introduction of gas metrology at nmijnmijclub/gas/docimgs/a1-01_introduction_gas... · 2. contents...
TRANSCRIPT
1
Introduction of Gas metrology at NMIJ
8th GAS CRM Workshopat NMIJ, Tsukuba, Japan 2010
June 9th -11th 2010
K. Kato
NMIJ, Japan
NMIJ
2
Contents of the presentation
• Introduction of NMIJ/AIST• Gas Lab in NMIJ• Metrology system in Japan• Gas Metrology in Japan• Future plan in NMIJ
3Josephson voltage standard
Optical frequency comb Cesium atomic beam frequency standardLight detector at ultra low temp.
Water triple point cellKilogram prototypeReference materials
Introduction of NMIJ/AIST
Quantum hall resister
m cdS
KkgAmol
6
I. Organization of AIST (3)
Metrology Planning Office
Metrology Quality Office
Reference Material Office
International Metrology Office
Metrology Training Center
7
6/10/2010
NMIJ (300, 200)
I. Organization of NMIJ/AIST (June 1st 2010)
Metrology Planning Office, Metrology Quality Office, Reference Material Office, International Metrology Office, Metrology Training Center
Time & Frequency, Length & Dimension, Mechanical, Acoustic & Vibration, Temperature & Humidity, Fluid Flow,
Material Properties & Metrological Statistics, Electricity & Magnetism, Photometry & Radiometry, Quantum radiation
Inorganic analytical chemistry division
Organic analytical chemistry division
Materials characterization division
Inorganic Standards Section (8+7)Environmental Standards Section (5+2)
Organic standard section 1 (6+3)Organic standard section 2 (5+8)Bio-medical standard section (9+3)
Surface and Thin Film section (10+4)Nanopore Standard Section (7+2)Polymer film and Semiconductor Section (6+8)
MIJ (260, 160)
Legal Metrology, Dissemination Technology
Measurement Standards System division (9+7) Total:69+45
8
標準ガス調製用高精度天秤(developed by NMIJ)
Gas Lab in NMIJDr. Kenji Kato Section Leader
Dr. Takuya Shimosaka Oxygen, Zero gases, water, FTIR,
GCs, Laser spectroscopy, .
Dr. Takuro Watanabe VOC, Methane, Propane, etc., GCs
Dr. Nobuhiro Matsumoto CO, CO2, NO, SO2, GCs, balance
Dr. Yuko Kitamaki Sulfur in fuels, LC, GC/MS
Dr. Nobuyuki Aoiki Green House gases, Formaldehyde,
Dynamic generation, GC/MS.
Chisato Nakata Technical staff
Kaoru Kato Technical staff
Yoko Mizuno Technical staff
9
Metrology system in Japan• JCSS : Japan Calibration Service System
Based on the Japan Metrology Law.CERI is a designated calibration bodyHigh purity materials from NMIJSupplied by commercial companies Quality system comply with ISO/IEC 17025 and ISO Guide 34
• NMIJ CRMNMIJ was established in 2001 and Gas Lab arose.Produced and certified by NMIJSI traceability by primary methodsQuality system based on ISO Guide-34 and ISO/IEC 17025Peer review by NMI experts, accredited by AS-NITEParticipation in CIPM international comparison
10
End users (Inspection lab, calibration lab)
SI
NMIJ CRMs
High purity, solution, gases, environmental materiasl, industrial materiasl (soil, water, food, metals, ceramic, oils, environmental, materials, pesticides)
JCSS NMIJ CRMNMIJ
Metrology System of Reference Materials in Japan
外部機関標準物質公表制度(SIトレサ)
臨床関連(14種)
「標準物質開発・供給システム」の研究
農薬(ポジティブリスト)等、多種類
標準物質、試薬メーカ-等の標準物質
Primary mixturesJCSS specified standards
CIPMKey comparisons
Primary high purity materials
(Gas and reagents makers)Secondary specified standards
[Accredited Calibration Bodies]
CIPMKey comparisons
[Designated Calibration Laboratory](CERI)
11
SI
Calibration & Evaluation : Environment, Soil, Water, Air, Indoor, Emission, etc.
