 51

111 12-Dichlorobenzene 146 11154 11154 (1066) 1324016 500000 50

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 120062 500000 49

114 124-Trichlorobenzene 180 12971 12971 (1239) 678119 500000 51

M 120 12-Dichloroethene (Total) 100 1089149 100000 100

M 121 Xylene (Total) 100 3604275 150000 160

10162012Page 88 of 323

Data File e07840d

Date 17-SEP-2012 0623

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL4 Operator GCMS VOAMS5

10162012Page 89 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07841d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07841dLab Smp Id IC-VMCAL5 Inj Date 17-SEP-2012 0646 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL5Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 7 Calibration Sample Level 5Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 1798263 200000 200

3 Chloromethane 50 1010 1010 (0281) 3551906 200000 190

4 Vinyl Chloride 62 1016 1016 (0283) 2954383 200000 200

6 Bromomethane 94 1175 1175 (0327) 1285567 200000 190

5 Chloroethane 64 1230 1230 (0342) 1005976 200000 180

7 Trichlorofluoromethane 101 1291 1291 (0359) 2495326 200000 200

14 Freon TF 101 1565 1565 (0435) 1913025 200000 220

15 11-Dichloroethene 96 1541 1541 (0429) 1549102 200000 200

16 Acetone 58 1894 1894 (0527) 164598 200000 180

18 Carbon Disulfide 76 1559 1559 (0434) 7384049 200000 210

27 Methyl Acetate 74 1961 1961 (0546) 407713 200000 190

22 Methylene Chloride 49 1851 1851 (0515) 3225631 200000 180

28 MTBE 73 2016 2016 (0561) 7002522 200000 200

25 trans-12-Dichloroethene 96 1943 1943 (0540) 2044335 200000 200

30 11-Dichloroethane 63 2303 2303 (0640) 4556341 200000 200

36 cis-12-Dichloroethene 96 2650 2650 (0737) 2267968 200000 190

10162012Page 90 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07841d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0854) 377317 200000 220

42 Chloroform 83 2839 2839 (0790) 4002506 200000 200

44 Cyclohexane 56 2784 2784 (0774) 4704103 200000 220

43 111-Trichloroethane 97 2979 2979 (0829) 3633125 200000 210

45 Carbon Tetrachloride 117 2930 2930 (0815) 2970592 200000 220

48 Benzene 78 3260 3260 (0468) 9863557 200000 210

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 676105 500000 50

49 12-Dichloroethane 62 3418 3418 (0951) 3236838 200000 190

52 Fluorobenzene 96 3595 3595 (1000) 2534623 500000

54 Trichloroethene 95 3741 3741 (1041) 2397838 200000 200

56 Methyl cyclohexane 83 3729 3729 (1037) 3740947 200000 220

57 12-Dichloropropane 63 4199 4199 (1168) 2762116 200000 200

68 Bromodichloromethane 83 4272 4272 (1188) 3283607 200000 200

67 cis-13-Dichloropropene 75 4912 4912 (0706) 4330221 200000 200

70 4-Methyl-2-Pentanone 43 5631 5631 (0809) 2892746 200000 200

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2337515 500000 50

66 Toluene 91 5162 5162 (0742) 10779721 200000 200

64 trans-13-Dichloropropene 75 5656 5656 (0813) 3942425 200000 200

69 112-Trichloroethane 83 5826 5826 (0837) 1754301 200000 190

71 Tetrachloroethene 166 5582 5582 (0802) 2589541 200000 210

73 2-Hexanone 43 6686 6686 (0961) 2211715 200000 210

74 Dibromochloromethane 129 6021 6021 (0865) 2498269 200000 200

77 12-Dibromoethane 107 6265 6265 (0900) 2110766 200000 200

78 Chlorobenzene-d5 117 6960 6960 (1000) 2007362 500000

79 Chlorobenzene 112 6978 6978 (1003) 7007520 200000 200

81 Ethylbenzene 106 7076 7076 (1017) 3881643 200000 200

82 m+p-Xylene 106 7289 7289 (1047) 9786882 400000 410

84 o-Xylene 106 7869 7869 (1131) 4809215 200000 200

85 Styrene 104 7954 7954 (1143) 8412645 200000 210

86 Bromoform 173 7923 7923 (1138) 1812795 200000 210

88 Isopropylbenzene 105 8356 8356 (1201) 12317103 200000 220(A)

$ 89 Bromofluorobenzene (SUR) 174 8716 8716 (0832) 929176 500000 51

92 1122-Tetrachloroethane 83 9124 9124 (0871) 2898768 200000 200

105 13-Dichlorobenzene 146 10344 10344 (0987) 5787314 200000 200

108 14-Dichlorobenzene-d4 152 10478 10478 (1000) 1134091 500000

109 14-Dichlorobenzene 146 10502 10502 (1002) 5901891 200000 200

111 12-Dichlorobenzene 146 11167 11167 (1066) 5328621 200000 190

112 12-Dibromo-3-chloropropane 75 12240 12240 (1168) 472744 200000 180

114 124-Trichlorobenzene 180 12971 12971 (1238) 2596959 200000 190

M 120 12-Dichloroethene (Total) 100 4312303 400000 380

M 121 Xylene (Total) 100 14596097 600000 620

QC Flag Legend

A - Target compound detected but quantitated amountexceeded maximum amount

10162012Page 91 of 323

Data File e07841d

Date 17-SEP-2012 0646

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL5 Operator GCMS VOAMS5

10162012Page 92 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07842d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07842dLab Smp Id IC-VMCAL6 Inj Date 17-SEP-2012 0710 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL6Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 8 Calibration Sample Level 6Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 4551928 500000 450

3 Chloromethane 50 1010 1010 (0280) 8902969 500000 410

4 Vinyl Chloride 62 1016 1016 (0282) 7332518 500000 420

6 Bromomethane 94 1175 1175 (0326) 3429373 500000 450

5 Chloroethane 64 1230 1230 (0341) 2426216 500000 380

7 Trichlorofluoromethane 101 1297 1297 (0360) 6618134 500000 470

14 Freon TF 101 1571 1571 (0436) 5130629 500000 520(A)

15 11-Dichloroethene 96 1547 1547 (0429) 4214942 500000 490

16 Acetone 58 1894 1894 (0526) 441742 500000 420

18 Carbon Disulfide 76 1559 1559 (0433) 18433408 500000 460

27 Methyl Acetate 74 1961 1961 (0545) 1074355 500000 440

22 Methylene Chloride 49 1851 1851 (0514) 8533685 500000 410

28 MTBE 73 2022 2022 (0562) 17351574 500000 440

25 trans-12-Dichloroethene 96 1943 1943 (0540) 5633771 500000 470

30 11-Dichloroethane 63 2302 2302 (0639) 12326764 500000 460

36 cis-12-Dichloroethene 96 2650 2650 (0736) 6324299 500000 460

10162012Page 93 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07842d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3083 3083 (0856) 1055008 500000 530(A)

42 Chloroform 83 2845 2845 (0790) 11152231 500000 480

44 Cyclohexane 56 2790 2790 (0775) 12852489 500000 540(A)

43 111-Trichloroethane 97 2985 2985 (0829) 10199723 500000 520(A)

45 Carbon Tetrachloride 117 2936 2936 (0815) 8405131 500000 540(A)

48 Benzene 78 3260 3260 (0468) 21876514 500000 410

$ 47 12-Dichloroethane-d4 (SUR) 65 3369 3369 (0936) 782507 500000 51

49 12-Dichloroethane 62 3424 3424 (0951) 9046377 500000 480

52 Fluorobenzene 96 3601 3601 (1000) 2895790 500000

54 Trichloroethene 95 3753 3753 (1042) 7026524 500000 510(A)

56 Methyl cyclohexane 83 3741 3741 (1039) 10227785 500000 530(A)

57 12-Dichloropropane 63 4205 4205 (1168) 7913672 500000 500

68 Bromodichloromethane 83 4284 4284 (1190) 9374106 500000 510(A)

67 cis-13-Dichloropropene 75 4924 4924 (0706) 12299317 500000 520(A)

70 4-Methyl-2-Pentanone 43 5649 5649 (0810) 8212153 500000 510(A)

$ 65 Toluene-d8 (SUR) 98 5113 5113 (0733) 2600040 500000 50

66 Toluene 91 5168 5168 (0741) 23868197 500000 400

64 trans-13-Dichloropropene 75 5668 5668 (0813) 11373599 500000 530(A)

69 112-Trichloroethane 83 5838 5838 (0837) 5071317 500000 500(A)

71 Tetrachloroethene 166 5594 5594 (0802) 7239654 500000 520(A)

73 2-Hexanone 43 6698 6698 (0961) 5590902 500000 470

74 Dibromochloromethane 129 6033 6033 (0865) 7227226 500000 530(A)

77 12-Dibromoethane 107 6277 6277 (0900) 5952425 500000 500(A)

78 Chlorobenzene-d5 117 6972 6972 (1000) 2224153 500000

79 Chlorobenzene 112 6997 6997 (1003) 18374405 500000 460

81 Ethylbenzene 106 7094 7094 (1017) 10693410 500000 500(A)

82 m+p-Xylene 106 7308 7308 (1048) 23238078 100000 880

84 o-Xylene 106 7887 7887 (1131) 12821590 500000 490

85 Styrene 104 7966 7966 (1143) 19831782 500000 440

86 Bromoform 173 7942 7942 (1139) 4974461 500000 520(A)

88 Isopropylbenzene 105 8368 8368 (1200) 26165908 500000 420(A)

$ 89 Bromofluorobenzene (SUR) 174 8728 8728 (0832) 954872 500000 51

92 1122-Tetrachloroethane 83 9143 9143 (0871) 7365342 500000 490

105 13-Dichlorobenzene 146 10362 10362 (0987) 14243841 500000 480

108 14-Dichlorobenzene-d4 152 10496 10496 (1000) 1163568 500000

109 14-Dichlorobenzene 146 10526 10526 (1003) 14602396 500000 470

111 12-Dichlorobenzene 146 11185 11185 (1066) 13405399 500000 480

112 12-Dibromo-3-chloropropane 75 12246 12246 (1167) 1274610 500000 480

114 124-Trichlorobenzene 180 12977 12977 (1236) 6669727 500000 470

M 120 12-Dichloroethene (Total) 100 11958070 100000 940

M 121 Xylene (Total) 100 36059668 150000 1400

QC Flag Legend

A - Target compound detected but quantitated amountexceeded maximum amount

10162012Page 94 of 323

Data File e07842d

Date 17-SEP-2012 0710

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL6 Operator GCMS VOAMS5

10162012Page 95 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10112012 2050

09172012 0449

09172012 0710

CCVIS 460-1316562

Rtx-VMS

TestAmerica Edison

Lab File ID e08976d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Dichlorodifluoromethane 0194701761 01000 221 200 105 250Ave

Chloromethane 0322303733 01000 173 200 -137 250Ave

Vinyl chloride 0274402985 01000 184 200 -81 250Ave

Bromomethane 0159401312 01000 243 200 215 250Ave

Chloroethane 0127501099 01000 232 200 160 250Ave

Trichlorofluoromethane 0296002422 01000 244 200 222 250Ave

11-Dichloroethene 0161001496 01000 215 200 76 250Ave

Carbon disulfide 0655806887 01000 190 200 -48 250Ave

112-Trichloro-122-trifluoroethane

0198901691 01000 235 200 176 250Ave

Methylene Chloride 0341503576 01000 191 200 -45 250Ave

Acetone 0021400184 01000 233 200 164 250Ave

trans-12-Dichloroethene 0208902052 01000 204 200 18 250Ave

Methyl acetate 0037700426 01000 177 200 -115 250Ave

Methyl tert-butyl ether 0665806838 01000 195 200 -26 250Ave

11-Dichloroethane 0443404582 01000 194 200 -32 250Ave

cis-12-Dichloroethene 0227602361 01000 193 200 -36 250Ave

Cyclohexane 0338904145 01000 163 200 -183 250Ave

Chloroform 0397703982 01000 200 200 -01 250Ave

Carbon tetrachloride 0281602705 01000 208 200 41 250Ave

111-Trichloroethane 0352303375 01000 209 200 44 250Ave

2-Butanone (MEK) 0035400341 01000 208 200 40 250Ave

Benzene 10301190 01000 173 200 -134 250Ave

12-Dichloroethane 0331603284 01000 202 200 10 250Ave

Methylcyclohexane 0280603325 01000 169 200 -156 250Ave

Trichloroethene 0228602385 01000 192 200 -41 250Ave

12-Dichloropropane 0242002756 01000 176 200 -122 250Ave

Dichlorobromomethane 0303603195 01000 190 200 -50 250Ave

cis-13-Dichloropropene 0438605308 01000 165 200 -174 250Ave

Toluene 12151323 01000 184 200 -81 250Ave

Tetrachloroethene 0302803113 01000 195 200 -27 250Ave

4-Methyl-2-pentanone (MIBK) 0273203593 01000 152 200 -240 250Ave

trans-13-Dichloropropene 0396604819 01000 165 200 -177 250Ave

112-Trichloroethane 0185102264 01000 164 200 -182 250Ave

Chlorodibromomethane 0265003083 01000 172 200 -141 250Ave

12-Dibromoethane 0231002670 01000 173 200 -135 250Ave

2-Hexanone 0209702668 01000 157 200 -214 250Ave

Chlorobenzene 0830208882 01000 187 200 -65 250Ave

Ethylbenzene 0437104756 01000 184 200 -81 250Ave

m-Xylene amp p-Xylene 0555805917 01000 376 400 -61 250Ave

o-Xylene 0545405886 01000 185 200 -73 250Ave

FORM VII 8260B

10162012Page 96 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10112012 2050

09172012 0449

09172012 0710

CCVIS 460-1316562

Rtx-VMS

TestAmerica Edison

Lab File ID e08976d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Bromoform 0188102147 01000 175 200 -124 250Ave

Styrene 092181000 01000 184 200 -78 250Ave

Isopropylbenzene 13421415 01000 190 200 -52 250Ave

1122-Tetrachloroethane 0512306462 01000 159 200 -207 250Ave

13-Dichlorobenzene 11861279 01000 186 200 -72 250Ave

14-Dichlorobenzene 12311326 01000 186 200 -72 250Ave

12-Dichlorobenzene 11211209 01000 185 200 -73 250Ave

12-Dibromo-3-Chloropropane 0086101130 01000 152 200 -238 250Ave

124-Trichlorobenzene 0630306118 01000 206 200 30 250Ave

12-Dichloroethane-d4 (Surr) 0310902638 01000 589 500 178 250Ave

Toluene-d8 (Surr) 11551167 01000 495 500 -11 250Ave

4-Bromofluorobenzene 0811108079 01000 502 500 04 250Ave

FORM VII 8260B

10162012Page 97 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08976d Report Date 11-Oct-2012 2130

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08976dLab Smp Id CCVIS Inj Date 11-OCT-2012 2050 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info CCVISMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 1 Continuing Calibration SampleDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0900 0900 (0250) 102235 200000 22

3 Chloromethane 50 1016 1016 (0282) 169224 200000 17

4 Vinyl Chloride 62 1028 1028 (0286) 144069 200000 18

6 Bromomethane 94 1181 1181 (0328) 83687 200000 24

5 Chloroethane 64 1242 1242 (0345) 66969 200000 23

7 Trichlorofluoromethane 101 1303 1303 (0362) 155393 200000 24

14 Freon TF 101 1577 1577 (0438) 104446 200000 24

15 11-Dichloroethene 96 1553 1553 (0431) 84531 200000 22

16 Acetone 58 1894 1894 (0526) 11228 200000 23

18 Carbon Disulfide 76 1571 1571 (0436) 344348 200000 19

27 Methyl Acetate 74 1967 1967 (0546) 19813 200000 18

22 Methylene Chloride 49 1864 1864 (0518) 179288 200000 19

28 MTBE 73 2022 2022 (0562) 349596 200000 19

25 trans-12-Dichloroethene 96 1949 1949 (0541) 109681 200000 20

30 11-Dichloroethane 63 2309 2309 (0641) 232818 200000 19

36 cis-12-Dichloroethene 96 2656 2656 (0738) 119502 200000 19

10162012Page 98 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08976d Report Date 11-Oct-2012 2130

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0854) 18598 200000 21

42 Chloroform 83 2845 2845 (0790) 208815 200000 20

44 Cyclohexane 56 2784 2784 (0773) 177923 200000 16

43 111-Trichloroethane 97 2985 2985 (0829) 185002 200000 21

45 Carbon Tetrachloride 117 2937 2937 (0815) 147853 200000 21

48 Benzene 78 3260 3260 (0469) 476925 200000 17

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0934) 408134 500000 59

49 12-Dichloroethane 62 3418 3418 (0949) 174132 200000 20

52 Fluorobenzene 96 3601 3601 (1000) 1312656 500000

54 Trichloroethene 95 3741 3741 (1039) 120041 200000 19

56 Methyl cyclohexane 83 3729 3729 (1036) 147336 200000 17

57 12-Dichloropropane 63 4199 4199 (1166) 127078 200000 18

68 Bromodichloromethane 83 4272 4272 (1186) 159386 200000 19

67 cis-13-Dichloropropene 75 4912 4912 (0706) 203059 200000 16

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 126467 200000 15

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1336847 500000 49

66 Toluene 91 5162 5162 (0742) 562689 200000 18

64 trans-13-Dichloropropene 75 5649 5649 (0812) 183587 200000 16

69 112-Trichloroethane 83 5820 5820 (0837) 85707 200000 16

71 Tetrachloroethene 166 5582 5582 (0803) 140177 200000 19

73 2-Hexanone 43 6680 6680 (0961) 97080 200000 16

74 Dibromochloromethane 129 6021 6021 (0866) 122657 200000 17

77 12-Dibromoethane 107 6265 6265 (0901) 106920 200000 17

78 Chlorobenzene-d5 117 6954 6954 (1000) 1157341 500000

79 Chlorobenzene 112 6972 6972 (1003) 384334 200000 19

81 Ethylbenzene 106 7064 7064 (1016) 202362 200000 18

82 m+p-Xylene 106 7277 7277 (1046) 514606 400000 38

84 o-Xylene 106 7862 7862 (1131) 252476 200000 18

85 Styrene 104 7942 7942 (1142) 426740 200000 18

86 Bromoform 173 7911 7911 (1138) 87078 200000 18

88 Isopropylbenzene 105 8350 8350 (1201) 621124 200000 19

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 541700 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 136860 200000 16

105 13-Dichlorobenzene 146 10331 10331 (0987) 316835 200000 18

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 667834 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 328709 200000 18

111 12-Dichlorobenzene 146 11148 11148 (1065) 299393 200000 18

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 23001 200000 15

114 124-Trichlorobenzene 180 12977 12977 (1240) 168371 200000 21

M 120 12-Dichloroethene (Total) 100 229183 400000 40

M 121 Xylene (Total) 100 767082 600000 56

10162012Page 99 of 323

Data File e08976d

Date 11-OCT-2012 2050

Client ID Instrument VOAMS5i

Sample Info CCVIS Operator GCMS VOAMS5

10162012Page 100 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10122012 0114

09172012 0449

09172012 0710

CCV 460-13165610

Rtx-VMS

TestAmerica Edison

Lab File ID e08987d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Dichlorodifluoromethane 0166601761 01000 189 200 -54 250Ave

Chloromethane 0311403733 01000 167 200 -166 250Ave

Vinyl chloride 0256002985 01000 172 200 -142 250Ave

Bromomethane 0162301312 01000 247 200 237 250Ave

Chloroethane 0127201099 01000 231 200 157 250Ave

Trichlorofluoromethane 0257102422 01000 212 200 62 250Ave

11-Dichloroethene 0184901496 01000 247 200 236 250Ave

112-Trichloro-122-trifluoroethane

0225501691 01000 267 200 334 250Ave

Carbon disulfide 0788506887 01000 229 200 145 250Ave

Methylene Chloride 0351303576 01000 196 200 -18 250Ave

Acetone 0022000184 01000 239 200 197 250Ave

trans-12-Dichloroethene 0232002052 01000 226 200 130 250Ave

Methyl acetate 0048700426 01000 228 200 141 250Ave

Methyl tert-butyl ether 0769506838 01000 225 200 125 250Ave

11-Dichloroethane 0469804582 01000 205 200 25 250Ave

cis-12-Dichloroethene 0240902361 01000 204 200 20 250Ave

Cyclohexane 0384004145 01000 185 200 -74 250Ave

Chloroform 0438203982 01000 220 200 100 250Ave

Carbon tetrachloride 0291802705 01000 216 200 79 250Ave

111-Trichloroethane 0362803375 01000 215 200 75 250Ave

2-Butanone (MEK) 0042500341 01000 250 200 248 250Ave

Benzene 11151190 01000 188 200 -62 250Ave

12-Dichloroethane 0359603284 01000 219 200 95 250Ave

Methylcyclohexane 0344803325 01000 207 200 37 250Ave

Trichloroethene 0248302385 01000 208 200 41 250Ave

12-Dichloropropane 0265202756 01000 192 200 -38 250Ave

Dichlorobromomethane 0339803195 01000 213 200 63 250Ave

cis-13-Dichloropropene 0490405308 01000 185 200 -76 250Ave

Toluene 12801323 01000 194 200 -32 250Ave

Tetrachloroethene 0323103113 01000 208 200 38 250Ave

4-Methyl-2-pentanone (MIBK) 0319703593 01000 178 200 -110 250Ave

trans-13-Dichloropropene 0454104819 01000 188 200 -58 250Ave

112-Trichloroethane 0212502264 01000 188 200 -61 250Ave

Chlorodibromomethane 0306403083 01000 199 200 -06 250Ave

12-Dibromoethane 0261302670 01000 196 200 -22 250Ave

2-Hexanone 0243802668 01000 183 200 -86 250Ave

Chlorobenzene 0879308882 01000 198 200 -10 250Ave

Ethylbenzene 0463104756 01000 195 200 -26 250Ave

m-Xylene amp p-Xylene 0587505917 01000 397 400 -07 250Ave

o-Xylene 0578505886 01000 197 200 -17 250Ave

FORM VII 8260B

10162012Page 101 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10122012 0114

09172012 0449

09172012 0710

CCV 460-13165610

Rtx-VMS

TestAmerica Edison

Lab File ID e08987d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Bromoform 0223102147 01000 208 200 39 250Ave

Styrene 099051000 01000 198 200 -09 250Ave

Isopropylbenzene 14391415 01000 203 200 17 250Ave

1122-Tetrachloroethane 0579606462 01000 179 200 -103 250Ave

13-Dichlorobenzene 12591279 01000 197 200 -15 250Ave

14-Dichlorobenzene 13061326 01000 197 200 -15 250Ave

12-Dichlorobenzene 12151209 01000 201 200 05 250Ave

12-Dibromo-3-Chloropropane 0102901130 01000 182 200 -90 250Ave

124-Trichlorobenzene 0743906118 01000 243 200 216 250Ave

12-Dichloroethane-d4 (Surr) 0320902638 01000 608 500 216 250Ave

Toluene-d8 (Surr) 11471167 01000 491 500 -18 250Ave

4-Bromofluorobenzene 0806308079 01000 499 500 -02 250Ave

FORM VII 8260B

10162012Page 102 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12abe08987d Report Date 12-Oct-2012 0132

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12abe08987dLab Smp Id CCV Inj Date 12-OCT-2012 0114 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info CCVMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12ab8260DE_09mMeth Date 12-Oct-2012 0132 ken Quant Type ISTDCal Date 12-OCT-2012 0114 Cal File e08987dAls bottle 12 Continuing Calibration SampleDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0894 (0249) 84911 200000 19

3 Chloromethane 50 1016 1016 (0283) 158694 200000 17

4 Vinyl Chloride 62 1022 1022 (0284) 130464 200000 17

6 Bromomethane 94 1181 1181 (0328) 82695 200000 25

5 Chloroethane 64 1236 1236 (0344) 64840 200000 23

7 Trichlorofluoromethane 101 1297 1297 (0361) 131020 200000 21

14 Freon TF 101 1565 1565 (0435) 114931 200000 27

15 11-Dichloroethene 96 1547 1547 (0430) 94244 200000 25

16 Acetone 58 1894 1894 (0527) 11208 200000 24

18 Carbon Disulfide 76 1565 1565 (0435) 401807 200000 23

27 Methyl Acetate 74 1961 1961 (0546) 24794 200000 23

22 Methylene Chloride 49 1857 1857 (0517) 179010 200000 20

28 MTBE 73 2022 2022 (0562) 392131 200000 22

25 trans-12-Dichloroethene 96 1943 1943 (0540) 118223 200000 23

30 11-Dichloroethane 63 2302 2302 (0640) 239419 200000 20

36 cis-12-Dichloroethene 96 2650 2650 (0737) 122782 200000 20

10162012Page 103 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12abe08987d Report Date 12-Oct-2012 0132

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0856) 21666 200000 25

42 Chloroform 83 2845 2845 (0791) 223324 200000 22

44 Cyclohexane 56 2784 2784 (0774) 195679 200000 18

43 111-Trichloroethane 97 2979 2979 (0829) 184861 200000 21

45 Carbon Tetrachloride 117 2930 2930 (0815) 148689 200000 22

48 Benzene 78 3260 3260 (0469) 501947 200000 19

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 408924 500000 61

49 12-Dichloroethane 62 3418 3418 (0951) 183231 200000 22

52 Fluorobenzene 96 3595 3595 (1000) 1274024 500000

54 Trichloroethene 95 3741 3741 (1041) 126518 200000 21

56 Methyl cyclohexane 83 3723 3723 (1036) 175700 200000 21

57 12-Dichloropropane 63 4192 4192 (1166) 135130 200000 19

68 Bromodichloromethane 83 4272 4272 (1188) 173147 200000 21

67 cis-13-Dichloropropene 75 4906 4906 (0705) 220680 200000 18

70 4-Methyl-2-Pentanone 43 5631 5631 (0810) 143892 200000 18

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1290179 500000 49

66 Toluene 91 5162 5162 (0742) 576151 200000 19

64 trans-13-Dichloropropene 75 5649 5649 (0812) 204342 200000 19

69 112-Trichloroethane 83 5820 5820 (0837) 95620 200000 19

71 Tetrachloroethene 166 5582 5582 (0803) 145404 200000 21

73 2-Hexanone 43 6680 6680 (0961) 109697 200000 18

74 Dibromochloromethane 129 6015 6015 (0865) 137888 200000 20

77 12-Dibromoethane 107 6265 6265 (0901) 117575 200000 20

78 Chlorobenzene-d5 117 6954 6954 (1000) 1125053 500000

79 Chlorobenzene 112 6972 6972 (1003) 395719 200000 20

81 Ethylbenzene 106 7064 7064 (1016) 208414 200000 19

82 m+p-Xylene 106 7277 7277 (1046) 528781 400000 40

84 o-Xylene 106 7856 7856 (1130) 260320 200000 20

85 Styrene 104 7942 7942 (1142) 445737 200000 20

86 Bromoform 173 7917 7917 (1139) 100375 200000 21

88 Isopropylbenzene 105 8344 8344 (1200) 647568 200000 20

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 536325 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 154190 200000 18

105 13-Dichlorobenzene 146 10331 10331 (0987) 335032 200000 20

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 665092 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 347387 200000 20

111 12-Dichlorobenzene 146 11148 11148 (1065) 323155 200000 20

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 27376 200000 18

114 124-Trichlorobenzene 180 12977 12977 (1240) 197894 200000 24

M 120 12-Dichloroethene (Total) 100 241005 400000 43

M 121 Xylene (Total) 100 789101 600000 59

10162012Page 104 of 323

Data File e08987d

Date 12-OCT-2012 0114

Client ID Instrument VOAMS5i

Sample Info CCV Operator GCMS VOAMS5

10162012Page 105 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07834d Report Date 17-Sep-2012 0605

TestAmerica

Data file chemVOAMS5i8260DE09-17-1217sep12be07834dLab Smp Id BFB Inj Date 17-SEP-2012 0324 Operator VOAMS 1 Inst ID VOAMS5iSmp Info BFBMisc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12bBFBDELmMeth Date 27-Feb-2012 1508 sylvanus Quant Type ISTDCal Date Cal File Als bottle 2 QC Sample BFBDil Factor 100000 Integrator HP RTE Compound Sublist allsubTarget Version 350 Sample Matrix WATERProcessing Host hpd2

Concentration Formula Amt DF Uf Vf VI CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorUf 100000 ng unit correction factorVf 100000 Volumetric correction factorVI 100000 Injection Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT (REL RT) MASS RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ==== ======== ======= ======= ============ =====

1 BFB CAS 460-00-4

2352 2600 (0000) 95 195072 000- 10000 10000

2352 2600 (0000) 50 42624 1500- 4000 2185

2352 2600 (0000) 75 102376 3000- 6000 5248

2352 2600 (0000) 96 12530 500- 900 642

2352 2600 (0000) 173 0 000- 200 000

2352 2600 (0000) 174 155200 5000- 10000 7956

2352 2600 (0000) 175 12902 500- 900 831

2352 2600 (0000) 176 148480 9500- 10100 9567

2352 2600 (0000) 177 9343 500- 900 629

-------------------------------------------------------------------------------

10162012Page 106 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

10162012Page 107 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

1 BFB

RELATIVE me ION ABUNDANCE CRITERIA ABUNDANCE

+-----+------------------------------------------+---------------------+| | | || 95 | Base Peak 100 relative abundance | 10000 || 50 | 1500 - 4000 of mass 95 | 2185 || 75 | 3000 - 6000 of mass 95 | 5248 || 96 | 500 - 900 of mass 95 | 642 || 173 | Less than 200 of mass 174 | 000 ( 000) || 174 | 5000 - 10000 of mass 95 | 7956 || 175 | 500 - 900 of mass 174 | 661 ( 831) || 176 | 9500 - 10100 of mass 174 | 7612 ( 9567) || 177 | 500 - 900 of mass 176 | 479 ( 629) |+-----+------------------------------------------+---------------------+

10162012Page 108 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

Data File chemVOAMS5i8260DE09-17-1217sep12be07834dSpectrum Avg Scans 50-52 ( 235) Background Scan 46

Location of Maximum 9500Number of points 151

mz Y mz Y mz Y mz Y+------------------+------------------+------------------+------------------+| 3500 53 | 7700 1350 | 12300 88 | 17700 9343 || 3600 1914 | 7800 695 | 12400 252 | 17800 381 || 3700 12535 | 7900 5782 | 12500 148 | 18000 35 || 3800 10760 | 8000 1455 | 12700 282 | 18300 181 || 3900 3962 | 8100 5745 | 12800 338 | 18600 248 |+------------------+------------------+------------------+------------------+| 4100 387 | 8200 905 | 12900 75 | 18700 80 || 4400 707 | 8300 42 | 13000 926 | 18800 162 || 4500 1464 | 8500 229 | 13100 166 | 18900 142 || 4600 281 | 8600 239 | 13200 7 | 19100 151 || 4700 3334 | 8700 7427 | 13400 27 | 19200 54 |+------------------+------------------+------------------+------------------+| 4800 1491 | 8800 7774 | 13700 332 | 19300 44 || 4900 8401 | 9100 1022 | 13800 172 | 19400 110 || 5000 42624 | 9200 5845 | 14000 185 | 19600 46 || 5100 13346 | 9300 8046 | 14100 1957 | 19800 171 || 5200 539 | 9400 21672 | 14200 53 | 20000 162 |+------------------+------------------+------------------+------------------+| 5300 13 | 9500 195072 | 14300 1698 | 20200 62 || 5400 14 | 9600 12530 | 14400 295 | 20300 48 || 5500 230 | 9700 551 | 14500 186 | 20400 104 || 5600 3600 | 9900 79 | 14600 115 | 20500 34 || 5700 5500 | 10000 36 | 14700 156 | 20700 223 |+------------------+------------------+------------------+------------------+| 5800 113 | 10100 136 | 14800 465 | 20900 81 || 5900 106 | 10200 36 | 14900 118 | 21500 80 || 6000 1861 | 10300 237 | 15000 105 | 21900 89 || 6100 10125 | 10400 905 | 15300 459 | 22000 60 || 6200 9219 | 10500 514 | 15400 192 | 22600 84 |+------------------+------------------+------------------+------------------+| 6300 7541 | 10600 1054 | 15700 390 | 23000 188 || 6400 270 | 10700 304 | 16000 378 | 23100 74 || 6500 625 | 11000 398 | 16100 530 | 23500 107 || 6600 51 | 11100 151 | 16400 54 | 23900 43 || 6700 378 | 11200 121 | 16700 172 | 24600 123 |+------------------+------------------+------------------+------------------+| 6800 20496 | 11300 247 | 16800 205 | 24700 37 || 6900 19976 | 11500 421 | 16900 243 | 25000 57 || 7000 1570 | 11600 358 | 17000 351 | 25200 33 || 7200 740 | 11700 1343 | 17100 439 | 25500 46 || 7300 9006 | 11800 855 | 17200 227 | 26200 43 |+------------------+------------------+------------------+------------------+| 7400 34320 | 11900 733 | 17400 155200 | 26400 63 || 7500 102376 | 12100 68 | 17500 12902 | 26500 45 || 7600 8204 | 12200 77 | 17600 148480 | |+------------------+------------------+------------------+------------------+

10162012Page 109 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08975d Report Date 11-Oct-2012 2012

TestAmerica

Data file chemVOAMS5i8260DE09-17-1211oct12be08975dLab Smp Id BFB Inj Date 11-OCT-2012 2008 Operator VOAMS 1 Inst ID VOAMS5iSmp Info BFBMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12bBFBDELmMeth Date 27-Feb-2012 1508 sylvanus Quant Type ISTDCal Date Cal File Als bottle 2 QC Sample BFBDil Factor 100000 Integrator HP RTE Compound Sublist allsubTarget Version 350 Sample Matrix WATERProcessing Host hpd2

Concentration Formula Amt DF Uf Vf VI CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorUf 100000 ng unit correction factorVf 100000 Volumetric correction factorVI 100000 Injection Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT (REL RT) MASS RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ==== ======== ======= ======= ============ =====

1 BFB CAS 460-00-4

2352 2600 (0000) 95 135522 000- 10000 10000

2352 2600 (0000) 50 29541 1500- 4000 2180

2352 2600 (0000) 75 70179 3000- 6000 5178

2352 2600 (0000) 96 8846 500- 900 653

2352 2600 (0000) 173 896 000- 200 074

2352 2600 (0000) 174 121433 5000- 10000 8960

2352 2600 (0000) 175 9704 500- 900 799

2352 2600 (0000) 176 118148 9500- 10100 9729

2352 2600 (0000) 177 7241 500- 900 613

-------------------------------------------------------------------------------

10162012Page 110 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

10162012Page 111 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

1 BFB

RELATIVE me ION ABUNDANCE CRITERIA ABUNDANCE

+-----+------------------------------------------+---------------------+| | | || 95 | Base Peak 100 relative abundance | 10000 || 50 | 1500 - 4000 of mass 95 | 2180 || 75 | 3000 - 6000 of mass 95 | 5178 || 96 | 500 - 900 of mass 95 | 653 || 173 | Less than 200 of mass 174 | 066 ( 074) || 174 | 5000 - 10000 of mass 95 | 8960 || 175 | 500 - 900 of mass 174 | 716 ( 799) || 176 | 9500 - 10100 of mass 174 | 8718 ( 9729) || 177 | 500 - 900 of mass 176 | 534 ( 613) |+-----+------------------------------------------+---------------------+

10162012Page 112 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

Data File chemVOAMS5i8260DE09-17-1211oct12be08975dSpectrum Avg Scans 50-52 ( 235) Background Scan 46

Location of Maximum 9500Number of points 149

mz Y mz Y mz Y mz Y+------------------+------------------+------------------+------------------+| 3600 1294 | 7800 45 | 13100 382 | 18200 69 || 3700 8431 | 7900 4274 | 13200 84 | 18300 115 || 3800 6991 | 8000 1313 | 13400 26 | 18600 116 || 3900 2548 | 8100 3602 | 13500 465 | 18700 340 || 4000 550 | 8200 868 | 13600 63 | 18800 34 |+------------------+------------------+------------------+------------------+| 4100 253 | 8300 128 | 13700 225 | 18900 18 || 4200 100 | 8400 171 | 13900 69 | 19900 265 || 4400 553 | 8500 53 | 14000 115 | 20100 29 || 4500 1283 | 8700 5211 | 14100 1442 | 20400 84 || 4700 1587 | 8800 4550 | 14200 269 | 20500 33 |+------------------+------------------+------------------+------------------+| 4800 651 | 9100 642 | 14300 1465 | 20600 138 || 4900 5880 | 9200 3657 | 14400 23 | 20700 20 || 5000 29536 | 9300 6715 | 14500 103 | 20900 79 || 5100 8612 | 9400 15687 | 14700 151 | 21000 74 || 5200 396 | 9500 135488 | 14800 365 | 21100 1 |+------------------+------------------+------------------+------------------+| 5300 107 | 9600 8846 | 14900 429 | 21200 140 || 5500 726 | 9700 271 | 15100 54 | 21300 52 || 5600 1691 | 9800 1 | 15300 430 | 21400 189 || 5700 4463 | 10000 110 | 15400 385 | 22100 72 || 5800 245 | 10300 207 | 15500 1021 | 22200 35 |+------------------+------------------+------------------+------------------+| 5900 116 | 10400 668 | 15600 236 | 22400 188 || 6000 1281 | 10600 562 | 15700 473 | 22600 79 || 6100 6975 | 10700 159 | 15800 3 | 22800 39 || 6200 7260 | 11000 145 | 15900 410 | 23000 95 || 6300 5465 | 11100 68 | 16100 441 | 23300 189 |+------------------+------------------+------------------+------------------+| 6400 672 | 11200 80 | 16400 208 | 23400 42 || 6500 144 | 11300 261 | 16500 57 | 23500 36 || 6600 201 | 11600 813 | 17000 641 | 23600 58 || 6700 729 | 11700 882 | 17100 38 | 24100 103 || 6800 14333 | 11800 446 | 17200 338 | 24700 36 |+------------------+------------------+------------------+------------------+| 6900 14506 | 11900 1049 | 17300 896 | 25100 40 || 7000 1361 | 12000 38 | 17400 121432 | 25500 61 || 7200 782 | 12100 249 | 17500 9704 | 25600 33 || 7300 6586 | 12400 108 | 17600 118144 | 26000 59 || 7400 24016 | 12600 138 | 17700 7241 | 26500 78 |+------------------+------------------+------------------+------------------+| 7500 70176 | 12700 39 | 17900 19 | || 7600 5444 | 12900 479 | 18000 29 | || 7700 507 | 13000 702 | 18100 322 | |+------------------+------------------+------------------+------------------+

10162012Page 113 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014U1634-04-4 Methyl tert-butyl ether 014

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 114 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

99 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

95 70-130460-00-4 4-Bromofluorobenzene

96 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 115 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 116 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08981d Report Date 12-Oct-2012 0041

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08981dLab Smp Id MB Inj Date 11-OCT-2012 2247 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info MBMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 6 QC Sample BLANKDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 381607 495518 50

52 Fluorobenzene 96 3595 3601 (1000) 1238441 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1209056 482553 48

78 Chlorobenzene-d5 117 6954 6954 (1000) 1084553 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 494380 477044 48

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 638826 500000

10162012Page 117 of 323

Data File e08981d

Date 11-OCT-2012 2247

Client ID Instrument VOAMS5i

Sample Info MB Operator GCMS VOAMS5

10162012Page 118 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1316563

Matrix e08977dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2113

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 006071-55-6 111-Trichloroethane 210

10 02275-71-8 Dichlorodifluoromethane 181

10 01074-87-3 Chloromethane 210

10 01475-01-4 Vinyl chloride 203

10 01874-83-9 Bromomethane 211

10 04096-12-8 12-Dibromo-3-Chloropropane 222

10 02195-50-1 12-Dichlorobenzene 209

10 01575-69-4 Trichlorofluoromethane 190

10 009075-35-4 11-Dichloroethene 223

10 009078-87-5 12-Dichloropropane 211

10 008076-13-1 112-Trichloro-122-trifluoroethane

203

50 2767-64-1 Acetone 250

10 01375-15-0 Carbon disulfide 218

20 03479-20-9 Methyl acetate 220

10 01875-09-2 Methylene Chloride 200

10 013156-60-5 trans-12-Dichloroethene 216

10 020124-48-1 Chlorodibromomethane 217

10 0141634-04-4 Methyl tert-butyl ether 207

10 01775-00-3 Chloroethane 201

10 01375-34-3 11-Dichloroethane 204

10 018156-59-2 cis-12-Dichloroethene 211

50 2378-93-3 2-Butanone (MEK) 214

10 008067-66-3 Chloroform 205

10 010100-41-4 Ethylbenzene 206

10 016110-82-7 Cyclohexane 208

10 006056-23-5 Carbon tetrachloride 211

10 008071-43-2 Benzene 212

10 019107-06-2 12-Dichloroethane 204

10 009079-01-6 Trichloroethene 212

10 014108-87-2 Methylcyclohexane 215

10 01275-27-4 Dichlorobromomethane 214

10 01810061-01-5 cis-13-Dichloropropene 216

50 099108-10-1 4-Methyl-2-pentanone (MIBK) 214

10 015108-88-3 Toluene 205

10 02410061-02-6 trans-13-Dichloropropene 215

FORM I 8260B

10162012Page 119 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1316563

Matrix e08977dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2113

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 01979-00-5 112-Trichloroethane 217

10 010127-18-4 Tetrachloroethene 210

50 050591-78-6 2-Hexanone 201

10 028106-93-4 12-Dibromoethane 215

10 011108-90-7 Chlorobenzene 206

30 0361330-20-7 Xylenes Total 612

10 012100-42-5 Styrene 207

10 01975-25-2 Bromoform 217

10 008098-82-8 Isopropylbenzene 207

10 01679-34-5 1122-Tetrachloroethane 210

10 014541-73-1 13-Dichlorobenzene 204

10 023106-46-7 14-Dichlorobenzene 204

10 034120-82-1 124-Trichlorobenzene 220

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

97 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 120 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08977d Report Date 11-Oct-2012 2301

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08977dLab Smp Id LCS Inj Date 11-OCT-2012 2113 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info LCSMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 2 QC Sample BSDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 92905 180886 18

3 Chloromethane 50 1016 1016 (0283) 178821 210339 21

4 Vinyl Chloride 62 1022 1028 (0284) 146748 202753 20

6 Bromomethane 94 1181 1181 (0328) 88580 210689 21

5 Chloroethane 64 1236 1242 (0344) 67759 201399 20

7 Trichlorofluoromethane 101 1297 1303 (0361) 148657 190423 19

14 Freon TF 101 1565 1577 (0435) 106548 203057 20

15 11-Dichloroethene 96 1547 1553 (0430) 94737 223085 22

16 Acetone 58 1900 1894 (0529) 14083 249674 25

18 Carbon Disulfide 76 1565 1571 (0435) 377236 218062 22

27 Methyl Acetate 74 1961 1967 (0546) 21873 219755 22

22 Methylene Chloride 49 1858 1864 (0517) 180593 200499 20

28 MTBE 73 2022 2022 (0562) 363998 207251 21

25 trans-12-Dichloroethene 96 1943 1949 (0540) 119022 216004 22

30 11-Dichloroethane 63 2303 2309 (0640) 238759 204130 20

36 cis-12-Dichloroethene 96 2650 2656 (0737) 126688 211021 21

10162012Page 121 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08977d Report Date 11-Oct-2012 2301

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 20020 214276 21

42 Chloroform 83 2845 2845 (0791) 215227 205163 20

44 Cyclohexane 56 2778 2784 (0773) 186275 208395 21

43 111-Trichloroethane 97 2979 2985 (0829) 195599 210453 21

45 Carbon Tetrachloride 117 2931 2937 (0815) 156464 210644 21

48 Benzene 78 3260 3260 (0469) 500200 211727 21

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 391700 477589 48

49 12-Dichloroethane 62 3412 3418 (0949) 178793 204379 20

52 Fluorobenzene 96 3595 3601 (1000) 1318918 500000

54 Trichloroethene 95 3735 3741 (1039) 127803 211922 21

56 Methyl cyclohexane 83 3723 3729 (1036) 159134 214991 21

57 12-Dichloropropane 63 4192 4199 (1166) 134808 211159 21

68 Bromodichloromethane 83 4272 4272 (1188) 171399 214054 21

67 cis-13-Dichloropropene 75 4906 4912 (0705) 217526 216258 22

70 4-Methyl-2-Pentanone 43 5631 5625 (0810) 134218 214248 21

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1312817 495616 50

66 Toluene 91 5162 5162 (0742) 572353 205343 20

64 trans-13-Dichloropropene 75 5650 5649 (0812) 195539 215018 22

69 112-Trichloroethane 83 5820 5820 (0837) 92220 217218 22

71 Tetrachloroethene 166 5582 5582 (0803) 145712 209847 21

73 2-Hexanone 43 6680 6680 (0961) 96649 200980 20

74 Dibromochloromethane 129 6015 6021 (0865) 132048 217333 22

77 12-Dibromoethane 107 6259 6265 (0900) 113742 214758 21

78 Chlorobenzene-d5 117 6954 6954 (1000) 1146590 500000

79 Chlorobenzene 112 6972 6972 (1003) 392243 206030 21

81 Ethylbenzene 106 7064 7064 (1016) 206211 205716 20

82 m+p-Xylene 106 7277 7277 (1046) 519872 407882 41

84 o-Xylene 106 7856 7862 (1130) 254939 203845 20

85 Styrene 104 7942 7942 (1142) 437977 207191 21

86 Bromoform 173 7911 7911 (1138) 93696 217219 22

88 Isopropylbenzene 105 8344 8350 (1200) 637526 207206 21

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 538047 484974 48

92 1122-Tetrachloroethane 83 9112 9112 (0871) 147339 210261 21

105 13-Dichlorobenzene 146 10325 10331 (0987) 330263 203584 20

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 683882 500000

109 14-Dichlorobenzene 146 10484 10490 (1002) 343961 204369 20

111 12-Dichlorobenzene 146 11148 11148 (1065) 320073 208797 21

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 26198 222454 22

114 124-Trichlorobenzene 180 12977 12977 (1240) 189475 219787 22

M 120 12-Dichloroethene (Total) 100 245711 427025 43

M 121 Xylene (Total) 100 774811 611727 61

10162012Page 122 of 323

Data File e08977d

Date 11-OCT-2012 2113

Client ID Instrument VOAMS5i

Sample Info LCS Operator GCMS VOAMS5

10162012Page 123 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MS

Matrix e08985dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0027

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 03071-55-6 111-Trichloroethane 103

50 1175-71-8 Dichlorodifluoromethane 865

50 05074-87-3 Chloromethane 102

50 07075-01-4 Vinyl chloride 104

50 09074-83-9 Bromomethane 107

50 2096-12-8 12-Dibromo-3-Chloropropane 121

50 1195-50-1 12-Dichlorobenzene 107

50 07575-69-4 Trichlorofluoromethane 121

50 04575-35-4 11-Dichloroethene 108

50 04578-87-5 12-Dichloropropane 111

50 04076-13-1 112-Trichloro-122-trifluoroethane

102

25 1367-64-1 Acetone 986

50 06575-15-0 Carbon disulfide 113

10 1779-20-9 Methyl acetate 100

50 09075-09-2 Methylene Chloride 106

50 065156-60-5 trans-12-Dichloroethene 106

50 10124-48-1 Chlorodibromomethane 116

50 0701634-04-4 Methyl tert-butyl ether 114

50 08575-00-3 Chloroethane 116

50 06575-34-3 11-Dichloroethane 104

50 090156-59-2 cis-12-Dichloroethene 105

25 1278-93-3 2-Butanone (MEK) 111

50 04067-66-3 Chloroform 108

50 050100-41-4 Ethylbenzene 107

50 080110-82-7 Cyclohexane 108

50 03056-23-5 Carbon tetrachloride 105

50 04071-43-2 Benzene 106

50 095107-06-2 12-Dichloroethane 107

50 04579-01-6 Trichloroethene 107

50 070108-87-2 Methylcyclohexane 115

50 06075-27-4 Dichlorobromomethane 113

50 09010061-01-5 cis-13-Dichloropropene 109

25 50108-10-1 4-Methyl-2-pentanone (MIBK) 111

50 075108-88-3 Toluene 106

50 1210061-02-6 trans-13-Dichloropropene 113

FORM I 8260B

10162012Page 124 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MS

Matrix e08985dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0027

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 09579-00-5 112-Trichloroethane 112

50 050127-18-4 Tetrachloroethene 110

25 25591-78-6 2-Hexanone 109

50 14106-93-4 12-Dibromoethane 116

50 055108-90-7 Chlorobenzene 107

15 181330-20-7 Xylenes Total 318

50 060100-42-5 Styrene 107

50 09575-25-2 Bromoform 115

50 04098-82-8 Isopropylbenzene 107

50 08079-34-5 1122-Tetrachloroethane 115

50 070541-73-1 13-Dichlorobenzene 106

50 12106-46-7 14-Dichlorobenzene 106

50 17120-82-1 124-Trichlorobenzene 110

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 125 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08985d Report Date 12-Oct-2012 0117

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08985dLab Smp Id 460-45537-C-2 MS Inj Date 12-OCT-2012 0027 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-C-2 MS5Misc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 10 QC Sample MSDil Factor 500000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 500000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 83204 173010 86

3 Chloromethane 50 1016 1016 (0283) 161645 203059 100

4 Vinyl Chloride 62 1022 1028 (0284) 141501 208792 100

6 Bromomethane 94 1181 1181 (0328) 84568 214819 110

5 Chloroethane 64 1236 1242 (0344) 73104 232055 120

7 Trichlorofluoromethane 101 1297 1303 (0361) 177163 242363 120

14 Freon TF 101 1571 1577 (0437) 100496 204542 100

15 11-Dichloroethene 96 1553 1553 (0432) 86070 216451 110

16 Acetone 58 1894 1894 (0527) 10416 197218 99

18 Carbon Disulfide 76 1565 1571 (0435) 366514 226264 110

27 Methyl Acetate 74 1961 1967 (0546) 18655 200164 100

22 Methylene Chloride 49 1857 1864 (0517) 178536 211689 100

28 MTBE 73 2016 2022 (0561) 376182 228747 110

25 trans-12-Dichloroethene 96 1949 1949 (0542) 109215 211677 100

30 11-Dichloroethane 63 2309 2309 (0642) 226749 207039 100

36 cis-12-Dichloroethene 96 2650 2656 (0737) 118569 210921 100

10162012Page 126 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08985d Report Date 12-Oct-2012 0117

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 19396 221710 110

42 Chloroform 83 2845 2845 (0791) 213034 216876 110

44 Cyclohexane 56 2784 2784 (0774) 180984 216238 110

43 111-Trichloroethane 97 2979 2985 (0829) 179996 206829 100

45 Carbon Tetrachloride 117 2930 2937 (0815) 145570 209299 100

48 Benzene 78 3260 3260 (0469) 482493 212344 110

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 369860 481613 48

49 12-Dichloroethane 62 3418 3418 (0951) 175178 213858 110

52 Fluorobenzene 96 3595 3601 (1000) 1234975 500000

54 Trichloroethene 95 3741 3741 (1041) 121196 214627 110

56 Methyl cyclohexane 83 3729 3729 (1037) 158792 229110 110

57 12-Dichloropropane 63 4192 4199 (1166) 132380 221450 110

68 Bromodichloromethane 83 4272 4272 (1188) 168703 225007 110

67 cis-13-Dichloropropene 75 4906 4912 (0705) 211819 218949 110

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 133223 221106 110

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1260222 494657 49

66 Toluene 91 5162 5162 (0742) 566751 211409 100

64 trans-13-Dichloropropene 75 5649 5649 (0812) 197737 226072 110

69 112-Trichloroethane 83 5820 5820 (0837) 91872 224994 110

71 Tetrachloroethene 166 5582 5582 (0803) 147320 220590 110

73 2-Hexanone 43 6674 6680 (0960) 100809 217957 110

74 Dibromochloromethane 129 6015 6021 (0865) 135240 231427 120

77 12-Dibromoethane 107 6259 6265 (0900) 117784 231222 120

78 Chlorobenzene-d5 117 6954 6954 (1000) 1102789 500000

79 Chlorobenzene 112 6972 6972 (1003) 391979 214069 110

81 Ethylbenzene 106 7064 7064 (1016) 207079 214786 110

82 m+p-Xylene 106 7277 7277 (1046) 521861 425705 210

84 o-Xylene 106 7856 7862 (1130) 254032 211187 100

85 Styrene 104 7942 7942 (1142) 433507 213222 110

86 Bromoform 173 7911 7911 (1138) 95433 230033 120

88 Isopropylbenzene 105 8350 8350 (1201) 635772 214844 110

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 518047 497030 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 151817 230609 120

105 13-Dichlorobenzene 146 10325 10331 (0987) 322106 211348 100

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 642491 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 334190 211356 100

111 12-Dichlorobenzene 146 11148 11148 (1065) 308704 214355 110

112 12-Dibromo-3-chloropropane 75 12233 12234 (1169) 26873 242889 120(R)

114 124-Trichlorobenzene 180 12977 12977 (1240) 177853 219597 110

M 120 12-Dichloroethene (Total) 100 227784 422599 210

M 121 Xylene (Total) 100 775893 636892 320

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 127 of 323

Data File e08985d

Date 12-OCT-2012 0027

Client ID Instrument VOAMS5i

Sample Info 460-45537-C-2 MS5 Operator GCMS VOAMS5

10162012Page 128 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MSD

Matrix e08986dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0051

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 03071-55-6 111-Trichloroethane 106

50 1175-71-8 Dichlorodifluoromethane 896

50 05074-87-3 Chloromethane 101

50 07075-01-4 Vinyl chloride 105

50 09074-83-9 Bromomethane 105

50 2096-12-8 12-Dibromo-3-Chloropropane 121

50 1195-50-1 12-Dichlorobenzene 111

50 07575-69-4 Trichlorofluoromethane 997

50 04575-35-4 11-Dichloroethene 119

50 04578-87-5 12-Dichloropropane 110

50 04076-13-1 112-Trichloro-122-trifluoroethane

111

25 1367-64-1 Acetone 101

50 06575-15-0 Carbon disulfide 119

10 1779-20-9 Methyl acetate 101

50 09075-09-2 Methylene Chloride 106

50 065156-60-5 trans-12-Dichloroethene 108

50 10124-48-1 Chlorodibromomethane 118

50 0701634-04-4 Methyl tert-butyl ether 116

50 08575-00-3 Chloroethane 105

50 06575-34-3 11-Dichloroethane 111

50 090156-59-2 cis-12-Dichloroethene 109

25 1278-93-3 2-Butanone (MEK) 114

50 04067-66-3 Chloroform 113

50 050100-41-4 Ethylbenzene 111

50 080110-82-7 Cyclohexane 117

50 03056-23-5 Carbon tetrachloride 110

50 04071-43-2 Benzene 114

50 095107-06-2 12-Dichloroethane 109

50 04579-01-6 Trichloroethene 113

50 070108-87-2 Methylcyclohexane 121

50 06075-27-4 Dichlorobromomethane 116

50 09010061-01-5 cis-13-Dichloropropene 115

25 50108-10-1 4-Methyl-2-pentanone (MIBK) 114

50 075108-88-3 Toluene 111

50 1210061-02-6 trans-13-Dichloropropene 119

FORM I 8260B

10162012Page 129 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MSD

Matrix e08986dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0051

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 09579-00-5 112-Trichloroethane 116

50 050127-18-4 Tetrachloroethene 116

25 25591-78-6 2-Hexanone 111

50 14106-93-4 12-Dibromoethane 117

50 055108-90-7 Chlorobenzene 111

15 181330-20-7 Xylenes Total 329

50 060100-42-5 Styrene 110

50 09575-25-2 Bromoform 114

50 04098-82-8 Isopropylbenzene 111

50 08079-34-5 1122-Tetrachloroethane 116

50 070541-73-1 13-Dichlorobenzene 110

50 12106-46-7 14-Dichlorobenzene 110

50 17120-82-1 124-Trichlorobenzene 119

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

97 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 130 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08986d Report Date 12-Oct-2012 0118

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08986dLab Smp Id 460-45537-C-2 MSD Inj Date 12-OCT-2012 0051 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-C-2 MSD5Misc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 11 QC Sample MSDDil Factor 500000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 500000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 90471 179208 90

3 Chloromethane 50 1016 1016 (0283) 169425 202751 100

4 Vinyl Chloride 62 1022 1028 (0284) 149176 209689 100

6 Bromomethane 94 1181 1181 (0328) 86595 209548 100

5 Chloroethane 64 1236 1242 (0344) 69668 210673 100

7 Trichlorofluoromethane 101 1297 1303 (0361) 152935 199307 100

14 Freon TF 101 1565 1577 (0435) 114134 221294 110

15 11-Dichloroethene 96 1547 1553 (0430) 98966 237094 120

16 Acetone 58 1900 1894 (0529) 11165 201386 100

18 Carbon Disulfide 76 1565 1571 (0435) 405349 238385 120

27 Methyl Acetate 74 1961 1967 (0546) 19684 201192 100

22 Methylene Chloride 49 1858 1864 (0517) 187993 212342 110

28 MTBE 73 2022 2022 (0562) 399850 231621 120(R)

25 trans-12-Dichloroethene 96 1943 1949 (0540) 117162 216323 110

30 11-Dichloroethane 63 2309 2309 (0642) 255983 222660 110

36 cis-12-Dichloroethene 96 2650 2656 (0737) 129220 218978 110

10162012Page 131 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08986d Report Date 12-Oct-2012 0118

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 20938 227991 110

42 Chloroform 83 2845 2845 (0791) 233404 226357 110

44 Cyclohexane 56 2778 2784 (0773) 204751 233046 120

43 111-Trichloroethane 97 2979 2985 (0829) 194508 212915 110

45 Carbon Tetrachloride 117 2931 2937 (0815) 161111 220670 110

48 Benzene 78 3260 3260 (0469) 525066 227601 110

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 386156 479012 48

49 12-Dichloroethane 62 3412 3418 (0949) 188223 218898 110

52 Fluorobenzene 96 3595 3601 (1000) 1296388 500000

54 Trichloroethene 95 3741 3741 (1041) 133629 225434 110

56 Methyl cyclohexane 83 3723 3729 (1036) 175741 241553 120

57 12-Dichloropropane 63 4192 4199 (1166) 138376 220515 110

68 Bromodichloromethane 83 4272 4272 (1188) 182026 231276 120

67 cis-13-Dichloropropene 75 4906 4912 (0705) 226245 230339 120

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 139423 227913 110

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1279885 494812 49

66 Toluene 91 5162 5162 (0742) 602122 221221 110

64 trans-13-Dichloropropene 75 5650 5649 (0812) 211878 238592 120(R)

69 112-Trichloroethane 83 5820 5820 (0837) 95786 231047 120

71 Tetrachloroethene 166 5582 5582 (0803) 157152 231769 120

73 2-Hexanone 43 6680 6680 (0961) 103997 221464 110

74 Dibromochloromethane 129 6015 6021 (0865) 140562 236912 120

77 12-Dibromoethane 107 6259 6265 (0900) 120913 233791 120

78 Chlorobenzene-d5 117 6954 6954 (1000) 1119645 500000

79 Chlorobenzene 112 6972 6972 (1003) 411739 221475 110

81 Ethylbenzene 106 7064 7064 (1016) 216984 221672 110

82 m+p-Xylene 106 7277 7277 (1046) 549474 441482 220

84 o-Xylene 106 7856 7862 (1130) 265488 217389 110

85 Styrene 104 7942 7942 (1142) 452927 219420 110

86 Bromoform 173 7911 7911 (1138) 96039 228008 110

88 Isopropylbenzene 105 8344 8350 (1200) 668990 222665 110

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 517679 487311 49

92 1122-Tetrachloroethane 83 9112 9112 (0871) 155509 231763 120

105 13-Dichlorobenzene 146 10325 10331 (0987) 342279 220349 110

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 654839 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 355256 220442 110

111 12-Dichlorobenzene 146 11148 11148 (1065) 324646 221173 110

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 27355 242581 120(R)

114 124-Trichlorobenzene 180 12977 12977 (1240) 196651 238228 120

M 120 12-Dichloroethene (Total) 100 246382 435302 220

M 121 Xylene (Total) 100 814963 658871 330

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 132 of 323

Data File e08986d

Date 12-OCT-2012 0051

Client ID Instrument VOAMS5i

Sample Info 460-45537-C-2 MSD5 Operator GCMS VOAMS5

10162012Page 133 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GCMS VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

VOAMS5

128076

Start Date

End Date 09172012 1616

09172012 0324

BFB 460-1280761 Rtx-VMS 018(mm)109172012 0324 e07834d

IC 460-1280762 Rtx-VMS 018(mm)109172012 0449 e07836d

IC 460-1280763 Rtx-VMS 018(mm)109172012 0536 e07838d

ICIS 460-1280764 Rtx-VMS 018(mm)109172012 0600 e07839d

IC 460-1280765 Rtx-VMS 018(mm)109172012 0623 e07840d

IC 460-1280766 Rtx-VMS 018(mm)109172012 0646 e07841d

IC 460-1280767 Rtx-VMS 018(mm)109172012 0710 e07842d

ZZZZZ Rtx-VMS 018(mm)109172012 0937

ZZZZZ Rtx-VMS 018(mm)109172012 1047

ZZZZZ Rtx-VMS 018(mm)109172012 1111

ZZZZZ Rtx-VMS 018(mm)109172012 1134

ZZZZZ Rtx-VMS 018(mm)109172012 1157

ZZZZZ Rtx-VMS 018(mm)509172012 1221

ZZZZZ Rtx-VMS 018(mm)509172012 1244

ZZZZZ Rtx-VMS 018(mm)109172012 1307

ZZZZZ Rtx-VMS 018(mm)109172012 1331

ZZZZZ Rtx-VMS 018(mm)109172012 1354

ZZZZZ Rtx-VMS 018(mm)109172012 1417

ZZZZZ Rtx-VMS 018(mm)109172012 1441

CCV 460-12807620 Rtx-VMS 018(mm)109172012 1616

8260B

10162012Page 134 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GCMS VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

VOAMS5

131656

Start Date

End Date 10122012 0114

10112012 2008

BFB 460-1316561 Rtx-VMS 018(mm)110112012 2008 e08975d

CCVIS 460-1316562 Rtx-VMS 018(mm)110112012 2050 e08976d

LCS 460-1316563 Rtx-VMS 018(mm)110112012 2113 e08977d

MB 460-1316564 Rtx-VMS 018(mm)110112012 2247 e08981d

460-45537-3 TB-17338-100512-253 Rtx-VMS 018(mm)110112012 2317 e08982d

460-45537-1 WC-17338-100512-MW14-MM-251

Rtx-VMS 018(mm)110112012 2341 e08983d

460-45537-2 WC-17338-100512-MW101-MM-252

Rtx-VMS 018(mm)110122012 0004 e08984d

460-45537-2 MS WC-17338-100512-MW101-MM-252 MS

Rtx-VMS 018(mm)510122012 0027 e08985d

460-45537-2 MSD WC-17338-100512-MW101-MM-252 MSD

Rtx-VMS 018(mm)510122012 0051 e08986d

CCV 460-13165610 Rtx-VMS 018(mm)110122012 0114 e08987d

8260B

10162012Page 135 of 323

10162012Page 136 of 323

10162012Page 137 of 323

10162012Page 138 of 323

10162012Page 139 of 323

Method 8082 -

DelawarePolychlorinated Biphenyls (PCBs)

(GC) by Method 8082 (Delaware)

10162012Page 140 of 323

FORM II

GC SEMI VOA SURROGATE RECOVERY

Lab Name Job No 460-45537-1

SDG No

Matrix Water Level Low

TestAmerica Edison

GC Column (1) ID (mm) GC Column (2) ID (mm)CLP-1 053 CLP-2 053

Lab Sample IDClient Sample ID DCB1 DCB2

460-45537-1WC-17338-100512-MW14-MM-251

82 83

460-45537-2WC-17338-100512-MW101-MM-252

52 50

MB 460-1309971-A

97 88

LCS 460-1309972-A

91 84

LCSD 460-1309973-A

108 99

QC LIMITSQC LIMITSDCB = DCB Decachlorobiphenyl 37-150

FORM II 8082

Column to be used to flag recovery values

10162012Page 141 of 323

GC SEMI VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vf479497dWater

Lab ID LCS 460-1309972-A Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

PCB-1016 500 507 71-126101

PCB-1260 500 557 73-130111

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 142 of 323

GC SEMI VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vr479497dWater

Lab ID LCS 460-1309972-A Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

PCB-1016 500 483 71-12697

PCB-1260 500 573 73-130115

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 143 of 323

GC SEMI VOA LAB CONTROL SAMPLE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vf479498dWater

Lab ID LCSD 460-1309973-A Client ID

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

LCSD LCSD

500 516 30 71-126PCB-1016 2103

500 583 30 73-130PCB-1260 5117

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 144 of 323

GC SEMI VOA LAB CONTROL SAMPLE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vr479498dWater

Lab ID LCSD 460-1309973-A Client ID

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

LCSD LCSD

500 497 30 71-126PCB-1016 399

500 595 30 73-130PCB-1260 4119

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 145 of 323

FORM IV

GC SEMI VOA METHOD BLANK SUMMARY

Lab Name

SDG No

Job No 460-45537-1TestAmerica Edison

Date Analyzed(1)

Instrument ID(1)

GC Column(1) ID

Instrument ID(2)

Date Extracted 10082012 0755

Date Analyzed(2)

GC Column(2) IDCLP-2053(mm) 053(mm)

PESTGC9

10082012 2208

Lab File ID(1) Lab File ID(2)

Matrix Water

vf479496d

Lab Sample ID MB 460-1309971-A

vr479496d

10082012 2208

PESTGC9

CLP-1

THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES

ANALYZED 2

DATEDATE

ANALYZED 1LAB SAMPLE IDCLIENT SAMPLE ID

LCS 460-1309972-A 10082012 2224 10082012 2224

LCSD 460-1309973-A 10082012 2239 10082012 2239

460-45537-1WC-17338-100512-MW14-MM-251

10092012 0029 10092012 0029

460-45537-2WC-17338-100512-MW101-MM-252

10092012 0045 10092012 0045

FORM IV 8082

10162012Page 146 of 323

GC SEMI VOA ANALYTICAL SEQUENCE

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVRT 460-1311372 Date Analyzed 10082012 1830

Lab File ID (Standard) vf479493d

Instrument ID PESTGC9 GC Column CLP-2 ID 053(mm)

Heated Purge (YN) N

Calibration ID 17840

THE ANALYTICAL SEQUENCE OF BLANKS SAMPLES STANDARDS MSMSDs AND LCSs IS GIVEN BELOW

RT

DCB

UPPER LIMIT

LOWER LIMIT

1159

1139

CONTINUING CALIBRATION SURROGATE 1149

LAB SAMPLE ID DATE ANALYZEDCLIENT SAMPLE ID LAB FILE ID

CCVRT 460-1311372 10082012 1830 1149vf479493d

MB 460-1309971-A 10082012 2208 1148vf479496d

LCS 460-1309972-A 10082012 2224 1148vf479497d

LCSD 460-1309973-A 10082012 2239 1148vf479498d

460-45537-1 10092012 0029 1149WC-17338-100512-MW14-MM-251

vf479505d

460-45537-2 10092012 0045 1149WC-17338-100512-MW101-MM-252

vf479506d

PIBLK 460-13113718 10092012 0131 1149vf479509d

CCV 460-13113719 10092012 0147 1149vf479510d

DCB = DCB Decachlorobiphenyl

DCB RT Limit = plusmn 01 minutes of surrogate RT

Column used to flag values outside QC limits

FORM VIII 8082

10162012Page 147 of 323

GC SEMI VOA ANALYTICAL SEQUENCE

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVRT 460-1311372 Date Analyzed 10082012 1830

Lab File ID (Standard) vr479493d

Instrument ID PESTGC9 GC Column CLP-1 ID 053(mm)

Heated Purge (YN) N

Calibration ID 17839

THE ANALYTICAL SEQUENCE OF BLANKS SAMPLES STANDARDS MSMSDs AND LCSs IS GIVEN BELOW

RT

DCB

UPPER LIMIT

LOWER LIMIT

1071

1051

CONTINUING CALIBRATION SURROGATE 1061

LAB SAMPLE ID DATE ANALYZEDCLIENT SAMPLE ID LAB FILE ID

CCVRT 460-1311372 10082012 1830 1061vr479493d

MB 460-1309971-A 10082012 2208 1061vr479496d

LCS 460-1309972-A 10082012 2224 1061vr479497d

LCSD 460-1309973-A 10082012 2239 1061vr479498d

460-45537-1 10092012 0029 1061WC-17338-100512-MW14-MM-251

vr479505d

460-45537-2 10092012 0045 1061WC-17338-100512-MW101-MM-252

vr479506d

PIBLK 460-13113718 10092012 0131 1061vr479509d

CCV 460-13113719 10092012 0147 1061vr479510d

DCB = DCB Decachlorobiphenyl

DCB RT Limit = plusmn 01 minutes of surrogate RT

Column used to flag values outside QC limits

FORM VIII 8082

10162012Page 148 of 323

FORM XForm 1

Client Sample ID

Lab Name Job No

SDG No

Lab Sample ID LCS 460-1309972-A

Instrument ID (1) Instrument ID (2)

Date Analyzed (1) Date Analyzed (2)

GC Column (1) ID GC Column (2) ID

TestAmerica Edison 460-45537-1

IDENTIFICATION SUMMARYForm 1

053(mm) 053(mm)

10082012 2224 10082012 2224

PESTGC9 PESTGC9

CLP-1 CLP-2

ANALYTE COL PEAK RTRT WINDOW

FROM TO PEAK MEAN

CONCENTRATIONRPD

PCB-1016 1 1 206 201 215 473 483 47

2 250 246 260 494

3 275 271 285 530

4 310 306 320 501

5 330 326 340 520

6 369 361 375 302

7 401 397 411 541

8 419 412 426 505

2 1 293 289 303 525 507

2 360 357 371 562

3 404 401 415 567

4 444 441 455 558

5 468 465 479 594

6 518 509 523 402

7 557 547 561 259

8 571 568 582 584

PCB-1260 1 1 605 600 614 554 573 28

2 650 645 659 558

3 694 689 703 581

4 714 709 723 548

5 758 753 767 565

6 886 882 896 559

7 908 904 918 619

8 1014 1008 1022 600

2 1 771 769 783 600 557

2 817 814 828 594

3 903 901 915 625

4 928 926 940 622

5 941 938 952 643

6 986 983 997 612

7 1062 1055 1069 212

8 1106 1102 1116 550

FORM X 8082

10162012Page 149 of 323

FORM XForm 1

Client Sample ID

Lab Name Job No

SDG No

Lab Sample ID LCSD 460-1309973-A

Instrument ID (1) Instrument ID (2)

Date Analyzed (1) Date Analyzed (2)

GC Column (1) ID GC Column (2) ID

TestAmerica Edison 460-45537-1

IDENTIFICATION SUMMARYForm 1

053(mm) 053(mm)

10082012 2239 10082012 2239

PESTGC9 PESTGC9

CLP-1 CLP-2

ANALYTE COL PEAK RTRT WINDOW

FROM TO PEAK MEAN

CONCENTRATIONRPD

PCB-1016 1 1 206 201 215 483 497 38

2 250 246 260 505

3 275 271 285 542

4 310 306 320 510

5 330 326 340 529

6 368 361 375 369

7 401 397 411 549

8 419 412 426 491

2 1 292 289 303 535 516

2 359 357 371 574

3 404 401 415 572

4 443 441 455 572

5 468 465 479 606

6 518 509 523 407

7 557 547 561 267

8 571 568 582 599

PCB-1260 1 1 605 600 614 565 595 19

2 650 645 659 571

3 694 689 703 595

4 714 709 723 563

5 757 753 767 585

6 886 882 896 582

7 908 904 918 656

8 1014 1008 1022 639

2 1 771 769 783 615 583

2 816 814 828 610

3 902 901 915 645

4 928 926 940 648

5 940 938 952 669

6 986 983 997 637

7 1062 1055 1069 253

8 1106 1102 1116 590

FORM X 8082

10162012Page 150 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix vf479505dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1000

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0029

5(mL)

Sample wtvol 980(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

83 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 151 of 323

Data File vf479505d Report Date 09-Oct-2012 0313

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479505dLab Smp Id 460-45537-E-1-B Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0029 Operator Inst ID PESTGC9iSmp Info 460-45537-E-1-BMisc Info 460-45537-E-1-BComment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 35 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 98000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11489 11515 -0026 22061081 829479 042 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 152 of 323

Data File vf479505d

Date 09-OCT-2012 0029

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-1-B Operator

10162012Page 153 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix vr479505dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1000

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0029

5(mL)

Sample wtvol 980(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

051 013U12674-11-2 PCB-1016 013

051 029U11104-28-2 PCB-1221 029

051 012U11141-16-5 PCB-1232 012

051 012U53469-21-9 PCB-1242 012

051 024U12672-29-6 PCB-1248 024

051 017U11097-69-1 PCB-1254 017

051 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

82 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 154 of 323

Data File vr479505d Report Date 09-Oct-2012 0303

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479505dLab Smp Id 460-45537-E-1-B Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0029 Operator Inst ID PESTGC9iSmp Info 460-45537-E-1-BMisc Info 460-45537-E-1-BComment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 35 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 98000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 38407031 815954 042 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 155 of 323

Data File vr479505d

Date 09-OCT-2012 0029

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-1-B Operator

10162012Page 156 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix vf479506dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1230

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0045

5(mL)

Sample wtvol 990(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

50 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 157 of 323

Data File vf479506d Report Date 09-Oct-2012 0322

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479506dLab Smp Id 460-45537-E-2-A Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0045 Operator Inst ID PESTGC9iSmp Info 460-45537-E-2-AMisc Info 460-45537-E-2-AComment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 36 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 99000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11487 11515 -0028 13346591 501821 025 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 158 of 323

Data File vf479506d

Date 09-OCT-2012 0045

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-2-A Operator

10162012Page 159 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix vr479506dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1230

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0045

5(mL)

Sample wtvol 990(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

051 013U12674-11-2 PCB-1016 013

051 028U11104-28-2 PCB-1221 028

051 012U11141-16-5 PCB-1232 012

051 012U53469-21-9 PCB-1242 012

051 024U12672-29-6 PCB-1248 024

051 017U11097-69-1 PCB-1254 017

051 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

52 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 160 of 323

Data File vr479506d Page 1 Report Date 09-Oct-2012 0322

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479506dLab Smp Id 460-45537-E-2-A Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0045 Operator Inst ID PESTGC9iSmp Info 460-45537-E-2-AMisc Info 460-45537-E-2-AComment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 36 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 99000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 24675227 524223 026 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 161 of 323

Data File vr479506d

Date 09-OCT-2012 0045

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-2-A Operator

10162012Page 162 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vf479200dLevel 2 IC 460-1299268 vf479201dLevel 3 IC 460-1299269 vf479202dLevel 4 IC 460-12992610 vf479203dLevel 5 IC 460-12992611 vf479204d

ANALYTE LVL 1 LVL 2 LVL 3 LVL 4 LVL 5 AVG RTRT WINDOW

PCB-1016 Peak 1 29602891 - 30312960 2960 2961 2959 2959PCB-1016 Peak 2 36403571 - 37113640 3640 3641 3639 3640PCB-1016 Peak 3 40844015 - 41554084 4084 4085 4083 4083PCB-1016 Peak 4 44774409 - 45494477 4477 4479 4477 4476PCB-1016 Peak 5 47224652 - 47924722 4722 4722 4722 4722PCB-1016 Peak 6 51575088 - 52285157 5158 5158 5157 5157PCB-1016 Peak 7 55425472 - 56125542 5543 5542 5542 5542PCB-1016 Peak 8 57515682 - 58225751 5751 5752 5751 5751PCB-1260 Peak 1 77567686 - 78267756 7756 7756 7756 7755PCB-1260 Peak 2 82158145 - 82858216 8215 8215 8215 8215PCB-1260 Peak 3 90839014 - 91549084 9084 9084 9083 9082PCB-1260 Peak 4 93329262 - 94029332 9332 9332 9332 9331PCB-1260 Peak 5 94549384 - 95249454 9454 9454 9454 9453PCB-1260 Peak 6 99019831 - 99719901 9901 9901 9901 9901PCB-1260 Peak 7 1061710546 - 1068610617 10617 10616 10617 10616PCB-1260 Peak 8 1108611016 - 1115611087 11087 11086 11084 11085DCB Decachlorobiphenyl 1151511415 - 1161511518 11520 11515 11510 11512

FORM VI 8082 10162012Page 163 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1299267 vf479200d2Level IC 460-1299268 vf479201d3Level IC 460-1299269 vf479202d4Level IC 460-12992610 vf479203d5Level IC 460-12992611 vf479204d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1016 Peak 1 Ave 155 20012858 10484 96475 9762186122

102726535

PCB-1016 Peak 2 Ave 122 20025248 21181 20808 2014318185

211130015

PCB-1016 Peak 3 Ave 124 20010359 90007 83526 8441074163

871400841

PCB-1016 Peak 4 Ave 130 20045579 38951 35291 3591632814

377100165

PCB-1016 Peak 5 Ave 129 20019485 17677 14821 1595214340

164548979

PCB-1016 Peak 6 Ave 171 20012410 10306 89543 9039281426

977025128

PCB-1016 Peak 7 Ave 161 20015097 12427 11165 1121510046

119900052

PCB-1016 Peak 8 Ave 121 20014456 12522 11609 1161310532

121463746

PCB-1260 Peak 1 Ave 165 20028165 22320 20852 2059718598

221063931

PCB-1260 Peak 2 Ave 173 20032398 25230 23518 2315121164

250922627

PCB-1260 Peak 3 Ave 101 20042792 37584 35706 3549332757

368665853

PCB-1260 Peak 4 Ave 114 20019125 16727 15681 1547514194

162405856

PCB-1260 Peak 5 Ave 71 20097407 90339 86445 8609680436

881445133

PCB-1260 Peak 6 Ave 116 20020218 16837 16387 1620514980

169255417

PCB-1260 Peak 7 Ave 115 20025044 20516 20530 2080218426

210635761

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 164 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1260 Peak 8 Ave 114 20092729 80982 75320 7482969000

785718832

DCB Decachlorobiphenyl Ave 104 200306013 281530 257456 246481238335

265963086

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 165 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vf479200dLevel 2 IC 460-1299268 vf479201dLevel 3 IC 460-1299269 vf479202dLevel 4 IC 460-12992610 vf479203dLevel 5 IC 460-12992611 vf479204d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1LVL 2 LVL 2LVL 3 LVL 3LVL 4 LVL 4LVL 5 LVL 5

PCB-1016 Peak 1 Ave 1285777 5241842 9647477 14643185 21530533 100 500 1000 1500 2500PCB-1016 Peak 2 Ave 2524804 10590544 20808307 30213965 45462323 100 500 1000 1500 2500PCB-1016 Peak 3 Ave 1035943 4500373 8352607 12661468 18540701 100 500 1000 1500 2500PCB-1016 Peak 4 Ave 4557926 19475271 35290615 53874092 82034010 100 500 1000 1500 2500PCB-1016 Peak 5 Ave 1948484 8838480 14821328 23927783 35848765 100 500 1000 1500 2500PCB-1016 Peak 6 Ave 1240957 5152808 8954270 13558761 20356566 100 500 1000 1500 2500PCB-1016 Peak 7 Ave 1509707 6213265 11165134 16822458 25115800 100 500 1000 1500 2500PCB-1016 Peak 8 Ave 1445572 6260864 11609452 17418946 26330856 100 500 1000 1500 2500PCB-1260 Peak 1 Ave 2816529 11159859 20851674 30895442 46495806 100 500 1000 1500 2500PCB-1260 Peak 2 Ave 3239811 12615093 23518487 34726449 52908911 100 500 1000 1500 2500PCB-1260 Peak 3 Ave 4279245 18792136 35705636 53240044 81893015 100 500 1000 1500 2500PCB-1260 Peak 4 Ave 1912505 8363664 15681452 23213228 35484032 100 500 1000 1500 2500PCB-1260 Peak 5 Ave 974074 4516956 8644462 12914338 20108960 100 500 1000 1500 2500PCB-1260 Peak 6 Ave 2021814 8418625 16386843 24307809 37450674 100 500 1000 1500 2500PCB-1260 Peak 7 Ave 2504445 10257895 20530020 31202581 46064749 100 500 1000 1500 2500PCB-1260 Peak 8 Ave 927285 4049088 7531982 11224374 17250044 100 500 1000 1500 2500DCB Decachlorobiphenyl Ave 7650320 14076513 25745578 36972164 47667099 250 500 100 150 200

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 166 of 323

Data File vf479200d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479200dLab Smp Id IC-SG1660L1_00013 Inj Date 30-SEP-2012 1704 Operator Inst ID PESTGC9iSmp Info ic-SG1660L1_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1704 Cal File vf479200dAls bottle 7 Calibration Sample Level 1Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2960 2961 -0001 1285777 100000 120 8000- 12000 10000

3640 3641 -0001 2524804 100000 120 15709- 23564 19636

4084 4085 -0001 1035943 100000 120 6446- 9668 8057

4477 4479 -0002 4557926 100000 120 28359- 42539 35449

4722 4722 0000 1948484 100000 120 12123- 18185 15154

5157 5158 -0001 1240957 100000 130 7721- 11582 9651

5542 5542 0000 1509707 100000 120 9393- 14090 11742

5751 5752 -0001 1445572 100000 120 8994- 13491 11243

Average of Peak Amounts = 122

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 2816529 100000 130 8000- 12000 10000(M)

10162012Page 167 of 323

Data File vf479200d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8216 8215 0001 3239811 100000 130 9202- 13803 11503

9084 9084 0000 4279245 100000 120 12155- 18232 15193

9332 9332 0000 1912505 100000 120 5432- 8148 6790

9454 9454 0000 974074 100000 110 2767- 4150 3458

9901 9901 0000 2021814 100000 120 5743- 8614 7178

10617 10616 0001 2504445 100000 120 7114- 10670 8892

11087 11086 0001 927285 100000 120 2634- 3951 3292

Average of Peak Amounts = 120

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11518 11515 0003 7650320 250000 29 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 168 of 323

Data File vf479200d

Date 30-SEP-2012 1704

Client ID Instrument PESTGC9i

Sample Info ic-SG1660L1_00013 Operator

10162012Page 169 of 323

Data File vf479201d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479201dLab Smp Id IC-SG1660L2_00013 Inj Date 30-SEP-2012 1720 Operator Inst ID PESTGC9iSmp Info SG1660L2_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1720 Cal File vf479201dAls bottle 8 Calibration Sample Level 2Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2960 2961 -0001 5241842 500000 510 8000- 12000 10000

3640 3641 -0001 10590544 500000 500 16163- 24245 20204

4084 4085 -0001 4500373 500000 520 6868- 10303 8585

4477 4479 -0002 19475271 500000 520 29723- 44584 37153

4722 4722 0000 8838480 500000 540 13489- 20234 16861

5158 5158 0000 5152808 500000 530 7864- 11796 9830

5543 5542 0001 6213265 500000 520 9483- 14224 11853

5751 5752 -0001 6260864 500000 520 9555- 14333 11944

Average of Peak Amounts = 518

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 11159859 500000 500 8000- 12000 10000(M)

10162012Page 170 of 323

Data File vf479201d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 12615093 500000 500 9043- 13565 11304

9084 9084 0000 18792136 500000 510 13471- 20207 16839

9332 9332 0000 8363664 500000 510 5996- 8993 7494

9454 9454 0000 4516956 500000 510 3238- 4857 4048

9901 9901 0000 8418625 500000 500 6035- 9052 7544

10617 10616 0001 10257895 500000 490 7353- 11030 9192

11087 11086 0001 4049088 500000 520 2903- 4354 3628

Average of Peak Amounts = 506

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11520 11515 0005 14076513 500000 53 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 171 of 323

Data File vf479201d

Date 30-SEP-2012 1720

Client ID Instrument PESTGC9i

Sample Info SG1660L2_00013 Operator

10162012Page 172 of 323

Data File vf479202d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479202dLab Smp Id IC-SG1660L3_00019 Inj Date 30-SEP-2012 1735 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 9 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2961 2961 0000 9647477 100000 940 8000- 12000 10000

3641 3641 0000 20808307 100000 980 17255- 25882 21569

4085 4085 0000 8352607 100000 960 6926- 10389 8658

4479 4479 0000 35290615 100000 940 29264- 43896 36580

4722 4722 0000 14821328 100000 900 12290- 18435 15363

5158 5158 0000 8954270 100000 920 7425- 11138 9281

5542 5542 0000 11165134 100000 930 9258- 13888 11573

5752 5752 0000 11609452 100000 960 9627- 14440 12034

Average of Peak Amounts = 940

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 20851674 100000 940 8000- 12000 10000(M)

10162012Page 173 of 323

Data File vf479202d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 23518487 100000 940 9023- 13535 11279

9084 9084 0000 35705636 100000 970 13699- 20548 17124

9332 9332 0000 15681452 100000 960 6016- 9025 7520

9454 9454 0000 8644462 100000 980 3317- 4975 4146

9901 9901 0000 16386843 100000 970 6287- 9431 7859

10616 10616 0000 20530020 100000 970 7877- 11815 9846

11086 11086 0000 7531982 100000 960 2890- 4335 3612

Average of Peak Amounts = 962

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11515 11515 0000 25745578 100000 97 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 174 of 323

Data File vf479202d

Date 30-SEP-2012 1735

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 175 of 323

Data File vf479203d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479203dLab Smp Id IC-SG1660L4_00013 Inj Date 30-SEP-2012 1751 Operator Inst ID PESTGC9iSmp Info SG1660L4_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1751 Cal File vf479203dAls bottle 10 Calibration Sample Level 4Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2959 2961 -0002 14643185 150000 1400 8000- 12000 10000

3639 3641 -0002 30213965 150000 1400 16507- 24760 20633

4083 4085 -0002 12661468 150000 1400 6917- 10376 8647

4477 4479 -0002 53874092 150000 1400 29433- 44149 36791

4722 4722 0000 23927783 150000 1400 13072- 19609 16341

5157 5158 -0001 13558761 150000 1400 7408- 11111 9259

5542 5542 0000 16822458 150000 1400 9191- 13786 11488

5751 5752 -0001 17418946 150000 1400 9516- 14275 11896

Average of Peak Amounts = 143e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 30895442 150000 1400 8000- 12000 10000(M)

10162012Page 176 of 323

Data File vf479203d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 34726449 150000 1400 8992- 13488 11240

9083 9084 -0001 53240044 150000 1400 13786- 20679 17232

9332 9332 0000 23213228 150000 1400 6011- 9016 7513

9454 9454 0000 12914338 150000 1500 3344- 5016 4180

9901 9901 0000 24307809 150000 1400 6294- 9441 7868

10617 10616 0001 31202581 150000 1500 8080- 12119 10099

11084 11086 -0002 11224374 150000 1400 2906- 4360 3633

Average of Peak Amounts = 143e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11510 11515 -0005 36972164 150000 140 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 177 of 323

Data File vf479203d

Date 30-SEP-2012 1751

Client ID Instrument PESTGC9i

Sample Info SG1660L4_00013 Operator

10162012Page 178 of 323

Data File vf479204d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479204dLab Smp Id IC-SG1660L5_00013 Inj Date 30-SEP-2012 1807 Operator Inst ID PESTGC9iSmp Info SG1660L5_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1807 Cal File vf479204dAls bottle 11 Calibration Sample Level 5Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2959 2961 -0002 21530533 250000 2100 8000- 12000 10000

3640 3641 -0001 45462323 250000 2200 16892- 25338 21115

4083 4085 -0002 18540701 250000 2100 6889- 10334 8611

4476 4479 -0003 82034010 250000 2200 30481- 45721 38101

4722 4722 0000 35848765 250000 2200 13320- 19980 16650

5157 5158 -0001 20356566 250000 2100 7564- 11346 9455

5542 5542 0000 25115800 250000 2100 9332- 13998 11665

5751 5752 -0001 26330856 250000 2200 9784- 14675 12230

Average of Peak Amounts = 213e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7755 7756 -0001 46495806 250000 2100 8000- 12000 10000(M)

10162012Page 179 of 323

Data File vf479204d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 52908911 250000 2100 9103- 13655 11379

9082 9084 -0002 81893015 250000 2200 14090- 21136 17613

9331 9332 -0001 35484032 250000 2200 6105- 9158 7632

9453 9454 -0001 20108960 250000 2300 3460- 5190 4325

9901 9901 0000 37450674 250000 2200 6444- 9666 8055

10616 10616 0000 46064749 250000 2200 7926- 11889 9907

11085 11086 -0001 17250044 250000 2200 2968- 4452 3710

Average of Peak Amounts = 219e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11512 11515 -0003 47667099 200000 180 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 180 of 323

Data File vf479204d

Date 30-SEP-2012 1807

Client ID Instrument PESTGC9i

Sample Info SG1660L5_00013 Operator

10162012Page 181 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vr479200dLevel 2 IC 460-1299268 vr479201dLevel 3 IC 460-1299269 vr479202dLevel 4 IC 460-12992610 vr479203dLevel 5 IC 460-12992611 vr479204d

ANALYTE LVL 1 LVL 2 LVL 3 LVL 4 LVL 5 AVG RTRT WINDOW

PCB-1016 Peak 1 20842015 - 21552085 2084 2085 2083 2084PCB-1016 Peak 2 25272457 - 25972527 2526 2527 2527 2526PCB-1016 Peak 3 27762707 - 28472777 2776 2777 2775 2775PCB-1016 Peak 4 31283060 - 32003128 3128 3130 3128 3127PCB-1016 Peak 5 33293260 - 34003329 3329 3330 3328 3328PCB-1016 Peak 6 36823615 - 37553682 3682 3685 3683 3681PCB-1016 Peak 7 40433973 - 41134042 4043 4043 4042 4043PCB-1016 Peak 8 41904121 - 42614190 4190 4191 4188 4190PCB-1260 Peak 1 60716002 - 61426072 6072 6072 6071 6071PCB-1260 Peak 2 65226452 - 65926522 6523 6522 6522 6521PCB-1260 Peak 3 69646894 - 70346964 6965 6964 6963 6964PCB-1260 Peak 4 71647095 - 72357165 7165 7165 7164 7164PCB-1260 Peak 5 76027532 - 76727602 7603 7602 7602 7601PCB-1260 Peak 6 88938823 - 89638893 8894 8893 8893 8892PCB-1260 Peak 7 91159045 - 91859115 9115 9115 9115 9114PCB-1260 Peak 8 1015310083 - 1022310153 10154 10153 10153 10153DCB Decachlorobiphenyl 1062410524 - 1072410625 10625 10624 10624 10624

FORM VI 8082 10162012Page 182 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1299267 vr479200d2Level IC 460-1299268 vr479201d3Level IC 460-1299269 vr479202d4Level IC 460-12992610 vr479203d5Level IC 460-12992611 vr479204d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1016 Peak 1 Ave 197 20021391 15827 14690 1421213626

159493236

PCB-1016 Peak 2 Ave 165 20034434 28377 25503 2514722693

272309984

PCB-1016 Peak 3 Ave 77 20020149 18502 16986 1713716990

179529604

PCB-1016 Peak 4 Ave 163 20075334 61344 55787 5498850020

594947119

PCB-1016 Peak 5 Ave 111 20026774 23733 21963 2197020028

228936643

PCB-1016 Peak 6 Ave 186 20030865 24479 22517 2109919526

236972316

PCB-1016 Peak 7 Ave 97 20025842 23012 21540 2153920131

224127747

PCB-1016 Peak 8 Ave 151 20012619 94689 86303 1057294995

101578271

PCB-1260 Peak 1 Ave 163 20041532 33110 31025 3015327565

326771001

PCB-1260 Peak 2 Ave 177 20078411 60909 57128 5539650491

604671657

PCB-1260 Peak 3 Ave 138 20068452 55082 53236 5187948612

554520757

PCB-1260 Peak 4 Ave 154 20037971 30462 28586 2772626073

301638112

PCB-1260 Peak 5 Ave 148 20034082 26592 25567 2477624302

270637128

PCB-1260 Peak 6 Ave 81 20038982 34673 33173 3331131697

343672090

PCB-1260 Peak 7 Ave 66 20023297 21847 20031 2012320512

211620048

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 183 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1260 Peak 8 Ave 59 20018824 17382 16914 1709216013

172450198

DCB Decachlorobiphenyl Ave 109 200544588 499440 455074 438703415700

470701073

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 184 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vr479200dLevel 2 IC 460-1299268 vr479201dLevel 3 IC 460-1299269 vr479202dLevel 4 IC 460-12992610 vr479203dLevel 5 IC 460-12992611 vr479204d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1LVL 2 LVL 2LVL 3 LVL 3LVL 4 LVL 4LVL 5 LVL 5

PCB-1016 Peak 1 Ave 2139086 7913738 14690255 21317999 34065069 100 500 1000 1500 2500PCB-1016 Peak 2 Ave 3443416 14188692 25503333 37720095 56733462 100 500 1000 1500 2500PCB-1016 Peak 3 Ave 2014938 9251204 16986172 25705034 42475382 100 500 1000 1500 2500PCB-1016 Peak 4 Ave 7533379 30672168 55786970 82482485 125050351 100 500 1000 1500 2500PCB-1016 Peak 5 Ave 2677413 11866731 21962918 32955239 50069130 100 500 1000 1500 2500PCB-1016 Peak 6 Ave 3086462 12239557 22517485 31648230 48815297 100 500 1000 1500 2500PCB-1016 Peak 7 Ave 2584175 11505820 21540272 32309208 50326849 100 500 1000 1500 2500PCB-1016 Peak 8 Ave 1261883 4734436 8630325 15857466 23748661 100 500 1000 1500 2500PCB-1260 Peak 1 Ave 4153239 16554914 31025367 45229464 68912349 100 500 1000 1500 2500PCB-1260 Peak 2 Ave 7841143 30454619 57128111 83094008 126227611 100 500 1000 1500 2500PCB-1260 Peak 3 Ave 6845178 27541094 53235986 77818190 121529078 100 500 1000 1500 2500PCB-1260 Peak 4 Ave 3797116 15230911 28586487 41589423 65183263 100 500 1000 1500 2500PCB-1260 Peak 5 Ave 3408191 13295973 25567248 37163734 60754093 100 500 1000 1500 2500PCB-1260 Peak 6 Ave 3898216 17336408 33172625 49966572 79243490 100 500 1000 1500 2500PCB-1260 Peak 7 Ave 2329661 10923449 20031237 30184937 51279969 100 500 1000 1500 2500PCB-1260 Peak 8 Ave 1882356 8691093 16914378 25637846 40032694 100 500 1000 1500 2500DCB Decachlorobiphenyl Ave 13614701 24972013 45507407 65805444 83140007 250 500 100 150 200

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 185 of 323

Data File vr479200d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479200dLab Smp Id IC-SG1660L1_00013 Inj Date 30-SEP-2012 1704 Operator Inst ID PESTGC9iSmp Info ic-SG1660L1_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 7 Calibration Sample Level 1Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2085 2085 0000 2139086 100000 130 8000- 12000 10000(M)

2527 2527 0000 3443416 100000 130 13324- 19985 16098

2777 2777 0000 2014938 100000 110 9975- 14963 9420

3128 3130 -0002 7533379 100000 130 29367- 44051 35218

3329 3330 -0001 2677413 100000 120 11758- 17638 12517

3682 3685 -0003 3086462 100000 130 11464- 17196 14429

4042 4043 -0001 2584175 100000 120 11819- 17728 12081

4190 4191 -0001 1261883 100000 120 5577- 8366 5899

Average of Peak Amounts = 123

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 4153239 100000 130 8000- 12000 10000

10162012Page 186 of 323

Data File vr479200d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 7841143 100000 130 14654- 21981 18880

6964 6964 0000 6845178 100000 120 14108- 21162 16482

7165 7165 0000 3797116 100000 120 7567- 11351 9143

7602 7602 0000 3408191 100000 120 7053- 10579 8206

8893 8893 0000 3898216 100000 110 9199- 13799 9386

9115 9115 0000 2329661 100000 110 5953- 8930 5609

10153 10153 0000 1882356 100000 110 4647- 6971 4532

Average of Peak Amounts = 121

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10625 10624 0001 13614701 250000 29 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 187 of 323

Data File vr479200d

Date 30-SEP-2012 1704

Client ID Instrument PESTGC9i

Sample Info ic-SG1660L1_00013 Operator

10162012Page 188 of 323

Data File vr479201d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479201dLab Smp Id IC-SG1660L2_00013 Inj Date 30-SEP-2012 1720 Operator Inst ID PESTGC9iSmp Info SG1660L2_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 8 Calibration Sample Level 2Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2084 2085 -0001 7913738 500000 500 8000- 12000 10000(M)

2526 2527 -0001 14188692 500000 520 13324- 19985 17929

2776 2777 -0001 9251204 500000 520 9975- 14963 11690

3128 3130 -0002 30672168 500000 520 29367- 44051 38758

3329 3330 -0001 11866731 500000 520 11758- 17638 14995

3682 3685 -0003 12239557 500000 520 11464- 17196 15466

4043 4043 0000 11505820 500000 510 11819- 17728 14539

4190 4191 -0001 4734436 500000 470 5577- 8366 5983

Average of Peak Amounts = 508

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 16554914 500000 510 8000- 12000 10000

10162012Page 189 of 323

Data File vr479201d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6523 6522 0001 30454619 500000 500 14654- 21981 18396

6965 6964 0001 27541094 500000 500 14108- 21162 16636

7165 7165 0000 15230911 500000 500 7567- 11351 9200

7603 7602 0001 13295973 500000 490 7053- 10579 8031

8894 8893 0001 17336408 500000 500 9199- 13799 10472

9115 9115 0000 10923449 500000 520 5953- 8930 6598

10154 10153 0001 8691093 500000 500 4647- 6971 5250

Average of Peak Amounts = 503

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10625 10624 0001 24972013 500000 53 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 190 of 323

Data File vr479201d

Date 30-SEP-2012 1720

Client ID Instrument PESTGC9i

Sample Info SG1660L2_00013 Operator

10162012Page 191 of 323

Data File vr479202d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479202dLab Smp Id IC-SG1660L3_00019 Inj Date 30-SEP-2012 1735 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 9 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2085 2085 0000 14690255 100000 920 8000- 12000 10000(M)

2527 2527 0000 25503333 100000 940 13324- 19985 17361

2777 2777 0000 16986172 100000 950 9975- 14963 11563

3130 3130 0000 55786970 100000 940 29367- 44051 37975

3330 3330 0000 21962918 100000 960 11758- 17638 14951

3685 3685 0000 22517485 100000 950 11464- 17196 15328

4043 4043 0000 21540272 100000 960 11819- 17728 14663

4191 4191 0000 8630325 100000 850 5577- 8366 5875

Average of Peak Amounts = 933

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 31025367 100000 950 8000- 12000 10000

10162012Page 192 of 323

Data File vr479202d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 57128111 100000 940 14654- 21981 18413

6964 6964 0000 53235986 100000 960 14108- 21162 17159

7165 7165 0000 28586487 100000 950 7567- 11351 9214

7602 7602 0000 25567248 100000 940 7053- 10579 8241

8893 8893 0000 33172625 100000 960 9199- 13799 10692

9115 9115 0000 20031237 100000 950 5953- 8930 6456

10153 10153 0000 16914378 100000 980 4647- 6971 5452

Average of Peak Amounts = 955

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 45507407 100000 97 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 193 of 323

Data File vr479202d

Date 30-SEP-2012 1735

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 194 of 323

Data File vr479203d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479203dLab Smp Id IC-SG1660L4_00013 Inj Date 30-SEP-2012 1751 Operator Inst ID PESTGC9iSmp Info SG1660L4_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 10 Calibration Sample Level 4Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2083 2085 -0002 21317999 150000 1300 8000- 12000 10000(M)

2527 2527 0000 37720095 150000 1400 13324- 19985 17694

2775 2777 -0002 25705034 150000 1400 9975- 14963 12058

3128 3130 -0002 82482485 150000 1400 29367- 44051 38691

3328 3330 -0002 32955239 150000 1400 11758- 17638 15459

3683 3685 -0002 31648230 150000 1300 11464- 17196 14846

4042 4043 -0001 32309208 150000 1400 11819- 17728 15156

4188 4191 -0003 15857466 150000 1600 5577- 8366 7439

Average of Peak Amounts = 141e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6071 6072 -0001 45229464 150000 1400 8000- 12000 10000

10162012Page 195 of 323

Data File vr479203d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 83094008 150000 1400 14654- 21981 18372

6963 6964 -0001 77818190 150000 1400 14108- 21162 17205

7164 7165 -0001 41589423 150000 1400 7567- 11351 9195

7602 7602 0000 37163734 150000 1400 7053- 10579 8217

8893 8893 0000 49966572 150000 1400 9199- 13799 11047

9115 9115 0000 30184937 150000 1400 5953- 8930 6674

10153 10153 0000 25637846 150000 1500 4647- 6971 5668

Average of Peak Amounts = 141e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 65805444 150000 140 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 196 of 323

Data File vr479203d

Date 30-SEP-2012 1751

Client ID Instrument PESTGC9i

Sample Info SG1660L4_00013 Operator

10162012Page 197 of 323

Data File vr479204d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479204dLab Smp Id IC-SG1660L5_00013 Inj Date 30-SEP-2012 1807 Operator Inst ID PESTGC9iSmp Info SG1660L5_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 11 Calibration Sample Level 5Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2084 2085 -0001 34065069 250000 2100 8000- 12000 10000(M)

2526 2527 -0001 56733462 250000 2100 13324- 19985 16654

2775 2777 -0002 42475382 250000 2400 9975- 14963 12469

3127 3130 -0003 125050351 250000 2100 29367- 44051 36709

3328 3330 -0002 50069130 250000 2200 11758- 17638 14698

3681 3685 -0004 48815297 250000 2000 11464- 17196 14330

4043 4043 0000 50326849 250000 2200 11819- 17728 14774

4190 4191 -0001 23748661 250000 2300 5577- 8366 6972

Average of Peak Amounts = 219e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6071 6072 -0001 68912349 250000 2100 8000- 12000 10000

10162012Page 198 of 323

Data File vr479204d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6521 6522 -0001 126227611 250000 2100 14654- 21981 18317

6964 6964 0000 121529078 250000 2200 14108- 21162 17635

7164 7165 -0001 65183263 250000 2200 7567- 11351 9459

7601 7602 -0001 60754093 250000 2200 7053- 10579 8816

8892 8893 -0001 79243490 250000 2300 9199- 13799 11499

9114 9115 -0001 51279969 250000 2400 5953- 8930 7441

10153 10153 0000 40032694 250000 2300 4647- 6971 5809

Average of Peak Amounts = 223e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 83140007 200000 180 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 199 of 323

Data File vr479204d

Date 30-SEP-2012 1807

Client ID Instrument PESTGC9i

Sample Info SG1660L5_00013 Operator

10162012Page 200 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vf479205d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1221 Peak 1 16651595 - 17351665PCB-1221 Peak 2 21352065 - 22052135PCB-1221 Peak 3 26722602 - 27422672PCB-1221 Peak 4 28732803 - 29432873PCB-1221 Peak 5 29612891 - 30312961PCB-1221 Peak 6 37393669 - 38093739PCB-1221 Peak 7 40834013 - 41534083PCB-1221 Peak 8 44774407 - 45474477

FORM VI 8082 10162012Page 201 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992612 vf479205d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

47106PCB-1221 Peak 1 Ave 20047106130012961PCB-1221 Peak 2 Ave 20012960750058524PCB-1221 Peak 3 Ave 20058523710040015PCB-1221 Peak 4 Ave 20040015420013789PCB-1221 Peak 5 Ave 20013788908018488PCB-1221 Peak 6 Ave 20018488040061501PCB-1221 Peak 7 Ave 20061500800024165PCB-1221 Peak 8 Ave 200241652800

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 202 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vf479205d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1221 Peak 1 Ave 4710613 1000PCB-1221 Peak 2 Ave 1296075 1000PCB-1221 Peak 3 Ave 5852371 1000PCB-1221 Peak 4 Ave 4001542 1000PCB-1221 Peak 5 Ave 13788908 1000PCB-1221 Peak 6 Ave 1848804 1000PCB-1221 Peak 7 Ave 615008 1000PCB-1221 Peak 8 Ave 2416528 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 203 of 323

Data File vf479205d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479205dLab Smp Id IC-SG1221L3_00014 Inj Date 30-SEP-2012 1822 Operator Inst ID PESTGC9iSmp Info ic SG1221L3_00014Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 12 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12210subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

22 Aroclor-1221 CAS 11104-28-2

1665 1665 0000 4710613 100000 1000 8000- 12000 10000

2135 2135 0000 1296075 100000 1000 2201- 3302 2751

2672 2672 0000 5852371 100000 1000 9939- 14909 12424

2873 2873 0000 4001542 100000 1000 6796- 10194 8495

2961 2961 0000 13788908 100000 1000 23418- 35126 29272

3739 3739 0000 1848804 100000 1000 3140- 4710 3925

4083 4083 0000 615008 100000 1000 1044- 1567 1306

4477 4477 0000 2416528 100000 1000 4104- 6156 5130

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 204 of 323

Data File vf479205d

Date 30-SEP-2012 1822

Client ID Instrument PESTGC9i

Sample Info ic SG1221L3_00014 Operator

10162012Page 205 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vr479205d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1221 Peak 1 11111041 - 11811111PCB-1221 Peak 2 15111441 - 15811511PCB-1221 Peak 3 18601790 - 19301860PCB-1221 Peak 4 20822012 - 21522082PCB-1221 Peak 5 25282458 - 25982528PCB-1221 Peak 6 26022532 - 26722602PCB-1221 Peak 7 26852615 - 27552685PCB-1221 Peak 8 31303060 - 32003130

FORM VI 8082 10162012Page 206 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992612 vr479205d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

64024PCB-1221 Peak 1 Ave 20064024020030571PCB-1221 Peak 2 Ave 20030571000095270PCB-1221 Peak 3 Ave 20095269770024981PCB-1221 Peak 4 Ave 20024981158027336PCB-1221 Peak 5 Ave 20027336400022123PCB-1221 Peak 6 Ave 20022122590041633PCB-1221 Peak 7 Ave 20041632790048909PCB-1221 Peak 8 Ave 200489094700

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 207 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vr479205d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1221 Peak 1 Ave 6402402 1000PCB-1221 Peak 2 Ave 3057100 1000PCB-1221 Peak 3 Ave 9526977 1000PCB-1221 Peak 4 Ave 24981158 1000PCB-1221 Peak 5 Ave 2733640 1000PCB-1221 Peak 6 Ave 2212259 1000PCB-1221 Peak 7 Ave 4163279 1000PCB-1221 Peak 8 Ave 4890947 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 208 of 323

Data File vr479205d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479205dLab Smp Id IC-SG1221L3_00014 Inj Date 30-SEP-2012 1822 Operator Inst ID PESTGC9iSmp Info ic SG1221L3_00014Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 12 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12210subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

22 Aroclor-1221 CAS 11104-28-2

1111 1111 0000 6402402 100000 1000 8000- 12000 10000(M)

1511 1511 0000 3057100 100000 1000 3820- 5730 4775

1860 1860 0000 9526977 100000 1000 11904- 17856 14880

2082 2082 0000 24981158 100000 1000 31215- 46822 39018

2528 2528 0000 2733640 100000 1000 3416- 5124 4270

2602 2602 0000 2212259 100000 1000 2764- 4146 3455

2685 2685 0000 4163279 100000 1000 5202- 7803 6503

3130 3130 0000 4890947 100000 1000 6111- 9167 7639

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 209 of 323

Data File vr479205d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 210 of 323

Data File vr479205d

Date 30-SEP-2012 1822

Client ID Instrument PESTGC9i

Sample Info ic SG1221L3_00014 Operator

10162012Page 211 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vf479206d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1232 Peak 1 29612891 - 30312961PCB-1232 Peak 2 36403570 - 37103640PCB-1232 Peak 3 40854015 - 41554085PCB-1232 Peak 4 47224652 - 47924722PCB-1232 Peak 5 49024832 - 49724902PCB-1232 Peak 6 50875017 - 51575087PCB-1232 Peak 7 55425472 - 56125542PCB-1232 Peak 8 57515681 - 58215751

FORM VI 8082 10162012Page 212 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992613 vf479206d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

97711PCB-1232 Peak 1 Ave 20097710620094688PCB-1232 Peak 2 Ave 20094688030035761PCB-1232 Peak 3 Ave 20035761260066995PCB-1232 Peak 4 Ave 20066994820050607PCB-1232 Peak 5 Ave 20050607280041053PCB-1232 Peak 6 Ave 20041053380057396PCB-1232 Peak 7 Ave 20057395890062677PCB-1232 Peak 8 Ave 200626765000

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 213 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vf479206d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1232 Peak 1 Ave 9771062 1000PCB-1232 Peak 2 Ave 9468803 1000PCB-1232 Peak 3 Ave 3576126 1000PCB-1232 Peak 4 Ave 6699482 1000PCB-1232 Peak 5 Ave 5060728 1000PCB-1232 Peak 6 Ave 4105338 1000PCB-1232 Peak 7 Ave 5739589 1000PCB-1232 Peak 8 Ave 6267650 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 214 of 323

Data File vf479206d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479206dLab Smp Id ic SG1232L3_00013 Inj Date 30-SEP-2012 1838 Operator Inst ID PESTGC9iSmp Info ic SG1232L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 13 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12320subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

23 Aroclor-1232 CAS 11141-16-5

2961 2961 0000 9771062 100000 1000 8000- 12000 10000

3640 3640 0000 9468803 100000 1000 7753- 11629 9691

4085 4085 0000 3576126 100000 1000 2928- 4392 3660

4722 4722 0000 6699482 100000 1000 5485- 8228 6856

4902 4902 0000 5060728 100000 1000 4143- 6215 5179

5087 5087 0000 4105338 100000 1000 3361- 5042 4202

5542 5542 0000 5739589 100000 1000 4699- 7049 5874

5751 5751 0000 6267650 100000 1000 5132- 7697 6415

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 215 of 323

Data File vf479206d

Date 30-SEP-2012 1838

Client ID Instrument PESTGC9i

Sample Info ic SG1232L3_00013 Operator

10162012Page 216 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vr479206d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1232 Peak 1 20822012 - 21522082PCB-1232 Peak 2 25262456 - 25962526PCB-1232 Peak 3 27762706 - 28462776PCB-1232 Peak 4 31283058 - 31983128PCB-1232 Peak 5 33293259 - 33993329PCB-1232 Peak 6 34243354 - 34943424PCB-1232 Peak 7 40423972 - 41124042PCB-1232 Peak 8 46144544 - 46844614

FORM VI 8082 10162012Page 217 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992613 vr479206d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

18402PCB-1232 Peak 1 Ave 20018402354014182PCB-1232 Peak 2 Ave 20014181613010089PCB-1232 Peak 3 Ave 20010089309027669PCB-1232 Peak 4 Ave 20027669356010841PCB-1232 Peak 5 Ave 20010840936085833PCB-1232 Peak 6 Ave 20085833230011581PCB-1232 Peak 7 Ave 20011580551048393PCB-1232 Peak 8 Ave 200483934800

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 218 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vr479206d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1232 Peak 1 Ave 18402354 1000PCB-1232 Peak 2 Ave 14181613 1000PCB-1232 Peak 3 Ave 10089309 1000PCB-1232 Peak 4 Ave 27669356 1000PCB-1232 Peak 5 Ave 10840936 1000PCB-1232 Peak 6 Ave 8583323 1000PCB-1232 Peak 7 Ave 11580551 1000PCB-1232 Peak 8 Ave 4839348 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 219 of 323

Data File vr479206d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479206dLab Smp Id ic SG1232L3_00013 Inj Date 30-SEP-2012 1838 Operator Inst ID PESTGC9iSmp Info ic SG1232L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 13 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12320subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

23 Aroclor-1232 CAS 11141-16-5

2082 2082 0000 18402354 100000 1000 8000- 12000 10000

2526 2526 0000 14181613 100000 1000 6165- 9248 7706

2776 2776 0000 10089309 100000 1000 4386- 6579 5483

3128 3128 0000 27669356 100000 1000 12029- 18043 15036

3329 3329 0000 10840936 100000 1000 4713- 7069 5891

3424 3424 0000 8583323 100000 1000 3731- 5597 4664

4042 4042 0000 11580551 100000 1000 5034- 7552 6293

4614 4614 0000 4839348 100000 1000 2104- 3156 2630

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 220 of 323

Data File vr479206d

Date 30-SEP-2012 1838

Client ID Instrument PESTGC9i

Sample Info ic SG1232L3_00013 Operator

10162012Page 221 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vf479207d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1242 Peak 1 29612891 - 30312961PCB-1242 Peak 2 36413571 - 37113641PCB-1242 Peak 3 40864016 - 41564086PCB-1242 Peak 4 44794409 - 45494479PCB-1242 Peak 5 47234653 - 47934723PCB-1242 Peak 6 51585088 - 52285158PCB-1242 Peak 7 57525682 - 58225752PCB-1242 Peak 8 62656195 - 63356265

FORM VI 8082 10162012Page 222 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992614 vf479207d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

81414PCB-1242 Peak 1 Ave 20081414290015365PCB-1242 Peak 2 Ave 20015365311065982PCB-1242 Peak 3 Ave 20065981950028106PCB-1242 Peak 4 Ave 20028106459012209PCB-1242 Peak 5 Ave 20012208628069961PCB-1242 Peak 6 Ave 20069960990010615PCB-1242 Peak 7 Ave 20010615499010283PCB-1242 Peak 8 Ave 200102828980

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 223 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vf479207d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1242 Peak 1 Ave 8141429 1000PCB-1242 Peak 2 Ave 15365311 1000PCB-1242 Peak 3 Ave 6598195 1000PCB-1242 Peak 4 Ave 28106459 1000PCB-1242 Peak 5 Ave 12208628 1000PCB-1242 Peak 6 Ave 6996099 1000PCB-1242 Peak 7 Ave 10615499 1000PCB-1242 Peak 8 Ave 10282898 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 224 of 323

Data File vf479207d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479207dLab Smp Id ic SG1242L3_00013 Inj Date 30-SEP-2012 1854 Operator Inst ID PESTGC9iSmp Info ic SG1242L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 14 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12420subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

24 Aroclor-1242 CAS 53469-21-9

2961 2961 0000 8141429 100000 1000 8000- 12000 10000(M)

3641 3641 0000 15365311 100000 1000 15098- 22648 18873

4086 4086 0000 6598195 100000 1000 6484- 9725 8104

4479 4479 0000 28106459 100000 1000 27618- 41427 34523

4723 4723 0000 12208628 100000 1000 11997- 17995 14996

5158 5158 0000 6996099 100000 1000 6875- 10312 8593

5752 5752 0000 10615499 100000 1000 10431- 15647 13039

6265 6265 0000 10282898 100000 1000 10104- 15156 12630

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 225 of 323

Data File vf479207d Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 226 of 323

