Page 1: InvisiFence User Manual - Applied Infrared€¦ · 6. Detection Pattern ... an invisible perimeter fence around the secured area. The system recognizes threats whenever fluctuations

SensoGuard – vital protection | Haharuv 1, Modi'in Region Industrial Park, Shoham

Tel: 972-77-3012687 | Fax: 072-2221339 | Email: [email protected]

InvisiFence User Manual

Version 1.2

Date May 2016

Page 2: InvisiFence User Manual - Applied Infrared€¦ · 6. Detection Pattern ... an invisible perimeter fence around the secured area. The system recognizes threats whenever fluctuations

SensoGuard – vital protection | Haharuv 1, Modi'in Region Industrial Park, Shoham

Tel: 972-77-3012687 | Fax: 072-2221339 | Email: [email protected]

Table of Contents

1. Introduction ....................................................................................................................... 3

2. General .............................................................................................................................. 3

3. System Components .......................................................................................................... 4

4. Hierarchy of system components ...................................................................................... 6

5. Processing unit Connections ............................................................................................. 7

6. Detection Pattern .............................................................................................................. 8

7. System Installation ............................................................................................................ 9

8. Sensitivity Test ................................................................................................................. 11

9. SensoGuard Command and Control software ................................................................. 12

10. Specifications ................................................................................................................... 13

Page 3: InvisiFence User Manual - Applied Infrared€¦ · 6. Detection Pattern ... an invisible perimeter fence around the secured area. The system recognizes threats whenever fluctuations

SensoGuard – vital protection | Haharuv 1, Modi'in Region Industrial Park, Shoham

Tel: 972-77-3012687 | Fax: 072-2221339 | Email: [email protected]

1. Introduction SensoGuard Develop advanced intrusion detection systems for a broad range of applications. SensoGuard Team composed of engineers with more than 10 years of experience in development of intrusion detection systems based on seismic technology for both civil and military use.

Contact information:

Website: www.sensoguard.com

E-mail: [email protected]

Phone number: 972-77-3012687

2. General InvisiFence Security System provides a comprehensive solution for perimeter

protection.

InvisiFence operates with seismic sensors which are installed below ground, creating

an invisible perimeter fence around the secured area.

The system recognizes threats whenever fluctuations are sensed in its vicinity and sends

an early warning before the intrusion actually occurs.

The InvisiFence is designed to provide the optimal solution for protection of perimeters,

borders, prisons and large infrastructure sites.

Page 4: InvisiFence User Manual - Applied Infrared€¦ · 6. Detection Pattern ... an invisible perimeter fence around the secured area. The system recognizes threats whenever fluctuations

SensoGuard – vital protection | Haharuv 1, Modi'in Region Industrial Park, Shoham

Tel: 972-77-3012687 | Fax: 072-2221339 | Email: [email protected]

3. System Components

Seismic sensors- the seismic sensors sense very small ground vibrations. They transform vibration to electrical outputs. We analyze those vibration signals to detect intruders

Communication cables - the communication cables connects all of the processing units of the system to the hub. All of the units get the power supply and the RS485 data through this cable

Processing units – the processing unit can analyze a signal from 3 seismic sensors. The processing unit analyzes the data on real time and outputs the processing result to the RS485 line

Page 5: InvisiFence User Manual - Applied Infrared€¦ · 6. Detection Pattern ... an invisible perimeter fence around the secured area. The system recognizes threats whenever fluctuations

SensoGuard – vital protection | Haharuv 1, Modi'in Region Industrial Park, Shoham

Tel: 972-77-3012687 | Fax: 072-2221339 | Email: [email protected]

Hub units – a hub unit can manage a line of 600m of InvisiFence processing units. The hub outputs the alerts to the user via C&C program (contact SensoGuard to get more info about our C&C program) or through dry contacts or serial communication in SensoGuard protocol (if required, we can adjust our messages to a client request).

Page 6: InvisiFence User Manual - Applied Infrared€¦ · 6. Detection Pattern ... an invisible perimeter fence around the secured area. The system recognizes threats whenever fluctuations

SensoGuard – vital protection | Haharuv 1, Modi'in Region Industrial Park, Shoham

Tel: 972-77-3012687 | Fax: 072-2221339 | Email: [email protected]

4. Hierarchy of system components Every 3 seismic sensors are connected to a processing unit. Every processing unit analyzes the signals of those sensors and decides whether the signal is environmental noise or an event (footsteps, vehicle, digging). The hub collects the processing units outputs and sends the alerts to C&C computer or GSM modem. A hub is required every 600m approx. Data Flow of InvisiFence

Page 7: InvisiFence User Manual - Applied Infrared€¦ · 6. Detection Pattern ... an invisible perimeter fence around the secured area. The system recognizes threats whenever fluctuations

SensoGuard – vital protection | Haharuv 1, Modi'in Region Industrial Park, Shoham

Tel: 972-77-3012687 | Fax: 072-2221339 | Email: [email protected]

5. Processing unit Connections 6. Connector 1-3 Marked “Ch1-Ch3”: Connection of the seismic sensors channels 7. Connector 4 Marked “COM”: Configuration connection to PC using RS232 protocol 8. Connector 5-6 Marked Network In, Network Out: network connection using RS485

and power input

Connect the cable connector to the panel connector (red dots face each other), you should hear a “click” when the connector is properly connected to the unit panel. Connect all the connectors only after deployed all the sensors – it is crucial to keep the rubber cover on the connectors at all time – remove them only when you connect the connectors to the processing unit (put them back on when you open the connector)

Make sure you connect the sensors to the correct processing unit – the first unit in the line is unit 1, the second unit is unit 2 and so on. It is important to the HUB unit that the processing units will be in the right order

Page 8: InvisiFence User Manual - Applied Infrared€¦ · 6. Detection Pattern ... an invisible perimeter fence around the secured area. The system recognizes threats whenever fluctuations

SensoGuard – vital protection | Haharuv 1, Modi'in Region Industrial Park, Shoham

Tel: 972-77-3012687 | Fax: 072-2221339 | Email: [email protected]

6. Detection Pattern The seismic sensor has ball shaped detection pattern. Each sensor creates a ball shaped detection area around itself and detects every operation in this ball shaped zone.