High Purity Organic Chemicals (Solid/Liquid) High Purity Gas
Pure Materials as Traceability Sources
Standard Solution
Matrix Standard
Standard
Gases
Purity Analysis Technique and Gravimetric PreparationFreezing Point Depression
Method (Primary Method)
Calibration Standards
Accurate Balance developed by NMIJ
Adiabatic Calorimeter
developed by NMIJ or DSC
CRMs
JCSS Standards
CERI CRMs
Traceability Sources of JCSS from NMIJ
12
一部のJCSS基準物質含む
National Standard System in Japan
Total Number of JCSS standards and NMIJ CRMs
2nd 5 year term
1st 4 year term
2001 2002 2003 2004 2005 2006 2007 2008 2009
13
Traceability in JCSS
NMIJ
[Registered Calibration Bodies]
・Sumitomo Seika Chemicals Co., Ltd.
・ Japan fine products Inc.
・ Takachihho Chemical Industrial Co., Ltd.
・ Kawasaki Sogo gas center
Calibration
Calibration
Inspection[Registered Calibration Bodies]
・ Kanto Chemical Co., Inc.
・ Wako Pure Chemical Industry Ltd.
・ Nakarai Tesque Inc. (pH)
・ Kishida Chemicals Co., Ltd. (pH)
・ Katayama Chemical Inc. (pH)
[Designated Calibration Laboratory]
Chemical Evaluation and Research Institute (CERI)
SI
Primary Mixtures
Secondary Mixtures
Working Standards
High purity materials
Technical transfer
14
JCSS Inorganic solutions (metals, anions, pH)
Oxalate pH solution, pH 1.68Phthalate pH solution, pH 4.01
Natural phosphate pH solution, pH 6.86Phosphate pH solution, pH 7.41
Borate pH solution, pH 9.18Carbonate pH solution pH 10.01 JCSS 42 CRMs
15
JCSS Organic Solutions (1)
JCSS Solutions Concentration Development FY JCSS Solutions Concentration Development FY
Dichloromethane 100~1000 mg/L <2001 1,1-Dichloroethylene 100~1000 mg/L <2001
Benzene 100~1000 mg/L <2001 c-1,2-Dichloroethylene 100~1000 mg/L <2001
Toluene 100~1000 mg/L <2001 1,1,2-Trichloroethane 100~1000 mg/L <2001
1,2-Dichloroethane 100~1000 mg/L <2001 t-1,3-Dichloropropene 100~1000 mg/L <2001
Tetrachlorocarbon 100~1000 mg/L <2001 c-1,3-Dichloropropene 100~1000 mg/L <2001
Chroloform 100~1000 mg/L <2001 Tribromomethane 100~1000 mg/L 2001
Tetrachloroethylene 100~1000 mg/L <2001 Bromo-dichloromethane 100~1000 mg/L 2001
Trichloroethylene 100~1000 mg/L <2001 Dibromeo-chloromethane 100~1000 mg/L 2001
1,1,1-Trichlororoethane 100~1000 mg/L <2001 t-1,2-Dichloroethylene 100~1000 mg/L 2001
o-Xylene 100~1000 mg/L <2001 1,2-Dichloropropane 100~1000 mg/L 2001
m-Xylene 100~1000 mg/L <2001 1,4-Dichlorobenzene 100~1000 mg/L 2001
p-Xylene 100~1000 mg/L <2001 VOC 23 Mix 100~1000 mg/L 2004
16
JCSS Organic Solutions (2)
JCSS solutions Concentration Development FY JCSS solutions Concentration Development FY
Di-2-ethylehexyl-phthalate 1000 mg/L <2001 Bisphenol-A 1000 mg/L <2001
Di-n-bthyl-phthalate 1000 mg/L <2001 4-n-Nonyl phenol 1000 mg/L <2001
Diethyl-phthalate 1000 mg/L <2001 4-t-Octylphenol 1000 mg/L <2001