Data File vf479207d

Date 30-SEP-2012 1854

Client ID Instrument PESTGC9i

Sample Info ic SG1242L3_00013 Operator

10162012Page 227 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vr479207d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1242 Peak 1 20832013 - 21532083PCB-1242 Peak 2 25272457 - 25972527PCB-1242 Peak 3 27772707 - 28472777PCB-1242 Peak 4 31293059 - 31993129PCB-1242 Peak 5 33293259 - 33993329PCB-1242 Peak 6 36853615 - 37553685PCB-1242 Peak 7 40443974 - 41144044PCB-1242 Peak 8 51265056 - 51965126

FORM VI 8082 10162012Page 228 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992614 vr479207d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

13527PCB-1242 Peak 1 Ave 20013526845020219PCB-1242 Peak 2 Ave 20020218998014340PCB-1242 Peak 3 Ave 20014339987044262PCB-1242 Peak 4 Ave 20044261735017388PCB-1242 Peak 5 Ave 20017387684018314PCB-1242 Peak 6 Ave 20018314121017750PCB-1242 Peak 7 Ave 20017749733015393PCB-1242 Peak 8 Ave 200153932670

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 229 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vr479207d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1242 Peak 1 Ave 13526845 1000PCB-1242 Peak 2 Ave 20218998 1000PCB-1242 Peak 3 Ave 14339987 1000PCB-1242 Peak 4 Ave 44261735 1000PCB-1242 Peak 5 Ave 17387684 1000PCB-1242 Peak 6 Ave 18314121 1000PCB-1242 Peak 7 Ave 17749733 1000PCB-1242 Peak 8 Ave 15393267 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 230 of 323

Data File vr479207d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479207dLab Smp Id ic SG1242L3_00013 Inj Date 30-SEP-2012 1854 Operator Inst ID PESTGC9iSmp Info ic SG1242L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 14 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12420subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

24 Aroclor-1242 CAS 53469-21-9

2083 2083 0000 13526845 100000 1000 8000- 12000 10000(M)

2527 2527 0000 20218998 100000 1000 11958- 17937 14947

2777 2777 0000 14339987 100000 1000 8481- 12721 10601

3129 3129 0000 44261735 100000 1000 26177- 39266 32721

3329 3329 0000 17387684 100000 1000 10283- 15425 12854

3685 3685 0000 18314121 100000 1000 10831- 16247 13539

4044 4044 0000 17749733 100000 1000 10497- 15746 13122

5126 5126 0000 15393267 100000 1000 9104- 13656 11380

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 231 of 323

Data File vr479207d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 232 of 323

Data File vr479207d

Date 30-SEP-2012 1854

Client ID Instrument PESTGC9i

Sample Info ic SG1242L3_00013 Operator

10162012Page 233 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vf479208d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1248 Peak 1 36373567 - 37073637PCB-1248 Peak 2 44734403 - 45434473PCB-1248 Peak 3 49514881 - 50214951PCB-1248 Peak 4 50865016 - 51565086PCB-1248 Peak 5 55415471 - 56115541PCB-1248 Peak 6 57505680 - 58205750PCB-1248 Peak 7 61916121 - 62616191PCB-1248 Peak 8 62626192 - 63326262

FORM VI 8082 10162012Page 234 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992615 vf479208d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

89356PCB-1248 Peak 1 Ave 20089355610020760PCB-1248 Peak 2 Ave 20020759623031559PCB-1248 Peak 3 Ave 20031559070012341PCB-1248 Peak 4 Ave 20012341389015809PCB-1248 Peak 5 Ave 20015808884017466PCB-1248 Peak 6 Ave 20017465791016624PCB-1248 Peak 7 Ave 20016623508019431PCB-1248 Peak 8 Ave 200194311040

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 235 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vf479208d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1248 Peak 1 Ave 8935561 1000PCB-1248 Peak 2 Ave 20759623 1000PCB-1248 Peak 3 Ave 3155907 1000PCB-1248 Peak 4 Ave 12341389 1000PCB-1248 Peak 5 Ave 15808884 1000PCB-1248 Peak 6 Ave 17465791 1000PCB-1248 Peak 7 Ave 16623508 1000PCB-1248 Peak 8 Ave 19431104 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 236 of 323

Data File vf479208d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479208dLab Smp Id ic SG1248L3_00013 Inj Date 30-SEP-2012 1909 Operator Inst ID PESTGC9iSmp Info ic SG1248L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 15 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12480subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

25 Aroclor-1248 CAS 12672-29-6

3637 3637 0000 8935561 100000 1000 8000- 12000 10000

4473 4473 0000 20759623 100000 1000 18586- 27879 23233

4951 4951 0000 3155907 100000 1000 2825- 4238 3532

5086 5086 0000 12341389 100000 1000 11049- 16574 13812

5541 5541 0000 15808884 100000 1000 14154- 21231 17692

5750 5750 0000 17465791 100000 1000 15637- 23456 19546

6191 6191 0000 16623508 100000 1000 14883- 22325 18604

6262 6262 0000 19431104 100000 1000 17397- 26095 21746

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 237 of 323

Data File vf479208d

Date 30-SEP-2012 1909

Client ID Instrument PESTGC9i

Sample Info ic SG1248L3_00013 Operator

10162012Page 238 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vr479208d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1248 Peak 1 25252455 - 25952525PCB-1248 Peak 2 31243054 - 31943124PCB-1248 Peak 3 34233353 - 34933423PCB-1248 Peak 4 36783608 - 37483678PCB-1248 Peak 5 40413971 - 41114041PCB-1248 Peak 6 41864116 - 42564186PCB-1248 Peak 7 46154545 - 46854615PCB-1248 Peak 8 51245054 - 51945124

FORM VI 8082 10162012Page 239 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992615 vr479208d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

11417PCB-1248 Peak 1 Ave 20011416682034274PCB-1248 Peak 2 Ave 20034273988063635PCB-1248 Peak 3 Ave 20063635020034030PCB-1248 Peak 4 Ave 20034030097030220PCB-1248 Peak 5 Ave 20030220358018203PCB-1248 Peak 6 Ave 20018202681015611PCB-1248 Peak 7 Ave 20015610993034370PCB-1248 Peak 8 Ave 200343696460

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 240 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vr479208d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1248 Peak 1 Ave 11416682 1000PCB-1248 Peak 2 Ave 34273988 1000PCB-1248 Peak 3 Ave 6363502 1000PCB-1248 Peak 4 Ave 34030097 1000PCB-1248 Peak 5 Ave 30220358 1000PCB-1248 Peak 6 Ave 18202681 1000PCB-1248 Peak 7 Ave 15610993 1000PCB-1248 Peak 8 Ave 34369646 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 241 of 323

Data File vr479208d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479208dLab Smp Id ic SG1248L3_00013 Inj Date 30-SEP-2012 1909 Operator Inst ID PESTGC9iSmp Info ic SG1248L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 15 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12480subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

25 Aroclor-1248 CAS 12672-29-6

2525 2525 0000 11416682 100000 1000 8000- 12000 10000(M)

3124 3124 0000 34273988 100000 1000 24017- 36025 30021

3423 3423 0000 6363502 100000 1000 4459- 6689 5574

3678 3678 0000 34030097 100000 1000 23846- 35769 29807

4041 4041 0000 30220358 100000 1000 21176- 31764 26470

4186 4186 0000 18202681 100000 1000 12755- 19133 15944

4615 4615 0000 15610993 100000 1000 10939- 16409 13674

5124 5124 0000 34369646 100000 1000 24084- 36126 30105

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 242 of 323

Data File vr479208d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 243 of 323

Data File vr479208d

Date 30-SEP-2012 1909

Client ID Instrument PESTGC9i

Sample Info ic SG1248L3_00013 Operator

10162012Page 244 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vf479209d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1254 Peak 1 50855015 - 51555085PCB-1254 Peak 2 62536183 - 63236253PCB-1254 Peak 3 65806510 - 66506580PCB-1254 Peak 4 71577087 - 72277157PCB-1254 Peak 5 73717301 - 74417371PCB-1254 Peak 6 85968526 - 86668596PCB-1254 Peak 7 90869016 - 91569086PCB-1254 Peak 8 98439773 - 99139843

FORM VI 8082 10162012Page 245 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992616 vf479209d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

97124PCB-1254 Peak 1 Ave 20097124230016374PCB-1254 Peak 2 Ave 20016373834017590PCB-1254 Peak 3 Ave 20017589776013684PCB-1254 Peak 4 Ave 20013683949027505PCB-1254 Peak 5 Ave 20027504947017262PCB-1254 Peak 6 Ave 20017261880028714PCB-1254 Peak 7 Ave 20028713900074774PCB-1254 Peak 8 Ave 200747739500

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 246 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vf479209d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1254 Peak 1 Ave 9712423 1000PCB-1254 Peak 2 Ave 16373834 1000PCB-1254 Peak 3 Ave 17589776 1000PCB-1254 Peak 4 Ave 13683949 1000PCB-1254 Peak 5 Ave 27504947 1000PCB-1254 Peak 6 Ave 17261880 1000PCB-1254 Peak 7 Ave 28713900 1000PCB-1254 Peak 8 Ave 7477395 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 247 of 323

Data File vf479209d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479209dLab Smp Id ic SG1254L3_00013 Inj Date 30-SEP-2012 1925 Operator Inst ID PESTGC9iSmp Info ic SG1254L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 16 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12540subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

26 Aroclor-1254 CAS 11097-69-1

5085 5085 0000 9712423 100000 1000 8000- 12000 10000

6253 6253 0000 16373834 100000 1000 13487- 20230 16859

6580 6580 0000 17589776 100000 1000 14488- 21733 18111

7157 7157 0000 13683949 100000 1000 11271- 16907 14089

7371 7371 0000 27504947 100000 1000 22655- 33983 28319

8596 8596 0000 17261880 100000 1000 14218- 21328 17773

9086 9086 0000 28713900 100000 1000 23651- 35477 29564

9843 9843 0000 7477395 100000 1000 6159- 9239 7699

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 248 of 323

Data File vf479209d

Date 30-SEP-2012 1925

Client ID Instrument PESTGC9i

Sample Info ic SG1254L3_00013 Operator

10162012Page 249 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vr479209d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1254 Peak 1 46874617 - 47574687PCB-1254 Peak 2 47624692 - 48324762PCB-1254 Peak 3 51285058 - 51985128PCB-1254 Peak 4 55695499 - 56395569PCB-1254 Peak 5 57705700 - 58405770PCB-1254 Peak 6 62216151 - 62916221PCB-1254 Peak 7 65216451 - 65916521PCB-1254 Peak 8 69656895 - 70356965

FORM VI 8082 10162012Page 250 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992616 vr479209d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

24886PCB-1254 Peak 1 Ave 20024885981024126PCB-1254 Peak 2 Ave 20024125717033197PCB-1254 Peak 3 Ave 20033196979024470PCB-1254 Peak 4 Ave 20024470162043009PCB-1254 Peak 5 Ave 20043008616038112PCB-1254 Peak 6 Ave 20038111884031186PCB-1254 Peak 7 Ave 20031186488041987PCB-1254 Peak 8 Ave 200419870070

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 251 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vr479209d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1254 Peak 1 Ave 24885981 1000PCB-1254 Peak 2 Ave 24125717 1000PCB-1254 Peak 3 Ave 33196979 1000PCB-1254 Peak 4 Ave 24470162 1000PCB-1254 Peak 5 Ave 43008616 1000PCB-1254 Peak 6 Ave 38111884 1000PCB-1254 Peak 7 Ave 31186488 1000PCB-1254 Peak 8 Ave 41987007 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 252 of 323

Data File vr479209d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479209dLab Smp Id ic SG1254L3_00013 Inj Date 30-SEP-2012 1925 Operator Inst ID PESTGC9iSmp Info ic SG1254L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 16 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12540subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

26 Aroclor-1254 CAS 11097-69-1

4687 4687 0000 24885981 100000 1000 8000- 12000 10000(M)

4762 4762 0000 24125717 100000 1000 7756- 11633 9695

5128 5128 0000 33196979 100000 1000 10672- 16008 13340

5569 5569 0000 24470162 100000 1000 7866- 11799 9833

5770 5770 0000 43008616 100000 1000 13826- 20739 17282

6221 6221 0000 38111884 100000 1000 12252- 18378 15315

6521 6521 0000 31186488 100000 1000 10025- 15038 12532

6965 6965 0000 41987007 100000 1000 13497- 20246 16872

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 253 of 323

Data File vr479209d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 254 of 323

Data File vr479209d

Date 30-SEP-2012 1925

Client ID Instrument PESTGC9i

Sample Info ic SG1254L3_00013 Operator

10162012Page 255 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-2

TestAmerica Edison

Lab File ID vf479493d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1005610273 979 1000 -21 150Ave

PCB-1016 Peak 2 2214321113 1050 1000 49 150Ave

PCB-1016 Peak 3 96058714 1100 1000 102 150Ave

PCB-1016 Peak 4 4004137710 1060 1000 62 150Ave

PCB-1016 Peak 5 1906116455 1160 1000 158 150Ave

PCB-1016 Peak 6 104069770 1070 1000 65 150Ave

PCB-1016 Peak 7 1271211990 1060 1000 60 150Ave

PCB-1016 Peak 8 1381712146 1140 1000 138 150Ave

PCB-1260 Peak 1 2403322106 1090 1000 87 150Ave

PCB-1260 Peak 2 2694125092 1070 1000 74 150Ave

PCB-1260 Peak 3 4112136867 1120 1000 115 150Ave

PCB-1260 Peak 4 1829116241 1130 1000 126 150Ave

PCB-1260 Peak 5 102408814 1160 1000 162 150Ave

PCB-1260 Peak 6 1863416926 1100 1000 101 150Ave

PCB-1260 Peak 7 2108721064 1000 1000 01 150Ave

PCB-1260 Peak 8 80147857 1020 1000 20 150Ave

DCB Decachlorobiphenyl 267686265963 101 100 06 150Ave

FORM VII 8082

10162012Page 256 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-2

TestAmerica Edison

Lab File ID vf479493d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 292 289 303

PCB-1016 Peak 2 359 357 371

PCB-1016 Peak 3 404 401 415

PCB-1016 Peak 4 443 441 455

PCB-1016 Peak 5 468 465 479

PCB-1016 Peak 6 511 509 523

PCB-1016 Peak 7 550 547 561

PCB-1016 Peak 8 571 568 582

PCB-1260 Peak 1 771 769 783

PCB-1260 Peak 2 816 814 828

PCB-1260 Peak 3 902 901 915

PCB-1260 Peak 4 928 926 940

PCB-1260 Peak 5 940 938 952

PCB-1260 Peak 6 986 983 997

PCB-1260 Peak 7 1059 1055 1069

PCB-1260 Peak 8 1106 1102 1116

DCB Decachlorobiphenyl 1149 1141 1161

Form VII 8082

10162012Page 257 of 323

Data File vf479493d Report Date 09-Oct-2012 0318

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479493dLab Smp Id ccvrtsg1660l3_00019 Inj Date 08-OCT-2012 1830 Operator Inst ID PESTGC9iSmp Info ccvrt-sg1660l3_00019Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 21 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2923 2961 -0038 10055641 978875 650 8000- 12000 10000(M)

3593 3641 -0048 22143043 104879 700 16892- 25338 22021

4036 4085 -0049 9604932 110224 730 6889- 10334 9552

4432 4479 -0047 40041013 106181 710 30481- 45721 39819

4678 4722 -0044 19061275 115840 770 13320- 19980 18956

5114 5158 -0044 10405886 106506 710 7564- 11346 10348

5500 5542 -0042 12711848 106020 710 9332- 13998 12642

5709 5752 -0043 13817418 113758 760 9784- 14675 13741

Average of Peak Concentrations = 720

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7706 7756 -0050 24033075 108715 720 8000- 12000 10000(M)

10162012Page 258 of 323

Data File vf479493d Report Date 09-Oct-2012 0318

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8161 8215 -0054 26941342 107369 720 9103- 13655 11210

9020 9084 -0064 41121424 111541 740 14090- 21136 17110

9276 9332 -0056 18291174 112626 750 6105- 9158 7611

9401 9454 -0053 10239798 116171 770 3460- 5190 4261

9861 9901 -0040 18634445 110097 730 6444- 9666 7754

10594 10616 -0022 21087197 100112 670 7926- 11889 12194

11063 11086 -0023 8014273 101999 680 2968- 4452 3335

Average of Peak Concentrations = 720

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11488 11515 -0027 26768608 100648 67 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 259 of 323

Data File vf479493d

Date 08-OCT-2012 1830

Client ID Instrument PESTGC9i

Sample Info ccvrt-sg1660l3_00019 Operator

10162012Page 260 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-1

TestAmerica Edison

Lab File ID vr479493d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1317915949 826 1000 -174 150Ave

PCB-1016 Peak 2 2492127231 915 1000 -85 150Ave

PCB-1016 Peak 3 1751817953 976 1000 -24 150Ave

PCB-1016 Peak 4 5583559495 938 1000 -62 150Ave

PCB-1016 Peak 5 2224122894 971 1000 -29 150Ave

PCB-1016 Peak 6 2383923697 1010 1000 06 150Ave

PCB-1016 Peak 7 2233922413 997 1000 -03 150Ave

PCB-1016 Peak 8 1103010158 1090 1000 86 150Ave

PCB-1260 Peak 1 3241432677 992 1000 -08 150Ave

PCB-1260 Peak 2 6068660467 1000 1000 04 150Ave

PCB-1260 Peak 3 5752255452 1040 1000 37 150Ave

PCB-1260 Peak 4 2973730164 986 1000 -14 150Ave

PCB-1260 Peak 5 2720927064 1010 1000 05 150Ave

PCB-1260 Peak 6 3391634367 987 1000 -13 150Ave

PCB-1260 Peak 7 2498721162 1180 1000 181 150Ave

PCB-1260 Peak 8 1900217245 1100 1000 102 150Ave

DCB Decachlorobiphenyl 482177470701 102 100 24 150Ave

FORM VII 8082

10162012Page 261 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-1

TestAmerica Edison

Lab File ID vr479493d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 206 201 215

PCB-1016 Peak 2 250 246 260

PCB-1016 Peak 3 275 271 285

PCB-1016 Peak 4 310 306 320

PCB-1016 Peak 5 330 326 340

PCB-1016 Peak 6 365 361 375

PCB-1016 Peak 7 401 397 411

PCB-1016 Peak 8 416 412 426

PCB-1260 Peak 1 604 600 614

PCB-1260 Peak 2 650 645 659

PCB-1260 Peak 3 694 689 703

PCB-1260 Peak 4 714 709 723

PCB-1260 Peak 5 757 753 767

PCB-1260 Peak 6 886 882 896

PCB-1260 Peak 7 908 904 918

PCB-1260 Peak 8 1013 1008 1022

DCB Decachlorobiphenyl 1061 1052 1072

Form VII 8082

10162012Page 262 of 323

Data File vr479493d Page 1 Report Date 09-Oct-2012 0318

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479493dLab Smp Id ccvrtsg1660l3_00019 Inj Date 08-OCT-2012 1830 Operator Inst ID PESTGC9iSmp Info ccvrt-sg1660l3_00019Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 21 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2056 2085 -0029 13178629 826281 550 8000- 12000 10000(M)

2498 2527 -0029 24921299 915181 610 13324- 19985 18910

2746 2777 -0031 17517717 975756 650 9975- 14963 13293

3100 3130 -0030 55834574 938480 620 29367- 44051 42368

3297 3330 -0033 22240639 971476 650 11758- 17638 16876

3648 3685 -0037 23838665 100597 670 11464- 17196 18089

4011 4043 -0032 22339236 996719 660 11819- 17728 16951

4157 4191 -0034 11029779 108584 720 5577- 8366 8369

Average of Peak Concentrations = 640

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6045 6072 -0027 32414247 991956 660 8000- 12000 10000(M)

10162012Page 263 of 323

Data File vr479493d Page 2 Report Date 09-Oct-2012 0318

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6496 6522 -0026 60686283 100362 670 14654- 21981 18722

6938 6964 -0026 57521890 103733 690 14108- 21162 17746

7137 7165 -0028 29736966 985849 660 7567- 11351 9174

7572 7602 -0030 27208663 100536 670 7053- 10579 8394

8857 8893 -0036 33916486 986885 660 9199- 13799 10463

9076 9115 -0039 24987061 118075 790 5953- 8930 7709

10135 10153 -0018 19001807 110187 730 4647- 6971 5862

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 48217685 102438 68 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 264 of 323

Data File vr479493d

Date 08-OCT-2012 1830

Client ID Instrument PESTGC9i

Sample Info ccvrt-sg1660l3_00019 Operator

10162012Page 265 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-2

TestAmerica Edison

Lab File ID vf479510d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 998310273 972 1000 -28 150Ave

PCB-1016 Peak 2 2182221113 1030 1000 34 150Ave

PCB-1016 Peak 3 93438714 1070 1000 72 150Ave

PCB-1016 Peak 4 3888937710 1030 1000 31 150Ave

PCB-1016 Peak 5 1831616455 1110 1000 113 150Ave

PCB-1016 Peak 6 100909770 1030 1000 33 150Ave

PCB-1016 Peak 7 1211711990 1010 1000 11 150Ave

PCB-1016 Peak 8 1287812146 1060 1000 60 150Ave

PCB-1260 Peak 1 2305022106 1040 1000 43 150Ave

PCB-1260 Peak 2 2601125092 1040 1000 37 150Ave

PCB-1260 Peak 3 4009636867 1090 1000 88 150Ave

PCB-1260 Peak 4 1793216241 1100 1000 104 150Ave

PCB-1260 Peak 5 100168814 1140 1000 136 150Ave

PCB-1260 Peak 6 1799416926 1060 1000 63 150Ave

PCB-1260 Peak 7 2148621064 1020 1000 20 150Ave

PCB-1260 Peak 8 78557857 1000 1000 -00 150Ave

DCB Decachlorobiphenyl 262499265963 987 100 -13 150Ave

FORM VII 8082

10162012Page 266 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-2

TestAmerica Edison

Lab File ID vf479510d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 292 289 303

PCB-1016 Peak 2 359 357 371

PCB-1016 Peak 3 403 401 415

PCB-1016 Peak 4 443 441 455

PCB-1016 Peak 5 468 465 479

PCB-1016 Peak 6 511 509 523

PCB-1016 Peak 7 550 547 561

PCB-1016 Peak 8 571 568 582

PCB-1260 Peak 1 770 769 783

PCB-1260 Peak 2 816 814 828

PCB-1260 Peak 3 902 901 915

PCB-1260 Peak 4 927 926 940

PCB-1260 Peak 5 940 938 952

PCB-1260 Peak 6 986 983 997

PCB-1260 Peak 7 1059 1055 1069

PCB-1260 Peak 8 1106 1102 1116

DCB Decachlorobiphenyl 1149 1141 1161

Form VII 8082

10162012Page 267 of 323

Data File vf479510d Report Date 09-Oct-2012 0335

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479510dLab Smp Id ccv-SG1660L3_00019 Inj Date 09-OCT-2012 0147 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 40 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2922 2961 -0039 9983429 971845 650 8000- 12000 10000(M)

3591 3641 -0050 21822420 103360 690 16892- 25338 21859

4034 4085 -0051 9342806 107216 710 6889- 10334 9358

4431 4479 -0048 38888611 103125 690 30481- 45721 38953

4677 4722 -0045 18315559 111308 740 13320- 19980 18346

5112 5158 -0046 10089629 103269 690 7564- 11346 10106

5497 5542 -0045 12117410 101063 670 9332- 13998 12138

5706 5752 -0046 12878214 106025 710 9784- 14675 12900

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7703 7756 -0053 23050032 104269 700 8000- 12000 10000(M)

10162012Page 268 of 323

Data File vf479510d Report Date 09-Oct-2012 0335

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8159 8215 -0056 26011086 103662 690 9103- 13655 11285

9017 9084 -0067 40095841 108759 720 14090- 21136 17395

9273 9332 -0059 17931794 110413 740 6105- 9158 7780

9399 9454 -0055 10016237 113634 760 3460- 5190 4345

9858 9901 -0043 17994170 106314 710 6444- 9666 7807

10594 10616 -0022 21485546 102003 680 7926- 11889 12478

11061 11086 -0025 7855172 999743 670 2968- 4452 3408

Average of Peak Concentrations = 710

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11485 11515 -0030 26249946 986977 66 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 269 of 323

Data File vf479510d

Date 09-OCT-2012 0147

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 270 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-1

TestAmerica Edison

Lab File ID vr479510d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1577315949 989 1000 -11 150Ave

PCB-1016 Peak 2 2637627231 969 1000 -31 150Ave

PCB-1016 Peak 3 1911517953 1060 1000 65 150Ave

PCB-1016 Peak 4 5729159495 963 1000 -37 150Ave

PCB-1016 Peak 5 2290722894 1000 1000 00 150Ave

PCB-1016 Peak 6 2510823697 1060 1000 60 150Ave

PCB-1016 Peak 7 2349222413 1050 1000 48 150Ave

PCB-1016 Peak 8 1095310158 1080 1000 78 150Ave

PCB-1260 Peak 1 3177332677 972 1000 -28 150Ave

PCB-1260 Peak 2 5864160467 970 1000 -30 150Ave

PCB-1260 Peak 3 5561155452 1000 1000 03 150Ave

PCB-1260 Peak 4 2920530164 968 1000 -32 150Ave

PCB-1260 Peak 5 2692527064 995 1000 -05 150Ave

PCB-1260 Peak 6 3316834367 965 1000 -35 150Ave

PCB-1260 Peak 7 2309521162 1090 1000 91 150Ave

PCB-1260 Peak 8 1649517245 957 1000 -43 150Ave

DCB Decachlorobiphenyl 444399470701 944 100 -56 150Ave

FORM VII 8082

10162012Page 271 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-1

TestAmerica Edison

Lab File ID vr479510d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 206 201 215

PCB-1016 Peak 2 250 246 260

PCB-1016 Peak 3 275 271 285

PCB-1016 Peak 4 310 306 320

PCB-1016 Peak 5 330 326 340

PCB-1016 Peak 6 365 361 375

PCB-1016 Peak 7 401 397 411

PCB-1016 Peak 8 416 412 426

PCB-1260 Peak 1 604 600 614

PCB-1260 Peak 2 649 645 659

PCB-1260 Peak 3 694 689 703

PCB-1260 Peak 4 714 709 723

PCB-1260 Peak 5 757 753 767

PCB-1260 Peak 6 885 882 896

PCB-1260 Peak 7 907 904 918

PCB-1260 Peak 8 1013 1008 1022

DCB Decachlorobiphenyl 1061 1052 1072

Form VII 8082

10162012Page 272 of 323

Data File vr479510d Page 1 Report Date 09-Oct-2012 0335

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479510dLab Smp Id ccv-SG1660L3_00019 Inj Date 09-OCT-2012 0147 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 40 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2056 2085 -0029 15772630 988922 660 8000- 12000 10000(M)

2498 2527 -0029 26375750 968593 640 13324- 19985 16722

2747 2777 -0030 19114706 106471 710 9975- 14963 12119

3099 3130 -0031 57290957 962959 640 29367- 44051 36323

3296 3330 -0034 22907341 100060 670 11758- 17638 14523

3645 3685 -0040 25108132 105954 710 11464- 17196 15919

4009 4043 -0034 23491941 104815 700 11819- 17728 14894

4155 4191 -0036 10952986 107828 720 5577- 8366 6944

Average of Peak Concentrations = 680

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6043 6072 -0029 31772880 972329 650 8000- 12000 10000(M)

10162012Page 273 of 323

Data File vr479510d Page 2 Report Date 09-Oct-2012 0335

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6494 6522 -0028 58641225 969803 650 14654- 21981 18456

6936 6964 -0028 55611337 100287 670 14108- 21162 17503

7135 7165 -0030 29205460 968228 640 7567- 11351 9192

7570 7602 -0032 26925453 994891 660 7053- 10579 8474

8854 8893 -0039 33168029 965107 640 9199- 13799 10439

9072 9115 -0043 23094940 109134 730 5953- 8930 7269

10132 10153 -0021 16495029 956510 640 4647- 6971 5192

Average of Peak Concentrations = 660

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 44439946 944122 63 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 274 of 323

Data File vr479510d

Date 09-OCT-2012 0147

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 275 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1309971-A

Matrix vf479496dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2208

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

88 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 276 of 323

Data File vf479496d Report Date 09-Oct-2012 0319

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479496dLab Smp Id MB 460-1309971-a Inj Date 08-OCT-2012 2208 Operator Inst ID PESTGC9iSmp Info MB 460-1309971-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 24 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11484 11515 -0031 23517325 884233 59 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 277 of 323

Data File vf479496d

Date 08-OCT-2012 2208

Client ID Instrument PESTGC9i

Sample Info MB 460-1309971-a Operator

10162012Page 278 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1309971-A

Matrix vr479496dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2208

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

97 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 279 of 323

Data File vr479496d Page 1 Report Date 09-Oct-2012 0319

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479496dLab Smp Id MB 460-1309971-a Inj Date 08-OCT-2012 2208 Operator Inst ID PESTGC9iSmp Info MB 460-1309971-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 24 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 45589434 968543 64 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 280 of 323

Data File vr479496d

Date 08-OCT-2012 2208

Client ID Instrument PESTGC9i

Sample Info MB 460-1309971-a Operator

10162012Page 281 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-1311371

Matrix vf479492dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10082012 1814Sample wtvol

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

114 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 282 of 323

Data File vf479492d Page 1 Report Date 09-Oct-2012 0317

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479492dLab Smp Id piblk-sgpiblk_00013 Inj Date 08-OCT-2012 1814 Operator Inst ID PESTGC9iSmp Info sgpiblk_00013Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 20 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11496 11515 -0019 6086041 228830 15 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 283 of 323

Data File vf479492d

Date 08-OCT-2012 1814

Client ID Instrument PESTGC9i

Sample Info sgpiblk_00013 Operator

10162012Page 284 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-1311371

Matrix vr479492dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10082012 1814Sample wtvol

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

114 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 285 of 323

Data File vr479492d Report Date 09-Oct-2012 0317

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479492dLab Smp Id piblk-sgpiblk_00013 Inj Date 08-OCT-2012 1814 Operator Inst ID PESTGC9iSmp Info sgpiblk_00013Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 20 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 10738471 228138 15 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 286 of 323

Data File vr479492d

Date 08-OCT-2012 1814

Client ID Instrument PESTGC9i

Sample Info sgpiblk_00013 Operator

10162012Page 287 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-13113718

Matrix vf479509dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10092012 0131Sample wtvol

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

122 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 288 of 323

Data File vf479509d Report Date 09-Oct-2012 0313

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479509dLab Smp Id SGPIBLK_00013 Inj Date 09-OCT-2012 0131 Operator Inst ID PESTGC9iSmp Info SGPIBLK_00013Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 39 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11487 11515 -0028 6469383 243244 16 8000- 12000 10000(a)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 289 of 323

Data File vf479509d

Date 09-OCT-2012 0131

Client ID Instrument PESTGC9i

Sample Info SGPIBLK_00013 Operator

10162012Page 290 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-13113718

Matrix vr479509dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10092012 0131Sample wtvol

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

102 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 291 of 323

Data File vr479509d Report Date 09-Oct-2012 0306

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479509dLab Smp Id SGPIBLK_00013 Inj Date 09-OCT-2012 0131 Operator Inst ID PESTGC9iSmp Info SGPIBLK_00013Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 39 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 9634357 204681 14 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 292 of 323

Data File vr479509d

Date 09-OCT-2012 0131

Client ID Instrument PESTGC9i

Sample Info SGPIBLK_00013 Operator

10162012Page 293 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1309972-A

Matrix vf479497dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2224

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 507

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 557

RECCAS NO LIMITSQSURROGATE

84 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 294 of 323

Data File vf479497d Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479497dLab Smp Id LCS 460-1309972-a Inj Date 08-OCT-2012 2224 Operator Inst ID PESTGC9iSmp Info LCS 460-1309972-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 25 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2926 2961 -0035 10792080 105056 700 8000- 12000 10000

3596 3641 -0045 23726579 112379 750 16892- 25338 21985

4040 4085 -0045 9881475 113398 760 6889- 10334 9156

4437 4479 -0042 42082916 111596 740 30481- 45721 38994

4683 4722 -0039 19556228 118847 790 13320- 19980 18121

5181 5158 0023 7863050 804795 540 7564- 11346 7286

5572 5542 0030 6208245 517785 340 9332- 13998 5753

5713 5752 -0039 14198514 116895 780 9784- 14675 13156

Average of Peak Concentrations = 680

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7711 7756 -0045 26515963 119947 800 8000- 12000 10000(M)

10162012Page 295 of 323

Data File vf479497d Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8168 8215 -0047 29809525 118800 790 9103- 13655 11242

9026 9084 -0058 46049501 124909 830 14090- 21136 17367

9283 9332 -0049 20194161 124344 830 6105- 9158 7616

9408 9454 -0046 11340121 128654 860 3460- 5190 4277

9864 9901 -0037 20709127 122354 820 6444- 9666 7810

10623 10616 0007 8913638 423178 280 7926- 11889 3362

11063 11086 -0023 8650385 110095 730 2968- 4452 3262

Average of Peak Concentrations = 740

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11484 11515 -0031 22216113 835308 56 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 296 of 323

Data File vf479497d

Date 08-OCT-2012 2224

Client ID Instrument PESTGC9i

Sample Info LCS 460-1309972-a Operator

10162012Page 297 of 323

Manual Integration Report

Data File vf479497dInj Date and Time 08-OCT-2012 2224Instrument ID PESTGC9iClient ID Compound 27 Aroclor-1260CAS 11096-82-5Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 776

Manual Integration Results

RT 771

Response 26515963

Amount 111428

Conc 74000

Manually Integrated By diazcManual Integration Reason

10162012Page 298 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1309972-A

Matrix vr479497dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2224

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 483

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 573

RECCAS NO LIMITSQSURROGATE

91 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 299 of 323

Data File vr479497d Page 1 Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479497dLab Smp Id LCS 460-1309972-a Inj Date 08-OCT-2012 2224 Operator Inst ID PESTGC9iSmp Info LCS 460-1309972-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 25 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2058 2085 -0027 15080112 945502 630 8000- 12000 10000(M)

2502 2527 -0025 26928755 988901 660 13324- 19985 17857

2750 2777 -0027 19042665 106070 710 9975- 14963 12628

3103 3130 -0027 59594211 100167 670 29367- 44051 39518

3301 3330 -0029 23808984 103998 690 11758- 17638 15788

3694 3685 0009 14297782 603352 400 11464- 17196 9481

4013 4043 -0030 24245185 108176 720 11819- 17728 16078

4188 4191 -0003 10255607 100963 670 5577- 8366 6801

Average of Peak Concentrations = 640

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6048 6072 -0024 36196886 110771 740 8000- 12000 10000

10162012Page 300 of 323

Data File vr479497d Page 2 Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6500 6522 -0022 67525585 111673 740 14654- 21981 18655

6943 6964 -0021 64479188 116279 780 14108- 21162 17813

7142 7165 -0023 33072749 109644 730 7567- 11351 9137

7578 7602 -0024 30577540 112984 750 7053- 10579 8448

8864 8893 -0029 38421619 111797 740 9199- 13799 10615

9083 9115 -0032 26202367 123818 820 5953- 8930 7239

10138 10153 -0015 20706585 120073 800 4647- 6971 5721

Average of Peak Concentrations = 760

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 42991277 913346 61 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 301 of 323

Data File vr479497d

Date 08-OCT-2012 2224

Client ID Instrument PESTGC9i

Sample Info LCS 460-1309972-a Operator

10162012Page 302 of 323

Manual Integration Report

Data File vr479497dInj Date and Time 08-OCT-2012 2224Instrument ID PESTGC9iClient ID Compound 21 Aroclor-1016CAS 12674-11-2Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 208

Manual Integration Results

RT 206

Response 15080112

Amount 96644

Conc 64000

Manually Integrated By diazcManual Integration Reason

10162012Page 303 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCSD 460-1309973-A

Matrix vf479498dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2239

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 516

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 583

RECCAS NO LIMITSQSURROGATE

99 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 304 of 323

Data File vf479498d Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479498dLab Smp Id LCSd 460-1309973-a Inj Date 08-OCT-2012 2239 Operator Inst ID PESTGC9iSmp Info LCSd 460-1309973-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 26 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2925 2961 -0036 10994509 107027 710 8000- 12000 10000

3594 3641 -0047 24222192 114726 760 16892- 25338 22031

4039 4085 -0046 9969671 114410 760 6889- 10334 9068

4435 4479 -0044 43128755 114369 760 30481- 45721 39228

4680 4722 -0042 19946065 121217 810 13320- 19980 18142

5177 5158 0019 7960960 814816 540 7564- 11346 7241

5569 5542 0027 6392667 533166 360 9332- 13998 5814

5711 5752 -0041 14546887 119763 800 9784- 14675 13231

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7708 7756 -0048 27193660 123013 820 8000- 12000 10000(M)

10162012Page 305 of 323

Data File vf479498d Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8164 8215 -0051 30632211 122078 810 9103- 13655 11264

9022 9084 -0062 47541251 128955 860 14090- 21136 17482

9278 9332 -0054 21062846 129693 860 6105- 9158 7745

9404 9454 -0050 11787377 133728 890 3460- 5190 4335

9862 9901 -0039 21547760 127309 850 6444- 9666 7924

10618 10616 0002 10677528 506919 340 7926- 11889 3926

11062 11086 -0024 9277293 118074 790 2968- 4452 3412

Average of Peak Concentrations = 780

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11482 11515 -0033 26307958 989158 66 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 306 of 323

Data File vf479498d

Date 08-OCT-2012 2239

Client ID Instrument PESTGC9i

Sample Info LCSd 460-1309973-a Operator

10162012Page 307 of 323

Manual Integration Report

Data File vf479498dInj Date and Time 08-OCT-2012 2239Instrument ID PESTGC9iClient ID Compound 27 Aroclor-1260CAS 11096-82-5Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 776

Manual Integration Results

RT 771

Response 27193660

Amount 116693

Conc 78000

Manually Integrated By diazcManual Integration Reason

10162012Page 308 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCSD 460-1309973-A

Matrix vr479498dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2239

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 497

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 595

RECCAS NO LIMITSQSURROGATE

108 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 309 of 323

Data File vr479498d Page 1 Report Date 09-Oct-2012 0321

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479498dLab Smp Id LCSd 460-1309973-a Inj Date 08-OCT-2012 2239 Operator Inst ID PESTGC9iSmp Info LCSd 460-1309973-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 26 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2058 2085 -0027 15401465 965650 640 8000- 12000 10000(M)

2501 2527 -0026 27477458 100905 670 13324- 19985 17841

2750 2777 -0027 19458638 108387 720 9975- 14963 12634

3102 3130 -0028 60672366 101979 680 29367- 44051 39394

3299 3330 -0031 24206974 105737 700 11758- 17638 15717

3679 3685 -0006 17478185 737562 490 11464- 17196 11348

4012 4043 -0031 24592091 109724 730 11819- 17728 15967

4189 4191 -0002 9970290 981538 650 5577- 8366 6474

Average of Peak Concentrations = 660

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6047 6072 -0025 36957605 113099 750 8000- 12000 10000

10162012Page 310 of 323

Data File vr479498d Page 2 Report Date 09-Oct-2012 0321

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6498 6522 -0024 69036402 114172 760 14654- 21981 18680

6940 6964 -0024 66037968 119090 790 14108- 21162 17869

7140 7165 -0025 33956993 112575 750 7567- 11351 9188

7575 7602 -0027 31643763 116923 780 7053- 10579 8562

8861 8893 -0032 40016219 116437 780 9199- 13799 10828

9080 9115 -0035 27744305 131104 870 5953- 8930 7507

10136 10153 -0017 22040150 127806 850 4647- 6971 5964

Average of Peak Concentrations = 790

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10612 10624 -0012 50942327 108226 72 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 311 of 323

Data File vr479498d

Date 08-OCT-2012 2239

Client ID Instrument PESTGC9i

Sample Info LCSd 460-1309973-a Operator

10162012Page 312 of 323

Manual Integration Report

Data File vr479498dInj Date and Time 08-OCT-2012 2239Instrument ID PESTGC9iClient ID Compound 21 Aroclor-1016CAS 12674-11-2Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 208

Manual Integration Results

RT 206

Response 15401465

Amount 99401

Conc 66000

Manually Integrated By diazcManual Integration Reason

10162012Page 313 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GC SEMI VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

PESTGC9

129926

Start Date

End Date 09302012 2043

09302012 1530

RINSE 460-1299261 CLP-2 053(mm)109302012 1530

RINSE 460-1299261 CLP-1 053(mm)109302012 1530

RINSE 460-1299262 CLP-2 053(mm)109302012 1546

RINSE 460-1299262 CLP-1 053(mm)109302012 1546

ZZZZZ CLP-2 053(mm)109302012 1602

ZZZZZ CLP-1 053(mm)109302012 1602

ZZZZZ CLP-2 053(mm)109302012 1617

ZZZZZ CLP-1 053(mm)109302012 1617

ZZZZZ CLP-2 053(mm)109302012 1633

ZZZZZ CLP-1 053(mm)109302012 1633

ZZZZZ CLP-2 053(mm)109302012 1649

ZZZZZ CLP-1 053(mm)109302012 1649

IC 460-1299267 CLP-2 053(mm)109302012 1704 vf479200d

IC 460-1299267 CLP-1 053(mm)109302012 1704 vr479200d

IC 460-1299268 CLP-2 053(mm)109302012 1720 vf479201d

IC 460-1299268 CLP-1 053(mm)109302012 1720 vr479201d

IC 460-1299269 CLP-2 053(mm)109302012 1735 vf479202d

IC 460-1299269 CLP-1 053(mm)109302012 1735 vr479202d

IC 460-12992610 CLP-2 053(mm)109302012 1751 vf479203d

IC 460-12992610 CLP-1 053(mm)109302012 1751 vr479203d

IC 460-12992611 CLP-2 053(mm)109302012 1807 vf479204d

IC 460-12992611 CLP-1 053(mm)109302012 1807 vr479204d

IC 460-12992612 CLP-2 053(mm)109302012 1822 vf479205d

IC 460-12992612 CLP-1 053(mm)109302012 1822 vr479205d

IC 460-12992613 CLP-2 053(mm)109302012 1838 vf479206d

IC 460-12992613 CLP-1 053(mm)109302012 1838 vr479206d

IC 460-12992614 CLP-2 053(mm)109302012 1854 vf479207d

IC 460-12992614 CLP-1 053(mm)109302012 1854 vr479207d

IC 460-12992615 CLP-2 053(mm)109302012 1909 vf479208d

IC 460-12992615 CLP-1 053(mm)109302012 1909 vr479208d

IC 460-12992616 CLP-2 053(mm)109302012 1925 vf479209d

IC 460-12992616 CLP-1 053(mm)109302012 1925 vr479209d

IC 460-12992617 CLP-2 053(mm)109302012 1940

IC 460-12992617 CLP-1 053(mm)109302012 1940

IC 460-12992618 CLP-2 053(mm)109302012 1956

IC 460-12992618 CLP-1 053(mm)109302012 1956

ZZZZZ CLP-2 053(mm)109302012 2011

ZZZZZ CLP-1 053(mm)109302012 2011

ZZZZZ CLP-2 053(mm)109302012 2027

ZZZZZ CLP-1 053(mm)109302012 2027

ZZZZZ CLP-2 053(mm)109302012 2043

ZZZZZ CLP-1 053(mm)109302012 2043

8082

10162012Page 314 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GC SEMI VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

PESTGC9

131137

Start Date

End Date 10092012 0147

10082012 1814

PIBLK 460-1311371 CLP-2 053(mm)110082012 1814 vf479492d

PIBLK 460-1311371 CLP-1 053(mm)110082012 1814 vr479492d

CCVRT 460-1311372 CLP-2 053(mm)110082012 1830 vf479493d

CCVRT 460-1311372 CLP-1 053(mm)110082012 1830 vr479493d

ZZZZZ CLP-2 053(mm)110082012 2137

ZZZZZ CLP-1 053(mm)110082012 2137

ZZZZZ CLP-2 053(mm)110082012 2152

ZZZZZ CLP-1 053(mm)110082012 2152

MB 460-1309971-A CLP-2 053(mm)110082012 2208 vf479496d

MB 460-1309971-A CLP-1 053(mm)110082012 2208 vr479496d

LCS 460-1309972-A CLP-2 053(mm)110082012 2224 vf479497d

LCS 460-1309972-A CLP-1 053(mm)110082012 2224 vr479497d

LCSD 460-1309973-A CLP-2 053(mm)110082012 2239 vf479498d

LCSD 460-1309973-A CLP-1 053(mm)110082012 2239 vr479498d

ZZZZZ CLP-2 053(mm)110082012 2255

ZZZZZ CLP-1 053(mm)110082012 2255

ZZZZZ CLP-2 053(mm)110082012 2311

ZZZZZ CLP-1 053(mm)110082012 2311

ZZZZZ CLP-2 053(mm)110082012 2326

ZZZZZ CLP-1 053(mm)110082012 2326

ZZZZZ CLP-2 053(mm)110082012 2342

ZZZZZ CLP-1 053(mm)110082012 2342

ZZZZZ CLP-2 053(mm)110082012 2358

ZZZZZ CLP-1 053(mm)110082012 2358

ZZZZZ CLP-2 053(mm)110092012 0013

ZZZZZ CLP-1 053(mm)110092012 0013

460-45537-1 WC-17338-100512-MW14-MM-251

CLP-2 053(mm)110092012 0029 vf479505d

460-45537-1 WC-17338-100512-MW14-MM-251

CLP-1 053(mm)110092012 0029 vr479505d

460-45537-2 WC-17338-100512-MW101-MM-252

CLP-2 053(mm)110092012 0045 vf479506d

460-45537-2 WC-17338-100512-MW101-MM-252

CLP-1 053(mm)110092012 0045 vr479506d

ZZZZZ CLP-2 053(mm)110092012 0100

ZZZZZ CLP-1 053(mm)110092012 0100

ZZZZZ CLP-2 053(mm)110092012 0116

ZZZZZ CLP-1 053(mm)110092012 0116

PIBLK 460-13113718 CLP-2 053(mm)110092012 0131 vf479509d

PIBLK 460-13113718 CLP-1 053(mm)110092012 0131 vr479509d

CCV 460-13113719 CLP-2 053(mm)110092012 0147 vf479510d

CCV 460-13113719 CLP-1 053(mm)110092012 0147 vr479510d

8082

10162012Page 315 of 323

10162012Page 316 of 323

10162012Page 317 of 323

10162012Page 318 of 323

10162012Page 319 of 323

Lab Name Job No

SDG No

GC SEMI VOA BATCH WORKSHEET

460-45537-1

Batch Number Batch AnalystBatch Start Date

Batch End Date

Wu Huachi

100812 1800

100812 0754130997

Batch Method

TestAmerica Edison

3510C

Lab Sample ID Client Sample ID Method Chain Basis ReceivedpH InitialAmount FinalAmount OP_PCBSP 00024 OPPSTPCBSU 00021

AnalysisComment

7 1000 mL 5 mL 50 uL Acid Cleaning_UP

MB 460-1309971 3510C 8082

7 1000 mL 5 mL 50 uL 50 uL Acid Cleaning_UP

LCS 460-1309972

3510C 8082

7 1000 mL 5 mL 50 uL 50 uL Acid Cleaning_UP

LCSD 460-1309973

3510C 8082

WC-17338-100512-MW14-MM-251

7 980 mL 5 mL 50 uL Acid Cleaning_UP

460-45537-E-1 3510C 8082 T

WC-17338-100512-MW101-MM-252

7 990 mL 5 mL 50 uL Acid Cleaning_UP

460-45537-E-2 3510C 8082 T

Batch Notes

Batch Comment 8082Acid Cleaning_up Lot 20042

Persons name who did the concentration Wuh

Exchange Solvent Lot 6383

Exchange Solvent Name Hexane

Final Concentrator Volume 5 mL

N-evap temperature 35 Degrees C

Na2SO4 Lot Number 213204

Prep Solvent Lot 14764

Prep Solvent Name Mecl2

Prep Solvent Volume Used 180 ml mL

Persons name who did the prep Wuh

Persons name who witnessed reagent drop HCP

Basis Basis Description

T TotalNA

Page 1 of 18082

10162012Page 320 of 323

Shipping and

Receiving

Documents

10162012Page 321 of 323

10162012Page 322 of 323

Login Sample Receipt Checklist

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Login Number 45537

Question Answer Comment

Creator Hall Alonzo

List Source TestAmerica Edison

List Number 1

NARadioactivity wasnt checked or is lt= background as measured by a survey

meter

NAThe coolers custody seal if present is intact Not present

TrueSample custody seals if present are intact

TrueThe cooler or samples do not appear to have been compromised or

tampered with

TrueSamples were received on ice

TrueCooler Temperature is acceptable

TrueCooler Temperature is recorded 32deg C IR 2

TrueCOC is present

TrueCOC is filled out in ink and legible

TrueCOC is filled out with all pertinent information

TrueIs the Field Samplers name present on COC

TrueThere are no discrepancies between the containers received and the COC

TrueSamples are received within Holding Time

TrueSample containers have legible labels

TrueContainers are not broken or leaking

TrueSample collection datetimes are provided

TrueAppropriate sample containers are used

TrueSample bottles are completely filled

TrueSample Preservation Verified

TrueThere is sufficient vol for all requested analyses incl any requested

MSMSDs

TrueContainers requiring zero headspace have no headspace or bubble is

lt6mm (14)

NAMultiphasic samples are not present

NASamples do not require splitting or compositing

NAResidual Chlorine Checked No analysis requiring residual chlorine check

assigned

TestAmerica Edison 10162012Page 323 of 323

  • Cover Title Page
  • Table of Contents
  • Data Summaries
    • Report Narrative
    • Sample Summary
    • Executive Summary
    • Method Summary
    • Method Analyst Summary
    • Sample Datasheets
    • Surrogate Summary
    • QC Data Summary
    • Data Qualifiers
    • QC Association Summary
    • Lab Chronicle
      • Organic Sample Data
        • GCMS VOA
          • Method 8260 DEL
            • Method 8260 DEL QC Summary
            • Method 8260 DEL Sample Data
            • Standards Data
              • Method 8260 DEL ICAL Data
              • Method 8260 DEL CCAL Data
                • Raw QC Data
                  • Method 8260 DEL Tune Data
                  • Method 8260 DEL Blank Data
                  • Method 8260 DEL LCSLCSD Data
                  • Method 8260 DEL MSMSD Data
                    • Method 8260 DEL Run Logs
                    • Method 8260 DEL Prep Data
                        • GC Semi VOA
                          • Method 8082 - Delaware
                            • Method 8082 - Delaware QC Summary
                            • Method 8082 - Delaware Sample Data
                            • Standards Data
                              • Method 8082 - Delaware ICAL Data
                              • Method 8082 - Delaware CCAL Data
                                • Raw QC Data
                                  • Method 8082 - Delaware Blank Data
                                  • Method 8082 - Delaware LCSLCSD Data
                                    • Method 8082 - Delaware Run Logs
                                    • Method 8082 - Delaware Prep Data
                                      • Shipping and Receiving Documents
                                        • Client Chain of Custody
                                        • Sample Receipt Checklist
Page 4: J45537-1 Nj Full Package Final Report

CASE NARRATIVE

Client Conestoga-Rovers amp Associates Inc

Project 17338-TO4-2012 RACER GM Wilmington

Report Number 460-45537-1

This case narrative is in the form of an exception report where only the anomalies related to this report method specific performance

andor QAQC issues are discussed If there are no issues to report this narrative will include a statement that documents that there are

no relevant data issues

It should be noted that samples with elevated Reporting Limits (RLs) as a result of a dilution may not be able to satisfy customer reporting

limits in some cases Such increases in the RLs are unavoidable but acceptable consequence of sample dilution that enables

quantification of target analytes or interferences which exceed the calibration range of the instrument

Calculations are performed before rounding to avoid round-off errors in calculated results

All holding times were met and proper preservation noted for the methods performed on these samples unless otherwise detailed in the

individual sections below

RECEIPT

The samples were received on 10052012 710 PM the samples arrived in good condition properly preserved and on ice The

temperature of the coolers at receipt was 32 C

Note All samples which require thermal preservation are considered acceptable if the arrival temperature is within 2C of the required

temperature or method specified range For samples with a specified temperature of 4C samples with a temperature ranging from just

above freezing temperature of water to 6C shall be acceptable Samples that are hand delivered immediately following collection may not

meet these criteria however they will be deemed acceptable according to NELAC standards if there is evidence that the chilling process

has begun such as arrival on ice etc

POLYCHLORINATED BIPHENYLS (PCBS)

Samples 460-45537-1 and 460-45537-2 were analyzed for polychlorinated biphenyls (PCBs) in accordance with EPA SW-846 Method

8082DEL The samples were prepared on 10082012 and analyzed on 10092012

No difficulties were encountered during the PCBs analyses

All quality control parameters were within the acceptance limits

VOLATILE ORGANIC COMPOUNDS (GC-MS)

Samples 460-45537-1 through 460-45537-3 were analyzed for volatile organic compounds (GC-MS) in accordance with EPA SW-846

Method 8260B The samples were analyzed on 10112012 and 10122012

The matrix spike matrix spike duplicate (MSMSD) recoveries for batch 131656 were outside control limits 12-Dibromo-3-chloropropane

The MSD recoveries were also outside control limits for trans-13-Dichloropropene and Methyl tert-butyl ether The associated laboratory

control sample (LCS) recoveries met acceptance criteria

12-Dibromo-3-Chloropropane failed the recovery criteria high for the MS of sample 460-45537-2 in batch 460-131656

12-Dibromo-3-Chloropropane Methyl tert-butyl ether and trans-13-Dichloropropene failed the recovery criteria high for the MSD of

sample 460-45537-2 in batch 460-131656

Refer to the QC report for details

No other difficulties were encountered during the volatiles analyses

All other quality control parameters were within the acceptance limits

10162012Page 4 of 323

SAMPLE SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample IDLab Sample ID Client Matrix Sampled Received

DateTime DateTime

460-45537-1 WC-17338-100512-MW14-MM-2

51

Water 10052012 1000 10052012 1910

460-45537-2 WC-17338-100512-MW101-MM-

252

Water 10052012 1230 10052012 1910

460-45537-3TB TB-17338-100512-253 Water 10052012 0000 10052012 1910

TestAmerica Edison 10162012Page 5 of 323

EXECUTIVE SUMMARY - Detections

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Analyte Result

Reporting

Limit Units Method

Lab Sample ID Client Sample ID

Qualifier

460-45537-1 WC-17338-100512-MW14-MM-251

10 ugL 8260B017 JMethyl tert-butyl ether

10 ugL 8260B017 JToluene

10 ugL 8260B028 JTetrachloroethene

460-45537-2 WC-17338-100512-MW101-MM-252

10 ugL 8260B020 JMethyl tert-butyl ether

460-45537-3TB TB-17338-100512-253

10 ugL 8260B074 JMethylene Chloride

10 ugL 8260B0096 JChloroform

TestAmerica Edison 10162012Page 6 of 323

METHOD SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Preparation MethodMethodLab LocationDescription

Matrix Water

Volatile Organics (GCMS) TAL EDI SW846 8260B

Purge and Trap TAL EDI SW846 5030B

Polychlorinated Biphenyls (PCBs) (GC) TAL EDI SW846 8082

Liquid-Liquid Extraction (Separatory Funnel) TAL EDI SW846 3510C

Lab References

TAL EDI = TestAmerica Edison

Method References

SW846 = Test Methods For Evaluating Solid Waste PhysicalChemical Methods Third Edition November 1986 And Its Updates

TestAmerica Edison 10162012Page 7 of 323

METHOD ANALYST SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Method Analyst Analyst ID

Boykin Kenneth KBSW846 8260B

Boykin Carol B CBBSW846 8082

TestAmerica Edison

10162012Page 8 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

017 J 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

017 J 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

028 J 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 9 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

99 70 - 1304-Bromofluorobenzene

96 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 10 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 11 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

020 J 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 12 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

98 70 - 1304-Bromofluorobenzene

97 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 13 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 14 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

074 J 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

014 U 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0096 J 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 15 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

99 70 - 1304-Bromofluorobenzene

97 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 16 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 17 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0029

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type PRIMARY

980 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

013 U 051013PCB-1016

029 U 051029PCB-1221

012 U 051012PCB-1232

012 U 051012PCB-1242

024 U 051024PCB-1248

017 U 051017PCB-1254

015 U 051015PCB-1260

Surrogate Rec Acceptance LimitsQualifier

83 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 18 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0029

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type SECONDARY

980 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Surrogate Rec Acceptance LimitsQualifier

82 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 19 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0045

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type PRIMARY

990 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

013 U 051013PCB-1016

028 U 051028PCB-1221

012 U 051012PCB-1232

012 U 051012PCB-1242

024 U 051024PCB-1248

017 U 051017PCB-1254

015 U 051015PCB-1260

Surrogate Rec Acceptance LimitsQualifier

52 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 20 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0045

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type SECONDARY

990 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Surrogate Rec Acceptance LimitsQualifier

50 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 21 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Surrogate Recovery Report

8260B Volatile Organics (GCMS)

Client Matrix Water

Lab Sample ID Client Sample ID

DCA TOL BFB

Rec Rec Rec

460-45537-1 WC-17338-100512-M

W14-MM-251

97 96 99

460-45537-2 WC-17338-100512-M

W101-MM-252

97 97 98

460-45537-3 TB-17338-100512-25

3

97 97 99

MB 460-1316564 99 96 95

LCS 460-1316563 96 99 97

460-45537-2 MS WC-17338-100512-M

W101-MM-252 MS

96 99 99

460-45537-2 MSD WC-17338-100512-M

W101-MM-252 MSD

96 99 97

Surrogate Acceptance Limits

DCA = 12-Dichloroethane-d4 (Surr) 70-130

TOL = Toluene-d8 (Surr) 70-130

BFB = 4-Bromofluorobenzene 70-130

TestAmerica Edison

10162012Page 22 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Surrogate Recovery Report

8082 Polychlorinated Biphenyls (PCBs) (GC)

Client Matrix Water

Lab Sample ID Client Sample ID

DCB1 DCB2

Rec Rec

460-45537-1 WC-17338-100512-M

W14-MM-251

82 83

460-45537-2 WC-17338-100512-M

W101-MM-252

52 50

MB 460-1309971-A 97 88

LCS 460-1309972-A 91 84

LCSD

460-1309973-A

108 99

Surrogate Acceptance Limits

DCB = DCB Decachlorobiphenyl 37-150

TestAmerica Edison

10162012Page 23 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-131656

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08981d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5MB 460-1316564

Analysis Date 10112012 2247

Analysis Batch

Prep Batch

Leach Batch

NA

NA

460-131656

Prep Date

Leach Date

10112012 2247

NA

Analyte RLMDLQualResult

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

014 U 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

TestAmerica Edison 10162012Page 24 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-131656

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08981d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5MB 460-1316564

Analysis Date 10112012 2247

Analysis Batch

Prep Batch

Leach Batch

NA

NA

460-131656

Prep Date

Leach Date

10112012 2247

NA

Analyte RLMDLQualResult

014 U 1001413-Dichlorobenzene

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance Limits

12-Dichloroethane-d4 (Surr) 99 70 - 130

4-Bromofluorobenzene 95 70 - 130

Toluene-d8 (Surr) 96 70 - 130

Method Blank TICs- Batch 460-131656

Cas Number Analyte RT Est Result Qual

Tentatively Identified Compound None

TestAmerica Edison 10162012Page 25 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10

Lab Control Sample - Batch 460-131656

Client Matrix

Lab Sample ID

Dilution

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08977d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5LCS 460-1316563

Analysis Date 10112012 2113

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Prep Date

Leach Date

10112012 2113

NA

Analyte QualLimit RecResultSpike Amount

200 210 105 74 - 128111-Trichloroethane

200 181 90 46 - 145Dichlorodifluoromethane

200 210 105 58 - 146Chloromethane

200 203 101 61 - 144Vinyl chloride

200 211 105 55 - 153Bromomethane

200 222 111 70 - 11612-Dibromo-3-Chloropropane

200 209 104 82 - 12212-Dichlorobenzene

200 190 95 69 - 147Trichlorofluoromethane

200 223 112 56 - 13911-Dichloroethene

200 211 106 80 - 12012-Dichloropropane

200 203 102 47 - 139112-Trichloro-122-trifluoroethane

200 250 125 45 - 156Acetone

200 218 109 58 - 139Carbon disulfide

200 220 110 50 - 151Methyl acetate

200 200 100 79 - 119Methylene Chloride

200 216 108 75 - 122trans-12-Dichloroethene

200 217 109 80 - 120Chlorodibromomethane

200 207 104 71 - 115Methyl tert-butyl ether

200 201 101 69 - 145Chloroethane

200 204 102 78 - 12211-Dichloroethane

200 211 106 80 - 120cis-12-Dichloroethene

200 214 107 65 - 1142-Butanone (MEK)

200 205 103 82 - 123Chloroform

200 206 103 79 - 126Ethylbenzene

200 208 104 58 - 133Cyclohexane

200 211 105 73 - 120Carbon tetrachloride

200 212 106 83 - 124Benzene

200 204 102 74 - 11812-Dichloroethane

200 212 106 78 - 119Trichloroethene

200 215 107 61 - 129Methylcyclohexane

200 214 107 79 - 119Dichlorobromomethane

200 216 108 80 - 120cis-13-Dichloropropene

200 214 107 53 - 1204-Methyl-2-pentanone (MIBK)

200 205 103 80 - 120Toluene

200 215 108 78 - 118trans-13-Dichloropropene

200 217 109 79 - 119112-Trichloroethane

200 210 105 68 - 139Tetrachloroethene

200 201 100 53 - 1212-Hexanone

200 215 107 78 - 11812-Dibromoethane

200 206 103 81 - 121Chlorobenzene

600 612 102 76 - 121Xylenes Total

200 207 104 69 - 112Styrene

200 217 109 73 - 123Bromoform

200 207 104 80 - 125Isopropylbenzene

200 210 105 74 - 1261122-Tetrachloroethane

200 204 102 81 - 12613-Dichlorobenzene

TestAmerica Edison 10162012Page 26 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10

Lab Control Sample - Batch 460-131656

Client Matrix

Lab Sample ID

Dilution

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08977d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5LCS 460-1316563

Analysis Date 10112012 2113

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Prep Date

Leach Date

10112012 2113

NA

Analyte QualLimit RecResultSpike Amount

200 204 102 83 - 12314-Dichlorobenzene

200 220 110 66 - 120124-Trichlorobenzene

Surrogate Rec Acceptance Limits

12-Dichloroethane-d4 (Surr) 96 70 - 130

4-Bromofluorobenzene 97 70 - 130

Toluene-d8 (Surr) 99 70 - 130

TestAmerica Edison 10162012Page 27 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Water

50

50

Client Matrix

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Client Matrix Water

e08985d

5 mL

5 mL

e08986d

5 mL

5 mL

Method 8260B

Preparation 5030B

VOAMS5

VOAMS5

460-45537-2

460-45537-2

MS Lab Sample ID

MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

10122012 0051

NA

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

10122012 0027

Analyte RPD LimitRPDLimit

Rec

MS MSD MS Qual MSD Qual

103 106 74 - 128 3 30111-Trichloroethane

87 90 46 - 145 4 30Dichlorodifluoromethane

102 101 58 - 146 0 30Chloromethane

104 105 61 - 144 0 30Vinyl chloride

107 105 55 - 153 2 30Bromomethane

121 121 70 - 116 0 30 F F12-Dibromo-3-Chloropropane

107 111 82 - 122 3 3012-Dichlorobenzene

121 100 69 - 147 19 30Trichlorofluoromethane

108 119 56 - 139 9 3011-Dichloroethene

111 110 80 - 120 0 3012-Dichloropropane

102 111 47 - 139 8 30112-Trichloro-122-trifluoroethane

99 101 45 - 156 2 30Acetone

113 119 58 - 139 5 30Carbon disulfide

100 101 50 - 151 1 30Methyl acetate

106 106 79 - 119 0 30Methylene Chloride

106 108 75 - 122 2 30trans-12-Dichloroethene

116 118 80 - 120 2 30Chlorodibromomethane

114 116 71 - 115 1 30 FMethyl tert-butyl ether

116 105 69 - 145 10 30Chloroethane

104 111 78 - 122 7 3011-Dichloroethane

105 109 80 - 120 4 30cis-12-Dichloroethene

111 114 65 - 114 3 302-Butanone (MEK)

108 113 82 - 123 4 30Chloroform

107 111 79 - 126 3 30Ethylbenzene

108 117 58 - 133 7 30Cyclohexane

105 110 73 - 120 5 30Carbon tetrachloride

106 114 83 - 124 7 30Benzene

107 109 74 - 118 2 3012-Dichloroethane

107 113 78 - 119 5 30Trichloroethene

115 121 61 - 129 5 30Methylcyclohexane

113 116 79 - 119 3 30Dichlorobromomethane

109 115 80 - 120 5 30cis-13-Dichloropropene

111 114 53 - 120 3 304-Methyl-2-pentanone (MIBK)

TestAmerica Edison 10162012Page 28 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Water

50

50

Client Matrix

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Client Matrix Water

e08985d

5 mL

5 mL

e08986d

5 mL

5 mL

Method 8260B

Preparation 5030B

VOAMS5

VOAMS5

460-45537-2

460-45537-2

MS Lab Sample ID

MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

10122012 0051

NA

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

10122012 0027

Analyte RPD LimitRPDLimit

Rec

MS MSD MS Qual MSD Qual

106 111 80 - 120 5 30Toluene

113 119 78 - 118 5 30 Ftrans-13-Dichloropropene

112 116 79 - 119 3 30112-Trichloroethane

110 116 68 - 139 5 30Tetrachloroethene

109 111 53 - 121 2 302-Hexanone

116 117 78 - 118 1 3012-Dibromoethane

107 111 81 - 121 3 30Chlorobenzene

106 110 76 - 121 3 30Xylenes Total

107 110 69 - 112 3 30Styrene

115 114 73 - 123 1 30Bromoform

107 111 80 - 125 4 30Isopropylbenzene

115 116 74 - 126 0 301122-Tetrachloroethane

106 110 81 - 126 4 3013-Dichlorobenzene

106 110 83 - 123 4 3014-Dichlorobenzene

110 119 66 - 120 8 30124-Trichlorobenzene

Surrogate Acceptance LimitsMS Rec MSD Rec

12-Dichloroethane-d4 (Surr) 96 96 70 - 130

4-Bromofluorobenzene 99 97 70 - 130

Toluene-d8 (Surr) 99 99 70 - 130

TestAmerica Edison 10162012Page 29 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10122012 0027 10122012 0051

Dilution Dilution50 50

Client Matrix Client Matrix Water

Method 8260B

Preparation 5030B

Units ugL460-45537-2 460-45537-2MS Lab Sample ID MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

Analysis Date

Prep Date

Leach Date

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

NA

Amount

Sample

Analyte ResultQual Amount ResultQual ResultQual

MS MSDMS Spike MSD Spike

0060 U 100 100 103 106111-Trichloroethane

022 U 100 100 865 896Dichlorodifluoromethane

010 U 100 100 102 101Chloromethane

014 U 100 100 104 105Vinyl chloride

018 U 100 100 107 105Bromomethane

040 U 100 100 121 121F F12-Dibromo-3-Chloropropane

021 U 100 100 107 11112-Dichlorobenzene

015 U 100 100 121 997Trichlorofluoromethane

0090 U 100 100 108 11911-Dichloroethene

0090 U 100 100 111 11012-Dichloropropane

0080 U 100 100 102 111112-Trichloro-122-trifluoroethane

27 U 100 100 986 101Acetone

013 U 100 100 113 119Carbon disulfide

034 U 100 100 100 101Methyl acetate

018 U 100 100 106 106Methylene Chloride

013 U 100 100 106 108trans-12-Dichloroethene

020 U 100 100 116 118Chlorodibromomethane

020 J 100 100 114 116 FMethyl tert-butyl ether

017 U 100 100 116 105Chloroethane

013 U 100 100 104 11111-Dichloroethane

018 U 100 100 105 109cis-12-Dichloroethene

23 U 100 100 111 1142-Butanone (MEK)

0080 U 100 100 108 113Chloroform

010 U 100 100 107 111Ethylbenzene

016 U 100 100 108 117Cyclohexane

0060 U 100 100 105 110Carbon tetrachloride

0080 U 100 100 106 114Benzene

019 U 100 100 107 10912-Dichloroethane

0090 U 100 100 107 113Trichloroethene

014 U 100 100 115 121Methylcyclohexane

012 U 100 100 113 116Dichlorobromomethane

018 U 100 100 109 115cis-13-Dichloropropene

099 U 100 100 111 1144-Methyl-2-pentanone (MIBK)

015 U 100 100 106 111Toluene

024 U 100 100 113 119 Ftrans-13-Dichloropropene

019 U 100 100 112 116112-Trichloroethane

010 U 100 100 110 116Tetrachloroethene

050 U 100 100 109 1112-Hexanone

028 U 100 100 116 11712-Dibromoethane

011 U 100 100 107 111Chlorobenzene

036 U 300 300 318 329Xylenes Total

012 U 100 100 107 110Styrene

019 U 100 100 115 114Bromoform

TestAmerica Edison 10162012Page 30 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10122012 0027 10122012 0051

Dilution Dilution50 50

Client Matrix Client Matrix Water

Method 8260B

Preparation 5030B

Units ugL460-45537-2 460-45537-2MS Lab Sample ID MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

Analysis Date

Prep Date

Leach Date

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

NA

Amount

Sample

Analyte ResultQual Amount ResultQual ResultQual

MS MSDMS Spike MSD Spike

0080 U 100 100 107 111Isopropylbenzene

016 U 100 100 115 1161122-Tetrachloroethane

014 U 100 100 106 11013-Dichlorobenzene

023 U 100 100 106 11014-Dichlorobenzene

034 U 100 100 110 119124-Trichlorobenzene

TestAmerica Edison 10162012Page 31 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-130997

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

vr479496d

1000 mL

5 mLUnits ugL

Method 8082

Preparation 3510C

PESTGC9MB 460-1309971-A

Analysis Date 10082012 2208

Analysis Batch

Prep Batch

Leach Batch NA

460-131137

460-130997

Prep Date Injection Volume

Leach Date

10082012 0755

NA PRIMARYColumn ID

Analyte RLMDLQualResult

013 U 050013PCB-1016

028 U 050028PCB-1221

012 U 050012PCB-1232

012 U 050012PCB-1242

024 U 050024PCB-1248

017 U 050017PCB-1254

015 U 050015PCB-1260

Surrogate Rec Acceptance Limits

DCB Decachlorobiphenyl 97 37 - 150

Surrogate Rec Acceptance Limits

DCB Decachlorobiphenyl 88 37 - 150

TestAmerica Edison 10162012Page 32 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Lab Control Sample

Lab Control Sample Duplicate Recovery Report - Batch 460-130997

10

10

Water

LCS Lab Sample ID

LCSD Lab Sample ID

Client Matrix

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

Client Matrix Water

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

ugL

vf479497d

1000 mL

5 mL

PRIMARY

vf479498d

1000 mL

5 mL

PRIMARY

ugL

Method 8082

Preparation 3510C

PESTGC9

PESTGC9

LCS 460-1309972-A

LCSD 460-1309973-A

Analysis Date

Prep Date

Leach Date

10082012 2224

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

Rec

103101 71 - 126 2 30PCB-1016

119115 73 - 130 4 30PCB-1260

Surrogate LCS Rec LCSD Rec Acceptance Limits

DCB Decachlorobiphenyl 91 108 37 - 150

Dilution

Dilution

Lab Control Sample

Lab Control Sample Duplicate Recovery Report - Batch 460-130997

10

10

Water

LCS Lab Sample ID

LCSD Lab Sample ID

Client Matrix

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

Client Matrix Water

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

ugL

vr479497d

1000 mL

5 mL

SECONDARY

vr479498d

1000 mL

5 mL

SECONDARY

ugL

Method 8082

Preparation 3510C

PESTGC9

PESTGC9

LCS 460-1309972-A

LCSD 460-1309973-A

Analysis Date

Prep Date

Leach Date

10082012 2224

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

Rec

9997 71 - 126 3 30PCB-1016

117111 73 - 130 5 30PCB-1260

Surrogate LCS Rec LCSD Rec Acceptance Limits

DCB Decachlorobiphenyl 84 99 37 - 150

TestAmerica Edison 10162012Page 33 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10082012 2224

Dilution Dilution10 10

Client Matrix

LCSD Lab Sample ID

Client Matrix Water

Laboratory Control

Laboratory Duplicate Data Report - Batch 460-130997

Method 8082

Preparation 3510C

Units ugLLCS 460-1309972-A LCSD 460-1309973-ALCS Lab Sample ID

Analysis Date

Prep Date

Leach Date

10082012 0755

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NANA

LCSD

ResultQual

LCS

ResultQual

LCSD Spike

Amount

LCS Spike

AmountAnalyte

516507500 500PCB-1016

595573500 500PCB-1260

Water

10082012 2224

Dilution Dilution10 10

Client Matrix

LCSD Lab Sample ID

Client Matrix Water

Laboratory Control

Laboratory Duplicate Data Report - Batch 460-130997

Method 8082

Preparation 3510C

Units ugLLCS 460-1309972-A LCSD 460-1309973-ALCS Lab Sample ID

Analysis Date

Prep Date

Leach Date

10082012 0755

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NANA

LCSD

ResultQual

LCS

ResultQual

LCSD Spike

Amount

LCS Spike

AmountAnalyte

497483500 500PCB-1016

583557500 500PCB-1260

TestAmerica Edison 10162012Page 34 of 323

DATA REPORTING QUALIFIERS

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Lab Section Qualifier Description

GCMS VOA

Indicates the analyte was analyzed for but not detectedU

MSMSD Recovery or RPD exceeds the control limitsF

Result is less than the RL but greater than or equal to the MDL and the

concentration is an approximate value

J

GC Semi VOA

Indicates the analyte was analyzed for but not detectedU

TestAmerica Edison 10162012Page 35 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

QC Association Summary

Lab Sample ID Client Sample ID Client Matrix Method Prep Batch

Report

Basis

GCMS VOA

Analysis Batch460-131656

Lab Control Sample Water 8260BLCS 460-1316563 T

Method Blank Water 8260BMB 460-1316564 T

WaterWC-17338-100512-MW14-MM-251 8260B460-45537-1 T

WaterWC-17338-100512-MW101-MM-252 8260B460-45537-2 T

Matrix Spike Water 8260B460-45537-2MS T

Matrix Spike Duplicate Water 8260B460-45537-2MSD T

WaterTB-17338-100512-253 8260B460-45537-3TB T

Report Basis

T = Total

GC Semi VOA

Prep Batch 460-130997

Lab Control Sample Water 3510CLCS 460-1309972-A T

Lab Control Sample Duplicate Water 3510CLCSD 460-1309973-A T

Method Blank Water 3510CMB 460-1309971-A T

WaterWC-17338-100512-MW14-MM-251 3510C460-45537-1 T

WaterWC-17338-100512-MW101-MM-252 3510C460-45537-2 T

Analysis Batch460-131137

Lab Control Sample Water 460-1309978082LCS 460-1309972-A T

Lab Control Sample Duplicate Water 460-1309978082LCSD 460-1309973-A T

Method Blank Water 460-1309978082MB 460-1309971-A T

Water 460-130997WC-17338-100512-MW14-MM-251 8082460-45537-1 T

Water 460-130997WC-17338-100512-MW101-MM-252 8082460-45537-2 T

Report Basis

T = Total

TestAmerica Edison

10162012Page 36 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Laboratory Chronicle

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1000

460-45537-1 WC-17338-100512-MW14-MM-251

P5030B 460-45537-A-1 460-131656 10112012 2341 KBTAL EDI1

A8260B 460-45537-A-1 460-131656 10112012 2341 KBTAL EDI1

P3510C 460-45537-E-1-B 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 460-45537-E-1-B 460-131137 460-130997 10092012 0029 CBBTAL EDI1

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 WC-17338-100512-MW101-MM-252

P5030B 460-45537-A-2 460-131656 10122012 0004 KBTAL EDI1

A8260B 460-45537-A-2 460-131656 10122012 0004 KBTAL EDI1

P3510C 460-45537-E-2-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 460-45537-E-2-A 460-131137 460-130997 10092012 0045 CBBTAL EDI1

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 MS WC-17338-100512-MW101-MM-252

P5030B 460-45537-C-2 MS 460-131656 10122012 0027 KBTAL EDI5

A8260B 460-45537-C-2 MS 460-131656 10122012 0027 KBTAL EDI5

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 MSD WC-17338-100512-MW101-MM-252

P5030B 460-45537-C-2 MSD 460-131656 10122012 0051 KBTAL EDI5

A8260B 460-45537-C-2 MSD 460-131656 10122012 0051 KBTAL EDI5

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 0000

460-45537-3 TB-17338-100512-253

P5030B 460-45537-A-3 460-131656 10112012 2317 KBTAL EDI1

A8260B 460-45537-A-3 460-131656 10112012 2317 KBTAL EDI1

A = Analytical Method P = Prep Method TestAmerica Edison

10162012Page 37 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Laboratory Chronicle

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

MB NA

P5030B MB 460-1316564 460-131656 10112012 2247 KBTAL EDI1

A8260B MB 460-1316564 460-131656 10112012 2247 KBTAL EDI1

P3510C MB 460-1309971-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 MB 460-1309971-A 460-131137 460-130997 10082012 2208 CBBTAL EDI1

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

LCS NA

P5030B LCS 460-1316563 460-131656 10112012 2113 KBTAL EDI1

A8260B LCS 460-1316563 460-131656 10112012 2113 KBTAL EDI1

P3510C LCS 460-1309972-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 LCS 460-1309972-A 460-131137 460-130997 10082012 2224 CBBTAL EDI1

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

LCSD NA

P3510C LCSD

460-1309973-A

460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 LCSD

460-1309973-A

460-131137 460-130997 10082012 2239 CBBTAL EDI1

Lab ReferencesTAL EDI = TestAmerica Edison

A = Analytical Method P = Prep Method TestAmerica Edison

10162012Page 38 of 323

Method 8260 DELVolatile Organics (GCMS) by Method

8260 (Delaware)

10162012Page 39 of 323

FORM II

GCMS VOA SURROGATE RECOVERY

Lab Name Job No 460-45537-1

SDG No

Matrix Water Level Low

TestAmerica Edison

GC Column (1) Rtx-VMS ID 018(mm)

Lab Sample IDClient Sample ID DCA TOL BFB

460-45537-1WC-17338-100512-MW14-MM-251

97 96 99

460-45537-2WC-17338-100512-MW101-MM-252

97 97 98

460-45537-3TB-17338-100512-253

97 97 99

MB 460-1316564 99 96 95

LCS 460-1316563 96 99 97

460-45537-2 MSWC-17338-100512-MW101-MM-252 MS

96 99 99

460-45537-2 MSDWC-17338-100512-MW101-MM-252 MSD

96 99 97

QC LIMITSQC LIMITSDCA = 12-Dichloroethane-d4 (Surr) 70-130

TOL = Toluene-d8 (Surr) 70-130

BFB = 4-Bromofluorobenzene 70-130

FORM II 8260B

Column to be used to flag recovery values

10162012Page 40 of 323

GCMS VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08977dWater

Lab ID LCS 460-1316563 Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

111-Trichloroethane 200 210 74-128105

Dichlorodifluoromethane 200 181 46-14590

Chloromethane 200 210 58-146105

Vinyl chloride 200 203 61-144101

Bromomethane 200 211 55-153105

12-Dibromo-3-Chloropropane 200 222 70-116111

12-Dichlorobenzene 200 209 82-122104

Trichlorofluoromethane 200 190 69-14795

11-Dichloroethene 200 223 56-139112

12-Dichloropropane 200 211 80-120106

112-Trichloro-122-trifluoroethane

200 203 47-139102

Acetone 200 250 45-156125

Carbon disulfide 200 218 58-139109

Methyl acetate 200 220 50-151110

Methylene Chloride 200 200 79-119100

trans-12-Dichloroethene 200 216 75-122108

Chlorodibromomethane 200 217 80-120109

Methyl tert-butyl ether 200 207 71-115104

Chloroethane 200 201 69-145101

11-Dichloroethane 200 204 78-122102

cis-12-Dichloroethene 200 211 80-120106

2-Butanone (MEK) 200 214 65-114107

Chloroform 200 205 82-123103

Ethylbenzene 200 206 79-126103

Cyclohexane 200 208 58-133104

Carbon tetrachloride 200 211 73-120105

Benzene 200 212 83-124106

12-Dichloroethane 200 204 74-118102

Trichloroethene 200 212 78-119106

Methylcyclohexane 200 215 61-129107

Dichlorobromomethane 200 214 79-119107

cis-13-Dichloropropene 200 216 80-120108

4-Methyl-2-pentanone (MIBK) 200 214 53-120107

Toluene 200 205 80-120103

trans-13-Dichloropropene 200 215 78-118108

112-Trichloroethane 200 217 79-119109

Tetrachloroethene 200 210 68-139105

2-Hexanone 200 201 53-121100

12-Dibromoethane 200 215 78-118107

Chlorobenzene 200 206 81-121103

Xylenes Total 600 612 76-121102

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 41 of 323

GCMS VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08977dWater

Lab ID LCS 460-1316563 Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

Styrene 200 207 69-112104

Bromoform 200 217 73-123109

Isopropylbenzene 200 207 80-125104

1122-Tetrachloroethane 200 210 74-126105

13-Dichlorobenzene 200 204 81-126102

14-Dichlorobenzene 200 204 83-123102

124-Trichlorobenzene 200 220 66-120110

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 42 of 323

GCMS VOA MATRIX SPIKE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08985dWater

Lab ID 460-45537-2 MS Client ID WC-17338-100512-MW101-MM-252 MS

TestAmerica Edison

LIMITS

COMPOUND

CONCENTRATION

REC

QC

REC

SAMPLE

CONCENTRATION

SPIKE

ADDED

(ugL) (ugL) (ugL)

MS MS

100 103 74-128111-Trichloroethane 1030060 U

100 865 46-145Dichlorodifluoromethane 87022 U

100 102 58-146Chloromethane 102010 U

100 104 61-144Vinyl chloride 104014 U

100 107 55-153Bromomethane 107018 U

100 121 70-11612-Dibromo-3-Chloropropane 121040 U F

100 107 82-12212-Dichlorobenzene 107021 U

100 121 69-147Trichlorofluoromethane 121015 U

100 108 56-13911-Dichloroethene 1080090 U

100 111 80-12012-Dichloropropane 1110090 U

100 102 47-139112-Trichloro-122-trifluoroethane

1020080 U

100 986 45-156Acetone 9927 U

100 113 58-139Carbon disulfide 113013 U

100 100 50-151Methyl acetate 100034 U

100 106 79-119Methylene Chloride 106018 U

100 106 75-122trans-12-Dichloroethene 106013 U

100 116 80-120Chlorodibromomethane 116020 U

100 114 71-115Methyl tert-butyl ether 114020 J

100 116 69-145Chloroethane 116017 U

100 104 78-12211-Dichloroethane 104013 U

100 105 80-120cis-12-Dichloroethene 105018 U

100 111 65-1142-Butanone (MEK) 11123 U

100 108 82-123Chloroform 1080080 U

100 107 79-126Ethylbenzene 107010 U

100 108 58-133Cyclohexane 108016 U

100 105 73-120Carbon tetrachloride 1050060 U

100 106 83-124Benzene 1060080 U

100 107 74-11812-Dichloroethane 107019 U

100 107 78-119Trichloroethene 1070090 U

100 115 61-129Methylcyclohexane 115014 U

100 113 79-119Dichlorobromomethane 113012 U

100 109 80-120cis-13-Dichloropropene 109018 U

100 111 53-1204-Methyl-2-pentanone (MIBK) 111099 U

100 106 80-120Toluene 106015 U

100 113 78-118trans-13-Dichloropropene 113024 U

100 112 79-119112-Trichloroethane 112019 U

100 110 68-139Tetrachloroethene 110010 U

100 109 53-1212-Hexanone 109050 U

100 116 78-11812-Dibromoethane 116028 U

100 107 81-121Chlorobenzene 107011 U

300 318 76-121Xylenes Total 106036 U

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 43 of 323

GCMS VOA MATRIX SPIKE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08985dWater

Lab ID 460-45537-2 MS Client ID WC-17338-100512-MW101-MM-252 MS

TestAmerica Edison

LIMITS

COMPOUND

CONCENTRATION

REC

QC

REC

SAMPLE

CONCENTRATION

SPIKE

ADDED

(ugL) (ugL) (ugL)

MS MS

100 107 69-112Styrene 107012 U

100 115 73-123Bromoform 115019 U

100 107 80-125Isopropylbenzene 1070080 U

100 115 74-1261122-Tetrachloroethane 115016 U

100 106 81-12613-Dichlorobenzene 106014 U

100 106 83-12314-Dichlorobenzene 106023 U

100 110 66-120124-Trichlorobenzene 110034 U

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 44 of 323

GCMS VOA MATRIX SPIKE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08986dWater

Lab ID 460-45537-2 MSD Client ID WC-17338-100512-MW101-MM-252

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

MSD MSD

100 106 30 74-128111-Trichloroethane 3106

100 896 30 46-145Dichlorodifluoromethane 490

100 101 30 58-146Chloromethane 0101

100 105 30 61-144Vinyl chloride 0105

100 105 30 55-153Bromomethane 2105

100 121 30 70-11612-Dibromo-3-Chloropropane 0121 F

100 111 30 82-12212-Dichlorobenzene 3111

100 997 30 69-147Trichlorofluoromethane 19100

100 119 30 56-13911-Dichloroethene 9119

100 110 30 80-12012-Dichloropropane 0110

100 111 30 47-139112-Trichloro-122-trifluoroethane

8111

100 101 30 45-156Acetone 2101

100 119 30 58-139Carbon disulfide 5119

100 101 30 50-151Methyl acetate 1101

100 106 30 79-119Methylene Chloride 0106

100 108 30 75-122trans-12-Dichloroethene 2108

100 118 30 80-120Chlorodibromomethane 2118

100 116 30 71-115Methyl tert-butyl ether 1116 F

100 105 30 69-145Chloroethane 10105

100 111 30 78-12211-Dichloroethane 7111

100 109 30 80-120cis-12-Dichloroethene 4109

100 114 30 65-1142-Butanone (MEK) 3114

100 113 30 82-123Chloroform 4113

100 111 30 79-126Ethylbenzene 3111

100 117 30 58-133Cyclohexane 7117

100 110 30 73-120Carbon tetrachloride 5110

100 114 30 83-124Benzene 7114

100 109 30 74-11812-Dichloroethane 2109

100 113 30 78-119Trichloroethene 5113

100 121 30 61-129Methylcyclohexane 5121

100 116 30 79-119Dichlorobromomethane 3116

100 115 30 80-120cis-13-Dichloropropene 5115

100 114 30 53-1204-Methyl-2-pentanone (MIBK) 3114

100 111 30 80-120Toluene 5111

100 119 30 78-118trans-13-Dichloropropene 5119 F

100 116 30 79-119112-Trichloroethane 3116

100 116 30 68-139Tetrachloroethene 5116

100 111 30 53-1212-Hexanone 2111

100 117 30 78-11812-Dibromoethane 1117

100 111 30 81-121Chlorobenzene 3111

300 329 30 76-121Xylenes Total 3110

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 45 of 323

GCMS VOA MATRIX SPIKE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08986dWater

Lab ID 460-45537-2 MSD Client ID WC-17338-100512-MW101-MM-252

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

MSD MSD

100 110 30 69-112Styrene 3110

100 114 30 73-123Bromoform 1114

100 111 30 80-125Isopropylbenzene 4111

100 116 30 74-1261122-Tetrachloroethane 0116

100 110 30 81-12613-Dichlorobenzene 4110

100 110 30 83-12314-Dichlorobenzene 4110

100 119 30 66-120124-Trichlorobenzene 8119

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 46 of 323

FORM IV

GCMS VOA METHOD BLANK SUMMARY

Lab Name

SDG No

Job No 460-45537-1TestAmerica Edison

Date Analyzed

GC Column ID

Instrument ID 10112012 2247

Rtx-VMS

NHeated Purge(YN)

VOAMS5

e08981dLab File ID Lab Sample ID MB 460-1316564

WaterMatrix

018(mm)

THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES

LAB SAMPLE ID

LAB

FILE ID DATE ANALYZEDCLIENT SAMPLE ID

10112012 2113e08977dLCS 460-1316563

10112012 2317e08982d460-45537-3TB-17338-100512-253

10112012 2341e08983d460-45537-1WC-17338-100512-MW14-MM-251

10122012 0004e08984d460-45537-2WC-17338-100512-MW101-MM-252

10122012 0027e08985d460-45537-2 MSWC-17338-100512-MW101-MM-252 MS

10122012 0051e08986d460-45537-2 MSDWC-17338-100512-MW101-MM-252 MSD

FORM IV 8260B

10162012Page 47 of 323

FORM V

BROMOFLUOROBENZENE (BFB)

Lab Name

SDG No

Job No 460-45537-1

Lab File ID

Instrument ID

e07834d

VOAMS5

09172012

0324

BFB Injection Date

BFB Injection Time

ME ION ABUNDANCE CRITERIA RELATIVEABUNDANCE

Analysis Batch No 128076

50 150 - 400 of mass 95 219

75 300 - 600 of mass 95 525

95 Base Peak 100 relative abundance 1000

96 50 - 90 of mass 95 64

173 Less than 20 of mass 174 00 (00)1

174 500 - 12000 of mass 95 796

175 50 - 90 of mass 174 66 (83)1

176 950 - 1010 of mass 174 761 (957)1

177 50 - 90 of mass 176 48 (63)2

1-Value is mass 174 2-Value is mass 176

THIS CHECK APPLIES TO THE FOLLOWING SAMPLES MS MSD BLANKS AND STANDARDS

GCMS VOA INSTRUMENT PERFORMANCE CHECK

TestAmerica Edison

CLIENT SAMPLE IDLAB

FILE IDLAB SAMPLE IDDATE

ANALYZEDTIME

ANALYZED

e07836d 09172012 0449IC 460-1280762

e07838d 09172012 0536IC 460-1280763

e07839d 09172012 0600ICIS 460-1280764

e07840d 09172012 0623IC 460-1280765

e07841d 09172012 0646IC 460-1280766

e07842d 09172012 0710IC 460-1280767

FORM V 8260B 10162012Page 48 of 323

FORM V

BROMOFLUOROBENZENE (BFB)

Lab Name

SDG No

Job No 460-45537-1

Lab File ID

Instrument ID

e08975d

VOAMS5

10112012

2008

BFB Injection Date

BFB Injection Time

ME ION ABUNDANCE CRITERIA RELATIVEABUNDANCE

Analysis Batch No 131656

50 150 - 400 of mass 95 218

75 300 - 600 of mass 95 518

95 Base Peak 100 relative abundance 1000

96 50 - 90 of mass 95 65

173 Less than 20 of mass 174 07 (07)1

174 500 - 12000 of mass 95 896

175 50 - 90 of mass 174 72 (80)1

176 950 - 1010 of mass 174 872 (973)1

177 50 - 90 of mass 176 53 (61)2

1-Value is mass 174 2-Value is mass 176

THIS CHECK APPLIES TO THE FOLLOWING SAMPLES MS MSD BLANKS AND STANDARDS

GCMS VOA INSTRUMENT PERFORMANCE CHECK

TestAmerica Edison

CLIENT SAMPLE IDLAB

FILE IDLAB SAMPLE IDDATE

ANALYZEDTIME

ANALYZED

e08976d 10112012 2050CCVIS 460-1316562

e08977d 10112012 2113LCS 460-1316563

e08981d 10112012 2247MB 460-1316564

TB-17338-100512-253 e08982d 10112012 2317460-45537-3

WC-17338-100512-MW14-MM-251

e08983d 10112012 2341460-45537-1

WC-17338-100512-MW101-MM-252

e08984d 10122012 0004460-45537-2

WC-17338-100512-MW101-MM-252 MS

e08985d 10122012 0027460-45537-2 MS

WC-17338-100512-MW101-MM-252 MSD

e08986d 10122012 0051460-45537-2 MSD

e08987d 10122012 0114CCV 460-13165610

FORM V 8260B 10162012Page 49 of 323

GCMS VOA INTERNAL STANDARD AREA AND RETENTION TIME SUMMARY

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVIS 460-1316562 Date Analyzed 10112012 2050

Lab File ID (Standard) e08976d

Instrument ID VOAMS5 GC Column Rtx-VMS ID 018(mm)

Heated Purge (YN) N

Calibration ID 17515

AREA RT AREA RT AREA RT

FB CBZ DCB

UPPER LIMIT

LOWER LIMIT

2625312

656328 578671

2314682

333917

1335668

360 695 10471224 HOUR STD

410

310

745

645

1097

997

1312656 1157341 667834

LAB SAMPLE ID CLIENT SAMPLE ID

LCS 460-1316563 1318918 1146590 683882 360 695 1047

MB 460-1316564 1238441 1084553 638826 360 695 1047

460-45537-3 TB-17338-100512-253 1280000 1135339 646856 359 695 1047

460-45537-1 WC-17338-100512-MW14-MM-251

1242225 1119807 641810 359 695 1047

460-45537-2 WC-17338-100512-MW101-MM-252

1247617 1105330 633816 360 695 1047

460-45537-2 MS WC-17338-100512-MW101-MM-252 MS

1234975 1102789 642491 359 695 1047

460-45537-2 MSD WC-17338-100512-MW101-MM-252 MSD

1296388 1119645 654839 360 695 1047

CCV 460-13165610 1274024 1125053 665092 359 695 1047

FB = Fluorobenzene

CBZ = Chlorobenzene-d5

DCB = 14-Dichlorobenzene-d4

Area Limit = 50-200 of internal standard area

RT Limit = plusmn 05 minutes of internal standard RT

Column used to flag values outside QC limits

FORM VIII 8260B

10162012Page 50 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014J1634-04-4 Methyl tert-butyl ether 017

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015J108-88-3 Toluene 017

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 51 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010J127-18-4 Tetrachloroethene 028

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

96 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 52 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 53 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08983d Report Date 12-Oct-2012 0041

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08983dLab Smp Id 460-45537-A-1 Client Smp ID WC-17338-100512-MW1Inj Date 11-OCT-2012 2341 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-1Misc Info 460-45537-A-1Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 8 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

28 MTBE 73 2016 2022 (0561) 2797 016909 017(a)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 375883 486598 49

52 Fluorobenzene 96 3595 3601 (1000) 1242225 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1240232 479413 48

66 Toluene 91 5162 5162 (0742) 4639 017041 017(a)

71 Tetrachloroethene 166 5582 5582 (0803) 1902 028047 028(a)

78 Chlorobenzene-d5 117 6954 6954 (1000) 1119807 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 516081 495668 50

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 641810 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 54 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

10162012Page 55 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

28 MTBE

10162012Page 56 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

66 Toluene

10162012Page 57 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

71 Tetrachloroethene

10162012Page 58 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014J1634-04-4 Methyl tert-butyl ether 020

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 59 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

98 70-130460-00-4 4-Bromofluorobenzene

97 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 60 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 61 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08984d Report Date 12-Oct-2012 1126

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08984dLab Smp Id 460-45537-A-2 Client Smp ID WC-17338-100512-MW1Inj Date 12-OCT-2012 0004 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-2Misc Info 460-45537-A-2Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 9 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

28 MTBE 73 2016 2022 (0561) 3378 020333 020(a)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 375158 483561 48

52 Fluorobenzene 96 3595 3601 (1000) 1247617 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1243750 487069 49

78 Chlorobenzene-d5 117 6954 6954 (1000) 1105330 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 506189 492299 49

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 633816 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 62 of 323

Data File e08984d

Date 12-OCT-2012 0004

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-2 Operator GCMS VOAMS5

10162012Page 63 of 323

Data File e08984d

Date 12-OCT-2012 0004

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-2 Operator GCMS VOAMS5

28 MTBE

10162012Page 64 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018J75-09-2 Methylene Chloride 074

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014U1634-04-4 Methyl tert-butyl ether 014

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080J67-66-3 Chloroform 0096

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 65 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

97 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 66 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 67 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08982d Report Date 12-Oct-2012 1126

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08982dLab Smp Id 460-45537-A-3 Client Smp ID TB-17338-100512-253Inj Date 11-OCT-2012 2317 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-3Misc Info 460-45537-A-3Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 7 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

22 Methylene Chloride 49 1864 1864 (0518) 6426 073512 074(a)

42 Chloroform 83 2839 2845 (0790) 973 009557 0096(aH)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 385354 484137 48

52 Fluorobenzene 96 3595 3601 (1000) 1280000 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1266759 482968 48

78 Chlorobenzene-d5 117 6954 6954 (1000) 1135339 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 518232 493851 49

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 646856 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

H - Operator selected an alternate compound hit

10162012Page 68 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

10162012Page 69 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

22 Methylene Chloride

10162012Page 70 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

42 Chloroform

10162012Page 71 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1280762 e07836d2Level IC 460-1280763 e07838d3Level ICIS 460-1280764 e07839d4Level IC 460-1280765 e07840d5Level IC 460-1280766 e07841d6Level IC 460-1280767 e07842d

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

Dichlorodifluoromethane 01877 01710 01761 01874 01774 Ave 6501572

01000 30001761

Chloromethane 04585 03624 03717 03896 03503 Ave 13403074

01000 30003733

Vinyl chloride 03440 02904 02965 03157 02914 Ave 10102532

01000 30002985

Bromomethane 01457 01433 01250 01279 01268 Ave 8301184

01000 30001312

Chloroethane 01177 01273 01133 01184 00992 Ave 14300838

01000 30001099

Trichlorofluoromethane 02861 02160 02403 02359 02461 Ave 9902285

01000 30002422

11-Dichloroethene 01607 01355 01549 01479 01528 Ave 5801456

01000 30001496

Carbon disulfide 07031 06470 06825 07347 07283 Ave 5906366

01000 30006887

112-Trichloro-122-trifluoroethane 01346 01631 01661 01849 01887 Ave 11601772

01000 30001691

Methylene Chloride 04479 03769 03581 03500 03182 Ave 14802947

01000 30003576

Acetone 00225 00193 00188 00182 00162 Ave 13800153

01000 30000184

trans-12-Dichloroethene 02047 01989 02141 02174 02016 Ave 4301946

01000 30002052

Methyl acetate 00482 00463 00420 00421 00402 Ave 9400371

01000 30000426

Methyl tert-butyl ether 07109 07281 06924 06817 06907 Ave 6505992

01000 30006838

11-Dichloroethane 04650 04524 04893 04673 04494 Ave 4604257

01000 30004582

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 72 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

cis-12-Dichloroethene 02536 02396 02453 02363 02237 Ave 5602184

01000 30002361

Cyclohexane 03116 04199 04030 04447 04640 Ave 13204438

01000 30004145

Chloroform 03895 04109 04030 04060 03948 Ave 2503851

01000 30003982

Carbon tetrachloride 02420 02373 02793 02813 02930 Ave 9102903

01000 30002705

111-Trichloroethane 03091 03114 03513 03424 03583 Ave 6403522

01000 30003375

2-Butanone (MEK) 00273 00279 00385 00372 00372 Ave 14900364

01000 30000341

Benzene 12012 12533 12592 12117 12284 Ave 8709836

01000 30011896

12-Dichloroethane 03398 03425 03293 03270 03193 Ave 3503124

01000 30003284

Methylcyclohexane 02272 03440 03287 03727 03690 Ave 16303532

01000 30003325

Trichloroethene 02571 02192 02414 02341 02365 Ave 5202426

01000 30002385

12-Dichloropropane 02758 02786 02804 02730 02724 Ave 1202733

01000 30002756

Dichlorobromomethane 03209 03160 03185 03141 03239 Ave 1303237

01000 30003195

cis-13-Dichloropropene 05043 05293 05370 05217 05393 Ave 3105530

01000 30005308

Toluene 13662 13454 14250 13844 13425 Ave 9510731

01000 30013228

Tetrachloroethene 02730 02844 03369 03253 03225 Ave 8303255

01000 30003113

4-Methyl-2-pentanone (MIBK) 03587 03603 03526 03550 03603 Ave 1603692

01000 30003593

trans-13-Dichloropropene 04563 04743 04806 04779 04910 Ave 3805114

01000 30004819

112-Trichloroethane 02303 02327 02287 02201 02185 Ave 2502280

01000 30002264

Chlorodibromomethane 03013 02986 03088 03052 03111 Ave 3003249

01000 30003083

12-Dibromoethane 02596 02708 02743 02671 02629 Ave 2002676

01000 30002670

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 73 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

2-Hexanone 02652 02737 02670 02679 02755 Ave 3202514

01000 30002668

Chlorobenzene 08958 08985 09292 09070 08727 Ave 4008261

01000 30008882

Ethylbenzene 04549 04523 04953 04866 04834 Ave 3704808

01000 30004756

m-Xylene amp p-Xylene 05967 05752 06297 06168 06094 Ave 6505224

01000 30005917

o-Xylene 05732 05675 06142 06014 05989 Ave 3205765

01000 30005886

Bromoform 02053 01991 02150 02194 02258 Ave 4902237

01000 30002147

Styrene 09657 09899 10525 10511 10477 Ave 6408917

01000 30009998

Isopropylbenzene 13314 13509 15606 15346 15340 Ave 10811764

01000 30014146

1122-Tetrachloroethane 06545 06405 06616 06489 06390 Ave 1706330

01000 30006462

13-Dichlorobenzene 12616 12687 13292 13133 12758 Ave 3012242

01000 30012788

14-Dichlorobenzene 13636 13114 13708 13534 13010 Ave 3412550

01000 30013259

12-Dichlorobenzene 12298 12143 12601 12232 11746 Ave 3211521

01000 30012090

12-Dibromo-3-Chloropropane 01290 01163 01082 01109 01042 Ave 7801095

01000 30001130

124-Trichlorobenzene 06538 06139 06311 06265 05725 Ave 5405732

01000 30006118

12-Dichloroethane-d4 (Surr) 02599 02736 02573 02553 02667 Ave 2802702

01000 30002638

Toluene-d8 (Surr) 11377 12027 11720 11573 11645 Ave 1811690

01000 30011672

4-Bromofluorobenzene 07799 08146 08086 08044 08193 Ave 1908206

01000 30008079

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 74 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1280762 e07836dLevel 2 IC 460-1280763 e07838dLevel 3 ICIS 460-1280764 e07839dLevel 4 IC 460-1280765 e07840dLevel 5 IC 460-1280766 e07841dLevel 6 IC 460-1280767 e07842d

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Dichlorodifluoromethane AveFB 8660 39416 167418 450014 17982634551928

100 500 200 500 200500

Chloromethane AveFB 21155 83523 353287 935453 35519068902969

100 500 200 500 200500

Vinyl chloride AveFB 15876 66919 281874 757876 29543837332518

100 500 200 500 200500

Bromomethane AveFB 6723 33032 118799 307121 12855673429373

100 500 200 500 200500

Chloroethane AveFB 5433 29332 107678 284219 10059762426216

100 500 200 500 200500

Trichlorofluoromethane AveFB 13203 49780 228376 566305 24953266618134

100 500 200 500 200500

11-Dichloroethene AveFB 7415 31234 147259 355088 15491024214942

100 500 200 500 200500

Carbon disulfide AveFB 32446 149121 648801 1763903 738404918433408

100 500 200 500 200500

112-Trichloro-122-trifluoroethane

AveFB 6213 37580 157867 443949 19130255130629

100 500 200 500 200500

Methylene Chloride AveFB 20667 86862 340378 840419 32256318533685

100 500 200 500 200500

Acetone AveFB 5188 13342 17849 43750 164598441742

500 150 200 500 200500

trans-12-Dichloroethene AveFB 9445 45844 203500 521911 20443355633771

100 500 200 500 200500

Methyl acetate AveFB 2222 10660 39926 101112 4077131074355

100 500 200 500 200500

Methyl tert-butyl ether AveFB 32806 167790 658123 1636664 700252217351574

100 500 200 500 200500

11-Dichloroethane AveFB 21457 104265 465144 1121930 455634112326764

100 500 200 500 200500

cis-12-Dichloroethene AveFB 11702 55218 233129 567238 22679686324299

100 500 200 500 200500

FORM VI 8260B 10162012Page 75 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Cyclohexane AveFB 14380 96765 383104 1067735 470410312852489

100 500 200 500 200500

Chloroform AveFB 17974 94697 383084 974788 400250611152231

100 500 200 500 200500

Carbon tetrachloride AveFB 11168 54679 265527 675330 29705928405131

100 500 200 500 200500

111-Trichloroethane AveFB 14264 71766 333961 821993 363312510199723

100 500 200 500 200500

2-Butanone (MEK) AveFB 6291 19260 36552 89217 3773171055008

500 150 200 500 200500

Benzene AveCBZ 45050 227079 968083 2380099 986355721876514

100 500 200 500 200500

12-Dichloroethane AveFB 15679 78926 312991 785178 32368389046377

100 500 200 500 200500

Methylcyclohexane AveFB 10486 79279 312424 894738 374094710227785

100 500 200 500 200500

Trichloroethene AveFB 11865 50527 229465 562086 23978387026524

100 500 200 500 200500

12-Dichloropropane AveFB 12728 64209 266559 655380 27621167913672

100 500 200 500 200500

Dichlorobromomethane AveFB 14807 72835 302742 754124 32836079374106

100 500 200 500 200500

cis-13-Dichloropropene AveCBZ 18914 95905 412847 1024782 433022112299317

100 500 200 500 200500

Toluene AveCBZ 51238 243768 1095520 2719268 1077972123868197

100 500 200 500 200500

Tetrachloroethene AveCBZ 10238 51530 258990 639002 25895417239654

100 500 200 500 200500

4-Methyl-2-pentanone (MIBK) AveCBZ 67258 195851 271059 697282 28927468212153

500 150 200 500 200500

trans-13-Dichloropropene AveCBZ 17115 85943 369516 938808 394242511373599

100 500 200 500 200500

112-Trichloroethane AveCBZ 8636 42154 175853 432262 17543015071317

100 500 200 500 200500

Chlorodibromomethane AveCBZ 11301 54107 237421 599464 24982697227226

100 500 200 500 200500

12-Dibromoethane AveCBZ 9735 49066 210900 524614 21107665952425

100 500 200 500 200500

2-Hexanone AveCBZ 49729 148758 205286 526223 22117155590902

500 150 200 500 200500

Chlorobenzene AveCBZ 33596 162793 714336 1781568 700752018374405

100 500 200 500 200500

FORM VI 8260B 10162012Page 76 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Ethylbenzene AveCBZ 17061 81955 380762 955894 388164310693410

100 500 200 500 200500

m-Xylene amp p-Xylene AveCBZ 44761 208423 968280 2423002 978688223238078

200 100 400 100 4001000

o-Xylene AveCBZ 21499 102832 472158 1181273 480921512821590

100 500 200 500 200500

Bromoform AveCBZ 7698 36074 165267 430943 18127954974461

100 500 200 500 200500

Styrene AveCBZ 36217 179367 809158 2064560 841264519831782

100 500 200 500 200500

Isopropylbenzene AveCBZ 49933 244766 1199765 3014281 1231710326165908

100 500 200 500 200500

1122-Tetrachloroethane AveDCB 13823 63947 277413 702309 28987687365342

100 500 200 500 200500

13-Dichlorobenzene AveDCB 26644 126663 557342 1421450 578731414243841

100 500 200 500 200500

14-Dichlorobenzene AveDCB 28798 130929 574816 1464915 590189114602396

100 500 200 500 200500

12-Dichlorobenzene AveDCB 25972 121236 528396 1324016 532862113405399

100 500 200 500 200500

12-Dibromo-3-Chloropropane AveDCB 2725 11615 45388 120062 4727441274610

100 500 200 500 200500

124-Trichlorobenzene AveDCB 13808 61295 264648 678119 25969596669727

100 500 200 500 200500

12-Dichloroethane-d4 (Surr) AveFB 599539 630441 611357 613057 676105782507

500 500 500 500 500500

Toluene-d8 (Surr) AveCBZ 2133452 2179204 2252606 2273339 23375152600040

500 500 500 500 500500

4-Bromofluorobenzene AveDCB 823604 813301 847619 870646 929176954872

500 500 500 500 500500

Curve Type LegendAve = Average ISTD

FORM VI 8260B 10162012Page 77 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07836d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07836dLab Smp Id IC-VMCAL1 Inj Date 17-SEP-2012 0449 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL1Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 2 Calibration Sample Level 1Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 8660 100000 11

3 Chloromethane 50 1004 1004 (0280) 21155 100000 12

4 Vinyl Chloride 62 1016 1016 (0283) 15876 100000 12

6 Bromomethane 94 1169 1169 (0326) 6723 100000 11

5 Chloroethane 64 1230 1230 (0343) 5433 100000 11

7 Trichlorofluoromethane 101 1291 1291 (0360) 13203 100000 12

14 Freon TF 101 1565 1565 (0436) 6213 100000 080(a)

15 11-Dichloroethene 96 1547 1547 (0431) 7415 100000 11

16 Acetone 58 1882 1882 (0524) 5188 500000 61

18 Carbon Disulfide 76 1559 1559 (0434) 32446 100000 10

27 Methyl Acetate 74 1955 1955 (0545) 2222 100000 11

22 Methylene Chloride 49 1851 1851 (0516) 20667 100000 12

28 MTBE 73 2016 2016 (0562) 32806 100000 10

25 trans-12-Dichloroethene 96 1937 1937 (0540) 9445 100000 100

30 11-Dichloroethane 63 2303 2303 (0642) 21457 100000 10

36 cis-12-Dichloroethene 96 2644 2644 (0737) 11702 100000 11

10162012Page 78 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07836d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0856) 6291 500000 40(a)

42 Chloroform 83 2839 2839 (0791) 17974 100000 098(a)

44 Cyclohexane 56 2778 2778 (0774) 14380 100000 075(a)

43 111-Trichloroethane 97 2973 2973 (0828) 14264 100000 092(a)

45 Carbon Tetrachloride 117 2924 2924 (0815) 11168 100000 089(a)

48 Benzene 78 3254 3254 (0468) 45050 100000 10

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 599539 500000 49

49 12-Dichloroethane 62 3412 3412 (0951) 15679 100000 10

52 Fluorobenzene 96 3589 3589 (1000) 2307227 500000

54 Trichloroethene 95 3735 3735 (1041) 11865 100000 11

56 Methyl cyclohexane 83 3723 3723 (1037) 10486 100000 068(a)

57 12-Dichloropropane 63 4192 4192 (1168) 12728 100000 10

68 Bromodichloromethane 83 4266 4266 (1189) 14807 100000 10

67 cis-13-Dichloropropene 75 4906 4906 (0706) 18914 100000 095(a)

70 4-Methyl-2-Pentanone 43 5625 5625 (0810) 67258 500000 50

$ 65 Toluene-d8 (SUR) 98 5101 5101 (0734) 2133452 500000 49

66 Toluene 91 5156 5156 (0742) 51238 100000 10

64 trans-13-Dichloropropene 75 5650 5650 (0813) 17115 100000 095(a)

69 112-Trichloroethane 83 5826 5826 (0839) 8636 100000 10

71 Tetrachloroethene 166 5582 5582 (0803) 10238 100000 088(a)

73 2-Hexanone 43 6674 6674 (0960) 49729 500000 50

74 Dibromochloromethane 129 6015 6015 (0866) 11301 100000 098(a)

77 12-Dibromoethane 107 6265 6265 (0902) 9735 100000 097(a)

78 Chlorobenzene-d5 117 6948 6948 (1000) 1875221 500000

79 Chlorobenzene 112 6972 6972 (1004) 33596 100000 10

81 Ethylbenzene 106 7064 7064 (1017) 17061 100000 096(a)

82 m+p-Xylene 106 7271 7271 (1046) 44761 200000 20

84 o-Xylene 106 7856 7856 (1131) 21499 100000 097(a)

85 Styrene 104 7942 7942 (1143) 36217 100000 096(a)

86 Bromoform 173 7911 7911 (1139) 7698 100000 096(a)

88 Isopropylbenzene 105 8344 8344 (1201) 49933 100000 094(a)

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 823604 500000 48

92 1122-Tetrachloroethane 83 9112 9112 (0871) 13823 100000 10

105 13-Dichlorobenzene 146 10332 10332 (0987) 26644 100000 099(a)

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1055978 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 28798 100000 10

111 12-Dichlorobenzene 146 11148 11148 (1065) 25972 100000 10(H)

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 2725 100000 11

114 124-Trichlorobenzene 180 12971 12971 (1239) 13808 100000 11

M 120 12-Dichloroethene (Total) 100 21147 200000 21

M 121 Xylene (Total) 100 66260 300000 30

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

H - Operator selected an alternate compound hit

10162012Page 79 of 323

Data File e07836d

Date 17-SEP-2012 0449

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL1 Operator GCMS VOAMS5

10162012Page 80 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07838d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07838dLab Smp Id IC-VMCAL2 Inj Date 17-SEP-2012 0536 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL2Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 4 Calibration Sample Level 2Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 39416 500000 48

3 Chloromethane 50 1016 1016 (0283) 83523 500000 48

4 Vinyl Chloride 62 1022 1022 (0285) 66919 500000 49

6 Bromomethane 94 1169 1169 (0326) 33032 500000 55

5 Chloroethane 64 1230 1230 (0343) 29332 500000 58

7 Trichlorofluoromethane 101 1291 1291 (0360) 49780 500000 45

14 Freon TF 101 1559 1559 (0434) 37580 500000 48

15 11-Dichloroethene 96 1541 1541 (0429) 31234 500000 45

16 Acetone 58 1894 1894 (0528) 13342 150000 16

18 Carbon Disulfide 76 1553 1553 (0433) 149121 500000 47

27 Methyl Acetate 74 1961 1961 (0546) 10660 500000 54

22 Methylene Chloride 49 1851 1851 (0516) 86862 500000 53

28 MTBE 73 2016 2016 (0562) 167790 500000 53

25 trans-12-Dichloroethene 96 1937 1937 (0540) 45844 500000 48

30 11-Dichloroethane 63 2296 2296 (0640) 104265 500000 49

36 cis-12-Dichloroethene 96 2644 2644 (0737) 55218 500000 51

10162012Page 81 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07838d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0857) 19260 150000 12

