ivs sda-909 mounting-and-connections - rmg...

24
IVS SDA-909 Mounting and Connections

Upload: others

Post on 29-Jul-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

IVS SDA-909Mounting and

Connections

Page 2: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

NoticeCopyright © 2013 RMG Enterprise Solutions, Inc. All Rights Reserved.

This publication is protected by copyright and all rights are reserved. No part of this book may be reproduced or transmitted by any means or in any form, without prior written consent from RMG Enterprise Solutions, Inc.

The information in this publication has been carefully checked and is believed to be accurate. RMG Enterprise Solutions, Inc. assumes no liability for any inaccuracies that may be found in this publication.

In the interest of continued product development, RMG Enterprise Solutions, Inc. reserves the right to make improvements to this publication and the products it describes at any time without notice or obligation.

Publication DateRMGN-DOC-IVS-SDA-909-121213 cmgpdf-121213 December 2013

To access the latest version of this document, go to:

http://support.rmgnetworks.com/documentation/IVS_SDA-909_Mounting-and-Connections.pdf

2

Page 3: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

ContentsFCC Verification, Industry Canada & European CE Information . . . . . . 4

FCC . . . . . . . . . . . . . . . . . . . . . . . 4Industry Canada . . . . . . . . . . . . . . . . . . . 4

Important Safety Instructions . . . . . . . . . . . . . . . . . . . . 5Mounting the IVS SDA-909 . . . . . . . . . . . . . . . . . . . . . 6

Attaching the Mounting Plate . . . . . . . . . . . . . . . 7Simple Wall Mount . . . . . . . . . . . . . . . . . . . 8VESA-Compliant Display Mount . . . . . . . . . . . . . . 9

Connecting the IVS SDA-909 . . . . . . . . . . . . . . . . . . . . 12IVS SDA-909 Diagram. . . . . . . . . . . . . . . . . . 12Step-by-Step Connections for the IVS SDA-909 . . . . . . . . . 14

IVS SDA-909 Specifications . . . . . . . . . . . . . . . . . . . . . 15Physical Dimensions . . . . . . . . . . . . . . . . . . 15Hardware Components . . . . . . . . . . . . . . . . . 20Power Requirements . . . . . . . . . . . . . . . . . . 21Operating Specifications . . . . . . . . . . . . . . . . . 21

Getting Help and Support . . . . . . . . . . . . . . . . . . . . . . 22Contacting Technical Support . . . . . . . . . . . . . . . 22Accessing the RMG Networks Support Web Site . . . . . . . . . 22

3

Page 4: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

FCC Verification, Industry Canada & European CE Information

FCCThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

WARNING: Changes or modifications to this device not expressly approved by RMG Networks could void the user's authority to operate the equipment.

Industry CanadaThis Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions:

(1) this device may not cause harmful interference, and

(2) this device must accept any interference received, including interference that may cause undesired operation.

4

Page 5: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

Important Safety InstructionsThis device has undergone various tests in order to comply with safety standards. Inappropriate use may be dangerous. Please follow the instructions in this guide to ensure your safety during the installation and operation of the device. For safety and proper operation, keep in mind the following factors:

• It is important that your IVS SDA-909 be properly ventilated. Do not fully enclose the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or enclosure unless there are fans or a passive thermal exhaust that can constantly bring in new air to replace the trapped air in the space around the outside of the device.

• Place the IVS SDA-909 in a location free from dust and other particles.

• Ambient temperature should be between 32 °F to 104 °F (0 °C to +40 °C) in a non-condensing environment.

With the above factors in mind, please be aware of the following section from your hardware maintenance contract:

In the event that Hardware Maintenance is required due to: (i) abuse or mishandling of the Hardware by Customer, or (ii) any environmental conditions where the Hardware is located (dust, moisture, etc.), or (iii) any other technical issues (electrical “spikes” or the like), or (iv) any other external factors outside the normal operating conditions for the Hardware; then the charges for Maintenance associated therewith shall be paid by Customer.

5

Page 6: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

Mounting the IVS SDA-909The IVS SDA-909 includes hardware for installing the unit in a simple wall mount configuration or at the back of a VESA-compliant display. Do not throw away any cables, adapters, or other hardware that you might receive with the product—you may need them for future use if you should ever upgrade the IVS SDA-909.

(1) IVS SDA-909 Unit withMounting Plate & Screws Attached

(1) Power Cord (4) M9 Bolts

(1) Mounting Plate(2) WirelessAntennas

(2) Bracket Screws

PWR

HDD

6

Page 7: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

Attaching the Mounting PlateYou can attach the mounting plate to the IVS SDA-909 on either its top or bottom side. The orientation in which you want to mount the IVS SDA-909 determines which side to attach the mounting plate.

1. Slide the mounting plate so that the inner loop of the bracket is in line with the bracket screw in the left-most position on the IVS SDA-909.