Butyle-benzyl-phthalate 1000 mg/L <2001 4-t-Buthylephenol 1000 mg/L <2001
Dipropyl-phthalate 1000 mg/L 2003 4-n-Heptylphenol 1000 mg/L <2001
Dipentyl-phthalate 1000 mg/L 2003 2,4-Dichlorophenol 1000 mg/L <2001
Dihexyl-phthalate 1000 mg/L 2003 Alkylphenol 6 Mix 1000 mg/L 2003
Dicyclehexyl-phthalate 1000 mg/L 2003
Phthalate 8 Mix 1000 mg/L 2003
JCSS solutions Concentration
U (k=2) /%
Formaldehyde 0.1 % 3.2
17
JCSS gasesGases Concentration range U (k=2) /%
CH4/Air 1 - 50 μmol/mol 1
C3H8/Air 3.5 - 500 μmol/mol 1
C3H8/N2 150 μmol/mol - 1.5% 1
CO/N2 3 μmol/mol - 15% 1.5 - 1
CO2/N2 3 μmol/mol - 16% 1
SO2/N2 0.1 μmol/mol - 1% 9 - 1
NO/N2 0.1 μmol/mol - 5% 4.5 - 1
NO2/N2 5 - 50 μmol/mol 5
O2/N2 0.9 – 25 %, 100 % 1
NH3/N2 20 - 100 μmol/mol 6
Gases Concentration range
U (k=2) /%
Chloroform 0.05- 100 μmol/mol
in N2
0.9 - 0.6
Dichloromethane 1.3 – 0.9
Tetrachloroethylene 1.0 – 1.5
Trichloroethylene 0.9 – 0.9
Benzene 1.8 – 0.5
1,2-dichloroethane 1.1 – 0.8
Vinyl Chloride 0.8 – 0.8
1,3-Butadiene 2.6 – 2.6
Acrylonitrile 2.4 – 2.4
BTXE/N2 (MIX) 0.002- 100 μmol/mol
in N2
1.7 – 0.8
Ethanol/N2 100 – 500 μmol/mol
0.9 – 0.6
Ethanol/Air 1.1 – 0.7
Gases Concentration range U (k=2) /%
OC 12MIX 1 μmol/mol Soil gases 1.0 – 2.2
VOC 7MIX 1 μmol/mol Sick house gases 1.0 – 1.8
Acetaldehyde 1 μmol/mol 4
Stylene 1 μmol/mol 1.8
18
National Standard System in Japan
JCSS 校正証明書発行件数の推移 (濃度)(NITE Web Site)
260,000
320,000
300,000
280,000
340,000
200,000
220,000
240,000
180,0002004 2005 200720032000 2001 2002 2006 2008
19
Number of NMIJ CRMs in July 2009 (131 CRMs).
CRM from NMIJ (NMIJ CRM)
Surface analysis by EPMP 18Industrial materials (metal, thin film,
polymer, ceramic) 19High purity inorganic materials 4High purity organic materials 17Organic solutions 12In vitro diagnostic 5
Polymers (molecular weight) 8Environmental materials 12Foods 6Chemical speciation 3Polymers (RoHS) 15Gases 12
Total 131
20
ome comments for consideration when composing the list of exceptions as referred to in the document on "Traceability in the CIPM MRA" (CIPM 2009-24)
by Robert Kaals, 23 March 2010• The CIPM document CIPM 2009-24 clarifies acceptable traceability routes for NMIs[1] wishing to publish CMCs in the KCDB. For an NMI traceability to the SI
has to be realized and delivered by the NMI itself or through the published CMCs of another NMI, or through the calibration and measurement services offered by the BIPM. An NMI cannot have it’s CMCs published if the metrological traceability of these claims is achieved via a non-NMI.
• In the scope of the CIPM MRA, being the top of the metrological pyramid, traceability obtained from a non-NMI, accredited or not, is not acceptable as the CIPM wishes to have the whole system under the full expert control of the participating NMIs and RMOs and the CIPM.