42 Chloroform 83 2839 2839 (0791) 94697 500000 52

44 Cyclohexane 56 2772 2772 (0772) 96765 500000 51

43 111-Trichloroethane 97 2973 2973 (0828) 71766 500000 46

45 Carbon Tetrachloride 117 2924 2924 (0815) 54679 500000 44

48 Benzene 78 3254 3254 (0468) 227079 500000 53

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 630441 500000 52

49 12-Dichloroethane 62 3412 3412 (0951) 78926 500000 52

52 Fluorobenzene 96 3589 3589 (1000) 2304638 500000

54 Trichloroethene 95 3735 3735 (1041) 50527 500000 46

56 Methyl cyclohexane 83 3717 3717 (1036) 79279 500000 52

57 12-Dichloropropane 63 4192 4192 (1168) 64209 500000 50

68 Bromodichloromethane 83 4272 4272 (1190) 72835 500000 49

67 cis-13-Dichloropropene 75 4906 4906 (0706) 95905 500000 50

70 4-Methyl-2-Pentanone 43 5625 5625 (0810) 195851 150000 15

$ 65 Toluene-d8 (SUR) 98 5101 5101 (0734) 2179204 500000 52

66 Toluene 91 5156 5156 (0742) 243768 500000 51

64 trans-13-Dichloropropene 75 5643 5643 (0812) 85943 500000 49

69 112-Trichloroethane 83 5820 5820 (0838) 42154 500000 51

71 Tetrachloroethene 166 5576 5576 (0803) 51530 500000 46

73 2-Hexanone 43 6680 6680 (0961) 148758 150000 15

74 Dibromochloromethane 129 6015 6015 (0866) 54107 500000 48

77 12-Dibromoethane 107 6259 6259 (0901) 49066 500000 51

78 Chlorobenzene-d5 117 6948 6948 (1000) 1811885 500000

79 Chlorobenzene 112 6972 6972 (1004) 162793 500000 50

81 Ethylbenzene 106 7058 7058 (1016) 81955 500000 48

82 m+p-Xylene 106 7271 7271 (1046) 208423 100000 97

84 o-Xylene 106 7856 7856 (1131) 102832 500000 48

85 Styrene 104 7942 7942 (1143) 179367 500000 50

86 Bromoform 173 7911 7911 (1139) 36074 500000 46

88 Isopropylbenzene 105 8344 8344 (1201) 244766 500000 48

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 813301 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 63947 500000 50

105 13-Dichlorobenzene 146 10325 10325 (0987) 126663 500000 50

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 998386 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 130929 500000 49

111 12-Dichlorobenzene 146 11148 11148 (1065) 121236 500000 50

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 11615 500000 51

114 124-Trichlorobenzene 180 12965 12965 (1239) 61295 500000 50

M 120 12-Dichloroethene (Total) 100 101062 100000 99

M 121 Xylene (Total) 100 311255 150000 14

10162012Page 82 of 323

Data File e07838d

Date 17-SEP-2012 0536

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL2 Operator GCMS VOAMS5

10162012Page 83 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07839d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07839dLab Smp Id ICIS-VMCAL3 Inj Date 17-SEP-2012 0600 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info ICIS-VMCAL3Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 5 Calibration Sample Level 3Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 167418 200000 20

3 Chloromethane 50 1016 1016 (0283) 353287 200000 20

4 Vinyl Chloride 62 1016 1016 (0283) 281874 200000 20

6 Bromomethane 94 1175 1175 (0327) 118799 200000 19

5 Chloroethane 64 1230 1230 (0343) 107678 200000 21

7 Trichlorofluoromethane 101 1291 1291 (0360) 228376 200000 20

14 Freon TF 101 1559 1559 (0434) 157867 200000 20

15 11-Dichloroethene 96 1540 1540 (0429) 147259 200000 21

16 Acetone 58 1888 1888 (0526) 17849 200000 20

18 Carbon Disulfide 76 1559 1559 (0434) 648801 200000 20

27 Methyl Acetate 74 1955 1955 (0545) 39926 200000 20

22 Methylene Chloride 49 1851 1851 (0516) 340378 200000 20

28 MTBE 73 2016 2016 (0562) 658123 200000 20

25 trans-12-Dichloroethene 96 1943 1943 (0541) 203500 200000 21

30 11-Dichloroethane 63 2303 2303 (0642) 465144 200000 21

36 cis-12-Dichloroethene 96 2644 2644 (0737) 233129 200000 21

10162012Page 84 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07839d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0856) 36552 200000 22

42 Chloroform 83 2839 2839 (0791) 383084 200000 20

44 Cyclohexane 56 2778 2778 (0774) 383104 200000 19

43 111-Trichloroethane 97 2973 2973 (0828) 333961 200000 21

45 Carbon Tetrachloride 117 2924 2924 (0815) 265527 200000 21

48 Benzene 78 3254 3254 (0468) 968083 200000 21

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 611357 500000 49

49 12-Dichloroethane 62 3412 3412 (0951) 312991 200000 20

52 Fluorobenzene 96 3589 3589 (1000) 2376396 500000

54 Trichloroethene 95 3735 3735 (1041) 229465 200000 20

56 Methyl cyclohexane 83 3723 3723 (1037) 312424 200000 20

57 12-Dichloropropane 63 4192 4192 (1168) 266559 200000 20

68 Bromodichloromethane 83 4266 4266 (1189) 302742 200000 20

67 cis-13-Dichloropropene 75 4906 4906 (0705) 412847 200000 20

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 271059 200000 20

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2252606 500000 50

66 Toluene 91 5156 5156 (0741) 1095520 200000 22

64 trans-13-Dichloropropene 75 5643 5643 (0812) 369516 200000 20

69 112-Trichloroethane 83 5820 5820 (0837) 175853 200000 20

71 Tetrachloroethene 166 5576 5576 (0802) 258990 200000 22

73 2-Hexanone 43 6680 6680 (0961) 205286 200000 20

74 Dibromochloromethane 129 6015 6015 (0865) 237421 200000 20

77 12-Dibromoethane 107 6259 6259 (0900) 210900 200000 20

78 Chlorobenzene-d5 117 6954 6954 (1000) 1921967 500000

79 Chlorobenzene 112 6972 6972 (1003) 714336 200000 21

81 Ethylbenzene 106 7064 7064 (1016) 380762 200000 21

82 m+p-Xylene 106 7277 7277 (1046) 968280 400000 42

84 o-Xylene 106 7856 7856 (1130) 472158 200000 21

85 Styrene 104 7942 7942 (1142) 809158 200000 21

86 Bromoform 173 7911 7911 (1138) 165267 200000 20

88 Isopropylbenzene 105 8344 8344 (1200) 1199765 200000 22

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 847619 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 277413 200000 20

105 13-Dichlorobenzene 146 10325 10325 (0987) 557342 200000 21

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1048295 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 574816 200000 21

111 12-Dichlorobenzene 146 11148 11148 (1065) 528396 200000 21

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 45388 200000 19

114 124-Trichlorobenzene 180 12965 12965 (1239) 264648 200000 21

M 120 12-Dichloroethene (Total) 100 436629 400000 42

M 121 Xylene (Total) 100 1440438 600000 63

10162012Page 85 of 323

Data File e07839d

Date 17-SEP-2012 0600

Client ID Instrument VOAMS5i

Sample Info ICIS-VMCAL3 Operator GCMS VOAMS5

10162012Page 86 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07840d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07840dLab Smp Id IC-VMCAL4 Inj Date 17-SEP-2012 0623 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL4Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 6 Calibration Sample Level 4Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 450014 500000 53

3 Chloromethane 50 1010 1010 (0281) 935453 500000 52

4 Vinyl Chloride 62 1016 1016 (0283) 757876 500000 53

6 Bromomethane 94 1175 1175 (0327) 307121 500000 49

5 Chloroethane 64 1230 1230 (0342) 284219 500000 54

7 Trichlorofluoromethane 101 1290 1290 (0359) 566305 500000 49

14 Freon TF 101 1565 1565 (0435) 443949 500000 55

15 11-Dichloroethene 96 1540 1540 (0428) 355088 500000 49

16 Acetone 58 1888 1888 (0525) 43750 500000 50

18 Carbon Disulfide 76 1559 1559 (0434) 1763903 500000 53

27 Methyl Acetate 74 1961 1961 (0546) 101112 500000 49

22 Methylene Chloride 49 1851 1851 (0515) 840419 500000 49

28 MTBE 73 2016 2016 (0561) 1636664 500000 50

25 trans-12-Dichloroethene 96 1943 1943 (0540) 521911 500000 53

30 11-Dichloroethane 63 2302 2302 (0640) 1121930 500000 51

36 cis-12-Dichloroethene 96 2644 2644 (0735) 567238 500000 50

10162012Page 87 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07840d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0854) 89217 500000 54

42 Chloroform 83 2839 2839 (0790) 974788 500000 51

44 Cyclohexane 56 2778 2778 (0773) 1067735 500000 54

43 111-Trichloroethane 97 2973 2973 (0827) 821993 500000 51

45 Carbon Tetrachloride 117 2924 2924 (0813) 675330 500000 52

48 Benzene 78 3254 3254 (0468) 2380099 500000 51

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0934) 613057 500000 48

49 12-Dichloroethane 62 3412 3412 (0949) 785178 500000 50

52 Fluorobenzene 96 3595 3595 (1000) 2400971 500000

54 Trichloroethene 95 3735 3735 (1039) 562086 500000 49

56 Methyl cyclohexane 83 3723 3723 (1036) 894738 500000 56

57 12-Dichloropropane 63 4192 4192 (1166) 655380 500000 50

68 Bromodichloromethane 83 4272 4272 (1188) 754124 500000 49

67 cis-13-Dichloropropene 75 4906 4906 (0705) 1024782 500000 49

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 697282 500000 49

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2273339 500000 50

66 Toluene 91 5162 5162 (0742) 2719268 500000 52

64 trans-13-Dichloropropene 75 5649 5649 (0812) 938808 500000 50

69 112-Trichloroethane 83 5820 5820 (0837) 432262 500000 49

71 Tetrachloroethene 166 5576 5576 (0802) 639002 500000 52

73 2-Hexanone 43 6680 6680 (0961) 526223 500000 50

74 Dibromochloromethane 129 6015 6015 (0865) 599464 500000 49

77 12-Dibromoethane 107 6259 6259 (0900) 524614 500000 50

78 Chlorobenzene-d5 117 6954 6954 (1000) 1964266 500000

79 Chlorobenzene 112 6972 6972 (1003) 1781568 500000 51

81 Ethylbenzene 106 7064 7064 (1016) 955894 500000 51

82 m+p-Xylene 106 7277 7277 (1046) 2423002 100000 100

84 o-Xylene 106 7862 7862 (1131) 1181273 500000 51

85 Styrene 104 7942 7942 (1142) 2064560 500000 52

86 Bromoform 173 7911 7911 (1138) 430943 500000 51

88 Isopropylbenzene 105 8350 8350 (1201) 3014281 500000 54

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 870646 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 702309 500000 50

105 13-Dichlorobenzene 146 10331 10331 (0987) 1421450 500000 51

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1082388 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 1464915 500000 51

111 12-Dichlorobenzene 146 11154 11154 (1066) 1324016 500000 50

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 120062 500000 49

114 124-Trichlorobenzene 180 12971 12971 (1239) 678119 500000 51

M 120 12-Dichloroethene (Total) 100 1089149 100000 100

M 121 Xylene (Total) 100 3604275 150000 160

10162012Page 88 of 323

Data File e07840d

Date 17-SEP-2012 0623

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL4 Operator GCMS VOAMS5

10162012Page 89 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07841d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07841dLab Smp Id IC-VMCAL5 Inj Date 17-SEP-2012 0646 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL5Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 7 Calibration Sample Level 5Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 1798263 200000 200

3 Chloromethane 50 1010 1010 (0281) 3551906 200000 190

4 Vinyl Chloride 62 1016 1016 (0283) 2954383 200000 200

6 Bromomethane 94 1175 1175 (0327) 1285567 200000 190

5 Chloroethane 64 1230 1230 (0342) 1005976 200000 180

7 Trichlorofluoromethane 101 1291 1291 (0359) 2495326 200000 200

14 Freon TF 101 1565 1565 (0435) 1913025 200000 220

15 11-Dichloroethene 96 1541 1541 (0429) 1549102 200000 200

16 Acetone 58 1894 1894 (0527) 164598 200000 180

18 Carbon Disulfide 76 1559 1559 (0434) 7384049 200000 210

27 Methyl Acetate 74 1961 1961 (0546) 407713 200000 190

22 Methylene Chloride 49 1851 1851 (0515) 3225631 200000 180

28 MTBE 73 2016 2016 (0561) 7002522 200000 200

25 trans-12-Dichloroethene 96 1943 1943 (0540) 2044335 200000 200

30 11-Dichloroethane 63 2303 2303 (0640) 4556341 200000 200

36 cis-12-Dichloroethene 96 2650 2650 (0737) 2267968 200000 190

10162012Page 90 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07841d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0854) 377317 200000 220

42 Chloroform 83 2839 2839 (0790) 4002506 200000 200

44 Cyclohexane 56 2784 2784 (0774) 4704103 200000 220

43 111-Trichloroethane 97 2979 2979 (0829) 3633125 200000 210

45 Carbon Tetrachloride 117 2930 2930 (0815) 2970592 200000 220

48 Benzene 78 3260 3260 (0468) 9863557 200000 210

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 676105 500000 50

49 12-Dichloroethane 62 3418 3418 (0951) 3236838 200000 190

52 Fluorobenzene 96 3595 3595 (1000) 2534623 500000

54 Trichloroethene 95 3741 3741 (1041) 2397838 200000 200

56 Methyl cyclohexane 83 3729 3729 (1037) 3740947 200000 220

57 12-Dichloropropane 63 4199 4199 (1168) 2762116 200000 200

68 Bromodichloromethane 83 4272 4272 (1188) 3283607 200000 200

67 cis-13-Dichloropropene 75 4912 4912 (0706) 4330221 200000 200

70 4-Methyl-2-Pentanone 43 5631 5631 (0809) 2892746 200000 200

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2337515 500000 50

66 Toluene 91 5162 5162 (0742) 10779721 200000 200

64 trans-13-Dichloropropene 75 5656 5656 (0813) 3942425 200000 200

69 112-Trichloroethane 83 5826 5826 (0837) 1754301 200000 190

71 Tetrachloroethene 166 5582 5582 (0802) 2589541 200000 210

73 2-Hexanone 43 6686 6686 (0961) 2211715 200000 210

74 Dibromochloromethane 129 6021 6021 (0865) 2498269 200000 200

77 12-Dibromoethane 107 6265 6265 (0900) 2110766 200000 200

78 Chlorobenzene-d5 117 6960 6960 (1000) 2007362 500000

79 Chlorobenzene 112 6978 6978 (1003) 7007520 200000 200

81 Ethylbenzene 106 7076 7076 (1017) 3881643 200000 200

82 m+p-Xylene 106 7289 7289 (1047) 9786882 400000 410

84 o-Xylene 106 7869 7869 (1131) 4809215 200000 200

85 Styrene 104 7954 7954 (1143) 8412645 200000 210

86 Bromoform 173 7923 7923 (1138) 1812795 200000 210

88 Isopropylbenzene 105 8356 8356 (1201) 12317103 200000 220(A)

$ 89 Bromofluorobenzene (SUR) 174 8716 8716 (0832) 929176 500000 51

92 1122-Tetrachloroethane 83 9124 9124 (0871) 2898768 200000 200

105 13-Dichlorobenzene 146 10344 10344 (0987) 5787314 200000 200

108 14-Dichlorobenzene-d4 152 10478 10478 (1000) 1134091 500000

109 14-Dichlorobenzene 146 10502 10502 (1002) 5901891 200000 200

111 12-Dichlorobenzene 146 11167 11167 (1066) 5328621 200000 190

112 12-Dibromo-3-chloropropane 75 12240 12240 (1168) 472744 200000 180

114 124-Trichlorobenzene 180 12971 12971 (1238) 2596959 200000 190

M 120 12-Dichloroethene (Total) 100 4312303 400000 380

M 121 Xylene (Total) 100 14596097 600000 620

QC Flag Legend

A - Target compound detected but quantitated amountexceeded maximum amount

10162012Page 91 of 323

Data File e07841d

Date 17-SEP-2012 0646

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL5 Operator GCMS VOAMS5

10162012Page 92 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07842d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07842dLab Smp Id IC-VMCAL6 Inj Date 17-SEP-2012 0710 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL6Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 8 Calibration Sample Level 6Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 4551928 500000 450

3 Chloromethane 50 1010 1010 (0280) 8902969 500000 410

4 Vinyl Chloride 62 1016 1016 (0282) 7332518 500000 420

6 Bromomethane 94 1175 1175 (0326) 3429373 500000 450

5 Chloroethane 64 1230 1230 (0341) 2426216 500000 380

7 Trichlorofluoromethane 101 1297 1297 (0360) 6618134 500000 470

14 Freon TF 101 1571 1571 (0436) 5130629 500000 520(A)

15 11-Dichloroethene 96 1547 1547 (0429) 4214942 500000 490

16 Acetone 58 1894 1894 (0526) 441742 500000 420

18 Carbon Disulfide 76 1559 1559 (0433) 18433408 500000 460

27 Methyl Acetate 74 1961 1961 (0545) 1074355 500000 440

22 Methylene Chloride 49 1851 1851 (0514) 8533685 500000 410

28 MTBE 73 2022 2022 (0562) 17351574 500000 440

25 trans-12-Dichloroethene 96 1943 1943 (0540) 5633771 500000 470

30 11-Dichloroethane 63 2302 2302 (0639) 12326764 500000 460

36 cis-12-Dichloroethene 96 2650 2650 (0736) 6324299 500000 460

10162012Page 93 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07842d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3083 3083 (0856) 1055008 500000 530(A)

42 Chloroform 83 2845 2845 (0790) 11152231 500000 480

44 Cyclohexane 56 2790 2790 (0775) 12852489 500000 540(A)

43 111-Trichloroethane 97 2985 2985 (0829) 10199723 500000 520(A)

45 Carbon Tetrachloride 117 2936 2936 (0815) 8405131 500000 540(A)

48 Benzene 78 3260 3260 (0468) 21876514 500000 410

$ 47 12-Dichloroethane-d4 (SUR) 65 3369 3369 (0936) 782507 500000 51

49 12-Dichloroethane 62 3424 3424 (0951) 9046377 500000 480

52 Fluorobenzene 96 3601 3601 (1000) 2895790 500000

54 Trichloroethene 95 3753 3753 (1042) 7026524 500000 510(A)

56 Methyl cyclohexane 83 3741 3741 (1039) 10227785 500000 530(A)

57 12-Dichloropropane 63 4205 4205 (1168) 7913672 500000 500

68 Bromodichloromethane 83 4284 4284 (1190) 9374106 500000 510(A)

67 cis-13-Dichloropropene 75 4924 4924 (0706) 12299317 500000 520(A)

70 4-Methyl-2-Pentanone 43 5649 5649 (0810) 8212153 500000 510(A)

$ 65 Toluene-d8 (SUR) 98 5113 5113 (0733) 2600040 500000 50

66 Toluene 91 5168 5168 (0741) 23868197 500000 400

64 trans-13-Dichloropropene 75 5668 5668 (0813) 11373599 500000 530(A)

69 112-Trichloroethane 83 5838 5838 (0837) 5071317 500000 500(A)

71 Tetrachloroethene 166 5594 5594 (0802) 7239654 500000 520(A)

73 2-Hexanone 43 6698 6698 (0961) 5590902 500000 470

74 Dibromochloromethane 129 6033 6033 (0865) 7227226 500000 530(A)

77 12-Dibromoethane 107 6277 6277 (0900) 5952425 500000 500(A)

78 Chlorobenzene-d5 117 6972 6972 (1000) 2224153 500000

79 Chlorobenzene 112 6997 6997 (1003) 18374405 500000 460

81 Ethylbenzene 106 7094 7094 (1017) 10693410 500000 500(A)

82 m+p-Xylene 106 7308 7308 (1048) 23238078 100000 880

84 o-Xylene 106 7887 7887 (1131) 12821590 500000 490

85 Styrene 104 7966 7966 (1143) 19831782 500000 440

86 Bromoform 173 7942 7942 (1139) 4974461 500000 520(A)

88 Isopropylbenzene 105 8368 8368 (1200) 26165908 500000 420(A)

$ 89 Bromofluorobenzene (SUR) 174 8728 8728 (0832) 954872 500000 51

92 1122-Tetrachloroethane 83 9143 9143 (0871) 7365342 500000 490

105 13-Dichlorobenzene 146 10362 10362 (0987) 14243841 500000 480

108 14-Dichlorobenzene-d4 152 10496 10496 (1000) 1163568 500000

109 14-Dichlorobenzene 146 10526 10526 (1003) 14602396 500000 470

111 12-Dichlorobenzene 146 11185 11185 (1066) 13405399 500000 480

112 12-Dibromo-3-chloropropane 75 12246 12246 (1167) 1274610 500000 480

114 124-Trichlorobenzene 180 12977 12977 (1236) 6669727 500000 470

M 120 12-Dichloroethene (Total) 100 11958070 100000 940

M 121 Xylene (Total) 100 36059668 150000 1400

QC Flag Legend

A - Target compound detected but quantitated amountexceeded maximum amount

10162012Page 94 of 323

Data File e07842d

Date 17-SEP-2012 0710

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL6 Operator GCMS VOAMS5

10162012Page 95 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10112012 2050

09172012 0449

09172012 0710

CCVIS 460-1316562

Rtx-VMS

TestAmerica Edison

Lab File ID e08976d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Dichlorodifluoromethane 0194701761 01000 221 200 105 250Ave

Chloromethane 0322303733 01000 173 200 -137 250Ave

Vinyl chloride 0274402985 01000 184 200 -81 250Ave

Bromomethane 0159401312 01000 243 200 215 250Ave

Chloroethane 0127501099 01000 232 200 160 250Ave

Trichlorofluoromethane 0296002422 01000 244 200 222 250Ave

11-Dichloroethene 0161001496 01000 215 200 76 250Ave

Carbon disulfide 0655806887 01000 190 200 -48 250Ave

112-Trichloro-122-trifluoroethane

0198901691 01000 235 200 176 250Ave

Methylene Chloride 0341503576 01000 191 200 -45 250Ave

Acetone 0021400184 01000 233 200 164 250Ave

trans-12-Dichloroethene 0208902052 01000 204 200 18 250Ave

Methyl acetate 0037700426 01000 177 200 -115 250Ave

Methyl tert-butyl ether 0665806838 01000 195 200 -26 250Ave

11-Dichloroethane 0443404582 01000 194 200 -32 250Ave

cis-12-Dichloroethene 0227602361 01000 193 200 -36 250Ave

Cyclohexane 0338904145 01000 163 200 -183 250Ave

Chloroform 0397703982 01000 200 200 -01 250Ave

Carbon tetrachloride 0281602705 01000 208 200 41 250Ave

111-Trichloroethane 0352303375 01000 209 200 44 250Ave

2-Butanone (MEK) 0035400341 01000 208 200 40 250Ave

Benzene 10301190 01000 173 200 -134 250Ave

12-Dichloroethane 0331603284 01000 202 200 10 250Ave

Methylcyclohexane 0280603325 01000 169 200 -156 250Ave

Trichloroethene 0228602385 01000 192 200 -41 250Ave

12-Dichloropropane 0242002756 01000 176 200 -122 250Ave

Dichlorobromomethane 0303603195 01000 190 200 -50 250Ave

cis-13-Dichloropropene 0438605308 01000 165 200 -174 250Ave

Toluene 12151323 01000 184 200 -81 250Ave

Tetrachloroethene 0302803113 01000 195 200 -27 250Ave

4-Methyl-2-pentanone (MIBK) 0273203593 01000 152 200 -240 250Ave

trans-13-Dichloropropene 0396604819 01000 165 200 -177 250Ave

112-Trichloroethane 0185102264 01000 164 200 -182 250Ave

Chlorodibromomethane 0265003083 01000 172 200 -141 250Ave

12-Dibromoethane 0231002670 01000 173 200 -135 250Ave

2-Hexanone 0209702668 01000 157 200 -214 250Ave

Chlorobenzene 0830208882 01000 187 200 -65 250Ave

Ethylbenzene 0437104756 01000 184 200 -81 250Ave

m-Xylene amp p-Xylene 0555805917 01000 376 400 -61 250Ave

o-Xylene 0545405886 01000 185 200 -73 250Ave

FORM VII 8260B

10162012Page 96 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10112012 2050

09172012 0449

09172012 0710

CCVIS 460-1316562

Rtx-VMS

TestAmerica Edison

Lab File ID e08976d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Bromoform 0188102147 01000 175 200 -124 250Ave

Styrene 092181000 01000 184 200 -78 250Ave

Isopropylbenzene 13421415 01000 190 200 -52 250Ave

1122-Tetrachloroethane 0512306462 01000 159 200 -207 250Ave

13-Dichlorobenzene 11861279 01000 186 200 -72 250Ave

14-Dichlorobenzene 12311326 01000 186 200 -72 250Ave

12-Dichlorobenzene 11211209 01000 185 200 -73 250Ave

12-Dibromo-3-Chloropropane 0086101130 01000 152 200 -238 250Ave

124-Trichlorobenzene 0630306118 01000 206 200 30 250Ave

12-Dichloroethane-d4 (Surr) 0310902638 01000 589 500 178 250Ave

Toluene-d8 (Surr) 11551167 01000 495 500 -11 250Ave

4-Bromofluorobenzene 0811108079 01000 502 500 04 250Ave

FORM VII 8260B

10162012Page 97 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08976d Report Date 11-Oct-2012 2130

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08976dLab Smp Id CCVIS Inj Date 11-OCT-2012 2050 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info CCVISMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 1 Continuing Calibration SampleDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0900 0900 (0250) 102235 200000 22

3 Chloromethane 50 1016 1016 (0282) 169224 200000 17

4 Vinyl Chloride 62 1028 1028 (0286) 144069 200000 18

6 Bromomethane 94 1181 1181 (0328) 83687 200000 24

5 Chloroethane 64 1242 1242 (0345) 66969 200000 23

7 Trichlorofluoromethane 101 1303 1303 (0362) 155393 200000 24

14 Freon TF 101 1577 1577 (0438) 104446 200000 24

15 11-Dichloroethene 96 1553 1553 (0431) 84531 200000 22

16 Acetone 58 1894 1894 (0526) 11228 200000 23

18 Carbon Disulfide 76 1571 1571 (0436) 344348 200000 19

27 Methyl Acetate 74 1967 1967 (0546) 19813 200000 18

22 Methylene Chloride 49 1864 1864 (0518) 179288 200000 19

28 MTBE 73 2022 2022 (0562) 349596 200000 19

25 trans-12-Dichloroethene 96 1949 1949 (0541) 109681 200000 20

30 11-Dichloroethane 63 2309 2309 (0641) 232818 200000 19

36 cis-12-Dichloroethene 96 2656 2656 (0738) 119502 200000 19

10162012Page 98 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08976d Report Date 11-Oct-2012 2130

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0854) 18598 200000 21

42 Chloroform 83 2845 2845 (0790) 208815 200000 20

44 Cyclohexane 56 2784 2784 (0773) 177923 200000 16

43 111-Trichloroethane 97 2985 2985 (0829) 185002 200000 21

45 Carbon Tetrachloride 117 2937 2937 (0815) 147853 200000 21

48 Benzene 78 3260 3260 (0469) 476925 200000 17

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0934) 408134 500000 59

49 12-Dichloroethane 62 3418 3418 (0949) 174132 200000 20

52 Fluorobenzene 96 3601 3601 (1000) 1312656 500000

54 Trichloroethene 95 3741 3741 (1039) 120041 200000 19

56 Methyl cyclohexane 83 3729 3729 (1036) 147336 200000 17

57 12-Dichloropropane 63 4199 4199 (1166) 127078 200000 18

68 Bromodichloromethane 83 4272 4272 (1186) 159386 200000 19

67 cis-13-Dichloropropene 75 4912 4912 (0706) 203059 200000 16

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 126467 200000 15

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1336847 500000 49

66 Toluene 91 5162 5162 (0742) 562689 200000 18

64 trans-13-Dichloropropene 75 5649 5649 (0812) 183587 200000 16

69 112-Trichloroethane 83 5820 5820 (0837) 85707 200000 16

71 Tetrachloroethene 166 5582 5582 (0803) 140177 200000 19

73 2-Hexanone 43 6680 6680 (0961) 97080 200000 16

74 Dibromochloromethane 129 6021 6021 (0866) 122657 200000 17

77 12-Dibromoethane 107 6265 6265 (0901) 106920 200000 17

78 Chlorobenzene-d5 117 6954 6954 (1000) 1157341 500000

79 Chlorobenzene 112 6972 6972 (1003) 384334 200000 19

81 Ethylbenzene 106 7064 7064 (1016) 202362 200000 18

82 m+p-Xylene 106 7277 7277 (1046) 514606 400000 38

84 o-Xylene 106 7862 7862 (1131) 252476 200000 18

85 Styrene 104 7942 7942 (1142) 426740 200000 18

86 Bromoform 173 7911 7911 (1138) 87078 200000 18

88 Isopropylbenzene 105 8350 8350 (1201) 621124 200000 19

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 541700 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 136860 200000 16

105 13-Dichlorobenzene 146 10331 10331 (0987) 316835 200000 18

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 667834 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 328709 200000 18

111 12-Dichlorobenzene 146 11148 11148 (1065) 299393 200000 18

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 23001 200000 15

114 124-Trichlorobenzene 180 12977 12977 (1240) 168371 200000 21

M 120 12-Dichloroethene (Total) 100 229183 400000 40

M 121 Xylene (Total) 100 767082 600000 56

10162012Page 99 of 323

Data File e08976d

Date 11-OCT-2012 2050

Client ID Instrument VOAMS5i

Sample Info CCVIS Operator GCMS VOAMS5

10162012Page 100 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10122012 0114

09172012 0449

09172012 0710

CCV 460-13165610

Rtx-VMS

TestAmerica Edison

Lab File ID e08987d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Dichlorodifluoromethane 0166601761 01000 189 200 -54 250Ave

Chloromethane 0311403733 01000 167 200 -166 250Ave

Vinyl chloride 0256002985 01000 172 200 -142 250Ave

Bromomethane 0162301312 01000 247 200 237 250Ave

Chloroethane 0127201099 01000 231 200 157 250Ave

Trichlorofluoromethane 0257102422 01000 212 200 62 250Ave

11-Dichloroethene 0184901496 01000 247 200 236 250Ave

112-Trichloro-122-trifluoroethane

0225501691 01000 267 200 334 250Ave

Carbon disulfide 0788506887 01000 229 200 145 250Ave

Methylene Chloride 0351303576 01000 196 200 -18 250Ave

Acetone 0022000184 01000 239 200 197 250Ave

trans-12-Dichloroethene 0232002052 01000 226 200 130 250Ave

Methyl acetate 0048700426 01000 228 200 141 250Ave

Methyl tert-butyl ether 0769506838 01000 225 200 125 250Ave

11-Dichloroethane 0469804582 01000 205 200 25 250Ave

cis-12-Dichloroethene 0240902361 01000 204 200 20 250Ave

Cyclohexane 0384004145 01000 185 200 -74 250Ave

Chloroform 0438203982 01000 220 200 100 250Ave

Carbon tetrachloride 0291802705 01000 216 200 79 250Ave

111-Trichloroethane 0362803375 01000 215 200 75 250Ave

2-Butanone (MEK) 0042500341 01000 250 200 248 250Ave

Benzene 11151190 01000 188 200 -62 250Ave

12-Dichloroethane 0359603284 01000 219 200 95 250Ave

Methylcyclohexane 0344803325 01000 207 200 37 250Ave

Trichloroethene 0248302385 01000 208 200 41 250Ave

12-Dichloropropane 0265202756 01000 192 200 -38 250Ave

Dichlorobromomethane 0339803195 01000 213 200 63 250Ave

cis-13-Dichloropropene 0490405308 01000 185 200 -76 250Ave

Toluene 12801323 01000 194 200 -32 250Ave

Tetrachloroethene 0323103113 01000 208 200 38 250Ave

4-Methyl-2-pentanone (MIBK) 0319703593 01000 178 200 -110 250Ave

trans-13-Dichloropropene 0454104819 01000 188 200 -58 250Ave

112-Trichloroethane 0212502264 01000 188 200 -61 250Ave

Chlorodibromomethane 0306403083 01000 199 200 -06 250Ave

12-Dibromoethane 0261302670 01000 196 200 -22 250Ave

2-Hexanone 0243802668 01000 183 200 -86 250Ave

Chlorobenzene 0879308882 01000 198 200 -10 250Ave

Ethylbenzene 0463104756 01000 195 200 -26 250Ave

m-Xylene amp p-Xylene 0587505917 01000 397 400 -07 250Ave

o-Xylene 0578505886 01000 197 200 -17 250Ave

FORM VII 8260B

10162012Page 101 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10122012 0114

09172012 0449

09172012 0710

CCV 460-13165610

Rtx-VMS

TestAmerica Edison

Lab File ID e08987d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Bromoform 0223102147 01000 208 200 39 250Ave

Styrene 099051000 01000 198 200 -09 250Ave

Isopropylbenzene 14391415 01000 203 200 17 250Ave

1122-Tetrachloroethane 0579606462 01000 179 200 -103 250Ave

13-Dichlorobenzene 12591279 01000 197 200 -15 250Ave

14-Dichlorobenzene 13061326 01000 197 200 -15 250Ave

12-Dichlorobenzene 12151209 01000 201 200 05 250Ave

12-Dibromo-3-Chloropropane 0102901130 01000 182 200 -90 250Ave

124-Trichlorobenzene 0743906118 01000 243 200 216 250Ave

12-Dichloroethane-d4 (Surr) 0320902638 01000 608 500 216 250Ave

Toluene-d8 (Surr) 11471167 01000 491 500 -18 250Ave

4-Bromofluorobenzene 0806308079 01000 499 500 -02 250Ave

FORM VII 8260B

10162012Page 102 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12abe08987d Report Date 12-Oct-2012 0132

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12abe08987dLab Smp Id CCV Inj Date 12-OCT-2012 0114 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info CCVMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12ab8260DE_09mMeth Date 12-Oct-2012 0132 ken Quant Type ISTDCal Date 12-OCT-2012 0114 Cal File e08987dAls bottle 12 Continuing Calibration SampleDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0894 (0249) 84911 200000 19

3 Chloromethane 50 1016 1016 (0283) 158694 200000 17

4 Vinyl Chloride 62 1022 1022 (0284) 130464 200000 17

6 Bromomethane 94 1181 1181 (0328) 82695 200000 25

5 Chloroethane 64 1236 1236 (0344) 64840 200000 23

7 Trichlorofluoromethane 101 1297 1297 (0361) 131020 200000 21

14 Freon TF 101 1565 1565 (0435) 114931 200000 27

15 11-Dichloroethene 96 1547 1547 (0430) 94244 200000 25

16 Acetone 58 1894 1894 (0527) 11208 200000 24

18 Carbon Disulfide 76 1565 1565 (0435) 401807 200000 23

27 Methyl Acetate 74 1961 1961 (0546) 24794 200000 23

22 Methylene Chloride 49 1857 1857 (0517) 179010 200000 20

28 MTBE 73 2022 2022 (0562) 392131 200000 22

25 trans-12-Dichloroethene 96 1943 1943 (0540) 118223 200000 23

30 11-Dichloroethane 63 2302 2302 (0640) 239419 200000 20

36 cis-12-Dichloroethene 96 2650 2650 (0737) 122782 200000 20

10162012Page 103 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12abe08987d Report Date 12-Oct-2012 0132

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0856) 21666 200000 25

42 Chloroform 83 2845 2845 (0791) 223324 200000 22

44 Cyclohexane 56 2784 2784 (0774) 195679 200000 18

43 111-Trichloroethane 97 2979 2979 (0829) 184861 200000 21

45 Carbon Tetrachloride 117 2930 2930 (0815) 148689 200000 22

48 Benzene 78 3260 3260 (0469) 501947 200000 19

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 408924 500000 61

49 12-Dichloroethane 62 3418 3418 (0951) 183231 200000 22

52 Fluorobenzene 96 3595 3595 (1000) 1274024 500000

54 Trichloroethene 95 3741 3741 (1041) 126518 200000 21

56 Methyl cyclohexane 83 3723 3723 (1036) 175700 200000 21

57 12-Dichloropropane 63 4192 4192 (1166) 135130 200000 19

68 Bromodichloromethane 83 4272 4272 (1188) 173147 200000 21

67 cis-13-Dichloropropene 75 4906 4906 (0705) 220680 200000 18

70 4-Methyl-2-Pentanone 43 5631 5631 (0810) 143892 200000 18

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1290179 500000 49

66 Toluene 91 5162 5162 (0742) 576151 200000 19

64 trans-13-Dichloropropene 75 5649 5649 (0812) 204342 200000 19

69 112-Trichloroethane 83 5820 5820 (0837) 95620 200000 19

71 Tetrachloroethene 166 5582 5582 (0803) 145404 200000 21

73 2-Hexanone 43 6680 6680 (0961) 109697 200000 18

74 Dibromochloromethane 129 6015 6015 (0865) 137888 200000 20

77 12-Dibromoethane 107 6265 6265 (0901) 117575 200000 20

78 Chlorobenzene-d5 117 6954 6954 (1000) 1125053 500000

79 Chlorobenzene 112 6972 6972 (1003) 395719 200000 20

81 Ethylbenzene 106 7064 7064 (1016) 208414 200000 19

82 m+p-Xylene 106 7277 7277 (1046) 528781 400000 40

84 o-Xylene 106 7856 7856 (1130) 260320 200000 20

85 Styrene 104 7942 7942 (1142) 445737 200000 20

86 Bromoform 173 7917 7917 (1139) 100375 200000 21

88 Isopropylbenzene 105 8344 8344 (1200) 647568 200000 20

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 536325 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 154190 200000 18

105 13-Dichlorobenzene 146 10331 10331 (0987) 335032 200000 20

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 665092 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 347387 200000 20

111 12-Dichlorobenzene 146 11148 11148 (1065) 323155 200000 20

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 27376 200000 18

114 124-Trichlorobenzene 180 12977 12977 (1240) 197894 200000 24

M 120 12-Dichloroethene (Total) 100 241005 400000 43

M 121 Xylene (Total) 100 789101 600000 59

10162012Page 104 of 323

Data File e08987d

Date 12-OCT-2012 0114

Client ID Instrument VOAMS5i

Sample Info CCV Operator GCMS VOAMS5

10162012Page 105 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07834d Report Date 17-Sep-2012 0605

TestAmerica

Data file chemVOAMS5i8260DE09-17-1217sep12be07834dLab Smp Id BFB Inj Date 17-SEP-2012 0324 Operator VOAMS 1 Inst ID VOAMS5iSmp Info BFBMisc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12bBFBDELmMeth Date 27-Feb-2012 1508 sylvanus Quant Type ISTDCal Date Cal File Als bottle 2 QC Sample BFBDil Factor 100000 Integrator HP RTE Compound Sublist allsubTarget Version 350 Sample Matrix WATERProcessing Host hpd2

Concentration Formula Amt DF Uf Vf VI CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorUf 100000 ng unit correction factorVf 100000 Volumetric correction factorVI 100000 Injection Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT (REL RT) MASS RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ==== ======== ======= ======= ============ =====

1 BFB CAS 460-00-4

2352 2600 (0000) 95 195072 000- 10000 10000

2352 2600 (0000) 50 42624 1500- 4000 2185

2352 2600 (0000) 75 102376 3000- 6000 5248

2352 2600 (0000) 96 12530 500- 900 642

2352 2600 (0000) 173 0 000- 200 000

2352 2600 (0000) 174 155200 5000- 10000 7956

2352 2600 (0000) 175 12902 500- 900 831

2352 2600 (0000) 176 148480 9500- 10100 9567

2352 2600 (0000) 177 9343 500- 900 629

-------------------------------------------------------------------------------

10162012Page 106 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

10162012Page 107 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

1 BFB

RELATIVE me ION ABUNDANCE CRITERIA ABUNDANCE

+-----+------------------------------------------+---------------------+| | | || 95 | Base Peak 100 relative abundance | 10000 || 50 | 1500 - 4000 of mass 95 | 2185 || 75 | 3000 - 6000 of mass 95 | 5248 || 96 | 500 - 900 of mass 95 | 642 || 173 | Less than 200 of mass 174 | 000 ( 000) || 174 | 5000 - 10000 of mass 95 | 7956 || 175 | 500 - 900 of mass 174 | 661 ( 831) || 176 | 9500 - 10100 of mass 174 | 7612 ( 9567) || 177 | 500 - 900 of mass 176 | 479 ( 629) |+-----+------------------------------------------+---------------------+

10162012Page 108 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

Data File chemVOAMS5i8260DE09-17-1217sep12be07834dSpectrum Avg Scans 50-52 ( 235) Background Scan 46

Location of Maximum 9500Number of points 151

mz Y mz Y mz Y mz Y+------------------+------------------+------------------+------------------+| 3500 53 | 7700 1350 | 12300 88 | 17700 9343 || 3600 1914 | 7800 695 | 12400 252 | 17800 381 || 3700 12535 | 7900 5782 | 12500 148 | 18000 35 || 3800 10760 | 8000 1455 | 12700 282 | 18300 181 || 3900 3962 | 8100 5745 | 12800 338 | 18600 248 |+------------------+------------------+------------------+------------------+| 4100 387 | 8200 905 | 12900 75 | 18700 80 || 4400 707 | 8300 42 | 13000 926 | 18800 162 || 4500 1464 | 8500 229 | 13100 166 | 18900 142 || 4600 281 | 8600 239 | 13200 7 | 19100 151 || 4700 3334 | 8700 7427 | 13400 27 | 19200 54 |+------------------+------------------+------------------+------------------+| 4800 1491 | 8800 7774 | 13700 332 | 19300 44 || 4900 8401 | 9100 1022 | 13800 172 | 19400 110 || 5000 42624 | 9200 5845 | 14000 185 | 19600 46 || 5100 13346 | 9300 8046 | 14100 1957 | 19800 171 || 5200 539 | 9400 21672 | 14200 53 | 20000 162 |+------------------+------------------+------------------+------------------+| 5300 13 | 9500 195072 | 14300 1698 | 20200 62 || 5400 14 | 9600 12530 | 14400 295 | 20300 48 || 5500 230 | 9700 551 | 14500 186 | 20400 104 || 5600 3600 | 9900 79 | 14600 115 | 20500 34 || 5700 5500 | 10000 36 | 14700 156 | 20700 223 |+------------------+------------------+------------------+------------------+| 5800 113 | 10100 136 | 14800 465 | 20900 81 || 5900 106 | 10200 36 | 14900 118 | 21500 80 || 6000 1861 | 10300 237 | 15000 105 | 21900 89 || 6100 10125 | 10400 905 | 15300 459 | 22000 60 || 6200 9219 | 10500 514 | 15400 192 | 22600 84 |+------------------+------------------+------------------+------------------+| 6300 7541 | 10600 1054 | 15700 390 | 23000 188 || 6400 270 | 10700 304 | 16000 378 | 23100 74 || 6500 625 | 11000 398 | 16100 530 | 23500 107 || 6600 51 | 11100 151 | 16400 54 | 23900 43 || 6700 378 | 11200 121 | 16700 172 | 24600 123 |+------------------+------------------+------------------+------------------+| 6800 20496 | 11300 247 | 16800 205 | 24700 37 || 6900 19976 | 11500 421 | 16900 243 | 25000 57 || 7000 1570 | 11600 358 | 17000 351 | 25200 33 || 7200 740 | 11700 1343 | 17100 439 | 25500 46 || 7300 9006 | 11800 855 | 17200 227 | 26200 43 |+------------------+------------------+------------------+------------------+| 7400 34320 | 11900 733 | 17400 155200 | 26400 63 || 7500 102376 | 12100 68 | 17500 12902 | 26500 45 || 7600 8204 | 12200 77 | 17600 148480 | |+------------------+------------------+------------------+------------------+

10162012Page 109 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08975d Report Date 11-Oct-2012 2012

TestAmerica

Data file chemVOAMS5i8260DE09-17-1211oct12be08975dLab Smp Id BFB Inj Date 11-OCT-2012 2008 Operator VOAMS 1 Inst ID VOAMS5iSmp Info BFBMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12bBFBDELmMeth Date 27-Feb-2012 1508 sylvanus Quant Type ISTDCal Date Cal File Als bottle 2 QC Sample BFBDil Factor 100000 Integrator HP RTE Compound Sublist allsubTarget Version 350 Sample Matrix WATERProcessing Host hpd2

Concentration Formula Amt DF Uf Vf VI CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorUf 100000 ng unit correction factorVf 100000 Volumetric correction factorVI 100000 Injection Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT (REL RT) MASS RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ==== ======== ======= ======= ============ =====

1 BFB CAS 460-00-4

2352 2600 (0000) 95 135522 000- 10000 10000

2352 2600 (0000) 50 29541 1500- 4000 2180

2352 2600 (0000) 75 70179 3000- 6000 5178

2352 2600 (0000) 96 8846 500- 900 653

2352 2600 (0000) 173 896 000- 200 074

2352 2600 (0000) 174 121433 5000- 10000 8960

2352 2600 (0000) 175 9704 500- 900 799

2352 2600 (0000) 176 118148 9500- 10100 9729

2352 2600 (0000) 177 7241 500- 900 613

-------------------------------------------------------------------------------

10162012Page 110 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

10162012Page 111 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

1 BFB

RELATIVE me ION ABUNDANCE CRITERIA ABUNDANCE

+-----+------------------------------------------+---------------------+| | | || 95 | Base Peak 100 relative abundance | 10000 || 50 | 1500 - 4000 of mass 95 | 2180 || 75 | 3000 - 6000 of mass 95 | 5178 || 96 | 500 - 900 of mass 95 | 653 || 173 | Less than 200 of mass 174 | 066 ( 074) || 174 | 5000 - 10000 of mass 95 | 8960 || 175 | 500 - 900 of mass 174 | 716 ( 799) || 176 | 9500 - 10100 of mass 174 | 8718 ( 9729) || 177 | 500 - 900 of mass 176 | 534 ( 613) |+-----+------------------------------------------+---------------------+

10162012Page 112 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

Data File chemVOAMS5i8260DE09-17-1211oct12be08975dSpectrum Avg Scans 50-52 ( 235) Background Scan 46

Location of Maximum 9500Number of points 149

mz Y mz Y mz Y mz Y+------------------+------------------+------------------+------------------+| 3600 1294 | 7800 45 | 13100 382 | 18200 69 || 3700 8431 | 7900 4274 | 13200 84 | 18300 115 || 3800 6991 | 8000 1313 | 13400 26 | 18600 116 || 3900 2548 | 8100 3602 | 13500 465 | 18700 340 || 4000 550 | 8200 868 | 13600 63 | 18800 34 |+------------------+------------------+------------------+------------------+| 4100 253 | 8300 128 | 13700 225 | 18900 18 || 4200 100 | 8400 171 | 13900 69 | 19900 265 || 4400 553 | 8500 53 | 14000 115 | 20100 29 || 4500 1283 | 8700 5211 | 14100 1442 | 20400 84 || 4700 1587 | 8800 4550 | 14200 269 | 20500 33 |+------------------+------------------+------------------+------------------+| 4800 651 | 9100 642 | 14300 1465 | 20600 138 || 4900 5880 | 9200 3657 | 14400 23 | 20700 20 || 5000 29536 | 9300 6715 | 14500 103 | 20900 79 || 5100 8612 | 9400 15687 | 14700 151 | 21000 74 || 5200 396 | 9500 135488 | 14800 365 | 21100 1 |+------------------+------------------+------------------+------------------+| 5300 107 | 9600 8846 | 14900 429 | 21200 140 || 5500 726 | 9700 271 | 15100 54 | 21300 52 || 5600 1691 | 9800 1 | 15300 430 | 21400 189 || 5700 4463 | 10000 110 | 15400 385 | 22100 72 || 5800 245 | 10300 207 | 15500 1021 | 22200 35 |+------------------+------------------+------------------+------------------+| 5900 116 | 10400 668 | 15600 236 | 22400 188 || 6000 1281 | 10600 562 | 15700 473 | 22600 79 || 6100 6975 | 10700 159 | 15800 3 | 22800 39 || 6200 7260 | 11000 145 | 15900 410 | 23000 95 || 6300 5465 | 11100 68 | 16100 441 | 23300 189 |+------------------+------------------+------------------+------------------+| 6400 672 | 11200 80 | 16400 208 | 23400 42 || 6500 144 | 11300 261 | 16500 57 | 23500 36 || 6600 201 | 11600 813 | 17000 641 | 23600 58 || 6700 729 | 11700 882 | 17100 38 | 24100 103 || 6800 14333 | 11800 446 | 17200 338 | 24700 36 |+------------------+------------------+------------------+------------------+| 6900 14506 | 11900 1049 | 17300 896 | 25100 40 || 7000 1361 | 12000 38 | 17400 121432 | 25500 61 || 7200 782 | 12100 249 | 17500 9704 | 25600 33 || 7300 6586 | 12400 108 | 17600 118144 | 26000 59 || 7400 24016 | 12600 138 | 17700 7241 | 26500 78 |+------------------+------------------+------------------+------------------+| 7500 70176 | 12700 39 | 17900 19 | || 7600 5444 | 12900 479 | 18000 29 | || 7700 507 | 13000 702 | 18100 322 | |+------------------+------------------+------------------+------------------+

10162012Page 113 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014U1634-04-4 Methyl tert-butyl ether 014

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 114 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

99 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

95 70-130460-00-4 4-Bromofluorobenzene

96 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 115 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 116 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08981d Report Date 12-Oct-2012 0041

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08981dLab Smp Id MB Inj Date 11-OCT-2012 2247 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info MBMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 6 QC Sample BLANKDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 381607 495518 50

52 Fluorobenzene 96 3595 3601 (1000) 1238441 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1209056 482553 48

78 Chlorobenzene-d5 117 6954 6954 (1000) 1084553 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 494380 477044 48

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 638826 500000

10162012Page 117 of 323

Data File e08981d

Date 11-OCT-2012 2247

Client ID Instrument VOAMS5i

Sample Info MB Operator GCMS VOAMS5

10162012Page 118 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1316563

Matrix e08977dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2113

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 006071-55-6 111-Trichloroethane 210

10 02275-71-8 Dichlorodifluoromethane 181

10 01074-87-3 Chloromethane 210

10 01475-01-4 Vinyl chloride 203

10 01874-83-9 Bromomethane 211

10 04096-12-8 12-Dibromo-3-Chloropropane 222

10 02195-50-1 12-Dichlorobenzene 209

10 01575-69-4 Trichlorofluoromethane 190

10 009075-35-4 11-Dichloroethene 223

10 009078-87-5 12-Dichloropropane 211

10 008076-13-1 112-Trichloro-122-trifluoroethane

203

50 2767-64-1 Acetone 250

10 01375-15-0 Carbon disulfide 218

20 03479-20-9 Methyl acetate 220

10 01875-09-2 Methylene Chloride 200

10 013156-60-5 trans-12-Dichloroethene 216

10 020124-48-1 Chlorodibromomethane 217

10 0141634-04-4 Methyl tert-butyl ether 207

10 01775-00-3 Chloroethane 201

10 01375-34-3 11-Dichloroethane 204

10 018156-59-2 cis-12-Dichloroethene 211

50 2378-93-3 2-Butanone (MEK) 214

10 008067-66-3 Chloroform 205

10 010100-41-4 Ethylbenzene 206

10 016110-82-7 Cyclohexane 208

10 006056-23-5 Carbon tetrachloride 211

10 008071-43-2 Benzene 212

10 019107-06-2 12-Dichloroethane 204

10 009079-01-6 Trichloroethene 212

10 014108-87-2 Methylcyclohexane 215

10 01275-27-4 Dichlorobromomethane 214

10 01810061-01-5 cis-13-Dichloropropene 216

50 099108-10-1 4-Methyl-2-pentanone (MIBK) 214

10 015108-88-3 Toluene 205

10 02410061-02-6 trans-13-Dichloropropene 215

FORM I 8260B

10162012Page 119 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1316563

Matrix e08977dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2113

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 01979-00-5 112-Trichloroethane 217

10 010127-18-4 Tetrachloroethene 210

50 050591-78-6 2-Hexanone 201

10 028106-93-4 12-Dibromoethane 215

10 011108-90-7 Chlorobenzene 206

30 0361330-20-7 Xylenes Total 612

10 012100-42-5 Styrene 207

10 01975-25-2 Bromoform 217

10 008098-82-8 Isopropylbenzene 207

10 01679-34-5 1122-Tetrachloroethane 210

10 014541-73-1 13-Dichlorobenzene 204

10 023106-46-7 14-Dichlorobenzene 204

10 034120-82-1 124-Trichlorobenzene 220

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

97 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 120 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08977d Report Date 11-Oct-2012 2301

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08977dLab Smp Id LCS Inj Date 11-OCT-2012 2113 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info LCSMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 2 QC Sample BSDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 92905 180886 18

3 Chloromethane 50 1016 1016 (0283) 178821 210339 21

4 Vinyl Chloride 62 1022 1028 (0284) 146748 202753 20

6 Bromomethane 94 1181 1181 (0328) 88580 210689 21

5 Chloroethane 64 1236 1242 (0344) 67759 201399 20

7 Trichlorofluoromethane 101 1297 1303 (0361) 148657 190423 19

14 Freon TF 101 1565 1577 (0435) 106548 203057 20

15 11-Dichloroethene 96 1547 1553 (0430) 94737 223085 22

16 Acetone 58 1900 1894 (0529) 14083 249674 25

18 Carbon Disulfide 76 1565 1571 (0435) 377236 218062 22

27 Methyl Acetate 74 1961 1967 (0546) 21873 219755 22

22 Methylene Chloride 49 1858 1864 (0517) 180593 200499 20

28 MTBE 73 2022 2022 (0562) 363998 207251 21

25 trans-12-Dichloroethene 96 1943 1949 (0540) 119022 216004 22

30 11-Dichloroethane 63 2303 2309 (0640) 238759 204130 20

36 cis-12-Dichloroethene 96 2650 2656 (0737) 126688 211021 21

10162012Page 121 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08977d Report Date 11-Oct-2012 2301

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 20020 214276 21

42 Chloroform 83 2845 2845 (0791) 215227 205163 20

44 Cyclohexane 56 2778 2784 (0773) 186275 208395 21

43 111-Trichloroethane 97 2979 2985 (0829) 195599 210453 21

45 Carbon Tetrachloride 117 2931 2937 (0815) 156464 210644 21

48 Benzene 78 3260 3260 (0469) 500200 211727 21

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 391700 477589 48

49 12-Dichloroethane 62 3412 3418 (0949) 178793 204379 20

52 Fluorobenzene 96 3595 3601 (1000) 1318918 500000

54 Trichloroethene 95 3735 3741 (1039) 127803 211922 21

56 Methyl cyclohexane 83 3723 3729 (1036) 159134 214991 21

57 12-Dichloropropane 63 4192 4199 (1166) 134808 211159 21

68 Bromodichloromethane 83 4272 4272 (1188) 171399 214054 21

67 cis-13-Dichloropropene 75 4906 4912 (0705) 217526 216258 22

70 4-Methyl-2-Pentanone 43 5631 5625 (0810) 134218 214248 21

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1312817 495616 50

66 Toluene 91 5162 5162 (0742) 572353 205343 20

64 trans-13-Dichloropropene 75 5650 5649 (0812) 195539 215018 22

69 112-Trichloroethane 83 5820 5820 (0837) 92220 217218 22

71 Tetrachloroethene 166 5582 5582 (0803) 145712 209847 21

73 2-Hexanone 43 6680 6680 (0961) 96649 200980 20

74 Dibromochloromethane 129 6015 6021 (0865) 132048 217333 22

77 12-Dibromoethane 107 6259 6265 (0900) 113742 214758 21

78 Chlorobenzene-d5 117 6954 6954 (1000) 1146590 500000

79 Chlorobenzene 112 6972 6972 (1003) 392243 206030 21

81 Ethylbenzene 106 7064 7064 (1016) 206211 205716 20

82 m+p-Xylene 106 7277 7277 (1046) 519872 407882 41

84 o-Xylene 106 7856 7862 (1130) 254939 203845 20

85 Styrene 104 7942 7942 (1142) 437977 207191 21

86 Bromoform 173 7911 7911 (1138) 93696 217219 22

88 Isopropylbenzene 105 8344 8350 (1200) 637526 207206 21

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 538047 484974 48

92 1122-Tetrachloroethane 83 9112 9112 (0871) 147339 210261 21

105 13-Dichlorobenzene 146 10325 10331 (0987) 330263 203584 20

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 683882 500000

109 14-Dichlorobenzene 146 10484 10490 (1002) 343961 204369 20

111 12-Dichlorobenzene 146 11148 11148 (1065) 320073 208797 21

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 26198 222454 22

114 124-Trichlorobenzene 180 12977 12977 (1240) 189475 219787 22

M 120 12-Dichloroethene (Total) 100 245711 427025 43

M 121 Xylene (Total) 100 774811 611727 61

10162012Page 122 of 323

Data File e08977d

Date 11-OCT-2012 2113

Client ID Instrument VOAMS5i

Sample Info LCS Operator GCMS VOAMS5

10162012Page 123 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MS

Matrix e08985dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0027

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 03071-55-6 111-Trichloroethane 103

50 1175-71-8 Dichlorodifluoromethane 865

50 05074-87-3 Chloromethane 102

50 07075-01-4 Vinyl chloride 104

50 09074-83-9 Bromomethane 107

50 2096-12-8 12-Dibromo-3-Chloropropane 121

50 1195-50-1 12-Dichlorobenzene 107

50 07575-69-4 Trichlorofluoromethane 121

50 04575-35-4 11-Dichloroethene 108

50 04578-87-5 12-Dichloropropane 111

50 04076-13-1 112-Trichloro-122-trifluoroethane

102

25 1367-64-1 Acetone 986

50 06575-15-0 Carbon disulfide 113

10 1779-20-9 Methyl acetate 100

50 09075-09-2 Methylene Chloride 106

50 065156-60-5 trans-12-Dichloroethene 106

50 10124-48-1 Chlorodibromomethane 116

50 0701634-04-4 Methyl tert-butyl ether 114

50 08575-00-3 Chloroethane 116

50 06575-34-3 11-Dichloroethane 104

50 090156-59-2 cis-12-Dichloroethene 105

25 1278-93-3 2-Butanone (MEK) 111

50 04067-66-3 Chloroform 108

50 050100-41-4 Ethylbenzene 107

50 080110-82-7 Cyclohexane 108

50 03056-23-5 Carbon tetrachloride 105

50 04071-43-2 Benzene 106

50 095107-06-2 12-Dichloroethane 107

50 04579-01-6 Trichloroethene 107

50 070108-87-2 Methylcyclohexane 115

50 06075-27-4 Dichlorobromomethane 113

50 09010061-01-5 cis-13-Dichloropropene 109

25 50108-10-1 4-Methyl-2-pentanone (MIBK) 111

50 075108-88-3 Toluene 106

50 1210061-02-6 trans-13-Dichloropropene 113

FORM I 8260B

10162012Page 124 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MS

Matrix e08985dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0027

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 09579-00-5 112-Trichloroethane 112

50 050127-18-4 Tetrachloroethene 110

25 25591-78-6 2-Hexanone 109

50 14106-93-4 12-Dibromoethane 116

50 055108-90-7 Chlorobenzene 107

15 181330-20-7 Xylenes Total 318

50 060100-42-5 Styrene 107

50 09575-25-2 Bromoform 115

50 04098-82-8 Isopropylbenzene 107

50 08079-34-5 1122-Tetrachloroethane 115

50 070541-73-1 13-Dichlorobenzene 106

50 12106-46-7 14-Dichlorobenzene 106

50 17120-82-1 124-Trichlorobenzene 110

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 125 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08985d Report Date 12-Oct-2012 0117

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08985dLab Smp Id 460-45537-C-2 MS Inj Date 12-OCT-2012 0027 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-C-2 MS5Misc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 10 QC Sample MSDil Factor 500000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 500000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 83204 173010 86

3 Chloromethane 50 1016 1016 (0283) 161645 203059 100

4 Vinyl Chloride 62 1022 1028 (0284) 141501 208792 100

6 Bromomethane 94 1181 1181 (0328) 84568 214819 110

5 Chloroethane 64 1236 1242 (0344) 73104 232055 120

7 Trichlorofluoromethane 101 1297 1303 (0361) 177163 242363 120

14 Freon TF 101 1571 1577 (0437) 100496 204542 100

15 11-Dichloroethene 96 1553 1553 (0432) 86070 216451 110

16 Acetone 58 1894 1894 (0527) 10416 197218 99

18 Carbon Disulfide 76 1565 1571 (0435) 366514 226264 110

27 Methyl Acetate 74 1961 1967 (0546) 18655 200164 100

22 Methylene Chloride 49 1857 1864 (0517) 178536 211689 100

28 MTBE 73 2016 2022 (0561) 376182 228747 110

25 trans-12-Dichloroethene 96 1949 1949 (0542) 109215 211677 100

30 11-Dichloroethane 63 2309 2309 (0642) 226749 207039 100

36 cis-12-Dichloroethene 96 2650 2656 (0737) 118569 210921 100

10162012Page 126 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08985d Report Date 12-Oct-2012 0117

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 19396 221710 110

42 Chloroform 83 2845 2845 (0791) 213034 216876 110

44 Cyclohexane 56 2784 2784 (0774) 180984 216238 110

43 111-Trichloroethane 97 2979 2985 (0829) 179996 206829 100

45 Carbon Tetrachloride 117 2930 2937 (0815) 145570 209299 100

48 Benzene 78 3260 3260 (0469) 482493 212344 110

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 369860 481613 48

49 12-Dichloroethane 62 3418 3418 (0951) 175178 213858 110

52 Fluorobenzene 96 3595 3601 (1000) 1234975 500000

54 Trichloroethene 95 3741 3741 (1041) 121196 214627 110

56 Methyl cyclohexane 83 3729 3729 (1037) 158792 229110 110

57 12-Dichloropropane 63 4192 4199 (1166) 132380 221450 110

68 Bromodichloromethane 83 4272 4272 (1188) 168703 225007 110

67 cis-13-Dichloropropene 75 4906 4912 (0705) 211819 218949 110

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 133223 221106 110

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1260222 494657 49

66 Toluene 91 5162 5162 (0742) 566751 211409 100

64 trans-13-Dichloropropene 75 5649 5649 (0812) 197737 226072 110

69 112-Trichloroethane 83 5820 5820 (0837) 91872 224994 110

71 Tetrachloroethene 166 5582 5582 (0803) 147320 220590 110

73 2-Hexanone 43 6674 6680 (0960) 100809 217957 110

74 Dibromochloromethane 129 6015 6021 (0865) 135240 231427 120

77 12-Dibromoethane 107 6259 6265 (0900) 117784 231222 120

78 Chlorobenzene-d5 117 6954 6954 (1000) 1102789 500000

79 Chlorobenzene 112 6972 6972 (1003) 391979 214069 110

81 Ethylbenzene 106 7064 7064 (1016) 207079 214786 110

82 m+p-Xylene 106 7277 7277 (1046) 521861 425705 210

84 o-Xylene 106 7856 7862 (1130) 254032 211187 100

85 Styrene 104 7942 7942 (1142) 433507 213222 110

86 Bromoform 173 7911 7911 (1138) 95433 230033 120

88 Isopropylbenzene 105 8350 8350 (1201) 635772 214844 110

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 518047 497030 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 151817 230609 120

105 13-Dichlorobenzene 146 10325 10331 (0987) 322106 211348 100

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 642491 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 334190 211356 100

111 12-Dichlorobenzene 146 11148 11148 (1065) 308704 214355 110

112 12-Dibromo-3-chloropropane 75 12233 12234 (1169) 26873 242889 120(R)

114 124-Trichlorobenzene 180 12977 12977 (1240) 177853 219597 110

M 120 12-Dichloroethene (Total) 100 227784 422599 210

M 121 Xylene (Total) 100 775893 636892 320

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 127 of 323

Data File e08985d

Date 12-OCT-2012 0027

Client ID Instrument VOAMS5i

Sample Info 460-45537-C-2 MS5 Operator GCMS VOAMS5

10162012Page 128 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MSD

Matrix e08986dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0051

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 03071-55-6 111-Trichloroethane 106

50 1175-71-8 Dichlorodifluoromethane 896

50 05074-87-3 Chloromethane 101

50 07075-01-4 Vinyl chloride 105

50 09074-83-9 Bromomethane 105

50 2096-12-8 12-Dibromo-3-Chloropropane 121

50 1195-50-1 12-Dichlorobenzene 111

50 07575-69-4 Trichlorofluoromethane 997

50 04575-35-4 11-Dichloroethene 119

50 04578-87-5 12-Dichloropropane 110

50 04076-13-1 112-Trichloro-122-trifluoroethane

111

25 1367-64-1 Acetone 101

50 06575-15-0 Carbon disulfide 119

10 1779-20-9 Methyl acetate 101

50 09075-09-2 Methylene Chloride 106

50 065156-60-5 trans-12-Dichloroethene 108

50 10124-48-1 Chlorodibromomethane 118

50 0701634-04-4 Methyl tert-butyl ether 116

50 08575-00-3 Chloroethane 105

50 06575-34-3 11-Dichloroethane 111

50 090156-59-2 cis-12-Dichloroethene 109

25 1278-93-3 2-Butanone (MEK) 114

50 04067-66-3 Chloroform 113

50 050100-41-4 Ethylbenzene 111

50 080110-82-7 Cyclohexane 117

50 03056-23-5 Carbon tetrachloride 110

50 04071-43-2 Benzene 114

50 095107-06-2 12-Dichloroethane 109

50 04579-01-6 Trichloroethene 113

50 070108-87-2 Methylcyclohexane 121

50 06075-27-4 Dichlorobromomethane 116

50 09010061-01-5 cis-13-Dichloropropene 115

25 50108-10-1 4-Methyl-2-pentanone (MIBK) 114

50 075108-88-3 Toluene 111

50 1210061-02-6 trans-13-Dichloropropene 119

FORM I 8260B

10162012Page 129 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MSD

Matrix e08986dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0051

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 09579-00-5 112-Trichloroethane 116

50 050127-18-4 Tetrachloroethene 116

25 25591-78-6 2-Hexanone 111

50 14106-93-4 12-Dibromoethane 117

50 055108-90-7 Chlorobenzene 111

15 181330-20-7 Xylenes Total 329

50 060100-42-5 Styrene 110

50 09575-25-2 Bromoform 114

50 04098-82-8 Isopropylbenzene 111

50 08079-34-5 1122-Tetrachloroethane 116

50 070541-73-1 13-Dichlorobenzene 110

50 12106-46-7 14-Dichlorobenzene 110

50 17120-82-1 124-Trichlorobenzene 119

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

97 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 130 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08986d Report Date 12-Oct-2012 0118

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08986dLab Smp Id 460-45537-C-2 MSD Inj Date 12-OCT-2012 0051 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-C-2 MSD5Misc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 11 QC Sample MSDDil Factor 500000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 500000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 90471 179208 90

3 Chloromethane 50 1016 1016 (0283) 169425 202751 100

4 Vinyl Chloride 62 1022 1028 (0284) 149176 209689 100

6 Bromomethane 94 1181 1181 (0328) 86595 209548 100

5 Chloroethane 64 1236 1242 (0344) 69668 210673 100

7 Trichlorofluoromethane 101 1297 1303 (0361) 152935 199307 100

14 Freon TF 101 1565 1577 (0435) 114134 221294 110

15 11-Dichloroethene 96 1547 1553 (0430) 98966 237094 120

16 Acetone 58 1900 1894 (0529) 11165 201386 100

18 Carbon Disulfide 76 1565 1571 (0435) 405349 238385 120

27 Methyl Acetate 74 1961 1967 (0546) 19684 201192 100

22 Methylene Chloride 49 1858 1864 (0517) 187993 212342 110

28 MTBE 73 2022 2022 (0562) 399850 231621 120(R)

25 trans-12-Dichloroethene 96 1943 1949 (0540) 117162 216323 110

30 11-Dichloroethane 63 2309 2309 (0642) 255983 222660 110

36 cis-12-Dichloroethene 96 2650 2656 (0737) 129220 218978 110

10162012Page 131 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08986d Report Date 12-Oct-2012 0118

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 20938 227991 110

42 Chloroform 83 2845 2845 (0791) 233404 226357 110

44 Cyclohexane 56 2778 2784 (0773) 204751 233046 120

43 111-Trichloroethane 97 2979 2985 (0829) 194508 212915 110

45 Carbon Tetrachloride 117 2931 2937 (0815) 161111 220670 110

48 Benzene 78 3260 3260 (0469) 525066 227601 110

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 386156 479012 48

49 12-Dichloroethane 62 3412 3418 (0949) 188223 218898 110

52 Fluorobenzene 96 3595 3601 (1000) 1296388 500000

54 Trichloroethene 95 3741 3741 (1041) 133629 225434 110

56 Methyl cyclohexane 83 3723 3729 (1036) 175741 241553 120

57 12-Dichloropropane 63 4192 4199 (1166) 138376 220515 110

68 Bromodichloromethane 83 4272 4272 (1188) 182026 231276 120

67 cis-13-Dichloropropene 75 4906 4912 (0705) 226245 230339 120

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 139423 227913 110

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1279885 494812 49

66 Toluene 91 5162 5162 (0742) 602122 221221 110

64 trans-13-Dichloropropene 75 5650 5649 (0812) 211878 238592 120(R)

69 112-Trichloroethane 83 5820 5820 (0837) 95786 231047 120

71 Tetrachloroethene 166 5582 5582 (0803) 157152 231769 120

73 2-Hexanone 43 6680 6680 (0961) 103997 221464 110

74 Dibromochloromethane 129 6015 6021 (0865) 140562 236912 120

77 12-Dibromoethane 107 6259 6265 (0900) 120913 233791 120

78 Chlorobenzene-d5 117 6954 6954 (1000) 1119645 500000

79 Chlorobenzene 112 6972 6972 (1003) 411739 221475 110

81 Ethylbenzene 106 7064 7064 (1016) 216984 221672 110

82 m+p-Xylene 106 7277 7277 (1046) 549474 441482 220

84 o-Xylene 106 7856 7862 (1130) 265488 217389 110

85 Styrene 104 7942 7942 (1142) 452927 219420 110

86 Bromoform 173 7911 7911 (1138) 96039 228008 110

88 Isopropylbenzene 105 8344 8350 (1200) 668990 222665 110

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 517679 487311 49

92 1122-Tetrachloroethane 83 9112 9112 (0871) 155509 231763 120

105 13-Dichlorobenzene 146 10325 10331 (0987) 342279 220349 110

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 654839 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 355256 220442 110

111 12-Dichlorobenzene 146 11148 11148 (1065) 324646 221173 110

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 27355 242581 120(R)

114 124-Trichlorobenzene 180 12977 12977 (1240) 196651 238228 120

M 120 12-Dichloroethene (Total) 100 246382 435302 220

M 121 Xylene (Total) 100 814963 658871 330

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 132 of 323

Data File e08986d

Date 12-OCT-2012 0051

Client ID Instrument VOAMS5i

Sample Info 460-45537-C-2 MSD5 Operator GCMS VOAMS5

10162012Page 133 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GCMS VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

VOAMS5

128076

Start Date

End Date 09172012 1616

09172012 0324

BFB 460-1280761 Rtx-VMS 018(mm)109172012 0324 e07834d

IC 460-1280762 Rtx-VMS 018(mm)109172012 0449 e07836d

IC 460-1280763 Rtx-VMS 018(mm)109172012 0536 e07838d

ICIS 460-1280764 Rtx-VMS 018(mm)109172012 0600 e07839d

IC 460-1280765 Rtx-VMS 018(mm)109172012 0623 e07840d

IC 460-1280766 Rtx-VMS 018(mm)109172012 0646 e07841d

IC 460-1280767 Rtx-VMS 018(mm)109172012 0710 e07842d

ZZZZZ Rtx-VMS 018(mm)109172012 0937

ZZZZZ Rtx-VMS 018(mm)109172012 1047

ZZZZZ Rtx-VMS 018(mm)109172012 1111

ZZZZZ Rtx-VMS 018(mm)109172012 1134

ZZZZZ Rtx-VMS 018(mm)109172012 1157

ZZZZZ Rtx-VMS 018(mm)509172012 1221

ZZZZZ Rtx-VMS 018(mm)509172012 1244

ZZZZZ Rtx-VMS 018(mm)109172012 1307

ZZZZZ Rtx-VMS 018(mm)109172012 1331

ZZZZZ Rtx-VMS 018(mm)109172012 1354

ZZZZZ Rtx-VMS 018(mm)109172012 1417

ZZZZZ Rtx-VMS 018(mm)109172012 1441

CCV 460-12807620 Rtx-VMS 018(mm)109172012 1616

8260B

10162012Page 134 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GCMS VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

VOAMS5

131656

Start Date

End Date 10122012 0114

10112012 2008

BFB 460-1316561 Rtx-VMS 018(mm)110112012 2008 e08975d

CCVIS 460-1316562 Rtx-VMS 018(mm)110112012 2050 e08976d

LCS 460-1316563 Rtx-VMS 018(mm)110112012 2113 e08977d

MB 460-1316564 Rtx-VMS 018(mm)110112012 2247 e08981d

460-45537-3 TB-17338-100512-253 Rtx-VMS 018(mm)110112012 2317 e08982d

460-45537-1 WC-17338-100512-MW14-MM-251

Rtx-VMS 018(mm)110112012 2341 e08983d

460-45537-2 WC-17338-100512-MW101-MM-252

Rtx-VMS 018(mm)110122012 0004 e08984d

460-45537-2 MS WC-17338-100512-MW101-MM-252 MS

Rtx-VMS 018(mm)510122012 0027 e08985d

460-45537-2 MSD WC-17338-100512-MW101-MM-252 MSD

Rtx-VMS 018(mm)510122012 0051 e08986d

CCV 460-13165610 Rtx-VMS 018(mm)110122012 0114 e08987d

8260B

10162012Page 135 of 323

10162012Page 136 of 323

10162012Page 137 of 323

10162012Page 138 of 323

10162012Page 139 of 323

Method 8082 -

DelawarePolychlorinated Biphenyls (PCBs)

(GC) by Method 8082 (Delaware)

10162012Page 140 of 323

FORM II

GC SEMI VOA SURROGATE RECOVERY

Lab Name Job No 460-45537-1

SDG No

Matrix Water Level Low

TestAmerica Edison

GC Column (1) ID (mm) GC Column (2) ID (mm)CLP-1 053 CLP-2 053

Lab Sample IDClient Sample ID DCB1 DCB2

460-45537-1WC-17338-100512-MW14-MM-251

82 83

460-45537-2WC-17338-100512-MW101-MM-252

52 50

MB 460-1309971-A

97 88

LCS 460-1309972-A

91 84

LCSD 460-1309973-A

108 99

QC LIMITSQC LIMITSDCB = DCB Decachlorobiphenyl 37-150

FORM II 8082

Column to be used to flag recovery values

10162012Page 141 of 323

GC SEMI VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vf479497dWater

Lab ID LCS 460-1309972-A Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

PCB-1016 500 507 71-126101

PCB-1260 500 557 73-130111

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 142 of 323

GC SEMI VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vr479497dWater

Lab ID LCS 460-1309972-A Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

PCB-1016 500 483 71-12697

PCB-1260 500 573 73-130115

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 143 of 323

GC SEMI VOA LAB CONTROL SAMPLE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vf479498dWater

Lab ID LCSD 460-1309973-A Client ID

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

LCSD LCSD

500 516 30 71-126PCB-1016 2103

500 583 30 73-130PCB-1260 5117

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 144 of 323

GC SEMI VOA LAB CONTROL SAMPLE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vr479498dWater

Lab ID LCSD 460-1309973-A Client ID

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

LCSD LCSD

500 497 30 71-126PCB-1016 399

500 595 30 73-130PCB-1260 4119

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 145 of 323

FORM IV

GC SEMI VOA METHOD BLANK SUMMARY

Lab Name

SDG No

Job No 460-45537-1TestAmerica Edison

Date Analyzed(1)

Instrument ID(1)

GC Column(1) ID

Instrument ID(2)

Date Extracted 10082012 0755

Date Analyzed(2)

GC Column(2) IDCLP-2053(mm) 053(mm)

PESTGC9

10082012 2208

Lab File ID(1) Lab File ID(2)

Matrix Water

vf479496d

Lab Sample ID MB 460-1309971-A

vr479496d

10082012 2208

PESTGC9

CLP-1

THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES

ANALYZED 2

DATEDATE

ANALYZED 1LAB SAMPLE IDCLIENT SAMPLE ID

LCS 460-1309972-A 10082012 2224 10082012 2224

LCSD 460-1309973-A 10082012 2239 10082012 2239

460-45537-1WC-17338-100512-MW14-MM-251

10092012 0029 10092012 0029

460-45537-2WC-17338-100512-MW101-MM-252

10092012 0045 10092012 0045

FORM IV 8082

10162012Page 146 of 323

GC SEMI VOA ANALYTICAL SEQUENCE

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVRT 460-1311372 Date Analyzed 10082012 1830

Lab File ID (Standard) vf479493d

Instrument ID PESTGC9 GC Column CLP-2 ID 053(mm)

Heated Purge (YN) N

Calibration ID 17840

THE ANALYTICAL SEQUENCE OF BLANKS SAMPLES STANDARDS MSMSDs AND LCSs IS GIVEN BELOW

RT

DCB

UPPER LIMIT

LOWER LIMIT

1159

1139

CONTINUING CALIBRATION SURROGATE 1149

LAB SAMPLE ID DATE ANALYZEDCLIENT SAMPLE ID LAB FILE ID

CCVRT 460-1311372 10082012 1830 1149vf479493d

MB 460-1309971-A 10082012 2208 1148vf479496d

LCS 460-1309972-A 10082012 2224 1148vf479497d

LCSD 460-1309973-A 10082012 2239 1148vf479498d

460-45537-1 10092012 0029 1149WC-17338-100512-MW14-MM-251

vf479505d

460-45537-2 10092012 0045 1149WC-17338-100512-MW101-MM-252

vf479506d

PIBLK 460-13113718 10092012 0131 1149vf479509d

CCV 460-13113719 10092012 0147 1149vf479510d

DCB = DCB Decachlorobiphenyl

DCB RT Limit = plusmn 01 minutes of surrogate RT

Column used to flag values outside QC limits

FORM VIII 8082

10162012Page 147 of 323

GC SEMI VOA ANALYTICAL SEQUENCE

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVRT 460-1311372 Date Analyzed 10082012 1830

Lab File ID (Standard) vr479493d

Instrument ID PESTGC9 GC Column CLP-1 ID 053(mm)

Heated Purge (YN) N

Calibration ID 17839

THE ANALYTICAL SEQUENCE OF BLANKS SAMPLES STANDARDS MSMSDs AND LCSs IS GIVEN BELOW

RT

DCB

UPPER LIMIT

LOWER LIMIT

1071

1051

CONTINUING CALIBRATION SURROGATE 1061

LAB SAMPLE ID DATE ANALYZEDCLIENT SAMPLE ID LAB FILE ID

CCVRT 460-1311372 10082012 1830 1061vr479493d

MB 460-1309971-A 10082012 2208 1061vr479496d

LCS 460-1309972-A 10082012 2224 1061vr479497d

LCSD 460-1309973-A 10082012 2239 1061vr479498d

460-45537-1 10092012 0029 1061WC-17338-100512-MW14-MM-251

vr479505d

460-45537-2 10092012 0045 1061WC-17338-100512-MW101-MM-252

vr479506d

PIBLK 460-13113718 10092012 0131 1061vr479509d

CCV 460-13113719 10092012 0147 1061vr479510d

DCB = DCB Decachlorobiphenyl

DCB RT Limit = plusmn 01 minutes of surrogate RT

Column used to flag values outside QC limits

FORM VIII 8082

10162012Page 148 of 323

FORM XForm 1

Client Sample ID

Lab Name Job No

SDG No

Lab Sample ID LCS 460-1309972-A

Instrument ID (1) Instrument ID (2)

Date Analyzed (1) Date Analyzed (2)

GC Column (1) ID GC Column (2) ID

TestAmerica Edison 460-45537-1

IDENTIFICATION SUMMARYForm 1

053(mm) 053(mm)

10082012 2224 10082012 2224

PESTGC9 PESTGC9

CLP-1 CLP-2

ANALYTE COL PEAK RTRT WINDOW

FROM TO PEAK MEAN

CONCENTRATIONRPD

PCB-1016 1 1 206 201 215 473 483 47

2 250 246 260 494

3 275 271 285 530

4 310 306 320 501

5 330 326 340 520

6 369 361 375 302

7 401 397 411 541

8 419 412 426 505

2 1 293 289 303 525 507

2 360 357 371 562

3 404 401 415 567

4 444 441 455 558

5 468 465 479 594

6 518 509 523 402

7 557 547 561 259

8 571 568 582 584

PCB-1260 1 1 605 600 614 554 573 28

2 650 645 659 558

3 694 689 703 581

4 714 709 723 548

5 758 753 767 565

6 886 882 896 559

7 908 904 918 619

8 1014 1008 1022 600

2 1 771 769 783 600 557

2 817 814 828 594

3 903 901 915 625

4 928 926 940 622

5 941 938 952 643

6 986 983 997 612

7 1062 1055 1069 212

8 1106 1102 1116 550

FORM X 8082

10162012Page 149 of 323

FORM XForm 1

Client Sample ID

Lab Name Job No

SDG No

Lab Sample ID LCSD 460-1309973-A

Instrument ID (1) Instrument ID (2)

Date Analyzed (1) Date Analyzed (2)

GC Column (1) ID GC Column (2) ID

TestAmerica Edison 460-45537-1

IDENTIFICATION SUMMARYForm 1

053(mm) 053(mm)

10082012 2239 10082012 2239

PESTGC9 PESTGC9

CLP-1 CLP-2

ANALYTE COL PEAK RTRT WINDOW

FROM TO PEAK MEAN

CONCENTRATIONRPD

PCB-1016 1 1 206 201 215 483 497 38

2 250 246 260 505

3 275 271 285 542

4 310 306 320 510

5 330 326 340 529

6 368 361 375 369

7 401 397 411 549

8 419 412 426 491

2 1 292 289 303 535 516

2 359 357 371 574

3 404 401 415 572

4 443 441 455 572

5 468 465 479 606

6 518 509 523 407

7 557 547 561 267

8 571 568 582 599

PCB-1260 1 1 605 600 614 565 595 19

2 650 645 659 571

3 694 689 703 595

4 714 709 723 563

5 757 753 767 585

6 886 882 896 582

7 908 904 918 656

8 1014 1008 1022 639

2 1 771 769 783 615 583

2 816 814 828 610

3 902 901 915 645

4 928 926 940 648

5 940 938 952 669

6 986 983 997 637

7 1062 1055 1069 253

8 1106 1102 1116 590

FORM X 8082

10162012Page 150 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix vf479505dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1000

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0029

5(mL)

Sample wtvol 980(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

83 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 151 of 323

Data File vf479505d Report Date 09-Oct-2012 0313

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479505dLab Smp Id 460-45537-E-1-B Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0029 Operator Inst ID PESTGC9iSmp Info 460-45537-E-1-BMisc Info 460-45537-E-1-BComment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 35 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 98000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11489 11515 -0026 22061081 829479 042 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 152 of 323

Data File vf479505d

Date 09-OCT-2012 0029

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-1-B Operator

10162012Page 153 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix vr479505dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1000

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0029

5(mL)

Sample wtvol 980(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

051 013U12674-11-2 PCB-1016 013

051 029U11104-28-2 PCB-1221 029

051 012U11141-16-5 PCB-1232 012

051 012U53469-21-9 PCB-1242 012

051 024U12672-29-6 PCB-1248 024

051 017U11097-69-1 PCB-1254 017

051 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

82 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 154 of 323

Data File vr479505d Report Date 09-Oct-2012 0303

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479505dLab Smp Id 460-45537-E-1-B Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0029 Operator Inst ID PESTGC9iSmp Info 460-45537-E-1-BMisc Info 460-45537-E-1-BComment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 35 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 98000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 38407031 815954 042 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 155 of 323

Data File vr479505d

Date 09-OCT-2012 0029

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-1-B Operator

10162012Page 156 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix vf479506dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1230

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0045

5(mL)

Sample wtvol 990(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

50 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 157 of 323

Data File vf479506d Report Date 09-Oct-2012 0322

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479506dLab Smp Id 460-45537-E-2-A Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0045 Operator Inst ID PESTGC9iSmp Info 460-45537-E-2-AMisc Info 460-45537-E-2-AComment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 36 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 99000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11487 11515 -0028 13346591 501821 025 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 158 of 323

Data File vf479506d

Date 09-OCT-2012 0045

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-2-A Operator

10162012Page 159 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix vr479506dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1230

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0045

5(mL)

Sample wtvol 990(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

051 013U12674-11-2 PCB-1016 013

051 028U11104-28-2 PCB-1221 028

051 012U11141-16-5 PCB-1232 012

051 012U53469-21-9 PCB-1242 012

051 024U12672-29-6 PCB-1248 024

051 017U11097-69-1 PCB-1254 017

051 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

52 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 160 of 323

Data File vr479506d Page 1 Report Date 09-Oct-2012 0322

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479506dLab Smp Id 460-45537-E-2-A Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0045 Operator Inst ID PESTGC9iSmp Info 460-45537-E-2-AMisc Info 460-45537-E-2-AComment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 36 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 99000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 24675227 524223 026 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 161 of 323

Data File vr479506d

Date 09-OCT-2012 0045

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-2-A Operator

10162012Page 162 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vf479200dLevel 2 IC 460-1299268 vf479201dLevel 3 IC 460-1299269 vf479202dLevel 4 IC 460-12992610 vf479203dLevel 5 IC 460-12992611 vf479204d

ANALYTE LVL 1 LVL 2 LVL 3 LVL 4 LVL 5 AVG RTRT WINDOW

PCB-1016 Peak 1 29602891 - 30312960 2960 2961 2959 2959PCB-1016 Peak 2 36403571 - 37113640 3640 3641 3639 3640PCB-1016 Peak 3 40844015 - 41554084 4084 4085 4083 4083PCB-1016 Peak 4 44774409 - 45494477 4477 4479 4477 4476PCB-1016 Peak 5 47224652 - 47924722 4722 4722 4722 4722PCB-1016 Peak 6 51575088 - 52285157 5158 5158 5157 5157PCB-1016 Peak 7 55425472 - 56125542 5543 5542 5542 5542PCB-1016 Peak 8 57515682 - 58225751 5751 5752 5751 5751PCB-1260 Peak 1 77567686 - 78267756 7756 7756 7756 7755PCB-1260 Peak 2 82158145 - 82858216 8215 8215 8215 8215PCB-1260 Peak 3 90839014 - 91549084 9084 9084 9083 9082PCB-1260 Peak 4 93329262 - 94029332 9332 9332 9332 9331PCB-1260 Peak 5 94549384 - 95249454 9454 9454 9454 9453PCB-1260 Peak 6 99019831 - 99719901 9901 9901 9901 9901PCB-1260 Peak 7 1061710546 - 1068610617 10617 10616 10617 10616PCB-1260 Peak 8 1108611016 - 1115611087 11087 11086 11084 11085DCB Decachlorobiphenyl 1151511415 - 1161511518 11520 11515 11510 11512

FORM VI 8082 10162012Page 163 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1299267 vf479200d2Level IC 460-1299268 vf479201d3Level IC 460-1299269 vf479202d4Level IC 460-12992610 vf479203d5Level IC 460-12992611 vf479204d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1016 Peak 1 Ave 155 20012858 10484 96475 9762186122

102726535

PCB-1016 Peak 2 Ave 122 20025248 21181 20808 2014318185

211130015

PCB-1016 Peak 3 Ave 124 20010359 90007 83526 8441074163

871400841

PCB-1016 Peak 4 Ave 130 20045579 38951 35291 3591632814

377100165

PCB-1016 Peak 5 Ave 129 20019485 17677 14821 1595214340

164548979

PCB-1016 Peak 6 Ave 171 20012410 10306 89543 9039281426

977025128

PCB-1016 Peak 7 Ave 161 20015097 12427 11165 1121510046

119900052

PCB-1016 Peak 8 Ave 121 20014456 12522 11609 1161310532

121463746

PCB-1260 Peak 1 Ave 165 20028165 22320 20852 2059718598

221063931

PCB-1260 Peak 2 Ave 173 20032398 25230 23518 2315121164

250922627

PCB-1260 Peak 3 Ave 101 20042792 37584 35706 3549332757

368665853

PCB-1260 Peak 4 Ave 114 20019125 16727 15681 1547514194

162405856

PCB-1260 Peak 5 Ave 71 20097407 90339 86445 8609680436

881445133

PCB-1260 Peak 6 Ave 116 20020218 16837 16387 1620514980

169255417

PCB-1260 Peak 7 Ave 115 20025044 20516 20530 2080218426

210635761

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 164 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1260 Peak 8 Ave 114 20092729 80982 75320 7482969000

785718832

DCB Decachlorobiphenyl Ave 104 200306013 281530 257456 246481238335

265963086

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 165 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vf479200dLevel 2 IC 460-1299268 vf479201dLevel 3 IC 460-1299269 vf479202dLevel 4 IC 460-12992610 vf479203dLevel 5 IC 460-12992611 vf479204d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1LVL 2 LVL 2LVL 3 LVL 3LVL 4 LVL 4LVL 5 LVL 5

PCB-1016 Peak 1 Ave 1285777 5241842 9647477 14643185 21530533 100 500 1000 1500 2500PCB-1016 Peak 2 Ave 2524804 10590544 20808307 30213965 45462323 100 500 1000 1500 2500PCB-1016 Peak 3 Ave 1035943 4500373 8352607 12661468 18540701 100 500 1000 1500 2500PCB-1016 Peak 4 Ave 4557926 19475271 35290615 53874092 82034010 100 500 1000 1500 2500PCB-1016 Peak 5 Ave 1948484 8838480 14821328 23927783 35848765 100 500 1000 1500 2500PCB-1016 Peak 6 Ave 1240957 5152808 8954270 13558761 20356566 100 500 1000 1500 2500PCB-1016 Peak 7 Ave 1509707 6213265 11165134 16822458 25115800 100 500 1000 1500 2500PCB-1016 Peak 8 Ave 1445572 6260864 11609452 17418946 26330856 100 500 1000 1500 2500PCB-1260 Peak 1 Ave 2816529 11159859 20851674 30895442 46495806 100 500 1000 1500 2500PCB-1260 Peak 2 Ave 3239811 12615093 23518487 34726449 52908911 100 500 1000 1500 2500PCB-1260 Peak 3 Ave 4279245 18792136 35705636 53240044 81893015 100 500 1000 1500 2500PCB-1260 Peak 4 Ave 1912505 8363664 15681452 23213228 35484032 100 500 1000 1500 2500PCB-1260 Peak 5 Ave 974074 4516956 8644462 12914338 20108960 100 500 1000 1500 2500PCB-1260 Peak 6 Ave 2021814 8418625 16386843 24307809 37450674 100 500 1000 1500 2500PCB-1260 Peak 7 Ave 2504445 10257895 20530020 31202581 46064749 100 500 1000 1500 2500PCB-1260 Peak 8 Ave 927285 4049088 7531982 11224374 17250044 100 500 1000 1500 2500DCB Decachlorobiphenyl Ave 7650320 14076513 25745578 36972164 47667099 250 500 100 150 200

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 166 of 323

Data File vf479200d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479200dLab Smp Id IC-SG1660L1_00013 Inj Date 30-SEP-2012 1704 Operator Inst ID PESTGC9iSmp Info ic-SG1660L1_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1704 Cal File vf479200dAls bottle 7 Calibration Sample Level 1Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2960 2961 -0001 1285777 100000 120 8000- 12000 10000

3640 3641 -0001 2524804 100000 120 15709- 23564 19636

4084 4085 -0001 1035943 100000 120 6446- 9668 8057

4477 4479 -0002 4557926 100000 120 28359- 42539 35449

4722 4722 0000 1948484 100000 120 12123- 18185 15154

5157 5158 -0001 1240957 100000 130 7721- 11582 9651

5542 5542 0000 1509707 100000 120 9393- 14090 11742

5751 5752 -0001 1445572 100000 120 8994- 13491 11243

Average of Peak Amounts = 122

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 2816529 100000 130 8000- 12000 10000(M)

10162012Page 167 of 323

Data File vf479200d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8216 8215 0001 3239811 100000 130 9202- 13803 11503

9084 9084 0000 4279245 100000 120 12155- 18232 15193

9332 9332 0000 1912505 100000 120 5432- 8148 6790

9454 9454 0000 974074 100000 110 2767- 4150 3458

9901 9901 0000 2021814 100000 120 5743- 8614 7178

10617 10616 0001 2504445 100000 120 7114- 10670 8892

11087 11086 0001 927285 100000 120 2634- 3951 3292

Average of Peak Amounts = 120

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11518 11515 0003 7650320 250000 29 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 168 of 323

Data File vf479200d

Date 30-SEP-2012 1704

Client ID Instrument PESTGC9i

Sample Info ic-SG1660L1_00013 Operator

10162012Page 169 of 323

Data File vf479201d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479201dLab Smp Id IC-SG1660L2_00013 Inj Date 30-SEP-2012 1720 Operator Inst ID PESTGC9iSmp Info SG1660L2_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1720 Cal File vf479201dAls bottle 8 Calibration Sample Level 2Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2960 2961 -0001 5241842 500000 510 8000- 12000 10000

3640 3641 -0001 10590544 500000 500 16163- 24245 20204

4084 4085 -0001 4500373 500000 520 6868- 10303 8585

4477 4479 -0002 19475271 500000 520 29723- 44584 37153

4722 4722 0000 8838480 500000 540 13489- 20234 16861

5158 5158 0000 5152808 500000 530 7864- 11796 9830

5543 5542 0001 6213265 500000 520 9483- 14224 11853

5751 5752 -0001 6260864 500000 520 9555- 14333 11944

Average of Peak Amounts = 518

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 11159859 500000 500 8000- 12000 10000(M)

10162012Page 170 of 323

Data File vf479201d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 12615093 500000 500 9043- 13565 11304

9084 9084 0000 18792136 500000 510 13471- 20207 16839

9332 9332 0000 8363664 500000 510 5996- 8993 7494

9454 9454 0000 4516956 500000 510 3238- 4857 4048

9901 9901 0000 8418625 500000 500 6035- 9052 7544

10617 10616 0001 10257895 500000 490 7353- 11030 9192

11087 11086 0001 4049088 500000 520 2903- 4354 3628

Average of Peak Amounts = 506

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11520 11515 0005 14076513 500000 53 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 171 of 323

Data File vf479201d

Date 30-SEP-2012 1720

Client ID Instrument PESTGC9i

Sample Info SG1660L2_00013 Operator

10162012Page 172 of 323

Data File vf479202d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479202dLab Smp Id IC-SG1660L3_00019 Inj Date 30-SEP-2012 1735 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 9 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2961 2961 0000 9647477 100000 940 8000- 12000 10000

3641 3641 0000 20808307 100000 980 17255- 25882 21569

4085 4085 0000 8352607 100000 960 6926- 10389 8658

4479 4479 0000 35290615 100000 940 29264- 43896 36580

4722 4722 0000 14821328 100000 900 12290- 18435 15363

5158 5158 0000 8954270 100000 920 7425- 11138 9281

5542 5542 0000 11165134 100000 930 9258- 13888 11573

5752 5752 0000 11609452 100000 960 9627- 14440 12034

Average of Peak Amounts = 940

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 20851674 100000 940 8000- 12000 10000(M)

10162012Page 173 of 323

Data File vf479202d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 23518487 100000 940 9023- 13535 11279

9084 9084 0000 35705636 100000 970 13699- 20548 17124

9332 9332 0000 15681452 100000 960 6016- 9025 7520

9454 9454 0000 8644462 100000 980 3317- 4975 4146

9901 9901 0000 16386843 100000 970 6287- 9431 7859

10616 10616 0000 20530020 100000 970 7877- 11815 9846

11086 11086 0000 7531982 100000 960 2890- 4335 3612

Average of Peak Amounts = 962

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11515 11515 0000 25745578 100000 97 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 174 of 323

Data File vf479202d

Date 30-SEP-2012 1735

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 175 of 323

Data File vf479203d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479203dLab Smp Id IC-SG1660L4_00013 Inj Date 30-SEP-2012 1751 Operator Inst ID PESTGC9iSmp Info SG1660L4_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1751 Cal File vf479203dAls bottle 10 Calibration Sample Level 4Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2959 2961 -0002 14643185 150000 1400 8000- 12000 10000

3639 3641 -0002 30213965 150000 1400 16507- 24760 20633

4083 4085 -0002 12661468 150000 1400 6917- 10376 8647

4477 4479 -0002 53874092 150000 1400 29433- 44149 36791

4722 4722 0000 23927783 150000 1400 13072- 19609 16341

5157 5158 -0001 13558761 150000 1400 7408- 11111 9259

5542 5542 0000 16822458 150000 1400 9191- 13786 11488

5751 5752 -0001 17418946 150000 1400 9516- 14275 11896

Average of Peak Amounts = 143e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 30895442 150000 1400 8000- 12000 10000(M)

10162012Page 176 of 323

Data File vf479203d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 34726449 150000 1400 8992- 13488 11240

9083 9084 -0001 53240044 150000 1400 13786- 20679 17232

9332 9332 0000 23213228 150000 1400 6011- 9016 7513

9454 9454 0000 12914338 150000 1500 3344- 5016 4180

9901 9901 0000 24307809 150000 1400 6294- 9441 7868

10617 10616 0001 31202581 150000 1500 8080- 12119 10099

11084 11086 -0002 11224374 150000 1400 2906- 4360 3633

Average of Peak Amounts = 143e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11510 11515 -0005 36972164 150000 140 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 177 of 323

Data File vf479203d

Date 30-SEP-2012 1751

Client ID Instrument PESTGC9i

Sample Info SG1660L4_00013 Operator

10162012Page 178 of 323

Data File vf479204d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479204dLab Smp Id IC-SG1660L5_00013 Inj Date 30-SEP-2012 1807 Operator Inst ID PESTGC9iSmp Info SG1660L5_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1807 Cal File vf479204dAls bottle 11 Calibration Sample Level 5Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2959 2961 -0002 21530533 250000 2100 8000- 12000 10000

3640 3641 -0001 45462323 250000 2200 16892- 25338 21115

4083 4085 -0002 18540701 250000 2100 6889- 10334 8611

4476 4479 -0003 82034010 250000 2200 30481- 45721 38101

4722 4722 0000 35848765 250000 2200 13320- 19980 16650

5157 5158 -0001 20356566 250000 2100 7564- 11346 9455

5542 5542 0000 25115800 250000 2100 9332- 13998 11665

5751 5752 -0001 26330856 250000 2200 9784- 14675 12230

Average of Peak Amounts = 213e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7755 7756 -0001 46495806 250000 2100 8000- 12000 10000(M)

10162012Page 179 of 323

Data File vf479204d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 52908911 250000 2100 9103- 13655 11379

9082 9084 -0002 81893015 250000 2200 14090- 21136 17613

9331 9332 -0001 35484032 250000 2200 6105- 9158 7632

9453 9454 -0001 20108960 250000 2300 3460- 5190 4325

9901 9901 0000 37450674 250000 2200 6444- 9666 8055

10616 10616 0000 46064749 250000 2200 7926- 11889 9907

11085 11086 -0001 17250044 250000 2200 2968- 4452 3710

Average of Peak Amounts = 219e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11512 11515 -0003 47667099 200000 180 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 180 of 323

Data File vf479204d

Date 30-SEP-2012 1807

Client ID Instrument PESTGC9i

Sample Info SG1660L5_00013 Operator

10162012Page 181 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vr479200dLevel 2 IC 460-1299268 vr479201dLevel 3 IC 460-1299269 vr479202dLevel 4 IC 460-12992610 vr479203dLevel 5 IC 460-12992611 vr479204d

ANALYTE LVL 1 LVL 2 LVL 3 LVL 4 LVL 5 AVG RTRT WINDOW

PCB-1016 Peak 1 20842015 - 21552085 2084 2085 2083 2084PCB-1016 Peak 2 25272457 - 25972527 2526 2527 2527 2526PCB-1016 Peak 3 27762707 - 28472777 2776 2777 2775 2775PCB-1016 Peak 4 31283060 - 32003128 3128 3130 3128 3127PCB-1016 Peak 5 33293260 - 34003329 3329 3330 3328 3328PCB-1016 Peak 6 36823615 - 37553682 3682 3685 3683 3681PCB-1016 Peak 7 40433973 - 41134042 4043 4043 4042 4043PCB-1016 Peak 8 41904121 - 42614190 4190 4191 4188 4190PCB-1260 Peak 1 60716002 - 61426072 6072 6072 6071 6071PCB-1260 Peak 2 65226452 - 65926522 6523 6522 6522 6521PCB-1260 Peak 3 69646894 - 70346964 6965 6964 6963 6964PCB-1260 Peak 4 71647095 - 72357165 7165 7165 7164 7164PCB-1260 Peak 5 76027532 - 76727602 7603 7602 7602 7601PCB-1260 Peak 6 88938823 - 89638893 8894 8893 8893 8892PCB-1260 Peak 7 91159045 - 91859115 9115 9115 9115 9114PCB-1260 Peak 8 1015310083 - 1022310153 10154 10153 10153 10153DCB Decachlorobiphenyl 1062410524 - 1072410625 10625 10624 10624 10624

FORM VI 8082 10162012Page 182 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1299267 vr479200d2Level IC 460-1299268 vr479201d3Level IC 460-1299269 vr479202d4Level IC 460-12992610 vr479203d5Level IC 460-12992611 vr479204d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1016 Peak 1 Ave 197 20021391 15827 14690 1421213626

159493236

PCB-1016 Peak 2 Ave 165 20034434 28377 25503 2514722693

272309984

PCB-1016 Peak 3 Ave 77 20020149 18502 16986 1713716990

179529604

PCB-1016 Peak 4 Ave 163 20075334 61344 55787 5498850020

594947119

PCB-1016 Peak 5 Ave 111 20026774 23733 21963 2197020028

228936643

PCB-1016 Peak 6 Ave 186 20030865 24479 22517 2109919526

236972316

PCB-1016 Peak 7 Ave 97 20025842 23012 21540 2153920131

224127747

PCB-1016 Peak 8 Ave 151 20012619 94689 86303 1057294995

101578271

PCB-1260 Peak 1 Ave 163 20041532 33110 31025 3015327565

326771001

PCB-1260 Peak 2 Ave 177 20078411 60909 57128 5539650491

604671657

PCB-1260 Peak 3 Ave 138 20068452 55082 53236 5187948612

554520757

PCB-1260 Peak 4 Ave 154 20037971 30462 28586 2772626073

301638112

PCB-1260 Peak 5 Ave 148 20034082 26592 25567 2477624302

270637128

PCB-1260 Peak 6 Ave 81 20038982 34673 33173 3331131697

343672090

PCB-1260 Peak 7 Ave 66 20023297 21847 20031 2012320512

211620048

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 183 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1260 Peak 8 Ave 59 20018824 17382 16914 1709216013

172450198

DCB Decachlorobiphenyl Ave 109 200544588 499440 455074 438703415700

470701073

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 184 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vr479200dLevel 2 IC 460-1299268 vr479201dLevel 3 IC 460-1299269 vr479202dLevel 4 IC 460-12992610 vr479203dLevel 5 IC 460-12992611 vr479204d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1LVL 2 LVL 2LVL 3 LVL 3LVL 4 LVL 4LVL 5 LVL 5

PCB-1016 Peak 1 Ave 2139086 7913738 14690255 21317999 34065069 100 500 1000 1500 2500PCB-1016 Peak 2 Ave 3443416 14188692 25503333 37720095 56733462 100 500 1000 1500 2500PCB-1016 Peak 3 Ave 2014938 9251204 16986172 25705034 42475382 100 500 1000 1500 2500PCB-1016 Peak 4 Ave 7533379 30672168 55786970 82482485 125050351 100 500 1000 1500 2500PCB-1016 Peak 5 Ave 2677413 11866731 21962918 32955239 50069130 100 500 1000 1500 2500PCB-1016 Peak 6 Ave 3086462 12239557 22517485 31648230 48815297 100 500 1000 1500 2500PCB-1016 Peak 7 Ave 2584175 11505820 21540272 32309208 50326849 100 500 1000 1500 2500PCB-1016 Peak 8 Ave 1261883 4734436 8630325 15857466 23748661 100 500 1000 1500 2500PCB-1260 Peak 1 Ave 4153239 16554914 31025367 45229464 68912349 100 500 1000 1500 2500PCB-1260 Peak 2 Ave 7841143 30454619 57128111 83094008 126227611 100 500 1000 1500 2500PCB-1260 Peak 3 Ave 6845178 27541094 53235986 77818190 121529078 100 500 1000 1500 2500PCB-1260 Peak 4 Ave 3797116 15230911 28586487 41589423 65183263 100 500 1000 1500 2500PCB-1260 Peak 5 Ave 3408191 13295973 25567248 37163734 60754093 100 500 1000 1500 2500PCB-1260 Peak 6 Ave 3898216 17336408 33172625 49966572 79243490 100 500 1000 1500 2500PCB-1260 Peak 7 Ave 2329661 10923449 20031237 30184937 51279969 100 500 1000 1500 2500PCB-1260 Peak 8 Ave 1882356 8691093 16914378 25637846 40032694 100 500 1000 1500 2500DCB Decachlorobiphenyl Ave 13614701 24972013 45507407 65805444 83140007 250 500 100 150 200

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 185 of 323

Data File vr479200d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479200dLab Smp Id IC-SG1660L1_00013 Inj Date 30-SEP-2012 1704 Operator Inst ID PESTGC9iSmp Info ic-SG1660L1_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 7 Calibration Sample Level 1Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2085 2085 0000 2139086 100000 130 8000- 12000 10000(M)

2527 2527 0000 3443416 100000 130 13324- 19985 16098

2777 2777 0000 2014938 100000 110 9975- 14963 9420

3128 3130 -0002 7533379 100000 130 29367- 44051 35218

3329 3330 -0001 2677413 100000 120 11758- 17638 12517

3682 3685 -0003 3086462 100000 130 11464- 17196 14429

4042 4043 -0001 2584175 100000 120 11819- 17728 12081

4190 4191 -0001 1261883 100000 120 5577- 8366 5899

Average of Peak Amounts = 123

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 4153239 100000 130 8000- 12000 10000

10162012Page 186 of 323

Data File vr479200d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 7841143 100000 130 14654- 21981 18880

6964 6964 0000 6845178 100000 120 14108- 21162 16482

7165 7165 0000 3797116 100000 120 7567- 11351 9143

7602 7602 0000 3408191 100000 120 7053- 10579 8206

8893 8893 0000 3898216 100000 110 9199- 13799 9386

9115 9115 0000 2329661 100000 110 5953- 8930 5609

10153 10153 0000 1882356 100000 110 4647- 6971 4532

Average of Peak Amounts = 121

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10625 10624 0001 13614701 250000 29 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 187 of 323

Data File vr479200d

Date 30-SEP-2012 1704

Client ID Instrument PESTGC9i

Sample Info ic-SG1660L1_00013 Operator

10162012Page 188 of 323

Data File vr479201d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479201dLab Smp Id IC-SG1660L2_00013 Inj Date 30-SEP-2012 1720 Operator Inst ID PESTGC9iSmp Info SG1660L2_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 8 Calibration Sample Level 2Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2084 2085 -0001 7913738 500000 500 8000- 12000 10000(M)

2526 2527 -0001 14188692 500000 520 13324- 19985 17929

2776 2777 -0001 9251204 500000 520 9975- 14963 11690

3128 3130 -0002 30672168 500000 520 29367- 44051 38758

3329 3330 -0001 11866731 500000 520 11758- 17638 14995

3682 3685 -0003 12239557 500000 520 11464- 17196 15466

4043 4043 0000 11505820 500000 510 11819- 17728 14539

4190 4191 -0001 4734436 500000 470 5577- 8366 5983

Average of Peak Amounts = 508

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 16554914 500000 510 8000- 12000 10000

10162012Page 189 of 323

Data File vr479201d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6523 6522 0001 30454619 500000 500 14654- 21981 18396

6965 6964 0001 27541094 500000 500 14108- 21162 16636

7165 7165 0000 15230911 500000 500 7567- 11351 9200

7603 7602 0001 13295973 500000 490 7053- 10579 8031

8894 8893 0001 17336408 500000 500 9199- 13799 10472

9115 9115 0000 10923449 500000 520 5953- 8930 6598

10154 10153 0001 8691093 500000 500 4647- 6971 5250

Average of Peak Amounts = 503

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10625 10624 0001 24972013 500000 53 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 190 of 323

Data File vr479201d

Date 30-SEP-2012 1720

Client ID Instrument PESTGC9i

Sample Info SG1660L2_00013 Operator

10162012Page 191 of 323

Data File vr479202d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479202dLab Smp Id IC-SG1660L3_00019 Inj Date 30-SEP-2012 1735 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 9 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2085 2085 0000 14690255 100000 920 8000- 12000 10000(M)

2527 2527 0000 25503333 100000 940 13324- 19985 17361

2777 2777 0000 16986172 100000 950 9975- 14963 11563

3130 3130 0000 55786970 100000 940 29367- 44051 37975

3330 3330 0000 21962918 100000 960 11758- 17638 14951

3685 3685 0000 22517485 100000 950 11464- 17196 15328

4043 4043 0000 21540272 100000 960 11819- 17728 14663

4191 4191 0000 8630325 100000 850 5577- 8366 5875

Average of Peak Amounts = 933

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 31025367 100000 950 8000- 12000 10000

10162012Page 192 of 323

Data File vr479202d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 57128111 100000 940 14654- 21981 18413

6964 6964 0000 53235986 100000 960 14108- 21162 17159

7165 7165 0000 28586487 100000 950 7567- 11351 9214

7602 7602 0000 25567248 100000 940 7053- 10579 8241

8893 8893 0000 33172625 100000 960 9199- 13799 10692

9115 9115 0000 20031237 100000 950 5953- 8930 6456

10153 10153 0000 16914378 100000 980 4647- 6971 5452

Average of Peak Amounts = 955

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 45507407 100000 97 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 193 of 323

Data File vr479202d

Date 30-SEP-2012 1735

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 194 of 323

Data File vr479203d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479203dLab Smp Id IC-SG1660L4_00013 Inj Date 30-SEP-2012 1751 Operator Inst ID PESTGC9iSmp Info SG1660L4_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 10 Calibration Sample Level 4Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2083 2085 -0002 21317999 150000 1300 8000- 12000 10000(M)

2527 2527 0000 37720095 150000 1400 13324- 19985 17694

2775 2777 -0002 25705034 150000 1400 9975- 14963 12058

3128 3130 -0002 82482485 150000 1400 29367- 44051 38691

3328 3330 -0002 32955239 150000 1400 11758- 17638 15459

3683 3685 -0002 31648230 150000 1300 11464- 17196 14846

4042 4043 -0001 32309208 150000 1400 11819- 17728 15156

4188 4191 -0003 15857466 150000 1600 5577- 8366 7439

Average of Peak Amounts = 141e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6071 6072 -0001 45229464 150000 1400 8000- 12000 10000

10162012Page 195 of 323

Data File vr479203d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 83094008 150000 1400 14654- 21981 18372

6963 6964 -0001 77818190 150000 1400 14108- 21162 17205

7164 7165 -0001 41589423 150000 1400 7567- 11351 9195

7602 7602 0000 37163734 150000 1400 7053- 10579 8217

8893 8893 0000 49966572 150000 1400 9199- 13799 11047

9115 9115 0000 30184937 150000 1400 5953- 8930 6674

10153 10153 0000 25637846 150000 1500 4647- 6971 5668

Average of Peak Amounts = 141e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 65805444 150000 140 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 196 of 323

Data File vr479203d

Date 30-SEP-2012 1751

Client ID Instrument PESTGC9i

Sample Info SG1660L4_00013 Operator

10162012Page 197 of 323

Data File vr479204d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479204dLab Smp Id IC-SG1660L5_00013 Inj Date 30-SEP-2012 1807 Operator Inst ID PESTGC9iSmp Info SG1660L5_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 11 Calibration Sample Level 5Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2084 2085 -0001 34065069 250000 2100 8000- 12000 10000(M)

2526 2527 -0001 56733462 250000 2100 13324- 19985 16654

2775 2777 -0002 42475382 250000 2400 9975- 14963 12469

3127 3130 -0003 125050351 250000 2100 29367- 44051 36709

3328 3330 -0002 50069130 250000 2200 11758- 17638 14698

3681 3685 -0004 48815297 250000 2000 11464- 17196 14330

4043 4043 0000 50326849 250000 2200 11819- 17728 14774

4190 4191 -0001 23748661 250000 2300 5577- 8366 6972

Average of Peak Amounts = 219e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6071 6072 -0001 68912349 250000 2100 8000- 12000 10000

10162012Page 198 of 323

Data File vr479204d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6521 6522 -0001 126227611 250000 2100 14654- 21981 18317

6964 6964 0000 121529078 250000 2200 14108- 21162 17635

7164 7165 -0001 65183263 250000 2200 7567- 11351 9459

7601 7602 -0001 60754093 250000 2200 7053- 10579 8816

8892 8893 -0001 79243490 250000 2300 9199- 13799 11499

9114 9115 -0001 51279969 250000 2400 5953- 8930 7441

10153 10153 0000 40032694 250000 2300 4647- 6971 5809

Average of Peak Amounts = 223e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 83140007 200000 180 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 199 of 323

Data File vr479204d

Date 30-SEP-2012 1807

Client ID Instrument PESTGC9i

Sample Info SG1660L5_00013 Operator

10162012Page 200 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vf479205d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1221 Peak 1 16651595 - 17351665PCB-1221 Peak 2 21352065 - 22052135PCB-1221 Peak 3 26722602 - 27422672PCB-1221 Peak 4 28732803 - 29432873PCB-1221 Peak 5 29612891 - 30312961PCB-1221 Peak 6 37393669 - 38093739PCB-1221 Peak 7 40834013 - 41534083PCB-1221 Peak 8 44774407 - 45474477

FORM VI 8082 10162012Page 201 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992612 vf479205d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

47106PCB-1221 Peak 1 Ave 20047106130012961PCB-1221 Peak 2 Ave 20012960750058524PCB-1221 Peak 3 Ave 20058523710040015PCB-1221 Peak 4 Ave 20040015420013789PCB-1221 Peak 5 Ave 20013788908018488PCB-1221 Peak 6 Ave 20018488040061501PCB-1221 Peak 7 Ave 20061500800024165PCB-1221 Peak 8 Ave 200241652800

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 202 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vf479205d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1221 Peak 1 Ave 4710613 1000PCB-1221 Peak 2 Ave 1296075 1000PCB-1221 Peak 3 Ave 5852371 1000PCB-1221 Peak 4 Ave 4001542 1000PCB-1221 Peak 5 Ave 13788908 1000PCB-1221 Peak 6 Ave 1848804 1000PCB-1221 Peak 7 Ave 615008 1000PCB-1221 Peak 8 Ave 2416528 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 203 of 323

Data File vf479205d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479205dLab Smp Id IC-SG1221L3_00014 Inj Date 30-SEP-2012 1822 Operator Inst ID PESTGC9iSmp Info ic SG1221L3_00014Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 12 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12210subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

