is 11259 (1985): ink, numbering - public.resource.orgis:11259 - 1985 ( continued from page 1 )...

20
Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public. इंटरनेट मानक !ान $ एक न’ भारत का +नम-णSatyanarayan Gangaram Pitroda “Invent a New India Using Knowledge” प0रा1 को छोड न’ 5 तरफJawaharlal Nehru “Step Out From the Old to the New” जान1 का अ+धकार, जी1 का अ+धकारMazdoor Kisan Shakti Sangathan “The Right to Information, The Right to Live” !ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता ह Bharthari—Nītiśatakam “Knowledge is such a treasure which cannot be stolen” IS 11259 (1985): Ink, Numbering [CHD 14: Printing, Inks, Stationary and Allied Products]

Upload: others

Post on 26-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

Disclosure to Promote the Right To Information

Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public.

इंटरनेट मानक

“!ान $ एक न' भारत का +नम-ण”Satyanarayan Gangaram Pitroda

“Invent a New India Using Knowledge”

“प0रा1 को छोड न' 5 तरफ”Jawaharlal Nehru

“Step Out From the Old to the New”

“जान1 का अ+धकार, जी1 का अ+धकार”Mazdoor Kisan Shakti Sangathan

“The Right to Information, The Right to Live”

“!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता है”Bhartṛhari—Nītiśatakam

“Knowledge is such a treasure which cannot be stolen”

“Invent a New India Using Knowledge”

है”ह”ह

IS 11259 (1985): Ink, Numbering [CHD 14: Printing, Inks,Stationary and Allied Products]

Page 2: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-
Page 3: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-
Page 4: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-
Page 5: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS :11259 - 1985

Indian Standard SPECIFICATION FOR

INK, NUMBERING

Inks and Allied Products Sectional Committee, CDC 13

Chairman Representing

SARI N. G. MAITRA Sulekha Works Ltd, Calcutta

Members

SHRI J. A. ASTAPUTRE Ministry of Defence ( DGI ) SHRI K. P. MAJUMDA~ ( Alternate ) *

SHRI C. N. B~LAKRISHNAN Chemical Testing & Analytical Research Laboratory ( Department of Industries & Commerce, Government of Tamil Nadu ), Madras

SHRI I’. N. SUNDARA RAO ( Alternate ) SRRI N. S. BIRDIE Shri Ram Institute for Industrial Research, Delhi

SERI C. P. SHARD.~ ( Alternate ) SHBI S. CHANNIAR Associated Duplicator Company Pvt Ltd, Bangalore SHRI S. D. DA~JDEKAR Camlin Private Ltd, Bombay

SHEI R. M. DANDEKAI~ ( Alternate ) SHRI P. N. GANDHI Kores ( India ) Ltd, Bombay

DR T. R. BHASIBHANI ( Alternate ) JOINT DIRECTOR OF INDUSTRIES Department of Industries, Government of

Maharashtra, Bombay DEPUTY DIRECTOR OF

INDUSTRIES ( Alternate ) SHRI R. D. KAWATRA Directorate General of Technical Development,

New Delhi SHRI RANBIR KISHORE National Archives of India, New Delhi

SRRI RAJENDRA PR ASAD ( Alternate ) SHRJ M. R. KUMAR All India Federation of Master Printers, New Delhi

SHRI V. N. CHHABI~.~ ( Alternate ) SHRI G. P. MADAN Survey of India, Dehra Dun

SHRI S. K. SEN GUPTA ( Alternate ) SHRI A. M. MIRCHANDANI Chelpark Co Ltd, Bangalore

SHRI VASANTH ( Alternate ) SHRI H. MICRA Contgl;;;r& Stationery, Government of India,

SFIRI R. MURE~OPADHYAY Develtpment Commissioner ( Small Scale Industries), New Delhi

SARI P. S S~YANAR .%PANAN ( Alternate ) SHRI R. K. Nassau Bharat Carbon 8-z Ribbon Manufacturing Co Ltd,

New Delhi SERI SA~VESR NARAIN ( Alternate )

I @ Copyright 1985

( Continued on pugs 2 )

I INDIAN STANDARDS INSTITUTION

This publication is protected under the Zndian Copyright Act ( XIV of 1957 ) and reproduction in whole or in part by any means except with written permission of the publisher shall be deemed to be an infringement of copyright under the said Act.