2. Turn the spring-loaded screws on each side clockwise to secure the mounting plate to the IVS SDA-909.

PWR

HDD

Mounting Plate Attached to Bottom of IVS SDA-909

PWR

HDD

Mounting Plate Attached to Top of IVS SDA-909

1

v

v

2

7

Page 8: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

Simple Wall Mount

To install the IVS SDA-909 on a wall, position the unit so that the Power Button is on the bottom-side of the unit and the connections are on top. This allows the Power Button to be easily accessible from below, and the heat from the exhaust vents can rise above the unit.

1. Align the flat side of the mounting plate against the wall area where you want to install the IVS SDA-909.

2. Use four screws (not supplied) to attach the mounting plate to the wall.

3. Attach the IVS SDA-909 to the mounting plate using the steps on page 7.

4. (Optional) If you are using wireless communications, attach the two antennas to the connections at the top of the unit. (Pages 17 and 18 illustrate the space requirements for the antennas when fully extended or bent at a 90° angle.)

5. Refer to the instructions on page 12 to connectthe IVS SDA-909.

It is important that your IVS SDA-909 be properly ventilated and placed in alocation with the ambient temperature between 32 °F to 104 °F (0 °C to +40°C). See page 5 for specific details.

100-240VAC 50/60 Hz 1.3-0.8A

Power Button on Bottom

Connections on TopExhaust Vents

Leave antennas fully extended or

bend to 90°.

100-240VAC 50/60 Hz 1.3-0.8A

FIGURE 1. Simple Wall Mount

8

Page 9: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

VESA-Compliant Display Mount

The IVS SDA-909 mounting plate is compatible for mounting against the back of a display that has a 75 mm x 75 mm or 100 mm x 100 mm VESA MIS-D hole mount pattern. Use the hole mount pattern on the mounting plate that matches the pattern on the back of your display.

FIGURE 2. 75 mm x 75 mm and100 mm x 100 mm hole mount patterns

1. Position the mounting plate against the back of the display at the location where you want to mount the IVS SDA-909.

It is important that your IVS SDA-909 be properly ventilated and placed in alocation with the ambient temperature between 32 °F to 104 °F (0 °C to +40°C). See page 5 for specific details.

100 mm

100 mm

10

0 mm

75

mm

75 mm

75 m

m

75 mm

100

mm

9

Page 10: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

2. Use a Phillips screwdriver and four M9 bolts (supplied) to secure the mounting plate to the back of the display.

3. Attach the IVS SDA-909 to the mounting plate using the steps on page 7.

Note: Position the unit so that the Power Button is on the bottom-side of the unit and the connections are on top. This allows the Power Button to be easily accessible from below, and the heat from the exhaust vents can rise above the unit.

Connectionson TopExhaust Vents

Power Button on Bottom

10

Page 11: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

4. (Optional) If you are using wireless communications, attach the two antennas to the connections at the top of the unit. (Pages 17 and 18 illustrate the space requirements for the antennas when fully extended or bent at a 90° angle.)

FIGURE 3. VESA-Compliant Display Mount

Leave antennas fully extended or

bend to 90°.

11

Page 12: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

Connecting the IVS SDA-909

IVS SDA-909 DiagramThe following diagram demonstrates how to connect your IVS SDA-909 model. (A key to the numbered parts is shown in Table 1 on page 13.)

FIGURE 4. IVS SDA-909 Connections

Right Side ViewFront View

PWR

HDD

3

4

5

Back View

100-240VAC50/60 Hz1.3-0.8A

IOIOI

6 8a 8b

11 12

1

2a

9a

10 9b

7

v

Left Side View

2b13

12

Page 13: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

TABLE 1: IVS SDA-909 Functions Item # Description

1 USB 2.0 x (2)

2a, 2b Intake Vents

3 Power Indicator (White)

4 Power Button

5 HDD Indicator (Blue)

6 AC Input

7 RS-232 Serial Connector

8a, 8b Wireless Antenna Connectors

9a, 9b Exhaust Vents

10 USB 2.0 x (2)

11 HDMI Connectors x (2)

12 10/100/1000 Gigabit Ethernet Connector

13 Kensington Lock

13

Page 14: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

Step-by-Step Connections for the IVS SDA-909 Warning: Failure to set up your IVS SDA-909 sequentially according to the steps below may cause configuration difficulties or loss of functionality.

Refer to Figure 4 on page 12 for the following connections:

1. Insert a standard Ethernet cable into the Ethernet port (12).

2. The IVS SDA-909 supports one HDMI-to-HDMI output connection.

Connect the male end of an HDMI-to-HDMI cable (not supplied) to an HDMI connector (11) at the back of the IVS SDA-909. Connect the other end of the cable to an HDMI connector on a display device.

3. Connect the female end of the power cord to the three-prong connection at the back of the IVS SDA-909 (6). Plug the other end of the power cord into a standard AC outlet.

4. Briefly press the power button (4) on the IVS SDA-909. The SDA welcome message appears on the output screen.

Note: The first time you connect your SDA, the message “One Moment Please” may appear on the video display. Depending on your network, this message might appear for up to one minute. After that time a “Welcome” screen appears that displays the name of the SDA, its serial number, and the IP address that you'll need to set up your SDA. Use this IP address to access the Web Interface.