22 Aroclor-1221 CAS 11104-28-2

1665 1665 0000 4710613 100000 1000 8000- 12000 10000

2135 2135 0000 1296075 100000 1000 2201- 3302 2751

2672 2672 0000 5852371 100000 1000 9939- 14909 12424

2873 2873 0000 4001542 100000 1000 6796- 10194 8495

2961 2961 0000 13788908 100000 1000 23418- 35126 29272

3739 3739 0000 1848804 100000 1000 3140- 4710 3925

4083 4083 0000 615008 100000 1000 1044- 1567 1306

4477 4477 0000 2416528 100000 1000 4104- 6156 5130

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 204 of 323

Data File vf479205d

Date 30-SEP-2012 1822

Client ID Instrument PESTGC9i

Sample Info ic SG1221L3_00014 Operator

10162012Page 205 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vr479205d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1221 Peak 1 11111041 - 11811111PCB-1221 Peak 2 15111441 - 15811511PCB-1221 Peak 3 18601790 - 19301860PCB-1221 Peak 4 20822012 - 21522082PCB-1221 Peak 5 25282458 - 25982528PCB-1221 Peak 6 26022532 - 26722602PCB-1221 Peak 7 26852615 - 27552685PCB-1221 Peak 8 31303060 - 32003130

FORM VI 8082 10162012Page 206 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992612 vr479205d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

64024PCB-1221 Peak 1 Ave 20064024020030571PCB-1221 Peak 2 Ave 20030571000095270PCB-1221 Peak 3 Ave 20095269770024981PCB-1221 Peak 4 Ave 20024981158027336PCB-1221 Peak 5 Ave 20027336400022123PCB-1221 Peak 6 Ave 20022122590041633PCB-1221 Peak 7 Ave 20041632790048909PCB-1221 Peak 8 Ave 200489094700

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 207 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vr479205d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1221 Peak 1 Ave 6402402 1000PCB-1221 Peak 2 Ave 3057100 1000PCB-1221 Peak 3 Ave 9526977 1000PCB-1221 Peak 4 Ave 24981158 1000PCB-1221 Peak 5 Ave 2733640 1000PCB-1221 Peak 6 Ave 2212259 1000PCB-1221 Peak 7 Ave 4163279 1000PCB-1221 Peak 8 Ave 4890947 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 208 of 323

Data File vr479205d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479205dLab Smp Id IC-SG1221L3_00014 Inj Date 30-SEP-2012 1822 Operator Inst ID PESTGC9iSmp Info ic SG1221L3_00014Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 12 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12210subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

22 Aroclor-1221 CAS 11104-28-2

1111 1111 0000 6402402 100000 1000 8000- 12000 10000(M)

1511 1511 0000 3057100 100000 1000 3820- 5730 4775

1860 1860 0000 9526977 100000 1000 11904- 17856 14880

2082 2082 0000 24981158 100000 1000 31215- 46822 39018

2528 2528 0000 2733640 100000 1000 3416- 5124 4270

2602 2602 0000 2212259 100000 1000 2764- 4146 3455

2685 2685 0000 4163279 100000 1000 5202- 7803 6503

3130 3130 0000 4890947 100000 1000 6111- 9167 7639

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 209 of 323

Data File vr479205d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 210 of 323

Data File vr479205d

Date 30-SEP-2012 1822

Client ID Instrument PESTGC9i

Sample Info ic SG1221L3_00014 Operator

10162012Page 211 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vf479206d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1232 Peak 1 29612891 - 30312961PCB-1232 Peak 2 36403570 - 37103640PCB-1232 Peak 3 40854015 - 41554085PCB-1232 Peak 4 47224652 - 47924722PCB-1232 Peak 5 49024832 - 49724902PCB-1232 Peak 6 50875017 - 51575087PCB-1232 Peak 7 55425472 - 56125542PCB-1232 Peak 8 57515681 - 58215751

FORM VI 8082 10162012Page 212 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992613 vf479206d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

97711PCB-1232 Peak 1 Ave 20097710620094688PCB-1232 Peak 2 Ave 20094688030035761PCB-1232 Peak 3 Ave 20035761260066995PCB-1232 Peak 4 Ave 20066994820050607PCB-1232 Peak 5 Ave 20050607280041053PCB-1232 Peak 6 Ave 20041053380057396PCB-1232 Peak 7 Ave 20057395890062677PCB-1232 Peak 8 Ave 200626765000

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 213 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vf479206d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1232 Peak 1 Ave 9771062 1000PCB-1232 Peak 2 Ave 9468803 1000PCB-1232 Peak 3 Ave 3576126 1000PCB-1232 Peak 4 Ave 6699482 1000PCB-1232 Peak 5 Ave 5060728 1000PCB-1232 Peak 6 Ave 4105338 1000PCB-1232 Peak 7 Ave 5739589 1000PCB-1232 Peak 8 Ave 6267650 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 214 of 323

Data File vf479206d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479206dLab Smp Id ic SG1232L3_00013 Inj Date 30-SEP-2012 1838 Operator Inst ID PESTGC9iSmp Info ic SG1232L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 13 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12320subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

23 Aroclor-1232 CAS 11141-16-5

2961 2961 0000 9771062 100000 1000 8000- 12000 10000

3640 3640 0000 9468803 100000 1000 7753- 11629 9691

4085 4085 0000 3576126 100000 1000 2928- 4392 3660

4722 4722 0000 6699482 100000 1000 5485- 8228 6856

4902 4902 0000 5060728 100000 1000 4143- 6215 5179

5087 5087 0000 4105338 100000 1000 3361- 5042 4202

5542 5542 0000 5739589 100000 1000 4699- 7049 5874

5751 5751 0000 6267650 100000 1000 5132- 7697 6415

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 215 of 323

Data File vf479206d

Date 30-SEP-2012 1838

Client ID Instrument PESTGC9i

Sample Info ic SG1232L3_00013 Operator

10162012Page 216 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vr479206d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1232 Peak 1 20822012 - 21522082PCB-1232 Peak 2 25262456 - 25962526PCB-1232 Peak 3 27762706 - 28462776PCB-1232 Peak 4 31283058 - 31983128PCB-1232 Peak 5 33293259 - 33993329PCB-1232 Peak 6 34243354 - 34943424PCB-1232 Peak 7 40423972 - 41124042PCB-1232 Peak 8 46144544 - 46844614

FORM VI 8082 10162012Page 217 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992613 vr479206d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

18402PCB-1232 Peak 1 Ave 20018402354014182PCB-1232 Peak 2 Ave 20014181613010089PCB-1232 Peak 3 Ave 20010089309027669PCB-1232 Peak 4 Ave 20027669356010841PCB-1232 Peak 5 Ave 20010840936085833PCB-1232 Peak 6 Ave 20085833230011581PCB-1232 Peak 7 Ave 20011580551048393PCB-1232 Peak 8 Ave 200483934800

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 218 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vr479206d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1232 Peak 1 Ave 18402354 1000PCB-1232 Peak 2 Ave 14181613 1000PCB-1232 Peak 3 Ave 10089309 1000PCB-1232 Peak 4 Ave 27669356 1000PCB-1232 Peak 5 Ave 10840936 1000PCB-1232 Peak 6 Ave 8583323 1000PCB-1232 Peak 7 Ave 11580551 1000PCB-1232 Peak 8 Ave 4839348 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 219 of 323

Data File vr479206d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479206dLab Smp Id ic SG1232L3_00013 Inj Date 30-SEP-2012 1838 Operator Inst ID PESTGC9iSmp Info ic SG1232L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 13 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12320subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

23 Aroclor-1232 CAS 11141-16-5

2082 2082 0000 18402354 100000 1000 8000- 12000 10000

2526 2526 0000 14181613 100000 1000 6165- 9248 7706

2776 2776 0000 10089309 100000 1000 4386- 6579 5483

3128 3128 0000 27669356 100000 1000 12029- 18043 15036

3329 3329 0000 10840936 100000 1000 4713- 7069 5891

3424 3424 0000 8583323 100000 1000 3731- 5597 4664

4042 4042 0000 11580551 100000 1000 5034- 7552 6293

4614 4614 0000 4839348 100000 1000 2104- 3156 2630

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 220 of 323

Data File vr479206d

Date 30-SEP-2012 1838

Client ID Instrument PESTGC9i

Sample Info ic SG1232L3_00013 Operator

10162012Page 221 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vf479207d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1242 Peak 1 29612891 - 30312961PCB-1242 Peak 2 36413571 - 37113641PCB-1242 Peak 3 40864016 - 41564086PCB-1242 Peak 4 44794409 - 45494479PCB-1242 Peak 5 47234653 - 47934723PCB-1242 Peak 6 51585088 - 52285158PCB-1242 Peak 7 57525682 - 58225752PCB-1242 Peak 8 62656195 - 63356265

FORM VI 8082 10162012Page 222 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992614 vf479207d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

81414PCB-1242 Peak 1 Ave 20081414290015365PCB-1242 Peak 2 Ave 20015365311065982PCB-1242 Peak 3 Ave 20065981950028106PCB-1242 Peak 4 Ave 20028106459012209PCB-1242 Peak 5 Ave 20012208628069961PCB-1242 Peak 6 Ave 20069960990010615PCB-1242 Peak 7 Ave 20010615499010283PCB-1242 Peak 8 Ave 200102828980

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 223 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vf479207d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1242 Peak 1 Ave 8141429 1000PCB-1242 Peak 2 Ave 15365311 1000PCB-1242 Peak 3 Ave 6598195 1000PCB-1242 Peak 4 Ave 28106459 1000PCB-1242 Peak 5 Ave 12208628 1000PCB-1242 Peak 6 Ave 6996099 1000PCB-1242 Peak 7 Ave 10615499 1000PCB-1242 Peak 8 Ave 10282898 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 224 of 323

Data File vf479207d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479207dLab Smp Id ic SG1242L3_00013 Inj Date 30-SEP-2012 1854 Operator Inst ID PESTGC9iSmp Info ic SG1242L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 14 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12420subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

24 Aroclor-1242 CAS 53469-21-9

2961 2961 0000 8141429 100000 1000 8000- 12000 10000(M)

3641 3641 0000 15365311 100000 1000 15098- 22648 18873

4086 4086 0000 6598195 100000 1000 6484- 9725 8104

4479 4479 0000 28106459 100000 1000 27618- 41427 34523

4723 4723 0000 12208628 100000 1000 11997- 17995 14996

5158 5158 0000 6996099 100000 1000 6875- 10312 8593

5752 5752 0000 10615499 100000 1000 10431- 15647 13039

6265 6265 0000 10282898 100000 1000 10104- 15156 12630

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 225 of 323

Data File vf479207d Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 226 of 323

Data File vf479207d

Date 30-SEP-2012 1854

Client ID Instrument PESTGC9i

Sample Info ic SG1242L3_00013 Operator

10162012Page 227 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vr479207d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1242 Peak 1 20832013 - 21532083PCB-1242 Peak 2 25272457 - 25972527PCB-1242 Peak 3 27772707 - 28472777PCB-1242 Peak 4 31293059 - 31993129PCB-1242 Peak 5 33293259 - 33993329PCB-1242 Peak 6 36853615 - 37553685PCB-1242 Peak 7 40443974 - 41144044PCB-1242 Peak 8 51265056 - 51965126

FORM VI 8082 10162012Page 228 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992614 vr479207d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

13527PCB-1242 Peak 1 Ave 20013526845020219PCB-1242 Peak 2 Ave 20020218998014340PCB-1242 Peak 3 Ave 20014339987044262PCB-1242 Peak 4 Ave 20044261735017388PCB-1242 Peak 5 Ave 20017387684018314PCB-1242 Peak 6 Ave 20018314121017750PCB-1242 Peak 7 Ave 20017749733015393PCB-1242 Peak 8 Ave 200153932670

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 229 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vr479207d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1242 Peak 1 Ave 13526845 1000PCB-1242 Peak 2 Ave 20218998 1000PCB-1242 Peak 3 Ave 14339987 1000PCB-1242 Peak 4 Ave 44261735 1000PCB-1242 Peak 5 Ave 17387684 1000PCB-1242 Peak 6 Ave 18314121 1000PCB-1242 Peak 7 Ave 17749733 1000PCB-1242 Peak 8 Ave 15393267 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 230 of 323

Data File vr479207d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479207dLab Smp Id ic SG1242L3_00013 Inj Date 30-SEP-2012 1854 Operator Inst ID PESTGC9iSmp Info ic SG1242L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 14 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12420subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

24 Aroclor-1242 CAS 53469-21-9

2083 2083 0000 13526845 100000 1000 8000- 12000 10000(M)

2527 2527 0000 20218998 100000 1000 11958- 17937 14947

2777 2777 0000 14339987 100000 1000 8481- 12721 10601

3129 3129 0000 44261735 100000 1000 26177- 39266 32721

3329 3329 0000 17387684 100000 1000 10283- 15425 12854

3685 3685 0000 18314121 100000 1000 10831- 16247 13539

4044 4044 0000 17749733 100000 1000 10497- 15746 13122

5126 5126 0000 15393267 100000 1000 9104- 13656 11380

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 231 of 323

Data File vr479207d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 232 of 323

Data File vr479207d

Date 30-SEP-2012 1854

Client ID Instrument PESTGC9i

Sample Info ic SG1242L3_00013 Operator

10162012Page 233 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vf479208d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1248 Peak 1 36373567 - 37073637PCB-1248 Peak 2 44734403 - 45434473PCB-1248 Peak 3 49514881 - 50214951PCB-1248 Peak 4 50865016 - 51565086PCB-1248 Peak 5 55415471 - 56115541PCB-1248 Peak 6 57505680 - 58205750PCB-1248 Peak 7 61916121 - 62616191PCB-1248 Peak 8 62626192 - 63326262

FORM VI 8082 10162012Page 234 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992615 vf479208d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

89356PCB-1248 Peak 1 Ave 20089355610020760PCB-1248 Peak 2 Ave 20020759623031559PCB-1248 Peak 3 Ave 20031559070012341PCB-1248 Peak 4 Ave 20012341389015809PCB-1248 Peak 5 Ave 20015808884017466PCB-1248 Peak 6 Ave 20017465791016624PCB-1248 Peak 7 Ave 20016623508019431PCB-1248 Peak 8 Ave 200194311040

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 235 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vf479208d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1248 Peak 1 Ave 8935561 1000PCB-1248 Peak 2 Ave 20759623 1000PCB-1248 Peak 3 Ave 3155907 1000PCB-1248 Peak 4 Ave 12341389 1000PCB-1248 Peak 5 Ave 15808884 1000PCB-1248 Peak 6 Ave 17465791 1000PCB-1248 Peak 7 Ave 16623508 1000PCB-1248 Peak 8 Ave 19431104 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 236 of 323

Data File vf479208d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479208dLab Smp Id ic SG1248L3_00013 Inj Date 30-SEP-2012 1909 Operator Inst ID PESTGC9iSmp Info ic SG1248L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 15 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12480subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

25 Aroclor-1248 CAS 12672-29-6

3637 3637 0000 8935561 100000 1000 8000- 12000 10000

4473 4473 0000 20759623 100000 1000 18586- 27879 23233

4951 4951 0000 3155907 100000 1000 2825- 4238 3532

5086 5086 0000 12341389 100000 1000 11049- 16574 13812

5541 5541 0000 15808884 100000 1000 14154- 21231 17692

5750 5750 0000 17465791 100000 1000 15637- 23456 19546

6191 6191 0000 16623508 100000 1000 14883- 22325 18604

6262 6262 0000 19431104 100000 1000 17397- 26095 21746

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 237 of 323

Data File vf479208d

Date 30-SEP-2012 1909

Client ID Instrument PESTGC9i

Sample Info ic SG1248L3_00013 Operator

10162012Page 238 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vr479208d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1248 Peak 1 25252455 - 25952525PCB-1248 Peak 2 31243054 - 31943124PCB-1248 Peak 3 34233353 - 34933423PCB-1248 Peak 4 36783608 - 37483678PCB-1248 Peak 5 40413971 - 41114041PCB-1248 Peak 6 41864116 - 42564186PCB-1248 Peak 7 46154545 - 46854615PCB-1248 Peak 8 51245054 - 51945124

FORM VI 8082 10162012Page 239 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992615 vr479208d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

11417PCB-1248 Peak 1 Ave 20011416682034274PCB-1248 Peak 2 Ave 20034273988063635PCB-1248 Peak 3 Ave 20063635020034030PCB-1248 Peak 4 Ave 20034030097030220PCB-1248 Peak 5 Ave 20030220358018203PCB-1248 Peak 6 Ave 20018202681015611PCB-1248 Peak 7 Ave 20015610993034370PCB-1248 Peak 8 Ave 200343696460

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 240 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vr479208d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1248 Peak 1 Ave 11416682 1000PCB-1248 Peak 2 Ave 34273988 1000PCB-1248 Peak 3 Ave 6363502 1000PCB-1248 Peak 4 Ave 34030097 1000PCB-1248 Peak 5 Ave 30220358 1000PCB-1248 Peak 6 Ave 18202681 1000PCB-1248 Peak 7 Ave 15610993 1000PCB-1248 Peak 8 Ave 34369646 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 241 of 323

Data File vr479208d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479208dLab Smp Id ic SG1248L3_00013 Inj Date 30-SEP-2012 1909 Operator Inst ID PESTGC9iSmp Info ic SG1248L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 15 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12480subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

25 Aroclor-1248 CAS 12672-29-6

2525 2525 0000 11416682 100000 1000 8000- 12000 10000(M)

3124 3124 0000 34273988 100000 1000 24017- 36025 30021

3423 3423 0000 6363502 100000 1000 4459- 6689 5574

3678 3678 0000 34030097 100000 1000 23846- 35769 29807

4041 4041 0000 30220358 100000 1000 21176- 31764 26470

4186 4186 0000 18202681 100000 1000 12755- 19133 15944

4615 4615 0000 15610993 100000 1000 10939- 16409 13674

5124 5124 0000 34369646 100000 1000 24084- 36126 30105

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 242 of 323

Data File vr479208d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 243 of 323

Data File vr479208d

Date 30-SEP-2012 1909

Client ID Instrument PESTGC9i

Sample Info ic SG1248L3_00013 Operator

10162012Page 244 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vf479209d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1254 Peak 1 50855015 - 51555085PCB-1254 Peak 2 62536183 - 63236253PCB-1254 Peak 3 65806510 - 66506580PCB-1254 Peak 4 71577087 - 72277157PCB-1254 Peak 5 73717301 - 74417371PCB-1254 Peak 6 85968526 - 86668596PCB-1254 Peak 7 90869016 - 91569086PCB-1254 Peak 8 98439773 - 99139843

FORM VI 8082 10162012Page 245 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992616 vf479209d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

97124PCB-1254 Peak 1 Ave 20097124230016374PCB-1254 Peak 2 Ave 20016373834017590PCB-1254 Peak 3 Ave 20017589776013684PCB-1254 Peak 4 Ave 20013683949027505PCB-1254 Peak 5 Ave 20027504947017262PCB-1254 Peak 6 Ave 20017261880028714PCB-1254 Peak 7 Ave 20028713900074774PCB-1254 Peak 8 Ave 200747739500

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 246 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vf479209d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1254 Peak 1 Ave 9712423 1000PCB-1254 Peak 2 Ave 16373834 1000PCB-1254 Peak 3 Ave 17589776 1000PCB-1254 Peak 4 Ave 13683949 1000PCB-1254 Peak 5 Ave 27504947 1000PCB-1254 Peak 6 Ave 17261880 1000PCB-1254 Peak 7 Ave 28713900 1000PCB-1254 Peak 8 Ave 7477395 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 247 of 323

Data File vf479209d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479209dLab Smp Id ic SG1254L3_00013 Inj Date 30-SEP-2012 1925 Operator Inst ID PESTGC9iSmp Info ic SG1254L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 16 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12540subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

26 Aroclor-1254 CAS 11097-69-1

5085 5085 0000 9712423 100000 1000 8000- 12000 10000

6253 6253 0000 16373834 100000 1000 13487- 20230 16859

6580 6580 0000 17589776 100000 1000 14488- 21733 18111

7157 7157 0000 13683949 100000 1000 11271- 16907 14089

7371 7371 0000 27504947 100000 1000 22655- 33983 28319

8596 8596 0000 17261880 100000 1000 14218- 21328 17773

9086 9086 0000 28713900 100000 1000 23651- 35477 29564

9843 9843 0000 7477395 100000 1000 6159- 9239 7699

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 248 of 323

Data File vf479209d

Date 30-SEP-2012 1925

Client ID Instrument PESTGC9i

Sample Info ic SG1254L3_00013 Operator

10162012Page 249 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vr479209d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1254 Peak 1 46874617 - 47574687PCB-1254 Peak 2 47624692 - 48324762PCB-1254 Peak 3 51285058 - 51985128PCB-1254 Peak 4 55695499 - 56395569PCB-1254 Peak 5 57705700 - 58405770PCB-1254 Peak 6 62216151 - 62916221PCB-1254 Peak 7 65216451 - 65916521PCB-1254 Peak 8 69656895 - 70356965

FORM VI 8082 10162012Page 250 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992616 vr479209d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

24886PCB-1254 Peak 1 Ave 20024885981024126PCB-1254 Peak 2 Ave 20024125717033197PCB-1254 Peak 3 Ave 20033196979024470PCB-1254 Peak 4 Ave 20024470162043009PCB-1254 Peak 5 Ave 20043008616038112PCB-1254 Peak 6 Ave 20038111884031186PCB-1254 Peak 7 Ave 20031186488041987PCB-1254 Peak 8 Ave 200419870070

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 251 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vr479209d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1254 Peak 1 Ave 24885981 1000PCB-1254 Peak 2 Ave 24125717 1000PCB-1254 Peak 3 Ave 33196979 1000PCB-1254 Peak 4 Ave 24470162 1000PCB-1254 Peak 5 Ave 43008616 1000PCB-1254 Peak 6 Ave 38111884 1000PCB-1254 Peak 7 Ave 31186488 1000PCB-1254 Peak 8 Ave 41987007 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 252 of 323

Data File vr479209d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479209dLab Smp Id ic SG1254L3_00013 Inj Date 30-SEP-2012 1925 Operator Inst ID PESTGC9iSmp Info ic SG1254L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 16 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12540subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

26 Aroclor-1254 CAS 11097-69-1

4687 4687 0000 24885981 100000 1000 8000- 12000 10000(M)

4762 4762 0000 24125717 100000 1000 7756- 11633 9695

5128 5128 0000 33196979 100000 1000 10672- 16008 13340

5569 5569 0000 24470162 100000 1000 7866- 11799 9833

5770 5770 0000 43008616 100000 1000 13826- 20739 17282

6221 6221 0000 38111884 100000 1000 12252- 18378 15315

6521 6521 0000 31186488 100000 1000 10025- 15038 12532

6965 6965 0000 41987007 100000 1000 13497- 20246 16872

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 253 of 323

Data File vr479209d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 254 of 323

Data File vr479209d

Date 30-SEP-2012 1925

Client ID Instrument PESTGC9i

Sample Info ic SG1254L3_00013 Operator

10162012Page 255 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-2

TestAmerica Edison

Lab File ID vf479493d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1005610273 979 1000 -21 150Ave

PCB-1016 Peak 2 2214321113 1050 1000 49 150Ave

PCB-1016 Peak 3 96058714 1100 1000 102 150Ave

PCB-1016 Peak 4 4004137710 1060 1000 62 150Ave

PCB-1016 Peak 5 1906116455 1160 1000 158 150Ave

PCB-1016 Peak 6 104069770 1070 1000 65 150Ave

PCB-1016 Peak 7 1271211990 1060 1000 60 150Ave

PCB-1016 Peak 8 1381712146 1140 1000 138 150Ave

PCB-1260 Peak 1 2403322106 1090 1000 87 150Ave

PCB-1260 Peak 2 2694125092 1070 1000 74 150Ave

PCB-1260 Peak 3 4112136867 1120 1000 115 150Ave

PCB-1260 Peak 4 1829116241 1130 1000 126 150Ave

PCB-1260 Peak 5 102408814 1160 1000 162 150Ave

PCB-1260 Peak 6 1863416926 1100 1000 101 150Ave

PCB-1260 Peak 7 2108721064 1000 1000 01 150Ave

PCB-1260 Peak 8 80147857 1020 1000 20 150Ave

DCB Decachlorobiphenyl 267686265963 101 100 06 150Ave

FORM VII 8082

10162012Page 256 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-2

TestAmerica Edison

Lab File ID vf479493d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 292 289 303

PCB-1016 Peak 2 359 357 371

PCB-1016 Peak 3 404 401 415

PCB-1016 Peak 4 443 441 455

PCB-1016 Peak 5 468 465 479

PCB-1016 Peak 6 511 509 523

PCB-1016 Peak 7 550 547 561

PCB-1016 Peak 8 571 568 582

PCB-1260 Peak 1 771 769 783

PCB-1260 Peak 2 816 814 828

PCB-1260 Peak 3 902 901 915

PCB-1260 Peak 4 928 926 940

PCB-1260 Peak 5 940 938 952

PCB-1260 Peak 6 986 983 997

PCB-1260 Peak 7 1059 1055 1069

PCB-1260 Peak 8 1106 1102 1116

DCB Decachlorobiphenyl 1149 1141 1161

Form VII 8082

10162012Page 257 of 323

Data File vf479493d Report Date 09-Oct-2012 0318

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479493dLab Smp Id ccvrtsg1660l3_00019 Inj Date 08-OCT-2012 1830 Operator Inst ID PESTGC9iSmp Info ccvrt-sg1660l3_00019Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 21 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2923 2961 -0038 10055641 978875 650 8000- 12000 10000(M)

3593 3641 -0048 22143043 104879 700 16892- 25338 22021

4036 4085 -0049 9604932 110224 730 6889- 10334 9552

4432 4479 -0047 40041013 106181 710 30481- 45721 39819

4678 4722 -0044 19061275 115840 770 13320- 19980 18956

5114 5158 -0044 10405886 106506 710 7564- 11346 10348

5500 5542 -0042 12711848 106020 710 9332- 13998 12642

5709 5752 -0043 13817418 113758 760 9784- 14675 13741

Average of Peak Concentrations = 720

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7706 7756 -0050 24033075 108715 720 8000- 12000 10000(M)

10162012Page 258 of 323

Data File vf479493d Report Date 09-Oct-2012 0318

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8161 8215 -0054 26941342 107369 720 9103- 13655 11210

9020 9084 -0064 41121424 111541 740 14090- 21136 17110

9276 9332 -0056 18291174 112626 750 6105- 9158 7611

9401 9454 -0053 10239798 116171 770 3460- 5190 4261

9861 9901 -0040 18634445 110097 730 6444- 9666 7754

10594 10616 -0022 21087197 100112 670 7926- 11889 12194

11063 11086 -0023 8014273 101999 680 2968- 4452 3335

Average of Peak Concentrations = 720

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11488 11515 -0027 26768608 100648 67 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 259 of 323

Data File vf479493d

Date 08-OCT-2012 1830

Client ID Instrument PESTGC9i

Sample Info ccvrt-sg1660l3_00019 Operator

10162012Page 260 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-1

TestAmerica Edison

Lab File ID vr479493d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1317915949 826 1000 -174 150Ave

PCB-1016 Peak 2 2492127231 915 1000 -85 150Ave

PCB-1016 Peak 3 1751817953 976 1000 -24 150Ave

PCB-1016 Peak 4 5583559495 938 1000 -62 150Ave

PCB-1016 Peak 5 2224122894 971 1000 -29 150Ave

PCB-1016 Peak 6 2383923697 1010 1000 06 150Ave

PCB-1016 Peak 7 2233922413 997 1000 -03 150Ave

PCB-1016 Peak 8 1103010158 1090 1000 86 150Ave

PCB-1260 Peak 1 3241432677 992 1000 -08 150Ave

PCB-1260 Peak 2 6068660467 1000 1000 04 150Ave

PCB-1260 Peak 3 5752255452 1040 1000 37 150Ave

PCB-1260 Peak 4 2973730164 986 1000 -14 150Ave

PCB-1260 Peak 5 2720927064 1010 1000 05 150Ave

PCB-1260 Peak 6 3391634367 987 1000 -13 150Ave

PCB-1260 Peak 7 2498721162 1180 1000 181 150Ave

PCB-1260 Peak 8 1900217245 1100 1000 102 150Ave

DCB Decachlorobiphenyl 482177470701 102 100 24 150Ave

FORM VII 8082

10162012Page 261 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-1

TestAmerica Edison

Lab File ID vr479493d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 206 201 215

PCB-1016 Peak 2 250 246 260

PCB-1016 Peak 3 275 271 285

PCB-1016 Peak 4 310 306 320

PCB-1016 Peak 5 330 326 340

PCB-1016 Peak 6 365 361 375

PCB-1016 Peak 7 401 397 411

PCB-1016 Peak 8 416 412 426

PCB-1260 Peak 1 604 600 614

PCB-1260 Peak 2 650 645 659

PCB-1260 Peak 3 694 689 703

PCB-1260 Peak 4 714 709 723

PCB-1260 Peak 5 757 753 767

PCB-1260 Peak 6 886 882 896

PCB-1260 Peak 7 908 904 918

PCB-1260 Peak 8 1013 1008 1022

DCB Decachlorobiphenyl 1061 1052 1072

Form VII 8082

10162012Page 262 of 323

Data File vr479493d Page 1 Report Date 09-Oct-2012 0318

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479493dLab Smp Id ccvrtsg1660l3_00019 Inj Date 08-OCT-2012 1830 Operator Inst ID PESTGC9iSmp Info ccvrt-sg1660l3_00019Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 21 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2056 2085 -0029 13178629 826281 550 8000- 12000 10000(M)

2498 2527 -0029 24921299 915181 610 13324- 19985 18910

2746 2777 -0031 17517717 975756 650 9975- 14963 13293

3100 3130 -0030 55834574 938480 620 29367- 44051 42368

3297 3330 -0033 22240639 971476 650 11758- 17638 16876

3648 3685 -0037 23838665 100597 670 11464- 17196 18089

4011 4043 -0032 22339236 996719 660 11819- 17728 16951

4157 4191 -0034 11029779 108584 720 5577- 8366 8369

Average of Peak Concentrations = 640

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6045 6072 -0027 32414247 991956 660 8000- 12000 10000(M)

10162012Page 263 of 323

Data File vr479493d Page 2 Report Date 09-Oct-2012 0318

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6496 6522 -0026 60686283 100362 670 14654- 21981 18722

6938 6964 -0026 57521890 103733 690 14108- 21162 17746

7137 7165 -0028 29736966 985849 660 7567- 11351 9174

7572 7602 -0030 27208663 100536 670 7053- 10579 8394

8857 8893 -0036 33916486 986885 660 9199- 13799 10463

9076 9115 -0039 24987061 118075 790 5953- 8930 7709

10135 10153 -0018 19001807 110187 730 4647- 6971 5862

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 48217685 102438 68 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 264 of 323

Data File vr479493d

Date 08-OCT-2012 1830

Client ID Instrument PESTGC9i

Sample Info ccvrt-sg1660l3_00019 Operator

10162012Page 265 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-2

TestAmerica Edison

Lab File ID vf479510d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 998310273 972 1000 -28 150Ave

PCB-1016 Peak 2 2182221113 1030 1000 34 150Ave

PCB-1016 Peak 3 93438714 1070 1000 72 150Ave

PCB-1016 Peak 4 3888937710 1030 1000 31 150Ave

PCB-1016 Peak 5 1831616455 1110 1000 113 150Ave

PCB-1016 Peak 6 100909770 1030 1000 33 150Ave

PCB-1016 Peak 7 1211711990 1010 1000 11 150Ave

PCB-1016 Peak 8 1287812146 1060 1000 60 150Ave

PCB-1260 Peak 1 2305022106 1040 1000 43 150Ave

PCB-1260 Peak 2 2601125092 1040 1000 37 150Ave

PCB-1260 Peak 3 4009636867 1090 1000 88 150Ave

PCB-1260 Peak 4 1793216241 1100 1000 104 150Ave

PCB-1260 Peak 5 100168814 1140 1000 136 150Ave

PCB-1260 Peak 6 1799416926 1060 1000 63 150Ave

PCB-1260 Peak 7 2148621064 1020 1000 20 150Ave

PCB-1260 Peak 8 78557857 1000 1000 -00 150Ave

DCB Decachlorobiphenyl 262499265963 987 100 -13 150Ave

FORM VII 8082

10162012Page 266 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-2

TestAmerica Edison

Lab File ID vf479510d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 292 289 303

PCB-1016 Peak 2 359 357 371

PCB-1016 Peak 3 403 401 415

PCB-1016 Peak 4 443 441 455

PCB-1016 Peak 5 468 465 479

PCB-1016 Peak 6 511 509 523

PCB-1016 Peak 7 550 547 561

PCB-1016 Peak 8 571 568 582

PCB-1260 Peak 1 770 769 783

PCB-1260 Peak 2 816 814 828

PCB-1260 Peak 3 902 901 915

PCB-1260 Peak 4 927 926 940

PCB-1260 Peak 5 940 938 952

PCB-1260 Peak 6 986 983 997

PCB-1260 Peak 7 1059 1055 1069

PCB-1260 Peak 8 1106 1102 1116

DCB Decachlorobiphenyl 1149 1141 1161

Form VII 8082

10162012Page 267 of 323

Data File vf479510d Report Date 09-Oct-2012 0335

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479510dLab Smp Id ccv-SG1660L3_00019 Inj Date 09-OCT-2012 0147 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 40 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2922 2961 -0039 9983429 971845 650 8000- 12000 10000(M)

3591 3641 -0050 21822420 103360 690 16892- 25338 21859

4034 4085 -0051 9342806 107216 710 6889- 10334 9358

4431 4479 -0048 38888611 103125 690 30481- 45721 38953

4677 4722 -0045 18315559 111308 740 13320- 19980 18346

5112 5158 -0046 10089629 103269 690 7564- 11346 10106

5497 5542 -0045 12117410 101063 670 9332- 13998 12138

5706 5752 -0046 12878214 106025 710 9784- 14675 12900

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7703 7756 -0053 23050032 104269 700 8000- 12000 10000(M)

10162012Page 268 of 323

Data File vf479510d Report Date 09-Oct-2012 0335

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8159 8215 -0056 26011086 103662 690 9103- 13655 11285

9017 9084 -0067 40095841 108759 720 14090- 21136 17395

9273 9332 -0059 17931794 110413 740 6105- 9158 7780

9399 9454 -0055 10016237 113634 760 3460- 5190 4345

9858 9901 -0043 17994170 106314 710 6444- 9666 7807

10594 10616 -0022 21485546 102003 680 7926- 11889 12478

11061 11086 -0025 7855172 999743 670 2968- 4452 3408

Average of Peak Concentrations = 710

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11485 11515 -0030 26249946 986977 66 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 269 of 323

Data File vf479510d

Date 09-OCT-2012 0147

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 270 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-1

TestAmerica Edison

Lab File ID vr479510d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1577315949 989 1000 -11 150Ave

PCB-1016 Peak 2 2637627231 969 1000 -31 150Ave

PCB-1016 Peak 3 1911517953 1060 1000 65 150Ave

PCB-1016 Peak 4 5729159495 963 1000 -37 150Ave

PCB-1016 Peak 5 2290722894 1000 1000 00 150Ave

PCB-1016 Peak 6 2510823697 1060 1000 60 150Ave

PCB-1016 Peak 7 2349222413 1050 1000 48 150Ave

PCB-1016 Peak 8 1095310158 1080 1000 78 150Ave

PCB-1260 Peak 1 3177332677 972 1000 -28 150Ave

PCB-1260 Peak 2 5864160467 970 1000 -30 150Ave

PCB-1260 Peak 3 5561155452 1000 1000 03 150Ave

PCB-1260 Peak 4 2920530164 968 1000 -32 150Ave

PCB-1260 Peak 5 2692527064 995 1000 -05 150Ave

PCB-1260 Peak 6 3316834367 965 1000 -35 150Ave

PCB-1260 Peak 7 2309521162 1090 1000 91 150Ave

PCB-1260 Peak 8 1649517245 957 1000 -43 150Ave

DCB Decachlorobiphenyl 444399470701 944 100 -56 150Ave

FORM VII 8082

10162012Page 271 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-1

TestAmerica Edison

Lab File ID vr479510d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 206 201 215

PCB-1016 Peak 2 250 246 260

PCB-1016 Peak 3 275 271 285

PCB-1016 Peak 4 310 306 320

PCB-1016 Peak 5 330 326 340

PCB-1016 Peak 6 365 361 375

PCB-1016 Peak 7 401 397 411

PCB-1016 Peak 8 416 412 426

PCB-1260 Peak 1 604 600 614

PCB-1260 Peak 2 649 645 659

PCB-1260 Peak 3 694 689 703

PCB-1260 Peak 4 714 709 723

PCB-1260 Peak 5 757 753 767

PCB-1260 Peak 6 885 882 896

PCB-1260 Peak 7 907 904 918

PCB-1260 Peak 8 1013 1008 1022

DCB Decachlorobiphenyl 1061 1052 1072

Form VII 8082

10162012Page 272 of 323

Data File vr479510d Page 1 Report Date 09-Oct-2012 0335

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479510dLab Smp Id ccv-SG1660L3_00019 Inj Date 09-OCT-2012 0147 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 40 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2056 2085 -0029 15772630 988922 660 8000- 12000 10000(M)

2498 2527 -0029 26375750 968593 640 13324- 19985 16722

2747 2777 -0030 19114706 106471 710 9975- 14963 12119

3099 3130 -0031 57290957 962959 640 29367- 44051 36323

3296 3330 -0034 22907341 100060 670 11758- 17638 14523

3645 3685 -0040 25108132 105954 710 11464- 17196 15919

4009 4043 -0034 23491941 104815 700 11819- 17728 14894

4155 4191 -0036 10952986 107828 720 5577- 8366 6944

Average of Peak Concentrations = 680

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6043 6072 -0029 31772880 972329 650 8000- 12000 10000(M)

10162012Page 273 of 323

Data File vr479510d Page 2 Report Date 09-Oct-2012 0335

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6494 6522 -0028 58641225 969803 650 14654- 21981 18456

6936 6964 -0028 55611337 100287 670 14108- 21162 17503

7135 7165 -0030 29205460 968228 640 7567- 11351 9192

7570 7602 -0032 26925453 994891 660 7053- 10579 8474

8854 8893 -0039 33168029 965107 640 9199- 13799 10439

9072 9115 -0043 23094940 109134 730 5953- 8930 7269

10132 10153 -0021 16495029 956510 640 4647- 6971 5192

Average of Peak Concentrations = 660

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 44439946 944122 63 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 274 of 323

Data File vr479510d

Date 09-OCT-2012 0147

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 275 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1309971-A

Matrix vf479496dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2208

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

88 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 276 of 323

Data File vf479496d Report Date 09-Oct-2012 0319

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479496dLab Smp Id MB 460-1309971-a Inj Date 08-OCT-2012 2208 Operator Inst ID PESTGC9iSmp Info MB 460-1309971-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 24 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11484 11515 -0031 23517325 884233 59 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 277 of 323

Data File vf479496d

Date 08-OCT-2012 2208

Client ID Instrument PESTGC9i

Sample Info MB 460-1309971-a Operator

10162012Page 278 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1309971-A

Matrix vr479496dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2208

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

97 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 279 of 323

Data File vr479496d Page 1 Report Date 09-Oct-2012 0319

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479496dLab Smp Id MB 460-1309971-a Inj Date 08-OCT-2012 2208 Operator Inst ID PESTGC9iSmp Info MB 460-1309971-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 24 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 45589434 968543 64 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 280 of 323

Data File vr479496d

Date 08-OCT-2012 2208

Client ID Instrument PESTGC9i

Sample Info MB 460-1309971-a Operator

10162012Page 281 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-1311371

Matrix vf479492dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10082012 1814Sample wtvol

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

114 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 282 of 323

Data File vf479492d Page 1 Report Date 09-Oct-2012 0317

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479492dLab Smp Id piblk-sgpiblk_00013 Inj Date 08-OCT-2012 1814 Operator Inst ID PESTGC9iSmp Info sgpiblk_00013Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 20 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11496 11515 -0019 6086041 228830 15 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 283 of 323

Data File vf479492d

Date 08-OCT-2012 1814

Client ID Instrument PESTGC9i

Sample Info sgpiblk_00013 Operator

10162012Page 284 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-1311371

Matrix vr479492dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10082012 1814Sample wtvol

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

114 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 285 of 323

Data File vr479492d Report Date 09-Oct-2012 0317

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479492dLab Smp Id piblk-sgpiblk_00013 Inj Date 08-OCT-2012 1814 Operator Inst ID PESTGC9iSmp Info sgpiblk_00013Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 20 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 10738471 228138 15 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 286 of 323

Data File vr479492d

Date 08-OCT-2012 1814

Client ID Instrument PESTGC9i

Sample Info sgpiblk_00013 Operator

10162012Page 287 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-13113718

Matrix vf479509dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10092012 0131Sample wtvol

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

122 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 288 of 323

Data File vf479509d Report Date 09-Oct-2012 0313

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479509dLab Smp Id SGPIBLK_00013 Inj Date 09-OCT-2012 0131 Operator Inst ID PESTGC9iSmp Info SGPIBLK_00013Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 39 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11487 11515 -0028 6469383 243244 16 8000- 12000 10000(a)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 289 of 323

Data File vf479509d

Date 09-OCT-2012 0131

Client ID Instrument PESTGC9i

Sample Info SGPIBLK_00013 Operator

10162012Page 290 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-13113718

Matrix vr479509dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10092012 0131Sample wtvol

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

102 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 291 of 323

Data File vr479509d Report Date 09-Oct-2012 0306

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479509dLab Smp Id SGPIBLK_00013 Inj Date 09-OCT-2012 0131 Operator Inst ID PESTGC9iSmp Info SGPIBLK_00013Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 39 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 9634357 204681 14 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 292 of 323

Data File vr479509d

Date 09-OCT-2012 0131

Client ID Instrument PESTGC9i

Sample Info SGPIBLK_00013 Operator

10162012Page 293 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1309972-A

Matrix vf479497dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2224

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 507

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 557

RECCAS NO LIMITSQSURROGATE

84 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 294 of 323

Data File vf479497d Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479497dLab Smp Id LCS 460-1309972-a Inj Date 08-OCT-2012 2224 Operator Inst ID PESTGC9iSmp Info LCS 460-1309972-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 25 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2926 2961 -0035 10792080 105056 700 8000- 12000 10000

3596 3641 -0045 23726579 112379 750 16892- 25338 21985

4040 4085 -0045 9881475 113398 760 6889- 10334 9156

4437 4479 -0042 42082916 111596 740 30481- 45721 38994

4683 4722 -0039 19556228 118847 790 13320- 19980 18121

5181 5158 0023 7863050 804795 540 7564- 11346 7286

5572 5542 0030 6208245 517785 340 9332- 13998 5753

5713 5752 -0039 14198514 116895 780 9784- 14675 13156

Average of Peak Concentrations = 680

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7711 7756 -0045 26515963 119947 800 8000- 12000 10000(M)

10162012Page 295 of 323

Data File vf479497d Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8168 8215 -0047 29809525 118800 790 9103- 13655 11242

9026 9084 -0058 46049501 124909 830 14090- 21136 17367

9283 9332 -0049 20194161 124344 830 6105- 9158 7616

9408 9454 -0046 11340121 128654 860 3460- 5190 4277

9864 9901 -0037 20709127 122354 820 6444- 9666 7810

10623 10616 0007 8913638 423178 280 7926- 11889 3362

11063 11086 -0023 8650385 110095 730 2968- 4452 3262

Average of Peak Concentrations = 740

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11484 11515 -0031 22216113 835308 56 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 296 of 323

Data File vf479497d

Date 08-OCT-2012 2224

Client ID Instrument PESTGC9i

Sample Info LCS 460-1309972-a Operator

10162012Page 297 of 323

Manual Integration Report

Data File vf479497dInj Date and Time 08-OCT-2012 2224Instrument ID PESTGC9iClient ID Compound 27 Aroclor-1260CAS 11096-82-5Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 776

Manual Integration Results

RT 771

Response 26515963

Amount 111428

Conc 74000

Manually Integrated By diazcManual Integration Reason

10162012Page 298 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1309972-A

Matrix vr479497dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2224

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 483

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 573

RECCAS NO LIMITSQSURROGATE

91 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 299 of 323

Data File vr479497d Page 1 Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479497dLab Smp Id LCS 460-1309972-a Inj Date 08-OCT-2012 2224 Operator Inst ID PESTGC9iSmp Info LCS 460-1309972-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 25 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2058 2085 -0027 15080112 945502 630 8000- 12000 10000(M)

2502 2527 -0025 26928755 988901 660 13324- 19985 17857

2750 2777 -0027 19042665 106070 710 9975- 14963 12628

3103 3130 -0027 59594211 100167 670 29367- 44051 39518

3301 3330 -0029 23808984 103998 690 11758- 17638 15788

3694 3685 0009 14297782 603352 400 11464- 17196 9481

4013 4043 -0030 24245185 108176 720 11819- 17728 16078

4188 4191 -0003 10255607 100963 670 5577- 8366 6801

Average of Peak Concentrations = 640

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6048 6072 -0024 36196886 110771 740 8000- 12000 10000

10162012Page 300 of 323

Data File vr479497d Page 2 Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6500 6522 -0022 67525585 111673 740 14654- 21981 18655

6943 6964 -0021 64479188 116279 780 14108- 21162 17813

7142 7165 -0023 33072749 109644 730 7567- 11351 9137

7578 7602 -0024 30577540 112984 750 7053- 10579 8448

8864 8893 -0029 38421619 111797 740 9199- 13799 10615

9083 9115 -0032 26202367 123818 820 5953- 8930 7239

10138 10153 -0015 20706585 120073 800 4647- 6971 5721

Average of Peak Concentrations = 760

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 42991277 913346 61 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 301 of 323

Data File vr479497d

Date 08-OCT-2012 2224

Client ID Instrument PESTGC9i

Sample Info LCS 460-1309972-a Operator

10162012Page 302 of 323

Manual Integration Report

Data File vr479497dInj Date and Time 08-OCT-2012 2224Instrument ID PESTGC9iClient ID Compound 21 Aroclor-1016CAS 12674-11-2Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 208

Manual Integration Results

RT 206

Response 15080112

Amount 96644

Conc 64000

Manually Integrated By diazcManual Integration Reason

10162012Page 303 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCSD 460-1309973-A

Matrix vf479498dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2239

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 516

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 583

RECCAS NO LIMITSQSURROGATE

99 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 304 of 323

Data File vf479498d Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479498dLab Smp Id LCSd 460-1309973-a Inj Date 08-OCT-2012 2239 Operator Inst ID PESTGC9iSmp Info LCSd 460-1309973-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 26 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2925 2961 -0036 10994509 107027 710 8000- 12000 10000

3594 3641 -0047 24222192 114726 760 16892- 25338 22031

4039 4085 -0046 9969671 114410 760 6889- 10334 9068

4435 4479 -0044 43128755 114369 760 30481- 45721 39228

4680 4722 -0042 19946065 121217 810 13320- 19980 18142

5177 5158 0019 7960960 814816 540 7564- 11346 7241

5569 5542 0027 6392667 533166 360 9332- 13998 5814

5711 5752 -0041 14546887 119763 800 9784- 14675 13231

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7708 7756 -0048 27193660 123013 820 8000- 12000 10000(M)

10162012Page 305 of 323

Data File vf479498d Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8164 8215 -0051 30632211 122078 810 9103- 13655 11264

9022 9084 -0062 47541251 128955 860 14090- 21136 17482

9278 9332 -0054 21062846 129693 860 6105- 9158 7745

9404 9454 -0050 11787377 133728 890 3460- 5190 4335

9862 9901 -0039 21547760 127309 850 6444- 9666 7924

10618 10616 0002 10677528 506919 340 7926- 11889 3926

11062 11086 -0024 9277293 118074 790 2968- 4452 3412

Average of Peak Concentrations = 780

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11482 11515 -0033 26307958 989158 66 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 306 of 323

Data File vf479498d

Date 08-OCT-2012 2239

Client ID Instrument PESTGC9i

Sample Info LCSd 460-1309973-a Operator

10162012Page 307 of 323

Manual Integration Report

Data File vf479498dInj Date and Time 08-OCT-2012 2239Instrument ID PESTGC9iClient ID Compound 27 Aroclor-1260CAS 11096-82-5Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 776

Manual Integration Results

RT 771

Response 27193660

Amount 116693

Conc 78000

Manually Integrated By diazcManual Integration Reason

10162012Page 308 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCSD 460-1309973-A

Matrix vr479498dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2239

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 497

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 595

RECCAS NO LIMITSQSURROGATE

108 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 309 of 323

Data File vr479498d Page 1 Report Date 09-Oct-2012 0321

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479498dLab Smp Id LCSd 460-1309973-a Inj Date 08-OCT-2012 2239 Operator Inst ID PESTGC9iSmp Info LCSd 460-1309973-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 26 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2058 2085 -0027 15401465 965650 640 8000- 12000 10000(M)

2501 2527 -0026 27477458 100905 670 13324- 19985 17841

2750 2777 -0027 19458638 108387 720 9975- 14963 12634

3102 3130 -0028 60672366 101979 680 29367- 44051 39394

3299 3330 -0031 24206974 105737 700 11758- 17638 15717

3679 3685 -0006 17478185 737562 490 11464- 17196 11348

4012 4043 -0031 24592091 109724 730 11819- 17728 15967

4189 4191 -0002 9970290 981538 650 5577- 8366 6474

Average of Peak Concentrations = 660

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6047 6072 -0025 36957605 113099 750 8000- 12000 10000

10162012Page 310 of 323

Data File vr479498d Page 2 Report Date 09-Oct-2012 0321

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6498 6522 -0024 69036402 114172 760 14654- 21981 18680

6940 6964 -0024 66037968 119090 790 14108- 21162 17869

7140 7165 -0025 33956993 112575 750 7567- 11351 9188

7575 7602 -0027 31643763 116923 780 7053- 10579 8562

8861 8893 -0032 40016219 116437 780 9199- 13799 10828

9080 9115 -0035 27744305 131104 870 5953- 8930 7507

10136 10153 -0017 22040150 127806 850 4647- 6971 5964

Average of Peak Concentrations = 790

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10612 10624 -0012 50942327 108226 72 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 311 of 323

Data File vr479498d

Date 08-OCT-2012 2239

Client ID Instrument PESTGC9i

Sample Info LCSd 460-1309973-a Operator

10162012Page 312 of 323

Manual Integration Report

Data File vr479498dInj Date and Time 08-OCT-2012 2239Instrument ID PESTGC9iClient ID Compound 21 Aroclor-1016CAS 12674-11-2Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 208

Manual Integration Results

RT 206

Response 15401465

Amount 99401

Conc 66000

Manually Integrated By diazcManual Integration Reason

10162012Page 313 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GC SEMI VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

PESTGC9

129926

Start Date

End Date 09302012 2043

09302012 1530

RINSE 460-1299261 CLP-2 053(mm)109302012 1530

RINSE 460-1299261 CLP-1 053(mm)109302012 1530

RINSE 460-1299262 CLP-2 053(mm)109302012 1546

RINSE 460-1299262 CLP-1 053(mm)109302012 1546

ZZZZZ CLP-2 053(mm)109302012 1602

ZZZZZ CLP-1 053(mm)109302012 1602

ZZZZZ CLP-2 053(mm)109302012 1617

ZZZZZ CLP-1 053(mm)109302012 1617

ZZZZZ CLP-2 053(mm)109302012 1633

ZZZZZ CLP-1 053(mm)109302012 1633

ZZZZZ CLP-2 053(mm)109302012 1649

ZZZZZ CLP-1 053(mm)109302012 1649

IC 460-1299267 CLP-2 053(mm)109302012 1704 vf479200d

IC 460-1299267 CLP-1 053(mm)109302012 1704 vr479200d

IC 460-1299268 CLP-2 053(mm)109302012 1720 vf479201d

IC 460-1299268 CLP-1 053(mm)109302012 1720 vr479201d

IC 460-1299269 CLP-2 053(mm)109302012 1735 vf479202d

IC 460-1299269 CLP-1 053(mm)109302012 1735 vr479202d

IC 460-12992610 CLP-2 053(mm)109302012 1751 vf479203d

IC 460-12992610 CLP-1 053(mm)109302012 1751 vr479203d

IC 460-12992611 CLP-2 053(mm)109302012 1807 vf479204d

IC 460-12992611 CLP-1 053(mm)109302012 1807 vr479204d

IC 460-12992612 CLP-2 053(mm)109302012 1822 vf479205d

IC 460-12992612 CLP-1 053(mm)109302012 1822 vr479205d

IC 460-12992613 CLP-2 053(mm)109302012 1838 vf479206d

IC 460-12992613 CLP-1 053(mm)109302012 1838 vr479206d

IC 460-12992614 CLP-2 053(mm)109302012 1854 vf479207d

IC 460-12992614 CLP-1 053(mm)109302012 1854 vr479207d

IC 460-12992615 CLP-2 053(mm)109302012 1909 vf479208d

IC 460-12992615 CLP-1 053(mm)109302012 1909 vr479208d

IC 460-12992616 CLP-2 053(mm)109302012 1925 vf479209d

IC 460-12992616 CLP-1 053(mm)109302012 1925 vr479209d

IC 460-12992617 CLP-2 053(mm)109302012 1940

IC 460-12992617 CLP-1 053(mm)109302012 1940

IC 460-12992618 CLP-2 053(mm)109302012 1956

IC 460-12992618 CLP-1 053(mm)109302012 1956

ZZZZZ CLP-2 053(mm)109302012 2011

ZZZZZ CLP-1 053(mm)109302012 2011

ZZZZZ CLP-2 053(mm)109302012 2027

ZZZZZ CLP-1 053(mm)109302012 2027

ZZZZZ CLP-2 053(mm)109302012 2043

ZZZZZ CLP-1 053(mm)109302012 2043

8082

10162012Page 314 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GC SEMI VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

PESTGC9

131137

Start Date

End Date 10092012 0147

10082012 1814

PIBLK 460-1311371 CLP-2 053(mm)110082012 1814 vf479492d

PIBLK 460-1311371 CLP-1 053(mm)110082012 1814 vr479492d

CCVRT 460-1311372 CLP-2 053(mm)110082012 1830 vf479493d

CCVRT 460-1311372 CLP-1 053(mm)110082012 1830 vr479493d

ZZZZZ CLP-2 053(mm)110082012 2137

ZZZZZ CLP-1 053(mm)110082012 2137

ZZZZZ CLP-2 053(mm)110082012 2152

ZZZZZ CLP-1 053(mm)110082012 2152

MB 460-1309971-A CLP-2 053(mm)110082012 2208 vf479496d

MB 460-1309971-A CLP-1 053(mm)110082012 2208 vr479496d

LCS 460-1309972-A CLP-2 053(mm)110082012 2224 vf479497d

LCS 460-1309972-A CLP-1 053(mm)110082012 2224 vr479497d

LCSD 460-1309973-A CLP-2 053(mm)110082012 2239 vf479498d

LCSD 460-1309973-A CLP-1 053(mm)110082012 2239 vr479498d

ZZZZZ CLP-2 053(mm)110082012 2255

ZZZZZ CLP-1 053(mm)110082012 2255

ZZZZZ CLP-2 053(mm)110082012 2311

ZZZZZ CLP-1 053(mm)110082012 2311

ZZZZZ CLP-2 053(mm)110082012 2326

ZZZZZ CLP-1 053(mm)110082012 2326

ZZZZZ CLP-2 053(mm)110082012 2342

ZZZZZ CLP-1 053(mm)110082012 2342

ZZZZZ CLP-2 053(mm)110082012 2358

ZZZZZ CLP-1 053(mm)110082012 2358

ZZZZZ CLP-2 053(mm)110092012 0013

ZZZZZ CLP-1 053(mm)110092012 0013

460-45537-1 WC-17338-100512-MW14-MM-251

CLP-2 053(mm)110092012 0029 vf479505d

460-45537-1 WC-17338-100512-MW14-MM-251

CLP-1 053(mm)110092012 0029 vr479505d

460-45537-2 WC-17338-100512-MW101-MM-252

CLP-2 053(mm)110092012 0045 vf479506d

460-45537-2 WC-17338-100512-MW101-MM-252

CLP-1 053(mm)110092012 0045 vr479506d

ZZZZZ CLP-2 053(mm)110092012 0100

ZZZZZ CLP-1 053(mm)110092012 0100

ZZZZZ CLP-2 053(mm)110092012 0116

ZZZZZ CLP-1 053(mm)110092012 0116

PIBLK 460-13113718 CLP-2 053(mm)110092012 0131 vf479509d

PIBLK 460-13113718 CLP-1 053(mm)110092012 0131 vr479509d

CCV 460-13113719 CLP-2 053(mm)110092012 0147 vf479510d

CCV 460-13113719 CLP-1 053(mm)110092012 0147 vr479510d

8082

10162012Page 315 of 323

10162012Page 316 of 323

10162012Page 317 of 323

10162012Page 318 of 323

10162012Page 319 of 323

Lab Name Job No

SDG No

GC SEMI VOA BATCH WORKSHEET

460-45537-1

Batch Number Batch AnalystBatch Start Date

Batch End Date

Wu Huachi

100812 1800

100812 0754130997

Batch Method

TestAmerica Edison

3510C

Lab Sample ID Client Sample ID Method Chain Basis ReceivedpH InitialAmount FinalAmount OP_PCBSP 00024 OPPSTPCBSU 00021

AnalysisComment

7 1000 mL 5 mL 50 uL Acid Cleaning_UP

MB 460-1309971 3510C 8082

7 1000 mL 5 mL 50 uL 50 uL Acid Cleaning_UP

LCS 460-1309972

3510C 8082

7 1000 mL 5 mL 50 uL 50 uL Acid Cleaning_UP

LCSD 460-1309973

3510C 8082

WC-17338-100512-MW14-MM-251

7 980 mL 5 mL 50 uL Acid Cleaning_UP

460-45537-E-1 3510C 8082 T

WC-17338-100512-MW101-MM-252

7 990 mL 5 mL 50 uL Acid Cleaning_UP

460-45537-E-2 3510C 8082 T

Batch Notes

Batch Comment 8082Acid Cleaning_up Lot 20042

Persons name who did the concentration Wuh

Exchange Solvent Lot 6383

Exchange Solvent Name Hexane

Final Concentrator Volume 5 mL

N-evap temperature 35 Degrees C

Na2SO4 Lot Number 213204

Prep Solvent Lot 14764

Prep Solvent Name Mecl2

Prep Solvent Volume Used 180 ml mL

Persons name who did the prep Wuh

Persons name who witnessed reagent drop HCP

Basis Basis Description

T TotalNA

Page 1 of 18082

10162012Page 320 of 323

Shipping and

Receiving

Documents

10162012Page 321 of 323

10162012Page 322 of 323

Login Sample Receipt Checklist

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Login Number 45537

Question Answer Comment

Creator Hall Alonzo

List Source TestAmerica Edison

List Number 1

NARadioactivity wasnt checked or is lt= background as measured by a survey

meter

NAThe coolers custody seal if present is intact Not present

TrueSample custody seals if present are intact

TrueThe cooler or samples do not appear to have been compromised or

tampered with

TrueSamples were received on ice

TrueCooler Temperature is acceptable

TrueCooler Temperature is recorded 32deg C IR 2

TrueCOC is present

TrueCOC is filled out in ink and legible

TrueCOC is filled out with all pertinent information

TrueIs the Field Samplers name present on COC

TrueThere are no discrepancies between the containers received and the COC

TrueSamples are received within Holding Time

TrueSample containers have legible labels

TrueContainers are not broken or leaking

TrueSample collection datetimes are provided

TrueAppropriate sample containers are used

TrueSample bottles are completely filled

TrueSample Preservation Verified

TrueThere is sufficient vol for all requested analyses incl any requested

MSMSDs

TrueContainers requiring zero headspace have no headspace or bubble is

lt6mm (14)

NAMultiphasic samples are not present

NASamples do not require splitting or compositing

NAResidual Chlorine Checked No analysis requiring residual chlorine check

assigned

TestAmerica Edison 10162012Page 323 of 323

  • Cover Title Page
  • Table of Contents
  • Data Summaries
    • Report Narrative
    • Sample Summary
    • Executive Summary
    • Method Summary
    • Method Analyst Summary
    • Sample Datasheets
    • Surrogate Summary
    • QC Data Summary
    • Data Qualifiers
    • QC Association Summary
    • Lab Chronicle
      • Organic Sample Data
        • GCMS VOA
          • Method 8260 DEL
            • Method 8260 DEL QC Summary
            • Method 8260 DEL Sample Data
            • Standards Data
              • Method 8260 DEL ICAL Data
              • Method 8260 DEL CCAL Data
                • Raw QC Data
                  • Method 8260 DEL Tune Data
                  • Method 8260 DEL Blank Data
                  • Method 8260 DEL LCSLCSD Data
                  • Method 8260 DEL MSMSD Data
                    • Method 8260 DEL Run Logs
                    • Method 8260 DEL Prep Data
                        • GC Semi VOA
                          • Method 8082 - Delaware
                            • Method 8082 - Delaware QC Summary
                            • Method 8082 - Delaware Sample Data
                            • Standards Data
                              • Method 8082 - Delaware ICAL Data
                              • Method 8082 - Delaware CCAL Data
                                • Raw QC Data
                                  • Method 8082 - Delaware Blank Data
                                  • Method 8082 - Delaware LCSLCSD Data
                                    • Method 8082 - Delaware Run Logs
                                    • Method 8082 - Delaware Prep Data
                                      • Shipping and Receiving Documents
                                        • Client Chain of Custody
                                        • Sample Receipt Checklist
Page 5: J45537-1 Nj Full Package Final Report

SAMPLE SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample IDLab Sample ID Client Matrix Sampled Received

DateTime DateTime

460-45537-1 WC-17338-100512-MW14-MM-2

51

Water 10052012 1000 10052012 1910

460-45537-2 WC-17338-100512-MW101-MM-

252

Water 10052012 1230 10052012 1910

460-45537-3TB TB-17338-100512-253 Water 10052012 0000 10052012 1910

TestAmerica Edison 10162012Page 5 of 323

EXECUTIVE SUMMARY - Detections

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Analyte Result

Reporting

Limit Units Method

Lab Sample ID Client Sample ID

Qualifier

460-45537-1 WC-17338-100512-MW14-MM-251

10 ugL 8260B017 JMethyl tert-butyl ether

10 ugL 8260B017 JToluene

10 ugL 8260B028 JTetrachloroethene

460-45537-2 WC-17338-100512-MW101-MM-252

10 ugL 8260B020 JMethyl tert-butyl ether

460-45537-3TB TB-17338-100512-253

10 ugL 8260B074 JMethylene Chloride

10 ugL 8260B0096 JChloroform

TestAmerica Edison 10162012Page 6 of 323

METHOD SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Preparation MethodMethodLab LocationDescription

Matrix Water

Volatile Organics (GCMS) TAL EDI SW846 8260B

Purge and Trap TAL EDI SW846 5030B

Polychlorinated Biphenyls (PCBs) (GC) TAL EDI SW846 8082

Liquid-Liquid Extraction (Separatory Funnel) TAL EDI SW846 3510C

Lab References

TAL EDI = TestAmerica Edison

Method References

SW846 = Test Methods For Evaluating Solid Waste PhysicalChemical Methods Third Edition November 1986 And Its Updates

TestAmerica Edison 10162012Page 7 of 323

METHOD ANALYST SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Method Analyst Analyst ID

Boykin Kenneth KBSW846 8260B

Boykin Carol B CBBSW846 8082

TestAmerica Edison

10162012Page 8 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

017 J 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

017 J 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

028 J 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 9 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

99 70 - 1304-Bromofluorobenzene

96 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 10 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 11 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

020 J 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 12 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

98 70 - 1304-Bromofluorobenzene

97 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 13 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 14 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

074 J 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

014 U 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0096 J 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 15 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

99 70 - 1304-Bromofluorobenzene

97 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 16 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 17 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0029

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type PRIMARY

980 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

013 U 051013PCB-1016

029 U 051029PCB-1221

012 U 051012PCB-1232

012 U 051012PCB-1242

024 U 051024PCB-1248

017 U 051017PCB-1254

015 U 051015PCB-1260

Surrogate Rec Acceptance LimitsQualifier

83 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 18 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0029

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type SECONDARY

980 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Surrogate Rec Acceptance LimitsQualifier

82 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 19 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0045

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type PRIMARY

990 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

013 U 051013PCB-1016

028 U 051028PCB-1221

012 U 051012PCB-1232

012 U 051012PCB-1242

024 U 051024PCB-1248

017 U 051017PCB-1254

015 U 051015PCB-1260

Surrogate Rec Acceptance LimitsQualifier

52 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 20 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0045

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type SECONDARY

990 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Surrogate Rec Acceptance LimitsQualifier

50 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 21 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Surrogate Recovery Report

8260B Volatile Organics (GCMS)

Client Matrix Water

Lab Sample ID Client Sample ID

DCA TOL BFB

Rec Rec Rec

460-45537-1 WC-17338-100512-M

W14-MM-251

97 96 99

460-45537-2 WC-17338-100512-M

W101-MM-252

97 97 98

460-45537-3 TB-17338-100512-25

3

97 97 99

MB 460-1316564 99 96 95

LCS 460-1316563 96 99 97

460-45537-2 MS WC-17338-100512-M

W101-MM-252 MS

96 99 99

460-45537-2 MSD WC-17338-100512-M

W101-MM-252 MSD

96 99 97

Surrogate Acceptance Limits

DCA = 12-Dichloroethane-d4 (Surr) 70-130

TOL = Toluene-d8 (Surr) 70-130

BFB = 4-Bromofluorobenzene 70-130

TestAmerica Edison

10162012Page 22 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Surrogate Recovery Report

8082 Polychlorinated Biphenyls (PCBs) (GC)

Client Matrix Water

Lab Sample ID Client Sample ID

DCB1 DCB2

Rec Rec

460-45537-1 WC-17338-100512-M

W14-MM-251

82 83

460-45537-2 WC-17338-100512-M

W101-MM-252

52 50

MB 460-1309971-A 97 88

LCS 460-1309972-A 91 84

LCSD

460-1309973-A

108 99

Surrogate Acceptance Limits

DCB = DCB Decachlorobiphenyl 37-150

TestAmerica Edison

10162012Page 23 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-131656

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08981d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5MB 460-1316564

Analysis Date 10112012 2247

Analysis Batch

Prep Batch

Leach Batch

NA

NA

460-131656

Prep Date

Leach Date

10112012 2247

NA

Analyte RLMDLQualResult

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

014 U 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

TestAmerica Edison 10162012Page 24 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-131656

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08981d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5MB 460-1316564

Analysis Date 10112012 2247

Analysis Batch

Prep Batch

Leach Batch

NA

NA

460-131656

Prep Date

Leach Date

10112012 2247

NA

Analyte RLMDLQualResult

014 U 1001413-Dichlorobenzene

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance Limits

12-Dichloroethane-d4 (Surr) 99 70 - 130

4-Bromofluorobenzene 95 70 - 130

Toluene-d8 (Surr) 96 70 - 130

Method Blank TICs- Batch 460-131656

Cas Number Analyte RT Est Result Qual

Tentatively Identified Compound None

TestAmerica Edison 10162012Page 25 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10

Lab Control Sample - Batch 460-131656

Client Matrix

Lab Sample ID

Dilution

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08977d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5LCS 460-1316563

Analysis Date 10112012 2113

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Prep Date

Leach Date

10112012 2113

NA

Analyte QualLimit RecResultSpike Amount

200 210 105 74 - 128111-Trichloroethane

200 181 90 46 - 145Dichlorodifluoromethane

200 210 105 58 - 146Chloromethane

200 203 101 61 - 144Vinyl chloride

200 211 105 55 - 153Bromomethane

200 222 111 70 - 11612-Dibromo-3-Chloropropane

200 209 104 82 - 12212-Dichlorobenzene

200 190 95 69 - 147Trichlorofluoromethane

200 223 112 56 - 13911-Dichloroethene

200 211 106 80 - 12012-Dichloropropane

200 203 102 47 - 139112-Trichloro-122-trifluoroethane

200 250 125 45 - 156Acetone

200 218 109 58 - 139Carbon disulfide

200 220 110 50 - 151Methyl acetate

200 200 100 79 - 119Methylene Chloride

200 216 108 75 - 122trans-12-Dichloroethene

200 217 109 80 - 120Chlorodibromomethane

200 207 104 71 - 115Methyl tert-butyl ether

200 201 101 69 - 145Chloroethane

200 204 102 78 - 12211-Dichloroethane

200 211 106 80 - 120cis-12-Dichloroethene

200 214 107 65 - 1142-Butanone (MEK)

200 205 103 82 - 123Chloroform

200 206 103 79 - 126Ethylbenzene

200 208 104 58 - 133Cyclohexane

200 211 105 73 - 120Carbon tetrachloride

200 212 106 83 - 124Benzene

200 204 102 74 - 11812-Dichloroethane

200 212 106 78 - 119Trichloroethene

200 215 107 61 - 129Methylcyclohexane

200 214 107 79 - 119Dichlorobromomethane

200 216 108 80 - 120cis-13-Dichloropropene

200 214 107 53 - 1204-Methyl-2-pentanone (MIBK)

200 205 103 80 - 120Toluene

200 215 108 78 - 118trans-13-Dichloropropene

200 217 109 79 - 119112-Trichloroethane

200 210 105 68 - 139Tetrachloroethene

200 201 100 53 - 1212-Hexanone

200 215 107 78 - 11812-Dibromoethane

200 206 103 81 - 121Chlorobenzene

600 612 102 76 - 121Xylenes Total

200 207 104 69 - 112Styrene

200 217 109 73 - 123Bromoform

200 207 104 80 - 125Isopropylbenzene

200 210 105 74 - 1261122-Tetrachloroethane

200 204 102 81 - 12613-Dichlorobenzene

TestAmerica Edison 10162012Page 26 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10

Lab Control Sample - Batch 460-131656

Client Matrix

Lab Sample ID

Dilution

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08977d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5LCS 460-1316563

Analysis Date 10112012 2113

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Prep Date

Leach Date

10112012 2113

NA

Analyte QualLimit RecResultSpike Amount

200 204 102 83 - 12314-Dichlorobenzene

200 220 110 66 - 120124-Trichlorobenzene

Surrogate Rec Acceptance Limits

12-Dichloroethane-d4 (Surr) 96 70 - 130

4-Bromofluorobenzene 97 70 - 130

Toluene-d8 (Surr) 99 70 - 130

TestAmerica Edison 10162012Page 27 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Water

50

50

Client Matrix

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Client Matrix Water

e08985d

5 mL

5 mL

e08986d

5 mL

5 mL

Method 8260B

Preparation 5030B

VOAMS5

VOAMS5

460-45537-2

460-45537-2

MS Lab Sample ID

MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

10122012 0051

NA

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

10122012 0027

Analyte RPD LimitRPDLimit

Rec

MS MSD MS Qual MSD Qual

103 106 74 - 128 3 30111-Trichloroethane

87 90 46 - 145 4 30Dichlorodifluoromethane

102 101 58 - 146 0 30Chloromethane

104 105 61 - 144 0 30Vinyl chloride

107 105 55 - 153 2 30Bromomethane

121 121 70 - 116 0 30 F F12-Dibromo-3-Chloropropane

107 111 82 - 122 3 3012-Dichlorobenzene

121 100 69 - 147 19 30Trichlorofluoromethane

108 119 56 - 139 9 3011-Dichloroethene

111 110 80 - 120 0 3012-Dichloropropane

102 111 47 - 139 8 30112-Trichloro-122-trifluoroethane

99 101 45 - 156 2 30Acetone

113 119 58 - 139 5 30Carbon disulfide

100 101 50 - 151 1 30Methyl acetate

106 106 79 - 119 0 30Methylene Chloride

106 108 75 - 122 2 30trans-12-Dichloroethene

116 118 80 - 120 2 30Chlorodibromomethane

114 116 71 - 115 1 30 FMethyl tert-butyl ether

116 105 69 - 145 10 30Chloroethane

104 111 78 - 122 7 3011-Dichloroethane

105 109 80 - 120 4 30cis-12-Dichloroethene

111 114 65 - 114 3 302-Butanone (MEK)

108 113 82 - 123 4 30Chloroform

107 111 79 - 126 3 30Ethylbenzene

108 117 58 - 133 7 30Cyclohexane

105 110 73 - 120 5 30Carbon tetrachloride

106 114 83 - 124 7 30Benzene

107 109 74 - 118 2 3012-Dichloroethane

107 113 78 - 119 5 30Trichloroethene

115 121 61 - 129 5 30Methylcyclohexane

113 116 79 - 119 3 30Dichlorobromomethane

109 115 80 - 120 5 30cis-13-Dichloropropene

111 114 53 - 120 3 304-Methyl-2-pentanone (MIBK)

TestAmerica Edison 10162012Page 28 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Water

50

50

Client Matrix

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Client Matrix Water

e08985d

5 mL

5 mL

e08986d

5 mL

5 mL

Method 8260B

Preparation 5030B

VOAMS5

VOAMS5

460-45537-2

460-45537-2

MS Lab Sample ID

MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

10122012 0051

NA

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

10122012 0027

Analyte RPD LimitRPDLimit

Rec

MS MSD MS Qual MSD Qual

106 111 80 - 120 5 30Toluene

113 119 78 - 118 5 30 Ftrans-13-Dichloropropene

112 116 79 - 119 3 30112-Trichloroethane

110 116 68 - 139 5 30Tetrachloroethene

109 111 53 - 121 2 302-Hexanone

116 117 78 - 118 1 3012-Dibromoethane

107 111 81 - 121 3 30Chlorobenzene

106 110 76 - 121 3 30Xylenes Total

107 110 69 - 112 3 30Styrene

115 114 73 - 123 1 30Bromoform

107 111 80 - 125 4 30Isopropylbenzene

115 116 74 - 126 0 301122-Tetrachloroethane

106 110 81 - 126 4 3013-Dichlorobenzene

106 110 83 - 123 4 3014-Dichlorobenzene

110 119 66 - 120 8 30124-Trichlorobenzene

Surrogate Acceptance LimitsMS Rec MSD Rec

12-Dichloroethane-d4 (Surr) 96 96 70 - 130

4-Bromofluorobenzene 99 97 70 - 130

Toluene-d8 (Surr) 99 99 70 - 130

TestAmerica Edison 10162012Page 29 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10122012 0027 10122012 0051

Dilution Dilution50 50

Client Matrix Client Matrix Water

Method 8260B

Preparation 5030B

Units ugL460-45537-2 460-45537-2MS Lab Sample ID MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

Analysis Date

Prep Date

Leach Date

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

NA

Amount

Sample

Analyte ResultQual Amount ResultQual ResultQual

MS MSDMS Spike MSD Spike

0060 U 100 100 103 106111-Trichloroethane

022 U 100 100 865 896Dichlorodifluoromethane

010 U 100 100 102 101Chloromethane

014 U 100 100 104 105Vinyl chloride

018 U 100 100 107 105Bromomethane

040 U 100 100 121 121F F12-Dibromo-3-Chloropropane

021 U 100 100 107 11112-Dichlorobenzene

015 U 100 100 121 997Trichlorofluoromethane

0090 U 100 100 108 11911-Dichloroethene

0090 U 100 100 111 11012-Dichloropropane

0080 U 100 100 102 111112-Trichloro-122-trifluoroethane

27 U 100 100 986 101Acetone

013 U 100 100 113 119Carbon disulfide

034 U 100 100 100 101Methyl acetate

018 U 100 100 106 106Methylene Chloride

013 U 100 100 106 108trans-12-Dichloroethene

020 U 100 100 116 118Chlorodibromomethane

020 J 100 100 114 116 FMethyl tert-butyl ether

017 U 100 100 116 105Chloroethane

013 U 100 100 104 11111-Dichloroethane

018 U 100 100 105 109cis-12-Dichloroethene

23 U 100 100 111 1142-Butanone (MEK)

0080 U 100 100 108 113Chloroform

010 U 100 100 107 111Ethylbenzene

016 U 100 100 108 117Cyclohexane

0060 U 100 100 105 110Carbon tetrachloride

0080 U 100 100 106 114Benzene

019 U 100 100 107 10912-Dichloroethane

0090 U 100 100 107 113Trichloroethene

014 U 100 100 115 121Methylcyclohexane

012 U 100 100 113 116Dichlorobromomethane

018 U 100 100 109 115cis-13-Dichloropropene

099 U 100 100 111 1144-Methyl-2-pentanone (MIBK)

015 U 100 100 106 111Toluene

024 U 100 100 113 119 Ftrans-13-Dichloropropene

019 U 100 100 112 116112-Trichloroethane

010 U 100 100 110 116Tetrachloroethene

050 U 100 100 109 1112-Hexanone

028 U 100 100 116 11712-Dibromoethane

011 U 100 100 107 111Chlorobenzene

036 U 300 300 318 329Xylenes Total

012 U 100 100 107 110Styrene

019 U 100 100 115 114Bromoform

TestAmerica Edison 10162012Page 30 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10122012 0027 10122012 0051

Dilution Dilution50 50

Client Matrix Client Matrix Water

Method 8260B

Preparation 5030B

Units ugL460-45537-2 460-45537-2MS Lab Sample ID MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

Analysis Date

Prep Date

Leach Date

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

NA

Amount

Sample

Analyte ResultQual Amount ResultQual ResultQual

MS MSDMS Spike MSD Spike

0080 U 100 100 107 111Isopropylbenzene

016 U 100 100 115 1161122-Tetrachloroethane

014 U 100 100 106 11013-Dichlorobenzene

023 U 100 100 106 11014-Dichlorobenzene

034 U 100 100 110 119124-Trichlorobenzene

TestAmerica Edison 10162012Page 31 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-130997

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

vr479496d

1000 mL

5 mLUnits ugL

Method 8082

Preparation 3510C

PESTGC9MB 460-1309971-A

Analysis Date 10082012 2208

Analysis Batch

Prep Batch

Leach Batch NA

460-131137

460-130997

Prep Date Injection Volume

Leach Date

10082012 0755

NA PRIMARYColumn ID

Analyte RLMDLQualResult

013 U 050013PCB-1016

028 U 050028PCB-1221

012 U 050012PCB-1232

012 U 050012PCB-1242

024 U 050024PCB-1248

017 U 050017PCB-1254

015 U 050015PCB-1260

Surrogate Rec Acceptance Limits

DCB Decachlorobiphenyl 97 37 - 150

Surrogate Rec Acceptance Limits

DCB Decachlorobiphenyl 88 37 - 150

TestAmerica Edison 10162012Page 32 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Lab Control Sample

Lab Control Sample Duplicate Recovery Report - Batch 460-130997

10

10

Water

LCS Lab Sample ID

LCSD Lab Sample ID

Client Matrix

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

Client Matrix Water

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

ugL

vf479497d

1000 mL

5 mL

PRIMARY

vf479498d

1000 mL

5 mL

PRIMARY

ugL

Method 8082

Preparation 3510C

PESTGC9

PESTGC9

LCS 460-1309972-A

LCSD 460-1309973-A

Analysis Date

Prep Date

Leach Date

10082012 2224

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

Rec

103101 71 - 126 2 30PCB-1016

119115 73 - 130 4 30PCB-1260

Surrogate LCS Rec LCSD Rec Acceptance Limits

DCB Decachlorobiphenyl 91 108 37 - 150

Dilution

Dilution

Lab Control Sample

Lab Control Sample Duplicate Recovery Report - Batch 460-130997

10

10

Water

LCS Lab Sample ID

LCSD Lab Sample ID

Client Matrix

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

Client Matrix Water

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

ugL

vr479497d

1000 mL

5 mL

SECONDARY

vr479498d

1000 mL

5 mL

SECONDARY

ugL

Method 8082

Preparation 3510C

PESTGC9

PESTGC9

LCS 460-1309972-A

LCSD 460-1309973-A

Analysis Date

Prep Date

Leach Date

10082012 2224

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

Rec

9997 71 - 126 3 30PCB-1016

117111 73 - 130 5 30PCB-1260

Surrogate LCS Rec LCSD Rec Acceptance Limits

DCB Decachlorobiphenyl 84 99 37 - 150

TestAmerica Edison 10162012Page 33 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10082012 2224

Dilution Dilution10 10

Client Matrix

LCSD Lab Sample ID

Client Matrix Water

Laboratory Control

Laboratory Duplicate Data Report - Batch 460-130997

Method 8082

Preparation 3510C

Units ugLLCS 460-1309972-A LCSD 460-1309973-ALCS Lab Sample ID

Analysis Date

Prep Date

Leach Date

10082012 0755

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NANA

LCSD

ResultQual

LCS

ResultQual

LCSD Spike

Amount

LCS Spike

AmountAnalyte

516507500 500PCB-1016

595573500 500PCB-1260

Water

10082012 2224

Dilution Dilution10 10

Client Matrix

LCSD Lab Sample ID

Client Matrix Water

Laboratory Control

Laboratory Duplicate Data Report - Batch 460-130997

Method 8082

Preparation 3510C

Units ugLLCS 460-1309972-A LCSD 460-1309973-ALCS Lab Sample ID

Analysis Date

Prep Date

Leach Date

10082012 0755

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NANA

LCSD

ResultQual

LCS

ResultQual

LCSD Spike

Amount

LCS Spike

AmountAnalyte

497483500 500PCB-1016

583557500 500PCB-1260

TestAmerica Edison 10162012Page 34 of 323

DATA REPORTING QUALIFIERS

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Lab Section Qualifier Description

GCMS VOA

Indicates the analyte was analyzed for but not detectedU

MSMSD Recovery or RPD exceeds the control limitsF

Result is less than the RL but greater than or equal to the MDL and the

concentration is an approximate value

J

GC Semi VOA

Indicates the analyte was analyzed for but not detectedU

TestAmerica Edison 10162012Page 35 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

QC Association Summary

Lab Sample ID Client Sample ID Client Matrix Method Prep Batch

Report

Basis

GCMS VOA

Analysis Batch460-131656

Lab Control Sample Water 8260BLCS 460-1316563 T

Method Blank Water 8260BMB 460-1316564 T

WaterWC-17338-100512-MW14-MM-251 8260B460-45537-1 T

WaterWC-17338-100512-MW101-MM-252 8260B460-45537-2 T

Matrix Spike Water 8260B460-45537-2MS T

Matrix Spike Duplicate Water 8260B460-45537-2MSD T

WaterTB-17338-100512-253 8260B460-45537-3TB T

Report Basis

T = Total

GC Semi VOA

Prep Batch 460-130997

Lab Control Sample Water 3510CLCS 460-1309972-A T

Lab Control Sample Duplicate Water 3510CLCSD 460-1309973-A T

Method Blank Water 3510CMB 460-1309971-A T

WaterWC-17338-100512-MW14-MM-251 3510C460-45537-1 T

WaterWC-17338-100512-MW101-MM-252 3510C460-45537-2 T

Analysis Batch460-131137

Lab Control Sample Water 460-1309978082LCS 460-1309972-A T

Lab Control Sample Duplicate Water 460-1309978082LCSD 460-1309973-A T

Method Blank Water 460-1309978082MB 460-1309971-A T

Water 460-130997WC-17338-100512-MW14-MM-251 8082460-45537-1 T

Water 460-130997WC-17338-100512-MW101-MM-252 8082460-45537-2 T

Report Basis

T = Total

TestAmerica Edison

10162012Page 36 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Laboratory Chronicle

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1000

460-45537-1 WC-17338-100512-MW14-MM-251

P5030B 460-45537-A-1 460-131656 10112012 2341 KBTAL EDI1

A8260B 460-45537-A-1 460-131656 10112012 2341 KBTAL EDI1

P3510C 460-45537-E-1-B 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 460-45537-E-1-B 460-131137 460-130997 10092012 0029 CBBTAL EDI1

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 WC-17338-100512-MW101-MM-252

P5030B 460-45537-A-2 460-131656 10122012 0004 KBTAL EDI1

A8260B 460-45537-A-2 460-131656 10122012 0004 KBTAL EDI1

P3510C 460-45537-E-2-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 460-45537-E-2-A 460-131137 460-130997 10092012 0045 CBBTAL EDI1

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 MS WC-17338-100512-MW101-MM-252

P5030B 460-45537-C-2 MS 460-131656 10122012 0027 KBTAL EDI5

A8260B 460-45537-C-2 MS 460-131656 10122012 0027 KBTAL EDI5

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 MSD WC-17338-100512-MW101-MM-252

P5030B 460-45537-C-2 MSD 460-131656 10122012 0051 KBTAL EDI5

A8260B 460-45537-C-2 MSD 460-131656 10122012 0051 KBTAL EDI5

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 0000

460-45537-3 TB-17338-100512-253

P5030B 460-45537-A-3 460-131656 10112012 2317 KBTAL EDI1

A8260B 460-45537-A-3 460-131656 10112012 2317 KBTAL EDI1

A = Analytical Method P = Prep Method TestAmerica Edison

10162012Page 37 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Laboratory Chronicle

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

MB NA

P5030B MB 460-1316564 460-131656 10112012 2247 KBTAL EDI1

A8260B MB 460-1316564 460-131656 10112012 2247 KBTAL EDI1

P3510C MB 460-1309971-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 MB 460-1309971-A 460-131137 460-130997 10082012 2208 CBBTAL EDI1

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

LCS NA

P5030B LCS 460-1316563 460-131656 10112012 2113 KBTAL EDI1

A8260B LCS 460-1316563 460-131656 10112012 2113 KBTAL EDI1

P3510C LCS 460-1309972-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 LCS 460-1309972-A 460-131137 460-130997 10082012 2224 CBBTAL EDI1

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

LCSD NA

P3510C LCSD

460-1309973-A

460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 LCSD

460-1309973-A

460-131137 460-130997 10082012 2239 CBBTAL EDI1

Lab ReferencesTAL EDI = TestAmerica Edison

A = Analytical Method P = Prep Method TestAmerica Edison

10162012Page 38 of 323

Method 8260 DELVolatile Organics (GCMS) by Method

8260 (Delaware)

10162012Page 39 of 323

FORM II

GCMS VOA SURROGATE RECOVERY

Lab Name Job No 460-45537-1

SDG No

Matrix Water Level Low

TestAmerica Edison

GC Column (1) Rtx-VMS ID 018(mm)

Lab Sample IDClient Sample ID DCA TOL BFB

460-45537-1WC-17338-100512-MW14-MM-251

97 96 99

460-45537-2WC-17338-100512-MW101-MM-252

97 97 98

460-45537-3TB-17338-100512-253

97 97 99

MB 460-1316564 99 96 95

LCS 460-1316563 96 99 97

460-45537-2 MSWC-17338-100512-MW101-MM-252 MS

96 99 99

460-45537-2 MSDWC-17338-100512-MW101-MM-252 MSD

96 99 97

QC LIMITSQC LIMITSDCA = 12-Dichloroethane-d4 (Surr) 70-130

TOL = Toluene-d8 (Surr) 70-130

BFB = 4-Bromofluorobenzene 70-130

FORM II 8260B

Column to be used to flag recovery values

10162012Page 40 of 323

GCMS VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08977dWater

Lab ID LCS 460-1316563 Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

111-Trichloroethane 200 210 74-128105

Dichlorodifluoromethane 200 181 46-14590

Chloromethane 200 210 58-146105

Vinyl chloride 200 203 61-144101

Bromomethane 200 211 55-153105

12-Dibromo-3-Chloropropane 200 222 70-116111

12-Dichlorobenzene 200 209 82-122104

Trichlorofluoromethane 200 190 69-14795

11-Dichloroethene 200 223 56-139112

12-Dichloropropane 200 211 80-120106

112-Trichloro-122-trifluoroethane

200 203 47-139102

Acetone 200 250 45-156125

Carbon disulfide 200 218 58-139109

Methyl acetate 200 220 50-151110

Methylene Chloride 200 200 79-119100

trans-12-Dichloroethene 200 216 75-122108

Chlorodibromomethane 200 217 80-120109

Methyl tert-butyl ether 200 207 71-115104

Chloroethane 200 201 69-145101

11-Dichloroethane 200 204 78-122102

cis-12-Dichloroethene 200 211 80-120106

2-Butanone (MEK) 200 214 65-114107

Chloroform 200 205 82-123103

Ethylbenzene 200 206 79-126103

Cyclohexane 200 208 58-133104

Carbon tetrachloride 200 211 73-120105

Benzene 200 212 83-124106

12-Dichloroethane 200 204 74-118102

Trichloroethene 200 212 78-119106

Methylcyclohexane 200 215 61-129107

Dichlorobromomethane 200 214 79-119107

cis-13-Dichloropropene 200 216 80-120108

4-Methyl-2-pentanone (MIBK) 200 214 53-120107

Toluene 200 205 80-120103

trans-13-Dichloropropene 200 215 78-118108

112-Trichloroethane 200 217 79-119109

Tetrachloroethene 200 210 68-139105

2-Hexanone 200 201 53-121100

12-Dibromoethane 200 215 78-118107

Chlorobenzene 200 206 81-121103

Xylenes Total 600 612 76-121102

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 41 of 323

GCMS VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08977dWater

Lab ID LCS 460-1316563 Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

Styrene 200 207 69-112104

Bromoform 200 217 73-123109

Isopropylbenzene 200 207 80-125104

1122-Tetrachloroethane 200 210 74-126105

13-Dichlorobenzene 200 204 81-126102

14-Dichlorobenzene 200 204 83-123102

124-Trichlorobenzene 200 220 66-120110

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 42 of 323

GCMS VOA MATRIX SPIKE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08985dWater

Lab ID 460-45537-2 MS Client ID WC-17338-100512-MW101-MM-252 MS

TestAmerica Edison

LIMITS

COMPOUND

CONCENTRATION

REC

QC

REC

SAMPLE

CONCENTRATION

SPIKE

ADDED

(ugL) (ugL) (ugL)

MS MS

100 103 74-128111-Trichloroethane 1030060 U

100 865 46-145Dichlorodifluoromethane 87022 U

100 102 58-146Chloromethane 102010 U

100 104 61-144Vinyl chloride 104014 U

100 107 55-153Bromomethane 107018 U

100 121 70-11612-Dibromo-3-Chloropropane 121040 U F

100 107 82-12212-Dichlorobenzene 107021 U

100 121 69-147Trichlorofluoromethane 121015 U

100 108 56-13911-Dichloroethene 1080090 U

100 111 80-12012-Dichloropropane 1110090 U

100 102 47-139112-Trichloro-122-trifluoroethane

1020080 U

100 986 45-156Acetone 9927 U

100 113 58-139Carbon disulfide 113013 U

100 100 50-151Methyl acetate 100034 U

100 106 79-119Methylene Chloride 106018 U

100 106 75-122trans-12-Dichloroethene 106013 U

100 116 80-120Chlorodibromomethane 116020 U

100 114 71-115Methyl tert-butyl ether 114020 J

100 116 69-145Chloroethane 116017 U

100 104 78-12211-Dichloroethane 104013 U

100 105 80-120cis-12-Dichloroethene 105018 U

100 111 65-1142-Butanone (MEK) 11123 U

100 108 82-123Chloroform 1080080 U

100 107 79-126Ethylbenzene 107010 U

100 108 58-133Cyclohexane 108016 U

100 105 73-120Carbon tetrachloride 1050060 U

100 106 83-124Benzene 1060080 U

100 107 74-11812-Dichloroethane 107019 U

100 107 78-119Trichloroethene 1070090 U

100 115 61-129Methylcyclohexane 115014 U

100 113 79-119Dichlorobromomethane 113012 U

100 109 80-120cis-13-Dichloropropene 109018 U

100 111 53-1204-Methyl-2-pentanone (MIBK) 111099 U

100 106 80-120Toluene 106015 U

100 113 78-118trans-13-Dichloropropene 113024 U

100 112 79-119112-Trichloroethane 112019 U

100 110 68-139Tetrachloroethene 110010 U

100 109 53-1212-Hexanone 109050 U

100 116 78-11812-Dibromoethane 116028 U

100 107 81-121Chlorobenzene 107011 U

300 318 76-121Xylenes Total 106036 U

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 43 of 323

GCMS VOA MATRIX SPIKE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08985dWater

Lab ID 460-45537-2 MS Client ID WC-17338-100512-MW101-MM-252 MS

TestAmerica Edison

LIMITS

COMPOUND

CONCENTRATION

REC

QC

REC

SAMPLE

CONCENTRATION

SPIKE

ADDED

(ugL) (ugL) (ugL)

MS MS

100 107 69-112Styrene 107012 U

100 115 73-123Bromoform 115019 U

100 107 80-125Isopropylbenzene 1070080 U

100 115 74-1261122-Tetrachloroethane 115016 U

100 106 81-12613-Dichlorobenzene 106014 U

100 106 83-12314-Dichlorobenzene 106023 U

100 110 66-120124-Trichlorobenzene 110034 U

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 44 of 323

GCMS VOA MATRIX SPIKE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08986dWater

Lab ID 460-45537-2 MSD Client ID WC-17338-100512-MW101-MM-252

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

MSD MSD

100 106 30 74-128111-Trichloroethane 3106

100 896 30 46-145Dichlorodifluoromethane 490

100 101 30 58-146Chloromethane 0101

100 105 30 61-144Vinyl chloride 0105

100 105 30 55-153Bromomethane 2105

100 121 30 70-11612-Dibromo-3-Chloropropane 0121 F

100 111 30 82-12212-Dichlorobenzene 3111

100 997 30 69-147Trichlorofluoromethane 19100

100 119 30 56-13911-Dichloroethene 9119

100 110 30 80-12012-Dichloropropane 0110

100 111 30 47-139112-Trichloro-122-trifluoroethane

8111

100 101 30 45-156Acetone 2101

100 119 30 58-139Carbon disulfide 5119

100 101 30 50-151Methyl acetate 1101

100 106 30 79-119Methylene Chloride 0106

100 108 30 75-122trans-12-Dichloroethene 2108

100 118 30 80-120Chlorodibromomethane 2118

100 116 30 71-115Methyl tert-butyl ether 1116 F

100 105 30 69-145Chloroethane 10105

100 111 30 78-12211-Dichloroethane 7111

100 109 30 80-120cis-12-Dichloroethene 4109

100 114 30 65-1142-Butanone (MEK) 3114

100 113 30 82-123Chloroform 4113

100 111 30 79-126Ethylbenzene 3111

100 117 30 58-133Cyclohexane 7117

100 110 30 73-120Carbon tetrachloride 5110

100 114 30 83-124Benzene 7114

100 109 30 74-11812-Dichloroethane 2109

100 113 30 78-119Trichloroethene 5113

100 121 30 61-129Methylcyclohexane 5121

100 116 30 79-119Dichlorobromomethane 3116

100 115 30 80-120cis-13-Dichloropropene 5115

100 114 30 53-1204-Methyl-2-pentanone (MIBK) 3114

100 111 30 80-120Toluene 5111

100 119 30 78-118trans-13-Dichloropropene 5119 F

100 116 30 79-119112-Trichloroethane 3116

100 116 30 68-139Tetrachloroethene 5116

100 111 30 53-1212-Hexanone 2111

100 117 30 78-11812-Dibromoethane 1117

100 111 30 81-121Chlorobenzene 3111

300 329 30 76-121Xylenes Total 3110

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 45 of 323

GCMS VOA MATRIX SPIKE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08986dWater

Lab ID 460-45537-2 MSD Client ID WC-17338-100512-MW101-MM-252

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

MSD MSD

100 110 30 69-112Styrene 3110

100 114 30 73-123Bromoform 1114

100 111 30 80-125Isopropylbenzene 4111

100 116 30 74-1261122-Tetrachloroethane 0116

100 110 30 81-12613-Dichlorobenzene 4110

100 110 30 83-12314-Dichlorobenzene 4110

100 119 30 66-120124-Trichlorobenzene 8119

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 46 of 323

FORM IV

GCMS VOA METHOD BLANK SUMMARY

Lab Name

SDG No

Job No 460-45537-1TestAmerica Edison

Date Analyzed

GC Column ID

Instrument ID 10112012 2247

Rtx-VMS

NHeated Purge(YN)

VOAMS5

e08981dLab File ID Lab Sample ID MB 460-1316564

WaterMatrix

018(mm)

THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES

LAB SAMPLE ID

LAB

FILE ID DATE ANALYZEDCLIENT SAMPLE ID

10112012 2113e08977dLCS 460-1316563

10112012 2317e08982d460-45537-3TB-17338-100512-253

10112012 2341e08983d460-45537-1WC-17338-100512-MW14-MM-251

10122012 0004e08984d460-45537-2WC-17338-100512-MW101-MM-252

10122012 0027e08985d460-45537-2 MSWC-17338-100512-MW101-MM-252 MS

10122012 0051e08986d460-45537-2 MSDWC-17338-100512-MW101-MM-252 MSD

FORM IV 8260B

10162012Page 47 of 323

FORM V

BROMOFLUOROBENZENE (BFB)

Lab Name

SDG No

Job No 460-45537-1

Lab File ID

Instrument ID

e07834d

VOAMS5

09172012

0324

BFB Injection Date

BFB Injection Time

ME ION ABUNDANCE CRITERIA RELATIVEABUNDANCE

Analysis Batch No 128076

50 150 - 400 of mass 95 219

75 300 - 600 of mass 95 525

95 Base Peak 100 relative abundance 1000

96 50 - 90 of mass 95 64

173 Less than 20 of mass 174 00 (00)1

174 500 - 12000 of mass 95 796

175 50 - 90 of mass 174 66 (83)1

176 950 - 1010 of mass 174 761 (957)1

177 50 - 90 of mass 176 48 (63)2

1-Value is mass 174 2-Value is mass 176

THIS CHECK APPLIES TO THE FOLLOWING SAMPLES MS MSD BLANKS AND STANDARDS

GCMS VOA INSTRUMENT PERFORMANCE CHECK

TestAmerica Edison

CLIENT SAMPLE IDLAB

FILE IDLAB SAMPLE IDDATE

ANALYZEDTIME

ANALYZED

e07836d 09172012 0449IC 460-1280762

e07838d 09172012 0536IC 460-1280763

e07839d 09172012 0600ICIS 460-1280764

e07840d 09172012 0623IC 460-1280765

e07841d 09172012 0646IC 460-1280766

e07842d 09172012 0710IC 460-1280767

FORM V 8260B 10162012Page 48 of 323

FORM V

BROMOFLUOROBENZENE (BFB)

Lab Name

SDG No

Job No 460-45537-1

Lab File ID

Instrument ID

e08975d

VOAMS5

10112012

2008

BFB Injection Date

BFB Injection Time

ME ION ABUNDANCE CRITERIA RELATIVEABUNDANCE

Analysis Batch No 131656

50 150 - 400 of mass 95 218

75 300 - 600 of mass 95 518

95 Base Peak 100 relative abundance 1000

96 50 - 90 of mass 95 65

173 Less than 20 of mass 174 07 (07)1

174 500 - 12000 of mass 95 896

175 50 - 90 of mass 174 72 (80)1

176 950 - 1010 of mass 174 872 (973)1

177 50 - 90 of mass 176 53 (61)2

1-Value is mass 174 2-Value is mass 176

THIS CHECK APPLIES TO THE FOLLOWING SAMPLES MS MSD BLANKS AND STANDARDS

GCMS VOA INSTRUMENT PERFORMANCE CHECK

TestAmerica Edison

CLIENT SAMPLE IDLAB

FILE IDLAB SAMPLE IDDATE

ANALYZEDTIME

ANALYZED

e08976d 10112012 2050CCVIS 460-1316562

e08977d 10112012 2113LCS 460-1316563

e08981d 10112012 2247MB 460-1316564

TB-17338-100512-253 e08982d 10112012 2317460-45537-3

WC-17338-100512-MW14-MM-251

e08983d 10112012 2341460-45537-1

WC-17338-100512-MW101-MM-252

e08984d 10122012 0004460-45537-2

WC-17338-100512-MW101-MM-252 MS

e08985d 10122012 0027460-45537-2 MS

WC-17338-100512-MW101-MM-252 MSD

e08986d 10122012 0051460-45537-2 MSD

e08987d 10122012 0114CCV 460-13165610

FORM V 8260B 10162012Page 49 of 323

GCMS VOA INTERNAL STANDARD AREA AND RETENTION TIME SUMMARY

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVIS 460-1316562 Date Analyzed 10112012 2050

Lab File ID (Standard) e08976d

Instrument ID VOAMS5 GC Column Rtx-VMS ID 018(mm)

Heated Purge (YN) N

Calibration ID 17515

AREA RT AREA RT AREA RT

FB CBZ DCB

UPPER LIMIT

LOWER LIMIT

2625312

656328 578671

2314682

333917

1335668

360 695 10471224 HOUR STD

410

310

745

645

1097

997

1312656 1157341 667834

LAB SAMPLE ID CLIENT SAMPLE ID

LCS 460-1316563 1318918 1146590 683882 360 695 1047

MB 460-1316564 1238441 1084553 638826 360 695 1047

460-45537-3 TB-17338-100512-253 1280000 1135339 646856 359 695 1047

460-45537-1 WC-17338-100512-MW14-MM-251

1242225 1119807 641810 359 695 1047

460-45537-2 WC-17338-100512-MW101-MM-252

1247617 1105330 633816 360 695 1047

460-45537-2 MS WC-17338-100512-MW101-MM-252 MS

1234975 1102789 642491 359 695 1047

460-45537-2 MSD WC-17338-100512-MW101-MM-252 MSD

1296388 1119645 654839 360 695 1047

CCV 460-13165610 1274024 1125053 665092 359 695 1047

FB = Fluorobenzene

CBZ = Chlorobenzene-d5

DCB = 14-Dichlorobenzene-d4

Area Limit = 50-200 of internal standard area

RT Limit = plusmn 05 minutes of internal standard RT

Column used to flag values outside QC limits

FORM VIII 8260B

10162012Page 50 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014J1634-04-4 Methyl tert-butyl ether 017

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015J108-88-3 Toluene 017

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 51 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010J127-18-4 Tetrachloroethene 028

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

96 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 52 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 53 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08983d Report Date 12-Oct-2012 0041

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08983dLab Smp Id 460-45537-A-1 Client Smp ID WC-17338-100512-MW1Inj Date 11-OCT-2012 2341 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-1Misc Info 460-45537-A-1Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 8 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

28 MTBE 73 2016 2022 (0561) 2797 016909 017(a)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 375883 486598 49

52 Fluorobenzene 96 3595 3601 (1000) 1242225 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1240232 479413 48

66 Toluene 91 5162 5162 (0742) 4639 017041 017(a)

71 Tetrachloroethene 166 5582 5582 (0803) 1902 028047 028(a)

78 Chlorobenzene-d5 117 6954 6954 (1000) 1119807 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 516081 495668 50

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 641810 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 54 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

10162012Page 55 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

28 MTBE

10162012Page 56 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

66 Toluene

10162012Page 57 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

71 Tetrachloroethene

10162012Page 58 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014J1634-04-4 Methyl tert-butyl ether 020

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 59 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

98 70-130460-00-4 4-Bromofluorobenzene

97 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 60 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 61 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08984d Report Date 12-Oct-2012 1126

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08984dLab Smp Id 460-45537-A-2 Client Smp ID WC-17338-100512-MW1Inj Date 12-OCT-2012 0004 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-2Misc Info 460-45537-A-2Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 9 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

28 MTBE 73 2016 2022 (0561) 3378 020333 020(a)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 375158 483561 48

52 Fluorobenzene 96 3595 3601 (1000) 1247617 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1243750 487069 49

78 Chlorobenzene-d5 117 6954 6954 (1000) 1105330 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 506189 492299 49

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 633816 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 62 of 323

Data File e08984d

Date 12-OCT-2012 0004

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-2 Operator GCMS VOAMS5

10162012Page 63 of 323

Data File e08984d

Date 12-OCT-2012 0004

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-2 Operator GCMS VOAMS5

28 MTBE

10162012Page 64 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018J75-09-2 Methylene Chloride 074

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014U1634-04-4 Methyl tert-butyl ether 014

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080J67-66-3 Chloroform 0096

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 65 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

97 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 66 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 67 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08982d Report Date 12-Oct-2012 1126

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08982dLab Smp Id 460-45537-A-3 Client Smp ID TB-17338-100512-253Inj Date 11-OCT-2012 2317 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-3Misc Info 460-45537-A-3Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 7 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

22 Methylene Chloride 49 1864 1864 (0518) 6426 073512 074(a)

42 Chloroform 83 2839 2845 (0790) 973 009557 0096(aH)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 385354 484137 48

52 Fluorobenzene 96 3595 3601 (1000) 1280000 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1266759 482968 48

78 Chlorobenzene-d5 117 6954 6954 (1000) 1135339 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 518232 493851 49

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 646856 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

H - Operator selected an alternate compound hit

10162012Page 68 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

10162012Page 69 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

22 Methylene Chloride

10162012Page 70 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

42 Chloroform

10162012Page 71 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1280762 e07836d2Level IC 460-1280763 e07838d3Level ICIS 460-1280764 e07839d4Level IC 460-1280765 e07840d5Level IC 460-1280766 e07841d6Level IC 460-1280767 e07842d

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

Dichlorodifluoromethane 01877 01710 01761 01874 01774 Ave 6501572

01000 30001761

Chloromethane 04585 03624 03717 03896 03503 Ave 13403074

01000 30003733

Vinyl chloride 03440 02904 02965 03157 02914 Ave 10102532

01000 30002985

Bromomethane 01457 01433 01250 01279 01268 Ave 8301184

01000 30001312

Chloroethane 01177 01273 01133 01184 00992 Ave 14300838

01000 30001099

Trichlorofluoromethane 02861 02160 02403 02359 02461 Ave 9902285

01000 30002422

11-Dichloroethene 01607 01355 01549 01479 01528 Ave 5801456

01000 30001496

Carbon disulfide 07031 06470 06825 07347 07283 Ave 5906366

01000 30006887

112-Trichloro-122-trifluoroethane 01346 01631 01661 01849 01887 Ave 11601772

01000 30001691

Methylene Chloride 04479 03769 03581 03500 03182 Ave 14802947

01000 30003576

Acetone 00225 00193 00188 00182 00162 Ave 13800153

01000 30000184

trans-12-Dichloroethene 02047 01989 02141 02174 02016 Ave 4301946

01000 30002052

Methyl acetate 00482 00463 00420 00421 00402 Ave 9400371

01000 30000426

Methyl tert-butyl ether 07109 07281 06924 06817 06907 Ave 6505992

01000 30006838

11-Dichloroethane 04650 04524 04893 04673 04494 Ave 4604257

01000 30004582

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 72 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

cis-12-Dichloroethene 02536 02396 02453 02363 02237 Ave 5602184

01000 30002361

Cyclohexane 03116 04199 04030 04447 04640 Ave 13204438

01000 30004145

Chloroform 03895 04109 04030 04060 03948 Ave 2503851

01000 30003982

Carbon tetrachloride 02420 02373 02793 02813 02930 Ave 9102903

01000 30002705

111-Trichloroethane 03091 03114 03513 03424 03583 Ave 6403522

01000 30003375

2-Butanone (MEK) 00273 00279 00385 00372 00372 Ave 14900364

01000 30000341

Benzene 12012 12533 12592 12117 12284 Ave 8709836

01000 30011896

12-Dichloroethane 03398 03425 03293 03270 03193 Ave 3503124

01000 30003284

Methylcyclohexane 02272 03440 03287 03727 03690 Ave 16303532

01000 30003325

Trichloroethene 02571 02192 02414 02341 02365 Ave 5202426

01000 30002385

12-Dichloropropane 02758 02786 02804 02730 02724 Ave 1202733

01000 30002756

Dichlorobromomethane 03209 03160 03185 03141 03239 Ave 1303237

01000 30003195

cis-13-Dichloropropene 05043 05293 05370 05217 05393 Ave 3105530

01000 30005308

Toluene 13662 13454 14250 13844 13425 Ave 9510731

01000 30013228

Tetrachloroethene 02730 02844 03369 03253 03225 Ave 8303255

01000 30003113

4-Methyl-2-pentanone (MIBK) 03587 03603 03526 03550 03603 Ave 1603692

01000 30003593

trans-13-Dichloropropene 04563 04743 04806 04779 04910 Ave 3805114

01000 30004819

112-Trichloroethane 02303 02327 02287 02201 02185 Ave 2502280

01000 30002264

Chlorodibromomethane 03013 02986 03088 03052 03111 Ave 3003249

01000 30003083

12-Dibromoethane 02596 02708 02743 02671 02629 Ave 2002676

01000 30002670

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 73 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

2-Hexanone 02652 02737 02670 02679 02755 Ave 3202514

01000 30002668

Chlorobenzene 08958 08985 09292 09070 08727 Ave 4008261

01000 30008882

Ethylbenzene 04549 04523 04953 04866 04834 Ave 3704808

01000 30004756

m-Xylene amp p-Xylene 05967 05752 06297 06168 06094 Ave 6505224

01000 30005917

o-Xylene 05732 05675 06142 06014 05989 Ave 3205765

01000 30005886

Bromoform 02053 01991 02150 02194 02258 Ave 4902237

01000 30002147

Styrene 09657 09899 10525 10511 10477 Ave 6408917

01000 30009998

Isopropylbenzene 13314 13509 15606 15346 15340 Ave 10811764

01000 30014146

1122-Tetrachloroethane 06545 06405 06616 06489 06390 Ave 1706330

01000 30006462

13-Dichlorobenzene 12616 12687 13292 13133 12758 Ave 3012242

01000 30012788

14-Dichlorobenzene 13636 13114 13708 13534 13010 Ave 3412550

01000 30013259

12-Dichlorobenzene 12298 12143 12601 12232 11746 Ave 3211521

01000 30012090

12-Dibromo-3-Chloropropane 01290 01163 01082 01109 01042 Ave 7801095

01000 30001130

124-Trichlorobenzene 06538 06139 06311 06265 05725 Ave 5405732

01000 30006118

12-Dichloroethane-d4 (Surr) 02599 02736 02573 02553 02667 Ave 2802702

01000 30002638

Toluene-d8 (Surr) 11377 12027 11720 11573 11645 Ave 1811690

01000 30011672

4-Bromofluorobenzene 07799 08146 08086 08044 08193 Ave 1908206

01000 30008079

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 74 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1280762 e07836dLevel 2 IC 460-1280763 e07838dLevel 3 ICIS 460-1280764 e07839dLevel 4 IC 460-1280765 e07840dLevel 5 IC 460-1280766 e07841dLevel 6 IC 460-1280767 e07842d

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Dichlorodifluoromethane AveFB 8660 39416 167418 450014 17982634551928

100 500 200 500 200500

Chloromethane AveFB 21155 83523 353287 935453 35519068902969

100 500 200 500 200500

Vinyl chloride AveFB 15876 66919 281874 757876 29543837332518

100 500 200 500 200500

Bromomethane AveFB 6723 33032 118799 307121 12855673429373

100 500 200 500 200500

Chloroethane AveFB 5433 29332 107678 284219 10059762426216

100 500 200 500 200500

Trichlorofluoromethane AveFB 13203 49780 228376 566305 24953266618134

100 500 200 500 200500

11-Dichloroethene AveFB 7415 31234 147259 355088 15491024214942

100 500 200 500 200500

Carbon disulfide AveFB 32446 149121 648801 1763903 738404918433408

100 500 200 500 200500

112-Trichloro-122-trifluoroethane

AveFB 6213 37580 157867 443949 19130255130629

100 500 200 500 200500

Methylene Chloride AveFB 20667 86862 340378 840419 32256318533685

100 500 200 500 200500

Acetone AveFB 5188 13342 17849 43750 164598441742

500 150 200 500 200500

trans-12-Dichloroethene AveFB 9445 45844 203500 521911 20443355633771

100 500 200 500 200500

Methyl acetate AveFB 2222 10660 39926 101112 4077131074355

100 500 200 500 200500

Methyl tert-butyl ether AveFB 32806 167790 658123 1636664 700252217351574

100 500 200 500 200500

11-Dichloroethane AveFB 21457 104265 465144 1121930 455634112326764

100 500 200 500 200500

cis-12-Dichloroethene AveFB 11702 55218 233129 567238 22679686324299

100 500 200 500 200500

FORM VI 8260B 10162012Page 75 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Cyclohexane AveFB 14380 96765 383104 1067735 470410312852489

100 500 200 500 200500

Chloroform AveFB 17974 94697 383084 974788 400250611152231

100 500 200 500 200500

Carbon tetrachloride AveFB 11168 54679 265527 675330 29705928405131

100 500 200 500 200500

111-Trichloroethane AveFB 14264 71766 333961 821993 363312510199723

100 500 200 500 200500

2-Butanone (MEK) AveFB 6291 19260 36552 89217 3773171055008

500 150 200 500 200500

Benzene AveCBZ 45050 227079 968083 2380099 986355721876514

100 500 200 500 200500

12-Dichloroethane AveFB 15679 78926 312991 785178 32368389046377

100 500 200 500 200500

Methylcyclohexane AveFB 10486 79279 312424 894738 374094710227785

100 500 200 500 200500

Trichloroethene AveFB 11865 50527 229465 562086 23978387026524

100 500 200 500 200500

12-Dichloropropane AveFB 12728 64209 266559 655380 27621167913672

100 500 200 500 200500

Dichlorobromomethane AveFB 14807 72835 302742 754124 32836079374106

100 500 200 500 200500

cis-13-Dichloropropene AveCBZ 18914 95905 412847 1024782 433022112299317

100 500 200 500 200500

Toluene AveCBZ 51238 243768 1095520 2719268 1077972123868197

100 500 200 500 200500

Tetrachloroethene AveCBZ 10238 51530 258990 639002 25895417239654

100 500 200 500 200500

4-Methyl-2-pentanone (MIBK) AveCBZ 67258 195851 271059 697282 28927468212153

500 150 200 500 200500

trans-13-Dichloropropene AveCBZ 17115 85943 369516 938808 394242511373599

100 500 200 500 200500

112-Trichloroethane AveCBZ 8636 42154 175853 432262 17543015071317

100 500 200 500 200500

Chlorodibromomethane AveCBZ 11301 54107 237421 599464 24982697227226

100 500 200 500 200500

12-Dibromoethane AveCBZ 9735 49066 210900 524614 21107665952425

100 500 200 500 200500

2-Hexanone AveCBZ 49729 148758 205286 526223 22117155590902

500 150 200 500 200500

Chlorobenzene AveCBZ 33596 162793 714336 1781568 700752018374405

100 500 200 500 200500

FORM VI 8260B 10162012Page 76 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Ethylbenzene AveCBZ 17061 81955 380762 955894 388164310693410

100 500 200 500 200500

m-Xylene amp p-Xylene AveCBZ 44761 208423 968280 2423002 978688223238078

200 100 400 100 4001000

o-Xylene AveCBZ 21499 102832 472158 1181273 480921512821590

100 500 200 500 200500

Bromoform AveCBZ 7698 36074 165267 430943 18127954974461

100 500 200 500 200500

Styrene AveCBZ 36217 179367 809158 2064560 841264519831782

100 500 200 500 200500

Isopropylbenzene AveCBZ 49933 244766 1199765 3014281 1231710326165908

100 500 200 500 200500

1122-Tetrachloroethane AveDCB 13823 63947 277413 702309 28987687365342

100 500 200 500 200500

13-Dichlorobenzene AveDCB 26644 126663 557342 1421450 578731414243841

100 500 200 500 200500

14-Dichlorobenzene AveDCB 28798 130929 574816 1464915 590189114602396

100 500 200 500 200500

12-Dichlorobenzene AveDCB 25972 121236 528396 1324016 532862113405399

100 500 200 500 200500

12-Dibromo-3-Chloropropane AveDCB 2725 11615 45388 120062 4727441274610

100 500 200 500 200500

124-Trichlorobenzene AveDCB 13808 61295 264648 678119 25969596669727

100 500 200 500 200500

12-Dichloroethane-d4 (Surr) AveFB 599539 630441 611357 613057 676105782507

500 500 500 500 500500

Toluene-d8 (Surr) AveCBZ 2133452 2179204 2252606 2273339 23375152600040

500 500 500 500 500500

4-Bromofluorobenzene AveDCB 823604 813301 847619 870646 929176954872

500 500 500 500 500500

Curve Type LegendAve = Average ISTD

FORM VI 8260B 10162012Page 77 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07836d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07836dLab Smp Id IC-VMCAL1 Inj Date 17-SEP-2012 0449 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL1Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 2 Calibration Sample Level 1Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 8660 100000 11