Page 6: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS:11259 - 1985

( Continued from page 1 )

Members

SHRI K. L. NAILAYANSA Representing

Khoday Ribbon, Carbon & Allied Products Indus- tries, Bangalore

SHRI C. S. RI~ATTACIIAR,JEE ( Alternate ) SHRI P. K. PAIS National Test House, Calcutta DR J. RAJARA~X Rssen & Company, Bangalore

SHRI R. VISWAX.~~THAN ( Alternate ) SHRI N. P. S.4RNAlK India Security Press, Nasik Road

SXRI GANGA PILBKASH ( Alternate ) SI~RI V. N. SEHGAL

SHRI M. K. JAIN ( Alternafe ) Central Forensic Science Laboratory, New Delhi

SHRI S.K. SRJVASTAVA Coates of India Ltd, Calcutta DR C. S. CHADHA ( Alternate )

SRRIS. VENRATARAMAN Indian Duplicator Co Ltd, Calcutta SHRI A. K. SENGUPTA( Allernate)

SH~I SATISH CHANDER, Director General, IS1 ( &-o&o Member ) Director ( Chem )

Secretary

SHRI S. ARAVAMUDHAN Senior Deputy Director ( Chem ), IS1

Composition of Panel for Writing Inks, CDC 13 : P4

Convener

SIrRIN. C. bfAITRA Sulekha Works Ltd, Calcutta

Members

Dn S. D. NANDI (Afternate to Shri N. G. Maitra )

Snnr ACHAL Rr31.4~ AKORA Wisdom Ink Co, Delhi SHRI INDRAJIT ARORA ( Alternate 1

SHRI K. L. BIIARTL Hind Inks ( India ), Unnao SHRI S. R. BHAR’I’I ( Alternate )

SHRI R. M. D.~NDEIEAI~ Camlin Private Ltd, Bombay SARI P. W. LIMAYE ( Alternate )

THE DEPUTY DIRECTOR OF Department of Industries and Commerce, Madras INDUSTRIES & COEXMERCE, METALLURGICAL CHEMICAL LABORATORY

SHRI P. N. GANDHI Kores ( India ) Ltd, Bombay DR T. R. BHAMBI~ANI ( Alternate )

SHRI R. C. GUPTA National Archives of India, New Delhi SHRI V. V. TALWAR ( Alternate )

SHXI D. M. JOSKI Joshi Formulabes Pvt Ltd, Rajkot SHRI M. M. Ko~ncna ( Alternate )

SIIRI A. M. MIRCHANDANI SIII~I VAS~NTH ( Alternate )

Chelpark Company Ltd, Bangalore

( Continued on page 15 )

2

Page 7: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS : 11259 - 1985

Indian Standard SPECIFICATION FOR INK, NUMBERING

0. FOREWORD

0.1 This Indian Standard was adopted by the Indian Standards Institution on 4 March 1985, after the draft finalized by the Inks and Allied Products Sectional Committee had been approved by the Chemical Division Council.

0.2 For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, observed or calculated, expres- sing the result of a test or analysis, shall be rounded off in accordance with IS : Z-1960”. The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard.

1. SCOPE

1.1 This standard prescribes the requirements and the methods of sampling and test for numbering ink used for numbering letters, bills, names, etc, with the help of a numbering machine.

2. TYPES

2.1 This standard prescribes two types of numbering ink as follows:

=Y@ 1 - Numbering ink of black colour.

Type 2 - Numbering ink of colour other than black.

3. REQUIREMENTS

3.1 Description - The material shall consist of a dispersion of pigment with or without admixture of other pigments or dyestuff in a suitable base. The impression shall be intense and bright, shall not dry in the machine. The impressions shall adhere to the paper and shall not penetrate to the other side to such an extent as to spoil the matter printed/hand written on the other side.

*Rules for rounding off numerical values ( raised ).

3

Page 8: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS : 11259 - 1985

3.1.1 The material shall be of uniform consistency, free from grit and shall not corrode the numbering machine.

3.1.2 The material shall be free from any objectionable odour or obnoxious smell.

3.1.3 The material shall be free flowing. It shall not ooze out from the numbering machine, when in use or not.

3.2 Pigment Content - The material, when tested by the method prescribed in Appendix A, shall contain:

a) not less than 16 percent pigment by mass in case of Type 1, and

b) not less than 20 percent pigment by mass in case of Type 2.

