iso/iec 17025:2005 accredited calibration services · pdf file(973) 694-0500 • 4 iso/iec...

1
(973) 694-0500 www.belart.com/hb ISO/IEC 17025:2005 Accredited Calibration Services When Accuracy Counts, Over a Century of Experience is at Your Service! All calibrated instruments are provided with a Calibration Report from our exclusive triple accredited/registered manufacturing and calibration facility - ISO/IEC 17025:2005 through A2LA; ISO 9001:2008 and ISO 14001:2004. Each instrument is individually calibrated against National Institute of Standards and Technology (NIST) standards at specific temperature points. The report identifies corrections to one-tenth the smallest division. Each instrument is individually serialized to easily match the instrument and the report. Test procedures of NBS Monograph 150, 174 and ISO 17025 serve as guidelines for calibration. Thermometers and Hydrometers are calibrated NIST standards. Date of calibration (MM/DD/YYYY). ISO 17025:2005 accredited through A2LA. Internationally accepted through the ILAC MRA. Unique report number allows easy access to information. Serial number for instrument identification. General product description. Calibration Due Date NIST standard reading of calibration points. Actual test results for your instrument. Reference information for the unbroken chain of traceability to NIST. Tolerance or Accuracy of instrument tested Laboratory test conditions at time of Report. Indicates the expanded uncertainty and confidence level. “Double Checked” for accuracy.

Upload: nguyenque

Post on 04-Feb-2018

224 views

Category:

Documents


3 download

TRANSCRIPT

(973) 694-0500 • www.belar t .com/hb 4

ISO/IEC 17025:2005 Accredited Calibration ServicesWhen Accuracy Counts, Over a Century of Experience is at Your Service!

All calibrated instruments are provided with a Calibration Report from our exclusive triple accredited/registered manufacturing and calibration facility - ISO/IEC 17025:2005 through A2LA; ISO 9001:2008 and ISO 14001:2004. Each instrument is individually calibrated against National Institute of Standards and Technology (NIST) standards at specific temperature points. The report identifies corrections to one-tenth the smallest division. Each instrument is individually serialized to easily match the instrument and the report. Test procedures of NBS Monograph 150, 174 and ISO 17025 serve as guidelines for calibration.

Thermometers and Hydrometers are calibrated NIST standards.

Date of calibration(MM/DD/YYYY).

ISO 17025:2005 accredited through A2LA. Internationally accepted through the ILAC MRA.

Unique report number allows easy access to information.

Serial number for instrument identification.

General product description.

Calibration Due Date

NIST standard reading of calibration points.

Actual test results for your instrument.

Reference information for the unbroken chain of traceability to NIST.

Tolerance or Accuracy of instrument tested

Laboratory test conditions at time of Report.

Indicates the expanded uncertainty and confidence level.

“Double Checked” for accuracy.