3 Chloromethane 50 1004 1004 (0280) 21155 100000 12

4 Vinyl Chloride 62 1016 1016 (0283) 15876 100000 12

6 Bromomethane 94 1169 1169 (0326) 6723 100000 11

5 Chloroethane 64 1230 1230 (0343) 5433 100000 11

7 Trichlorofluoromethane 101 1291 1291 (0360) 13203 100000 12

14 Freon TF 101 1565 1565 (0436) 6213 100000 080(a)

15 11-Dichloroethene 96 1547 1547 (0431) 7415 100000 11

16 Acetone 58 1882 1882 (0524) 5188 500000 61

18 Carbon Disulfide 76 1559 1559 (0434) 32446 100000 10

27 Methyl Acetate 74 1955 1955 (0545) 2222 100000 11

22 Methylene Chloride 49 1851 1851 (0516) 20667 100000 12

28 MTBE 73 2016 2016 (0562) 32806 100000 10

25 trans-12-Dichloroethene 96 1937 1937 (0540) 9445 100000 100

30 11-Dichloroethane 63 2303 2303 (0642) 21457 100000 10

36 cis-12-Dichloroethene 96 2644 2644 (0737) 11702 100000 11

10162012Page 78 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07836d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0856) 6291 500000 40(a)

42 Chloroform 83 2839 2839 (0791) 17974 100000 098(a)

44 Cyclohexane 56 2778 2778 (0774) 14380 100000 075(a)

43 111-Trichloroethane 97 2973 2973 (0828) 14264 100000 092(a)

45 Carbon Tetrachloride 117 2924 2924 (0815) 11168 100000 089(a)

48 Benzene 78 3254 3254 (0468) 45050 100000 10

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 599539 500000 49

49 12-Dichloroethane 62 3412 3412 (0951) 15679 100000 10

52 Fluorobenzene 96 3589 3589 (1000) 2307227 500000

54 Trichloroethene 95 3735 3735 (1041) 11865 100000 11

56 Methyl cyclohexane 83 3723 3723 (1037) 10486 100000 068(a)

57 12-Dichloropropane 63 4192 4192 (1168) 12728 100000 10

68 Bromodichloromethane 83 4266 4266 (1189) 14807 100000 10

67 cis-13-Dichloropropene 75 4906 4906 (0706) 18914 100000 095(a)

70 4-Methyl-2-Pentanone 43 5625 5625 (0810) 67258 500000 50

$ 65 Toluene-d8 (SUR) 98 5101 5101 (0734) 2133452 500000 49

66 Toluene 91 5156 5156 (0742) 51238 100000 10

64 trans-13-Dichloropropene 75 5650 5650 (0813) 17115 100000 095(a)

69 112-Trichloroethane 83 5826 5826 (0839) 8636 100000 10

71 Tetrachloroethene 166 5582 5582 (0803) 10238 100000 088(a)

73 2-Hexanone 43 6674 6674 (0960) 49729 500000 50

74 Dibromochloromethane 129 6015 6015 (0866) 11301 100000 098(a)

77 12-Dibromoethane 107 6265 6265 (0902) 9735 100000 097(a)

78 Chlorobenzene-d5 117 6948 6948 (1000) 1875221 500000

79 Chlorobenzene 112 6972 6972 (1004) 33596 100000 10

81 Ethylbenzene 106 7064 7064 (1017) 17061 100000 096(a)

82 m+p-Xylene 106 7271 7271 (1046) 44761 200000 20

84 o-Xylene 106 7856 7856 (1131) 21499 100000 097(a)

85 Styrene 104 7942 7942 (1143) 36217 100000 096(a)

86 Bromoform 173 7911 7911 (1139) 7698 100000 096(a)

88 Isopropylbenzene 105 8344 8344 (1201) 49933 100000 094(a)

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 823604 500000 48

92 1122-Tetrachloroethane 83 9112 9112 (0871) 13823 100000 10

105 13-Dichlorobenzene 146 10332 10332 (0987) 26644 100000 099(a)

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1055978 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 28798 100000 10

111 12-Dichlorobenzene 146 11148 11148 (1065) 25972 100000 10(H)

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 2725 100000 11

114 124-Trichlorobenzene 180 12971 12971 (1239) 13808 100000 11

M 120 12-Dichloroethene (Total) 100 21147 200000 21

M 121 Xylene (Total) 100 66260 300000 30

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

H - Operator selected an alternate compound hit

10162012Page 79 of 323

Data File e07836d

Date 17-SEP-2012 0449

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL1 Operator GCMS VOAMS5

10162012Page 80 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07838d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07838dLab Smp Id IC-VMCAL2 Inj Date 17-SEP-2012 0536 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL2Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 4 Calibration Sample Level 2Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 39416 500000 48

3 Chloromethane 50 1016 1016 (0283) 83523 500000 48

4 Vinyl Chloride 62 1022 1022 (0285) 66919 500000 49

6 Bromomethane 94 1169 1169 (0326) 33032 500000 55

5 Chloroethane 64 1230 1230 (0343) 29332 500000 58

7 Trichlorofluoromethane 101 1291 1291 (0360) 49780 500000 45

14 Freon TF 101 1559 1559 (0434) 37580 500000 48

15 11-Dichloroethene 96 1541 1541 (0429) 31234 500000 45

16 Acetone 58 1894 1894 (0528) 13342 150000 16

18 Carbon Disulfide 76 1553 1553 (0433) 149121 500000 47

27 Methyl Acetate 74 1961 1961 (0546) 10660 500000 54

22 Methylene Chloride 49 1851 1851 (0516) 86862 500000 53

28 MTBE 73 2016 2016 (0562) 167790 500000 53

25 trans-12-Dichloroethene 96 1937 1937 (0540) 45844 500000 48

30 11-Dichloroethane 63 2296 2296 (0640) 104265 500000 49

36 cis-12-Dichloroethene 96 2644 2644 (0737) 55218 500000 51

10162012Page 81 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07838d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0857) 19260 150000 12

42 Chloroform 83 2839 2839 (0791) 94697 500000 52

44 Cyclohexane 56 2772 2772 (0772) 96765 500000 51

43 111-Trichloroethane 97 2973 2973 (0828) 71766 500000 46

45 Carbon Tetrachloride 117 2924 2924 (0815) 54679 500000 44

48 Benzene 78 3254 3254 (0468) 227079 500000 53

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 630441 500000 52

49 12-Dichloroethane 62 3412 3412 (0951) 78926 500000 52

52 Fluorobenzene 96 3589 3589 (1000) 2304638 500000

54 Trichloroethene 95 3735 3735 (1041) 50527 500000 46

56 Methyl cyclohexane 83 3717 3717 (1036) 79279 500000 52

57 12-Dichloropropane 63 4192 4192 (1168) 64209 500000 50

68 Bromodichloromethane 83 4272 4272 (1190) 72835 500000 49

67 cis-13-Dichloropropene 75 4906 4906 (0706) 95905 500000 50

70 4-Methyl-2-Pentanone 43 5625 5625 (0810) 195851 150000 15

$ 65 Toluene-d8 (SUR) 98 5101 5101 (0734) 2179204 500000 52

66 Toluene 91 5156 5156 (0742) 243768 500000 51

64 trans-13-Dichloropropene 75 5643 5643 (0812) 85943 500000 49

69 112-Trichloroethane 83 5820 5820 (0838) 42154 500000 51

71 Tetrachloroethene 166 5576 5576 (0803) 51530 500000 46

73 2-Hexanone 43 6680 6680 (0961) 148758 150000 15

74 Dibromochloromethane 129 6015 6015 (0866) 54107 500000 48

77 12-Dibromoethane 107 6259 6259 (0901) 49066 500000 51

78 Chlorobenzene-d5 117 6948 6948 (1000) 1811885 500000

79 Chlorobenzene 112 6972 6972 (1004) 162793 500000 50

81 Ethylbenzene 106 7058 7058 (1016) 81955 500000 48

82 m+p-Xylene 106 7271 7271 (1046) 208423 100000 97

84 o-Xylene 106 7856 7856 (1131) 102832 500000 48

85 Styrene 104 7942 7942 (1143) 179367 500000 50

86 Bromoform 173 7911 7911 (1139) 36074 500000 46

88 Isopropylbenzene 105 8344 8344 (1201) 244766 500000 48

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 813301 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 63947 500000 50

105 13-Dichlorobenzene 146 10325 10325 (0987) 126663 500000 50

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 998386 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 130929 500000 49

111 12-Dichlorobenzene 146 11148 11148 (1065) 121236 500000 50

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 11615 500000 51

114 124-Trichlorobenzene 180 12965 12965 (1239) 61295 500000 50

M 120 12-Dichloroethene (Total) 100 101062 100000 99

M 121 Xylene (Total) 100 311255 150000 14

10162012Page 82 of 323

Data File e07838d

Date 17-SEP-2012 0536

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL2 Operator GCMS VOAMS5

10162012Page 83 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07839d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07839dLab Smp Id ICIS-VMCAL3 Inj Date 17-SEP-2012 0600 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info ICIS-VMCAL3Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 5 Calibration Sample Level 3Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 167418 200000 20

3 Chloromethane 50 1016 1016 (0283) 353287 200000 20

4 Vinyl Chloride 62 1016 1016 (0283) 281874 200000 20

6 Bromomethane 94 1175 1175 (0327) 118799 200000 19

5 Chloroethane 64 1230 1230 (0343) 107678 200000 21

7 Trichlorofluoromethane 101 1291 1291 (0360) 228376 200000 20

14 Freon TF 101 1559 1559 (0434) 157867 200000 20

15 11-Dichloroethene 96 1540 1540 (0429) 147259 200000 21

16 Acetone 58 1888 1888 (0526) 17849 200000 20

18 Carbon Disulfide 76 1559 1559 (0434) 648801 200000 20

27 Methyl Acetate 74 1955 1955 (0545) 39926 200000 20

22 Methylene Chloride 49 1851 1851 (0516) 340378 200000 20

28 MTBE 73 2016 2016 (0562) 658123 200000 20

25 trans-12-Dichloroethene 96 1943 1943 (0541) 203500 200000 21

30 11-Dichloroethane 63 2303 2303 (0642) 465144 200000 21

36 cis-12-Dichloroethene 96 2644 2644 (0737) 233129 200000 21

10162012Page 84 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07839d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0856) 36552 200000 22

42 Chloroform 83 2839 2839 (0791) 383084 200000 20

44 Cyclohexane 56 2778 2778 (0774) 383104 200000 19

43 111-Trichloroethane 97 2973 2973 (0828) 333961 200000 21

45 Carbon Tetrachloride 117 2924 2924 (0815) 265527 200000 21

48 Benzene 78 3254 3254 (0468) 968083 200000 21

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 611357 500000 49

49 12-Dichloroethane 62 3412 3412 (0951) 312991 200000 20

52 Fluorobenzene 96 3589 3589 (1000) 2376396 500000

54 Trichloroethene 95 3735 3735 (1041) 229465 200000 20

56 Methyl cyclohexane 83 3723 3723 (1037) 312424 200000 20

57 12-Dichloropropane 63 4192 4192 (1168) 266559 200000 20

68 Bromodichloromethane 83 4266 4266 (1189) 302742 200000 20

67 cis-13-Dichloropropene 75 4906 4906 (0705) 412847 200000 20

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 271059 200000 20

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2252606 500000 50

66 Toluene 91 5156 5156 (0741) 1095520 200000 22

64 trans-13-Dichloropropene 75 5643 5643 (0812) 369516 200000 20

69 112-Trichloroethane 83 5820 5820 (0837) 175853 200000 20

71 Tetrachloroethene 166 5576 5576 (0802) 258990 200000 22

73 2-Hexanone 43 6680 6680 (0961) 205286 200000 20

74 Dibromochloromethane 129 6015 6015 (0865) 237421 200000 20

77 12-Dibromoethane 107 6259 6259 (0900) 210900 200000 20

78 Chlorobenzene-d5 117 6954 6954 (1000) 1921967 500000

79 Chlorobenzene 112 6972 6972 (1003) 714336 200000 21

81 Ethylbenzene 106 7064 7064 (1016) 380762 200000 21

82 m+p-Xylene 106 7277 7277 (1046) 968280 400000 42

84 o-Xylene 106 7856 7856 (1130) 472158 200000 21

85 Styrene 104 7942 7942 (1142) 809158 200000 21

86 Bromoform 173 7911 7911 (1138) 165267 200000 20

88 Isopropylbenzene 105 8344 8344 (1200) 1199765 200000 22

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 847619 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 277413 200000 20

105 13-Dichlorobenzene 146 10325 10325 (0987) 557342 200000 21

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1048295 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 574816 200000 21

111 12-Dichlorobenzene 146 11148 11148 (1065) 528396 200000 21

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 45388 200000 19

114 124-Trichlorobenzene 180 12965 12965 (1239) 264648 200000 21

M 120 12-Dichloroethene (Total) 100 436629 400000 42

M 121 Xylene (Total) 100 1440438 600000 63

10162012Page 85 of 323

Data File e07839d

Date 17-SEP-2012 0600

Client ID Instrument VOAMS5i

Sample Info ICIS-VMCAL3 Operator GCMS VOAMS5

10162012Page 86 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07840d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07840dLab Smp Id IC-VMCAL4 Inj Date 17-SEP-2012 0623 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL4Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 6 Calibration Sample Level 4Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 450014 500000 53

3 Chloromethane 50 1010 1010 (0281) 935453 500000 52

4 Vinyl Chloride 62 1016 1016 (0283) 757876 500000 53

6 Bromomethane 94 1175 1175 (0327) 307121 500000 49

5 Chloroethane 64 1230 1230 (0342) 284219 500000 54

7 Trichlorofluoromethane 101 1290 1290 (0359) 566305 500000 49

14 Freon TF 101 1565 1565 (0435) 443949 500000 55

15 11-Dichloroethene 96 1540 1540 (0428) 355088 500000 49

16 Acetone 58 1888 1888 (0525) 43750 500000 50

18 Carbon Disulfide 76 1559 1559 (0434) 1763903 500000 53

27 Methyl Acetate 74 1961 1961 (0546) 101112 500000 49

22 Methylene Chloride 49 1851 1851 (0515) 840419 500000 49

28 MTBE 73 2016 2016 (0561) 1636664 500000 50

25 trans-12-Dichloroethene 96 1943 1943 (0540) 521911 500000 53

30 11-Dichloroethane 63 2302 2302 (0640) 1121930 500000 51

36 cis-12-Dichloroethene 96 2644 2644 (0735) 567238 500000 50

10162012Page 87 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07840d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0854) 89217 500000 54

42 Chloroform 83 2839 2839 (0790) 974788 500000 51

44 Cyclohexane 56 2778 2778 (0773) 1067735 500000 54

43 111-Trichloroethane 97 2973 2973 (0827) 821993 500000 51

45 Carbon Tetrachloride 117 2924 2924 (0813) 675330 500000 52

48 Benzene 78 3254 3254 (0468) 2380099 500000 51

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0934) 613057 500000 48

49 12-Dichloroethane 62 3412 3412 (0949) 785178 500000 50

52 Fluorobenzene 96 3595 3595 (1000) 2400971 500000

54 Trichloroethene 95 3735 3735 (1039) 562086 500000 49

56 Methyl cyclohexane 83 3723 3723 (1036) 894738 500000 56

57 12-Dichloropropane 63 4192 4192 (1166) 655380 500000 50

68 Bromodichloromethane 83 4272 4272 (1188) 754124 500000 49

67 cis-13-Dichloropropene 75 4906 4906 (0705) 1024782 500000 49

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 697282 500000 49

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2273339 500000 50

66 Toluene 91 5162 5162 (0742) 2719268 500000 52

64 trans-13-Dichloropropene 75 5649 5649 (0812) 938808 500000 50

69 112-Trichloroethane 83 5820 5820 (0837) 432262 500000 49

71 Tetrachloroethene 166 5576 5576 (0802) 639002 500000 52

73 2-Hexanone 43 6680 6680 (0961) 526223 500000 50

74 Dibromochloromethane 129 6015 6015 (0865) 599464 500000 49

77 12-Dibromoethane 107 6259 6259 (0900) 524614 500000 50

78 Chlorobenzene-d5 117 6954 6954 (1000) 1964266 500000

79 Chlorobenzene 112 6972 6972 (1003) 1781568 500000 51

81 Ethylbenzene 106 7064 7064 (1016) 955894 500000 51

82 m+p-Xylene 106 7277 7277 (1046) 2423002 100000 100

84 o-Xylene 106 7862 7862 (1131) 1181273 500000 51

85 Styrene 104 7942 7942 (1142) 2064560 500000 52

86 Bromoform 173 7911 7911 (1138) 430943 500000 51

88 Isopropylbenzene 105 8350 8350 (1201) 3014281 500000 54

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 870646 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 702309 500000 50

105 13-Dichlorobenzene 146 10331 10331 (0987) 1421450 500000 51

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1082388 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 1464915 500000 51

111 12-Dichlorobenzene 146 11154 11154 (1066) 1324016 500000 50

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 120062 500000 49

114 124-Trichlorobenzene 180 12971 12971 (1239) 678119 500000 51

M 120 12-Dichloroethene (Total) 100 1089149 100000 100

M 121 Xylene (Total) 100 3604275 150000 160

10162012Page 88 of 323

Data File e07840d

Date 17-SEP-2012 0623

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL4 Operator GCMS VOAMS5

10162012Page 89 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07841d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07841dLab Smp Id IC-VMCAL5 Inj Date 17-SEP-2012 0646 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL5Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 7 Calibration Sample Level 5Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 1798263 200000 200

3 Chloromethane 50 1010 1010 (0281) 3551906 200000 190

4 Vinyl Chloride 62 1016 1016 (0283) 2954383 200000 200

6 Bromomethane 94 1175 1175 (0327) 1285567 200000 190

5 Chloroethane 64 1230 1230 (0342) 1005976 200000 180

7 Trichlorofluoromethane 101 1291 1291 (0359) 2495326 200000 200

14 Freon TF 101 1565 1565 (0435) 1913025 200000 220

15 11-Dichloroethene 96 1541 1541 (0429) 1549102 200000 200

16 Acetone 58 1894 1894 (0527) 164598 200000 180

18 Carbon Disulfide 76 1559 1559 (0434) 7384049 200000 210

27 Methyl Acetate 74 1961 1961 (0546) 407713 200000 190

22 Methylene Chloride 49 1851 1851 (0515) 3225631 200000 180

28 MTBE 73 2016 2016 (0561) 7002522 200000 200

25 trans-12-Dichloroethene 96 1943 1943 (0540) 2044335 200000 200

30 11-Dichloroethane 63 2303 2303 (0640) 4556341 200000 200

36 cis-12-Dichloroethene 96 2650 2650 (0737) 2267968 200000 190

10162012Page 90 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07841d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0854) 377317 200000 220

42 Chloroform 83 2839 2839 (0790) 4002506 200000 200

44 Cyclohexane 56 2784 2784 (0774) 4704103 200000 220

43 111-Trichloroethane 97 2979 2979 (0829) 3633125 200000 210

45 Carbon Tetrachloride 117 2930 2930 (0815) 2970592 200000 220

48 Benzene 78 3260 3260 (0468) 9863557 200000 210

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 676105 500000 50

49 12-Dichloroethane 62 3418 3418 (0951) 3236838 200000 190

52 Fluorobenzene 96 3595 3595 (1000) 2534623 500000

54 Trichloroethene 95 3741 3741 (1041) 2397838 200000 200

56 Methyl cyclohexane 83 3729 3729 (1037) 3740947 200000 220

57 12-Dichloropropane 63 4199 4199 (1168) 2762116 200000 200

68 Bromodichloromethane 83 4272 4272 (1188) 3283607 200000 200

67 cis-13-Dichloropropene 75 4912 4912 (0706) 4330221 200000 200

70 4-Methyl-2-Pentanone 43 5631 5631 (0809) 2892746 200000 200

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2337515 500000 50

66 Toluene 91 5162 5162 (0742) 10779721 200000 200

64 trans-13-Dichloropropene 75 5656 5656 (0813) 3942425 200000 200

69 112-Trichloroethane 83 5826 5826 (0837) 1754301 200000 190

71 Tetrachloroethene 166 5582 5582 (0802) 2589541 200000 210

73 2-Hexanone 43 6686 6686 (0961) 2211715 200000 210

74 Dibromochloromethane 129 6021 6021 (0865) 2498269 200000 200

77 12-Dibromoethane 107 6265 6265 (0900) 2110766 200000 200

78 Chlorobenzene-d5 117 6960 6960 (1000) 2007362 500000

79 Chlorobenzene 112 6978 6978 (1003) 7007520 200000 200

81 Ethylbenzene 106 7076 7076 (1017) 3881643 200000 200

82 m+p-Xylene 106 7289 7289 (1047) 9786882 400000 410

84 o-Xylene 106 7869 7869 (1131) 4809215 200000 200

85 Styrene 104 7954 7954 (1143) 8412645 200000 210

86 Bromoform 173 7923 7923 (1138) 1812795 200000 210

88 Isopropylbenzene 105 8356 8356 (1201) 12317103 200000 220(A)

$ 89 Bromofluorobenzene (SUR) 174 8716 8716 (0832) 929176 500000 51

92 1122-Tetrachloroethane 83 9124 9124 (0871) 2898768 200000 200

105 13-Dichlorobenzene 146 10344 10344 (0987) 5787314 200000 200

108 14-Dichlorobenzene-d4 152 10478 10478 (1000) 1134091 500000

109 14-Dichlorobenzene 146 10502 10502 (1002) 5901891 200000 200

111 12-Dichlorobenzene 146 11167 11167 (1066) 5328621 200000 190

112 12-Dibromo-3-chloropropane 75 12240 12240 (1168) 472744 200000 180

114 124-Trichlorobenzene 180 12971 12971 (1238) 2596959 200000 190

M 120 12-Dichloroethene (Total) 100 4312303 400000 380

M 121 Xylene (Total) 100 14596097 600000 620

QC Flag Legend

A - Target compound detected but quantitated amountexceeded maximum amount

10162012Page 91 of 323

Data File e07841d

Date 17-SEP-2012 0646

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL5 Operator GCMS VOAMS5

10162012Page 92 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07842d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07842dLab Smp Id IC-VMCAL6 Inj Date 17-SEP-2012 0710 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL6Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 8 Calibration Sample Level 6Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 4551928 500000 450

3 Chloromethane 50 1010 1010 (0280) 8902969 500000 410

4 Vinyl Chloride 62 1016 1016 (0282) 7332518 500000 420

6 Bromomethane 94 1175 1175 (0326) 3429373 500000 450

5 Chloroethane 64 1230 1230 (0341) 2426216 500000 380

7 Trichlorofluoromethane 101 1297 1297 (0360) 6618134 500000 470

14 Freon TF 101 1571 1571 (0436) 5130629 500000 520(A)

15 11-Dichloroethene 96 1547 1547 (0429) 4214942 500000 490

16 Acetone 58 1894 1894 (0526) 441742 500000 420

18 Carbon Disulfide 76 1559 1559 (0433) 18433408 500000 460

27 Methyl Acetate 74 1961 1961 (0545) 1074355 500000 440

22 Methylene Chloride 49 1851 1851 (0514) 8533685 500000 410

28 MTBE 73 2022 2022 (0562) 17351574 500000 440

25 trans-12-Dichloroethene 96 1943 1943 (0540) 5633771 500000 470

30 11-Dichloroethane 63 2302 2302 (0639) 12326764 500000 460

36 cis-12-Dichloroethene 96 2650 2650 (0736) 6324299 500000 460

10162012Page 93 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07842d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3083 3083 (0856) 1055008 500000 530(A)

42 Chloroform 83 2845 2845 (0790) 11152231 500000 480

44 Cyclohexane 56 2790 2790 (0775) 12852489 500000 540(A)

43 111-Trichloroethane 97 2985 2985 (0829) 10199723 500000 520(A)

45 Carbon Tetrachloride 117 2936 2936 (0815) 8405131 500000 540(A)

48 Benzene 78 3260 3260 (0468) 21876514 500000 410

$ 47 12-Dichloroethane-d4 (SUR) 65 3369 3369 (0936) 782507 500000 51

49 12-Dichloroethane 62 3424 3424 (0951) 9046377 500000 480

52 Fluorobenzene 96 3601 3601 (1000) 2895790 500000

54 Trichloroethene 95 3753 3753 (1042) 7026524 500000 510(A)

56 Methyl cyclohexane 83 3741 3741 (1039) 10227785 500000 530(A)

57 12-Dichloropropane 63 4205 4205 (1168) 7913672 500000 500

68 Bromodichloromethane 83 4284 4284 (1190) 9374106 500000 510(A)

67 cis-13-Dichloropropene 75 4924 4924 (0706) 12299317 500000 520(A)

70 4-Methyl-2-Pentanone 43 5649 5649 (0810) 8212153 500000 510(A)

$ 65 Toluene-d8 (SUR) 98 5113 5113 (0733) 2600040 500000 50

66 Toluene 91 5168 5168 (0741) 23868197 500000 400

64 trans-13-Dichloropropene 75 5668 5668 (0813) 11373599 500000 530(A)

69 112-Trichloroethane 83 5838 5838 (0837) 5071317 500000 500(A)

71 Tetrachloroethene 166 5594 5594 (0802) 7239654 500000 520(A)

73 2-Hexanone 43 6698 6698 (0961) 5590902 500000 470

74 Dibromochloromethane 129 6033 6033 (0865) 7227226 500000 530(A)

77 12-Dibromoethane 107 6277 6277 (0900) 5952425 500000 500(A)

78 Chlorobenzene-d5 117 6972 6972 (1000) 2224153 500000

79 Chlorobenzene 112 6997 6997 (1003) 18374405 500000 460

81 Ethylbenzene 106 7094 7094 (1017) 10693410 500000 500(A)

82 m+p-Xylene 106 7308 7308 (1048) 23238078 100000 880

84 o-Xylene 106 7887 7887 (1131) 12821590 500000 490

85 Styrene 104 7966 7966 (1143) 19831782 500000 440

86 Bromoform 173 7942 7942 (1139) 4974461 500000 520(A)

88 Isopropylbenzene 105 8368 8368 (1200) 26165908 500000 420(A)

$ 89 Bromofluorobenzene (SUR) 174 8728 8728 (0832) 954872 500000 51

92 1122-Tetrachloroethane 83 9143 9143 (0871) 7365342 500000 490

105 13-Dichlorobenzene 146 10362 10362 (0987) 14243841 500000 480

108 14-Dichlorobenzene-d4 152 10496 10496 (1000) 1163568 500000

109 14-Dichlorobenzene 146 10526 10526 (1003) 14602396 500000 470

111 12-Dichlorobenzene 146 11185 11185 (1066) 13405399 500000 480

112 12-Dibromo-3-chloropropane 75 12246 12246 (1167) 1274610 500000 480

114 124-Trichlorobenzene 180 12977 12977 (1236) 6669727 500000 470

M 120 12-Dichloroethene (Total) 100 11958070 100000 940

M 121 Xylene (Total) 100 36059668 150000 1400

QC Flag Legend

A - Target compound detected but quantitated amountexceeded maximum amount

10162012Page 94 of 323

Data File e07842d

Date 17-SEP-2012 0710

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL6 Operator GCMS VOAMS5

10162012Page 95 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10112012 2050

09172012 0449

09172012 0710

CCVIS 460-1316562

Rtx-VMS

TestAmerica Edison

Lab File ID e08976d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Dichlorodifluoromethane 0194701761 01000 221 200 105 250Ave

Chloromethane 0322303733 01000 173 200 -137 250Ave

Vinyl chloride 0274402985 01000 184 200 -81 250Ave

Bromomethane 0159401312 01000 243 200 215 250Ave

Chloroethane 0127501099 01000 232 200 160 250Ave

Trichlorofluoromethane 0296002422 01000 244 200 222 250Ave

11-Dichloroethene 0161001496 01000 215 200 76 250Ave

Carbon disulfide 0655806887 01000 190 200 -48 250Ave

112-Trichloro-122-trifluoroethane

0198901691 01000 235 200 176 250Ave

Methylene Chloride 0341503576 01000 191 200 -45 250Ave

Acetone 0021400184 01000 233 200 164 250Ave

trans-12-Dichloroethene 0208902052 01000 204 200 18 250Ave

Methyl acetate 0037700426 01000 177 200 -115 250Ave

Methyl tert-butyl ether 0665806838 01000 195 200 -26 250Ave

11-Dichloroethane 0443404582 01000 194 200 -32 250Ave

cis-12-Dichloroethene 0227602361 01000 193 200 -36 250Ave

Cyclohexane 0338904145 01000 163 200 -183 250Ave

Chloroform 0397703982 01000 200 200 -01 250Ave

Carbon tetrachloride 0281602705 01000 208 200 41 250Ave

111-Trichloroethane 0352303375 01000 209 200 44 250Ave

2-Butanone (MEK) 0035400341 01000 208 200 40 250Ave

Benzene 10301190 01000 173 200 -134 250Ave

12-Dichloroethane 0331603284 01000 202 200 10 250Ave

Methylcyclohexane 0280603325 01000 169 200 -156 250Ave

Trichloroethene 0228602385 01000 192 200 -41 250Ave

12-Dichloropropane 0242002756 01000 176 200 -122 250Ave

Dichlorobromomethane 0303603195 01000 190 200 -50 250Ave

cis-13-Dichloropropene 0438605308 01000 165 200 -174 250Ave

Toluene 12151323 01000 184 200 -81 250Ave

Tetrachloroethene 0302803113 01000 195 200 -27 250Ave

4-Methyl-2-pentanone (MIBK) 0273203593 01000 152 200 -240 250Ave

trans-13-Dichloropropene 0396604819 01000 165 200 -177 250Ave

112-Trichloroethane 0185102264 01000 164 200 -182 250Ave

Chlorodibromomethane 0265003083 01000 172 200 -141 250Ave

12-Dibromoethane 0231002670 01000 173 200 -135 250Ave

2-Hexanone 0209702668 01000 157 200 -214 250Ave

Chlorobenzene 0830208882 01000 187 200 -65 250Ave

Ethylbenzene 0437104756 01000 184 200 -81 250Ave

m-Xylene amp p-Xylene 0555805917 01000 376 400 -61 250Ave

o-Xylene 0545405886 01000 185 200 -73 250Ave

FORM VII 8260B

10162012Page 96 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10112012 2050

09172012 0449

09172012 0710

CCVIS 460-1316562

Rtx-VMS

TestAmerica Edison

Lab File ID e08976d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Bromoform 0188102147 01000 175 200 -124 250Ave

Styrene 092181000 01000 184 200 -78 250Ave

Isopropylbenzene 13421415 01000 190 200 -52 250Ave

1122-Tetrachloroethane 0512306462 01000 159 200 -207 250Ave

13-Dichlorobenzene 11861279 01000 186 200 -72 250Ave

14-Dichlorobenzene 12311326 01000 186 200 -72 250Ave

12-Dichlorobenzene 11211209 01000 185 200 -73 250Ave

12-Dibromo-3-Chloropropane 0086101130 01000 152 200 -238 250Ave

124-Trichlorobenzene 0630306118 01000 206 200 30 250Ave

12-Dichloroethane-d4 (Surr) 0310902638 01000 589 500 178 250Ave

Toluene-d8 (Surr) 11551167 01000 495 500 -11 250Ave

4-Bromofluorobenzene 0811108079 01000 502 500 04 250Ave

FORM VII 8260B

10162012Page 97 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08976d Report Date 11-Oct-2012 2130

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08976dLab Smp Id CCVIS Inj Date 11-OCT-2012 2050 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info CCVISMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 1 Continuing Calibration SampleDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0900 0900 (0250) 102235 200000 22

3 Chloromethane 50 1016 1016 (0282) 169224 200000 17

4 Vinyl Chloride 62 1028 1028 (0286) 144069 200000 18

6 Bromomethane 94 1181 1181 (0328) 83687 200000 24

5 Chloroethane 64 1242 1242 (0345) 66969 200000 23

7 Trichlorofluoromethane 101 1303 1303 (0362) 155393 200000 24

14 Freon TF 101 1577 1577 (0438) 104446 200000 24

15 11-Dichloroethene 96 1553 1553 (0431) 84531 200000 22

16 Acetone 58 1894 1894 (0526) 11228 200000 23

18 Carbon Disulfide 76 1571 1571 (0436) 344348 200000 19

27 Methyl Acetate 74 1967 1967 (0546) 19813 200000 18

22 Methylene Chloride 49 1864 1864 (0518) 179288 200000 19

28 MTBE 73 2022 2022 (0562) 349596 200000 19

25 trans-12-Dichloroethene 96 1949 1949 (0541) 109681 200000 20

30 11-Dichloroethane 63 2309 2309 (0641) 232818 200000 19

36 cis-12-Dichloroethene 96 2656 2656 (0738) 119502 200000 19

10162012Page 98 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08976d Report Date 11-Oct-2012 2130

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0854) 18598 200000 21

42 Chloroform 83 2845 2845 (0790) 208815 200000 20

44 Cyclohexane 56 2784 2784 (0773) 177923 200000 16

43 111-Trichloroethane 97 2985 2985 (0829) 185002 200000 21

45 Carbon Tetrachloride 117 2937 2937 (0815) 147853 200000 21

48 Benzene 78 3260 3260 (0469) 476925 200000 17

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0934) 408134 500000 59

49 12-Dichloroethane 62 3418 3418 (0949) 174132 200000 20

52 Fluorobenzene 96 3601 3601 (1000) 1312656 500000

54 Trichloroethene 95 3741 3741 (1039) 120041 200000 19

56 Methyl cyclohexane 83 3729 3729 (1036) 147336 200000 17

57 12-Dichloropropane 63 4199 4199 (1166) 127078 200000 18

68 Bromodichloromethane 83 4272 4272 (1186) 159386 200000 19

67 cis-13-Dichloropropene 75 4912 4912 (0706) 203059 200000 16

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 126467 200000 15

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1336847 500000 49

66 Toluene 91 5162 5162 (0742) 562689 200000 18

64 trans-13-Dichloropropene 75 5649 5649 (0812) 183587 200000 16

69 112-Trichloroethane 83 5820 5820 (0837) 85707 200000 16

71 Tetrachloroethene 166 5582 5582 (0803) 140177 200000 19

73 2-Hexanone 43 6680 6680 (0961) 97080 200000 16

74 Dibromochloromethane 129 6021 6021 (0866) 122657 200000 17

77 12-Dibromoethane 107 6265 6265 (0901) 106920 200000 17

78 Chlorobenzene-d5 117 6954 6954 (1000) 1157341 500000

79 Chlorobenzene 112 6972 6972 (1003) 384334 200000 19

81 Ethylbenzene 106 7064 7064 (1016) 202362 200000 18

82 m+p-Xylene 106 7277 7277 (1046) 514606 400000 38

84 o-Xylene 106 7862 7862 (1131) 252476 200000 18

85 Styrene 104 7942 7942 (1142) 426740 200000 18

86 Bromoform 173 7911 7911 (1138) 87078 200000 18

88 Isopropylbenzene 105 8350 8350 (1201) 621124 200000 19

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 541700 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 136860 200000 16

105 13-Dichlorobenzene 146 10331 10331 (0987) 316835 200000 18

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 667834 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 328709 200000 18

111 12-Dichlorobenzene 146 11148 11148 (1065) 299393 200000 18

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 23001 200000 15

114 124-Trichlorobenzene 180 12977 12977 (1240) 168371 200000 21

M 120 12-Dichloroethene (Total) 100 229183 400000 40

M 121 Xylene (Total) 100 767082 600000 56

10162012Page 99 of 323

Data File e08976d

Date 11-OCT-2012 2050

Client ID Instrument VOAMS5i

Sample Info CCVIS Operator GCMS VOAMS5

10162012Page 100 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10122012 0114

09172012 0449

09172012 0710

CCV 460-13165610

Rtx-VMS

TestAmerica Edison

Lab File ID e08987d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Dichlorodifluoromethane 0166601761 01000 189 200 -54 250Ave

Chloromethane 0311403733 01000 167 200 -166 250Ave

Vinyl chloride 0256002985 01000 172 200 -142 250Ave

Bromomethane 0162301312 01000 247 200 237 250Ave

Chloroethane 0127201099 01000 231 200 157 250Ave

Trichlorofluoromethane 0257102422 01000 212 200 62 250Ave

11-Dichloroethene 0184901496 01000 247 200 236 250Ave

112-Trichloro-122-trifluoroethane

0225501691 01000 267 200 334 250Ave

Carbon disulfide 0788506887 01000 229 200 145 250Ave

Methylene Chloride 0351303576 01000 196 200 -18 250Ave

Acetone 0022000184 01000 239 200 197 250Ave

trans-12-Dichloroethene 0232002052 01000 226 200 130 250Ave

Methyl acetate 0048700426 01000 228 200 141 250Ave

Methyl tert-butyl ether 0769506838 01000 225 200 125 250Ave

11-Dichloroethane 0469804582 01000 205 200 25 250Ave

cis-12-Dichloroethene 0240902361 01000 204 200 20 250Ave

Cyclohexane 0384004145 01000 185 200 -74 250Ave

Chloroform 0438203982 01000 220 200 100 250Ave

Carbon tetrachloride 0291802705 01000 216 200 79 250Ave

111-Trichloroethane 0362803375 01000 215 200 75 250Ave

2-Butanone (MEK) 0042500341 01000 250 200 248 250Ave

Benzene 11151190 01000 188 200 -62 250Ave

12-Dichloroethane 0359603284 01000 219 200 95 250Ave

Methylcyclohexane 0344803325 01000 207 200 37 250Ave

Trichloroethene 0248302385 01000 208 200 41 250Ave

12-Dichloropropane 0265202756 01000 192 200 -38 250Ave

Dichlorobromomethane 0339803195 01000 213 200 63 250Ave

cis-13-Dichloropropene 0490405308 01000 185 200 -76 250Ave

Toluene 12801323 01000 194 200 -32 250Ave

Tetrachloroethene 0323103113 01000 208 200 38 250Ave

4-Methyl-2-pentanone (MIBK) 0319703593 01000 178 200 -110 250Ave

trans-13-Dichloropropene 0454104819 01000 188 200 -58 250Ave

112-Trichloroethane 0212502264 01000 188 200 -61 250Ave

Chlorodibromomethane 0306403083 01000 199 200 -06 250Ave

12-Dibromoethane 0261302670 01000 196 200 -22 250Ave

2-Hexanone 0243802668 01000 183 200 -86 250Ave

Chlorobenzene 0879308882 01000 198 200 -10 250Ave

Ethylbenzene 0463104756 01000 195 200 -26 250Ave

m-Xylene amp p-Xylene 0587505917 01000 397 400 -07 250Ave

o-Xylene 0578505886 01000 197 200 -17 250Ave

FORM VII 8260B

10162012Page 101 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10122012 0114

09172012 0449

09172012 0710

CCV 460-13165610

Rtx-VMS

TestAmerica Edison

Lab File ID e08987d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Bromoform 0223102147 01000 208 200 39 250Ave

Styrene 099051000 01000 198 200 -09 250Ave

Isopropylbenzene 14391415 01000 203 200 17 250Ave

1122-Tetrachloroethane 0579606462 01000 179 200 -103 250Ave

13-Dichlorobenzene 12591279 01000 197 200 -15 250Ave

14-Dichlorobenzene 13061326 01000 197 200 -15 250Ave

12-Dichlorobenzene 12151209 01000 201 200 05 250Ave

12-Dibromo-3-Chloropropane 0102901130 01000 182 200 -90 250Ave

124-Trichlorobenzene 0743906118 01000 243 200 216 250Ave

12-Dichloroethane-d4 (Surr) 0320902638 01000 608 500 216 250Ave

Toluene-d8 (Surr) 11471167 01000 491 500 -18 250Ave

4-Bromofluorobenzene 0806308079 01000 499 500 -02 250Ave

FORM VII 8260B

10162012Page 102 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12abe08987d Report Date 12-Oct-2012 0132

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12abe08987dLab Smp Id CCV Inj Date 12-OCT-2012 0114 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info CCVMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12ab8260DE_09mMeth Date 12-Oct-2012 0132 ken Quant Type ISTDCal Date 12-OCT-2012 0114 Cal File e08987dAls bottle 12 Continuing Calibration SampleDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0894 (0249) 84911 200000 19

3 Chloromethane 50 1016 1016 (0283) 158694 200000 17

4 Vinyl Chloride 62 1022 1022 (0284) 130464 200000 17

6 Bromomethane 94 1181 1181 (0328) 82695 200000 25

5 Chloroethane 64 1236 1236 (0344) 64840 200000 23

7 Trichlorofluoromethane 101 1297 1297 (0361) 131020 200000 21

14 Freon TF 101 1565 1565 (0435) 114931 200000 27

15 11-Dichloroethene 96 1547 1547 (0430) 94244 200000 25

16 Acetone 58 1894 1894 (0527) 11208 200000 24

18 Carbon Disulfide 76 1565 1565 (0435) 401807 200000 23

27 Methyl Acetate 74 1961 1961 (0546) 24794 200000 23

22 Methylene Chloride 49 1857 1857 (0517) 179010 200000 20

28 MTBE 73 2022 2022 (0562) 392131 200000 22

25 trans-12-Dichloroethene 96 1943 1943 (0540) 118223 200000 23

30 11-Dichloroethane 63 2302 2302 (0640) 239419 200000 20

36 cis-12-Dichloroethene 96 2650 2650 (0737) 122782 200000 20

10162012Page 103 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12abe08987d Report Date 12-Oct-2012 0132

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0856) 21666 200000 25

42 Chloroform 83 2845 2845 (0791) 223324 200000 22

44 Cyclohexane 56 2784 2784 (0774) 195679 200000 18

43 111-Trichloroethane 97 2979 2979 (0829) 184861 200000 21

45 Carbon Tetrachloride 117 2930 2930 (0815) 148689 200000 22

48 Benzene 78 3260 3260 (0469) 501947 200000 19

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 408924 500000 61

49 12-Dichloroethane 62 3418 3418 (0951) 183231 200000 22

52 Fluorobenzene 96 3595 3595 (1000) 1274024 500000

54 Trichloroethene 95 3741 3741 (1041) 126518 200000 21

56 Methyl cyclohexane 83 3723 3723 (1036) 175700 200000 21

57 12-Dichloropropane 63 4192 4192 (1166) 135130 200000 19

68 Bromodichloromethane 83 4272 4272 (1188) 173147 200000 21

67 cis-13-Dichloropropene 75 4906 4906 (0705) 220680 200000 18

70 4-Methyl-2-Pentanone 43 5631 5631 (0810) 143892 200000 18

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1290179 500000 49

66 Toluene 91 5162 5162 (0742) 576151 200000 19

64 trans-13-Dichloropropene 75 5649 5649 (0812) 204342 200000 19

69 112-Trichloroethane 83 5820 5820 (0837) 95620 200000 19

71 Tetrachloroethene 166 5582 5582 (0803) 145404 200000 21

73 2-Hexanone 43 6680 6680 (0961) 109697 200000 18

74 Dibromochloromethane 129 6015 6015 (0865) 137888 200000 20

77 12-Dibromoethane 107 6265 6265 (0901) 117575 200000 20

78 Chlorobenzene-d5 117 6954 6954 (1000) 1125053 500000

79 Chlorobenzene 112 6972 6972 (1003) 395719 200000 20

81 Ethylbenzene 106 7064 7064 (1016) 208414 200000 19

82 m+p-Xylene 106 7277 7277 (1046) 528781 400000 40

84 o-Xylene 106 7856 7856 (1130) 260320 200000 20

85 Styrene 104 7942 7942 (1142) 445737 200000 20

86 Bromoform 173 7917 7917 (1139) 100375 200000 21

88 Isopropylbenzene 105 8344 8344 (1200) 647568 200000 20

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 536325 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 154190 200000 18

105 13-Dichlorobenzene 146 10331 10331 (0987) 335032 200000 20

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 665092 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 347387 200000 20

111 12-Dichlorobenzene 146 11148 11148 (1065) 323155 200000 20

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 27376 200000 18

114 124-Trichlorobenzene 180 12977 12977 (1240) 197894 200000 24

M 120 12-Dichloroethene (Total) 100 241005 400000 43

M 121 Xylene (Total) 100 789101 600000 59

10162012Page 104 of 323

Data File e08987d

Date 12-OCT-2012 0114

Client ID Instrument VOAMS5i

Sample Info CCV Operator GCMS VOAMS5

10162012Page 105 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07834d Report Date 17-Sep-2012 0605

TestAmerica

Data file chemVOAMS5i8260DE09-17-1217sep12be07834dLab Smp Id BFB Inj Date 17-SEP-2012 0324 Operator VOAMS 1 Inst ID VOAMS5iSmp Info BFBMisc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12bBFBDELmMeth Date 27-Feb-2012 1508 sylvanus Quant Type ISTDCal Date Cal File Als bottle 2 QC Sample BFBDil Factor 100000 Integrator HP RTE Compound Sublist allsubTarget Version 350 Sample Matrix WATERProcessing Host hpd2

Concentration Formula Amt DF Uf Vf VI CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorUf 100000 ng unit correction factorVf 100000 Volumetric correction factorVI 100000 Injection Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT (REL RT) MASS RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ==== ======== ======= ======= ============ =====

1 BFB CAS 460-00-4

2352 2600 (0000) 95 195072 000- 10000 10000

2352 2600 (0000) 50 42624 1500- 4000 2185

2352 2600 (0000) 75 102376 3000- 6000 5248

2352 2600 (0000) 96 12530 500- 900 642

2352 2600 (0000) 173 0 000- 200 000

2352 2600 (0000) 174 155200 5000- 10000 7956

2352 2600 (0000) 175 12902 500- 900 831

2352 2600 (0000) 176 148480 9500- 10100 9567

2352 2600 (0000) 177 9343 500- 900 629

-------------------------------------------------------------------------------

10162012Page 106 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

10162012Page 107 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

1 BFB

RELATIVE me ION ABUNDANCE CRITERIA ABUNDANCE

+-----+------------------------------------------+---------------------+| | | || 95 | Base Peak 100 relative abundance | 10000 || 50 | 1500 - 4000 of mass 95 | 2185 || 75 | 3000 - 6000 of mass 95 | 5248 || 96 | 500 - 900 of mass 95 | 642 || 173 | Less than 200 of mass 174 | 000 ( 000) || 174 | 5000 - 10000 of mass 95 | 7956 || 175 | 500 - 900 of mass 174 | 661 ( 831) || 176 | 9500 - 10100 of mass 174 | 7612 ( 9567) || 177 | 500 - 900 of mass 176 | 479 ( 629) |+-----+------------------------------------------+---------------------+

10162012Page 108 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

Data File chemVOAMS5i8260DE09-17-1217sep12be07834dSpectrum Avg Scans 50-52 ( 235) Background Scan 46

Location of Maximum 9500Number of points 151

mz Y mz Y mz Y mz Y+------------------+------------------+------------------+------------------+| 3500 53 | 7700 1350 | 12300 88 | 17700 9343 || 3600 1914 | 7800 695 | 12400 252 | 17800 381 || 3700 12535 | 7900 5782 | 12500 148 | 18000 35 || 3800 10760 | 8000 1455 | 12700 282 | 18300 181 || 3900 3962 | 8100 5745 | 12800 338 | 18600 248 |+------------------+------------------+------------------+------------------+| 4100 387 | 8200 905 | 12900 75 | 18700 80 || 4400 707 | 8300 42 | 13000 926 | 18800 162 || 4500 1464 | 8500 229 | 13100 166 | 18900 142 || 4600 281 | 8600 239 | 13200 7 | 19100 151 || 4700 3334 | 8700 7427 | 13400 27 | 19200 54 |+------------------+------------------+------------------+------------------+| 4800 1491 | 8800 7774 | 13700 332 | 19300 44 || 4900 8401 | 9100 1022 | 13800 172 | 19400 110 || 5000 42624 | 9200 5845 | 14000 185 | 19600 46 || 5100 13346 | 9300 8046 | 14100 1957 | 19800 171 || 5200 539 | 9400 21672 | 14200 53 | 20000 162 |+------------------+------------------+------------------+------------------+| 5300 13 | 9500 195072 | 14300 1698 | 20200 62 || 5400 14 | 9600 12530 | 14400 295 | 20300 48 || 5500 230 | 9700 551 | 14500 186 | 20400 104 || 5600 3600 | 9900 79 | 14600 115 | 20500 34 || 5700 5500 | 10000 36 | 14700 156 | 20700 223 |+------------------+------------------+------------------+------------------+| 5800 113 | 10100 136 | 14800 465 | 20900 81 || 5900 106 | 10200 36 | 14900 118 | 21500 80 || 6000 1861 | 10300 237 | 15000 105 | 21900 89 || 6100 10125 | 10400 905 | 15300 459 | 22000 60 || 6200 9219 | 10500 514 | 15400 192 | 22600 84 |+------------------+------------------+------------------+------------------+| 6300 7541 | 10600 1054 | 15700 390 | 23000 188 || 6400 270 | 10700 304 | 16000 378 | 23100 74 || 6500 625 | 11000 398 | 16100 530 | 23500 107 || 6600 51 | 11100 151 | 16400 54 | 23900 43 || 6700 378 | 11200 121 | 16700 172 | 24600 123 |+------------------+------------------+------------------+------------------+| 6800 20496 | 11300 247 | 16800 205 | 24700 37 || 6900 19976 | 11500 421 | 16900 243 | 25000 57 || 7000 1570 | 11600 358 | 17000 351 | 25200 33 || 7200 740 | 11700 1343 | 17100 439 | 25500 46 || 7300 9006 | 11800 855 | 17200 227 | 26200 43 |+------------------+------------------+------------------+------------------+| 7400 34320 | 11900 733 | 17400 155200 | 26400 63 || 7500 102376 | 12100 68 | 17500 12902 | 26500 45 || 7600 8204 | 12200 77 | 17600 148480 | |+------------------+------------------+------------------+------------------+

10162012Page 109 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08975d Report Date 11-Oct-2012 2012

TestAmerica

Data file chemVOAMS5i8260DE09-17-1211oct12be08975dLab Smp Id BFB Inj Date 11-OCT-2012 2008 Operator VOAMS 1 Inst ID VOAMS5iSmp Info BFBMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12bBFBDELmMeth Date 27-Feb-2012 1508 sylvanus Quant Type ISTDCal Date Cal File Als bottle 2 QC Sample BFBDil Factor 100000 Integrator HP RTE Compound Sublist allsubTarget Version 350 Sample Matrix WATERProcessing Host hpd2

Concentration Formula Amt DF Uf Vf VI CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorUf 100000 ng unit correction factorVf 100000 Volumetric correction factorVI 100000 Injection Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT (REL RT) MASS RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ==== ======== ======= ======= ============ =====

1 BFB CAS 460-00-4

2352 2600 (0000) 95 135522 000- 10000 10000

2352 2600 (0000) 50 29541 1500- 4000 2180

2352 2600 (0000) 75 70179 3000- 6000 5178

2352 2600 (0000) 96 8846 500- 900 653

2352 2600 (0000) 173 896 000- 200 074

2352 2600 (0000) 174 121433 5000- 10000 8960

2352 2600 (0000) 175 9704 500- 900 799

2352 2600 (0000) 176 118148 9500- 10100 9729

2352 2600 (0000) 177 7241 500- 900 613

-------------------------------------------------------------------------------

10162012Page 110 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

10162012Page 111 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

1 BFB

RELATIVE me ION ABUNDANCE CRITERIA ABUNDANCE

+-----+------------------------------------------+---------------------+| | | || 95 | Base Peak 100 relative abundance | 10000 || 50 | 1500 - 4000 of mass 95 | 2180 || 75 | 3000 - 6000 of mass 95 | 5178 || 96 | 500 - 900 of mass 95 | 653 || 173 | Less than 200 of mass 174 | 066 ( 074) || 174 | 5000 - 10000 of mass 95 | 8960 || 175 | 500 - 900 of mass 174 | 716 ( 799) || 176 | 9500 - 10100 of mass 174 | 8718 ( 9729) || 177 | 500 - 900 of mass 176 | 534 ( 613) |+-----+------------------------------------------+---------------------+

10162012Page 112 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

Data File chemVOAMS5i8260DE09-17-1211oct12be08975dSpectrum Avg Scans 50-52 ( 235) Background Scan 46

Location of Maximum 9500Number of points 149

mz Y mz Y mz Y mz Y+------------------+------------------+------------------+------------------+| 3600 1294 | 7800 45 | 13100 382 | 18200 69 || 3700 8431 | 7900 4274 | 13200 84 | 18300 115 || 3800 6991 | 8000 1313 | 13400 26 | 18600 116 || 3900 2548 | 8100 3602 | 13500 465 | 18700 340 || 4000 550 | 8200 868 | 13600 63 | 18800 34 |+------------------+------------------+------------------+------------------+| 4100 253 | 8300 128 | 13700 225 | 18900 18 || 4200 100 | 8400 171 | 13900 69 | 19900 265 || 4400 553 | 8500 53 | 14000 115 | 20100 29 || 4500 1283 | 8700 5211 | 14100 1442 | 20400 84 || 4700 1587 | 8800 4550 | 14200 269 | 20500 33 |+------------------+------------------+------------------+------------------+| 4800 651 | 9100 642 | 14300 1465 | 20600 138 || 4900 5880 | 9200 3657 | 14400 23 | 20700 20 || 5000 29536 | 9300 6715 | 14500 103 | 20900 79 || 5100 8612 | 9400 15687 | 14700 151 | 21000 74 || 5200 396 | 9500 135488 | 14800 365 | 21100 1 |+------------------+------------------+------------------+------------------+| 5300 107 | 9600 8846 | 14900 429 | 21200 140 || 5500 726 | 9700 271 | 15100 54 | 21300 52 || 5600 1691 | 9800 1 | 15300 430 | 21400 189 || 5700 4463 | 10000 110 | 15400 385 | 22100 72 || 5800 245 | 10300 207 | 15500 1021 | 22200 35 |+------------------+------------------+------------------+------------------+| 5900 116 | 10400 668 | 15600 236 | 22400 188 || 6000 1281 | 10600 562 | 15700 473 | 22600 79 || 6100 6975 | 10700 159 | 15800 3 | 22800 39 || 6200 7260 | 11000 145 | 15900 410 | 23000 95 || 6300 5465 | 11100 68 | 16100 441 | 23300 189 |+------------------+------------------+------------------+------------------+| 6400 672 | 11200 80 | 16400 208 | 23400 42 || 6500 144 | 11300 261 | 16500 57 | 23500 36 || 6600 201 | 11600 813 | 17000 641 | 23600 58 || 6700 729 | 11700 882 | 17100 38 | 24100 103 || 6800 14333 | 11800 446 | 17200 338 | 24700 36 |+------------------+------------------+------------------+------------------+| 6900 14506 | 11900 1049 | 17300 896 | 25100 40 || 7000 1361 | 12000 38 | 17400 121432 | 25500 61 || 7200 782 | 12100 249 | 17500 9704 | 25600 33 || 7300 6586 | 12400 108 | 17600 118144 | 26000 59 || 7400 24016 | 12600 138 | 17700 7241 | 26500 78 |+------------------+------------------+------------------+------------------+| 7500 70176 | 12700 39 | 17900 19 | || 7600 5444 | 12900 479 | 18000 29 | || 7700 507 | 13000 702 | 18100 322 | |+------------------+------------------+------------------+------------------+

10162012Page 113 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014U1634-04-4 Methyl tert-butyl ether 014

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 114 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

99 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

95 70-130460-00-4 4-Bromofluorobenzene

96 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 115 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 116 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08981d Report Date 12-Oct-2012 0041

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08981dLab Smp Id MB Inj Date 11-OCT-2012 2247 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info MBMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 6 QC Sample BLANKDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 381607 495518 50

52 Fluorobenzene 96 3595 3601 (1000) 1238441 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1209056 482553 48

78 Chlorobenzene-d5 117 6954 6954 (1000) 1084553 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 494380 477044 48

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 638826 500000

10162012Page 117 of 323

Data File e08981d

Date 11-OCT-2012 2247

Client ID Instrument VOAMS5i

Sample Info MB Operator GCMS VOAMS5

10162012Page 118 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1316563

Matrix e08977dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2113

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 006071-55-6 111-Trichloroethane 210

10 02275-71-8 Dichlorodifluoromethane 181

10 01074-87-3 Chloromethane 210

10 01475-01-4 Vinyl chloride 203

10 01874-83-9 Bromomethane 211

10 04096-12-8 12-Dibromo-3-Chloropropane 222

10 02195-50-1 12-Dichlorobenzene 209

10 01575-69-4 Trichlorofluoromethane 190

10 009075-35-4 11-Dichloroethene 223

10 009078-87-5 12-Dichloropropane 211

10 008076-13-1 112-Trichloro-122-trifluoroethane

203

50 2767-64-1 Acetone 250

10 01375-15-0 Carbon disulfide 218

20 03479-20-9 Methyl acetate 220

10 01875-09-2 Methylene Chloride 200

10 013156-60-5 trans-12-Dichloroethene 216

10 020124-48-1 Chlorodibromomethane 217

10 0141634-04-4 Methyl tert-butyl ether 207

10 01775-00-3 Chloroethane 201

10 01375-34-3 11-Dichloroethane 204

10 018156-59-2 cis-12-Dichloroethene 211

50 2378-93-3 2-Butanone (MEK) 214

10 008067-66-3 Chloroform 205

10 010100-41-4 Ethylbenzene 206

10 016110-82-7 Cyclohexane 208

10 006056-23-5 Carbon tetrachloride 211

10 008071-43-2 Benzene 212

10 019107-06-2 12-Dichloroethane 204

10 009079-01-6 Trichloroethene 212

10 014108-87-2 Methylcyclohexane 215

10 01275-27-4 Dichlorobromomethane 214

10 01810061-01-5 cis-13-Dichloropropene 216

50 099108-10-1 4-Methyl-2-pentanone (MIBK) 214

10 015108-88-3 Toluene 205

10 02410061-02-6 trans-13-Dichloropropene 215

FORM I 8260B

10162012Page 119 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1316563

Matrix e08977dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2113

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 01979-00-5 112-Trichloroethane 217

10 010127-18-4 Tetrachloroethene 210

50 050591-78-6 2-Hexanone 201

10 028106-93-4 12-Dibromoethane 215

10 011108-90-7 Chlorobenzene 206

30 0361330-20-7 Xylenes Total 612

10 012100-42-5 Styrene 207

10 01975-25-2 Bromoform 217

10 008098-82-8 Isopropylbenzene 207

10 01679-34-5 1122-Tetrachloroethane 210

10 014541-73-1 13-Dichlorobenzene 204

10 023106-46-7 14-Dichlorobenzene 204

10 034120-82-1 124-Trichlorobenzene 220

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

97 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 120 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08977d Report Date 11-Oct-2012 2301

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08977dLab Smp Id LCS Inj Date 11-OCT-2012 2113 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info LCSMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 2 QC Sample BSDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 92905 180886 18

3 Chloromethane 50 1016 1016 (0283) 178821 210339 21

4 Vinyl Chloride 62 1022 1028 (0284) 146748 202753 20

6 Bromomethane 94 1181 1181 (0328) 88580 210689 21

5 Chloroethane 64 1236 1242 (0344) 67759 201399 20

7 Trichlorofluoromethane 101 1297 1303 (0361) 148657 190423 19

14 Freon TF 101 1565 1577 (0435) 106548 203057 20

15 11-Dichloroethene 96 1547 1553 (0430) 94737 223085 22

16 Acetone 58 1900 1894 (0529) 14083 249674 25

18 Carbon Disulfide 76 1565 1571 (0435) 377236 218062 22

27 Methyl Acetate 74 1961 1967 (0546) 21873 219755 22

22 Methylene Chloride 49 1858 1864 (0517) 180593 200499 20

28 MTBE 73 2022 2022 (0562) 363998 207251 21

25 trans-12-Dichloroethene 96 1943 1949 (0540) 119022 216004 22

30 11-Dichloroethane 63 2303 2309 (0640) 238759 204130 20

36 cis-12-Dichloroethene 96 2650 2656 (0737) 126688 211021 21

10162012Page 121 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08977d Report Date 11-Oct-2012 2301

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 20020 214276 21

42 Chloroform 83 2845 2845 (0791) 215227 205163 20

44 Cyclohexane 56 2778 2784 (0773) 186275 208395 21

43 111-Trichloroethane 97 2979 2985 (0829) 195599 210453 21

45 Carbon Tetrachloride 117 2931 2937 (0815) 156464 210644 21

48 Benzene 78 3260 3260 (0469) 500200 211727 21

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 391700 477589 48

49 12-Dichloroethane 62 3412 3418 (0949) 178793 204379 20

52 Fluorobenzene 96 3595 3601 (1000) 1318918 500000

54 Trichloroethene 95 3735 3741 (1039) 127803 211922 21

56 Methyl cyclohexane 83 3723 3729 (1036) 159134 214991 21

57 12-Dichloropropane 63 4192 4199 (1166) 134808 211159 21

68 Bromodichloromethane 83 4272 4272 (1188) 171399 214054 21

67 cis-13-Dichloropropene 75 4906 4912 (0705) 217526 216258 22

70 4-Methyl-2-Pentanone 43 5631 5625 (0810) 134218 214248 21

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1312817 495616 50

66 Toluene 91 5162 5162 (0742) 572353 205343 20

64 trans-13-Dichloropropene 75 5650 5649 (0812) 195539 215018 22

69 112-Trichloroethane 83 5820 5820 (0837) 92220 217218 22

71 Tetrachloroethene 166 5582 5582 (0803) 145712 209847 21

73 2-Hexanone 43 6680 6680 (0961) 96649 200980 20

74 Dibromochloromethane 129 6015 6021 (0865) 132048 217333 22

77 12-Dibromoethane 107 6259 6265 (0900) 113742 214758 21

78 Chlorobenzene-d5 117 6954 6954 (1000) 1146590 500000

79 Chlorobenzene 112 6972 6972 (1003) 392243 206030 21

81 Ethylbenzene 106 7064 7064 (1016) 206211 205716 20

82 m+p-Xylene 106 7277 7277 (1046) 519872 407882 41

84 o-Xylene 106 7856 7862 (1130) 254939 203845 20

85 Styrene 104 7942 7942 (1142) 437977 207191 21

86 Bromoform 173 7911 7911 (1138) 93696 217219 22

88 Isopropylbenzene 105 8344 8350 (1200) 637526 207206 21

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 538047 484974 48

92 1122-Tetrachloroethane 83 9112 9112 (0871) 147339 210261 21

105 13-Dichlorobenzene 146 10325 10331 (0987) 330263 203584 20

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 683882 500000

109 14-Dichlorobenzene 146 10484 10490 (1002) 343961 204369 20

111 12-Dichlorobenzene 146 11148 11148 (1065) 320073 208797 21

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 26198 222454 22

114 124-Trichlorobenzene 180 12977 12977 (1240) 189475 219787 22

M 120 12-Dichloroethene (Total) 100 245711 427025 43

M 121 Xylene (Total) 100 774811 611727 61

10162012Page 122 of 323

Data File e08977d

Date 11-OCT-2012 2113

Client ID Instrument VOAMS5i

Sample Info LCS Operator GCMS VOAMS5

10162012Page 123 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MS

Matrix e08985dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0027

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 03071-55-6 111-Trichloroethane 103

50 1175-71-8 Dichlorodifluoromethane 865

50 05074-87-3 Chloromethane 102

50 07075-01-4 Vinyl chloride 104

50 09074-83-9 Bromomethane 107

50 2096-12-8 12-Dibromo-3-Chloropropane 121

50 1195-50-1 12-Dichlorobenzene 107

50 07575-69-4 Trichlorofluoromethane 121

50 04575-35-4 11-Dichloroethene 108

50 04578-87-5 12-Dichloropropane 111

50 04076-13-1 112-Trichloro-122-trifluoroethane

102

25 1367-64-1 Acetone 986

50 06575-15-0 Carbon disulfide 113

10 1779-20-9 Methyl acetate 100

50 09075-09-2 Methylene Chloride 106

50 065156-60-5 trans-12-Dichloroethene 106

50 10124-48-1 Chlorodibromomethane 116

50 0701634-04-4 Methyl tert-butyl ether 114

50 08575-00-3 Chloroethane 116

50 06575-34-3 11-Dichloroethane 104

50 090156-59-2 cis-12-Dichloroethene 105

25 1278-93-3 2-Butanone (MEK) 111

50 04067-66-3 Chloroform 108

50 050100-41-4 Ethylbenzene 107

50 080110-82-7 Cyclohexane 108

50 03056-23-5 Carbon tetrachloride 105

50 04071-43-2 Benzene 106

50 095107-06-2 12-Dichloroethane 107

50 04579-01-6 Trichloroethene 107

50 070108-87-2 Methylcyclohexane 115

50 06075-27-4 Dichlorobromomethane 113

50 09010061-01-5 cis-13-Dichloropropene 109

25 50108-10-1 4-Methyl-2-pentanone (MIBK) 111

50 075108-88-3 Toluene 106

50 1210061-02-6 trans-13-Dichloropropene 113

FORM I 8260B

10162012Page 124 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MS

Matrix e08985dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0027

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 09579-00-5 112-Trichloroethane 112

50 050127-18-4 Tetrachloroethene 110

25 25591-78-6 2-Hexanone 109

50 14106-93-4 12-Dibromoethane 116

50 055108-90-7 Chlorobenzene 107

15 181330-20-7 Xylenes Total 318

50 060100-42-5 Styrene 107

50 09575-25-2 Bromoform 115

50 04098-82-8 Isopropylbenzene 107

50 08079-34-5 1122-Tetrachloroethane 115

50 070541-73-1 13-Dichlorobenzene 106

50 12106-46-7 14-Dichlorobenzene 106

50 17120-82-1 124-Trichlorobenzene 110

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 125 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08985d Report Date 12-Oct-2012 0117

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08985dLab Smp Id 460-45537-C-2 MS Inj Date 12-OCT-2012 0027 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-C-2 MS5Misc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 10 QC Sample MSDil Factor 500000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 500000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 83204 173010 86

3 Chloromethane 50 1016 1016 (0283) 161645 203059 100

4 Vinyl Chloride 62 1022 1028 (0284) 141501 208792 100

6 Bromomethane 94 1181 1181 (0328) 84568 214819 110

5 Chloroethane 64 1236 1242 (0344) 73104 232055 120

7 Trichlorofluoromethane 101 1297 1303 (0361) 177163 242363 120

14 Freon TF 101 1571 1577 (0437) 100496 204542 100

15 11-Dichloroethene 96 1553 1553 (0432) 86070 216451 110

16 Acetone 58 1894 1894 (0527) 10416 197218 99

18 Carbon Disulfide 76 1565 1571 (0435) 366514 226264 110

27 Methyl Acetate 74 1961 1967 (0546) 18655 200164 100

22 Methylene Chloride 49 1857 1864 (0517) 178536 211689 100

28 MTBE 73 2016 2022 (0561) 376182 228747 110

25 trans-12-Dichloroethene 96 1949 1949 (0542) 109215 211677 100

30 11-Dichloroethane 63 2309 2309 (0642) 226749 207039 100

36 cis-12-Dichloroethene 96 2650 2656 (0737) 118569 210921 100

10162012Page 126 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08985d Report Date 12-Oct-2012 0117

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 19396 221710 110

42 Chloroform 83 2845 2845 (0791) 213034 216876 110

44 Cyclohexane 56 2784 2784 (0774) 180984 216238 110

43 111-Trichloroethane 97 2979 2985 (0829) 179996 206829 100

45 Carbon Tetrachloride 117 2930 2937 (0815) 145570 209299 100

48 Benzene 78 3260 3260 (0469) 482493 212344 110

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 369860 481613 48

49 12-Dichloroethane 62 3418 3418 (0951) 175178 213858 110

52 Fluorobenzene 96 3595 3601 (1000) 1234975 500000

54 Trichloroethene 95 3741 3741 (1041) 121196 214627 110

56 Methyl cyclohexane 83 3729 3729 (1037) 158792 229110 110

57 12-Dichloropropane 63 4192 4199 (1166) 132380 221450 110

68 Bromodichloromethane 83 4272 4272 (1188) 168703 225007 110

67 cis-13-Dichloropropene 75 4906 4912 (0705) 211819 218949 110

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 133223 221106 110

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1260222 494657 49

66 Toluene 91 5162 5162 (0742) 566751 211409 100

64 trans-13-Dichloropropene 75 5649 5649 (0812) 197737 226072 110

69 112-Trichloroethane 83 5820 5820 (0837) 91872 224994 110

71 Tetrachloroethene 166 5582 5582 (0803) 147320 220590 110

73 2-Hexanone 43 6674 6680 (0960) 100809 217957 110

74 Dibromochloromethane 129 6015 6021 (0865) 135240 231427 120

77 12-Dibromoethane 107 6259 6265 (0900) 117784 231222 120

78 Chlorobenzene-d5 117 6954 6954 (1000) 1102789 500000

79 Chlorobenzene 112 6972 6972 (1003) 391979 214069 110

81 Ethylbenzene 106 7064 7064 (1016) 207079 214786 110

82 m+p-Xylene 106 7277 7277 (1046) 521861 425705 210

84 o-Xylene 106 7856 7862 (1130) 254032 211187 100

85 Styrene 104 7942 7942 (1142) 433507 213222 110

86 Bromoform 173 7911 7911 (1138) 95433 230033 120

88 Isopropylbenzene 105 8350 8350 (1201) 635772 214844 110

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 518047 497030 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 151817 230609 120

105 13-Dichlorobenzene 146 10325 10331 (0987) 322106 211348 100

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 642491 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 334190 211356 100

111 12-Dichlorobenzene 146 11148 11148 (1065) 308704 214355 110

112 12-Dibromo-3-chloropropane 75 12233 12234 (1169) 26873 242889 120(R)

114 124-Trichlorobenzene 180 12977 12977 (1240) 177853 219597 110

M 120 12-Dichloroethene (Total) 100 227784 422599 210

M 121 Xylene (Total) 100 775893 636892 320

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 127 of 323

Data File e08985d

Date 12-OCT-2012 0027

Client ID Instrument VOAMS5i

Sample Info 460-45537-C-2 MS5 Operator GCMS VOAMS5

10162012Page 128 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MSD

Matrix e08986dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0051

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 03071-55-6 111-Trichloroethane 106

50 1175-71-8 Dichlorodifluoromethane 896

50 05074-87-3 Chloromethane 101

50 07075-01-4 Vinyl chloride 105

50 09074-83-9 Bromomethane 105

50 2096-12-8 12-Dibromo-3-Chloropropane 121

50 1195-50-1 12-Dichlorobenzene 111

50 07575-69-4 Trichlorofluoromethane 997

50 04575-35-4 11-Dichloroethene 119

50 04578-87-5 12-Dichloropropane 110

50 04076-13-1 112-Trichloro-122-trifluoroethane

111

25 1367-64-1 Acetone 101

50 06575-15-0 Carbon disulfide 119

10 1779-20-9 Methyl acetate 101

50 09075-09-2 Methylene Chloride 106

50 065156-60-5 trans-12-Dichloroethene 108

50 10124-48-1 Chlorodibromomethane 118

50 0701634-04-4 Methyl tert-butyl ether 116

50 08575-00-3 Chloroethane 105

50 06575-34-3 11-Dichloroethane 111

50 090156-59-2 cis-12-Dichloroethene 109

25 1278-93-3 2-Butanone (MEK) 114

50 04067-66-3 Chloroform 113

50 050100-41-4 Ethylbenzene 111

50 080110-82-7 Cyclohexane 117

50 03056-23-5 Carbon tetrachloride 110

50 04071-43-2 Benzene 114

50 095107-06-2 12-Dichloroethane 109

50 04579-01-6 Trichloroethene 113

50 070108-87-2 Methylcyclohexane 121

50 06075-27-4 Dichlorobromomethane 116

50 09010061-01-5 cis-13-Dichloropropene 115

25 50108-10-1 4-Methyl-2-pentanone (MIBK) 114

50 075108-88-3 Toluene 111

50 1210061-02-6 trans-13-Dichloropropene 119

FORM I 8260B

10162012Page 129 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MSD

Matrix e08986dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0051

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 09579-00-5 112-Trichloroethane 116

50 050127-18-4 Tetrachloroethene 116

25 25591-78-6 2-Hexanone 111

50 14106-93-4 12-Dibromoethane 117

50 055108-90-7 Chlorobenzene 111

15 181330-20-7 Xylenes Total 329

50 060100-42-5 Styrene 110

50 09575-25-2 Bromoform 114

50 04098-82-8 Isopropylbenzene 111

50 08079-34-5 1122-Tetrachloroethane 116

50 070541-73-1 13-Dichlorobenzene 110

50 12106-46-7 14-Dichlorobenzene 110

50 17120-82-1 124-Trichlorobenzene 119

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

97 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 130 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08986d Report Date 12-Oct-2012 0118

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08986dLab Smp Id 460-45537-C-2 MSD Inj Date 12-OCT-2012 0051 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-C-2 MSD5Misc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 11 QC Sample MSDDil Factor 500000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 500000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 90471 179208 90

3 Chloromethane 50 1016 1016 (0283) 169425 202751 100

4 Vinyl Chloride 62 1022 1028 (0284) 149176 209689 100

6 Bromomethane 94 1181 1181 (0328) 86595 209548 100

5 Chloroethane 64 1236 1242 (0344) 69668 210673 100

7 Trichlorofluoromethane 101 1297 1303 (0361) 152935 199307 100

14 Freon TF 101 1565 1577 (0435) 114134 221294 110

15 11-Dichloroethene 96 1547 1553 (0430) 98966 237094 120

16 Acetone 58 1900 1894 (0529) 11165 201386 100

18 Carbon Disulfide 76 1565 1571 (0435) 405349 238385 120

27 Methyl Acetate 74 1961 1967 (0546) 19684 201192 100

22 Methylene Chloride 49 1858 1864 (0517) 187993 212342 110

28 MTBE 73 2022 2022 (0562) 399850 231621 120(R)

25 trans-12-Dichloroethene 96 1943 1949 (0540) 117162 216323 110

30 11-Dichloroethane 63 2309 2309 (0642) 255983 222660 110

36 cis-12-Dichloroethene 96 2650 2656 (0737) 129220 218978 110

10162012Page 131 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08986d Report Date 12-Oct-2012 0118

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 20938 227991 110

42 Chloroform 83 2845 2845 (0791) 233404 226357 110

44 Cyclohexane 56 2778 2784 (0773) 204751 233046 120

43 111-Trichloroethane 97 2979 2985 (0829) 194508 212915 110

45 Carbon Tetrachloride 117 2931 2937 (0815) 161111 220670 110

48 Benzene 78 3260 3260 (0469) 525066 227601 110

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 386156 479012 48

49 12-Dichloroethane 62 3412 3418 (0949) 188223 218898 110

52 Fluorobenzene 96 3595 3601 (1000) 1296388 500000

54 Trichloroethene 95 3741 3741 (1041) 133629 225434 110

56 Methyl cyclohexane 83 3723 3729 (1036) 175741 241553 120

57 12-Dichloropropane 63 4192 4199 (1166) 138376 220515 110

68 Bromodichloromethane 83 4272 4272 (1188) 182026 231276 120

67 cis-13-Dichloropropene 75 4906 4912 (0705) 226245 230339 120

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 139423 227913 110

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1279885 494812 49

66 Toluene 91 5162 5162 (0742) 602122 221221 110

64 trans-13-Dichloropropene 75 5650 5649 (0812) 211878 238592 120(R)

69 112-Trichloroethane 83 5820 5820 (0837) 95786 231047 120

71 Tetrachloroethene 166 5582 5582 (0803) 157152 231769 120

73 2-Hexanone 43 6680 6680 (0961) 103997 221464 110

74 Dibromochloromethane 129 6015 6021 (0865) 140562 236912 120

77 12-Dibromoethane 107 6259 6265 (0900) 120913 233791 120

78 Chlorobenzene-d5 117 6954 6954 (1000) 1119645 500000

79 Chlorobenzene 112 6972 6972 (1003) 411739 221475 110

81 Ethylbenzene 106 7064 7064 (1016) 216984 221672 110

82 m+p-Xylene 106 7277 7277 (1046) 549474 441482 220

84 o-Xylene 106 7856 7862 (1130) 265488 217389 110

85 Styrene 104 7942 7942 (1142) 452927 219420 110

86 Bromoform 173 7911 7911 (1138) 96039 228008 110

88 Isopropylbenzene 105 8344 8350 (1200) 668990 222665 110

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 517679 487311 49

92 1122-Tetrachloroethane 83 9112 9112 (0871) 155509 231763 120

105 13-Dichlorobenzene 146 10325 10331 (0987) 342279 220349 110

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 654839 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 355256 220442 110

111 12-Dichlorobenzene 146 11148 11148 (1065) 324646 221173 110

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 27355 242581 120(R)

114 124-Trichlorobenzene 180 12977 12977 (1240) 196651 238228 120

M 120 12-Dichloroethene (Total) 100 246382 435302 220

M 121 Xylene (Total) 100 814963 658871 330

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 132 of 323

Data File e08986d

Date 12-OCT-2012 0051

Client ID Instrument VOAMS5i

Sample Info 460-45537-C-2 MSD5 Operator GCMS VOAMS5

10162012Page 133 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GCMS VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

VOAMS5

128076

Start Date

End Date 09172012 1616

09172012 0324

BFB 460-1280761 Rtx-VMS 018(mm)109172012 0324 e07834d

IC 460-1280762 Rtx-VMS 018(mm)109172012 0449 e07836d

IC 460-1280763 Rtx-VMS 018(mm)109172012 0536 e07838d

ICIS 460-1280764 Rtx-VMS 018(mm)109172012 0600 e07839d

IC 460-1280765 Rtx-VMS 018(mm)109172012 0623 e07840d

IC 460-1280766 Rtx-VMS 018(mm)109172012 0646 e07841d

IC 460-1280767 Rtx-VMS 018(mm)109172012 0710 e07842d

ZZZZZ Rtx-VMS 018(mm)109172012 0937

ZZZZZ Rtx-VMS 018(mm)109172012 1047

ZZZZZ Rtx-VMS 018(mm)109172012 1111

ZZZZZ Rtx-VMS 018(mm)109172012 1134

ZZZZZ Rtx-VMS 018(mm)109172012 1157

ZZZZZ Rtx-VMS 018(mm)509172012 1221

ZZZZZ Rtx-VMS 018(mm)509172012 1244

ZZZZZ Rtx-VMS 018(mm)109172012 1307

ZZZZZ Rtx-VMS 018(mm)109172012 1331

ZZZZZ Rtx-VMS 018(mm)109172012 1354

ZZZZZ Rtx-VMS 018(mm)109172012 1417

ZZZZZ Rtx-VMS 018(mm)109172012 1441

CCV 460-12807620 Rtx-VMS 018(mm)109172012 1616

8260B

10162012Page 134 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GCMS VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

VOAMS5

131656

Start Date

End Date 10122012 0114

10112012 2008

BFB 460-1316561 Rtx-VMS 018(mm)110112012 2008 e08975d

CCVIS 460-1316562 Rtx-VMS 018(mm)110112012 2050 e08976d

LCS 460-1316563 Rtx-VMS 018(mm)110112012 2113 e08977d

MB 460-1316564 Rtx-VMS 018(mm)110112012 2247 e08981d

460-45537-3 TB-17338-100512-253 Rtx-VMS 018(mm)110112012 2317 e08982d

460-45537-1 WC-17338-100512-MW14-MM-251

Rtx-VMS 018(mm)110112012 2341 e08983d

460-45537-2 WC-17338-100512-MW101-MM-252

Rtx-VMS 018(mm)110122012 0004 e08984d

460-45537-2 MS WC-17338-100512-MW101-MM-252 MS

Rtx-VMS 018(mm)510122012 0027 e08985d

460-45537-2 MSD WC-17338-100512-MW101-MM-252 MSD

Rtx-VMS 018(mm)510122012 0051 e08986d

CCV 460-13165610 Rtx-VMS 018(mm)110122012 0114 e08987d

8260B

10162012Page 135 of 323

10162012Page 136 of 323

10162012Page 137 of 323

10162012Page 138 of 323

10162012Page 139 of 323

Method 8082 -

DelawarePolychlorinated Biphenyls (PCBs)

(GC) by Method 8082 (Delaware)

10162012Page 140 of 323

FORM II

GC SEMI VOA SURROGATE RECOVERY

Lab Name Job No 460-45537-1

SDG No

Matrix Water Level Low

TestAmerica Edison

GC Column (1) ID (mm) GC Column (2) ID (mm)CLP-1 053 CLP-2 053

Lab Sample IDClient Sample ID DCB1 DCB2

460-45537-1WC-17338-100512-MW14-MM-251

82 83

460-45537-2WC-17338-100512-MW101-MM-252

52 50

MB 460-1309971-A

97 88

LCS 460-1309972-A

91 84

LCSD 460-1309973-A

108 99

QC LIMITSQC LIMITSDCB = DCB Decachlorobiphenyl 37-150

FORM II 8082

Column to be used to flag recovery values

10162012Page 141 of 323

GC SEMI VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vf479497dWater

Lab ID LCS 460-1309972-A Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

PCB-1016 500 507 71-126101

PCB-1260 500 557 73-130111

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 142 of 323

GC SEMI VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vr479497dWater

Lab ID LCS 460-1309972-A Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

PCB-1016 500 483 71-12697

PCB-1260 500 573 73-130115

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 143 of 323

GC SEMI VOA LAB CONTROL SAMPLE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vf479498dWater

Lab ID LCSD 460-1309973-A Client ID

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

LCSD LCSD

500 516 30 71-126PCB-1016 2103

500 583 30 73-130PCB-1260 5117

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 144 of 323

GC SEMI VOA LAB CONTROL SAMPLE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vr479498dWater

Lab ID LCSD 460-1309973-A Client ID

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

LCSD LCSD

500 497 30 71-126PCB-1016 399

500 595 30 73-130PCB-1260 4119

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 145 of 323

FORM IV

GC SEMI VOA METHOD BLANK SUMMARY

Lab Name

SDG No

Job No 460-45537-1TestAmerica Edison

Date Analyzed(1)

Instrument ID(1)

GC Column(1) ID

Instrument ID(2)

Date Extracted 10082012 0755

Date Analyzed(2)

GC Column(2) IDCLP-2053(mm) 053(mm)

PESTGC9

10082012 2208

Lab File ID(1) Lab File ID(2)

Matrix Water

vf479496d

Lab Sample ID MB 460-1309971-A

vr479496d

10082012 2208

PESTGC9

CLP-1

THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES

ANALYZED 2

DATEDATE

ANALYZED 1LAB SAMPLE IDCLIENT SAMPLE ID

LCS 460-1309972-A 10082012 2224 10082012 2224

LCSD 460-1309973-A 10082012 2239 10082012 2239

460-45537-1WC-17338-100512-MW14-MM-251

10092012 0029 10092012 0029

460-45537-2WC-17338-100512-MW101-MM-252

10092012 0045 10092012 0045

FORM IV 8082

10162012Page 146 of 323

GC SEMI VOA ANALYTICAL SEQUENCE

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVRT 460-1311372 Date Analyzed 10082012 1830

Lab File ID (Standard) vf479493d

Instrument ID PESTGC9 GC Column CLP-2 ID 053(mm)

Heated Purge (YN) N

Calibration ID 17840

THE ANALYTICAL SEQUENCE OF BLANKS SAMPLES STANDARDS MSMSDs AND LCSs IS GIVEN BELOW

RT

DCB

UPPER LIMIT

LOWER LIMIT

1159

1139

CONTINUING CALIBRATION SURROGATE 1149

LAB SAMPLE ID DATE ANALYZEDCLIENT SAMPLE ID LAB FILE ID

CCVRT 460-1311372 10082012 1830 1149vf479493d

MB 460-1309971-A 10082012 2208 1148vf479496d

LCS 460-1309972-A 10082012 2224 1148vf479497d

LCSD 460-1309973-A 10082012 2239 1148vf479498d

460-45537-1 10092012 0029 1149WC-17338-100512-MW14-MM-251

vf479505d

460-45537-2 10092012 0045 1149WC-17338-100512-MW101-MM-252

vf479506d

PIBLK 460-13113718 10092012 0131 1149vf479509d

CCV 460-13113719 10092012 0147 1149vf479510d

DCB = DCB Decachlorobiphenyl

DCB RT Limit = plusmn 01 minutes of surrogate RT

Column used to flag values outside QC limits

FORM VIII 8082

10162012Page 147 of 323

GC SEMI VOA ANALYTICAL SEQUENCE

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVRT 460-1311372 Date Analyzed 10082012 1830

Lab File ID (Standard) vr479493d

Instrument ID PESTGC9 GC Column CLP-1 ID 053(mm)

Heated Purge (YN) N

Calibration ID 17839

THE ANALYTICAL SEQUENCE OF BLANKS SAMPLES STANDARDS MSMSDs AND LCSs IS GIVEN BELOW

RT

DCB

UPPER LIMIT

LOWER LIMIT

1071

1051

CONTINUING CALIBRATION SURROGATE 1061

LAB SAMPLE ID DATE ANALYZEDCLIENT SAMPLE ID LAB FILE ID

CCVRT 460-1311372 10082012 1830 1061vr479493d

MB 460-1309971-A 10082012 2208 1061vr479496d

LCS 460-1309972-A 10082012 2224 1061vr479497d

LCSD 460-1309973-A 10082012 2239 1061vr479498d

460-45537-1 10092012 0029 1061WC-17338-100512-MW14-MM-251

vr479505d

460-45537-2 10092012 0045 1061WC-17338-100512-MW101-MM-252

vr479506d

PIBLK 460-13113718 10092012 0131 1061vr479509d

CCV 460-13113719 10092012 0147 1061vr479510d

DCB = DCB Decachlorobiphenyl

DCB RT Limit = plusmn 01 minutes of surrogate RT

Column used to flag values outside QC limits

FORM VIII 8082

10162012Page 148 of 323

FORM XForm 1

Client Sample ID

Lab Name Job No

SDG No

Lab Sample ID LCS 460-1309972-A

Instrument ID (1) Instrument ID (2)

Date Analyzed (1) Date Analyzed (2)

GC Column (1) ID GC Column (2) ID

TestAmerica Edison 460-45537-1

IDENTIFICATION SUMMARYForm 1

053(mm) 053(mm)

10082012 2224 10082012 2224

PESTGC9 PESTGC9

CLP-1 CLP-2

ANALYTE COL PEAK RTRT WINDOW

FROM TO PEAK MEAN

CONCENTRATIONRPD

PCB-1016 1 1 206 201 215 473 483 47

2 250 246 260 494

3 275 271 285 530

4 310 306 320 501

5 330 326 340 520

6 369 361 375 302

7 401 397 411 541

8 419 412 426 505

2 1 293 289 303 525 507

2 360 357 371 562

3 404 401 415 567

4 444 441 455 558

5 468 465 479 594

6 518 509 523 402

7 557 547 561 259

8 571 568 582 584

PCB-1260 1 1 605 600 614 554 573 28

2 650 645 659 558

3 694 689 703 581

4 714 709 723 548

5 758 753 767 565

6 886 882 896 559

7 908 904 918 619

8 1014 1008 1022 600

2 1 771 769 783 600 557

2 817 814 828 594

3 903 901 915 625

4 928 926 940 622

5 941 938 952 643

6 986 983 997 612

7 1062 1055 1069 212

8 1106 1102 1116 550

FORM X 8082

10162012Page 149 of 323

FORM XForm 1

Client Sample ID

Lab Name Job No

SDG No

Lab Sample ID LCSD 460-1309973-A

Instrument ID (1) Instrument ID (2)

Date Analyzed (1) Date Analyzed (2)

GC Column (1) ID GC Column (2) ID

TestAmerica Edison 460-45537-1

IDENTIFICATION SUMMARYForm 1

053(mm) 053(mm)

10082012 2239 10082012 2239

PESTGC9 PESTGC9

CLP-1 CLP-2

ANALYTE COL PEAK RTRT WINDOW

FROM TO PEAK MEAN

CONCENTRATIONRPD

PCB-1016 1 1 206 201 215 483 497 38

2 250 246 260 505

3 275 271 285 542

4 310 306 320 510

5 330 326 340 529

6 368 361 375 369

7 401 397 411 549

8 419 412 426 491

2 1 292 289 303 535 516

2 359 357 371 574

3 404 401 415 572

4 443 441 455 572

5 468 465 479 606

6 518 509 523 407

7 557 547 561 267

8 571 568 582 599

PCB-1260 1 1 605 600 614 565 595 19

2 650 645 659 571

3 694 689 703 595

4 714 709 723 563

5 757 753 767 585

6 886 882 896 582

7 908 904 918 656

8 1014 1008 1022 639

2 1 771 769 783 615 583

2 816 814 828 610

3 902 901 915 645

4 928 926 940 648

5 940 938 952 669

6 986 983 997 637

7 1062 1055 1069 253

8 1106 1102 1116 590

FORM X 8082

10162012Page 150 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix vf479505dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1000

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0029

5(mL)

Sample wtvol 980(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

83 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 151 of 323

Data File vf479505d Report Date 09-Oct-2012 0313

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479505dLab Smp Id 460-45537-E-1-B Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0029 Operator Inst ID PESTGC9iSmp Info 460-45537-E-1-BMisc Info 460-45537-E-1-BComment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 35 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 98000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11489 11515 -0026 22061081 829479 042 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 152 of 323

Data File vf479505d

Date 09-OCT-2012 0029

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-1-B Operator

10162012Page 153 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix vr479505dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1000

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0029

5(mL)

Sample wtvol 980(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

051 013U12674-11-2 PCB-1016 013

051 029U11104-28-2 PCB-1221 029

051 012U11141-16-5 PCB-1232 012

051 012U53469-21-9 PCB-1242 012

051 024U12672-29-6 PCB-1248 024

051 017U11097-69-1 PCB-1254 017

051 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

82 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 154 of 323

Data File vr479505d Report Date 09-Oct-2012 0303

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479505dLab Smp Id 460-45537-E-1-B Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0029 Operator Inst ID PESTGC9iSmp Info 460-45537-E-1-BMisc Info 460-45537-E-1-BComment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 35 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 98000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 38407031 815954 042 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 155 of 323

Data File vr479505d

Date 09-OCT-2012 0029

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-1-B Operator

10162012Page 156 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix vf479506dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1230

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0045

5(mL)

Sample wtvol 990(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

50 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 157 of 323

Data File vf479506d Report Date 09-Oct-2012 0322

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479506dLab Smp Id 460-45537-E-2-A Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0045 Operator Inst ID PESTGC9iSmp Info 460-45537-E-2-AMisc Info 460-45537-E-2-AComment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 36 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 99000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11487 11515 -0028 13346591 501821 025 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 158 of 323

Data File vf479506d

Date 09-OCT-2012 0045

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-2-A Operator

10162012Page 159 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix vr479506dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1230

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0045

5(mL)

Sample wtvol 990(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

051 013U12674-11-2 PCB-1016 013

051 028U11104-28-2 PCB-1221 028

051 012U11141-16-5 PCB-1232 012

051 012U53469-21-9 PCB-1242 012

051 024U12672-29-6 PCB-1248 024

051 017U11097-69-1 PCB-1254 017

051 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

52 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 160 of 323

Data File vr479506d Page 1 Report Date 09-Oct-2012 0322

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479506dLab Smp Id 460-45537-E-2-A Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0045 Operator Inst ID PESTGC9iSmp Info 460-45537-E-2-AMisc Info 460-45537-E-2-AComment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 36 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 99000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 24675227 524223 026 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 161 of 323

Data File vr479506d

Date 09-OCT-2012 0045

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-2-A Operator

10162012Page 162 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vf479200dLevel 2 IC 460-1299268 vf479201dLevel 3 IC 460-1299269 vf479202dLevel 4 IC 460-12992610 vf479203dLevel 5 IC 460-12992611 vf479204d

ANALYTE LVL 1 LVL 2 LVL 3 LVL 4 LVL 5 AVG RTRT WINDOW

PCB-1016 Peak 1 29602891 - 30312960 2960 2961 2959 2959PCB-1016 Peak 2 36403571 - 37113640 3640 3641 3639 3640PCB-1016 Peak 3 40844015 - 41554084 4084 4085 4083 4083PCB-1016 Peak 4 44774409 - 45494477 4477 4479 4477 4476PCB-1016 Peak 5 47224652 - 47924722 4722 4722 4722 4722PCB-1016 Peak 6 51575088 - 52285157 5158 5158 5157 5157PCB-1016 Peak 7 55425472 - 56125542 5543 5542 5542 5542PCB-1016 Peak 8 57515682 - 58225751 5751 5752 5751 5751PCB-1260 Peak 1 77567686 - 78267756 7756 7756 7756 7755PCB-1260 Peak 2 82158145 - 82858216 8215 8215 8215 8215PCB-1260 Peak 3 90839014 - 91549084 9084 9084 9083 9082PCB-1260 Peak 4 93329262 - 94029332 9332 9332 9332 9331PCB-1260 Peak 5 94549384 - 95249454 9454 9454 9454 9453PCB-1260 Peak 6 99019831 - 99719901 9901 9901 9901 9901PCB-1260 Peak 7 1061710546 - 1068610617 10617 10616 10617 10616PCB-1260 Peak 8 1108611016 - 1115611087 11087 11086 11084 11085DCB Decachlorobiphenyl 1151511415 - 1161511518 11520 11515 11510 11512

FORM VI 8082 10162012Page 163 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1299267 vf479200d2Level IC 460-1299268 vf479201d3Level IC 460-1299269 vf479202d4Level IC 460-12992610 vf479203d5Level IC 460-12992611 vf479204d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1016 Peak 1 Ave 155 20012858 10484 96475 9762186122

102726535

PCB-1016 Peak 2 Ave 122 20025248 21181 20808 2014318185

211130015

PCB-1016 Peak 3 Ave 124 20010359 90007 83526 8441074163

871400841

PCB-1016 Peak 4 Ave 130 20045579 38951 35291 3591632814

377100165

PCB-1016 Peak 5 Ave 129 20019485 17677 14821 1595214340

164548979

PCB-1016 Peak 6 Ave 171 20012410 10306 89543 9039281426

977025128

PCB-1016 Peak 7 Ave 161 20015097 12427 11165 1121510046

119900052

PCB-1016 Peak 8 Ave 121 20014456 12522 11609 1161310532

121463746

PCB-1260 Peak 1 Ave 165 20028165 22320 20852 2059718598

221063931

PCB-1260 Peak 2 Ave 173 20032398 25230 23518 2315121164

250922627

PCB-1260 Peak 3 Ave 101 20042792 37584 35706 3549332757

368665853

PCB-1260 Peak 4 Ave 114 20019125 16727 15681 1547514194

162405856

PCB-1260 Peak 5 Ave 71 20097407 90339 86445 8609680436

881445133

PCB-1260 Peak 6 Ave 116 20020218 16837 16387 1620514980

169255417

PCB-1260 Peak 7 Ave 115 20025044 20516 20530 2080218426

210635761

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 164 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1260 Peak 8 Ave 114 20092729 80982 75320 7482969000

785718832

DCB Decachlorobiphenyl Ave 104 200306013 281530 257456 246481238335

265963086

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 165 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vf479200dLevel 2 IC 460-1299268 vf479201dLevel 3 IC 460-1299269 vf479202dLevel 4 IC 460-12992610 vf479203dLevel 5 IC 460-12992611 vf479204d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1LVL 2 LVL 2LVL 3 LVL 3LVL 4 LVL 4LVL 5 LVL 5

PCB-1016 Peak 1 Ave 1285777 5241842 9647477 14643185 21530533 100 500 1000 1500 2500PCB-1016 Peak 2 Ave 2524804 10590544 20808307 30213965 45462323 100 500 1000 1500 2500PCB-1016 Peak 3 Ave 1035943 4500373 8352607 12661468 18540701 100 500 1000 1500 2500PCB-1016 Peak 4 Ave 4557926 19475271 35290615 53874092 82034010 100 500 1000 1500 2500PCB-1016 Peak 5 Ave 1948484 8838480 14821328 23927783 35848765 100 500 1000 1500 2500PCB-1016 Peak 6 Ave 1240957 5152808 8954270 13558761 20356566 100 500 1000 1500 2500PCB-1016 Peak 7 Ave 1509707 6213265 11165134 16822458 25115800 100 500 1000 1500 2500PCB-1016 Peak 8 Ave 1445572 6260864 11609452 17418946 26330856 100 500 1000 1500 2500PCB-1260 Peak 1 Ave 2816529 11159859 20851674 30895442 46495806 100 500 1000 1500 2500PCB-1260 Peak 2 Ave 3239811 12615093 23518487 34726449 52908911 100 500 1000 1500 2500PCB-1260 Peak 3 Ave 4279245 18792136 35705636 53240044 81893015 100 500 1000 1500 2500PCB-1260 Peak 4 Ave 1912505 8363664 15681452 23213228 35484032 100 500 1000 1500 2500PCB-1260 Peak 5 Ave 974074 4516956 8644462 12914338 20108960 100 500 1000 1500 2500PCB-1260 Peak 6 Ave 2021814 8418625 16386843 24307809 37450674 100 500 1000 1500 2500PCB-1260 Peak 7 Ave 2504445 10257895 20530020 31202581 46064749 100 500 1000 1500 2500PCB-1260 Peak 8 Ave 927285 4049088 7531982 11224374 17250044 100 500 1000 1500 2500DCB Decachlorobiphenyl Ave 7650320 14076513 25745578 36972164 47667099 250 500 100 150 200

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 166 of 323

Data File vf479200d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479200dLab Smp Id IC-SG1660L1_00013 Inj Date 30-SEP-2012 1704 Operator Inst ID PESTGC9iSmp Info ic-SG1660L1_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1704 Cal File vf479200dAls bottle 7 Calibration Sample Level 1Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2960 2961 -0001 1285777 100000 120 8000- 12000 10000

3640 3641 -0001 2524804 100000 120 15709- 23564 19636

4084 4085 -0001 1035943 100000 120 6446- 9668 8057

4477 4479 -0002 4557926 100000 120 28359- 42539 35449

4722 4722 0000 1948484 100000 120 12123- 18185 15154

5157 5158 -0001 1240957 100000 130 7721- 11582 9651

5542 5542 0000 1509707 100000 120 9393- 14090 11742

5751 5752 -0001 1445572 100000 120 8994- 13491 11243

Average of Peak Amounts = 122

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 2816529 100000 130 8000- 12000 10000(M)

10162012Page 167 of 323

Data File vf479200d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8216 8215 0001 3239811 100000 130 9202- 13803 11503

9084 9084 0000 4279245 100000 120 12155- 18232 15193

9332 9332 0000 1912505 100000 120 5432- 8148 6790

9454 9454 0000 974074 100000 110 2767- 4150 3458

9901 9901 0000 2021814 100000 120 5743- 8614 7178

10617 10616 0001 2504445 100000 120 7114- 10670 8892

11087 11086 0001 927285 100000 120 2634- 3951 3292

Average of Peak Amounts = 120

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11518 11515 0003 7650320 250000 29 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 168 of 323

Data File vf479200d

Date 30-SEP-2012 1704

Client ID Instrument PESTGC9i

Sample Info ic-SG1660L1_00013 Operator

10162012Page 169 of 323

Data File vf479201d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479201dLab Smp Id IC-SG1660L2_00013 Inj Date 30-SEP-2012 1720 Operator Inst ID PESTGC9iSmp Info SG1660L2_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1720 Cal File vf479201dAls bottle 8 Calibration Sample Level 2Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2960 2961 -0001 5241842 500000 510 8000- 12000 10000

3640 3641 -0001 10590544 500000 500 16163- 24245 20204

4084 4085 -0001 4500373 500000 520 6868- 10303 8585

4477 4479 -0002 19475271 500000 520 29723- 44584 37153

4722 4722 0000 8838480 500000 540 13489- 20234 16861

5158 5158 0000 5152808 500000 530 7864- 11796 9830

5543 5542 0001 6213265 500000 520 9483- 14224 11853

5751 5752 -0001 6260864 500000 520 9555- 14333 11944

Average of Peak Amounts = 518

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 11159859 500000 500 8000- 12000 10000(M)

10162012Page 170 of 323

Data File vf479201d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 12615093 500000 500 9043- 13565 11304

9084 9084 0000 18792136 500000 510 13471- 20207 16839

9332 9332 0000 8363664 500000 510 5996- 8993 7494

9454 9454 0000 4516956 500000 510 3238- 4857 4048

9901 9901 0000 8418625 500000 500 6035- 9052 7544

10617 10616 0001 10257895 500000 490 7353- 11030 9192

11087 11086 0001 4049088 500000 520 2903- 4354 3628

Average of Peak Amounts = 506

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11520 11515 0005 14076513 500000 53 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 171 of 323

Data File vf479201d

Date 30-SEP-2012 1720

Client ID Instrument PESTGC9i

Sample Info SG1660L2_00013 Operator

10162012Page 172 of 323

Data File vf479202d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479202dLab Smp Id IC-SG1660L3_00019 Inj Date 30-SEP-2012 1735 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 9 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2961 2961 0000 9647477 100000 940 8000- 12000 10000

3641 3641 0000 20808307 100000 980 17255- 25882 21569

4085 4085 0000 8352607 100000 960 6926- 10389 8658

4479 4479 0000 35290615 100000 940 29264- 43896 36580

4722 4722 0000 14821328 100000 900 12290- 18435 15363

5158 5158 0000 8954270 100000 920 7425- 11138 9281

5542 5542 0000 11165134 100000 930 9258- 13888 11573

5752 5752 0000 11609452 100000 960 9627- 14440 12034

Average of Peak Amounts = 940

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 20851674 100000 940 8000- 12000 10000(M)

10162012Page 173 of 323

Data File vf479202d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 23518487 100000 940 9023- 13535 11279

9084 9084 0000 35705636 100000 970 13699- 20548 17124

9332 9332 0000 15681452 100000 960 6016- 9025 7520

9454 9454 0000 8644462 100000 980 3317- 4975 4146

9901 9901 0000 16386843 100000 970 6287- 9431 7859

10616 10616 0000 20530020 100000 970 7877- 11815 9846

11086 11086 0000 7531982 100000 960 2890- 4335 3612

Average of Peak Amounts = 962

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11515 11515 0000 25745578 100000 97 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 174 of 323

Data File vf479202d

Date 30-SEP-2012 1735

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 175 of 323

Data File vf479203d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479203dLab Smp Id IC-SG1660L4_00013 Inj Date 30-SEP-2012 1751 Operator Inst ID PESTGC9iSmp Info SG1660L4_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1751 Cal File vf479203dAls bottle 10 Calibration Sample Level 4Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2959 2961 -0002 14643185 150000 1400 8000- 12000 10000

3639 3641 -0002 30213965 150000 1400 16507- 24760 20633

4083 4085 -0002 12661468 150000 1400 6917- 10376 8647

4477 4479 -0002 53874092 150000 1400 29433- 44149 36791

4722 4722 0000 23927783 150000 1400 13072- 19609 16341

5157 5158 -0001 13558761 150000 1400 7408- 11111 9259

5542 5542 0000 16822458 150000 1400 9191- 13786 11488

5751 5752 -0001 17418946 150000 1400 9516- 14275 11896

Average of Peak Amounts = 143e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 30895442 150000 1400 8000- 12000 10000(M)

10162012Page 176 of 323

Data File vf479203d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 34726449 150000 1400 8992- 13488 11240

9083 9084 -0001 53240044 150000 1400 13786- 20679 17232

9332 9332 0000 23213228 150000 1400 6011- 9016 7513

9454 9454 0000 12914338 150000 1500 3344- 5016 4180

9901 9901 0000 24307809 150000 1400 6294- 9441 7868

10617 10616 0001 31202581 150000 1500 8080- 12119 10099

11084 11086 -0002 11224374 150000 1400 2906- 4360 3633

Average of Peak Amounts = 143e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11510 11515 -0005 36972164 150000 140 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 177 of 323

Data File vf479203d

Date 30-SEP-2012 1751

Client ID Instrument PESTGC9i

Sample Info SG1660L4_00013 Operator

10162012Page 178 of 323

Data File vf479204d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479204dLab Smp Id IC-SG1660L5_00013 Inj Date 30-SEP-2012 1807 Operator Inst ID PESTGC9iSmp Info SG1660L5_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1807 Cal File vf479204dAls bottle 11 Calibration Sample Level 5Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2959 2961 -0002 21530533 250000 2100 8000- 12000 10000

3640 3641 -0001 45462323 250000 2200 16892- 25338 21115

4083 4085 -0002 18540701 250000 2100 6889- 10334 8611

4476 4479 -0003 82034010 250000 2200 30481- 45721 38101

4722 4722 0000 35848765 250000 2200 13320- 19980 16650

5157 5158 -0001 20356566 250000 2100 7564- 11346 9455

5542 5542 0000 25115800 250000 2100 9332- 13998 11665

5751 5752 -0001 26330856 250000 2200 9784- 14675 12230

Average of Peak Amounts = 213e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7755 7756 -0001 46495806 250000 2100 8000- 12000 10000(M)

10162012Page 179 of 323

Data File vf479204d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 52908911 250000 2100 9103- 13655 11379

9082 9084 -0002 81893015 250000 2200 14090- 21136 17613

9331 9332 -0001 35484032 250000 2200 6105- 9158 7632

9453 9454 -0001 20108960 250000 2300 3460- 5190 4325

9901 9901 0000 37450674 250000 2200 6444- 9666 8055

10616 10616 0000 46064749 250000 2200 7926- 11889 9907

11085 11086 -0001 17250044 250000 2200 2968- 4452 3710

Average of Peak Amounts = 219e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11512 11515 -0003 47667099 200000 180 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 180 of 323

Data File vf479204d

Date 30-SEP-2012 1807

Client ID Instrument PESTGC9i

Sample Info SG1660L5_00013 Operator

10162012Page 181 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vr479200dLevel 2 IC 460-1299268 vr479201dLevel 3 IC 460-1299269 vr479202dLevel 4 IC 460-12992610 vr479203dLevel 5 IC 460-12992611 vr479204d

ANALYTE LVL 1 LVL 2 LVL 3 LVL 4 LVL 5 AVG RTRT WINDOW

PCB-1016 Peak 1 20842015 - 21552085 2084 2085 2083 2084PCB-1016 Peak 2 25272457 - 25972527 2526 2527 2527 2526PCB-1016 Peak 3 27762707 - 28472777 2776 2777 2775 2775PCB-1016 Peak 4 31283060 - 32003128 3128 3130 3128 3127PCB-1016 Peak 5 33293260 - 34003329 3329 3330 3328 3328PCB-1016 Peak 6 36823615 - 37553682 3682 3685 3683 3681PCB-1016 Peak 7 40433973 - 41134042 4043 4043 4042 4043PCB-1016 Peak 8 41904121 - 42614190 4190 4191 4188 4190PCB-1260 Peak 1 60716002 - 61426072 6072 6072 6071 6071PCB-1260 Peak 2 65226452 - 65926522 6523 6522 6522 6521PCB-1260 Peak 3 69646894 - 70346964 6965 6964 6963 6964PCB-1260 Peak 4 71647095 - 72357165 7165 7165 7164 7164PCB-1260 Peak 5 76027532 - 76727602 7603 7602 7602 7601PCB-1260 Peak 6 88938823 - 89638893 8894 8893 8893 8892PCB-1260 Peak 7 91159045 - 91859115 9115 9115 9115 9114PCB-1260 Peak 8 1015310083 - 1022310153 10154 10153 10153 10153DCB Decachlorobiphenyl 1062410524 - 1072410625 10625 10624 10624 10624

FORM VI 8082 10162012Page 182 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1299267 vr479200d2Level IC 460-1299268 vr479201d3Level IC 460-1299269 vr479202d4Level IC 460-12992610 vr479203d5Level IC 460-12992611 vr479204d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1016 Peak 1 Ave 197 20021391 15827 14690 1421213626

159493236

PCB-1016 Peak 2 Ave 165 20034434 28377 25503 2514722693

272309984

PCB-1016 Peak 3 Ave 77 20020149 18502 16986 1713716990

179529604

PCB-1016 Peak 4 Ave 163 20075334 61344 55787 5498850020

594947119

PCB-1016 Peak 5 Ave 111 20026774 23733 21963 2197020028

228936643

PCB-1016 Peak 6 Ave 186 20030865 24479 22517 2109919526

236972316

PCB-1016 Peak 7 Ave 97 20025842 23012 21540 2153920131

224127747

PCB-1016 Peak 8 Ave 151 20012619 94689 86303 1057294995

101578271

PCB-1260 Peak 1 Ave 163 20041532 33110 31025 3015327565

326771001

PCB-1260 Peak 2 Ave 177 20078411 60909 57128 5539650491

604671657

PCB-1260 Peak 3 Ave 138 20068452 55082 53236 5187948612

554520757

PCB-1260 Peak 4 Ave 154 20037971 30462 28586 2772626073

301638112

PCB-1260 Peak 5 Ave 148 20034082 26592 25567 2477624302

270637128

PCB-1260 Peak 6 Ave 81 20038982 34673 33173 3331131697

343672090

PCB-1260 Peak 7 Ave 66 20023297 21847 20031 2012320512

211620048

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 183 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1260 Peak 8 Ave 59 20018824 17382 16914 1709216013

172450198

DCB Decachlorobiphenyl Ave 109 200544588 499440 455074 438703415700

470701073

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 184 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vr479200dLevel 2 IC 460-1299268 vr479201dLevel 3 IC 460-1299269 vr479202dLevel 4 IC 460-12992610 vr479203dLevel 5 IC 460-12992611 vr479204d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1LVL 2 LVL 2LVL 3 LVL 3LVL 4 LVL 4LVL 5 LVL 5

PCB-1016 Peak 1 Ave 2139086 7913738 14690255 21317999 34065069 100 500 1000 1500 2500PCB-1016 Peak 2 Ave 3443416 14188692 25503333 37720095 56733462 100 500 1000 1500 2500PCB-1016 Peak 3 Ave 2014938 9251204 16986172 25705034 42475382 100 500 1000 1500 2500PCB-1016 Peak 4 Ave 7533379 30672168 55786970 82482485 125050351 100 500 1000 1500 2500PCB-1016 Peak 5 Ave 2677413 11866731 21962918 32955239 50069130 100 500 1000 1500 2500PCB-1016 Peak 6 Ave 3086462 12239557 22517485 31648230 48815297 100 500 1000 1500 2500PCB-1016 Peak 7 Ave 2584175 11505820 21540272 32309208 50326849 100 500 1000 1500 2500PCB-1016 Peak 8 Ave 1261883 4734436 8630325 15857466 23748661 100 500 1000 1500 2500PCB-1260 Peak 1 Ave 4153239 16554914 31025367 45229464 68912349 100 500 1000 1500 2500PCB-1260 Peak 2 Ave 7841143 30454619 57128111 83094008 126227611 100 500 1000 1500 2500PCB-1260 Peak 3 Ave 6845178 27541094 53235986 77818190 121529078 100 500 1000 1500 2500PCB-1260 Peak 4 Ave 3797116 15230911 28586487 41589423 65183263 100 500 1000 1500 2500PCB-1260 Peak 5 Ave 3408191 13295973 25567248 37163734 60754093 100 500 1000 1500 2500PCB-1260 Peak 6 Ave 3898216 17336408 33172625 49966572 79243490 100 500 1000 1500 2500PCB-1260 Peak 7 Ave 2329661 10923449 20031237 30184937 51279969 100 500 1000 1500 2500PCB-1260 Peak 8 Ave 1882356 8691093 16914378 25637846 40032694 100 500 1000 1500 2500DCB Decachlorobiphenyl Ave 13614701 24972013 45507407 65805444 83140007 250 500 100 150 200

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 185 of 323

Data File vr479200d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479200dLab Smp Id IC-SG1660L1_00013 Inj Date 30-SEP-2012 1704 Operator Inst ID PESTGC9iSmp Info ic-SG1660L1_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 7 Calibration Sample Level 1Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2085 2085 0000 2139086 100000 130 8000- 12000 10000(M)

2527 2527 0000 3443416 100000 130 13324- 19985 16098

2777 2777 0000 2014938 100000 110 9975- 14963 9420

3128 3130 -0002 7533379 100000 130 29367- 44051 35218

3329 3330 -0001 2677413 100000 120 11758- 17638 12517

3682 3685 -0003 3086462 100000 130 11464- 17196 14429

4042 4043 -0001 2584175 100000 120 11819- 17728 12081

4190 4191 -0001 1261883 100000 120 5577- 8366 5899

Average of Peak Amounts = 123

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 4153239 100000 130 8000- 12000 10000

10162012Page 186 of 323

Data File vr479200d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 7841143 100000 130 14654- 21981 18880

6964 6964 0000 6845178 100000 120 14108- 21162 16482

7165 7165 0000 3797116 100000 120 7567- 11351 9143

7602 7602 0000 3408191 100000 120 7053- 10579 8206

8893 8893 0000 3898216 100000 110 9199- 13799 9386

9115 9115 0000 2329661 100000 110 5953- 8930 5609

10153 10153 0000 1882356 100000 110 4647- 6971 4532

Average of Peak Amounts = 121

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10625 10624 0001 13614701 250000 29 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 187 of 323

Data File vr479200d

Date 30-SEP-2012 1704

Client ID Instrument PESTGC9i

Sample Info ic-SG1660L1_00013 Operator

10162012Page 188 of 323

Data File vr479201d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479201dLab Smp Id IC-SG1660L2_00013 Inj Date 30-SEP-2012 1720 Operator Inst ID PESTGC9iSmp Info SG1660L2_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 8 Calibration Sample Level 2Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2084 2085 -0001 7913738 500000 500 8000- 12000 10000(M)

2526 2527 -0001 14188692 500000 520 13324- 19985 17929

2776 2777 -0001 9251204 500000 520 9975- 14963 11690

3128 3130 -0002 30672168 500000 520 29367- 44051 38758

3329 3330 -0001 11866731 500000 520 11758- 17638 14995

3682 3685 -0003 12239557 500000 520 11464- 17196 15466

4043 4043 0000 11505820 500000 510 11819- 17728 14539

4190 4191 -0001 4734436 500000 470 5577- 8366 5983

Average of Peak Amounts = 508

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 16554914 500000 510 8000- 12000 10000

10162012Page 189 of 323

Data File vr479201d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6523 6522 0001 30454619 500000 500 14654- 21981 18396

6965 6964 0001 27541094 500000 500 14108- 21162 16636

7165 7165 0000 15230911 500000 500 7567- 11351 9200

7603 7602 0001 13295973 500000 490 7053- 10579 8031

8894 8893 0001 17336408 500000 500 9199- 13799 10472

9115 9115 0000 10923449 500000 520 5953- 8930 6598

10154 10153 0001 8691093 500000 500 4647- 6971 5250

Average of Peak Amounts = 503

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10625 10624 0001 24972013 500000 53 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 190 of 323