• Whenever possible the traceability should be to the SI, but where this is not yet feasible traceability to other internationally agreed references can be accepted, provided they have been proposed by the CC concerned, approved by the CIPM and published by the BIPM.
• On the highest top of the metrological pyramid primary realizations or representations of the measurement unit(s) concerned establish traceability to the SI. Potentially primary methods can only be considered as primary methods when the whole measurement procedure is fully understood and carefully and competently carried out.
• Certified reference materials for pure substances are used for calibration and to disseminate traceability for chemical analyses. The values assigned to the mass fraction content of pure substance reference materials are based on measurement capabilities for purity analysis.
• Consequently, for chemical analyses a crucial NMI activity is purity analysis of its pure material calibrators. This is most commonly done through a mass balance approach requiring the quantification of impurities in the material.
• In cases as described in point 6. the NMI has to declare itself as the source of traceability to the SI• .• If the NMI uses CRMs for establishing traceability obtained from another recognized NMI, having CMCs published in the KCDB that cover the value assignment
of this CRM, then the source of traceability is the other NMI.• Several NMIs published CMCs for purity analysis and can thus make reference to these CMCs. However, in a number of cases NMIs do not offer their purity
analysis capabilities as a service to external customers. So, these capabilities are not published as calibration and measurement capabilities in the KCDB. Therefore, when an NMI uses internal/in-house purity analysis capabilities it has to demonstrate its purity analysis competence, notably by: fully describing its measurement procedures within its quality documentation; achieving successful on-site peer review of these capabilities; and participating in relevant key comparisons for purity analysis if available.
• In the case of enriched isotopes or isotopic abundance standards delivered by an NMI not having published CMCs, traceability can be declared to this NMI under the condition that the NMI's competence in performing the measurement procedures which are the basis of the values of the standards has been demonstrated, notably by: fully describing its measurement procedures within its quality documentation; achieving successful on-site peer review of these capabilities; and participating in relevant key comparisons if available..
• In exceptional cases where there is no NMI that delivers these isotope CRMs and these isotope CRMs are available only from non-NMIs, the NMI using these isotopes has to demonstrate that the laboratory delivering the isotope CRMs is competent and complies with quality assurance criteria as formulated in ISO/IEC 17025 under the chapter of "sub-contracting". See also the CIPM document on "Subcontracting of measurements under the CIPM MRA", CIPM 2005/09. This means that the subcontracting NMI has to have its sub-contracting process fully described in its quality manual in conformity with ISO/IEC 17025 and ISO Guide 34, while the sub-contractor needs to have a quality system in place in compliance with ISO/IEC 17025 and ISO Guide 34.
• For some type of analysis one likes to apply NAA or NMR methods. As these capabilities require costly facilities and many NMIs do not possess these capabilities, it is permitted to sub-contract these measurements to another competent institute. Like in point 11. the sub-contracting NMI has to ensure that the sub-contractor is competent and has a quality system in place in compliance with ISO/IEC 17025/ISOGuide 34.Results of measurements obtained by sub-contractors should have added-value and be in addition to own in-house measurement competence and capabilities in the field concerned. The NMI cannot claim CMCs based on the capabilities of sub-contractors.
• Traceability is not established through the results of a Key or Supplementary Comparison nor by the results obtained in a PT scheme.•
[1] NMI refers to both National Metrology Institutes and Designated Institutes
21
ome comments for consideration when composing the list of exceptions as referred to in the document on "Traceability in the CIPM MRA" (CIPM 2009-24)
by Robert Kaals, 23 March 2010
• The CIPM document CIPM 2009-24 clarifies acceptable traceability routes for NMIs[1] wishing to publish CMCs in the KCDB. For an NMI traceability to the SI has to be realized and delivered by the NMI itself or through the published CMCs of another NMI, or through the calibration and measurement services offered by the BIPM. An NMI cannot have it’s CMCs published if the metrological traceability of these claims is achieved via a non-NMI.