3.3 Fineness of Dispersion - The ink shall be free from any gritty particles and shall not be coarser than 10 microns on the Hegmen scale or equivalent when tested by the method prescribed in Appendix B.

3.4 Viscosity - The viscosity of the ink for the first 50 ml shall be as follows when tested at 27°C by the method prescribed in Appendix C.

a) 25 to 30 seconds for Type 1, and

b) 10 to 12 seconds for Type 2.

3.5 Relative Density - The relative density of the ink shall be O-980 to 0.995 when tested at 27°C by the method prescribed in Appendix D.

3.6 Drying Time - The material shall dry within 15 seconds when tested by a numbering machine on manifolding paper ( 30 to 34 g/mz ) and impressions shall not smudge when rubbed gently with a finger.

3.7 Keeping Quality - The material when stored under normal conditions in sealed container shall retain the properties detailed in the specification for a minimum period of 2 years from the date of manufac- ture.

4. PACKING

4.1 The material shall be packed in securely closed containers as agreed to between the purchaser and the manufacturer.

5. MARKING

5.1 The container shall be marked legibly with the following particulars:

a) Name and type of the material;

b) Manufacturer’s name and/or his registered trade-mark, if any;

c) Mass of the material;

4

Page 9: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS : 11259 - 1985

d) Month and year of packing; and

e) Batch number to enable the date of manufacture to be traced from records.

5.2 The containers may also be marked lvith the IS1 Certification Mark.

NOTE - The uw of the IS1 Certification Mark i’ \ governed by the provisions of the Indian Standards Institution ( Certification Marks ) Act and the Rules and Regulations made thereunder. The ISI Mark on products covered by an Indian Standard conveys the assurance that they have been produced to comply with the requirements of that standard under a well-defined system of inspection, testing and quality control which is devised and supervised by TSI and operated by the producer. IS1 marked products are also continuously checked by IS1 for conformity to that standard as a further safeguard. Details of conditions under which a licence for the use of the IS1 Certification Mark may be granted to manufacturers or processors, may be obtained from the Indian Standards Institution.

6. SAMPLING

6.1 The method of drawing representative samples, number of samples

to be tested and the criteria for conformity shall be as prescribed in

Appendix E.

APPEND1.X A ( Clause 3.2 )

DETERMINATION OF PIGMENT CONTENT

A-O. Outline of the Method - The pigment content is determined by treating the material with extraction mixture and then separating it in a centrifuge and drying.

A-l. PROCEDURE

A-l.1 Pigment Content - Weigh accurately 15 to 20 g of the well mixed material into a weighed centrifuge tube. Add 20 to 30 ml of appropriate extraction mixture mentioned below and mix thoroughly using a glass rod:

a) Benzene - 5 parts by volume (see IS : 534-1974* ) Methyl alcohol - 4 parts by volume p;;tt;,: 517-1967t )

- 1 part by volume (see IS : 17O-1976: )

dehydrated over ’ sodium sulphate

*Specification for benzene ( second revision ). tspecification methanol ( methyl alcohol ) (jirst revision ). &Specification for acetone ( second revision ).

5

Page 10: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS : 11259 - 1985

This solvent mixture ensures maximum retention of pigment but does not fully extract resins and bodied oils.

b) A mixture of equal parts of benzene and petroleum hydrocarbon solvent 1451205 low aromatic ( see IS : 1745-1978* ). This is a good solvent for resins and bodied oils, but extra fine pigments do not settle well in this mixture.

c) A suitabie mixture of solvents (a) and (b) above. This is recom- mended for material containing resins and bodied oils.

After mixing, rinse-the glass rod thoroughIy with the extraction mixture in the centrifuge tube. Fill the tube and place it in the container of the centrifuge, counterbalance the container of the opposite arm and whirl at a minimum speed of 3000 rev/min, until maximum separation is effected. Decant the liquid and repeat the process twice or more, if required. Keep all the extracted liquid in a weighed 250-ml conical flask. Place the tube containing the pigment on the top of the air-oven for half an hour for the solvents to escape and then inside the oven maintained at 100 f 2°C and weigh after drying to constant mass.

APPENDIX B ( Clause 3.3 )

DETERMINATION OF FINENESS OF DISPERSION

El. GENERAL

R-l.0 Fineness of dispersion is measured on a grind gauge?, consisting of a block of hardened steel into which has been machined a shallow groove varying in depth from zero at one end to 0.102 mm at the other. A sample of ink is placed at the deep end and is drawn down towards the shallow end by a steel scraper. Observation of any scratches in the ink film, and where they occur in terms of distance along the gauge, gives a measure of the degree of dispersion of the ink sample.