Data File vr479201d

Date 30-SEP-2012 1720

Client ID Instrument PESTGC9i

Sample Info SG1660L2_00013 Operator

10162012Page 191 of 323

Data File vr479202d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479202dLab Smp Id IC-SG1660L3_00019 Inj Date 30-SEP-2012 1735 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 9 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2085 2085 0000 14690255 100000 920 8000- 12000 10000(M)

2527 2527 0000 25503333 100000 940 13324- 19985 17361

2777 2777 0000 16986172 100000 950 9975- 14963 11563

3130 3130 0000 55786970 100000 940 29367- 44051 37975

3330 3330 0000 21962918 100000 960 11758- 17638 14951

3685 3685 0000 22517485 100000 950 11464- 17196 15328

4043 4043 0000 21540272 100000 960 11819- 17728 14663

4191 4191 0000 8630325 100000 850 5577- 8366 5875

Average of Peak Amounts = 933

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 31025367 100000 950 8000- 12000 10000

10162012Page 192 of 323

Data File vr479202d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 57128111 100000 940 14654- 21981 18413

6964 6964 0000 53235986 100000 960 14108- 21162 17159

7165 7165 0000 28586487 100000 950 7567- 11351 9214

7602 7602 0000 25567248 100000 940 7053- 10579 8241

8893 8893 0000 33172625 100000 960 9199- 13799 10692

9115 9115 0000 20031237 100000 950 5953- 8930 6456

10153 10153 0000 16914378 100000 980 4647- 6971 5452

Average of Peak Amounts = 955

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 45507407 100000 97 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 193 of 323

Data File vr479202d

Date 30-SEP-2012 1735

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 194 of 323

Data File vr479203d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479203dLab Smp Id IC-SG1660L4_00013 Inj Date 30-SEP-2012 1751 Operator Inst ID PESTGC9iSmp Info SG1660L4_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 10 Calibration Sample Level 4Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2083 2085 -0002 21317999 150000 1300 8000- 12000 10000(M)

2527 2527 0000 37720095 150000 1400 13324- 19985 17694

2775 2777 -0002 25705034 150000 1400 9975- 14963 12058

3128 3130 -0002 82482485 150000 1400 29367- 44051 38691

3328 3330 -0002 32955239 150000 1400 11758- 17638 15459

3683 3685 -0002 31648230 150000 1300 11464- 17196 14846

4042 4043 -0001 32309208 150000 1400 11819- 17728 15156

4188 4191 -0003 15857466 150000 1600 5577- 8366 7439

Average of Peak Amounts = 141e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6071 6072 -0001 45229464 150000 1400 8000- 12000 10000

10162012Page 195 of 323

Data File vr479203d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 83094008 150000 1400 14654- 21981 18372

6963 6964 -0001 77818190 150000 1400 14108- 21162 17205

7164 7165 -0001 41589423 150000 1400 7567- 11351 9195

7602 7602 0000 37163734 150000 1400 7053- 10579 8217

8893 8893 0000 49966572 150000 1400 9199- 13799 11047

9115 9115 0000 30184937 150000 1400 5953- 8930 6674

10153 10153 0000 25637846 150000 1500 4647- 6971 5668

Average of Peak Amounts = 141e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 65805444 150000 140 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 196 of 323

Data File vr479203d

Date 30-SEP-2012 1751

Client ID Instrument PESTGC9i

Sample Info SG1660L4_00013 Operator

10162012Page 197 of 323

Data File vr479204d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479204dLab Smp Id IC-SG1660L5_00013 Inj Date 30-SEP-2012 1807 Operator Inst ID PESTGC9iSmp Info SG1660L5_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 11 Calibration Sample Level 5Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2084 2085 -0001 34065069 250000 2100 8000- 12000 10000(M)

2526 2527 -0001 56733462 250000 2100 13324- 19985 16654

2775 2777 -0002 42475382 250000 2400 9975- 14963 12469

3127 3130 -0003 125050351 250000 2100 29367- 44051 36709

3328 3330 -0002 50069130 250000 2200 11758- 17638 14698

3681 3685 -0004 48815297 250000 2000 11464- 17196 14330

4043 4043 0000 50326849 250000 2200 11819- 17728 14774

4190 4191 -0001 23748661 250000 2300 5577- 8366 6972

Average of Peak Amounts = 219e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6071 6072 -0001 68912349 250000 2100 8000- 12000 10000

10162012Page 198 of 323

Data File vr479204d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6521 6522 -0001 126227611 250000 2100 14654- 21981 18317

6964 6964 0000 121529078 250000 2200 14108- 21162 17635

7164 7165 -0001 65183263 250000 2200 7567- 11351 9459

7601 7602 -0001 60754093 250000 2200 7053- 10579 8816

8892 8893 -0001 79243490 250000 2300 9199- 13799 11499

9114 9115 -0001 51279969 250000 2400 5953- 8930 7441

10153 10153 0000 40032694 250000 2300 4647- 6971 5809

Average of Peak Amounts = 223e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 83140007 200000 180 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 199 of 323

Data File vr479204d

Date 30-SEP-2012 1807

Client ID Instrument PESTGC9i

Sample Info SG1660L5_00013 Operator

10162012Page 200 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vf479205d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1221 Peak 1 16651595 - 17351665PCB-1221 Peak 2 21352065 - 22052135PCB-1221 Peak 3 26722602 - 27422672PCB-1221 Peak 4 28732803 - 29432873PCB-1221 Peak 5 29612891 - 30312961PCB-1221 Peak 6 37393669 - 38093739PCB-1221 Peak 7 40834013 - 41534083PCB-1221 Peak 8 44774407 - 45474477

FORM VI 8082 10162012Page 201 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992612 vf479205d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

47106PCB-1221 Peak 1 Ave 20047106130012961PCB-1221 Peak 2 Ave 20012960750058524PCB-1221 Peak 3 Ave 20058523710040015PCB-1221 Peak 4 Ave 20040015420013789PCB-1221 Peak 5 Ave 20013788908018488PCB-1221 Peak 6 Ave 20018488040061501PCB-1221 Peak 7 Ave 20061500800024165PCB-1221 Peak 8 Ave 200241652800

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 202 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vf479205d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1221 Peak 1 Ave 4710613 1000PCB-1221 Peak 2 Ave 1296075 1000PCB-1221 Peak 3 Ave 5852371 1000PCB-1221 Peak 4 Ave 4001542 1000PCB-1221 Peak 5 Ave 13788908 1000PCB-1221 Peak 6 Ave 1848804 1000PCB-1221 Peak 7 Ave 615008 1000PCB-1221 Peak 8 Ave 2416528 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 203 of 323

Data File vf479205d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479205dLab Smp Id IC-SG1221L3_00014 Inj Date 30-SEP-2012 1822 Operator Inst ID PESTGC9iSmp Info ic SG1221L3_00014Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 12 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12210subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

22 Aroclor-1221 CAS 11104-28-2

1665 1665 0000 4710613 100000 1000 8000- 12000 10000

2135 2135 0000 1296075 100000 1000 2201- 3302 2751

2672 2672 0000 5852371 100000 1000 9939- 14909 12424

2873 2873 0000 4001542 100000 1000 6796- 10194 8495

2961 2961 0000 13788908 100000 1000 23418- 35126 29272

3739 3739 0000 1848804 100000 1000 3140- 4710 3925

4083 4083 0000 615008 100000 1000 1044- 1567 1306

4477 4477 0000 2416528 100000 1000 4104- 6156 5130

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 204 of 323

Data File vf479205d

Date 30-SEP-2012 1822

Client ID Instrument PESTGC9i

Sample Info ic SG1221L3_00014 Operator

10162012Page 205 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vr479205d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1221 Peak 1 11111041 - 11811111PCB-1221 Peak 2 15111441 - 15811511PCB-1221 Peak 3 18601790 - 19301860PCB-1221 Peak 4 20822012 - 21522082PCB-1221 Peak 5 25282458 - 25982528PCB-1221 Peak 6 26022532 - 26722602PCB-1221 Peak 7 26852615 - 27552685PCB-1221 Peak 8 31303060 - 32003130

FORM VI 8082 10162012Page 206 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992612 vr479205d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

64024PCB-1221 Peak 1 Ave 20064024020030571PCB-1221 Peak 2 Ave 20030571000095270PCB-1221 Peak 3 Ave 20095269770024981PCB-1221 Peak 4 Ave 20024981158027336PCB-1221 Peak 5 Ave 20027336400022123PCB-1221 Peak 6 Ave 20022122590041633PCB-1221 Peak 7 Ave 20041632790048909PCB-1221 Peak 8 Ave 200489094700

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 207 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vr479205d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1221 Peak 1 Ave 6402402 1000PCB-1221 Peak 2 Ave 3057100 1000PCB-1221 Peak 3 Ave 9526977 1000PCB-1221 Peak 4 Ave 24981158 1000PCB-1221 Peak 5 Ave 2733640 1000PCB-1221 Peak 6 Ave 2212259 1000PCB-1221 Peak 7 Ave 4163279 1000PCB-1221 Peak 8 Ave 4890947 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 208 of 323

Data File vr479205d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479205dLab Smp Id IC-SG1221L3_00014 Inj Date 30-SEP-2012 1822 Operator Inst ID PESTGC9iSmp Info ic SG1221L3_00014Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 12 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12210subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

22 Aroclor-1221 CAS 11104-28-2

1111 1111 0000 6402402 100000 1000 8000- 12000 10000(M)

1511 1511 0000 3057100 100000 1000 3820- 5730 4775

1860 1860 0000 9526977 100000 1000 11904- 17856 14880

2082 2082 0000 24981158 100000 1000 31215- 46822 39018

2528 2528 0000 2733640 100000 1000 3416- 5124 4270

2602 2602 0000 2212259 100000 1000 2764- 4146 3455

2685 2685 0000 4163279 100000 1000 5202- 7803 6503

3130 3130 0000 4890947 100000 1000 6111- 9167 7639

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 209 of 323

Data File vr479205d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 210 of 323

Data File vr479205d

Date 30-SEP-2012 1822

Client ID Instrument PESTGC9i

Sample Info ic SG1221L3_00014 Operator

10162012Page 211 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vf479206d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1232 Peak 1 29612891 - 30312961PCB-1232 Peak 2 36403570 - 37103640PCB-1232 Peak 3 40854015 - 41554085PCB-1232 Peak 4 47224652 - 47924722PCB-1232 Peak 5 49024832 - 49724902PCB-1232 Peak 6 50875017 - 51575087PCB-1232 Peak 7 55425472 - 56125542PCB-1232 Peak 8 57515681 - 58215751

FORM VI 8082 10162012Page 212 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992613 vf479206d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

97711PCB-1232 Peak 1 Ave 20097710620094688PCB-1232 Peak 2 Ave 20094688030035761PCB-1232 Peak 3 Ave 20035761260066995PCB-1232 Peak 4 Ave 20066994820050607PCB-1232 Peak 5 Ave 20050607280041053PCB-1232 Peak 6 Ave 20041053380057396PCB-1232 Peak 7 Ave 20057395890062677PCB-1232 Peak 8 Ave 200626765000

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 213 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vf479206d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1232 Peak 1 Ave 9771062 1000PCB-1232 Peak 2 Ave 9468803 1000PCB-1232 Peak 3 Ave 3576126 1000PCB-1232 Peak 4 Ave 6699482 1000PCB-1232 Peak 5 Ave 5060728 1000PCB-1232 Peak 6 Ave 4105338 1000PCB-1232 Peak 7 Ave 5739589 1000PCB-1232 Peak 8 Ave 6267650 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 214 of 323

Data File vf479206d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479206dLab Smp Id ic SG1232L3_00013 Inj Date 30-SEP-2012 1838 Operator Inst ID PESTGC9iSmp Info ic SG1232L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 13 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12320subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

23 Aroclor-1232 CAS 11141-16-5

2961 2961 0000 9771062 100000 1000 8000- 12000 10000

3640 3640 0000 9468803 100000 1000 7753- 11629 9691

4085 4085 0000 3576126 100000 1000 2928- 4392 3660

4722 4722 0000 6699482 100000 1000 5485- 8228 6856

4902 4902 0000 5060728 100000 1000 4143- 6215 5179

5087 5087 0000 4105338 100000 1000 3361- 5042 4202

5542 5542 0000 5739589 100000 1000 4699- 7049 5874

5751 5751 0000 6267650 100000 1000 5132- 7697 6415

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 215 of 323

Data File vf479206d

Date 30-SEP-2012 1838

Client ID Instrument PESTGC9i

Sample Info ic SG1232L3_00013 Operator

10162012Page 216 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vr479206d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1232 Peak 1 20822012 - 21522082PCB-1232 Peak 2 25262456 - 25962526PCB-1232 Peak 3 27762706 - 28462776PCB-1232 Peak 4 31283058 - 31983128PCB-1232 Peak 5 33293259 - 33993329PCB-1232 Peak 6 34243354 - 34943424PCB-1232 Peak 7 40423972 - 41124042PCB-1232 Peak 8 46144544 - 46844614

FORM VI 8082 10162012Page 217 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992613 vr479206d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

18402PCB-1232 Peak 1 Ave 20018402354014182PCB-1232 Peak 2 Ave 20014181613010089PCB-1232 Peak 3 Ave 20010089309027669PCB-1232 Peak 4 Ave 20027669356010841PCB-1232 Peak 5 Ave 20010840936085833PCB-1232 Peak 6 Ave 20085833230011581PCB-1232 Peak 7 Ave 20011580551048393PCB-1232 Peak 8 Ave 200483934800

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 218 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vr479206d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1232 Peak 1 Ave 18402354 1000PCB-1232 Peak 2 Ave 14181613 1000PCB-1232 Peak 3 Ave 10089309 1000PCB-1232 Peak 4 Ave 27669356 1000PCB-1232 Peak 5 Ave 10840936 1000PCB-1232 Peak 6 Ave 8583323 1000PCB-1232 Peak 7 Ave 11580551 1000PCB-1232 Peak 8 Ave 4839348 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 219 of 323

Data File vr479206d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479206dLab Smp Id ic SG1232L3_00013 Inj Date 30-SEP-2012 1838 Operator Inst ID PESTGC9iSmp Info ic SG1232L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 13 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12320subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

23 Aroclor-1232 CAS 11141-16-5

2082 2082 0000 18402354 100000 1000 8000- 12000 10000

2526 2526 0000 14181613 100000 1000 6165- 9248 7706

2776 2776 0000 10089309 100000 1000 4386- 6579 5483

3128 3128 0000 27669356 100000 1000 12029- 18043 15036

3329 3329 0000 10840936 100000 1000 4713- 7069 5891

3424 3424 0000 8583323 100000 1000 3731- 5597 4664

4042 4042 0000 11580551 100000 1000 5034- 7552 6293

4614 4614 0000 4839348 100000 1000 2104- 3156 2630

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 220 of 323

Data File vr479206d

Date 30-SEP-2012 1838

Client ID Instrument PESTGC9i

Sample Info ic SG1232L3_00013 Operator

10162012Page 221 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vf479207d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1242 Peak 1 29612891 - 30312961PCB-1242 Peak 2 36413571 - 37113641PCB-1242 Peak 3 40864016 - 41564086PCB-1242 Peak 4 44794409 - 45494479PCB-1242 Peak 5 47234653 - 47934723PCB-1242 Peak 6 51585088 - 52285158PCB-1242 Peak 7 57525682 - 58225752PCB-1242 Peak 8 62656195 - 63356265

FORM VI 8082 10162012Page 222 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992614 vf479207d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

81414PCB-1242 Peak 1 Ave 20081414290015365PCB-1242 Peak 2 Ave 20015365311065982PCB-1242 Peak 3 Ave 20065981950028106PCB-1242 Peak 4 Ave 20028106459012209PCB-1242 Peak 5 Ave 20012208628069961PCB-1242 Peak 6 Ave 20069960990010615PCB-1242 Peak 7 Ave 20010615499010283PCB-1242 Peak 8 Ave 200102828980

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 223 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vf479207d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1242 Peak 1 Ave 8141429 1000PCB-1242 Peak 2 Ave 15365311 1000PCB-1242 Peak 3 Ave 6598195 1000PCB-1242 Peak 4 Ave 28106459 1000PCB-1242 Peak 5 Ave 12208628 1000PCB-1242 Peak 6 Ave 6996099 1000PCB-1242 Peak 7 Ave 10615499 1000PCB-1242 Peak 8 Ave 10282898 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 224 of 323

Data File vf479207d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479207dLab Smp Id ic SG1242L3_00013 Inj Date 30-SEP-2012 1854 Operator Inst ID PESTGC9iSmp Info ic SG1242L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 14 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12420subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

24 Aroclor-1242 CAS 53469-21-9

2961 2961 0000 8141429 100000 1000 8000- 12000 10000(M)

3641 3641 0000 15365311 100000 1000 15098- 22648 18873

4086 4086 0000 6598195 100000 1000 6484- 9725 8104

4479 4479 0000 28106459 100000 1000 27618- 41427 34523

4723 4723 0000 12208628 100000 1000 11997- 17995 14996

5158 5158 0000 6996099 100000 1000 6875- 10312 8593

5752 5752 0000 10615499 100000 1000 10431- 15647 13039

6265 6265 0000 10282898 100000 1000 10104- 15156 12630

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 225 of 323

Data File vf479207d Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 226 of 323

Data File vf479207d

Date 30-SEP-2012 1854

Client ID Instrument PESTGC9i

Sample Info ic SG1242L3_00013 Operator

10162012Page 227 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vr479207d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1242 Peak 1 20832013 - 21532083PCB-1242 Peak 2 25272457 - 25972527PCB-1242 Peak 3 27772707 - 28472777PCB-1242 Peak 4 31293059 - 31993129PCB-1242 Peak 5 33293259 - 33993329PCB-1242 Peak 6 36853615 - 37553685PCB-1242 Peak 7 40443974 - 41144044PCB-1242 Peak 8 51265056 - 51965126

FORM VI 8082 10162012Page 228 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992614 vr479207d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

13527PCB-1242 Peak 1 Ave 20013526845020219PCB-1242 Peak 2 Ave 20020218998014340PCB-1242 Peak 3 Ave 20014339987044262PCB-1242 Peak 4 Ave 20044261735017388PCB-1242 Peak 5 Ave 20017387684018314PCB-1242 Peak 6 Ave 20018314121017750PCB-1242 Peak 7 Ave 20017749733015393PCB-1242 Peak 8 Ave 200153932670

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 229 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vr479207d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1242 Peak 1 Ave 13526845 1000PCB-1242 Peak 2 Ave 20218998 1000PCB-1242 Peak 3 Ave 14339987 1000PCB-1242 Peak 4 Ave 44261735 1000PCB-1242 Peak 5 Ave 17387684 1000PCB-1242 Peak 6 Ave 18314121 1000PCB-1242 Peak 7 Ave 17749733 1000PCB-1242 Peak 8 Ave 15393267 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 230 of 323

Data File vr479207d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479207dLab Smp Id ic SG1242L3_00013 Inj Date 30-SEP-2012 1854 Operator Inst ID PESTGC9iSmp Info ic SG1242L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 14 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12420subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

24 Aroclor-1242 CAS 53469-21-9

2083 2083 0000 13526845 100000 1000 8000- 12000 10000(M)

2527 2527 0000 20218998 100000 1000 11958- 17937 14947

2777 2777 0000 14339987 100000 1000 8481- 12721 10601

3129 3129 0000 44261735 100000 1000 26177- 39266 32721

3329 3329 0000 17387684 100000 1000 10283- 15425 12854

3685 3685 0000 18314121 100000 1000 10831- 16247 13539

4044 4044 0000 17749733 100000 1000 10497- 15746 13122

5126 5126 0000 15393267 100000 1000 9104- 13656 11380

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 231 of 323

Data File vr479207d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 232 of 323

Data File vr479207d

Date 30-SEP-2012 1854

Client ID Instrument PESTGC9i

Sample Info ic SG1242L3_00013 Operator

10162012Page 233 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vf479208d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1248 Peak 1 36373567 - 37073637PCB-1248 Peak 2 44734403 - 45434473PCB-1248 Peak 3 49514881 - 50214951PCB-1248 Peak 4 50865016 - 51565086PCB-1248 Peak 5 55415471 - 56115541PCB-1248 Peak 6 57505680 - 58205750PCB-1248 Peak 7 61916121 - 62616191PCB-1248 Peak 8 62626192 - 63326262

FORM VI 8082 10162012Page 234 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992615 vf479208d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

89356PCB-1248 Peak 1 Ave 20089355610020760PCB-1248 Peak 2 Ave 20020759623031559PCB-1248 Peak 3 Ave 20031559070012341PCB-1248 Peak 4 Ave 20012341389015809PCB-1248 Peak 5 Ave 20015808884017466PCB-1248 Peak 6 Ave 20017465791016624PCB-1248 Peak 7 Ave 20016623508019431PCB-1248 Peak 8 Ave 200194311040

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 235 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vf479208d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1248 Peak 1 Ave 8935561 1000PCB-1248 Peak 2 Ave 20759623 1000PCB-1248 Peak 3 Ave 3155907 1000PCB-1248 Peak 4 Ave 12341389 1000PCB-1248 Peak 5 Ave 15808884 1000PCB-1248 Peak 6 Ave 17465791 1000PCB-1248 Peak 7 Ave 16623508 1000PCB-1248 Peak 8 Ave 19431104 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 236 of 323

Data File vf479208d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479208dLab Smp Id ic SG1248L3_00013 Inj Date 30-SEP-2012 1909 Operator Inst ID PESTGC9iSmp Info ic SG1248L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 15 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12480subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

25 Aroclor-1248 CAS 12672-29-6

3637 3637 0000 8935561 100000 1000 8000- 12000 10000

4473 4473 0000 20759623 100000 1000 18586- 27879 23233

4951 4951 0000 3155907 100000 1000 2825- 4238 3532

5086 5086 0000 12341389 100000 1000 11049- 16574 13812

5541 5541 0000 15808884 100000 1000 14154- 21231 17692

5750 5750 0000 17465791 100000 1000 15637- 23456 19546

6191 6191 0000 16623508 100000 1000 14883- 22325 18604

6262 6262 0000 19431104 100000 1000 17397- 26095 21746

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 237 of 323

Data File vf479208d

Date 30-SEP-2012 1909

Client ID Instrument PESTGC9i

Sample Info ic SG1248L3_00013 Operator

10162012Page 238 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vr479208d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1248 Peak 1 25252455 - 25952525PCB-1248 Peak 2 31243054 - 31943124PCB-1248 Peak 3 34233353 - 34933423PCB-1248 Peak 4 36783608 - 37483678PCB-1248 Peak 5 40413971 - 41114041PCB-1248 Peak 6 41864116 - 42564186PCB-1248 Peak 7 46154545 - 46854615PCB-1248 Peak 8 51245054 - 51945124

FORM VI 8082 10162012Page 239 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992615 vr479208d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

11417PCB-1248 Peak 1 Ave 20011416682034274PCB-1248 Peak 2 Ave 20034273988063635PCB-1248 Peak 3 Ave 20063635020034030PCB-1248 Peak 4 Ave 20034030097030220PCB-1248 Peak 5 Ave 20030220358018203PCB-1248 Peak 6 Ave 20018202681015611PCB-1248 Peak 7 Ave 20015610993034370PCB-1248 Peak 8 Ave 200343696460

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 240 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vr479208d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1248 Peak 1 Ave 11416682 1000PCB-1248 Peak 2 Ave 34273988 1000PCB-1248 Peak 3 Ave 6363502 1000PCB-1248 Peak 4 Ave 34030097 1000PCB-1248 Peak 5 Ave 30220358 1000PCB-1248 Peak 6 Ave 18202681 1000PCB-1248 Peak 7 Ave 15610993 1000PCB-1248 Peak 8 Ave 34369646 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 241 of 323

Data File vr479208d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479208dLab Smp Id ic SG1248L3_00013 Inj Date 30-SEP-2012 1909 Operator Inst ID PESTGC9iSmp Info ic SG1248L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 15 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12480subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

25 Aroclor-1248 CAS 12672-29-6

2525 2525 0000 11416682 100000 1000 8000- 12000 10000(M)

3124 3124 0000 34273988 100000 1000 24017- 36025 30021

3423 3423 0000 6363502 100000 1000 4459- 6689 5574

3678 3678 0000 34030097 100000 1000 23846- 35769 29807

4041 4041 0000 30220358 100000 1000 21176- 31764 26470

4186 4186 0000 18202681 100000 1000 12755- 19133 15944

4615 4615 0000 15610993 100000 1000 10939- 16409 13674

5124 5124 0000 34369646 100000 1000 24084- 36126 30105

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 242 of 323

Data File vr479208d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 243 of 323

Data File vr479208d

Date 30-SEP-2012 1909

Client ID Instrument PESTGC9i

Sample Info ic SG1248L3_00013 Operator

10162012Page 244 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vf479209d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1254 Peak 1 50855015 - 51555085PCB-1254 Peak 2 62536183 - 63236253PCB-1254 Peak 3 65806510 - 66506580PCB-1254 Peak 4 71577087 - 72277157PCB-1254 Peak 5 73717301 - 74417371PCB-1254 Peak 6 85968526 - 86668596PCB-1254 Peak 7 90869016 - 91569086PCB-1254 Peak 8 98439773 - 99139843

FORM VI 8082 10162012Page 245 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992616 vf479209d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

97124PCB-1254 Peak 1 Ave 20097124230016374PCB-1254 Peak 2 Ave 20016373834017590PCB-1254 Peak 3 Ave 20017589776013684PCB-1254 Peak 4 Ave 20013683949027505PCB-1254 Peak 5 Ave 20027504947017262PCB-1254 Peak 6 Ave 20017261880028714PCB-1254 Peak 7 Ave 20028713900074774PCB-1254 Peak 8 Ave 200747739500

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 246 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vf479209d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1254 Peak 1 Ave 9712423 1000PCB-1254 Peak 2 Ave 16373834 1000PCB-1254 Peak 3 Ave 17589776 1000PCB-1254 Peak 4 Ave 13683949 1000PCB-1254 Peak 5 Ave 27504947 1000PCB-1254 Peak 6 Ave 17261880 1000PCB-1254 Peak 7 Ave 28713900 1000PCB-1254 Peak 8 Ave 7477395 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 247 of 323

Data File vf479209d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479209dLab Smp Id ic SG1254L3_00013 Inj Date 30-SEP-2012 1925 Operator Inst ID PESTGC9iSmp Info ic SG1254L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 16 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12540subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

26 Aroclor-1254 CAS 11097-69-1

5085 5085 0000 9712423 100000 1000 8000- 12000 10000

6253 6253 0000 16373834 100000 1000 13487- 20230 16859

6580 6580 0000 17589776 100000 1000 14488- 21733 18111

7157 7157 0000 13683949 100000 1000 11271- 16907 14089

7371 7371 0000 27504947 100000 1000 22655- 33983 28319

8596 8596 0000 17261880 100000 1000 14218- 21328 17773

9086 9086 0000 28713900 100000 1000 23651- 35477 29564

9843 9843 0000 7477395 100000 1000 6159- 9239 7699

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 248 of 323

Data File vf479209d

Date 30-SEP-2012 1925

Client ID Instrument PESTGC9i

Sample Info ic SG1254L3_00013 Operator

10162012Page 249 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vr479209d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1254 Peak 1 46874617 - 47574687PCB-1254 Peak 2 47624692 - 48324762PCB-1254 Peak 3 51285058 - 51985128PCB-1254 Peak 4 55695499 - 56395569PCB-1254 Peak 5 57705700 - 58405770PCB-1254 Peak 6 62216151 - 62916221PCB-1254 Peak 7 65216451 - 65916521PCB-1254 Peak 8 69656895 - 70356965

FORM VI 8082 10162012Page 250 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992616 vr479209d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

24886PCB-1254 Peak 1 Ave 20024885981024126PCB-1254 Peak 2 Ave 20024125717033197PCB-1254 Peak 3 Ave 20033196979024470PCB-1254 Peak 4 Ave 20024470162043009PCB-1254 Peak 5 Ave 20043008616038112PCB-1254 Peak 6 Ave 20038111884031186PCB-1254 Peak 7 Ave 20031186488041987PCB-1254 Peak 8 Ave 200419870070

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 251 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vr479209d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1254 Peak 1 Ave 24885981 1000PCB-1254 Peak 2 Ave 24125717 1000PCB-1254 Peak 3 Ave 33196979 1000PCB-1254 Peak 4 Ave 24470162 1000PCB-1254 Peak 5 Ave 43008616 1000PCB-1254 Peak 6 Ave 38111884 1000PCB-1254 Peak 7 Ave 31186488 1000PCB-1254 Peak 8 Ave 41987007 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 252 of 323

Data File vr479209d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479209dLab Smp Id ic SG1254L3_00013 Inj Date 30-SEP-2012 1925 Operator Inst ID PESTGC9iSmp Info ic SG1254L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 16 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12540subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

26 Aroclor-1254 CAS 11097-69-1

4687 4687 0000 24885981 100000 1000 8000- 12000 10000(M)

4762 4762 0000 24125717 100000 1000 7756- 11633 9695

5128 5128 0000 33196979 100000 1000 10672- 16008 13340

5569 5569 0000 24470162 100000 1000 7866- 11799 9833

5770 5770 0000 43008616 100000 1000 13826- 20739 17282

6221 6221 0000 38111884 100000 1000 12252- 18378 15315

6521 6521 0000 31186488 100000 1000 10025- 15038 12532

6965 6965 0000 41987007 100000 1000 13497- 20246 16872

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 253 of 323

Data File vr479209d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 254 of 323

Data File vr479209d

Date 30-SEP-2012 1925

Client ID Instrument PESTGC9i

Sample Info ic SG1254L3_00013 Operator

10162012Page 255 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-2

TestAmerica Edison

Lab File ID vf479493d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1005610273 979 1000 -21 150Ave

PCB-1016 Peak 2 2214321113 1050 1000 49 150Ave

PCB-1016 Peak 3 96058714 1100 1000 102 150Ave

PCB-1016 Peak 4 4004137710 1060 1000 62 150Ave

PCB-1016 Peak 5 1906116455 1160 1000 158 150Ave

PCB-1016 Peak 6 104069770 1070 1000 65 150Ave

PCB-1016 Peak 7 1271211990 1060 1000 60 150Ave

PCB-1016 Peak 8 1381712146 1140 1000 138 150Ave

PCB-1260 Peak 1 2403322106 1090 1000 87 150Ave

PCB-1260 Peak 2 2694125092 1070 1000 74 150Ave

PCB-1260 Peak 3 4112136867 1120 1000 115 150Ave

PCB-1260 Peak 4 1829116241 1130 1000 126 150Ave

PCB-1260 Peak 5 102408814 1160 1000 162 150Ave

PCB-1260 Peak 6 1863416926 1100 1000 101 150Ave

PCB-1260 Peak 7 2108721064 1000 1000 01 150Ave

PCB-1260 Peak 8 80147857 1020 1000 20 150Ave

DCB Decachlorobiphenyl 267686265963 101 100 06 150Ave

FORM VII 8082

10162012Page 256 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-2

TestAmerica Edison

Lab File ID vf479493d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 292 289 303

PCB-1016 Peak 2 359 357 371

PCB-1016 Peak 3 404 401 415

PCB-1016 Peak 4 443 441 455

PCB-1016 Peak 5 468 465 479

PCB-1016 Peak 6 511 509 523

PCB-1016 Peak 7 550 547 561

PCB-1016 Peak 8 571 568 582

PCB-1260 Peak 1 771 769 783

PCB-1260 Peak 2 816 814 828

PCB-1260 Peak 3 902 901 915

PCB-1260 Peak 4 928 926 940

PCB-1260 Peak 5 940 938 952

PCB-1260 Peak 6 986 983 997

PCB-1260 Peak 7 1059 1055 1069

PCB-1260 Peak 8 1106 1102 1116

DCB Decachlorobiphenyl 1149 1141 1161

Form VII 8082

10162012Page 257 of 323

Data File vf479493d Report Date 09-Oct-2012 0318

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479493dLab Smp Id ccvrtsg1660l3_00019 Inj Date 08-OCT-2012 1830 Operator Inst ID PESTGC9iSmp Info ccvrt-sg1660l3_00019Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 21 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2923 2961 -0038 10055641 978875 650 8000- 12000 10000(M)

3593 3641 -0048 22143043 104879 700 16892- 25338 22021

4036 4085 -0049 9604932 110224 730 6889- 10334 9552

4432 4479 -0047 40041013 106181 710 30481- 45721 39819

4678 4722 -0044 19061275 115840 770 13320- 19980 18956

5114 5158 -0044 10405886 106506 710 7564- 11346 10348

5500 5542 -0042 12711848 106020 710 9332- 13998 12642

5709 5752 -0043 13817418 113758 760 9784- 14675 13741

Average of Peak Concentrations = 720

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7706 7756 -0050 24033075 108715 720 8000- 12000 10000(M)

10162012Page 258 of 323

Data File vf479493d Report Date 09-Oct-2012 0318

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8161 8215 -0054 26941342 107369 720 9103- 13655 11210

9020 9084 -0064 41121424 111541 740 14090- 21136 17110

9276 9332 -0056 18291174 112626 750 6105- 9158 7611

9401 9454 -0053 10239798 116171 770 3460- 5190 4261

9861 9901 -0040 18634445 110097 730 6444- 9666 7754

10594 10616 -0022 21087197 100112 670 7926- 11889 12194

11063 11086 -0023 8014273 101999 680 2968- 4452 3335

Average of Peak Concentrations = 720

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11488 11515 -0027 26768608 100648 67 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 259 of 323

Data File vf479493d

Date 08-OCT-2012 1830

Client ID Instrument PESTGC9i

Sample Info ccvrt-sg1660l3_00019 Operator

10162012Page 260 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-1

TestAmerica Edison

Lab File ID vr479493d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1317915949 826 1000 -174 150Ave

PCB-1016 Peak 2 2492127231 915 1000 -85 150Ave

PCB-1016 Peak 3 1751817953 976 1000 -24 150Ave

PCB-1016 Peak 4 5583559495 938 1000 -62 150Ave

PCB-1016 Peak 5 2224122894 971 1000 -29 150Ave

PCB-1016 Peak 6 2383923697 1010 1000 06 150Ave

PCB-1016 Peak 7 2233922413 997 1000 -03 150Ave

PCB-1016 Peak 8 1103010158 1090 1000 86 150Ave

PCB-1260 Peak 1 3241432677 992 1000 -08 150Ave

PCB-1260 Peak 2 6068660467 1000 1000 04 150Ave

PCB-1260 Peak 3 5752255452 1040 1000 37 150Ave

PCB-1260 Peak 4 2973730164 986 1000 -14 150Ave

PCB-1260 Peak 5 2720927064 1010 1000 05 150Ave

PCB-1260 Peak 6 3391634367 987 1000 -13 150Ave

PCB-1260 Peak 7 2498721162 1180 1000 181 150Ave

PCB-1260 Peak 8 1900217245 1100 1000 102 150Ave

DCB Decachlorobiphenyl 482177470701 102 100 24 150Ave

FORM VII 8082

10162012Page 261 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-1

TestAmerica Edison

Lab File ID vr479493d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 206 201 215

PCB-1016 Peak 2 250 246 260

PCB-1016 Peak 3 275 271 285

PCB-1016 Peak 4 310 306 320

PCB-1016 Peak 5 330 326 340

PCB-1016 Peak 6 365 361 375

PCB-1016 Peak 7 401 397 411

PCB-1016 Peak 8 416 412 426

PCB-1260 Peak 1 604 600 614

PCB-1260 Peak 2 650 645 659

PCB-1260 Peak 3 694 689 703

PCB-1260 Peak 4 714 709 723

PCB-1260 Peak 5 757 753 767

PCB-1260 Peak 6 886 882 896

PCB-1260 Peak 7 908 904 918

PCB-1260 Peak 8 1013 1008 1022

DCB Decachlorobiphenyl 1061 1052 1072

Form VII 8082

10162012Page 262 of 323

Data File vr479493d Page 1 Report Date 09-Oct-2012 0318

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479493dLab Smp Id ccvrtsg1660l3_00019 Inj Date 08-OCT-2012 1830 Operator Inst ID PESTGC9iSmp Info ccvrt-sg1660l3_00019Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 21 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2056 2085 -0029 13178629 826281 550 8000- 12000 10000(M)

2498 2527 -0029 24921299 915181 610 13324- 19985 18910

2746 2777 -0031 17517717 975756 650 9975- 14963 13293

3100 3130 -0030 55834574 938480 620 29367- 44051 42368

3297 3330 -0033 22240639 971476 650 11758- 17638 16876

3648 3685 -0037 23838665 100597 670 11464- 17196 18089

4011 4043 -0032 22339236 996719 660 11819- 17728 16951

4157 4191 -0034 11029779 108584 720 5577- 8366 8369

Average of Peak Concentrations = 640

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6045 6072 -0027 32414247 991956 660 8000- 12000 10000(M)

10162012Page 263 of 323

Data File vr479493d Page 2 Report Date 09-Oct-2012 0318

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6496 6522 -0026 60686283 100362 670 14654- 21981 18722

6938 6964 -0026 57521890 103733 690 14108- 21162 17746

7137 7165 -0028 29736966 985849 660 7567- 11351 9174

7572 7602 -0030 27208663 100536 670 7053- 10579 8394

8857 8893 -0036 33916486 986885 660 9199- 13799 10463

9076 9115 -0039 24987061 118075 790 5953- 8930 7709

10135 10153 -0018 19001807 110187 730 4647- 6971 5862

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 48217685 102438 68 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 264 of 323

Data File vr479493d

Date 08-OCT-2012 1830

Client ID Instrument PESTGC9i

Sample Info ccvrt-sg1660l3_00019 Operator

10162012Page 265 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-2

TestAmerica Edison

Lab File ID vf479510d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 998310273 972 1000 -28 150Ave

PCB-1016 Peak 2 2182221113 1030 1000 34 150Ave

PCB-1016 Peak 3 93438714 1070 1000 72 150Ave

PCB-1016 Peak 4 3888937710 1030 1000 31 150Ave

PCB-1016 Peak 5 1831616455 1110 1000 113 150Ave

PCB-1016 Peak 6 100909770 1030 1000 33 150Ave

PCB-1016 Peak 7 1211711990 1010 1000 11 150Ave

PCB-1016 Peak 8 1287812146 1060 1000 60 150Ave

PCB-1260 Peak 1 2305022106 1040 1000 43 150Ave

PCB-1260 Peak 2 2601125092 1040 1000 37 150Ave

PCB-1260 Peak 3 4009636867 1090 1000 88 150Ave

PCB-1260 Peak 4 1793216241 1100 1000 104 150Ave

PCB-1260 Peak 5 100168814 1140 1000 136 150Ave

PCB-1260 Peak 6 1799416926 1060 1000 63 150Ave

PCB-1260 Peak 7 2148621064 1020 1000 20 150Ave

PCB-1260 Peak 8 78557857 1000 1000 -00 150Ave

DCB Decachlorobiphenyl 262499265963 987 100 -13 150Ave

FORM VII 8082

10162012Page 266 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-2

TestAmerica Edison

Lab File ID vf479510d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 292 289 303

PCB-1016 Peak 2 359 357 371

PCB-1016 Peak 3 403 401 415

PCB-1016 Peak 4 443 441 455

PCB-1016 Peak 5 468 465 479

PCB-1016 Peak 6 511 509 523

PCB-1016 Peak 7 550 547 561

PCB-1016 Peak 8 571 568 582

PCB-1260 Peak 1 770 769 783

PCB-1260 Peak 2 816 814 828

PCB-1260 Peak 3 902 901 915

PCB-1260 Peak 4 927 926 940

PCB-1260 Peak 5 940 938 952

PCB-1260 Peak 6 986 983 997

PCB-1260 Peak 7 1059 1055 1069

PCB-1260 Peak 8 1106 1102 1116

DCB Decachlorobiphenyl 1149 1141 1161

Form VII 8082

10162012Page 267 of 323

Data File vf479510d Report Date 09-Oct-2012 0335

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479510dLab Smp Id ccv-SG1660L3_00019 Inj Date 09-OCT-2012 0147 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 40 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2922 2961 -0039 9983429 971845 650 8000- 12000 10000(M)

3591 3641 -0050 21822420 103360 690 16892- 25338 21859

4034 4085 -0051 9342806 107216 710 6889- 10334 9358

4431 4479 -0048 38888611 103125 690 30481- 45721 38953

4677 4722 -0045 18315559 111308 740 13320- 19980 18346

5112 5158 -0046 10089629 103269 690 7564- 11346 10106

5497 5542 -0045 12117410 101063 670 9332- 13998 12138

5706 5752 -0046 12878214 106025 710 9784- 14675 12900

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7703 7756 -0053 23050032 104269 700 8000- 12000 10000(M)

10162012Page 268 of 323

Data File vf479510d Report Date 09-Oct-2012 0335

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8159 8215 -0056 26011086 103662 690 9103- 13655 11285

9017 9084 -0067 40095841 108759 720 14090- 21136 17395

9273 9332 -0059 17931794 110413 740 6105- 9158 7780

9399 9454 -0055 10016237 113634 760 3460- 5190 4345

9858 9901 -0043 17994170 106314 710 6444- 9666 7807

10594 10616 -0022 21485546 102003 680 7926- 11889 12478

11061 11086 -0025 7855172 999743 670 2968- 4452 3408

Average of Peak Concentrations = 710

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11485 11515 -0030 26249946 986977 66 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 269 of 323

Data File vf479510d

Date 09-OCT-2012 0147

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 270 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-1

TestAmerica Edison

Lab File ID vr479510d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1577315949 989 1000 -11 150Ave

PCB-1016 Peak 2 2637627231 969 1000 -31 150Ave

PCB-1016 Peak 3 1911517953 1060 1000 65 150Ave

PCB-1016 Peak 4 5729159495 963 1000 -37 150Ave

PCB-1016 Peak 5 2290722894 1000 1000 00 150Ave

PCB-1016 Peak 6 2510823697 1060 1000 60 150Ave

PCB-1016 Peak 7 2349222413 1050 1000 48 150Ave

PCB-1016 Peak 8 1095310158 1080 1000 78 150Ave

PCB-1260 Peak 1 3177332677 972 1000 -28 150Ave

PCB-1260 Peak 2 5864160467 970 1000 -30 150Ave

PCB-1260 Peak 3 5561155452 1000 1000 03 150Ave

PCB-1260 Peak 4 2920530164 968 1000 -32 150Ave

PCB-1260 Peak 5 2692527064 995 1000 -05 150Ave

PCB-1260 Peak 6 3316834367 965 1000 -35 150Ave

PCB-1260 Peak 7 2309521162 1090 1000 91 150Ave

PCB-1260 Peak 8 1649517245 957 1000 -43 150Ave

DCB Decachlorobiphenyl 444399470701 944 100 -56 150Ave

FORM VII 8082

10162012Page 271 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-1

TestAmerica Edison

Lab File ID vr479510d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 206 201 215

PCB-1016 Peak 2 250 246 260

PCB-1016 Peak 3 275 271 285

PCB-1016 Peak 4 310 306 320

PCB-1016 Peak 5 330 326 340

PCB-1016 Peak 6 365 361 375

PCB-1016 Peak 7 401 397 411

PCB-1016 Peak 8 416 412 426

PCB-1260 Peak 1 604 600 614

PCB-1260 Peak 2 649 645 659

PCB-1260 Peak 3 694 689 703

PCB-1260 Peak 4 714 709 723

PCB-1260 Peak 5 757 753 767

PCB-1260 Peak 6 885 882 896

PCB-1260 Peak 7 907 904 918

PCB-1260 Peak 8 1013 1008 1022

DCB Decachlorobiphenyl 1061 1052 1072

Form VII 8082

10162012Page 272 of 323

Data File vr479510d Page 1 Report Date 09-Oct-2012 0335

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479510dLab Smp Id ccv-SG1660L3_00019 Inj Date 09-OCT-2012 0147 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 40 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2056 2085 -0029 15772630 988922 660 8000- 12000 10000(M)

2498 2527 -0029 26375750 968593 640 13324- 19985 16722

2747 2777 -0030 19114706 106471 710 9975- 14963 12119

3099 3130 -0031 57290957 962959 640 29367- 44051 36323

3296 3330 -0034 22907341 100060 670 11758- 17638 14523

3645 3685 -0040 25108132 105954 710 11464- 17196 15919

4009 4043 -0034 23491941 104815 700 11819- 17728 14894

4155 4191 -0036 10952986 107828 720 5577- 8366 6944

Average of Peak Concentrations = 680

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6043 6072 -0029 31772880 972329 650 8000- 12000 10000(M)

10162012Page 273 of 323

Data File vr479510d Page 2 Report Date 09-Oct-2012 0335

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6494 6522 -0028 58641225 969803 650 14654- 21981 18456

6936 6964 -0028 55611337 100287 670 14108- 21162 17503

7135 7165 -0030 29205460 968228 640 7567- 11351 9192

7570 7602 -0032 26925453 994891 660 7053- 10579 8474

8854 8893 -0039 33168029 965107 640 9199- 13799 10439

9072 9115 -0043 23094940 109134 730 5953- 8930 7269

10132 10153 -0021 16495029 956510 640 4647- 6971 5192

Average of Peak Concentrations = 660

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 44439946 944122 63 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 274 of 323

Data File vr479510d

Date 09-OCT-2012 0147

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 275 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1309971-A

Matrix vf479496dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2208

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

88 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 276 of 323

Data File vf479496d Report Date 09-Oct-2012 0319

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479496dLab Smp Id MB 460-1309971-a Inj Date 08-OCT-2012 2208 Operator Inst ID PESTGC9iSmp Info MB 460-1309971-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 24 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11484 11515 -0031 23517325 884233 59 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 277 of 323

Data File vf479496d

Date 08-OCT-2012 2208

Client ID Instrument PESTGC9i

Sample Info MB 460-1309971-a Operator

10162012Page 278 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1309971-A

Matrix vr479496dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2208

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

97 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 279 of 323

Data File vr479496d Page 1 Report Date 09-Oct-2012 0319

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479496dLab Smp Id MB 460-1309971-a Inj Date 08-OCT-2012 2208 Operator Inst ID PESTGC9iSmp Info MB 460-1309971-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 24 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 45589434 968543 64 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 280 of 323

Data File vr479496d

Date 08-OCT-2012 2208

Client ID Instrument PESTGC9i

Sample Info MB 460-1309971-a Operator

10162012Page 281 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-1311371

Matrix vf479492dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10082012 1814Sample wtvol

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

114 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 282 of 323

Data File vf479492d Page 1 Report Date 09-Oct-2012 0317

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479492dLab Smp Id piblk-sgpiblk_00013 Inj Date 08-OCT-2012 1814 Operator Inst ID PESTGC9iSmp Info sgpiblk_00013Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 20 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11496 11515 -0019 6086041 228830 15 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 283 of 323

Data File vf479492d

Date 08-OCT-2012 1814

Client ID Instrument PESTGC9i

Sample Info sgpiblk_00013 Operator

10162012Page 284 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-1311371

Matrix vr479492dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10082012 1814Sample wtvol

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

114 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 285 of 323

Data File vr479492d Report Date 09-Oct-2012 0317

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479492dLab Smp Id piblk-sgpiblk_00013 Inj Date 08-OCT-2012 1814 Operator Inst ID PESTGC9iSmp Info sgpiblk_00013Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 20 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 10738471 228138 15 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 286 of 323

Data File vr479492d

Date 08-OCT-2012 1814

Client ID Instrument PESTGC9i

Sample Info sgpiblk_00013 Operator

10162012Page 287 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-13113718

Matrix vf479509dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10092012 0131Sample wtvol

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

122 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 288 of 323

Data File vf479509d Report Date 09-Oct-2012 0313

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479509dLab Smp Id SGPIBLK_00013 Inj Date 09-OCT-2012 0131 Operator Inst ID PESTGC9iSmp Info SGPIBLK_00013Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 39 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11487 11515 -0028 6469383 243244 16 8000- 12000 10000(a)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 289 of 323

Data File vf479509d

Date 09-OCT-2012 0131

Client ID Instrument PESTGC9i

Sample Info SGPIBLK_00013 Operator

10162012Page 290 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-13113718

Matrix vr479509dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10092012 0131Sample wtvol

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

102 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 291 of 323

Data File vr479509d Report Date 09-Oct-2012 0306

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479509dLab Smp Id SGPIBLK_00013 Inj Date 09-OCT-2012 0131 Operator Inst ID PESTGC9iSmp Info SGPIBLK_00013Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 39 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 9634357 204681 14 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 292 of 323

Data File vr479509d

Date 09-OCT-2012 0131

Client ID Instrument PESTGC9i

Sample Info SGPIBLK_00013 Operator

10162012Page 293 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1309972-A

Matrix vf479497dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2224

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 507

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 557

RECCAS NO LIMITSQSURROGATE

84 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 294 of 323

Data File vf479497d Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479497dLab Smp Id LCS 460-1309972-a Inj Date 08-OCT-2012 2224 Operator Inst ID PESTGC9iSmp Info LCS 460-1309972-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 25 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2926 2961 -0035 10792080 105056 700 8000- 12000 10000

3596 3641 -0045 23726579 112379 750 16892- 25338 21985

4040 4085 -0045 9881475 113398 760 6889- 10334 9156

4437 4479 -0042 42082916 111596 740 30481- 45721 38994

4683 4722 -0039 19556228 118847 790 13320- 19980 18121

5181 5158 0023 7863050 804795 540 7564- 11346 7286

5572 5542 0030 6208245 517785 340 9332- 13998 5753

5713 5752 -0039 14198514 116895 780 9784- 14675 13156

Average of Peak Concentrations = 680

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7711 7756 -0045 26515963 119947 800 8000- 12000 10000(M)

10162012Page 295 of 323

Data File vf479497d Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8168 8215 -0047 29809525 118800 790 9103- 13655 11242

9026 9084 -0058 46049501 124909 830 14090- 21136 17367

9283 9332 -0049 20194161 124344 830 6105- 9158 7616

9408 9454 -0046 11340121 128654 860 3460- 5190 4277

9864 9901 -0037 20709127 122354 820 6444- 9666 7810

10623 10616 0007 8913638 423178 280 7926- 11889 3362

11063 11086 -0023 8650385 110095 730 2968- 4452 3262

Average of Peak Concentrations = 740

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11484 11515 -0031 22216113 835308 56 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 296 of 323

Data File vf479497d

Date 08-OCT-2012 2224

Client ID Instrument PESTGC9i

Sample Info LCS 460-1309972-a Operator

10162012Page 297 of 323

Manual Integration Report

Data File vf479497dInj Date and Time 08-OCT-2012 2224Instrument ID PESTGC9iClient ID Compound 27 Aroclor-1260CAS 11096-82-5Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 776

Manual Integration Results

RT 771

Response 26515963

Amount 111428

Conc 74000

Manually Integrated By diazcManual Integration Reason

10162012Page 298 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1309972-A

Matrix vr479497dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2224

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 483

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 573

RECCAS NO LIMITSQSURROGATE

91 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 299 of 323

Data File vr479497d Page 1 Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479497dLab Smp Id LCS 460-1309972-a Inj Date 08-OCT-2012 2224 Operator Inst ID PESTGC9iSmp Info LCS 460-1309972-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 25 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2058 2085 -0027 15080112 945502 630 8000- 12000 10000(M)

2502 2527 -0025 26928755 988901 660 13324- 19985 17857

2750 2777 -0027 19042665 106070 710 9975- 14963 12628

3103 3130 -0027 59594211 100167 670 29367- 44051 39518

3301 3330 -0029 23808984 103998 690 11758- 17638 15788

3694 3685 0009 14297782 603352 400 11464- 17196 9481

4013 4043 -0030 24245185 108176 720 11819- 17728 16078

4188 4191 -0003 10255607 100963 670 5577- 8366 6801

Average of Peak Concentrations = 640

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6048 6072 -0024 36196886 110771 740 8000- 12000 10000

10162012Page 300 of 323

Data File vr479497d Page 2 Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6500 6522 -0022 67525585 111673 740 14654- 21981 18655

6943 6964 -0021 64479188 116279 780 14108- 21162 17813

7142 7165 -0023 33072749 109644 730 7567- 11351 9137

7578 7602 -0024 30577540 112984 750 7053- 10579 8448

8864 8893 -0029 38421619 111797 740 9199- 13799 10615

9083 9115 -0032 26202367 123818 820 5953- 8930 7239

10138 10153 -0015 20706585 120073 800 4647- 6971 5721

Average of Peak Concentrations = 760

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 42991277 913346 61 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 301 of 323

Data File vr479497d

Date 08-OCT-2012 2224

Client ID Instrument PESTGC9i

Sample Info LCS 460-1309972-a Operator

10162012Page 302 of 323

Manual Integration Report

Data File vr479497dInj Date and Time 08-OCT-2012 2224Instrument ID PESTGC9iClient ID Compound 21 Aroclor-1016CAS 12674-11-2Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 208

Manual Integration Results

RT 206

Response 15080112

Amount 96644

Conc 64000

Manually Integrated By diazcManual Integration Reason

10162012Page 303 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCSD 460-1309973-A

Matrix vf479498dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2239

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 516

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 583

RECCAS NO LIMITSQSURROGATE

99 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 304 of 323

Data File vf479498d Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479498dLab Smp Id LCSd 460-1309973-a Inj Date 08-OCT-2012 2239 Operator Inst ID PESTGC9iSmp Info LCSd 460-1309973-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 26 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2925 2961 -0036 10994509 107027 710 8000- 12000 10000

3594 3641 -0047 24222192 114726 760 16892- 25338 22031

4039 4085 -0046 9969671 114410 760 6889- 10334 9068

4435 4479 -0044 43128755 114369 760 30481- 45721 39228

4680 4722 -0042 19946065 121217 810 13320- 19980 18142

5177 5158 0019 7960960 814816 540 7564- 11346 7241

5569 5542 0027 6392667 533166 360 9332- 13998 5814

5711 5752 -0041 14546887 119763 800 9784- 14675 13231

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7708 7756 -0048 27193660 123013 820 8000- 12000 10000(M)

10162012Page 305 of 323

Data File vf479498d Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8164 8215 -0051 30632211 122078 810 9103- 13655 11264

9022 9084 -0062 47541251 128955 860 14090- 21136 17482

9278 9332 -0054 21062846 129693 860 6105- 9158 7745

9404 9454 -0050 11787377 133728 890 3460- 5190 4335

9862 9901 -0039 21547760 127309 850 6444- 9666 7924

10618 10616 0002 10677528 506919 340 7926- 11889 3926

11062 11086 -0024 9277293 118074 790 2968- 4452 3412

Average of Peak Concentrations = 780

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11482 11515 -0033 26307958 989158 66 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 306 of 323

Data File vf479498d

Date 08-OCT-2012 2239

Client ID Instrument PESTGC9i

Sample Info LCSd 460-1309973-a Operator

10162012Page 307 of 323

Manual Integration Report

Data File vf479498dInj Date and Time 08-OCT-2012 2239Instrument ID PESTGC9iClient ID Compound 27 Aroclor-1260CAS 11096-82-5Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 776

Manual Integration Results

RT 771

Response 27193660

Amount 116693

Conc 78000

Manually Integrated By diazcManual Integration Reason

10162012Page 308 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCSD 460-1309973-A

Matrix vr479498dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2239

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 497

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 595

RECCAS NO LIMITSQSURROGATE

108 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 309 of 323

Data File vr479498d Page 1 Report Date 09-Oct-2012 0321

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479498dLab Smp Id LCSd 460-1309973-a Inj Date 08-OCT-2012 2239 Operator Inst ID PESTGC9iSmp Info LCSd 460-1309973-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 26 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2058 2085 -0027 15401465 965650 640 8000- 12000 10000(M)

2501 2527 -0026 27477458 100905 670 13324- 19985 17841

2750 2777 -0027 19458638 108387 720 9975- 14963 12634

3102 3130 -0028 60672366 101979 680 29367- 44051 39394

3299 3330 -0031 24206974 105737 700 11758- 17638 15717

3679 3685 -0006 17478185 737562 490 11464- 17196 11348

4012 4043 -0031 24592091 109724 730 11819- 17728 15967

4189 4191 -0002 9970290 981538 650 5577- 8366 6474

Average of Peak Concentrations = 660

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6047 6072 -0025 36957605 113099 750 8000- 12000 10000

10162012Page 310 of 323

Data File vr479498d Page 2 Report Date 09-Oct-2012 0321

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6498 6522 -0024 69036402 114172 760 14654- 21981 18680

6940 6964 -0024 66037968 119090 790 14108- 21162 17869

7140 7165 -0025 33956993 112575 750 7567- 11351 9188

7575 7602 -0027 31643763 116923 780 7053- 10579 8562

8861 8893 -0032 40016219 116437 780 9199- 13799 10828

9080 9115 -0035 27744305 131104 870 5953- 8930 7507

10136 10153 -0017 22040150 127806 850 4647- 6971 5964

Average of Peak Concentrations = 790

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10612 10624 -0012 50942327 108226 72 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 311 of 323

Data File vr479498d

Date 08-OCT-2012 2239

Client ID Instrument PESTGC9i

Sample Info LCSd 460-1309973-a Operator

10162012Page 312 of 323

Manual Integration Report

Data File vr479498dInj Date and Time 08-OCT-2012 2239Instrument ID PESTGC9iClient ID Compound 21 Aroclor-1016CAS 12674-11-2Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 208

Manual Integration Results

RT 206

Response 15401465

Amount 99401

Conc 66000

Manually Integrated By diazcManual Integration Reason

10162012Page 313 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GC SEMI VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

PESTGC9

129926

Start Date

End Date 09302012 2043

09302012 1530

RINSE 460-1299261 CLP-2 053(mm)109302012 1530

RINSE 460-1299261 CLP-1 053(mm)109302012 1530

RINSE 460-1299262 CLP-2 053(mm)109302012 1546

RINSE 460-1299262 CLP-1 053(mm)109302012 1546

ZZZZZ CLP-2 053(mm)109302012 1602

ZZZZZ CLP-1 053(mm)109302012 1602

ZZZZZ CLP-2 053(mm)109302012 1617

ZZZZZ CLP-1 053(mm)109302012 1617

ZZZZZ CLP-2 053(mm)109302012 1633

ZZZZZ CLP-1 053(mm)109302012 1633

ZZZZZ CLP-2 053(mm)109302012 1649

ZZZZZ CLP-1 053(mm)109302012 1649

IC 460-1299267 CLP-2 053(mm)109302012 1704 vf479200d

IC 460-1299267 CLP-1 053(mm)109302012 1704 vr479200d

IC 460-1299268 CLP-2 053(mm)109302012 1720 vf479201d

IC 460-1299268 CLP-1 053(mm)109302012 1720 vr479201d

IC 460-1299269 CLP-2 053(mm)109302012 1735 vf479202d

IC 460-1299269 CLP-1 053(mm)109302012 1735 vr479202d

IC 460-12992610 CLP-2 053(mm)109302012 1751 vf479203d

IC 460-12992610 CLP-1 053(mm)109302012 1751 vr479203d

IC 460-12992611 CLP-2 053(mm)109302012 1807 vf479204d

IC 460-12992611 CLP-1 053(mm)109302012 1807 vr479204d

IC 460-12992612 CLP-2 053(mm)109302012 1822 vf479205d

IC 460-12992612 CLP-1 053(mm)109302012 1822 vr479205d

IC 460-12992613 CLP-2 053(mm)109302012 1838 vf479206d

IC 460-12992613 CLP-1 053(mm)109302012 1838 vr479206d

IC 460-12992614 CLP-2 053(mm)109302012 1854 vf479207d

IC 460-12992614 CLP-1 053(mm)109302012 1854 vr479207d

IC 460-12992615 CLP-2 053(mm)109302012 1909 vf479208d

IC 460-12992615 CLP-1 053(mm)109302012 1909 vr479208d

IC 460-12992616 CLP-2 053(mm)109302012 1925 vf479209d

IC 460-12992616 CLP-1 053(mm)109302012 1925 vr479209d

IC 460-12992617 CLP-2 053(mm)109302012 1940

IC 460-12992617 CLP-1 053(mm)109302012 1940

IC 460-12992618 CLP-2 053(mm)109302012 1956

IC 460-12992618 CLP-1 053(mm)109302012 1956

ZZZZZ CLP-2 053(mm)109302012 2011

ZZZZZ CLP-1 053(mm)109302012 2011

ZZZZZ CLP-2 053(mm)109302012 2027

ZZZZZ CLP-1 053(mm)109302012 2027

ZZZZZ CLP-2 053(mm)109302012 2043

ZZZZZ CLP-1 053(mm)109302012 2043

8082

10162012Page 314 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GC SEMI VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

PESTGC9

131137

Start Date

End Date 10092012 0147

10082012 1814

PIBLK 460-1311371 CLP-2 053(mm)110082012 1814 vf479492d

PIBLK 460-1311371 CLP-1 053(mm)110082012 1814 vr479492d

CCVRT 460-1311372 CLP-2 053(mm)110082012 1830 vf479493d

CCVRT 460-1311372 CLP-1 053(mm)110082012 1830 vr479493d

ZZZZZ CLP-2 053(mm)110082012 2137

ZZZZZ CLP-1 053(mm)110082012 2137

ZZZZZ CLP-2 053(mm)110082012 2152

ZZZZZ CLP-1 053(mm)110082012 2152

MB 460-1309971-A CLP-2 053(mm)110082012 2208 vf479496d

MB 460-1309971-A CLP-1 053(mm)110082012 2208 vr479496d

LCS 460-1309972-A CLP-2 053(mm)110082012 2224 vf479497d

LCS 460-1309972-A CLP-1 053(mm)110082012 2224 vr479497d

LCSD 460-1309973-A CLP-2 053(mm)110082012 2239 vf479498d

LCSD 460-1309973-A CLP-1 053(mm)110082012 2239 vr479498d

ZZZZZ CLP-2 053(mm)110082012 2255

ZZZZZ CLP-1 053(mm)110082012 2255

ZZZZZ CLP-2 053(mm)110082012 2311

ZZZZZ CLP-1 053(mm)110082012 2311

ZZZZZ CLP-2 053(mm)110082012 2326

ZZZZZ CLP-1 053(mm)110082012 2326

ZZZZZ CLP-2 053(mm)110082012 2342

ZZZZZ CLP-1 053(mm)110082012 2342

ZZZZZ CLP-2 053(mm)110082012 2358

ZZZZZ CLP-1 053(mm)110082012 2358

ZZZZZ CLP-2 053(mm)110092012 0013

ZZZZZ CLP-1 053(mm)110092012 0013

460-45537-1 WC-17338-100512-MW14-MM-251

CLP-2 053(mm)110092012 0029 vf479505d

460-45537-1 WC-17338-100512-MW14-MM-251

CLP-1 053(mm)110092012 0029 vr479505d

460-45537-2 WC-17338-100512-MW101-MM-252

CLP-2 053(mm)110092012 0045 vf479506d

460-45537-2 WC-17338-100512-MW101-MM-252

CLP-1 053(mm)110092012 0045 vr479506d

ZZZZZ CLP-2 053(mm)110092012 0100

ZZZZZ CLP-1 053(mm)110092012 0100

ZZZZZ CLP-2 053(mm)110092012 0116

ZZZZZ CLP-1 053(mm)110092012 0116

PIBLK 460-13113718 CLP-2 053(mm)110092012 0131 vf479509d

PIBLK 460-13113718 CLP-1 053(mm)110092012 0131 vr479509d

CCV 460-13113719 CLP-2 053(mm)110092012 0147 vf479510d

CCV 460-13113719 CLP-1 053(mm)110092012 0147 vr479510d

8082

10162012Page 315 of 323

10162012Page 316 of 323

10162012Page 317 of 323

10162012Page 318 of 323

10162012Page 319 of 323

Lab Name Job No

SDG No

GC SEMI VOA BATCH WORKSHEET

460-45537-1

Batch Number Batch AnalystBatch Start Date

Batch End Date

Wu Huachi

100812 1800

100812 0754130997

Batch Method

TestAmerica Edison

3510C

Lab Sample ID Client Sample ID Method Chain Basis ReceivedpH InitialAmount FinalAmount OP_PCBSP 00024 OPPSTPCBSU 00021

AnalysisComment

7 1000 mL 5 mL 50 uL Acid Cleaning_UP

MB 460-1309971 3510C 8082

7 1000 mL 5 mL 50 uL 50 uL Acid Cleaning_UP

LCS 460-1309972

3510C 8082

7 1000 mL 5 mL 50 uL 50 uL Acid Cleaning_UP

LCSD 460-1309973

3510C 8082

WC-17338-100512-MW14-MM-251

7 980 mL 5 mL 50 uL Acid Cleaning_UP

460-45537-E-1 3510C 8082 T

WC-17338-100512-MW101-MM-252

7 990 mL 5 mL 50 uL Acid Cleaning_UP

460-45537-E-2 3510C 8082 T

Batch Notes

Batch Comment 8082Acid Cleaning_up Lot 20042

Persons name who did the concentration Wuh

Exchange Solvent Lot 6383

Exchange Solvent Name Hexane

Final Concentrator Volume 5 mL

N-evap temperature 35 Degrees C

Na2SO4 Lot Number 213204

Prep Solvent Lot 14764

Prep Solvent Name Mecl2

Prep Solvent Volume Used 180 ml mL

Persons name who did the prep Wuh

Persons name who witnessed reagent drop HCP

Basis Basis Description

T TotalNA

Page 1 of 18082

10162012Page 320 of 323

Shipping and

Receiving

Documents

10162012Page 321 of 323

10162012Page 322 of 323

Login Sample Receipt Checklist

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Login Number 45537

Question Answer Comment

Creator Hall Alonzo

List Source TestAmerica Edison

List Number 1

NARadioactivity wasnt checked or is lt= background as measured by a survey

meter

NAThe coolers custody seal if present is intact Not present

TrueSample custody seals if present are intact

TrueThe cooler or samples do not appear to have been compromised or

tampered with

TrueSamples were received on ice

TrueCooler Temperature is acceptable

TrueCooler Temperature is recorded 32deg C IR 2

TrueCOC is present

TrueCOC is filled out in ink and legible

TrueCOC is filled out with all pertinent information

TrueIs the Field Samplers name present on COC

TrueThere are no discrepancies between the containers received and the COC

TrueSamples are received within Holding Time

TrueSample containers have legible labels

TrueContainers are not broken or leaking

TrueSample collection datetimes are provided

TrueAppropriate sample containers are used

TrueSample bottles are completely filled

TrueSample Preservation Verified

TrueThere is sufficient vol for all requested analyses incl any requested

MSMSDs

TrueContainers requiring zero headspace have no headspace or bubble is

lt6mm (14)

NAMultiphasic samples are not present

NASamples do not require splitting or compositing

NAResidual Chlorine Checked No analysis requiring residual chlorine check

assigned

TestAmerica Edison 10162012Page 323 of 323

  • Cover Title Page
  • Table of Contents
  • Data Summaries
    • Report Narrative
    • Sample Summary
    • Executive Summary
    • Method Summary
    • Method Analyst Summary
    • Sample Datasheets
    • Surrogate Summary
    • QC Data Summary
    • Data Qualifiers
    • QC Association Summary
    • Lab Chronicle
      • Organic Sample Data
        • GCMS VOA
          • Method 8260 DEL
            • Method 8260 DEL QC Summary
            • Method 8260 DEL Sample Data
            • Standards Data
              • Method 8260 DEL ICAL Data
              • Method 8260 DEL CCAL Data
                • Raw QC Data
                  • Method 8260 DEL Tune Data
                  • Method 8260 DEL Blank Data
                  • Method 8260 DEL LCSLCSD Data
                  • Method 8260 DEL MSMSD Data
                    • Method 8260 DEL Run Logs
                    • Method 8260 DEL Prep Data
                        • GC Semi VOA
                          • Method 8082 - Delaware
                            • Method 8082 - Delaware QC Summary
                            • Method 8082 - Delaware Sample Data
                            • Standards Data
                              • Method 8082 - Delaware ICAL Data
                              • Method 8082 - Delaware CCAL Data
                                • Raw QC Data
                                  • Method 8082 - Delaware Blank Data
                                  • Method 8082 - Delaware LCSLCSD Data
                                    • Method 8082 - Delaware Run Logs
                                    • Method 8082 - Delaware Prep Data
                                      • Shipping and Receiving Documents
                                        • Client Chain of Custody
                                        • Sample Receipt Checklist
Page 6: J45537-1 Nj Full Package Final Report

EXECUTIVE SUMMARY - Detections

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Analyte Result

Reporting

Limit Units Method

Lab Sample ID Client Sample ID

Qualifier

460-45537-1 WC-17338-100512-MW14-MM-251

10 ugL 8260B017 JMethyl tert-butyl ether

10 ugL 8260B017 JToluene

10 ugL 8260B028 JTetrachloroethene

460-45537-2 WC-17338-100512-MW101-MM-252

10 ugL 8260B020 JMethyl tert-butyl ether

460-45537-3TB TB-17338-100512-253

10 ugL 8260B074 JMethylene Chloride

10 ugL 8260B0096 JChloroform

TestAmerica Edison 10162012Page 6 of 323

METHOD SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Preparation MethodMethodLab LocationDescription

Matrix Water

Volatile Organics (GCMS) TAL EDI SW846 8260B

Purge and Trap TAL EDI SW846 5030B

Polychlorinated Biphenyls (PCBs) (GC) TAL EDI SW846 8082

Liquid-Liquid Extraction (Separatory Funnel) TAL EDI SW846 3510C

Lab References

TAL EDI = TestAmerica Edison

Method References

SW846 = Test Methods For Evaluating Solid Waste PhysicalChemical Methods Third Edition November 1986 And Its Updates

TestAmerica Edison 10162012Page 7 of 323

METHOD ANALYST SUMMARY

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Method Analyst Analyst ID

Boykin Kenneth KBSW846 8260B

Boykin Carol B CBBSW846 8082

TestAmerica Edison

10162012Page 8 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

017 J 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

017 J 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

028 J 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 9 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

99 70 - 1304-Bromofluorobenzene

96 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 10 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2341

10112012 2341

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08983d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 11 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

020 J 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 12 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

98 70 - 1304-Bromofluorobenzene

97 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 13 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10122012 0004

10122012 0004

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08984d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 14 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

074 J 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

014 U 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0096 J 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

014 U 1001413-Dichlorobenzene

TestAmerica Edison 10162012Page 15 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance LimitsQualifier

97 70 - 13012-Dichloroethane-d4 (Surr)

99 70 - 1304-Bromofluorobenzene

97 70 - 130Toluene-d8 (Surr)

TestAmerica Edison 10162012Page 16 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

TB-17338-100512-253

Client Matrix

460-45537-3TB

Water

Date Sampled 10052012 0000

Date Received 10052012 1910

8260B Volatile Organics (GCMS)

Dilution

10112012 2317

10112012 2317

10

8260B

Final WeightVolume

Initial WeightVolume

Lab File ID

Instrument ID

e08982d

5 mL

5 mL

5030B

VOAMS5

Analysis Date

Prep Date

Analysis Batch

Prep Batch

460-131656

NA

Analysis Method

Prep Method

Tentatively Identified Compounds

QualifierEst Result (ugL)RTAnalyteCas Number

0Number TICs Found

NoneTentatively Identified Compound

TestAmerica Edison 10162012Page 17 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0029

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type PRIMARY

980 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

013 U 051013PCB-1016

029 U 051029PCB-1221

012 U 051012PCB-1232

012 U 051012PCB-1242

024 U 051024PCB-1248

017 U 051017PCB-1254

015 U 051015PCB-1260

Surrogate Rec Acceptance LimitsQualifier

83 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 18 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW14-MM-251

Client Matrix

460-45537-1

Water

Date Sampled 10052012 1000

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0029

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type SECONDARY

980 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Surrogate Rec Acceptance LimitsQualifier

82 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 19 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0045

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type PRIMARY

990 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Analyte Result (ugL) Qualifier MDL RL

013 U 051013PCB-1016

028 U 051028PCB-1221

012 U 051012PCB-1232

012 U 051012PCB-1242

024 U 051024PCB-1248

017 U 051017PCB-1254

015 U 051015PCB-1260

Surrogate Rec Acceptance LimitsQualifier

52 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 20 of 323

Analytical Data

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Client Sample ID

Lab Sample ID

WC-17338-100512-MW101-MM-252

Client Matrix

460-45537-2

Water

Date Sampled 10052012 1230

Date Received 10052012 1910

8082 Polychlorinated Biphenyls (PCBs) (GC)

Dilution

8082

3510C

10

10092012 0045

10082012 0755

Instrument ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Result Type SECONDARY

990 mL

5 mL

PESTGC9

Analysis Date

Prep Date

Analysis Batch 460-131137

460-130997Prep Batch

Analysis Method

Prep Method

Surrogate Rec Acceptance LimitsQualifier

50 37 - 150DCB Decachlorobiphenyl

TestAmerica Edison 10162012Page 21 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Surrogate Recovery Report

8260B Volatile Organics (GCMS)

Client Matrix Water

Lab Sample ID Client Sample ID

DCA TOL BFB

Rec Rec Rec

460-45537-1 WC-17338-100512-M

W14-MM-251

97 96 99

460-45537-2 WC-17338-100512-M

W101-MM-252

97 97 98

460-45537-3 TB-17338-100512-25

3

97 97 99

MB 460-1316564 99 96 95

LCS 460-1316563 96 99 97

460-45537-2 MS WC-17338-100512-M

W101-MM-252 MS

96 99 99

460-45537-2 MSD WC-17338-100512-M

W101-MM-252 MSD

96 99 97

Surrogate Acceptance Limits

DCA = 12-Dichloroethane-d4 (Surr) 70-130

TOL = Toluene-d8 (Surr) 70-130

BFB = 4-Bromofluorobenzene 70-130

TestAmerica Edison

10162012Page 22 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Surrogate Recovery Report

8082 Polychlorinated Biphenyls (PCBs) (GC)

Client Matrix Water

Lab Sample ID Client Sample ID

DCB1 DCB2

Rec Rec

460-45537-1 WC-17338-100512-M

W14-MM-251

82 83

460-45537-2 WC-17338-100512-M

W101-MM-252

52 50

MB 460-1309971-A 97 88

LCS 460-1309972-A 91 84

LCSD

460-1309973-A

108 99

Surrogate Acceptance Limits

DCB = DCB Decachlorobiphenyl 37-150

TestAmerica Edison

10162012Page 23 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-131656

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08981d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5MB 460-1316564

Analysis Date 10112012 2247

Analysis Batch

Prep Batch

Leach Batch

NA

NA

460-131656

Prep Date

Leach Date

10112012 2247

NA

Analyte RLMDLQualResult

0060 U 100060111-Trichloroethane

022 U 10022Dichlorodifluoromethane

010 U 10010Chloromethane

014 U 10014Vinyl chloride

018 U 10018Bromomethane

040 U 1004012-Dibromo-3-Chloropropane

021 U 1002112-Dichlorobenzene

015 U 10015Trichlorofluoromethane

0090 U 10009011-Dichloroethene

0090 U 10009012-Dichloropropane

0080 U 100080112-Trichloro-122-trifluoroethane

27 U 5027Acetone

013 U 10013Carbon disulfide

034 U 20034Methyl acetate

018 U 10018Methylene Chloride

013 U 10013trans-12-Dichloroethene

020 U 10020Chlorodibromomethane

014 U 10014Methyl tert-butyl ether

017 U 10017Chloroethane

013 U 1001311-Dichloroethane

018 U 10018cis-12-Dichloroethene

23 U 50232-Butanone (MEK)

0080 U 100080Chloroform

010 U 10010Ethylbenzene

016 U 10016Cyclohexane

0060 U 100060Carbon tetrachloride

0080 U 100080Benzene

019 U 1001912-Dichloroethane

0090 U 100090Trichloroethene

014 U 10014Methylcyclohexane

012 U 10012Dichlorobromomethane

018 U 10018cis-13-Dichloropropene

099 U 500994-Methyl-2-pentanone (MIBK)

015 U 10015Toluene

024 U 10024trans-13-Dichloropropene

019 U 10019112-Trichloroethane

010 U 10010Tetrachloroethene

050 U 500502-Hexanone

028 U 1002812-Dibromoethane

011 U 10011Chlorobenzene

036 U 30036Xylenes Total

012 U 10012Styrene

019 U 10019Bromoform

0080 U 100080Isopropylbenzene

016 U 100161122-Tetrachloroethane

TestAmerica Edison 10162012Page 24 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-131656

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08981d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5MB 460-1316564

Analysis Date 10112012 2247

Analysis Batch

Prep Batch

Leach Batch

NA

NA

460-131656

Prep Date

Leach Date

10112012 2247

NA

Analyte RLMDLQualResult

014 U 1001413-Dichlorobenzene

023 U 1002314-Dichlorobenzene

034 U 10034124-Trichlorobenzene

Surrogate Rec Acceptance Limits

12-Dichloroethane-d4 (Surr) 99 70 - 130

4-Bromofluorobenzene 95 70 - 130

Toluene-d8 (Surr) 96 70 - 130

Method Blank TICs- Batch 460-131656

Cas Number Analyte RT Est Result Qual

Tentatively Identified Compound None

TestAmerica Edison 10162012Page 25 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10

Lab Control Sample - Batch 460-131656

Client Matrix

Lab Sample ID

Dilution

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08977d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5LCS 460-1316563

Analysis Date 10112012 2113

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Prep Date

Leach Date

10112012 2113

NA

Analyte QualLimit RecResultSpike Amount

200 210 105 74 - 128111-Trichloroethane

200 181 90 46 - 145Dichlorodifluoromethane

200 210 105 58 - 146Chloromethane

200 203 101 61 - 144Vinyl chloride

200 211 105 55 - 153Bromomethane

200 222 111 70 - 11612-Dibromo-3-Chloropropane

200 209 104 82 - 12212-Dichlorobenzene

200 190 95 69 - 147Trichlorofluoromethane

200 223 112 56 - 13911-Dichloroethene

200 211 106 80 - 12012-Dichloropropane

200 203 102 47 - 139112-Trichloro-122-trifluoroethane

200 250 125 45 - 156Acetone

200 218 109 58 - 139Carbon disulfide

200 220 110 50 - 151Methyl acetate

200 200 100 79 - 119Methylene Chloride

200 216 108 75 - 122trans-12-Dichloroethene

200 217 109 80 - 120Chlorodibromomethane

200 207 104 71 - 115Methyl tert-butyl ether

200 201 101 69 - 145Chloroethane

200 204 102 78 - 12211-Dichloroethane

200 211 106 80 - 120cis-12-Dichloroethene

200 214 107 65 - 1142-Butanone (MEK)

200 205 103 82 - 123Chloroform

200 206 103 79 - 126Ethylbenzene

200 208 104 58 - 133Cyclohexane

200 211 105 73 - 120Carbon tetrachloride

200 212 106 83 - 124Benzene

200 204 102 74 - 11812-Dichloroethane

200 212 106 78 - 119Trichloroethene

200 215 107 61 - 129Methylcyclohexane

200 214 107 79 - 119Dichlorobromomethane

200 216 108 80 - 120cis-13-Dichloropropene

200 214 107 53 - 1204-Methyl-2-pentanone (MIBK)

200 205 103 80 - 120Toluene

200 215 108 78 - 118trans-13-Dichloropropene

200 217 109 79 - 119112-Trichloroethane

200 210 105 68 - 139Tetrachloroethene

200 201 100 53 - 1212-Hexanone

200 215 107 78 - 11812-Dibromoethane

200 206 103 81 - 121Chlorobenzene

600 612 102 76 - 121Xylenes Total

200 207 104 69 - 112Styrene

200 217 109 73 - 123Bromoform

200 207 104 80 - 125Isopropylbenzene

200 210 105 74 - 1261122-Tetrachloroethane

200 204 102 81 - 12613-Dichlorobenzene

TestAmerica Edison 10162012Page 26 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10

Lab Control Sample - Batch 460-131656

Client Matrix

Lab Sample ID

Dilution

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

e08977d

5 mL

5 mLUnits ugL

Method 8260B

Preparation 5030B

VOAMS5LCS 460-1316563

Analysis Date 10112012 2113

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Prep Date

Leach Date

10112012 2113

NA

Analyte QualLimit RecResultSpike Amount

200 204 102 83 - 12314-Dichlorobenzene

200 220 110 66 - 120124-Trichlorobenzene

Surrogate Rec Acceptance Limits

12-Dichloroethane-d4 (Surr) 96 70 - 130

4-Bromofluorobenzene 97 70 - 130

Toluene-d8 (Surr) 99 70 - 130

TestAmerica Edison 10162012Page 27 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Water

50

50

Client Matrix

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Client Matrix Water

e08985d

5 mL

5 mL

e08986d

5 mL

5 mL

Method 8260B

Preparation 5030B

VOAMS5

VOAMS5

460-45537-2

460-45537-2

MS Lab Sample ID

MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

10122012 0051

NA

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

10122012 0027

Analyte RPD LimitRPDLimit

Rec

MS MSD MS Qual MSD Qual

103 106 74 - 128 3 30111-Trichloroethane

87 90 46 - 145 4 30Dichlorodifluoromethane

102 101 58 - 146 0 30Chloromethane

104 105 61 - 144 0 30Vinyl chloride

107 105 55 - 153 2 30Bromomethane

121 121 70 - 116 0 30 F F12-Dibromo-3-Chloropropane

107 111 82 - 122 3 3012-Dichlorobenzene

121 100 69 - 147 19 30Trichlorofluoromethane

108 119 56 - 139 9 3011-Dichloroethene

111 110 80 - 120 0 3012-Dichloropropane

102 111 47 - 139 8 30112-Trichloro-122-trifluoroethane

99 101 45 - 156 2 30Acetone

113 119 58 - 139 5 30Carbon disulfide

100 101 50 - 151 1 30Methyl acetate

106 106 79 - 119 0 30Methylene Chloride

106 108 75 - 122 2 30trans-12-Dichloroethene

116 118 80 - 120 2 30Chlorodibromomethane

114 116 71 - 115 1 30 FMethyl tert-butyl ether

116 105 69 - 145 10 30Chloroethane

104 111 78 - 122 7 3011-Dichloroethane

105 109 80 - 120 4 30cis-12-Dichloroethene

111 114 65 - 114 3 302-Butanone (MEK)

108 113 82 - 123 4 30Chloroform

107 111 79 - 126 3 30Ethylbenzene

108 117 58 - 133 7 30Cyclohexane

105 110 73 - 120 5 30Carbon tetrachloride

106 114 83 - 124 7 30Benzene

107 109 74 - 118 2 3012-Dichloroethane

107 113 78 - 119 5 30Trichloroethene

115 121 61 - 129 5 30Methylcyclohexane

113 116 79 - 119 3 30Dichlorobromomethane

109 115 80 - 120 5 30cis-13-Dichloropropene

111 114 53 - 120 3 304-Methyl-2-pentanone (MIBK)

TestAmerica Edison 10162012Page 28 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Water

50

50

Client Matrix

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Client Matrix Water

e08985d

5 mL

5 mL

e08986d

5 mL

5 mL

Method 8260B

Preparation 5030B

VOAMS5

VOAMS5

460-45537-2

460-45537-2

MS Lab Sample ID

MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

10122012 0051

NA

Analysis Batch

Prep Batch

Leach Batch

460-131656

NA

NA

10122012 0027

Analyte RPD LimitRPDLimit

Rec

MS MSD MS Qual MSD Qual

106 111 80 - 120 5 30Toluene

113 119 78 - 118 5 30 Ftrans-13-Dichloropropene

112 116 79 - 119 3 30112-Trichloroethane

110 116 68 - 139 5 30Tetrachloroethene

109 111 53 - 121 2 302-Hexanone

116 117 78 - 118 1 3012-Dibromoethane

107 111 81 - 121 3 30Chlorobenzene

106 110 76 - 121 3 30Xylenes Total

107 110 69 - 112 3 30Styrene

115 114 73 - 123 1 30Bromoform

107 111 80 - 125 4 30Isopropylbenzene

115 116 74 - 126 0 301122-Tetrachloroethane

106 110 81 - 126 4 3013-Dichlorobenzene

106 110 83 - 123 4 3014-Dichlorobenzene

110 119 66 - 120 8 30124-Trichlorobenzene

Surrogate Acceptance LimitsMS Rec MSD Rec

12-Dichloroethane-d4 (Surr) 96 96 70 - 130

4-Bromofluorobenzene 99 97 70 - 130

Toluene-d8 (Surr) 99 99 70 - 130

TestAmerica Edison 10162012Page 29 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10122012 0027 10122012 0051

Dilution Dilution50 50

Client Matrix Client Matrix Water

Method 8260B

Preparation 5030B

Units ugL460-45537-2 460-45537-2MS Lab Sample ID MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

Analysis Date

Prep Date

Leach Date

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

NA

Amount

Sample

Analyte ResultQual Amount ResultQual ResultQual

MS MSDMS Spike MSD Spike

0060 U 100 100 103 106111-Trichloroethane

022 U 100 100 865 896Dichlorodifluoromethane

010 U 100 100 102 101Chloromethane

014 U 100 100 104 105Vinyl chloride

018 U 100 100 107 105Bromomethane

040 U 100 100 121 121F F12-Dibromo-3-Chloropropane

021 U 100 100 107 11112-Dichlorobenzene

015 U 100 100 121 997Trichlorofluoromethane

0090 U 100 100 108 11911-Dichloroethene

0090 U 100 100 111 11012-Dichloropropane

0080 U 100 100 102 111112-Trichloro-122-trifluoroethane

27 U 100 100 986 101Acetone

013 U 100 100 113 119Carbon disulfide

034 U 100 100 100 101Methyl acetate

018 U 100 100 106 106Methylene Chloride

013 U 100 100 106 108trans-12-Dichloroethene

020 U 100 100 116 118Chlorodibromomethane

020 J 100 100 114 116 FMethyl tert-butyl ether

017 U 100 100 116 105Chloroethane

013 U 100 100 104 11111-Dichloroethane

018 U 100 100 105 109cis-12-Dichloroethene

23 U 100 100 111 1142-Butanone (MEK)

0080 U 100 100 108 113Chloroform

010 U 100 100 107 111Ethylbenzene

016 U 100 100 108 117Cyclohexane

0060 U 100 100 105 110Carbon tetrachloride

0080 U 100 100 106 114Benzene

019 U 100 100 107 10912-Dichloroethane

0090 U 100 100 107 113Trichloroethene

014 U 100 100 115 121Methylcyclohexane

012 U 100 100 113 116Dichlorobromomethane

018 U 100 100 109 115cis-13-Dichloropropene

099 U 100 100 111 1144-Methyl-2-pentanone (MIBK)

015 U 100 100 106 111Toluene

024 U 100 100 113 119 Ftrans-13-Dichloropropene

019 U 100 100 112 116112-Trichloroethane

010 U 100 100 110 116Tetrachloroethene

050 U 100 100 109 1112-Hexanone

028 U 100 100 116 11712-Dibromoethane

011 U 100 100 107 111Chlorobenzene

036 U 300 300 318 329Xylenes Total

012 U 100 100 107 110Styrene

019 U 100 100 115 114Bromoform

TestAmerica Edison 10162012Page 30 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10122012 0027 10122012 0051

Dilution Dilution50 50

Client Matrix Client Matrix Water

Method 8260B

Preparation 5030B

Units ugL460-45537-2 460-45537-2MS Lab Sample ID MSD Lab Sample ID

Matrix Spike

Matrix Spike Duplicate Recovery Report - Batch 460-131656

Analysis Date

Prep Date

Leach Date

10122012 0027

NA

Analysis Date

Prep Date

Leach Date

10122012 0051

NA

Amount

Sample

Analyte ResultQual Amount ResultQual ResultQual

MS MSDMS Spike MSD Spike

0080 U 100 100 107 111Isopropylbenzene

016 U 100 100 115 1161122-Tetrachloroethane

014 U 100 100 106 11013-Dichlorobenzene

023 U 100 100 106 11014-Dichlorobenzene

034 U 100 100 110 119124-Trichlorobenzene

TestAmerica Edison 10162012Page 31 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

WaterClient Matrix

10Dilution

Lab Sample ID

Method Blank - Batch 460-130997

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

vr479496d

1000 mL

5 mLUnits ugL

Method 8082

Preparation 3510C

PESTGC9MB 460-1309971-A

Analysis Date 10082012 2208

Analysis Batch

Prep Batch

Leach Batch NA

460-131137

460-130997

Prep Date Injection Volume

Leach Date

10082012 0755

NA PRIMARYColumn ID

Analyte RLMDLQualResult

013 U 050013PCB-1016

028 U 050028PCB-1221

012 U 050012PCB-1232

012 U 050012PCB-1242

024 U 050024PCB-1248

017 U 050017PCB-1254

015 U 050015PCB-1260

Surrogate Rec Acceptance Limits

DCB Decachlorobiphenyl 97 37 - 150

Surrogate Rec Acceptance Limits

DCB Decachlorobiphenyl 88 37 - 150

TestAmerica Edison 10162012Page 32 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Dilution

Dilution

Lab Control Sample

Lab Control Sample Duplicate Recovery Report - Batch 460-130997

10

10

Water

LCS Lab Sample ID

LCSD Lab Sample ID

Client Matrix

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

Client Matrix Water

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

ugL

vf479497d

1000 mL

5 mL

PRIMARY

vf479498d

1000 mL

5 mL

PRIMARY

ugL

Method 8082

Preparation 3510C

PESTGC9

PESTGC9

LCS 460-1309972-A

LCSD 460-1309973-A

Analysis Date

Prep Date

Leach Date

10082012 2224

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

Rec

103101 71 - 126 2 30PCB-1016

119115 73 - 130 4 30PCB-1260

Surrogate LCS Rec LCSD Rec Acceptance Limits

DCB Decachlorobiphenyl 91 108 37 - 150

Dilution

Dilution

Lab Control Sample

Lab Control Sample Duplicate Recovery Report - Batch 460-130997

10

10

Water

LCS Lab Sample ID

LCSD Lab Sample ID

Client Matrix

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

Client Matrix Water

Units

Instrument ID

Lab File ID

Initial WeightVolume

Final WeightVolume

Injection Volume

Column ID

ugL

vr479497d

1000 mL

5 mL

SECONDARY

vr479498d

1000 mL

5 mL

SECONDARY

ugL

Method 8082

Preparation 3510C

PESTGC9

PESTGC9

LCS 460-1309972-A

LCSD 460-1309973-A

Analysis Date

Prep Date

Leach Date

10082012 2224

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NA

Analysis Batch

Prep Batch

Leach Batch

460-131137

460-130997

NA

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

Rec

9997 71 - 126 3 30PCB-1016

117111 73 - 130 5 30PCB-1260

Surrogate LCS Rec LCSD Rec Acceptance Limits

DCB Decachlorobiphenyl 84 99 37 - 150

TestAmerica Edison 10162012Page 33 of 323

Quality Control Results

Job Number 460-45537-1Client Conestoga-Rovers amp Associates Inc

Water

10082012 2224

Dilution Dilution10 10

Client Matrix

LCSD Lab Sample ID

Client Matrix Water

Laboratory Control

Laboratory Duplicate Data Report - Batch 460-130997

Method 8082

Preparation 3510C

Units ugLLCS 460-1309972-A LCSD 460-1309973-ALCS Lab Sample ID

Analysis Date

Prep Date

Leach Date

10082012 0755

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NANA

LCSD

ResultQual

LCS

ResultQual

LCSD Spike

Amount

LCS Spike

AmountAnalyte

516507500 500PCB-1016

595573500 500PCB-1260

Water

10082012 2224

Dilution Dilution10 10

Client Matrix

LCSD Lab Sample ID

Client Matrix Water

Laboratory Control

Laboratory Duplicate Data Report - Batch 460-130997

Method 8082

Preparation 3510C

Units ugLLCS 460-1309972-A LCSD 460-1309973-ALCS Lab Sample ID

Analysis Date

Prep Date

Leach Date

10082012 0755

Analysis Date

Prep Date

Leach Date

10082012 2239

10082012 0755

NANA

LCSD

ResultQual

LCS

ResultQual

LCSD Spike

Amount

LCS Spike

AmountAnalyte

497483500 500PCB-1016

583557500 500PCB-1260

TestAmerica Edison 10162012Page 34 of 323

DATA REPORTING QUALIFIERS

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Lab Section Qualifier Description

GCMS VOA

Indicates the analyte was analyzed for but not detectedU

MSMSD Recovery or RPD exceeds the control limitsF

Result is less than the RL but greater than or equal to the MDL and the

concentration is an approximate value

J

GC Semi VOA

Indicates the analyte was analyzed for but not detectedU

TestAmerica Edison 10162012Page 35 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

QC Association Summary

Lab Sample ID Client Sample ID Client Matrix Method Prep Batch

Report

Basis

GCMS VOA

Analysis Batch460-131656

Lab Control Sample Water 8260BLCS 460-1316563 T

Method Blank Water 8260BMB 460-1316564 T

WaterWC-17338-100512-MW14-MM-251 8260B460-45537-1 T

WaterWC-17338-100512-MW101-MM-252 8260B460-45537-2 T

Matrix Spike Water 8260B460-45537-2MS T

Matrix Spike Duplicate Water 8260B460-45537-2MSD T

WaterTB-17338-100512-253 8260B460-45537-3TB T

Report Basis

T = Total

GC Semi VOA

Prep Batch 460-130997

Lab Control Sample Water 3510CLCS 460-1309972-A T

Lab Control Sample Duplicate Water 3510CLCSD 460-1309973-A T

Method Blank Water 3510CMB 460-1309971-A T

WaterWC-17338-100512-MW14-MM-251 3510C460-45537-1 T

WaterWC-17338-100512-MW101-MM-252 3510C460-45537-2 T

Analysis Batch460-131137

Lab Control Sample Water 460-1309978082LCS 460-1309972-A T

Lab Control Sample Duplicate Water 460-1309978082LCSD 460-1309973-A T

Method Blank Water 460-1309978082MB 460-1309971-A T

Water 460-130997WC-17338-100512-MW14-MM-251 8082460-45537-1 T

Water 460-130997WC-17338-100512-MW101-MM-252 8082460-45537-2 T

Report Basis

T = Total

TestAmerica Edison

10162012Page 36 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Laboratory Chronicle

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1000

460-45537-1 WC-17338-100512-MW14-MM-251

P5030B 460-45537-A-1 460-131656 10112012 2341 KBTAL EDI1

A8260B 460-45537-A-1 460-131656 10112012 2341 KBTAL EDI1

P3510C 460-45537-E-1-B 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 460-45537-E-1-B 460-131137 460-130997 10092012 0029 CBBTAL EDI1

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 WC-17338-100512-MW101-MM-252

P5030B 460-45537-A-2 460-131656 10122012 0004 KBTAL EDI1

A8260B 460-45537-A-2 460-131656 10122012 0004 KBTAL EDI1

P3510C 460-45537-E-2-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 460-45537-E-2-A 460-131137 460-130997 10092012 0045 CBBTAL EDI1

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 MS WC-17338-100512-MW101-MM-252

P5030B 460-45537-C-2 MS 460-131656 10122012 0027 KBTAL EDI5

A8260B 460-45537-C-2 MS 460-131656 10122012 0027 KBTAL EDI5

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 1230

460-45537-2 MSD WC-17338-100512-MW101-MM-252

P5030B 460-45537-C-2 MSD 460-131656 10122012 0051 KBTAL EDI5

A8260B 460-45537-C-2 MSD 460-131656 10122012 0051 KBTAL EDI5

10052012 1910

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime Received DateTime10052012 0000

460-45537-3 TB-17338-100512-253

P5030B 460-45537-A-3 460-131656 10112012 2317 KBTAL EDI1

A8260B 460-45537-A-3 460-131656 10112012 2317 KBTAL EDI1

A = Analytical Method P = Prep Method TestAmerica Edison

10162012Page 37 of 323

Quality Control Results

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Laboratory Chronicle

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

MB NA

P5030B MB 460-1316564 460-131656 10112012 2247 KBTAL EDI1

A8260B MB 460-1316564 460-131656 10112012 2247 KBTAL EDI1

P3510C MB 460-1309971-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 MB 460-1309971-A 460-131137 460-130997 10082012 2208 CBBTAL EDI1

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

LCS NA

P5030B LCS 460-1316563 460-131656 10112012 2113 KBTAL EDI1

A8260B LCS 460-1316563 460-131656 10112012 2113 KBTAL EDI1

P3510C LCS 460-1309972-A 460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 LCS 460-1309972-A 460-131137 460-130997 10082012 2224 CBBTAL EDI1

Lab ID

Method Bottle ID Run

Analysis

Batch Prep Batch

Date Prepared

Analyzed Dil Lab Analyst

Client ID

Sample DateTime NA Received DateTime NA

LCSD NA

P3510C LCSD

460-1309973-A

460-131137 460-130997 10082012 0755 HWTAL EDI1

A8082 LCSD

460-1309973-A

460-131137 460-130997 10082012 2239 CBBTAL EDI1

Lab ReferencesTAL EDI = TestAmerica Edison

A = Analytical Method P = Prep Method TestAmerica Edison

10162012Page 38 of 323

Method 8260 DELVolatile Organics (GCMS) by Method

8260 (Delaware)

10162012Page 39 of 323

FORM II

GCMS VOA SURROGATE RECOVERY

Lab Name Job No 460-45537-1

SDG No

Matrix Water Level Low

TestAmerica Edison

GC Column (1) Rtx-VMS ID 018(mm)

Lab Sample IDClient Sample ID DCA TOL BFB

460-45537-1WC-17338-100512-MW14-MM-251

97 96 99

460-45537-2WC-17338-100512-MW101-MM-252

97 97 98

460-45537-3TB-17338-100512-253

97 97 99

MB 460-1316564 99 96 95

LCS 460-1316563 96 99 97

460-45537-2 MSWC-17338-100512-MW101-MM-252 MS

96 99 99

460-45537-2 MSDWC-17338-100512-MW101-MM-252 MSD

96 99 97

QC LIMITSQC LIMITSDCA = 12-Dichloroethane-d4 (Surr) 70-130

TOL = Toluene-d8 (Surr) 70-130

BFB = 4-Bromofluorobenzene 70-130

FORM II 8260B

Column to be used to flag recovery values

10162012Page 40 of 323

GCMS VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08977dWater

Lab ID LCS 460-1316563 Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

111-Trichloroethane 200 210 74-128105

Dichlorodifluoromethane 200 181 46-14590

Chloromethane 200 210 58-146105

Vinyl chloride 200 203 61-144101

Bromomethane 200 211 55-153105

12-Dibromo-3-Chloropropane 200 222 70-116111

12-Dichlorobenzene 200 209 82-122104

Trichlorofluoromethane 200 190 69-14795

11-Dichloroethene 200 223 56-139112

12-Dichloropropane 200 211 80-120106

112-Trichloro-122-trifluoroethane

200 203 47-139102

Acetone 200 250 45-156125

Carbon disulfide 200 218 58-139109

Methyl acetate 200 220 50-151110

Methylene Chloride 200 200 79-119100

trans-12-Dichloroethene 200 216 75-122108

Chlorodibromomethane 200 217 80-120109

Methyl tert-butyl ether 200 207 71-115104

Chloroethane 200 201 69-145101

11-Dichloroethane 200 204 78-122102

cis-12-Dichloroethene 200 211 80-120106

2-Butanone (MEK) 200 214 65-114107

Chloroform 200 205 82-123103

Ethylbenzene 200 206 79-126103

Cyclohexane 200 208 58-133104

Carbon tetrachloride 200 211 73-120105

Benzene 200 212 83-124106

12-Dichloroethane 200 204 74-118102

Trichloroethene 200 212 78-119106

Methylcyclohexane 200 215 61-129107

Dichlorobromomethane 200 214 79-119107

cis-13-Dichloropropene 200 216 80-120108

4-Methyl-2-pentanone (MIBK) 200 214 53-120107

Toluene 200 205 80-120103

trans-13-Dichloropropene 200 215 78-118108

112-Trichloroethane 200 217 79-119109

Tetrachloroethene 200 210 68-139105

2-Hexanone 200 201 53-121100

12-Dibromoethane 200 215 78-118107

Chlorobenzene 200 206 81-121103

Xylenes Total 600 612 76-121102

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 41 of 323

GCMS VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08977dWater

Lab ID LCS 460-1316563 Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

Styrene 200 207 69-112104

Bromoform 200 217 73-123109

Isopropylbenzene 200 207 80-125104

1122-Tetrachloroethane 200 210 74-126105

13-Dichlorobenzene 200 204 81-126102

14-Dichlorobenzene 200 204 83-123102

124-Trichlorobenzene 200 220 66-120110

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 42 of 323

GCMS VOA MATRIX SPIKE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08985dWater

Lab ID 460-45537-2 MS Client ID WC-17338-100512-MW101-MM-252 MS

TestAmerica Edison

LIMITS

COMPOUND

CONCENTRATION

REC

QC

REC

SAMPLE

CONCENTRATION

SPIKE

ADDED

(ugL) (ugL) (ugL)

MS MS

100 103 74-128111-Trichloroethane 1030060 U

100 865 46-145Dichlorodifluoromethane 87022 U

100 102 58-146Chloromethane 102010 U

100 104 61-144Vinyl chloride 104014 U

100 107 55-153Bromomethane 107018 U

100 121 70-11612-Dibromo-3-Chloropropane 121040 U F

100 107 82-12212-Dichlorobenzene 107021 U

100 121 69-147Trichlorofluoromethane 121015 U

100 108 56-13911-Dichloroethene 1080090 U

100 111 80-12012-Dichloropropane 1110090 U

100 102 47-139112-Trichloro-122-trifluoroethane

1020080 U

100 986 45-156Acetone 9927 U

100 113 58-139Carbon disulfide 113013 U

100 100 50-151Methyl acetate 100034 U

100 106 79-119Methylene Chloride 106018 U

100 106 75-122trans-12-Dichloroethene 106013 U

100 116 80-120Chlorodibromomethane 116020 U

100 114 71-115Methyl tert-butyl ether 114020 J

100 116 69-145Chloroethane 116017 U

100 104 78-12211-Dichloroethane 104013 U

100 105 80-120cis-12-Dichloroethene 105018 U

100 111 65-1142-Butanone (MEK) 11123 U

100 108 82-123Chloroform 1080080 U

100 107 79-126Ethylbenzene 107010 U

100 108 58-133Cyclohexane 108016 U

100 105 73-120Carbon tetrachloride 1050060 U

100 106 83-124Benzene 1060080 U

100 107 74-11812-Dichloroethane 107019 U

100 107 78-119Trichloroethene 1070090 U

100 115 61-129Methylcyclohexane 115014 U

100 113 79-119Dichlorobromomethane 113012 U

100 109 80-120cis-13-Dichloropropene 109018 U

100 111 53-1204-Methyl-2-pentanone (MIBK) 111099 U

100 106 80-120Toluene 106015 U

100 113 78-118trans-13-Dichloropropene 113024 U

100 112 79-119112-Trichloroethane 112019 U

100 110 68-139Tetrachloroethene 110010 U

100 109 53-1212-Hexanone 109050 U

100 116 78-11812-Dibromoethane 116028 U

100 107 81-121Chlorobenzene 107011 U

300 318 76-121Xylenes Total 106036 U

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 43 of 323

GCMS VOA MATRIX SPIKE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08985dWater

Lab ID 460-45537-2 MS Client ID WC-17338-100512-MW101-MM-252 MS

TestAmerica Edison

LIMITS

COMPOUND

CONCENTRATION

REC

QC

REC

SAMPLE

CONCENTRATION

SPIKE

ADDED

(ugL) (ugL) (ugL)

MS MS

100 107 69-112Styrene 107012 U

100 115 73-123Bromoform 115019 U

100 107 80-125Isopropylbenzene 1070080 U

100 115 74-1261122-Tetrachloroethane 115016 U

100 106 81-12613-Dichlorobenzene 106014 U

100 106 83-12314-Dichlorobenzene 106023 U

100 110 66-120124-Trichlorobenzene 110034 U

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 44 of 323

GCMS VOA MATRIX SPIKE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08986dWater

Lab ID 460-45537-2 MSD Client ID WC-17338-100512-MW101-MM-252

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

MSD MSD

100 106 30 74-128111-Trichloroethane 3106

100 896 30 46-145Dichlorodifluoromethane 490

100 101 30 58-146Chloromethane 0101

100 105 30 61-144Vinyl chloride 0105

100 105 30 55-153Bromomethane 2105

100 121 30 70-11612-Dibromo-3-Chloropropane 0121 F

100 111 30 82-12212-Dichlorobenzene 3111

100 997 30 69-147Trichlorofluoromethane 19100

100 119 30 56-13911-Dichloroethene 9119

100 110 30 80-12012-Dichloropropane 0110

100 111 30 47-139112-Trichloro-122-trifluoroethane

8111

100 101 30 45-156Acetone 2101

100 119 30 58-139Carbon disulfide 5119

100 101 30 50-151Methyl acetate 1101

100 106 30 79-119Methylene Chloride 0106

100 108 30 75-122trans-12-Dichloroethene 2108

100 118 30 80-120Chlorodibromomethane 2118

100 116 30 71-115Methyl tert-butyl ether 1116 F

100 105 30 69-145Chloroethane 10105

100 111 30 78-12211-Dichloroethane 7111

100 109 30 80-120cis-12-Dichloroethene 4109

100 114 30 65-1142-Butanone (MEK) 3114

100 113 30 82-123Chloroform 4113

100 111 30 79-126Ethylbenzene 3111

100 117 30 58-133Cyclohexane 7117

100 110 30 73-120Carbon tetrachloride 5110

100 114 30 83-124Benzene 7114

100 109 30 74-11812-Dichloroethane 2109

100 113 30 78-119Trichloroethene 5113

100 121 30 61-129Methylcyclohexane 5121

100 116 30 79-119Dichlorobromomethane 3116

100 115 30 80-120cis-13-Dichloropropene 5115

100 114 30 53-1204-Methyl-2-pentanone (MIBK) 3114

100 111 30 80-120Toluene 5111

100 119 30 78-118trans-13-Dichloropropene 5119 F

100 116 30 79-119112-Trichloroethane 3116

100 116 30 68-139Tetrachloroethene 5116

100 111 30 53-1212-Hexanone 2111

100 117 30 78-11812-Dibromoethane 1117

100 111 30 81-121Chlorobenzene 3111

300 329 30 76-121Xylenes Total 3110

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 45 of 323

GCMS VOA MATRIX SPIKE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID e08986dWater

Lab ID 460-45537-2 MSD Client ID WC-17338-100512-MW101-MM-252

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

MSD MSD

100 110 30 69-112Styrene 3110

100 114 30 73-123Bromoform 1114

100 111 30 80-125Isopropylbenzene 4111

100 116 30 74-1261122-Tetrachloroethane 0116

100 110 30 81-12613-Dichlorobenzene 4110

100 110 30 83-12314-Dichlorobenzene 4110

100 119 30 66-120124-Trichlorobenzene 8119

FORM III 8260B

Column to be used to flag recovery and RPD values

10162012Page 46 of 323

FORM IV

GCMS VOA METHOD BLANK SUMMARY

Lab Name

SDG No

Job No 460-45537-1TestAmerica Edison

Date Analyzed

GC Column ID

Instrument ID 10112012 2247

Rtx-VMS

NHeated Purge(YN)

VOAMS5

e08981dLab File ID Lab Sample ID MB 460-1316564

WaterMatrix

018(mm)

THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES

LAB SAMPLE ID

LAB

FILE ID DATE ANALYZEDCLIENT SAMPLE ID

10112012 2113e08977dLCS 460-1316563

10112012 2317e08982d460-45537-3TB-17338-100512-253

10112012 2341e08983d460-45537-1WC-17338-100512-MW14-MM-251

10122012 0004e08984d460-45537-2WC-17338-100512-MW101-MM-252

10122012 0027e08985d460-45537-2 MSWC-17338-100512-MW101-MM-252 MS

10122012 0051e08986d460-45537-2 MSDWC-17338-100512-MW101-MM-252 MSD

FORM IV 8260B

10162012Page 47 of 323

FORM V

BROMOFLUOROBENZENE (BFB)

Lab Name

SDG No

Job No 460-45537-1

Lab File ID

Instrument ID

e07834d

VOAMS5

09172012

0324

BFB Injection Date

BFB Injection Time

ME ION ABUNDANCE CRITERIA RELATIVEABUNDANCE

Analysis Batch No 128076

50 150 - 400 of mass 95 219

75 300 - 600 of mass 95 525

95 Base Peak 100 relative abundance 1000

96 50 - 90 of mass 95 64

173 Less than 20 of mass 174 00 (00)1

174 500 - 12000 of mass 95 796

175 50 - 90 of mass 174 66 (83)1

176 950 - 1010 of mass 174 761 (957)1

177 50 - 90 of mass 176 48 (63)2

1-Value is mass 174 2-Value is mass 176

THIS CHECK APPLIES TO THE FOLLOWING SAMPLES MS MSD BLANKS AND STANDARDS

GCMS VOA INSTRUMENT PERFORMANCE CHECK

TestAmerica Edison

CLIENT SAMPLE IDLAB

FILE IDLAB SAMPLE IDDATE

ANALYZEDTIME

ANALYZED

e07836d 09172012 0449IC 460-1280762

e07838d 09172012 0536IC 460-1280763

e07839d 09172012 0600ICIS 460-1280764

e07840d 09172012 0623IC 460-1280765

e07841d 09172012 0646IC 460-1280766

e07842d 09172012 0710IC 460-1280767

FORM V 8260B 10162012Page 48 of 323

FORM V

BROMOFLUOROBENZENE (BFB)

Lab Name

SDG No

Job No 460-45537-1

Lab File ID

Instrument ID

e08975d

VOAMS5

10112012

2008

BFB Injection Date

BFB Injection Time

ME ION ABUNDANCE CRITERIA RELATIVEABUNDANCE

Analysis Batch No 131656

50 150 - 400 of mass 95 218

75 300 - 600 of mass 95 518

95 Base Peak 100 relative abundance 1000

96 50 - 90 of mass 95 65

173 Less than 20 of mass 174 07 (07)1

174 500 - 12000 of mass 95 896

175 50 - 90 of mass 174 72 (80)1

176 950 - 1010 of mass 174 872 (973)1

177 50 - 90 of mass 176 53 (61)2

1-Value is mass 174 2-Value is mass 176

THIS CHECK APPLIES TO THE FOLLOWING SAMPLES MS MSD BLANKS AND STANDARDS

GCMS VOA INSTRUMENT PERFORMANCE CHECK

TestAmerica Edison

CLIENT SAMPLE IDLAB

FILE IDLAB SAMPLE IDDATE

ANALYZEDTIME

ANALYZED

e08976d 10112012 2050CCVIS 460-1316562

e08977d 10112012 2113LCS 460-1316563

e08981d 10112012 2247MB 460-1316564

TB-17338-100512-253 e08982d 10112012 2317460-45537-3

WC-17338-100512-MW14-MM-251

e08983d 10112012 2341460-45537-1

WC-17338-100512-MW101-MM-252

e08984d 10122012 0004460-45537-2

WC-17338-100512-MW101-MM-252 MS

e08985d 10122012 0027460-45537-2 MS

WC-17338-100512-MW101-MM-252 MSD

e08986d 10122012 0051460-45537-2 MSD

e08987d 10122012 0114CCV 460-13165610

FORM V 8260B 10162012Page 49 of 323

GCMS VOA INTERNAL STANDARD AREA AND RETENTION TIME SUMMARY

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVIS 460-1316562 Date Analyzed 10112012 2050

Lab File ID (Standard) e08976d

Instrument ID VOAMS5 GC Column Rtx-VMS ID 018(mm)

Heated Purge (YN) N

Calibration ID 17515

AREA RT AREA RT AREA RT

FB CBZ DCB

UPPER LIMIT

LOWER LIMIT

2625312

656328 578671

2314682

333917

1335668

360 695 10471224 HOUR STD

410

310

745

645

1097

997

1312656 1157341 667834

LAB SAMPLE ID CLIENT SAMPLE ID

LCS 460-1316563 1318918 1146590 683882 360 695 1047

MB 460-1316564 1238441 1084553 638826 360 695 1047

460-45537-3 TB-17338-100512-253 1280000 1135339 646856 359 695 1047

460-45537-1 WC-17338-100512-MW14-MM-251

1242225 1119807 641810 359 695 1047

460-45537-2 WC-17338-100512-MW101-MM-252

1247617 1105330 633816 360 695 1047

460-45537-2 MS WC-17338-100512-MW101-MM-252 MS

1234975 1102789 642491 359 695 1047

460-45537-2 MSD WC-17338-100512-MW101-MM-252 MSD

1296388 1119645 654839 360 695 1047

CCV 460-13165610 1274024 1125053 665092 359 695 1047

FB = Fluorobenzene

CBZ = Chlorobenzene-d5

DCB = 14-Dichlorobenzene-d4

Area Limit = 50-200 of internal standard area

RT Limit = plusmn 05 minutes of internal standard RT

Column used to flag values outside QC limits

FORM VIII 8260B

10162012Page 50 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014J1634-04-4 Methyl tert-butyl ether 017

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015J108-88-3 Toluene 017

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 51 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010J127-18-4 Tetrachloroethene 028

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

96 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 52 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix e08983dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2341

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 53 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08983d Report Date 12-Oct-2012 0041

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08983dLab Smp Id 460-45537-A-1 Client Smp ID WC-17338-100512-MW1Inj Date 11-OCT-2012 2341 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-1Misc Info 460-45537-A-1Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 8 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

28 MTBE 73 2016 2022 (0561) 2797 016909 017(a)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 375883 486598 49

52 Fluorobenzene 96 3595 3601 (1000) 1242225 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1240232 479413 48

66 Toluene 91 5162 5162 (0742) 4639 017041 017(a)

71 Tetrachloroethene 166 5582 5582 (0803) 1902 028047 028(a)

78 Chlorobenzene-d5 117 6954 6954 (1000) 1119807 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 516081 495668 50

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 641810 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 54 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

10162012Page 55 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

28 MTBE

10162012Page 56 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

66 Toluene

10162012Page 57 of 323

Data File e08983d

Date 11-OCT-2012 2341

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-1 Operator GCMS VOAMS5

71 Tetrachloroethene

10162012Page 58 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014J1634-04-4 Methyl tert-butyl ether 020

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 59 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

98 70-130460-00-4 4-Bromofluorobenzene

97 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 60 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix e08984dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0004

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 61 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08984d Report Date 12-Oct-2012 1126

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08984dLab Smp Id 460-45537-A-2 Client Smp ID WC-17338-100512-MW1Inj Date 12-OCT-2012 0004 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-2Misc Info 460-45537-A-2Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 9 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

28 MTBE 73 2016 2022 (0561) 3378 020333 020(a)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 375158 483561 48

52 Fluorobenzene 96 3595 3601 (1000) 1247617 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1243750 487069 49

78 Chlorobenzene-d5 117 6954 6954 (1000) 1105330 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 506189 492299 49

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 633816 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 62 of 323