• In the scope of the CIPM MRA, being the top of the metrological pyramid, traceability obtained from a non-NMI, accredited or not, is not acceptable as the CIPM wishes to have the whole system under the full expert control of the participating NMIs and RMOs and the CIPM.
22
Achievements in the Recent 5 Years • Development of high purity gases for JCSS
Quality system for productionAnalytical methods of purity (GC, FTIR, ..)
• Improvements in precision of gravimetric preparationOptimization of weighingKnowledge of surface and adsorption
• Analytical technique for water measurementDew point meter and CRDS
• Participation in CIPM comparisons
23
High purity gas CRMsStandard gas name Components Purity, U(k=2) Year (FY)NMIJ CRM 3401 Nitrogen monoxide,
NO99.95±0.05% 2002
NMIJ CRM 3402 Sulfur dioxide, SO2 >99.998% 2003, 2009
NMIJ CRM 4051 Methane, CH4 99.9999±0.0001% 2005, 2009
NMIJ CRM 4052 Propane, C3H8 99.99±0.01% 2005NMIJ CRM 4041 Vinyl chloride, 100.0±0.1% 2005NMIJ CRM 3407 Carbon dioxide, CO2 99.99951±0.00036% 2006
NMIJ CRM 3404 Oxygen, O2 99.99993±0.00009% 2006, 2008
NMIJ CRM 4042 1,3-butadiene 99.7±0.6% 2006High purity Carbon monoxide, CO 99.9965±0.0004% 2008High purity Ammonia, NH3 (2012-)Zero gases N2 , Air (2010-13)
CRMs developed in 2006 - 2009
24
NMIJ CRMs (Gas Mixtures)
Standard gas name Components Year (FY)NMIJ CRM 4401 p-Xylene, cis-1,2-Dichloroethylene, 1,1,1-
Trichloroethane / N2, 1 umol/mol2003
NMIJ CRM 4402 cis-1,2-Dichloroethylene, 1,1,1-Trichloroethane / N2, 100 nmol/mol
2003
NMIJ CRM 4403 SF6 ,CF4 / N2, 100 umol/mol 2004NMIJ CRM 4404 SF6 ,CF4 / N2, 5000 umol/mol 2007NMIJ CRM 4405 C2F6 ,CF4 / N2, 5000 umol/mol 2007NMIJ CRM 440X SF6 , C2F6 ,CF4 / N2, 5000 umol/mol 2009NMIJ CRM 440X NF3, C2F6 ,CF4 / N2, 5000 umol/mol 2010-NMIJ CRM 3403 N2O / N2, 200 - 300 umol/mol 2004
Sulfur / N2 H2S, DMS, DES / N2 , 300 nmol/mol PlanningOxygen O2 / N2 Low concentration Planning
Green house gases N2O/N2, CO2/N2, CH4 / N2 PlanningHydrocarbons, Natural gases C2 - C6 / N2 , CH4, C3H8, CO2, N2 etc. Planning
Sick house gases Formaldehyde Planning
25
Methane (6N) 4 impurities
( at 1 - 5 μmol/mol) in 47L AL cylinder12.3 MPa (6000 L)
ParticipantsKRISS, NIM, NMIA, NMISA, NMIJ, BAM, NIST, NPL, VSL, VNIIM
Impurity analysis
Scheme of international comparison CCQM-K66Purity analysis of high purity methane
Homogeneity Test
Pilot lab
Purity analysis
Subsection
Up to ten 3L AL cylinders
>5 MPa (150 L)
Sample Task
Cylinder delivery
Cylinder return
Draft-A
Reporting
2nd Instability test
1st Instability test
Aug. 9 2008
Mar. 31 2008
Mar. 31 2008
2008 Nov. – 2009 Apr.
(one to two months)
(End of June 2009)
(two months)
(one month)
(Dec. 2009)
26
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
345 350 355 360 365 370 375 380 385
Gravimetric values reported by the participants / (μmol/mol)Res
idue
of X
-axi
s/
(μm
ol/m
ol)
Optimization of Gravimetric Method(In the Case of CCQM-P41 Sample)
0.4 μmol/molOur resultsfor CCQM-P41
Revised value
Results of NMIJ for CCQM-P41 deviated about 0.4 mmol/mol from KCRV.After optimization our sample was reanalyzed by NMIJ and the deviation
evaluated became smaller than the uncertainty of calibration gas.