Sensor detection area

InvisiFence system detection area

Page 9: InvisiFence User Manual - Applied Infrared€¦ · 6. Detection Pattern ... an invisible perimeter fence around the secured area. The system recognizes threats whenever fluctuations

SensoGuard – vital protection | Haharuv 1, Modi'in Region Industrial Park, Shoham

Tel: 972-77-3012687 | Fax: 072-2221339 | Email: [email protected]

7. System Installation

In terms of maintenance it is recommended to use inspection chambers for the processing

units (those chambers can be with open bottom, as for the processing units are water sealed IP67 rating

Preparing a trench: Dig a trench at the location of the InvisiFence system. Trench dimensions:

Width=10-30cm

Depth= 40cm Dig to 50cm at the locations of the sensors to be placed.

(If possible, it is best to dig the whole trench to 50 cm depth)

Page 10: InvisiFence User Manual - Applied Infrared€¦ · 6. Detection Pattern ... an invisible perimeter fence around the secured area. The system recognizes threats whenever fluctuations

SensoGuard – vital protection | Haharuv 1, Modi'in Region Industrial Park, Shoham

Tel: 972-77-3012687 | Fax: 072-2221339 | Email: [email protected]

Seismic sensor placement

Fix the sensor at the bottom of the trench (at the proper location – default distance is 6 meters between sensors)). Make sure that the sensor is straight – as shown below

Make sure that the sensor stuck well in the ground and doesn’t move

Cover the sensor gently with soil without stones and tighten lightly - so that the sensor will not move or change his angle

Page 11: InvisiFence User Manual - Applied Infrared€¦ · 6. Detection Pattern ... an invisible perimeter fence around the secured area. The system recognizes threats whenever fluctuations

SensoGuard – vital protection | Haharuv 1, Modi'in Region Industrial Park, Shoham

Tel: 972-77-3012687 | Fax: 072-2221339 | Email: [email protected]

Cover the communication cables with soil without stones so that the cables will not move, and be protected from big stones or rocks

8. Sensitivity Test After finishing deploying all the sensors and connecting them in the right order to the processing units and connect all the processing units to the HUB unit – you can start the sensitivity test

1. Set the sensitivity to level 1

Move 20 meters from the sensors line

Wait for 30 sec

Make sure there is no movement in the area

Walk across the sensors line between sensors 1.1 and 1.2 Check the C&C software for an event + hear the beeping sound from the processing unit If you got an event in the C&C repeat those steps between sensors every two sensors along the sensors line. In case you don't see an event in the C&C software set the sensitivity level to 2 and repeat the test between the 2 sensors. In case you don't see an event in the C&C software set the sensitivity level one level up and check again until you receive an event in the C&C software After finishing checking the intruder event along the whole sensors line, repeat those steps for Car event (only if necessary) It is possible to set different sensitivity for each event on each processing unit

Page 12: InvisiFence User Manual - Applied Infrared€¦ · 6. Detection Pattern ... an invisible perimeter fence around the secured area. The system recognizes threats whenever fluctuations

SensoGuard – vital protection | Haharuv 1, Modi'in Region Industrial Park, Shoham

Tel: 972-77-3012687 | Fax: 072-2221339 | Email: [email protected]

9. SensoGuard Command and Control software The InvisiFence system outputs alert data in the following options:

Dry contacts connection

Serial communication (RS232 or RS485)

RF transmission

GSM- via SMS messages

SensoGuard command and control software

The SensoGuard command and control software provides graphical user interface which includes a map view of the system installation area, and enable the operator a more convenient, user friendly way to respond to system alerts.

The software includes a list of the installed processing units and hub on the field, a map view of the installed units.

When the system detects an intruder, a siren sound can be played (configurable setting) and the operator can see immediately an icon in the relevant location in the map and also the alarm data in the event log.

Page 13: InvisiFence User Manual - Applied Infrared€¦ · 6. Detection Pattern ... an invisible perimeter fence around the secured area. The system recognizes threats whenever fluctuations

SensoGuard – vital protection | Haharuv 1, Modi'in Region Industrial Park, Shoham

Tel: 972-77-3012687 | Fax: 072-2221339 | Email: [email protected]

10. Specifications Invisible alert system based on seismic detectors

Can operate independently or integrated with existing systems

Working Temperature : -40 to 70 degrees (Celsius)

Relative humidity = 95%

Maintenance free, easy operation (plug & play)

Recommended installation depth below ground level: 4m

Underground detection depth: up to 20m

RoHS compliant

Operating Radius per sensor(depending on the area's terrain):

o Walking- up to 12m radius

o Digging- up to 20m radius

Outputs : RS232,RS485,Relay outputs

Case Enclosure: IP67, Polycarbonate

System indications

Intruder Detected

Sensor failure

Low battery

System OK message- Built in Test