Data File e08984d

Date 12-OCT-2012 0004

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-2 Operator GCMS VOAMS5

10162012Page 63 of 323

Data File e08984d

Date 12-OCT-2012 0004

Client ID WC-17338-100512-MW1 Instrument VOAMS5i

Sample Info 460-45537-A-2 Operator GCMS VOAMS5

28 MTBE

10162012Page 64 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018J75-09-2 Methylene Chloride 074

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014U1634-04-4 Methyl tert-butyl ether 014

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080J67-66-3 Chloroform 0096

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 65 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

97 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

97 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 66 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

TB-17338-100512-253

SDG No

460-45537-1

Lab Sample ID 460-45537-3

Matrix e08982dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 0000

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2317

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 67 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08982d Report Date 12-Oct-2012 1126

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08982dLab Smp Id 460-45537-A-3 Client Smp ID TB-17338-100512-253Inj Date 11-OCT-2012 2317 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-A-3Misc Info 460-45537-A-3Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 7 Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

22 Methylene Chloride 49 1864 1864 (0518) 6426 073512 074(a)

42 Chloroform 83 2839 2845 (0790) 973 009557 0096(aH)

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 385354 484137 48

52 Fluorobenzene 96 3595 3601 (1000) 1280000 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1266759 482968 48

78 Chlorobenzene-d5 117 6954 6954 (1000) 1135339 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 518232 493851 49

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 646856 500000

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

H - Operator selected an alternate compound hit

10162012Page 68 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

10162012Page 69 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

22 Methylene Chloride

10162012Page 70 of 323

Data File e08982d

Date 11-OCT-2012 2317

Client ID TB-17338-100512-253 Instrument VOAMS5i

Sample Info 460-45537-A-3 Operator GCMS VOAMS5

42 Chloroform

10162012Page 71 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1280762 e07836d2Level IC 460-1280763 e07838d3Level ICIS 460-1280764 e07839d4Level IC 460-1280765 e07840d5Level IC 460-1280766 e07841d6Level IC 460-1280767 e07842d

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

Dichlorodifluoromethane 01877 01710 01761 01874 01774 Ave 6501572

01000 30001761

Chloromethane 04585 03624 03717 03896 03503 Ave 13403074

01000 30003733

Vinyl chloride 03440 02904 02965 03157 02914 Ave 10102532

01000 30002985

Bromomethane 01457 01433 01250 01279 01268 Ave 8301184

01000 30001312

Chloroethane 01177 01273 01133 01184 00992 Ave 14300838

01000 30001099

Trichlorofluoromethane 02861 02160 02403 02359 02461 Ave 9902285

01000 30002422

11-Dichloroethene 01607 01355 01549 01479 01528 Ave 5801456

01000 30001496

Carbon disulfide 07031 06470 06825 07347 07283 Ave 5906366

01000 30006887

112-Trichloro-122-trifluoroethane 01346 01631 01661 01849 01887 Ave 11601772

01000 30001691

Methylene Chloride 04479 03769 03581 03500 03182 Ave 14802947

01000 30003576

Acetone 00225 00193 00188 00182 00162 Ave 13800153

01000 30000184

trans-12-Dichloroethene 02047 01989 02141 02174 02016 Ave 4301946

01000 30002052

Methyl acetate 00482 00463 00420 00421 00402 Ave 9400371

01000 30000426

Methyl tert-butyl ether 07109 07281 06924 06817 06907 Ave 6505992

01000 30006838

11-Dichloroethane 04650 04524 04893 04673 04494 Ave 4604257

01000 30004582

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 72 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

cis-12-Dichloroethene 02536 02396 02453 02363 02237 Ave 5602184

01000 30002361

Cyclohexane 03116 04199 04030 04447 04640 Ave 13204438

01000 30004145

Chloroform 03895 04109 04030 04060 03948 Ave 2503851

01000 30003982

Carbon tetrachloride 02420 02373 02793 02813 02930 Ave 9102903

01000 30002705

111-Trichloroethane 03091 03114 03513 03424 03583 Ave 6403522

01000 30003375

2-Butanone (MEK) 00273 00279 00385 00372 00372 Ave 14900364

01000 30000341

Benzene 12012 12533 12592 12117 12284 Ave 8709836

01000 30011896

12-Dichloroethane 03398 03425 03293 03270 03193 Ave 3503124

01000 30003284

Methylcyclohexane 02272 03440 03287 03727 03690 Ave 16303532

01000 30003325

Trichloroethene 02571 02192 02414 02341 02365 Ave 5202426

01000 30002385

12-Dichloropropane 02758 02786 02804 02730 02724 Ave 1202733

01000 30002756

Dichlorobromomethane 03209 03160 03185 03141 03239 Ave 1303237

01000 30003195

cis-13-Dichloropropene 05043 05293 05370 05217 05393 Ave 3105530

01000 30005308

Toluene 13662 13454 14250 13844 13425 Ave 9510731

01000 30013228

Tetrachloroethene 02730 02844 03369 03253 03225 Ave 8303255

01000 30003113

4-Methyl-2-pentanone (MIBK) 03587 03603 03526 03550 03603 Ave 1603692

01000 30003593

trans-13-Dichloropropene 04563 04743 04806 04779 04910 Ave 3805114

01000 30004819

112-Trichloroethane 02303 02327 02287 02201 02185 Ave 2502280

01000 30002264

Chlorodibromomethane 03013 02986 03088 03052 03111 Ave 3003249

01000 30003083

12-Dibromoethane 02596 02708 02743 02671 02629 Ave 2002676

01000 30002670

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 73 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

018(mm)Rtx-VMS ID

INTERNAL STANDARD CURVE EVALUATION

ANALYTE RRF

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CURVETYPE

COEFFICIENT

B M1 M2

RSD MAXRSD

R^2OR COD

MIN R^2OR COD

MIN RRF

LVL 6

2-Hexanone 02652 02737 02670 02679 02755 Ave 3202514

01000 30002668

Chlorobenzene 08958 08985 09292 09070 08727 Ave 4008261

01000 30008882

Ethylbenzene 04549 04523 04953 04866 04834 Ave 3704808

01000 30004756

m-Xylene amp p-Xylene 05967 05752 06297 06168 06094 Ave 6505224

01000 30005917

o-Xylene 05732 05675 06142 06014 05989 Ave 3205765

01000 30005886

Bromoform 02053 01991 02150 02194 02258 Ave 4902237

01000 30002147

Styrene 09657 09899 10525 10511 10477 Ave 6408917

01000 30009998

Isopropylbenzene 13314 13509 15606 15346 15340 Ave 10811764

01000 30014146

1122-Tetrachloroethane 06545 06405 06616 06489 06390 Ave 1706330

01000 30006462

13-Dichlorobenzene 12616 12687 13292 13133 12758 Ave 3012242

01000 30012788

14-Dichlorobenzene 13636 13114 13708 13534 13010 Ave 3412550

01000 30013259

12-Dichlorobenzene 12298 12143 12601 12232 11746 Ave 3211521

01000 30012090

12-Dibromo-3-Chloropropane 01290 01163 01082 01109 01042 Ave 7801095

01000 30001130

124-Trichlorobenzene 06538 06139 06311 06265 05725 Ave 5405732

01000 30006118

12-Dichloroethane-d4 (Surr) 02599 02736 02573 02553 02667 Ave 2802702

01000 30002638

Toluene-d8 (Surr) 11377 12027 11720 11573 11645 Ave 1811690

01000 30011672

4-Bromofluorobenzene 07799 08146 08086 08044 08193 Ave 1908206

01000 30008079

FORM VI 8260B

Note The m1 coefficient is the same as Ave RRF for an Ave curve type

10162012Page 74 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1280762 e07836dLevel 2 IC 460-1280763 e07838dLevel 3 ICIS 460-1280764 e07839dLevel 4 IC 460-1280765 e07840dLevel 5 IC 460-1280766 e07841dLevel 6 IC 460-1280767 e07842d

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Dichlorodifluoromethane AveFB 8660 39416 167418 450014 17982634551928

100 500 200 500 200500

Chloromethane AveFB 21155 83523 353287 935453 35519068902969

100 500 200 500 200500

Vinyl chloride AveFB 15876 66919 281874 757876 29543837332518

100 500 200 500 200500

Bromomethane AveFB 6723 33032 118799 307121 12855673429373

100 500 200 500 200500

Chloroethane AveFB 5433 29332 107678 284219 10059762426216

100 500 200 500 200500

Trichlorofluoromethane AveFB 13203 49780 228376 566305 24953266618134

100 500 200 500 200500

11-Dichloroethene AveFB 7415 31234 147259 355088 15491024214942

100 500 200 500 200500

Carbon disulfide AveFB 32446 149121 648801 1763903 738404918433408

100 500 200 500 200500

112-Trichloro-122-trifluoroethane

AveFB 6213 37580 157867 443949 19130255130629

100 500 200 500 200500

Methylene Chloride AveFB 20667 86862 340378 840419 32256318533685

100 500 200 500 200500

Acetone AveFB 5188 13342 17849 43750 164598441742

500 150 200 500 200500

trans-12-Dichloroethene AveFB 9445 45844 203500 521911 20443355633771

100 500 200 500 200500

Methyl acetate AveFB 2222 10660 39926 101112 4077131074355

100 500 200 500 200500

Methyl tert-butyl ether AveFB 32806 167790 658123 1636664 700252217351574

100 500 200 500 200500

11-Dichloroethane AveFB 21457 104265 465144 1121930 455634112326764

100 500 200 500 200500

cis-12-Dichloroethene AveFB 11702 55218 233129 567238 22679686324299

100 500 200 500 200500

FORM VI 8260B 10162012Page 75 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Cyclohexane AveFB 14380 96765 383104 1067735 470410312852489

100 500 200 500 200500

Chloroform AveFB 17974 94697 383084 974788 400250611152231

100 500 200 500 200500

Carbon tetrachloride AveFB 11168 54679 265527 675330 29705928405131

100 500 200 500 200500

111-Trichloroethane AveFB 14264 71766 333961 821993 363312510199723

100 500 200 500 200500

2-Butanone (MEK) AveFB 6291 19260 36552 89217 3773171055008

500 150 200 500 200500

Benzene AveCBZ 45050 227079 968083 2380099 986355721876514

100 500 200 500 200500

12-Dichloroethane AveFB 15679 78926 312991 785178 32368389046377

100 500 200 500 200500

Methylcyclohexane AveFB 10486 79279 312424 894738 374094710227785

100 500 200 500 200500

Trichloroethene AveFB 11865 50527 229465 562086 23978387026524

100 500 200 500 200500

12-Dichloropropane AveFB 12728 64209 266559 655380 27621167913672

100 500 200 500 200500

Dichlorobromomethane AveFB 14807 72835 302742 754124 32836079374106

100 500 200 500 200500

cis-13-Dichloropropene AveCBZ 18914 95905 412847 1024782 433022112299317

100 500 200 500 200500

Toluene AveCBZ 51238 243768 1095520 2719268 1077972123868197

100 500 200 500 200500

Tetrachloroethene AveCBZ 10238 51530 258990 639002 25895417239654

100 500 200 500 200500

4-Methyl-2-pentanone (MIBK) AveCBZ 67258 195851 271059 697282 28927468212153

500 150 200 500 200500

trans-13-Dichloropropene AveCBZ 17115 85943 369516 938808 394242511373599

100 500 200 500 200500

112-Trichloroethane AveCBZ 8636 42154 175853 432262 17543015071317

100 500 200 500 200500

Chlorodibromomethane AveCBZ 11301 54107 237421 599464 24982697227226

100 500 200 500 200500

12-Dibromoethane AveCBZ 9735 49066 210900 524614 21107665952425

100 500 200 500 200500

2-Hexanone AveCBZ 49729 148758 205286 526223 22117155590902

500 150 200 500 200500

Chlorobenzene AveCBZ 33596 162793 714336 1781568 700752018374405

100 500 200 500 200500

FORM VI 8260B 10162012Page 76 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GCMS VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

VOAMS5

Analy Batch No 128076

17515Calibration Start Date Calibration End Date09172012 0449

N

09172012 0710

GC Column Rtx-VMS ID 018(mm)

INTERNAL STANDARD RESPONSE AND CONCENTRATION

ANALYTE CURVETYPE

ISREF

RESPONSE

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5

CONCENTRATION (UGL)

LVL 1 LVL 2 LVL 3 LVL 4 LVL 5LVL 6 LVL 6

Ethylbenzene AveCBZ 17061 81955 380762 955894 388164310693410

100 500 200 500 200500

m-Xylene amp p-Xylene AveCBZ 44761 208423 968280 2423002 978688223238078

200 100 400 100 4001000

o-Xylene AveCBZ 21499 102832 472158 1181273 480921512821590

100 500 200 500 200500

Bromoform AveCBZ 7698 36074 165267 430943 18127954974461

100 500 200 500 200500

Styrene AveCBZ 36217 179367 809158 2064560 841264519831782

100 500 200 500 200500

Isopropylbenzene AveCBZ 49933 244766 1199765 3014281 1231710326165908

100 500 200 500 200500

1122-Tetrachloroethane AveDCB 13823 63947 277413 702309 28987687365342

100 500 200 500 200500

13-Dichlorobenzene AveDCB 26644 126663 557342 1421450 578731414243841

100 500 200 500 200500

14-Dichlorobenzene AveDCB 28798 130929 574816 1464915 590189114602396

100 500 200 500 200500

12-Dichlorobenzene AveDCB 25972 121236 528396 1324016 532862113405399

100 500 200 500 200500

12-Dibromo-3-Chloropropane AveDCB 2725 11615 45388 120062 4727441274610

100 500 200 500 200500

124-Trichlorobenzene AveDCB 13808 61295 264648 678119 25969596669727

100 500 200 500 200500

12-Dichloroethane-d4 (Surr) AveFB 599539 630441 611357 613057 676105782507

500 500 500 500 500500

Toluene-d8 (Surr) AveCBZ 2133452 2179204 2252606 2273339 23375152600040

500 500 500 500 500500

4-Bromofluorobenzene AveDCB 823604 813301 847619 870646 929176954872

500 500 500 500 500500

Curve Type LegendAve = Average ISTD

FORM VI 8260B 10162012Page 77 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07836d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07836dLab Smp Id IC-VMCAL1 Inj Date 17-SEP-2012 0449 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL1Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 2 Calibration Sample Level 1Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 8660 100000 11

3 Chloromethane 50 1004 1004 (0280) 21155 100000 12

4 Vinyl Chloride 62 1016 1016 (0283) 15876 100000 12

6 Bromomethane 94 1169 1169 (0326) 6723 100000 11

5 Chloroethane 64 1230 1230 (0343) 5433 100000 11

7 Trichlorofluoromethane 101 1291 1291 (0360) 13203 100000 12

14 Freon TF 101 1565 1565 (0436) 6213 100000 080(a)

15 11-Dichloroethene 96 1547 1547 (0431) 7415 100000 11

16 Acetone 58 1882 1882 (0524) 5188 500000 61

18 Carbon Disulfide 76 1559 1559 (0434) 32446 100000 10

27 Methyl Acetate 74 1955 1955 (0545) 2222 100000 11

22 Methylene Chloride 49 1851 1851 (0516) 20667 100000 12

28 MTBE 73 2016 2016 (0562) 32806 100000 10

25 trans-12-Dichloroethene 96 1937 1937 (0540) 9445 100000 100

30 11-Dichloroethane 63 2303 2303 (0642) 21457 100000 10

36 cis-12-Dichloroethene 96 2644 2644 (0737) 11702 100000 11

10162012Page 78 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07836d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0856) 6291 500000 40(a)

42 Chloroform 83 2839 2839 (0791) 17974 100000 098(a)

44 Cyclohexane 56 2778 2778 (0774) 14380 100000 075(a)

43 111-Trichloroethane 97 2973 2973 (0828) 14264 100000 092(a)

45 Carbon Tetrachloride 117 2924 2924 (0815) 11168 100000 089(a)

48 Benzene 78 3254 3254 (0468) 45050 100000 10

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 599539 500000 49

49 12-Dichloroethane 62 3412 3412 (0951) 15679 100000 10

52 Fluorobenzene 96 3589 3589 (1000) 2307227 500000

54 Trichloroethene 95 3735 3735 (1041) 11865 100000 11

56 Methyl cyclohexane 83 3723 3723 (1037) 10486 100000 068(a)

57 12-Dichloropropane 63 4192 4192 (1168) 12728 100000 10

68 Bromodichloromethane 83 4266 4266 (1189) 14807 100000 10

67 cis-13-Dichloropropene 75 4906 4906 (0706) 18914 100000 095(a)

70 4-Methyl-2-Pentanone 43 5625 5625 (0810) 67258 500000 50

$ 65 Toluene-d8 (SUR) 98 5101 5101 (0734) 2133452 500000 49

66 Toluene 91 5156 5156 (0742) 51238 100000 10

64 trans-13-Dichloropropene 75 5650 5650 (0813) 17115 100000 095(a)

69 112-Trichloroethane 83 5826 5826 (0839) 8636 100000 10

71 Tetrachloroethene 166 5582 5582 (0803) 10238 100000 088(a)

73 2-Hexanone 43 6674 6674 (0960) 49729 500000 50

74 Dibromochloromethane 129 6015 6015 (0866) 11301 100000 098(a)

77 12-Dibromoethane 107 6265 6265 (0902) 9735 100000 097(a)

78 Chlorobenzene-d5 117 6948 6948 (1000) 1875221 500000

79 Chlorobenzene 112 6972 6972 (1004) 33596 100000 10

81 Ethylbenzene 106 7064 7064 (1017) 17061 100000 096(a)

82 m+p-Xylene 106 7271 7271 (1046) 44761 200000 20

84 o-Xylene 106 7856 7856 (1131) 21499 100000 097(a)

85 Styrene 104 7942 7942 (1143) 36217 100000 096(a)

86 Bromoform 173 7911 7911 (1139) 7698 100000 096(a)

88 Isopropylbenzene 105 8344 8344 (1201) 49933 100000 094(a)

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 823604 500000 48

92 1122-Tetrachloroethane 83 9112 9112 (0871) 13823 100000 10

105 13-Dichlorobenzene 146 10332 10332 (0987) 26644 100000 099(a)

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1055978 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 28798 100000 10

111 12-Dichlorobenzene 146 11148 11148 (1065) 25972 100000 10(H)

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 2725 100000 11

114 124-Trichlorobenzene 180 12971 12971 (1239) 13808 100000 11

M 120 12-Dichloroethene (Total) 100 21147 200000 21

M 121 Xylene (Total) 100 66260 300000 30

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

H - Operator selected an alternate compound hit

10162012Page 79 of 323

Data File e07836d

Date 17-SEP-2012 0449

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL1 Operator GCMS VOAMS5

10162012Page 80 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07838d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07838dLab Smp Id IC-VMCAL2 Inj Date 17-SEP-2012 0536 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL2Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 4 Calibration Sample Level 2Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 39416 500000 48

3 Chloromethane 50 1016 1016 (0283) 83523 500000 48

4 Vinyl Chloride 62 1022 1022 (0285) 66919 500000 49

6 Bromomethane 94 1169 1169 (0326) 33032 500000 55

5 Chloroethane 64 1230 1230 (0343) 29332 500000 58

7 Trichlorofluoromethane 101 1291 1291 (0360) 49780 500000 45

14 Freon TF 101 1559 1559 (0434) 37580 500000 48

15 11-Dichloroethene 96 1541 1541 (0429) 31234 500000 45

16 Acetone 58 1894 1894 (0528) 13342 150000 16

18 Carbon Disulfide 76 1553 1553 (0433) 149121 500000 47

27 Methyl Acetate 74 1961 1961 (0546) 10660 500000 54

22 Methylene Chloride 49 1851 1851 (0516) 86862 500000 53

28 MTBE 73 2016 2016 (0562) 167790 500000 53

25 trans-12-Dichloroethene 96 1937 1937 (0540) 45844 500000 48

30 11-Dichloroethane 63 2296 2296 (0640) 104265 500000 49

36 cis-12-Dichloroethene 96 2644 2644 (0737) 55218 500000 51

10162012Page 81 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07838d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0857) 19260 150000 12

42 Chloroform 83 2839 2839 (0791) 94697 500000 52

44 Cyclohexane 56 2772 2772 (0772) 96765 500000 51

43 111-Trichloroethane 97 2973 2973 (0828) 71766 500000 46

45 Carbon Tetrachloride 117 2924 2924 (0815) 54679 500000 44

48 Benzene 78 3254 3254 (0468) 227079 500000 53

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 630441 500000 52

49 12-Dichloroethane 62 3412 3412 (0951) 78926 500000 52

52 Fluorobenzene 96 3589 3589 (1000) 2304638 500000

54 Trichloroethene 95 3735 3735 (1041) 50527 500000 46

56 Methyl cyclohexane 83 3717 3717 (1036) 79279 500000 52

57 12-Dichloropropane 63 4192 4192 (1168) 64209 500000 50

68 Bromodichloromethane 83 4272 4272 (1190) 72835 500000 49

67 cis-13-Dichloropropene 75 4906 4906 (0706) 95905 500000 50

70 4-Methyl-2-Pentanone 43 5625 5625 (0810) 195851 150000 15

$ 65 Toluene-d8 (SUR) 98 5101 5101 (0734) 2179204 500000 52

66 Toluene 91 5156 5156 (0742) 243768 500000 51

64 trans-13-Dichloropropene 75 5643 5643 (0812) 85943 500000 49

69 112-Trichloroethane 83 5820 5820 (0838) 42154 500000 51

71 Tetrachloroethene 166 5576 5576 (0803) 51530 500000 46

73 2-Hexanone 43 6680 6680 (0961) 148758 150000 15

74 Dibromochloromethane 129 6015 6015 (0866) 54107 500000 48

77 12-Dibromoethane 107 6259 6259 (0901) 49066 500000 51

78 Chlorobenzene-d5 117 6948 6948 (1000) 1811885 500000

79 Chlorobenzene 112 6972 6972 (1004) 162793 500000 50

81 Ethylbenzene 106 7058 7058 (1016) 81955 500000 48

82 m+p-Xylene 106 7271 7271 (1046) 208423 100000 97

84 o-Xylene 106 7856 7856 (1131) 102832 500000 48

85 Styrene 104 7942 7942 (1143) 179367 500000 50

86 Bromoform 173 7911 7911 (1139) 36074 500000 46

88 Isopropylbenzene 105 8344 8344 (1201) 244766 500000 48

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 813301 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 63947 500000 50

105 13-Dichlorobenzene 146 10325 10325 (0987) 126663 500000 50

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 998386 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 130929 500000 49

111 12-Dichlorobenzene 146 11148 11148 (1065) 121236 500000 50

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 11615 500000 51

114 124-Trichlorobenzene 180 12965 12965 (1239) 61295 500000 50

M 120 12-Dichloroethene (Total) 100 101062 100000 99

M 121 Xylene (Total) 100 311255 150000 14

10162012Page 82 of 323

Data File e07838d

Date 17-SEP-2012 0536

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL2 Operator GCMS VOAMS5

10162012Page 83 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07839d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07839dLab Smp Id ICIS-VMCAL3 Inj Date 17-SEP-2012 0600 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info ICIS-VMCAL3Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 5 Calibration Sample Level 3Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 167418 200000 20

3 Chloromethane 50 1016 1016 (0283) 353287 200000 20

4 Vinyl Chloride 62 1016 1016 (0283) 281874 200000 20

6 Bromomethane 94 1175 1175 (0327) 118799 200000 19

5 Chloroethane 64 1230 1230 (0343) 107678 200000 21

7 Trichlorofluoromethane 101 1291 1291 (0360) 228376 200000 20

14 Freon TF 101 1559 1559 (0434) 157867 200000 20

15 11-Dichloroethene 96 1540 1540 (0429) 147259 200000 21

16 Acetone 58 1888 1888 (0526) 17849 200000 20

18 Carbon Disulfide 76 1559 1559 (0434) 648801 200000 20

27 Methyl Acetate 74 1955 1955 (0545) 39926 200000 20

22 Methylene Chloride 49 1851 1851 (0516) 340378 200000 20

28 MTBE 73 2016 2016 (0562) 658123 200000 20

25 trans-12-Dichloroethene 96 1943 1943 (0541) 203500 200000 21

30 11-Dichloroethane 63 2303 2303 (0642) 465144 200000 21

36 cis-12-Dichloroethene 96 2644 2644 (0737) 233129 200000 21

10162012Page 84 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07839d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0856) 36552 200000 22

42 Chloroform 83 2839 2839 (0791) 383084 200000 20

44 Cyclohexane 56 2778 2778 (0774) 383104 200000 19

43 111-Trichloroethane 97 2973 2973 (0828) 333961 200000 21

45 Carbon Tetrachloride 117 2924 2924 (0815) 265527 200000 21

48 Benzene 78 3254 3254 (0468) 968083 200000 21

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0935) 611357 500000 49

49 12-Dichloroethane 62 3412 3412 (0951) 312991 200000 20

52 Fluorobenzene 96 3589 3589 (1000) 2376396 500000

54 Trichloroethene 95 3735 3735 (1041) 229465 200000 20

56 Methyl cyclohexane 83 3723 3723 (1037) 312424 200000 20

57 12-Dichloropropane 63 4192 4192 (1168) 266559 200000 20

68 Bromodichloromethane 83 4266 4266 (1189) 302742 200000 20

67 cis-13-Dichloropropene 75 4906 4906 (0705) 412847 200000 20

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 271059 200000 20

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2252606 500000 50

66 Toluene 91 5156 5156 (0741) 1095520 200000 22

64 trans-13-Dichloropropene 75 5643 5643 (0812) 369516 200000 20

69 112-Trichloroethane 83 5820 5820 (0837) 175853 200000 20

71 Tetrachloroethene 166 5576 5576 (0802) 258990 200000 22

73 2-Hexanone 43 6680 6680 (0961) 205286 200000 20

74 Dibromochloromethane 129 6015 6015 (0865) 237421 200000 20

77 12-Dibromoethane 107 6259 6259 (0900) 210900 200000 20

78 Chlorobenzene-d5 117 6954 6954 (1000) 1921967 500000

79 Chlorobenzene 112 6972 6972 (1003) 714336 200000 21

81 Ethylbenzene 106 7064 7064 (1016) 380762 200000 21

82 m+p-Xylene 106 7277 7277 (1046) 968280 400000 42

84 o-Xylene 106 7856 7856 (1130) 472158 200000 21

85 Styrene 104 7942 7942 (1142) 809158 200000 21

86 Bromoform 173 7911 7911 (1138) 165267 200000 20

88 Isopropylbenzene 105 8344 8344 (1200) 1199765 200000 22

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 847619 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 277413 200000 20

105 13-Dichlorobenzene 146 10325 10325 (0987) 557342 200000 21

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1048295 500000

109 14-Dichlorobenzene 146 10484 10484 (1002) 574816 200000 21

111 12-Dichlorobenzene 146 11148 11148 (1065) 528396 200000 21

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 45388 200000 19

114 124-Trichlorobenzene 180 12965 12965 (1239) 264648 200000 21

M 120 12-Dichloroethene (Total) 100 436629 400000 42

M 121 Xylene (Total) 100 1440438 600000 63

10162012Page 85 of 323

Data File e07839d

Date 17-SEP-2012 0600

Client ID Instrument VOAMS5i

Sample Info ICIS-VMCAL3 Operator GCMS VOAMS5

10162012Page 86 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07840d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07840dLab Smp Id IC-VMCAL4 Inj Date 17-SEP-2012 0623 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL4Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 6 Calibration Sample Level 4Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 450014 500000 53

3 Chloromethane 50 1010 1010 (0281) 935453 500000 52

4 Vinyl Chloride 62 1016 1016 (0283) 757876 500000 53

6 Bromomethane 94 1175 1175 (0327) 307121 500000 49

5 Chloroethane 64 1230 1230 (0342) 284219 500000 54

7 Trichlorofluoromethane 101 1290 1290 (0359) 566305 500000 49

14 Freon TF 101 1565 1565 (0435) 443949 500000 55

15 11-Dichloroethene 96 1540 1540 (0428) 355088 500000 49

16 Acetone 58 1888 1888 (0525) 43750 500000 50

18 Carbon Disulfide 76 1559 1559 (0434) 1763903 500000 53

27 Methyl Acetate 74 1961 1961 (0546) 101112 500000 49

22 Methylene Chloride 49 1851 1851 (0515) 840419 500000 49

28 MTBE 73 2016 2016 (0561) 1636664 500000 50

25 trans-12-Dichloroethene 96 1943 1943 (0540) 521911 500000 53

30 11-Dichloroethane 63 2302 2302 (0640) 1121930 500000 51

36 cis-12-Dichloroethene 96 2644 2644 (0735) 567238 500000 50

10162012Page 87 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07840d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0854) 89217 500000 54

42 Chloroform 83 2839 2839 (0790) 974788 500000 51

44 Cyclohexane 56 2778 2778 (0773) 1067735 500000 54

43 111-Trichloroethane 97 2973 2973 (0827) 821993 500000 51

45 Carbon Tetrachloride 117 2924 2924 (0813) 675330 500000 52

48 Benzene 78 3254 3254 (0468) 2380099 500000 51

$ 47 12-Dichloroethane-d4 (SUR) 65 3357 3357 (0934) 613057 500000 48

49 12-Dichloroethane 62 3412 3412 (0949) 785178 500000 50

52 Fluorobenzene 96 3595 3595 (1000) 2400971 500000

54 Trichloroethene 95 3735 3735 (1039) 562086 500000 49

56 Methyl cyclohexane 83 3723 3723 (1036) 894738 500000 56

57 12-Dichloropropane 63 4192 4192 (1166) 655380 500000 50

68 Bromodichloromethane 83 4272 4272 (1188) 754124 500000 49

67 cis-13-Dichloropropene 75 4906 4906 (0705) 1024782 500000 49

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 697282 500000 49

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2273339 500000 50

66 Toluene 91 5162 5162 (0742) 2719268 500000 52

64 trans-13-Dichloropropene 75 5649 5649 (0812) 938808 500000 50

69 112-Trichloroethane 83 5820 5820 (0837) 432262 500000 49

71 Tetrachloroethene 166 5576 5576 (0802) 639002 500000 52

73 2-Hexanone 43 6680 6680 (0961) 526223 500000 50

74 Dibromochloromethane 129 6015 6015 (0865) 599464 500000 49

77 12-Dibromoethane 107 6259 6259 (0900) 524614 500000 50

78 Chlorobenzene-d5 117 6954 6954 (1000) 1964266 500000

79 Chlorobenzene 112 6972 6972 (1003) 1781568 500000 51

81 Ethylbenzene 106 7064 7064 (1016) 955894 500000 51

82 m+p-Xylene 106 7277 7277 (1046) 2423002 100000 100

84 o-Xylene 106 7862 7862 (1131) 1181273 500000 51

85 Styrene 104 7942 7942 (1142) 2064560 500000 52

86 Bromoform 173 7911 7911 (1138) 430943 500000 51

88 Isopropylbenzene 105 8350 8350 (1201) 3014281 500000 54

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 870646 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 702309 500000 50

105 13-Dichlorobenzene 146 10331 10331 (0987) 1421450 500000 51

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 1082388 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 1464915 500000 51

111 12-Dichlorobenzene 146 11154 11154 (1066) 1324016 500000 50

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 120062 500000 49

114 124-Trichlorobenzene 180 12971 12971 (1239) 678119 500000 51

M 120 12-Dichloroethene (Total) 100 1089149 100000 100

M 121 Xylene (Total) 100 3604275 150000 160

10162012Page 88 of 323

Data File e07840d

Date 17-SEP-2012 0623

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL4 Operator GCMS VOAMS5

10162012Page 89 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07841d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07841dLab Smp Id IC-VMCAL5 Inj Date 17-SEP-2012 0646 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL5Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 7 Calibration Sample Level 5Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 1798263 200000 200

3 Chloromethane 50 1010 1010 (0281) 3551906 200000 190

4 Vinyl Chloride 62 1016 1016 (0283) 2954383 200000 200

6 Bromomethane 94 1175 1175 (0327) 1285567 200000 190

5 Chloroethane 64 1230 1230 (0342) 1005976 200000 180

7 Trichlorofluoromethane 101 1291 1291 (0359) 2495326 200000 200

14 Freon TF 101 1565 1565 (0435) 1913025 200000 220

15 11-Dichloroethene 96 1541 1541 (0429) 1549102 200000 200

16 Acetone 58 1894 1894 (0527) 164598 200000 180

18 Carbon Disulfide 76 1559 1559 (0434) 7384049 200000 210

27 Methyl Acetate 74 1961 1961 (0546) 407713 200000 190

22 Methylene Chloride 49 1851 1851 (0515) 3225631 200000 180

28 MTBE 73 2016 2016 (0561) 7002522 200000 200

25 trans-12-Dichloroethene 96 1943 1943 (0540) 2044335 200000 200

30 11-Dichloroethane 63 2303 2303 (0640) 4556341 200000 200

36 cis-12-Dichloroethene 96 2650 2650 (0737) 2267968 200000 190

10162012Page 90 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07841d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3071 (0854) 377317 200000 220

42 Chloroform 83 2839 2839 (0790) 4002506 200000 200

44 Cyclohexane 56 2784 2784 (0774) 4704103 200000 220

43 111-Trichloroethane 97 2979 2979 (0829) 3633125 200000 210

45 Carbon Tetrachloride 117 2930 2930 (0815) 2970592 200000 220

48 Benzene 78 3260 3260 (0468) 9863557 200000 210

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 676105 500000 50

49 12-Dichloroethane 62 3418 3418 (0951) 3236838 200000 190

52 Fluorobenzene 96 3595 3595 (1000) 2534623 500000

54 Trichloroethene 95 3741 3741 (1041) 2397838 200000 200

56 Methyl cyclohexane 83 3729 3729 (1037) 3740947 200000 220

57 12-Dichloropropane 63 4199 4199 (1168) 2762116 200000 200

68 Bromodichloromethane 83 4272 4272 (1188) 3283607 200000 200

67 cis-13-Dichloropropene 75 4912 4912 (0706) 4330221 200000 200

70 4-Methyl-2-Pentanone 43 5631 5631 (0809) 2892746 200000 200

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 2337515 500000 50

66 Toluene 91 5162 5162 (0742) 10779721 200000 200

64 trans-13-Dichloropropene 75 5656 5656 (0813) 3942425 200000 200

69 112-Trichloroethane 83 5826 5826 (0837) 1754301 200000 190

71 Tetrachloroethene 166 5582 5582 (0802) 2589541 200000 210

73 2-Hexanone 43 6686 6686 (0961) 2211715 200000 210

74 Dibromochloromethane 129 6021 6021 (0865) 2498269 200000 200

77 12-Dibromoethane 107 6265 6265 (0900) 2110766 200000 200

78 Chlorobenzene-d5 117 6960 6960 (1000) 2007362 500000

79 Chlorobenzene 112 6978 6978 (1003) 7007520 200000 200

81 Ethylbenzene 106 7076 7076 (1017) 3881643 200000 200

82 m+p-Xylene 106 7289 7289 (1047) 9786882 400000 410

84 o-Xylene 106 7869 7869 (1131) 4809215 200000 200

85 Styrene 104 7954 7954 (1143) 8412645 200000 210

86 Bromoform 173 7923 7923 (1138) 1812795 200000 210

88 Isopropylbenzene 105 8356 8356 (1201) 12317103 200000 220(A)

$ 89 Bromofluorobenzene (SUR) 174 8716 8716 (0832) 929176 500000 51

92 1122-Tetrachloroethane 83 9124 9124 (0871) 2898768 200000 200

105 13-Dichlorobenzene 146 10344 10344 (0987) 5787314 200000 200

108 14-Dichlorobenzene-d4 152 10478 10478 (1000) 1134091 500000

109 14-Dichlorobenzene 146 10502 10502 (1002) 5901891 200000 200

111 12-Dichlorobenzene 146 11167 11167 (1066) 5328621 200000 190

112 12-Dibromo-3-chloropropane 75 12240 12240 (1168) 472744 200000 180

114 124-Trichlorobenzene 180 12971 12971 (1238) 2596959 200000 190

M 120 12-Dichloroethene (Total) 100 4312303 400000 380

M 121 Xylene (Total) 100 14596097 600000 620

QC Flag Legend

A - Target compound detected but quantitated amountexceeded maximum amount

10162012Page 91 of 323

Data File e07841d

Date 17-SEP-2012 0646

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL5 Operator GCMS VOAMS5

10162012Page 92 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07842d Report Date 17-Sep-2012 1317

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1217sep12be07842dLab Smp Id IC-VMCAL6 Inj Date 17-SEP-2012 0710 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info IC-VMCAL6Misc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12b8260DE_09mMeth Date 17-Sep-2012 1317 vibha Quant Type ISTDCal Date 17-SEP-2012 0600 Cal File e07839dAls bottle 8 Calibration Sample Level 6Dil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0888 0888 (0247) 4551928 500000 450

3 Chloromethane 50 1010 1010 (0280) 8902969 500000 410

4 Vinyl Chloride 62 1016 1016 (0282) 7332518 500000 420

6 Bromomethane 94 1175 1175 (0326) 3429373 500000 450

5 Chloroethane 64 1230 1230 (0341) 2426216 500000 380

7 Trichlorofluoromethane 101 1297 1297 (0360) 6618134 500000 470

14 Freon TF 101 1571 1571 (0436) 5130629 500000 520(A)

15 11-Dichloroethene 96 1547 1547 (0429) 4214942 500000 490

16 Acetone 58 1894 1894 (0526) 441742 500000 420

18 Carbon Disulfide 76 1559 1559 (0433) 18433408 500000 460

27 Methyl Acetate 74 1961 1961 (0545) 1074355 500000 440

22 Methylene Chloride 49 1851 1851 (0514) 8533685 500000 410

28 MTBE 73 2022 2022 (0562) 17351574 500000 440

25 trans-12-Dichloroethene 96 1943 1943 (0540) 5633771 500000 470

30 11-Dichloroethane 63 2302 2302 (0639) 12326764 500000 460

36 cis-12-Dichloroethene 96 2650 2650 (0736) 6324299 500000 460

10162012Page 93 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07842d Report Date 17-Sep-2012 1317

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3083 3083 (0856) 1055008 500000 530(A)

42 Chloroform 83 2845 2845 (0790) 11152231 500000 480

44 Cyclohexane 56 2790 2790 (0775) 12852489 500000 540(A)

43 111-Trichloroethane 97 2985 2985 (0829) 10199723 500000 520(A)

45 Carbon Tetrachloride 117 2936 2936 (0815) 8405131 500000 540(A)

48 Benzene 78 3260 3260 (0468) 21876514 500000 410

$ 47 12-Dichloroethane-d4 (SUR) 65 3369 3369 (0936) 782507 500000 51

49 12-Dichloroethane 62 3424 3424 (0951) 9046377 500000 480

52 Fluorobenzene 96 3601 3601 (1000) 2895790 500000

54 Trichloroethene 95 3753 3753 (1042) 7026524 500000 510(A)

56 Methyl cyclohexane 83 3741 3741 (1039) 10227785 500000 530(A)

57 12-Dichloropropane 63 4205 4205 (1168) 7913672 500000 500

68 Bromodichloromethane 83 4284 4284 (1190) 9374106 500000 510(A)

67 cis-13-Dichloropropene 75 4924 4924 (0706) 12299317 500000 520(A)

70 4-Methyl-2-Pentanone 43 5649 5649 (0810) 8212153 500000 510(A)

$ 65 Toluene-d8 (SUR) 98 5113 5113 (0733) 2600040 500000 50

66 Toluene 91 5168 5168 (0741) 23868197 500000 400

64 trans-13-Dichloropropene 75 5668 5668 (0813) 11373599 500000 530(A)

69 112-Trichloroethane 83 5838 5838 (0837) 5071317 500000 500(A)

71 Tetrachloroethene 166 5594 5594 (0802) 7239654 500000 520(A)

73 2-Hexanone 43 6698 6698 (0961) 5590902 500000 470

74 Dibromochloromethane 129 6033 6033 (0865) 7227226 500000 530(A)

77 12-Dibromoethane 107 6277 6277 (0900) 5952425 500000 500(A)

78 Chlorobenzene-d5 117 6972 6972 (1000) 2224153 500000

79 Chlorobenzene 112 6997 6997 (1003) 18374405 500000 460

81 Ethylbenzene 106 7094 7094 (1017) 10693410 500000 500(A)

82 m+p-Xylene 106 7308 7308 (1048) 23238078 100000 880

84 o-Xylene 106 7887 7887 (1131) 12821590 500000 490

85 Styrene 104 7966 7966 (1143) 19831782 500000 440

86 Bromoform 173 7942 7942 (1139) 4974461 500000 520(A)

88 Isopropylbenzene 105 8368 8368 (1200) 26165908 500000 420(A)

$ 89 Bromofluorobenzene (SUR) 174 8728 8728 (0832) 954872 500000 51

92 1122-Tetrachloroethane 83 9143 9143 (0871) 7365342 500000 490

105 13-Dichlorobenzene 146 10362 10362 (0987) 14243841 500000 480

108 14-Dichlorobenzene-d4 152 10496 10496 (1000) 1163568 500000

109 14-Dichlorobenzene 146 10526 10526 (1003) 14602396 500000 470

111 12-Dichlorobenzene 146 11185 11185 (1066) 13405399 500000 480

112 12-Dibromo-3-chloropropane 75 12246 12246 (1167) 1274610 500000 480

114 124-Trichlorobenzene 180 12977 12977 (1236) 6669727 500000 470

M 120 12-Dichloroethene (Total) 100 11958070 100000 940

M 121 Xylene (Total) 100 36059668 150000 1400

QC Flag Legend

A - Target compound detected but quantitated amountexceeded maximum amount

10162012Page 94 of 323

Data File e07842d

Date 17-SEP-2012 0710

Client ID Instrument VOAMS5i

Sample Info IC-VMCAL6 Operator GCMS VOAMS5

10162012Page 95 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10112012 2050

09172012 0449

09172012 0710

CCVIS 460-1316562

Rtx-VMS

TestAmerica Edison

Lab File ID e08976d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Dichlorodifluoromethane 0194701761 01000 221 200 105 250Ave

Chloromethane 0322303733 01000 173 200 -137 250Ave

Vinyl chloride 0274402985 01000 184 200 -81 250Ave

Bromomethane 0159401312 01000 243 200 215 250Ave

Chloroethane 0127501099 01000 232 200 160 250Ave

Trichlorofluoromethane 0296002422 01000 244 200 222 250Ave

11-Dichloroethene 0161001496 01000 215 200 76 250Ave

Carbon disulfide 0655806887 01000 190 200 -48 250Ave

112-Trichloro-122-trifluoroethane

0198901691 01000 235 200 176 250Ave

Methylene Chloride 0341503576 01000 191 200 -45 250Ave

Acetone 0021400184 01000 233 200 164 250Ave

trans-12-Dichloroethene 0208902052 01000 204 200 18 250Ave

Methyl acetate 0037700426 01000 177 200 -115 250Ave

Methyl tert-butyl ether 0665806838 01000 195 200 -26 250Ave

11-Dichloroethane 0443404582 01000 194 200 -32 250Ave

cis-12-Dichloroethene 0227602361 01000 193 200 -36 250Ave

Cyclohexane 0338904145 01000 163 200 -183 250Ave

Chloroform 0397703982 01000 200 200 -01 250Ave

Carbon tetrachloride 0281602705 01000 208 200 41 250Ave

111-Trichloroethane 0352303375 01000 209 200 44 250Ave

2-Butanone (MEK) 0035400341 01000 208 200 40 250Ave

Benzene 10301190 01000 173 200 -134 250Ave

12-Dichloroethane 0331603284 01000 202 200 10 250Ave

Methylcyclohexane 0280603325 01000 169 200 -156 250Ave

Trichloroethene 0228602385 01000 192 200 -41 250Ave

12-Dichloropropane 0242002756 01000 176 200 -122 250Ave

Dichlorobromomethane 0303603195 01000 190 200 -50 250Ave

cis-13-Dichloropropene 0438605308 01000 165 200 -174 250Ave

Toluene 12151323 01000 184 200 -81 250Ave

Tetrachloroethene 0302803113 01000 195 200 -27 250Ave

4-Methyl-2-pentanone (MIBK) 0273203593 01000 152 200 -240 250Ave

trans-13-Dichloropropene 0396604819 01000 165 200 -177 250Ave

112-Trichloroethane 0185102264 01000 164 200 -182 250Ave

Chlorodibromomethane 0265003083 01000 172 200 -141 250Ave

12-Dibromoethane 0231002670 01000 173 200 -135 250Ave

2-Hexanone 0209702668 01000 157 200 -214 250Ave

Chlorobenzene 0830208882 01000 187 200 -65 250Ave

Ethylbenzene 0437104756 01000 184 200 -81 250Ave

m-Xylene amp p-Xylene 0555805917 01000 376 400 -61 250Ave

o-Xylene 0545405886 01000 185 200 -73 250Ave

FORM VII 8260B

10162012Page 96 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10112012 2050

09172012 0449

09172012 0710

CCVIS 460-1316562

Rtx-VMS

TestAmerica Edison

Lab File ID e08976d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Bromoform 0188102147 01000 175 200 -124 250Ave

Styrene 092181000 01000 184 200 -78 250Ave

Isopropylbenzene 13421415 01000 190 200 -52 250Ave

1122-Tetrachloroethane 0512306462 01000 159 200 -207 250Ave

13-Dichlorobenzene 11861279 01000 186 200 -72 250Ave

14-Dichlorobenzene 12311326 01000 186 200 -72 250Ave

12-Dichlorobenzene 11211209 01000 185 200 -73 250Ave

12-Dibromo-3-Chloropropane 0086101130 01000 152 200 -238 250Ave

124-Trichlorobenzene 0630306118 01000 206 200 30 250Ave

12-Dichloroethane-d4 (Surr) 0310902638 01000 589 500 178 250Ave

Toluene-d8 (Surr) 11551167 01000 495 500 -11 250Ave

4-Bromofluorobenzene 0811108079 01000 502 500 04 250Ave

FORM VII 8260B

10162012Page 97 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08976d Report Date 11-Oct-2012 2130

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08976dLab Smp Id CCVIS Inj Date 11-OCT-2012 2050 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info CCVISMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 1 Continuing Calibration SampleDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0900 0900 (0250) 102235 200000 22

3 Chloromethane 50 1016 1016 (0282) 169224 200000 17

4 Vinyl Chloride 62 1028 1028 (0286) 144069 200000 18

6 Bromomethane 94 1181 1181 (0328) 83687 200000 24

5 Chloroethane 64 1242 1242 (0345) 66969 200000 23

7 Trichlorofluoromethane 101 1303 1303 (0362) 155393 200000 24

14 Freon TF 101 1577 1577 (0438) 104446 200000 24

15 11-Dichloroethene 96 1553 1553 (0431) 84531 200000 22

16 Acetone 58 1894 1894 (0526) 11228 200000 23

18 Carbon Disulfide 76 1571 1571 (0436) 344348 200000 19

27 Methyl Acetate 74 1967 1967 (0546) 19813 200000 18

22 Methylene Chloride 49 1864 1864 (0518) 179288 200000 19

28 MTBE 73 2022 2022 (0562) 349596 200000 19

25 trans-12-Dichloroethene 96 1949 1949 (0541) 109681 200000 20

30 11-Dichloroethane 63 2309 2309 (0641) 232818 200000 19

36 cis-12-Dichloroethene 96 2656 2656 (0738) 119502 200000 19

10162012Page 98 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08976d Report Date 11-Oct-2012 2130

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0854) 18598 200000 21

42 Chloroform 83 2845 2845 (0790) 208815 200000 20

44 Cyclohexane 56 2784 2784 (0773) 177923 200000 16

43 111-Trichloroethane 97 2985 2985 (0829) 185002 200000 21

45 Carbon Tetrachloride 117 2937 2937 (0815) 147853 200000 21

48 Benzene 78 3260 3260 (0469) 476925 200000 17

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0934) 408134 500000 59

49 12-Dichloroethane 62 3418 3418 (0949) 174132 200000 20

52 Fluorobenzene 96 3601 3601 (1000) 1312656 500000

54 Trichloroethene 95 3741 3741 (1039) 120041 200000 19

56 Methyl cyclohexane 83 3729 3729 (1036) 147336 200000 17

57 12-Dichloropropane 63 4199 4199 (1166) 127078 200000 18

68 Bromodichloromethane 83 4272 4272 (1186) 159386 200000 19

67 cis-13-Dichloropropene 75 4912 4912 (0706) 203059 200000 16

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 126467 200000 15

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1336847 500000 49

66 Toluene 91 5162 5162 (0742) 562689 200000 18

64 trans-13-Dichloropropene 75 5649 5649 (0812) 183587 200000 16

69 112-Trichloroethane 83 5820 5820 (0837) 85707 200000 16

71 Tetrachloroethene 166 5582 5582 (0803) 140177 200000 19

73 2-Hexanone 43 6680 6680 (0961) 97080 200000 16

74 Dibromochloromethane 129 6021 6021 (0866) 122657 200000 17

77 12-Dibromoethane 107 6265 6265 (0901) 106920 200000 17

78 Chlorobenzene-d5 117 6954 6954 (1000) 1157341 500000

79 Chlorobenzene 112 6972 6972 (1003) 384334 200000 19

81 Ethylbenzene 106 7064 7064 (1016) 202362 200000 18

82 m+p-Xylene 106 7277 7277 (1046) 514606 400000 38

84 o-Xylene 106 7862 7862 (1131) 252476 200000 18

85 Styrene 104 7942 7942 (1142) 426740 200000 18

86 Bromoform 173 7911 7911 (1138) 87078 200000 18

88 Isopropylbenzene 105 8350 8350 (1201) 621124 200000 19

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 541700 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 136860 200000 16

105 13-Dichlorobenzene 146 10331 10331 (0987) 316835 200000 18

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 667834 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 328709 200000 18

111 12-Dichlorobenzene 146 11148 11148 (1065) 299393 200000 18

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 23001 200000 15

114 124-Trichlorobenzene 180 12977 12977 (1240) 168371 200000 21

M 120 12-Dichloroethene (Total) 100 229183 400000 40

M 121 Xylene (Total) 100 767082 600000 56

10162012Page 99 of 323

Data File e08976d

Date 11-OCT-2012 2050

Client ID Instrument VOAMS5i

Sample Info CCVIS Operator GCMS VOAMS5

10162012Page 100 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10122012 0114

09172012 0449

09172012 0710

CCV 460-13165610

Rtx-VMS

TestAmerica Edison

Lab File ID e08987d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Dichlorodifluoromethane 0166601761 01000 189 200 -54 250Ave

Chloromethane 0311403733 01000 167 200 -166 250Ave

Vinyl chloride 0256002985 01000 172 200 -142 250Ave

Bromomethane 0162301312 01000 247 200 237 250Ave

Chloroethane 0127201099 01000 231 200 157 250Ave

Trichlorofluoromethane 0257102422 01000 212 200 62 250Ave

11-Dichloroethene 0184901496 01000 247 200 236 250Ave

112-Trichloro-122-trifluoroethane

0225501691 01000 267 200 334 250Ave

Carbon disulfide 0788506887 01000 229 200 145 250Ave

Methylene Chloride 0351303576 01000 196 200 -18 250Ave

Acetone 0022000184 01000 239 200 197 250Ave

trans-12-Dichloroethene 0232002052 01000 226 200 130 250Ave

Methyl acetate 0048700426 01000 228 200 141 250Ave

Methyl tert-butyl ether 0769506838 01000 225 200 125 250Ave

11-Dichloroethane 0469804582 01000 205 200 25 250Ave

cis-12-Dichloroethene 0240902361 01000 204 200 20 250Ave

Cyclohexane 0384004145 01000 185 200 -74 250Ave

Chloroform 0438203982 01000 220 200 100 250Ave

Carbon tetrachloride 0291802705 01000 216 200 79 250Ave

111-Trichloroethane 0362803375 01000 215 200 75 250Ave

2-Butanone (MEK) 0042500341 01000 250 200 248 250Ave

Benzene 11151190 01000 188 200 -62 250Ave

12-Dichloroethane 0359603284 01000 219 200 95 250Ave

Methylcyclohexane 0344803325 01000 207 200 37 250Ave

Trichloroethene 0248302385 01000 208 200 41 250Ave

12-Dichloropropane 0265202756 01000 192 200 -38 250Ave

Dichlorobromomethane 0339803195 01000 213 200 63 250Ave

cis-13-Dichloropropene 0490405308 01000 185 200 -76 250Ave

Toluene 12801323 01000 194 200 -32 250Ave

Tetrachloroethene 0323103113 01000 208 200 38 250Ave

4-Methyl-2-pentanone (MIBK) 0319703593 01000 178 200 -110 250Ave

trans-13-Dichloropropene 0454104819 01000 188 200 -58 250Ave

112-Trichloroethane 0212502264 01000 188 200 -61 250Ave

Chlorodibromomethane 0306403083 01000 199 200 -06 250Ave

12-Dibromoethane 0261302670 01000 196 200 -22 250Ave

2-Hexanone 0243802668 01000 183 200 -86 250Ave

Chlorobenzene 0879308882 01000 198 200 -10 250Ave

Ethylbenzene 0463104756 01000 195 200 -26 250Ave

m-Xylene amp p-Xylene 0587505917 01000 397 400 -07 250Ave

o-Xylene 0578505886 01000 197 200 -17 250Ave

FORM VII 8260B

10162012Page 101 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GCMS VOA CONTINUING CALIBRATION DATA

018(mm)

460-45537-1

VOAMS5

10122012 0114

09172012 0449

09172012 0710

CCV 460-13165610

Rtx-VMS

TestAmerica Edison

Lab File ID e08987d Heated Purge (YN) NConc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE RRF RRF MIN RRF

Bromoform 0223102147 01000 208 200 39 250Ave

Styrene 099051000 01000 198 200 -09 250Ave

Isopropylbenzene 14391415 01000 203 200 17 250Ave

1122-Tetrachloroethane 0579606462 01000 179 200 -103 250Ave

13-Dichlorobenzene 12591279 01000 197 200 -15 250Ave

14-Dichlorobenzene 13061326 01000 197 200 -15 250Ave

12-Dichlorobenzene 12151209 01000 201 200 05 250Ave

12-Dibromo-3-Chloropropane 0102901130 01000 182 200 -90 250Ave

124-Trichlorobenzene 0743906118 01000 243 200 216 250Ave

12-Dichloroethane-d4 (Surr) 0320902638 01000 608 500 216 250Ave

Toluene-d8 (Surr) 11471167 01000 491 500 -18 250Ave

4-Bromofluorobenzene 0806308079 01000 499 500 -02 250Ave

FORM VII 8260B

10162012Page 102 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12abe08987d Report Date 12-Oct-2012 0132

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12abe08987dLab Smp Id CCV Inj Date 12-OCT-2012 0114 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info CCVMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12ab8260DE_09mMeth Date 12-Oct-2012 0132 ken Quant Type ISTDCal Date 12-OCT-2012 0114 Cal File e08987dAls bottle 12 Continuing Calibration SampleDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0894 (0249) 84911 200000 19

3 Chloromethane 50 1016 1016 (0283) 158694 200000 17

4 Vinyl Chloride 62 1022 1022 (0284) 130464 200000 17

6 Bromomethane 94 1181 1181 (0328) 82695 200000 25

5 Chloroethane 64 1236 1236 (0344) 64840 200000 23

7 Trichlorofluoromethane 101 1297 1297 (0361) 131020 200000 21

14 Freon TF 101 1565 1565 (0435) 114931 200000 27

15 11-Dichloroethene 96 1547 1547 (0430) 94244 200000 25

16 Acetone 58 1894 1894 (0527) 11208 200000 24

18 Carbon Disulfide 76 1565 1565 (0435) 401807 200000 23

27 Methyl Acetate 74 1961 1961 (0546) 24794 200000 23

22 Methylene Chloride 49 1857 1857 (0517) 179010 200000 20

28 MTBE 73 2022 2022 (0562) 392131 200000 22

25 trans-12-Dichloroethene 96 1943 1943 (0540) 118223 200000 23

30 11-Dichloroethane 63 2302 2302 (0640) 239419 200000 20

36 cis-12-Dichloroethene 96 2650 2650 (0737) 122782 200000 20

10162012Page 103 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12abe08987d Report Date 12-Oct-2012 0132

AMOUNTS

QUANT SIG CAL-AMT ON-COL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3077 3077 (0856) 21666 200000 25

42 Chloroform 83 2845 2845 (0791) 223324 200000 22

44 Cyclohexane 56 2784 2784 (0774) 195679 200000 18

43 111-Trichloroethane 97 2979 2979 (0829) 184861 200000 21

45 Carbon Tetrachloride 117 2930 2930 (0815) 148689 200000 22

48 Benzene 78 3260 3260 (0469) 501947 200000 19

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 408924 500000 61

49 12-Dichloroethane 62 3418 3418 (0951) 183231 200000 22

52 Fluorobenzene 96 3595 3595 (1000) 1274024 500000

54 Trichloroethene 95 3741 3741 (1041) 126518 200000 21

56 Methyl cyclohexane 83 3723 3723 (1036) 175700 200000 21

57 12-Dichloropropane 63 4192 4192 (1166) 135130 200000 19

68 Bromodichloromethane 83 4272 4272 (1188) 173147 200000 21

67 cis-13-Dichloropropene 75 4906 4906 (0705) 220680 200000 18

70 4-Methyl-2-Pentanone 43 5631 5631 (0810) 143892 200000 18

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1290179 500000 49

66 Toluene 91 5162 5162 (0742) 576151 200000 19

64 trans-13-Dichloropropene 75 5649 5649 (0812) 204342 200000 19

69 112-Trichloroethane 83 5820 5820 (0837) 95620 200000 19

71 Tetrachloroethene 166 5582 5582 (0803) 145404 200000 21

73 2-Hexanone 43 6680 6680 (0961) 109697 200000 18

74 Dibromochloromethane 129 6015 6015 (0865) 137888 200000 20

77 12-Dibromoethane 107 6265 6265 (0901) 117575 200000 20

78 Chlorobenzene-d5 117 6954 6954 (1000) 1125053 500000

79 Chlorobenzene 112 6972 6972 (1003) 395719 200000 20

81 Ethylbenzene 106 7064 7064 (1016) 208414 200000 19

82 m+p-Xylene 106 7277 7277 (1046) 528781 400000 40

84 o-Xylene 106 7856 7856 (1130) 260320 200000 20

85 Styrene 104 7942 7942 (1142) 445737 200000 20

86 Bromoform 173 7917 7917 (1139) 100375 200000 21

88 Isopropylbenzene 105 8344 8344 (1200) 647568 200000 20

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 536325 500000 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 154190 200000 18

105 13-Dichlorobenzene 146 10331 10331 (0987) 335032 200000 20

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 665092 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 347387 200000 20

111 12-Dichlorobenzene 146 11148 11148 (1065) 323155 200000 20

112 12-Dibromo-3-chloropropane 75 12233 12233 (1169) 27376 200000 18

114 124-Trichlorobenzene 180 12977 12977 (1240) 197894 200000 24

M 120 12-Dichloroethene (Total) 100 241005 400000 43

M 121 Xylene (Total) 100 789101 600000 59

10162012Page 104 of 323

Data File e08987d

Date 12-OCT-2012 0114

Client ID Instrument VOAMS5i

Sample Info CCV Operator GCMS VOAMS5

10162012Page 105 of 323

Data File chemVOAMS5i8260DE09-17-1217sep12be07834d Report Date 17-Sep-2012 0605

TestAmerica

Data file chemVOAMS5i8260DE09-17-1217sep12be07834dLab Smp Id BFB Inj Date 17-SEP-2012 0324 Operator VOAMS 1 Inst ID VOAMS5iSmp Info BFBMisc Info Comment Method chemVOAMS5i8260DE09-17-1217sep12bBFBDELmMeth Date 27-Feb-2012 1508 sylvanus Quant Type ISTDCal Date Cal File Als bottle 2 QC Sample BFBDil Factor 100000 Integrator HP RTE Compound Sublist allsubTarget Version 350 Sample Matrix WATERProcessing Host hpd2

Concentration Formula Amt DF Uf Vf VI CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorUf 100000 ng unit correction factorVf 100000 Volumetric correction factorVI 100000 Injection Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT (REL RT) MASS RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ==== ======== ======= ======= ============ =====

1 BFB CAS 460-00-4

2352 2600 (0000) 95 195072 000- 10000 10000

2352 2600 (0000) 50 42624 1500- 4000 2185

2352 2600 (0000) 75 102376 3000- 6000 5248

2352 2600 (0000) 96 12530 500- 900 642

2352 2600 (0000) 173 0 000- 200 000

2352 2600 (0000) 174 155200 5000- 10000 7956

2352 2600 (0000) 175 12902 500- 900 831

2352 2600 (0000) 176 148480 9500- 10100 9567

2352 2600 (0000) 177 9343 500- 900 629

-------------------------------------------------------------------------------

10162012Page 106 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

10162012Page 107 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

1 BFB

RELATIVE me ION ABUNDANCE CRITERIA ABUNDANCE

+-----+------------------------------------------+---------------------+| | | || 95 | Base Peak 100 relative abundance | 10000 || 50 | 1500 - 4000 of mass 95 | 2185 || 75 | 3000 - 6000 of mass 95 | 5248 || 96 | 500 - 900 of mass 95 | 642 || 173 | Less than 200 of mass 174 | 000 ( 000) || 174 | 5000 - 10000 of mass 95 | 7956 || 175 | 500 - 900 of mass 174 | 661 ( 831) || 176 | 9500 - 10100 of mass 174 | 7612 ( 9567) || 177 | 500 - 900 of mass 176 | 479 ( 629) |+-----+------------------------------------------+---------------------+

10162012Page 108 of 323

Data File e07834d

Date 17-SEP-2012 0324

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

Data File chemVOAMS5i8260DE09-17-1217sep12be07834dSpectrum Avg Scans 50-52 ( 235) Background Scan 46

Location of Maximum 9500Number of points 151

mz Y mz Y mz Y mz Y+------------------+------------------+------------------+------------------+| 3500 53 | 7700 1350 | 12300 88 | 17700 9343 || 3600 1914 | 7800 695 | 12400 252 | 17800 381 || 3700 12535 | 7900 5782 | 12500 148 | 18000 35 || 3800 10760 | 8000 1455 | 12700 282 | 18300 181 || 3900 3962 | 8100 5745 | 12800 338 | 18600 248 |+------------------+------------------+------------------+------------------+| 4100 387 | 8200 905 | 12900 75 | 18700 80 || 4400 707 | 8300 42 | 13000 926 | 18800 162 || 4500 1464 | 8500 229 | 13100 166 | 18900 142 || 4600 281 | 8600 239 | 13200 7 | 19100 151 || 4700 3334 | 8700 7427 | 13400 27 | 19200 54 |+------------------+------------------+------------------+------------------+| 4800 1491 | 8800 7774 | 13700 332 | 19300 44 || 4900 8401 | 9100 1022 | 13800 172 | 19400 110 || 5000 42624 | 9200 5845 | 14000 185 | 19600 46 || 5100 13346 | 9300 8046 | 14100 1957 | 19800 171 || 5200 539 | 9400 21672 | 14200 53 | 20000 162 |+------------------+------------------+------------------+------------------+| 5300 13 | 9500 195072 | 14300 1698 | 20200 62 || 5400 14 | 9600 12530 | 14400 295 | 20300 48 || 5500 230 | 9700 551 | 14500 186 | 20400 104 || 5600 3600 | 9900 79 | 14600 115 | 20500 34 || 5700 5500 | 10000 36 | 14700 156 | 20700 223 |+------------------+------------------+------------------+------------------+| 5800 113 | 10100 136 | 14800 465 | 20900 81 || 5900 106 | 10200 36 | 14900 118 | 21500 80 || 6000 1861 | 10300 237 | 15000 105 | 21900 89 || 6100 10125 | 10400 905 | 15300 459 | 22000 60 || 6200 9219 | 10500 514 | 15400 192 | 22600 84 |+------------------+------------------+------------------+------------------+| 6300 7541 | 10600 1054 | 15700 390 | 23000 188 || 6400 270 | 10700 304 | 16000 378 | 23100 74 || 6500 625 | 11000 398 | 16100 530 | 23500 107 || 6600 51 | 11100 151 | 16400 54 | 23900 43 || 6700 378 | 11200 121 | 16700 172 | 24600 123 |+------------------+------------------+------------------+------------------+| 6800 20496 | 11300 247 | 16800 205 | 24700 37 || 6900 19976 | 11500 421 | 16900 243 | 25000 57 || 7000 1570 | 11600 358 | 17000 351 | 25200 33 || 7200 740 | 11700 1343 | 17100 439 | 25500 46 || 7300 9006 | 11800 855 | 17200 227 | 26200 43 |+------------------+------------------+------------------+------------------+| 7400 34320 | 11900 733 | 17400 155200 | 26400 63 || 7500 102376 | 12100 68 | 17500 12902 | 26500 45 || 7600 8204 | 12200 77 | 17600 148480 | |+------------------+------------------+------------------+------------------+

10162012Page 109 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08975d Report Date 11-Oct-2012 2012

TestAmerica

Data file chemVOAMS5i8260DE09-17-1211oct12be08975dLab Smp Id BFB Inj Date 11-OCT-2012 2008 Operator VOAMS 1 Inst ID VOAMS5iSmp Info BFBMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12bBFBDELmMeth Date 27-Feb-2012 1508 sylvanus Quant Type ISTDCal Date Cal File Als bottle 2 QC Sample BFBDil Factor 100000 Integrator HP RTE Compound Sublist allsubTarget Version 350 Sample Matrix WATERProcessing Host hpd2

Concentration Formula Amt DF Uf Vf VI CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorUf 100000 ng unit correction factorVf 100000 Volumetric correction factorVI 100000 Injection Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT (REL RT) MASS RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ==== ======== ======= ======= ============ =====

1 BFB CAS 460-00-4

2352 2600 (0000) 95 135522 000- 10000 10000

2352 2600 (0000) 50 29541 1500- 4000 2180

2352 2600 (0000) 75 70179 3000- 6000 5178

2352 2600 (0000) 96 8846 500- 900 653

2352 2600 (0000) 173 896 000- 200 074

2352 2600 (0000) 174 121433 5000- 10000 8960

2352 2600 (0000) 175 9704 500- 900 799

2352 2600 (0000) 176 118148 9500- 10100 9729

2352 2600 (0000) 177 7241 500- 900 613

-------------------------------------------------------------------------------

10162012Page 110 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

10162012Page 111 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

1 BFB

RELATIVE me ION ABUNDANCE CRITERIA ABUNDANCE

+-----+------------------------------------------+---------------------+| | | || 95 | Base Peak 100 relative abundance | 10000 || 50 | 1500 - 4000 of mass 95 | 2180 || 75 | 3000 - 6000 of mass 95 | 5178 || 96 | 500 - 900 of mass 95 | 653 || 173 | Less than 200 of mass 174 | 066 ( 074) || 174 | 5000 - 10000 of mass 95 | 8960 || 175 | 500 - 900 of mass 174 | 716 ( 799) || 176 | 9500 - 10100 of mass 174 | 8718 ( 9729) || 177 | 500 - 900 of mass 176 | 534 ( 613) |+-----+------------------------------------------+---------------------+

10162012Page 112 of 323

Data File e08975d

Date 11-OCT-2012 2008

Client ID Instrument VOAMS5i

Sample Info BFB Operator VOAMS 1

Data File chemVOAMS5i8260DE09-17-1211oct12be08975dSpectrum Avg Scans 50-52 ( 235) Background Scan 46

Location of Maximum 9500Number of points 149

mz Y mz Y mz Y mz Y+------------------+------------------+------------------+------------------+| 3600 1294 | 7800 45 | 13100 382 | 18200 69 || 3700 8431 | 7900 4274 | 13200 84 | 18300 115 || 3800 6991 | 8000 1313 | 13400 26 | 18600 116 || 3900 2548 | 8100 3602 | 13500 465 | 18700 340 || 4000 550 | 8200 868 | 13600 63 | 18800 34 |+------------------+------------------+------------------+------------------+| 4100 253 | 8300 128 | 13700 225 | 18900 18 || 4200 100 | 8400 171 | 13900 69 | 19900 265 || 4400 553 | 8500 53 | 14000 115 | 20100 29 || 4500 1283 | 8700 5211 | 14100 1442 | 20400 84 || 4700 1587 | 8800 4550 | 14200 269 | 20500 33 |+------------------+------------------+------------------+------------------+| 4800 651 | 9100 642 | 14300 1465 | 20600 138 || 4900 5880 | 9200 3657 | 14400 23 | 20700 20 || 5000 29536 | 9300 6715 | 14500 103 | 20900 79 || 5100 8612 | 9400 15687 | 14700 151 | 21000 74 || 5200 396 | 9500 135488 | 14800 365 | 21100 1 |+------------------+------------------+------------------+------------------+| 5300 107 | 9600 8846 | 14900 429 | 21200 140 || 5500 726 | 9700 271 | 15100 54 | 21300 52 || 5600 1691 | 9800 1 | 15300 430 | 21400 189 || 5700 4463 | 10000 110 | 15400 385 | 22100 72 || 5800 245 | 10300 207 | 15500 1021 | 22200 35 |+------------------+------------------+------------------+------------------+| 5900 116 | 10400 668 | 15600 236 | 22400 188 || 6000 1281 | 10600 562 | 15700 473 | 22600 79 || 6100 6975 | 10700 159 | 15800 3 | 22800 39 || 6200 7260 | 11000 145 | 15900 410 | 23000 95 || 6300 5465 | 11100 68 | 16100 441 | 23300 189 |+------------------+------------------+------------------+------------------+| 6400 672 | 11200 80 | 16400 208 | 23400 42 || 6500 144 | 11300 261 | 16500 57 | 23500 36 || 6600 201 | 11600 813 | 17000 641 | 23600 58 || 6700 729 | 11700 882 | 17100 38 | 24100 103 || 6800 14333 | 11800 446 | 17200 338 | 24700 36 |+------------------+------------------+------------------+------------------+| 6900 14506 | 11900 1049 | 17300 896 | 25100 40 || 7000 1361 | 12000 38 | 17400 121432 | 25500 61 || 7200 782 | 12100 249 | 17500 9704 | 25600 33 || 7300 6586 | 12400 108 | 17600 118144 | 26000 59 || 7400 24016 | 12600 138 | 17700 7241 | 26500 78 |+------------------+------------------+------------------+------------------+| 7500 70176 | 12700 39 | 17900 19 | || 7600 5444 | 12900 479 | 18000 29 | || 7700 507 | 13000 702 | 18100 322 | |+------------------+------------------+------------------+------------------+

10162012Page 113 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 0060U71-55-6 111-Trichloroethane 0060

10 022U75-71-8 Dichlorodifluoromethane 022

10 010U74-87-3 Chloromethane 010

10 014U75-01-4 Vinyl chloride 014

10 018U74-83-9 Bromomethane 018

10 040U96-12-8 12-Dibromo-3-Chloropropane 040

10 021U95-50-1 12-Dichlorobenzene 021

10 015U75-69-4 Trichlorofluoromethane 015

10 0090U75-35-4 11-Dichloroethene 0090

10 0090U78-87-5 12-Dichloropropane 0090

10 0080U76-13-1 112-Trichloro-122-trifluoroethane

0080

50 27U67-64-1 Acetone 27

10 013U75-15-0 Carbon disulfide 013

20 034U79-20-9 Methyl acetate 034

10 018U75-09-2 Methylene Chloride 018

10 013U156-60-5 trans-12-Dichloroethene 013

10 020U124-48-1 Chlorodibromomethane 020

10 014U1634-04-4 Methyl tert-butyl ether 014

10 017U75-00-3 Chloroethane 017

10 013U75-34-3 11-Dichloroethane 013

10 018U156-59-2 cis-12-Dichloroethene 018

50 23U78-93-3 2-Butanone (MEK) 23

10 0080U67-66-3 Chloroform 0080

10 010U100-41-4 Ethylbenzene 010

10 016U110-82-7 Cyclohexane 016

10 0060U56-23-5 Carbon tetrachloride 0060

10 0080U71-43-2 Benzene 0080

10 019U107-06-2 12-Dichloroethane 019

10 0090U79-01-6 Trichloroethene 0090

10 014U108-87-2 Methylcyclohexane 014

10 012U75-27-4 Dichlorobromomethane 012

10 018U10061-01-5 cis-13-Dichloropropene 018

50 099U108-10-1 4-Methyl-2-pentanone (MIBK) 099

10 015U108-88-3 Toluene 015

10 024U10061-02-6 trans-13-Dichloropropene 024

FORM I 8260B

10162012Page 114 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 019U79-00-5 112-Trichloroethane 019

10 010U127-18-4 Tetrachloroethene 010

50 050U591-78-6 2-Hexanone 050

10 028U106-93-4 12-Dibromoethane 028

10 011U108-90-7 Chlorobenzene 011

30 036U1330-20-7 Xylenes Total 036

10 012U100-42-5 Styrene 012

10 019U75-25-2 Bromoform 019

10 0080U98-82-8 Isopropylbenzene 0080

10 016U79-34-5 1122-Tetrachloroethane 016

10 014U541-73-1 13-Dichlorobenzene 014

10 023U106-46-7 14-Dichlorobenzene 023

10 034U120-82-1 124-Trichlorobenzene 034

RECCAS NO LIMITSQSURROGATE

99 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

95 70-130460-00-4 4-Bromofluorobenzene

96 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 115 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

TENTATIVELY IDENTIFIED COMPOUNDS

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1316564

Matrix e08981dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2247

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

Number TICs Found TIC Result Total 00

QRTCOMPOUND NAME RESULTCAS NO

Tentatively Identified Compound None

FORM I-TIC 8260B

10162012Page 116 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08981d Report Date 12-Oct-2012 0041

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08981dLab Smp Id MB Inj Date 11-OCT-2012 2247 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info MBMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 6 QC Sample BLANKDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 381607 495518 50

52 Fluorobenzene 96 3595 3601 (1000) 1238441 500000

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1209056 482553 48

78 Chlorobenzene-d5 117 6954 6954 (1000) 1084553 500000

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 494380 477044 48

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 638826 500000

10162012Page 117 of 323

Data File e08981d

Date 11-OCT-2012 2247

Client ID Instrument VOAMS5i

Sample Info MB Operator GCMS VOAMS5

10162012Page 118 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1316563

Matrix e08977dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2113

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 006071-55-6 111-Trichloroethane 210

10 02275-71-8 Dichlorodifluoromethane 181

10 01074-87-3 Chloromethane 210

10 01475-01-4 Vinyl chloride 203

10 01874-83-9 Bromomethane 211

10 04096-12-8 12-Dibromo-3-Chloropropane 222

10 02195-50-1 12-Dichlorobenzene 209

10 01575-69-4 Trichlorofluoromethane 190

10 009075-35-4 11-Dichloroethene 223

10 009078-87-5 12-Dichloropropane 211

10 008076-13-1 112-Trichloro-122-trifluoroethane

203

50 2767-64-1 Acetone 250

10 01375-15-0 Carbon disulfide 218

20 03479-20-9 Methyl acetate 220

10 01875-09-2 Methylene Chloride 200

10 013156-60-5 trans-12-Dichloroethene 216

10 020124-48-1 Chlorodibromomethane 217

10 0141634-04-4 Methyl tert-butyl ether 207

10 01775-00-3 Chloroethane 201

10 01375-34-3 11-Dichloroethane 204

10 018156-59-2 cis-12-Dichloroethene 211

50 2378-93-3 2-Butanone (MEK) 214

10 008067-66-3 Chloroform 205

10 010100-41-4 Ethylbenzene 206

10 016110-82-7 Cyclohexane 208

10 006056-23-5 Carbon tetrachloride 211

10 008071-43-2 Benzene 212

10 019107-06-2 12-Dichloroethane 204

10 009079-01-6 Trichloroethene 212

10 014108-87-2 Methylcyclohexane 215

10 01275-27-4 Dichlorobromomethane 214

10 01810061-01-5 cis-13-Dichloropropene 216

50 099108-10-1 4-Methyl-2-pentanone (MIBK) 214

10 015108-88-3 Toluene 205

10 02410061-02-6 trans-13-Dichloropropene 215

FORM I 8260B

10162012Page 119 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1316563

Matrix e08977dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 1

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10112012 2113

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

10 01979-00-5 112-Trichloroethane 217

10 010127-18-4 Tetrachloroethene 210

50 050591-78-6 2-Hexanone 201

10 028106-93-4 12-Dibromoethane 215

10 011108-90-7 Chlorobenzene 206

30 0361330-20-7 Xylenes Total 612

10 012100-42-5 Styrene 207

10 01975-25-2 Bromoform 217

10 008098-82-8 Isopropylbenzene 207

10 01679-34-5 1122-Tetrachloroethane 210

10 014541-73-1 13-Dichlorobenzene 204

10 023106-46-7 14-Dichlorobenzene 204

10 034120-82-1 124-Trichlorobenzene 220

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

97 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 120 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08977d Report Date 11-Oct-2012 2301

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08977dLab Smp Id LCS Inj Date 11-OCT-2012 2113 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info LCSMisc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 2 QC Sample BSDil Factor 100000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 92905 180886 18

3 Chloromethane 50 1016 1016 (0283) 178821 210339 21

4 Vinyl Chloride 62 1022 1028 (0284) 146748 202753 20

6 Bromomethane 94 1181 1181 (0328) 88580 210689 21

5 Chloroethane 64 1236 1242 (0344) 67759 201399 20

7 Trichlorofluoromethane 101 1297 1303 (0361) 148657 190423 19

14 Freon TF 101 1565 1577 (0435) 106548 203057 20

15 11-Dichloroethene 96 1547 1553 (0430) 94737 223085 22

16 Acetone 58 1900 1894 (0529) 14083 249674 25

18 Carbon Disulfide 76 1565 1571 (0435) 377236 218062 22

27 Methyl Acetate 74 1961 1967 (0546) 21873 219755 22

22 Methylene Chloride 49 1858 1864 (0517) 180593 200499 20

28 MTBE 73 2022 2022 (0562) 363998 207251 21

25 trans-12-Dichloroethene 96 1943 1949 (0540) 119022 216004 22

30 11-Dichloroethane 63 2303 2309 (0640) 238759 204130 20

36 cis-12-Dichloroethene 96 2650 2656 (0737) 126688 211021 21

10162012Page 121 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08977d Report Date 11-Oct-2012 2301

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 20020 214276 21

42 Chloroform 83 2845 2845 (0791) 215227 205163 20

44 Cyclohexane 56 2778 2784 (0773) 186275 208395 21

43 111-Trichloroethane 97 2979 2985 (0829) 195599 210453 21

45 Carbon Tetrachloride 117 2931 2937 (0815) 156464 210644 21

48 Benzene 78 3260 3260 (0469) 500200 211727 21

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 391700 477589 48

49 12-Dichloroethane 62 3412 3418 (0949) 178793 204379 20

52 Fluorobenzene 96 3595 3601 (1000) 1318918 500000

54 Trichloroethene 95 3735 3741 (1039) 127803 211922 21

56 Methyl cyclohexane 83 3723 3729 (1036) 159134 214991 21

57 12-Dichloropropane 63 4192 4199 (1166) 134808 211159 21

68 Bromodichloromethane 83 4272 4272 (1188) 171399 214054 21

67 cis-13-Dichloropropene 75 4906 4912 (0705) 217526 216258 22

70 4-Methyl-2-Pentanone 43 5631 5625 (0810) 134218 214248 21

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1312817 495616 50

66 Toluene 91 5162 5162 (0742) 572353 205343 20

64 trans-13-Dichloropropene 75 5650 5649 (0812) 195539 215018 22

69 112-Trichloroethane 83 5820 5820 (0837) 92220 217218 22

71 Tetrachloroethene 166 5582 5582 (0803) 145712 209847 21

73 2-Hexanone 43 6680 6680 (0961) 96649 200980 20

74 Dibromochloromethane 129 6015 6021 (0865) 132048 217333 22

77 12-Dibromoethane 107 6259 6265 (0900) 113742 214758 21

78 Chlorobenzene-d5 117 6954 6954 (1000) 1146590 500000

79 Chlorobenzene 112 6972 6972 (1003) 392243 206030 21

81 Ethylbenzene 106 7064 7064 (1016) 206211 205716 20

82 m+p-Xylene 106 7277 7277 (1046) 519872 407882 41

84 o-Xylene 106 7856 7862 (1130) 254939 203845 20

85 Styrene 104 7942 7942 (1142) 437977 207191 21

86 Bromoform 173 7911 7911 (1138) 93696 217219 22

88 Isopropylbenzene 105 8344 8350 (1200) 637526 207206 21

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 538047 484974 48

92 1122-Tetrachloroethane 83 9112 9112 (0871) 147339 210261 21

105 13-Dichlorobenzene 146 10325 10331 (0987) 330263 203584 20

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 683882 500000

109 14-Dichlorobenzene 146 10484 10490 (1002) 343961 204369 20

111 12-Dichlorobenzene 146 11148 11148 (1065) 320073 208797 21

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 26198 222454 22

114 124-Trichlorobenzene 180 12977 12977 (1240) 189475 219787 22

M 120 12-Dichloroethene (Total) 100 245711 427025 43

M 121 Xylene (Total) 100 774811 611727 61

10162012Page 122 of 323

Data File e08977d

Date 11-OCT-2012 2113

Client ID Instrument VOAMS5i

Sample Info LCS Operator GCMS VOAMS5

10162012Page 123 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MS

Matrix e08985dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0027

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 03071-55-6 111-Trichloroethane 103

50 1175-71-8 Dichlorodifluoromethane 865

50 05074-87-3 Chloromethane 102

50 07075-01-4 Vinyl chloride 104

50 09074-83-9 Bromomethane 107

50 2096-12-8 12-Dibromo-3-Chloropropane 121

50 1195-50-1 12-Dichlorobenzene 107

50 07575-69-4 Trichlorofluoromethane 121

50 04575-35-4 11-Dichloroethene 108

50 04578-87-5 12-Dichloropropane 111

50 04076-13-1 112-Trichloro-122-trifluoroethane

102

25 1367-64-1 Acetone 986

50 06575-15-0 Carbon disulfide 113

10 1779-20-9 Methyl acetate 100

50 09075-09-2 Methylene Chloride 106

50 065156-60-5 trans-12-Dichloroethene 106

50 10124-48-1 Chlorodibromomethane 116

50 0701634-04-4 Methyl tert-butyl ether 114

50 08575-00-3 Chloroethane 116

50 06575-34-3 11-Dichloroethane 104

50 090156-59-2 cis-12-Dichloroethene 105

25 1278-93-3 2-Butanone (MEK) 111

50 04067-66-3 Chloroform 108

50 050100-41-4 Ethylbenzene 107

50 080110-82-7 Cyclohexane 108

50 03056-23-5 Carbon tetrachloride 105

50 04071-43-2 Benzene 106

50 095107-06-2 12-Dichloroethane 107

50 04579-01-6 Trichloroethene 107

50 070108-87-2 Methylcyclohexane 115

50 06075-27-4 Dichlorobromomethane 113

50 09010061-01-5 cis-13-Dichloropropene 109

25 50108-10-1 4-Methyl-2-pentanone (MIBK) 111

50 075108-88-3 Toluene 106

50 1210061-02-6 trans-13-Dichloropropene 113

FORM I 8260B

10162012Page 124 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MS

Matrix e08985dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0027

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 09579-00-5 112-Trichloroethane 112

50 050127-18-4 Tetrachloroethene 110

25 25591-78-6 2-Hexanone 109

50 14106-93-4 12-Dibromoethane 116

50 055108-90-7 Chlorobenzene 107

15 181330-20-7 Xylenes Total 318

50 060100-42-5 Styrene 107

50 09575-25-2 Bromoform 115

50 04098-82-8 Isopropylbenzene 107

50 08079-34-5 1122-Tetrachloroethane 115

50 070541-73-1 13-Dichlorobenzene 106

50 12106-46-7 14-Dichlorobenzene 106

50 17120-82-1 124-Trichlorobenzene 110

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

99 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 125 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08985d Report Date 12-Oct-2012 0117

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08985dLab Smp Id 460-45537-C-2 MS Inj Date 12-OCT-2012 0027 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-C-2 MS5Misc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 10 QC Sample MSDil Factor 500000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 500000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 83204 173010 86

3 Chloromethane 50 1016 1016 (0283) 161645 203059 100

4 Vinyl Chloride 62 1022 1028 (0284) 141501 208792 100

6 Bromomethane 94 1181 1181 (0328) 84568 214819 110

5 Chloroethane 64 1236 1242 (0344) 73104 232055 120

7 Trichlorofluoromethane 101 1297 1303 (0361) 177163 242363 120

14 Freon TF 101 1571 1577 (0437) 100496 204542 100

15 11-Dichloroethene 96 1553 1553 (0432) 86070 216451 110

16 Acetone 58 1894 1894 (0527) 10416 197218 99

18 Carbon Disulfide 76 1565 1571 (0435) 366514 226264 110

27 Methyl Acetate 74 1961 1967 (0546) 18655 200164 100

22 Methylene Chloride 49 1857 1864 (0517) 178536 211689 100

28 MTBE 73 2016 2022 (0561) 376182 228747 110

25 trans-12-Dichloroethene 96 1949 1949 (0542) 109215 211677 100

30 11-Dichloroethane 63 2309 2309 (0642) 226749 207039 100

36 cis-12-Dichloroethene 96 2650 2656 (0737) 118569 210921 100

10162012Page 126 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08985d Report Date 12-Oct-2012 0117

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 19396 221710 110

42 Chloroform 83 2845 2845 (0791) 213034 216876 110

44 Cyclohexane 56 2784 2784 (0774) 180984 216238 110

43 111-Trichloroethane 97 2979 2985 (0829) 179996 206829 100

45 Carbon Tetrachloride 117 2930 2937 (0815) 145570 209299 100

48 Benzene 78 3260 3260 (0469) 482493 212344 110

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 369860 481613 48

49 12-Dichloroethane 62 3418 3418 (0951) 175178 213858 110

52 Fluorobenzene 96 3595 3601 (1000) 1234975 500000

54 Trichloroethene 95 3741 3741 (1041) 121196 214627 110

56 Methyl cyclohexane 83 3729 3729 (1037) 158792 229110 110

57 12-Dichloropropane 63 4192 4199 (1166) 132380 221450 110

68 Bromodichloromethane 83 4272 4272 (1188) 168703 225007 110

67 cis-13-Dichloropropene 75 4906 4912 (0705) 211819 218949 110

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 133223 221106 110

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1260222 494657 49

66 Toluene 91 5162 5162 (0742) 566751 211409 100

64 trans-13-Dichloropropene 75 5649 5649 (0812) 197737 226072 110

69 112-Trichloroethane 83 5820 5820 (0837) 91872 224994 110

71 Tetrachloroethene 166 5582 5582 (0803) 147320 220590 110

73 2-Hexanone 43 6674 6680 (0960) 100809 217957 110

74 Dibromochloromethane 129 6015 6021 (0865) 135240 231427 120

77 12-Dibromoethane 107 6259 6265 (0900) 117784 231222 120

78 Chlorobenzene-d5 117 6954 6954 (1000) 1102789 500000

79 Chlorobenzene 112 6972 6972 (1003) 391979 214069 110

81 Ethylbenzene 106 7064 7064 (1016) 207079 214786 110

82 m+p-Xylene 106 7277 7277 (1046) 521861 425705 210

84 o-Xylene 106 7856 7862 (1130) 254032 211187 100

85 Styrene 104 7942 7942 (1142) 433507 213222 110

86 Bromoform 173 7911 7911 (1138) 95433 230033 120

88 Isopropylbenzene 105 8350 8350 (1201) 635772 214844 110

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 518047 497030 50

92 1122-Tetrachloroethane 83 9112 9112 (0871) 151817 230609 120

105 13-Dichlorobenzene 146 10325 10331 (0987) 322106 211348 100

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 642491 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 334190 211356 100

111 12-Dichlorobenzene 146 11148 11148 (1065) 308704 214355 110

112 12-Dibromo-3-chloropropane 75 12233 12234 (1169) 26873 242889 120(R)

114 124-Trichlorobenzene 180 12977 12977 (1240) 177853 219597 110

M 120 12-Dichloroethene (Total) 100 227784 422599 210

M 121 Xylene (Total) 100 775893 636892 320

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 127 of 323

Data File e08985d

Date 12-OCT-2012 0027

Client ID Instrument VOAMS5i

Sample Info 460-45537-C-2 MS5 Operator GCMS VOAMS5

10162012Page 128 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MSD

Matrix e08986dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0051

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 03071-55-6 111-Trichloroethane 106

50 1175-71-8 Dichlorodifluoromethane 896

50 05074-87-3 Chloromethane 101

50 07075-01-4 Vinyl chloride 105

50 09074-83-9 Bromomethane 105

50 2096-12-8 12-Dibromo-3-Chloropropane 121

50 1195-50-1 12-Dichlorobenzene 111

50 07575-69-4 Trichlorofluoromethane 997

50 04575-35-4 11-Dichloroethene 119

50 04578-87-5 12-Dichloropropane 110

50 04076-13-1 112-Trichloro-122-trifluoroethane

111

25 1367-64-1 Acetone 101

50 06575-15-0 Carbon disulfide 119

10 1779-20-9 Methyl acetate 101

50 09075-09-2 Methylene Chloride 106

50 065156-60-5 trans-12-Dichloroethene 108

50 10124-48-1 Chlorodibromomethane 118

50 0701634-04-4 Methyl tert-butyl ether 116

50 08575-00-3 Chloroethane 105

50 06575-34-3 11-Dichloroethane 111

50 090156-59-2 cis-12-Dichloroethene 109

25 1278-93-3 2-Butanone (MEK) 114

50 04067-66-3 Chloroform 113

50 050100-41-4 Ethylbenzene 111

50 080110-82-7 Cyclohexane 117

50 03056-23-5 Carbon tetrachloride 110

50 04071-43-2 Benzene 114

50 095107-06-2 12-Dichloroethane 109

50 04579-01-6 Trichloroethene 113

50 070108-87-2 Methylcyclohexane 121

50 06075-27-4 Dichlorobromomethane 116

50 09010061-01-5 cis-13-Dichloropropene 115

25 50108-10-1 4-Methyl-2-pentanone (MIBK) 114

50 075108-88-3 Toluene 111

50 1210061-02-6 trans-13-Dichloropropene 119

FORM I 8260B

10162012Page 129 of 323

FORM IForm 1GCMS VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2 MSD

Matrix e08986dLab File ID

Date Collected8260BAnalysis Method

Water

TestAmerica Edison

10052012 1230

Sample wtvol

Moisture

GC ColumnSoil Extract Vol

Dilution FactorSoil Aliquot Vol 5

Level (lowmed) Low

5(mL)

018(mm)

Date Analyzed 10122012 0051

IDRtx-VMS

Analysis Batch No 131656 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

50 09579-00-5 112-Trichloroethane 116

50 050127-18-4 Tetrachloroethene 116

25 25591-78-6 2-Hexanone 111

50 14106-93-4 12-Dibromoethane 117

50 055108-90-7 Chlorobenzene 111

15 181330-20-7 Xylenes Total 329

50 060100-42-5 Styrene 110

50 09575-25-2 Bromoform 114

50 04098-82-8 Isopropylbenzene 111

50 08079-34-5 1122-Tetrachloroethane 116

50 070541-73-1 13-Dichlorobenzene 110

50 12106-46-7 14-Dichlorobenzene 110

50 17120-82-1 124-Trichlorobenzene 119

RECCAS NO LIMITSQSURROGATE

96 70-13017060-07-0 12-Dichloroethane-d4 (Surr)

97 70-130460-00-4 4-Bromofluorobenzene

99 70-1302037-26-5 Toluene-d8 (Surr)

FORM I 8260B

10162012Page 130 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08986d Report Date 12-Oct-2012 0118

TestAmerica

VOLATILE ORGANIC COMPOUND ANALYSISData file chemVOAMS5i8260DE09-17-1211oct12be08986dLab Smp Id 460-45537-C-2 MSD Inj Date 12-OCT-2012 0051 Operator GCMS VOAMS5 Inst ID VOAMS5iSmp Info 460-45537-C-2 MSD5Misc Info Comment Method chemVOAMS5i8260DE09-17-1211oct12b8260DE_09mMeth Date 11-Oct-2012 2130 ken Quant Type ISTDCal Date 11-OCT-2012 2050 Cal File e08976dAls bottle 11 QC Sample MSDDil Factor 500000 Integrator HP RTE Compound Sublist HSLDELsubTarget Version 350 Processing Host hpd2

Concentration Formula Amt DF 5Vo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 500000 Dilution FactorVo 500000 Sample Volume

Cpnd Variable Local Compound Variable

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

2 Dichlorodifluoromethane 85 0894 0900 (0249) 90471 179208 90

3 Chloromethane 50 1016 1016 (0283) 169425 202751 100

4 Vinyl Chloride 62 1022 1028 (0284) 149176 209689 100

6 Bromomethane 94 1181 1181 (0328) 86595 209548 100

5 Chloroethane 64 1236 1242 (0344) 69668 210673 100

7 Trichlorofluoromethane 101 1297 1303 (0361) 152935 199307 100

14 Freon TF 101 1565 1577 (0435) 114134 221294 110

15 11-Dichloroethene 96 1547 1553 (0430) 98966 237094 120

16 Acetone 58 1900 1894 (0529) 11165 201386 100

18 Carbon Disulfide 76 1565 1571 (0435) 405349 238385 120

27 Methyl Acetate 74 1961 1967 (0546) 19684 201192 100

22 Methylene Chloride 49 1858 1864 (0517) 187993 212342 110

28 MTBE 73 2022 2022 (0562) 399850 231621 120(R)

25 trans-12-Dichloroethene 96 1943 1949 (0540) 117162 216323 110

30 11-Dichloroethane 63 2309 2309 (0642) 255983 222660 110

36 cis-12-Dichloroethene 96 2650 2656 (0737) 129220 218978 110

10162012Page 131 of 323

Data File chemVOAMS5i8260DE09-17-1211oct12be08986d Report Date 12-Oct-2012 0118

CONCENTRATIONS

QUANT SIG ON-COLUMN FINAL

Compounds MASS RT EXP RT REL RT RESPONSE ( ugL) ( ugL)

========================== ==== == ====== ====== ======== ======= =======

38 2-Butanone 72 3071 3077 (0854) 20938 227991 110

42 Chloroform 83 2845 2845 (0791) 233404 226357 110

44 Cyclohexane 56 2778 2784 (0773) 204751 233046 120

43 111-Trichloroethane 97 2979 2985 (0829) 194508 212915 110

45 Carbon Tetrachloride 117 2931 2937 (0815) 161111 220670 110

48 Benzene 78 3260 3260 (0469) 525066 227601 110

$ 47 12-Dichloroethane-d4 (SUR) 65 3363 3363 (0936) 386156 479012 48

49 12-Dichloroethane 62 3412 3418 (0949) 188223 218898 110

52 Fluorobenzene 96 3595 3601 (1000) 1296388 500000

54 Trichloroethene 95 3741 3741 (1041) 133629 225434 110

56 Methyl cyclohexane 83 3723 3729 (1036) 175741 241553 120

57 12-Dichloropropane 63 4192 4199 (1166) 138376 220515 110

68 Bromodichloromethane 83 4272 4272 (1188) 182026 231276 120

67 cis-13-Dichloropropene 75 4906 4912 (0705) 226245 230339 120

70 4-Methyl-2-Pentanone 43 5625 5625 (0809) 139423 227913 110

$ 65 Toluene-d8 (SUR) 98 5107 5107 (0734) 1279885 494812 49

66 Toluene 91 5162 5162 (0742) 602122 221221 110

64 trans-13-Dichloropropene 75 5650 5649 (0812) 211878 238592 120(R)

69 112-Trichloroethane 83 5820 5820 (0837) 95786 231047 120

71 Tetrachloroethene 166 5582 5582 (0803) 157152 231769 120

73 2-Hexanone 43 6680 6680 (0961) 103997 221464 110

74 Dibromochloromethane 129 6015 6021 (0865) 140562 236912 120

77 12-Dibromoethane 107 6259 6265 (0900) 120913 233791 120

78 Chlorobenzene-d5 117 6954 6954 (1000) 1119645 500000

79 Chlorobenzene 112 6972 6972 (1003) 411739 221475 110

81 Ethylbenzene 106 7064 7064 (1016) 216984 221672 110

82 m+p-Xylene 106 7277 7277 (1046) 549474 441482 220

84 o-Xylene 106 7856 7862 (1130) 265488 217389 110

85 Styrene 104 7942 7942 (1142) 452927 219420 110

86 Bromoform 173 7911 7911 (1138) 96039 228008 110

88 Isopropylbenzene 105 8344 8350 (1200) 668990 222665 110

$ 89 Bromofluorobenzene (SUR) 174 8710 8710 (0832) 517679 487311 49

92 1122-Tetrachloroethane 83 9112 9112 (0871) 155509 231763 120

105 13-Dichlorobenzene 146 10325 10331 (0987) 342279 220349 110

108 14-Dichlorobenzene-d4 152 10466 10466 (1000) 654839 500000

109 14-Dichlorobenzene 146 10490 10490 (1002) 355256 220442 110

111 12-Dichlorobenzene 146 11148 11148 (1065) 324646 221173 110

112 12-Dibromo-3-chloropropane 75 12234 12234 (1169) 27355 242581 120(R)

114 124-Trichlorobenzene 180 12977 12977 (1240) 196651 238228 120

M 120 12-Dichloroethene (Total) 100 246382 435302 220

M 121 Xylene (Total) 100 814963 658871 330

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 132 of 323

Data File e08986d

Date 12-OCT-2012 0051

Client ID Instrument VOAMS5i

Sample Info 460-45537-C-2 MSD5 Operator GCMS VOAMS5

10162012Page 133 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GCMS VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

VOAMS5

128076

Start Date

End Date 09172012 1616

09172012 0324

BFB 460-1280761 Rtx-VMS 018(mm)109172012 0324 e07834d

IC 460-1280762 Rtx-VMS 018(mm)109172012 0449 e07836d

IC 460-1280763 Rtx-VMS 018(mm)109172012 0536 e07838d

ICIS 460-1280764 Rtx-VMS 018(mm)109172012 0600 e07839d

IC 460-1280765 Rtx-VMS 018(mm)109172012 0623 e07840d

IC 460-1280766 Rtx-VMS 018(mm)109172012 0646 e07841d

IC 460-1280767 Rtx-VMS 018(mm)109172012 0710 e07842d

ZZZZZ Rtx-VMS 018(mm)109172012 0937

ZZZZZ Rtx-VMS 018(mm)109172012 1047

ZZZZZ Rtx-VMS 018(mm)109172012 1111

ZZZZZ Rtx-VMS 018(mm)109172012 1134

ZZZZZ Rtx-VMS 018(mm)109172012 1157

ZZZZZ Rtx-VMS 018(mm)509172012 1221

ZZZZZ Rtx-VMS 018(mm)509172012 1244

ZZZZZ Rtx-VMS 018(mm)109172012 1307

ZZZZZ Rtx-VMS 018(mm)109172012 1331

ZZZZZ Rtx-VMS 018(mm)109172012 1354

ZZZZZ Rtx-VMS 018(mm)109172012 1417

ZZZZZ Rtx-VMS 018(mm)109172012 1441

CCV 460-12807620 Rtx-VMS 018(mm)109172012 1616

8260B

10162012Page 134 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GCMS VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

VOAMS5

131656

Start Date

End Date 10122012 0114

10112012 2008

BFB 460-1316561 Rtx-VMS 018(mm)110112012 2008 e08975d

CCVIS 460-1316562 Rtx-VMS 018(mm)110112012 2050 e08976d

LCS 460-1316563 Rtx-VMS 018(mm)110112012 2113 e08977d

MB 460-1316564 Rtx-VMS 018(mm)110112012 2247 e08981d

460-45537-3 TB-17338-100512-253 Rtx-VMS 018(mm)110112012 2317 e08982d

460-45537-1 WC-17338-100512-MW14-MM-251

Rtx-VMS 018(mm)110112012 2341 e08983d

460-45537-2 WC-17338-100512-MW101-MM-252

Rtx-VMS 018(mm)110122012 0004 e08984d

460-45537-2 MS WC-17338-100512-MW101-MM-252 MS

Rtx-VMS 018(mm)510122012 0027 e08985d

460-45537-2 MSD WC-17338-100512-MW101-MM-252 MSD

Rtx-VMS 018(mm)510122012 0051 e08986d

CCV 460-13165610 Rtx-VMS 018(mm)110122012 0114 e08987d

8260B

10162012Page 135 of 323

10162012Page 136 of 323

10162012Page 137 of 323

10162012Page 138 of 323

10162012Page 139 of 323

Method 8082 -

DelawarePolychlorinated Biphenyls (PCBs)

(GC) by Method 8082 (Delaware)

10162012Page 140 of 323

FORM II

GC SEMI VOA SURROGATE RECOVERY

Lab Name Job No 460-45537-1

SDG No

Matrix Water Level Low

TestAmerica Edison

GC Column (1) ID (mm) GC Column (2) ID (mm)CLP-1 053 CLP-2 053

Lab Sample IDClient Sample ID DCB1 DCB2

460-45537-1WC-17338-100512-MW14-MM-251

82 83

460-45537-2WC-17338-100512-MW101-MM-252

52 50

MB 460-1309971-A

97 88

LCS 460-1309972-A

91 84

LCSD 460-1309973-A

108 99

QC LIMITSQC LIMITSDCB = DCB Decachlorobiphenyl 37-150

FORM II 8082

Column to be used to flag recovery values

10162012Page 141 of 323

GC SEMI VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vf479497dWater

Lab ID LCS 460-1309972-A Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

PCB-1016 500 507 71-126101

PCB-1260 500 557 73-130111

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 142 of 323

GC SEMI VOA LAB CONTROL SAMPLE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vr479497dWater

Lab ID LCS 460-1309972-A Client ID

TestAmerica Edison

REC

REC

QC

LIMITSCONCENTRATION

(ugL)

SPIKE

ADDED

(ugL)

LCS LCS

COMPOUND

PCB-1016 500 483 71-12697

PCB-1260 500 573 73-130115

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 143 of 323

GC SEMI VOA LAB CONTROL SAMPLE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vf479498dWater

Lab ID LCSD 460-1309973-A Client ID

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

LCSD LCSD

500 516 30 71-126PCB-1016 2103

500 583 30 73-130PCB-1260 5117

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 144 of 323

GC SEMI VOA LAB CONTROL SAMPLE DUPLICATE RECOVERY

FORM III

Job NoLab Name

SDG No

LevelMatrixMatrix

Low

460-45537-1

Lab File ID vr479498dWater

Lab ID LCSD 460-1309973-A Client ID

TestAmerica Edison

COMPOUND

SPIKE

ADDED CONCENTRATION

REC

RPD

QC LIMITS

RPD REC (ugL) (ugL)

LCSD LCSD

500 497 30 71-126PCB-1016 399

500 595 30 73-130PCB-1260 4119

FORM III 8082

Column to be used to flag recovery and RPD values

10162012Page 145 of 323

FORM IV

GC SEMI VOA METHOD BLANK SUMMARY

Lab Name

SDG No

Job No 460-45537-1TestAmerica Edison

Date Analyzed(1)

Instrument ID(1)

GC Column(1) ID

Instrument ID(2)

Date Extracted 10082012 0755

Date Analyzed(2)

GC Column(2) IDCLP-2053(mm) 053(mm)

PESTGC9

10082012 2208

Lab File ID(1) Lab File ID(2)

Matrix Water

vf479496d

Lab Sample ID MB 460-1309971-A

vr479496d

10082012 2208

PESTGC9

CLP-1

THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES

ANALYZED 2

DATEDATE

ANALYZED 1LAB SAMPLE IDCLIENT SAMPLE ID

LCS 460-1309972-A 10082012 2224 10082012 2224

LCSD 460-1309973-A 10082012 2239 10082012 2239

460-45537-1WC-17338-100512-MW14-MM-251

10092012 0029 10092012 0029

460-45537-2WC-17338-100512-MW101-MM-252

10092012 0045 10092012 0045

FORM IV 8082

10162012Page 146 of 323

GC SEMI VOA ANALYTICAL SEQUENCE

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVRT 460-1311372 Date Analyzed 10082012 1830

Lab File ID (Standard) vf479493d

Instrument ID PESTGC9 GC Column CLP-2 ID 053(mm)

Heated Purge (YN) N

Calibration ID 17840

THE ANALYTICAL SEQUENCE OF BLANKS SAMPLES STANDARDS MSMSDs AND LCSs IS GIVEN BELOW

RT

DCB

UPPER LIMIT

LOWER LIMIT

1159

1139

CONTINUING CALIBRATION SURROGATE 1149

LAB SAMPLE ID DATE ANALYZEDCLIENT SAMPLE ID LAB FILE ID

CCVRT 460-1311372 10082012 1830 1149vf479493d

MB 460-1309971-A 10082012 2208 1148vf479496d

LCS 460-1309972-A 10082012 2224 1148vf479497d

LCSD 460-1309973-A 10082012 2239 1148vf479498d

460-45537-1 10092012 0029 1149WC-17338-100512-MW14-MM-251

vf479505d

460-45537-2 10092012 0045 1149WC-17338-100512-MW101-MM-252

vf479506d

PIBLK 460-13113718 10092012 0131 1149vf479509d

CCV 460-13113719 10092012 0147 1149vf479510d

DCB = DCB Decachlorobiphenyl

DCB RT Limit = plusmn 01 minutes of surrogate RT

Column used to flag values outside QC limits

FORM VIII 8082

10162012Page 147 of 323

GC SEMI VOA ANALYTICAL SEQUENCE

Lab Name Job No

SDG No

FORM VIII

TestAmerica Edison 460-45537-1

Sample No CCVRT 460-1311372 Date Analyzed 10082012 1830

Lab File ID (Standard) vr479493d

Instrument ID PESTGC9 GC Column CLP-1 ID 053(mm)

Heated Purge (YN) N

Calibration ID 17839

THE ANALYTICAL SEQUENCE OF BLANKS SAMPLES STANDARDS MSMSDs AND LCSs IS GIVEN BELOW

RT

DCB

UPPER LIMIT

LOWER LIMIT

1071

1051

CONTINUING CALIBRATION SURROGATE 1061

LAB SAMPLE ID DATE ANALYZEDCLIENT SAMPLE ID LAB FILE ID

CCVRT 460-1311372 10082012 1830 1061vr479493d

MB 460-1309971-A 10082012 2208 1061vr479496d

LCS 460-1309972-A 10082012 2224 1061vr479497d

LCSD 460-1309973-A 10082012 2239 1061vr479498d

460-45537-1 10092012 0029 1061WC-17338-100512-MW14-MM-251

vr479505d

460-45537-2 10092012 0045 1061WC-17338-100512-MW101-MM-252

vr479506d

PIBLK 460-13113718 10092012 0131 1061vr479509d

CCV 460-13113719 10092012 0147 1061vr479510d

DCB = DCB Decachlorobiphenyl

DCB RT Limit = plusmn 01 minutes of surrogate RT

Column used to flag values outside QC limits

FORM VIII 8082

10162012Page 148 of 323

FORM XForm 1

Client Sample ID

Lab Name Job No

SDG No

Lab Sample ID LCS 460-1309972-A

Instrument ID (1) Instrument ID (2)

Date Analyzed (1) Date Analyzed (2)

GC Column (1) ID GC Column (2) ID

TestAmerica Edison 460-45537-1

IDENTIFICATION SUMMARYForm 1

053(mm) 053(mm)

10082012 2224 10082012 2224

PESTGC9 PESTGC9

CLP-1 CLP-2

ANALYTE COL PEAK RTRT WINDOW

FROM TO PEAK MEAN

CONCENTRATIONRPD

PCB-1016 1 1 206 201 215 473 483 47

2 250 246 260 494

3 275 271 285 530

4 310 306 320 501

5 330 326 340 520

6 369 361 375 302

7 401 397 411 541

8 419 412 426 505

2 1 293 289 303 525 507

2 360 357 371 562

3 404 401 415 567

4 444 441 455 558

5 468 465 479 594

6 518 509 523 402

7 557 547 561 259

8 571 568 582 584

PCB-1260 1 1 605 600 614 554 573 28

2 650 645 659 558

3 694 689 703 581

4 714 709 723 548

5 758 753 767 565

6 886 882 896 559

7 908 904 918 619

8 1014 1008 1022 600

2 1 771 769 783 600 557

2 817 814 828 594

3 903 901 915 625

4 928 926 940 622

5 941 938 952 643

6 986 983 997 612

7 1062 1055 1069 212

8 1106 1102 1116 550

FORM X 8082

10162012Page 149 of 323

FORM XForm 1

Client Sample ID

Lab Name Job No

SDG No

Lab Sample ID LCSD 460-1309973-A

Instrument ID (1) Instrument ID (2)

Date Analyzed (1) Date Analyzed (2)

GC Column (1) ID GC Column (2) ID

TestAmerica Edison 460-45537-1

IDENTIFICATION SUMMARYForm 1

053(mm) 053(mm)

10082012 2239 10082012 2239

PESTGC9 PESTGC9

CLP-1 CLP-2

ANALYTE COL PEAK RTRT WINDOW

FROM TO PEAK MEAN

CONCENTRATIONRPD

PCB-1016 1 1 206 201 215 483 497 38

2 250 246 260 505

3 275 271 285 542

4 310 306 320 510

5 330 326 340 529

6 368 361 375 369

7 401 397 411 549

8 419 412 426 491

2 1 292 289 303 535 516

2 359 357 371 574

3 404 401 415 572

4 443 441 455 572

5 468 465 479 606

6 518 509 523 407

7 557 547 561 267

8 571 568 582 599

PCB-1260 1 1 605 600 614 565 595 19

2 650 645 659 571

3 694 689 703 595

4 714 709 723 563

5 757 753 767 585

6 886 882 896 582

7 908 904 918 656

8 1014 1008 1022 639

2 1 771 769 783 615 583

2 816 814 828 610

3 902 901 915 645

4 928 926 940 648

5 940 938 952 669

6 986 983 997 637

7 1062 1055 1069 253

8 1106 1102 1116 590

FORM X 8082

10162012Page 150 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix vf479505dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1000

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0029

5(mL)

Sample wtvol 980(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

83 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 151 of 323

Data File vf479505d Report Date 09-Oct-2012 0313

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479505dLab Smp Id 460-45537-E-1-B Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0029 Operator Inst ID PESTGC9iSmp Info 460-45537-E-1-BMisc Info 460-45537-E-1-BComment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 35 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 98000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11489 11515 -0026 22061081 829479 042 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 152 of 323

Data File vf479505d

Date 09-OCT-2012 0029

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-1-B Operator

10162012Page 153 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW14-MM-2

SDG No

460-45537-1

Lab Sample ID 460-45537-1

Matrix vr479505dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1000

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0029

5(mL)

Sample wtvol 980(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

051 013U12674-11-2 PCB-1016 013

051 029U11104-28-2 PCB-1221 029

051 012U11141-16-5 PCB-1232 012

051 012U53469-21-9 PCB-1242 012

051 024U12672-29-6 PCB-1248 024

051 017U11097-69-1 PCB-1254 017

051 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

82 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 154 of 323

Data File vr479505d Report Date 09-Oct-2012 0303

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479505dLab Smp Id 460-45537-E-1-B Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0029 Operator Inst ID PESTGC9iSmp Info 460-45537-E-1-BMisc Info 460-45537-E-1-BComment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 35 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 98000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 38407031 815954 042 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 155 of 323

Data File vr479505d

Date 09-OCT-2012 0029

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-1-B Operator

10162012Page 156 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix vf479506dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1230

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0045

5(mL)

Sample wtvol 990(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

50 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 157 of 323

Data File vf479506d Report Date 09-Oct-2012 0322

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479506dLab Smp Id 460-45537-E-2-A Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0045 Operator Inst ID PESTGC9iSmp Info 460-45537-E-2-AMisc Info 460-45537-E-2-AComment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 36 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 99000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11487 11515 -0028 13346591 501821 025 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 158 of 323

Data File vf479506d

Date 09-OCT-2012 0045

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-2-A Operator

10162012Page 159 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

WC-17338-100512-MW101-MM-

SDG No

460-45537-1

Lab Sample ID 460-45537-2

Matrix vr479506dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

10052012 1230

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10092012 0045

5(mL)

Sample wtvol 990(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

051 013U12674-11-2 PCB-1016 013

051 028U11104-28-2 PCB-1221 028

051 012U11141-16-5 PCB-1232 012

051 012U53469-21-9 PCB-1242 012

051 024U12672-29-6 PCB-1248 024

051 017U11097-69-1 PCB-1254 017

051 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

52 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 160 of 323

Data File vr479506d Page 1 Report Date 09-Oct-2012 0322

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479506dLab Smp Id 460-45537-E-2-A Client Smp ID WC-17338-100512-MW1Inj Date 09-OCT-2012 0045 Operator Inst ID PESTGC9iSmp Info 460-45537-E-2-AMisc Info 460-45537-E-2-AComment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 36 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix WATERProcessing Host hpd3

Concentration Formula Amt DF VtVo CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 500000 Volume of final extract (mL)Vo 99000000 Volume of sample extracted (mL)

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 24675227 524223 026 8000- 12000 10000

-------------------------------------------------------------------------------

10162012Page 161 of 323

Data File vr479506d

Date 09-OCT-2012 0045

Client ID WC-17338-100512-MW1 Instrument PESTGC9i

Sample Info 460-45537-E-2-A Operator

10162012Page 162 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vf479200dLevel 2 IC 460-1299268 vf479201dLevel 3 IC 460-1299269 vf479202dLevel 4 IC 460-12992610 vf479203dLevel 5 IC 460-12992611 vf479204d

ANALYTE LVL 1 LVL 2 LVL 3 LVL 4 LVL 5 AVG RTRT WINDOW

PCB-1016 Peak 1 29602891 - 30312960 2960 2961 2959 2959PCB-1016 Peak 2 36403571 - 37113640 3640 3641 3639 3640PCB-1016 Peak 3 40844015 - 41554084 4084 4085 4083 4083PCB-1016 Peak 4 44774409 - 45494477 4477 4479 4477 4476PCB-1016 Peak 5 47224652 - 47924722 4722 4722 4722 4722PCB-1016 Peak 6 51575088 - 52285157 5158 5158 5157 5157PCB-1016 Peak 7 55425472 - 56125542 5543 5542 5542 5542PCB-1016 Peak 8 57515682 - 58225751 5751 5752 5751 5751PCB-1260 Peak 1 77567686 - 78267756 7756 7756 7756 7755PCB-1260 Peak 2 82158145 - 82858216 8215 8215 8215 8215PCB-1260 Peak 3 90839014 - 91549084 9084 9084 9083 9082PCB-1260 Peak 4 93329262 - 94029332 9332 9332 9332 9331PCB-1260 Peak 5 94549384 - 95249454 9454 9454 9454 9453PCB-1260 Peak 6 99019831 - 99719901 9901 9901 9901 9901PCB-1260 Peak 7 1061710546 - 1068610617 10617 10616 10617 10616PCB-1260 Peak 8 1108611016 - 1115611087 11087 11086 11084 11085DCB Decachlorobiphenyl 1151511415 - 1161511518 11520 11515 11510 11512