B-2. APPARATUS

B-2.1 Gauget - A hardened steel block approximately 180 mm in length, 63.5 mm in width and 12.5 mm in thickness. The top surface of the block shall be ground smooth and flat, and shall contain a groove 133.4 mm in length and 12.5 mm in width, centred in the top of the block. The groove shall be tapered uniformly in depth lengthwise from

*Specification for petroleum hydrocarbon solvents ( second mision ). $Generaliy known as Hegman gauge.

6

Page 11: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS:11259 - 1385

0,102 mm at one end to zero depth at the other, calibrdted with a scale number in accordance with its depth as given in Table 1.

NOTE-The apparatus may also be of a double channel type fcr comparing another sample.

_-

TABLE 1 RELATIONSHIP BETWEEN DEPTH OF TAPERED GROOVE AND SCALE FOR FINENESS OF GRINDING

( Clause B-2.1 )

DISTAPI’CE FROM ZERO F&m

mm

133.350

127~000

111.125

95.250

79.375

63.500

47.625

3 I.730

15.875

0

DEPTH

microns

102

102

89

76

61

51

38

25

13

0

EiEGMAN SCALE

Well for snmple

0

1

2

3

4

5

6

7

8

B-2.2 Scraper - A double-edged steel blade 87.5 mm long, 37.5 mm wide and 6.8 mm thick. The two edges along the length shall be rounded to a radius of approximately 0.25 mm.

B-3. PROCEDURE

B-3.1 This consists of the following steps:

4

b)

cl

PJace the gauge on a flat, nonslippery surface and wipe it clean immediately before the test.

Place the material to be tested in the deep end of the groove so that it overflows the groove slightly. Care shall be taken to see that the sample is free of air bubbles.

Using both hands, hold the blade perpendicular to the block surface and at right angles to the length of the groove, draw the material down the length of the groove with a uniform deliberate motion. Use sufficient pressure to clean the level face of the gauge.

7

Page 12: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS : 11259 - 1985

d) Immediately read the fineness as follows:

1) View the gauge from the side so that the line of vision is at right angles to the longer dimension of the groove.

2) Hold the gauge in light that will make the pattern readily visible.

3) For actual reading, make the angle between the face of the gauge and the line of vision not more than 30” nor less than 20”.

4) Interpret the pattern and designate dispersion in microns or scale number, ignoring the few isolated and irregularly spaced particles towards the deep end of the groove.

Using a fresh sample of the material each time, obtain three readings in the like manner. The first drawdown and reading is preliminary in order to establish proper conditions and to locate fineness pattern. With this known, the second and third readings can be made with a minimum time lapse between completion of drawdown and actual reading. No reading shall be considered for reporting fineness when the time lapse exceeds 10 seconds.

B-3.2 Care of Gauge

4

4

The gauge shall be immediately cleaned after each reading. Use a solvent and a soft cioth. Keep the gauge covered at all times when not in use. Gauges that lie idle for extended periods of time shall be protected from rust.

Do not allow any hard materials to come in contact with the gauge surface or scraper in any manner that might result in scarring or nicking. Tapping or scratching with other metallic surfaces shall be avoided.

c) The scraper e dgeY

may be rendered unsatisfactory for !.tse by wear of the contact edge or by warpage.

NOTE - Wear or warpage of the scraper may be noted by facing the edge of the scraper down on the smooth level face of the gauge and then inspecting the contact edge by means of a strong light, placed behind the gauge. Rocking the scraper forward or backward will reveal poor contact due to wear or warpage. shows that the scraper has been damaged, it shall not be used.

If any face

Page 13: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS: 11259 - 1985

APPENDIX C ( Clause 3.4 )

DETERMINATION OF VISCOSITY

C-l. APPARATUS

a) The flow cup* shall be essentially of the form and dimensions as shown in Fig. 1.

All dimensions in millimetres.

FIG. 1 FLOW CUP

b) Material of Comtruction - A cup made of any non-ferrous material is suitable. This may be plated. The finish shall be smooth. The jet may be either bored directly or constructed separately of stainless steel and force fitted. Care is essential in order to avoid damage to the lower apex of the cup. A protective skirt which does not interfere with the flow may be provided.