5. Refer to the following SDA configuration guide to configure your IVS SDA-909:

http://support.rmgnetworks.com/documentation/IVS_SDA_Configuration_v12.0.2.pdf

14

Page 15: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

IVS SDA-909 Specifications

Physical DimensionsWithout Antennas or Mounting PlateDimensions (W) x (H) x (D):165.1 mm x 41.28 mm x 108 mm(6.50” x 1.625” x 4.25”)

Weight: .90 kg (1 lb., 15.8 oz.)

165.1 mm(6.5")

41.2

8 m

m(1

.625

")

100-240VAC50/60 Hz1.3-0.8A

IOIOI

Back View

Front View

PWR

HDD

165.1 mm(6.5")

41.2

8 m

m(1

.625

")

15

Page 16: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

Right Side View

108 mm(4.25")

41.2

8 m

m(1

.62

5")

117.48 mm(4.625")

9.5 mm(.375")

v

Left Side View

108 mm(4.25")

41.2

8 mm

(1.62

5")

117.48 mm(4.625")

9.5 mm(.375")

16

Page 17: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

With Mounting Plate & Antennas Fully ExtendedDimensions (W) x (H) x (D):165.1 mm x 41.28 mm x 222.25 mm(6.5” x 1.625” x 8.757”)

Weight: 1.07 kg (2 lbs., 5.8 oz.)

Left Side View with Antennas Fully Extended

v

108 mm(4.25")

41.28 m

m(1.6

25")

6.35 mm(.25")47.625 mm

(1.875")47.625 mm

(1.875")

114.3 mm(4.5")

108 mm(4.25")

17

Page 18: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

With Mounting Plate & Antennas Bent at 90° Dimensions (W) x (H) x (D):166 mm x 95 mm x 194 mm(6.53” x 3.75” x 7.625”)

Weight: 1.07 kg (2 lbs., 5.8 oz.)

Left Side View with Antennas Bent 90°

6.35 mm(.25")

22.23 mm(.875")

85.7

25

mm

(3.3

75")

114.3 mm(4.5")

108 mm(4.25")

v

41.28

mm

(1.625

")

47.625 mm(1.875")

47.625 mm(1.875")

18

Page 19: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

With Mounting PlateDimensions (W) x (H) x (D):177.8 mm x 41.28 mm x 117.5 mm7.0” x 1.625” x 4.625”)

Weight: 1.05 kg (2 lbs., 5.1 oz.)

165.1 mm(6.5")

177.8 mm(7.0")

9.53 mm(.375")

6.35 mm(.25")

6.35 mm(.25")

Top View with Mounting Plate

108 m

m(4

.25")117

.5 m

m(4

.625

")

19

Page 20: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

Hardware Components

Front Panel IO

Power Button: x1

Disk Activity Indicator (blue): x1

Power indicator (white): x1

USB 2.0 Port: x2

Audio

Type: HDMI

LAN: 10/100/1000 Gigabit

Rear Panel IO

DC Jack: x1

HDMI port: x2

USB 2.0: x2

Serial DB9 (COM Port): x1 (For RS-232 Screen Control)

Wireless Antenna Connection: 802.11 a,b,g,n (2 x rear external antennas)

Kensington Lock Hole: x1 (side)

20

Page 21: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

Power Requirements

Operating Specifications

AC Input Frequency: 50/60Hz

AC Input Voltage: 100 ~ 240VAC

Current: 1.3-0.8A

Power Consumption: (Maximum) 42W

Air Flow Volume (cubic feet/minute): @ 50% System Loading 1.6CF,@ 100% System Loading 2.89CFM

Heat Dissipation: 143 BTU (Maximum)

Mean Time Between Failures (MTBF)

MTBF (Hour): 30,000 hours (continuous operation)

Noise: 28dB

Operating Temperature: 0 ~ 40ºC (32 ~ 104ºF)

Storage Temperature: -30 ~ 60ºC (-22 ~ 140ºF)

Relative Humidity: 95% RH (50ºC non-Condensing)

21

Page 22: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

Getting Help and Support

Contacting Technical Support

If you experience problems using your IVS SDA-909, please contact RMG Networks. Our main Web site is http://www.rmgnetworks.com.

• North American Customers - Contact RMG Networks Technical Support between 7:00 a.m. and 7:00 p.m., Central Standard Time (CST).Phone: 1-877-789-8324Fax: 1-972-535-0213Support E-mail: [email protected]

• International Customers - Contact RMG Networks Technical Support between 08:00 and 18:00, Greenwich Mean Time (GMT).Phone: +44 (0) 1442 275200Fax: +44 (0) 1442 275201Support E-mail: [email protected]

Accessing the RMG Networks Support Web Site

You can visit RMG Networks’s support web site athttp://support.rmgnetworks.com. There you can obtain answers to FAQs (frequently asked questions) and download product information.

22

Page 23: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or

Notes

23

Page 24: IVS SDA-909 Mounting-and-Connections - RMG Networkssupport.rmgnetworks.com/.../sda_connections/IVS_SDA... · the IVS SDA-909 in any type of recess, cabinet, kiosk, hole, nook, or