FORM VI 8082 10162012Page 163 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1299267 vf479200d2Level IC 460-1299268 vf479201d3Level IC 460-1299269 vf479202d4Level IC 460-12992610 vf479203d5Level IC 460-12992611 vf479204d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1016 Peak 1 Ave 155 20012858 10484 96475 9762186122

102726535

PCB-1016 Peak 2 Ave 122 20025248 21181 20808 2014318185

211130015

PCB-1016 Peak 3 Ave 124 20010359 90007 83526 8441074163

871400841

PCB-1016 Peak 4 Ave 130 20045579 38951 35291 3591632814

377100165

PCB-1016 Peak 5 Ave 129 20019485 17677 14821 1595214340

164548979

PCB-1016 Peak 6 Ave 171 20012410 10306 89543 9039281426

977025128

PCB-1016 Peak 7 Ave 161 20015097 12427 11165 1121510046

119900052

PCB-1016 Peak 8 Ave 121 20014456 12522 11609 1161310532

121463746

PCB-1260 Peak 1 Ave 165 20028165 22320 20852 2059718598

221063931

PCB-1260 Peak 2 Ave 173 20032398 25230 23518 2315121164

250922627

PCB-1260 Peak 3 Ave 101 20042792 37584 35706 3549332757

368665853

PCB-1260 Peak 4 Ave 114 20019125 16727 15681 1547514194

162405856

PCB-1260 Peak 5 Ave 71 20097407 90339 86445 8609680436

881445133

PCB-1260 Peak 6 Ave 116 20020218 16837 16387 1620514980

169255417

PCB-1260 Peak 7 Ave 115 20025044 20516 20530 2080218426

210635761

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 164 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1260 Peak 8 Ave 114 20092729 80982 75320 7482969000

785718832

DCB Decachlorobiphenyl Ave 104 200306013 281530 257456 246481238335

265963086

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 165 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17840Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vf479200dLevel 2 IC 460-1299268 vf479201dLevel 3 IC 460-1299269 vf479202dLevel 4 IC 460-12992610 vf479203dLevel 5 IC 460-12992611 vf479204d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1LVL 2 LVL 2LVL 3 LVL 3LVL 4 LVL 4LVL 5 LVL 5

PCB-1016 Peak 1 Ave 1285777 5241842 9647477 14643185 21530533 100 500 1000 1500 2500PCB-1016 Peak 2 Ave 2524804 10590544 20808307 30213965 45462323 100 500 1000 1500 2500PCB-1016 Peak 3 Ave 1035943 4500373 8352607 12661468 18540701 100 500 1000 1500 2500PCB-1016 Peak 4 Ave 4557926 19475271 35290615 53874092 82034010 100 500 1000 1500 2500PCB-1016 Peak 5 Ave 1948484 8838480 14821328 23927783 35848765 100 500 1000 1500 2500PCB-1016 Peak 6 Ave 1240957 5152808 8954270 13558761 20356566 100 500 1000 1500 2500PCB-1016 Peak 7 Ave 1509707 6213265 11165134 16822458 25115800 100 500 1000 1500 2500PCB-1016 Peak 8 Ave 1445572 6260864 11609452 17418946 26330856 100 500 1000 1500 2500PCB-1260 Peak 1 Ave 2816529 11159859 20851674 30895442 46495806 100 500 1000 1500 2500PCB-1260 Peak 2 Ave 3239811 12615093 23518487 34726449 52908911 100 500 1000 1500 2500PCB-1260 Peak 3 Ave 4279245 18792136 35705636 53240044 81893015 100 500 1000 1500 2500PCB-1260 Peak 4 Ave 1912505 8363664 15681452 23213228 35484032 100 500 1000 1500 2500PCB-1260 Peak 5 Ave 974074 4516956 8644462 12914338 20108960 100 500 1000 1500 2500PCB-1260 Peak 6 Ave 2021814 8418625 16386843 24307809 37450674 100 500 1000 1500 2500PCB-1260 Peak 7 Ave 2504445 10257895 20530020 31202581 46064749 100 500 1000 1500 2500PCB-1260 Peak 8 Ave 927285 4049088 7531982 11224374 17250044 100 500 1000 1500 2500DCB Decachlorobiphenyl Ave 7650320 14076513 25745578 36972164 47667099 250 500 100 150 200

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 166 of 323

Data File vf479200d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479200dLab Smp Id IC-SG1660L1_00013 Inj Date 30-SEP-2012 1704 Operator Inst ID PESTGC9iSmp Info ic-SG1660L1_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1704 Cal File vf479200dAls bottle 7 Calibration Sample Level 1Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2960 2961 -0001 1285777 100000 120 8000- 12000 10000

3640 3641 -0001 2524804 100000 120 15709- 23564 19636

4084 4085 -0001 1035943 100000 120 6446- 9668 8057

4477 4479 -0002 4557926 100000 120 28359- 42539 35449

4722 4722 0000 1948484 100000 120 12123- 18185 15154

5157 5158 -0001 1240957 100000 130 7721- 11582 9651

5542 5542 0000 1509707 100000 120 9393- 14090 11742

5751 5752 -0001 1445572 100000 120 8994- 13491 11243

Average of Peak Amounts = 122

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 2816529 100000 130 8000- 12000 10000(M)

10162012Page 167 of 323

Data File vf479200d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8216 8215 0001 3239811 100000 130 9202- 13803 11503

9084 9084 0000 4279245 100000 120 12155- 18232 15193

9332 9332 0000 1912505 100000 120 5432- 8148 6790

9454 9454 0000 974074 100000 110 2767- 4150 3458

9901 9901 0000 2021814 100000 120 5743- 8614 7178

10617 10616 0001 2504445 100000 120 7114- 10670 8892

11087 11086 0001 927285 100000 120 2634- 3951 3292

Average of Peak Amounts = 120

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11518 11515 0003 7650320 250000 29 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 168 of 323

Data File vf479200d

Date 30-SEP-2012 1704

Client ID Instrument PESTGC9i

Sample Info ic-SG1660L1_00013 Operator

10162012Page 169 of 323

Data File vf479201d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479201dLab Smp Id IC-SG1660L2_00013 Inj Date 30-SEP-2012 1720 Operator Inst ID PESTGC9iSmp Info SG1660L2_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1720 Cal File vf479201dAls bottle 8 Calibration Sample Level 2Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2960 2961 -0001 5241842 500000 510 8000- 12000 10000

3640 3641 -0001 10590544 500000 500 16163- 24245 20204

4084 4085 -0001 4500373 500000 520 6868- 10303 8585

4477 4479 -0002 19475271 500000 520 29723- 44584 37153

4722 4722 0000 8838480 500000 540 13489- 20234 16861

5158 5158 0000 5152808 500000 530 7864- 11796 9830

5543 5542 0001 6213265 500000 520 9483- 14224 11853

5751 5752 -0001 6260864 500000 520 9555- 14333 11944

Average of Peak Amounts = 518

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 11159859 500000 500 8000- 12000 10000(M)

10162012Page 170 of 323

Data File vf479201d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 12615093 500000 500 9043- 13565 11304

9084 9084 0000 18792136 500000 510 13471- 20207 16839

9332 9332 0000 8363664 500000 510 5996- 8993 7494

9454 9454 0000 4516956 500000 510 3238- 4857 4048

9901 9901 0000 8418625 500000 500 6035- 9052 7544

10617 10616 0001 10257895 500000 490 7353- 11030 9192

11087 11086 0001 4049088 500000 520 2903- 4354 3628

Average of Peak Amounts = 506

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11520 11515 0005 14076513 500000 53 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 171 of 323

Data File vf479201d

Date 30-SEP-2012 1720

Client ID Instrument PESTGC9i

Sample Info SG1660L2_00013 Operator

10162012Page 172 of 323

Data File vf479202d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479202dLab Smp Id IC-SG1660L3_00019 Inj Date 30-SEP-2012 1735 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 9 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2961 2961 0000 9647477 100000 940 8000- 12000 10000

3641 3641 0000 20808307 100000 980 17255- 25882 21569

4085 4085 0000 8352607 100000 960 6926- 10389 8658

4479 4479 0000 35290615 100000 940 29264- 43896 36580

4722 4722 0000 14821328 100000 900 12290- 18435 15363

5158 5158 0000 8954270 100000 920 7425- 11138 9281

5542 5542 0000 11165134 100000 930 9258- 13888 11573

5752 5752 0000 11609452 100000 960 9627- 14440 12034

Average of Peak Amounts = 940

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 20851674 100000 940 8000- 12000 10000(M)

10162012Page 173 of 323

Data File vf479202d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 23518487 100000 940 9023- 13535 11279

9084 9084 0000 35705636 100000 970 13699- 20548 17124

9332 9332 0000 15681452 100000 960 6016- 9025 7520

9454 9454 0000 8644462 100000 980 3317- 4975 4146

9901 9901 0000 16386843 100000 970 6287- 9431 7859

10616 10616 0000 20530020 100000 970 7877- 11815 9846

11086 11086 0000 7531982 100000 960 2890- 4335 3612

Average of Peak Amounts = 962

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11515 11515 0000 25745578 100000 97 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 174 of 323

Data File vf479202d

Date 30-SEP-2012 1735

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 175 of 323

Data File vf479203d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479203dLab Smp Id IC-SG1660L4_00013 Inj Date 30-SEP-2012 1751 Operator Inst ID PESTGC9iSmp Info SG1660L4_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1751 Cal File vf479203dAls bottle 10 Calibration Sample Level 4Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2959 2961 -0002 14643185 150000 1400 8000- 12000 10000

3639 3641 -0002 30213965 150000 1400 16507- 24760 20633

4083 4085 -0002 12661468 150000 1400 6917- 10376 8647

4477 4479 -0002 53874092 150000 1400 29433- 44149 36791

4722 4722 0000 23927783 150000 1400 13072- 19609 16341

5157 5158 -0001 13558761 150000 1400 7408- 11111 9259

5542 5542 0000 16822458 150000 1400 9191- 13786 11488

5751 5752 -0001 17418946 150000 1400 9516- 14275 11896

Average of Peak Amounts = 143e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7756 7756 0000 30895442 150000 1400 8000- 12000 10000(M)

10162012Page 176 of 323

Data File vf479203d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 34726449 150000 1400 8992- 13488 11240

9083 9084 -0001 53240044 150000 1400 13786- 20679 17232

9332 9332 0000 23213228 150000 1400 6011- 9016 7513

9454 9454 0000 12914338 150000 1500 3344- 5016 4180

9901 9901 0000 24307809 150000 1400 6294- 9441 7868

10617 10616 0001 31202581 150000 1500 8080- 12119 10099

11084 11086 -0002 11224374 150000 1400 2906- 4360 3633

Average of Peak Amounts = 143e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11510 11515 -0005 36972164 150000 140 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 177 of 323

Data File vf479203d

Date 30-SEP-2012 1751

Client ID Instrument PESTGC9i

Sample Info SG1660L4_00013 Operator

10162012Page 178 of 323

Data File vf479204d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479204dLab Smp Id IC-SG1660L5_00013 Inj Date 30-SEP-2012 1807 Operator Inst ID PESTGC9iSmp Info SG1660L5_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1807 Cal File vf479204dAls bottle 11 Calibration Sample Level 5Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2959 2961 -0002 21530533 250000 2100 8000- 12000 10000

3640 3641 -0001 45462323 250000 2200 16892- 25338 21115

4083 4085 -0002 18540701 250000 2100 6889- 10334 8611

4476 4479 -0003 82034010 250000 2200 30481- 45721 38101

4722 4722 0000 35848765 250000 2200 13320- 19980 16650

5157 5158 -0001 20356566 250000 2100 7564- 11346 9455

5542 5542 0000 25115800 250000 2100 9332- 13998 11665

5751 5752 -0001 26330856 250000 2200 9784- 14675 12230

Average of Peak Amounts = 213e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7755 7756 -0001 46495806 250000 2100 8000- 12000 10000(M)

10162012Page 179 of 323

Data File vf479204d Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8215 8215 0000 52908911 250000 2100 9103- 13655 11379

9082 9084 -0002 81893015 250000 2200 14090- 21136 17613

9331 9332 -0001 35484032 250000 2200 6105- 9158 7632

9453 9454 -0001 20108960 250000 2300 3460- 5190 4325

9901 9901 0000 37450674 250000 2200 6444- 9666 8055

10616 10616 0000 46064749 250000 2200 7926- 11889 9907

11085 11086 -0001 17250044 250000 2200 2968- 4452 3710

Average of Peak Amounts = 219e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11512 11515 -0003 47667099 200000 180 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 180 of 323

Data File vf479204d

Date 30-SEP-2012 1807

Client ID Instrument PESTGC9i

Sample Info SG1660L5_00013 Operator

10162012Page 181 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vr479200dLevel 2 IC 460-1299268 vr479201dLevel 3 IC 460-1299269 vr479202dLevel 4 IC 460-12992610 vr479203dLevel 5 IC 460-12992611 vr479204d

ANALYTE LVL 1 LVL 2 LVL 3 LVL 4 LVL 5 AVG RTRT WINDOW

PCB-1016 Peak 1 20842015 - 21552085 2084 2085 2083 2084PCB-1016 Peak 2 25272457 - 25972527 2526 2527 2527 2526PCB-1016 Peak 3 27762707 - 28472777 2776 2777 2775 2775PCB-1016 Peak 4 31283060 - 32003128 3128 3130 3128 3127PCB-1016 Peak 5 33293260 - 34003329 3329 3330 3328 3328PCB-1016 Peak 6 36823615 - 37553682 3682 3685 3683 3681PCB-1016 Peak 7 40433973 - 41134042 4043 4043 4042 4043PCB-1016 Peak 8 41904121 - 42614190 4190 4191 4188 4190PCB-1260 Peak 1 60716002 - 61426072 6072 6072 6071 6071PCB-1260 Peak 2 65226452 - 65926522 6523 6522 6522 6521PCB-1260 Peak 3 69646894 - 70346964 6965 6964 6963 6964PCB-1260 Peak 4 71647095 - 72357165 7165 7165 7164 7164PCB-1260 Peak 5 76027532 - 76727602 7603 7602 7602 7601PCB-1260 Peak 6 88938823 - 89638893 8894 8893 8893 8892PCB-1260 Peak 7 91159045 - 91859115 9115 9115 9115 9114PCB-1260 Peak 8 1015310083 - 1022310153 10154 10153 10153 10153DCB Decachlorobiphenyl 1062410524 - 1072410625 10625 10624 10624 10624

FORM VI 8082 10162012Page 182 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-1299267 vr479200d2Level IC 460-1299268 vr479201d3Level IC 460-1299269 vr479202d4Level IC 460-12992610 vr479203d5Level IC 460-12992611 vr479204d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1016 Peak 1 Ave 197 20021391 15827 14690 1421213626

159493236

PCB-1016 Peak 2 Ave 165 20034434 28377 25503 2514722693

272309984

PCB-1016 Peak 3 Ave 77 20020149 18502 16986 1713716990

179529604

PCB-1016 Peak 4 Ave 163 20075334 61344 55787 5498850020

594947119

PCB-1016 Peak 5 Ave 111 20026774 23733 21963 2197020028

228936643

PCB-1016 Peak 6 Ave 186 20030865 24479 22517 2109919526

236972316

PCB-1016 Peak 7 Ave 97 20025842 23012 21540 2153920131

224127747

PCB-1016 Peak 8 Ave 151 20012619 94689 86303 1057294995

101578271

PCB-1260 Peak 1 Ave 163 20041532 33110 31025 3015327565

326771001

PCB-1260 Peak 2 Ave 177 20078411 60909 57128 5539650491

604671657

PCB-1260 Peak 3 Ave 138 20068452 55082 53236 5187948612

554520757

PCB-1260 Peak 4 Ave 154 20037971 30462 28586 2772626073

301638112

PCB-1260 Peak 5 Ave 148 20034082 26592 25567 2477624302

270637128

PCB-1260 Peak 6 Ave 81 20038982 34673 33173 3331131697

343672090

PCB-1260 Peak 7 Ave 66 20023297 21847 20031 2012320512

211620048

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 183 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 4LVL 3LVL 2LVL 1

CFANALYTE MIN CF

LVL 5

PCB-1260 Peak 8 Ave 59 20018824 17382 16914 1709216013

172450198

DCB Decachlorobiphenyl Ave 109 200544588 499440 455074 438703415700

470701073

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 184 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17839Calibration Start Date Calibration End Date09302012 1704

N

09302012 1807

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-1299267 vr479200dLevel 2 IC 460-1299268 vr479201dLevel 3 IC 460-1299269 vr479202dLevel 4 IC 460-12992610 vr479203dLevel 5 IC 460-12992611 vr479204d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1LVL 2 LVL 2LVL 3 LVL 3LVL 4 LVL 4LVL 5 LVL 5

PCB-1016 Peak 1 Ave 2139086 7913738 14690255 21317999 34065069 100 500 1000 1500 2500PCB-1016 Peak 2 Ave 3443416 14188692 25503333 37720095 56733462 100 500 1000 1500 2500PCB-1016 Peak 3 Ave 2014938 9251204 16986172 25705034 42475382 100 500 1000 1500 2500PCB-1016 Peak 4 Ave 7533379 30672168 55786970 82482485 125050351 100 500 1000 1500 2500PCB-1016 Peak 5 Ave 2677413 11866731 21962918 32955239 50069130 100 500 1000 1500 2500PCB-1016 Peak 6 Ave 3086462 12239557 22517485 31648230 48815297 100 500 1000 1500 2500PCB-1016 Peak 7 Ave 2584175 11505820 21540272 32309208 50326849 100 500 1000 1500 2500PCB-1016 Peak 8 Ave 1261883 4734436 8630325 15857466 23748661 100 500 1000 1500 2500PCB-1260 Peak 1 Ave 4153239 16554914 31025367 45229464 68912349 100 500 1000 1500 2500PCB-1260 Peak 2 Ave 7841143 30454619 57128111 83094008 126227611 100 500 1000 1500 2500PCB-1260 Peak 3 Ave 6845178 27541094 53235986 77818190 121529078 100 500 1000 1500 2500PCB-1260 Peak 4 Ave 3797116 15230911 28586487 41589423 65183263 100 500 1000 1500 2500PCB-1260 Peak 5 Ave 3408191 13295973 25567248 37163734 60754093 100 500 1000 1500 2500PCB-1260 Peak 6 Ave 3898216 17336408 33172625 49966572 79243490 100 500 1000 1500 2500PCB-1260 Peak 7 Ave 2329661 10923449 20031237 30184937 51279969 100 500 1000 1500 2500PCB-1260 Peak 8 Ave 1882356 8691093 16914378 25637846 40032694 100 500 1000 1500 2500DCB Decachlorobiphenyl Ave 13614701 24972013 45507407 65805444 83140007 250 500 100 150 200

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 185 of 323

Data File vr479200d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479200dLab Smp Id IC-SG1660L1_00013 Inj Date 30-SEP-2012 1704 Operator Inst ID PESTGC9iSmp Info ic-SG1660L1_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 7 Calibration Sample Level 1Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2085 2085 0000 2139086 100000 130 8000- 12000 10000(M)

2527 2527 0000 3443416 100000 130 13324- 19985 16098

2777 2777 0000 2014938 100000 110 9975- 14963 9420

3128 3130 -0002 7533379 100000 130 29367- 44051 35218

3329 3330 -0001 2677413 100000 120 11758- 17638 12517

3682 3685 -0003 3086462 100000 130 11464- 17196 14429

4042 4043 -0001 2584175 100000 120 11819- 17728 12081

4190 4191 -0001 1261883 100000 120 5577- 8366 5899

Average of Peak Amounts = 123

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 4153239 100000 130 8000- 12000 10000

10162012Page 186 of 323

Data File vr479200d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 7841143 100000 130 14654- 21981 18880

6964 6964 0000 6845178 100000 120 14108- 21162 16482

7165 7165 0000 3797116 100000 120 7567- 11351 9143

7602 7602 0000 3408191 100000 120 7053- 10579 8206

8893 8893 0000 3898216 100000 110 9199- 13799 9386

9115 9115 0000 2329661 100000 110 5953- 8930 5609

10153 10153 0000 1882356 100000 110 4647- 6971 4532

Average of Peak Amounts = 121

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10625 10624 0001 13614701 250000 29 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 187 of 323

Data File vr479200d

Date 30-SEP-2012 1704

Client ID Instrument PESTGC9i

Sample Info ic-SG1660L1_00013 Operator

10162012Page 188 of 323

Data File vr479201d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479201dLab Smp Id IC-SG1660L2_00013 Inj Date 30-SEP-2012 1720 Operator Inst ID PESTGC9iSmp Info SG1660L2_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 8 Calibration Sample Level 2Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2084 2085 -0001 7913738 500000 500 8000- 12000 10000(M)

2526 2527 -0001 14188692 500000 520 13324- 19985 17929

2776 2777 -0001 9251204 500000 520 9975- 14963 11690

3128 3130 -0002 30672168 500000 520 29367- 44051 38758

3329 3330 -0001 11866731 500000 520 11758- 17638 14995

3682 3685 -0003 12239557 500000 520 11464- 17196 15466

4043 4043 0000 11505820 500000 510 11819- 17728 14539

4190 4191 -0001 4734436 500000 470 5577- 8366 5983

Average of Peak Amounts = 508

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 16554914 500000 510 8000- 12000 10000

10162012Page 189 of 323

Data File vr479201d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6523 6522 0001 30454619 500000 500 14654- 21981 18396

6965 6964 0001 27541094 500000 500 14108- 21162 16636

7165 7165 0000 15230911 500000 500 7567- 11351 9200

7603 7602 0001 13295973 500000 490 7053- 10579 8031

8894 8893 0001 17336408 500000 500 9199- 13799 10472

9115 9115 0000 10923449 500000 520 5953- 8930 6598

10154 10153 0001 8691093 500000 500 4647- 6971 5250

Average of Peak Amounts = 503

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10625 10624 0001 24972013 500000 53 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 190 of 323

Data File vr479201d

Date 30-SEP-2012 1720

Client ID Instrument PESTGC9i

Sample Info SG1660L2_00013 Operator

10162012Page 191 of 323

Data File vr479202d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479202dLab Smp Id IC-SG1660L3_00019 Inj Date 30-SEP-2012 1735 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 9 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2085 2085 0000 14690255 100000 920 8000- 12000 10000(M)

2527 2527 0000 25503333 100000 940 13324- 19985 17361

2777 2777 0000 16986172 100000 950 9975- 14963 11563

3130 3130 0000 55786970 100000 940 29367- 44051 37975

3330 3330 0000 21962918 100000 960 11758- 17638 14951

3685 3685 0000 22517485 100000 950 11464- 17196 15328

4043 4043 0000 21540272 100000 960 11819- 17728 14663

4191 4191 0000 8630325 100000 850 5577- 8366 5875

Average of Peak Amounts = 933

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6072 6072 0000 31025367 100000 950 8000- 12000 10000

10162012Page 192 of 323

Data File vr479202d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 57128111 100000 940 14654- 21981 18413

6964 6964 0000 53235986 100000 960 14108- 21162 17159

7165 7165 0000 28586487 100000 950 7567- 11351 9214

7602 7602 0000 25567248 100000 940 7053- 10579 8241

8893 8893 0000 33172625 100000 960 9199- 13799 10692

9115 9115 0000 20031237 100000 950 5953- 8930 6456

10153 10153 0000 16914378 100000 980 4647- 6971 5452

Average of Peak Amounts = 955

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 45507407 100000 97 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 193 of 323

Data File vr479202d

Date 30-SEP-2012 1735

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 194 of 323

Data File vr479203d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479203dLab Smp Id IC-SG1660L4_00013 Inj Date 30-SEP-2012 1751 Operator Inst ID PESTGC9iSmp Info SG1660L4_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 10 Calibration Sample Level 4Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2083 2085 -0002 21317999 150000 1300 8000- 12000 10000(M)

2527 2527 0000 37720095 150000 1400 13324- 19985 17694

2775 2777 -0002 25705034 150000 1400 9975- 14963 12058

3128 3130 -0002 82482485 150000 1400 29367- 44051 38691

3328 3330 -0002 32955239 150000 1400 11758- 17638 15459

3683 3685 -0002 31648230 150000 1300 11464- 17196 14846

4042 4043 -0001 32309208 150000 1400 11819- 17728 15156

4188 4191 -0003 15857466 150000 1600 5577- 8366 7439

Average of Peak Amounts = 141e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6071 6072 -0001 45229464 150000 1400 8000- 12000 10000

10162012Page 195 of 323

Data File vr479203d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6522 6522 0000 83094008 150000 1400 14654- 21981 18372

6963 6964 -0001 77818190 150000 1400 14108- 21162 17205

7164 7165 -0001 41589423 150000 1400 7567- 11351 9195

7602 7602 0000 37163734 150000 1400 7053- 10579 8217

8893 8893 0000 49966572 150000 1400 9199- 13799 11047

9115 9115 0000 30184937 150000 1400 5953- 8930 6674

10153 10153 0000 25637846 150000 1500 4647- 6971 5668

Average of Peak Amounts = 141e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 65805444 150000 140 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 196 of 323

Data File vr479203d

Date 30-SEP-2012 1751

Client ID Instrument PESTGC9i

Sample Info SG1660L4_00013 Operator

10162012Page 197 of 323

Data File vr479204d Page 1 Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479204dLab Smp Id IC-SG1660L5_00013 Inj Date 30-SEP-2012 1807 Operator Inst ID PESTGC9iSmp Info SG1660L5_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 11 Calibration Sample Level 5Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2084 2085 -0001 34065069 250000 2100 8000- 12000 10000(M)

2526 2527 -0001 56733462 250000 2100 13324- 19985 16654

2775 2777 -0002 42475382 250000 2400 9975- 14963 12469

3127 3130 -0003 125050351 250000 2100 29367- 44051 36709

3328 3330 -0002 50069130 250000 2200 11758- 17638 14698

3681 3685 -0004 48815297 250000 2000 11464- 17196 14330

4043 4043 0000 50326849 250000 2200 11819- 17728 14774

4190 4191 -0001 23748661 250000 2300 5577- 8366 6972

Average of Peak Amounts = 219e+03

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6071 6072 -0001 68912349 250000 2100 8000- 12000 10000

10162012Page 198 of 323

Data File vr479204d Page 2 Report Date 01-Oct-2012 0846

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6521 6522 -0001 126227611 250000 2100 14654- 21981 18317

6964 6964 0000 121529078 250000 2200 14108- 21162 17635

7164 7165 -0001 65183263 250000 2200 7567- 11351 9459

7601 7602 -0001 60754093 250000 2200 7053- 10579 8816

8892 8893 -0001 79243490 250000 2300 9199- 13799 11499

9114 9115 -0001 51279969 250000 2400 5953- 8930 7441

10153 10153 0000 40032694 250000 2300 4647- 6971 5809

Average of Peak Amounts = 223e+03

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10624 10624 0000 83140007 200000 180 8000- 12000 10000

-------------------------------------------------------------------------------

QC Flag Legend

M - Compound response manually integrated

10162012Page 199 of 323

Data File vr479204d

Date 30-SEP-2012 1807

Client ID Instrument PESTGC9i

Sample Info SG1660L5_00013 Operator

10162012Page 200 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vf479205d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1221 Peak 1 16651595 - 17351665PCB-1221 Peak 2 21352065 - 22052135PCB-1221 Peak 3 26722602 - 27422672PCB-1221 Peak 4 28732803 - 29432873PCB-1221 Peak 5 29612891 - 30312961PCB-1221 Peak 6 37393669 - 38093739PCB-1221 Peak 7 40834013 - 41534083PCB-1221 Peak 8 44774407 - 45474477

FORM VI 8082 10162012Page 201 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992612 vf479205d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

47106PCB-1221 Peak 1 Ave 20047106130012961PCB-1221 Peak 2 Ave 20012960750058524PCB-1221 Peak 3 Ave 20058523710040015PCB-1221 Peak 4 Ave 20040015420013789PCB-1221 Peak 5 Ave 20013788908018488PCB-1221 Peak 6 Ave 20018488040061501PCB-1221 Peak 7 Ave 20061500800024165PCB-1221 Peak 8 Ave 200241652800

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 202 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17848Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vf479205d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1221 Peak 1 Ave 4710613 1000PCB-1221 Peak 2 Ave 1296075 1000PCB-1221 Peak 3 Ave 5852371 1000PCB-1221 Peak 4 Ave 4001542 1000PCB-1221 Peak 5 Ave 13788908 1000PCB-1221 Peak 6 Ave 1848804 1000PCB-1221 Peak 7 Ave 615008 1000PCB-1221 Peak 8 Ave 2416528 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 203 of 323

Data File vf479205d Report Date 01-Oct-2012 0846

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479205dLab Smp Id IC-SG1221L3_00014 Inj Date 30-SEP-2012 1822 Operator Inst ID PESTGC9iSmp Info ic SG1221L3_00014Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0846 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 12 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12210subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

22 Aroclor-1221 CAS 11104-28-2

1665 1665 0000 4710613 100000 1000 8000- 12000 10000

2135 2135 0000 1296075 100000 1000 2201- 3302 2751

2672 2672 0000 5852371 100000 1000 9939- 14909 12424

2873 2873 0000 4001542 100000 1000 6796- 10194 8495

2961 2961 0000 13788908 100000 1000 23418- 35126 29272

3739 3739 0000 1848804 100000 1000 3140- 4710 3925

4083 4083 0000 615008 100000 1000 1044- 1567 1306

4477 4477 0000 2416528 100000 1000 4104- 6156 5130

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 204 of 323

Data File vf479205d

Date 30-SEP-2012 1822

Client ID Instrument PESTGC9i

Sample Info ic SG1221L3_00014 Operator

10162012Page 205 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vr479205d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1221 Peak 1 11111041 - 11811111PCB-1221 Peak 2 15111441 - 15811511PCB-1221 Peak 3 18601790 - 19301860PCB-1221 Peak 4 20822012 - 21522082PCB-1221 Peak 5 25282458 - 25982528PCB-1221 Peak 6 26022532 - 26722602PCB-1221 Peak 7 26852615 - 27552685PCB-1221 Peak 8 31303060 - 32003130

FORM VI 8082 10162012Page 206 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992612 vr479205d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

64024PCB-1221 Peak 1 Ave 20064024020030571PCB-1221 Peak 2 Ave 20030571000095270PCB-1221 Peak 3 Ave 20095269770024981PCB-1221 Peak 4 Ave 20024981158027336PCB-1221 Peak 5 Ave 20027336400022123PCB-1221 Peak 6 Ave 20022122590041633PCB-1221 Peak 7 Ave 20041632790048909PCB-1221 Peak 8 Ave 200489094700

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 207 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17841Calibration Start Date Calibration End Date09302012 1822

N

09302012 1822

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992612 vr479205d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1221 Peak 1 Ave 6402402 1000PCB-1221 Peak 2 Ave 3057100 1000PCB-1221 Peak 3 Ave 9526977 1000PCB-1221 Peak 4 Ave 24981158 1000PCB-1221 Peak 5 Ave 2733640 1000PCB-1221 Peak 6 Ave 2212259 1000PCB-1221 Peak 7 Ave 4163279 1000PCB-1221 Peak 8 Ave 4890947 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 208 of 323

Data File vr479205d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479205dLab Smp Id IC-SG1221L3_00014 Inj Date 30-SEP-2012 1822 Operator Inst ID PESTGC9iSmp Info ic SG1221L3_00014Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 12 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12210subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

22 Aroclor-1221 CAS 11104-28-2

1111 1111 0000 6402402 100000 1000 8000- 12000 10000(M)

1511 1511 0000 3057100 100000 1000 3820- 5730 4775

1860 1860 0000 9526977 100000 1000 11904- 17856 14880

2082 2082 0000 24981158 100000 1000 31215- 46822 39018

2528 2528 0000 2733640 100000 1000 3416- 5124 4270

2602 2602 0000 2212259 100000 1000 2764- 4146 3455

2685 2685 0000 4163279 100000 1000 5202- 7803 6503

3130 3130 0000 4890947 100000 1000 6111- 9167 7639

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 209 of 323

Data File vr479205d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 210 of 323

Data File vr479205d

Date 30-SEP-2012 1822

Client ID Instrument PESTGC9i

Sample Info ic SG1221L3_00014 Operator

10162012Page 211 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vf479206d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1232 Peak 1 29612891 - 30312961PCB-1232 Peak 2 36403570 - 37103640PCB-1232 Peak 3 40854015 - 41554085PCB-1232 Peak 4 47224652 - 47924722PCB-1232 Peak 5 49024832 - 49724902PCB-1232 Peak 6 50875017 - 51575087PCB-1232 Peak 7 55425472 - 56125542PCB-1232 Peak 8 57515681 - 58215751

FORM VI 8082 10162012Page 212 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992613 vf479206d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

97711PCB-1232 Peak 1 Ave 20097710620094688PCB-1232 Peak 2 Ave 20094688030035761PCB-1232 Peak 3 Ave 20035761260066995PCB-1232 Peak 4 Ave 20066994820050607PCB-1232 Peak 5 Ave 20050607280041053PCB-1232 Peak 6 Ave 20041053380057396PCB-1232 Peak 7 Ave 20057395890062677PCB-1232 Peak 8 Ave 200626765000

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 213 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17849Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vf479206d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1232 Peak 1 Ave 9771062 1000PCB-1232 Peak 2 Ave 9468803 1000PCB-1232 Peak 3 Ave 3576126 1000PCB-1232 Peak 4 Ave 6699482 1000PCB-1232 Peak 5 Ave 5060728 1000PCB-1232 Peak 6 Ave 4105338 1000PCB-1232 Peak 7 Ave 5739589 1000PCB-1232 Peak 8 Ave 6267650 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 214 of 323

Data File vf479206d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479206dLab Smp Id ic SG1232L3_00013 Inj Date 30-SEP-2012 1838 Operator Inst ID PESTGC9iSmp Info ic SG1232L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 13 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12320subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

23 Aroclor-1232 CAS 11141-16-5

2961 2961 0000 9771062 100000 1000 8000- 12000 10000

3640 3640 0000 9468803 100000 1000 7753- 11629 9691

4085 4085 0000 3576126 100000 1000 2928- 4392 3660

4722 4722 0000 6699482 100000 1000 5485- 8228 6856

4902 4902 0000 5060728 100000 1000 4143- 6215 5179

5087 5087 0000 4105338 100000 1000 3361- 5042 4202

5542 5542 0000 5739589 100000 1000 4699- 7049 5874

5751 5751 0000 6267650 100000 1000 5132- 7697 6415

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 215 of 323

Data File vf479206d

Date 30-SEP-2012 1838

Client ID Instrument PESTGC9i

Sample Info ic SG1232L3_00013 Operator

10162012Page 216 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vr479206d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1232 Peak 1 20822012 - 21522082PCB-1232 Peak 2 25262456 - 25962526PCB-1232 Peak 3 27762706 - 28462776PCB-1232 Peak 4 31283058 - 31983128PCB-1232 Peak 5 33293259 - 33993329PCB-1232 Peak 6 34243354 - 34943424PCB-1232 Peak 7 40423972 - 41124042PCB-1232 Peak 8 46144544 - 46844614

FORM VI 8082 10162012Page 217 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992613 vr479206d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

18402PCB-1232 Peak 1 Ave 20018402354014182PCB-1232 Peak 2 Ave 20014181613010089PCB-1232 Peak 3 Ave 20010089309027669PCB-1232 Peak 4 Ave 20027669356010841PCB-1232 Peak 5 Ave 20010840936085833PCB-1232 Peak 6 Ave 20085833230011581PCB-1232 Peak 7 Ave 20011580551048393PCB-1232 Peak 8 Ave 200483934800

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 218 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17842Calibration Start Date Calibration End Date09302012 1838

N

09302012 1838

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992613 vr479206d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1232 Peak 1 Ave 18402354 1000PCB-1232 Peak 2 Ave 14181613 1000PCB-1232 Peak 3 Ave 10089309 1000PCB-1232 Peak 4 Ave 27669356 1000PCB-1232 Peak 5 Ave 10840936 1000PCB-1232 Peak 6 Ave 8583323 1000PCB-1232 Peak 7 Ave 11580551 1000PCB-1232 Peak 8 Ave 4839348 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 219 of 323

Data File vr479206d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479206dLab Smp Id ic SG1232L3_00013 Inj Date 30-SEP-2012 1838 Operator Inst ID PESTGC9iSmp Info ic SG1232L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 13 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12320subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

23 Aroclor-1232 CAS 11141-16-5

2082 2082 0000 18402354 100000 1000 8000- 12000 10000

2526 2526 0000 14181613 100000 1000 6165- 9248 7706

2776 2776 0000 10089309 100000 1000 4386- 6579 5483

3128 3128 0000 27669356 100000 1000 12029- 18043 15036

3329 3329 0000 10840936 100000 1000 4713- 7069 5891

3424 3424 0000 8583323 100000 1000 3731- 5597 4664

4042 4042 0000 11580551 100000 1000 5034- 7552 6293

4614 4614 0000 4839348 100000 1000 2104- 3156 2630

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 220 of 323

Data File vr479206d

Date 30-SEP-2012 1838

Client ID Instrument PESTGC9i

Sample Info ic SG1232L3_00013 Operator

10162012Page 221 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vf479207d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1242 Peak 1 29612891 - 30312961PCB-1242 Peak 2 36413571 - 37113641PCB-1242 Peak 3 40864016 - 41564086PCB-1242 Peak 4 44794409 - 45494479PCB-1242 Peak 5 47234653 - 47934723PCB-1242 Peak 6 51585088 - 52285158PCB-1242 Peak 7 57525682 - 58225752PCB-1242 Peak 8 62656195 - 63356265

FORM VI 8082 10162012Page 222 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992614 vf479207d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

81414PCB-1242 Peak 1 Ave 20081414290015365PCB-1242 Peak 2 Ave 20015365311065982PCB-1242 Peak 3 Ave 20065981950028106PCB-1242 Peak 4 Ave 20028106459012209PCB-1242 Peak 5 Ave 20012208628069961PCB-1242 Peak 6 Ave 20069960990010615PCB-1242 Peak 7 Ave 20010615499010283PCB-1242 Peak 8 Ave 200102828980

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 223 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17850Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vf479207d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1242 Peak 1 Ave 8141429 1000PCB-1242 Peak 2 Ave 15365311 1000PCB-1242 Peak 3 Ave 6598195 1000PCB-1242 Peak 4 Ave 28106459 1000PCB-1242 Peak 5 Ave 12208628 1000PCB-1242 Peak 6 Ave 6996099 1000PCB-1242 Peak 7 Ave 10615499 1000PCB-1242 Peak 8 Ave 10282898 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 224 of 323

Data File vf479207d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479207dLab Smp Id ic SG1242L3_00013 Inj Date 30-SEP-2012 1854 Operator Inst ID PESTGC9iSmp Info ic SG1242L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 14 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12420subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

24 Aroclor-1242 CAS 53469-21-9

2961 2961 0000 8141429 100000 1000 8000- 12000 10000(M)

3641 3641 0000 15365311 100000 1000 15098- 22648 18873

4086 4086 0000 6598195 100000 1000 6484- 9725 8104

4479 4479 0000 28106459 100000 1000 27618- 41427 34523

4723 4723 0000 12208628 100000 1000 11997- 17995 14996

5158 5158 0000 6996099 100000 1000 6875- 10312 8593

5752 5752 0000 10615499 100000 1000 10431- 15647 13039

6265 6265 0000 10282898 100000 1000 10104- 15156 12630

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 225 of 323

Data File vf479207d Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 226 of 323

Data File vf479207d

Date 30-SEP-2012 1854

Client ID Instrument PESTGC9i

Sample Info ic SG1242L3_00013 Operator

10162012Page 227 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vr479207d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1242 Peak 1 20832013 - 21532083PCB-1242 Peak 2 25272457 - 25972527PCB-1242 Peak 3 27772707 - 28472777PCB-1242 Peak 4 31293059 - 31993129PCB-1242 Peak 5 33293259 - 33993329PCB-1242 Peak 6 36853615 - 37553685PCB-1242 Peak 7 40443974 - 41144044PCB-1242 Peak 8 51265056 - 51965126

FORM VI 8082 10162012Page 228 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992614 vr479207d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

13527PCB-1242 Peak 1 Ave 20013526845020219PCB-1242 Peak 2 Ave 20020218998014340PCB-1242 Peak 3 Ave 20014339987044262PCB-1242 Peak 4 Ave 20044261735017388PCB-1242 Peak 5 Ave 20017387684018314PCB-1242 Peak 6 Ave 20018314121017750PCB-1242 Peak 7 Ave 20017749733015393PCB-1242 Peak 8 Ave 200153932670

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 229 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17843Calibration Start Date Calibration End Date09302012 1854

N

09302012 1854

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992614 vr479207d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1242 Peak 1 Ave 13526845 1000PCB-1242 Peak 2 Ave 20218998 1000PCB-1242 Peak 3 Ave 14339987 1000PCB-1242 Peak 4 Ave 44261735 1000PCB-1242 Peak 5 Ave 17387684 1000PCB-1242 Peak 6 Ave 18314121 1000PCB-1242 Peak 7 Ave 17749733 1000PCB-1242 Peak 8 Ave 15393267 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 230 of 323

Data File vr479207d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479207dLab Smp Id ic SG1242L3_00013 Inj Date 30-SEP-2012 1854 Operator Inst ID PESTGC9iSmp Info ic SG1242L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 14 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12420subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

24 Aroclor-1242 CAS 53469-21-9

2083 2083 0000 13526845 100000 1000 8000- 12000 10000(M)

2527 2527 0000 20218998 100000 1000 11958- 17937 14947

2777 2777 0000 14339987 100000 1000 8481- 12721 10601

3129 3129 0000 44261735 100000 1000 26177- 39266 32721

3329 3329 0000 17387684 100000 1000 10283- 15425 12854

3685 3685 0000 18314121 100000 1000 10831- 16247 13539

4044 4044 0000 17749733 100000 1000 10497- 15746 13122

5126 5126 0000 15393267 100000 1000 9104- 13656 11380

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 231 of 323

Data File vr479207d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 232 of 323

Data File vr479207d

Date 30-SEP-2012 1854

Client ID Instrument PESTGC9i

Sample Info ic SG1242L3_00013 Operator

10162012Page 233 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vf479208d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1248 Peak 1 36373567 - 37073637PCB-1248 Peak 2 44734403 - 45434473PCB-1248 Peak 3 49514881 - 50214951PCB-1248 Peak 4 50865016 - 51565086PCB-1248 Peak 5 55415471 - 56115541PCB-1248 Peak 6 57505680 - 58205750PCB-1248 Peak 7 61916121 - 62616191PCB-1248 Peak 8 62626192 - 63326262

FORM VI 8082 10162012Page 234 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992615 vf479208d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

89356PCB-1248 Peak 1 Ave 20089355610020760PCB-1248 Peak 2 Ave 20020759623031559PCB-1248 Peak 3 Ave 20031559070012341PCB-1248 Peak 4 Ave 20012341389015809PCB-1248 Peak 5 Ave 20015808884017466PCB-1248 Peak 6 Ave 20017465791016624PCB-1248 Peak 7 Ave 20016623508019431PCB-1248 Peak 8 Ave 200194311040

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 235 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17851Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vf479208d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1248 Peak 1 Ave 8935561 1000PCB-1248 Peak 2 Ave 20759623 1000PCB-1248 Peak 3 Ave 3155907 1000PCB-1248 Peak 4 Ave 12341389 1000PCB-1248 Peak 5 Ave 15808884 1000PCB-1248 Peak 6 Ave 17465791 1000PCB-1248 Peak 7 Ave 16623508 1000PCB-1248 Peak 8 Ave 19431104 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 236 of 323

Data File vf479208d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479208dLab Smp Id ic SG1248L3_00013 Inj Date 30-SEP-2012 1909 Operator Inst ID PESTGC9iSmp Info ic SG1248L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 15 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12480subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

25 Aroclor-1248 CAS 12672-29-6

3637 3637 0000 8935561 100000 1000 8000- 12000 10000

4473 4473 0000 20759623 100000 1000 18586- 27879 23233

4951 4951 0000 3155907 100000 1000 2825- 4238 3532

5086 5086 0000 12341389 100000 1000 11049- 16574 13812

5541 5541 0000 15808884 100000 1000 14154- 21231 17692

5750 5750 0000 17465791 100000 1000 15637- 23456 19546

6191 6191 0000 16623508 100000 1000 14883- 22325 18604

6262 6262 0000 19431104 100000 1000 17397- 26095 21746

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 237 of 323

Data File vf479208d

Date 30-SEP-2012 1909

Client ID Instrument PESTGC9i

Sample Info ic SG1248L3_00013 Operator

10162012Page 238 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vr479208d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1248 Peak 1 25252455 - 25952525PCB-1248 Peak 2 31243054 - 31943124PCB-1248 Peak 3 34233353 - 34933423PCB-1248 Peak 4 36783608 - 37483678PCB-1248 Peak 5 40413971 - 41114041PCB-1248 Peak 6 41864116 - 42564186PCB-1248 Peak 7 46154545 - 46854615PCB-1248 Peak 8 51245054 - 51945124

FORM VI 8082 10162012Page 239 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992615 vr479208d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

11417PCB-1248 Peak 1 Ave 20011416682034274PCB-1248 Peak 2 Ave 20034273988063635PCB-1248 Peak 3 Ave 20063635020034030PCB-1248 Peak 4 Ave 20034030097030220PCB-1248 Peak 5 Ave 20030220358018203PCB-1248 Peak 6 Ave 20018202681015611PCB-1248 Peak 7 Ave 20015610993034370PCB-1248 Peak 8 Ave 200343696460

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 240 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17844Calibration Start Date Calibration End Date09302012 1909

N

09302012 1909

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992615 vr479208d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1248 Peak 1 Ave 11416682 1000PCB-1248 Peak 2 Ave 34273988 1000PCB-1248 Peak 3 Ave 6363502 1000PCB-1248 Peak 4 Ave 34030097 1000PCB-1248 Peak 5 Ave 30220358 1000PCB-1248 Peak 6 Ave 18202681 1000PCB-1248 Peak 7 Ave 15610993 1000PCB-1248 Peak 8 Ave 34369646 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 241 of 323

Data File vr479208d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479208dLab Smp Id ic SG1248L3_00013 Inj Date 30-SEP-2012 1909 Operator Inst ID PESTGC9iSmp Info ic SG1248L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 15 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12480subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

25 Aroclor-1248 CAS 12672-29-6

2525 2525 0000 11416682 100000 1000 8000- 12000 10000(M)

3124 3124 0000 34273988 100000 1000 24017- 36025 30021

3423 3423 0000 6363502 100000 1000 4459- 6689 5574

3678 3678 0000 34030097 100000 1000 23846- 35769 29807

4041 4041 0000 30220358 100000 1000 21176- 31764 26470

4186 4186 0000 18202681 100000 1000 12755- 19133 15944

4615 4615 0000 15610993 100000 1000 10939- 16409 13674

5124 5124 0000 34369646 100000 1000 24084- 36126 30105

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 242 of 323

Data File vr479208d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 243 of 323

Data File vr479208d

Date 30-SEP-2012 1909

Client ID Instrument PESTGC9i

Sample Info ic SG1248L3_00013 Operator

10162012Page 244 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)GC Column CLP-2 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vf479209d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1254 Peak 1 50855015 - 51555085PCB-1254 Peak 2 62536183 - 63236253PCB-1254 Peak 3 65806510 - 66506580PCB-1254 Peak 4 71577087 - 72277157PCB-1254 Peak 5 73717301 - 74417371PCB-1254 Peak 6 85968526 - 86668596PCB-1254 Peak 7 90869016 - 91569086PCB-1254 Peak 8 98439773 - 99139843

FORM VI 8082 10162012Page 245 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)CLP-2 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992616 vf479209d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

97124PCB-1254 Peak 1 Ave 20097124230016374PCB-1254 Peak 2 Ave 20016373834017590PCB-1254 Peak 3 Ave 20017589776013684PCB-1254 Peak 4 Ave 20013683949027505PCB-1254 Peak 5 Ave 20027504947017262PCB-1254 Peak 6 Ave 20017261880028714PCB-1254 Peak 7 Ave 20028713900074774PCB-1254 Peak 8 Ave 200747739500

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 246 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17852Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

GC Column CLP-2 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vf479209d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1254 Peak 1 Ave 9712423 1000PCB-1254 Peak 2 Ave 16373834 1000PCB-1254 Peak 3 Ave 17589776 1000PCB-1254 Peak 4 Ave 13683949 1000PCB-1254 Peak 5 Ave 27504947 1000PCB-1254 Peak 6 Ave 17261880 1000PCB-1254 Peak 7 Ave 28713900 1000PCB-1254 Peak 8 Ave 7477395 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 247 of 323

Data File vf479209d Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontSep1209-30-12ical30sep12abvf479209dLab Smp Id ic SG1254L3_00013 Inj Date 30-SEP-2012 1925 Operator Inst ID PESTGC9iSmp Info ic SG1254L3_00013Misc Info Comment Method chem1PESTGC9i8082frontSep1209-30-12ical30sep12ab08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 16 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12540subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

26 Aroclor-1254 CAS 11097-69-1

5085 5085 0000 9712423 100000 1000 8000- 12000 10000

6253 6253 0000 16373834 100000 1000 13487- 20230 16859

6580 6580 0000 17589776 100000 1000 14488- 21733 18111

7157 7157 0000 13683949 100000 1000 11271- 16907 14089

7371 7371 0000 27504947 100000 1000 22655- 33983 28319

8596 8596 0000 17261880 100000 1000 14218- 21328 17773

9086 9086 0000 28713900 100000 1000 23651- 35477 29564

9843 9843 0000 7477395 100000 1000 6159- 9239 7699

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 248 of 323

Data File vf479209d

Date 30-SEP-2012 1925

Client ID Instrument PESTGC9i

Sample Info ic SG1254L3_00013 Operator

10162012Page 249 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)GC Column CLP-1 ID

EXTERNAL STANDARD RETENTION TIME SUMMARY

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vr479209d

ANALYTE LVL 1 AVG RTRT WINDOW

PCB-1254 Peak 1 46874617 - 47574687PCB-1254 Peak 2 47624692 - 48324762PCB-1254 Peak 3 51285058 - 51985128PCB-1254 Peak 4 55695499 - 56395569PCB-1254 Peak 5 57705700 - 58405770PCB-1254 Peak 6 62216151 - 62916221PCB-1254 Peak 7 65216451 - 65916521PCB-1254 Peak 8 69656895 - 70356965

FORM VI 8082 10162012Page 250 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID GC Column Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

053(mm)CLP-1 ID

EXTERNAL STANDARD CURVE EVALUATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE ID1Level IC 460-12992616 vr479209d

MIN R^2OR COD

R^2OR COD

MAXRSD

RSDCOEFFICIENT

M2M1B

CURVETYPE

LVL 1

CFANALYTE MIN CF

24886PCB-1254 Peak 1 Ave 20024885981024126PCB-1254 Peak 2 Ave 20024125717033197PCB-1254 Peak 3 Ave 20033196979024470PCB-1254 Peak 4 Ave 20024470162043009PCB-1254 Peak 5 Ave 20043008616038112PCB-1254 Peak 6 Ave 20038111884031186PCB-1254 Peak 7 Ave 20031186488041987PCB-1254 Peak 8 Ave 200419870070

FORM VI 8082

Note The m1 coefficient is the same as Ave CF for an Ave curve type

10162012Page 251 of 323

FORM VI

Lab Name Job No

Calibration ID

SDG No

Instrument ID Heated Purge (YN)

GC SEMI VOA INITIAL CALIBRATION DATA

TestAmerica Edison 460-45537-1

PESTGC9

Analy Batch No 129926

17845Calibration Start Date Calibration End Date09302012 1925

N

09302012 1925

GC Column CLP-1 ID 053(mm)

EXTERNAL STANDARD RESPONSE AND CONCENTRATION

Calibration Files

LEVEL LAB SAMPLE ID LAB FILE IDLevel 1 IC 460-12992616 vr479209d

CURVETYPE

RESPONSEANALYTE CONCENTRATION (UGL)

LVL 1 LVL 1

PCB-1254 Peak 1 Ave 24885981 1000PCB-1254 Peak 2 Ave 24125717 1000PCB-1254 Peak 3 Ave 33196979 1000PCB-1254 Peak 4 Ave 24470162 1000PCB-1254 Peak 5 Ave 43008616 1000PCB-1254 Peak 6 Ave 38111884 1000PCB-1254 Peak 7 Ave 31186488 1000PCB-1254 Peak 8 Ave 41987007 1000

Curve Type LegendAve = Average

FORM VI 8082 10162012Page 252 of 323

Data File vr479209d Page 1 Report Date 01-Oct-2012 0847

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearSep1209-30-12ical30sep12abvr479209dLab Smp Id ic SG1254L3_00013 Inj Date 30-SEP-2012 1925 Operator Inst ID PESTGC9iSmp Info ic SG1254L3_00013Misc Info Comment Method chem1PESTGC9i8082rearSep1209-30-12ical30sep12ab08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 16 Calibration Sample Level 3Dil Factor 100000 Integrator Falcon Compound Sublist AR12540subTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

AMOUNTS

CAL-AMT ON-COL

RT EXP RT DLT RT RESPONSE ( ugL) ( ugL) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

26 Aroclor-1254 CAS 11097-69-1

4687 4687 0000 24885981 100000 1000 8000- 12000 10000(M)

4762 4762 0000 24125717 100000 1000 7756- 11633 9695

5128 5128 0000 33196979 100000 1000 10672- 16008 13340

5569 5569 0000 24470162 100000 1000 7866- 11799 9833

5770 5770 0000 43008616 100000 1000 13826- 20739 17282

6221 6221 0000 38111884 100000 1000 12252- 18378 15315

6521 6521 0000 31186488 100000 1000 10025- 15038 12532

6965 6965 0000 41987007 100000 1000 13497- 20246 16872

Average of Peak Amounts = 1e+03

-------------------------------------------------------------------------------

10162012Page 253 of 323

Data File vr479209d Page 2 Report Date 01-Oct-2012 0847

QC Flag Legend

M - Compound response manually integrated

10162012Page 254 of 323

Data File vr479209d

Date 30-SEP-2012 1925

Client ID Instrument PESTGC9i

Sample Info ic SG1254L3_00013 Operator

10162012Page 255 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-2

TestAmerica Edison

Lab File ID vf479493d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1005610273 979 1000 -21 150Ave

PCB-1016 Peak 2 2214321113 1050 1000 49 150Ave

PCB-1016 Peak 3 96058714 1100 1000 102 150Ave

PCB-1016 Peak 4 4004137710 1060 1000 62 150Ave

PCB-1016 Peak 5 1906116455 1160 1000 158 150Ave

PCB-1016 Peak 6 104069770 1070 1000 65 150Ave

PCB-1016 Peak 7 1271211990 1060 1000 60 150Ave

PCB-1016 Peak 8 1381712146 1140 1000 138 150Ave

PCB-1260 Peak 1 2403322106 1090 1000 87 150Ave

PCB-1260 Peak 2 2694125092 1070 1000 74 150Ave

PCB-1260 Peak 3 4112136867 1120 1000 115 150Ave

PCB-1260 Peak 4 1829116241 1130 1000 126 150Ave

PCB-1260 Peak 5 102408814 1160 1000 162 150Ave

PCB-1260 Peak 6 1863416926 1100 1000 101 150Ave

PCB-1260 Peak 7 2108721064 1000 1000 01 150Ave

PCB-1260 Peak 8 80147857 1020 1000 20 150Ave

DCB Decachlorobiphenyl 267686265963 101 100 06 150Ave

FORM VII 8082

10162012Page 256 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-2

TestAmerica Edison

Lab File ID vf479493d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 292 289 303

PCB-1016 Peak 2 359 357 371

PCB-1016 Peak 3 404 401 415

PCB-1016 Peak 4 443 441 455

PCB-1016 Peak 5 468 465 479

PCB-1016 Peak 6 511 509 523

PCB-1016 Peak 7 550 547 561

PCB-1016 Peak 8 571 568 582

PCB-1260 Peak 1 771 769 783

PCB-1260 Peak 2 816 814 828

PCB-1260 Peak 3 902 901 915

PCB-1260 Peak 4 928 926 940

PCB-1260 Peak 5 940 938 952

PCB-1260 Peak 6 986 983 997

PCB-1260 Peak 7 1059 1055 1069

PCB-1260 Peak 8 1106 1102 1116

DCB Decachlorobiphenyl 1149 1141 1161

Form VII 8082

10162012Page 257 of 323

Data File vf479493d Report Date 09-Oct-2012 0318

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479493dLab Smp Id ccvrtsg1660l3_00019 Inj Date 08-OCT-2012 1830 Operator Inst ID PESTGC9iSmp Info ccvrt-sg1660l3_00019Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 21 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2923 2961 -0038 10055641 978875 650 8000- 12000 10000(M)

3593 3641 -0048 22143043 104879 700 16892- 25338 22021

4036 4085 -0049 9604932 110224 730 6889- 10334 9552

4432 4479 -0047 40041013 106181 710 30481- 45721 39819

4678 4722 -0044 19061275 115840 770 13320- 19980 18956

5114 5158 -0044 10405886 106506 710 7564- 11346 10348

5500 5542 -0042 12711848 106020 710 9332- 13998 12642

5709 5752 -0043 13817418 113758 760 9784- 14675 13741

Average of Peak Concentrations = 720

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7706 7756 -0050 24033075 108715 720 8000- 12000 10000(M)

10162012Page 258 of 323

Data File vf479493d Report Date 09-Oct-2012 0318

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8161 8215 -0054 26941342 107369 720 9103- 13655 11210

9020 9084 -0064 41121424 111541 740 14090- 21136 17110

9276 9332 -0056 18291174 112626 750 6105- 9158 7611

9401 9454 -0053 10239798 116171 770 3460- 5190 4261

9861 9901 -0040 18634445 110097 730 6444- 9666 7754

10594 10616 -0022 21087197 100112 670 7926- 11889 12194

11063 11086 -0023 8014273 101999 680 2968- 4452 3335

Average of Peak Concentrations = 720

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11488 11515 -0027 26768608 100648 67 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 259 of 323

Data File vf479493d

Date 08-OCT-2012 1830

Client ID Instrument PESTGC9i

Sample Info ccvrt-sg1660l3_00019 Operator

10162012Page 260 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-1

TestAmerica Edison

Lab File ID vr479493d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1317915949 826 1000 -174 150Ave

PCB-1016 Peak 2 2492127231 915 1000 -85 150Ave

PCB-1016 Peak 3 1751817953 976 1000 -24 150Ave

PCB-1016 Peak 4 5583559495 938 1000 -62 150Ave

PCB-1016 Peak 5 2224122894 971 1000 -29 150Ave

PCB-1016 Peak 6 2383923697 1010 1000 06 150Ave

PCB-1016 Peak 7 2233922413 997 1000 -03 150Ave

PCB-1016 Peak 8 1103010158 1090 1000 86 150Ave

PCB-1260 Peak 1 3241432677 992 1000 -08 150Ave

PCB-1260 Peak 2 6068660467 1000 1000 04 150Ave

PCB-1260 Peak 3 5752255452 1040 1000 37 150Ave

PCB-1260 Peak 4 2973730164 986 1000 -14 150Ave

PCB-1260 Peak 5 2720927064 1010 1000 05 150Ave

PCB-1260 Peak 6 3391634367 987 1000 -13 150Ave

PCB-1260 Peak 7 2498721162 1180 1000 181 150Ave

PCB-1260 Peak 8 1900217245 1100 1000 102 150Ave

DCB Decachlorobiphenyl 482177470701 102 100 24 150Ave

FORM VII 8082

10162012Page 261 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10082012 1830

09302012 1704

09302012 1807

CCVRT 460-1311372

CLP-1

TestAmerica Edison

Lab File ID vr479493d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 206 201 215

PCB-1016 Peak 2 250 246 260

PCB-1016 Peak 3 275 271 285

PCB-1016 Peak 4 310 306 320

PCB-1016 Peak 5 330 326 340

PCB-1016 Peak 6 365 361 375

PCB-1016 Peak 7 401 397 411

PCB-1016 Peak 8 416 412 426

PCB-1260 Peak 1 604 600 614

PCB-1260 Peak 2 650 645 659

PCB-1260 Peak 3 694 689 703

PCB-1260 Peak 4 714 709 723

PCB-1260 Peak 5 757 753 767

PCB-1260 Peak 6 886 882 896

PCB-1260 Peak 7 908 904 918

PCB-1260 Peak 8 1013 1008 1022

DCB Decachlorobiphenyl 1061 1052 1072

Form VII 8082

10162012Page 262 of 323

Data File vr479493d Page 1 Report Date 09-Oct-2012 0318

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479493dLab Smp Id ccvrtsg1660l3_00019 Inj Date 08-OCT-2012 1830 Operator Inst ID PESTGC9iSmp Info ccvrt-sg1660l3_00019Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 21 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2056 2085 -0029 13178629 826281 550 8000- 12000 10000(M)

2498 2527 -0029 24921299 915181 610 13324- 19985 18910

2746 2777 -0031 17517717 975756 650 9975- 14963 13293

3100 3130 -0030 55834574 938480 620 29367- 44051 42368

3297 3330 -0033 22240639 971476 650 11758- 17638 16876

3648 3685 -0037 23838665 100597 670 11464- 17196 18089

4011 4043 -0032 22339236 996719 660 11819- 17728 16951

4157 4191 -0034 11029779 108584 720 5577- 8366 8369

Average of Peak Concentrations = 640

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6045 6072 -0027 32414247 991956 660 8000- 12000 10000(M)

10162012Page 263 of 323

Data File vr479493d Page 2 Report Date 09-Oct-2012 0318

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6496 6522 -0026 60686283 100362 670 14654- 21981 18722

6938 6964 -0026 57521890 103733 690 14108- 21162 17746

7137 7165 -0028 29736966 985849 660 7567- 11351 9174

7572 7602 -0030 27208663 100536 670 7053- 10579 8394

8857 8893 -0036 33916486 986885 660 9199- 13799 10463

9076 9115 -0039 24987061 118075 790 5953- 8930 7709

10135 10153 -0018 19001807 110187 730 4647- 6971 5862

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 48217685 102438 68 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 264 of 323

Data File vr479493d

Date 08-OCT-2012 1830

Client ID Instrument PESTGC9i

Sample Info ccvrt-sg1660l3_00019 Operator

10162012Page 265 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-2

TestAmerica Edison

Lab File ID vf479510d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 998310273 972 1000 -28 150Ave

PCB-1016 Peak 2 2182221113 1030 1000 34 150Ave

PCB-1016 Peak 3 93438714 1070 1000 72 150Ave

PCB-1016 Peak 4 3888937710 1030 1000 31 150Ave

PCB-1016 Peak 5 1831616455 1110 1000 113 150Ave

PCB-1016 Peak 6 100909770 1030 1000 33 150Ave

PCB-1016 Peak 7 1211711990 1010 1000 11 150Ave

PCB-1016 Peak 8 1287812146 1060 1000 60 150Ave

PCB-1260 Peak 1 2305022106 1040 1000 43 150Ave

PCB-1260 Peak 2 2601125092 1040 1000 37 150Ave

PCB-1260 Peak 3 4009636867 1090 1000 88 150Ave

PCB-1260 Peak 4 1793216241 1100 1000 104 150Ave

PCB-1260 Peak 5 100168814 1140 1000 136 150Ave

PCB-1260 Peak 6 1799416926 1060 1000 63 150Ave

PCB-1260 Peak 7 2148621064 1020 1000 20 150Ave

PCB-1260 Peak 8 78557857 1000 1000 -00 150Ave

DCB Decachlorobiphenyl 262499265963 987 100 -13 150Ave

FORM VII 8082

10162012Page 266 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-2

TestAmerica Edison

Lab File ID vf479510d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 292 289 303

PCB-1016 Peak 2 359 357 371

PCB-1016 Peak 3 403 401 415

PCB-1016 Peak 4 443 441 455

PCB-1016 Peak 5 468 465 479

PCB-1016 Peak 6 511 509 523

PCB-1016 Peak 7 550 547 561

PCB-1016 Peak 8 571 568 582

PCB-1260 Peak 1 770 769 783

PCB-1260 Peak 2 816 814 828

PCB-1260 Peak 3 902 901 915

PCB-1260 Peak 4 927 926 940

PCB-1260 Peak 5 940 938 952

PCB-1260 Peak 6 986 983 997

PCB-1260 Peak 7 1059 1055 1069

PCB-1260 Peak 8 1106 1102 1116

DCB Decachlorobiphenyl 1149 1141 1161

Form VII 8082

10162012Page 267 of 323

Data File vf479510d Report Date 09-Oct-2012 0335

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479510dLab Smp Id ccv-SG1660L3_00019 Inj Date 09-OCT-2012 0147 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 40 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2922 2961 -0039 9983429 971845 650 8000- 12000 10000(M)

3591 3641 -0050 21822420 103360 690 16892- 25338 21859

4034 4085 -0051 9342806 107216 710 6889- 10334 9358

4431 4479 -0048 38888611 103125 690 30481- 45721 38953

4677 4722 -0045 18315559 111308 740 13320- 19980 18346

5112 5158 -0046 10089629 103269 690 7564- 11346 10106

5497 5542 -0045 12117410 101063 670 9332- 13998 12138

5706 5752 -0046 12878214 106025 710 9784- 14675 12900

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7703 7756 -0053 23050032 104269 700 8000- 12000 10000(M)

10162012Page 268 of 323

Data File vf479510d Report Date 09-Oct-2012 0335

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8159 8215 -0056 26011086 103662 690 9103- 13655 11285

9017 9084 -0067 40095841 108759 720 14090- 21136 17395

9273 9332 -0059 17931794 110413 740 6105- 9158 7780

9399 9454 -0055 10016237 113634 760 3460- 5190 4345

9858 9901 -0043 17994170 106314 710 6444- 9666 7807

10594 10616 -0022 21485546 102003 680 7926- 11889 12478

11061 11086 -0025 7855172 999743 670 2968- 4452 3408

Average of Peak Concentrations = 710

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11485 11515 -0030 26249946 986977 66 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 269 of 323

Data File vf479510d

Date 09-OCT-2012 0147

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 270 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION DATA

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-1

TestAmerica Edison

Lab File ID vr479510d Conc Units ugL

ANALYTE CURVE CALC SPIKE D MAX

TYPE AMOUNT AMOUNT D

AVE CF CF MIN CF

PCB-1016 Peak 1 1577315949 989 1000 -11 150Ave

PCB-1016 Peak 2 2637627231 969 1000 -31 150Ave

PCB-1016 Peak 3 1911517953 1060 1000 65 150Ave

PCB-1016 Peak 4 5729159495 963 1000 -37 150Ave

PCB-1016 Peak 5 2290722894 1000 1000 00 150Ave

PCB-1016 Peak 6 2510823697 1060 1000 60 150Ave

PCB-1016 Peak 7 2349222413 1050 1000 48 150Ave

PCB-1016 Peak 8 1095310158 1080 1000 78 150Ave

PCB-1260 Peak 1 3177332677 972 1000 -28 150Ave

PCB-1260 Peak 2 5864160467 970 1000 -30 150Ave

PCB-1260 Peak 3 5561155452 1000 1000 03 150Ave

PCB-1260 Peak 4 2920530164 968 1000 -32 150Ave

PCB-1260 Peak 5 2692527064 995 1000 -05 150Ave

PCB-1260 Peak 6 3316834367 965 1000 -35 150Ave

PCB-1260 Peak 7 2309521162 1090 1000 91 150Ave

PCB-1260 Peak 8 1649517245 957 1000 -43 150Ave

DCB Decachlorobiphenyl 444399470701 944 100 -56 150Ave

FORM VII 8082

10162012Page 271 of 323

FORM VII

Lab Name Job No

SDG No

Instrument ID

Calibration Date

Calib Start Date

Lab Sample ID

Calib End DateGC Column ID

GC SEMI VOA CONTINUING CALIBRATION RETENTION TIME SUMMARY

053(mm)

460-45537-1

PESTGC9

10092012 0147

09302012 1704

09302012 1807

CCV 460-13113719

CLP-1

TestAmerica Edison

Lab File ID vr479510d

Analyte RTTOFROM

RT WINDOW

PCB-1016 Peak 1 206 201 215

PCB-1016 Peak 2 250 246 260

PCB-1016 Peak 3 275 271 285

PCB-1016 Peak 4 310 306 320

PCB-1016 Peak 5 330 326 340

PCB-1016 Peak 6 365 361 375

PCB-1016 Peak 7 401 397 411

PCB-1016 Peak 8 416 412 426

PCB-1260 Peak 1 604 600 614

PCB-1260 Peak 2 649 645 659

PCB-1260 Peak 3 694 689 703

PCB-1260 Peak 4 714 709 723

PCB-1260 Peak 5 757 753 767

PCB-1260 Peak 6 885 882 896

PCB-1260 Peak 7 907 904 918

PCB-1260 Peak 8 1013 1008 1022

DCB Decachlorobiphenyl 1061 1052 1072

Form VII 8082

10162012Page 272 of 323

Data File vr479510d Page 1 Report Date 09-Oct-2012 0335

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479510dLab Smp Id ccv-SG1660L3_00019 Inj Date 09-OCT-2012 0147 Operator Inst ID PESTGC9iSmp Info SG1660L3_00019Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 40 Dil Factor 100000 Integrator Falcon Compound Sublist AR16600SsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2056 2085 -0029 15772630 988922 660 8000- 12000 10000(M)

2498 2527 -0029 26375750 968593 640 13324- 19985 16722

2747 2777 -0030 19114706 106471 710 9975- 14963 12119

3099 3130 -0031 57290957 962959 640 29367- 44051 36323

3296 3330 -0034 22907341 100060 670 11758- 17638 14523

3645 3685 -0040 25108132 105954 710 11464- 17196 15919

4009 4043 -0034 23491941 104815 700 11819- 17728 14894

4155 4191 -0036 10952986 107828 720 5577- 8366 6944

Average of Peak Concentrations = 680

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6043 6072 -0029 31772880 972329 650 8000- 12000 10000(M)

10162012Page 273 of 323

Data File vr479510d Page 2 Report Date 09-Oct-2012 0335

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6494 6522 -0028 58641225 969803 650 14654- 21981 18456

6936 6964 -0028 55611337 100287 670 14108- 21162 17503

7135 7165 -0030 29205460 968228 640 7567- 11351 9192

7570 7602 -0032 26925453 994891 660 7053- 10579 8474

8854 8893 -0039 33168029 965107 640 9199- 13799 10439

9072 9115 -0043 23094940 109134 730 5953- 8930 7269

10132 10153 -0021 16495029 956510 640 4647- 6971 5192

Average of Peak Concentrations = 660

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10611 10624 -0013 44439946 944122 63 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 274 of 323

Data File vr479510d

Date 09-OCT-2012 0147

Client ID Instrument PESTGC9i

Sample Info SG1660L3_00019 Operator

10162012Page 275 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1309971-A

Matrix vf479496dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2208

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

RECCAS NO LIMITSQSURROGATE

88 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 276 of 323

Data File vf479496d Report Date 09-Oct-2012 0319

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479496dLab Smp Id MB 460-1309971-a Inj Date 08-OCT-2012 2208 Operator Inst ID PESTGC9iSmp Info MB 460-1309971-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 24 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11484 11515 -0031 23517325 884233 59 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 277 of 323

Data File vf479496d

Date 08-OCT-2012 2208

Client ID Instrument PESTGC9i

Sample Info MB 460-1309971-a Operator

10162012Page 278 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID MB 460-1309971-A

Matrix vr479496dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2208

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

97 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 279 of 323

Data File vr479496d Page 1 Report Date 09-Oct-2012 0319

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479496dLab Smp Id MB 460-1309971-a Inj Date 08-OCT-2012 2208 Operator Inst ID PESTGC9iSmp Info MB 460-1309971-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 24 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 45589434 968543 64 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limits

10162012Page 280 of 323

Data File vr479496d

Date 08-OCT-2012 2208

Client ID Instrument PESTGC9i

Sample Info MB 460-1309971-a Operator

10162012Page 281 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-1311371

Matrix vf479492dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10082012 1814Sample wtvol

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

114 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 282 of 323

Data File vf479492d Page 1 Report Date 09-Oct-2012 0317

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479492dLab Smp Id piblk-sgpiblk_00013 Inj Date 08-OCT-2012 1814 Operator Inst ID PESTGC9iSmp Info sgpiblk_00013Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 20 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11496 11515 -0019 6086041 228830 15 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 283 of 323

Data File vf479492d

Date 08-OCT-2012 1814

Client ID Instrument PESTGC9i

Sample Info sgpiblk_00013 Operator

10162012Page 284 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-1311371

Matrix vr479492dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10082012 1814Sample wtvol

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

114 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 285 of 323

Data File vr479492d Report Date 09-Oct-2012 0317

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479492dLab Smp Id piblk-sgpiblk_00013 Inj Date 08-OCT-2012 1814 Operator Inst ID PESTGC9iSmp Info sgpiblk_00013Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 20 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 10738471 228138 15 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 286 of 323

Data File vr479492d

Date 08-OCT-2012 1814

Client ID Instrument PESTGC9i

Sample Info sgpiblk_00013 Operator

10162012Page 287 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-13113718

Matrix vf479509dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10092012 0131Sample wtvol

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

122 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 288 of 323

Data File vf479509d Report Date 09-Oct-2012 0313

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479509dLab Smp Id SGPIBLK_00013 Inj Date 09-OCT-2012 0131 Operator Inst ID PESTGC9iSmp Info SGPIBLK_00013Misc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 39 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11487 11515 -0028 6469383 243244 16 8000- 12000 10000(a)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

10162012Page 289 of 323

Data File vf479509d

Date 09-OCT-2012 0131

Client ID Instrument PESTGC9i

Sample Info SGPIBLK_00013 Operator

10162012Page 290 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID PIBLK 460-13113718

Matrix vr479509dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method

10092012 0131Sample wtvol

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 013U12674-11-2 PCB-1016 013

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 015U11096-82-5 PCB-1260 015

RECCAS NO LIMITSQSURROGATE

102 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 291 of 323

Data File vr479509d Report Date 09-Oct-2012 0306

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479509dLab Smp Id SGPIBLK_00013 Inj Date 09-OCT-2012 0131 Operator Inst ID PESTGC9iSmp Info SGPIBLK_00013Misc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 39 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 9634357 204681 14 8000- 12000 10000(aR)

-------------------------------------------------------------------------------

QC Flag Legend

a - Target compound detected but quantitated amountBelow Limit Of Quantitation(BLOQ)

R - SpikeSurrogate failed recovery limits

10162012Page 292 of 323

Data File vr479509d

Date 09-OCT-2012 0131

Client ID Instrument PESTGC9i

Sample Info SGPIBLK_00013 Operator

10162012Page 293 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1309972-A

Matrix vf479497dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2224

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 507

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 557

RECCAS NO LIMITSQSURROGATE

84 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 294 of 323

Data File vf479497d Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479497dLab Smp Id LCS 460-1309972-a Inj Date 08-OCT-2012 2224 Operator Inst ID PESTGC9iSmp Info LCS 460-1309972-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 25 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2926 2961 -0035 10792080 105056 700 8000- 12000 10000

3596 3641 -0045 23726579 112379 750 16892- 25338 21985

4040 4085 -0045 9881475 113398 760 6889- 10334 9156

4437 4479 -0042 42082916 111596 740 30481- 45721 38994

4683 4722 -0039 19556228 118847 790 13320- 19980 18121

5181 5158 0023 7863050 804795 540 7564- 11346 7286

5572 5542 0030 6208245 517785 340 9332- 13998 5753

5713 5752 -0039 14198514 116895 780 9784- 14675 13156

Average of Peak Concentrations = 680

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7711 7756 -0045 26515963 119947 800 8000- 12000 10000(M)

10162012Page 295 of 323

Data File vf479497d Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8168 8215 -0047 29809525 118800 790 9103- 13655 11242

9026 9084 -0058 46049501 124909 830 14090- 21136 17367

9283 9332 -0049 20194161 124344 830 6105- 9158 7616

9408 9454 -0046 11340121 128654 860 3460- 5190 4277

9864 9901 -0037 20709127 122354 820 6444- 9666 7810

10623 10616 0007 8913638 423178 280 7926- 11889 3362

11063 11086 -0023 8650385 110095 730 2968- 4452 3262

Average of Peak Concentrations = 740

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11484 11515 -0031 22216113 835308 56 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 296 of 323

Data File vf479497d

Date 08-OCT-2012 2224

Client ID Instrument PESTGC9i

Sample Info LCS 460-1309972-a Operator

10162012Page 297 of 323

Manual Integration Report

Data File vf479497dInj Date and Time 08-OCT-2012 2224Instrument ID PESTGC9iClient ID Compound 27 Aroclor-1260CAS 11096-82-5Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 776

Manual Integration Results

RT 771

Response 26515963

Amount 111428

Conc 74000

Manually Integrated By diazcManual Integration Reason

10162012Page 298 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCS 460-1309972-A

Matrix vr479497dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2224

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 483

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 573

RECCAS NO LIMITSQSURROGATE

91 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 299 of 323

Data File vr479497d Page 1 Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479497dLab Smp Id LCS 460-1309972-a Inj Date 08-OCT-2012 2224 Operator Inst ID PESTGC9iSmp Info LCS 460-1309972-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 25 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2058 2085 -0027 15080112 945502 630 8000- 12000 10000(M)

2502 2527 -0025 26928755 988901 660 13324- 19985 17857

2750 2777 -0027 19042665 106070 710 9975- 14963 12628

3103 3130 -0027 59594211 100167 670 29367- 44051 39518

3301 3330 -0029 23808984 103998 690 11758- 17638 15788

3694 3685 0009 14297782 603352 400 11464- 17196 9481

4013 4043 -0030 24245185 108176 720 11819- 17728 16078

4188 4191 -0003 10255607 100963 670 5577- 8366 6801

Average of Peak Concentrations = 640

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6048 6072 -0024 36196886 110771 740 8000- 12000 10000

10162012Page 300 of 323

Data File vr479497d Page 2 Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6500 6522 -0022 67525585 111673 740 14654- 21981 18655

6943 6964 -0021 64479188 116279 780 14108- 21162 17813

7142 7165 -0023 33072749 109644 730 7567- 11351 9137

7578 7602 -0024 30577540 112984 750 7053- 10579 8448

8864 8893 -0029 38421619 111797 740 9199- 13799 10615

9083 9115 -0032 26202367 123818 820 5953- 8930 7239

10138 10153 -0015 20706585 120073 800 4647- 6971 5721

Average of Peak Concentrations = 760

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10613 10624 -0011 42991277 913346 61 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 301 of 323

Data File vr479497d

Date 08-OCT-2012 2224

Client ID Instrument PESTGC9i

Sample Info LCS 460-1309972-a Operator

10162012Page 302 of 323

Manual Integration Report

Data File vr479497dInj Date and Time 08-OCT-2012 2224Instrument ID PESTGC9iClient ID Compound 21 Aroclor-1016CAS 12674-11-2Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 208

Manual Integration Results

RT 206

Response 15080112

Amount 96644

Conc 64000

Manually Integrated By diazcManual Integration Reason

10162012Page 303 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCSD 460-1309973-A

Matrix vf479498dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2239

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-2

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 516

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 583

RECCAS NO LIMITSQSURROGATE

99 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 304 of 323

Data File vf479498d Report Date 09-Oct-2012 0320

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082frontoct1210-08-1208oct12bbvf479498dLab Smp Id LCSd 460-1309973-a Inj Date 08-OCT-2012 2239 Operator Inst ID PESTGC9iSmp Info LCSd 460-1309973-aMisc Info Comment Method chem1PESTGC9i8082frontoct1210-08-1208oct12bb08Vf8082mMeth Date 01-Oct-2012 0847 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vf479211dAls bottle 26 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2925 2961 -0036 10994509 107027 710 8000- 12000 10000

3594 3641 -0047 24222192 114726 760 16892- 25338 22031

4039 4085 -0046 9969671 114410 760 6889- 10334 9068

4435 4479 -0044 43128755 114369 760 30481- 45721 39228

4680 4722 -0042 19946065 121217 810 13320- 19980 18142

5177 5158 0019 7960960 814816 540 7564- 11346 7241

5569 5542 0027 6392667 533166 360 9332- 13998 5814

5711 5752 -0041 14546887 119763 800 9784- 14675 13231

Average of Peak Concentrations = 690

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

7708 7756 -0048 27193660 123013 820 8000- 12000 10000(M)

10162012Page 305 of 323

Data File vf479498d Report Date 09-Oct-2012 0320

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

8164 8215 -0051 30632211 122078 810 9103- 13655 11264

9022 9084 -0062 47541251 128955 860 14090- 21136 17482

9278 9332 -0054 21062846 129693 860 6105- 9158 7745

9404 9454 -0050 11787377 133728 890 3460- 5190 4335

9862 9901 -0039 21547760 127309 850 6444- 9666 7924

10618 10616 0002 10677528 506919 340 7926- 11889 3926

11062 11086 -0024 9277293 118074 790 2968- 4452 3412

Average of Peak Concentrations = 780

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

11482 11515 -0033 26307958 989158 66 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 306 of 323

Data File vf479498d

Date 08-OCT-2012 2239

Client ID Instrument PESTGC9i

Sample Info LCSd 460-1309973-a Operator

10162012Page 307 of 323

Manual Integration Report

Data File vf479498dInj Date and Time 08-OCT-2012 2239Instrument ID PESTGC9iClient ID Compound 27 Aroclor-1260CAS 11096-82-5Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 776

Manual Integration Results

RT 771

Response 27193660

Amount 116693

Conc 78000

Manually Integrated By diazcManual Integration Reason

10162012Page 308 of 323

FORM IForm 1GC SEMI VOA ORGANICS ANALYSIS DATA SHEET

Client Sample ID

Lab Name Job No

SDG No

460-45537-1

Lab Sample ID LCSD 460-1309973-A

Matrix vr479498dLab File ID

Date Collected8082Analysis Method

Water

TestAmerica Edison

Con Extract VolVolumeInjection Volume

GPC Cleanup(YN)

Date Extracted

Date Analyzed

Dilution Factor 1

Extraction Method 3510C 10082012 0755

10082012 2239

5(mL)

Sample wtvol 1000(mL)

Moisture

GC Column ID 053(mm)CLP-1

N

Analysis Batch No 131137 ugLUnits

CAS NO COMPOUND NAME RESULT Q MDLRL

050 01312674-11-2 PCB-1016 497

050 028U11104-28-2 PCB-1221 028

050 012U11141-16-5 PCB-1232 012

050 012U53469-21-9 PCB-1242 012

050 024U12672-29-6 PCB-1248 024

050 017U11097-69-1 PCB-1254 017

050 01511096-82-5 PCB-1260 595

RECCAS NO LIMITSQSURROGATE

108 37-1502051-24-3 DCB Decachlorobiphenyl

FORM I 8082

10162012Page 309 of 323

Data File vr479498d Page 1 Report Date 09-Oct-2012 0321

TestAmerica

GC ORGANICS QUANTITATION REPORTData file chem1PESTGC9i8082rearoct1210-08-1208oct12bbvr479498dLab Smp Id LCSd 460-1309973-a Inj Date 08-OCT-2012 2239 Operator Inst ID PESTGC9iSmp Info LCSd 460-1309973-aMisc Info Comment Method chem1PESTGC9i8082rearoct1210-08-1208oct12bb08Vr8082mMeth Date 01-Oct-2012 0828 sita Quant Type ESTDCal Date 30-SEP-2012 1956 Cal File vr479211dAls bottle 26 Dil Factor 100000 Integrator Falcon Compound Sublist AllPCBsubTarget Version 350 Sample Matrix SOILProcessing Host hpd3

Concentration Formula Amt DF Vt(Ws(100-M)100) CpndVariable

Name Value Description-------------- -------------- -----------------------

DF 100000 Dilution FactorVt 1000000 Volume of final extract (mL)Ws 1500000 Weight of sample extracted (g)M 000000 Moisture

Cpnd Variable Local Compound Variable

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

21 Aroclor-1016 CAS 12674-11-2

2058 2085 -0027 15401465 965650 640 8000- 12000 10000(M)

2501 2527 -0026 27477458 100905 670 13324- 19985 17841

2750 2777 -0027 19458638 108387 720 9975- 14963 12634

3102 3130 -0028 60672366 101979 680 29367- 44051 39394

3299 3330 -0031 24206974 105737 700 11758- 17638 15717

3679 3685 -0006 17478185 737562 490 11464- 17196 11348

4012 4043 -0031 24592091 109724 730 11819- 17728 15967

4189 4191 -0002 9970290 981538 650 5577- 8366 6474

Average of Peak Concentrations = 660

-------------------------------------------------------------------------------

27 Aroclor-1260 CAS 11096-82-5

6047 6072 -0025 36957605 113099 750 8000- 12000 10000

10162012Page 310 of 323

Data File vr479498d Page 2 Report Date 09-Oct-2012 0321

CONCENTRATIONS

ON-COL FINAL

RT EXP RT DLT RT RESPONSE ( ugL) (ugkg) TARGET RANGE RATIO

== ====== ======== ======== ======= ======= ============ =====

27 Aroclor-1260 (continued)

6498 6522 -0024 69036402 114172 760 14654- 21981 18680

6940 6964 -0024 66037968 119090 790 14108- 21162 17869

7140 7165 -0025 33956993 112575 750 7567- 11351 9188

7575 7602 -0027 31643763 116923 780 7053- 10579 8562

8861 8893 -0032 40016219 116437 780 9199- 13799 10828

9080 9115 -0035 27744305 131104 870 5953- 8930 7507

10136 10153 -0017 22040150 127806 850 4647- 6971 5964

Average of Peak Concentrations = 790

-------------------------------------------------------------------------------

$ 30 Decachlorobiphenyl(surr) CAS 2051-24-3

10612 10624 -0012 50942327 108226 72 8000- 12000 10000(R)

-------------------------------------------------------------------------------

QC Flag Legend

R - SpikeSurrogate failed recovery limitsM - Compound response manually integrated

10162012Page 311 of 323

Data File vr479498d

Date 08-OCT-2012 2239

Client ID Instrument PESTGC9i

Sample Info LCSd 460-1309973-a Operator

10162012Page 312 of 323

Manual Integration Report

Data File vr479498dInj Date and Time 08-OCT-2012 2239Instrument ID PESTGC9iClient ID Compound 21 Aroclor-1016CAS 12674-11-2Report Date 10092012

Processing Integration Results

Not Detected

Expected RT 208

Manual Integration Results

RT 206

Response 15401465

Amount 99401

Conc 66000

Manually Integrated By diazcManual Integration Reason

10162012Page 313 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GC SEMI VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

PESTGC9

129926

Start Date

End Date 09302012 2043

09302012 1530

RINSE 460-1299261 CLP-2 053(mm)109302012 1530

RINSE 460-1299261 CLP-1 053(mm)109302012 1530

RINSE 460-1299262 CLP-2 053(mm)109302012 1546

RINSE 460-1299262 CLP-1 053(mm)109302012 1546

ZZZZZ CLP-2 053(mm)109302012 1602

ZZZZZ CLP-1 053(mm)109302012 1602

ZZZZZ CLP-2 053(mm)109302012 1617

ZZZZZ CLP-1 053(mm)109302012 1617

ZZZZZ CLP-2 053(mm)109302012 1633

ZZZZZ CLP-1 053(mm)109302012 1633

ZZZZZ CLP-2 053(mm)109302012 1649

ZZZZZ CLP-1 053(mm)109302012 1649

IC 460-1299267 CLP-2 053(mm)109302012 1704 vf479200d

IC 460-1299267 CLP-1 053(mm)109302012 1704 vr479200d

IC 460-1299268 CLP-2 053(mm)109302012 1720 vf479201d

IC 460-1299268 CLP-1 053(mm)109302012 1720 vr479201d

IC 460-1299269 CLP-2 053(mm)109302012 1735 vf479202d

IC 460-1299269 CLP-1 053(mm)109302012 1735 vr479202d

IC 460-12992610 CLP-2 053(mm)109302012 1751 vf479203d

IC 460-12992610 CLP-1 053(mm)109302012 1751 vr479203d

IC 460-12992611 CLP-2 053(mm)109302012 1807 vf479204d

IC 460-12992611 CLP-1 053(mm)109302012 1807 vr479204d

IC 460-12992612 CLP-2 053(mm)109302012 1822 vf479205d

IC 460-12992612 CLP-1 053(mm)109302012 1822 vr479205d

IC 460-12992613 CLP-2 053(mm)109302012 1838 vf479206d

IC 460-12992613 CLP-1 053(mm)109302012 1838 vr479206d

IC 460-12992614 CLP-2 053(mm)109302012 1854 vf479207d

IC 460-12992614 CLP-1 053(mm)109302012 1854 vr479207d

IC 460-12992615 CLP-2 053(mm)109302012 1909 vf479208d

IC 460-12992615 CLP-1 053(mm)109302012 1909 vr479208d

IC 460-12992616 CLP-2 053(mm)109302012 1925 vf479209d

IC 460-12992616 CLP-1 053(mm)109302012 1925 vr479209d

IC 460-12992617 CLP-2 053(mm)109302012 1940

IC 460-12992617 CLP-1 053(mm)109302012 1940

IC 460-12992618 CLP-2 053(mm)109302012 1956

IC 460-12992618 CLP-1 053(mm)109302012 1956

ZZZZZ CLP-2 053(mm)109302012 2011

ZZZZZ CLP-1 053(mm)109302012 2011

ZZZZZ CLP-2 053(mm)109302012 2027

ZZZZZ CLP-1 053(mm)109302012 2027

ZZZZZ CLP-2 053(mm)109302012 2043

ZZZZZ CLP-1 053(mm)109302012 2043

8082

10162012Page 314 of 323

Lab Name Job No

SDG No

Instrument ID

Analysis Batch Number

GC SEMI VOA ANALYSIS RUN LOG

DILUTION

FACTOR

COLUMN IDDATE ANALYZEDLAB SAMPLE ID CLIENT SAMPLE ID LAB FILE ID

TestAmerica Edison 460-45537-1

PESTGC9

131137

Start Date

End Date 10092012 0147

10082012 1814

PIBLK 460-1311371 CLP-2 053(mm)110082012 1814 vf479492d

PIBLK 460-1311371 CLP-1 053(mm)110082012 1814 vr479492d

CCVRT 460-1311372 CLP-2 053(mm)110082012 1830 vf479493d

CCVRT 460-1311372 CLP-1 053(mm)110082012 1830 vr479493d

ZZZZZ CLP-2 053(mm)110082012 2137

ZZZZZ CLP-1 053(mm)110082012 2137

ZZZZZ CLP-2 053(mm)110082012 2152

ZZZZZ CLP-1 053(mm)110082012 2152

MB 460-1309971-A CLP-2 053(mm)110082012 2208 vf479496d

MB 460-1309971-A CLP-1 053(mm)110082012 2208 vr479496d

LCS 460-1309972-A CLP-2 053(mm)110082012 2224 vf479497d

LCS 460-1309972-A CLP-1 053(mm)110082012 2224 vr479497d

LCSD 460-1309973-A CLP-2 053(mm)110082012 2239 vf479498d

LCSD 460-1309973-A CLP-1 053(mm)110082012 2239 vr479498d

ZZZZZ CLP-2 053(mm)110082012 2255

ZZZZZ CLP-1 053(mm)110082012 2255

ZZZZZ CLP-2 053(mm)110082012 2311

ZZZZZ CLP-1 053(mm)110082012 2311

ZZZZZ CLP-2 053(mm)110082012 2326

ZZZZZ CLP-1 053(mm)110082012 2326

ZZZZZ CLP-2 053(mm)110082012 2342

ZZZZZ CLP-1 053(mm)110082012 2342

ZZZZZ CLP-2 053(mm)110082012 2358

ZZZZZ CLP-1 053(mm)110082012 2358

ZZZZZ CLP-2 053(mm)110092012 0013

ZZZZZ CLP-1 053(mm)110092012 0013

460-45537-1 WC-17338-100512-MW14-MM-251

CLP-2 053(mm)110092012 0029 vf479505d

460-45537-1 WC-17338-100512-MW14-MM-251

CLP-1 053(mm)110092012 0029 vr479505d

460-45537-2 WC-17338-100512-MW101-MM-252

CLP-2 053(mm)110092012 0045 vf479506d

460-45537-2 WC-17338-100512-MW101-MM-252

CLP-1 053(mm)110092012 0045 vr479506d

ZZZZZ CLP-2 053(mm)110092012 0100

ZZZZZ CLP-1 053(mm)110092012 0100

ZZZZZ CLP-2 053(mm)110092012 0116

ZZZZZ CLP-1 053(mm)110092012 0116

PIBLK 460-13113718 CLP-2 053(mm)110092012 0131 vf479509d

PIBLK 460-13113718 CLP-1 053(mm)110092012 0131 vr479509d

CCV 460-13113719 CLP-2 053(mm)110092012 0147 vf479510d

CCV 460-13113719 CLP-1 053(mm)110092012 0147 vr479510d

8082

10162012Page 315 of 323

10162012Page 316 of 323

10162012Page 317 of 323

10162012Page 318 of 323

10162012Page 319 of 323

Lab Name Job No

SDG No

GC SEMI VOA BATCH WORKSHEET

460-45537-1

Batch Number Batch AnalystBatch Start Date

Batch End Date

Wu Huachi

100812 1800

100812 0754130997

Batch Method

TestAmerica Edison

3510C

Lab Sample ID Client Sample ID Method Chain Basis ReceivedpH InitialAmount FinalAmount OP_PCBSP 00024 OPPSTPCBSU 00021

AnalysisComment

7 1000 mL 5 mL 50 uL Acid Cleaning_UP

MB 460-1309971 3510C 8082

7 1000 mL 5 mL 50 uL 50 uL Acid Cleaning_UP

LCS 460-1309972

3510C 8082

7 1000 mL 5 mL 50 uL 50 uL Acid Cleaning_UP

LCSD 460-1309973

3510C 8082

WC-17338-100512-MW14-MM-251

7 980 mL 5 mL 50 uL Acid Cleaning_UP

460-45537-E-1 3510C 8082 T

WC-17338-100512-MW101-MM-252

7 990 mL 5 mL 50 uL Acid Cleaning_UP

460-45537-E-2 3510C 8082 T

Batch Notes

Batch Comment 8082Acid Cleaning_up Lot 20042

Persons name who did the concentration Wuh

Exchange Solvent Lot 6383

Exchange Solvent Name Hexane

Final Concentrator Volume 5 mL

N-evap temperature 35 Degrees C

Na2SO4 Lot Number 213204

Prep Solvent Lot 14764

Prep Solvent Name Mecl2

Prep Solvent Volume Used 180 ml mL

Persons name who did the prep Wuh

Persons name who witnessed reagent drop HCP

Basis Basis Description

T TotalNA

Page 1 of 18082

10162012Page 320 of 323

Shipping and

Receiving

Documents

10162012Page 321 of 323

10162012Page 322 of 323

Login Sample Receipt Checklist

Client Conestoga-Rovers amp Associates Inc Job Number 460-45537-1

Login Number 45537

Question Answer Comment

Creator Hall Alonzo

List Source TestAmerica Edison

List Number 1

NARadioactivity wasnt checked or is lt= background as measured by a survey

meter

NAThe coolers custody seal if present is intact Not present

TrueSample custody seals if present are intact

TrueThe cooler or samples do not appear to have been compromised or

tampered with

TrueSamples were received on ice

TrueCooler Temperature is acceptable

TrueCooler Temperature is recorded 32deg C IR 2

TrueCOC is present

TrueCOC is filled out in ink and legible

TrueCOC is filled out with all pertinent information

TrueIs the Field Samplers name present on COC

TrueThere are no discrepancies between the containers received and the COC

TrueSamples are received within Holding Time

TrueSample containers have legible labels

TrueContainers are not broken or leaking

TrueSample collection datetimes are provided

TrueAppropriate sample containers are used

TrueSample bottles are completely filled

TrueSample Preservation Verified

TrueThere is sufficient vol for all requested analyses incl any requested

MSMSDs

TrueContainers requiring zero headspace have no headspace or bubble is

lt6mm (14)

NAMultiphasic samples are not present

NASamples do not require splitting or compositing

NAResidual Chlorine Checked No analysis requiring residual chlorine check

assigned

TestAmerica Edison 10162012Page 323 of 323

  • Cover Title Page
  • Table of Contents
  • Data Summaries
    • Report Narrative
    • Sample Summary
    • Executive Summary
    • Method Summary
    • Method Analyst Summary
    • Sample Datasheets
    • Surrogate Summary
    • QC Data Summary
    • Data Qualifiers
    • QC Association Summary
    • Lab Chronicle
      • Organic Sample Data
        • GCMS VOA
          • Method 8260 DEL
            • Method 8260 DEL QC Summary
            • Method 8260 DEL Sample Data
            • Standards Data
              • Method 8260 DEL ICAL Data
              • Method 8260 DEL CCAL Data
                • Raw QC Data
                  • Method 8260 DEL Tune Data
                  • Method 8260 DEL Blank Data
                  • Method 8260 DEL LCSLCSD Data
                  • Method 8260 DEL MSMSD Data
                    • Method 8260 DEL Run Logs
                    • Method 8260 DEL Prep Data
                        • GC Semi VOA
                          • Method 8082 - Delaware
                            • Method 8082 - Delaware QC Summary
                            • Method 8082 - Delaware Sample Data
                            • Standards Data
                              • Method 8082 - Delaware ICAL Data
                              • Method 8082 - Delaware CCAL Data
                                • Raw QC Data
                                  • Method 8082 - Delaware Blank Data
                                  • Method 8082 - Delaware LCSLCSD Data
                                    • Method 8082 - Delaware Run Logs
                                    • Method 8082 - Delaware Prep Data
                                      • Shipping and Receiving Documents
                                        • Client Chain of Custody
                                        • Sample Receipt Checklist
Page 7: J45537-1 Nj Full Package Final Report
Page 8: J45537-1 Nj Full Package Final Report
Page 9: J45537-1 Nj Full Package Final Report
Page 10: J45537-1 Nj Full Package Final Report
Page 11: J45537-1 Nj Full Package Final Report
Page 12: J45537-1 Nj Full Package Final Report
Page 13: J45537-1 Nj Full Package Final Report
Page 14: J45537-1 Nj Full Package Final Report
Page 15: J45537-1 Nj Full Package Final Report
Page 16: J45537-1 Nj Full Package Final Report
Page 17: J45537-1 Nj Full Package Final Report
Page 18: J45537-1 Nj Full Package Final Report
Page 19: J45537-1 Nj Full Package Final Report
Page 20: J45537-1 Nj Full Package Final Report
Page 21: J45537-1 Nj Full Package Final Report
Page 22: J45537-1 Nj Full Package Final Report
Page 23: J45537-1 Nj Full Package Final Report
Page 24: J45537-1 Nj Full Package Final Report
Page 25: J45537-1 Nj Full Package Final Report
Page 26: J45537-1 Nj Full Package Final Report
Page 27: J45537-1 Nj Full Package Final Report
Page 28: J45537-1 Nj Full Package Final Report
Page 29: J45537-1 Nj Full Package Final Report
Page 30: J45537-1 Nj Full Package Final Report
Page 31: J45537-1 Nj Full Package Final Report
Page 32: J45537-1 Nj Full Package Final Report
Page 33: J45537-1 Nj Full Package Final Report
Page 34: J45537-1 Nj Full Package Final Report
Page 35: J45537-1 Nj Full Package Final Report
Page 36: J45537-1 Nj Full Package Final Report
Page 37: J45537-1 Nj Full Package Final Report
Page 38: J45537-1 Nj Full Package Final Report
Page 39: J45537-1 Nj Full Package Final Report
Page 40: J45537-1 Nj Full Package Final Report
Page 41: J45537-1 Nj Full Package Final Report
Page 42: J45537-1 Nj Full Package Final Report
Page 43: J45537-1 Nj Full Package Final Report
Page 44: J45537-1 Nj Full Package Final Report
Page 45: J45537-1 Nj Full Package Final Report
Page 46: J45537-1 Nj Full Package Final Report
Page 47: J45537-1 Nj Full Package Final Report
Page 48: J45537-1 Nj Full Package Final Report
Page 49: J45537-1 Nj Full Package Final Report
Page 50: J45537-1 Nj Full Package Final Report
Page 51: J45537-1 Nj Full Package Final Report
Page 52: J45537-1 Nj Full Package Final Report
Page 53: J45537-1 Nj Full Package Final Report
Page 54: J45537-1 Nj Full Package Final Report
Page 55: J45537-1 Nj Full Package Final Report
Page 56: J45537-1 Nj Full Package Final Report
Page 57: J45537-1 Nj Full Package Final Report
Page 58: J45537-1 Nj Full Package Final Report
Page 59: J45537-1 Nj Full Package Final Report
Page 60: J45537-1 Nj Full Package Final Report
Page 61: J45537-1 Nj Full Package Final Report
Page 62: J45537-1 Nj Full Package Final Report
Page 63: J45537-1 Nj Full Package Final Report
Page 64: J45537-1 Nj Full Package Final Report
Page 65: J45537-1 Nj Full Package Final Report
Page 66: J45537-1 Nj Full Package Final Report
Page 67: J45537-1 Nj Full Package Final Report
Page 68: J45537-1 Nj Full Package Final Report
Page 69: J45537-1 Nj Full Package Final Report
Page 70: J45537-1 Nj Full Package Final Report
Page 71: J45537-1 Nj Full Package Final Report
Page 72: J45537-1 Nj Full Package Final Report
Page 73: J45537-1 Nj Full Package Final Report
Page 74: J45537-1 Nj Full Package Final Report
Page 75: J45537-1 Nj Full Package Final Report
Page 76: J45537-1 Nj Full Package Final Report
Page 77: J45537-1 Nj Full Package Final Report
Page 78: J45537-1 Nj Full Package Final Report
Page 79: J45537-1 Nj Full Package Final Report
Page 80: J45537-1 Nj Full Package Final Report
Page 81: J45537-1 Nj Full Package Final Report
Page 82: J45537-1 Nj Full Package Final Report
Page 83: J45537-1 Nj Full Package Final Report
Page 84: J45537-1 Nj Full Package Final Report
Page 85: J45537-1 Nj Full Package Final Report
Page 86: J45537-1 Nj Full Package Final Report
Page 87: J45537-1 Nj Full Package Final Report
Page 88: J45537-1 Nj Full Package Final Report
Page 89: J45537-1 Nj Full Package Final Report
Page 90: J45537-1 Nj Full Package Final Report
Page 91: J45537-1 Nj Full Package Final Report
Page 92: J45537-1 Nj Full Package Final Report
Page 93: J45537-1 Nj Full Package Final Report
Page 94: J45537-1 Nj Full Package Final Report
Page 95: J45537-1 Nj Full Package Final Report
Page 96: J45537-1 Nj Full Package Final Report
Page 97: J45537-1 Nj Full Package Final Report
Page 98: J45537-1 Nj Full Package Final Report
Page 99: J45537-1 Nj Full Package Final Report
Page 100: J45537-1 Nj Full Package Final Report
Page 101: J45537-1 Nj Full Package Final Report
Page 102: J45537-1 Nj Full Package Final Report
Page 103: J45537-1 Nj Full Package Final Report
Page 104: J45537-1 Nj Full Package Final Report
Page 105: J45537-1 Nj Full Package Final Report
Page 106: J45537-1 Nj Full Package Final Report
Page 107: J45537-1 Nj Full Package Final Report
Page 108: J45537-1 Nj Full Package Final Report
Page 109: J45537-1 Nj Full Package Final Report
Page 110: J45537-1 Nj Full Package Final Report
Page 111: J45537-1 Nj Full Package Final Report
Page 112: J45537-1 Nj Full Package Final Report
Page 113: J45537-1 Nj Full Package Final Report
Page 114: J45537-1 Nj Full Package Final Report
Page 115: J45537-1 Nj Full Package Final Report
Page 116: J45537-1 Nj Full Package Final Report
Page 117: J45537-1 Nj Full Package Final Report
Page 118: J45537-1 Nj Full Package Final Report
Page 119: J45537-1 Nj Full Package Final Report
Page 120: J45537-1 Nj Full Package Final Report
Page 121: J45537-1 Nj Full Package Final Report
Page 122: J45537-1 Nj Full Package Final Report
Page 123: J45537-1 Nj Full Package Final Report
Page 124: J45537-1 Nj Full Package Final Report
Page 125: J45537-1 Nj Full Package Final Report
Page 126: J45537-1 Nj Full Package Final Report
Page 127: J45537-1 Nj Full Package Final Report
Page 128: J45537-1 Nj Full Package Final Report
Page 129: J45537-1 Nj Full Package Final Report
Page 130: J45537-1 Nj Full Package Final Report
Page 131: J45537-1 Nj Full Package Final Report
Page 132: J45537-1 Nj Full Package Final Report
Page 133: J45537-1 Nj Full Package Final Report
Page 134: J45537-1 Nj Full Package Final Report
Page 135: J45537-1 Nj Full Package Final Report
Page 136: J45537-1 Nj Full Package Final Report
Page 137: J45537-1 Nj Full Package Final Report
Page 138: J45537-1 Nj Full Package Final Report
Page 139: J45537-1 Nj Full Package Final Report
Page 140: J45537-1 Nj Full Package Final Report
Page 141: J45537-1 Nj Full Package Final Report
Page 142: J45537-1 Nj Full Package Final Report
Page 143: J45537-1 Nj Full Package Final Report
Page 144: J45537-1 Nj Full Package Final Report
Page 145: J45537-1 Nj Full Package Final Report
Page 146: J45537-1 Nj Full Package Final Report
Page 147: J45537-1 Nj Full Package Final Report
Page 148: J45537-1 Nj Full Package Final Report
Page 149: J45537-1 Nj Full Package Final Report
Page 150: J45537-1 Nj Full Package Final Report
Page 151: J45537-1 Nj Full Package Final Report
Page 152: J45537-1 Nj Full Package Final Report
Page 153: J45537-1 Nj Full Package Final Report
Page 154: J45537-1 Nj Full Package Final Report
Page 155: J45537-1 Nj Full Package Final Report
Page 156: J45537-1 Nj Full Package Final Report
Page 157: J45537-1 Nj Full Package Final Report
Page 158: J45537-1 Nj Full Package Final Report
Page 159: J45537-1 Nj Full Package Final Report
Page 160: J45537-1 Nj Full Package Final Report
Page 161: J45537-1 Nj Full Package Final Report
Page 162: J45537-1 Nj Full Package Final Report
Page 163: J45537-1 Nj Full Package Final Report
Page 164: J45537-1 Nj Full Package Final Report
Page 165: J45537-1 Nj Full Package Final Report
Page 166: J45537-1 Nj Full Package Final Report
Page 167: J45537-1 Nj Full Package Final Report
Page 168: J45537-1 Nj Full Package Final Report
Page 169: J45537-1 Nj Full Package Final Report
Page 170: J45537-1 Nj Full Package Final Report
Page 171: J45537-1 Nj Full Package Final Report
Page 172: J45537-1 Nj Full Package Final Report
Page 173: J45537-1 Nj Full Package Final Report
Page 174: J45537-1 Nj Full Package Final Report
Page 175: J45537-1 Nj Full Package Final Report
Page 176: J45537-1 Nj Full Package Final Report
Page 177: J45537-1 Nj Full Package Final Report
Page 178: J45537-1 Nj Full Package Final Report
Page 179: J45537-1 Nj Full Package Final Report
Page 180: J45537-1 Nj Full Package Final Report
Page 181: J45537-1 Nj Full Package Final Report
Page 182: J45537-1 Nj Full Package Final Report
Page 183: J45537-1 Nj Full Package Final Report
Page 184: J45537-1 Nj Full Package Final Report
Page 185: J45537-1 Nj Full Package Final Report
Page 186: J45537-1 Nj Full Package Final Report
Page 187: J45537-1 Nj Full Package Final Report
Page 188: J45537-1 Nj Full Package Final Report
Page 189: J45537-1 Nj Full Package Final Report
Page 190: J45537-1 Nj Full Package Final Report
Page 191: J45537-1 Nj Full Package Final Report
Page 192: J45537-1 Nj Full Package Final Report
Page 193: J45537-1 Nj Full Package Final Report
Page 194: J45537-1 Nj Full Package Final Report
Page 195: J45537-1 Nj Full Package Final Report
Page 196: J45537-1 Nj Full Package Final Report
Page 197: J45537-1 Nj Full Package Final Report
Page 198: J45537-1 Nj Full Package Final Report
Page 199: J45537-1 Nj Full Package Final Report
Page 200: J45537-1 Nj Full Package Final Report
Page 201: J45537-1 Nj Full Package Final Report
Page 202: J45537-1 Nj Full Package Final Report
Page 203: J45537-1 Nj Full Package Final Report
Page 204: J45537-1 Nj Full Package Final Report
Page 205: J45537-1 Nj Full Package Final Report
Page 206: J45537-1 Nj Full Package Final Report
Page 207: J45537-1 Nj Full Package Final Report
Page 208: J45537-1 Nj Full Package Final Report
Page 209: J45537-1 Nj Full Package Final Report
Page 210: J45537-1 Nj Full Package Final Report
Page 211: J45537-1 Nj Full Package Final Report
Page 212: J45537-1 Nj Full Package Final Report
Page 213: J45537-1 Nj Full Package Final Report
Page 214: J45537-1 Nj Full Package Final Report
Page 215: J45537-1 Nj Full Package Final Report
Page 216: J45537-1 Nj Full Package Final Report
Page 217: J45537-1 Nj Full Package Final Report
Page 218: J45537-1 Nj Full Package Final Report
Page 219: J45537-1 Nj Full Package Final Report
Page 220: J45537-1 Nj Full Package Final Report
Page 221: J45537-1 Nj Full Package Final Report
Page 222: J45537-1 Nj Full Package Final Report
Page 223: J45537-1 Nj Full Package Final Report
Page 224: J45537-1 Nj Full Package Final Report
Page 225: J45537-1 Nj Full Package Final Report
Page 226: J45537-1 Nj Full Package Final Report
Page 227: J45537-1 Nj Full Package Final Report
Page 228: J45537-1 Nj Full Package Final Report
Page 229: J45537-1 Nj Full Package Final Report
Page 230: J45537-1 Nj Full Package Final Report
Page 231: J45537-1 Nj Full Package Final Report
Page 232: J45537-1 Nj Full Package Final Report
Page 233: J45537-1 Nj Full Package Final Report
Page 234: J45537-1 Nj Full Package Final Report
Page 235: J45537-1 Nj Full Package Final Report
Page 236: J45537-1 Nj Full Package Final Report
Page 237: J45537-1 Nj Full Package Final Report
Page 238: J45537-1 Nj Full Package Final Report
Page 239: J45537-1 Nj Full Package Final Report
Page 240: J45537-1 Nj Full Package Final Report
Page 241: J45537-1 Nj Full Package Final Report
Page 242: J45537-1 Nj Full Package Final Report
Page 243: J45537-1 Nj Full Package Final Report
Page 244: J45537-1 Nj Full Package Final Report
Page 245: J45537-1 Nj Full Package Final Report
Page 246: J45537-1 Nj Full Package Final Report
Page 247: J45537-1 Nj Full Package Final Report
Page 248: J45537-1 Nj Full Package Final Report
Page 249: J45537-1 Nj Full Package Final Report
Page 250: J45537-1 Nj Full Package Final Report
Page 251: J45537-1 Nj Full Package Final Report
Page 252: J45537-1 Nj Full Package Final Report
Page 253: J45537-1 Nj Full Package Final Report
Page 254: J45537-1 Nj Full Package Final Report
Page 255: J45537-1 Nj Full Package Final Report
Page 256: J45537-1 Nj Full Package Final Report
Page 257: J45537-1 Nj Full Package Final Report
Page 258: J45537-1 Nj Full Package Final Report
Page 259: J45537-1 Nj Full Package Final Report
Page 260: J45537-1 Nj Full Package Final Report
Page 261: J45537-1 Nj Full Package Final Report
Page 262: J45537-1 Nj Full Package Final Report
Page 263: J45537-1 Nj Full Package Final Report
Page 264: J45537-1 Nj Full Package Final Report
Page 265: J45537-1 Nj Full Package Final Report
Page 266: J45537-1 Nj Full Package Final Report
Page 267: J45537-1 Nj Full Package Final Report
Page 268: J45537-1 Nj Full Package Final Report
Page 269: J45537-1 Nj Full Package Final Report
Page 270: J45537-1 Nj Full Package Final Report
Page 271: J45537-1 Nj Full Package Final Report
Page 272: J45537-1 Nj Full Package Final Report
Page 273: J45537-1 Nj Full Package Final Report
Page 274: J45537-1 Nj Full Package Final Report
Page 275: J45537-1 Nj Full Package Final Report
Page 276: J45537-1 Nj Full Package Final Report
Page 277: J45537-1 Nj Full Package Final Report
Page 278: J45537-1 Nj Full Package Final Report
Page 279: J45537-1 Nj Full Package Final Report
Page 280: J45537-1 Nj Full Package Final Report
Page 281: J45537-1 Nj Full Package Final Report
Page 282: J45537-1 Nj Full Package Final Report
Page 283: J45537-1 Nj Full Package Final Report
Page 284: J45537-1 Nj Full Package Final Report
Page 285: J45537-1 Nj Full Package Final Report
Page 286: J45537-1 Nj Full Package Final Report
Page 287: J45537-1 Nj Full Package Final Report
Page 288: J45537-1 Nj Full Package Final Report
Page 289: J45537-1 Nj Full Package Final Report
Page 290: J45537-1 Nj Full Package Final Report
Page 291: J45537-1 Nj Full Package Final Report
Page 292: J45537-1 Nj Full Package Final Report
Page 293: J45537-1 Nj Full Package Final Report
Page 294: J45537-1 Nj Full Package Final Report
Page 295: J45537-1 Nj Full Package Final Report
Page 296: J45537-1 Nj Full Package Final Report
Page 297: J45537-1 Nj Full Package Final Report
Page 298: J45537-1 Nj Full Package Final Report
Page 299: J45537-1 Nj Full Package Final Report
Page 300: J45537-1 Nj Full Package Final Report
Page 301: J45537-1 Nj Full Package Final Report
Page 302: J45537-1 Nj Full Package Final Report
Page 303: J45537-1 Nj Full Package Final Report
Page 304: J45537-1 Nj Full Package Final Report
Page 305: J45537-1 Nj Full Package Final Report
Page 306: J45537-1 Nj Full Package Final Report
Page 307: J45537-1 Nj Full Package Final Report
Page 308: J45537-1 Nj Full Package Final Report
Page 309: J45537-1 Nj Full Package Final Report
Page 310: J45537-1 Nj Full Package Final Report
Page 311: J45537-1 Nj Full Package Final Report
Page 312: J45537-1 Nj Full Package Final Report
Page 313: J45537-1 Nj Full Package Final Report
Page 314: J45537-1 Nj Full Package Final Report
Page 315: J45537-1 Nj Full Package Final Report
Page 316: J45537-1 Nj Full Package Final Report
Page 317: J45537-1 Nj Full Package Final Report
Page 318: J45537-1 Nj Full Package Final Report
Page 319: J45537-1 Nj Full Package Final Report
Page 320: J45537-1 Nj Full Package Final Report
Page 321: J45537-1 Nj Full Package Final Report
Page 322: J45537-1 Nj Full Package Final Report
Page 323: J45537-1 Nj Full Package Final Report