*Generally known as Ford cup viscometer No. 4.

9

Page 14: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS : 11259 - 1985

c) The following additional apparatus shall also be required in carrying out the test:

1) A thermometer accurate to within 0.5”C;

2) A stop-watch or stop-clock;

3) A suitable stand provided with levelling screws;

4) A spirit !evel; and

5) A straight-edged scrapper for the top of the cup..

C-2. PROCEDURE

C-2.1 Place the flow cup on the stand in a place free from draughts, preferably with the air temperature within the range of 27 Ik 2°C and level by using of a spirit level placed on the rim.

a>

b)

Cl

. 4

Strain the sample into a clean container and adjust the temper- ature to meet the requirements as specified in C-2.1(c). A 150-micron IS Sieve [see IS : 460 (Part 1 )-1978” ] or finer, is suitable. This and the following operations shall be carried out with minimum delay to avoid loss of solvent.

With the orifice closed by the finger, fill the cup with the bubble- free sample until it just begins to overflow into the gallery, pouring slowly to minimize the formation of air bubbles. If’ bubb- les are present, allow them to rise and then remove them from the surface.

Check that the temperature of the material in the cup is within 0*5”C of the test temperature. The cup may be at a temperature different from that of the sample and it is recommended that a minute or so be allowed to elapse before checking the temper- ature. Place the scraper on the rim of the cap and draw it firmly across until the excess of the sample has flowed into the gallery. Place the receiver under the cup. Remove the finger and simultane- ously start the stop-watch. Watch the steam of liquid flowing from the orifice. At the first evidence of a break of the stream into droplets, stop the stop-watch. The time taken is recorded in seconds as time of flow in the ilow cup.

- *Specification for test sieves : Part 1 Wire cloth test sieves ( second rcvisiun ).

10

Page 15: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS:11259 - 1985

APPENDIX D ( Clause 3.5 )

DETERMINATION OF RELATIVE DENSITY

D-l. DEFINITION

D-l.1 For the purpose of this standard, the relative density of the material is the ratio of the mass of a given volume of the material to that of an equal volume of distilled water, the temperature of both the material and the water being 27°C.

D-2. APPARATUS

D-2.1 Hubbard Relative Density Bottle ( Modified ) - see Type 6 of IS : 5717-1970*.

D-3. PROCEDURE

D-3.1 Clean, dry and weigh the bottle and the stopper. Fill with water at a temperature of about 25”C, introduce the stopper and keep in a water bath at 27°C for 15 minutes. Wipe off all surplus water from the surface with a soft, clean and dry cloth and weigh again. Empty the bottle, clean and dry and repeat the operations after filling it with the material.

D-4. CALCULATION

D-4.1 Relative density at 27°C = M, - M M

1- M

where

M2 = mass in g of the reIative density bottle filled with the material,

M = mass in g of the dry relative density bottle, and

Ml = mass in g of the relative density bottle filled with distilled water.

*Specification for pyknometers.

11

Page 16: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS : 11259 - 1985

APPENDIX E ( Clause 6.1 )

METHOD OF SAMPLING INK, NUMBERING

E-l. GENERAL REQUIREMENTS OF SAMPLING

E-l.1 Drawing, preparing, storing and handling of test samples, shall be done in accordance with IS : 8883 ( Part 1 )-1978*.

E-1.2 The sampling apparatus shall be clean and dry when used.

E-l.3 Precautions shall be taken to protect the samples, the material being sampled, the sampling apparatus and the containers for samples from adventitious contamination.

E-l.4 The samples shall be kept in clean, dry airtight glass or other suitable containers on which the material has no action.

E-l.5 The sample containers shall be of such a size that they are almost completely filled by the sample.

E-1.6 Each sample container shall be sealed airtight with a stopper after filling, and marked with full details of sampling, the date of sampling and the month and year of manufacture of the material.

E-1.7 Samples shall be stored in such a manner that the temperature of the material does not vary unduly from the normal temperature.

E-2. SCALE OF SAMPLING

E-2.1 All the tubes in a single consignment of the material drawn from a single batch of manufacture shall constitute a lot. If a consignment is declared or known to consist of different batches of manufacture, the tubes belonging to the same batch shall be grouped together and each such group shall constitute a separate lot.

E-2.1.1 Samples shall be tested from each lot separately for ascertain- ing the conformity of the material to the requirements of the specifica- tion.