CCQM and APMP Comparisons before 2006
27
GAS Key nnumber Year Status Pilot Lab Participant
CO in N2 CCQM-K01a 98 finished NMi CERI
CO2 in N2 CCQM-K01b 98 finished NMi CERI
NO in N2 CCQM-K01c 98 finished NMi CERI
SO2 in N2 CCQM-K01d 98 finished NMi CERI
Natural gas I CCQM-K01e 98 finished NMi CERI
Natural gas II CCQM-K01f 98 finished NMi CERI
Natural gas III CCQM-K01g 98 finished NMi CERI
Automotive emission: CO, CO2 and C3H8/N2 CCQM-K03 98 finished NMi-VSL CERI
Ethanol in air CCQM-K04 99-00 finished NPL CERI
Ethanol in air APMP.QM-K04 00-01 finished NMIJ CERI
Automotive emission: CO, CO2 and C3H8/N2 APMP.QM-K03 00-01 finished KRISS CERI
Gravimetric blending, CO/N2 CCQM-P23 00-01 finished NMi CERI
BTX/N2 CCQM-K07 99-00 finished NIST NMIJ
Benzene, Toluene, and Xylene in Air CCQM-K10 01 finished NIST NMIJ
Natural gas type V CCQM-K16,b, CCQM-P49 01 finished BAM,NMi NMIJ
CO2 + CH4/Air CCQM-P41 02 finished NMi-VSL NMIJ
SF6 and CFCs in Nitrogen CCQM-K15, CCQM-P51 02 finished KRISS NMIJ
VOCs CCQM-K22, CCQM-P71 02-03 finished NMIJ CERI
Natural gasⅡ CCQM-K23b 04-05 finished NMi-VSL NMIJ
NO at ambient level CCQM-K26a 04 finished NPL CERI
SO2 at ambient level CCQM-K26b 04-05 finished NPL CERI
CCQM and APMP Comparisons before 2006
28
GAS Key nnumber Year Status Pilot Lab Participant
Gravimetric blending, n-C6H14/CH4 CCQM-K54 05-06 finished NMi-VSL NMIJ
Gravimetric blending, NO/N2 CCQM-P73 06-07 finished NMi CERI
Gravimetric blending, N2/He APMP.QM-S1 05-06 finished KRISS NMIJ
ammonia in N2 CCQM-K46 06-07 draft-B NMi CERI
CO in N2 CCQM-K51 07-08 finished NMISA CERI, NMIJ
CO2 in N2 CCQM-K52 07 finished NMi-VSL, NMISA NMIJ
O2 in N2 CCQM-K53 06-07 finished KRISS NMIJ
Ethanol in air APMP.QM-K4.1 05-07 finished CERI CERI
Ambient ozone CCQM-P28 05 finished BIPM NIES
SO2 in N2 APMP.QM-K1d 05-07 finished CERI CERI
Purity analysis (Methane) CCQM-K66 08-09 running NMIJ NMIJ
N2O ambient Level CCQM-K68 08-09 draft-A KRISS NMIJ
Synthetic natural gas CCQM-P87 07-07 finished NPL NMIJ
O2 ambient Level APMP.QM-S2 08-09 draft-A NMIJ NMIJ
NO2 in nitrogen CCQM-K74/P110 09-10 running BIPM NMIJ
SO2/N2, 100 μmol/mol CCQM-Kxx 09-10 running NIST CERI
Dynamic standards in ppb range CCQM-Pxx 10-11 planning METAS NMIJ
O2/N2 at 5 μmol/mol CCQM-Kxx 10-11 planning NIM NMIJ
29
Future Plan in NMIJ• High purity gases
Traceability source for JCSSZero gases
• Green house gasesCFCs, NF3, CO2, N2O, CH4
• Dynamic generationFormaldehyde
