IRA-4SS Automatic Insertion Instrument Regulator Features ! ! ! ! ! ! ! ! ! Patented Automatic Insertion Device allows insertion and removal of the probe from a high pressure pipeline through a full open isolation valve without pipeline shutdown (specify insertion length). Provides a regulated sample supply to chromatographs, H S analyzers, gravitometers, calorimeters, moisture analyzers, and other on-line analyzing equipment. Diaphragm design for increased low pressure output sensitivity. Probe design inhibits carry-over of free liquids into instrument supply system. Thermal fins on probe offset temperature change at point of regulation and provide sample conditioning. 316 stainless steel construction. Manufactured under U.S. Patent #4,346,611. Oil pot for smooth and safe insertion and retraction. Range springs available for 0-25 psi (0-1.7 Bar), 0-50 psi (0-3.5 2 Welker Probe Regulators are designed to provide your chromatograph, H S analyzer, thermtitrator, moisture analyzers, gravitometer, calorimeter, or other on-line gas analyzers with a properly conditioned sample stream. These regulators are designed with the point of regulation near the tip of the probe in the flowing stream. The natural temperature drop that occurs at the point of regulation (Joule-Thomson effect) is offset by the thermal fins on the probe tip. When used with an isolation valve, the IRA-4SS can be completely installed or removed without interrupting pipeline flow or operations. The IRA-4SS is another designed to improve the profitability of your company. 2 Welker Innovative and Patented Product TYPICAL INSTALLATION Sample Conditioning System Analytical Equipment (Chromatograph) Outlet Gauge Port High Capacity Relief Port Length to specify with order Full Open Isolation Valve (O 1" Internal Min.) Probe tip should be in the center 1/3 of the pipe Engineering Company I S O - 9 0 0 1 C e r t i f i e d Si n c e 1 9 9 2

Upload: ruben-ortiz-caram

Post on 18-Aug-2015

233 views

Category:

Documents


0 download

DESCRIPTION

IRA4SS

TRANSCRIPT

IRA-4SS Automatic Insertion Instrument RegulatorFeatures!!!!!!!!!Patented Automatic Insertion Device allows insertion andremoval of the probe from a high pressure pipeline through afullopen isolation valve without pipeline shutdown (specify insertionlength).Provides a regulated sample supply to chromatographs, H Sanalyzers, gravitometers, calorimeters, moisture analyzers, andother on-line analyzing equipment.Diaphragm design for increased low pressure output sensitivity.Probe design inhibits carry-over of free liquids into instrumentsupply system.Thermal fins on probe offset temperature change at point ofregulation and provide sample conditioning.316 stainless steel construction.Manufactured under U.S. Patent #4,346,611.Oil pot for smooth and safe insertion and retraction.Range springs available for 0-25 psi (0-1.7 Bar), 0-50 psi (0-3.52Welker Probe Regulators are designed to provide your chromatograph, H S analyzer, thermtitrator,moisture analyzers, gravitometer, calorimeter, or other on-line gas analyzers with a properlyconditioned sample stream. These regulators are designed with the point of regulation near the tip ofthe probe in the flowing stream. The natural temperature drop that occurs at the point of regulation(Joule-Thomson effect) is offset by the thermal fins on the probe tip. When used with an isolationvalve, the IRA-4SS can be completely installed or removed without interrupting pipeline flow oroperations. The IRA-4SS is another designed toimprove the profitability of your company.2Welker Innovative and Patented ProductTYPICAL INSTALLATIONSample Conditioning SystemAnalyticalEquipment(Chromatograph)OutletGaugePortHighCapacityReliefPortLength tospecify withorderFull OpenIsolation Valve(O 1" Internal Min.)Probe tip should bein the center 1/3 ofthe pipeEngineering CompanyISO- 9001CertifiedSince1992P.O. Box 138Sugar Land, Texas77487-01381 (281) 491-23311-800-PRO-SAMPInternational Fax: 1 (281) 242-5623Domestic Fax: 1 (281) 491-8344WELKER ... When excellence counts!Engineering [email protected] A (6/97)IRA-4SS.CDRApplicationPressure RatingTemperature RatingInsertion LengthFlow DataThe IRA-4SS can be used with all products thatare compatible with the materials of constructionand seal material. High capacity downstreamrelief is recommended.Line pressures up to 2160 psi (149 Bar). Higherpressure ratings available. Outlet pressureranges 0-25 psi (0-1.7 Bar), 0-50 psi (0-3.5 Bar),and 20-100 psi (1.4-6.9 Bar).From -20 to +400F (-29 to +204C).18" (457 mm) insertion travel standard, otherinsertion lengths available in 6" (152 mm)increments.C - .092.Inlet Filter30-35 Micron.o oVMaterialsConnectionsWeight (Standard 1" NPT, 18" insertion)Options Available (not limited to)316 stainless steel construction with Viton sealsand PTFE seats for pressure under 1800 psi (124Bar). Over 1800 psi, seat is Kel-f material.Pipeline connections are 1" MNPT standard withflange connections available upon request.Outlet, gauge and relief valve connections are "FNPT.16 lbs.7.2 Kg.Non-standard designs available uponrequestOther materials available!!!2", 3" or 4" flanged connections 300#, 600#,900#, or 1500# RF/RTJWorking pressure up to 5000 psi (345 Bar)Certificates (material 3.1B, hydro,functional, conformity, etc.)Automatic Liquid Shut-OffVent Check ValvesLiquid EliminatorsFiltersSampling SystemsChemical Injection SystemsControl ValvesCustom Designs!!!!!!!!!Other Welker ProductsTechnical Data(Standard)Distributed By:" NPTGaugePort" NPT PortOil Pot1" NPTPipelineConnectionStandardThermalFins47" for 18" Insertion(fully retracted)(1194 mm)Probe Tip O.D.0.7" (17 mm)" NPT ReliefValve Port(not shown)Insertion LengthAdjustment Collar