E-2.2 The number of tubes to be chosen from the lot shall dependon the size of the lot and shall be in accordance with Table 2.

E-2.3 These tubes shall be chosen at random from the lot and in order to ensure the randomness of selection, a random number table shall be used. For guidance and use of random number table, IS : 4905-19681_

*Methods of sampling chemical products: Part 1 General requirements and precautions.

tMethod for random sampling.

12

Page 17: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS :11259-1985

TABLE 2 NUMBER OF TUBES TO BE SELECTED FOR SAMPLING

( Clause E-2.2 )

LOT SIZE No. OF CONTAINERS TO BE CHOSEN

WI (4

Upto 15 3

16to 50 4 51 to 100 5

101 and above 7

may be referred. In the absence of random number table, the following procedure may be adopted:

Starting from any tube in the lot, count them as 1,2,3 ,... . . . . . . etc, up to r and so on. Every rth tube thus counted shall be withdrawn from the lot to give a sample for test, where r is the integral part of N/n, N being the total number of tubes in the lot and n the number of tubes to be chosen.

E-3. TEST SAMPLES AND REFEREE SAMPLE

E-3.1 Preparation of Test Samples

E-3.1.1 Take a small portion of the material from each container selected ( see Table 2 ), Thoroughly mix the material before drawing from the same container. Out of these portions, a small but equal quantity shall be taken for each selected container and shall be well mixed up together so as to form a composite sample of quantity sufficient to make triplicate determination for all the characteristics to be tested on the composite sample. This composite sample shal! be divided into three equal parts, one for the purchaser, another for the supplier and the third for the referee.

E-3.2 Referee Sample

E-3.2.1 Referee sample shall consist of the composite sample ( see E-3.1.1 ) and marked for the purpose and shall bear the seals of the purchaser and the supplier. This shall be kept at a place agreed to between the purchaser and the supplier and shall be used in case of a dispute between the two.

E-4. NUMBER OF TESTS

E-4.1 Tests for the determination of all characteristics mentioned in 3 shall be conducted on the composite sample.

13

Page 18: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS:11259 - 1985

E-5. CRITERIA FOR CONFORMITY

E-5.1 A lot shall be declared as conforming to the specification if it satisfies the requirements for each of the characteristics mentioned in this specification.

E-5.2 If the requirements for any of the characteristics are not met, the lot shall be declared to have not satisfied the requirements of the specification and shall be rejected.

14

Page 19: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

IS : 11259 - 1985

( Continued from page 2 )

Members Representing

SHBIH.&fITRA Contr$:;;tt;f Stationery, Government of India,

SHRI S.B.BANDOPADHYAY (A~~muz~ca) SHRIR.V.SUBBARAO Krishnaveri Ink Factory, Madras DRS. SAHA Directorate of Industries, Government of West

Bengal, Calcutta DR A. SEN ( Alternate )

SHRI V. N. SEHQAL Central Forensic Science Laboratory, New Delhi SHRI M. K. JAIN ( Alfernatc )

SRRIR.SETHURAMAN Industrial Research Corporation, Bangalore SHRI R.~ISWANATHAN( Alternate)

15

Page 20: IS 11259 (1985): Ink, Numbering - Public.Resource.OrgIS:11259 - 1985 ( Continued from page 1 ) Members SHRI K. L. NAILAYANSA Representing Khoday Ribbon, Carbon & Allied Products Indus-

INTERNATIONAL SYSTEM OF UNITS ( SI UNITS )

Base Units

@ANTITY

Length

Mass

Time

Electric current

Thermodynamic temperature

Luminous intensity

Amount of substance

Supplementary Unita

QUANRTV

Plane angle

Solid angle

Derived Unita

UNIT

metre

kilogram

second

ampere

kelvin

candela

mole

UN17

radian

steradian

QUANTITY UNIT

Farce

Energy

Power

Flux

Flux density

Frequency

Electric Conductance

Electromotive force

Pressure, stress

newton

joule

watt

weber

tesla

hertz

siemens

volt

Pascal

SYM HU‘

m

k% s

A

K

cd

rnol

SYIROL

: W

Wb

T

HZ

s

V

Pa

1 N = 1 kg.m/s”

1 J = 1 N.m

I W = 1 J/s

1 Wb = 1 v.s

1 T = 1 Wb/ms

I Hz = 1 c/s (s-l)

I S = 1 A/V

I v 3 I W/A

1 Pa = 1 N/m?