• Analytical methodsSpectroscopic methods (FT-IR, Laser)
• Clean energySulfur, DMS,…
30
NMIJ CRM 3403-a and NMIJ CRM 4403-a
• SI traceability by primary methods• Quality system ISO Guide-34
Participation to International Comparisons
CCQM-K15(SF6, CF4), emission level 2003-2004
CCQM-P41(CO2,CH4), ambient level 2002-2003
NMIJ CRM 3403-a : N2O/N2 (280ppm +/- 1.9ppm)
NMIJ CRM 4403-a : SF6 + CF4/N2 (100ppm +/- 0.5ppm)
NMIJ CRM 4404-a : SF6 + CF4/N2 (~5000ppm)
NMIJ CRM 4405-a : CF4+C2F6/N2 (~5000ppm)
NMIJ CRM 4406-a : CF4+C2F6+SF6 /N2 (~5000ppm)
NMIJ CRM 440x-a : NF3/N2 (~5000ppm)Compounds GWPCO2 1CH4 23N2O 296CFCs 4000-10000Halon1301 5,600HCFCs 100-10000CF4 6,300C2F6 12,500CCl4 1,400SF6 22,200
Dynamic Generation of Formaldehyde Primary Reference
• Traceable to SI• Concentration range 10 ppb - ppm• Uncertainty < 2 – 3 %
Technical issues• Permeation device and balance• Analysis of formaldehyde at ppb level• Impurities in reference gases• Handling of formaldehyde gas
Target
Balance
• Real time monitoring of permeation rate• Isolation between balance and gas flow • Zero adjustment during measurement
BalanceBalance Magnetic
suspension balance(Rubotherm)
Resolution 10 μgCapacity 30 gTemp. range -40℃~50℃Temp. precision ±0.1℃
Dilution gas
Water in
Dilution gas
Permeation device
Gas output
33
Sulfur standards in Liquid Fuels and Liquefied Gases
• NMIJ CRM 4215-a
Sulfur in toluene 0.98+/-0.02 mg/kg
• NMIJ RM 4216-a (New)
Sulfur in toluene (Blank) 19+/-5 ug/kg
• NMIJ CRM 421X 50 ug/kg (planned)
Slulfur in toluene (low concentration)
• .
35
CRM No. Certified Value(Purity)in%
1 Ethanol NIMC CRM 4001-a 99.895±0.0502 Benzene NMIJ CRM 4002-a 99.992 ±0.003 *3 Toluene NIMC CRM 4003-a 99.984±0.013 *4 1,2-Dichlorethane NIMC CRM 4004-a 99.97 ±0.025 Dichloromethane 99.95 ±0.056 Carbon tetrachloride 99.99 ±0.017 Chloroform 99.91 ±0.098 Tetrachloroethylene 99.95 ±0.059 Trichloroethylene 99.87 ±0.13
10 1,1,1-trichioroethane 99.98 ±0.0211 o-xylene NMIJ CRM 4011-a 99.933 ±0.002 *12 m-xylene NMIJ CRM 4012-a 99.84 ±0.1613 p-xylene 99.82 ±0.1814 1,1-dichloroethylene 99.92 ±0.0815 cis-1,2-dichoroethylene 99.39 ±0.5816 1,1,2-trichoroethane 99.94 ±0.0617 trans-1,3-dichloropropane 98.44 ±1.4918 cis-1,3-dichloropropane 99.59 ±0.4019 Ethyl Benzene NMIJ CRM 4021-a 99.88 ±0.0320 1,3-butadiene 99.50 ±0.29 GC21 Acrylonitrile NMIJ CRM 4040-a 99.97 ± 0.0122 Vinylchloride 99.99 ±0.06 GC
Reference Material
List of High Purity VOCs