Page 1: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

Ion Beam Analysis of Gold Flecks in a Foam Lattice

F E Gauntlett, A S Clough

Physics Department, University of Surrey, Guildford, GU2 7XH, UK

Page 2: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

General Background• Clumpiness of the interstellar medium may play an important role in the transfer of infrared continuum radiation in star forming regions• Laboratory experiments have started, using high power laser facilities, to create clumpy media in the form of inhomogeneous plasmas to allow the testing of models of radiation transport

Laser heated hohlraum

Low density foam cylinder (1mm diameter 1mm) loaded with tiny gold spheres (~ 5 m diameter)

Page 3: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

Ion Beam Characterisation of the gold-loaded foam

At Surrey we have been asked to measure:

• the mass of the gold in the foam

• the average size of the flecks

•the uniformity of distribution of the flecks.

Facility: 2 MV Tandetron

Beamline: Scanning in vacuo proton microbeam

Techniques: Scanning Micro-PIXE

Scanning Micro-RBS

Sample: Gold loaded foam cylinder

Comparison sample: 2 m thick gold foil

Page 4: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

DetectorsAt Ep ~ 4 MeV Au L X-rays (~ 10 keV) are produced in abundance but they are attenuated by ~ 35% in a 5 m diameter gold fleck.

Au K X-rays have energies of 66 – 78 keV but their yield is low. However they are only attenuated by ~ 1%.

Thus we need to detect both K X-rays to determine the overall quantity of gold present and L X-rays to determine from the

attenuation the average size of the flecks.

Hence we use eV Products CdTe detectors which are ~100% efficient between 10-70 keV.

We also detect Backscattered protons with 100 sq mm ORTEC ULTRA detectors with a 300 m depletion layer.

We use two detectors in both cases to obviate any instrumental asymmetries.

Page 5: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

Overhead view of sample chamber

Page 6: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

View of vertical sample holder , sample in carbon blocks and beam setting up plate

Page 7: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

View of sample in the chamber through microscope at 135 to beam direction

Page 8: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

RBS detector spectrum from foam containing gold flecks

Carbon edge

Oxygen edge

Gold continuum

Page 9: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

Gold continuum

Page 10: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

165O

to detector

protons

How do we explain the shape of the gold continuum?

Assuming gold flecks are 5m in diameter and have a total mass of 15% of the foam mass – an upper estimate, the number of gold flecks in a cylinder is ~700 and the areal ratio (sum of cross sectional areas of gold spheres/area of foam cylinder) ~7x10-2 i.e. 93% of the time protons in the beam incident on the foam go through the foam completely missing any gold flecks.

It is likely that at most only 1 gold fleck is in the path of a proton.

Page 11: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

At the highest backscatter detected energy (~4.05 MeV)only the front surface nuclei of the gold fleck at the left-hand edge will contribute. The Limiting Depth is when the backscatter energy from the front of a Au fleck there is equal to the backscatter energy from Oxygen at the front of the foam (~3.23 MeV). Contributions from different flecks at this backscatter energy are shown. At backscatter energies between 3.23 and 4.05 MeV fewer and fewer flecks contribute –giving the Au backscatter spectrum we observe

Limiting Depth, DL

Page 12: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

For 4 MeV protons DL~0.7mm.

Thus to detect all the gold flecks in the foam to a depth of 1 mm with 4 MeV protons we detect X-rays.

X-ray detector spectrum (Au L region) from foam with gold flecks

Page 13: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

X-ray detector spectrum (Au K region) from foam with gold flecks

Page 14: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

Au RBS top AuL PIXE right O RBS top AuK PIXE right

Au RBS btm AuL PIXE left O RBS btm AuK PIXE left

Page 15: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough
Page 16: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

Can we get an estimate of the gold mass?

Backscatter spectra from the foam surrounds

Top detector Bottom detector

Counts per unit area

Page 17: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

Taking a section of the carbon we measure carbon counts per unit area in a section of the spectrum

NCS/ACS

Page 18: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

Taking a separate run on the gold foil and adjacent carbon and software excluding the gold:

Position of gold foil

Position of Carbon

Related Carbon BS spectrum

From this we get NCF/ ACF

Page 19: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

We then get an excellent measure of the beam charge ratio between the foam sample run and the foil run:

QS/QF= (NCS/ ACS) /(NCF/ACF).

We can use this to relate the Au K X-ray scatters from the Au flecks to those from the foil:

NKS/NKF =

(QS/QF)(MAu/MAuF)(d/d)K(ES)/(d/d)K(EF)

where MAuF is the mass of gold foil included in the scan and the

differential cross-sections are evaluated at the mean proton energies ES, EF in the sample and foil respectively.

We find MAu = 3.2 0.4 g

Page 20: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

NLS/NLF =

((QS/QF)(MAu/MAuF)(d/d)L(ES)/(d/d)L(EF)

exp((-/)SAul) / exp((-/)SAu (tF/2))

From this, using the gold mass MAu = 3.2 0.4 g, we can find a

characteristic attenuation length l for X-rays in gold. This can be related to the gold diameter D, using an expression derived by Dirac, for the mean chord length in any one direction in a sphere:

D = 3 l

We find D = 5.5 0.6 m

For the L X-rays:

Page 21: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

• An alternative technique is to measure the mass of gold flecks in foam is X-ray-fluorescence using a rhodium target x-ray tube. However this can only produce L X-rays from Au, eliminating the technique as a candidate for measuring 5 m diameter flecks.

• So, to check our technique, we did measurements on a foam sample containing a similar mass of gold but having fleck diameters of ~0.5 ms.

• In these flecks L X-ray attenuation is of order 1%.• From XRF measurements the gold mass is:

MAu = 4.1 0.8 g• From our K X-ray measurements we find:

MAu = 3.8 0.7 g• From our L X-ray measurements we find:

MAu = 4.4 0.5 gAll three measurements are compatible.

Page 22: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

• Another interesting feature of the measurement on the 0.5 m flecks is the BS spectrum – which, at the high backscatter end, looks like one you would expect from a low density gold film.

Page 23: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough

Estimate of mass from RBS Measurements

Because of energy loss in the polyimide sleeve the gold backscatter spectrum above the Oxygen edge is representative of only a fraction of the cylinder area.

From this though we can calculate the gold density. Assuming a uniform distribution of the gold we can then infer the mass by multiplying by the volume. It is 50.5 g.

Page 24: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough
Page 25: Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough